Above and below ground drainage by Wavin

Soil & Waste Systems Product, Design and Installation Guide

Solutions for Essentials

Introduction

OSMA from Wavin


Wavin in the UK
Wavin Limited is the UKs leading supplier of water management,plumbing, heating and drainage systems for the Building, Construction and Utilities markets. Highly respected within the construction industry, Wavin has a reputation for innovation and leadership and has an extensive product portfolio under the OSMA, Hepworth, Hep2O, Thermoboard, Intesio and Certus brands.

Intelligent connections
OSMA systems offer integrated solutions. This enables specifiers and installers to assemble complete drainage, plumbing and heating, and pressure pipe systems from a single source, with complete confidence in compatibility and performance. All systems are backed by comprehensive technical support and a nationwide distribution network to ensure availability when and where required. RecycoreTechnology is Wavin's new and innovative manufacturing process developed to reduce the use of virgin materials in its products by using at least 50% recycled PVC-U content. Products that carry the RecycoreTechnology mark use as much recycled material as possible whilst still ensuring the same high performance and handling characteristics as the virgin products they replace. The products are quality assured, industry tested and Kitemarked where appropriate to help our customers meet increasingly demanding environmental commitments. All soil pipe in the Osma range are now manufactured utilising Wavins new RecycoreTechnology process.

Wavin Group
Wavin Limited is part of the Wavin Group, the leading supplier of plastic pipe systems and solutions in Europe. The company provides essentials: plastic pipe systems and solutions for tap water, surface heating and cooling, soil and waste, rain- and storm water, distribution of drinking water and gas and telecom applications. Wavin is headquartered in Zwolle (The Netherlands) and has a presence in 26 European countries, with manufacturing sites in 18 of those and one in China.

Environmental responsibility
Wavin Limited has BS EN ISO 9001: 2000 BSI status and was the first plastic pipe manufacturer to be accredited to ISO 14001: 2004 Environmental Management Systems. Wavin is committed to environmental responsibility, and is a leading pioneer of systems to conserve and control water. In production, the Company recycles the majority of waste materials, and sets annual targets for energy efficiency audited by the certifying body.

Quality assured products


OSMA systems are the benchmark for excellence and product innovation: precision-manufactured in the UK using the most advanced injection moulding and extrusion machines. All products comply with or exceed relevant British and European standards to ensure reliability and longlasting service.

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Contents

Range Introduction
Recycore OSMA Soil systems OSMA Waste systems OSMA Traps OSMA Condensate OSMA Overflow systems Estimating Data 45 6-7 8-12 11 11 12 13

ANCILLARIES and SPARES


Ancillaries Spares 82 82-83

SITEWORK Good Site Practice


Handling, storage, safety 103

DESIGN Design Procedures


System planning Typical Assembly Applications, pipe sizing Maximum pipe runs, thermal movement Pipe support, access, offsets 84 85 86 87-88

Installation Techniques
Pipe cutting and jointing 104-105 Pipe support and offsets 106 Connections to drainage 107 Access Saddle and WC Manifold 108 OSMA Fire Stop Seals 109 Connections to waste 110-111 OsmaVent Air Admittance Valves 112 Weatherproofing soil stack 113 Traps and shower gullies 114-115 Overflow 116-117 OSMA Breather Vent 117 OSMA Extract Valve 118 Maintenance, repairs, testing, safety 119

System Selector
Easy-to-view guide to system components and compatibility 14-15

OSMA SOIL SYSTEMS


PVC-U Ring-Seal Soil system: OsmaSoil 16-32 PVC-U Solvent Weld Soil system: OsmaSoil 3343 PVC-U Soil system: WC Connectors 4449 PVC-U Soil system: Vents 5052

Design Detailing
System connections Connections to drainage Connections to waste Connections to WC's WC Manifolds Specific design issues Ventilation Fire stopping Physical characteristics Materials: properties and performance 89-90 91-93 94-95 96-97 98-100 101

REFERENCE
General information Index Notes 120-121 122-124 125-126

OSMA WASTE SYSTEMS


ABS Solvent Weld Waste system: OsmaWeld PVC-C Solvent Weld Waste system PP Push-Fit Waste system Vents PP Waste system: V-Joint Traps Condensate Drainage system 5358 5961 6265 66 6774 7576

102

Advice and Technical Assistance

127

OSMA OVERFLOW SYSTEMS


ABS & PVC-U Solvent Weld Overflow System PP Push-fit Overflow system 7779 8081

Email: info@wavin.co.uk

www.osma.co.uk

Introducing new Recycore Soil Pipe

Same Performance Same Quality Better Environment


Recycore Technology is Wavins new and innovative technology to reduce the use of virgin materials in its products. It has been developed to help the construction industry achieve a lower carbon footprint and improve its sustainability credentials. Recycore Technology uses as much recycled material as possible whilst ensuring that products have at least the same proven performance characteristics as the virgin products that they replace. Recycore Technology products are tested to industry standards and, where applicable, will be third-party approved, e.g. Kitemarked. Therefore, Recycore Technology acts as a quality assurance mark for both high quality and sustainable products. Wavin has applied Recycore Technology to its new multi-layer, solid-core pipes, made with over 50% recycled content.

Why Recycore Technology?


There is growing demand from the construction industry for greener products that can be more easily recycled or that are made from recycled materials; or, better still, a combination of the two. WRAP , DEFRA and the Environment Agency are all on record saying that they would like to see greater levels of plastics recycling in the UK. It is not just government and legislative demand that is pushing change either. Wavins research has revealed widespread market demand for construction products that are more environmentally friendly. Recycore Technology is Wavins way of helping customers to meet tough new regulations and their own sustainability commitments.

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Introducing new Recycore Soil Pipe

Where has Recycore Technology been applied?


110 and 160mm soil pipes Multi-layer construction Over 50% recycled material in solid core BS EN 13476 Kitemarked

Independently tested and proven to have the same performance characteristics as BS EN 1329 but this standard precludes the use of multi-layer construction Available from Osma in black, grey and white

Product features

Same dimensional accuracy as current pipes dentical strength and impact I resistance as current pipes  ame performance under S thermal expansion or contraction as current pipes

 dentical resistance I to chemicals as current pipes Same ease of installation as current pipes  ade with at least M 50% recycled material A life in excess of 50 years

Email: info@wavin.co.uk

www.osma.co.uk

Soil Systems Overview

Ring Seal

PVC-U Ring-Seal Soil System: OsmaSoil


l

Simple-to-use system: saves time and site costs Quick, efficient assembly by means of push-fit jointing and some solvent joints Available in 82, 110 and 160mm diameters Colour choice: Black, Grey and White (dependent on size/component) 82/110/160 mm fittings and 82mm pipe in PVC-U to BS EN 1329-1:2000 110/160mm pipe manufactured in PVC-U to BS EN 1453-1:2000 110 / 160mm pipes made with Wavin's Recycore Technology (see pages 4-5).

Introduction to Soil Systems


The OSMA range offers a choice of two soil systems to meet performance and installation requirements for all types of building, from single dwellings to large residential, commercial or industrial premises. In addition, OSMA WC Connectors provide efficient and reliable connection for all WC layouts.

Table 1: PVC-U Ring-Seal Soil system: Pipe Dimensions (mm) and Weights (kg/m) Nominal Size 82 110 160 Outside Diameter Min Max 82.4 110.0 160.0 82.8 110.3 160.4 Wall Thickness Min Max 3.3 3.2 3.2 3.5 3.5 3.8 Average Weight (kg/m) 1.22 1.64 2.44

Table 2: PVC-U Ring-Seal Soil system: Socket Dimensions (mm) Nominal Size 82 110 160 Internal Depth Ring-seal Solvent-weld 55 65 80 45 50 58 Maximum Outside Diameter Ring-seal Solvent-weld 113 132 192 89 118 168

All 110mm and 160mm plain ended and single socketed soil pipe in this range is now manufactured using Wavin's Recycore Technology and contains at least 50% recycled PVC

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Soil Systems Overview

Solvent Weld

WC Connectors

PVC-U Solvent Weld Soil System: OsmaSoil


l l l

A secure method of jointing 110 and 160mm pipes and fittings Colour choice: Black, Grey and White (dependent on size/component) Fittings manufactured in PVC-U to BS EN 1329-1:2000 110/160mm pipe manufactured in PVC-U to BS EN 1453-1:2000 110 / 160mm pipes made with Wavin's Recycore Technology (see pages 4-5).

Table 3: PVC-U Solvent Weld Soil system: Pipe Dimensions (mm) and Weights (kg/m) Nominal Size 110 160 Outside Diameter Min Max 110.0 160.0 110.3 160.4 Wall Thickness Min Max 3.2 3.2 3.5 3.8 Average Weight (kg/m) 1.64 2.44

Table 4: PVC-U Solvent Weld Soil system: Socket Dimensions (mm) Nominal Size 110 160 Internal Depth
Without Expansion Cap With Expansion Cap

Maximum Outside Diameter


Without Expansion Cap With Expansion Cap

48 58

65 86

121 172

126 177

PVC-U WC Connectors: OsmaSoil


Connectors for all WC configurations, including OSMA WC Manifold Branches, designed to connect up to 8 WCs onto 1 float.

Email: info@wavin.co.uk

www.osma.co.uk

Waste Systems Overview

ABS Solvent Weld

ABS Solvent Weld Waste System: OsmaWeld


l l l

32, 40 and 50mm pipes and fittings Colour choice: Black, Grey and White Manufactured in ABS (Acrilonytrile Butadiene Styrene) to BS EN 1455-1: 2000

Introduction to Waste and Overflow Systems


The OSMA range offers a choice of three waste systems: push-fit waste and two solvent weld waste systems for standard and high temperature usage. Supported by V-Joint traps, two overflow systems (push-fit and solvent weld options) and condensate drainage. The systems fully coordinate with OSMA Soil systems

Table 5: ABS Solvent Weld Waste system: Pipe Dimensions (mm) and Weights (kg/m) Nominal Size 32 40 50 Outside Diameter Min Max 36.1 42.7 55.7 36.5 43.1 56.1 Wall Thickness Min Max 1.8 1.9 2.0 2.2 2.3 2.4 Average Weight (kg/m) 0.23 0.28 0.40

Table 6: ABS Solvent Weld Waste system: Socket Dimensions (mm) Nominal Size 32 40 50 Internal Depth 20 24 32 Maximum Outside Diameter 41 47 60

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Waste Systems Overview

PVC-C Solvent Weld

PVC-C Solvent Weld Waste System


l l l l

32, 40 and 50mm pipes and fittings Colour choice: Black and White Fire retardant properties Designed to withstand higher temperatures. The chlorinated PVC material has heat resistant properties. UV resistant: suitable for exterior as well as interior installation Manufactured in PVC-C Chlorinated poly (vinyl chloride)) to BS EN 1566-1: 2000

Table 7: PVC-C Solvent Weld Waste system: Pipe Dimensions (mm) and Weights (kg/m) Nominal Size 32 40 50 DN/OD 36 43 55 Outside Diameter Min Max 36.1 42.7 55.7 36.5 43.1 56.1 Wall Thickness Min Max 1.8 1.9 2.0 2.2 2.3 2.4 Average Weight (kg/m) 0.29 0.36 0.50

Table 8: PVC-C Solvent Weld Waste system: Socket Dimensions (mm) Nominal Size 32 40 50 DN/OD 36 43 55 Internal Depth (minimum) 21 23 28 Maximum Outside Diameter 41 48 61

Email: info@wavin.co.uk

www.osma.co.uk

Waste Systems Overview

PP Push-Fit Waste

PP Push-Fit Waste System


l

Simple-to-use system: saves time and site costs Quick, efficient assembly by means of push-fit jointing 32, 40 and 50mm pipes and fittings Colour choice: Black, Grey and White (32 and 40mm versions) 50mm: Grey and White Manufactured in Polypropylene to BS EN 1451-1:2000

l l

Table 9: PP Push-Fit Waste system: Pipe Dimensions (mm) and Weights (kg/m) Nominal Size 32 40 50 DN/OD* 34 41 54 Outside Diameter Min Max 34.4 40.8 53.9 34.8 41.2 54.3 Wall Thickness Min Max 1.8 1.9 2.0 2.2 2.3 2.4 Average Weight (kg/m) 0.187 0.225 0.335

Table 10: PP Push-Fit Waste system: Socket Dimensions (mm) Nominal Size 32 40 50 DN/OD* 34 41 54 Internal Depth 33 34 36 Maximum Outside Diameter 49 55 70

*DN/OD as stated in BS EN 1451-1 Standard

10

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Waste Systems Overview

V-Joint Traps

Condensate

V-Joint Traps
l

32, 40 and 50mm diameter domestic traps and accessories For use with all OSMA waste systems and with copper pipe Comprehensive range including tubular, bottle, bath and washing machine traps, and shower gullies Colour: White only Manufactured in Polyethylene to BS 3943:1983 BS EN 1451-1:2000 plastic pipe should be first warmed in hot water before connection is made to the trap

l l

Table 11: V-Joint Traps: Socket Dimensions (mm) Nominal Size 32 40 50 Internal Depth 39 40 49 Maximum Outside Diameter 60 66 68

Condensate Drainage
l

For installation in association with new and replacement condensing boilers for domestic central heating For direct connection to OSMA Drainage Systems via soil stack, rainwater downpipe or external soakaway Including traps, connectors, external soakaway and non-return valve. Compatible with all OSMA Overflow Systems Easy installation of all components Supports new energy efficiency regulations under Part L

l l

Email: info@wavin.co.uk

www.osma.co.uk

11

Waste Systems Overview

Overflow

Solvent Weld Overflow System


l l l

21.5 Solvent Weld System Colour choice: White only Removing overflow water from condensing boilers and cisterns/tanks Compatible with OSMA Condensate Fittings Allows direct connection to condensing boilers fittings Secure permanent jointing Manufactured in ABS (fittings) and PVC-U (pipe)

l l

Table 12: ABS & PVC-U Solvent Weld Overflow System: Pipe Dimensions (mm) and Weights (kg/m) Nominal Size 21.5 Outside Diameter Min Max 21.5 21.63 Wall Thickness Min Max 1.09 1.27 Average Weight (kg/m) 0.145

Table 13: ABS & PVC-U Solvent Weld Overflow System: Socket Dimensions (mm) Nominal Size 21.5 Internal Depth 26 Maximum Outside Diameter 27

PP Push-fit Overflow System


l l l

21.5mm push-fit system Colour: White only Manufactured in Polypropylene

Table 14: PP Push-Fit Overflow System: Pipe Dimensions (mm) and Weights (kg/m) Nominal Size 21.5 Outside Diameter Min Max 21.5 21.63 Wall Thickness Min Max 1.09 1.27 Average Weight (kg/m) 0.075

Table 15: Solvent Weld Overflow System: Pipe Dimensions (mm) Nominal Size 21.5 Internal Depth 26 Maximum Outside Diameter 26

12

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Estimating Data

Jointing Material Allowances

Estimating Data
The following data is provided to help estimation of quantities required for pipe support and jointing.
Table 16: Maximum Pipe Support Centres Pipe Size (mm) 19 32 40 50 82 110 160 Centres (m) Vertical Horizontal 0.5 1.2 1.2 1.2 2 2 2 0.5 0.5 0.5 0.6 1 1 1.2

Pipe Support
Pipes should be supported at the following maximum centres.

Offset Bends
Pipe Brackets should also be fitted around the Offset Bend or directly below.

Jointing Material Allowances Lubricant Allowance


For push-fit ring-seal joints (approximate figures)
Table 17: Lubricant Usage Guide Description Silicone Lubricant 50g tube Part No. 4S391 32 44 Nominal Pipe Sizes (mm) No. of Joints 40 50 82 110 37 20 16 9 160 4

Degreasing Cleaner/Solvent Cement Allowances


For solvent weld joints (approximate figures)
Table 18: Cleaner/Solvent Cement Usage Guide Description Degreasing Cleaner No.1 125ml can Degreasing Cleaner No.1 250ml can Solvent Cement No.2 125ml can Solvent Cement No.2 250ml can Solvent Cement No.2 500ml can Part No. 4S379 4S380 4S383 4S384 4S385 Nominal Pipe Sizes (mm) No. of Joints 19 32 40 50 82 110 120 70 45 33 25 16 240 90 180 360 140 45 90 180 90 30 60 120 66 20 40 80 50 8 16 32 32 5 11 22 160 10 20 3 6 12

Email: info@wavin.co.uk

www.osma.co.uk

13

Soil & Waste System Selector

Soil & Waste Profiles - Key Fittings

Pipe or Socket

Solvent Weld -

PVC-U Ring-Seal Soil PVC-U Solvent Weld Soil ABS Solvent Weld Waste PVC-C Solvent Weld Waste PP Push-Fit Waste

BG W BG W BG W BW BG W

OSMA Soil Systems

OSMA Waste Systems

OSMA Overflow Systems

PVC-U Solvent Weld PP Push-Fit

W W

Other Fittings OsmaLink Soil Manifold 4S495 and 6-Boss Soil Manifold 4S597
For use with waste pipes

WC Connectors
For use with Push-Fit and Solvent Weld Soil systems: Connectors (for BS 5503 WCs) 21/2 14 90 90 (Access) Connectors (for BS 1213 WCs) Straight 871/2 Easy-Fit Pan Connectors (for BS 1213 WCs) Straight Offset 14 90

Vents
Air Admittance Valves (110mm and 40mm) Terminal Fittings Pipe Flashings (pitched and flat roof) Roof Outlets

Manifold Branches
(for connection of up to 8 WCs) Straight 8 151/2 23 301/2 38

Traps
For use with all OSMA Waste systems. Trap types: Bottle Tubular Bath Shower Washing Machine

Fire Stop Seals


For 50, 82, 110 and 160mm pipework

14

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Push-Fit/SW -

Suspended

Brackets

Push-Fit

Sockets

110 mm

160 mm

Socket

19 mm

32 mm

40 mm

50 mm

82 mm

Colour

Pipe

Pipe

Clip

Soil & Waste System Selector

Adjust.

Single

Double

abc ab

tuvw uvw

def ghj def ghj ghj

mnp qrs mnp qrs mnp

dx x

*Key Connectors
a Connector to Cast-Iron Socket b Connector to Cast-Iron Spigot c Connector to Cast-Iron or Clay Drain Socket d Straight Tank Connector e Universal Connector f Male Iron Connector g Female Iron Connector h Connector to BS 659 Copper Spigot Compression Joint j Connector to BS 659 Copper Compression Fitting k Universal Compression Connector

Colour Key Reducers


m Reducer 40 to 32mm n Reducer 50 to 32mm p Reducer 50 to 40mm q Reducer to 19mm Overflow r Reducer to 35mm copper pipe s Reducer to 42mm copper pipe t Reducer 82 to 50mm u Reducer 110 to 50mm v Reducer 110 to 82mm w Reducer 160 to 110mm x Bent Tank Connector *NOTE: Guide only. Some connectors not available in more than one size. Some waste connectors and reducers listed are available in two versions. Check listings to ensure availability of suitable fitting
Colour Black Grey White Ref. Code B G W

Email: info@wavin.co.uk

www.osma.co.uk

Bossed Pipe -

Equal/Cross

Connectors

(See KEY)*

(See KEY)*

Equal/Tee

Reducers

Branches

Unequal

Unequal

Access

Branch

Corner

Bends

Offset

Bend

87

67

11

Pipe

90

76

45

30

15

90

30

45

15

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Abbreviations
P/E S/S D/S S/SW SW/S D/SW Pipe with both ends plain or fittings with one plain end and one special end. Pipe and fittings with one or more push-fit (ring-seal) sockets, but always one plain or special end. Fittings with push-fit (ring-seal) sockets at all ends. Fittings with one or more push-fit (ring-seal) sockets but always one solvent socket. Fittings with one or more solvent sockets and one plain or special end Fittings with solvent sockets at all ends

Pipe Socketed Pipe


l l l l

One plain end, one ring-seal socket 110 /160mm sizes are made with Wavin Recycore technology a multi-layer construction with over 50% recycled material in solid core 110 /160 mm pipe sizes are BS EN 1453-1:2000 kitemarked but have exactly the same performance characteristics as BS EN 1329-1:2000 82mm pipe is standard PVC-U pipe, kitemarked to BS EN 1329-1

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number Length (m) A (mm) (O/D) B (mm) 82 3S042 a 2 51 104 82 3S043 a 3 51 104 82 3S044 a 4 51 104 110 4S042 a 2 65 132 110 4S050 a 2.5 65 132 110 4S043 a 3 65 132 110 4S044 a 4 65 132 160 6S043 a 3 88 191 160 6S044 a 4 88 191 Colours: All products available in Grey 3S043, 3S044 and 4S042 available in Black, Grey 4S043 and 4S044 available in Black, Grey, White

Plain-Ended Pipe
l l l

110 /160mm sizes are made with Wavin Recycore technology a multi-layer construction with over 50% recycled material in solid core 110 /160 mm pipe sizes are BS EN 1453-1:2000 kitemarked but have exactly the same performance characteristics as BS EN 1329-1:2000

82mm pipe is standard PVC-U pipe, kitemarked to BS EN 1329-1

Material: PVC-U

Nominal Part Dimensions Size (mm) Number Length (m) 4 82 3S074 a 3 110 4S073 a 4 110 4S074 a 4 160 6S074 a Colours: All products available in Black, Grey 4S073 and 4S074 available in Black, Grey, White

16

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Brackets Pipe Bracket


l

For support centres, see pages 87 and 106

Material: PVC-U

Nominal Size (mm)

Part Number

A (mm)

Dimensions B (mm) C (mm)

D (mm) 16 25 32

Fixing Hole 6.5 Dia 6.5 Dia 8 Dia

82 3S082 a 76 92 112 110 4S082 a 94 120 140 160 6S082 a 123 175 200 Colours: All products available in Black, Grey 4S082 available in Black, Grey, White

Socket Bracket
l l

Position in the recessed area adjacent to the sealing-ring housing For support centres, see pages 87 and 106

Material: PVC-U

Nominal Size (mm)

Part Number

A (mm)

Dimensions B (mm) C (mm)

D (mm) 28.5 25

Fixing Hole 6.5 Dia 6.5 Dia

82 3S083 a 76 78 140 110 4S083 a 94 120 140 Colours: All products available in Black, Grey 4S083 available in Black, Grey, White

Pipe or Socket Bracket


l l

Multi-functional support component that can be used for pipes or sockets When using as a socket bracket, always position unit in the recessed area adjacent to the sealing-ring housing For support centres, see pages 87 and 106

Material: BZP-coated steel

Nominal Size (mm) 82 110 160

Part Number 3S084 a 4S084 a 6S084 a

A (mm) 78 94 124

Dimensions B (mm) C (mm) 120 160 220 140 180 240

D (mm) 16 20 25

Fixing Hole 7 Dia 7 Dia 7 Dia

Email: info@wavin.co.uk

www.osma.co.uk

17

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Suspended Brackets Adjustable Pipe Bracket Assembly


l l

Pack contains Threaded Rod, Threaded Bracket, Bracket Plate, and Pipe/socket Bracket For support centres, see pages 87 and 106 Nominal Size (mm) 110 160 Part Number 4S086 6S086

Material: BZP-coated mild steel

Adjustable Socket Bracket and Brace Assembly


l l

Pack contains Threaded Rod, Threaded Bracket, Bracket Plate, two Adjustable Braces, and Pipe/Socket Bracket For support centres, see pages 87 and 106

Threaded Rod

Material: BZP-coated mild steel

Nominal Size (mm) 110 160


Threaded Bracket

Part Number 4S085 6S085

COMPONENTS: M8 Threaded Rod


Material: BZP-coated mild steel

Nominal Size (mm) -

Part Number -

Dimensions A (mm) Diameter 500 8

Threaded Bracket
Material: BZP-coated mild steel Bracket Plate

Nominal Size (mm) -

Part Number -

A (mm) 120

Dimensions B (mm) 40

C (mm) 30

Bracket Plate
Material: BZP-coated mild steel

Nominal Size (mm) -

Part Number -

A (mm) 240

Dimensions B (mm) C (mm) 110 20

D (mm) 80

Adjustable Brace
l

Used for creating anchor points

Material: BZP-coated mild steel Adjustable Brace

Nominal Size (mm) -

Part Number -

A Min (mm) 264

Dimensions A Max (mm) 493

B (mm) 260

Pipe or Socket Bracket


Material: BZP-coated mild steel

Nominal Size (mm) 110 160

Part Number -

A (mm) 94 124

Dimensions B (mm) C (mm) 160 220 180 240

D (mm) 20 25

Fixing Hole 7 Dia 7 Dia

Pipe/Socket Bracket

18

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Sockets S/SW Single Socket


l l

One solvent weld socket and one push-fit ring-seal socket Used for creating a fixed ring-seal joint on a plain-ended pipe or fitting, or where an expansion joint is required to accommodate thermal movement

