You are on page 1of 427

2600-00FET7GAT

Ver. 6.0

LTE eNB

System Counter Description_SLR 2.4

2600-00FET7GAT

Ver. 6.0

COPYRIGHT
This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright. No information contained herein may be copied, translated, transcribed or duplicated for any commercial purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics Co., Ltd.

TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective companies.

This manual should be read and used as a guideline for properly installing and operating the product.

All reasonable care has been made to ensure that this document is accurate. If you have any comments on this manual, please contact our documentation centre at the following address: Address: Document & Training Center 3rd Floor Jeong-bo-tong-sin-dong. 129, Samsung-ro, Yeongtong-gu, Suwonsi, Gyeonggi-do, Korea 443-742 Homepage: http://www.samsungdocs.com

2013 SAMSUNG Electronics Co., Ltd.

All rights reserved.

2600-00FET7GAT

Ver. 6.0 INTRODUCTION

INTRODUCTION

Purpose
LTE eNB System Counter Description provides detailed information for each statisti cal item for statistics data analysis.

Document Content and Organization


This manual consists of one Chapter. Statistics Items Provides the definition, index, statistic types and collection time for each statistics it em.

Conventions
The following types of paragraphs contain special information that must be carefully read and thoroughly understood. Such information may or may not be enclosed in a rectangular box, separating it from the main text, but is always preceded by an icon and/or a bold title.

NOTE Indicates additional information as a reference.

Relevance
This manual applies to the following Samsung network software releases:
Technology LTE Software Release SLR 2.4

SAMSUNG Electronics Co., Ltd.

page 3 of 427

2600-00FET7GAT

Ver. 6.0 INTRODUCTION

Related Document
Listed below is the entire document set of the product:
Document Feature Description Describes features across a Samsung telecommunications networks products. Software Block Description software blocks across a Samsung telecommunications networks products. Command Description commands across a Samsung telecommunications networks products. Printout message Description printout messages across a Samsung telecommunications networks products. Network Planning Manual network plans across a Samsung telecommunications networks products. Optimisation Manual optimisation guidelines across a Samsung telecommunications networks products. Product Description Dimensioning Manual System Parameter Description System Counter Description Installation Manual Commissioning and Integration Manual Operation Manual Maintenance Manual Hardware Inspection and Replacement Manual EMS User Manual the Element Management System (EMS) from Samsung. the product. dimensioning in the product. system parameters used in the product. counters in the product. the installation of the Product. commissioning and integration of the product. operation of the product. maintenance of the product. hardware inspection and replacement of the product.

SAMSUNG Electronics Co., Ltd.

page 4 of 427

2600-00FET7GAT

Ver. 6.0 INTRODUCTION

WEEE Symbol Information


This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.

BATTERY Symbol Information


Correct disposal of batteries in this product

(Applicable in countries with separate collection systems.) The marking on the battery, manual or packaging indicates that the battery in this product should not be disposed of with other household waste. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. The battery incorporated in this product is not user replaceable. For information on its replacement, please contact your service provider. Do not attempt to remove the battery or dispose it in a fire. Do not disassemble, crush, or puncture the battery. If you intend to discard the product, the waste collection site will take the appropriate measures for the recycling and treatment of the product, including the battery.

SAMSUNG Electronics Co., Ltd.

page 5 of 427

2600-00FET7GAT

Ver. 6.0 INTRODUCTION

Revision History
VERSION 6.0 DATE OF ISSUE 07. 2013. - Changed 3.3 RRC Connection Reestablishment 5.0 06. 2013. - Changed 3.7 RRC Connection Reestablishment Time 5.4 S1 Handover Out 24.6 MOBILITY 4.0 06. 2013. - Changed 24.3 RETAINABILITY (QCI) 3.0 05. 2013. - Granularity Formula field of each Statistics item is added. - Visible field of each Statistics item is added. 2.0 03. 2013. - Changed 18.1 MIMO performance - Deleted 6 HO HRPD 8 HO 1XRTT - Added 2.6 VPN Interface 6.3 UTRAN SRVCC 23.3 RETAINABILITY (QCI) 23.8 Connection Drop Rate 1.0 02. 2013. First Version REMARKS

SAMSUNG Electronics Co., Ltd.

page 6 of 427

2600-00FET7GAT

Ver. 6.0 TABLE OF CONTENTS

TABLE OF CONTENTS
INTRODUCTION 3

Purpose ..................................................................................................................................................... 3 Document Content and Organization ...................................................................................................... 3 Conventions............................................................................................................................................... 3 Relevance .................................................................................................................................................. 3 Related Document .................................................................................................................................... 4 WEEE Symbol Information ....................................................................................................................... 5 BATTERY Symbol Information ................................................................................................................. 5 Revision History ........................................................................................................................................ 6

Statistics Items
1

12

Resource Management............................................................................................................13 1.1 Resource ..................................................................................................................................... 13

Packet Statistics ......................................................................................................................16 2.1 2.2 2.3 2.4 2.5 2.6 Ethernet Interface ....................................................................................................................... 16 Histogram .................................................................................................................................... 24 Air Mac UL/DL bytes (Kbytes).................................................................................................... 26 Air RLC UL/DL bytes .................................................................................................................. 29 S-GW UL/DL packets ................................................................................................................. 33 VPN Interface.............................................................................................................................. 36 .......................................................................................................................................37 RRC Connection Establishments .............................................................................................. 39 RRC Connection Reconfiguration ............................................................................................. 43 RRC Connection Reestablishment............................................................................................ 45 RRC Connection Release .......................................................................................................... 49 RRC Connection number ........................................................................................................... 54 RRC Connection Setup Time..................................................................................................... 56 RRC Connection Reestablishment Time .................................................................................. 59 Call Drop ..................................................................................................................................... 62

RRC 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8

ERAB .......................................................................................................................................65 4.1 E-RAB Setup .............................................................................................................................. 65

SAMSUNG Electronics Co., Ltd.

page 7 of 427

2600-00FET7GAT

Ver. 6.0 TABLE OF CONTENTS

4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 5

E-RAB Setup Add .......................................................................................................................69 E-RAB Setup Time .....................................................................................................................73 eNB E-RAB Erase Request .......................................................................................................75 E-RAB Erase ...............................................................................................................................78 E-RAB Modify .............................................................................................................................80 eNB E-RAB Release Request ...................................................................................................84 E-RAB Release ...........................................................................................................................86 E-RAB Activity (UE) ....................................................................................................................88 E-RAB Activity (QCI) ...................................................................................................................89 E-RAB Simultaneous Number ...................................................................................................90

Handover (HO) EUTRAN ......................................................................................................... 91 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 Intra eNB Handover ....................................................................................................................98 X2 Handover Out ......................................................................................................................103 X2 Handover In .........................................................................................................................109 S1 Handover Out ...................................................................................................................... 115 S1 Handover In .........................................................................................................................120 Handover Time (Average, Max) ...............................................................................................125 Outgoing Intra-Frequency Handover .......................................................................................130 Outgoing Inter-frequency Handover with Measurement Gap ................................................135 Outgoing Inter-frequency Handover without Measurement Gap ...........................................141 Outgoing Handover with DRX ..................................................................................................148 Outgoing Handover without DRX.............................................................................................152

HO UTRAN ............................................................................................................................. 157 6.1 6.2 6.3 6.4 6.5 6.6 Inter-RAT UTRAN PS Handover OUT ....................................................................................160 Inter-RAT UTRAN PS Handover IN .........................................................................................164 UTRAN SRVCC ........................................................................................................................169 CS Fall Back (CSFB) PS Handover OUT ...............................................................................172 CS FallBack (CSFB) without PS Handover Out (Redirection) ...............................................177 PS Redirection UTRAN Out .....................................................................................................179 ..................................................................................................................................... 180 Call Fail Report .........................................................................................................................180

CSL 7.1

MRO_RLF ............................................................................................................................... 213 8.1 MRO RLF Classification ...........................................................................................................213 ..................................................................................................................................... 215 GTP Sequence Number by QCI ..............................................................................................215 GTP Sequence Number by eNB .............................................................................................216 GTP Forward Traffic .................................................................................................................218 ..................................................................................................................................... 231

GTP 9.1 9.2 9.3

10

SRB

SAMSUNG Electronics Co., Ltd.

page 8 of 427

2600-00FET7GAT

Ver. 6.0 TABLE OF CONTENTS

10.1 11 DRB 11.1 11.2 11.3 11.4 11.5 12 RRU 12.1 12.2 12.3 13

Cell PDCP SDU bit-rate ........................................................................................................... 231 .....................................................................................................................................233 Active UEs................................................................................................................................. 233 Packet Delay ............................................................................................................................. 235 Packet Drop Rate ..................................................................................................................... 236 Packet Loss Rate (ppm)........................................................................................................... 238 IP Latency measurements ....................................................................................................... 240 .....................................................................................................................................241 DL/UL PRB Usage.................................................................................................................... 241 DL/UL Total PRB Usage ........................................................................................................... 243 Cell Unavailable Time ............................................................................................................... 247

S1SIG .....................................................................................................................................248 13.1 13.2 UE-associated logical S1-connection establishment.............................................................. 248 S1 Connection Time ................................................................................................................. 251 .....................................................................................................................................252 Paging Performance................................................................................................................. 252

14

PAG 14.1

15

Power .....................................................................................................................................254 15.1 15.2 15.3 Power ........................................................................................................................................ 254 RNTP of own cell ...................................................................................................................... 256 RRH_RSSI ................................................................................................................................ 262 .....................................................................................................................................263 Random Access Preambles..................................................................................................... 263

16

RA 16.1

17

HARQ .....................................................................................................................................265 17.1 DL/UL Transmission ................................................................................................................. 265

18

Timing Alignment ...................................................................................................................277 18.1 Timing Alignment ...................................................................................................................... 277 .....................................................................................................................................280 MIMO Performance .................................................................................................................. 280 MCS Performance .................................................................................................................... 282 DL MCS ..................................................................................................................................... 321 DL LAYER ................................................................................................................................. 326 DL CQI....................................................................................................................................... 327 DL PMI....................................................................................................................................... 332 DL RI ......................................................................................................................................... 334 DL ACK/NACK/DTX Ratio........................................................................................................ 336 .....................................................................................................................................338 Uplink IOT Level ....................................................................................................................... 338

19

AMC 19.1 19.2 19.3 19.4 19.5 19.6 19.7 19.8

20

IOT 20.1

SAMSUNG Electronics Co., Ltd.

page 9 of 427

2600-00FET7GAT

Ver. 6.0 TABLE OF CONTENTS

21

MLBO ..................................................................................................................................... 344 21.1 21.2 Load ...........................................................................................................................................344 Load Balancing Handover ........................................................................................................346

22

Message ................................................................................................................................. 348 22.1 22.2 22.3 22.4 Protocol Message .....................................................................................................................348 RRC Message...........................................................................................................................349 S1AP Message .........................................................................................................................354 X2AP Message .........................................................................................................................364

23

Traffic OAM ............................................................................................................................ 373 23.1 23.2 23.3 23.4 Throughput Distribution ............................................................................................................373 Delay Distribution ......................................................................................................................392 Drop Distribution .......................................................................................................................399 CQI Distribution .........................................................................................................................402 ..................................................................................................................................... 404 ACCESSIBILITY .......................................................................................................................404 RETAINABILITY .......................................................................................................................407 RETAINABILITY (QCI) .............................................................................................................408 INTEGRITY ...............................................................................................................................409 AVAILABILITY ........................................................................................................................... 411 MOBILITY .................................................................................................................................413 SUCCESS_RATE .....................................................................................................................419 Connection Drop Rate ..............................................................................................................425

24

KPI 24.1 24.2 24.3 24.4 24.5 24.6 24.7 24.8

25

UE_Category .......................................................................................................................... 426 25.1 UE Category..............................................................................................................................426

LIST OF FIGURES
Figure 1. RRC/E-RAB/S1 SIG Statistics Processing .................................................................. 37 Figure 2. Collection Time for RRC Connection Establishment .................................................... 42 Figure 3. Collection Time for RRC Connection Reconfiguration ................................................. 44 Figure 4. Collection Time for RRC Connection Reestablishment ............................................... 48 Figure 5. Collection Time for RRC Connection Release ............................................................. 53 Figure 6. Collection Time for RRC Connection Number ............................................................. 58 Figure 7. Collection Time for RRC Connection Reestablishment Time ....................................... 61 Figure 8. Collection Time for E-RAB Setup ................................................................................ 68 Figure 9. Collection Time for E-RAB Setup Add ......................................................................... 72 Figure 10. Collection Time for E-RAB Setup Time ...................................................................... 74 Figure 11. Collection Time for eNB E-RAB Erase Request......................................................... 77

SAMSUNG Electronics Co., Ltd.

page 10 of 427

2600-00FET7GAT

Ver. 6.0 TABLE OF CONTENTS

Figure 12. Collection Time for E-RAB Erase ...............................................................................79 Figure 13. Collection Time for E-RAB Modify ..............................................................................83 Figure 14. Collection Time for eNB E-RAB Erase Request .........................................................85 Figure 15. Collection Time for E-RAB Release ...........................................................................87 Figure 16. Intra eNB Handover Statistics Processing .................................................................91 Figure 17. X2-based Handover Statistics Processing .................................................................92 Figure 18. S1-based Handover Procedure .................................................................................95 Figure 19. Collection Time for Intra eNB Handover...................................................................102 Figure 20. Collection Time for X2 Handover Out .......................................................................107 Figure 21. Collection Time for X2 Handover In ......................................................................... 114 Figure 22. Collection Time for S1 Handover Out....................................................................... 118 Figure 23. Collection Time for S1 Handover In .........................................................................124 Figure 24. Collection Time for Handover Time (INTRA) ............................................................127 Figure 25. Collection Time for Handover Time (INTER S1) ......................................................128 Figure 26. Collection Time for Handover Time (INTER X2) ......................................................129 Figure 27. PS Handover Procedure from E-UTRAN to UTRAN ................................................157 Figure 28. Collection Time for Inter-RAT UTRAN PS Handover Out .........................................163 Figure 29. Collection Time for Inter-RAT UTRAN PS Handover In............................................168 Figure 30. Collection Time for CSFB PS Handover Out ............................................................176 Figure 31. Collection Time for CSFB Redirection Out ...............................................................178 Figure 32. Collection Time for UE-associated Logical S1-Connection Establishment...............250 Figure 33. Collection Time for Paging Performance ..................................................................253

SAMSUNG Electronics Co., Ltd.

page 11 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Statistics Items

SAMSUNG Electronics Co., Ltd.

page 12 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

1
1.1

Resource Management
This section provides statistics on the resource status of the system.

Resource
This section provides statistics on the CPU, memory and disk resources used by internal applications in the system. The statistics data is described below:

CPU usage: Average, maximum and minimum CPU usage in %. Memory usage: Average, maximum and minimum DRAM usage in %. Disk usage: Average, maximum and minimum disk usage in %.

Index
Name ShelfId SlotId 0~8 0~5 Range Shelf ID. The ID of the slot where the board is mounted. Description

Type
Name MemUsageAvg Unit % Description Average memory usage MemUsageMin % Minimum memory usage Y GAUGE 10 s. float 0-100 Visible Y Counter Type GAUGE Trigger Type 10 s. Data Type float Min/Max 0-100 Granularity Formula MemUsageTot/ MemUsageCnt Hourly, Daily, Monthly Formula sum (MemUsageTot)/ sum (MemUsageCnt) min (MemUsageMin)

SAMSUNG Electronics Co., Ltd.

page 13 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MemUsageMax

Unit %

Description Maximum memory usage

Visible Y

Counter Type GAUGE

Trigger Type 10 s.

Data Type float

Min/Max 0-100 -

Granularity Formula

Hourly, Daily, Monthly Formula max (MemUsageMax)

MemUsageTot

Cumulative MemUsageAvg

GAUGE

10 s

float

0~3.4*10^38

MemUsageCnt

count

MemUsage_AVG collection count

GAUGE

10 s

int

0~2147483647

CpuUsageAvg

Average CPU usage

GAUGE

10 s.

float

0-100

CpuUsageTot/ CpuUsageCnt

sum (CpuUsageTot)/ sum (CpuUsageCnt) min (CpuUsageMin) max (CpuUsageMax)

CpuUsageMin CpuUsageMax

% %

Minimum CPU usage Maximum CPU usage

Y Y

GAUGE GAUGE

10 s. 10 s.

float float

0-100 0-100

CpuUsageMaxDu ration CpuUsageTot

Maximum CPU usage time

CC

10 s.

int

0-60*Period

max (CpuUsageMaxDuration)

Cumulative CpuUsageAvg

GAUGE

10 s

float

0~3.4*10^38

CpuUsageCnt

count

CPUUsage_AVG collection count

GAUGE

10 s

int

0~2147483647

DiskUsageAvg

Average disk usage

GAUGE

10 s.

float

0-100

DiskUsageTot/ DiskUsageCnt

sum (DiskUsageTot)/ sum (DiskUsageCnt) min (DiskUsageMin) max (DiskUsageMax) -

DiskUsageMin DiskUsageMax DiskUsageTot

% % %

Minimum disk usage Maximum disk usage Cumulative DiskUsageAvg

Y Y -

GAUGE GAUGE GAUGE

10 s. 10 s. 10 s

float float float

0-100 0-100 0~3.4*10^38

SAMSUNG Electronics Co., Ltd.

page 14 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DiskUsageCnt

Unit count

Description DISKUsage_AVG collection count

Visible -

Counter Type GAUGE

Trigger Type 10 s

Data Type int

Min/Max 0~2147483647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 15 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

2
2.1

Packet Statistics
This section provides statistics on Tx/Rx packets that are processed by the system.

Ethernet Interface
This section provides details on the number of the Rx/Tx packets or bytes for each port connected to the backhaul. Collects the error Ethernet frame count, Tx/Rx link usage, Tx/Rx error rate, etc. Index
Name PortNum Range 0~3 Port number 0: BH 0 1: BH 1 2: BH 2 3: BH 3 Description

Type
Name RX_LinkUtilizati on Unit % Description Average link utilization of packets received Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0~100 Granularity Formula RX_GoodOctetSum BadOctet_TOT*8*1 00*1024*1024+((R X_UnicastPacket+R X_BroadcastPacket +RX_MulticastPack et)*20)*8*100)/(10* Hourly, Daily, Monthly Formula (sum (RX_GoodOctetSum BadOctet_TOT)*8*10 0*1024*1024+((sum (RX_UnicastPacket) +sum (RX_BroadcastPacke

SAMSUNG Electronics Co., Ltd.

page 16 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula RX_GoodOctetSum BadOctet_CNT*IfSp eed*1000000)

Hourly, Daily, Monthly Formula t)+sum (RX_MulticastPacket) )*20)*8*100)/(10*sum (RX_GoodOctetSum BadOctet_CNT)*avg (IfSpeed)*1000000)

RX_LinkUtilizati on_MAX

Maximum link utilization of packets received

GAUGE

10 s

float

0~100

max (RX_LinkUtilization_ MAX)

RX_ErrorRate

Ratio of error packets received

OW

Period

float

0~100

(RX_FifoOverrun+R X_Undersize+RX_F ragment+RX_Overs ize+RX_Jabber+RX _ErrorFrame+RX_B adCRC+RX_Collisi on+RX_LateCollisio n)*100/(RX_Unicast Packet+RX_Broadc astPacket+RX_Mult icastPacket+RX_Fif oOverrun+RX_Und ersize+RX_Fragme nt+RX_Oversize+R X_Jabber+RX_Erro rFrame+RX_BadC RC+RX_Collision+ RX_LateCollision)

(sum (RX_FifoOverrun)+ sum (RX_Undersize)+sum (RX_Fragment)+sum (RX_Oversize)+sum (RX_Jabber)+sum (RX_ErrorFrame)+su m (RX_BadCRC)+sum (RX_Collision)+sum (RX_LateCollision))*1 00/(sum (RX_UnicastPacket)+ sum (RX_BroadcastPacke t)+sum (RX_MulticastPacket)

SAMSUNG Electronics Co., Ltd.

page 17 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula +sum (RX_FifoOverrun) +sum (RX_Undersize)+sum (RX_Fragment)+sum (RX_Oversize)+sum (RX_Jabber)+sum (RX_ErrorFrame) +sum (RX_BadCRC)+sum (RX_Collision)+sum (RX_LateCollision))

RX_GoodOctet

Mbytes

Total frame length of normal packets received

CC

10 s.

int

0~2147483647

RX_UnicastPack et RX_BroadcastP acket RX_MulticastPac ket RX_FifoOverrun

count

Number of unicast packets received

CC

10 s.

int

0~2147483647

count

Number of broadcast packets received

CC

10 s.

int

0~2147483647

count

Number of multicast packets received

CC

10 s.

int

0~2147483647

count

Number of packets dropped due to insufficient buffer resources among packets received

CC

10 s.

