You are on page 1of 11

1958 Permanent Location/Address City or Town Country LAHORE Pakistan

Nationalitiy Pakistan Experience Classification

Job Function Electrical Engineers Job Industry Engineering Utilities


Qualifications Highest Qualifications Degree

Years Experience 23 Years Experience Not specified. 23

Qualification Subject Establishment/Country Year Degree ELECTRICAL ENGINEER NED UNIVERSITY KARACHI, PAKISTAN 1986
Other Qualifications, Memberships, Certifications PAKISTAN ENGINEERING COUNCILE IEEE USA Computer Skills and Software Used

CV Testing and Commissioning Manager

Name Tariq Mehmood Chaudhry ________________________________________ Current Location PRESENTLY I AM WORKING WITH AREVA IN CONGO ON Eni REVAMPING OF CONGO GRID PROJECT, AND RESPONSIBLE FOR THE TESTING & COMMISSIONING OF 220KV SUBSTATIONS, FOR COMPLETE ENERGY AUTOMATION. City Al-Jubail State KSA

Country Saudiarabia ________________________________________Permanent Home Address State City 238 Umar Block, Allama Iqbal Town Lahore Country Pakistan

________________________________________ Language English, Urdu Ability Read, write and speak fluently ________________________________________ Nationality By Birth Pakistani ________________________________________Experience Classification

Years of Experience Number of Employers 23

3 ________________________________________Qualifications Highest Qualification Bachelor of Engineering ELECTRONICS Subject Establishment/Country Year GPA BE Electrical (Major electronics) NED university of engineering & technology Karachi, Pakistan 1986 3.73 ________________________________________ Professional Trainings WAPDA ONE YEAR INDUCTION TRAINING. FOURE WEEKS PROTECTION COURSE AT TSG TRAINING INSTITUTE LAHORE, PAKISTAN. AREVA PROTECTION COURSE. SIEMENS ONE MONTH ON JOB TRAINING IN RELAY MANUFACTURING FACTORY, BERLIN, GERMANY SIEMENS ONE WEEK TRAINING COURSE IN TRAINING CENTER NEURANBERG, GERMANY MANY SMALL TRAININGS/SEMINARS ATTENDED. AutoCAD and all common operating software. ________________________________________Availability Earliest Start Date Given 4 weeks notice Are you willing to move or relocate? Yes ________________________________________Ideal Next Job Project Manager {protection and control (Testing & Commissioning)-Electrical} position with married status. ________________________________________Required Salary & Conditions Minimum 4500 per month in gulf countries + family status + transport + medical. By negotiation only for other than gulf countries.

________________________________________ PROFESSIONAL WORKING EXPERIENCE March, 2009 to till date Lead Commissioning Engineer Electrical (Contract) For : AREVA COGILEX FRANCE MARAFIQ POWER PROJECT, AL-JUBAIL Client: SAUDI ELECTRIC COMPANY Responsible for: Testing and commissioning of protection relays used on 380KV transmission lines for four circuits. Communication Checking between remote end devices regarding line differential and distance protection. Verification of Control wirings and Primary, secondary equipment connections with drawing. Commissioning two 986 Ah 125 volt dc bettry banks. Testing & commissioning of distribution transformers. November, 2007 to December 2008. Commissioning protection Engineer (Contract) For : MAM DUBAI 33/11KV Substation Projects DIBBA AND AL-FUJIRAH SUBSTATIONS. Client: Federal Electricity and Water Authority ( FEWA) UAE. Responsible For: Verification and testing of connections on secondary equipments, and Control Wiring Check with drawing. Circuit modification with help of drawing. Testing of ABB Protection relays - REF 542 +, SPAJ 115, SPAU, Areva Auxiliary relays, VATECH - ARGUS RELAYS, Solker RF, Solker Guard and test document Preparation. Testing of cable pilot wire differential (End to end test). Transformer Differential and Restricted Earth Fault Stability test and test Document Preparation. Scada signal interfacing up to RTU and commissioning of NCC signals with Scada Engineers. Power transformer complete testing and commissioning of parallel operation with TAPCON. November, 2004 to November, 2007. Deputy Manager T&D SIEMENS Lahore, Pakistan. Later as incharge of BU EA PTD Lahore Client: WAPDA, IPPs, AND INDUSTRIES Responsible For: . Relay and control panels testing during client's inspection. . Erection, testing and commissioning of AIS 132kv substations. . Testing and commissioning of 220 KV & 500 KV substations AIS and GIS. . All range of SIEMENS protective relays, main Areva & ABB relays. . Siemens Monitoring and Control devices. Cable Schedule/Terminal Connection diagram Verification and Modification if Changes required. Testing of 132KV/33KV Primary Equipments and test document Preparation. Circuit Breaker with Isolator, Isolator with Earth Switch Interlock Verification as per Drawing from Control Panel. Circuit Breaker, Isolator Status Checking and Interlock Verification through PLC. Control Scheme and Protection Scheme Verification with drawing. Stability test for Transformer Differential and REF Protection and test document Preparation. September 2001 to November 2004 Posted as system protection engineer (AD) in the office of chief engineer system protection wapda. Then attached with MD T&G as staff officer for the completion of few disputed works and assigned the duty to complete the work of 220KV Sibbi substation with in six months. This was commissioned in time and Chairman Wapda Awarded me cash award WITH COMMENDATION CERTIFICATE. All protection schemes completed by me after the partial commissioning by contractor. Responsible For: After two years CE SP called me back and assigned me the responsibility to check the drawings & design of 500/220KV substations & Transmission Lines submitted by contractors for vetting on turn key projects. Inspections of material, design, drawings, erection, testing & commissioning support to WAPDA construction engineers managed by