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 97 2 82 3S124 a 105 2 110 4S124 a 135 2 160 6S124 a Colours: All products available in Black, Grey 4S124 available in Black, Grey, White

D/S Double Socket


l l

Push-fit ring-seal socket at each end Used as a slip coupler for making repairs

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 82 3S105 a 110 4S105 a 160 6S105 a Colours: All products available in Grey 3S105 and 4S105 available in Black, Grey

Dimensions A (mm) 102 111 145

D/SW Double Socket


l

Solvent weld socket at each end

Material: PVC-U

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 110 4S104 98 2 160 6S104 119 3 Colours: All products available in Black 4S104 available in Black, Grey, White

Connectors S/S Connector to Cast-Iron Soil Socket


l

Connector to BS 416 cast-iron soil socket Part Number 4S106 a Dimensions A (mm) B (mm) 162 123

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

S/S Connector to Cast-Iron or Clay Drain Socket


l

Connector to BS 1211 or BS 437 cast-iron socket or BS 65 clay drain socket

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S107 a

A (mm) 121

Dimensions B (mm) 51

C (mm) 134

Email: info@wavin.co.uk

www.osma.co.uk

19

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Connectors continued P/E Connector to Cast-Iron Spigot


l l l l

Heat-shrink connector to BS 416 cast-iron spigot Use 2 x 3S130 Seals with 82mm connector Use 1 x 4S119 with 110mm connector Use 2 x 6S130 Seals with 160mm connector

Material: PVC-U

Nominal Size (mm) 82 110 160 Colour: Grey

Part Number 3S134 4S134 6S134 A (mm) 325 300 330

Dimensions Cast-Iron Spigot (O/D) B Min (mm) B Max (mm) 80 105 108 125 158 185

Gasket
l

For use with Connector 4S134 (above) Part Number 4S119

Material: Neoprene synthetic rubber

Nominal Size (mm) 110 Colour: Black

Connector to Cast-Iron Socket


l

Connector to BS 416 cast-iron soil socket

Material: Neoprene synthetic rubber

Nominal Size (mm) 110 Colour: Black

Part Number 4S206

Dimensions A (mm) 66

Internal Drain Connector


l
A

For 32mm/40mm waste pipe and 50mm waste pipe Part Number 4D298 4D299 Dimensions A (mm) 60.5 60.5

Material: Neoprene synthetic rubber

Nominal Size (mm) 110x32/40 110x50 Colour: Black

Reducers S/S Reducer


Material: PVC-U, with Rubber seals

Nominal Size (mm) 82x50 Colours: Black, Grey

Part Number 3S094 a

Dimensions A (mm) B (mm) 119 68

20

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Reducers continued S/S Reducer


Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 103 53 110x50 4S096 a 103 53 110x82 4S095 a 130 68 160x110 6S099 a Colours: All products available in Grey 4S096 and 4S095 available in Black, Grey

Bends S/S Bend 871/2


l

One plain end and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 128 125 82 3S161 a 162 160 110 4S161 a 240 247 160 6S161 a Colours: All products available in Grey 3S161 available in Black, Grey 4S161 available in Black, Grey, White

S/SW Bend 871/2


l

One solvent weld socket and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S361 a

Dimensions A (mm) B (mm) 160 160

S/S Bend 76
l

One plain end and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S164 a

A (mm) 146

Dimensions B (mm) 148

C (mm) 180

S/S Bend 671/2


l

One plain end and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Size (mm) 82 110 160 Colour: Grey

Part Number 3S162 a 4S162 a 6S162 a

A (mm) 132 155 177

Dimensions B (mm) 121 154 168

C (mm) 180 212 240

Email: info@wavin.co.uk

www.osma.co.uk

21

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Bends continued S/S Bend 45


l

One plain end and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 81 70 82 3S163 a 83 87 110 4S163 a 140 118 160 6S163 a Colours: All products available in Grey 3S163 available in Black, Grey 4S163 available in Black, Grey, White

C (mm) 126 145 215

S/SW Bend 45
l

One solvent weld socket and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S363 a

A (mm) 98

Dimensions B (mm) 86

C (mm) 155

S/S Bend 30
l

One plain end and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S166 a

A (mm) 92

Dimensions B (mm) 95

C (mm) 162

S/S Bend 15
l

One plain end and one push-fit ring-seal socket

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S167 a

A (mm) 85

Dimensions B (mm) 76

C (mm) 157

Adjustable Bends Adjustable Bend 90


l l l l l

One plain end and one push-fit ring-seal socket Variable angle up to 90 Can accommodate up to 60mm centre-line to centre-line misalignment of pipework Rotate segments to achieve required change of direction (flow arrow on socket indicates orientation of fitting) BBA certificated (Certificate No. 89/2174)

Material: Polypropylene, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S179

Dimensions A (mm) B (mm) 167 165

22

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Adjustable Bends continued Adjustable Bend 30


l l l l

One plain end and one push-fit ring-seal socket Variable angle up to 30 Rotate segments to achieve required change of direction (flow arrow on socket indicates orientation of fitting) BBA certificated (Certificate No. 89/2174) Part Number 4S173 Dimensions B (mm) 90

Material: Polypropylene, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

A (mm) 97

C (mm) 180

Offset Bends SW/S Offset Bend 671/2


l l

One plain end and one solvent weld socket Minimum achievable offsets: 82 115mm, 110 137mm, 160 233mm

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 82 3S435 a 92 87 99 105 110 4S435 a 170 169 160 6S435 a Colours: All products available in Grey 4S435 available in Black, Grey, White

C (mm) 123 143 230

S/SW Offset Bend 671/2


l l

One solvent weld socket and one push-fit ring-seal socket Minimum achievable offsets: 82 115mm, 110 137mm, 160 233mm

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 82 3S440 a 95 87 110 99 110 4S440 a 177 160 160 6S440 a Colours: All products available in Grey 3S440 available in Black, Grey 4S440 available in Black, Grey, White

C (mm) 123 140 225

S/S Offset Bend 671/2


l l

One plain end and one push-fit ring-seal socket Minimum achievable offsets: 82 115mm, 110

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 82 3S444 a 95 87 110 105 110 4S444 a Colours: All products available in Black, Grey 4S444 available in Black, Grey, White

C (mm) 123 147

Email: info@wavin.co.uk

www.osma.co.uk

23

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Offset Bends continued D/S Offset Bend 671/2


l l

Fitted with two push-fit ring-seal sockets Minimum achievable offset: 137mm Dimensions B (mm) 110

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S445 a Colours: Black, Grey, White

A (mm) 110

C (mm) 155

Soil Manifold System OsmaLink Soil Manifold


l l l l l

One plain end and one push-fit ring-seal socket Permits up to three 50mm connections to be made at floor level Complies with BS EN 12056-2:2000 clause ND. 3.3.2 Make connections using 2S354 (below), 2S355 or 2S356 Minimum installation aperture: 240mm square Part Number 4S595 a Dimensions B (mm) C (mm) 55 160

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

A (mm) 138

D (mm) 275

All-Fit Reducer 40:32mm


l l

Connects to 32mm plastic pipe to BS EN 1451-1/BS EN 1455-1/ BS EN 1566-1, or to copper pipe manufactured to BS 659 or BS 2871 Use with 2S355 (below) when a bend is required Part Number 2S354 a Dimensions A (mm) 54

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

All-Fit Reduction Bend 50:40mm


l

Connects to 40mm plastic pipe to BS EN 1451-1/BS EN 1455-1/ BS EN 1566-1, or to copper pipe manufactured to BS 659 or BS 2871 Part Number 2S355 a Dimensions A (mm) B (mm) 70 65

Material: Polypropylene

Nominal Size (mm) 50 Colour: White

All-Fit 90 Spigot Bend 50:40mm


l

Connects to 50mm plastic pipe to BS EN 1451-1/BS EN 1455-1/ BS EN 1566-1, or to copper pipe manufactured to BS 659 or BS 2871

Material: ABS

Nominal Size (mm) 50 Colour: White

Part Number 2S356 a

Dimensions A (mm) B (mm) 79 64

24

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Manifold 6 Boss Manifold


A C

l l l

l l l

One plain end and one solvent weld socket 6 boss connection points (No boss adaptors required) Dual 40/50mm solvent weld connection Compact design, 163mm body sits easily into 200mm drilled or formed hole Branch low in fitting: 132mm from centreline of branch horizontal inlet to 50mm spigot invert Horizontal waste connection: instead of vertical connection no upstanding bends required

E F

Material: PVC-U

Nominal Size (mm)

Part Number

110 4S597 Colour: Grey

A (mm) 204

B (mm) 222

Dimensions C D (mm) (mm) 94 163

E (mm) 79

F (mm) 184

Single Branches S/S Single Branch 871/2


l l

One plain end and two push-fit ring-seal sockets With closed boss socket positions: two on 82mm and 160mm fittings, three on 110mm fitting

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 82 3S190 a 155 118 150 120 110 4S190 a 230 170 160 6S190 a Colours: All products available in Grey 3S190 available in Black, Grey 4S190 available in Black, Grey, White

C (mm) 146 142 230

S/S Single 5-Boss Branch 871/2


l l

One plain end and two push-fit ring-seal sockets Five closed boss sockets, of which two are positioned 84mm below the centre-line of the branch entry. These can be used for low-level waste connections (as alternative to Soil Manifold 4S595) Part Number Dimensions B (mm) C (mm) 118 84

Material: PVC-U, with Rubber seals

Nominal Size (mm)

A (mm) 150

D (mm) 101

110 4S195 a Colours: Black, Grey, White

S/SW Single 5-Boss Branch 871/2


l l

One solvent weld socket and two push-fit ring-seal sockets Five closed boss sockets, of which two are positioned 84mm below the centre-line of the branch entry. These can be used for low-level waste connections (as alternative to Soil Manifold 4S595) Part Number 4S395 a Dimensions B (mm) C (mm) 118 84

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

A (mm) 150

D (mm) 98

Email: info@wavin.co.uk

www.osma.co.uk

25

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Single Branches continued S/S Unequal Single Branch 871/2


l l

One 160mm plain end/push-fit ring-seal socket, and one 110mm push-fit ring-seal socket on the branch Two closed boss socket positions

Material: PVC-U, with Rubber seals

Nominal Size (mm) 160 Colour: Grey

Part Number 6S198 a

A (mm) 176

Dimensions B (mm) 148

C (mm) 155

S/S Single Branch 76


l l

One plain end and two push-fit ring-seal sockets Three closed boss socket positions

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S220 a Colours: Black, Grey

A (mm) 161

Dimensions B (mm) 159

C (mm) 155

S/S Single Branch 671/2


l l l

One plain end and two push-fit ring-seal sockets 110mm fitting has two closed boss socket positions. 82mm fitting does not have side bosses

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number A (mm) 82 3S200 a 151 150 110 4S200 a Colours: All products available in Grey 4S200 available in Black, Grey

Dimensions B (mm) 121 159

C (mm) 116 155

S/S Single Branch 45


l

One plain end and two push-fit ring-seal sockets

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S210 a Colours: Black, Grey

A (mm) 135

Dimensions B (mm) 190

C (mm) 85

26

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Double Branches S/S Double Branch 871/2


l l l

One plain end and three push-fit ring-seal sockets Two closed boss socket positions Do NOT use for connecting back-to-back WCs in horizontal float installations: see relevant parts of BS EN 12056:2000

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S230 a Colours: Black, Grey

A (mm) 146

Dimensions B (mm) 115

C (mm) 149

S/S Unequal Double Branch 871/2


l l

One 160mm plain end/push-fit ring-seal socket, and two 110mm push-fit ring-seal sockets on the branch Two closed boss socket positions Part Number 6S238 a Dimensions B (mm) 138

Material: PVC-U, with Rubber seals

Nominal Size (mm) 160 Colour: Grey

A (mm) 176

C (mm) 164

S/S Double Branch 45


l

One plain end and three push-fit ring-seal sockets

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S250 a

A (mm) 147

Dimensions B (mm) 212

C (mm) 99

Corner Branch S/S Corner Branch 871/2


l l

One plain end and three push-fit ring-seal sockets One closed boss socket position

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S291 a

A (mm) 190

Dimensions B (mm) 125

C (mm) 144

Email: info@wavin.co.uk

www.osma.co.uk

27

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Bossed Pipes S/S Bossed Pipe


l l

One plain end and one push-fit ring-seal socket One open boss socket position

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 82 3S649 a Colours: Black, Grey

A (mm) 61

Dimensions B (mm) 90

C (mm) 86

S/S Bossed Pipe


l l

One plain end and one push-fit ring-seal socket Three closed boss socket positions and one open to receive appropriate Boss Socket Adaptor (page 30)

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 74 110 110 4S589 a 100 154 160 6S589 a Colours: All products available in Grey 4S589 available in Black, Grey, White

C (mm) 108 142

S/S Bossed Pipe


l

l l

Connects to 32mm [11/4"] or 40mm [11/2"] plastic pipe to BS EN 1451-1/BS EN 1455-1/BS EN 1566-1, or to copper pipe manufactured to BS 659 or BS 2871 One plain end and one push-fit ring-seal socket Three closed boss socket positions and one open, fitted with Adaptor 2S398 or 2S399 (page 30) Part Number 4S581 a 4S582 a Dimensions B (mm) 114 114

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110x32 110x40 Colour: Grey

A (mm) 106 110

C (mm) 100 100

D/SW Ring-Seal Bossed Pipe


l

l l

Connects to 32mm [11/4"] or 40mm [11/2"] plastic pipe to BS EN 1451-1/BS EN 1455-1/BS EN 1566-1, or to copper pipe manufactured to BS 659 or BS 2871 Two solvent weld sockets One push-fit socket position

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110x32 4S583 a 110x40 4S584 a Colours: Black, Grey, White

Dimensions A (mm) B (mm) 96 150 96 150

28

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Bossed Pipes continued S/SW Bossed Pipe


l l

One plain end and one push-fit ring-seal socket Three closed boss socket positions and one open to receive appropriate Boss Socket Adaptor (page 30) Dimensions B (mm) 111

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S590 a Colours: Black, Grey

A (mm) 74

C (mm) 98

D/SW Short Bossed Pipe


l
BA

Three closed boss socket positions for use with the appropriate Boss Socket Adaptor (page 30) Three closed 40mm [11/2"] spigot tail positions also allow for direct connection of 40mm [11/2"] solvent weld sockets

Material: PVC-U

Nominal Size (mm)

Part Number

A (mm) 56

Dimensions B (mm) C (mm) 43 124

D (mm) 74

110 4S588 a Colours: Black, Grey

Strap Bosses Strap Boss


l

For making side connections on BS EN 1329 plastic pipe after construction

Material: PVC-U

Nominal Part Size (mm) Number 82 3S319 a 110 4S319 a Colours: All products available in Black, Grey 4S319 available in Black, Grey, White

Dimensions A (mm) 63 77

Back-to-Back Strap Boss


l

For making side connections on BS EN 1329 plastic pipe after construction

Material: PVC-U

Nominal Size (mm) 110 Colour: Grey

Part Number 4S318 a

Dimensions A (mm) 80

Email: info@wavin.co.uk

www.osma.co.uk

29

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Boss Socket Adaptors S/S Ring-Seal Boss Adaptor


l l

Suitable for all OsmaSoil fittings with boss socket positions Connects to 32mm [11/4"], 40mm [11/2"] or 50mm [2"] plastic pipe to BS EN 1451-1/BS EN 1455-1/BS EN 1566-1, or to copper pipe manufactured to BS 659 or BS 2871 Horizontal adaptors have an inbuilt 21/2 fall Dimensions A (mm) B (mm) 50 27 53 30

Material: PVC-U

Nominal Part Size (mm) Number 32 2S398 40 2S399 Colours: Black, Grey, White

S/S Ring-Seal Boss Adaptor


l l

Suitable for all OsmaSoil fittings with boss socket positions Connects to 32mm [11/4"], 40mm [11/2"] or 50mm [2"] plastic pipe to BS EN 1451-1/BS EN 1455-1/BS EN 1566-1, or to copper pipe manufactured to BS 659 or BS 2871 Horizontal adaptors have an inbuilt 21/2 fall Dimensions A (mm) B (mm) 70 52

Material: PVC-U

Nominal Part Size (mm) Number 50 2S402 Colours: Black, Grey, White

S/S Ring-Seal Boss Adaptor - 90


l l

Suitable for all OsmaSoil fittings with boss socket positions Connects to 50mm [2"] plastic pipe to BS EN 1455-1/BS EN 1566-1 or use with Long Tail Bend 2Z359 Part Number 2S360 Dimensions A (mm) B (mm) 50 31

Material: ABS

Nominal Size (mm) 50 Colour: Grey

Access Fittings S/S Access Pipe


l l

One plain end and one push-fit ring-seal socket Fitted with bolted, oval access door Part Number 3S274 a Dimensions A (mm) 255

Material: PVC-U, with Rubber seals

Nominal Size (mm) 82 Colours: Black, Grey

30

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Access Fittings continued S/S Bossed Access Pipe


l l l l

One plain end and one push-fit ring-seal socket Three closed socket boss positions Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 95 118 110 4S274 a 130 155 160 6S274 a Colours: All products available in Grey 4S274 available in Black, Grey, White

C (mm) 118 150

S/SW Bossed Access Pipe


l l l l

One solvent weld socket and one push-fit ring-seal socket Three closed socket boss positions Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S374 a

A (mm) 95

Dimensions B (mm) 118

C (mm) 114

S/S Access Bend 871/2


l l l

One plain end and one push-fit ring-seal socket Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S169 a Colours: Black, Grey

A (mm) 163

Dimensions B (mm) 80

C (mm) 170

S/SW Access Bend 871/2


l l l

One solvent weld socket and one push-fit ring-seal socket Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 Colour: Grey

Part Number 4S369 a

A (mm) 163

Dimensions B (mm) 80

C (mm) 160

Email: info@wavin.co.uk

www.osma.co.uk

31

Product Selector

PVC-U Ring-Seal Soil: OsmaSoil

Access Fittings continued S/S Access Branch 871/2


l l l l

One plain end and two push-fit ring-seal sockets Two closed socket boss positions Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83) Dimensions B (mm) 120

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S502 a Colours: Black, Grey

A (mm) 150

C (mm) 142

Access Saddle
l l l

For providing access to BS EN 1329/BS EN 1453 plastic pipe after construction, or where an access pipe or branch is not suitable Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S275 a Colours: Black, Grey

A (mm) 103

Dimensions B (mm) 35

C (mm) 35

Plugs P/E Access Plug


l

Fits into a ring-seal socket to provide an access point

Material: PVC-U

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 82 3S292 a 56 100 50 132 110 4S292 a 58 188 160 6S292 a Colours: All products available in Black, Grey 4S292 available in Black, Grey, White

P/E Socket Plug


l l

With one closed boss socket position Fits into a ring-seal socket to provide a connection point for a 32mm [11/4"], 40mm [11/2"] or 50mm [2"] waste pipe connection when fitted with the appropriate Boss Socket Adaptor (page 30)

Material: PVC-U

Nominal Size (mm) 110 Colours: Black, Grey

Part Number 4S296 a

Dimensions A (mm) B (mm) 54 132

32

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Pipe Plain-Ended Pipe


l l l

110 / 160mm sizes are made with Wavin Recycore technology a multi-layer construction with over 50% recycled material in solid core 110 /160 mm pipe sizes are BS EN 1453-1:2000 kitemarked but have exactly the same performance characteristics as BS EN 1329-1:2000 82mm pipe is standard PVC-U pipe, kitemarked to BS EN 1329-1

Material: PVC-U

Nominal Part Dimensions Size (mm) Number Length (m) 3 110 4S073 a 4 110 4S074 a 4 160 6S074 a Colours: All products available in Black, Grey 4S073 and 4S074 available in Black, Grey, White

Brackets Pipe Bracket


l

For support centres, see pages 87 and 106

Material: PVC-U

Nominal Size (mm)

Part Number

A (mm)

Dimensions B (mm) C (mm)

D (mm) 25 32

Fixing Hole 6.5 Dia 8 Dia

110 4S082 a 94 120 140 160 6S082 a 123 175 200 Colours: All products available in Black, Grey 4S082 available in Black, Grey, White

Socket Bracket
l l

Position in the recessed area adjacent to the sealing-ring housing For support centres, see pages 87 and 106

Material: PVC-U

Nominal Size (mm)

Part Number

A (mm)

Dimensions B (mm) C (mm)

D (mm) 25

Fixing Hole 6.5 Dia

110 4S083 a 94 120 140 Colours: All products available in Black, Grey 4S083 available in Black, Grey, White

Pipe or Socket Bracket


l l

Multi-functional support component that can be used for pipes or sockets When using as a socket bracket, always position unit in the recessed area adjacent to the sealing-ring housing For support centres, see pages 87 and 106

Material: BZP-coated steel

Nominal Size (mm) 110 160

Part Number 4S084 a 6S084 a

A (mm) 94 124

Dimensions B (mm) C (mm) 160 220 180 240

D (mm) 20 25

Fixing Hole 7 Dia 7 Dia

Email: info@wavin.co.uk

www.osma.co.uk

33

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Suspended Brackets Adjustable Pipe Bracket Assembly


l l

Pack contains Threaded Rod, Threaded Bracket, Bracket Plate, and Pipe/socket Bracket For support centres, see pages 87 and 106 Nominal Size (mm) 110 160 Part Number 4S086 6S086

Material: BZP-coated mild steel

Adjustable Socket Bracket and Brace Assembly


l l

Pack contains Threaded Rod, Threaded Bracket, Bracket Plate, two Adjustable Braces, and Pipe/Socket Bracket For support centres, see pages 87 and 106

Threaded Rod

Material: BZP-coated mild steel

Nominal Size (mm) 110 160


Threaded Bracket

Part Number 4S085 6S085

COMPONENTS: M8 Threaded Rod


Material: BZP-coated mild steel

Nominal Size (mm) -

Part Number -

Dimensions A (mm) Diameter 500 8

Threaded Bracket
Material: BZP-coated mild steel Bracket Plate

Nominal Size (mm) -

Part Number -

A (mm) 120

Dimensions B (mm) 40

C (mm) 30

Bracket Plate
Material: BZP-coated mild steel

Nominal Size (mm) -

Part Number -

A (mm) 240

Dimensions B (mm) C (mm) 110 20

D (mm) 80

Adjustable Brace
l

Used for creating anchor points

Material: BZP-coated mild steel Adjustable Brace

Nominal Size (mm) -

Part Number -

A Min (mm) 264

Dimensions A Max (mm) 493

B (mm) 260

Pipe or Socket Bracket


Material: BZP-coated mild steel

Nominal Size (mm) 110 160

Part Number -

A (mm) 94 124

Dimensions B (mm) C (mm) 160 220 180 240

D (mm) 20 25

Fixing Hole 7 Dia 7 Dia

Pipe/Socket Bracket

34

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Sockets S/SW Single Socket


l l

One solvent weld socket and one push-fit ring-seal socket Used for creating a fixed ring-seal joint on a plain-ended pipe or fitting, or where an expansion joint is required to accommodate thermal movement

Material: PVC-U, with Rubber seals

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 105 2 110 4S124 a 135 2 160 6S124 a Colours: All products available in Black, Grey 4S124 available in Black, Grey, White

D/S Double Socket


l l

Push-fit ring-seal socket at each end Used as a slip coupler for making repairs

Material: PVC-U, with Rubber seals

Nominal Part Size (mm) Number 110 4S105 a 160 6S105 a Colours: All products available in Grey 4S105 available in Black, Grey

Dimensions A (mm) 111 145

D/SW Double Socket


l

Solvent weld socket at each end

Material: PVC-U

Nominal Part Size (mm) Number 110 4S104 160 6S104 Colours: All products available in Black 4S104 available in Black, Grey

Dimensions A (mm) B (mm) 98 2 119 3

Connectors P/E Connector to Cast-Iron Spigot


l l l

Heat-shrink connector to BS 416 cast-iron spigot Use 1 x 4S119 with 110mm connector Use 2 x 6S130 Seals with 160mm connector Part Number 4S134 6S134 A (mm) 300 330 Dimensions Cast-Iron Spigot (O/D) B Min (mm) B Max (mm) 108 125 158 185

Material: PVC-U

Nominal Size (mm) 110 160 Colour: Grey

Gasket
l

For use with Connector 4S134 (above) Part Number 4S119

Material: Neoprene synthetic rubber

Nominal Size (mm) 110 Colour: Black

Email: info@wavin.co.uk

www.osma.co.uk

35

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Connectors continued Connector to Cast-Iron Socket


l

Connector to BS 416 cast-iron soil socket

Material: Neoprene synthetic rubber

Nominal Size (mm) 110 Colour: Black

Part Number 4S206

Dimensions A (mm) 66

Reducers SW/S Reducer


l l

Spigot connects to 110mm PVC-U solvent weld socket to BS EN 1329/BS EN 1453 Socket connects to 50mm ABS or PVC-C solvent weld pipe to BS EN 1455-1/BS EN 1566-1 Part Number 4S496 a Dimensions A (mm) B (mm) 89 50