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 18 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RX_Undersize

Unit count

Description Number of undersized packets among error packets received

Visible Y

Counter Type CC

Trigger Type 10 s.

Data Type int

Min/Max 0~2147483647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

RX_Fragment

count

Number of fragmented packets among error packets received

CC

10 s.

int

0~2147483647

RX_Oversize

count

Number of oversized packets among error packets received

CC

10 s.

int

0~2147483647

RX_Jabber

count

Number of jabber packets among error packets received

CC

10 s.

int

0~2147483647

RX_ErrorFrame

count

Number of errors received

CC

10 s.

int

0~2147483647

RX_BadCRC

count

Number of CRC error packets received

CC

10 s.

int

0~2147483647

RX_Collision

count

Number of packets received, where collision occurred

CC

10 s.

int

0~2147483647

RX_LateCollision

count

Number of packets received, where late collision occurred

CC

10 s.

int

0~2147483647

TX_LinkUtilization

Average link utilization of packets transmitted

OW

Period

float

0~100

(TX_GoodOctetSu mBadOctet_TOT*8*

(sum (TX_GoodOctetSum

SAMSUNG Electronics Co., Ltd.

page 19 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula 100*1024*1024+(T X_UnicastPacket+T X_BroadcastPacket +TX_MulticastPack et)*20)*8*100)/(10* TX_GoodOctetSum BadOctet_CNT*IfSp eed*1000000)

Hourly, Daily, Monthly Formula BadOctet_TOT)*8*10 0*1024*1024+((sum (TX_UnicastPacket)+ sum (TX_BroadcastPacke t)+sum (TX_MulticastPacket) )*20)*8*100) /(10*sum (TX_GoodOctetSum BadOctet_CNT)*avg (IfSpeed)*1000000)

TX_LinkUtilizatio n_MAX

Maximum link utilization of packets transmitted

GAUGE

10 s.

float

0~100

max (TX_LinkUtilization_ MAX)

TX_ErrorRate

Ratio of error packets transmitted

OW

Period

float

0~100

(TX_Underrun_Bad CRC+TX_Deferred +TX_E_Collisions)* 100/(TX_UnicastPa cket+TX_Broadcast Packet+TX_Multica stPacket+TX_Unde rrun_BadCRC+TX_ Deferred+TX_E_Co llisions)

(sum (TX_Underrun_BadC RC)+sum (TX_Deferred)+sum (TX_E_Collisions))*1 00/(sum (TX_UnicastPacket)+ sum (TX_BroadcastPacke t)+sum (TX_MulticastPacket) +sum

SAMSUNG Electronics Co., Ltd.

page 20 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula (TX_Underrun_BadC RC)+sum (TX_Deferred)+sum (TX_E_Collisions))

TX_GoodOctet

Mbytes

Total frame length of normal packets transmitted

CC

10 s.

int

0~2147483647

TX_UnicastPack et TX_BroadcastP acket TX_MulticastPac ket TX_Underrun_B adCRC

count

Number of unicast packets transmitted

CC

10 s.

int

0~2147483647

count

Number of broadcast packets transmitted

CC

10 s.

int

0~2147483647

count

Number of multicast packets transmitted

CC

10 s.

int

0~2147483647

count

Number of packets transmitted, where underrun or CRC error occurred

CC

10 s.

int

0~2147483647

TX_Deferred

count

Number of delayed transmissions due to media busy state when ports are open in half-duplex mode

CC

10 s.

int

0~2147483647

TX_E_Collisions

count

Number of packets whose transmission is cancelled due to excessive collision

CC

10 s.

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 21 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description when ports are open in half-duplex mode

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RX_GoodOctetS umBadOctet

Mbytes

RX GoodOctet+BadOctet

GAUGE

10 s.

int

0~2147483647

RX_GoodOctetSum BadOctet_TOT/RX_ GoodOctetSumBad Octet_CNT

sum (RX_GoodOctetSum BadOctet_TOT)/sum (RX_GoodOctetSum BadOctet_CNT)

RX_GoodOctetS umBadOctet_M AX RX_GoodOctetSu mBadOctet_TOT RX_GoodOctetS umBadOctet_C NT TX_GoodOctetS umBadOctet

Mbytes

RX_GoodOctet+BadO ctet_MAX

GAUGE

10 s.

int

0~2147483647

max (RX_GoodOctetSum BadOctet_MAX)

Mbytes

RX_GoodOctet+BadO ctet_TOT

GAUGE

10 s.

int

0~2147483647

count

RX_GoodOctet+BadO ctet_CNT

GAUGE

10 s.

int

0~2147483647

Mbytes

TX GoodOctet+BadOctet

GAUGE

10 s.

int

0~2147483647

TX_GoodOctetSum BadOctet_TOT/TX_ GoodOctetSumBad Octet_CNT

sum (TX_GoodOctetSum BadOctet_TOT)/sum (TX_GoodOctetSum BadOctet_CNT)

TX_GoodOctetS umBadOctet_M AX TX_GoodOctetSu mBadOctet_TOT

Mbytes

TX_GoodOctet+BadO ctet_MAX

GAUGE

10 s.

int

0~2147483647

max (TX_GoodOctetSum BadOctet_MAX)

Mbytes

TX_GoodOctet+BadO ctet_TOT

GAUGE

10 s.

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 22 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name TX_GoodOctetS umBadOctet_C NT IfSpeed RX_LinkUtilizati on_MIN

Unit count

Description TX_GoodOctet+BadO ctet_CNT

Visible -

Counter Type GAUGE

Trigger Type 10 s.

Data Type int

Min/Max 0~2147483647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

Mbps %

ifSpeed Minimum link utilization of packets received from the outside

OW GAUGE

10 s. 10 s

int float

0~2147483647 0~100

avg (IfSpeed) min (RX_LinkUtilization_ MIN)

TX_LinkUtilizatio n_MIN

Minimum link utilization of packets transmitted to the outside

GAUGE

10 s

float

0~100

min (TX_LinkUtilization_ MIN)

RX_GoodOctetS umBadOctet_MIN

Mbytes

RX_GoodOctet+BadO ctet_MIN

GAUGE

10 s

int

0~2147483647

min (RX_GoodOctetSum BadOctet_MIN)

TX_GoodOctetSu mBadOctet_MIN

Mbytes

TX_GoodOctet+BadO ctet_MIN

GAUGE

10 s

int

0~2147483647

min (TX_GoodOctetSum BadOctet_MIN)

SAMSUNG Electronics Co., Ltd.

page 23 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

2.2

Histogram
This section provides the number of packets per Ethernet packet size received from a backhaul port. Index
Name PortNum Range 0~3 Port number 0: BH 0 1: BH 1 2: BH 2 3: BH 3 Description

Type
Name RX_Histogram_64 Unit count Description Number of 64-byte Ethernet frames received from the Ethernet port RX_Histogram_127 count Number of 65 to 127-byte Ethernet frames received from the Ethernet port RX_Histogram_255 count Number of 128 to 255-byte Ethernet frames received from the Ethernet port RX_Histogram_511 count Number of 256 to 511-byte Ethernet frames received from the Ethernet port Y CC 10 s. int 0-2147483647 Y CC 10 s. int 0-2147483647 Y CC 10 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 10 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 24 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RX_Histogram_1023

Unit count

Description Number of 512 to 1023byte Ethernet frames received from the Ethernet port

Visible Y

Counter Type CC

Trigger Type 10 s.

Data Type int

Min/Max 0-2147483647 -

Granularity Formula

Hourly, Daily, Monthly Formula -

RX_Histogram_max

count

Number of 1024-byte Ethernet frames received from the Ethernet port

CC

10 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 25 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

2.3

Air Mac UL/DL bytes (Kbytes)


This section provides statistics for the cell throughput. Collects the average size of the transport block (TB) successfully sent/received, among the downlink/uplink TBs that the eNBs MAC allocated to the UE. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name AirMacByteUl Unit Kbytes Description The sum of the size of the MAC PDU successfully received via PUSCH during the statistics period. AirMacByteUlCnt AirMacTtiUl count TTI Collected AirMacByteUl count The sum of sections that have the MAC PDU successfully received via PUSCH during the statistics period. AirMacUlThru Kbps Average size per second of the MAC PDU successfully received via PUSCH. Y OW Period float 0-3.4*10^38 ((AirMacByt eUl*8)/(512 0*AirMacBy teUlCnt))*1 024 ((sum (AirMacByteUl)*8)/ (5120*sum (AirMacByteUlCnt)) )*1024 Y CC_LL CC 5.12 s 5.12 s. int int 0~2147483647 0~2147483647 Visible Y Counter Type CC Trigger Type 5.12 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 26 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name AirMacUlEfctivThru

Unit Kbps

Description Average size of the MAC PDU of the section successfully received via PUSCH during the statistics period.

Visible Y

Counter Type OW

Trigger Type Period

Data Type float

Min/Max 0-3.4*10^38

Granularity Formula ((AirMacByt eUl*8)/AirM acTtiUl)*10 24

Hourly, Daily, Monthly Formula ((sum (AirMacByteUl)*8)/ sum (AirMacTtiUl)) *1024 -

AirMacByteDl

Kbytes

The sum of the size of the DCCT/ DTCH MAC PDU that received HARQ ACK among the MAC PDU transmitted via PDSCH during the statistics period.

CC

5.12 s.

int

0-2147483647

AirMacByteDlCnt AirMacTtiDl

count TTI

Collected AirMacByteDl count The sum of sections that have the MAC PDU successfully transmitted via PDSCH during the statistics period.

CC_LL CC

5.12 s 5.12 s.

int int

0~2147483647 0-2147483647

AirMacDlThru

Kbps

Average size per second of the DCCT/DTCH MAC PDU that received HARQ ACK among the MAC PDU transmitted via PDSCH during the statistics period.

OW

Period

float

0-3.4*10^38

((AirMacByt eDl*8)/(512 0*AirMacBy teDlCnt))*1 024

((sum (AirMacByteDl)*8)/ (5120*sum (AirMacByteDlCnt)) )*1024

AirMacDlEfctivThru

Kbps

Average size of the MAC PDU of the section successfully transmitted via PDSCH during the statistics period

OW

Period

float

0-3.4*10^38

((AirMacByt eDl*8)/AirM acTtiDl)*10 24

((sum (AirMacByteDl)*8)/ sum (AirMacTtiDl)) *1024 -

AirMacByteUlCurr ent

Kbytes

The most recently collected AirMacByteUl value

CC_LL

5.12 s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 27 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name AirMacByteDlCurr ent AirMacUlThruMin

Unit Kbytes

Description The most recently collected AirMacByteDl value

Visible -

Counter Type CC_LL

Trigger Type 5.12 s

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Kbps

Minimum of the average size per second of the MAC PDU successfully received via PUSCH

OW

5.12 s.

float

0-3.4*10^38

min (AirMacUlThruMin)

AirMacUlThruMax

Kbps

Maximum of the average size per second of the MAC PDU successfully received via PUSCH

OW

5.12 s.

float

0-3.4*10^38

max (AirMacUlThruMax)

AirMacDlThruMin

Kbps

Minimum of the average size per second of the DCCT/DTCH MAC PDU that received HARQ ACK among the MAC PDU transmitted via PDSCH during the statistics period

OW

5.12 s.

float

0-3.4*10^38

min (AirMacDlThruMin)

AirMacDlThruMax

Kbps

Maximum of the average size per second of the DCCT/DTCH MAC PDU that received HARQ ACK among the MAC PDU transmitted via PDSCH during the statistics period

OW

5.12 s.

float

0-3.4*10^38

max (AirMacDlThruMax)

Collection Time TTI (Transmission Time Interval: 1 ms)

SAMSUNG Electronics Co., Ltd.

page 28 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

2.4

Air RLC UL/DL bytes


This section provides statistics for the downlinks transmitted byte and retransmitted byte count/throughput/IP throughput and the uplink s transmitted byte count/throughput for the wireless section of the eNB. Since they are collected and summed for each cell and each QCI, they are collected after cell setup has finished. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name AirRlcByteUl Unit Kbytes Description Air RLC uplink bytes Number of bytes transmitted at the RLC as air uplink. Collects the number of data bytes received by the UE for each cell and QCI. AirRlcByteDl Kbytes Air RLC downlink bytes Number of bytes transmitted at the RLC as air downlink. Collects the Y CC 10 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 10 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 29 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description number of data bytes transmitted to the UE for each cell and QCI.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

AirRlcByteDlRe

Kbytes

Air RLC downlink ReTx bytes Number of bytes retransmitted at the RLC as air downlink. Collects the number of data bytes transmitted to the UE for each cell and QCI.

CC

10 s.

int

0-2147483647

AirUlThru

Kbps

Air uplink throughput Collects the data received from the UE as the air uplink throughput for each cell and QCI.

OW

10 s.

float

0-3.4*10^38

(AirRlcByte Ul*1024*8)/ (10*RlcAirB yteUlCnt*10 00)

(sum (AirRlcByteUl)*102 4*8)/(10*sum (RlcAirByteUlCnt)* 1000) -

AirUlThruTot

Kbps

The sum of collected AirUlThru

OW

10 s

float

0~3.4*10^38

AirUlThruCnt AirDlThru

count Kbps

Collected AirUlThru count Air downlink throughput Collects the data transmitted to the UE as the air downlink throughput for each cell and QCI. Y

OW OW

10 s 10 s.

int float

0~2147483647 0-3.4*10^38

(AirRlcByte Dl*1024*8)/ (10*RlcAirB yteDlCnt*10 00)

(sum (AirRlcByteDl)*102 4*8)/(10*sum (RlcAirByteDlCnt)* 1000)

AirDlThruTot

Kbps

The sum of collected

OW

10 s

float

0~3.4*10^38

SAMSUNG Electronics Co., Ltd.

page 30 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description AirDlThru

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

AirDlThruCnt IpThru

count Kbps

Collected AirDlThru count IP throughput Collects the IP throughput for each cell and QCI using the method specified in 3GPP TS 32.450. Y

OW SI

10 s 10 s.

int float

0~2147483647 0-3.4*10^38

IpThruTot/Ip ThruCn

sum (IpThruTot)/ sum (IpThruCnt)

IpThruTot

Kbps

The sum of collected IpThru

SI

10 s

float

0~3.4*10^38

IpThruCnt RlcAirByteUlCurrent

count Kbytes

Collected IpThru count The most recently collected RlcAirByteUl

SI CC

10 s 10 s

int int

0~2147483647 0~2147483647

RlcAirByteDlCurrent

Kbytes

The most recently collected RlcAirByteDl

CC

10 s

int

0~2147483647

RlcAirByteUlCnt

count

RlcAirByteUl collection count

CC

10 s

int

0~2147483647

RlcAirByteDlCnt

count

RlcAirByteDl collection count

CC

10 s

int

0~2147483647

AirUlThruMin

Kbps

Air uplink throughput Min

OW

10 s.

float

0-3.4*10^38

min (AirUlThruMin)

AirUlThruMax

Kbps

Maximum air uplink throughput

OW

10 s.

float

0-3.4*10^38

max (AirUlThruMax)

AirDlThruMin

Kbps

Minimum air downlink throughput

OW

10 s.

float

0-3.4*10^38

min (AirDlThruMin)

SAMSUNG Electronics Co., Ltd.

page 31 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name AirDlThruMax

Unit Kbps

Description Maximum air downlink throughput

Visible Y

Counter Type OW

Trigger Type 10 s.

Data Type float

Min/Max 0-3.4*10^38

Granularity Formula -

Hourly, Daily, Monthly Formula max (AirDlThruMax)

IpThruMin IpThruMax

Kbps Kbps

Minimum IP throughput Maximum IP throughput

Y Y

OW OW

10 s. 10 s.

float float

0-3.4*10^38 0-3.4*10^38

min (IpThruMin) max (IpThruMax)

SAMSUNG Electronics Co., Ltd.

page 32 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

2.5

S-GW UL/DL packets


This section provides statistics for bytes, packet counts and throughput of user data transmitted and received between the eNB and S-G W, which are collected per QCI according to the 3GPP standard (TS32.425 Performance Measurements). Each item is collected by the PDCP layer within the eNB. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name ByteUleNBQCI Unit Kbytes Description Total bytes of user data transmitted from the eNB to the S-GW. ThruUleNBQCI Kbps (Total bits of user data transmitted to the S-GW)/(Total time when user data were transmitted) Y GAUGE 2 s. float 0-3.4*10^38 (ByteUleNBQ CI*1024*8)/(2 *ByteUleNBQ CICnt)/1000 (sum (ByteUleNBQCI)*1 024*8)/(2*sum (ByteUleNBQCICnt ))/1000 ThruUleNBQCIM ax Kbps Maximum value over a fiveminute period of (Total bits of user data transmitted to the SY GAUGE 2 s. float 0-3.4*10^38 max (ThruUleNBQCIMa x) Visible Y Counter Type CC Trigger Type 2 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 33 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description GW)/(Total time when user data were transmitted).

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ThruUleNBQCITot

Kbps

The sum of collected ByteUleNBQCI

GAUGE

2s

float

0~3.4*10^38

ThruUleNBQCIC nt PacketCntUl

count

Collected ByteUleNBQCI count

GAUGE

2s

int

0~214748364 7

count

Total number of packets transmitted from the eNB to the S-GW

CC

2 s.

int

0-2147483647

ByteDleNBQCI

Kbytes

Total bytes of user data the eNB received from the S-GW.

CC

2 s.

int

0-2147483647

ThruDleNBQCI

Kbps

(Total bits of user data received from the S-GW)/(Total time when user data were received)

GAUGE

2 s.

float

0-3.4*10^38

(ByteDleNBQ CI*1024*8)/(2 *ByteDleNBQ CICnt)/1000

(sum (ByteDleNBQCI)*1 024*8)/(2*sum (ByteDleNBQCICnt ))/1000

ThruDleNBQCIM ax

Kbps

Maximum value over a fiveminute period of (Total bits of user data transmitted to the SGW)/(Total time when user data were transmitted)

GAUGE

2 s.

float

0-3.4*10^38

max (ThruDleNBQCIMa x)

ThruDleNBQCITot

Kbps

The sum of collected ThruDleNBQCI

GAUGE

2s

float

0~3.4*10^38

ThruDleNBQCIC nt

count

Collected ThruDleNBQCI count

GAUGE

2s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 34 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PacketCntDl

Unit count

Description Total number of packets the eNB received from the S-GW

Visible Y

Counter Type CC

Trigger Type 2 s.

Data Type int

Min/Max 0-2147483647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

ByteUleNBQCICnt

count

Collection count of the total bytes of user data transmitted from the eNB to the S-GW.

CC

2 s.

int

0-2147483647

ByteDleNBQCICnt

count

Collection count of the total bytes of user data the eNB received from the S-GW.

