Professional Documents
Culture Documents
Bearing Bar in welded & press locked grating (Aw) Number of Bearing Bar per meter grating width (K) Allowable yield stress for SS316L grating (F) Modulus of Elesticity (E)
= =
5 30
mm mm
= = = = = =
0.00002475
m3
Moment of Interia of garing per meter width (Iw) = Kbd^3/12 Maximum Unstiffening Span length (L) Maximum Bending Moment for grating per meter of width (Mw)=F*Sw Design For Load case 1 - Concentrated Load at Center Maximum Bending Moment (Mw) = PL/4
= =
3.7125E-07 1
m4 m
4.2075
KN-m
so Maximum allowable concentrated load on grating per meter(P) = 4 Mw / L = 16.83 Actual concentrated load on grating are (P) actual = 4.5 So Actual laod P(actual) < Max.Allowable load , so grating are safe in Bending as per Table 1 of SAES-M-001 Maximum bending deflection due to actual concentrated load (DL) = PL^3 / 48EI
KN KN
= =
1.263E-03 1.26
mtr mm
Design For Case 2 - Uniform Distributed Load over 1m^2 span Maximum Bending Moment (Mw) = wl^2 / 8 So maximum allowable uniform load on grating per meter sq. w= [(Mw*8)/l^2 ]/l Actual Distributed load on grating are (P) actual per meter sq.
= =
33.66 3.6
KN/m2 KN/m2
So Actual laod P(actual) < Max.Allowable load , so grating are safe in Bending as per Table 1 of SAES-M-001 Maximum bending deflection due to actual uniform load (DL) = 5PL^4 / 384EI
= =
6.3131E-04 0.63
mtr mm