its own resources. Commissioning Schedule Preparation, Discussion with Chief Engineers Meeting regarding outstanding activities and execute the job with four junior Engineers. Circuit Breaker with Isolator, Isolator with Earth Switch Interlock Verification as per Drawing from Local Cubicle and Remote Control Panel. Review all Pre Commissioning Activities and test documents. Assign the testing activities to junior engineers for testing the Power transformer, Circuit breakers and auxiliary relays and test document verification. Final and overall Checks for Tripping to the Circuit breaker like, O/C& E/F, Breaker failure, Bus bar differential, Transformer differential, upstream/ downstream, Line Protection etc.., Stability test for Transformer Differential and REF Protection and test document Preparation. March 1998 to August 2001 Lead Protection & Instrumentation Engineer Electrical 500 KV grid station Lahore, Pakistan. Nature of Job: My working responsibility was to look after all protection and control circuits fault and trouble shootings, their rectifications, annual testing of protection relays / monitoring devices. The scheme verifications and coordinated the work of three new 220 KV bays with responsibility of shut downs and restoration of supply. Design Co-ordination for Existing substation and modification works. December 1995 to March 1998 SUB DIVISIONAL OFFICER IESCO ISLAMABAD, PAKISTAN Responsible For: To deal with new connections, feasibilities for new industrial consumers, cable laying, jointing, and new feeders up to 11kv. Supervision of the contractors during construction of new substation with in IESCO and witnessing of their testing and commissioning works. Attend the meeting as with Chairman Area Electricity Board, Chief Engineers, Discussion regarding Week Schedule/Monthly Schedule Program for Primary/Secondary Equipment testing activities, Control Checks, any design modification and any engineering quires. Testing of CT, CVT, SF6 Circuit Breaker, Power transformer, test documents. Bay Interlock Verification as per Schematic diagram for breaker with Isolator and Isolator with Earth Switch from remote Control panel and local Cubicle. Control Checks for CB Closing/Tripping circuit, Power Transformer Alarm/Trappings and other Controls with drawing and LVAC Board CB manual operation and auto Change over Checks using temp. Supply. All type of AREVA made Auxiliary relays and K-Series Relays testing and test document Preparation. Stability test for Transformer Differential and REF Protection. January 1990 to November 1995 SUB DIVISIONAL OFFICER GC-2 PD GSC RAWALPINDI, PAKISTAN Posted as sub-divisional officer (SDO-GC-11) in the department of Grid System Construction, RWP. During this period my responsibilities were manage the project of construction of 220/132/66/33KV substations along with additional augmentation works of the 220/132/66/33KV substations. In this session, I also got the opportunity to work in the Testing & Inspection department of Grid System Construction directorate, Rawalpindi. Where, I performed the testing and commissioning work of 220/132/66/33kv substations. Responsible for: The complete construction of control building, equipment erection, testing and commissioning using wapda own working team and testing equipments, both on primary and secondary sides. Panel wiring Checks as per drawing, red marking if required and maintaining three set of drawings. October 1988 to January 1990 RESIDENT ENGINEER SUB-STATION AND TRANSMISSION LINES, MIANWALI UNDER CHIEF ENGINEER GSO ISLAMABAD Responsible for: The management, execution of the operations and complete maintenance of five 132kv substations and thirteen 66kv substations. Trouble shooting of transmission lines faults for huge network of 66KV, 132KV and 220kv transmission lines. Also the rectification of faults and annual preventive maintenance of the substations and transmission lines by trained TL crew of wapda. Testing of all protection and monitoring devices and protection scheme verifications in substations. Providing direction to testing engineers for primary equipment testing and test document implementation. Auxiliary relays, Electromagnetic type OC, EF (Dir, Non dir) relays testing and test document preparation Control Checks for CB Closing/Tripping circuit, Power Transformer Alarm/Trip Signals and other Controls with drawing. Bay Interlock Verification as per diagram for breaker with Isolator and Isolator with Earth Switch. Auto Reclosure Scheme Checking for Line breakers and tie breakers with protection drawing.