Material: PVC-U

Nominal Size (mm) 110x50 Colour: Black

S/S Reducer
l l

Spigot connects to 110mm PVC-U solvent weld socket to BS EN 1329/BS EN 1453 Ring-seal socket connects to 82mm PVC-U pipe to BS EN 1329

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110x82 Colours: Black, Grey

Part Number 4S095 a

Dimensions A (mm) B (mm) 103 53

SW/S Reducer
l l

Spigot connects to 160mm PVC-U solvent weld socket to BS EN 1329/BS EN 1453 Solvent weld socket connects to 110mm PVC-U pipe to BS EN 1329/ BS EN 1453

Material: PVC-U, with Rubber seals

Nominal Size (mm) 160x110 Colour: Black

Part Number 6S499 a

Dimensions A (mm) B (mm) 117 65

Adaptor Expansion Cap


l l l

With integral ring-seal Converts OSMA Solvent Weld Soil sockets to push-fit expansion sockets See page 86 for advice on accommodating thermal movement

Material: PVC-U, with Rubber seals

Nominal Size (mm) 110 160 Colour: Black

Part Number 4S416 6S416

Dimensions A (mm) 22 27

36

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Bends D/SW Bend 871/2


l

Two solvent weld sockets

Material: PVC-U

Nominal Size (mm) 110 160 Colour: Black

Part Number 4S461 a 6S461 a

Dimensions A (mm) B (mm) 152 166 231 232

D/SW Bend 671/2


l

Two solvent weld sockets Part Number 4S462 a Dimensions B (mm) 138

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 141

C (mm) 192

D/SW Bend 45
l

Two solvent weld sockets Part Number 4S463 a 6S463 a Dimensions B (mm) 87 111

Material: PVC-U

Nominal Size (mm) 110 160 Colour: Black

A (mm) 87 128

C (mm) 148 204

SW/S Bend 45
l

One plain end and one solvent weld socket Part Number 4S263 a Dimensions B (mm) 105

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 87

C (mm) 167

SW/S Bend 111/4


l

One plain end and one solvent weld socket Part Number 4S268 a Dimensions B (mm) 88

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 75

C (mm) 162

SW/S Long-Tail Bend 871/2


l

One plain end and one solvent weld socket

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

Part Number 4S260 a

Dimensions A (mm) B (mm) 115 195

Email: info@wavin.co.uk

www.osma.co.uk

37

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Offset Bends SW/S Offset Bend


l l

One solvent weld socket and one push-fit ring-seal socket Minimum achievable offset: 137mm

Material: PVC-U

Nominal Part Size (mm) Number 110 4S435 a Colours: Black, Grey, White

A (mm) 99

Dimensions B (mm) 105

C (mm) 143

D/SW Offset Bend


l l

Two solvent weld sockets Minimum achievable offsets: 196mm

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

Part Number 4S450 a

A (mm) 108

Dimensions B (mm) 102

C (mm) 123

Manifold 6 Boss Manifold


A C

l l l l

l l

One plain end and one solvent weld socket 6 boss connection points (No boss adaptors required) Dual 40/50mm solvent weld connection Compact design, 163mm body sits easily into 200mm drilled or formed hole Branch low in fitting: 132mm from centreline of branch horizontal inlet to 50mm spigot invert Horizontal waste connection: instead of vertical connection no upstanding bends required Part Number Dimensions C D (mm) (mm) 94 163

E F

Material: PVC-U

Nominal Size (mm)

110 4S597 Colour: Grey

A (mm) 204

B (mm) 222

E (mm) 79

F (mm) 184

Single Branches D/SW Single Branch 871/2


l l l

Three solvent weld sockets Three closed boss socket positions on 110mm fitting 160mm fitting has no bosses Part Number 4S490 a 6S490 a Dimensions B (mm) 112 161

Material: PVC-U

Nominal Size (mm) 110 160 Colour: Black

A (mm) 159 222

C (mm) 152 240

38

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Single Branches continued SW/S Single Branch 871/2


l l

One plain end and two solvent weld sockets Three closed boss socket positions Part Number 4S290 a Dimensions B (mm) 112

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 159

C (mm) 152

D/SW Single 5-Boss Branch 871/2


l l

Three solvent weld sockets Five closed boss socket positions, of which two are positioned 84mm below the centre-line of the branch entry. These can be used for lowlevel waste connections Part Number Dimensions B (mm) C (mm) 108 84

Material: PVC-U

Nominal Size (mm)

A (mm) 139

D (mm) 99

110 4S495 a Colour: Black

D/SW Single Branch 45


l

Three solvent weld sockets Part Number 4S410 a Dimensions B (mm) 192

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 136

C (mm) 85

D/SW Unequal Single Branch 871/2


l l l

Two 160mm solvent weld sockets One 110mm solvent weld socket on the branch Two closed boss socket positions

Material: PVC-U

Nominal Size (mm) 160 Colour: Black

Part Number 6S498 a

A (mm) 167

Dimensions B (mm) 130

C (mm) 155

Double Branch D/SW Double Branch 871/2


l l l

Four solvent weld sockets Two closed boss socket positions Do NOT use for connecting back-to-back WCs in horizontal float installations: see relevant parts of BS EN 12056:2000 Part Number 4S430 a Dimensions B (mm) 110

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 141

C (mm) 144

Email: info@wavin.co.uk

www.osma.co.uk

39

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Corner Branch SW/S Corner Branch 871/2


l l

One plain end and three solvent weld sockets One closed boss socket position

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

Part Number 4S491 a

A (mm) 179

Dimensions B (mm) 113

C (mm) 144

Bossed Pipes D/SW Bossed Pipe


l l

Two solvent weld sockets. One closed boss socket position One solvent weld socket for 32mm [11/4"] or 40mm [11/2"] solvent weld plastic pipe to BS EN 1455-1/BS EN 1566-1

Material: PVC-U

Nominal Size (mm) 110x32 110x40 Colour: Black

Part Number 4S483 a 4S484 a

Dimensions A (mm) B (mm) 74 150 77 150

D/SW Bossed Pipe


l l

Two solvent weld sockets Three closed boss socket positions and one open to receive appropriate Boss Socket Adaptor Dimensions B (mm) 106

Material: PVC-U

Nominal Part Size (mm) Number 110 4S586 a Colours: Black, Grey

A (mm) 75

C (mm) 109

D/SW Short Bossed Pipe


l
BA

Three closed boss socket positions for use with the appropriate Boss Socket Adaptor Three closed 40mm spigot tail positions also allow for direct connection of 40mm solvent weld sockets Part Number Dimensions B (mm) C (mm) 43 124

Material: PVC-U

Nominal Size (mm)

A (mm) 56

D (mm) 74

110 4S588 a Colour: Black

S/SW Bossed Pipe


l l

One solvent weld socket and one push-fit ring-seal socket Three closed boss socket positions and one open to receive appropriate Boss Socket Adaptor Dimensions B (mm) 111

Material: PVC-U

Nominal Part Size (mm) Number 110 4S590 a Colours: Black, Grey

A (mm) 74

C (mm) 98

40

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Bossed Pipes continued SW/S Bossed Pipe


l l

One plain end and one solvent weld socket Three closed boss socket positions and one open to receive appropriate Boss Socket Adaptor Dimensions B (mm) 106

Material: PVC-U

Nominal Part Size (mm) Number 110 4S585 a Colours: Black, Grey

A (mm) 75

C (mm) 126

Strap Boss Strap Boss


l

For making side connections on BS EN 1329/BS EN 1453 plastic pipe after construction

Material: PVC-U

Nominal Size (mm) 110 Colours: Black, Grey, White

Part Number 4S319 a

Dimensions A (mm) 77

Boss Socket Adaptor SW/S Solvent Weld Boss Adaptor


l l l

Suitable for all OsmaSoil fittings incorporating boss socket positions Connects to 32mm [11/4"], 40mm [11/2"] or 50mm [2"] solvent weld plastic pipe to BS EN 1455-1/BS EN 1566-1 Horizontal adaptors have an inbuilt 21/2 fall

Material: PVC-U

Nominal Size (mm) 32 40 50 Colour: Black

Part Number 2S298 a 2S299 a 2S403 a

Dimensions A (mm) B (mm) 41 20 45 24 53 30

Access Fittings SW/S Bossed Access Pipe


l l l l

One plain end and one solvent weld socket Three closed boss socket positions Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83) Part Number 4S574 a 6S474 a Dimensions B (mm) 107 132

Material: PVC-U

Nominal Size (mm) 110 160 Colour: Black

A (mm) 75 124

C (mm) 118 150

Email: info@wavin.co.uk

www.osma.co.uk

41

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Access Fittings continued D/SW Bossed Access Pipe


l l l l

Two solvent weld sockets Three closed boss socket positions Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83) Part Number 4S474 a Dimensions B (mm) 107

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 85

C (mm) 114

D/SW Access Bend 871/2


l l l

Two solvent weld sockets Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83) Part Number 4S469 a Dimensions B (mm) 80

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

A (mm) 152

C (mm) 166

D/SW Access Bend 871/2


l l l l

Three solvent weld sockets Two closed boss socket positions Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

Part Number 4S493 a

A (mm) 159

Dimensions B (mm) 112

C (mm) 152

Access Saddle
l l l

For providing access to BS EN 1329/BS EN 1453 plastic pipe after construction, or where an access pipe or branch is not suitable Fitted with screwed access cover Spares available as follows: Access Liner 4S902, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U

Nominal Part Size (mm) Number 110 4S275 a Colours: Black, Grey

A (mm) 103

Dimensions B (mm) 35

C (mm) 35

42

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Solvent Weld Soil: OsmaSoil

Plugs P/E Access Plug


l l

Fits into a solvent weld socket to provide an access point Fitted with screwed access cover

Material: PVC-U

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 56 100 82 3S292 a 50 137 110 4S292 a 58 195 160 6S292 a Colours: All products available in Black, Grey 4S292 available in Black, Grey, White

SW/S Access Plug


l l

Glues over a pipe spigot to provide an access point Fitted with screwed access cover Part Number 4S492 a Dimensions A (mm) B (mm) 50 137

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

P/E Socket Plug


l l

One closed boss socket position Fits into a solvent weld socket to provide a connection point for a 32mm [11/4"], 40mm [11/2"] or 50mm [2"] waste-pipe connection when fitted with the appropriate boss socket adaptor

Material: PVC-U

Nominal Size (mm) 110 Colour: Black

Part Number 4S296 a

Dimensions A (mm) B (mm) 54 132

Email: info@wavin.co.uk

www.osma.co.uk

43

Product Selector

PVC-U Soil: WC Connectors

WC Manifold Branches (incorporating gasket) S/SW Manifold Branch Straight


l

One solvent weld and one push-fit socket (right hand illustrated) Part Number 4S601 a Dimensions Effective Length (mm) 132

Material: PVC-U

Nominal Size (mm) 110 Colour: White

A (mm) 180

S/SW Manifold Branch 8


l

One solvent weld and one push-fit socket (right hand illustrated) Part Number 4S602 a 4S612 a Dimensions B (mm) 16 16

Material: PVC-U

Nominal Size (mm) 110 LH 110 RH Colour: White

A (mm) 180 180

Effective Length (mm) 132 132

S/SW Manifold Branch 151/2


l

One solvent weld and one push-fit socket (right hand illustrated) Part Number 4S603 a 4S613 a Dimensions B (mm) 32 32

Material: PVC-U

Nominal Size (mm) 110 LH 110 RH Colour: White

A (mm) 180 180

Effective Length (mm) 132 132

S/SW Manifold Branch 23


l

One solvent weld and one push-fit socket (right hand illustrated) Part Number 4S604 a 4S614 a Dimensions B (mm) 48 48

Material: PVC-U

Nominal Size (mm) 110 LH 110 RH Colour: White

A (mm) 180 180

Effective Length (mm) 132 132

S/SW Manifold Branch 301/2


l

One solvent weld and one push-fit socket (right hand illustrated) Part Number 4S605 a 4S615 a Dimensions B (mm) 64 64

Material: PVC-U

Nominal Size (mm) 110 LH 110 RH Colour: White

A (mm) 180 180

Effective Length (mm) 132 132

NOTE: All Manifold Branches are fitted with a gasket for direct connection to the outlets of WCs manufactured to BS 5503 See Design and Installation Guide and BS EN 12056:2000 on the provision of access

44

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Soil: WC Connectors

WC Manifold Branches continued S/SW Manifold Branch 38


l

One solvent weld and one push-fit socket (right hand illustrated) Part Number 4S606 a 4S616 a Dimensions B (mm) 80 80

Material: PVC-U

Nominal Size (mm) 110 LH 110 RH Colour: White

A (mm) 180 180

Effective Length (mm) 132 132

WC Connectors (incorporating gasket) P/E Connector 21/2


l

One plain end

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S791 a

Dimensions A (mm) B (mm) 53 63

SW/S Connector 21/2


l

One solvent weld socket

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S792 a

Dimensions A (mm) B (mm) 53 63

P/E Connector 14
l

One plain end

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S711 a

Dimensions A (mm) B (mm) 53 63

SW/S Connector 14
l

One solvent weld socket

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S712 a

Dimensions A (mm) B (mm) 53 63

NOTE: Manifold Branches and WC Connectors are fitted with a gasket for direct connection to the outlets of WCs manufactured to BS 5503

Email: info@wavin.co.uk

www.osma.co.uk

45

Product Selector

PVC-U Soil: WC Connectors

WC Connectors continued P/E Connector 90


l

One plain end

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S771 a

Dimensions A (mm) B (mm) 109 173

SW/S Connector 90
l

One solvent weld socket

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S772 a

Dimensions A (mm) B (mm) 109 134

P/E Access Connector 90


l l l

One plain end Screwed access cover Spares available as follows: Access Liner 4S909, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S761 a

A (mm) 109

Dimensions B (mm) 80

C (mm) 173

SW/S Access Connector 90


l l l

One solvent weld socket Screwed access cover Spares available as follows: Access Liner 4S909, Access Cap 4S904, Access Cap Gasket 4S992 (page 83)

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S762 a

A (mm) 109

Dimensions B (mm) 80

C (mm) 134

NOTE: Manifold Branches and WC Connectors are fitted with a gasket for direct connection to the outlets of WCs manufactured to BS 5503 See Design and Installation Guide and BS EN 12056:2000 on the provision of access

46

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Soil: WC Connectors

WC Connectors (gasket to be fitted) P/E Connector Straight


l l

One plain end For direct connection to WCs to BS 1213 when fitted with the appropriate Gasket 4S120 or 4S121 (see below) Part Number 4S731 a Dimensions A (mm) 104

Material: PVC-U

Nominal Size (mm) 110 Colour: White

SW/S Connector Straight


l l

One solvent weld socket For direct connection to WCs to BS 1213 when fitted with the appropriate Gasket 4S120 or 4S121 (see below) Part Number 4S730 a Dimensions A (mm) 75

Material: PVC-U

Nominal Size (mm) 110 Colour: White

P/E Connector 871/2


l l

One plain end For direct connection to WCs to BS 1213 when fitted with the appropriate Gasket 4S120 or 4S121 (see below)

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S746 a

Dimensions A (mm) B (mm) 106 191

SW/S Connector 871/2


l l

One solvent weld socket For direct connection to WCs to BS 1213 when fitted with the appropriate Gasket 4S120 or 4S121 (see below)

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S745 a

Dimensions A (mm) B (mm) 106 77

WC Gasket S/S Access Pipe


l l

For use with Connectors 4S730, 4S731, 4S745 and 4S746 (see above) Connects to WC spigots as follows: 4S121 suits 4 to 41/4 spigots 4S120 suits 41/4 to 41/2 spigots Part Number 4S120 4S121 WC Spigot 4" to 41/4" 41/4" to 41/2"

Material: Synthetic Rubber

Nominal Size (mm) 110 110 Colour: White

Email: info@wavin.co.uk

www.osma.co.uk

47

Product Selector

PVC-U Soil: WC Connectors

WC Connectors (ancillaries) Plain-Ended Pipe


l

For use with WC Connectors (pages 45-47) where connection to SVP is visible Part Number 4S600 a Dimensions Length (mm) 600

Material: PVC-U

Nominal Size (mm) 110 Colour: White

S/S Long-Tail Bend 871/2


l l

For use with WC Connectors (pages 45-47) Do NOT use as a WC connector

Material: PVC-U

Nominal Size (mm) 110 Colour: White

Part Number 4S790 a

Dimensions A (mm) B (mm) 195 134

Easy-Fit Pan Connectors Easy-Fit Connector Straight


l l l l

For use where the WC outlet is horizontal to the branch connection Fitted with a gasket for direct connection to the outlets of WCs manufactured to BS 5503 Spigot end of 31/2" Connector WC003 incorporates gasket for direct insertion into plain end of 31/2" cast-iron pipe to BS 416 Spigot end of 4" Connector WC004 incorporates gasket for direct insertion into plain end of 4" pipe e.g. cast-iron, plastic or clay

Material: Polypropylene

Nominal Size (") 31/2" 4" Colour: White

Part Number WC003 WC004

Dimensions A (mm) B (mm) 116 52 116 52

Easy-Fit Connector Offset


l l l l

For use where the WC outlet is not directly in line with the branch connection. Correct alignment obtained by turning the connector Fitted with a gasket for direct connection to the outlets of WCs manufactured to BS 5503 Spigot end of 31/2" Connector WC003 incorporates gasket for direct insertion into plain end of 31/2" cast-iron pipe to BS 416 Spigot end of 4" Connector WC004 incorporates gasket for direct insertion into plain end of 4" pipe e.g. cast-iron, plastic or clay

Material: Polypropylene

Nominal Size (") 31/2" 4" Colour: White

Part Number WC203 WC204

A (mm) 116 116

Dimensions B (mm) 52 52

C (mm) 22 16

48

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Soil: WC Connectors

Easy-Fit Pan Connectors continued Easy-Fit Connector 14


l l l

Converts a horizontal WC outlet to an angle of 14 (76) Spigot end of 31/2" Connector WC143 incorporates gasket for direct insertion into plain end of 31/2" cast-iron pipe to BS 416 Spigot end of 4" Connector WC144 incorporates gasket for direct insertion into plain end of 4" pipe e.g. cast-iron, plastic or clay Part Number WC143 WC144 Dimensions B (mm) 52 52

Material: Polypropylene

Nominal Size (") 31/2" 4" Colour: White

A (mm) 73 73

C (mm) 67 67

Easy-Fit Connector 90
l l l

Converts a horizontal WC outlet to a left or right-hand S or P trap Can be cut to required length Spigot end incorporates gasket for direct insertion into plain end of 4" pipe e.g. cast-iron, plastic or clay Part Number WC904 Dimensions B (mm) 52

Material: Polypropylene

Nominal Size (") 4" Colour: White

A (mm) 107

C (mm) 236

Straight Extension Piece


l l l

One plain end Makes up the distance between any Easy-Fit Connector and soil or drain pipe connection Spigot end incorporates gasket for direct insertion into plain end of 4" pipe e.g. cast-iron, plastic or clay Part Number WC404 Dimensions A (mm) B (mm) 255 52

Material: Polypropylene

Nominal Size (") 4" Colour: White

NOTE: Easy-Fit Pan Connectors are fitted with a gasket for direct connection to the outlets of WCs manufactured to BS 5503

Email: info@wavin.co.uk

www.osma.co.uk

49

Product Selector

PVC-U Soil: Vents

Terminal Fittings Balloon Grating


Material: PVC-U

Nominal Part Size (mm) Number 82 3S302 110 4S302 160 6S302 Colours: All products available in Black, Grey 4S302 available in Black, Grey, White

Dimensions A (mm) 94 90 160

Weathering Collar
l l

Used to maintain a watertight seal between pipe and traditional lead or aluminium flashing To be solvent welded to pipe using Solvent Cement Filler 4S394

Material: PVC-U

Nominal Part Size (mm) Number 82 3S300 110 4S300 160 6S300 Colours: All products available in Grey 3S300 available in Black, Grey 4S300 available in Black, Grey, White

Dimensions A (mm) 62 86 58

Breather Vent
l l l

Used on mastic-asphalt or built-up roof finishes to allow moistureladen vapour to escape from the screed or roof deck Prevents distortion, blistering and deterioration of the finish Do NOT use for roof-void ventilation

Material: Propylene co-polymer

Nominal Size (mm) 110

Part Number 4S700

A (mm) 127

Dimensions B (mm) C (mm) 102 150

D (mm) 204

SW/S Vent Cowl


l l

Provides an alternative weather-proof termination for soil and vent pipe, or outlet for a mechanical-ventilation system Can be used in a vertical or horizontal position

Material: PVC-U

Nominal Part Size (mm) Number 110 4S310 a Colours: Black, Grey

A (mm) 172

Dimensions B (mm) 40

C (mm) 100

50

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-U Soil: Vents

Terminal Fittings continued SW/S Extract Valve


l l

Fitted with solvent weld socket Adjustable valve for use with a mechanical extract or ventilation system to control the air flow rate Nominal Size (mm) 110 Part Number 4S709 Dimensions A (mm) B (mm) 178 25-42, closed to fully open

Material: PVC-U and Polypropylene

Colour: White

Air Admittance Valves OsmaVent 40 Air Admittance Valve


l l l l

For direct connection to a 32mm [11/4"] or 40mm [11/2"] waste spigot Allows air into discharge pipe systems without allowing foul air to escape See page 98, BBA and BS EN 12056:2000 for ventilation requirements BBA certificated (Certificate No. 86/1643)

Material: ABS

Nominal Size (mm) 40 Colour: White

Part Number 4S303

A (mm) 66

Dimensions B (mm) 40

C (mm) 71

OsmaVent 110 Air Admittance Valve


l l l

l l l

A1 rated to BS EN 12380 For direct connection to a 110mm spigot on BS EN 1329/BS EN 1453 soil pipe For 82mm pipe, the rubber seal is removed, a short length of pipe welded to the socket, and the pipe fitted into a Socket 3S124 (page 19) Allows air into discharge pipe systems without allowing foul air to escape See page 98, BBA and BS EN 12056:2000 for ventilation requirements BBA certificated (Certificate No. 86/1643)

Material: ABS

Nominal Size (mm) 110 Colour: White

Part Number 4S304

A (mm) 130

Dimensions B (mm) 85

C (mm) 135

Domestic Air Admittance Valve


l
B

l
C

l l

A2 rated to BS EN 12380 For direct connection to a 110mm spigot on BS EN 1329/BS EN 1453 soil pipe Allows air into discharge pipe systems without allowing foul air to escape See page 98, BS EN 12056:2000 for ventilation requirements

Material: ABS

Nominal Size (mm) 110 Colour: Grey

Part Number 4S306

A (mm) 104

Dimensions B (mm) 66

C (mm) 116

Email: info@wavin.co.uk

www.osma.co.uk

51

Product Selector

PVC-U Soil: Vents

Pipe Flashings Varipitch Pipe Flashing for Flat Roofs


l

For use with 82mm and 110mm soil pipe to BS EN 1329 which penetrates a flat roof

Material: Aluminium base, EPDM Rubber cone

Nominal Size (mm) -

Part Number 4S281

Dimensions A (mm) B (mm) 400x400 85

Varipitch Pipe Flashing for Pitched Roofs


l

For use with 82mm and 110mm soil pipe to BS 1329 which penetrates a pitched roof

Material: Aluminium base, EPDM Rubber cone

Nominal Size (mm) -

Part Number 4S283 4S285

Dimensions A (mm) B (mm) 450x450 85 600x600 85

Fire Stop Seal Fire Stop Seal


l l

For use with 50mm, 82mm, 110mm and 160mm pipes which penetrate a compartment wall or floor See Design and Installation Guide and Building Regulations 1992, Approved Document B for fire stopping requirements Nominal Size (mm) 50 82 110 160 Part Number 2S001 3S001 4S001 6S001 Dimensions A (mm) 60 60 60 100

Material: Metal, containing an intumescent compound

52

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

ABS Solvent Weld Waste: OsmaWeld

Pipe Plain-Ended Pipe


Material: ABS

Nominal Part Dimensions Size (mm) Number Length (m) 3 32 4Z073 a 3 40 5Z073 a 3 50 2Z073 a 4 32 4Z074 a 4 40 5Z074 a 4 50 2Z074 a Colours: 4Z073, 5Z073 and 2Z073 available in Black, White 4Z074, 5Z074 and 2Z074 available in Grey

Bracket Pipe Bracket


l

For support centres, see pages 87 and 106


Dimensions B (mm) 67 73 79

Material: ABS

Nominal Part Size (mm) Number 32 4Z081 a 40 5Z081 a 50 2Z081 a Colours: Black, Grey, White

