Professional Documents
Culture Documents
Catalogue September
06
Flexibility
b
Ingenuity
Auto-adapts to its environment, "plug & play" b Application functions, control, communication and diagnostics embedded in the products b User-friendly operation either directly on the product or remotely
b
Simplicity
b Cost effective optimum offers that make selection easy for most typical applications b Products that are easy to understand for users, electricians and automation specialists b User-friendly intuitive programming
Interchangeable modular functions, to better meet the requirements for extensions b Software and accessories common to multiple product families This international site allows you to access all the Telemecanique products in just 2 clicks via comprehensive range data-sheets, with direct links to: b Complete library: technical documents, catalogs, certificates, FAQs, brochures... b Selection guides from the e-catalog. b Product discovery sites and their Flash animations. You will also find illustrated overviews, news to which you can subscribe, a discussion forum, the list of country contacts... To live automation solutions every day!
Compactness
b
Openness
b Compliance with field bus, connection, and software standards b Enabling decentralised or remote surveillance via the web with Transparent Ready products
Contents
Thermal-magnetic circuit-breakers
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2 and 3 b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 6 and 7 b Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 8 to 13 b Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 24 to 36 b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 46 to 51 b Dimensions, mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 66 to 71 b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 72 and 73
Magnetic circuit-breakers
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 4 and 5 b Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 14 to 17 b Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 37 to 45 b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 52 and 53 b Dimensions, mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 74 to 76 b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 77
Enclosed circuit-breakers
b References, dimensions, mounting . . . . . . . . . . . . . . . . . . . . . . . . pages 78 to 85
Substitution table
b Old / new references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 86
Selection guide
Applications
13 In
Up to 15 kW
Up to 30 kW
37 kW
0.132 A
965 A
5680 A
10100 kA
35100 kA
50100 kA
15 kA
Without
With
Without
Without
Circuit-breaker type
GV2 ME
GV2 P
GV3 P
GV3 ME80
Pages
46 and 47
48
48
48
20 In
7.5110 kW
Up to 11 kW
12220 A
0.2523 A
35 and 36 kA
70 kA
15100 kA
With
With
GV7 RE
GV7 RS
GV2 RT
49
50 and 51
Selection guide
Applications
Protection of motors Magnetic circuit-breakers provide short-circuit protection. They must be combined with thermal overload relays to provide motor overload protection.
13 In
Up to 15 kW
0.432 A
10100 kA
35100 kA
With
Circuit-breaker type
GV2 LE
GV2 L
Pages
52
53
614 In
813 In
6.312.5 In
Up to 30 kW
37 kW
0.37250 kW
2565 A
80 A
1.5500 A
50100 kA
35 kA
35.7150 kA
45.7150 kA
Without
With
With
GV3 L
GK3 EF80
NS 80
NS 100 to NS 250
53
53
Presentation
533886
533887
Presentation
GV2 ME, GV2 P, GV3 ME, GV3 P and GV7 R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically designed for the control and protection of motors, conforming to standards IEC 60947-2 and IEC 60947-4-1. Connection GV2 GV2 ME and GV2 P circuit-breakers are designed for connection by screw clamp terminals. Circuit-breaker GV2 ME can be supplied with lugs or spring terminal connections. Spring terminal connections ensure secure, permanent and durable clamping that is resistant to harsh environments, vibration and impact and are even more effective when conductors without cable ends are used. Each connection can take two independent conductors. GV3 GV3 circuit-breakers feature connection by BTR screws (hexagon socket head), tightened using a n 4 Allen key. This type of connection uses the EverLink system with creep compensation (1) (Schneider Electric patent). This technique makes it possible to achieve accurate and durable tightening torque, in order to avoid cable creep. GV3 circuit-breakers are also available with connection by lugs. This type of connection meets the requirements of certain Asian markets and is suitable for applications subject to strong vibration, such as railway transport. GV7 GV7 circuit-breakers: with connection by screw clamp terminals (for bars and lugs) and by clip-on connectors. Operation Control is manual and local when the motor circuit-breaker is used on its own. Control is automatic and remote when it is associated with a contactor.
GV2 ME and GV3 ME80
1 2 4
GV2 ME with screw clamp terminals
1 2 4
510493
1 3 2 4
GV3 P
533888
1 3 2 4
GV2 P
Pushbutton control. Energisation is controlled manually by operating the Start button I 1. De-energisation is controlled manually by operating the Stop button O 2, or automatically by the thermal-magnetic protection elements or by a voltage trip attachment.
GV2 P, GV3 P and GV7 R
533890
b Control by rotary knob: for GV2 P and GV3 P b Control by rocker lever: for GV7 R. Energisation is controlled manually by moving the knob or rocker lever to position I 1. De-energisation is controlled manually by moving the knob or rocker lever to position O 2. De-energisation due to a fault automatically places the knob or rocker lever in the Trip position 3. Re-energisation is possible only after having returned the knob or rocker lever to position O.
(1) Creep: normal crushing phenomenon of copper conductors, that is accentuated over time. GV7 R
1 3 2
Characteristics: pages 8 to 23
References: pages 46 to 51
Dimensions: pages 66 to 71
Presentation (continued)
Presentation (continued)
Protection of motors and personnel Motor protection is provided by the thermal-magnetic protection elements incorporated in the motor circuit-breaker. The magnetic elements (short-circuit protection) have a non-adjustable tripping threshold, which is equal to 13 times the maximum setting current of the thermal trips. The thermal elements (overload protection) include automatic compensation for ambient temperature variations. The rated operational current of the motor is displayed by means of a graduated knob 4. Personnel protection is also provided. All live parts are protected against direct finger contact from the front panel. The addition of an undervoltage trip allows the circuit-breaker to be de-energised in the event of an undervoltage condition. The user is therefore protected against sudden starting of the machine when normal voltage is restored, since the Start button I has to be pressed to restart the motor. With the addition of a shunt trip, de-energisation of the unit can be remotely controlled. The operators on both open-mounted and enclosed motor circuit-breakers can be locked in the Stop position O by up to 4 padlocks. Because they are suitable for isolation, these circuit-breakers, in the open position, provide an adequate isolation distance and indicate the actual position of the moving contacts by the position of the operators.
Special features These motor circuit-breakers are easily installed in any configuration thanks to their universal fixing arrangement: screw fixing or clip-on mounting on symmetrical, asymmetrical or combination rails.
Characteristics: pages 8 to 23
References: pages 46 to 51
Dimensions: pages 66 to 71
Characteristics
Environment
Circuit-breaker type Conforming to standards GV2 ME GV2 P IEC 60947-1, 60947-2, 60947-4-1, EN 60204, UL 508, CSA C 22.2 n 14-05, NF C 63-650, 63-120, 79-130, VDE 0113, 0660 GV3 P IEC/EN 60947-1, 60947-2, 60947-4-1, UL 508 type E, CSA C 22.2 n 14-05 type E GV3 ME80 IEC/EN, NF EN, BS EN, DIN EN 60947-2, 60947-4-1 GV7 R IEC 60947-1, 60947-2, 60947-4-1, EN 60947-1, 60947-2, EN 60947-4-1, NF C 63-650, NF C 63-120, 79-130, VDE 0113, 0660 UL, DNV, CCC
Product certifications
Open mounted
UL, CSA, CCC, CEBEC, GOST, TSE, BV, GL, LROS , DNV, PTB, EZU, SETI, RINA, ATEX (pending) TH IP 20
UL (1), CSA, UL, CSA, CCC, PTB, EZU, GOST, GOST, TSE, ATEX (pending) DNV, LROS, GL, BV, RINA, CCC, ATEX (pending) TH IP 20
TC IP 20
In enclosure
Open mounted In enclosure Temperature compensation Open mounted In enclosure Flame resistance Conforming to IEC 60695-2-1 Maximum operating altitude Suitable for isolation Conforming to IEC 60947-1 7-1-6 Resistance to mechanical impact Sensitivity to phase failure
On: 15 gn -11 ms Off: 30 gn -11 ms 5 gn (5150 Hz) 5 gn (5300 Hz) - 40+ 80 - 40+ 80 - 40+ 80 - 20+ 60 - 20+ 60 - 20+ 60 (2) - 20+ 40 - 20+ 40 - 20+ 40 - 20+ 60 - 20+ 60 - 20+ 60 - 20+ 40 - 20+ 40 - 20+ 40 960 960 2000 3000 Yes Yes 0.5 0.5 0.5 In enclosure: IK 06 IK 09 Yes, conforming to IEC 60947-4-1 7-2-1-5-2 GV2 ME GV2 P GV2 RT GV3 P GV3 ME80 A AC-3 690 690 600 (B600) 50/60 6 8 30 000
22 gn - 20 ms 2.5 gn (025 Hz) - 40+ 80 - 20+ 60 - 20+ 40 - 20+ 60 - 20+ 40 960 3000 0.5
30 gn -11 ms 2.5 gn (25 Hz) - 55+ 95 - 25 + 70 - 25 + 55 (3) 960 2000 Yes 0.5
Technical characteristics
Circuit-breaker type GV7 Rp20... Rp100 A AC-3 690 750 600 50/60 8 5 50 000 8.7 40 000 14.5 20 000 GV7 Rp150 GV7 Rp220
Conforming to IEC 60947-2 Conforming to IEC 60947-4-1 Rated operational voltage Conforming to IEC 60947-2 (Ue) Rated insulation voltage Conforming to IEC 60947-2 (Ui) Conforming to CSA C22-2 n 14, UL 508 Rated operational Conforming to IEC 60947-2 frequency Rated impulse withstand Conforming to IEC 60947-2 voltage (U imp) Total power dissipated per pole Mechanical durability (C.O.: Close, Open) Electrical durability 440 V In/2 for AC-3 duty 440 V In Duty class (maximum operating rate) Maximum conventional Conforming to IEC 60947-4-1 rated thermal current (Ith) Rated duty Conforming to IEC 60947-4-1
Utilisation category
100 000 30 000 50 000 40 000 20 000 50 000 30 000 20 000 10 000 25 25 25 25 0.16 0.16 0.40 13 80 12 150 220 32 32 23 65 100 Continuous duty (1) UL 508 type E for GV2 PppH7 (2) Leave a space of 9 mm between 2 circuit-breakers: either an empty space, or side mounting addon contact blocks. Horizontal mounting is possible up to 40 C. (3) For operation up to 70 C, please consult your Regional Sales Office.