July 1987 to September 1988 On induction trainings from WAPDA training centers for all departments regarding engineering and management. DERING MY WORKING EXPERIENCE I DID WORK ON:ABB Relays Operating Software CAP540, PCM600, CAP316, REF542+ Configuration Tool Fupla Siemens Software Digsi 4.7 and all old versions Areva Software- Micom and Studio S1 GE- Enervista 489 Setup. Testing Equipments Known to Operate Omicron CMC 156/256 Omicron CPC 100 Sverker 650/750, ABB XS92a ODEN - Three Phase Primary injection kit CT Analyzer- Omicron Programma TM1600 Breaker Analyzer System Programma MOM200A - Micro ohm meter Magnus Metriso 5000, Megger BM15 Insulation Tester, Muliamps all range and many other test kits. Relays Known to Test Numerical Relays ABB Make RED670, RET670, REB670 ,REX521, RET316, REL551, RET531, REF542+, SPAJ, SPAU, SPAD, SPAM SIEMENS Make 7SJ61, 7SJ62, 7SD61, 7RW600, 7UT613 AREVA Make - P122, P127, P922, P643, MOTPRO, KCGG142, KCEG142, KVFG142, KBCH120 VATECH - ARGUS RELAYS, Solker RF, Solker Guard CPR97 (TRENCH) Capacitor Bank Protection General Protection Protection Function 50, 51 Phase Over Current Relays 50N, 51N Phase Earth Fault Relays 67,67N Directional OC & EF Protection 87T Transformer Differential Protection 87L Line Differential Protection 87N Restricted EF Protection 49 Thermal Overload Protection Electromagnetic Relays ABB Make - RADSB, RADHD, RADHA, RAICA AREVA - MCCG, MCAG, CDG, CDD, SKD, SKE, MVTP, MVAG, MVAJ, VAA, VTT, VAJM, VDG (ENGLISH ELECTRIC, GEC ALSTOM, ALSTOM) Primary equipment Known to Test Current transformer up to 500/220/132/110/66/33/11KV Voltage Voltage transformer up to 500/220/132/110/66/33/11KV Circuit Breaker up to 500/220/132/110/66/33/11KV Power Transformer up to 200MVA single phase and BANK, three phase up to 160MVA Primary Test Known to Check Stability/Sensitivity Test for Transformer Differential/Restricted Earth fault Protection Stability/Sensitivity Test for Bus bar Differential Protection Stability/Sensitivity Test for Line Differential Protection end to end test. High Voltage test for Primary Equipment Key Skills Systematical planning Schedule Preparation for Primary/Secondary equipment testing activities and precommissioning activities. Primary/Secondary electrical equipment testing, using various type of test equipment and test document Preparation. Control Scheme (Isolator and Circuit Breaker)/ Protection Scheme (Breaker failure, Bus bar Protection, Transformer differential Protection, Load Shedding, Line differential-end to end test, distance protection) Checking with Schematic diagram and Automatic Switchover Function checking in 0.415KV LVAC Board. Electrical/ Mechanical Interlock Verification for Circuit breaker with Isolator and Isolator with Earth Switch as per diagram.

Vendor Document review for Electrical Primary/ Secondary Equipment FAT report. SAT Report Preparation/Verification and Method of statement Preparation for Commissioning. Attend the meeting as a lead engineer with Client, Discussion regarding testing/Pre-Commissioning Activities (Planning Schedule) and clarification for any engineering Quires. Primary and Secondary equipment testing with Client/Consultant and answer for all engineering quires, and Working experience with multinational environment. Successfully Commission the Substation, Power Project with in the Schedule time Last Modified: JAN, 2010 ________________________________________-- End of CV--

Work Locations Are you willing to move or relocate?