A (mm) 32 36 61

C (mm) 85 92 100

Sockets Double Socket


l l

For connecting lengths of ABS pipe Use Universal Connectors 4W102, 5W102 and 2W102 (page 62) for connecting to other materials
Dimensions A (mm) B (mm) 42 3 48 3 65 3

Material: ABS

Nominal Part Size (mm) Number 32 4Z104 40 5Z104 50 2Z104 Colours: Black, Grey, White

Expansion Socket
l l

For creating an expansion joint where provision for thermal movement is required. See page 86 for details Solvent weld socket and push-fit ring-seal socket Push-fit socket
connects to 32mm [11/4"], 40mm [11/2"] or 50mm [2"] pipe to BS EN 1451-1/BS EN 1455-1 and BS EN 1566-1

Also connects to copper pipe to BS 659 and BS 2871


Dimensions A (mm) B (mm) 72 3 78 3 93 3

Material: ABS

Nominal Part Size (mm) Number 32 4Z124 40 5Z124 50 2Z124 Colours: Black, Grey, White

Email: info@wavin.co.uk

www.osma.co.uk

53

Product Selector

ABS Solvent Weld Waste: OsmaWeld

Bends Knuckle Bend 90


Material: ABS

Nominal Size (mm) 32 40 50 Colours: Black, Grey, White

Part Number 4Z160 a 5Z160 a 2Z160 a

Dimensions A (mm) 41 46 64

Bend 871/2
Material: ABS

Nominal Part Size (mm) Number 32 4Z161 a 40 5Z161 a 50 2Z161 a Colours: Black, Grey, White

Dimensions A (mm) B (mm) 55 55 66 66 82 98

Bend 45
Material: ABS

Nominal Size (mm) 32 40 50 Colours: Black, Grey, White

Part Number 4Z163 a 5Z163 a 2Z163 a

Dimensions A (mm) 34 38 47

Long-Tail Bend 90
Material: ABS

Nominal Part Size (mm) Number 32 4Z260 40 5Z260 Colours: Black, Grey, White

Dimensions A (mm) B (mm) 40 85 49 92

Long-Tail Bend 871/2


l l l l

One plain end and one push-fit ring-seal socket Push-fit socket connects to 50mm [2"] pipe to BS EN 1451-1/
BS EN 1455-1 and BS EN 1566-1

Also connects to copper pipe to BS 659 and BS 2871 See Design and Installation Guide regarding thermal movement
Part Number 2Z359 Dimensions A (mm) B (mm) 80 152

Material: ABS

Nominal Size (mm) 50 Colour: Grey

54

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

ABS Solvent Weld Waste: OsmaWeld

Tees Tee 871/2


Material: ABS

Nominal Part Size (mm) Number 32 4Z190 a 40 5Z190 a 50 2Z190 a Colours: Grey, White

A (mm) 49 59 70

Dimensions B (mm) 40 46 56

C (mm) 55 59 76

Tee 45
Material: ABS

Nominal Size (mm) 32 40 50 Colours: Grey, White

Part Number 4Z210 a 5Z210 a 2Z210 a

Dimensions A (mm) B (mm) 56 112 61 126 76 146

Cross Cross 871/2


l

NOTE: Should not be used in a horizontal position


Dimensions B (mm) 52 62

Material: ABS

Nominal Part Size (mm) Number 40 5Z230 a 50 2Z230 a Colours: Grey, White

A (mm) 63 97

C (mm) 62 84

Plug P/E Access Plug


l l l

Fits into a solvent weld socket to provide an access point Fitted with screwed access cover See Design and Installation Guide and BS EN 12056:2000 regarding provision of access
Part Number 4Z292 5Z292 2Z292 Dimensions A (mm) B (mm) 41 20 48 23 60 32

Material: ABS

Nominal Size (mm) 32 40 50 Colours: Grey, White

Email: info@wavin.co.uk

www.osma.co.uk

55

Product Selector

ABS Solvent Weld Waste: OsmaWeld

Connectors and Adaptors Straight Tank Connector


l l l l

Flanged, threaded connector, and push-fit ring-seal socket Push-fit socket connects to 32mm [11/4"] or 40mm [11/2"] pipe to BS EN 1451-1/BS EN 1455-1 and BS EN 1566-1 Also connects to copper pipe to BS 659 and BS 2871 Includes fibre washers
Part Number 4Z185 a 5Z185 a Dimensions A (mm) 53 56

Material: Polypropylene

Nominal Size (mm) 32 40 Colours: Grey, White

Universal Connector
l l l

Two push-fit ring-seal sockets Connects to 32mm [11/4"] or 40mm [11/2"] pipe to BS EN 1451-1/BS EN 1455-1 and BS EN 1566-1 Also connects to copper pipe to BS 659 and BS 2871
Part Number 4W102 a 5W102 a 2W102 a Dimensions A (mm) B (mm) 89 3 95 3 105 3

Material: Polypropylene

Nominal Size (mm) 32 40 50 Colour: White

Cap and Liner


l l l

Threaded nut connector, and solvent weld socket Nut connects to 11/4" or 11/2" BSPT threaded waste outlets Solvent weld socket connects to 32mm [11/4"] or 40mm [11/2"] ABS or PVC-C solvent weld waste pipe to BS EN 1455-1 and
BS EN 1566-1

Material: PVC-U

Nominal Part Size (mm) Number 32 4Z364 a 40 5Z364 a Colours: All products available in White 5Z346 available in Black, White

Dimensions A (mm) 63 63

Male Iron Connector


l l l

Threaded spigot connector, and push-fit ring-seal socket Spigot connects to 11/4", 11/2" or 2" BSPT iron sockets Push-fit socket connects to 32mm [11/4"], 40mm [11/2"], or 50mm [2"] plastic waste pipe to BS EN 1451-1/BS EN 1455-1 and
BS EN 1566-1

Also connects to copper pipe to BS 659 and BS 2871


Part Number 4Z126 a 5Z126 a 2Z126 a Dimensions A (mm) 58 61 62

Material: Polypropylene

Nominal Size (mm) 32 40 50 Colours: Grey, White

56

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

ABS Solvent Weld Waste: OsmaWeld

Connectors and Adaptors continued Female Iron Connector


l l l

Threaded socket connector, and solvent weld socket Threaded socket connects to 11/4", 11/2" or 2" BSPT male iron spigot Solvent weld socket connects to 32mm [11/4"], 40mm [11/2"], or 50mm [2"] plastic waste pipe to BS EN 1455-1 and BS EN 1566-1
Part Number 4Z127 a 5Z127 a 2Z127 a Dimensions A (mm) 50 53 60

Material: ABS

Nominal Size (mm) 32 40 50 Colour: White

Male Iron Connector


l l l

Threaded spigot connector, and solvent weld socket Threaded spigot connects to 11/4", 11/2" or 2" BSPT female iron sockets Solvent weld socket connects to 32mm [11/4"], 40mm [11/2"], or 50mm [2"] plastic waste pipe to BS 5255
Dimensions A (mm) 44 47 53

Material: ABS

Nominal Part Size (mm) Number 32 4Z128 a 40 5Z128 a 50 2Z128 a Colours: All products available in Grey

Connector to BS 659 Copper Spigot


l l l l

Compression joint, and push-fit ring-seal socket Compression joint connects to 11/4" or 11/2" copper spigots to BS 659 Push-fit socket connects to 32mm [11/4"] or 40mm [11/2"] plastic waste pipe to BS EN 1451-1/BS EN 1455-1 and BS EN 1566-1 Also connects to copper pipe to BS 659 or BS 2871
Part Number 4Z184 a 5Z184 a Dimensions A (mm) 58 61

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: Grey

Connector to BS 659 Copper Compression Fitting


l l l l

Captive nut and ring-seal, and push-fit ring-seal socket Nut connects to 11/4 or 11/2" copper compression fittings to BS 659 Push-fit socket connects to 32mm [11/4"] or 40mm [11/2"] plastic waste pipe to BS EN 1451-1/BS EN 1455-1 and BS EN 1566-1 Also connects to copper pipe to BS 659 or BS 2871
Part Number 4Z365 a 5Z365 a Dimensions A (mm) 61 64

Material: Polypropylene

Nominal Size (mm) 32 40 Colours: Grey, White

Email: info@wavin.co.uk

www.osma.co.uk

57

Product Selector

ABS Solvent Weld Waste: OsmaWeld

Connectors and Adaptors continued Caulking Bush


l

One special end and one push-fit end


Part Number 2Z129 a Dimensions A (mm) 86

Material: ABS
A

Nominal Size (mm) 50 Colours: Black, Grey, White

Reducers Level Invert Reducer


l l l

One P/E and one solvent weld socket Allows connection of a 32mm [11/4"] waste pipe to either 40mm [11/2"] or 50mm [2"] S/W sockets Also allows a 40mm [11/2"] pipe to be connected to a 50mm [2"] S/W socket
Part Number 2Z088 a 2Z086 a Dimensions A (mm) B (mm) 33 4 33 4

Material: ABS

Nominal Size (mm) 50x32 50x40 Colours: Grey, White

Concentric Reducer
l l

Fits inside a 40mm [11/2"] solvent weld socket to BS EN 1455-1 Allows connection of a 32mm [11/4"] waste pipe to BS EN 1455-1
Part Number 5Z455 a Dimensions A (mm) 26

Material: ABS

Nominal Size (mm) 40x32 Colours: Grey, White

Waste to Overflow Reducer


l l

Fits inside a solvent weld waste socket to BS EN 1455-1 and BS EN 1566-1 Allows connection of 21.5mm pipe
Part Number 1E344 a 1E346 a Dimensions A (mm) B (mm) 19 36 23 43

Material: ABS
A

Nominal Size (mm) 32x21.5 40x21.5 Colours: Grey, White

58

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-C Solvent Weld Waste

Pipe Plain-Ended Pipe


Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Part Number 4M073 a 5M073 a 2M073 a

Dimensions Length (m) 3 3 3

Bracket Pipe Bracket


l

For support centres, see pages 87 and 106

Material: ABS

Nominal Part Size (mm) Number 32 4M081 a 40 5M081 a 50 2M081 a Colours: Black, White

A (mm) 31 34 58

Dimensions B (mm) 67 73 82

C (mm) 85 92 102

Sockets Double Socket


l l

For connecting lengths of PVC-C pipe Use Universal Connectors 4W102, 5W102 and 2W102 (page 64) for connecting to other materials
Part Number 4M104 a 5M104 a 2M104 a Dimensions A (mm) B (mm) 42 2 48 2 68 2

Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Expansion Socket
l l l l

For creating an expansion joint where provision for thermal movement is required. See page 86 for details Solvent weld socket and push-fit ring-seal socket Push-fit socket connects to 32mm [11/4"], 40mm [11/2"] or 50mm [2"] pipe to BS EN 1455-1 and BS EN 1566-1 Also connects to copper pipe to BS 659 and BS 2871

Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Part Number 4M124 a 5M124 a 2M124 a

Dimensions A (mm) B (mm) 64 3 65 3 72 3

Email: info@wavin.co.uk

www.osma.co.uk

59

Product Selector

PVC-C Solvent Weld Waste

Bends Knuckle Bend 90


Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Part Number 4M160 a 5M160 a 2M160 a

Dimensions A (mm) 40 52 60

Bend 871/2
Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Part Number 4M161 a 5M161 a 2M161 a

Dimensions A (mm) 47 58 72

Bend 45
Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Part Number 4M163 a 5M163 a 2M163 a

Dimensions A (mm) 31 43 48

Spigot Bend 90
Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Part Number 4M260 a 5M260 a 2M260 a

Dimensions A (mm) B (mm) 49 53 51 91 63 96

60

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PVC-C Solvent Weld Waste

Tees Tee 871/2


Material: PVC-C

Nominal Part Size (mm) Number 32 4M190 a 40 5M190 a 50 2M190 a Colours: Black, White

A (mm) 47 56 67

Dimensions B (mm) 43 51 62

C (mm) 51 59 68

Plug P/E Access Plug


l l l

Fits into a solvent weld socket to provide an access point Fitted with screwed access cover See Design and Installation Guide and BS EN 12056:2000 regarding provision of access
Part Number 4M292 a 5M292 a 2M292 a Dimensions A (mm) B (mm) 43 20 51 22 63.5 29

Material: PVC-C

Nominal Size (mm) 32 40 50 Colours: Black, White

Reducers Reducer
l l l

Fits inside a 40mm [11/2"] solvent weld socket to BS EN 1455-1 and


BS EN 1566-1

Allows connection of a 32mm [11/4"] waste pipe to either 40mm [11/2"] or 50mm [2"] pipe Also allows a 40mm [11/2"] pipe to be connected to a 50mm [2"] pipe
Part Number 5M455 a 2M458 a 2M456 a Dimensions A (mm) 23 30 30

Material: PVC-C

Nominal Size (mm) 40x32 50x32 50x40 Colours: Black, White

NOTE: For compatible connectors and adaptors see the ABS Solvent Weld range, pages 77-79

Email: info@wavin.co.uk

www.osma.co.uk

61

Product Selector

PP Push-fit Waste

Pipe Plain-Ended Pipe


Material: Polypropylene

Nominal Part Dimensions Size (mm) Number Length (m) 3 32 4W073 a 3 40 5W073 a 3 50 2W073 a Colours: All products available in Grey, White 4W073 and 5W073 available in Black, Grey, White

Bracket Pipe Bracket


l

For support centres, see page 87 and 106

Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 31 57 32 4W081 a 36 55 40 5W081 a 43 77 50 2W081 a Colours: All products available in Grey, White 4W081 and 5W081 available in Black, Grey, White

C (mm) 72 72 94

Socket Double Socket


l l

For connecting lengths of polypropylene pipe Universal Connectors 4W102 and 5W102 should be used or connecting to other materials

Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 32 4W105 a 68 2 79 2 40 5W105 a 71 2 50 2W105 a Colours: All products available in Grey, White 4W105 and 5W105 available in Black, Grey, White

62

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PP Push-fit Waste

Bends Knuckle Bend 90


Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) 58 32 4W160 a 60 40 5W160 a 70 50 2W160 a Colours: All products available in Grey, White 4W160 and 5W160 available in Black, Grey, White

Bend 871/2
Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) 62 32 4W161 a 77 40 5W161 a 93 50 2W161 a Colours: All products available in Grey, White 4W161 and 5W161 available in Black, Grey, White

Bend 45
Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) 32 4W163 a 48 50 40 5W163 a 49 50 2W163 a Colours: All products available in Grey, White 4W163 and 5W163 available in Black, Grey, White

Spigot Bend 30
A

Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 32 4W166 a 48 82 46 86 40 5W166 a 49 68 50 2W166 a Colours: All products available in Grey 5W166 available in Black, Grey, White

Spigot Bend 90
Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 32 4W260 a 61 67 60 75 40 5W260 a 68 65 50 2W260 a Colours: All products available in Grey, White 4W260 and 5W260 available in Black, Grey, White

Email: info@wavin.co.uk

www.osma.co.uk

63

Product Selector

PP Push-fit Waste

Tee Tee 871/2


Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 82 43 32 4W190 a 70 55 40 5W190 a 82 57 50 2W190 a Colours: All products available in Grey, White 4W190 and 5W190 available in Black, Grey, White

C (mm) 85 70 79

Plug Access Plug


B

l l

Fits into a push-fit ring-seal socket to provide an access point See Design and Installation Guide and BS EN 12056:2000 regarding provision of access

Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 43 25 32 4W292 a 55 26 40 5W292 a 69 26 50 2W292 a Colours: All products available in Grey, White 4W292 and 5W292 available in Black, Grey, White

Connectors Universal Connector


l l l

Two push-fit ring-seal sockets Connects to 32mm [11/4"] or 40mm [11/2"] pipe to BS EN 1451-1/
BS EN 1455-1 and BS EN 1566-1

Also connects to copper pipe to BS 659 and BS 2871

Material: Polypropylene

Nominal Part Dimensions Size (mm) Number A (mm) B (mm) 32 4W102 a 89 3 95 3 40 5W102 a 105 3 50 2W102 a Colours: All products available in Grey 4W102 and 5W102 available in Black, Grey, White

Tank Connector
l
A

Push-fit socket connects to waste pipe to BS EN 1455-1/ BS EN 1451-1 and BS EN 1566-1 Also connects to copper pipe to BS 659 and BS 2871
Part Number 4W185 a 5W185 a Dimensions A (mm) 65 65

Material: Polypropylene

Nominal Size (mm) 32 40 Colours: Black, Grey

64

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PP Push-fit Waste

Connectors continued Cap and Lining Socket


l

Threaded socket and push-fit end


Part Number 4W156 a 5W156 a Dimensions A (mm) 66 66

Material: Polypropylene
A

Nominal Size (mm) 32 40 Colour: White

Cap and Lining Spigot


l
A

Threaded socket and plain end

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Part Number 4W157 a 5W157 a

Dimensions A (mm) 84 84

Reducers Reducer
l l

Spigot connects to 40mm [11/2"] push-fit ring-seal socket to BS EN 1451-1 Socket connects to 32mm [11/4"] waste pipe to BS EN 1451-1
Part Number 5W084 a Dimensions A (mm) 44

Material: Polypropylene

Nominal Size (mm) 40x32 Colours: Black, Grey, White

Level Invert Reducer


l l

Spigot connects to 50mm [2"] push-fit ring-seal socket to BS EN 1451-1 Socket connects to 32mm [11/4"] or 40mm [11/2"] waste pipe to BS EN 1451-1
Part Number 2W088 a 2W086 a Dimensions A (mm) 71 71

Material: Polypropylene

Nominal Size (mm) 50x32 50x40 Colours: Grey, White

Waste to Overflow Reducer


l l

Fits inside a push-fit waste socket to BS EN 1451-1 Allows connection of 21.5mm pipe
Part Number 1C344 1C346 Dimensions B (mm) 16 16

Material: ABS
A

Nominal Size (mm) 32x21.5 40x21.5 Colour: White

A (mm) 26 39

C (mm) 34 40

Email: info@wavin.co.uk

www.osma.co.uk

65

Product Selector

Waste: Vents

Air Admittance Valve OsmaVent 40 Air Admittance Valve


l l l l

For direct connection to a 32mm [11/4"] or 40mm [11/2"] waste spigot Allows air into discharge pipe systems without allowing foul air to escape See page 98, BBA and BS EN 12056:2000 for ventilation requirements BBA certificated (Certificate No. 86/1643)

Material: ABS

Nominal Size (mm) 40 Colour: White

Part Number 4S303

A (mm) 66

Dimensions B (mm) 40

C (mm) 71

Fire Stop Seal Fire Stop Seal


l l

For use with 50mm, 82mm, 110mm and 160mm pipes which penetrate a compartment wall or floor See pages 101 and 109, Building Regulations 1992, Approved Document B for fire stopping requirements Nominal Size (mm) 50 82 110 160 Part Number 2S001 3S001 4S001 6S001 Dimensions A (mm) 60 60 60 100

Material: Metal, containing an intumescent compound

66

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PP Waste: V-Joint Traps

90 All-Fit Conversion Bend 90 All-Fit Conversion Bend


l l

Converts a P Trap Outlet to an S Trap Outlet Connects to 32mm [11/4] or 40mm [11/2"] pipe to BS EN 1451-1/ BS 5254 and BS 5255, or to copper pipe to BS 659 and BS 2871
Part Number 4A830 5A830 Dimensions A (mm) B (mm) 69 67 71 71

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Bottle Traps Bottle Trap 38mm seal


l

For use with appliances with trailing waste discharge, installed on ground floors and discharging to external gullies (refer to BS EN 12056:2000) Part Number 4V809 5V809 Dimensions B (mm) 60 68

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

A (mm) 120 130

C (mm) 78 93

Bottle Trap 75mm seal


Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Part Number 4V812 5V812

A (mm) 172 175

Dimensions B (mm) C (mm) 72 76 47 50

D (mm) 66 74

Anti-Syphon Bottle Trap 75mm seal


Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Part Number 4V814 5V814

A (mm) 172 190

Dimensions B (mm) C (mm) 72 80 48 50

D (mm) 62 72

Re-Sealing Bottle Trap 75mm seal


l l

Designed to prevent loss of seal where either self-siphonage or induced siphonage is likely In some instances, can be used as an alternative to branch ventilation pipes (refer to BS EN 12056:2000) Part Number 4V816 5V816 Dimensions B (mm) C (mm) 67 73 50 50

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

A (mm) 178 185

D (mm) 75 82

Email: info@wavin.co.uk

www.osma.co.uk

67

Product Selector

PP Waste: V-Joint Traps

Bottle Traps continued Adjustable Bottle Trap 75mm seal


B

Material: Polypropylene
C

Nominal Size (mm) 32 40 Colour: White

Part Number 4V808 5V808

A Min (mm) 185 180

A Min (mm) 290 270

Dimensions B C (mm) (mm) 75 62 77 65

D (mm) 62 72

Tubular Traps Tubular P Trap - 75mm seal


Material: Polypropylene

Nominal Size (mm) 32 40 50 Colour: White

Part Number 4V801 5V801 2V801

A (mm) 145 150 180

Dimensions B (mm) C (mm) 120 138 165 57 60 85

D (mm) 57 63 80

Adjustable Tubular P Trap 75mm seal


l

Incorporates adjustable inlet allowing the height of the trap to be varied

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Part Number 4V807 5V807

A Min (mm) 140 155

Dimensions A Max B (mm) (mm) 230 57 225 57

C (mm) 120 138

Running P Trap 75mm seal


l

Both inlet and outlet incorporate V joint connections

Material: Polypropylene

Nominal Size (mm) 32 40 50 Colour: White

Part Number 4V805 5V805 2V805

A (mm) 125 140 160

Dimensions B (mm) C (mm) 57 62 76 125 140 160

D (mm) 131 146 170

Tubular S Trap 75mm seal


Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Part Number 4V803 5V803

A (mm) 145 150

Dimensions B (mm) 57 63

C (mm) 57 63

68

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PP Waste: V-Joint Traps

Tubular Traps continued Variform Trap 75mm seal


l

Particularly useful for replacement, maintenance and improvement work where connection between two fixed points is required Part Number 4V804 5V804 Dimensions B (mm) 155-211 164-220

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

A (mm) 146-224 152-234

C (mm) 56-134 60-142

Straight Through Trap 75mm seal


l l

Incorporates a cleaning eye Particularly useful for wash basin pedestals where the waste pipe can be concealed

Material: Polypropylene

Nominal Size (mm) 32 Colour: White

Part Number 4V825

A (mm) 240

Dimensions B (mm) 44

C (mm) 88

Bath Traps Bath Trap 38mm seal


l l

For use with appliances trailing waste discharge and installed on ground floors discharging to an external gully Refer also to BS EN 12056:2000

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

Part Number 5V802

A (mm) 85

Dimensions B (mm) 170

C (mm) 95

Bath Trap Shallow seal


Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Part Number 4V806 5V806

A (mm) 65 110

Dimensions B (mm) 130 150

C (mm) 60 66

Bath Trap 75mm seal


l

Incorporates screwed access cover for maintenance

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

Part Number 5V846

A (mm) 110

Dimensions B (mm) 195

C (mm) 130

Email: info@wavin.co.uk

www.osma.co.uk

69

Product Selector

PP Waste: V-Joint Traps

Bath Traps continued Bath Trap and Overflow 75mm seal


l

Incorporates: - flexible overflow connection - chromium-plated rose - chain for the waste plug

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

Part Number 5V848

A (mm) 110

Dimensions B (mm) 195

C (mm) 130

Anti-Syphon Bath Trap 75mm seal


l

40mm Anti-Syphon Bath Trap with 50mm water seal


Part Number 5V842 Dimensions A (mm) B (mm) 85 255

Material: Polypropylene
A

Nominal Size (mm) 40 Colour: White

Bath Trap with Extended Body 60mm seal


l

B C D

Incorporates: - flexible overflow connection - chromium-plated rose - chain for the waste plug

Material: Polypropylene

Nominal Size (mm) 40 Colour: White


A

Part Number 5V860

A (mm) 85

B (mm) 210

Dimensions C D M in (mm) (mm) 150 300

D Max (mm) 500

Shower Traps Shower Trap 19mm seal


l l

Includes a dip tube, removable from top Allows for easy cleaning
Part Number 5V823 Dimensions A (mm) B (mm) 90 42

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

Shower Trap 50mm seal


l l

Includes a dip tube, removable from top Allows for easy cleaning
Part Number 5V824 Dimensions A (mm) B (mm) 118 42

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

70

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PP Waste: V-Joint Traps

Shower Gullies Shower Gully for Tiled Floor


B C
l

Allows flush installation in tiled finish

Material: ABS

Nominal Size (mm) 50 Colour: White

Part Number 2V500

A (mm) 130

Dimensions B (mm) 200

C (mm) 93

A B

Stainless Steel Adaptor for 2V500 (above)