References: pages 46 to 51
Dimensions: pages 66 to 71
Characteristics (continued)
Mounting characteristics
Operating position Without derating, in relation to normal vertical mounting plane
90 90
90
90
Connection characteristics
Connection to screw clamp terminals or spring terminals
Bare cables
Circuit-breaker type Connection to screw clamp terminals (1) Solid cable (Max. number of conductors x c.s.a.) Flexible cable without cable end Flexible cable with cable end Tightening torque Connection to spring terminals Number of conductors x c.s.a. Solid cable Flexible cable without cable end
2 x 1.5 (2) 2 x 4
e
Circuit-breaker type Pitch Without spreaders With spreaders Bars or cables with lugs e L L d Screws Tightening torque Bare cables (copper or aluminium) with connectors Height (h) C.s.a. Tightening torque N.m mm mm2 N.m mm mm mm mm mm mm GV2 MEpp 6 13.5 y6 y 9.5 y 9.5 y 10 M4 1.7
L
GV3 Ppp6 17.5 y6 y 13.5 y 16.5 y 10 M6 6
L
GV7 Rp20...R p100 35 45 y6 y 25 y 10 M6 10 20 1.5...95 15
L'
GV7 R p150 35 45 y6 y 25 y 10 M8 15 20 1.5...95 15 GV7 R p220 35 45 y6 y 25 y 10 M8 15 20 1.5...185 15
(1) For motor circuit-breakers GV3 P: BTR hexagon socket head screws, EverLink system. Require use of an insulated Allen key, in compliance with local electrical wiring regulations. (2) For cross-sections 1 to 1.5 mm2 , the use of an LA9 D99 cable end reducer is recommended.
References: pages 46 to 51
Dimensions: pages 66 to 71
Characteristics
Rating
14
18
32
230/240 V
kA
g g
g g
g g
400/415 V
kA
g g
g g
g g
g g
g g
15 15 15 10 g 50 50 40 50 g
g g
g g
g g
g g
g g
50 50
50 50
50 50
440 V
kA
g g
g g
g g
50 15 8
g g
g g
g g
g g
50 75
20 75
20 75
20 75
100 100 50 50 50 50 g
500 V
kA
g g
g g
g g
50 10 6
g g
g g
g g
50
42
10 75
10 75
10 75
100 100 75 75 75 75 g
100 75
690 V
kA
g g
75 75 75 75 75 75 75 75 g
Associated fuses (if required) if Isc > breaking capacity Icu conforming to IEC 60947-2
230/240 V
aM gG
A A
g g
g g
g g
g g
g g
g g
g g
80
80 g
g g
g g
g g
g g
g g
g g
g g
g g
100 100 g
400/415 V
aM gG
A A
g g
g g
g g
g g
g g
63 63 80 80 g 80 80 100 100 g
g g
g g
g g
g g
g g
440 V
aM gG
A A
g g
g g
g g
50 50 50 50 63 63 g 63 63 63 63 80 80 g
g g
g g
g g
g g
50 63
63 80
80
80
100 100
500 V
aM gG
A A
g g
g g
g g
50 50 50 50 50 50 g 63 63 63 63 63 63 g
g g
g g
g g
50 63
50 63
50 63
50 63
50 63
690 V
aM gG
A A
g g
16 25 32 32 40 40 40 40 g 20 32 40 40 50 50 50 50 g
20 25 40 40 25 32 50 50
50 63
50 63
50 63
50 63
References: pages 46 to 51
Dimensions: pages 66 to 71
10
Characteristics (continued)
Breaking capacity of GV2 ME and GV2 P (used in association with current limiter GV1 L3)
Circuit-breaker type Rating A GV2 ME 01 to 06 07 0.1 to 2.5 1.6 g g kA g g kA g g kA g g g g g g g g g g 08 4 10 6.3 14 10 16 14 20 18 21 23 22 25 32 32
230/240 V
kA
g g g g g g g g
g g g g g g g g
g g g g g g 50 100
g g 100 50 50 75 42 100
g g 100 50 20 75 10 75
g g 100 40 20 75 10 75
g g 100 40 20 75 10 75
g g 100 40 20 75 10 75
400/415 V
440 V
500 V
08 4
10 6.3
14 10
16 14
20 18
21 23
22 25
32 32
230/240 V
kA
g g g g g g g g 50
g g g g g g g g 50
g g g g g g 100 50 50
g g g g 100 50 100 50 50
g g g g 100 50 100 50 50
g g g g 100 50 100 50 50
g g g g 100 50 100 50 50
g g g g 100 50 100 50 50
400/415 V
kA
g g
440 V
kA
g g
500 V
kA
g g
690 V (3)
Icu = Ics
kA
08 4
10 6.3
14 10
16 14
20 18
21 23
22 25
32 32
Cable protection against thermal stress in the event of short-circuit (PVC insulated copper cables)
p p p p
y 10 kA y 6 kA (2) y 20 kA y 10 kA (2) p p p p p p
(2) (2) p p
(2) (2) p p
(2) (2) p p
References: pages 46 to 51
Dimensions: pages 66 to 71
11
Characteristics
230/240 V
kA
100 100
100 100 50 50 50 50 10 50 5 60
100 100 50 50 50 50 10 50 5 60
100 100 50 50 50 50 10 50 5 60
400/415 V
kA
100 50
440 V
kA
50 50
500 V
kA
12 50
690 V
kA
6 50
230/240 V
aM gG
A A A A A A A A A A
g g g g 63 80 63 80 50 63
g g g g 80 100 63 80 50 63
g g g g 125 160 63 80 50 63
g g g g 125 160 63 80 50 63
415 V
aM gG
440 V
aM gG
500 V
aM gG
690 V
aM gG
g Fuse not required: breaking capacity Icn > Isc. (1) As % of Icu.
References: pages 46 to 51
Dimensions: page 69
12
Characteristics
230/240 V
kA
85 100
400/415 V
kA
36 100
440 V
kA
36 100
500 V
kA
18 100
690 V
kA
8 100
Cable protection against thermal stress in the event of short-circuit (PVC insulated copper cables)
y 6 kA p p
y 6 kA y 25 kA p
(2) (2) p
(2) (2) p
(2) (2) p
(2) (2) p
(1) As % of Icu. p Cable c.s.a. protected. (2) Cable c.s.a. not protected.
References: pages 46 to 51
Dimensions: pages 66 to 71
13
Characteristics
Environment
Circuit-breaker type Conforming to standards Product certifications Protective treatment Shock resistance Vibration resistance Ambient air temperature Conforming to IEC 60068-2-27 Conforming to IEC 60068-2-6 Storage Operation Flame resistance Maximum operating altitude Operating position Conforming to IEC 60695-2-1 C C C m GV2 LE GV2 L IEC 60947-1, 60947-2, EN 60204, NF C 63-650, NF C63-120, 79-130, VDE 0113, 0660, UL 1077. UL, CSA, CCC UL, CSA, CCC, BV, DNV, GL, LROS, RINA TH TH 30 gn 5 gn (5 to 150 Hz) - 40+ 80 - 20+ 60 960 2000 30 gn 5 gn (5 to 150 Hz) - 40+ 80 - 20+ 60 960 2000
Solid cable
mm2
Flexible cable without cable end mm2 Flexible cable with cable end Tightening torque Suitable for isolation Conforming to IEC 60947-1 7-1-6 J mm2 N.m
0.5
Technical characteristics
Utilisation category Conforming to IEC 60947-2 Conforming to IEC 60947-4-1 Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated operational frequency Conforming to IEC 60947-2 Conforming to IEC 60947-2 Conforming to IEC 60947-2 V V Hz kV W C.O. C.O. C.O./h A AC-3 690 690 50/60 6 1.8 100 000 100 000 40 Continuous duty A AC-3 690 690 50/60 6 1.8 100 000 100 000 40 Continuous duty
Rated impulse withstand Conforming to IEC 60947-2 voltage (U imp) Total power dissipated per pole Mechanical durability For AC-3 duty (C.O.: Closing, Opening) Electrical durability for AC-3/415V duty (C.O.: Closing, Opening) Duty class (maximum operating rate) Rated duty Conforming to IEC 60947-4-1
Dimensions: pages 74 to 76
Schemes: page 77
14
Characteristics (continued)
Circuit-breaker type
Rating
230/240 V
kA
16 20 22
32
14 18 25
32
g g
g g
50
50
10
14
16
20
22
32
6.3 10
14
18
25
32
g g g g g g g g 4
g g g g 20 75 10
g g 50 50 20 75 10
g g 50 50 20 75 10 75 4
50
50
100 100 g 10 50 6 50 4 75 3 75 80 g g g g g g g g g
100 100 50 50 20 75 10 75 4 50 50 20 75 10 75 4
400/415 V
kA
g g
15 15 15 50 50 40 8 8 6
440 V
kA
g g
100 100 50 50 50 50 10 6 6 4
500 V
kA
g g
100 100 75 75 75 3 3 75 g g g g 50 63 50 63 32 40 3 3 3
100 75 4 4
690 V
kA
g g
75 75 75 g g g g g g g g g g g g g g g g g g g g 50 63 50 63
75 75 75 g g g g 80
100 100 100 100 100 100 100 100 g g g g g g g g 20 25 p p p p g g g g g g g g 25 32 p p p p g g g g g g g g 40 50 g g g g 50 63 50 63 40 50 g g 80 g g 100 100 125 125
Associated fuses (if required) if Isc > breaking capacity Icu conforming to IEC 60947-2 amendment 1
230/240 V
aM gG
A A A A A A A A A A kA kA
g g g g g g g g g g p p p p
100 100 g 80 g
400/415 V
aM gG
63 63 80
80 80 100 100 g 50 50 63 63 63 80 50 50 50 63 63 63 40 40 40 50 50 50 63 80 50 63 40 50 g g g g g g
440 V
aM gG
500 V
aM gG
690 V
aM gG
16 25 32 20 32 40 p p p p p p p p
Cable protection against thermal stress in the event of short-circuit (PVC insulated copper cables) Minimum c.s.a. protected at 40 C and at Isc max.