Yes - I will travel domestically Yes - I will relocate domestically Yes - I will travel internationally Yes - I will relocate internationally Availability

Start Immediately? Not available now. Ideal Next Job excluding IRAQ, AFGHANISTAN. ALL OTHER Required Salary & Conditions NOT LESS THAN 9000 USD PER MONTH Employment History

Total Years of Work Experience Commenced Full Time Work 26 1987 Last/Current Employer

Job Title Duration Elect Engineer From :01-Jan-1987 To: 01-Jan-2004 Summary PLEASE REFER TO MY CV. Work Experience

CV Testing and Commissioning Manager

Name Tariq Mehmood Chaudhry ________________________________________ Current Location PRESENTLY I AM WORKING WITH AREVA IN CONGO ON Eni REVAMPING OF CONGO GRID PROJECT, AND RESPONSIBLE FOR THE TESTING & COMMISSIONING OF 220KV SUBSTATIONS, FOR COMPLETE ENERGY AUTOMATION, City Al-Jubail State KSA Country Saudiarabia ________________________________________Permanent Home Address State City Country Pakistan

________________________________________ Language English, Urdu Ability Read, write and speak fluently ________________________________________ Nationality By Birth Pakistani ________________________________________Experience Classification

Years of Experience Number of Employers 23

________________________________________Qualifications Highest Qualification Bachelor of Engineering ELECTRONICS Subject Establishment/Country Year GPA BE Electrical (Major electronics) NED university of engineering & technology Karachi, Pakistan 1986 3.73 ________________________________________ Professional Trainings WAPDA ONE YEAR INDUCTION TRAINING. FOURE WEEKS PROTECTION COURSE AT TSG TRAINING INSTITUTE LAHORE, PAKISTAN. AREVA PROTECTION COURSE. SIEMENS ONE MONTH ON JOB TRAINING IN RELAY MANUFACTURING FACTORY, BERLIN, GERMANY SIEMENS ONE WEEK TRAINING COURSE IN TRAINING CENTER NEURANBERG, GERMANY MANY SMALL TRAININGS/SEMINARS ATTENDED. AutoCAD and all common operating software. ________________________________________Availability Earliest Start Date Given 4 weeks notice Are you willing to move or relocate? Yes ________________________________________Ideal Next Job Project Manager {protection and control (Testing & Commissioning)-Electrical} position with married status. ________________________________________Required Salary & Conditions Minimum 4500 per month in gulf countries + family status + transport + medical. By negotiation only for other than gulf countries.

________________________________________ PROFESSIONAL WORKING EXPERIENCE March, 2009 to till date Lead Commissioning Engineer Electrical (Contract) For : AREVA COGILEX FRANCE MARAFIQ POWER PROJECT, AL-JUBAIL Client: SAUDI ELECTRIC COMPANY Responsible for: Testing and commissioning of protection relays used on 380KV transmission lines for four circuits. Communication Checking between remote end devices regarding line differential and distance protection. Verification of Control wirings and Primary, secondary equipment connections with drawing. Commissioning two 986 Ah 125 volt dc bettry banks. Testing & commissioning of distribution transformers. November, 2007 to December 2008. Commissioning protection Engineer (Contract) For : MAM DUBAI 33/11KV Substation Projects DIBBA AND AL-FUJIRAH SUBSTATIONS. Client: Federal Electricity and Water Authority ( FEWA) UAE. Responsible For: Verification and testing of connections on secondary equipments, and Control Wiring Check with drawing. Circuit modification with help of drawing. Testing of ABB Protection relays - REF 542 +, SPAJ 115, SPAU, Areva Auxiliary relays, VATECH - ARGUS RELAYS, Solker RF, Solker Guard and test document Preparation. Testing of cable pilot wire differential (End to end test). Transformer Differential and Restricted Earth Fault Stability test and test Document Preparation. Scada signal interfacing up to RTU and commissioning of NCC signals with Scada Engineers.