Material: Inlet grill stainless-steel; Top cover ABS

Nominal Size (mm) 50 Colour: White

Part Number 2V501

Dimensions A (mm) B (mm) 156 113

B C

Shower Gully for Sheet Floor


l

Allows flush installation in sheet finish

Material: ABS
A

Nominal Size (mm) 50 Colour: White

Part Number 2V510

A (mm) 130

Dimensions B (mm) 200

C (mm) 120

B C

Shower Gully for Sheet Floor


l

Allows flush installation in sheet finish

Material: Inlet grill stainless-steel; Top cover ABS

Nominal Size (mm) 50 Colour: White

Part Number 2V511

A (mm) 175

Dimensions B (mm) 200

C (mm) 120

WasteFlow Units Bath Trap and WasteFlow Unit 75mm seal


l l l

Combined means of disposal of overflow discharges from both cold water storage and WC cisterns Eliminates need for external overflow pipes Incorporates: - flexible overflow/ WasteFlow unit - chromium-plated rose - chain for the waste plug Incorporates 11/2" BSPT inlet for Overflow Connectors 5V835, 5V836 or 5V837

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

Part Number 5V859

A (mm) 27

Dimensions B (mm) C (mm) 111 90

D (mm) 85

Email: info@wavin.co.uk

www.osma.co.uk

71

Product Selector

PP Waste: V-Joint Traps

WasteFlow Units continued WasteFlow Tee 2-way with 1 plug


l l

When fitted to Bath Trap 5V859 (page 71), allows connection of up to two 19mm [3/4"] Push-Fit Overflow pipes Will also accept Solvent Weld Overflow pipe when used with fitting 1O158 or 1O159 (page 79) with one connector blanked off
Part Number 5V836 Dimensions A (mm) B (mm) 55 95

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

WasteFlow Tee 4-way with 3 plugs


l l

When fitted to Bath Trap 5V859 (page 71), allows connection of up to four 19mm [3/4"] Push-Fit Overflow pipes Will also accept Solvent Weld Overflow pipe when used with fitting 1O158 or 1O159 (page 79) with three connectors blanked off
Part Number 5V837 Dimensions A (mm) B (mm) 55 95

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

Washing Machine Traps Washing Machine Half Trap 75mm seal


l l

For direct connection to 3/4" hose from washing machines or dishwashers Hose adaptor can also be cut back to provide 3/4" or 1" BSPT male thread Part Number 5V864 Dimensions B (mm) C (mm) 140 60

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

A (mm) 185

D (mm) 63

Adjustable Sink Trap 75mm seal


l

For direct connection of one or two 3/4" hoses from washing machines or dishwashers

Material: Polypropylene
C A

Nominal Size (mm) 40 Colour: White

Part Number 5V869

A Min (mm) 195

Dimensions A Max B (mm) (mm) 260 63

C (mm) 65

72

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PP Waste: V-Joint Traps

Washing Machine Traps continued Tubular Swivel Trap


B C

40mm x 75mm adjustable with 21.5mm connection Part Number 5V407 Dimensions B (mm) C (mm) 63 68

Material: Polypropylene

Nominal Size (mm)


A D

A (mm) 224

D (mm) 130

40 Colour: White

Washing Machine Trap with Standpipe 75mm seal


l l

Machine hose hooks into top of standpipe to provide an air break Supplied with two pipe brackets Part Number 5V870 Dimensions B (mm) C (mm) 60 63

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

A (mm) 700

D (mm) 140

Washing Machine Tee Piece


l l

Fits between the sink and an existing trap Allows direct connection of a 3/4" hose from washing machines or dishwashers
Part Number 5V871 Dimensions A (mm) B (mm) 70 54

Material: Polypropylene

Nominal Size (mm) 40 Colour: White

Email: info@wavin.co.uk

www.osma.co.uk

73

Product Selector

PP Waste: V-Joint Traps

Reducers Outlet Reducer


l

To reduce the spigot diameter of an existing 40mm [11/2"] BSPT waste outlet to 32mm [11/4"] BSPT waste outlet Part Number 5V612

Material: Polypropylene

Nominal Size (mm) 40x32 Colour: White

Inlet Reducer
l

To reduce the trap inlet diameter to allow a 40mm [11/2"] BSPT waste outlet to 32mm [11/4"] BSPT waste outlet Part Number 5V616

Material: Polypropylene

Nominal Size (mm) 40x32 Colour: White

Flexible Connectors Flexible Spigot Connector


l

Provided with a captive nut at one end and a 32mm [11/4"] or 40mm [11/2"] spigot at the other Part Number 4V901 5V901 Dimensions Length (mm) 450 450

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Flexible Spigot Connector


l

Provided with a captive nut at one end and a 32mm [11/4"] or 40mm [11/2"] spigot at the other Part Number 4V902 5V902 Dimensions Length (mm) 165-290 165-290

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Flexible Socket Connector


l

Provided with a captive nut at each end

Material: Polypropylene

Nominal Size (mm) 32 40 Colour: White

Part Number 4V903 5V903

Dimensions Length (mm) 165-290 165-290

74

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

Condensate Drainage

Soakaway Soakaway
l

110mm OD with 21.5mm, 32mm, 40mm pipe connections

Material: Polypropylene

Nominal Size (mm) 110 Colour: Grey

Part Number 1V403

Dimensions A (mm) B (mm) 325 120

Connectors and Adaptors Pipe Clamp


B

32/40mm waste and 21.5mm connection

Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Part Number 1V402

A (mm) 130

Dimensions B (mm) C (mm) 48 71

D (mm) 78

Pipe Boss Connector


A
l

For connection of 21.5mm pipe to soil and rainwater pipe

Material: Polypropylene
B

Nominal Size (mm) 21.5 Colour: White

Part Number 1V401

Dimensions A (mm) B (mm) 70 60

Tubular Swivel Trap


l

40mm x 75mm adjustable with 21.5mm connection Part Number 5V407 Dimensions B (mm) C (mm) 63 68

Material: Polypropylene

A D

Nominal Size (mm) 40 Colour: White

A (mm) 224

D (mm) 130

Tubular Swivel Trap


l

40mm x 75mm adjustable with 21.5mm connection and washing machine nozzle Part Number Dimensions C D (mm) (mm) 61 130

Material: Polypropylene
E

Nominal Size (mm)

A
D

40 5V468 Colour: White

A (mm) 188

B (mm) 130

E (mm) 90

Email: info@wavin.co.uk

www.osma.co.uk

75

Product Selector

Condensate Drainage

Connectors and Adaptors continued Non-return Valve


l
A

For in-line vertical connection

Material: Polypropylene
B

Nominal Size (mm) 21.5 Colour: White

Part Number 1V400

Dimensions A (mm) B (mm) 109 49

Straight Connector
A

For 3/4" flexible tube x 21.5mm rigid pipe

Material: Polypropylene
B

Nominal Size (mm) 21.5 Colour: White

Part Number 1V404

Dimensions A (mm) B (mm) 67 40

Reducer
l

To 21.5mm pipe

Material: Synthetic rubber

Nominal Size (mm) 32 Colour: White

Part Number 4Z343

Dimensions A (mm) B (mm) 40 28

76

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

ABS & PVC-U Solvent Weld Overflow

Pipe Plain-Ended Pipe


Material: PVC-U

Nominal Size (mm) 21.5 Colour: White

Part Number 1E074

Dimensions Length (m) 4

Pipe Clip Pipe Clip


B

For support centres, see pages 87 and 106


Part Number 1E082 Dimensions A (mm) B (mm) 28 16

Material: PVC-U
A

Nominal Size (mm) 21.5 Colour: White

Socket Double Socket


Material: ABS

Nominal Size (mm) 21.5 Colour: White

Part Number 1E104

Dimensions A (mm) B (mm) 53 2

Bends Bend 90
Material: ABS

Nominal Size (mm) 21.5 Colour: White

Part Number 1E160

Dimensions A (mm) 39

Bend 45
Material: ABS

Nominal Size (mm) 21.5 Colour: White

Part Number 1E166

Dimensions A (mm) 33

Bend 25
Material: ABS
A

Nominal Size (mm) 21.5 Colour: White

Part Number 1E163

Dimensions A (mm) 34

Email: info@wavin.co.uk

www.osma.co.uk

77

Product Selector

ABS & PVC-U Solvent Weld Overflow

Tee Tee 90
Material: ABS

Nominal Size (mm) 21.5 Colour: White

Part Number 1E190

Dimensions A (mm) B (mm) 39 39

Connectors Straight Tank Connector


l l

Flanged, threaded connector at one end, 19mm solvent weld socket at the other Includes two gaskets for connecting to tanks or cisterns
Part Number 1E129 Dimensions A (mm) 27

Material: ABS

Nominal Size (mm) 21.5 Colour: White

Bent Tank Connector 90


l l

Flanged, threaded connector at one end, 19mm solvent weld socket at the other Includes two gaskets for connecting to tanks or cisterns
Part Number 1E139 Dimensions A (mm) B (mm) 45 42

Material: ABS

Nominal Size (mm) 21.5 Colour: White

Reducers Waste to Overflow Reducer


l l

Fits inside a solvent weld waste socket to BS EN 1455-1 and BS EN 1566-1 Allows connection of 21.5mm pipe
Part Number 1E344 a 1E346 a Dimensions A (mm) B (mm) 19 36 23 43

Material: ABS
A

Nominal Size (mm) 32x21.5 40x21.5 Colours: Grey, White

78

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

ABS & PVC-U Solvent Weld Overflow

Adaptors Cap and Lining


l l

Threaded nut connector at one end, 21.5mm solvent weld socket at the other The nut connects to 3/4" BSPT male thread
Part Number 1E156 Dimensions A (mm) 54

Material: ABS

Nominal Size (mm) 21.5 Colour: White

Compression Fitting Adaptor Straight


l

Spigot connects to compression fitting manufactured to BS 659, socket connects to 21.5mm [3/4"] PVC-U Solvent Weld Overflow Pipe Can also connect PVC-U Solvent Weld Overflow to Tundish 1O149 or WasteFlow Units 5V835, 5V836, 5V837

Material: ABS

Nominal Size (mm) 21.5 Colour: White

Part Number 1O158

Dimensions A (mm) 30

Compression Fitting Adaptor 90


l

Spigot connects to compression fitting manufactured to BS 659, socket connects to 21.5mm [3/4"] PVC-U Solvent Weld Overflow Pipe Can also connect PVC-U Solvent Weld Overflow to Tundish 1O149 or WasteFlow Units 5V835, 5V836, 5V837

Material: ABS

Nominal Size (mm) 21.5 Colour: White

Part Number 1O159

Dimensions A (mm) B (mm) 31 47

Tundish Tundish
l l

Provides an air break Used with connectors 1O158 or 1O159 (above)


Part Number 1O149 Dimensions A (mm) B (mm) 28 88

Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Email: info@wavin.co.uk

www.osma.co.uk

79

Product Selector

PP Push-fit Overflow

Pipe Plain-Ended Pipe


Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Part Number 1C074

Dimensions Length (m) 4

Pipe Clip Pipe Clip


l

For support centres, see pages 87 and 106


Part Number 1C082 Dimensions A (mm) B (mm) 28 16

Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Socket Double Socket


Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Part Number 1C104

Dimensions A (mm) B (mm) 51 3

Bends Bend 90
Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Part Number 1C160

Dimensions A (mm) 37

Bend 45
Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Part Number 1C163

Dimensions A (mm) 35

Tee Tee 90
Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Part Number 1C190

Dimensions A (mm) B (mm) 37 37

80

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

PP Push-fit Overflow

Connector Bent Tank Connector 90


l l l

Flanged, threaded connector at one end, 19mm push-fit socket at the other Includes two gaskets for connecting to tanks or cisterns Bend can be cut off to convert to straight tank connector
Part Number 1C139 Dimensions A (mm) B (mm) 37 18

Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Reducers Waste to Overflow Reducer


B

l l

Fits inside a push-fit waste socket to BS EN 1451-1 Allows connection of 21.5mm pipe
Part Number 1C344 1C346 Dimensions B (mm) 16 16

Material: ABS

Nominal Size (mm) 32x21.5 40x21.5 Colour: White

A (mm) 26 39

C (mm) 34 40

Tundish Tundish
l l

Provides an air break Connects directly to PP Push-Fit Overflow pipework


Part Number 1O149 Dimensions A (mm) B (mm) 28 88

Material: Polypropylene

Nominal Size (mm) 21.5 Colour: White

Email: info@wavin.co.uk

www.osma.co.uk

81

Product Selector

Soil and Waste: Ancillaries

Spares

Cleaner Degreasing Cleaner No. 1


l l l

Use for cleaning solvent weld joints prior to assembly. See Design and Installation Guide for safety information See page 105 for usage allowances Size (ml) 125 250 Part Number 4S379 4S380

Solvent Cement Solvent Cement No. 2


l l l

Use for making solvent weld joints See Design and Installation Guide for safety information See page 105 for usage allowances Size (ml) 125 250 500 Part Number 4S383 a 4S384 a 4S385 a

Solvent Cement Filler


l l

See Design and Installation Guide for safety information See page 105 for usage allowances Size (g) 200 Part Number 4S384

Lubricant Silicone Lubricant


l l
Silicone Lubricant Spray

Use to aid assembly of ring-seal socket-and-spigot joints See page 104 for usage allowances Size (g) 50 g tube 400ml spray can Part Number 4S391 4S392

Spares for Push-fit Soil Snap Cap


l

Snap-on cap which retains the sealing ring in all standard OSMA ring-seal fittings Part Number 3S116 4S116 6S116

Material: Polypropylene

Nominal Size (mm) 82 110 160 Colours: All products available in Grey 3S116 available in Black, Grey 4S116 available in Black, Grey, White

82

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Product Selector

Soil and Waste: Spares

Spares for Push-fit Soil Sealing Ring


l

Synthetic rubber sealing ring for all standard OSMA ring-seal fittings Nominal Size (mm) 82 110 160 Part Number 3S130 4S130 6S130

Material: EPDM

Access Liner
l l

For use with 4S274/275/374 or 4S502 NOT for use with 4S169/369 or 4S469

Material: PVC-U

Nominal Size (mm) 110 Colour: Grey

Part Number 4S902

Access Liner
l l

For use with 4S169/369 or 4S469 NOT for use with 4S274/275/374 or 4S502

Material: PVC-U

Nominal Size (mm) 110 Colours: Black, Grey, White

Part Number 4S909

Access Cap
l l

For use with 4S274/275/374/502/169/369 or 4S469 NOT for use with 4S292

Material: PVC-U

Nominal Size (mm) 110 Colours: Black, Grey, White

Part Number 4S904

Access Cap Gasket


Material: EPDM

Nominal Size (mm) 110 Colour: Grey

Part Number 4S992

Email: info@wavin.co.uk

www.osma.co.uk

83

Design

Typical Assembly

Typical Assembly
Fig. 1 Typical stack assembly Ring-Seal system
4S302 4S302

Fig. 2 Typical stack assembly Solvent Weld system

4S283 4S283

4S440 4S450 4S440 4S082 4S082 4S450

4S583 4S483

4S083 4S083 4S395 2S399 SW160 4S495 2S299 5Z260

4S083 2S399 4S590 4S474 4S416 4S083 2S299

4S275

84

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Applications

Pipe Sizing

Applications General principles


OSMA Soil & Waste systems are designed to convey soil drainage and waste safely away from appliances to a soil stack or drain (see Fig. 3). The systems are suitable for above ground sanitary fittings and appliances in domestic, commercial and public buildings. However, special requirements may apply to some trade wastes including:
l l 4S082 Basin 4S190 WC Bath 4S445

Fig. 3 Typical layout for Soil & Waste


4S302

High temperature and chemical effluent Discharges from hospitals and laboratories

For maximum operating temperatures, see Materials: Properties and Performance, page 34.
4S275 Sink (to stack or gully) 4S584

OSMA Below Ground Drainage

OSMA Bottle Gully

Pipe Sizing Soil systems


Stack The internal diameter of a discharge stack should not be less than that of the largest trap or appliance discharging into it. EXAMPLE: If a WC trap diameter is 110mm, the discharge stack must be minimum diameter 110mm. Vent Dry sections of vent pipe should typically have the same internal diameter as the discharge stack. However, for 1- or 2-storey houses, the dry section may be 75mm diameter without affecting performance. Fig. 4 Combined waste connection to soil stack
Basin 2W088 Bath 2S402 4S190 4V816 32mm [1] pipe

Waste systems
The internal diameter of the waste pipe should not be less than that of the largest trap or appliance discharging into it. Minimum tubular trap sizes are given in Table 19 opposite. Combined waste systems Waste pipe diameters should be increased at the point where waste from two appliances meet (see Fig. 4).

Table 19: Minimum Tubular Trap Sizes Type of Appliances Wash Basin Bidet Sink Bath Shower Urinal (bowl) Urinal (slabs 1-7) Washing Machine Size of Trap 32 32 40 40 40 40 65 40

50mm [2] pipe

5V848

32mm [1] 2W190 pipe 2W086 5W081

2W081

110mm Single Socketed Pipe

Email: info@wavin.co.uk

www.osma.co.uk

85

Design

Pipe Runs

Thermal Movement

Maximum Pipe Runs Waste systems


The maximum recommended pipe run from trap to stack, serving single or combined appliances, is as follows: 3m for 40mm pipe 4m for 50mm pipe If the pipe run exceeds the recommended maximum lengths above, an increased risk of blockage and/or siphonage may occur:
l l l

The pipe run must be vented to prevent self-siphonage or induced siphonage. See page 98 for details of use of OSMA Air Admittance Valve 4S303 Access to be provided wherever possible Provision for thermal movement is required in the case of Solvent Weld systems (see below)

Thermal Movement Push-Fit systems


Correctly made and anchored ring-seal/ push-fit joints will accommodate thermal movement with no requirement for expansion fittings. Fig. 5 Thermal movement requirements for a Solvent Weld Soil system

Solvent Weld systems


(see Fig. 5) Provision for thermal movement is required:
l

For all pipe runs over 3m for 32, 40 or 50mm pipe 4m for 82, 110 or 160mm pipe Between any two fixed points 1m or more apart
Expansion above highest fixed point taken up through roof.

Fixed points include:


l l l

Fittings supported by socket brackets Changes of direction Branches from other appliances

Fixed point due to socket bracket.

Pipe brackets allow the movement of pipework between fixed points whilst keeping the pipework steady. The following components are available for the creation of thermal expansion joints:
Expansion between fixed point and drain connection taken up within drain socket.

COMPONENTS
PVC-U Solvent Weld Soil system: Expansion Cap 4S416 (110mm) and 6S416 (160mm) ABS Solvent Weld Waste system: Expansion Socket 4Z/5Z/2Z124 PVC-C Solvent Weld Waste system: Expansion Socket 4M/5M/2M124

If a solvent welded fitting is provided on the ground floor it should be fitted with an expansion socket.

86

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Pipe Support

Access

Pipe Support Support Centres


Pipe should be supported in accordance with Table 20 below showing maximum support centres for pipes installed vertically and horizontally. Brackets are available to meet all support requirements for OSMA Soil & Waste systems.

Suspended pipework
Bracket assemblies are available for suspended sanitary and drainage installations within a building. The Suspended Bracketing system (see Fig. 6) offers socket or pipe bracketing in 110mm and 160mm sizes and is adjustable to accommodate pipe falls. For installation details see page 106.

Fig. 6 Suspended bracketing socket


support
Adjustable brace Threaded bracket

Threaded rod

Bracket plate

Table 20: Maximum Pipe Support Centres Pipe Size (mm) 19 32 40 50 82 110 160 Centres (m) Vertical Horizontal 0.5 0.5 1.2 0.5 1.2 0.5 1.2 0.6 2 1 2 1 2 1.2

Note: Not suitable for use in damp inaccessible voids

Pipe/socket bracket

Access
Access points should be provided to enable all pipework to be tested and maintained effectively. To facilitate use of testing and cleaning equipment, access points should be positioned so that:
l

Access to ranges of WCs


Branch pipes serving ranges of WCs should incorporate access points:
l l

Fig. 7 Access Saddle (4S275)


Saddle

At the head of the run Wherever the pipe changes direction

Insert and seal Cap

Building structures such as walls and ducts do not impede use of the equipment No danger or nuisance is likely if leakage should occur

Venting of these branch pipes is not normally necessary, except:


l l

Where more than 8 WCs are being served Where there are several changes of direction

This can be achieved by positioning access points above the spill-over levels of any pipework which may be affected by blockages.

Urinals
Waste pipe serving urinals can be subject to build up of deposits, especially in areas of hard water:
l

Access fittings
A wide range of access fittings are available, including access pipes, bends and branches. See the Product Selector section for full details. Access may also be created at an appropriate position in 110mm pipe by installing Access Saddle 4S275 (see Fig. 7). This fitting can also be installed post construction. For installation details see page 108.

Make provision for access to all areas of the waste system Keep pipe runs as short as possible: less than 3m is recommended

To increase self-cleansing, it is advisable for wash basins with resealing bottle traps to discharge into the waste system. See BS EN 12056:2000 for provision of access.

Email: info@wavin.co.uk

www.osma.co.uk

87

Design

Offsets

Offsets
Offsets are permitted in the dry portion of the stack and do not require venting. Offsets in the wet portion of a stack should ideally be avoided. Where this is unavoidable, use large radius bends. A secondary ventilation stack may be necessary to connect above and below the offset, to reduce siphonage threat to traps. The diameter of this ventilation stack pipework is typically half that of the discharge stack. (see Fig. 8)
4S190 Discharge stack Ventilating stack to atmosphere (or connected to dry portion of stack).

Fig. 8 Ventilation stack to atmosphere

4S163

4S319

4S190

88

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Connections to Drainage

Connections to Drainage
OSMA systems include couplers, connectors and adaptors to enable direct connection of OSMA Above and Below Ground Drainage Pipes, and to other systems made of PVC-U, cast iron and clay.

Connections to other materials


OSMA Soil connections to non-plastic drainage materials include:
l

To Clay To clay drain socket via Connector 4S107 To thinwall clay drain pipe spigot via Adaptor 4D129 To Cast Iron To CIay drain socket via Connector 4S107 To CI soil socket via Connector 4S106 OR Connector 4S206 To CI soil spigot via Connector 4S134 and Gasket 4S119

Connections to PVC-U
110mm OSMA Soil Pipe connections to PVC-U drainage pipes are straightforward using ring seal/push-fit Jointing and OSMA Below Ground Drainage fittings.
l l

Via Bend 4D581

Fig. 9 PVC-U drain socket (via 4D581)


OSMA Soil Pipe

For illustrations and detailed guidance on installation and connection procedures see
OSMA Below Ground Drainage Bend 4D581

page 107.

Via Coupler 4D205

Fig. 10 PVC-U drain spigot (via 4D205)

OSMA Soil Pipe

OSMA Coupler 4D205

PVC-U drain to BS EN 1401

Email: info@wavin.co.uk

www.osma.co.uk

89

Design

Connections to Drainage

Connections to Drainage continued Waste to drain connections


Waste pipes can be connected to below ground drainage by using Boss Socket Adaptors. For typical arrangements see Figs. 11-13. Fig. 11 Typical waste connection to Sealed Hopper
Waste pipe 4D563 Waste pipe Floor level 4D507 4D296/297 Ground level Ground level 2S398/399/402

Fig. 12 Typical internal waste pipe


connection to drain

4D205 2S398/399/402

4D500

4D561 Haunching

Fig. 13 Typical waste pipe connection to Bottle Gully

5V812 5A830

40mm [1] Waste pipe

4D399 4D296

4D900 4D163 4D561

90

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Connections to Waste

Connections to Waste Bossed fittings


Waste discharge pipework can be connected to the soil stack via a comprehensive range of Bossed Pipes and Bossed Branches, including:
l WC Bath SVP Basin

Fig. 15 Typical bathroom layout


4V816

Single Bossed Pipes with one open boss socket Bossed Pipes with one open boss socket and three closed boss sockets Bossed Branches with up to five closed boss sockets (see Fig. 14)
5C161

4C161

4A830

Discharge pipework feeding into the stack must be carefully designed to ensure safe flow and prevent cross flow. See Prevention of cross flow opposite Fig. 14 Alternative Bossed Branches
Bath Basin

WC NOTE: Refer to page 110 for installation details.

4S58

4S58

4S/6S589

4S588

4S772

Boss sockets
Closed boss sockets may be opened using a standard 50mm hole cutter. Boss Socket Adaptors are available with either push-fit sockets or solvent weld sockets:
l

Connections at floor level


The OsmaLink Soil Manifold 4S595 provides a simple method for connection of multiple waste pipes at floor level. The system is particularly suitable for use in flats and other multi-storey developments (see Fig. 16). With a right-angled back and compact, unobtrusive design, the OsmaLink Soil Manifold fits neatly in any corner and permits simple push-fit waste connection via standard Adaptors 2S356/355/354. Its integral socket allows push-fit connection of a branch or soil pipe. For installation details see page 111.

