You are on page 1of 2

Fan coils with brushless motor

12

YARDY-I EV2
IN
Cooling capacity: 1.98.4 kW - Heating capacity: 2.511.8 kW

V GREEN IN LINE
ER T ER
f o r ve r

Consumption reduced by 50% when compared to traditional motors Continuous fan speed regulation Quieter operation Enhanced room comfort
Floor and ceiling, recessed or false ceiling fan coils with cabinet.
Construction features
Heat exchanger with nned coil with left-hand connections reversible to right. Centrifugal fan with an inverter-controlled brushless electronic motor and continuous speed adjustment. Version with covering cabinet structure made with pre-painted sheet metal complete with renewable lter, grilles made of ABS polymer and condensation drain pan with natural drainage. Galvanized sheet steel recessed structure, complete with condensation drain pan with natural drainage and renewable lter.

M OP-

t ic a

MO T l/ h o

SIO N S VEiR s t a ll a t i o n n P O t al
iz
on

HORIZONTAL installation VERTICAL


installation

Versions
MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for oor installation. MOP - Horizontal/vertical unit with cabinet equipped with rear air inlet and front ow for ceiling installation, wall mounting or with feet on ground. MOT - Horizontal/vertical unit with cabinet equipped with recovery unit lower air and front output for ceiling installation or oor installation. IVP - Recessed vertical unit equipped with lower air inlet and upper outlet for wall installation. IVF - Recessed vertical unit equipped with lower air inlet and front outlet for wall installation. IOP - Horizontal/vertical unit equipped with rear air inlet and front outlet for false ceiling or wall installation.

Valve and balancing valve. ON/OFF 2-way solenoid valves for 2 and 4-pipe systems. ON/OFF 3-way valves for 2 and 4-pipe systems. Auxiliary condensation drain pan. Manual damper. Motorised damper. Rear panel. Rear closure panel. Rear closure panel with grille and lter. Support feet with pipe cover. Frame with lter (G2) that can be extracted in any direction. Outlet straight connection. 90 outlet and inlet connection. Telescopic outlet/inlet connection. Inlet grille with lter. Outlet grille. Cover panel with grilles (only IUP). Flange for connection to duct. Antivibration connection for connection to the inlet or outletduct. Inlet/outlet plenum with circular nozzles.

CONTROLS

Wall-mounted remote control receiver with remote control. Electronic panel for wall or on board mounting. Wall-mounted recessed electronic panel.

For installation on machine.

ACCESSORIES

Additional water heating coil. Electric heater.

Master/slave electronic board, ON/OFF valve management module and electric heater, temperature probe for hot row. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory-mounted Supplied loose

Web code: WVYI Web code accessories: WAWB

13
Set Temperature (C)

WATER CHILLERS HEAT PUMPS WATER CHILLERS HEAT PUMPS


MVP-MOP for vertical installation MVT-MOT for vertical installation MVP-MOP+feet Data in the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 50C, ow rate as in cooling. Air: 20C - Water: 70/60C. At 1 m from air outlet with directionality factor of 2.

Inverter Traditional

Time (s)

mm mm mm mm mm mm Kg Kg

MOP for horizontal installation

MOT for horizontal installation

IVP-IOP for horizontal installation

IOP for vertical installation

IVF for vertical installation

TERMINAL UNITS

FAN COIL CONVECTORS SYSTEM ACCESSORIES

MAX MED MIN Heat capacity (50C) MAX MED MIN Heat capacity (70C) MAX Heat capacity MAX additional coil MED MIN Air flow rate MAX MED MIN Sound capacity MAX MED MIN Sound pressure MAX MED MIN Maximum consumed power MAX MED MIN Power supply SIZES AND WEIGHTS L - Width MOP-MOT-MVP-MVT L - Width IVP-IOP-IVF H - Height MOP-MOT-MVP-MVT H - Height IVP-IOP-IVF P - Depth MOP-MOT-MVP-MVT P - Depth IVP-IOP-IVF Weight MOP-MOT-MVP-MVT Weight IVP-IOP-IVF

kW kW kW kW kW kW kW kW kW kW m/h m/h m/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W W W V-ph-Hz

CONDENSING UNITS

EXP Polyvalent systems

INDUSTRIAL & PROCESS COOLING

YARDY-I EV2 MODEL Total cooling capacity

20 1.88 1.45 0.75 2.47 1.77 0.91 4.20 2.19 1.91 1.00 331 230 97 48 40 23 40 32 15 23.4 13.2 5.0 230-1-50 20 800 550 570 545 220 212 20 16.5

30 3.00 2.33 1.09 3.87 2.99 1.42 6.56 3.30 2.63 1.47 523 400 167 50 43 24 42 35 16 26.0 15.0 6.0 230-1-50 30 1.000 750 570 545 220 212 21 20.5

45 4.15 3.06 1.54 5.28 3.74 1.81 8.91 3.79 3.29 1.78 645 450 198 51 42 25 43 34 17 39.0 14.0 7.0 230-1-50 40 1.200 950 570 545 220 212 28 25.5

60 6.37 4.62 1.79 8.38 6.07 2.24 14.27 6.29 5.27 2.49 1,235 781 256 62 50 27 54 42 19 89.0 23.0 6.0 230-1-50 60 1.500 1.250 570 545 220 212 35 34.5

80 8.40 5.92 2.11 11.76 8.39 3.07 20.25 7.52 6.07 2.89 1,503 965 300 66 56 32 58 48 24 136.0 50.0 7.0 230-1-50 80 1.500 1.250 570 545 220 212 37 36.5

WATER-cooled CONDENSERLESS UNITS

WATER CHILLERS HEAT PUMPS

AIR-cooled CENTRIFUGAL fans

AIR-cooled AXIAL fans