CC

2 s.

int

0-2147483647

ThruUleNBQCIMin

Kbps

Minimum value over a fiveminute period of (Total bits of user data transmitted to the SGW)/(Total time when user data were transmitted)

GAUGE

2 s.

float

0-3.4*10^38

min (ThruUleNBQCIMin)

ThruDleNBQCIMin

Kbps

Minimum value over a fiveminute period of (Total bits of user data transmitted to the SGW)/(Total time when user data were transmitted)

GAUGE

2 s.

float

0-3.4*10^38

min (ThruDleNBQCIMin)

SAMSUNG Electronics Co., Ltd.

page 35 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

2.6

VPN Interface
This section provides statistics for IPSec Tunnel. Index
Name VPNNum Range 0~5 Description VPN Number

Type
Name VPN_RxOctet VPN_RxPacket VPN_RxDropPacket Unit Mbyte count count Description Rx octet count for IPSec tunnel. Rx packet count for IPSec tunnel. Rx drop packet count for IPSec tunnel. VPN_TxOctet VPN_TxPacket VPN_TxDropPacket Mbyte count count Tx octet count for IPSec tunnel. Tx packet count for IPSec tunnel. Tx drop packet count for IPSec tunnel. Y Y Y CC_LL CC CC 10 s 10 s 10 s int int int 0~2147483647 0~2147483647 0~2147483647 Visible Y Y Y Counter Type CC_LL CC CC Trigger Type 10 s 10 s 10 s Data Type int int int Min/Max 0~2147483647 0~2147483647 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 36 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

RRC
The following shows the statistical definition and message flow for each stage of th e Idle to Active (Service Request) procedure by the UE, which allows to identify t he overall handling of the RRC/E-RAB/S1 SIG statistics.

EPC UE eNB MME S-GW

1) 2)

Random Access procedure RRCConnectionRequest RRCConnectionSetup [1] RRC establishment 5) INITIAL UE MESSAGE
(SERVICE REQUEST)

3) 4)

RRCConnectionSetupComplete
(SERVICE REQUEST)

6) Authentication/NAS security setup

[2] S1SIG setup

7) INITIAL CONTEXT SETUP REQUEST


(SERVICE ACCEPT)

8) SecurityModeCommand 9) SecurityModeComplete 10) RRCConnectionReconfiguration


(SERVICE ACCEPT)

[3] E-RAB establishment

11) RRCConnectionReconfiguration Complete

Uplink data

Uplink data

12) INITIAL CONTEXT SETUP RESPONSE 13) Modify Bearer Request 14) Modify Bearer Response
Downlink data Downlink data

Figure 1. RRC/E-RAB/S1 SIG Statistics Processing

SAMSUNG Electronics Co., Ltd.

page 37 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Step 1) 2)-4)

Description The UE performs the Random Access procedure with the eNB. The UE transmits the NAS SERVICE REQUEST message to the MME. The SERVICE REQUEST message is encapsulated in an RRC message transmitted to the eNB.

5)

The eNB transmits the SERVICE REQUEST message to the MME. The SERVICE REQUEST is encapsulated in an S1-AP INITIAL UE message.

6)

If there is no UE context for the UE in the network, the integrity is not protected for the ATTACH REQUEST message, or the integrity check fails, an authentication and an NAS security setup are always performed. The UE performs the EPS AKA procedure (TS 33.401, 6.1.1) with the MME. The MME sets up an NAS security association with the UE using the NAS SMC procedure (TS 33.401, 7.2.4.4).

7)

The MME transmits the S1-AP Initial Context Setup Request message to the eNB. This step activates both the radio bearer and S1 bearer for all active EPS bearers.

8)-11)

The eNB sets up the RRC radio bearers. The user plane security is set up at this step. The uplink data from the UE can be sent to the S-GW by the S-GW. The eNB transmits the uplink data to the S-GW, and then the S-GW transmits it to the P-GW.

12) 13)-14)

The eNB transmits the S1-AP Initial Context Setup Request message to the MME. The MME transmits the Modify Bearer Request message for each PDN connection to the S-GW. Now, the S-GW can transmit the downlink data to the UE. The S-GW transmits the Modify Bearer Response message to the MME.

SAMSUNG Electronics Co., Ltd.

page 38 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.1

RRC Connection Establishments


This section provides access statistics between RRC connection request and RRC connection setup complete are collected for each cell. The access call is identified by the establishment cause within the RRC connection request message initially informed by the UE. Index
Name cNum mcID EstabCause 0~2 0~0 0~5 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: relocated: Access by the UE due to handover Description

Type
Name ConnEstabAtt Unit count Description The attempt count for RRC ESTAB ConnEstabSucc ConnEstabFail_CP _CC_TO count count RRC ESTAB success count. A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) Y Y CC CC event event int int 0-2147483647 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 39 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description during RRC establishment.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ConnEstabFail_CP _CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB during RRC establishment.

CC

event

int

0-2147483647

ConnEstabFail_UP _MAC_FAIL

count

A call is released due to the failure in the MAC block during RRC establishment.

CC

event

int

0-2147483647

ConnEstabFail_UP _PDCP_FAIL

count

A call is released due to the failure in the PDCP block during RRC establishment.

CC

event

int

0-2147483647

ConnEstabFail_UP _RLC_FAIL

count

A call is released due to the failure in the RLC block during RRC establishment.

CC

event

int

0-2147483647

ConnEstabFail_RR C_SIG_TO

count

A call is released due to RRC uplink message timeout (not received) during RRC establishment.

CC

event

int

0-2147483647

ConnEstabFail_S1A P_LINK_FAIL

count

A call is released due to S1 SCTP link failure during RRC establishment.

CC

event

int

0-2147483647

ConnEstabFail_S1A P_SIG_FAIL

count

A call is released due to receiving S1AP signaling during RRC establishment.

CC

event

int

0-2147483647

ConnEstabReject_C

count

A call cannot be accepted

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 40 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name P_CC_FAIL

Unit

Description because the cell is barred after receiving the RRC Connection Request message, or there is no MME available for service during RRC establishment.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ConnEstabReject_C P_CAPA_CAC_FAI L

count

A call cannot be accepted due to Call Admission Control after receiving the RRC Connection Request message during RRC establishment.

CC

event

int

0-2147483647

ConnEstabReject_S 1AP_MME_OVLD

count

A call cannot be accepted due to MME overload during RRC establishment.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 41 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB MME S/GW

RRC_IDLE Random Access Preamble Random Access Response Rrc Connection Request Rrc Connection Setup Rrc Connection Setup Complete 1 Attempt

Success Initial UE Message

RRC_CONNECTED

Figure 2. Collection Time for RRC Connection Establishment

For statistics on RRC connection establishment, Attempt, Success, Fail and Reject statistics are counted. The Attempt statistic is counte d when the RRC Connection Request message is received. Success statistic is counted when the messages up to RRC Connection Setu p Complete are successfully received. When a timeout or internal failure occurs during the procedure from 1 to 2, as indicated in the figure above, it is counted as Fail, ret urning the cause value. Reject statistic is counted when the eNB determines that the call cannot be accepted after receiving the RRC Connection Request message, and the applicable cause value is recorded.

SAMSUNG Electronics Co., Ltd.

page 42 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.2

RRC Connection Reconfiguration


This section provides statistics for RRC Connection Reconfigurations count. There is no Fail statistic as the RRC Connection Reconfig uration message is transmitted down from the Serving eNB and the RRC Connection Reconfiguration Complete message is transmitted to the Target eNB. In this case, the attempt and success counts in the reconfiguration statistics for the system can be different. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name ConnReconfigAtt Unit count Description RRC Connection Reconfiguration attempt count. ConnReconfigSu cc count RRC Connection Reconfiguration success count. Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 43 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE MME S/GW

Rrc Connection Reconfiguration

Attempt

Rrc Connection Reconfiguration Complete 2 Success

RRC_CONNECTED

Figure 3. Collection Time for RRC Connection Reconfiguration

The transmission of the RRC Connection Reconfiguration to the UE is counted as Attempt, while the receipt of RRC Connection Reco nfiguration Complete from the UE is counted as Success. Upon handover, the source eNB transmits RRC Connection Reconfiguration (handover command) to the UE; the UE transmits RRC Connection Reconfiguration Complete (handover command complete) to the tar get eNB. Therefore, a fail count is not returned because it is not possible to determine transmission failure.

SAMSUNG Electronics Co., Ltd.

page 44 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.3

RRC Connection Reestablishment


As shown below, when a RRC Reestablishment cause occurs with the UE in RRC connected state, statistics on the RRC connection R eestablishment are collected for each cell. Index
Name cNum mcID ReEstabCause 0~2 0~0 0~3 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Reestablishment Cause - 0 (reconfigurationFailure): Reestablishment occurs due to reconfiguration failure - 1 (handoverFailure): Reestablishment occurs due to handover failure - 2 (otherFailure): Reestablishment occurs due to other failures - 3: reserved Description

Type
Name ConnReEstabAtt Unit count Description The attempt count for RRC_REESTAB ConnReEstabSucc count The success count for RRC_REESTAB ConnReEstabFail_CP _CC_FAIL count A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB during Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Collection Time event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 45 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description RRC Reestablishment.

Visible

Counter Type

Collection Time

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ConnReEstabFail_UP _MAC_FAIL

count

A call is released due to the failure in the MAC block during RRC Reestablishment.

CC

event

int

0-2147483647

ConnReEstabFail_UP _PDCP_FAIL

count

A call is released due to the failure in the PDCP block during RRC Reestablishment.

CC

event

int

0-2147483647

ConnReEstabFail_UP _RLC_FAIL

count

A call is released due to the failure in the RLC block during RRC Reestablishment.

CC

event

int

0-2147483647

ConnReEstabFail_RR C_SIG_TO

count

A call is released due to RRC uplink message timeout (not received) during RRC Reestablishment.

CC

event

int

0-2147483647

ConnReEstabFail_S1 AP_LINK_FAIL

count

A call is released due to receiving S1AP signaling during RRC Reestablishment.

CC

event

int

0-2147483647

ConnReEstabFail_S1 AP_SIG_FAIL

count

A call is released due to S1AP signaling timeout (not received) during RRC Reestablishment.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 46 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ConnReEstabReject_ CP_CC_FAIL

Unit count

Description A call cannot be accepted because the cell is barred after receiving the RRC Connection Request message, or there is no MME available for service during RRC Reestablishment.

Visible Y

Counter Type CC

Collection Time event

Data Type int

Min/Max 0-2147483647 -

Granularity Formula

Hourly, Daily, Monthly Formula -

ConnReEstabReject_ CP_CAPA_CAC_FAIL

count

A call cannot be accepted due to Call Admission Control after receiving the RRC Connection Request message during RRC Reestablishment.

CC

event

int

0-2147483647

ConnReEstabReject_ CP_QOS_CAC_FAIL

count

A call cannot be accepted due to insufficient QoSbased eNB resources during RRC Reestablishment.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 47 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE Rrc Connection Reestablishment Request MME S/GW

Attempt

Rrc Connection Reestablishment

Rrc Connection Reestablishment Complete

2 Success

RRC_CONNECTED

Figure 4. Collection Time for RRC Connection Reestablishment

When RRC Connection Reestablishment Request is received, it is counted as an attempt; if the call context exists in the eNB and the security key value uploaded by the UE matches, RRC Connection Reestablishment is transmitted to the UE; and when RRC Connectio n Reestablishment Complete is received, it is counted as Success. If a call text does not exist in the eNB or the security key value u ploaded by the UE does not match, RRC Connection Reestablishment Reject is transmitted to the UE, and it is counted as Reject. The n, if RRC Connection Reestablishment Complete is not received, the call is released.

SAMSUNG Electronics Co., Ltd.

page 48 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.4

RRC Connection Release


This section provides statistics data for RRC Connection Release. MME-initiated RRC connection release: The MME transmits the UE context release command to eNB to release the UE-associated logi cal connection. Then, the eNB transmits the RRC connection release to the UE, releases the eNB resource, and transmits the UE conte xt release complete to the MME to complete the call release procedure. An MME-initiated call release occurs in the following cases.
Case Number 1 2 3 4 A procedure between UE and MME is completed (e.g. Detach). A call in the source eNB is released due to successful handover. A call in the target eNB is released due to cancelled handover. The old logical connection is to be released when 2 logical connections are established for a specific UE (e.g. when UE duplication occurs in the MME). 5 The UE is not a CSG member of the CSL cell. Description

eNB-initiated RRC connection release: If the eNB MAC scheduler determines that the UE has no traffic for the specific period of time, it transmits the UE context release request to the MME. Then the call release procedure is completed by an MME-initiated RRC con nection release procedure. A call may be released by transmitting the UE context release request to the MME upon eNB failure or call setup failure. An eNB-initiated call release occurs in the following cases.
Case Number 1 2 3 A call is released by user inactivity. A call is released by eNB Radio Link Fail (RLF). A call is released by MAX retransmission at the RCL end. Description

SAMSUNG Electronics Co., Ltd.

page 49 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name ConnRelease_CP_ CC_NORMAL ConnRelease_CP_ CC_TO count Unit count Description A call is released in eNB upon RRC release. A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during RRC release. ConnRelease_CP_ CC_FAIL count A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB during RRC release. ConnRelease_UP_ GTP_FAIL count A call is released due to the failure in the GTP block during RRC release. ConnRelease_UP_ MAC_FAIL count A call is released due to the failure in the MAC block during RRC release. ConnRelease_UP_ MAC_UE_INACT count A call is released due to UE inactivity in the eNB during RRC Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 50 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit release.

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ConnRelease_UP_P DCP_FAIL

count

A call is released due to the failure in the PDCP block during RRC release.

CC

event

int

0-2147483647

ConnRelease_UP_ RLC_FAIL

count

A call is released due to the failure in the RLC block during RRC release.

CC

event

int

0-2147483647

ConnRelease_RRC _HC_TO

count

A call is released due to HO command timeout (not received) during RRC release.

CC

event

int

0-2147483647

ConnRelease_RRC _SIG_FAIL

count

A call is released due to receiving RRC signaling during RRC release.

CC

event

int

0-2147483647

ConnRelease_RRC _SIG_TO

count

A call is released due to RRC uplink message timeout (not received) during RRC release.

CC

event

int

0-2147483647

ConnRelease_CP_B H_CAC_FAIL

count

A call is released due to insufficient backhaul-based eNB resources during RRC release.

CC

event

int

0-2147483647

ConnRelease_CP_ CAPA_CAC_FAIL

count

A call is released due to insufficient capacity-based eNB resources during RRC release.

CC

event

int

0-2147483647

ConnRelease_CP_ QOS_CAC_FAIL

count

A call is released due to insufficient QoS-based eNB resources during RRC release.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 51 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ConnRelease_S1AP _CU_FAIL

Unit count

Description A call is released due to the S1AP specification cause during RRC release.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ConnRelease_S1AP _LINK_FAIL ConnRelease_S1AP _RO_TO

count

A call is released due to S1 SCTP link failure during RRC release.

CC

event

int

0-2147483647

count

A call is released due to S1AP relocoverall timeout (not received) during RRC release.

CC

event

int

0-2147483647

ConnRelease_S1AP _SIG_FAIL

count

A call is released due to receiving S1AP signaling during RRC release.

CC

event

int

0-2147483647

ConnRelease_S1AP _SIG_TO

count

A call is released due to S1AP signaling timeout (not received) during RRC release.

CC

event

int

0-2147483647

ConnRelease_X2AP _CU_FAIL

count

A call is released due to the X2AP specification cause during RRC release.

CC

event

int

0-2147483647

ConnRelease_X2AP _LINK_FAIL ConnRelease_X2AP _RO_TO

count

A call is released due to X2 SCTP link failure during RRC release.

CC

event

int

0-2147483647

count

A call is released due to X2AP RelocOverall timeout (not received) during RRC release.

CC

event

int

0-2147483647

ConnRelease_X2AP _SIG_FAIL

count

A call is released due to X2AP signaling received during RRC release.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 52 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE MME S/GW

Rrc Connection Release

Count

RRC_CONNECTED

Figure 5. Collection Time for RRC Connection Release

Call statistics are released when RRC connection is released. Since RRC connection release cause is returned, it is possible to determin e call release cause.

SAMSUNG Electronics Co., Ltd.

page 53 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.5

RRC Connection number


This section provides statistics data for the average RRC connection count per unit time and the maximum RRC connection count for each cell. The RRC connection count is collected every 2 seconds, and the statistics block calculates the average, maximum and total values per minute using the collected data Index
Name cNum Range 0~2 Description Cell Index

Type
Name ConnNo Unit count Description Average RRC connection per unit time ConnMax count Maximum RRC connection per unit time ConnTot ConnCnt ReleaseCallHoldin gTime count count s Sum of ConnNo collected Collected ConnNo count Average Release Call Holding Time during which the RRC connection was maintained which is calculated based on call release. Y Y GAUGE GAUGE SI 2 s. 2s event float int float 0-3.4*10^38 0~2147483647 0-60*Period ReleaseCall ot/ReleaseCa llCnt sum (ReleaseCall (ReleaseCallCnt) Y GAUGE 2 s. float 0-3.4*10^38 Visible Y Counter Type GAUGE Trigger Type 2 s. Data Type float Min/Max 0-3.4*10^38 Granularity Formula ConnTot/Con nCnt Hourly, Daily, Monthly Formula sum (ConnTot)/sum (ConnCnt) max (ConnMax)

HoldingTimeT HoldingTimeTot)/sum

SAMSUNG Electronics Co., Ltd.

page 54 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ReleaseCallHoldin gTimeTot ReleaseCallCnt

Unit s

Description Total RRC Connection Release Call Holding Time

Visible Y

Counter Type SI

Trigger Type event

Data Type float

Min/Max 0-60*Period -

Granularity Formula

Hourly, Daily, Monthly Formula -

count

Call Release Count

SI

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 55 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.6

RRC Connection Setup Time


This section provides statistics data for the average and maximum RRC Connection Setup times. Index
Name cNum mcID EstabCause 0~2 0~0 0~5 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: relocated: Access by the UE due to handover Description

Type
Name ConnEstabTime Unit ms Description Average RRC connection setup time Visible Y Counter Type GAUGE Collection Time event Data Type float Min/Max 0-60* Period*10 00 Granularity Formula ConnEstabTimeTot/C onnEstabTimeCnt Hourly, Daily, Monthly Formula sum (ConnEstabTimeTot)/ sum (ConnEstabTimeCnt) ConnEstabTimeMax ms Maximum RRC connection setup time Y GAUGE event float 0-60* Period*10 00 max (ConnEstabTimeMax)

SAMSUNG Electronics Co., Ltd.

page 56 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ConnEstabTimeTot

Unit ms

Description Sum of ConnEstabTime collected

Visible Y

Counter Type GAUGE

Collection Time event

Data Type float

Min/Max 03.4*10^38

Granularity Formula -

Hourly, Daily, Monthly Formula

ConnEstabTimeCnt

count

Collected ConnEstabTime count

GAUGE

event

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 57 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE MME S/GW

Rrc Connection Request Rrc Connection Setup Rrc Connection Setup Complete Initial UE Message RRC_CONNECTED

RRC Connection Setup time

Figure 6. Collection Time for RRC Connection Number

The RRC Connection setup time is a time taken from receiving the RRC Connection Request message up to receiving the RRC Conne ction Setup Complete message. The eNB calculates and reports to the LSM the average and maximum values for the collection period (in milliseconds).