Dimensions: pages 74 to 76
Schemes: page 77
15
Characteristics
Environment
Circuit-breaker type Conforming to standards Protective treatment Degree of protection Shock resistance Vibration resistance Flame resistance Ambient air temperature Conforming to IEC 60529 Conforming to IEC 60068-2-27 Conforming to IEC 60068-2-6 Conforming to IEC 60695-2-1 Storage Operation Maximum operating altitude Operating position
30
GV3 L IEC/EN 60947-1, 60947-2 TH IP 20 On : 15 gn -11 ms Off : 30 gn -11 ms 5 gn (5300 Hz) C C C m 960 - 40+ 80 - 20+ 60 (1) 3000
GK3 EF80 IEC 60947-2, EN 60204 TC IP 20 22 gn -20 ms 2.5 gn (025 Hz) 960 - 40+ 80 - 20+ 70 open mounted 3000 Any position
30
9
90
Solid cable Flexible cable without cable end Flexible cable with cable end
Max. 1 x 35 1 x 25 or 2 x 16 1 x 25 or 2 x 16
Yes
Technical characteristics
Rated insulation voltage (Ui) Rated impulse withstand voltage (U imp) Rated operational voltage (Ue) Rated operational frequency Conforming to IEC 60947-2 Conforming to IEC 60947-2 Conforming to IEC 60947-2 V kV V Hz C.O. C.O. C.O./h 690 6 690 50/60 50 000 50 000 25 14 I max A 750 10 690 5060 1500 20 000 40 3363 A
Electrical durability for AC-3/415V duty (C.O.: Close - Open) Mechanical durability (C.O.: Closing, Opening) Maximum operating rate Operating threshold of magnetic trips Utilisation category Conforming to IEC 60947-2
(1) Leave a space of 9 mm between 2 circuit-breakers: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible up to 40 C.
Dimensions: pages 74 to 76
Schemes: page 77
16
Characteristics (continued)
Minimum cable length (in metres) limiting the maximum short-circuit current to 35 kA maximum, so enabling breakers GK3 EF80 to be used without fuses mm2 50 kA 45 kA 40 kA 37 kA m m m m y 25 5 5 5 5 35 6 5 5 5 50 8 7 5 5 70 10 8 5 5 95 13 10 8 5 120 15 12 9 5
g Fuse not required: breaking capacity Icn > Isc. (1) As % of Icu
Dimensions: pages 74 to 76
Schemes: page 77
17
Characteristics
Type of contacts
Instantaneous auxiliary GV AN, GV AD Conforming to IEC 60947-1 V 690 600 6 5 100 000 AC-15/100 000 C.O. V VA kVA A 48
Rated insulation voltage (Ui) (associated insulation coordination) Conventional thermal current (Ith)
Fault signalling GV AD, GV AM11 (1) 690 300 2.5 1 1000 AC-14/1000 C.O. 48 48
Instantaneous auxiliary GV AE 250 (690 in relation to main circuit) 300 2.5 1 100 000 AC-15/100 000 C.O. 48 60 110 230 127 240 120 120 1.27 2.4 0.5
Conforming to CSA C22-2 n 14 V and UL 508 Conforming to IEC 60947-5-1 A Conforming to CSA C22-2 n 14 A and UL 508 C.O.
Mechanical durability (C.O.: Close - Open) Operational power and current conforming to IEC 60947-5-1. a.c. operation Rated operational voltage (Ue) Operational power, normal conditions Occasional breaking and making capacities, abnormal conditions Rated operational current (Ie) Operational power and current conforming to IEC 60947-5-1. d.c. operation Rated operational voltage (Ue) Operational power, normal conditions Occasional breaking and making capacities, abnormal conditions Rated operational current (Ie) Low power switching reliability of contact Minimum operational conditions d.c. operation Short-circuit protection Cabling, screw clamp terminals Number of conductors Solid cable Flexible cable without cable end Flexible cable with cable end Tightening torque
110 230 380 440 500 690 24 127 240 415 300 500 720 850 650 500 400 36 3 6 7 4.5 13 3.3 15 2.2 13 1.5 12 1 9 0.6
1.25 1
DC-13/100 000 C.O. V W W A 24 110 240 (2) 140 240 180 140 120 240 360 240 210 180 6 5 3 1.3 0.5 48 60
DC-13/1000 C.O. 24 24 48 15 60 9 50
100 50 1 0.3
100 50 1 0.3
0.15
0.15
V mA
GV AE: Number of failures for n million operating cycles (17 V-5 mA): = 10-6 17 5 By GB2 CBpp circuit-breaker (rating according to operational GB2 CB06 or gG fuse current for Ue y 415 V) or by gG fuse 10 A max 10 A max 1 2 12.5 12.5 0.752.5 0.752.5 0.751.5 0.751.5 1.4 max 1.4 max GV AN only 0.752.5
0
Flexible cable without cable end mm2 Operation of instantaneous auxiliary contacts
Power pole
0.752.5
1
F F F O F O F F F O F O
Contact open Contact closed
GV AM11 Change of state following tripping on short-circuit. GV AD10pp and GV AD01pp Change of state following tripping on short-circuit, overload or undervoltage.
(1) For application example of fault signalling contact and short-circuit signalling contact, see page 72. (2) Add an RC circuit type LA4 D to the load terminals, consult our catalogue "Control and protection components".
References: page 55
18
Characteristics
Instantaneous auxiliary contacts GV3 A01A07 690 600 (B600) 6 5 (B600) 100 000 48 110 220 380 127 240 415 AC-11/100 000 C.O. 350 500 4 6 24 12 4.5 48 800 20 3.5 60 850 20 2.2 110 440 500 690
Fault signalling contacts GV3 A08 and A09 690 600 (B600) 6 5 (B600) 1000 48 110 220 380 127 240 415 AC-11/1000 C.O. 240 460 2.4 5 24 8 3.6 48 800 12 3.5 60 850 15 2.2 110 440 500 690
Conforming to CSA C22-2 n 14, V UL 508 Conforming to IEC 60947-5-1 A Conforming to CSA C22-2 n 14, A UL 508 C.O. Rated operational voltage (Ue) Operational power V
Mechanical durability (C.O.: Close - Open) Operational power and current conforming to IEC 60947-5-1 a.c. operation
VA Occasional breaking and making capacities Operational current (Ie) Operational power and current conforming to IEC 60947-5-1 d.c. operation Rated operational voltage (Ue) Operational power kVA A V
700 15 1.5
400 10 0.6
450 12 1 220
450 12 1
200 8 0.3
DC-11/100 000 C.O. W 180 240 240 360 6 5 180 240 3 140 210 1.3 120 180 0.5
DC-11/1000 C.O. 120 120 180 180 5 2.5 90 135 1.5 70 105 0.7 60 90 0.3
Occasional breaking and making capacities Operational current (Ie) Short-circuit protection Connection Number of conductors Solid cable
W A
By GB2 CB08 circuit-breaker or gG fuse, 6A max 1 mm2 12.5 0.752.5 0.752.5 2 12.5 0.752.5 0.751.5 GV3 A08 and A09 change state following tripping on short-circuit or overload
Flexible cable without cable end mm2 Flexible cable with cable end Contact operation mm2
0
Power pole
GV3 A03
GV3 A05
GV3 A06
References: page 59
19
Characteristics
A C.O.
6 50 000 AC-12 or AC-15. 50 000 C.O. 24 48 110 230/ 380/ 440 240 415 6 6 6 6 6 6 6 6 5 4 3 3
6 50 000 AC-12 or AC-15. 50 000 C.O. 24 48 110 230/ 380/ 440 240 415 5 5 5 5 5 5 5 5 4 3 2.5 2.5
V AC-12 AC-15 A A
690 6 0.1
690 5 0.1
V DC-12 DC-14 A A V mA
DC-12 or DC-14. 50 000 C.O. 24 48 110 2.5 1 17 5 2.5 0.2 0.8 0.5
250 0.3
250
0.03 0.5 12 5
By GB2 CBpp circuit-breaker (rating according to operational current for Ue y 415 V) or gG fuse, 10 A max. 1 x 1.5 conductor 1 x 1.5 conductor 1 x 1.5 conductor 1 x 1.5 conductor 1 x 1.5 conductor 1 x 1.5 conductor
Flexible cable without cable end mm2 Flexible cable with cable end mm2
References: page 61
20
Characteristics
V VA
Occasional breaking and making VA capacities Rated operational current (Ie) A Operational power and current conforming to IEC 60947-5-1 d.c. operation (C.O.: Close - Open)
Rated operational voltage (Ue) Operational power Occasional breaking and making capacities Rated operational current (Ie)
V W W A
60 180 240 3
By GB2 CB08 circuit-breaker or gG fuse, 6A max 1 x 14 conductor 1 x 2.5 conductor 1 x 12.5 conductor or 2 x 12.5 conductors 0.8
Flexible cable without cable end mm2 Flexible cable with cable end Tightening torque mm2 N.m
References: page 59
21
Characteristics
600 (B600) 600 (B600) 600 0.81.1 Un 0.70.35 Un 12 7 7 2.5 0.85 1.1 Un 0.35 0.7 Ue < 10 <5 <5 <5
Sealed consumption
a c
Operating time
From the moment the voltage reaches its operational value until opening of the circuit-breaker. 1015 10 15 < 50 100 % 100 % 1 or 2 12.5 0.752.5 0.752.5 1.2 100 % 1 1.5 1.5 1 1.2
Flexible cable without cable end mm2 Flexible cable with cable end Tightening torque Mechanical durability (C.O.: Close - Open) mm2 N.m C.O.
30 000 (GV2 ME and GV2 P) 50 % of the mechanical durability of the 10 000 (GV3 P and GV3 L) circuit-breaker (1) Wiring scheme of undervoltage trip for dangerous machines (conforming to INRS) on GV2 ME only, see page 72.