Fig. 16 OsmaLink Soil Manifold system

Push-fit: to enable connection to Polypropylene pipe manufactured to BS EN 1451-1, and copper waste pipes manufactured to BS 659 or BS 2871 Solvent weld: to enable connection to ABS pipe manufactured to BS EN 1455-1 and PVC-C pipe manufactured to BS EN 1566-1

4S595

2S356

2S355

All horizontal Boss Socket Adaptors have an in-built fall of 2 and a locating key at the top to ensure correct orientation.

2S354

Email: info@wavin.co.uk

www.osma.co.uk

91

Design

Connections to Waste

6 Boss Manifold

Connections to Waste continued Connections at floor level (continued)


The 6 Boss Soil Manifold - 4S597 is a compact fitting designed for easier installation where space is restricted. It is particularly suitable for multi-occupancy residential buildings.
l

Fig. 17 6 Boss Soil Manifold - 4S597

Horizontal waste connections: no upstanding bends required Compact 163mm square shaped body sits easily in 200mm drilled or formed hole Works equally well in corner or central locations 6 boss connection points increasing the options for joining separate waste runs Low-level horizontal waste connection (allows plumber flexibility to achieve 132mm from centre line of horizontal branch inlet to invert of 50mm waste boss) Dual 40mm/50mm solvent weld connection Easy to drill waste connections ample clearance from inner fitting section
203mm 50mm Push-Fit 40mm OsmaWeld

Fig 18 Typical Connections to Manifold

220mm

5Z.104 or 5Z.124 Double Socket

94mm

l l

Reduced requirement for bends No special adaptors needed


2M.104 Double Socket

4S.597

2Z.124 Expansion Socket

Fig. 19 4S597 - Typical Bathroom Installation

Screed Concrete

92

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Connections to Waste

Connections to Waste continued Connections after construction


Strap Bosses offer a low cost means of connecting waste pipes from basins, baths, bidets and showers to soil discharge pipework after construction. However, Strap Bosses are not recommended for use where high temperature discharges are likely (e.g. from kitchen sink wastes). For installation details see page 110. Permitted connections Bossed Branches have a maximum of five socket positions. Two waste pipes may be connected to one side, or one waste pipe may be connected to each side, provided both connections are at the same level (see Fig. 20). Single connections are also possible at the side and rear of the Branch. Connections NOT permitted Offset connections to each side of the Branch are NOT permitted (see Fig. 21). Fig. 21 Connections NOT permitted Fig. 20 Permitted connections

Prevention of cross flow


(see Fig. 22) Opposing connections to the stack are permitted provided that they are made:
l l

At the same centre line On or outside the edge of the connection zone created by any branch connection

See BS EN 12056:2000 for the prevention of cross flow.

Fig. 22 Prevention of cross flow


a) No connection zone for large branch
82, 110 or 160mm diameter branch. 32, 40 or 50mm diameter branch.

b) No connection zone for small branch

200mm regardless of stack diameter.

A (see table)

D Plan View Plan View 90

90

Stack Diameter D 82mm 90 90 110mm 160mm No connection permissible in shaded area. No connection permissible in shaded area.

Height of Zone A 90mm 110mm 250mm

Email: info@wavin.co.uk

www.osma.co.uk

93

Design

Connections to WC's

Connections to WCs WCs manufactured to BS 5503


OSMA Soil systems includes a wide range of white WC Connectors and bends for direct connection to WCs manufactured to BS 5503. PVC-U 110mm Fittings Available in 2, 14 and 90 angles, each fitting has:
l 190mm 94mm Low level 4S761 4S790 4S792

Fig. 24 Connection to ground floor WC

Fig. 25 Alternative connections to WCs

Integral EPDM gasket for push-fit connection to the WC outlet (see Fig. 24) Plain end (spigot) or solvent socket for connection to soil pipe/drain

For extension of a connector to overcome varying distances between WC spigot outlet and soil pipe/drain, S/S Long Tail Bend 4S790 may be added and cut to length. NOT to be used as WC Connector alone (see Fig. 25). 90 Connectors with access are also available for ground floor installations. Easy-Fit Pan Connectors 3 and 4 Available in straight, offset, 14 and 90 configurations, each fitting has:
l 94mm PVC-U drain

4S772

190mm Close coupled

WCs back-to-back
OSMA Corner Branch 87 4S291/491 enables connection of back-to-back WCs to drain (see Figs. 26/27). Fig. 26 Back-to-back WC installation

Integral EPDM gasket for push-fit connection to the WC outlet Integral EPDM seal for push-fit into 110mm plastic pipe, or 102mm cast iron pipe to BS 416 (see Fig. 23)

Fig. 23 Easy-Fit Pan Connector


Injection moulded body is strong and attractive Integral EPDM gasket is secured in its housing

4S291

4S163

Fig. 27 Alternative back-to-back WC installation


Flexible, long-life EPDM seal Corrosion resistant 4S291 4S161

WCs manufactured to BS 1213


Connectors and bends are available for straight connection direct to WC outlets (manufactured to BS 1213) when fitted with WC Gaskets 4S121 (for 4-4 WC spigot) or 4S120 (for 4-4 WC spigot).
4S772

94

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Connections to WC's

Connections to WCs continued WC connections direct to drainage


WCs may be connected direct to a drain. Venting will not be required provided that the distance from the crown of the trap to the invert of the drain does not exceed 1.5m (see Fig. 24). Fig. 28 Typical stub stack arrangement

Stub stacks
Designed as a 110mm discharge stack with access fitting cap on top. Connects various appliances to the drain or discharge stack, providing the total loading does not exceed 5 litres/sec. The distance from the invert level of the drain or discharge pipe to the topmost waste connection should not exceed 2.5m. The distance from invert level to centre line of the WC should not exceed 1.5m (see Fig. 28)
4S190 3S/4S/6S292 190mm

WC 4C263

4C163

Basin

Email: info@wavin.co.uk

www.osma.co.uk

95

Design

Connections to WC's

WC Manifolds Connecting multiple WCs


OSMA Manifold Branches can be used to connect multiple WC outlets to a common soil discharge float leading to the soil and vent pipe (SVP). Up to 8 WCs (to BS 5503) can be connected, depending upon gradient. The Manifold Branches are designed to be placed between the WC outlet and the wall behind it. As WC designs vary, this space should be checked to ensure there is sufficient room for manifold installation. Eleven Manifold Branches include: COMPONENTS
l

Planning component needs


Use the following procedure, in conjunction with the Graduated Scales Diagram (see Fig. 31), to determine which Manifold Branches are required: PROCEDURE 1. Draw 1:50 scale plan of proposed WC positions 2. Establish Left- or Right-hand orientation. Facing the WCs: If the SVP will be at the Left end, use Section A of the Scales If the SVP will be at the Right end, use Section B of the Scales

3. Select the Scale for the required gradient of the float run 4. Align arrowhead with first WC (furthest from SVP) 5. Provided all WCs fall within the Scale, proceed to Step 6. If not, select a shallower gradient and return to Step 4 6. Note each part number where the centre line of the WC outlet concerned falls within a section NOTE: If the centre line of the WC outlet falls between two sections, either Manifold Branch is suitable. In some cases, with shallow gradients and close-set WCs, the same Manifold Branch will be appropriate (see example illustrated).

4S602 to 4S606: Five left-hand angled versions 4S612 to 4S616: Five right-hand angled versions 4S601: One straight Branch Fig. 29 Left hand float for 8 WCs

4S292

The angled Branches are graduated from 8 to 38 in 7 increments. Each Branch, including the straight Branch, incorporates a WC Connector, with integral gasket, providing a minimum 2 deflection all round. The gradient will be between 0.5 and 5 (9 to 90mm per metre). The maximum available fall from the first WC (furthest from the SVP) to the last WC (nearest to the SVP) is 88mm (see Fig. 29).
4S195 4S606 4S605 110mm pipe 4S604 4S604 4S083 4S603
Flo

4S601 4S602 4S602


or lev el

Fig. 30 Typical layout of double manifold float

860 4S612

860

860 4S612

860 4S612 4S613

860

860 4S613

860 4S614 4S614

1050

96

Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design
l

To SVP 4S601 1.1m max Gradient = 2.5 (44mm/m) 4S601

4S606

4S605

4S604

4S603

4S602

To SVP

4S 606

4S 605

4S 604

4S 603

4S 602

Email: info@wavin.co.uk

WC Manifolds continued

1.8m max

Gradient = 1.5 (26mm/m)

To SVP Gradient = 1 (18mm/m)

4S606

4S605

4S604

4S603

4S602

4S 601

Connections to WC's

2.7m max

Fig. 31 Graduated Scales. NOTE must be used at 100% scale

To SVP Gradient = 0.5 (9mm/m)

4S606

4S605

4S604

4S603

4S602

4S601

5.4m max

A B

4S601 1.8m max

4S612 4S601

4S613

4S614

4S615

4S616

To SVP

4S 612

4S 613

4S 614

4S 615 Gradient = 2.5 (44mm/m)

4S 616

To SVP 1.1m max

www.osma.co.uk
4S613 Gradient = 1 (18mm/m) 4S614 4S615 4S616 To SVP 2.7m max 4S613 4S614 Gradient = 0.5 (9mm/m) 4S615

Gradient = 1.5 (26mm/m)

4S 601

4S612

Graduated Scales drawn 1:50

4S601

4S612

4S616

To SVP 5.4m max

97

Design

Ventilation

Ventilation General principles


Discharge pipework must be vented to prevent self-siphonage or induced siphonage, and to protect traps. Use of a separate ventilation stack to atmosphere is generally not required unless a sharp offset in the stack cannot be avoided (see also page 88). Branch pipes Separate ventilation of branch pipes is required only if the length and slope of the branch exceeds the dimensions set out in BS EN 12056:2000 or Part H of the Building Regulations (England & Wales), Part M (Scotland).

Air Admittance Valves


In many cases, and subject to certain design considerations, OSMA Air Admittance Valves (AAVs) may be installed as an alternative to traditional venting techniques. These reduce the number of ventilating pipes required to penetrate the roof in multi-installations, without affecting the performance of the drainage system. AAV description and operation OSMA AAVs include a diaphragm which, in the closed position, seals the unit and prevents foul air from escaping. Whenever internal pressure drops, the higher pressure external air opens the diaphragm to admit air and equalise the internal/external air pressure (see Fig. 32).

Soil stack ventilation


OSMA A1 Rated 110mm Air Admittance Valve 4S304 is designed for venting of:
l l

110mm soil stacks up to 10 storeys 110mm stub stacks

The 110mm AAV may be used on runs serving a row of 10 dwellings, provided the vent stack closest to the main sewer is vented traditionally to atmosphere. See also Drain Ventilation overleaf. When used to vent a soil stack, 110mm Air Admittance Valve 4S304 should be located:
l l

Within a building, fitted vertically Preferably in a non-habited space (duct or roof-space) Where there is no risk of freezing Where it is accessible but not at risk of interference by vandals Fitted 200mm above the highest branch

l l

Fig. 32 Valve operation

For full installation details see page 112. NOTE: This should not be the only vent to a
All plastic construction cannot rust or corrode

drainage system discharging to a septic tank or intercepting trap. OSMA A2 rated 110mm Air Admittance Valve 4S306 is designed for venting of:

Slimline shape fits easily into pipe ducts

Automatic valve action OPENS to admit fresh air when negative pressure occurs When pressure equalises, valve CLOSES tight: preventing escape of foul air Insect screen prevents ingress of insects or vermin

l l

110mm soil stacks up to 3 storeys 110mm stub stacks

The 110mm AAV may be used on runs serving a row of 10 dwellings, provided the vent stack closest to the main sewer is vented traditionally to atmosphere. See also Drain Ventilation overleaf. When used to vent a soil stack, 110mm Air Admittance Valve 4S306 should be located:
l

Push-fit rubber connector into open top of 110mm stack no solvent welding needed

Within a building, fitted vertically Preferably in a non-habited space (duct or roof-space) 150mm above the insulation in attic installations Where there is no risk of freezing Where it is accessible but not at risk of interference by vandals Installed above spillover level of highest appliance

Also polystyrene cap prevents freezing

l CLOSED OPEN

l l

NOTE: This should not be the only vent to a drainage system discharging to a septic tank nor intercepting trap. 98 Customer Services: 0844 856 5153 Technical Advice: 0844 856 5165 Technical Fax: 0844 856 5166

Design

Ventilation

Ventilation continued Stub stacks


When used to vent a stub stack, 110mm Air Admittance Valve 4S304 can be located 200mm above the highest branch. The Air Admittance Valve 4S306 must be installed above spillover level of highest appliance. (see Fig. 33).
4S306

Fig. 33 Vented stub stack

Waste ventilation
40mm Air Admittance Valve 4S303 is designed for venting of 32, 40 or 50mm waste pipework where the pipe run exceeds the recommended maximum distance from the trap to the stack, i.e.: 3m for 40mm pipe 4m for 50mm pipe The 40mm Air Admittance Valve 4S303 is suitable for use on single or combined waste systems. See page 112 for full installation details.

Basin

WC

Drain ventilation
110mm Air Admittance Valve 4S304 may also be used for drain ventilation. Typical arrangements for access and provision of drain ventilation for different dwelling types are shown in Fig. 34.

Fig. 34 Examples of provisions for drain ventilation


NOTE: Access arrangements shown are indicative only and may be varied to suit particular system layouts. A A A

A G A

A G G A

A G S A A

C A A A

S A A

Up to 4 dwellings fitted with OSMA 110 Air Admittance Valves

Single multi-storey building with OSMA 110 Air Admittance Valves and a maximum of two stacks 11th C G A 10th G A S 9th C G A 8th

More than one multi-storey building with OSMA 110 Air Admittance Valves on the same drain 3rd A 2nd S 1st C A G A A

20th C G A

13th

12th G A S

G A A

Head of drain

Row of 20 dwellings with OSMA 110 Air Admittance Valves on the same drain C - Conventional vent stack G - Gully S - OSMA 110 Air Admittance Valves A - Access

Email: info@wavin.co.uk

www.osma.co.uk

99

Design

Ventilation

Ventilation continued Ventilating roof screeds


Moisture in roof screeds may be caused by:
l l

Extract systems
Certain buildings require regulated airflows for use with ventilation and extraction systems (e.g. blocks of flats, hotels, student accommodation). The OSMA Extract Valve 4S709 (see Fig. 36) is solvent welded direct onto 110mm pipe to provide airflow that can be:
l l

Ventilation in radon gas areas


Certain areas of the UK (including Cornwall, parts of Somerset, Northamptonshire and Derbyshire) are known to be susceptible to radon gas contamination. Protective measures are explicitly required by Building Regulations Approved Document C2 when new building is proposed in areas where this possibility exists. Specific guidance is available:
l

Rainwater during drying/curing period Condensation from within the building, resulting in moisture vapour pressure build-up beneath the waterproofing

This could lead to:


l

Distortion, blistering and deterioration of mastic asphalt and mineral felt-covered roofs Reduced thermal insulation Staining of ceilings immediately below roof level (see Fig. 32)

Adjusted to the required rate Locked against unauthorised interference

l l

The Extract Valve has a polypropylene msnap cover over a PVC-U body. It contains no metallic components and so is non-corrosive in steamy and damp atmospheres. For full installation details, see page 118.

In Report Number BR211 Radon: guidance on protective measures for new dwellings published by the Building Research Establishment, or By telephoning the BRE Radon Hotline on 01923 664707

The OSMA Breather Vent 4S700 installed at 6 metre centres will allow this potentially damaging moisture-laden vapour to escape. For full Breather Vent installation details, see page 117.

All OSMA Soil & Waste pipework is suitable Fig. 35 OSMA Breather Vent for use in radon ventilation systems, but solvent weld joints are advisable.

Fig. 36 Extract Valve

100 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Fire Stopping

Fire Stopping Fire Stop Seals


OSMA Fire Stop Seals prevent the spread of fire, smoke and hot gases through plastic pipes that penetrate fire compartment floors and walls. The Seals consist of two half shells of metal which are clipped around the pipe and anchored to the structure. The metal shell contains an intumescent material which reacts under intense heat. Fire Stop Seals can be installed horizontally or vertically and provide an economic alternative to constructing fire resistant ducts. Seals are available for four pipe sizes: FITTINGS
l l l l l

Applications
OSMA Fire Stop Seals are suitable for maintaining the fire resistance of:
l

Masonry walls and concrete floors which are penetrated by plastic pipework forming part of a drainage or ventilation system Timber floor constructions with ceiling lining which has at least one hour fire resistance rating

OSMA Fire Stop Seals can be fixed before or after the installation of the pipes and operate horizontally or vertically. For horizontal pipework where there is a fire risk from BOTH sides of the wall, the unit should be installed within the thickness of the wall or, if this is not possible, one unit should be fitted to each side of the wall (see Fig. 37). OSMA Fire Stop Seals are suitable for all types of new or refurbished buildings, especially residential flats, apartments, offices, hospitals, and schools. They must be carefully fitted strictly in accordance with instructions. For full installation details, see page 109.

2S001 for 50mm waste pipe 3S001 for 82mm soil pipe 4S001 for 110mm soil pipe 6S001 for 160mm soil pipe

Testing
OSMA Fire Stop Seals have been tested to BS 476: Part 20 at the Warrington Fire Research Centre. All sizes met insulation and integrity criteria for up to 4 hours.

Fig. 37 Fixing positions for Fire Stop Seals in concrete floor/masonry wall
Pipe

Fire Stop Seal

Fire S top Seal Fire Stop Seal Concrete/wall

Email: info@wavin.co.uk

www.osma.co.uk

101

Design

Materials

Materials: Properties and Performance Heat resistance


Pipes and fittings manufactured from PVC-U or ABS: OSMA Soil systems and ABS Solvent Weld Waste system: OsmaWeld Suitable for use with intermittent discharges of water up to 90C. Pipes and fittings manufactured from PVC-C or Polypropylene: PVC-C Solvent Weld Waste system, PP Push-Fit Waste systems (to BS EN 1451-1 and BS EN 1566-1) and V-Joint Traps Suitable for use with intermittent discharges of water up to 100C. PVC-U and ABS overflow pipes and fittings: Solvent Weld Overflow system: Must not be used where hot water discharges are likely to occur. Polypropylene overflow pipes and fittings: PP Push-Fit Overflow system: May be used where intermittent hot water discharges are likely to occur. However, they must not be used with combination hot water cylinders and feed tanks.

Painting
OSMA Soil, Waste and Overflow pipes and fittings are self-coloured and corrosion resistant. They may, however, be painted with normal household paints if an alternative colour is required. Oil-based gloss paint is the most suitable for this purpose. For best results, slightly abrade the surface with sandpaper and clean thoroughly before painting.

Ultra violet light


PVC-U and PVC-C pipework has superior resistance to the effects of UV light and, although it may fade slightly after many years of exposure to strong sunlight, its integrity is unaffected. It is recommended that externally installed ABS and PP pipework be painted with an oil-based gloss as a protective coating against long exposure to sunlight.

Radon gas resistance Timber preservatives


If soil or waste pipes and fittings are to be installed externally and fixed to timber fascias or boards treated with timber preservatives, the preservatives must first be allowed to dry out prior to fitting. Refer to manufacturers recommendations. Soil pipes and fittings are unaffected by radon gas when used as part of a ventilation system designed specifically for radon gas extraction. For connections made within a building, the use of solvent weld joints is advisable. For further information on radon gas, contact the BRE Radon Hotline on 01923 664707.

Biological attack
Normal pollutants in the atmosphere will not affect Soil, Waste or Overflow systems. They are also unaffected by fungi, moss, lichen, moulds or bacteria.

Physical attack
If pipework is installed internally or externally in areas likely to suffer attacks by vandals, the suitability of the material should be questioned. In such a situation, Solvent Weld systems are less likely to be dismantled than Ring-Seal or Push-Fit systems. However, unlike cast iron or copper systems, plastic has no scrap value and is therefore less likely to be targeted.

Chemical resistance
OSMA Soil, Waste and Trap systems are unaffected by normal domestic effluent, detergents, cleaning fluids and a wide range of chemicals. Chemical effluent containing solvents should not be disposed of through PVC-U and ABS Waste systems. For commercial and industrial applications, consult BSCP 312: Part 1: 1973 Code of Practice for plastic pipework. This provides comprehensive information on chemical resistance to plastic pipework.

102 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design

Handling & Storage

Handling and Storage Handling


Care should be taken when handling pipe and fittings. Excessive scratching or scoring harms the appearance and can also affect the joint sealing. Take extra care when handling pipe and fittings in wintry conditions. Cold weather reduces the impact strength of plastics. Use nylon belt slings, or forklifts with smooth forks, for mechanical unloading of block bundles. Metal slings, hooks or chains must not come into contact with pipes (see Fig. 38). Load and unload loose pipe by hand. Avoid using skids. When loose pipes have been transported one inside the other, always remove the inner pipe first. Fig. 38 Unloading of block bundles

Storage
Always store pipe on a reasonably flat surface free from sharp projections.

Fittings
Store fittings supplied in plastic bags away from direct sunlight. If this is not possible, open bags to prevent a build-up of temperature. Fittings in cardboard packaging (e.g. Fire Stop Seals and Air Admittance Valves) should be stored under cover until required. Store degreasing cleaners, silicone lubricant, solvent cement and fillers in a cool place away from any heat source and out of direct sunlight.

Block bundles
Block bundles can be stored up to 3m high without extra side supports or bearers. Block bundles will remain free-standing when cut. Take care when releasing bundles as the straps are under considerable tension and may flail when cut.

Loose pipes
Loose pipe requires side supports at least every 2m. These supports should consist of battens at least 75mm wide. Ideally, support loose gutter or pipe uniformly throughout its entire length. If this is not possible, place timber supports at least 75mm wide at 1m maximum centres beneath the pipe (see Fig. 40) Stack different size pipe separately, or, if the bottom. Maximum stack size: 7 layers or 2m high (see Fig. 39). Stack Socketed Pipe with sockets protruding and placed at alternate ends to ensure pipe is evenly supported. not possible, stack with larger diameters at

Safety
The relevant regulations detailed in the Health and Safety at Work Act 1974 must be adhered to on site. Fig. 39 Storage of loose pipe on the ground

2m or 7 layers max.

2m

Fig. 40 Storage of loose pipe on bearers

1m spacing maximum

75mm bearing width

Email: info@wavin.co.uk

www.osma.co.uk

103

Installation

Pipe Cutting & Jointing

Pipe Cutting and Jointing Pipe cutting


Pipe may be cut on site using a fine-toothed hand saw. PROCEDURE 1. Cut pipe cleanly at right angles to its axis (see Fig. 41) 2. De-burr the cut end with a scraper if the cut end is to be inserted into a ring-seal or push-fit joint 3. Chamfer the spigot end: this is essential to ensure that the sealing ring is not displaced during insertion Fig. 41 Pipe preparation
1. Cut pipe square

Ring-seal/push-fit jointing
PROCEDURE 1. Ensure any pipe cut on site is also chamfered 2. Check that the sealing ring is properly seated in its housing in the socket of the fitting 3. Ensure all components to be joined are dry, clean and free from grit or dust. Note any deep scratches on the pipe or fitting spigot as these may prevent the sealing ring from forming a water tight seal 4. Lubricate evenly around the pipe or fitting spigot end with Silicone Lubricant 4S391. Do NOT lubricate inside the socket. Do NOT use washing up liquid as a lubricant. If using 400ml can 4S392, spray the lubricant onto the spigot and not the ring seal. The spigot can then be inserted into the socket 5. Correctly align the components to be joined

6. Push the pipe or fitting spigot fully into the socket. Mark the pipe or fitting spigot at the socket face and then withdraw it by a minimum of 12mm to allow for thermal expansion (see Fig. 42) 7. Make a subsequent check to ensure that the expansion gap is not lost during further installation work Fig. 42 Ring-seal joint
Depth of entry mark

Ring-seal

3S/4S/6S124 Socket

Solvent cement

Table 21: Lubricant Usage Guide (approx.) For ring-seal/push-fit joints Description Silicone Lubricant 50g tube Part No. 4S391 32 44 Nominal Pipe Sizes (mm) No. of Joints 40 50 82 110 37 20 16 9 160 4

2. Chamfer and deburr spigot end

104 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Pipe Cutting & Jointing

Pipe Cutting and Jointing continued Solvent weld jointing


PROCEDURE 1. Before using any solvent based cleaners or cement: Read instructions on the can Ensure there is sufficient ventilation 2. Make sure pipe or fitting spigot and solvent weld socket are dry, clean and free from grit or dust 3. Clean surfaces of spigot and socket with Degreasing Cleaner N.1 4S379/ 380. Apply liberally using a clean non-synthetic rag or absorbent paper 4. Apply one coat Solvent Cement N.2 4S383/384/385. Apply an even coat to both surfaces using the applicator provided or a paint brush. Stroke the cement ALONG and not around the surfaces 5. Immediately insert pipe or fitting spigot fully into the socket (see Fig. 43). Each solvent weld joint MUST be completed within 1 minutes
3S/4S/6S124 Socket Solvent cement

6. Hold for 20-30 seconds. Remove any surplus cement from the mouth of the socket 7. The joint may be handled after 10 minutes and commissioned after 24 hours NOTE: Complete soil stacks can be prefabricated using the OSMA Solvent Weld system. This may be useful where identical designs are required for multiple projects. Fig.43 Solvent cement joint

Safety
When making solvent weld joints it is essential to observe normal safety rules for handling solvent:
l

Never smoke or bring naked flames near the area of work Work in a well ventilated area to avoid inhaling fumes Close the solvent container after use and store in a cool area Do not allow solvents or cleaners to come into contact with skin

Refer to COSHH Regulations (Control of Substances Hazardous to Health) where applicable.