SAMSUNG Electronics Co., Ltd.

page 58 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.7

RRC Connection Reestablishment Time


This section provides statistics data for the average and maximum RRC Connection Reestablishment Setup times. The cause is identified by the RRC connection Reestablishment cause informed by the UE. Index
Name cNum mcID ReEstabCause 0~2 0~0 0~3 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Reestablishment Cause 0: reconfigurationFailure: Reestablishment occurs due to reconfiguration failure 1: handoverFailure: Reestablishment occurs due to handover failure 2: otherFailure: Reestablishment occurs due to other failures 3: reserved Description

Type
Name ConnReEstab Time Unit ms Description Average RRC connection reestablishment setup time Maximum RRC connection reestablishment setup time Visible Y Counter Type GAUGE Trigger Type event Data Type float Min/Max 0~60*Period*100 0 Granularity Formula ConnReEstabT imeTot/ConnRe EstabTimeCnt Hourly, Daily, Monthly Formula sum (ConnReEstabTimeTot)/ sum (ConnReEstabTimeCnt) max (ConnReEstabTimeMax)

ConnReEstab TimeMax

ms

GAUGE

event

float

0~60*Period*100 0

SAMSUNG Electronics Co., Ltd.

page 59 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ConnReEstab TimeTot ConnReEstab TimeCnt

Unit ms

Description Sum of ConnReEstabTime collected Collected ConnReEstabTime count

Visible Y

Counter Type GAUGE

Trigger Type event

Data Type float

Min/Max 0~3.4*10^38 -

Granularity Formula -

Hourly, Daily, Monthly Formula

count

GAUGE

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 60 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE MME S/GW

Rrc Connection Reestablishment Request Rrc Connection Reestablishment

RRC Connection Resetup time

Rrc Connection Reestablishment Complete

RRC_CONNECTED

Figure 7. Collection Time for RRC Connection Reestablishment Time

The RRC Connection setup time is a time taken from receiving the RRC Connection Request message up to receive in the RRC Conn ection Setup Complete message. The eNB calculates and reports to the LSM the average and maximum values for the collection period (in milliseconds).

SAMSUNG Electronics Co., Ltd.

page 61 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

3.8

Call Drop
Call drop statistics are calculated for successfully connected calls but abnormally dropped due to eNB failure or by the MME. They are identified by the RRC connection establishment cause informed by the UE. Successful call connection indicates that the defau lt bearer setup is successful or incoming handover is successful for a call. Calls released by the eNB due to user inactivity, normally r eleased by the MME, and released by the UE duplication are not considered abnormally terminated. Index
Name cNum mcID EstabCause Range 0~2 0~0 0~5 Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: relocated: Access by the UE due to handover Description

SAMSUNG Electronics Co., Ltd.

page 62 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Type
Name CallDrop_ECCB_DSP_ AUDIT_RLC_MAC_CA LL_RELEASE Unit count Description A call is released due to the resource mismatch, because the ECCB has remaining calls but the RLC and the MAC have no call remaining. CallDrop_ECCB_RCV_ RESET_REQUEST_F ROM_ECMB count A call is released due to receiving a reset request from the ECMB block due to refork of a specific block in eNB. CallDrop_ECCB_RCV_ CELL_RELEASE_IND_ FROM_ECMB count A call is released due to the Cell Release Ind message received from the ECMB block because of DSP down or CPRI failure caused by DSP problem. CallDrop_ECCB_RADI O_LINK_FAILURE CallDrop_ECCB_DSP_ AUDIT_MAC_CALL_R ELEASE count count A call is released due to radio link fail. A call is released due to the resource mismatch, because the ECCB and the RLC have remaining calls but the MAC has no call remaining. CallDrop_ECCB_ARQ_ MAX_RE_TRANSMISS ION count A call is released when ARQ ACK is not received from the UE after the RLC performs Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 63 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description transmission as many as the Max Retransmission to the UE.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

CallDrop_ECCB_DSP_ AUDIT_RLC_CALL_RE LEASE

count

A call is released due to the resource mismatch, because the ECCB and the MAC have remaining calls but the RLC has no call remaining.

CC

event

int

0-2147483647

CallDrop_ECCB_TMO UT_rrcConnectionReco nfig

count

A call is released when the RRC Connection Reconfiguration Complete message is not received from the UE after transmitting the RRC Connection Reconfiguration message.

CC

event

int

0-2147483647

CallDrop_ECCB_TMO UT_rrcConnectionReEs tablish

count

A call is released when the RRC Connection Reestablishment Complete message is not received from the UE after transmitting the RRC Connection Reestablishment message to the UE.

CC

event

int

0-2147483647

CallDrop_ECCB_S1_S CTP_OUT_OF_SERVI CE

count

A call is released when the S1 Associations status is changed from In Service to Out of Service state.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 64 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4
4.1

ERAB
E-RAB Setup
This section provides statistics data for the default bearer setup to activate the initial DRBs radio and S1 bearer. Index
Name cNum mcID EstabCause 0~2 0~0 0~5 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: relocated: Access by the UE due to handover QCI 0~255 QoS Class Identifier Description

Type
Name EstabInitAttNbr EstabInitSuccNbr ErabInitFailNbr_CP _CC_TO Unit count count count Description ERAB setup attempt count. ERAB setup success count. A call is released due to call control timeout in the protocol Visible Y Y Y Counter Type CC CC CC Trigger Type event event event Data Type int int int Min/Max 0-2147483647 0-2147483647 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 65 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description blocks (MAC, RLC, PDCP, GTP) during ERAB setup.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ErabInitFailNbr_CP _CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_UP _GTP_FAIL

count

A call is released due to the failure in the GTP block during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_UP _MAC_FAIL

count

A call is released due to the failure in the MAC block during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_UP _PDCP_FAIL

count

A call is released due to the failure in the PDCP block during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_UP _RLC_FAIL

count

A call is released due to the failure in the RLC block during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_RR C_SIG_FAIL

count

A call is released due to receiving RRC signaling during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_RR C_SIG_TO

count

A call is released due to ERAB uplink message timeout (not received) during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_CP

count

A call is released due to

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 66 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name _BH_CAC_FAIL

Unit

Description insufficient backhaul-based eNB resources during ERAB setup.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ErabInitFailNbr_CP _CAPA_CAC_FAIL

count

A call is released due to insufficient capacity-based eNB resources during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_CP _QOS_CAC_FAIL

count

A call is released due to insufficient QoS-based eNB resources during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_S1 AP_CU_FAIL

count

A call is released due to the S1AP specification cause during ERAB setup.

CC

event

int

0-2147483647

ErabInitFailNbr_S1 AP_LINK_FAIL

count

A call is released due to S1 SCTP link failure during ERAB setup

CC

event

int

0-2147483647

ErabInitFailNbr_S1 AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during ERAB setup.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 67 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_CONNECTED Authentication Procedure (NAS) Initial Context Setup Request Security Mode Command Security Mode Complete Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete Initial Context Setup Response RRC_CONNECTED 2 Success 1 Attempt MME S/GW

Figure 8. Collection Time for E-RAB Setup

For E-RAB setup count statistics, Attempt is counted when the Initial Context Setup Request message is received during the initial call setup. Success is counted when the Initial Context Setup Response message is transmitted. A failure is counted when a timeout or fai lure occurs during the procedure and the applicable cause value is recorded.

SAMSUNG Electronics Co., Ltd.

page 68 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.2

E-RAB Setup Add


This section provides statistics data for the number of additional E-RAB (dedicated bearer) setups by the MME following the initial de fault bearer setup. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name EstabAddAttNbr Unit count Description The number of attempts for additional ERAB setup EstabAddSuccNbr count The number of successes for additional ERAB setup ErabAddFailNbr_CP _CC_TO count A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during additional ERAB setup. ErabAddFailNbr_CP _CC_FAIL count A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB during additional ERAB setup. Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 69 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ErabAddFailNbr_UP _GTP_FAIL

Unit count

Description A call is released due to the failure in the GTP block during additional ERAB setup.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ErabAddFailNbr_UP _MAC_FAIL

count

A call is released due to the failure in the MAC block during additional ERAB setup.

CC

event

int

0-214743647

ErabAddFailNbr_UP _PDCP_FAIL

count

A call is released due to the failure in the PDCP block during additional ERAB setup.

CC

event

int

0-2147483647

ErabAddFailNbr_UP _RLC_FAIL

count

A call is released due to the failure in the RLC block during additional ERAB setup.

CC

event

int

0-2147483647

ErabAddFailNbr_RR C_SIG_FAIL

count

A call is released due to receiving RRC signaling during additional ERAB setup.

CC

event

int

0-2147483647

ErabAddFailNbr_RR C_SIG_TO

count

A call is released due to ERAB uplink message timeout (not received) during additional RRC setup

CC

event

int

0-2147483647

ErabAddFailNbr_CP _BH_CAC_FAIL

count

A call is released due to insufficient backhaul-based eNB resources during additional ERAB setup.

CC

event

int

0-2147483647

ErabAddFailNbr_CP _CAPA_CAC_FAIL

count

A call is released due to insufficient capacity-based eNB resources during additional ERAB setup.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 70 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ErabAddFailNbr_CP _QOS_CAC_FAIL

Unit count

Description A call is released due to insufficient QoS-based eNB resources during additional ERAB setup.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ErabAddFailNbr_S1 AP_CU_FAIL

count

A call is released due to the S1AP specification cause during additional ERAB setup.

CC

event

int

0-2147483647

ErabAddFailNbr_S1 AP_LINK_FAIL

count

A call is released due to S1 SCTP link failure during additional ERAB setup

CC

event

int

0-2147483647

ErabAddFailNbr_S1 AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during additional ERAB setup.

CC

event

int

0-2147483647

ErabAddFailNbr_CP_ CC_INTERACTION

count

A failure occurs due to ERAB Setup request from the MME during inter eNB handover

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 71 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_CONNECTED E-RAB Setup Request Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete E-RAB Setup Response 2 Success 1 Attempt MME S/GW

RRC_CONNECTED

Figure 9. Collection Time for E-RAB Setup Add

For additional E-RAB setup count statistics, Attempt is counted when the E-RAB Setup Request message is received during the additio nal E-RAB setup. Success is counted when the E-RAB Setup Response message is transmitted. A failure is counted when a timeout or failure occurs during the procedure and the applicable cause value is recorded.

SAMSUNG Electronics Co., Ltd.

page 72 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.3

E-RAB Setup Time


This section provides statistics data for the average E-RAB Setup time and the maximum E-RAB Setup time. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name EstabTime Unit ms Description Average E-RAB setup time Visible Y Counter Type GAUGE Trigger Type event Data Type int Min/Max 0-60*Period*1000 Granularity Formula EstabTimeTot/Est abTimeCnt EstabTimeMax ms Maximum E-RAB setup time Y GAUGE event int 0-60*Period*1000 Hourly, Daily, Monthly Formula sum (EstabTimeTot)/ sum (EstabTimeCnt) max (EstabTimeMax) EstabTimeTot EstabTimeCnt ms count Sum of EstabTime collected Number of EstabTime events collected Y Y GAUGE GAUGE event event int int 0-2147483647 0-2147483647 -

SAMSUNG Electronics Co., Ltd.

page 73 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE Initial Context Setup Request Security Mode Command Security Mode Complete RRC Connection Reconfiguration RRC Connection Reconfiguration Complete Initial Context Setup Response
E-RAB Setup time

MME

S/GW

RRC_CONNECTED

Figure 10. Collection Time for E-RAB Setup Time

The E-RAB setup time indicates the duration from receiving the Initial Context Setup Request message up to transmitting the Initial C ontext Setup Response, which is reported in milliseconds. The statistics block calculates the average and maximum values of the setup time during the collection period.

SAMSUNG Electronics Co., Ltd.

page 74 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.4

eNB E-RAB Erase Request


This section provides statistics data for the E-RAB release requests made by the eNB by transmitting the UE Context Release Request message. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Serving Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name EraseAttbyEnb_ CP_CC_TO Unit count Description A call is released due to the call control timeout of the protocol block (MAC, RLC, PDCP, GTP) when an eNBinitiated UE Context Release occurs. A call is released due to reset notification (eNB failure or block restart) from ECMB when an eNB-initiated UE Context Release occurs or by the ECCB block. A call is released due to internal failure of the GTP block when an eNB-initiated UE Context Release occurs. A call is released due to internal failure of the MAC block when an eNB-initiated Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula

EraseAttbyEnb_ CP_CC_FAIL

count

CC

event

int

0-2147483647

EraseAttbyEnb_ UP_GTP_FAIL EraseAttbyEnb_ UP_MAC_FAIL

count

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 75 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description UE Context Release occurs.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

EraseAttbyEnb_ UP_MAC_UE_I NACT EraseAttbyEnb_ UP_PDCP_FAI L EraseAttbyEnb_ UP_RLC_FAIL EraseAttbyEnb_ RRC_HC_TO EraseAttbyEnb_ RRC_SIG_FAIL EraseAttbyEnb_ RRC_SIG_TO EraseAttbyEnb_ S1AP_CU_FAIL EraseAttbyEnb_ S1AP_RO_TO

count

A call is released due to UE inactivity in eNB when an eNB-initiated UE Context Release occurs. A call is released due to internal failure of the PDCP block when an eNBinitiated UE Context Release occurs. A call is released due to internal failure of the RLC block when an eNB-initiated UE Context Release occurs. A call is released due to HO command timeout (not received) when an eNBinitiated UE Context Release occurs. A call is released due to receiving RRC signaling when an eNB-initiated UE Context Release occurs. A call is released due to S1AP signaling timeout (not received) when an eNBinitiated UE Context Release occurs. A call is released due to the S1AP specification cause occurred when an eNB-initiated UE Context Release occurs. A call is released due to S1AP RelocOverall timeout (not received) when an eNB-initiated UE Context Release occurs. A call is released due to S1AP signaling

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

cont

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

EraseAttbyEnb_

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 76 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S1AP_SIG_TO EraseAttbyEnb_ X2AP_RO_TO

Unit

Description timeout (not received) when an eNBinitiated UE Context Release occurs.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

A call is released due to X2AP RelocOverall timeout (not received) when an eNB-initiated UE Context Release occurs.

CC

event

int

0-2147483647

Collection Time
UE eNB RRC_CONNECTED Count RRC Connection Release 1 UE Context Release Request UE Context Release Command MME S/GW

UE Context Release Complete

RRC_CONNECTED

Figure 11. Collection Time for eNB E-RAB Erase Request

The eNB E-RAB erase request refers to deleting the UE context. When the eNB needs to release the UE context, it transmits the UE Context Release Request message to the MME, and counts statistics.

SAMSUNG Electronics Co., Ltd.

page 77 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.5

E-RAB Erase
This section provides statistics data for the E-RAB release requests made by the eNB using the UE Context Release command. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name EraseAtt Unit count Description The number of the E-RAB release attempts using the UE Context Release command. EraseSucc count The number of the E-RAB release successes using the UE Context Release command. Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 78 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_CONNECTED UE Context Release Command MME S/GW

Attempt

Rrc Connection Release

Success

UE Context Release Complete

RRC_CONNECTED

Figure 12. Collection Time for E-RAB Erase

For E-RAB ERASE statistics, attempt is counted when the UE Context Release Command is received from the MME. Success is coun ted when the UE Context Release Complete message is transmitted.

SAMSUNG Electronics Co., Ltd.

page 79 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.6

E-RAB Modify
This section provides statistics data for the E-RAB Modify count. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name ModQoSAttNbr Unit count Description The number of ERAB Modify attempts. ModQoSSuccNbr count The number of ERAB Modify successes. ModQoSFailNbr_ CP_CC_TO count A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during ERAB Modify. ModQoSFailNbr_ CP_CC_FAIL count A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during ERAB Modify. ModQoSFailNbr_ count A call is released due to the failure Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 80 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UP_GTP_FAIL

Unit

Description in the GTP block during ERAB Modify.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ModQoSFailNbr_ UP_MAC_FAIL

count

A call is released due to the failure in the MAC block during ERAB Modify.

CC

event

int

0-2147483647

ModQoSFailNbr_ UP_PDCP_FAIL

count

A call is released due to the failure in the PDCP block during ERAB Modify.

CC

event

int

0-2147483647

ModQoSFailNbr_ UP_RLC_FAIL

count

A call is released due to the failure in the RLC block during ERAB Modify.

CC

event

int

0-2147483647

ModQoSFailNbr_ RRC_SIG_FAIL ModQoSFailNbr_ RRC_SIG_TO

count

A call is released due to receiving RRC signaling during ERAB Modify.

CC

event

int

0-2147483647

count

A call is released due to ERAB uplink message timeout (not received) during RRC Modify procedure

CC

event

int

0-2147483647

ModQoSFailNbr_C P_BH_CAC_FAIL

count

A call is released due to insufficient backhaul-based eNB resources during ERAB Modify.

CC

event

int

0-2147483647

ModQoSFailNbr_ CP_CAPA_CAC_ FAIL ModQoSFailNbr_ CP_QOS_CAC_F

count

A call is released due to insufficient capacity-based eNB resources during ERAB Modify.

CC

event

int

0-2147483647

count

A call is released due to insufficient QoS-based eNB resources during

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 81 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name AIL ModQoSFailNbr_ S1AP_CU_FAIL

Unit

Description ERAB Modify.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

A call is released due to the S1AP specification cause during ERAB Modify.

CC

event

int

0-2147483647

ModQoSFailNbr_ S1AP_LINK_FAIL ModQoSFailNbr_ S1AP_SIG_FAIL

count

A call is released due to S1 SCTP link failure during ERAB Modify.

CC

event

int

0-2147483647

count

A call is released due to receiving S1AP signaling during ERAB Modify.

CC

event

int

0-2147483647

ModQoSFailNbr_ CP_CC_INTERA CTION

count

A failure occurs due to ERAB Modify request from the MME during inter eNB handover

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 82 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_CONNECTED E-RAB Modify Request MME S/GW

Attempt

Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete E-RAB Modify Response

Success

RRC_CONNECTED

Figure 13. Collection Time for E-RAB Modify

For E-RAB Modify statistics, Attempt is counted when the E-RAB Modify Request message is received from the MME, and Success i s counted when the E-RAB Modify Response message is transmitted. A failure is counted when the E-RAB Modify procedure fails du e to an internal timeout or failure, and the applicable cause value is recorded.

SAMSUNG Electronics Co., Ltd.

page 83 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.7

eNB E-RAB Release Request


This section provides statistics data for the E-RAB release requests made by the eNB using the E-RAB Release Indication message. E-RAB release request usually occurs when only a specific bearer is released while two or more bearers are set up. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name RelAttbyEnbN br_CP_CC_TO Unit count Description A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during eNBinitiated ERAB release. RelAttbyEnbN br_S1AP_CU_ FAIL count Release due the S1AP specification cause during eNB-initiated ERAB release. Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 84 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_CONNECTED Count 1 E-RAB Release Indication E-RAB Release Command Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete E-RAB Release Response MME S/GW

RRC_CONNECTED

Figure 14. Collection Time for eNB E-RAB Erase Request

The eNB E-RAB Release statistics are counted when the eNB deletes the applicable bearers as needed and transmits the E-RAB Relea se Indication message to the MME.

SAMSUNG Electronics Co., Ltd.

page 85 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.8

E-RAB Release
This section provides statistics data for the E-RAB releases made by the eNB using the E-RAB Release Command. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name RelAttNbr Unit count Description Attempt count for E-RAB release by the ERAB Release command RelSuccNbr count Success count for E-RAB release by the ERAB Release command RelFailNbr_C P_CC_FAIL count A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during MME-initiated ERAB release. RelFailNbr_S1 AP_SIG_FAIL count A call is released due to receiving S1AP signaling during MME-initiated ERAB release. RelFailNbr_S1 AP_CU_FAIL count A call is released due to S1AP specification cause during MME-initiated ERAB release. Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 86 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RelActive

Unit count

Description Number of active E-RABs, for which a call is released due to abnormal operation in eNB.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RelFailNbr_C P_CC_INTER ACTION

count

A failure occurs due to ERAB Release request from the MME during inter eNB handover

CC

event

int

0-2147483647

Collection Time
UE eNB RRC_CONNECTED E-RAB Release Command MME S/GW

Attempt

Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete E-RAB Release Response

Success

RRC_CONNECTED

Figure 15. Collection Time for E-RAB Release

For E-RAB release statistics, Attempt is counted when the E-RAB Release Request message is received from the MME. Success is co unted when the E-RAB Release Response message is transmitted. If a failure is counted when the E-RAB Release procedure fails due to an internal timeout or failure, and the applicable cause value is recorded.
page 87 of 427

SAMSUNG Electronics Co., Ltd.