References: page 61
Dimensions: pages 66 to 71
22
Characteristics
Characteristics of terminal blocks GV2 G05 and GV1 G09 (for GV2 ME and GV2 P)
Rated insulation voltage (Ui) Conventional thermal current (Ith) Degree of protection Connection Conforming to IEC 60947-1 Conforming to IEC 60439-1 Conforming to IEC 60529 Solid cable mm2 V A 690 63 IP 20 1 x 1.5 to 25 conductor or 2 x 1.5 to 10 conductors 1 x 1.5 to 25 conductor or 2 x 2.5 to 10 conductors 1 x 1.5 to 16 conductor or 2 x 1.5 to 4 conductors 2.2 1.7
Flexible cable without cable end mm2 Flexible cable with cable end Tightening torque Connector Screw clamp terminals mm2 N.m N.m
Flexible cable without cable end mm2 Flexible cable with cable end Tightening torque mm2 N.m
References: page 63
23
Curves
10 000
1000
100
1
10
2 3
0,1
0,01
0,001
1,5
10
100
x the setting current (Ir)
1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state
Dimensions: pages 66 to 68
Schemes: page 72
24
Curves (continued)
100
1
=0 .25
0.
2 3 4 5 6
10
0.7
0. 5
7 8
0.
0.
9
= co s 0.9 5
10
11
0,1 0,1
10
15 (12)
1 Maximum peak current 2 24 -32 A 3 20 -25 A 4 17 -23 A 5 13 -18 A 6 9 -14 A 7 6 -10 A 8 4 -6.3 A 9 2.5 -4 A 10 1.6 -2.5 A 11 1 -1.6 A 12 Limit of rated ultimate breaking capacity on short-circuit of GV2 ME (14, 18, 23 and 25 A ratings)
Dimensions: pages 66 to 68
Schemes: page 72
25
Curves (continued)
100 1
2 3 4 5 6 7
10
9
1
10
0,1
0,01 0,1
10
1 2 3 4 5 6 7 8 9 10
24 -32 A 20 -25 A 17 -23 A 13 -18 A 9 -14 A 6 -10 A 4 -6.3 A 2.5 -4 A 1.6 -2.5 A 1 -1.6 A
Dimensions: pages 66 to 68
Schemes: page 72
26
Curves (continued)
100
1 2 3 4 5 6
10
0,1
0,01 0,1
10
1 1 2 3 4 5 6 7 8 9
24 -32 A 20 -25 A 17 -23 A 13 -18 A 9 -14 A 6 -10 A 4 -6.3 A 2.5 -4 A 1.6 -2.5 A 1 -1.6 A
Dimensions: pages 66 to 68
Schemes: page 72
27
Curves
10 000
1000
100
1
10
4 2
0,1
0,01
0,001
10
100
x the setting current (Ir)
1 2 3 4
3 poles from cold state (GV3 P) 3 poles from hot state (GV3 P) 3 poles from cold state (GV3 ME80) 3 poles from hot state (GV3 ME80)
References: page 48
Dimensions: page 69
Schemes: page 73
28
Curves (continued)
100
1 2
0. 5
0.
=0 .25
3 4
5 6 7 8
10
0.7
1 2 3 4 5 6 7 8 9
Maximum peak current 56 -80 A 48 -65 A 37 -50 A 30 -40 A 23 -32 A 17 -25 A 12 -18 A 9 -13 A
References: page 48
0.
0.
Dimensions: page 69
Schemes: page 73
29
Curves (continued)
1000
2 3 4 5 6 7
100
10
1 2 3 4 5 6 7 8
56-80 A (GV3 ME80) 48-65 A (GV3 P65) 37-50 A (GV3 P50) 30-40 A (GV3 P40) 23-32 A (GV3 P32) 17-25 A (GV3 P25) 12-18 A (GV3 P18) 9-13 A (GV3 P13)
References: page 49
Dimensions: page 69
Schemes: page 73
30
Curves
10 000 5000
200 100 50
20 10 5
1
2 1 0,5
3
0,2 0,1 0,05
1 Cold state curve 2 Cold state curve 3 1214 Ir In the event of total phase failure, tripping occurs after 4 s 20 %
References: page 49
Dimensions: pages 69 to 71
Schemes: page 73
31
Curves (continued)
100 80 70 60 50 40 30
20
1 2
10 8 7 6 5 4 2 3 4 5 6 10 20 30 40 100 50 60 70 Prospective Isc (kA)
100 80 70 60 50 40 30
20
1 2
10 8 7 6 5 4 2 3 4 5 6 10 20 30 40 100 50 60 70 Prospective Isc (kA)
References: page 49
Dimensions: pages 69 to 71
Schemes: page 73
32
Curves (continued)
107
5x106 3x10
6
2x106
106
1
5x105 3x10 2x10
5
2 3
10
10
20
30
40
10
106
1
5x105 3x10
5
2 3
2x105
105
10
20
30
40
50 60 70
100
References: page 49
Dimensions: pages 69 to 71
Schemes: page 73
33
Curves (continued)
50 40
30
20
1 2
10
50 40
30
20
1 2
10
References: page 49
Dimensions: pages 69 to 71
Schemes: page 73
34
Curves (continued)
3x106
2x10
106
5x105
1 2
3x10
2x105
10
10
3x106
2x10
10
5x105
1 2
3x105
2x10
References: page 49
Dimensions: pages 69 to 71
Schemes: page 73
35
Curves
10 000
1000
100
2 1
10
0,1
0,01
0,001 1 10 100
k x Ir
1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state
References: page 50
Dimensions: page 68
Schemes: page 72
36
Curves
Tripping curves for GV2 L or LE combined with thermal overload relay LRD or LR2 K
Average operating times at 20 C related to multiples of the setting current
Time (s)
10 000
1000
100
1 2 3
10
0,1
0,01
1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state
Dimensions: pages 74 to 76
Schemes: page 77
37
Curves (continued)
Current limitation on short-circuit for GV2 L and GV2 LE only (3-phase 400/415 V)
Dynamic stress I peak = f (prospective Isc) at 1.05 Ue = 435 V
Limited peak current (kA)
100
1
=
= 0. 3
0.2 5
2 3 4
0. 5
5 6
10
0. 7
7 8 9
0.9
0.
10
0,1 0,1
co
=0
1
.95
10
15
100
Prospective Isc (kA)
11
1 2 3 4 5 6 7 8 9 10 11
Maximum peak current 32 A 25 A 18 A 14 A 10 A 6.3 A 4A 2.5 A 1.6 A Limit of rated ultimate breaking capacity on short-circuit of GV2 LE (14, 18, 23 and 25 A ratings).
Dimensions: pages 74 to 76
Schemes: page 77
38
Curves (continued)
Current limitation on short-circuit for GV2 L and GV2 LE + thermal overload relay LRD or LR2 K (3-phase 400/415 V)
Dynamic stress I peak = f (prospective Isc) at 1.05 Ue = 435 V
Limited peak current (kA)
100
1
=0 .25
0.
2 3
4 5
10
0.
0.7
0.
6 7
0.
8
0.9 co s = 5
10
0,1 0,1
10
15
100
Prospective Isc (kA)
11
1 Maximum peak current 2 32 A 3 25 A 4 18 A 5 14 A 6 10 A 7 6.3 A 8 4A 9 2.5 A 10 1.6 A 11 Limit of rated ultimate breaking capacity on short-circuit of GV2 LE (14, 18, 23 and 25 A ratings).
Dimensions: pages 74 to 76
Schemes: page 77
39
Curves (continued)
100
2 3 4 5 6
10
8
1
0,1
0,01 0,1
10
100
Prospective Isc (kA)
1 2 3 4 5 6 7 8 9
References: page 52
Dimensions: pages 74 to 76
Schemes: page 77
40
Curves (continued)
100
1 2 3 4 5 6
10
0,1
0,01 0,1
10
1 2 3 4 5 6 7 8
References: page 53
Dimensions: pages 74 to 76
Schemes: page 77
41
Curves (continued)
Thermal limit on short-circuit for GV2 L and GV2 LE + thermal overload relay LRD or LR2 K
Thermal limit in kA2s in the magnetic operating zone Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V
Sum of I2dt (kA2s)
100
2 1 3 4 5 6
10
0,1
10
0,01 0,1
10
15
1 2 3 4 5 6 7 8 9 10
32 A (GV2 LE32) 25 A and 32 A (GV2 L32) 18 A 14 A 10 A 6.3 A 4A 2.5 A 1.6 A Limit of rated ultimate breaking capacity on short-circuit of GV2 LE (14, 18, 23 and 25 A ratings).
