You are on page 1of 2

Muhammad Asif Naseer

Instrument Technician __________________________________________ OBJECTIVE: To pursue my career in a competitive industrial environment where I can apply my experiences and skills to the best of my abilities. EDUCATION: DAE (Electronics) EXPERIENCE: (15 Years) PBTE Lahore

PAK American Fertilizers Ltd. Pak-American Fertilizer Ltd. a Unit of AZGARD 9 consists of Ammonia Plant Kellogg process having capacity of 600 MTPD and Urea Plant TOYO Engineering Corporation having capacity of 1050 MTPD with ACES Technology Senior Technician Instrument (From 1997 till date) Job Responsibilities Implementation of Preventive maintenance schedule. Installation, maintenance and calibration of field instruments i.e Transmitters, Control Valves, RTDs, Thermocouples & level switches. Total loop check from field to CCR. Installation of DCS system (Marshalling Racks, Consoles, turbine Compressor panels) Planning of ATA jobs. Termination of cables along with continuity and megger test. Sound knowledge and understanding of DCS and PLC. Involved in loop checking, commissioning, and trouble shooting of control loops. Worked on the compressor control system, vibration and speed control system. I have clear understanding of P&IDs and Loops drawings, and have handsome approach on field problems as well as workshop maintenance activities. Inspection of incoming material Special Assignments at online Analyzers Infrared Analyzer Rosemount USA model 865, 815. Involved in installation and commissioning of infrared analyzers. These analyzers are measuring CO, CO2 and CH4 in percentage and in PPM. Calibration with zero gas (99.99 % N2) and standard gas(Span Gas) is normally carried out once per week.. Performed troubleshooting and rectified various day to day analyzer problems. Gas Chromatograph ABB, USA model vista 3100. Installation, commissioning and maintenance of Gas Chromatograph analyzer. This analyzer is measuring CH4, N2, H2, Ar and NH3. Performed troubleshooting and rectified various day to day analyzer problems. Moisture Analyzer(Panametrics) Range is 0~10ppm. Cleaning of detector is carried out in six months .

PH Meter DKK Installation, commissioning and maintenance of PH meter. Varian GC 450 Recently I installed Varian GC 450 with vendors in our shift lab, for the analysis of fuel & process gases. We used Helium gas as a carrier. Shimadzu GC I also coordinate with shift lab Shimadzu Gas Chromatograph which has Helium as a carrier gas and also maintenance with them. Most of the time we regenerated molecular sieve column. Oxygen Analyzer (Thermox 2000) It works on Zirconium Oxide principle. Instrument air is used as span gas 20.91% Zero gas is 0.15%. Sensor cleaning carried out every six months. Calibration is performed once per week. Range 0~5% Oxygen. Safety Conscious & Training Handsome safety awareness against personal safety as well as plant related safety. Maintain very safe working environment through the international standards. Got the safety trainings on specific safety topics like Advance Fire Fighting, Emergency First Aid, Fathers Name: NIC: Date of Birth: Domicile: Contact Numbers: Job Address: Ch. Naseer Ahmad 37406-1650779-5 October 10, 1975 Rawalpindi (Punjab) + 92-300-5497958 Pak American Fertilizers Ltd.Iskanderabad, Distt.Mianwali (Punjab ), Pakistan W-77/3, Chaghi Block, CPO Box # 177 Gulshon Colony Taxila. asif.gujjar1@yahoo.com

Address: Email Address:

You might also like