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.9

E-RAB Activity (UE)


This section provides statistics data for the in-session time of the UE. In-session is defined as valid if a data transmission took place during the last 100 ms; it collects the in-session time of the UE which had data transmissions with the PDSCH/PUSCH during the stat istics period. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name SessionTime UE Unit ms Description Average in-session time per UE Visible Y Counter Type SI Trigger Type 5.12 s. Data Type float Min/Max 0-60*Period* 1000 Granularity Formula SessionTimeUETot)/ SessionTimeUECnt Hourly, Daily, Monthly Formula sum (SessionTimeUETot)/ sum (SessionTimeUECnt) SessionTime UETot SessionTime UECnt count ms Sum of SessionTimeUE collected Collected SessionTimeUE count SI 5.12 s int 0~2147483647 Y SI 5.12 s. float 0-3.4*10^38 -

Collection Time TTI

SAMSUNG Electronics Co., Ltd.

page 88 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.10 E-RAB Activity (QCI)


This section provides statistics data for the in-session time per QCI. In-session is defined as valid if a data transmission took place dur ing the last 100 ms; it collects the in-session time of the Bearer which had data transmissions with the PDSCH/PUSCH during the stat istics period for each QCI. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name SessionTimeQ CI Unit ms Description Average in-session time per QCI Visible Y Counter Type SI Trigger Type 5.12 s. Data Type float Min/Max 060*Period* 1000 SessionTimeQ CITot SessionTimeQ CICnt count ms Sum of SessionTimeQCI collected Collected SessionTimeQCI count SI 5.12sec int Y SI 5.12 s. float 03.4*10^38 0~2147483 647 Granularity Formula SessionTimeQ CITot/SessionT imeQCICnt Hourly, Daily, Monthly Formula sum (SessionTimeQCITot)/ sum (SessionTimeQCICnt)

Collection Time TTI

SAMSUNG Electronics Co., Ltd.

page 89 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

4.11 E-RAB Simultaneous Number


This section provides statistics data for the average E-RAB count and the maximum E-RAB count per unit time. Index
Name cNum QCI 0~2 0~255 Range Cell Index QoS Class Identifier Description

Type
Name UsageNbr Unit count Description Average E-RAB count per unit time. Visible Y Counter Type GAUGE Trigger Type 2 s. Data Type float Min/Max 0-3.4*10^38 Granularity Formula UsageNbrTot/ UsageNbrCnt Hourly, Daily, Monthly Formula sum (UsageNbrTot)/ sum (UsageNbrCnt) UsageNbrMax count Maximum E-RAB count per unit time. UsageNbrTot count The sum of collected UsageNbr UsageNbrCnt count Collected UsageNbr count GAUGE 2s int 0~2147483647 GAUGE 2s float 0~3.4*10^38 Y GAUGE 2 s. float 0-3.4*10^38 max (UsageNbrMax) -

SAMSUNG Electronics Co., Ltd.

page 90 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Handover (HO) EUTRAN


The statistics on handovers are collected for intra LTE handover and inter RAT han dover respectively. Intra LTE handover includes intra eNB, inter eNB S1, and inter eNB X2 handovers. Inter RAT handover includes inter RAT optimized HRPD and i nter RAT UTRAN handovers. Intra-LTE handover statistics are based on the source and target cells, which are col lected through the respective source and target eNBs. Inter-RAT handover statistics are based on the eNBs served cells. Intra eNB Handover This section provides statistics data for handovers between cells within the eNB. Int ra eNB handover is performed when the UE moves between the cells that belong t o the same eNB. The following figure illustrates this procedure.

UE

Source cell

Target cell

1)

MeasurementReport

HO attempt 2) Target Cell Preparation

3)

RRCConnection-Reconfiguration
(mobilityControlinfo)

HO preparation

HO success

4)

RRCConnectionReconfigurationComplete

Figure 16. Intra eNB Handover Statistics Processing

Steps 1) 2) 3)

Description Intra eNB handover is determined based on the measurement report. New RLC, MAC and PHY configurations are set for the target cell. When the resource setup is completed in the target cell, the RRC Connection Reconfiguration message is transmitted to instruct the UE to perform handover.

4)

The RRC Connection Reconfiguration Complete message is received to complete the intra handover successfully.

SAMSUNG Electronics Co., Ltd.

page 91 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

X2 Handover When the UE moves between cells of different eNBs that belong to the same MM E group, handover is performed via the X2 interface. Upon performing the X2 han dover, the source provides the statistics on outgoing handover; and the target provid es statistics for incoming. The procedure of collecting Attempt, Preparation, and Success statistics is shown in the following figure.

EPC UE Source eNB Target eNB MME S-GW

Downlink/Uplink data

Downlink/Uplink data

1)

MeasurementReport 2) HANDOVER REQUEST HANDOVER REQUEST ACKNOWLEDGE

HO attempt

4)

RRCConnectionReconfiguration
(mobilityControlinfo)

3)

HO Preparation

5) SN STATUS TRANSFER
Data forwarding

6) Synchronization/UL allocation and timing advance 7) RRCConnectionReconfigurationComplete


Forwarded data Uplink data Uplink data

8) PATH SWITCH REQUEST 9)


End marker Forwarded data End marker Downlink data Downlink data

Modify Bearer Request

12) UE CONTEXT RELEASE


Down/Uplink data

11) PATH SWITCH REQUEST ACKNOWLEDGE

10) Modify Bearer Response HO Success

Down/Uplink data

Figure 17. X2-based Handover Statistics Processing

SAMSUNG Electronics Co., Ltd.

page 92 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Step 1)

Description The UE transmits the MeasurementReport message according to the system information, standards and rules. The source eNB determines whether to perform the UE handover based on the MeasurementReport message and the radio resource management information.

2)

The source eNB sends the target eNB a HANDOVER REQUEST message containing the information required for handover. The target eNB can perform management control in accordance with the E-RAB QoS information received.

3)-4)

The target eNB creates the RRCConnectionReconfiguration message which contains the mobileControlInfo IE for preparing and executing the handover. The target eNB transmits RRCConnectionReconfiguration to the source eNB, which is encapsulated in the HANDOVER REQUEST ACKNOWLEDGE message. The source eNB transmits the RRCConnectionReconfiguration message and the necessary parameters to the UE to command it to perform the handover.

5)

To transmit the uplink PDCP SN receiver status and the downlink PDCP SN transmitter status of the E-RABs of which the PDCP status must be preserved, the source eNB transmits the SN STATUS TRANSFER message to the target eNB.

6)

After receiving the RRCConnectionReconfiguration message that encapsulates the mobileControlInfo IE, the UE performs synchronization with the target eNB and accesses the target cell via the Random Access CHannel (RACH). The target eNB responds with UL allocation and a timing advance value.

7)

After having connected to the target cell successfully, the UE notifies the target eNB that the Handover procedure has been completed using an RRCConnectionReconfigurationComplete message.

8)

The target eNB, using the PATH SWITCH REQUEST message, notifies the MME that the UE has changed the cell.

9)-10)

The MME sends the Modify Bearer Request message to the S-GW. The S-GW changes the downlink data path into the target eNB. The S-GW transmits at least one end marker to the source eNB through the previous path, and releases the user plane resources for the source eNB. The S-GW transmits a Modify Bearer Response message to the MME.

11)

The MME transmits the PATH SWITCH REQUEST ACKNOWLEDGE message to acknowledge the PATH SWITCH REQUEST message

12)

The target eNB sends the UE CONTEXT RELEASE message to the source eNB to notify the handover has succeeded and to make the source eNB release its resources. If the source eNB receives the UE CONTEXT RELEASE message, it release the radio resources and the control plane resources related to the UE context.

SAMSUNG Electronics Co., Ltd.

page 93 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

S1 Handover Generally, when two eNBs belong to the same MME group, handover is performed via the X2 interface, and if two eNBs belong to different MME groups, handover is performed via the S1 interface. However, if they belong to the same MME, but there is no X2 interface between the two eNBs or there is X2 link failure, handove r is performed via the S1 interface. Upon performing the S1 handover, the source provides the statistics on outgoing ha ndover; and the target provides statistics for the incoming handover. The procedure of collecting Attempt, Preparation, and Success statistics is shown be low.

SAMSUNG Electronics Co., Ltd.

page 94 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

EPC UE Source eNB Target eNB MME S-GW

Downlink/Uplink data

Downlink/Uplink data

1) Decision to trigger a relocation via S1

HO attempt

2)

HANDOVER REQUIRED HANDOVER REQUEST

HO attempt 3) 4)

Ho Preparation HO Preparation RRCConnectionReconfiguration


(mobilityControlinfo)

8)

HANDOVER REQUEST ACKNOWLEDGE 5) Create Indirect Data Forwarding Tunnel Request 6) Create Indirect Data 7) HANDOVER COMMAND Forwarding Tunnel Response

9) eNB STATUS TRANSFER 10) MME STATUS TRANSFER


1) Direct data forwarding 2) Indirect data forwarding Indirect data forwarding

11) Detach from old cell/Synchronize to new cell 12) RRCConnectionReconfigurationComplete


Forwarded data Uplink data Uplink data

13) HANDOVER NOTIFY Ho Success 14) Modify Bearer Request 15) Modify Bearer Response
End marker Forwarded data End marker Downlink data Downlink data

16) Tracking Area Update procedure 17) UE CONTEXT RELEASE COMMAND Ho Success 18) UE CONTEXT RELEASE COMPLETE 19) Delete Indirect Data Forwarding Tunnel Request 20) Delete Indirect Data Forwarding Tunnel Response

Downlink/Uplink data

Downlink/Uplink data

Figure 18. S1-based Handover Procedure

SAMSUNG Electronics Co., Ltd.

page 95 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Step 1)

Description The source eNB determines whether to perform S1-based handover into the target eNB. The source eNB can make this decision when there is no X2 connection to the target or when an error is notified by the target eNB after an X2-based handover has failed, or based on the information the source eNB has obtained dynamically.

2)

The source eNB transmits the HANDOVER REQUIRED message to the MME. The source eNB notifies the target eNB which bearer is used for data forwarding and whether forwarding can be made directly from the source eNB to the target eNB.

3)-4)

The MME transmits the HANDOVER REQUEST message to the target eNB. This message makes the target eNB create a UE context containing the bearer-related information and the security context. The target eNB transmits the HANDOVER REQUEST ACKNOWLEDGE message to the MME.

5)-6)

If indirect forwarding is used, the MME sends the Create Indirect Data Forwarding Tunnel Request message to the S-GW. The S-GW replies the MME with the Create Indirect Data Forwarding Tunnel Response message.

7)-8)

The MME sends the HANDOVER COMMAND message to the source eNB. The source eNB creates the RRCConnectionReconfiguration message using the Target to Source Transparent Container IE encapsulated in the HANDOVER COMMAND message and then transmits it to the UE.

9)-10)

To transmit the PDCP and HFN status of the E-RABs of which the PDCP status must be preserved, the source eNB transmits the eNB/MME STATUS TRANSFER message to the target eNB via the MME. The source eNB must start forwarding the downlink data to the target eNB through the bearer which was determined to be used for data forwarding. This can be either direct or indirect forwarding.

11)

The UE performs synchronization with the target eNB and connects to the target cell via a RACH. The target eNB responds with UL allocation and a timing advance value.

12)

After having synchronized with the target cell, the UE notifies the target eNB that the Handover procedure has been completed using the RRCConnectionReconfigurationComplete message. The downlink packets forwarded from the source eNB can be transmitted to the UE. The uplink packets can also be transmitted from the UE to the S-GW via the target eNB.

13)

The target eNB sends the HANDOVER NOTIFY message to the MME. The MME starts the timer which tells when the resources of the source eNB and the temporary resources used by the S-GW for indirect forwarding will be released.

14)

The MME transmits the Modify Bearer Request message for each PDN connection to the S-GW. Downlink packets are transmitted from the S-GW to the target eNB immediately.

15)

The S-GW transmits a Modify Bearer Response message to the MME. As soon as the target eNB changes the path to help packet reordering, the S-GW transmits at least one end marker packet to the source eNB through the previous path.

16)

If any of the conditions listed in section 5.3.3.0 of TS 23.401 (6) are met, the UE starts

SAMSUNG Electronics Co., Ltd.

page 96 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Step the Tracking Area Update procedure. 17)-18)

Description

When the timer started at step 13) expires, the MME sends the UE CONTEXT RELEASE COMMAND message to the source eNB. The source eNB releases the resources related to the UE and replies with the UE CONTEXT RELEASE COMPLETE message.

19)-20)

If indirect forwarding has been used, when the timer started at Step 13 expires the MME transmits the Delete Indirect Data Forwarding Tunnel Request message to the S-GW. This message gets the S-GW to release the temporary resources allocated for indirect forwarding at Step 5). The S-GW responds to the MME with the Delete Indirect Data Forwarding Tunnel Response message.

SAMSUNG Electronics Co., Ltd.

page 97 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.1

Intra eNB Handover


This section provides statistics data for handovers between cells within the eNB. Index
Name cNum tcId HOCause 0~2 0~268435455 0~1 Range Source Cell Index Target Cell Index Handover cause 0: Handover desirable for radio reasons 1: reserved Description

Type
Name IntraEnbAtt IntraEnbPrepSucc Unit count count Description Intra-handover attempt count. Intra-handover preparation success count. IntraEnbSucc count Intra-handover execution success count. IntraEnbPrepFail_ CP_CC_TO count Preparation fails due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the intra handover preparation. IntraEnbPrepFail_ CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Y Counter Type CC CC Trigger Type event event Data Type int int Min/Max 0-2147483647 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 98 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description restart) from ECMB or by the ECCB block during the intra handover preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

IntraEnbPrepFail_ UP_MAC_FAIL

count

Preparation fails due to internal failure in the MAC block during the intra handover preparation.

CC

event

int

0-2147483647

IntraEnbPrepFail_ UP_RLC_FAIL

count

Preparation fails due to internal failure in the RLC block during the intra handover preparation.

CC

event

int

0-2147483647

IntraEnbPrepFail_ RRC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the intra handover preparation.

CC

event

int

0-2147483647

IntraEnbPrepFail_ CP_BH_CAC_FAI L

count

Preparation fails due to insufficient backhaul-based eNB resources during the intra handover preparation.

CC

event

int

0-2147483647

IntraEnbPrepFail_ CP_CAPA_CAC_ FAIL

count

Preparation fails due to insufficient capacity-based eNB resources during the intra handover preparation.

CC

event

int

0-2147483647

IntraEnbPrepFail_ CP_QOS_CAC_F AIL IntraEnbPrepFail_ S1AP_CU_FAIL

count

Preparation fails due to insufficient QoS-based eNB resources during the intra handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to S1AP specification cause during the intra handover preparation.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 99 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name IntraEnbPrepFail_ S1AP_LINK_FAIL

Unit count

Description Preparation fails due to S1 SCTP link failure during the intra handover preparation.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

IntraEnbPrepFail_ S1AP_SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during the intra handover preparation.

CC

event

int

0-2147483647

IntraEnbFail_CP_ CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_CP_ CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_UP_ GTP_FAIL

count

A call is released due to the internal failure in the GTP block during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_UP_ MAC_FAIL

count

A call is released due to the internal failure in the MAC block during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_UP_ RLC_FAIL

count

A call is released due to the internal failure in the RLC block during the intra handover

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 100 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit execution.

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

IntraEnbFail_RR C_HC_TO

count

A call is released due to HO command timeout (not received) during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_RR C_SIG_FAIL

count

A call is released due to receiving RRC signaling during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_S1A P_CU_FAIL

count

A call is released due to the S1AP specification cause during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_S1A P_LINK_FAIL

count

A call is released due to S1 SCTP link failure during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbFail_S1A P_SIG_FAIL

count

A call is released due to S1AP signaling timeout (not received) during the intra handover execution.

CC

event

int

0-2147483647

IntraEnbCnt

count

Intra-eNB handover collection count

CC

event

int

0~2147483647

IntraEnbNbrCid

tcID

tcID of which collection is requested

OW

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 101 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE UE moves to Intra eNB Cell Measurement Report Attempt 1 HO Decision eNB

Prepare Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete Success

Target Cell Preparation

Internal Path Switch

Figure 19. Collection Time for Intra eNB Handover

For intra-handover statistics, Attempt is counted when an intra-handover is decided after the Measurement Report message arrival, and Prepare is counted when the intra-handover preparation is complete and at the time of transmitting the RRC Connection Reconfiguratio n message to the UE. Success is counted when the target cell successfully receives the RRC Connection Reconfiguration Complete mes sage from the UE. If the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fai ls, it is counted as Intra Fail, returning the cause value.

SAMSUNG Electronics Co., Ltd.

page 102 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.2

X2 Handover Out
This section provides statistics data for X2 handover between eNBs in reference with the source eNB. Index
Name cNum tcId HOCause 0~2 0-268435455 0-1 Range Source Cell Index Target Cell Index Handover cause 0: Handover desirable for radio reasons 1: reserved Description

Type
Name InterX2OutAtt Unit count Description Attempt count for X2 handover from SeNB. InterX2OutPrepSu cc InterX2OutSucc count count Success count for X2 handover preparation from SeNB. Success count for X2 handover execution from SeNB. InterX2OutPrepFail _CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during the inter X2 handover preparation. Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 103 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name InterX2OutPrepFail _S1AP_LINK_FAIL

Unit count

Description Preparation fails due to S1 SCTP link failure during the inter X2 handover preparation.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

InterX2OutPrepFail _S1AP_SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2OutPrepFail _X2AP_CU_FAIL

count

Preparation fails due to X2AP specification cause during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2OutPrepFail _X2AP_LINK_FAIL

count

Preparation fails due to X2 SCTP link failure during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2OutPrepFail _X2AP_RP_TO

count

Preparation fails due to X2AP relocprep timeout (not received) during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2OutPrepFail _X2AP_SIG_FAIL

count

Preparation fails due to receiving X2AP signaling during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2OutFail_CP _CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_CP _CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 104 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description block during the inter X2 handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterX2OutFail_UP _GTP_FAIL

count

A call is released due to the failure in the GTP block during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_UP _MAC_FAIL

count

A call is released due to the internal failure in the MAC block during the inter X2 handover execution.

CC

event

int

0-214783647

InterX2OutFail_UP _PDCP_FAIL

count

A call is released due to the internal failure in the PDCP block during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_UP _RLC_FAIL

count

A call is released due to the internal failure in the RLC block during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_ RRC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_ S1AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_S1 AP_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_S1 AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the inter X2

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 105 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterX2OutFail_X2 AP_CU_FAIL

count

A call is released due to the X2AP specification cause during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_X2 AP_LINK_FAIL

count

A call is released due to the X2 SCTP link failure during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_X2 AP_RO_TO

count

A call is released due to X2AP RelocOverall timeout (not received) during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutFail_X2 AP_SIG_FAIL

count

A call is released due to receiving the X2AP signaling during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2OutCnt

count

X2 Handover Out collection count

CC

event

int

0~214748364 7

InterX2OutCid

tcID

tcID of which collection is requested

OW

event

int

0~214748364 7

SAMSUNG Electronics Co., Ltd.

page 106 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE Source eNB Target eNB MME S/GW

UE moves to Inter eNB Cell Measurement Report HO Decision 1 Attempt

Handover Request 2 Prepare Handover Request Acknowledge SN Status Transfer

Rrc Connection Reconfiguration

Rrc Connection Reconfiguration Complete Path Switch Request Path Switch Request Acknowledge Release Request Call Release 3 Success

Figure 20. Collection Time for X2 Handover Out

SAMSUNG Electronics Co., Ltd.

page 107 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

For Inter X2 Handover Out statistics, Attempt is counted when the X2 Handover Request message is transmitted to the target eNB aft er the inter X2 handover decision following the Measurement Report message arrival. Prepare is counted when the X2 Handover Reque st Acknowledge message is received from the target eNB. The source eNB transmits the RRC Connection Reconfiguration message to t he UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the UE. The target eNB transmits the X2 UE Context Release message to the source eNB when the handover is successfully completed. At thi s point, the source eNB is counted as Success. If the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fails, it is counted as Inter X2 Fail, returning the cause value.