Dimensions: pages 74 to 76
Schemes: page 77
42
Curves
Tripping curves for GV3 L and GK3 EF80 combined with thermal overload relay LRD 33
Average operating time at 20 C without prior current flow
Time (s)
10 000
1000
100
A 1 2 3
10
0,1
0,01
0,001 1 10 100
x the setting current (Ir)
1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state A Thermal overload relay protection zone B GK3 EF80 and GV3 protection zone L
References: page 53
Dimensions: page 76
Schemes: page 77
43
Curves (continued)
Current limitation on short-circuit for GV3 L and GK3 EF80 (3-phase 400/415 V)
Dynamic stress I peak = f (prospective Isc) at 1.05 Ue = 435 V
Limited peak current (kA)
50
1 3 4 5
6 7
10
1 1 10 100
Prospective Isc (kA)
1 2 3 4 5 6 7
Maximum peak current GK3 EF80 GV3 L65 GV3 L50 GV3 L40 GV3 L32 GV3 L25
References: page 53
Dimensions: page 76
Schemes: page 77
44
Curves (continued)
1000
2 3 4 5 6 1
100
10
1 1 10 100
Prospective Isc (kA)
1 2 3 4 5 6
GK3 EF80 GV3 L65 GV3 L50 GV3 L40 GV3 L32 GV3 L25
References: page 53
Dimensions: page 76
Schemes: page 77
45
References
533886
GV2 ME01
kg 0.260
0.09
0.250.40
GV2 ME03
0.260
g g g
g g g
0.37 g 0.55 g
g g
0.400.63
GV2 ME04
0.260
0.631
13
GV2 ME05
0.260
g g g
g g g
g g g g
g g g g
g g 3
g g 75
116
22.5
GV2 ME06
0.260
1.62.5
33.5
GV2 ME07
0.260
g g g
g g g
1.5 2.2 3
g g 50
g g 100
2.2 3 4
3 3 3
75 75 75
2.54
51
GV2 ME08
0.260
46.3
78
GV2 ME10
0.260
3 4 5.5 7.5
g g 15 15
g g 50 50
4 5.5 7.5 9
10 10 6 6
100 100 75 75
5.5 7.5 9 11 15
3 3 3 3 3
75 75 75 75 75
610
138
GV2 ME14
0.260
914
170
GV2 ME16
0.260
1318
223
GV2 ME20
0.260
15
40
11
75
18.5 3
75
1723
327
GV2 ME21
0.260
11
15
40
15
75
2025
327
0.260
15
10
50
18.5 4
75
22
75
2432
416
GV2 ME32
0.260
Characteristics: pages 8 to 11
Dimensions: pages 66 to 68
Schemes: page 72
46
References (continued)
533897
GV2 ME013 GV2 ME023 GV2 ME033 GV2 ME043 GV2 ME053 GV2 ME063
GV2 ME073 GV2 ME083 GV2 ME103 GV2 ME143 GV2 ME163 GV2 ME203 GV2 ME213 GV2 ME223
Contact blocks
Description Instantaneous auxiliary contacts Mounting Front LH side Maximum number 1 2 Type of contacts N/O + N/C N/O + N/O N/O + N/C N/O + N/O Sold in lots of 10 10 1 1 Unit reference GV AE113 GV AE203 GV AN113 GV AN203 Weight kg 0.030 0.030 0.060 0.060
Accessory
Description Cable end reducer LA9 D99 (1) For connection of conductors from 1 to 1.5 mm2, the use of an LA9 D99 cable end reducer is recommended. (2) Maximum rating which can be mounted in enclosures GV2 MC or MP, please consult your Regional Sales Office (3) The thermal trip setting must be within the range marked on the graduated knob. g > 100 kA. Application For connection of conductors from 1 to 1.5 mm2 Sold in lots of 20 Unit reference LA9 D99 Weight kg
Characteristics: pages 8 to 11
Dimensions: pages 66 to 68
Schemes: page 72
47
References
510564
Ics (1) %
kg
510563
To order thermal magnetic circuit-breakers with connection by lugs, add the digit 6 to the end of reference selected above. Example: GV3 P18 becomes GV3 P186. GV3 ME80: pushbutton control, screw clamp terminals
37 15 50 45 4 100 55 2 100 5680 GV3 ME80 (4) 0.700
Characteristics: pages 8 to 12
Dimensions: pages 66 to 68
48
References
533900
Ics (1) % 100 100 100 100 100 100 100 100 100
GV7 RE20
kg 2.010
1220
GV7 RS20
2.010
1525
GV7 RE25
2.010
1525
GV7 RS25
2.010
533901
2540
GV7 RE40
2.010
18.5
70
100
22
10
100
2540
GV7 RS40
2.010
22
36
100
30
18
100
30
100
3050
GV7 RE50
2.015
22 GV7 RS 37
70
100
30
50
100
30
10
100
3050
GV7 RS50
2.015
36
100
45 55 45 55
18 18 50 50 18
55
100
4880
GV7 RE80
2.040
37
70
100
55
10
100
4880
GV7 RS80
2.040
45
36
100
75
100
60100
GV7 RE100
2.040
45
70
100
50
100
75
10
100
60100
GV7 RS100
2.040
55 75 55 75 90 110 90 110
35 35 70 70 35 35 70 70
30 30 50 50
8 8 10 10 8 8 10 10
90150
GV7 RE150
2.020
90150
GV7 RS150
2.020
132220
GV7 RE220
2.350
132220
GV7 RS220
2.350
Characteristics: page 13
Dimensions: page 69
Schemes: page 73
49
References
510570
GV2 RT03
kg 0.350
0.400.63
13
GV2 RT04
0.350
0.37
0.55
0.631
22
GV2 RT05
0.350
11.6
33
GV2 RT06
0.350
1.62.5
51
GV2 RT07
0.350
1.5 2.2 3
2.2 3 4
2.54
78
GV2 RT08
0.350
2.2 3 4
46.3
138
GV2 RT10
0.350
3 4 5.5
4 5.5 7.5
5.5 7.5 9 11 15
610
200
GV2 RT14
0.350
914
280
GV2 RT16
0.350
7.5
1318
400
GV2 RT20
0.350
5.5
9 11
11
18.5
1723
400
GV2 RT21
0.350
(1) The thermal trip setting must be within the range marked on the graduated knob.
Characteristics: pages 8 to 23
Dimensions: page 68
Schemes: page 72
50
References (continued)
510570
GV2 RT03
kg 0.350
GV2 RT
0.400.63
13
GV2 RT04
0.350
0.63
0.63
0.631
22
GV2 RT05
0.350
0.4
0.63
11.6
33
GV2 RT06
0.350
0.63
1.6
1.6 2 2.5
1.62.5
51
GV2 RT07
0.350
1.6 2 2.5
1.6 2 2.5 4 5
2 2.5 4
2.54
78
GV2 RT08
0.350
1.6 2 2.5
4 5 6.3
5 6.3
4 5 6.3
46.3
138
GV2 RT10
0.350
610
200
GV2 RT14
0.350
6.3
10 12.5 10
914
280
GV2 RT16
0.350
5 6.3
10
10
10 12.5
1318
400
GV2 RT20
0.350
Accessory (2)
Description Padlockable external operator (IP 54) black handle, blue legend plate Reference GV2 AP03 Weight kg 0.280
(1) The thermal trip setting must be within the range marked on the graduated knob. (2) Other accessories such as mounting, cabling and marking accessories are identical to those used for GV2 ME motor circuit-breakers, see page 63.
Characteristics: pages 8 to 23
Dimensions: page 68
Schemes: page 72
51
References
534101
g g g g g g g g g g g g g 50 50 40 40 50
g g g g 75 75 75 75 75 75 75 75 75 75
kg 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330
0.37 g
0.55 g
0.25 g
0.37 g 0.55 g
LR2 K0321 GV2 LE16 LRD 21 LRD 22 LRD 22 LRD 32 GV2 LE20 GV2 LE22 GV2 LE22 GV2 LE32
18.5 3 22 3
18.5 4
(1) As % of Icu.
Dimensions: page 74
Schemes: page 77
52
References
Use in Reference association with thermal overload relay LRD 03 LRD 04 LRD 04 LRD 05 LRD 05 LRD 06 LRD 05 LRD 06 LRD 06 LRD 07 LRD 08 LRD 08 LRD 08 LRD 10 LRD 12 LRD 14 LRD 14 LRD 16 LRD 16 LRD 21 LRD 22 LRD 22 LRD 32 GV2 L03 GV2 L04 GV2 L04 GV2 L05 GV2 L05 GV2 L05 GV2 L05 GV2 L06 GV2 L06 GV2 L07 GV2 L08 GV2 L08 GV2 L08 GV2 L10 GV2 L14 GV2 L14 GV2 L14 GV2 L16 GV2 L16 GV2 L20 GV2 L22 GV2 L22 GV2 L32
Weight
GV2 L pp
g g g g g g g g g g 50 50 50 50 50
g g g g g g 100 75 75 75 75 75
g g g g 100 100 100 100 100 100 100 100 100 100
kg 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330 0.330
510531
GV3 Lpp
50 50 50 50 50
50 50 50 50 50
50 50 60 60 60
534103
15
100
18.5 12 22 30 37 10 10 10
18,5 50 22 30 50 50
Connection by lugs
To order these circuit-breakers with connection by lugs, add the digit 6 to the end of reference selected above. Example: GV3 L32 becomes GV3 L326. GK3: control by rotary knob, connection by screw clamp terminals
GK3 EF80 37 35 25 55 15 30 80 1040 LRD3363 GK3 EF80 0,795
(1) As % of Icu. Associated current limiter or fuses, where required. See characteristics page 17. g > 100 kA.
Dimensions: pages 74 to 77
Schemes: page 77
53
GV2 AK00
GV1 L3
GV AX
GV2 ME
GV AD GV AM11
GV AU
GV2 P
GV AM11
GV AS
GV2 L
GV AE11, GV AE20
54
References
Contact blocks
Description Instantaneous auxiliary contacts Mounting Front (1) Maximum number 1 Type of contacts N/O or N/C (2) N/O + N/C N/O + N/O N/O + N/C N/O + N/O N/O (fault) + N/O + N/C N/C (fault) + N/O + N/C C/O common point Sold in lots of 10 10 10 1 1 1 1 1 1 1 Unit reference GV AE1 GV AE11 GV AE20 GV AN11 GV AN20 GV AD1010 GV AD1001 GV AD0110 GV AD0101 GV AM11 Weight kg 0.015 0.020 0.020 0.050 0.050 0.055 0.055 0.055 0.055 0.045
Side (LH) Fault signalling contact + instantaneous auxiliary contact Side (3) (LH)
2 1
Side (LH)
Electric trips
Mounting Voltage Reference Weight kg 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105
Undervoltage trip, INRS (can only be mounted on GV2 ME) Safety device for dangerous machines conforming to INRS and VDE 0113.
