ITEM REF.
BILL OF QUANTITIES
BILL NO 4
UNIT RATE UNIT RATE (IN WORDS)
Page 4/15
ITEM DESCRIPTION
QTY
UNIT
AIR CONDITIONING INSTALLATION Wall mounted split Unit including Refrigerant piping, integral controls, control box and standard remotely located unit inclusive of all necessary electrical and plumbing connections and fittings valves and holding down bolts all in accordance with detail drawing and specification. Wall Mounted Split unit 1.5 Tr Wall Mounted Split unit 2.0 Tr
1 6 No No
Supply, Install, Testing & commissioning of wall/window Mounted Extract fan including all accessories as specified. A Extract fan in guard house
2 No
To Collection
BILL OF QUANTITIES
BILL NO 4
UNIT RATE UNIT RATE (IN WORDS)
Page 4/16
ITEM DESCRIPTION
QTY
UNIT
SUNDRIES
Supply Installation of Necessary airtight partition at above false ceiling all as per drawings, specifications and satisfaction of consultant.
Allow for providing working drawings Allow for necessary pipe supports, bracket fixings and the like Allow for setting out the work and marking positions of all holes, mortises, chases and the like Allow for identification labels, plates, charts and identification of plant, equipment pipe work, controls and the like Allow for testing and commissioning and production of test certificates.
B C D
Item
1 Allow for preparing schedule of manufacturer's recommended tools and spare parts for each pieces of equipment. Allow for spare parts and tools.
Item
G H
1 1
Item Item
To Collection
BILL OF QUANTITIES
BILL NO 4
UNIT RATE UNIT RATE (IN WORDS)
Page 4/17
ITEM DESCRIPTION
QTY
UNIT
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/72
ITEM DESCRIPTION
QTY
UNIT
AIR CONDITIONING INSTALLATION Equipment Supply, install, test and commisioning of Air handling unit (Re-Circulating type) with conderser unit as described complete with cooling coil, fans, motor, filters, heater battery, louver, condensate pan, anti-vibration mountings, concrete base and condensate drains, flexible connections to ductwork and electrical connections, refer specification and equipment schedule. A B AHU-02 AHU-03
1 1 No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/73
ITEM DESCRIPTION
QTY
UNIT
Supply and install, test commission and handover, floor mounted Package unit (Re-Circulating type) described complete with cooling coil, fans, motor, filters, heater battery, louver, condensate pan, anti-vibration mountings, concrete base and condensate drains, inclusive of all necessary electrical and plumbing connections and fittings, 2 port valves, holding down bolts or the like and in accordance with the drawing and specification. A PAC-01 Allow for Control System for Air Handling Unit & Package Unit including interconnecting wiring for all control items, motors, sensors and the like as the specification
1 No
Item
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/74
ITEM DESCRIPTION
QTY
UNIT
Supply and install, test commission and handover, floor mounted VRV/VRF unit s described complete with cooling coil, refrigerant pipes, insulations, fans, motor, filters, heater battery, louver, condensate pan, anti-vibration mountings, concrete base and condensate drains, refrigerant pipe trays, brackets inclusive of all necessary electrical and plumbing connections and fittings, 2 port valves, holding down bolts or the like and in accordance with the drawing and specification. A B C D E F G H VRV-01 VRV-02 VRV-03 VRV-04 VRV-05 VRV-06 VRV-07 VRV-08 To Collection
1 1 1 1 1 1 1 1 No No No No No No No No
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/75
ITEM DESCRIPTION
QTY
UNIT
VRV/VRF unit . A B C D E F G H J K L VRV-09 VRV-10 VRV-11 VRV-12 VRV-13 VRV-14 VRV-15 VRV-16 VRV-17 VRV-18 VRV-19
1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/76
ITEM DESCRIPTION
QTY
UNIT
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/77
ITEM DESCRIPTION
QTY
UNIT