SAMSUNG Electronics Co., Ltd.

page 108 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.3

X2 Handover In
This section provides statistics data for X2 handover between eNBs in reference with the target eNB. Index
Name cNum HOCause 0~2 0~1 Range Target Cell Index Handover cause 0: Handover desirable for radio reasons 1: reserved Description

Type
Name InterX2InAtt Unit count Description The number of attempts for X2 handover in TeNB InterX2InPrepSu cc InterX2InSucc count count The number of successes for X2 handover preparation in TeNB The number of successes for X2 handover execution in TeNB InterX2InPrepFai l_CP_CC_TO count Preparation fails due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the inter X2 handover preparation. InterX2InPrepFai l_CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 109 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description restart) from ECMB or by ECCB block during the inter X2 handover preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterX2InPrepFai l_UP_GTP_FAIL

count

Preparation fails due to internal failure in the GTP block during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2InPrepFai l_UP_MAC_FAIL

count

Preparation fails due to internal failure in the MAC block during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2InPrepFai l_UP_PDCP_FAI L InterX2InPrepFai l_UP_RLC_FAIL

count

Preparation fails due to internal failure in the PDCP block during the inter X2 handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to internal failure in the RLC block during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2InPrepFai l_CP_BH_CAC_ FAIL

count

Preparation fails due to insufficient backhaul-based eNB resources during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2InPrepFai l_CP_CAPA_CA C_FAIL

count

Preparation fails due to insufficient capacity-based eNB resources during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2InPrepFai l_CP_QOS_CAC _FAIL

count

Preparation fails due to insufficient QoS-based eNB resources during the inter X2 handover preparation.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 110 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name InterX2InPrepFai l_S1AP_LINK_F AIL InterX2InPrepFai l_S1AP_SIG_FA IL InterX2InPrepFail _X2AP_CU_FAIL

Unit count

Description Preparation fails due to S1 SCTP link failure during the inter X2 handover preparation.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Preparation fails due to receiving S1AP signaling during the inter X2 handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to X2AP specification cause during the inter X2 handover preparation.

CC

event

int

0-2147483647

InterX2InPrepFai l_X2AP_LINK_F AIL InterX2InPrepFai l_X2AP_SIG_FA IL InterX2InFail_CP _CC_TO

count

Preparation fails due to X2 SCTP link failure during the inter X2 handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to receiving X2AP signaling during the inter X2 handover preparation.

CC

event

int

0-2147483647

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_CP _CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_UP _GTP_FAIL

count

A call is released due to the failure in the GTP block during the inter X2

CC

event

int

0-217483647

SAMSUNG Electronics Co., Ltd.

page 111 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterX2InFail_UP _MAC_FAIL

count

A call is released due to the internal failure in the MAC block during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_UP _PDCP_FAIL

count

A call is released due to the internal failure in the PDCP block during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_UP _RLC_FAIL

count

A call is released due to the internal failure in the RLC block during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_R RC_HC_TO

count

A call is released due to HO command timeout (not received) during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_R RC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_S1 AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_S1 AP_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_S1 AP_PATH_TO

count

A call is released due to S1AP path switch timeout (not received) during

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 112 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description the inter X2 handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterX2InFail_S1 AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_X2 AP_CU_FAIL

count

A call is released due to the X2AP specification cause during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_X2 AP_LINK_FAIL

count

A call is released due to the X2 SCTP link failure during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_X2 AP_SIG_FAIL

count

A call is released due to receiving the X2AP signaling during the inter X2 handover execution.

CC

event

int

0-2147483647

InterX2InFail_X2 AP_SIG_TO

count

A call is released due to X2AP signaling timeout (not received) during the inter X2 handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 113 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE Source eNB Target eNB MME S/GW

UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Rrc Connection Reconfiguration Acknowledge SN Status Transfer 1 2 Attempt Prepare

Rrc Connection Reconfiguration Complete Path Switch Request Path Switch Request Release Request Call Release 3 Acknowledge Success

Figure 21. Collection Time for X2 Handover In

For Inter X2 Handover In statistics, Attempt is counted when the target eNB receives the X2 Handover Request message, and Prepare is counted after the target eNB transmits the X2 Handover Request Acknowledge message. The source eNB transmits the RRC Connec tion Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message from the UE. Success is counted when the handover is completed successfully and the X2 UE Context Release message is transmitted to the s ource eNB. If the procedure from to fails, it is counted as Prepare Fail and returns the cause value and when the procedure fro m to fails, it is counted as Inter X2 In Fail and returns the cause value.
SAMSUNG Electronics Co., Ltd. page 114 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.4

S1 Handover Out
This section provides statistics data for S1 handovers between eNBs for each cell in reference with the source eNB. Index
Name cNum tcId HOCause 0~2 0~268435455 0~1 Range Source Cell Index Target Cell Index Handover cause 0: Handover desirable for radio reasons 1: reserved Description

Type
Name InterS1OutAtt Unit count Description The number of attempts for S1 handover in SeNB InterS1OutPrepS ucc InterS1OutSucc count count The number of successes for S1 handover preparation in SeNB The number of successes for S1 handover execution in SeNB InterS1OutPrepF ail_CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during inter S1 handover preparation. InterS1OutPrepF count Preparation fails due to S1AP Y CC event int 0-2147483647 Y CC event int 0~214748364 7 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 115 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ail_S1AP_CU_F AIL InterS1OutPrepF ail_S1AP_LINK_ FAIL InterS1OutPrepF ail_S1AP_RP_T O

Unit

Description specification cause during inter S1 handover preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Preparation fails due to S1 SCTP link failure during inter S1 handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to S1AP relocprep timeout (not received) during the inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1OutPrepF ail_S1AP_SIG_F AIL InterS1OutFail_C P_CC_TO

count

Preparation fails due to receiving S1AP signaling during inter S1 handover preparation.

CC

event

int

0-2147483647

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_C P_CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_U P_GTP_FAIL

count

A call is released due to the failure in the GTP block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_U P_MAC_FAIL

count

A call is released due to the failure in the MAC block during the inter S1

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 116 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterS1OutFail_U P_PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_U P_RLC_FAIL

count

A call is released due to the failure in the RLC block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_R RC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_S 1AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_S 1AP_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_S 1AP_RO_TO

count

A call is released due to S1AP relocoverall timeout (not received) during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutFail_S 1AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1OutCnt InterS1OutCid

count tcID

S1 Handover Out collection count tcID of which collection is requested

CC OW

event event

int int

0~2147483647 0~2147483647

SAMSUNG Electronics Co., Ltd.

page 117 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE Source eNB Target eNB MME S/GW

UE moves to Inter eNB Cell Measurement Report HO Decision 1 Attempt Handover Required Handover Request Handover Request 2 Prepare Acknowledge Handover Command eNB Status Transfer MME Status Transfer Rrc Connection Reconfiguration Complete Handover Notify Tracking Area Update Procedure (NAS) UE Context Release Command UE Context Release Complete Call Release 3 Success

Rrc Connection Reconfiguration

Figure 22. Collection Time for S1 Handover Out

SAMSUNG Electronics Co., Ltd.

page 118 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

For Inter S1 Handover Out statistics, Attempt is counted when the S1 Handover Required message can be transmitted to the MME aft er the inter S1 handover decision following the Measurement Report message arrival. Prepare is counted when the S1 Handover Comm and message is received from the MME. The source eNB transmits the RRC Connection Reconfiguration message to the UE, and the t arget eNB receives the RRC Connection Reconfiguration Complete message from the UE. The MME transmits the S1 UE Context Release Command message to the source eNB when the handover is successfully completed in the target eNB. At this point, the source eNB is counted as Success. When the procedure from to fails, it is counted as Prepar e Fail and returns the cause value, and when the procedure from to fails, it is counted as Inter S1 Out Fail and returns the cau se value.

SAMSUNG Electronics Co., Ltd.

page 119 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.5

S1 Handover In
This section provides statistics data for S1 handovers between eNBs for each cell in reference with the target eNB. Index
Name cNum HOCause 0~2 0~1 Range Target cell index Handover cause 0: Handover desirable for radio reasons 1: reserved Description

Type
Name InterS1InAtt InterS1InPrepSucc Unit count count Description S1 handover attempt count in TeNB S1 handover preparation success count in TeNB InterS1InSucc count S1 handover execution success count in TeNB InterS1InPrepFail_ CP_CC_TO count Preparation fails due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the inter S1 handover preparation. InterS1InPrepFail_ CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by ECCB Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Y Counter Type CC CC Trigger Type event event Data Type int int Min/Max 0-2147483647 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 120 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description block during inter S1 handover preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterS1InPrepFail_ UP_GTP_FAIL

count

Preparation fails due to internal failure in the GTP block during the inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InPrepFail_ UP_MAC_FAIL

count

Preparation fails due to internal failure in the MAC block during the inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InPrepFail_ UP_PDCP_FAIL

count

Preparation fails due to internal failure in the PDCP block during the inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InPrepFail_ UP_RLC_FAIL

count

Preparation fails due to internal failure in the RLC block during the inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InPrepFail_ CP_BH_CAC_FAIL

count

Preparation fails due to insufficient backhaul-based eNB resources during inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InPrepFail_ CP_CAPA_CAC_F AIL

count

Preparation fails due to insufficient capacity-based eNB resources during inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InPrepFail_ CP_QOS_CAC_F AIL

count

Preparation fails due to insufficient QoS-based eNB resources during inter S1 handover preparation.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 121 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name InterS1InPrepFail_ S1AP_CU_FAIL

Unit count

Description Preparation fails due to S1AP specification cause during inter S1 handover preparation.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

InterS1InPrepFail_ S1AP_LINK_FAIL

count

Preparation fails due to S1 SCTP link failure during inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InPrepFail_ S1AP_SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during inter S1 handover preparation.

CC

event

int

0-2147483647

InterS1InFail_CP_ CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_CP_ CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by ECCB block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_UP_ GTP_FAIL

count

A call is released due to the failure in the GTP block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_UP_ MAC_FAIL

count

A call is released due to the failure in the MAC block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_UP_ PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the inter

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 122 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description S1 handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterS1InFail_UP_ RLC_FAIL

count

A call is released due to the failure in the RLC block during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_RRC _HC_TO

count

A call is released due to HO command timeout (not received) during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_RRC _SIG_FAIL

count

A call is released due to receiving RRC signaling during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_S1A P_CU_FAIL

count

A call is released due to the S1AP specification cause during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_S1A P_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_S1A P_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the inter S1 handover execution.

CC

event

int

0-2147483647

InterS1InFail_S1A P_SIG_TO

count

A call is released due to S1AP signaling timeout (not received) during the inter S1 handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 123 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE Source eNB Target eNB MME S/GW

UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required Attempt Prepare Rrc Connection Reconfiguration 1 2 Handover Request Handover Request

Acknowledge Handover Command eNB Status Transfer MME Status Transfer

Rrc Connection Reconfiguration Complete Success 3 Handover Notify

Tracking Area Update Procedure (NAS) UE Context Release Command UE Context Release Complete Call Release

Figure 23. Collection Time for S1 Handover In

For inter S1 handover in statistics, when the target eNB receives the S1 Handover Request message, it is counted as Attempt; when th e target eNB transmits the S1 Handover Request Acknowledge message, it is counted as Prepare. The source eNB transmits the RRC Connection Reconfiguration message to the UE, and the target eNB receives the RRC Connection Reconfiguration Complete message fr om the UE. Success is counted after the handover is successfully completed and the S1 Handover Notify message is transmitted to the MME. When the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fails, it is counted as Inter S1 In Fail, returning the cause value.
SAMSUNG Electronics Co., Ltd. page 124 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.6

Handover Time (Average, Max)


This section provides statistics data for the average setup time and the maximum setup time of the handover interrupt time in the TeN B for each cell. Index
Name cNum scID 0~2 0~268435455 Range Cell index Source cell index Description

Type
Name IntraHOTime Unit ms Description Time taken from transmitting the RRCConnectionReconfiguratio n message to the UE until after receiving the RRCConnection ReconfigurationComplete message from the UE. IntraHOTimeM ax IntraHOTimeT ot IntraHOTimeC nt count Count of IntraHOTime collected Y GAUGE event int 0-2147483647 ms ms Average maximum intra HO interrupt time Sum of Intra HO Interrupt time Y GAUGE event float 0-3.4*10^38 Y GAUGE event float 0-60*Period*1000 max (IntraHOTimeMax) Visible Y Counter Type GAUGE Trigger Type event Data Type float Min/Max 0-60*Period*1000 Granularity Formula IntraHOTimeT ot/IntraHOTim eCnt Hourly, Daily, Monthly Formula sum (IntraHOTimeTot)/ sum (IntraHOTimeCnt)

SAMSUNG Electronics Co., Ltd.

page 125 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S1HOTime

Unit ms

Description Average S1 HO interrupt time

Visible Y

Counter Type GAUGE

Trigger Type event

Data Type float

Min/Max 0-60*Period*1000

Granularity Formula S1HOTimeTot/ S1HOTimeCnt

Hourly, Daily, Monthly Formula sum (S1HOTimeTot)/ sum (S1HOTimeCnt) max (S1HOTimeMax)

S1HOTimeMax

ms

Average maximum S1 HO interrupt time

GAUGE

event

float

0-60*Period*1000

S1HOTimeTot S1HOTimeCnt X2HOTime

ms count ms

Sum of S1 HO interrupt time Count of S1HOTime collected Average X2 HO interrupt time

Y Y Y

GAUGE GAUGE GAUGE

event event event

float int float

0-3.4*10^38 0-2147483647 0-60*Period*1000

X2HOTimeTot/ X2HOTimeCnt

sum (X2HOTimeTot)/ sum (X2HOTimeCnt) max (X2HOTimeMax)

X2HOTimeMax

ms

Average maximum X2 HO interrupt time

GAUGE

event

float

0-60*Period*1000

X2HOTimeTot X2HOTimeCnt HoTimeCnt

ms count count

Sum of X2 HO Interrupt time Count of X2HOTime collected The sum of X2 HO Interrupt time

Y Y -

GAUGE GAUGE CC

event event event

float int int

0-3.4*10^38 0-2147483647 0~2147483647

HoTimeCid

scID

Collected X2HOTime count

OW

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 126 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE UE moves to Intra eNB Cell Measurement Report HO Decision eNB

Target Cell Preparation Rrc Connection Reconfiguration


HO Time

Rrc Connection Reconfiguration Complete Internal Path Switch

Figure 24. Collection Time for Handover Time (INTRA)

SAMSUNG Electronics Co., Ltd.

page 127 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

UE

Source eNB

Target eNB

MME

S/GW

UE moves to Inter eNB Cell Measurement Report HO Decision Handover Required Handover Request Handover Request Acknowledge Handover Command Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete
HO Time

Figure 25. Collection Time for Handover Time (INTER S1)

SAMSUNG Electronics Co., Ltd.

page 128 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

UE

Source eNB

Target eNB

MME

S/GW

UE moves to Inter eNB Cell Measurement Report HO Decision Handover Request Handover Request Acknowledge Rrc Connection Reconfiguration Rrc Connection Reconfiguration Complete

HO Time

Figure 26. Collection Time for Handover Time (INTER X2)

Handover time statistics are based on the Target eNB. Intra handover time refers to the time taken from transmitting the RRC Connect ion Reconfiguration message to the UE until after receiving the RRC Connection Reconfiguration Complete message. Inter X2 handover time refers to the time taken from after transmitting the X2 Handover Request Acknowledge message at the target eNB until receivin g the RRC Connection Reconfiguration Complete message from the UE. Inter X2 handover time refers to the time taken from after tra nsmitting the S1 Handover Request Acknowledge message at the Target eNB until receiving the RRC Connection Reconfiguration Com plete message from the UE.

SAMSUNG Electronics Co., Ltd.

page 129 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.7

Outgoing Intra-Frequency Handover


If the frequency is the same between the source and target cells, handover statistics are collected. Index
Name cNum Range 0~2 Description Target Cell Index

Type
Name IntraFreqOutAtt Unit count Description Outgoing intra-frequency handover attempt count IntraFreqOutPrepS ucc IntraFreqOutSucc count count Outgoing intra-frequency handover preparation success count Outgoing intra-frequency handover execution success count IntraFreqOutPrepF ail_CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECCB or by the ECCB block during the outgoing intra-frequency handover preparation. IntraFreqOutPrepF ail_S1AP_CU_FAIL count Preparation fails due to S1AP specification cause during the outgoing intra-frequency handover Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 130 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

IntraFreqOutPrepF ail_S1AP_LINK_F AIL

count

Preparation fails due to S1 SCTP link failure during the outgoing intra-frequency handover preparation.

CC

event

int

0-2147483647

IntraFreqOutPrepF ail_S1AP_RP_TO

count

Preparation fails due to S1AP relocprep timeout (not received) during the outgoing intra-frequency handover preparation.

CC

event

int

0-2147483647

IntraFreqOutPrepFai l_S1AP_SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during the outgoing intra-frequency handover preparation.

CC

event

int

0-2147483647

IntraFreqOutPrepF ail_X2AP_CU_FAIL

count

Preparation fails due to X2AP specification cause during the outgoing intra-frequency handover preparation.

CC

event

int

0-2147483647

IntraFreqOutPrepF ail_X2AP_LINK_F AIL

count

Preparation fails due to X2 SCTP link failure during the outgoing intra-frequency handover preparation.

CC

event

int

0-2147483647

IntraFreqOutPrepF ail_X2AP_RP_TO

count

Preparation fails due to X2AP relocprep timeout (not received) during the outgoing intra-frequency handover preparation.