Power transformer complete testing and commissioning of parallel operation with TAPCON. November, 2004 to November, 2007. Deputy Manager T&D SIEMENS Lahore, Pakistan. Later as incharge of BU EA PTD Lahore Client: WAPDA, IPPs, AND INDUSTRIES Responsible For: . Relay and control panels testing during client's inspection. . Erection, testing and commissioning of AIS 132kv substations. . Testing and commissioning of 220 KV & 500 KV substations AIS and GIS. . All range of SIEMENS protective relays, main Areva & ABB relays. . Siemens Monitoring and Control devices. Cable Schedule/Terminal Connection diagram Verification and Modification if Changes required. Testing of 132KV/33KV Primary Equipments and test document Preparation. Circuit Breaker with Isolator, Isolator with Earth Switch Interlock Verification as per Drawing from Control Panel. Circuit Breaker, Isolator Status Checking and Interlock Verification through PLC. Control Scheme and Protection Scheme Verification with drawing. Stability test for Transformer Differential and REF Protection and test document Preparation. September 2001 to November 2004 Posted as system protection engineer (AD) in the office of chief engineer system protection wapda. Then attached with MD T&G as staff officer for the completion of few disputed works and assigned the duty to complete the work of 220KV Sibbi substation with in six months. This was commissioned in time and Chairman Wapda Awarded me cash award WITH COMMENDATION CERTIFICATE. All protection schemes completed by me after the partial commissioning by contractor. Responsible For: After two years CE SP called me back and assigned me the responsibility to check the drawings & design of 500/220KV substations & Transmission Lines submitted by contractors for vetting on turn key projects. Inspections of material, design, drawings, erection, testing & commissioning support to WAPDA construction engineers managed by its own resources. Commissioning Schedule Preparation, Discussion with Chief Engineers Meeting regarding outstanding activities and execute the job with four junior Engineers. Circuit Breaker with Isolator, Isolator with Earth Switch Interlock Verification as per Drawing from Local Cubicle and Remote Control Panel. Review all Pre Commissioning Activities and test documents. Assign the testing activities to junior engineers for testing the Power transformer, Circuit breakers and auxiliary relays and test document verification. Final and overall Checks for Tripping to the Circuit breaker like, O/C& E/F, Breaker failure, Bus bar differential, Transformer differential, upstream/ downstream, Line Protection etc.., Stability test for Transformer Differential and REF Protection and test document Preparation. March 1998 to August 2001 Lead Protection & Instrumentation Engineer Electrical 500 KV grid station Lahore, Pakistan. Nature of Job: My working responsibility was to look after all protection and control circuits fault and trouble shootings, their rectifications, annual testing of protection relays / monitoring devices. The scheme verifications and coordinated the work of three new 220 KV bays with responsibility of shut downs and restoration of supply. Design Co-ordination for Existing substation and modification works. December 1995 to March 1998 SUB DIVISIONAL OFFICER IESCO ISLAMABAD, PAKISTAN Responsible For: To deal with new connections, feasibilities for new industrial consumers, cable laying, jointing, and new feeders up to 11kv. Supervision of the contractors during construction of new substation with in IESCO and witnessing of their testing and commissioning works. Attend the meeting as with Chairman Area Electricity Board, Chief Engineers, Discussion regarding Week Schedule/Monthly Schedule Program for Primary/Secondary Equipment testing activities, Control Checks, any design modification and any engineering quires. Testing of CT, CVT, SF6 Circuit Breaker, Power transformer, test documents. Bay Interlock Verification as per Schematic diagram for breaker with Isolator and Isolator with Earth Switch from remote Control panel and local Cubicle. Control Checks for CB Closing/Tripping circuit, Power Transformer Alarm/Trappings and other Controls with