Supply and install, test commission and handover, Ceiling/Wall mounted fan coil unit including integral controls ,motororized valves, refrigerant pipes, insulations, DRV, and factory fitted 3 way cassette on/off control valves, refrigerant pipe trays, brackets, control box and standard remotely located unit inclusive of all necessary electrical and plumbing connections and fittings valves and holding down bolts all in accordance with detail drawing and specification. All as per Equipment schedule A B C D E F FCU/GF-01 FCU/GF-03 FCU/GF-04 FCU/GF-07 FCU/GF-08 FCU/GF-10
1 1 1 1 1 1 No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/78
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J K L M FCU/GF-13 FCU/GF-14 FCU/GF-15 FCU/GF-16 FCU/GF-20 FCU/GF-21 FCU/GF-22 FCU/GF-23 FCU/GF-24 FCU/GF-26 FCU/GF-27 FCU/GF-29 To Collection
1 1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No No
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/79
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J K L M FCU/GF-30 FCU/GF-31 FCU/GF-32 FCU/GF-33 FCU/GF-34 FCU/GF-35 FCU/GF-36 FCU/GF-37 FCU/GF-38 FCU/GF-39 FCU/GF-40 FCU/GF-41 To Collection
1 1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No No
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/80
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J K L FCU/GF-43 FCU/GF-44 FCU/GF-45 FCU/GF-46 FCU/GF-47 FCU/GF-47A FCU/GF-47B FCU/GF-47C FCU/GF-48 FCU/GF-48A FCU/GF-48B
1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/81
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J J K L M FCU/GF-48C FCU/GF-51 FCU/GF-52 FCU/GF-53 FCU/GF-55 FCU/GF-56 FCU/GF-57 FCU/GF-58 FCU/GF-59 FCU/GF-60 FCU/GF-61 FCU/GF-62 FCU/GF-63 To Collection
1 1 1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No No No
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/82
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J K L FCU/GF-64 FCU/GF-65 FCU/GF-66 FCU/GF-67 FCU/GF-68 FCU/GF-72 FCU/GF-74 FCU/GF-75 FCU/GF-79 FCU/GF-80 FCU/GF-81
1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/83
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J K L FCU/GF-82 FCU/GF-83 FCU/GF-89 FCU/GF-92 FCU/GF-95 FCU/GF-96 FCU/GF-103 FCU/GF-110 FCU/GF-114 FCU/GF-115 FCU/GF-116
1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/84
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J K L FCU/GF-118 FCU/GF-120 FCU/GF-121 FCU/GF-124 FCU/GF-125 FCU/GF-126 FCU/GF-127 FCU/GF-128 FCU/GF-129 FCU/GF-130 FCU/GF-131
1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/85
ITEM DESCRIPTION
QTY
UNIT
Ceiling/Wall mounted fan coil unit . A B C D E F G H J K FCU/MF-01 FCU/MF-06 FCU/MF-13 FCU/MF-14 FCU/FF-01 FCU/FF-02 FCU/FF-03 FCU/FF-04 FCU/FF-08 FCU/FF-09
1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/86
ITEM DESCRIPTION
QTY
UNIT
Split type air conditioning unit comprising air cooled condensing unit and WALL mounted air conditioning unit complete with interconnecting insulated refrigerant pipe work and ancillaries, gas charge, anti-vibration mountings, necessary concrete base, fans, filters, coils, controls, connections to condensate drainage and electrical connections as described A B C D Wall Mounted Split unit 1.0 Tr Wall Mounted Split unit 1.5 Tr Wall Mounted Split unit 2.0 Tr Wall Mounted Split unit 2.5 Tr Cassette Unit including Refrigerant piping, integral controls, control box and standard remotely located unit inclusive of all necessary electrical and plumbing connections and fittings valves and holding down bolts all in accordance with detail drawing and specification. E F G Cassette Unit 1.0 Tr Cassette Unit 1.5 Tr Cassette Unit 2.0 Tr To Collection
2 5 6 No No No 4 38 20 4 No No No No
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/87
ITEM DESCRIPTION
QTY
UNIT
Supply and Installation of Sheet metal ductwork to HVAC DW 144 including, fittings, supports, hangers, stiffeners, tapering section, VRV bends and protective coating, acostic lining etc., A Ductwork to HVAC DW 144 having thickness of 22 gauge Supply and Installation of Phenolic fome Pre insulated ductwork including, fittings, supports, hangers, stiffeners, tapering section, VRV bends and protective coating, acostic lining etc., B Phenolic fome Pre insulated duct as specified.
