SubstiTUBE ST8-SD4
Datasheet VDE certified innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 50% by replacing 36W T8 fluorescent tubes. Applicable in warehouses, supply rooms, corridors, industry, stairways, garages, indirect illumination etc; for applications with high operating hours.

Technical operating data


Product ST8-SD4-765 ST8-SD4-840 ST8-SD4-830 Color Daylight White Warm White Colortemp. [K] 6500 K 4000 K 3000 K Lum. Flux [lm] 1550 1200 1200 230 V 50 Hz 23,5 W 70 x 90 Voltage [V] / Frequency [Hz] Power [W] RadianceAngle []

All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data.

Technical Features LED lamp in T8 shape with G13 socket Length: 1.212 m; Weight: 420 g 18 high-performance OSLON LEDs Nominal Power: 23.5 W For operation with CCG No rewiring necessary; Luminaire certifications remain valid Direct Retrofit for CCG luminaires; replacement of lamp and included starter Extremely robust with aluminium heat sink and polycarbonate cover Full integrated ECG complies to relevant standards Complies with safety standard for self balasted LED lamps IEC 62560; VDE certificied Up to 50.000 h lifetime Overpower, overheat, short and open circuit protected FineWhite / ANSI Binning for highest homogeneity Not for operation with ECG, not dimmable

ST8-SD4 08.02.2011

Page 1 von 4

Minimum / Maximum ratings


Ambient temperature Operating temperature Ta Tc ST8-SD4-xx -30 50C -30... 75C Storage temperature Ts -30 ... 85 C

Drawings

Tc

Height [m]

Diameter [m] 1,99 1,44 3,98 2,89 5,96 4,33 7,95 5,78 9,94 7,22

Illumination 4000 K / 3000 K Emax [lx] Emed [lx] 586 147 65 37 23 236 59 26 15 9

Illumination 6500 K Emax [lx] Emed [lx] 741 185 82 46 30 298 74 33 19 12

1 2 3 4 5

VDE
REG.-Nr. D457

ST8-SD4 08.02.2011

Page 2 von 4

Safety and Application notes The SubstiTUBE must not be damaged or operated in a damaged condition. When operating with CCG, the included SubstiTUBE Start has to be inserted as well. If the conventional starter is not replaced the SubstiTUBE will start blinking. Switch off immediately, the SubstiTUBE can be damaged! Do not use SubstiTUBE in luminaires which do not have any starter or when the starter cannot be replaced. The SubstiTUBE emits light only with a limited angle, not like a fluorescent tube with 360output. Due to the characteristic light distribution of the SubstiTUBE, the current luminaire light characteristic will likely change. It is not guaranteed that e.g. standards for lighting at working places will be complied to after replacement. A photometric check of the installation is recommended. The effective energy savings depend on the efficiency of the luminaire setup to be replaced and should be considered individually in each case. Particularly ballast losses are reduced to ohmic losses and are normally only about 1 W 1,5 W. The SubstiTUBE is protected according to IP20. Applications with external risk of moisture and dust can be served with an adequately protected luminaire. SubstiTUBE may also be driven directly on line voltage. We strongly recommend to refer to the application note for installation information.

ST8-SD4 08.02.2011

Page 3 von 4

Installation Instructions Make sure that the supply voltage is disconnected. Carefully remove the fluorescent tube and starter according to the lamp holder type. Insert SubstiTUBE and SubstiTUBE Start properly. Below an example for typical lamp holder types is described Turn the conventional lamp 90 degrees and take it out of the socket. Remove the conventional starter by turning it. Insert and latch the SubstiTUBE Start into starter socket. Insert SubstiTUBE into socket and locate into position by turning 90. Check light distribution angle.

For further installation options please see the Application Note

Ordering guide
Productname ST8-SD4-765 ST8-SD4-840 ST8-SD4-830 Light color Daylight / 6500 K White / 4000 K Warm White / 3000 K EAN* 4008321966063 4008321966056 4008321966049 10 x 1 VPE*

* EAN: Ordering number per single module S-Unit: Module per shipping unit

Sales and Technical Support


OSRAM GmbH Hellabrunner Strasse 1 D - 81536 Mnchen Germany www.osram.com +49 (0)89 6213-0 Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all OSRAM subsidiaries are listed with complete address and phone numbers.

Further Information
Brochure A new approach to light www.osram.com/led-systems-downloads 1EZW001GB www.osram.com/led-systems-downloads 400D125GB www.osram.com/led-systems-downloads 1EBW004GB www.osram.com/downloads
Page 4 von 4

Brochure Better light in every respect. Flyer OSRAM SubstiTUBE Downloads: Application note, eulumdat files
ST8-SD4 08.02.2011