CC

event

int

0-2147483647

IntraFreqOutPrepFai

count

Preparation fails due to receiving

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 131 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name l_X2AP_SIG_FAIL

Unit

Description X2AP signaling during the outgoing intra-frequency handover preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

IntraFreqOutFail_ CP_CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_ CP_CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_ UP_GTP_FAIL

count

A call is released due to the failure in the GTP block during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_ UP_MAC_FAIL

count

A call is released due to the failure in the MAC block during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_ UP_PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 132 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name IntraFreqOutFail_ UP_RLC_FAIL

Unit count

Description A call is released due to the failure in the RLC block during the outgoing intra-frequency handover execution.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

IntraFreqOutFail_ RRC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_S 1AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_S 1AP_LINK_FAIL

count

A call is released due to S1 SCTP link failure during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_S 1AP_RO_TO

count

A call is released due to S1AP relocoverall timeout (not received) during the outgoing intrafrequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_S 1AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_X 2AP_CU_FAIL

count

A call is released due to the X2AP specification cause during the

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 133 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description outgoing intra-frequency handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

IntraFreqOutFail_X 2AP_LINK_FAIL

count

A call is released due to X2 SCTP link failure during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_X 2AP_RO_TO

count

A call is released due to X2AP RelocOverall timeout (not received) during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

IntraFreqOutFail_X 2AP_SIG_FAIL

count

A call is released due to receiving the X2AP signaling during the outgoing intra-frequency handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 134 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.8

Outgoing Inter-frequency Handover with Measurement Gap


The handover statistics is collected if the frequency information between source and target is different and measurement gap is used. Index
Name cNum TargetEarfcnDl 0~2 0~268435455 Range Target Cell Index Target neighbor cell frequency (EARFCN DL) Description

Type
Name InterFreqMeasGap OutAtt Unit count Description Outgoing inter-frequency handover (measurement gap assisted) attempt count InterFreqMeasGap OutPrepSucc count Outgoing inter-frequency handover (measurement gap assisted) preparation success count InterFreqMeasGap OutSucc count Outgoing inter-frequency handover (measurement gap assisted) execution success count InterFreqMeasGap OutPrepFail_CP_C C_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECCB or by the ECCB block during the outgoing interfrequency handover (measurement Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 135 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description gap assisted) preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqMeasGap OutPrepFail_S1AP _CU_FAIL

count

Preparation fails due to the S1AP specification cause during the outgoing inter-frequency handover (measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqMeasGap OutPrepFail_S1AP _LINK_FAIL

count

Preparation fails due to the S1 SCTP link failure during the outgoing inter-frequency handover (measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqMeasGap OutPrepFail_S1AP _RP_TO

count

Preparation fails due to S1AP relocprep timeout (not received) during the outgoing inter-frequency handover (measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqMeasGap OutPrepFail_S1AP _SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during the outgoing inter-frequency handover (measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqMeasGap OutPrepFail_X2AP _CU_FAIL

count

Preparation fails due to the X2AP specification cause during the outgoing inter-frequency handover (measurement gap assisted) preparation.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 136 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name InterFreqMeasGap OutPrepFail_X2AP _LINK_FAIL

Unit count

Description Preparation fails due to the X2 SCTP link failure during the outgoing inter-frequency handover (measurement gap assisted) preparation.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

InterFreqMeasGap OutPrepFail_X2AP _RP_TO

count

Preparation fails due to X2AP relocprep timeout (not received) during the outgoing inter-frequency handover (measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqMeasGap OutPrepFail_X2AP _SIG_FAIL

count

Preparation fails due to receiving X2AP signaling during the outgoing inter-frequency handover (measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqMeasGapO utFail_CP_CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_CP_CC_F AIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the outgoing interfrequency handover (measurement

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 137 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description gap assisted) execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqMeasGap OutFail_UP_GTP_ FAIL

count

A call is released due to the failure in the GTP block during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_UP_MAC_ FAIL

count

A call is released due to the failure in the MAC block during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_UP_PDCP _FAIL

count

A call is released due to the failure in the PDCP block during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_UP_RLC_ FAIL

count

A call is released due to the failure in the RLC block during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_RRC_SIG _FAIL

count

A call is released due to receiving RRC signaling during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 138 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name InterFreqMeasGap OutFail_S1AP_CU _FAIL

Unit count

Description A call is released due to the S1AP specification cause during the outgoing inter-frequency handover (measurement gap assisted) execution.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

InterFreqMeasGap OutFail_S1AP_LIN K_FAIL

count

A call is released due to the S1 SCTP link failure during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_S1AP_RO _TO

count

A call is released due to the S1AP relocoverall timeout (not received) during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_S1AP_SIG _FAIL

count

A call is released due to receiving S1AP signaling during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_X2AP_CU _FAIL

count

A call is released due to the X2AP specification cause during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap

count

A call is released due to the X2

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 139 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name OutFail_X2AP_LIN K_FAIL

Unit

Description SCTP link failure during the outgoing inter-frequency handover (measurement gap assisted) execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqMeasGap OutFail_X2AP_RO _TO

count

A call is released due to the X2AP relocoverall timeout (not received) during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqMeasGap OutFail_X2AP_SIG _FAIL

count

A call is released due to receiving X2AP signaling during the outgoing inter-frequency handover (measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqOutWithG apCnt

count

Outgoing Inter-Frequency Handover (measurement gap assisted) collection count

CC

event

int

0~2147483647

InterFreqOutWithG apTargetEarfcnDl

Target Earfc nDl

TargetEarfcnDl of which collection is requested

OW

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 140 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.9

Outgoing Inter-frequency Handover without Measurement Gap


The handover statistics are collected if the frequency is different between the source and target cells, and measurement gap is not used. Index
Name cNum TargetEarfcnDl 0~2 0~268435455 Range Target Cell Index Target neighbor cell frequency (EARFCN DL) Description

Type
Name InterFreqNoMeasGa pOutAtt Unit count Description Outgoing inter-frequency handover (no measurement gap assisted) attempt count InterFreqNoMeasGa pOutPrepSucc count Outgoing inter-frequency handover (no measurement gap assisted) preparation success count InterFreqNoMeasGa pOutSucc count Outgoing inter-frequency handover (no measurement gap assisted) execution success count InterFreqNoMeasGa pOutPrepFail_CP_C C_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECCB or by the Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 141 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description ECCB block during the outgoing inter-frequency handover (no measurement gap assisted) preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqNoMeasGa pOutPrepFail_S1AP _CU_FAIL

count

Preparation fails due to the S1AP specification cause during the outgoing inter-frequency handover (no measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutPrepFail_S1AP _LINK_FAIL

count

Preparation fails due to the S1 SCTP link failure during the outgoing inter-frequency handover (no measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutPrepFail_S1AP _RP_TO

count

Preparation fails due to S1AP relocprep timeout (not received) during the outgoing interfrequency handover (no measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutPrepFail_S1AP _SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during the outgoing inter-frequency handover (no measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqNoMeasGa

count

Preparation fails due to the

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 142 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name pOutPrepFail_X2AP _CU_FAIL

Unit

Description X2AP specification cause during the outgoing inter-frequency handover (no measurement gap assisted) preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqNoMeasGa pOutPrepFail_X2AP _LINK_FAIL

count

Preparation fails due to the X2 SCTP link failure during the outgoing inter-frequency handover (no measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutPrepFail_X2AP _RP_TO

count

Preparation fails due to X2AP relocprep timeout (not received) during the outgoing interfrequency handover (no measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutPrepFail_X2AP _SIG_FAIL

count

Preparation fails due to receiving X2AP signaling during the outgoing inter-frequency handover (no measurement gap assisted) preparation.

CC

event

int

0-2147483647

InterFreqNoMeasGap OutFail_CP_CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the outgoing interfrequency handover (no measurement gap assisted)

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 143 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit execution.

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqNoMeasGa pOutFail_CP_CC_F AIL

count

A call is released due to reset notification (eNB failure or bloc restart) from ECMB or by the ECCB block during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_UP_GTP_ FAIL

count

A call is released due to the failure in the GTP block during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_UP_MAC_ FAIL

count

A call is released due to the failure in the MAC block during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_UP_PDCP _FAIL

count

A call is released due to the failure in the PDCP block during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_UP_RLC_ FAIL

count

A call is released due to the failure in the RLC block during the outgoing inter-frequency

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 144 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description handover (no measurement gap assisted) execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqNoMeasGa pOutFail_RRC_SIG _FAIL

count

A call is released due to receiving RRC signaling during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_S1AP_CU _FAIL

count

A call is released due to the S1AP specification cause during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_S1AP_LIN K_FAIL

count

A call is released due to the S1 SCTP link failure during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_S1AP_RO _TO

count

A call is released due to the S1AP relocoverall timeout (not received) during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_S1AP_SIG _FAIL

count

A call is released due to receiving S1AP signaling during the outgoing inter-frequency

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 145 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description handover (no measurement gap assisted) execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

InterFreqNoMeasGa pOutFail_X2AP_CU _FAIL

count

A call is released due to the X2AP specification cause during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_X2AP_LIN K_FAIL

count

A call is released due to the X2 SCTP link failure during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_X2AP_RO _TO

count

A call is released due to the X2AP relocoverall timeout (not received) during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqNoMeasGa pOutFail_X2AP_SIG _FAIL

count

A call is released due to receiving X2AP signaling during the outgoing inter-frequency handover (no measurement gap assisted) execution.

CC

event

int

0-2147483647

InterFreqOutWithOu tGapCnt

count

Outgoing Inter-Frequency Handover (No measurement gap assisted) collection count

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 146 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name InterFreqOutWithOu tGapTargetEarfcnDl

Unit Target Earfcn Dl

Description TargetEarfcnDl of which collection is requested

Visible

Counter Type OW

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 147 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.10 Outgoing Handover with DRX


The handover statistics are collected when DRX is set for the UE. Index
Name cNum Range 0~2 Description Target Cell Index

Type
Name DrxOutAtt Unit count Description Outgoing handover (with DRX) attempt count DrxOutPrepSucc count Outgoing handover (with DRX) preparation success count DrxOutSucc count Outgoing handover (with DRX) execution success count DrxOutPrepFail_ CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECCB or by the ECCB block during the outgoing handover (with DRX) preparation. DrxOutPrepFail_ S1AP_CU_FAIL count Preparation fails due to S1AP specification cause during the outgoing handover (with DRX) preparation. DrxOutPrepFail_ S1AP_LINK_FAI count Preparation fails due to the S1 SCTP link failure during the outgoing handover Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 148 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name L DrxOutPrepFail_ S1AP_RP_TO

Unit

Description (with DRX) preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Preparation fails due to S1AP relocprep timeout (not received) during the outgoing handover (with DRX) preparation.

CC

event

int

0-2147483647

DrxOutPrepFail_ S1AP_SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during the outgoing handover (with DRX) preparation.

CC

event

int

0-2147483647

DrxOutPrepFail_ X2AP_CU_FAIL

count

Preparation fails due to X2AP specification cause during the outgoing handover (with DRX) preparation.

CC

event

int

0-2147483647

DrxOutPrepFail_ X2AP_LINK_FAI L DrxOutPrepFail_ X2AP_RP_TO

count

Preparation fails due to the X2 SCTP link failure during the outgoing handover (with DRX) preparation.

CC

event

int

0-2147483647

count

Preparation fails due to X2AP relocprep timeout (not received) during the outgoing handover (with DRX) preparation.

CC

event

int

0-2147483647

DrxOutPrepFail_ X2AP_SIG_FAIL

count

Preparation fails due to receiving X2AP signaling during the outgoing handover (with DRX) preparation.

CC

event

int

0-2147483647

DrxOutFail_CP_ CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 149 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DrxOutFail_CP_ CC_FAIL

Unit count

Description A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the outgoing handover (with DRX) execution.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DrxOutFail_UP_ GTP_FAIL

count

A call is released due to the failure in the GTP block during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_UP_ MAC_FAIL

count

A call is released due to the failure in the MAC block during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_UP_ PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_UP_ RLC_ FAIL DrxOutFail_RRC _SIG_FAIL

count

A call is released due to the failure in the RLC block during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

count

A call is released due to receiving RRC signaling during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_S1A P_CU_FAIL

count

A call is released due to the S1AP specification cause during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_S1A P_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 150 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DrxOutFail_S1A P_RO_TO

Unit count

Description A call is released due to S1AP relocoverall timeout (not received) during the outgoing handover (with DRX) execution.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DrxOutFail_S1A P_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_X2A P_CU_FAIL

count

A call is released due to the X2AP specification cause during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_X2A P_LINK_FAIL

count

A call is released due to the X2 SCTP link failure during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_X2A P_RO_TO

count

A call is released due to X2AP RelocOverall timeout (not received) during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

DrxOutFail_X2A P_SIG_FAIL

count

A call is released due to receiving X2AP signaling during the outgoing handover (with DRX) execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 151 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

5.11 Outgoing Handover without DRX


The handover statistics is collected when DRX is not set on the UE. Index
Name cNum Range 0~2 Description Target Cell Index

Type
Name NoDrxOutAtt Unit count Description Outgoing handover (without DRX) attempt count NoDrxOutPrepSu cc NoDrxOutSucc count count Outgoing handover (without DRX) preparation success count Outgoing handover (without DRX) execution success count NoDrxOutPrepFa il_CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the outgoing handover (without DRX) preparation. NoDrxOutPrepFail _S1AP_CU_FAIL count Preparation fails due to S1AP specification cause during the outgoing handover (without DRX) Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 152 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

NoDrxOutPrepFa il_S1AP_LINK_F AIL

count

Preparation fails due to the S1 SCTP link failure during the outgoing handover (without DRX) preparation.

CC

event

int

0-2147483647

NoDrxOutPrepFa il_S1AP_RP_TO

count

Preparation ails due to S1AP relocprep timeout (not received) during the outgoing handover (without DRX) preparation.

CC

event

int

0-2147483647

NoDrxOutPrepFa il_S1AP_SIG_FA IL

count

Preparation fails due to receiving S1AP signaling during the outgoing handover (without DRX) preparation.

CC

event

int

0-2147483647

NoDrxOutPrepFail _X2AP_CU_FAIL

count

Preparation fails due to X2AP specification cause during the outgoing handover (without DRX) preparation.

CC

event

int

0-2147483647

NoDrxOutPrepFa il_X2AP_LINK_F AIL

count

Preparation fails due to the X2 SCTP link failure during the outgoing handover (without DRX) preparation.

CC

event

int

0-2147483647

NoDrxOutPrepFa il_X2AP_RP_TO

count

Preparation fails due to X2AP relocprep timeout (not received) during the outgoing handover (without DRX) preparation.

CC

event

int

0-2147483647

NoDrxOutPrepFa

count

Preparation fails due to receiving

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 153 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name il_X2AP_SIG_FA IL

Unit

Description X2AP signaling during the outgoing handover (without DRX) preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

NoDrxOutFail_C P_CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_C P_CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_U P_GTP_FAIL

count

A call is released due to the failure in the GTP block during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_U P_MAC_FAIL

count

A call is released due to the failure in the MAC block during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_U P_PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_U

count

A call is released due to the failure

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 154 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name P_RLC_FAIL

Unit

Description in the RLC block during the outgoing handover (without DRX) execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

NoDrxOutFail_R RC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_S1 AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_S1 AP_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_S1 AP_RO_TO

count

A call is released due to S1AP relocoverall timeout (not received) during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_S1 AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_X2 AP_CU_FAIL

count

A call is released due to the X2AP specification cause during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_X2

count

A call is released due to the X2

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 155 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name AP_LINK_FAIL

Unit

Description SCTP link failure during the outgoing handover (without DRX) execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

NoDrxOutFail_X2 AP_RO_TO

count

A call is released due to X2AP RelocOverall timeout (not received) during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

NoDrxOutFail_X2 AP_SIG_FAIL

count

A call is released due to receiving X2AP signaling during the outgoing handover (without DRX) execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 156 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

HO UTRAN
Inter-RAT UTRAN PS Handover: Inter-RAT UTRAN PS Handover Out, InterRAT UTRAN PS Handover In This section provides statistics data for handover between the LTE system and UTR AN system for each cell. The following shows the message flow for the PS hando ver procedure from the E-UTRAN to the UTRAN.

UE

Source eNB

Target RNS

Source MME Source S-GW Target SGSN

Target S-GW

P-GW

Downlink/Uplink data 1) Handover Initiation

Downlink/Uplink data

Downlink/Uplink data

2) HANDOVER REQUIRED 3) FORWARD RELOCATION REQUEST 4) Create Session 5) RELOCATION REQUEST 6) RELOCATION REQUEST ACKNOWLEDGE 7) Create Indirect Data 8) FORWARD RELOCATION RESPONSE 9) Create Indirect Data 10) HANDOVER COMMAND 11) Mobility from EUTRAN Command Indirect data forwarding Indirect data forwarding 12) HO to UTRAN Complete 13) RELOCATION COMPLETE 14) FORWARD RELOCATION COMPLETE NOTIFICATION 15) FORWARD RELOCATION COMPLETE ACKNOWLEDGE 16) MODIFY BEARER 17) Modify Bearer REQUEST 18) MODIFY BEARER Downlink/Uplink data Downlink/Uplink data RESPONSE Request/Response Forwarding Tunnel Request/Response Forwarding Tunnel Request/Response Request/Response

Downlink/Uplink data

19) Routing Area Update procedure 20) S1 Release

21) Delete Session Request/Response 22) Create Indirect Data Forwarding Tunnel Request/Response 23) Create Indirect Data Forwarding Tunnel Request/Response

Figure 27. PS Handover Procedure from E-UTRAN to UTRAN

SAMSUNG Electronics Co., Ltd.

page 157 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Step 1)

Description The source eNB determines the PS handover to the UTRAN. This decision is made according to the measurement report received from the UE.

2)

The source eNB transmits the HANDOVER REQUIRED message to the MME. The source eNB then includes the source RNC to target RNC transparent container IE information in the message for relaying the necessary information to the target RNC.

3)-4)

The source MME recognizes the handover from the target ID IE of the HANDOVER REQUIRED message to the UTRAN and transmits the FORWARD RELOCATION REQUEST message to the target SGSN. The target SGSN determines whether to change the S-GW. If change is required, it carries out the Create Session Request/Response procedure with a new S-GW.

5)-6)

The target SGSN transmits the RELOCATION REQUEST message to the target RNC to request resource allocation for the target RNC. The target RNC performs CAC and resource allocation for each RAB for which handover is requested, and transmits to the target SGSN the RELOCATION REQUEST ACKNOWLEDGE message that encapsulates the result. The RELOCATION REQUEST ACKNOWLEDGE message encapsulates the Target RNC to Source RNC Transparent Container IE to be transmitted to the source eNB.

7)-9)

To perform the forwarding tunnel setup, the target SGSN performs the Create Indirect Data Forwarding Tunnel Request/Response procedure with target S-GW and transmits the FORWARD RELOCATION RESPONSE message to the source MME. To perform the forwarding tunnel setup, the source MME carries out the Create Indirect Data Forwarding Tunnel Request/Response procedure with the source S-GW.

10)-11)

The source MME transmits the HANDOVER COMMAND message to the source eNB to complete the handover preparation procedure to the target UTRAN. The source eNB configures the MOBILITY FROM E-UTRAN COMMAND containing the Target RNC to Source RNC Transparent Container IE in the HANDOVER COMMAND message and transmits it to the UE to request the PS handover to the UTRAN.

12)

The UE performs synchronization with the target UTRAN and connects to the target cell via the RACH. After UE is successfully connected to the target cell, UE transmits the HANDOVER TO UTRAN COMPLETE message to the target UTRAN to complete the handover procedure.

13)-15)

The target RNC transmits the RELOCATION COMPLETE message to the target SGSN to notify that the handover procedure from the UE to the UTRAN has been completed successfully. The target SGSN transmits the FORWARD RELOCATION COMPLETE NOTIFICATION message to the source MME. At this time, the source MME operates the waiting timer for releasing the resource of the E-UTRAN and transmits the FORWARD RELOCATION COMPLETE ACKNOWLEDGE response message to the target SGSN. The target SGSN operates the waiting timer for releasing the forwarding tunnel at the time when the source MME receives the response message.

16)-18)

The target SGSN transmits the Modify Bearer Request message for each PDN connection to the target S-GW. Subsequent downlink packets are then transmitted from

SAMSUNG Electronics Co., Ltd.

page 158 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Step

Description the S-GW to the target RNC. The target S-GW performs the Modify Bearer Request/Response procedure with the P-GW and transmits the Modify Bearer Response message to the target SGSN.

19)

When UE satisfies the conditions specified in section 5.5.2.1 of TS 23.401, the Routing Area Update procedure starts.

20)-23)

When the timer at Step 14) expires, the source MME requests the source eNB and the source S-GW to release the resources. When the timer at Step 15) expires, the target SGSN releases the resources release allocated for forwarding tunnel with the target SGW.