Side (1 block on RH side of circuit-breaker GV2 ME) 110115 V 127 V 220240 V 380400 V 415440 V 440 V 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz Maximum number 1 1 1 GV AX115 GV AX116 GV AX115 GV AX225 GV AX226 GV AX385 GV AX386 GV AX415 GV AX385 Reference GV2 AK00 GV1 L3 LA9 LB920 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 Weight kg 0.150 0.130 0.320
LA9 LB920
(1) Mounting of a GV AE contact block or a GV2 AK00 visible isolation block on GV2 P and GV2 L (2) Choice of N/C or N/O contact operation, depending on which way round the reversible block is mounted. (3) The GV AD is always mounted next to the circuit-breaker. (4) To order an undervoltage trip: replace the dot (p) in the reference with a U, example: GV AU025. To order a shunt trip: replace the dot (p) in the reference with an S, example: GV AS025 . (5) Visible isolation of the 3 poles upstream of circuit-breaker GV2 P and GV2 L. Visible isolation block GV2 AK00 cannot be used with motor circuit-breakers GV2 P32 and GV2 L32 (Ith max = 25 A). Dimensions, schemes: pages 66 to 77
Characteristics: pages 18 to 23
55
GV AM11 GV3 P
GV AM11
GV AE1 GV AE1
GV2 V03
56
References
Contact blocks
Description Instantaneous auxiliary contacts Mounting Front Maximum number 1 Type of contacts N/O or N/C (1) N/O + N/C N/O + N/O N/O + N/C N/O + N/O N/O (fault) + N/O N/O (fault) + N/C N/O (fault) + N/O + N/C N/C (fault) + N/O + N/C C/O common point Sold in lots of 10 10 10 1 1 1 1 1 1 1 1 1 Unit reference GV AE1 GV AE11 (2) GV AE20 (2) GV AN11 (2) GV AN20 (2) GV AED101 (2) GV AED011 (2) GV AD1010 GV AD1001 GV AD0110 GV AD0101 GV AM11 Weight kg 0.015 0.020 0.020 0.050 0.050 0.020 0.020 0.055 0.055 0.055 0.055 0.045
Side (LH) Fault signalling contact + instantaneous auxiliary contact Front Side (3) (LH)
2 1 1
Side (LH)
Electric trips
Mounting Voltage Reference Weight kg 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105 0.105
Accessories
Description For circuit-breakers Reference Set of 3-pole GV3 Ppp and GV3 Lpp GV3 G364 115 A busbars 3 tap-offs. Pitch: 64 mm GV3 Ppp GV3 G66 0.020 Cover Large Spacing UL 508 type E (Only one cover required on supply side) GV3 Ppp6 and GV3 Lpp 6 LAD 96570 0.021 IP 20 cover (Two covers required per breaker) GV3 Ppp and GV3 Lpp GV2 V03 0.092 Padlocking device GV3 Ppp6 and GV3 Lpp 6 for use with up to 4 padlocks (not supplied) 6 mm shank max. (1) Choice of N/C or N/O contact operation, depending on which way round the reversible block is mounted. (2) Contact blocks available in version with spring terminal connections. Add a figure 3 at the end of the references selected above. Example: GV AED101 becomes GV AED1013 . (3) The GV AD is always mounted next to the circuit-breaker. (4) To order an undervoltage trip: replace the dot (p) in the reference with a U, example: GV AU025. To order a shunt trip: replace the dot (p) in the reference with an S, example: GV AS025 . Weight kg 0.25
GV3 G66
LAD 96570
Characteristics: pages 18 to 23
57
GV3 A01...A07
58
References
Electric trips
Description Udervoltage trips (1) Voltages 50 Hz 110, 120, 127 V 220, 240 V 380, 415 V 110, 120, 127 V 220, 240 V 380, 415 V Reference 60 Hz 120, 127 V 277 V 440 V, 480 V 120, 127 V 277 V 440 V, 480 V GV3 B11 GV3 B22 GV3 B38 GV3 D11 GV3 D22 GV3 D38 Weight kg 0.070 0.070 0.070 0.070 0.070 0.070
Accessory
Description Padlocking device, for locking the Start button (on open-mounted product) Sold in lots of 5 Unit reference GV1 V02 Weight kg 0.010
Accessories
Description Padlocking device for padlocking the operator, using up to 3 padlocks (padlocks to be ordered separately) External operator for mounting on enclosure door. Red 40 knob on yellow plate, padlockable in position O (with up to 3 padlocks). Door locked when knob in position I, and when knob padlocked in position O. Reference GK3 AV01 Weight kg 0.020
GK3 AP03
0.300
(1) 1 voltage trip OR 1 fault signalling contact to be fitted inside the motor circuit-breaker.
Other versions
24 to 690 V, 50 or 60 Hz voltage trips for circuit-breakers GV3 ME80. Please consult your Regional Sales Office.
59
4 3 2 1
GV7 RE, RS
GV7 AU, AS
60
References
Electric trips
These allow the circuit-breaker to be tripped via an electrical control signal. b Undervoltage trip GV7 AU v Trips the circuit-breaker when the control voltage drops below the tripping threshold, which is between 0.35 and 0.7 times the rated voltage. v Circuit-breaker closing is only possible if the voltage exceeds 0.85 times the rated voltage. Circuit-breaker tripping by a GV7 AU trip meets the requirements of IEC 60947-2. b Shunt trip GV7 AS Trips the circuit-breaker when the control voltage rises above 0.7 times the rated voltage. b Operation (GV7 AU or GV7 AS) v When the circuit-breaker has been tripped by a GV7 AU or AS, it must be reset either locally or by remote control. (For remote control, please consult your Regional Sales Office). v Tripping has priority over manual closing: if a tripping instruction is present, manual action does not result in closing, even temporarily, of the contacts. v Durability: 50 % of the mechanical durability of the circuit-breaker.
Type Undervoltage trip Voltage 48 V, 50/60 Hz 110130 V, 50/60 Hz 200240 V, 50/60 Hz 380440 V, 50/60 Hz 525 V, 50 Hz 48 V, 50/60 Hz 110130 V, 50/60 Hz 200240 V, 50/60 Hz 380440 V, 50/60 Hz 525 V, 50 Hz Reference GV7 AU055 (1) GV7 AU107 (1) GV7 AU207 (1) GV7 AU387 (1) GV7 AU525 (1) GV7 AS055 (1) GV7 AS107 (1) GV7 AS207 (1) GV7 AS387 (1) GV7 AS525 (1) Weight kg 0.105 0.110 0.110 0.105 0.100 0.105 0.110 0.110 0.105 0.100
Shunt trip
Dimensions: pages 69 to 71
Schemes: page 73
61
TRIP
RESE
62
References
Accessories
Description Adapter plates Application For mounting a GV2 ME or GV2 LE by screw fixing For mounting a GV2 ME or GV2 P and contactor LC1 D09D38 with front faces aligned 7,5 mm Between GV2 and contactor LC1 K or LP1 K Between GV2 and contactor LC1 D09D38 Between GV2 mounted on LAD 311 and contactor LC1 D09D38 With 3-pole connection for mounting a GV2 and a contactor LC1 D09D25 Application 2 tap-offs Sold in lots of 10 1 Unit reference GV2 AF02 LAD 311 Weight kg 0.021 0.040
10 10 10 10
GK2 AF01
0.120
3 tap-offs 4 tap-offs
5 tap-offs Description Protective end cover Terminal block for supply to one or more GV2 G busbar sets Cover for terminal block Flexible 3-pole connection for connecting a GV2 to a contactor LC1-D09D25 Application For unused busbar outlets Connection from the top Can be fitted with current limiter GV1 L3 (GV2 ME and GV2 P) For mounting in modular panels Centre distance between mounting rails: 100120 mm
Reference GV2 G245 GV2 G254 GV2 G272 GV2 G345 GV2 G354 GV2 G445 GV2 G454 GV2 G472 GV2 G554 Unit reference GV1 G10 GV1 G09 GV2 G05
Weight kg 0.036 0.038 0.042 0.058 0.060 0.077 0.085 0.094 0.100 Weight kg 0.005 0.040 0.115
10 10
0.005 0.013
Set of connections upstream/downstream Large Spacing adapter UL 508 type E Clip-in marker holders (supplied with each circuit-breaker)
10
GV2 GA01
0.045
For GV2 PppH7 (except 32 A) For GV2 P, GV2 L, GV2 LE and GV2 RT (8 x 22 mm)
1 100
0.040 0.001
For GV2 LE
GV2 AP03
0.280
Padlocking device
Description For all GV2 device For use with up to 4 padlocks, 6 mm shank max. (padlocks not included) Reference GV2 V03 Weight kg 0.092
Dimensions: pages 66 to 77
63
ON
ON
OFF
GV7 AP04
O
OFF
ON
ON
OFF
ON
OFF
ON
OFF
OFF
GV7 AP05
GV7 AC04
GV7 AC01
GV7 V01
GV7 RE, RS
GV7 AC04
GV7 AC03
GV7 AC01
64
References
Cabling accessories
Description Application For use on contactors Sold in lots of 3 3 1 Unit reference GV7 AC021 GV7 AC022 GV7 AC03 Weight kg 0.300 0.350 0.180
Spreader 3-pole (1) Terminal shields IP 405 (1) Phase barriers Insulating screens Kits for combination with contactor(2)
Supplied with sealing accessory Safety accessories used when fitting of shields is impossible Ensure insulation between the connections and the backplate Allowing link between the circuit-breaker and the contactor. The cover provides protection against direct finger contact
GV7 AC01
0.125
GV7 AC07
LC1 F115F185
2 2 1
GV7 AC04 GV7 AC05 GV7 AC06 GV7 AC07 GV7 AC08
GV7 AC08
Replaces the circuit-breaker front cover; secured by screws. It includes a device for locking the circuit-breaker in the O (Off) position by means of up to 3 padlocks with a shank diameter of 5 to 8 mm (padlocks not included). A conversion accessory allows the direct rotary handle to be mounted on the enclosure door. In this case, the door cannot be opened if the circuit-breaker is in the ON position. Circuit-breaker closing is inhibited if the enclosure door is open.
Description Direct rotary handle Type Black handle, black legend plate Red handle, yellow legend plate Adapter plate (3) Four mounting direct rotary handle on enclosure door Degree of protection IP 40 IP 40 IP 43 Reference GV7 AP03 GV7 AP04 GV7 AP05 Weight kg 0.205 0.205 0.100
Locking device
Allows circuit-breakers not fitted with a rotary handle to be locked in the O (Off) position by means of up to 3 padlocks with a shank diameter of 5 to 8 mm (padlocks not included).
Description Locking device Application For circuit-breaker not fitted with a rotary handle Reference GV7 V01 Weight kg 0.100
(1) Terminal shields cannot be used together with spreaders. (2) The kit comprises links, a protective shield and a depth adjustable metal bracket for the breaker. (3) This conversion accessory makes it impossible to open the door if the device is closed and prevents the device from being closed if the door is open.
