Importing Nozzle Loads from AutoPIPE into AutoPIPE Nozzle

Applies To
Product(s): AutoPIPE, Version(s): 2004, XM, & V8i Environment: N/A Area: Import / Export Subarea: Original Author: Bentley Technical Support Group

Problem:
How to import loads from AutoPIPE into AutoPIPE Nozzle?

Answer:
Use the following procedure: Note: Before starting this procedure be sure that AutoPIPE (Advance or Nuclear) and AutoPIPE Nozzle are correctly installed and licensed. AutoPIPE Nozzle cannot be licensed with AutoPIPE Standard. 1. Open model in AutoPIPE, ex: C:\ Bentley\ AutoPIPE V8i SELECTseries \ Examples\ WALKTHRU.DAT 2. Tell AutoPIPE which anchors in the model are to be exported to AutoPIPE Nozzle: a. Grids: Open the Model Input grids (Edit> Grids), select the Anchor tab, in the very last column on the right place a check mark in the box for the

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__... 15/Oct/2013

Importing Nozzle Loads from AutoPIPE into AutoPIPE Nozzle - Pipe Stress and Vessel ...

Page 2 of 3

b. Anchor dialog: Place a check mark in the box "Report anchor results to AutoPIPE Nozzle"

3. Anlyze the model 4. Select File> Export> Nozzle Loads to AutoPIPE Nozzle. Note: See AutoPIPE online help for details about the this command and file format. 5. Providing everthing was installed correctly and licensed, in a few moments, AutoPIPE Nozzle should have automatically started. Note: If AutoPIPE Nozzle does not automatically start then starte the program and then select File> Import AutoPIPE... 6. On the "Import AutoPIPE Nozzles" dialog screen, " Select Nozzle PXF file" should have automatically been the filled in with the model name exported from AutoPIPE, ex: Walkthru User must press on the drop down arrows to choose BOTH a "Selct Nozzle ID" and a "Analysis Set Number", as pictured below, before pressing OK button.

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__... 15/Oct/2013

Importing Nozzle Loads from AutoPIPE into AutoPIPE Nozzle - Pipe Stress and Vessel ...

Page 3 of 3

After making a valid selection fro the 2 items above, press the OK button. 7. Choose a from 1 of 5 vessel "Orientation", and press OK button to complet the process of importing nozzle loads from AutoPIPE V8i. Note: AutoPIPE Nozzle can only process one nozzle at a time. When completed with the current nozzle, save the file, and then select File> Import AutoPIPE... to select a different nozzle ID to be processed.

See Also
Bentley AutoPIPE

External Links
Bentley Technical Support KnowledgeBase Bentley LEARN Server

Comments or Corrections?
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!

http://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__... 15/Oct/2013

You might also like