drawing and LVAC Board CB manual operation and auto Change over Checks using temp. Supply. All type of AREVA made Auxiliary relays and K-Series Relays testing and test document Preparation. Stability test for Transformer Differential and REF Protection. January 1990 to November 1995 SUB DIVISIONAL OFFICER GC-2 PD GSC RAWALPINDI, PAKISTAN Posted as sub-divisional officer (SDO-GC-11) in the department of Grid System Construction, RWP. During this period my responsibilities were manage the project of construction of 220/132/66/33KV substations along with additional augmentation works of the 220/132/66/33KV substations. In this session, I also got the opportunity to work in the Testing & Inspection department of Grid System Construction directorate, Rawalpindi. Where, I performed the testing and commissioning work of 220/132/66/33kv substations. Responsible for: The complete construction of control building, equipment erection, testing and commissioning using wapda own working team and testing equipments, both on primary and secondary sides. Panel wiring Checks as per drawing, red marking if required and maintaining three set of drawings. October 1988 to January 1990 RESIDENT ENGINEER SUB-STATION AND TRANSMISSION LINES, MIANWALI UNDER CHIEF ENGINEER GSO ISLAMABAD Responsible for: The management, execution of the operations and complete maintenance of five 132kv substations and thirteen 66kv substations. Trouble shooting of transmission lines faults for huge network of 66KV, 132KV and 220kv transmission lines. Also the rectification of faults and annual preventive maintenance of the substations and transmission lines by trained TL crew of wapda. Testing of all protection and monitoring devices and protection scheme verifications in substations. Providing direction to testing engineers for primary equipment testing and test document implementation. Auxiliary relays, Electromagnetic type OC, EF (Dir, Non dir) relays testing and test document preparation Control Checks for CB Closing/Tripping circuit, Power Transformer Alarm/Trip Signals and other Controls with drawing. Bay Interlock Verification as per diagram for breaker with Isolator and Isolator with Earth Switch. Auto Reclosure Scheme Checking for Line breakers and tie breakers with protection drawing. July 1987 to September 1988 On induction trainings from WAPDA training centers for all departments regarding engineering and management. DERING MY WORKING EXPERIENCE I DID WORK ON:ABB Relays Operating Software CAP540, PCM600, CAP316, REF542+ Configuration Tool Fupla Siemens Software Digsi 4.7 and all old versions Areva Software- Micom and Studio S1 GE- Enervista 489 Setup. Testing Equipments Known to Operate Omicron CMC 156/256 Omicron CPC 100 Sverker 650/750, ABB XS92a ODEN - Three Phase Primary injection kit CT Analyzer- Omicron Programma TM1600 Breaker Analyzer System Programma MOM200A - Micro ohm meter Magnus Metriso 5000, Megger BM15 Insulation Tester, Muliamps all range and many other test kits. Relays Known to Test Numerical Relays ABB Make RED670, RET670, REB670 ,REX521, RET316, REL551, RET531, REF542+, SPAJ, SPAU, SPAD, SPAM SIEMENS Make 7SJ61, 7SJ62, 7SD61, 7RW600, 7UT613 AREVA Make - P122, P127, P922, P643, MOTPRO, KCGG142, KCEG142, KVFG142, KBCH120 VATECH - ARGUS RELAYS, Solker RF, Solker Guard CPR97 (TRENCH) Capacitor Bank Protection General Protection Protection Function 50, 51 Phase Over Current Relays 50N, 51N Phase Earth Fault Relays 67,67N Directional OC & EF Protection 87T Transformer Differential Protection 87L Line Differential Protection

87N Restricted EF Protection 49 Thermal Overload Protection Electromagnetic Relays ABB Make - RADSB, RADHD, RADHA, RAICA AREVA - MCCG, MCAG, CDG, CDD, SKD, SKE, MVTP, MVAG, MVAJ, VAA, VTT, VAJM, VDG (ENGLISH ELECTRIC, GEC ALSTOM, ALSTOM) Primary equipment Known to Test Current transformer up to 500/220/132/110/66/33/11KV Voltage Voltage transformer up to 500/220/132/110/66/33/11KV Circuit Breaker up to 500/220/132/110/66/33/11KV Power Transformer up to 200MVA single phase and BANK, three phase up to 160MVA Primary Test Known to Check Stability/Sensitivity Test for Transformer Differential/Restricted Earth fault Protection Stability/Sensitivity Test for Bus bar Differential Protection Stability/Sensitivity Test for Line Differential Protection end to end test. High Voltage test for Primary Equipment Key Skills Systematical planning Schedule Preparation for Primary/Secondary equipment testing activities and precommissioning activities. Primary/Secondary electrical equipment testing, using various type of test equipment and test document Preparation. Control Scheme (Isolator and Circuit Breaker)/ Protection Scheme (Breaker failure, Bus bar Protection, Transformer differential Protection, Load Shedding, Line differential-end to end test, distance protection) Checking with Schematic diagram and Automatic Switchover Function checking in 0.415KV LVAC Board. Electrical/ Mechanical Interlock Verification for Circuit breaker with Isolator and Isolator with Earth Switch as per diagram. Vendor Document review for Electrical Primary/ Secondary Equipment FAT report. SAT Report Preparation/Verification and Method of statement Preparation for Commissioning. Attend the meeting as a lead engineer with Client, Discussion regarding testing/Pre-Commissioning Activities (Planning Schedule) and clarification for any engineering Quires. Primary and Secondary equipment testing with Client/Consultant and answer for all engineering quires, and Working experience with multinational environment. Successfully Commission the Substation, Power Project with in the Schedule time Last Modified: June 26, 2009 ________________________________________-- End of CV--

You might also like