12V 100Ah
GPL 121000 is a general purpose battery up to 10
years expected life under normal float charge
As with all CSB batteries, all are rechargeable,
highly efficient, leak proof and maintenance free.
Specification
Cells Per Unit
Voltage Per Unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
6
12
100Ah @ 20hr-rate to 1.75V per cell @25 (77 )
Approx. 33.5 kg(73.86 lbs)
800A(5sec)
Approx. 3.5m
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Nominal Operating Temperature Range 25
3 (77
5 )
Float Charging Voltage
13.5 to 13.8 VDC/unit Average at 25 (77 )
Recommended Maximum Charging
30A
Current Limit
Equalization and Cycle Service
14.4 to 15.0 VDC/unit Average at 25 (77 )
Self Discharge
CSB Batteries can be stored for more than 6 months at
25 (77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
I2-Thread lead alloy recessed terminal to accept M6 bolt
Container Material
Polypropylene(UL 94-V0/File E50955)*Flammability resistance
of (UL 94-HB/File E216959) can be available upon request.
CSB-manufactured
batteries are ULrecognized components
under UL924 and
UL1989.
CSB is also certified by
ISO 9001 and
ISO 14001.
Dimensions
unit: (MM)
5MIN
433
388
366
330
290
250
10MIN
287
263
253
234
215
196
15MIN
214
198
193
183
171
161
30MIN
124
120
118
113
108
103
1HR
71.2
69.7
69.0
67.6
65.6
63.6
2HR
40.3
39.7
39.4
38.8
38.1
37.5
3HR
28.7
28.2
28.0
27.5
26.9
26.4
4HR
22.3
22.0
21.9
21.6
21.2
20.9
5MIN
4,560
4,162
3,972
3,625
3,251
2,855
10MIN
3,150
2,905
2,783
2,580
2,360
2,140
15MIN
2,371
2,223
2,150
2,037
1,897
1,774
30MIN
1,420
1,368
1,342
1,290
1,238
1,185
1HR
830
814
806
789
773
753
2HR
472
465
461
454
445
437
3HR
337
333
331
326
320
315
77
Unit:A (25
5HR
18.4
18.2
18.1
17.9
17.7
17.3
Unit:W (25
4HR
263
262
261
257
252
248
5HR
218
216
214
213
212
207
8HR
12.5
12.4
12.3
12.1
11.9
11.7
)
10HR
10.5
10.4
10.3
10.2
10.0
9.80
,77
8HR
149
148
147
146
143
141
20HR
5.42
5.38
5.36
5.31
5.25
5.20
)
10HR
126
125
124
123
121
119
20HR
71.0
70.6
70.4
69.2
67.9
66.7
GPL 121000
140
0.20
2.60
120
0.17
2.40
100
0.14
2.20
80
0.11
2.00
60
0.08
1.80
40
0.05
1.60
20
0.02
1.40
12V 100Ah
)Ratio
13.65V
140
0.20
2.60
120
0.17
2.40
100
0.14
2.20
80
0.11
2.00
60
0.08
1.80
40
0.05
1.60
20
0.02
1.40
Application
(2.275V/Cell)
12
16
20
24
68
)Ratio
12
16
Charge Voltage(V/Cell)
Set Point
Allowable Range
Cycle Use
Temperature
25(77)
2.45
2.40~2.50
Standby
25(77)
2.275
2.25~2.30
20
24
Max.Charge Current
Final Discharge
Voltage V/Cell
1.75
1.70
1.60
1.30
0.3C
Discharge
Current(A)
0.2C>(A)
0.2C<(A)<0.5C
0.5C<(A)<1.0C
(A)>1.0C
Tel: +886-2-2555-5600
Fax: +886-2-2555-3300
BEIJING OFFICE
Tel : +86-10-59621300/59621301/59621302/59621303
Fax : +86-10-59621304
mail : chinasls@csb-battery.com
SHENZHEN OFFICE
Tel : +86-755-8831-6488/6396/16356
Fax : +86-755-8831-6548
mail : she@csb-battery.com.cn
E-mail: chinasls@csb-battery.com