Dimensions: pages 69 to 71
Schemes: page 73
65
Dimensions, mounting
Dimensions
GV2 ME GV AX GV AD, AM, AN, AU, AS, AX
Block GV AD, AM, AN Block GV AU, AS, AX
GV AE
X1
11
67,2
15 10
15,7
X1
46
44,5
45
16
9,3
9,3 81(1)
18
b GV2 MEpp 89 GV2 MEpp3 101 (1) Maximum X1 Electrical clearance = 40 mm for Ue y 690 V
GV2 P
GV2 AK00
14 98 32
X1
89
45 44,5
15
X2
26
50 82
61
9,3
9,3 81(1)
18 44,5
(1) Maximum X1 Electrical clearance = 40 mm for Ue y 415 V, or 80 mm for Ue = 440 V, or 120 mm for Ue = 500 and 690 V X2 = 40 mm
Mounting
GV2 ME
On 35 mm 5 rail On panel with adapter plate GV2 AF02 On pre-slotted plate AM1 PA On rails DZ5 MB201
4,2
AF1 EA4
15
35
50/60
50/60
c
c = 78.5 on AM1 DP200 (35 x 7.5) c = 86 on AM1 DE200, ED200 (35 x 15)
80
GV2 P
On rail AM1 DE200, ED200 (35 x 15) Panel mounted On pre-slotted plate AM1 PA Adapter plate GK2 AF01
44,5
55
84
84
44,5
45
135
106
13,5
13,5
24
9,5
66
35
50 60
Dimensions
GV2 AF01
Combination GV2 ME + k contactor
GV2 AF3
Combination GV2 ME + d contactor Combination GV2 P + d contactor
152
79
45 c1 c 45 c1 c d1 d
GV2 P + b c1 c d1 d LC1 D09D18 1764 1001 1056 95 1005
45
GV2 ME + b c1 c
40
X1
125 3
125 3
234
b 234
77
X1
44,5
c1 c d1 d
GV2 ME + b c1 c d1 d LC1 D09D18 1764 1031 1356 107 1125
45
c1 c
GV2 P + b c1 c
Mounting
Mounting of external operator GV2 AP01 or GV2 AP02 for motor circuit-breakers GV2 P
Door cut-out
65
=
= = 54
= 5,2 =
45
89
1,5...5 53 135284
67
54
129
GV2 ME, GV2 P Sets of busbars GV2 G445, GV2 G454, GV2 G472, with terminal block GV2 G05
a 3 18 l p
GV2 G445 (4 x 45 mm) GV2 G454 (4 x 54 mm) GV2 G472 (4 x 72 mm) l 179 206 260 a 5 224 260 332 p 45 54 72
63
45
GV2 RT Dimensions
X1 12,5 66
89
X1
7,5
16
44
44,5 53
45
65
1,5...5 133282 6 = =
Mounting
On 35 mm 7 mounting rail On panel with adapter plate GV2 AF02 On pre-slotted plate AM1 PA On rails DZ5 MB
4,2 44,5
13 AF1 EA4
15
35
50/60
50/60
44,5
c
c = 80 on AM1 DP200 (35 x 7.5) c = 88 on AM1 DE200, ED200 (35 x 15)
84,5
68
50 60
Dimensions, mounting
GV3 P
Dimensions
X1
X1
136
64
X1 = Electrical clearance (ISC max) 40 mm for Ue < 500 V, 50 mm for Ue < 690 V
(1) Blocks GV AN pp , GV ADpp , GV AM11 (2) Block GV3 AU pp and GV3 ASpp
3x4
136
37,5
136
Note: Leave a space of 9 mm between 2 circuit-breakers: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible up to 40 C.
GV7 R
Dimensions Motor circuit-breakers with terminal shields or phase barriers GV7 R + GV7 AC01 or AC04
35 = = = =
161
125
161
321
81 86 111 (1)
(1) 126 for GV7 Rp220
= 105
357
64
(2) 81
(2) Phase barriers: GV7 AC04 (3) Terminal shields: GV7 AC01
(3)
x1
x2
Painted or insulated metal plate, insulation or insulated bar Bare U y 440 V metal 440 V < U < 600 V plate U u 600 V
x1 0 5 10 20
x2 30 35 35 35
69
Dimensions, mounting
GV7 R
Panel mounting Mounting on 2 mounting rails DZ5 MB201
DZ5 ME5 = 125
135
35
35
35
15
35
Flush-mounting
1 circuit-breaker GV7 R n circuit-breakers GV7 R side-by-side
47
125
76
108
=
G 85 85 85 85 85 H 120 120 120 120 120
29
88
== 29
83
= 108
R + LC1 F115 + R + LC1 F150 + R + LC1 F185 + R + LC1 F225 + R + LC1 F265 +
GV7 AC06 GV7 AC06 GV7 AC06 GV7 AC07 GV7 AC07
E 44 46 48 57 60
70
108
Connection
Smooth terminals Connectors
Z 10,5 a Z 19 Z
30
41
X 70 70 X
a 19.5 21.5
I 45 73 47 89 = 97 =
Front face cut-out Enclosure viewed from top
121 155
55 91
36
Direct rotary handle GV7 AP03 or GV7 AP04 with conversion accessory GV7 AP05
9,25 h
120
59
41
100
Door cut-outs require a minimum distance between the centre of the circuit-breaker and the door hinge point u 100 + (h x 5).
125 2
69 120
51
= 100
e = 1 to 3 max
60 l = 75
l: 185 min, 600 max The shaft of the extended rotary handle GV7 AP01 or GV7 AP02 2 must be cut to length: l 126 mm.
75
29
28
76
71
Schemes
Schemes
GV2 MEpp and GV2 RT
1/L1 3/L2 5/L3
GV2 Ppp
1/L1 3/L2 5/L3
GV3 Ppp
1/L1 3/L2 4/T2 5/L3 6/T3
2/T1
4/T2
6/T3
2/T1
4/T2
6/T3
Front mounting add-on contact blocks Instantaneous auxiliary contacts and fault signalling contacts
GV AED101 GV AED011
GV AE11
GV AE20
97 98 97 98
10Agl max
97
11
13
13
21
13
23
23
98
14
12
14
22
14
Side mounting add-on contact blocks Instantaneous auxiliary contacts and fault signalling contacts
GV AD0110 GV AD0101 GV AD1010 GV AD1001
95
53
95
51
24
24
97
53
96
96
52
98
54
GV AN20
(63) 33 43 (73)
(62) 32
44 (74)
(64) 34
44 (74)
Voltage trips
GV AUppp GV ASppp GV AXppp
D1 D2
Current limiter
GV1 L3
1/L1 3/L2 5/L3
D1
D2
C2
C1
E1
E2
Connection of undervoltage trip for dangerous machines (conforming to INRS) on GV2 ME only
1/L1
05
08 06
3/L2
54
5/L3
D1
Short-circuit signalling
Trip signalling
D2
E2
2/T1
4/T2
6/T3
E1
72
52
51
22
21
2/T1
Schemes
Motor circuit-breakers
GV3 ME
1/L1 3/L2 5/L3
GV3 A02
13 23
GV3 A03
13 23 31
GV3 A05
13 23 33
GV3 A06
13 23 33
GV3 A07
23 24 13 31
14
24
32
14
24
34
14
24
34
22
2/T1
4/T2
6/T3
Voltage trips
GV3 A09
97
GV3 B
D1
GV3 D
C1
D2
Motor circuit-breakers
GV7 R
1/L1 3/L2 5/L3
96
98
C2
12
92
14
94
11
91
81
2/T1
4/T2
6/T3
A self-adhesive label, supplied with the contact, can be affixed to the front face of the circuit-breaker to allow personalised marking according to the function of the contact or contacts. (1) See pages 20 and 59. GV7 ASppp
C1
Electric trips
GV7 AUppp
D1
97
50 ms
D4
C2
98
97
97
KA1 14
13
50 ms
50 ms
Reset
98
98
23
Reset
KA1 A1 22 A1 B1
24
A2
Associated components KA1: CAD + LAD 6K10 or RHK KM1: LC1 D or LC1 F
A2
KA1
Overload fault
KA1
KM1
21
21
24
22
14
14
14
24
73
32
Dimensions, mounting
GV2 L
Dimensions GV AD, AM, AN, AU, AS
Block GV AD, AM, AN Block GV AU, AS
GV2 AK00
14 98 32
X1
89
45 44,5
15
82
X2
26
50
61
9,3
9,3 81 (1)
(1) Maximum
18 44,5
X1 Electrical clearance = 40 mm for Ue y 415 V, or 80 mm for Ue = 440 V, or 120 mm for Ue = 500 and 690 V. X2 = 40 mm.
Mounting
On rail AM1 DE200, AM1 ED200 (35 x 15) Panel mounted On pre-slotted mounting plate AM1 PA
AF1 EA4 35 5 55 5,5 45 1055 35 DZ5 ME8 GV2 AF02 DZ5 MB201 50 60 135 45 44,5 44,5 84 84 106 13,5 13,5 24 9,5 35 54
GV2 LE
Dimensions GV AD, AM, AN, AU, AS
Block GV AD, AM, AN Block GV AU, AS
GV AE
X1
15 10
89
45
12,5
X1
7,5
16
44 66
44,5
9,3
9,3 81 (1)
18
Mounting
On 35 mm 7 rail On panel with adapter plate GV2 AF02
15
44,5
c
c = 80 on AM1 DP200 (35 x 7.5) and 88 on AM1 DE200, ED200 (35 x 15)
84,5
4,2 35 35
74
50/60
65
65
1,5...5 53 133282 6 = =
Door cut-out
4x3,5 43
13
= = 54 =
Sets of busbars GV2 G445, GV2 G454, GV2 G472, with terminal block GV2 G05
a 3 18 l p
63
45
=
p 45 54 72 Number of tap-offs GV2 G445 GV2 G454 GV2 G472 6 269 314 404
54
75
Dimensions, mounting
l 89 98 116
l 134 152
GV3 L
Dimensions
(1)
X1 68
144
(2)
68
64
132
9 X1 136 55
18
X1 = Electrical clearance (ISC max) 40 mm for Ue < 500 V, 50 mm for Ue < 690 V
(1) Blocks GV AN pp , GV ADpp and GV AM11 (2) Blocks GV3 AUpp and GV3 ASpp
64
136
37,5
Note: Leave a space of 9 mm between 2 circuit-breakers: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible up to 40 C.