Table 22: Cleaner/Solvent Cement Usage Guide (approx.) For solvent weld joints Description Degreasing Cleaner No.1 125ml can Degreasing Cleaner No.1 250ml can Solvent Cement No.2 125ml can Solvent Cement No.2 250ml can Solvent Cement No.2 500ml tin Part No. 4S379 4S380 4S383 4S384 4S385 19 120 240 90 180 360 Nominal Pipe Sizes (mm) No. of Joints 32 40 50 82 110 70 45 33 25 16 140 45 90 180 90 30 60 120 66 20 40 80 50 8 16 32 32 5 11 22 160 10 20 3 6 12

Email: info@wavin.co.uk

www.osma.co.uk

105

Installation

Pipe Support & Centres

Pipe Support and Offsets Pipe support centres


Pipes should be supported at the following maximum centres
Table 23: Maximum Pipe Support Centres Pipe Size (mm) 19 32 40 50 82 110 160 Centres (m) Vertical Horizontal 0.5 0.5 1.2 0.5 1.2 0.5 1.2 0.6 2 1 2 1 2 1.2

8. Fix the Braces to the ceiling: one at the side of, and one behind, the socket using bolts appropriate for the ceiling material NOTE: Not suitable for use in damp, inaccessable voids Fig. 44 Suspended Bracketing
(socket support)
Adjustable Brace Threaded Bracket

NOTE: Not suitable for use in damp, inaccessable voids Fig. 45 Suspended Bracketing
(intermediate pipe support)
Threaded Bracket

Threaded Rod Threaded Rod Bracket Plate

Bracket Plate

Suspended Brackets
The OSMA Suspended Bracketing system provides horizontal support for socket and intermediate pipework for 110mm and 160mm Soil installations. All fittings should be bracketed and braced using 4S085/6S085. Ensure that pipe is supported at recomended centres Socket Support 4S085/6S085 COMPONENTS
l l l l l

Pipe/Socket Bracket

Pipe/Socket Bracket

Offsets
The minimum offsets that can be achieved in each size (with part numbers) are as set out below:
Table 24: Minimum Achievable Offsets Pipe Size (mm) 82 110 160 Part No. 3S444 4S444 6S435 Minimum Offset 115 155 233

Threaded Rod Threaded Bracket Bracket Plate Adjustable Braces (2) Pipe/Socket Bracket

Intermediate Pipe Support 4S086/6S086 COMPONENTS


l l l l

Threaded Rod Threaded Bracket Bracket Plate Pipe/Socket Bracket

PROCEDURE 1. Fix the Threaded Bracket to the ceiling using bolts appropriate for the ceiling material 2. Screw the Threaded Rod into the Threaded Bracket 3. Fix the Braces and Bracket Plate onto the Threaded Rod using the two nuts and washers provided 4. Adjust the height of the Bracket Plate to the required fall, and cut the rod below the lower nut 5. Adjust the length of the Braces using the nuts on the Braces themselves 6. Fit the Pipe/Socket Bracket over the socket to be supported, directly behind the socket shoulder 7. Fix the Pipe/Socket Bracket to Bracket Plate using the two bolts provided

PROCEDURE 1. Fix the Threaded Bracket to the ceiling using bolts appropriate for the ceiling material 2. Screw the Threaded Rod into the Threaded Bracket 3. Fix the Braces and Bracket Plate onto the Threaded Rod using the two nuts and washers provided 4. Adjust the height of the Bracket Plate to the required fall, and cut the rod below the lower nut 5. Fit the Pipe/Socket Bracket over the pipe to be supported 6. Fix the Pipe/Socket Bracket to Bracket Plate using the two bolts provided

Alternatively, for 110mm installations, use an adjustable bend (push-fit): 4S173 for 0 to 30 angles 4S179 for 0 to 90 angles

106 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Connections to Below Ground Drainage

Connections to Below Ground Drainage Connections to PVC-U


110mm OSMA Soil Pipe connections to PVC-U are straightforward using ring-seal/ push-fit jointing and OSMA Below Ground Drainage fittings (page 104). Via OsmaDrain Bend 4D581 Fig.46 PVC-U drain socket
OSMA Soil Pipe OSMA Soil Pipe

To thin-wall clay drain pipe spigot via OsmaDrain Adaptor 4D129 PROCEDURE Use ring-seal/push-fit jointing method (page 104) Fig.49 Thin-wall drain spigot

Fig.51 Cast iron soil socket


OSMA Soil Pipe Connector 4S106

Iron drain

Adaptor 4D129

To cast iron soil socket via OsmaSoil Connector 4S206 PROCEDURE 1. Place Connector inside cast iron socket 2. Lubricate plain end of pipe

Bend 4D581

Thinwall clay drain pipe

To cast iron drain socket via OsmaSoil Connector 4S107 Via OsmaDrain Coupler 4D205 Fig.47 PVC-U drain spigot
OSMA Soil Pipe

3. Push in soil pipe spigot Fig.52 Cast iron soil socket


OSMA Soil Pipe

PROCEDURE 1. Apply a bead of non-setting mastic to the face of the Connector and position centrally in the cast iron drain socket 2. Caulk the joint with gaskin followed by lead wool, (NOT hot lead) 3. Finish with 2:1 sand cement mortar

Connector 4S206

Iron pipe

Coupler 4D205

PVC-U drain to BS EN 1401

Fig.50 Cast iron drain socket


OSMA Soil Pipe Connector 4S107 Lead Wool or Sand/cement Caulking material Mastic bead Cast iron drain

To cast iron soil pipe spigot via OsmaSoil Connector 4S134 and Gasket 4S119 PROCEDURE 1. Place rubber gasket or seals over spigot of iron pipe to be positioned centrally within the Adaptor socket 2. Heat uniformly with blow torch or hot air gun, taking care not to scorch the Adaptor, until the socket shrinks over the seal and spigot Fig.53 Cast iron soil spigot
Iron pipe

Connections to Other Materials


To clay drain socket via OsmaSoil Connector 4S107 PROCEDURE 1. Apply a bead of non-setting mastic to the face of the Connector and position centrally in the clay drain socket 2. Caulk the joint with yarn 3. Finish with 2:1 sand cement mortar Fig.48 Clay drain socket
OSMA Soil Pipe Connector 4S107 Caulking material

To cast iron soil socket via OsmaSoil Connector 4S106 PROCEDURE 1. Apply a bead of non-setting mastic to the face of the Connector and position centrally in the cast iron drain socket 2. Caulk the joint with gaskin, followed by lead wool (NOT hot lead).

Sand/cement

Connector 4S134

Gasket 4S119

Clay drain

Mastic Bead

Email: info@wavin.co.uk

www.osma.co.uk

107

Installation

Access Saddle

WC Manifold Branches

Access Saddle
Where access to soil pipework is required without using a fitting with an integral access facility, the Access Saddle 4S275 may be used on 110mm pipe to BS 4514. COMPONENTS This comprises:
l l l l l l

PROCEDURE 1. Mark the position on the pipe where access is required 2. Cut a hole in the pipe EITHER With a pad saw using the template provided OR With a hole cutter 89mm in diameter and over 40mm depth 3. Deburr and clean the area around the hole, and the mating surfaces, with Degreasing Cleaner No.1 4S379/4S380 4. Apply Solvent Cement Filler 4S394 to the mating surfaces 5. Fix Saddle to the pipe over the hole NOTE: Application of solvent and fixing to pipe must be completed within 1 minutes 6. Clamp with the ring provided as steps illustrated (see Fig. 55) 7. The clamp may be removed after 10 minutes

Fig. 54 Access Saddle


Saddle Insert and seal Cap

Saddle Access Liner Access Cap Access Cap Gasket Clamp Ring Hole Template

Fig. 55 Installation of Access Saddle

(b)

(a)

(c)

WC Manifold Branches
OSMA WC Manifold Branches are designed to provide direct connections to BS 5503 washdown or siphonic WC pans in space between WC outlets and the wall. Eleven Manifold Branches are available:
l 4S601 4S602 4S083 4S603 110mm pipe 4S604 4S605 4S606 4S604
Flo

Fig. 56 Left hand float for 8 WCs


4S292

Five left-hand angled versions 4S602 to 4S606


4S602

Five right-hand angled versions 4S612 to 4S616 One straight Branch 4S601

or

lev

el

The Angled Branches are graduated from 8 to 38 in 71/2 increments. Each Branch, including the straight Branch, incorporates a WC Connector, with integral gasket, providing a minimum 21/2 deflection all round. Used together, they can connect up to 8 WCs depending on the gradient. BS EN 12056-2: 2000 permits a float gradient of 0.5 to 5 (9 to 90mm per metre). Maximum fall from the first WC (furthest from the soil and vent pipe) to the last WC (nearest the soil and vent pipe) is 88mm. See page 96-97 for guidance on planning component needs.

4S195

108 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Fire Stop Seals

Fire Stop Seals


OSMA Fire Stop Seals provide protection for plastic pipe penetrating fire compartment floors and walls. Seals are available for four pipe sizes: PROCEDURE Fixing with four brackets: 50mm Waste Pipe 2S001 82mm Soil Pipe 3S001 110mm Soil Pipe 4S001 Fixing through six holes in flange: 160mm Soil Pipe 6S001 IMPORTANT NOTE: Do NOT use plastic fixings. These are unsuitable Fig. 57 Plan view of fixing positions of brackets

Handling
OSMA Fire Stop Seals should be:
l

Stored in dry conditions and protected from flames or other sources of ignition prior to and during installation Fig. 58 Plan view of OSMA Fire Stop Seal under a timber floor Protected from physical damage during and after installation

Safety
OSMA Fire Stop Seals do not contain toxic chemicals and present no known hazards in use.

Preparation
The floor soffit or wall surface must be smooth. Make good any irregularities using a proprietary intumescent mastic.

Installation
PROCEDURE 1. Place the two halves of the Seal unit around the pipe and securely fasten the side clips (2S/3S/4S001) 2. Position the brackets. Where possible, these should be equally spaced around the circumference of the Seal unit 3. Secure the brackets to the floor or wall so that they fully cover the flange of the unit. When finally tightened, they should provide a firm hold on the flange NOTE: For installation to the underside of timber floors, the screws should be securely fixed to noggings and counter noggings
610mm

Email: info@wavin.co.uk

www.osma.co.uk

109

Installation

Connections to Waste

Soil Connections to Waste Installing Boss Socket Adaptors


To use unperforated boss socket positions on Bossed Pipes and Bossed Branches: PROCEDURE 1. Drill required unperforated boss socket position with 50mm hole cutter 2. Deburr and clean area around hole with Degreasing Cleaner No. 1 4S379/4S380 3. Apply Solvent Cement No.2 4S383/ 4S384/4S385 to both mating surfaces 4. Fit the appropriate Boss Socket Adaptor ensuring the top locating key fits into the corresponding key-way on the fitting
l

Permitted connections
Bossed Branches have maximum five waste socket positions. These may be utilised as follows:
l l

Installing Strap Bosses


COMPONENTS Strap Bosses 4S318, 3S319 and 4S319 provide an inexpensive method of connecting waste from basins, baths, bidets and showers fittings to 110mm soil stack pipework PROCEDURE 1. Mark the position on the stack where the boss is required 2. Drill a 56mm diameter hole 3. Deburr and clean the area around the hole with Degreasing Cleaner No. 1 4S379/4S380 and clean the mating surface of the Boss 4. Apply Solvent Cement Filler 4S394 to the mating surface of the Boss 5. Fit the Boss to the hole ensuring top is uppermost, and bolt together

Two waste pipes to one side One waste pipe each side on the same level Single connections at side and rear

Fig. 59 Permitted connections

Installing Short Boss Pipe 4S588


32, 40 and 50mm pipe may be connected via appropriate Boss Socket Adaptor as normal procedure discribed above (see Boss socket Adaptors above). Alternatively, 40mm pipe may be directly connected via a solvent weld socket: 1. Open spigot connection using 35mm hole cutter 2. Deburr and clean area around hole with Degreasing Cleaner No. 1 4S379/4S380 3. Solvent weld appropriate socket onto spigot tail of the bossed connection. For solvent weld jointing procedure, see page 105.
5-Boss Branch 4S195/395 5-Boss Branch 4S195/395

6. Allow 24 hours before completing Boss Socket Adaptor connection

Connections NOT permitted Offset socket connections are not permitted Fig. 60 Connections NOT permitted Fig. 62 Connection of Strap Bosses

56mm diameter

Connection of multiple wastes Fig. 61 Connection of multiple wastes

Fig. 63 Fitting Boss Socket Adaptor


Strap Boss 3S/4S319

5-Boss Branch 4S395

Boss Adaptor 2S398/9

110 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Connections to Waste

Manifold

Soil Connections to Waste continued Installing Soil Manifold


The OsmaLink Soil Manifold provides a simple method of making up to three waste pipe connections to the stack at floor level. No drilling, sawing or welding is necessary for installation. The sockets allow direct connection for 50mm pipe, and connection of 32mm and 40mm pipe via reducers to BS EN 1451-1, BS 5254, BS 5255 and copper wastes to BS 659 and BS 2871. Horizontal connections Make horizontal connections using the following bends/adaptors: For 50mm pipe use the All-Fit 90 Spigot Bend 2S356 For 40mm pipe use the All-Fit Reduction Bend 2S355 For 32mm pipe use All-Fit Reducer 2S354 with All-Fit Reduction Bend 2S355 Vertical connections Make vertical pipe drops into the OsmaLink Soil Manifold as follows: For 50mm pipe no reducer/adaptor required For 40mm pipe use synthetic rubber Reducer 2Z349 For 32mm pipe use synthetic rubber Reducer 2Z347 Locate Reducer in socket as follows: PROCEDURE 1. Lubricate the Reducer 2. Push into the required socket The OsmaLink Soil Manifold is supplied with one open socket. To use the other sockets, simply remove the socket plugs. The connections are push-fit. There is no need for solvent welding.
Waste pipe Waste pipe W.C. Branch Waste pipes OsmaLink Soil Manifold 4S595 Waste pipe First Floor Level SVP W.C. Branch

Fig. 64 Typical OsmaLink Soil Manifold installation (side view)

Fig. 65 Typical OsmaLink Soil Manifold installation (plan view)

6 Boss Soil Manifold 4S597


A compact manifold designed for easier installation where space is restricted. It is particularly suitable for multi-occupancy residential buildings. see page 92 for further details

OsmaLink Soil Manifold 4S595

Email: info@wavin.co.uk

www.osma.co.uk

111

Installation

AAV's

Air Admittance Valves OsmaVent 110


The OsmaVent 110mm Air Admittance Valve 4S304/4S306 (AAV 110) is designed for venting 110mm soil pipe stacks. It prevents siphonage and protects traps by allowing air into the discharge pipework without allowing foul air to escape. Soil Stack Ventilation See page 98 for details on ventilation. For connecting to 110mm pipe PROCEDURE 1. Cut the 110mm PVC-U pipe square to its axis 2. Clean and remove swarf 3. Push-fit the valve into the pipe end (no lubrication necessary) 4. To achieve the A1 rating -20C the 4S304 will require the top half of packaging to be fitted over it. 5. To achieve A2 rating 0C, the 4S306 does not require insulating when used in the loft For connecting to 82mm pipe PROCEDURE 1. Remove rubber connector from AAV 2. Solvent weld AAV onto short length of 82mm pipe 3. 82mm pipe should be connected to the soil stack via a ring-seal fitting to allow the AAV to be easily removed for access to drainage system Venting of stub stack If a stub stack access assembly, to which ground floor cloakroom appliances are commonly connected, is discharging into a non-vented nearby drain, it will require venting eg. via AAV. The OSMA 110mm Air Admittance Valve 4S304 may be used to vent a stub stack in the following circumstances: If the crown of the WC trap is more than 1.5m above the drain invert The topmost connection to the stack is more than 2m from the drain invert
Basin WC 110 Air Admittance Valve 4S306

Fig. 66 Vented stub stack

OsmaVent 40
Designed for venting waste systems when the length of waste pipe from trap to stack exceeds the following dimensions: 40mm pipe: 3m 50mm pipe: 4m The OsmaVent 40mm Air Admittance Valve 4S303 (AAV 40) prevents siphonage and protects traps by allowing air into discharge pipework without allowing foul air to escape. It is suitable for venting up to 5 wash basins. OsmaVent 40 push-fits onto 32 and 40mm (11) waste pipework to BS EN 1451-1, BS EN 1455-1 and BS EN 1566-1. It should be installed vertically and located in an accessible space. For connecting to 32mm pipe PROCEDURE 1. Install the valve directly onto the deburred pipe 2. In areas of extreme temperatures cover the installed valve with the insulation

For connecting to 40mm pipe PROCEDURE 1. Remove the connector from base of valve 2. Pull away the inner part of connector 3. Ensure the pipe is cut square and remove burrs. Push the connector approx. 50mm down the pipe 4. Place valve on top of pipe 5. Holding the valve onto the pipe push up the connector until secure over the valve 6. In areas of extreme temperatures cover the installed valve with the insulation Fig. 67 Installation of OsmaVent 40mm In areas of extreme temperatures

112 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Weatherproofing Soil Stack

Weatherproofing Soil Stack Installing Weathering Collar


For maintaining watertight seal between pipe and traditional flashing: FITTINGS Weathering Collar 82mm 3S300 110mm 4S300 160mm 6S300 PROCEDURE 1. Apply solvent weld to pipe immediately above flashing upstand using Solvent Cement Filler 4S394 2. Slide down into position with cone section over the flashing upstand to form a watershed
l

Installing Pipe Flashings


VariPitch Pipe Flashings are suitable for use on pitched or flat roofs, and with felt or asphalt finishes for 82mm or 110mm PVC-U pipe. FITTINGS
l

Pitched Roofs PROCEDURE 1. Secure vent pipe in position through roof 2. If necessary, lubricate pipe with silicone lubricant to enable flashing to slide into position 3. Fit flashing over stack pipe, and dress to suit roof tile profile 4. To aid rigidity in exposed locations, a welt may be formed on front and side edges of apron 5. Ensure back of apron is supported to prevent sagging between the rafters Flat Roofs: Felt PROCEDURE 1. Secure vent pipe in position through roof

For flat roofs: VariPitch Pipe Flashing 4S281 (400 x 400mm) For pitched roofs between 12 and 55: VariPitch Pipe Flashing 4S283 (450 x 450mm), VariPitch Pipe Flashing 4S285 (600 x 600mm)

Fig. 69 Installation of VariPitch flashings pitched

Fig. 68 Installation of Weathering Collar


Balloon Grating 3S/4S/6S302

2. If necessary, lubricate pipe with silicone lubricant to enable flashing to slide into position 3. Fit first layer of felt around the pipe 4. Fit flashing over stack pipe

Weathering Collar 3S/4S/6S300

5. Bed flashing in bitumen 6. Butt second layer of felt to the edge of the apron
Traditional flashing

Fig. 70 Installation of VariPitch flashings - flat

7. Fix third layer of felt in bitumen over the apron and around the cone of the flashing Flat Roofs: Asphalt PROCEDURE 1. Secure vent pipe in position through roof 2. If necessary, lubricate pipe with silicone lubricant to enable flashing to slide into position 3. Fit flashing over stack pipe 4. Apply asphalt over apron. Do not allow asphalt to come into contact with the unsupported cone of the flashing 5. For improved adhesion, turn back apron edge approximately 12mm before applying asphalt

Email: info@wavin.co.uk

www.osma.co.uk

113

Installation

Traps

Traps
OSMA Waste pipes will fit directly into the integral compression joint on OSMA V-Joint Traps and Compression Joint Traps.

All-Fit Conversion Bend


The 90 Conversion Bend 4A/5A830 converts a P trap outlet to a S trap outlet. To connect pipe: Simply lubricate the spigot end of the end and insert into the outlet socket of the trap.

Bath Trap and WasteFlow Unit 5V859


Used with the Bath Trap, the WasteFlow Unit provides a bath overflow as well as a neat and convenient means of disposing of overflow from both cold water storage and WC cisterns. Use of the Wasteflow Trap eliminates the need for external overflow pipes and possible damage to walls through dripping overflows. Water overflowing from the storage or WC cistern enters the bath through the overflow grating. This creates a nuisance value and indicates that the ball valve requires attention. The design of the grating ensures that any water that discharges drips clear of the sloping end of the bath and is more noticeable. This water may then be let out of the bath via the waste outlet or, in the event of the bath filling, back through the bath overflow proper, finally passing through the waste trap. A weir device is incorporated into the manifold unit as a safeguard against water flowing back along the overflow pipe. If the bath fills with water, the overflow discharge will be prevented from entering the overflow pipe by the weir and pass safely down the flexible hose into the bath trap. Fig. 72 Operation of WasteFlow Unit supplied with Bath Trap 5V859
Overflow from cold water tank or cistern (or both) Weir Manifold outlet to bath

V-Joint Traps
V-Joint Traps have a three-part compression type outlet incorporating an internal sleeve. To connect pipe: PROCEDURE 1. Remove outlet nut, red outlet thrust washer and black wedge seal 2. Clean off any burrs or rough edges and chamfer the inside of the pipe (if necessary) 3. BS EN 1451-1, polypropylene pipe should be first warmed in hot water to enable it to be pushed over the internal sleeve and into the trap 4. Slide the nut and red washer over the pipe. Push the black seal onto the pipe with the thick end towards the red washer 5. Firmly push the pipe into the trap. Slide the washer and seal to the edge of the outlet 6. Hand tighten the nut, finishing with a quarter turn using a spanner or wrench NOTE: If the plastic pipe is undersized, or out of shape, the end of the pipe may need to be warmed in hot water

Washing Machine Traps


Four different traps are available for connection to outlets of washing machines and dishwashers:
l l l

P Half Trap 5V864 P Full Trap 5V868 Trap 5V870 with Standpipe and two brackets Adjustable P Trap 5V869

Care should be taken to observe appliance manufacturers installation instructions, particularly with regard to the height of the discharge hose and the incorporation of an air break or vent to atmosphere.

Making threaded connections


PROCEDURE 1. To help prevent capillary action, wrap PTFE tape around the male thread prior to screwing into the threaded socket or screwing on the threaded nut 2. Screw in hand tight plus a quarter turn. Do not over tighten, as damage may occur NOTE: Do NOT use linseed oil based jointing compounds with plastic components

Fig. 71 Connection to V-joint trap outlet


Black wedge seal

Making Bath Trap Overflow connections


Waste pipe Trap outlet Nut Thrust washer

PROCEDURE 1. Unscrew rose terminal and position in hole in bath 2. Fit rubber washer over threaded spigot on the outside of the bath. Screw into socket of overflow connections 3. Hand tighten and finish with a quarter turn with spanner or wrench
Overflow from bath to trap Manifold inlet

Overflow from cold water tank or cistern (or both) into bath

114 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Traps

Shower Gullies

Traps continued Connecting Bath Trap Overflow


Connect Bath Trap Overflow in normal manner: PROCEDURE 1. Unscrew rose terminal and position in hole in bath 2. Fit rubber washer over threaded spigot on the outside of the bath. Screw into socket of overflow connections 3. Hand tighten and finish with a quarter turn with spanner or wrench

Connecting Overflow Pipe


The WasteFlow Bath Trap has a 1 male BSPT inlet for connection of between two and four 21.5mm connections via WasteFlow Tees:

WasteFlow Tee 4-way 5V837


Allows:
l

Push-fit connection of up to four 21.5mm Push-Fit Overflow Pipes 1C074 Solvent weld connection of up to four Solvent Weld Overflow Pipes 1E074

WasteFlow Tee 2-way 5V836


Allows:
l

Push-fit connection of up to two 21.5mm Push-Fit Overflow Pipes 1C074 Solvent weld connection of up to two Solvent Weld Overflow Pipes 1E074

Shower Gullies Shower Gullies


The OSMA range includes shower gullies for installation in tiled and sheet floor finishes. Both models include pre-drilled countersunk screw holes to the flange for installation within a timber-joisted floor.