2210 Sqm 50 Sqm
Supply and Installation of pvc ductwork as specified including, fittings, supports,hangers, stiffeners, tapering section, VRV bends and protective coating, acostic lining etc., C PVC duct work
110 Sqm
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/88
ITEM DESCRIPTION
QTY
UNIT
Supply and Installation of Flexible duct with Spigot connection to fan coil units and AHU s as per drawings and specifications. Supply and Installation of necessary duct insulation all as per drawings and specifications. Supply and Installation of necessary duct insulation in roof all as per drawings and specifications. Supply and Installation of necessary aluminum cladding for exposed (roof) ducts all as per drawings and specifications. Supply Installation of Necessary airtight partition at above false ceiling all as per drawings, specifications and satisfaction of consultant. Fresh air intake with louver, wire mesh filter, sand arrester with trap, opposed blade, manual volume control damper, filter and guides, insect screen, gasketted flanged joints and damper quadrant and locked as described
Item
Item
Item
Item
Item
Item
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/89
ITEM DESCRIPTION
QTY
UNIT
Supply and Installation of linear bar supply/return grills for Supply and Return including plenum box A B C 900mm x 150mm Long 750mm x200mm Long 150mm x150mm Long Supply and Installation of 4-Way square supply air diffusers with flexible connection, built-in damper etc., all as specified and directed. D E 300mm x 300mm 375mm x 375mm Supply and Installation of External Fresh/Extract Grille with sand trap louvered including plenum box F G 800mm x 250mm Long 110 Dia. Fresh Air Grille
4 10 No No 67 180 No No 10 14 3 No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/90
ITEM DESCRIPTION
QTY
UNIT
Supply and Installation of 4-Way square return air diffusers all as specified and directed. A B 300mm x 300mm 375mm x 375mm Supply and installation of necessary flexible ducts with Spigot connection between main ducts to plenum box all as per drawings and specifications.
63 192 No No
Item
Supply and Installation of Jet diffusers with flexible connection, built-in damper etc., all as specified and directed. D 400mm Dia. Supply and Installation of 3 Slot linear Supply/Return grills including plenum box with flexible connection, built-in damper etc., all as specified and directed.
10 No
305
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/91
ITEM DESCRIPTION
QTY
UNIT
Supply and Installation of Volume control Damper as specified A B C D E F G H J 800mm x 300mm 650mm x 400mm 650mm x 300mm 600mm x 200mm 550mm x 350mm 550mm x 300mm 450mm x 300mm 400mm x 400mm 400mm x 300mm
1 2 2 10 2 1 7 4 1 No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/92
ITEM DESCRIPTION
QTY
UNIT
Supply and Installation of Volume control Damper A B C D E F 350mm x 300mm 300mm x 300mm 300mm x 250mm 250mm x 200mm 200mm x 200mm 150mm x 150mm Sound attenuator complete as described and fitted to ductwork and built into structure including all necessary transformation pieces and insulating to match surrounding ductwork G H J 1050mm x 550mm 850mm x 450mm 650mm x 650mm To Collection
1 1 2 No No No 10 109 8 4 2 16 No No No No No No
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/93
ITEM DESCRIPTION
QTY
UNIT
SUNDRIES
Allow for final connections to fan coil units/AHUs in light gauge copper to BS2871 Table X Allow for providing fresh air pipe supply to all FCU's, Cassette units etc including the pipe works and supply air grill on the external wall etc.. Design, supply, install test and commisioning of duct work, differsers, vcd's,bell mouths , etc in the theatre area from AHU03 coordinating with all the stage equipments all as per specification & BSEN / Local Standards Supply and fix the return air diffusers in the theatre area for AHU-04 corodinating with all the theatre lighting and false ceiling as specified. Provide condensate drain pipe for air handling units, fan coil units, split air conditioning units and condenser unit and connect to nearest drainage point including necessary insulated pipe work as specified