80
3 92.5
4 101
76
Schemes
GV2 LEpp
1/L1 3/L2 5/L3
GV3 Lpp
1/L1 3/L2 4/T2 5/L3 6/T3 97 98
2/T1
4/T2
6/T3
2/T1
Accessories
Front mounting add-on contact blocks Instantaneous auxiliary contacts
GV AE1
OR
GV AE11
13 21
GV AE20
13 23
4/T2
6/T3
13
11
2/T1
97
14
22
14
14
12
24
23
98
Side mounting add-on contact blocks Instantaneous auxiliary contacts and fault signalling contacts
GV AD0110 GV AD0101 GV AD1010 GV AD1001
95
53
95
51
97
53
97
96
96
52
98
54
54
98
GV AN20
(63) 33 43 (73)
(62) 32
44 (74)
(64) 34
44 (74)
Voltage trips
GV AUppp GV ASppp
D1
D2
GK2 AX20
13 23
C2
C1
GK2 AX50
13 21
14
05
08 06
14
14
GK2 AX22
97 07
24
GK2 AX52
97 05
98
98
08
98
06
22
52
51
24
22
21
77
References
Enclosed thermal-magnetic motor circuit-breakers GV2 ME and accessories, for customer assembly
References
Thermal-magnetic motor circuit-breakers GV2 ME For motor circuit-breakers and accessories: see pages 47, 55 and 63. Starters consisting of a GV2 ME motor circuit-breaker in an enclosure conform to standard IEC 60947-4-1.
GV2 Ithe in enclosure (A) ME ME ME 01 02 03 0.16 0.25 0.4 ME ME 04 05 0.63 1 ME 06 1.6 ME 07 2.5 ME 08 4 ME 10 6.3 ME 14 9 ME 16 13 ME 20 17 ME 21 21 ME 22 23
500277_1
GV2 MC
IP 41 IP 55
500280_1
1 1 1 1
GV2 MP
500278_1
Front plate
Description For direct control, through a panel, of a chassis mounted GV2 ME IP 55 Reference GV2 CP21 Weight kg 0.800
Weight kg 0.075
GV2 K011 GV2 K021 GV2 K031 GV2 K04 (3) GV2 E01 GV2 E02
IP 55 IP 55 for < + 5 C
10 10
100
AB1 VV635UBL
0.015
50
AB1 AC6BL
0.003
(1) Enclosure GV2 MCK04 is fitted with a GV2 K04 mushroom head Emergency stop pushbutton as standard. (2) Supplied with IP 55 sealing kit. To be fitted with enclosure GV2 Mp01. (3) Padlockable in O position using 4 to 8 mm shank padlocks.
78
References dimensions
References (continued)
Thermal-magnetic motor circuit-breakers GV3 P For motor circuit-breakers and accessories: see pages 48 and 57. GV3 P40: operational current in enclosure limited to 30 A. Starters consisting of a GV3 P motor circuit-breaker in an enclosure conform to standards IEC/EN 60947-4-1 and IEC/EN 60947-2. Metal enclosures fitted with a padlockable rotary handle (1) , for thermal-magnetic circuit-breakers GV3 P, up to 30 A
Composition (2)
. TRIP
T RESE
510568
Type
b Metal enclosure, b Black handle GV2 AP01 Padlocking in ON/OFF position b Circuit-breaker/handle adapter GV3 PC02 b Metal enclosure, b Red handle GV2 AP02 Padlocking in OFF position b Circuit-breaker/handle adapter
Surface mounting
Weight
kg 2.000
Surface mounting
IP 65 IK 09
GV3 PC02
2.000
(1) For special applications a GV3 L magnetic motor circuit-breaker can be fitted in this type of enclosure. Please consult your Regional Sales Office. (2) Components for customer assembly. Circuit-breaker to be ordered separately.
Dimensions
7,7
312
150 203,5
181
52,5 52,5
97,5
97,5
79
References
Type
Degree of protection
GV2 MC
IP 41 Surface mounting , double IP 55 1 insulated with protective conductor. Sealable cover IP 55 for 1 temperature < + 5 C
Possible number of Reference side-mounting auxiliary contact blocks on GV2 ME LH side RH side 1 1 GV2 MC01 1 GV2 MC02 or GV2 MCK04 (1) 1 GV2 MC03
Weight
Spring return (2) Mushroom head Emergency Latching (2) stop IP 55 pushbutton 40 mm, red
500279_1
1 Key release, key n 1 455 Turn to 1 release 1 10 IP 55 for temperature between + 5 C and + 40 C 10 IP 55 for temperature between - 20 C and + 40 C 100 50
GV2 K011 GV2 K021 GV2 K031 GV2 K04 (3) GV2 E01
Sealing kit
GV2 K011
GV2 E02
0.012
0.015 0.003
(1) Enclosure GV2 MCK04 is fitted with a GV2 K04 mushroom head Emergency stop pushbutton as standard. (2) Supplied with IP 55 sealing kit. To be fitted with enclosure GV2 Mp01. (3) Padlockable in Off position using 4 to 8 mm shank padlocks.
80
References (continued)
81
Dimensions, mounting
Dimensions
Surface mounting enclosure GV2 MC0p
(1) = 147 84 93 = =
(1) 4 knock-outs for 16 mm plastic cable gland or 16 mm conduit. Surface mounting enclosure GV2 MCK04
93
Mounting
Flush mounting enclosures GV2 MP0p (panel cut-out)
GV2 MP0 p GV2 MP01, MP02 GV2 MP03, MP04 Front plate GV2 CP21
71 9,5 = = =
130
130
127
140
21
= 117 133 1...6 12 a
a 86
93,5 106,5
71 93
6,5
1...4 12
76 93
82
Schemes
Schemes
GV2 MEpp
1/L1 3/L2 4/T2 5/L3 6/T3
2/T1
GV AE11
GV AE20
11
13
13
21
13 14
14
12
14
22
95
53
95
51
97
24 53
23
97 98
98
96
96
54
52
54
GV AN20
(63) 33 43 (73)
(62) 32
44 (74)
(64) 34
44 (74)
Voltage trips
GV AUppp GV ASppp GV AXppp
D1
D1
D2
C2
C1
E1
Wiring diagram for undervoltage trip used on potentially dangerous machines, conforming to INRS
10 AgG max
1/L1
3/L2
5/L3
D1
D2
E2
2/T1
4/T2
6/T3
E1
E2
D2
05
52
51
83
Characteristics, references
Characteristics (1)
Conforming to standards Degree of protection conforming to IEC 60529 Operational voltage Ue Material IEC 60947-4, IEC 60439-1, VDE 0660-102 and EN 60947 GV2 LC: IP 547 GV NGC: IP 407 GV2 LC: 690 V GV NGC: 500 V Polycarbonate (2)
References
Control by black rotary handle, padlockable in Off position (up to 3 padlocks with 8 shank, to be ordered separately)
533740
Rating In
A 1.6
Breaking capacity Icu conforming to IEC 60947-2 220/ 400/ 440 V 230 V 415 V kA kA kA 100 100 100
500 V kA 100
Reference
Weight
kg 0.780
GV2 LC02pp
533741
2.5
100
100
100
100
13 In
0.780
100
100
100
100
13 In
0.780
6.3
100
100
100
100
13 In
0.780
10 GV2 LC02pp 14
100
100
20
10
13 In
0.780
100
50
20
10
13 In
0.780
18
533742
100
50
20
10
13 In
0.780
25
100
50
30
15
12 In
GV NGC0225
2.450
32
100
50
30
15
12 In
GV NGC0232
2.450
40
100
50
30
15
12 In
GV NGC0240
2.450
50
100
50
30
15
12 In
GV NGC0250
2.450
GV NGC02 pp
63
100
50
30
15
12 In
GV NGC0263
2.450
Variants
Starters with control by red rotary handle on yellow background
Add the letter R to the references selected above. Example: GV2 LC0206 becomes GV2 LC0206R.
GV2 LC02
(1) Circuit-breaker characteristics: GV2 L: see pages 14 and 15. NG 125L: product marketed under the Merlin Gerin, brand, please consult your Regional Sales Office. (2) Avoid placing this material in contact with harsh substances (detergents, chlorine solvents, ketones, alcohol, aromatic hydrocarbons). (3) The following can be fitted by the customer: a GVAD or GVAM auxiliary contact block on the LH side and a GVA p trip on the RH side. Scheme : page 85
Dimensions : page 85
84
Dimensions, scheme
Dimensions
GV2 LC0206LC0220 GV NGC0225NGC0263
= 348 237 186,3
At bottom ISO 2 x 20 or 2 x 25 2 x 20 or 2 x 25 or 2 x 32 or 2 x 40
65
150
166
120 173
= 88
Scheme
1/L1 3/L2 5/L3
2/T1
References : page 84
4/T2
6/T3
167
330
85
Substitution table
Reference
GV2 P06 GV2 P07 GV2 P08 GV2 P10 GV2 P14 GV3 P13 GV3 P18 GV3 P25 GV3 P32 GV3 P40 GV3 P50 GV3 P65
Ir
11.6 A 1.62.5 A 2.54 A 46 A 610 A 913 A 1218 A 1725 A 2332 A 3040 A 3750 A 4865 A
Icu / 400 V
> 100 kA > 100 kA > 100 kA > 100 kA > 100 kA 100 kA 100 kA 100 kA 100 kA 50 kA 50 kA 50 kA
100 kA 35 kA
GV3 ME63
35 kA
Reference
GK3 EF40
Icu / 400 V
50 kA
Reference
GV3 L25 GV3 L32 GV3 L40 GV3 L50 GV3 L65
Ie
25 A 32 A 40 A 50 A 65 A
Icu / 400 V
100 kA 100 kA 50 kA 50 kA 50 kA
GK3 EF65
35 kA
86
Operator dialog
Automation
Motor control
Power supplies
A worldwide presence
Constantly available b More than 5 000 points of sale in 130 countries. b You can be sure to find the range of products that are right for you and which complies fully with the standards in the country where they are used. Technical assistance wherever you are b Our technicians are at your disposal to assist you in finding the optimum solution for your particular needs. b Schneider Electric provides you with all necessary technical assistance, throughout the world.
www.telemecanique.com
Due to evolution of standards and equipment, the characteristics indicated in texts and images of this document do not constitute a commitment on our part without confirmation. Design: Schneider Electric Photos: Schneider Electric Printed by:
ART. 818220
09/2006
DIA1ED2060503EN
Simply Smart !