Shower Gully sheet floor


PROCEDURE 1. Cut hole in moisture resistant flooring board to take gully. Recess board so that top of drain flange is level with deck 2. Firmly secure drain body to deck via the pre-drilled screw holes to flange 3. Connect pipe using solvent weld joint 4. Lay the sheet flooring to manufacturers instructions. Dress over rim of gully and trim sheet to edge of clamping rim screw holes 5. Screw clamping ring firmly in position 6. Engage bell, ensuring O ring lodges beneath screw heads on the clamping ring

Pipe connection
Connect pipe to Shower Gully via a solvent weld joint. For jointing procedure, see page 105.

Shower Gully tiled floor


PROCEDURE 1. Cut hole in moisture resistant flooring board to take gully. Recess board so that top of drain flange is level with deck 2. Firmly secure drain body to deck via the pre-drilled crew holes to flange 3. Connect pipe using solvent weld joint 4. Apply waterproof membrane to manufacturers instructions. Dress over rim of gully and secure with clamping ring 5. Affix tiles with approved waterproof adhesive, ensuring the OSMA tile or stainless steel tile is square over the gully 6. Insert circular grate in pre-formed hole in tile

Email: info@wavin.co.uk

www.osma.co.uk

115

Installation

Overflows

Overflows Connection to tanks and cisterns


The OSMA PP Push-Fit Overflow system connects to tanks and cisterns via 90 Bent Tank Connector 1C139 (item supplied with two gaskets). This can be converted to a straight connector by cutting off the bend. To connect the PVC-U OSMA Solvent Weld Overflow system, use either Straight Tank Connector 1E129 or 90 Bent Tank Connector 1E139 (each item is supplied with two gaskets). PROCEDURE 1. Drill a hole with a saw cutter 2. Remove any burr or rough edge 3. Position a washer on either side of the cistern wall and fit the connector 4. Tighten the back nut with a spanner 5. Connect pipe. No solvent or lubricant is required For connections to screened overflow on drinking water cisterns, refer to manufacturers instructions.

Pipe bending
21.5mm Overflow pipe may be bent to a minimum of 50mm [2] radius. PROCEDURE 1. Using a blow lamp or butane torch, apply a gentle heat to the pipe approx. 50mm [2] either side of the bend 2. When the pipe is pliable, insert a standard 19mm [] bending spring 3. Pull to the required radius and restrain while pipe cools NOTE: Bending of pipe in excess of 19mm [] is not recommended

Fig. 73 Terminating overflow pipe


a)

Splay cut

b)

Tee

Overflow termination options


After penetration of the building wall, overflow pipe ends on the exterior should be terminated in one of the two following ways:
l

Fig. 74 Tundish connection to 21.5mm Solvent Weld Overflow Pipe


21.5mm Overflow pipe to cistern

Splay cut end

OR
l

Fit with a 90 Tee 1E190 to inhibit entry of freezing draughts

25mm Minimum

Connection to BSPT male thread


OsmaWeld Overflow pipework can be connected to BSPT male thread using Cap & Liner 1E156.

Tundish for overflow in basement areas


Unlike overflow systems above ground level, excess water from tanks or cisterns located in basement areas cannot be carried to a visible point on the building exterior. To ensure that any overflow is visible in areas of a building below ground level, install Tundish 1O149 along the vertical route of the overflow pipe. This should be placed as near as possible to the cistern or tank, and in a visible position. A 25mm air gap should be allowed between the end of the overflow pipe and the rim of the Tundish in order to identify the source of the discharge. IMPORTANT NOTE: Do NOT connect overflow pipework to soil and waste discharge stacks or branches
Adaptor 10158 Pipe clip 1E082

Tundish 1O149

21.5mm Overflow Pipe - OsmaWeld

Connection to BS 659 compression fittings


OSMA PVC-U Solvent Weld Overflow pipework can be connected to compression fittings manufactured to BS 659 using Straight Adaptor 1O158 or 90 Adaptor 1O159.

Fig. 75 Tundish connection to 21.5mm Push-Fit Overflow Pipe


21.5mm Overflow pipe to cistern

25mm Minimum

Tundish 1O149

21.5mm Overflow Pipe Pipe Clip 1C082

116 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Overflows

Breather Vent

Overflows continued Overflow for a range of WCs


The actual source of excess water flowing from a range of WC cisterns needs to be easily and quickly identified. To ensure that any overflow discharge is identifiable and visible in such multiple installations, install Tundish 1O149 between the overflow pipe from each cistern and a carrier manifold pipe. A 25mm air gap should be allowed between the end of the overflow pipe and the rim of the Tundish in order to identify the source of the discharge. IMPORTANT NOTE: Do NOT connect overflow pipework to soil and waste discharge stacks or branches
Discharge external to building 32mm carrier pipe Reducer 4Z343 Tee 4Z190 Bend 4Z160 Tundish 1O149 25mm Minimum

Fig. 76 Typical Tundish carrier pipe installation


Note: Overflow Pipework must not be connected to soil and waste discharge stacks or branches. 21.5mm Overflow pipe to cistern

Breather Vent
For use on mastic asphalt or built-up roofing. Breather Vent 4S700 allows moisture laden vapour to escape from the roof screed. For design detailing, please see page 100.

Mastic asphalt roofing


PROCEDURE 1. Snap off cowl from body of Vent 2. Cut a 204mm diameter hole in the asphalt and sheathing felt 3. Place the Vent directly onto the exposed roof deck 4. Pin through the holes in the Vent base 5. Apply hot asphalt over the base and dress to the cone. Terminate just above the top ridge 6. Snap-lock the cowl into position

Built-up roofing
PROCEDURE 1. Snap off cowl from body of Vent 2. Draw a 204mm diameter circle on the screed in the required position 3. Do not directly apply concrete primer or mastic to the surface within this circle 4. Place the Vent centrally on the circle 5. Pin through the holes in the Vent base 6. Apply the base layer felt up to the edge of the flange 7. Apply the second layer to the cone upto the first ridge 8. Apply the third layer to the cone up to the

Fig. 77 Installation of Breather Vent


Apertures x 4 Cowl snap-locked into position

third ridge 9. Snap-lock the cowl into position


Cowl Body

Arrows indicate direction of vapour flow Circumferential ribs for keying Asphalt finish Built-up felt finish (3 layers felt and chippings)

Mastic asphalt roofing

Built-up roofing

Email: info@wavin.co.uk

www.osma.co.uk

117

Installation

Extract Valve

Extract Valve 4S709 SW/S Extract Valve


For use with ventilation and extract systems where regulated airflows are required.

Adjusting airflow
PROCEDURE 1. Remove the snap cover plate by inserting a fine blade in the crack and twisting. The locking key is located under the cover plate 2. Calculate air flow rate and number of turns required (see Fig. 78 below) 3. Screw the adjustment plate fully home and then open by the correct number of turns to give the correct airflow (the locking key being square, may be inserted at quarter turn intervals) 4. Return locking key to prevent interference with the setting 5. Snap cover back into position

Installing valve
PROCEDURE 1. If the socket on the mounting plate is longer than the finished thickness of plaster, cut back socket to the required length. The surface on the socket is ringed to ensure a straight smooth cut using a fine toothed saw 2. Fix mounting plate to wall with rustless nails or screws through the four fixing holes provided 3. Plaster over and right up to the valve socket, the front of which should be flush with the finished surface. The ridges on the front of the plate ensure good adhesion 4. Push the valve body firmly home onto the valve socket 5. Solvent weld 110mm PVC-U pipe into the solvent socket on the reverse side of the mounting plate Fig. 78 Airflow rates for Extract Valve

number of turns open 1 1.00 .90 .80 .70 .60 .50 PRESSURE DROP INCHES W.G. .40 2 3 4 5 5

.30

.20

.10 .09 .08 20 30 40 50 60 70 80 90 100 200

AIR FLOW RATE Cfm.

118 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Installation

Maintenance

Repairs

Testing

Safety

Maintenance
OSMA Soil & Waste systems are designed to be virtually maintenance-free.

Air Admittance Valves


Periodically check that the diaphragm is clear of obstruction.

Blockages
In the event of any blockage, use only flexible or roller type rods. Metal pointed or boring types are not recommended. Mechanised rodding should be carried out by trained operators only.

Fire Stop Seals


No maintenance required. However:
l l

Regularly inspect for any damage Remove and replace any damaged seal

Cleaning Pipework
Cleaning can be undertaken with a damp cloth or mild detergent.

Repairs
If a section of the soil stack requires replacement, either to effect repair or to incorporate a fitting post construction, use D/S Double Socket 3S/4S/6S105. 3. Chamfer and lubricate the spigots of the existing pipe and fit a D/S Double Socket completely over each one 4. Position the new pipe section or assemble using socket brackets where necessary and lubricate the spigots the new spigots to position each one centrally over the joint/expansion gap 6. Fix the D/S Double Socket in place using socket brackets in their final position
Replacement Pipe or Assembly D/S Double Socket Spigot of existing pipe 12mm Expansion gap

Fig. 79 Incorporating a fitting

PROCEDURE
1. Assemble all necessary fittings to be incorporated, or prepare the required length of pipe allowing for a minimum spigot length at each end as follows: For 82mm or 110mm pipe: 60mm For 160mm pipe: 100mm 2. Cut out the appropriate length of the existing pipe, allowing for an expansion gap of 12mm at each end

5. Slide the D/S Double Socket over

D/S Double Socket

12mm Expansion gap

Spigot of existing pipe

Testing
On completion of any installation work, the systems should be inspected and tested in accordance with BS EN 12056 and Part H of the Building Regulations. Air testing is the preferred form of leak detection. The use of smoke testing of plastics pipework should be avoided.

Safety
The relevant regulations detailed in the Health and Safety at Work Act 1974 must be adhered to on site. When making solvent weld joints it is essential to observe normal safety rules for handling solvent i.e.
l l l

Close the solvent container after use and store in a cool area Do not allow solvent or cleaners to come into contact with the skin

COSHH (Control of Substances Hazardous to Health) Regulations should be referred to where applicable. Copies of data sheets are available from the Technical Design Department. Contact Wavin Technical Enquiries.

Never smoke or bring naked flames near the area of work Work in a well ventilated area to avoid inhaling fumes

Email: info@wavin.co.uk

www.osma.co.uk

119

General Information

General Information Materials


Pipes and most fittings in OSMA Soil & Waste systems are manufactured from the following materials, as individually denoted in the product listings in this Guide
Material Systems Soil systems and Solvent Weld Overflow system (pipe only) Push-Fit Waste system and Push-Fit Overflow system ABS Solvent Weld Waste system and Solvent Weld Overflow system (fittings only) PVC-C Solvent Weld Waste System

Acceptance
OSMA Soil & Waste systems comply, where applicable, with the requirements of the following British Standards:
l

References
OSMA Soil & Waste systems should be designed and installed in accordance with the guidance provided in the appropriate sections of the following:
l

BS 3943:1983 Specification for waste traps BS 4514:2001 Unplasticised PVC soil and ventilating pipes, fittings and accessories (82.4mm minimum mean outside diameter) BS 6209:1982 Solvent cement for non pressure thermoplastics pipe systems

Building Regulations 2000 (England and Wales): Approved Document H, Part H1 Building Standards (Scotland) Regulations 1993-2002 (including current amendments: Technical Standards Part M) Building Regulations (Northern Ireland) 2000: Technical Booklet N BS 8000 Workmanship on Building Sites: Part 13: 1989 Code of Practice for above ground drainage and sanitary appliances BS EN 12056: 2000 Gravity drainage systems inside buildings: Part 3 Roof drainage, layout and calculation Painting plastics: IP 11/1979. Watford, BRE 1979 Water Regulations Guide: London, Water Regulations Advisory Scheme, 2000 BS EN 752:2008 - Drain and sewer systems outside buildings

PVC-U
Unplasticised Polyvinyl Chloride

PP
Polypropylene

ABS
Acrilonytrile Butadiene Stryrene

BS EN 1329-1:2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure. PVC-U BS EN 1453-1:2000 Plastics piping systems with structured-wall pipes
l l

PVC-C
Chlorinated poly (vinyl chloride) (PVC-C)

PE
Polyethylene

V-Joint Traps

for soil and waste discharge (low and high temperature) inside buildings. Unplasticized poly (vinyl chloride) (PVC-U).
l l

BS EN 1451-1:2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure. PP BS EN 1455-1: 2000 Plastics piping systems for soil and waste (low and high temperature) within the building structure . ABS BS EN 1566-1:2000 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure. PVC-C Chlorinated poly (vinyl chloride) BS EN 12380:2002 Air admittance valves for drainage systems The British Standard Kitemark identifies pipe and fittings that are manufactured under the BSI certification scheme. OSMA Soil systems have been awarded British Board of Agrment [BBA] certification as follows:
l

Air Admittance Valve 40 and Air Admittance Valve 110 (page 51 and 66) 86/1643 110mm Adjustable Bends (page 22-23) 89/2174

120 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

General Information

General Information Health and Safety


The relevant provisions of the following legislation should be adhered to on site:
l

Abbreviations
P/E: Pipe and fittings with both ends plain or with one plain end and one special end. S/S: Pipe and fittings with one or more ring-seal or push-fit sockets, but always one plain or special end. D/S: Fittings with ring-seal or push-fit sockets at all ends. S/SW: Fittings with one or more ring-seal sockets but always one solvent socket. SW/S: Fittings with one or more solvent sockets and one plain or special end. D/SW: Fittings with solvent sockets at all ends

Supply
All OSMA systems are supplied through a nationwide network of merchant distributors. For details of your nearest stockist, contact Wavin Customer Services.

Construction (Design and Management) Regulations 1994 Control of Substances Hazardous to Health Regulations 1988 Health and Safety at Work Act 1974 Management of Health and Safety at Work Regulations 1999 Manual Handling Operations Regulations 1992

Sealing Rings
Where applicable, Sealing Rings are supplied fitted to each component and are included in the price.

l l

Conditions of sale
The Company will not accept responsibility for the malfunction of any installation which includes components not supplied by Wavin Plastics Limited. Goods are sold subject to Company conditions of sale

Hazards associated with PVC-U, PVC-C, ABS, Polypropylene and Polyethylene


There are no particular hazards associated with handling, cutting or working with the materials mentioned above, and protective clothing or equipment is not normally required. Copies of Safety Data Sheets covering PVC-U, ABS, PVC-C, PP, PE, lubricant, solvent cements and cleaners are available from the Wavin Technical Design Department. Contact Wavin Technical Enquiries.

Email: info@wavin.co.uk

www.osma.co.uk

121

Product Selector Section Index (pages 16 to 85)

PVC-U Ring Seal Soil System


Pipes Brackets Suspended Brackets Suspended Brackets (components) Sockets Connectors Reducers Bends Adjustable Bends Offset Bends Soil Manifold System Manifold Single Branches Double Branches Corner Branch Bossed Pipes Strap Bosses Boss Socket Adaptors Access Fittings Plugs 16 17 18 18 19 19-20 20-21 21-22 22-23 23-24 24 25 25-26 27 27 28-29 29 30 30-32 32

Vents
Terminal Fittings Air Admittance Valves Pipe Flashings Fire Stop Seals 50-51 51, 66 52 52, 66

Condensate Drainage
Soakaway Connectors and Adaptors 75 75-76

PVC-U & ABS Solvent Weld Overflow System


Pipe 77 77 77 77 78 78 78 79 79 Pipe Clip Socket Bends Tee Connectors Reducers Adaptors Tundish

ABS Solvent Weld Waste System


Pipe Bracket Sockets Bends Tees Cross Plug Connectors and Adaptors Reducers 53 53 53 54 55 55 55 56-58 58

PVC-C Solvent Weld Waste System


Pipe Bracket Sockets Bends Tees Plug Reducers 59 59 59 60 61 61 61

PP Push-Fit Overflow System


Pipe Pipe Clip Socket Bends Tee Connector Reudcer Tundish 80 80 80 80 80 81 81 81

PVC-U Solvent Weld Soil System


Pipe Brackets Suspended Brackets Suspended Brackets (components) Sockets Connectors Reducers Adaptor Bends Offset Bends Manifold Single Branches Double Branch Corner Branch Bossed Pipes Strap Boss Boss Socket Adaptor Access Fittings Plugs 33 33 34 34 35 35-36 36 36 37 38 38 38-39 39 40 40-41 41 41 41-42 43

PP Push-Fit Waste System


Pipe Bracket Socket Bends Tee Plug Connectors Reducers 62 62 62 63 64 64 64-65 65

Ancillaries
Cleaner Solvent Cement Lubricant Push-Fit Soil Spares 82 82 82 82-83

V-Joint Traps
90 All-Fit Conversion Bends Bottle Traps Tubular Traps Bath Traps Shower Traps Shower Gullies WasteFlow Units Washing Machine Traps 67 67-68 68-69 69-70 70 71 71-72 72-73 74 74

WC Connectors
WC Manifold Branches WC Connectors (incorporating Gasket) WC Connectors (Gasket to be fitted) WC Gasket WC Connectors (ancillaries) Easy-Fit Pan Connectors 44-45 45-46 47 47 48 48-49

Reducers Flexible Connectors

122 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Design & Installation Section Index (pages 5 to 13 and 84 to 121)


Page No
Abbreviations Acceptance Access Saddle Access - fittings - to ranges of WCs Adjusting extract valve airflow After construction connections Air Admittance Valves All-Fit Conversion Bend Applications Bath Trap and WasteFlow Unit 5V859 Biological attack Block bundles, storage of Blockages Boss sockets Bossed fittings Breather Vent Built-up roofing Chemical resistance Cleaner/Solvent Cement Usage Guide [Table 22] Cleaning pipework Conditions of Sale Connections, floor level Connection procedures: - Bath Trap Overflow - Overflow Pipe - Overflow system - Shower Gully - threaded connections Connections to Below Ground Drainage - to Other Materials - to PVC-U Connections to Drainage Connections to Waste Connections to WCs Cross flow, prevention of Drain ventilation Extract systems Extract Valve 115 115 116 115 114 107 107 107 89-90 91-93 94-97 93 99 100 118 87 87 118 93 98, 99, 112 114 85 114 102 103 119 91 91 117 117 102 105 119 121 91 Installation Procedures: - Access Saddle - Bath Trap Overflow - Boss Socket Adaptors - Breather Vent - Extract valve - Fire Stop Seals - OsmaVent 110/OsmaVent 40 - Overflow Pipe - Overflow system - pipe cutting - Pipe Flashings - replacing soil stack section - ring-seal/push-fit jointing - Short Boss Pipe 4S588 - Shower Gullies - soil connection to Other Materials - soil connection to PVC-U drainage - Soil Manifold - solvent weld jointing - Strap Bosses - Suspended Brackets - V-Joint Traps - Weathering Collar Jointing safety 108 115 110 117 118 109 112 115 116 104-105 113 119 104-105 110 115 107 107 111 105 110 106 114-115 113 105 Handling and Storage - block bundles - fire stop seals - fittings - loose pipes - safety Health & Safety Heat resistance 103, 109 103 109 103 103 103 121 102 General Information 121 121 120 87, 108 Fire Stop Seals Fire Stopping - applications - testing Fittings, storage of Floor level connections

Page No
101, 109, 119 101 101 101 103 91 Maintenance - blockages - cleaning pipework - of Air Admittance Valves - of Fire Stop Seals Mastic asphalt roofing Materials, general information - painting - physical attack - chemical resistance - heat resistance - timber preservatives - biological attack - ultra violet light - radon gas resistance Maximum Pipe Runs - of waste systems Maximum pipe support centres [Tables 20 and 23] Multiple WC connections Offsets OsmaVent OsmaVent Overflows - for a range of WCs - pipe bending - termination options Overflow system dimensions [Tables 12-15] Overflow system connections - to 3/4 BSPT male thread - to BS 659 compression fittings - to tanks and cisterns Loose pipes, storage of Lubricant Usage Guide [Table 22]

Page No
103 105 119 119 119 119 119 117 120 102 102 102 102 102 102 102 102 86 86 87, 106 106 96, 108 88, 106 98, 99, 112 98, 99, 112 116-117 117 116 116 12 116 116 116 116

Materials: Properties and Performance 102

Minimum achievable offsets [Table 24]

Offsets, minimum achievable [Table 24] 106

Email: info@wavin.co.uk

www.osma.co.uk

123

Design & Installation Section Index (pages 5 to 13 and 84 to 121)


Page No
Painting of pipes Physical attack Pipe connection to Shower Gully Pipe Cutting and Jointing Pipe Sizing [Table 19] - Soil systems - Waste systems Pipe Support Pipe Support and Offsets Pipe support centres Pipe support centres, maximum [Tables 20 and 22] Prevention of cross flow Push-fit/ring-seal jointing Radon gas areas - ventilating - resistance References Repairs Ring-seal/push-fit jointing Roof screeds ventilation Safety - on site Sealing Rings Shower Gullies Soil stack - ventilation - weatherproofing Soil system dimensions [Tables 1-4] Soil Manifold Solvent Cement/Degreasing Cleaner Usage Guide [Table 22] Solvent weld jointing 31, 45 - safety rules Storage Stub stacks Supply Support centres Suspended brackets Suspended pipework 105, 119 103 95, 99 121 87, 106 86, 106 87, 106 102 102 115 104-105 85 85 85 87 106 87, 106 Ultra violet light 87 93 104 100, 102 100 102 120 119 104 100 103, 105, 119, 121 105 103, 121 121 115 98, 113 98 113 6-7 91-92 105 Washing Machine Traps Waste system dimensions [Tables 5-10] Waste to drain connections Waste ventilation WC Manifolds WCs - back-to-back - connections direct to drainage - connections to stub stacks - multiple connections - overflow for range of WCs - planning component needs - to BS 1213 - to BS 5503 Weatherproofing Soil Stack 94 95 95 96 117 96 94 94 113 114 8-10 89-90 99 96-97, 108 Ventilation - general principles - drains - radon gas areas - roof screeds - soil stacks - stub stacks - waste V-Joint Traps V-Joint Trap dimensions [Table 11] - making solvent weld joints 98-100 98 99 100 110 98 99 99 114 11 Urinals 102 87 Testing Thermal Movement - Push-Fit systems - Solvent Weld systems Timber preservatives Traps Tundish for overflow in basement areas Tubular Trap, minimum sizes [Table 19]

Page No
119 86 86 86 102 114-115 85 116

Soil Connections to Waste 91-93, 110-111

124 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Notes

Email: info@wavin.co.uk

www.osma.co.uk

125

Notes

126 Customer Services: 0844 856 5153

Technical Advice: 0844 856 5165

Technical Fax: 0844 856 5166

Technical Advice and Assistance

Further Information

Technical Advice and Assistance


OSMA Soil and Waste systems are backed by Wavins comprehensive technical advisory service. This is available to provide expert assistance at every stage of a project, from planning and product selection to installation and maintenance. Services include:
l

Further Information
OSMA SOIL AND WASTE SYSTEMS The following related publications are available for OSMA Soil and Waste systems:
l

Trade Price List

ASSOCIATED OSMA SYSTEMS OSMA systems are fully integrated to provide a total solution for above and below ground drainage, plumbing and heating. Visit www.wavin.co.uk for details of our full product range:
l l l l

Full technical literature, including: - System Product Guides - Design and Installation Guides - Trade Price Lists Assistance with systems product selection

Rainwater Systems Flexible Plumbing systems Underfloor Heating systems Below Ground Drainage systems

On site advice and troubleshooting Contact Wavin Technical Design Department for prompt assistance: TECHNICAL DESIGN Tel: 0844 856 5165 Fax: 0844 856 5166 Email: technical.design@wavin.co.uk

WAVIN ONLINE For further information on OSMA systems and PDF verisons of our current literature, please visit our website www.osma.co.uk

Email: info@wavin.co.uk

www.osma.co.uk

127

Above and below ground drainage by Wavin

Soil & Waste Systems Product, Design and Installation Guide

OSMA is the UKs leading name in plastics systems, your single source for all types of gravity drainage, sewer installation and pressure pipe systems in any private or public development. Our high-quality and innovative systems are fully tested and kitemarked and are supported by design and after sales service.

Wavin operates a programme of continuous product development, and therefore reserves the right to modify or amend the specification of their products without notice. All information in this publication is given in good faith, and believed to be correct at the time of going to press. However, no responsibility can be accepted for any errors, omissions or incorrect assumptions. Users should satisfy themselves that products are suitable for the purpose and application intended.

Wavin Limited Registered Office Hazlehead Crow Edge Sheffield S36 4HG

www.osma.co.uk

SW206

Solutions for Essentials

You might also like