Item
Item
Item
Item
Item
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/94
ITEM DESCRIPTION
QTY
UNIT
VENTILATION Supply installation testing and commission of duct work DW 143 for extract system complete with ducts, diffusers, supports, hawsers, sniffers, VCD ,etc., as per drawing and specification. A B C 200mm x 200mm 200mm x 150mm 150mm x 150mm Supply and Installation of Extract air diffusers with built in VCD of following sizes with flexible connectors, etc., all complete as specified and directed. D 150mm x 150mm
99 No 50 25 120 Sqm Sqm Sqm
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/95
ITEM DESCRIPTION
QTY
UNIT
Supply, Install, Testing & commissioning of inline ducted Extract & Supply fan including all accessories as specified A B C D SAF-01 SAF-02 EAF-01 EAF-02 Supply, Install, Test & commissioning of wall/window mounted explosion proof Extract fan duty standby including all accessories as specified E EF/CH-01
1 No 1 1 1 1 No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/96
ITEM DESCRIPTION
QTY
UNIT
Supply, install, testing & commissioning of inline ducted/wall/window mounted extract fan including all accessories as specified. A B C D E F G H J K EF-1 EF-2 EF-3 EF-4 EF-5 EF-6 EF-7 EF-8 EF-9 EF-10 To Collection
1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/97
ITEM DESCRIPTION
QTY
UNIT
Supply, install, testing & commissioning of inline ducted.. A B C D E F G H J K L EF-11 EF-12 EF-13 EF-14 EF-15 EF-16 EF-17 EF-18 EF-19 EF-20 EF-21
1 1 1 1 1 1 1 1 1 1 1 No No No No No No No No No No No
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/98
ITEM DESCRIPTION
QTY
UNIT
Supply, install, testing & commissioning of inline ducted.. A B C D E F EF-22 EF-23 EF-24 EF-25
1 1 1 1 No No No No No 1 No
EF-26 EF-27
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/99
ITEM DESCRIPTION
QTY
UNIT
SUNDRIES
Supply and Installation of Flexible duct with Spigot connection to fan coil units and AHU s as per drawings and specifications. Supply and Installation of necessary duct insulation all as per drawings and specifications. Supply and Installation of necessary duct insulation in all plant rooms all as per drawings and specifications. Supply and Installation of necessary duct insulation with aluminum cladding for ducts all as per drawings and Supply and installation of stainless steel metal expansion bellows for the ducts in expansion joints as specified Supply Installation of Necessary airtight partition at above false ceiling all as per drawings, specifications and satisfaction of consultant. Allow for passive fire stopping system as per specification
Item
Item
Item
Item
Item
Item
Item
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/100
ITEM DESCRIPTION
QTY
UNIT
A B C
Allow for providing working drawings Allow for necessary pipe supports, bracket fixings and the like Allow for setting out the work and marking positions of all holes, mortises, chases and the like Allow for identification labels, plates, charts and identification of plant, equipment pipe work, controls and the like Allow for testing and commissioning and production of test certificates.
1 1
Item
1 Allow for preparing schedule of manufacturer's recommended tools and spare parts for each pieces of equipment. Allow for spare parts and tools.
Item
F G
1 1
Item Item
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/101
ITEM DESCRIPTION
QTY
UNIT
HVAC WORKS COLLECTION 3/72 3/73 3/74 3/75 3/76 3/77 3/78 3/79 3/80 3/81
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/102
ITEM DESCRIPTION
QTY
UNIT
Collection From Above 3/82 3/83 3/84 3/85 3/86 3/87 3/88 3/89 3/90 3/91 3/92
To Collection
BILL OF QUANTITIES
BILL NO 3
UNIT RATE UNIT RATE (IN WORDS)
Page 3/103
ITEM DESCRIPTION
QTY
UNIT
Collection From Above 3/93 3/94 3/95 3/96 3/97 3/98 3/99 3/100