You are on page 1of 2

Holding "KABLOVI" a.d.

FKS TKL JAGODINA Serbia

No.

2207/09

TECHNICAL DATA

Version

1 Page 1 of 2

PE INSULATED SIGNALLING CABLES


WITH ARMOURING AND PE SHEATH Type Standard Application

A-2Y2YB2Y
According to specification ZJ S2.011-VDE 0816 and this Technical Data These cables are used as railway cables and can be installed into the ground or in duct Temperature range: during operation -40 to +60 C; during installation -10 to +60 C CABLE STRUCTURE Bare copper wire Polyethylene (PE) type 2YI1 acc. VDE 0207 Cores stranded in concentric layers Several plastic strip layers with overlap Polyethylene (PE) type 2YM1 acc. VDE 0207 One layer of galvanized steel tape (0,2 or 0,3 mm), helicoidally applied with gap Polyethylene (PE) type 2YM1 acc. VDE 0207, black GEOMETRICAL CHARACTERISTICS & DIMENSIONS

Conductor Insulation Stranding Core wrapping layer Inner sheath Armouring Protective outer sheath

Conductor diameter No. of core Inner sheath thickness, min. Thickness of steel tape, nom. Outer sheath thickness, nom. Outer diameter of cable, approx. Copper weight, approx. Weight, approx. Delivery length 10% Drum size (diameter/width) Gross mass per drum, approx.

mm mm mm mm mm kg/km kg/km m m kg 4 1,6 0,2 1,8 12,0 24 152 1000


1,0/0,7

6 0,8 0,2 1,8 11,5 35 160 1000


0,9/0,6

10 0,8 0,3 1,8 13,6 58 236 1000


1,0/0,7

12 0,8 0,3 1,8 14,0 70 247 1000


1,0/0,7

0,9 16 0,8 0,3 1,8 15,0 99 323 1000


1,0/0,7

20 0,8 0,3 1,8 16,0 129 390 1000


1,2/0,8

24 0,8 0,3 1,8 17,5 142 413 1000


1,2/0,8

30 0,8 0,3 1,8 18,5 177 473 1000


1,2/0,8

40 1,2 0,3 2,0 22,0 242 650 500


1,2/0,8

250

255

330

345

420

550

575

635

485

GEOMETRICAL CHARACTERISTICS & DIMENSIONS Conductor diameter No. of cores Inner sheath thickness, min. Thickness of steel tape, nom. Outer sheath thickness, nom. Outer diameter of cable, approx. Copper weight, approx. Weight, approx. Delivery length 10% Drum size (diameter/width) Gross mass per drum, approx. mm mm mm mm mm kg/km kg/km m m kg 50 1,2 0,3 2,0 23,5 292 730 500
1,2/0,8

0,9 60 1,2 0,3 2,0 24,5 367 876 500


1,2/0,8

1,4 80 1,2 0,3 2,0 27,0 480 1073 500


1,2/0,8

70 1,2 0,3 2,0 26,5 408 942 500


1,2/0,8

90 1,2 0,3 2,0 28,5 540 1187 500


1,4/0,9

100 1,2 0,3 2,2 30,5 580 1257 500


1,4/0,9

10 0,8 0,3 1,8 16,5 142 366 1000


1,2/0,8

12 0,8 0,3 1,8 17,0 172 625 1000


1,2/0,8

525

600

630

700

820

855

525

625

Date: 22.07.2009.

Signature: . Rakovi, dipl.el.in

Holding "KABLOVI" a.d. FKS TKL JAGODINA Serbia

No.

2207/09

TECHNICAL DATA

Version

1 Page 2 of 2

ELECTRICAL CHARACTERISTICS conductor diameter Conductor resistance, max. Insulation resistance, min. Mutual capacitance at 800 Hz, max. Test voltage, AC, 50 Hz, duration 1 min conductor conductor conductor - armour mm /km Gkm nF/km V 0,9 28,9 10 100 2500 2500 1,4 11,9 10 120 2500 2500

COLOR CODE & CABLE CORE LAY-UP First core in outer layer red First core in other layer blue Remaining cores of the layers gray
No. of cores 4 6 10 12 16 20 24 30 40 50 60 70 80 90 100 Center 4 PE cord 2 3 5 1 2 4 1 4 1 2 4 1 2 1st 6 8 9 11 6 8 10 7 10 6 8 10 6 8 2nd 3rd 4th 5th

Color code

Cable core lay-up

13 14 16 13 15 12 14 16 12 14

19 21 18 20 22 18 20

23 26 28 24 25

29 31

A-2Y2YB2Y 20 x 1 x 1,4 (principal drawing)


1 2 3 4 5 6

1. 2. 3. 4. 5. 6.

Copper conductor Conductor insulation (polyethylene) Cable core wrapping (plastic foil) Inner sheath (polyethylene) Armour (one galvanized steel tape) Outer sheath (polyethylene)

Date: 22.07.2009.

Signature: . Rakovi, dipl.el.in

You might also like