SAMSUNG Electronics Co., Ltd.

page 159 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

6.1

Inter-RAT UTRAN PS Handover OUT


This section provides statistics data for outgoing handover between the LTE and UTRAN systems for each cell. The collection time for HO attempt, HO preparation and HO success statistics is the same as that for S1 handover out statistics. Index
Name cNum HOCause 0~2 0~1 Range Source Cell Index Handover cause 0: Handover desirable for radio reasons 1: reserved Description

Type
Name RatOutAttUTRAN Unit count Description LTE to inter-RAT UTRAN handover attempt count. RatOutPrepSuccUT RAN RatOutSuccUTRAN count count LTE to inter-RAT UTRAN handover preparation success count LTE to inter-RAT UTRAN handover execution success count RatOutPrepFailUTR AN_CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation. Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 160 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RatOutPrepFailUTR AN_S1AP_CU_FAI L RatOutPrepFailUTR AN_S1AP_LINK_F AIL RatOutPrepFailUTR AN_S1AP_RP_TO

Unit count

Description Preparation fails due to S1AP specification cause during the UTRAN handover preparation.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Preparation fails due to S1 SCTP link failure during the UTRAN handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatOutPrepFailUTR AN_S1AP_SIG_FAI L RatOutFailUTRAN_ CP_CC_TO

count

Preparation fails due to receiving S1AP signaling during the UTRAN handover preparation.

CC

event

int

0-2147483647

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN handover execution.

CC

event

int

0-2147483647

RatOutFailUTRAN_ CP_CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatOutFailUTRAN_ UP_GTP_FAIL

count

A call is released due to the failure in the GTP block during the UTRAN handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 161 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RatOutFailUTRAN_ UP_MAC_FAIL

Unit count

Description A call is released due to the failure in the MAC block during the UTRAN handover execution.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RatOutFailUTRAN_ UP_PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the UTRAN handover execution.

CC

event

int

0-2147483647

RatOutFailUTRAN_ UP_RLC_FAIL

count

A call is released due to the failure in the RLC block during the UTRAN handover execution.

CC

event

int

0-2147483647

RatOutFailUTRAN_ RRC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the UTRAN handover execution.

CC

event

int

0-2147483647

RatOutFailUTRAN_ S1AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the UTRAN handover execution.

CC

event

int

0-2147483647

RatOutFailUTRAN_ S1AP_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the UTRAN handover execution.

CC

event

int

0-2147483647

RatOutFailUTRAN_ S1AP_RO_TO

count

A call is released due to S1AP relocoverall timeout (not received) during the UTRAN handover execution.

CC

event

int

0-2147483647

RatOutFailUTRAN_ S1AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the UTRAN handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 162 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE Source eNB MME

Measurement Report

HO Decision

Attempt Handover Required Handover Command

2 Prepare Mobility From EUTRA Command

UE Context Release Command UE Context Release Complete

Call Release

3 Success

Figure 28. Collection Time for Inter-RAT UTRAN PS Handover Out

For inter-RAT UTRAN Handover Out statistics, Attempt is counted when the S1 Handover Required message is transmitted after the U TRAN handover decision following the Measurement Report message arrival, and Prepare is counted when the Mobility Eutra Comman d message is transmitted to the UE. Success is counted when the handover is completed and the MME transmits the UE Context Rele ase Complete message. If the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fai ls, it is counted as Inter RAT UTRAN HO Out Fail, returning the cause value.

SAMSUNG Electronics Co., Ltd.

page 163 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

6.2

Inter-RAT UTRAN PS Handover IN


This section provides statistics data for handover between the LTE system and UTRAN system for each cell. Index
Name cNum HOCause 0~2 0~1 Range Source Cell Index Handover cause 0: Handover desirable for radio reasons 1: reserved Description

Type
Name RatInAttUTRAN Unit count Description Inter-RAT UTRAN to LTE handover attempt count RatInPrepSuccUT RAN RatInSuccUTRAN count count Inter-RAT UTRAN to LTE handover preparation success count. Inter-RAT UTRAN to LTE handover execution success count. RatInPrepFailUTR AN_CP_CC_TO count Preparation fails due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN handover preparation. RatInPrepFailUTR AN_CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 164 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description restart) from ECMB or by the ECCB block during the UTRAN handover preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RatInPrepFailUTRA N_UP_GTP_FAIL

count

Preparation fails due to internal failure in the GTP block during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatInPrepFailUTRA N_UP_MAC_FAIL

count

Preparation fails due to internal failure in the MAC block during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatInPrepFailUTR AN_UP_PDCP_FA IL RatInPrepFailUTRA N_UP_RLC_FAIL

count

Preparation fails due to internal failure in the PDCP block during the UTRAN handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to internal failure in the RLC block during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatInPrepFailUTR AN_CP_BH_CAC _FAIL

count

Preparation fails due to insufficient backhaul-based eNB resources during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatInPrepFailUTR AN_CP_CAPA_CA C_FAIL

count

Preparation fails due to insufficient capacity-based eNB resources during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatInPrepFailUTR AN_CP_QOS_CA C_FAIL

count

Preparation fails due to insufficient QoS-based eNB resources during the UTRAN handover preparation.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 165 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RatInPrepFailUTR AN_S1AP_CU_FA IL RatInPrepFailUTR AN_S1AP_LINK_F AIL RatInPrepFailUTR AN_S1AP_SIG_F AIL RatInFailUTRAN_ CP_CC_TO

Unit count

Description Preparation fails due to S1AP specification cause during the UTRAN handover preparation.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Preparation fails due to S1 SCTP link failure during the UTRAN handover preparation.

CC

event

int

0-2147483647

count

Preparation fails due to receiving S1AP signaling during the UTRAN handover preparation.

CC

event

int

0-2147483647

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ CP_CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN handover preparation.

CC

event

int

0-2147483647

RatInFailUTRAN_ UP_GTP_FAIL

count

A call is released due to the failure in the GTP block during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ UP_MAC_FAIL

count

A call is released due to the failure in the MAC block during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ UP_PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 166 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description UTRAN handover execution.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RatInFailUTRAN_ UP_RLC_FAIL

count

A call is released due to the failure in the RLC block during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ RRC_HC_TO

count

A call is released due to HO command timeout (not received) during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ RRC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ S1AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ S1AP_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ S1AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the UTRAN handover execution.

CC

event

int

0-2147483647

RatInFailUTRAN_ S1AP_SIG_TO

count

A call is released due to S1AP signaling timeout (not received) during the UTRAN handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 167 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time

UE

Target eNB

MME

Attempt

Handover Request

Prepare

Handover Request Acknowledge

RRC Connection Reconfiguration Complete (Handover to E-UTRAN Complete) Handover Notify

Success

Figure 29. Collection Time for Inter-RAT UTRAN PS Handover In

For Inter-RAT UTRAN In statistics, Attempt is counted when the target eNB receives the S1 Handover Request message, and Prepare is counted after the target eNB transmits the S1 Handover Request Acknowledge message. The target eNB receives the RRC Connectio n Reconfiguration Complete message from the UE. Success is counted after the handover is successfully completed and the S1 Handov er Notify message is transmitted to the MME. If the procedure from to fails, it is counted as Prepare Fail, returning the cause v alue, and when the procedure from to fails, it is counted as Inter RAT UTRAN In Fail, returning the cause value.

SAMSUNG Electronics Co., Ltd.

page 168 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

6.3

UTRAN SRVCC
This section provides statistics data for SRVCC handover to UTRAN. Index
Name cNum HOCause 0~2 0~1 Range Source Cell Index Handover Cause 0: handover desirable for radio reasons 1: reserved HOIndication 0~1 Description

Type
Name UtranSrvccOutAtt Unit count Description UTRAN SRVCC Handover attempt count UtranSrvccOutPrepSu cc UtranSrvccOutSucc count count UTRAN SRVCC Handover preparation success count UTRAN SRVCC Handover execution success count UtranSrvccOutPrepFai l_CP_CC_FAIL count Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC preparation. Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 169 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UtranSrvccOutPrepFai l_S1AP_CU_FAIL

Unit count

Description Preparation fails due to S1AP specification cause during the UTRAN SRVCC preparation

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UtranSrvccOutPrepFai l_S1AP_LINK_FAIL

count

Preparation fails due to S1 SCTP link failure during the UTRAN SRVCC preparation.

CC

event

int

0~2147483647

UtranSrvccOutPrepFai l_S1AP_RP_TO

count

Preparation fails due to S1AP relocprep timeout (not received) during the UTRAN SRVCC preparation.

CC

event

int

0~2147483647

UtranSrvccOutPrepFai l_S1AP_SIG_FAIL

count

Preparation fails due to receiving S1AP signaling during the UTRAN SRVCC preparation

CC

event

int

0~2147483647

UtranSrvccOutFail_CP _CC_TO

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_CP _CC_FAIL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_UP _GTP_FAIL

count

A call is released due to the failure in the GTP block during the UTRAN SRVCC execution

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 170 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UtranSrvccOutFail_UP _MAC_FAIL

Unit count

Description A call is released due to the failure in the MAC block during the UTRAN SRVCC execution

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UtranSrvccOutFail_UP _PDCP_FAIL

count

A call is released due to the failure in the PDCP block during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_UP _RLC_FAIL

count

A call is released due to the failure in the RLC block during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_R RC_SIG_FAIL

count

A call is released due to receiving RRC signaling during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_S1 AP_CU_FAIL

count

A call is released due to the S1AP specification cause during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_S1 AP_LINK_FAIL

count

A call is released due to the S1 SCTP link failure during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_S1 AP_RO_TO

count

A call is released due to S1AP relocoverall timeout (not received) during the UTRAN SRVCC execution

CC

event

int

0~2147483647

UtranSrvccOutFail_S1 AP_SIG_FAIL

count

A call is released due to receiving S1AP signaling during the UTRAN SRVCC execution

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 171 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

6.4

CS Fall Back (CSFB) PS Handover OUT


This section provides statistics for CSFB with PS handover count between the LTE and UTRAN for each cell.
Steps 1 1b, 1c Description The UE transmits the Extended Service Request message to the MME through the NAS procedure. If the CS Fallback indicator is encapsulated in the Initial Context Setup Request and UE Context Modification Request, the eNB transmits the Initial Context Setup Response and UE Context Modification Response message to the MME, and prepares for CS fallback. 2 The RRC Connection Reconfiguration message that encapsulates the periodic report information is transmitted to the UE; and handover procedure starts when the periodic measurement report is received. 3 The procedure after this is the same as that of inter-RAT handover-LTE to UTRAN PS handover.

Index
Name cNum CSFBIndicator 0~2 0~1 Range Source Cell Index CSFB Indicator 0: Normal 1: High priority Description

SAMSUNG Electronics Co., Ltd.

page 172 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Type
Name CsfbPsHoAttUTR AN CsfbPsHoPrepSu ccUTRAN count Unit count Description Attempt count for CSFB with interRAT UTRAN PS handover. Success count for CSFB with interRAT UTRAN PS handover preparation. CsfbPsHoSuccUT RAN CsfbPsHoPrepFai lUTRAN_CP_CC _FAIL count count Success count for CSFB with interRAT UTRAN PS handover execution. Preparation fails due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the CSFB PS handover preparation. CsfbPsHoPrepFai lUTRAN_S1AP_C U_FAIL CsfbPsHoPrepFai lUTRAN_S1AP_L INK_FAIL CsfbPsHoPrepFai lUTRAN_S1AP_R P_TO count count count Preparation fails due to S1AP specification cause during the CSFB PS handover preparation. Preparation fails due to S1 SCTP link failure during the CSFB PS handover preparation. Preparation fails due to S1AP relocprep timeout (not received) during the CSFB PS handover preparation. CsfbPsHoPrepFai lUTRAN_S1AP_S count Preparation fails due to receiving S1AP signaling during the CSFB Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 173 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name IG_FAIL CsfbPsHoFailUT RAN_CP_CC_TO

Unit

Description PS handover preparation.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

A call is released due to call control timeout in the protocol blocks (MAC, RLC, PDCP, GTP) during the CSFB PS handover execution.

CC

event

int

0-2147483647

CsfbPsHoFailUT RAN_CP_CC_FA IL

count

A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during the CSFB PS handover execution.

CC

event

int

0-2147483647

CsfbPsHoFailUT RAN_UP_GTP_F AIL CsfbPsHoFailUT RAN_UP_MAC_F AIL CsfbPsHoFailUT RAN_UP_PDCP_ FAIL CsfbPsHoFailUT RAN_UP_RLC_F AIL CsfbPsHoFailUT RAN_RRC_SIG_ FAIL

count

A call is released due to the failure in the GTP block during the CSFB PS handover execution.

CC

event

int

0-2147483647

count

A call is released due to the failure in the MAC block during the CSFB PS handover execution.

CC

event

int

0-2147483647

count

A call is released due to the failure in the PDCP block during the CSFB PS handover execution.

CC

event

int

0-2147483647

count

A call is released due to the failure in the RLC block during the CSFB PS handover execution.

CC

event

int

0-2147483647

count

A call is released due to receiving RRC signaling during the CSFB PS handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 174 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name CsfbPsHoFailUT RAN_S1AP_CU_ FAIL CsfbPsHoFailUT RAN_S1AP_LINK _FAIL CsfbPsHoFailUT RAN_S1AP_RO_ TO

Unit count

Description A call is released due to the S1AP specification cause during the CSFB PS handover execution.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

A call is released due to the S1 SCTP link failure during the CSFB PS handover execution.

CC

event

int

0-2147483647

count

A call is released due to S1AP relocoverall timeout (not received) during the CSFB PS handover execution.

CC

event

int

0-2147483647

CsfbPsHoFailUT RAN_S1AP_SIG_ FAIL

count

A call is released due to receiving S1AP signaling during the CSFB PS handover execution.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 175 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE Source eNB
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Solicit Measurement Report Handover Required

MME

1 Attempt

Handover Command

Mobility From EUTRA Command

2 Prepare

UE Context Release Command

3 Success

UE Context Release Complete

Call Release

Figure 30. Collection Time for CSFB PS Handover Out

For CSFB PS handover UTRAN out statistics, when the S1 Handover Required message can be transmitted to the MME after the han dover UTRAN decision following the Measurement Report message arrival, it is counted as Attempt; when the S1 Handover Command message is received from the MME, it is counted as Prepare. The source eNB transmits the Mobility From EUTRA Command messa ge to the UE, and the MME transmits the S1 UE Context Release Command message to the source eNB. At this point, the source eN B is counted as Success. If the procedure from to fails, it is counted as Prepare Fail, returning the cause value, and when the procedure from to fai ls, it is counted as CSFB PS HO UTRAN Out, returning the cause value.

SAMSUNG Electronics Co., Ltd.

page 176 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

6.5

CS FallBack (CSFB) without PS Handover Out (Redirection)


This section provides statistics for CSFB with Redirection count between the LTE and UTRAN for each cell. Index
Name cNum CSFBIndicator 0~2 0~1 Range Source Cell Index CSFB Indicator 0: Normal 1: High priority SIBOwn 0~1 Indicates whether UTRAN SI information is included. 0: Not included 1: Included Description

Type
Name CsfbRedirAttUTRAN Unit count Description CSFB with Redirection to interRAT UTRAN attempt count CsfbRedirPrepSuc cUTRAN count CSFB with Redirection to interRAT UTRAN preparation success count. CsfbRedirSuccUT RAN count CSFB with Redirection to interRAT UTRAN execution success count. Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 177 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE Source eNB
Initial Context Setup Request (with CSFB Ind) or UE Context Modification Request (with CSFB Ind) Initial Context Setup Response

MME

1 Attempt

1 1

or UE Context Modification Response Redirection

2 Prepare
RRC connection Release (with Redirection Info)

3 Success

Call Release

Figure 31. Collection Time for CSFB Redirection Out

For CSFB with Redirection UTRAN statistics, when the Initial Context Setup Request or UE Context Modification Request message re ceived has the CSFB Indicator IE, according to which CSFB is decided, it is counted as Attempt; when preparation is completed in th e eNB, it is counted as Prepare. Success is counted when the RRC Connection Release message is transmitted to the UE for redirectio n.

SAMSUNG Electronics Co., Ltd.

page 178 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

6.6

PS Redirection UTRAN Out


Collects statistics data for PS redirection between the LTE system and UTRAN for each cell. Index
Name cNum HOCause 0~2 0~1 Range Source Cell Index Handover Cause 0: handover desirable for radio reasons 1: reserved Description

Type
Name PsRedirAttUTRAN Unit count Description PS Redirection to Inter RAT UTRAN attempt count PsRedirPrepSuccUT RAN count PS Redirection to Inter RAT UTRAN preparation success count PsRedirSuccUTRAN count PS Redirection to Inter RAT UTRAN execution success count Y CC event int 0~2147483647 Y CC event int 0~2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 179 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

CSL
Call Summary Log (CSL) is counted when the call is dropped. It can be used to collect various information and actual release cause f or the call for example Call Release Cause. These statistics items are described in the following table.

7.1

Call Fail Report


This section provides statistics data for the CSL. The CSL statistics are collected when the call is released, and can help identify the a ctual cause of the call release. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name No_FAULT S1AP_CauseRadioN etwork_unspecified Unit count count Description The call is terminated normally. During handover, the target eNB transmits the Path Switch Request message, and then does not receive the Path Switch Response, but receives the UE Context Release Command message. S1AP_tx2relocoveral count Currently not in use. Y CC event int 0-2147483647 Visible Y Y Counter Type CC CC Trigger Type event event Data Type int int Min/Max 0-2147483647 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 180 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name l_expiry S1AP_successful_h andover S1AP_release_due_ to_eutran_generated _reason S1AP_handover_ca ncelled S1AP_partial_hando ver S1AP_ho_failure_in _target_EPC_eNB_o r_target_system

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Currently not in use.

CC

event

int

0-2147483647

count

A call is released due to redirection when MR is received from the UE.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

When a failure cause is received from target system as the Forward Relocation Response during InterMME/Inter-RAT S1 handover, it is transmitted by being specified in the Handover Preparation Failure.

CC

event

int

0-2147483647

S1AP_ho_target_not _allowed

count

If S1 handover fails due to AccessRestriction (Utran Not Allow, etc.) of the UE, it is transmitted by being specified in the Handover Preparation Failure.

CC

event

int

0-2147483647

S1AP_tS1relocovera ll_expiry S1AP_tS1relocprep_ expiry

count

Currently not in use.

CC

event

int

0-2147483647

count

In S1_OUT statistics event, when the timer waiting for the handover

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 181 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description command expires after the source eNB transmits the Handover Required message.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

S1AP_cell_not_avail able S1AP_unknown_tar getID

count

Currently not in use.

CC

event

int

0-2147483647

count

When it is not possible to find the TAI information for the TargetID received via the Handover Required or the remote MME information, it is transmitted by being specified in the Handover Preparation Failure.

CC

event

int

0-2147483647

S1AP_no_radio_res ources_available_in _target_cell S1AP_unknown_mm e_ue_s1ap_id S1AP_unknown_enb _ue_s1ap_id S1AP_unknown_pair _ue_s1ap_id S1AP_handover_de sirable_for_radio_re ason S1AP_time_critical_

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 182 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name handover S1AP_resource_opti misation_handover S1AP_reduce_load_ in_serving_cell S1AP_user_inactivit y S1AP_radio_connec tion_with_ue_lost S1AP_load_balancin g_tau_required

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

When the RLB value of MME-INF is changed to other value than NONE, it is transmitted by being specified in the UE context release command for MME re-load balancing.

CC

event

int

0-2147483647

S1AP_cs_fallback_tr iggered S1AP_ue_not_availa ble_for_ps_service S1AP_radio_resourc es_not_available

count

A call is released due to CSFB that causes the inter-RAT redirection.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

A call is released due to resource allocation failure in eNB for the bearer where setup is requested by the MME.

CC

event

int

0-2147483647

S1AP_failure_in_rad io_interface_procedu

count

Currently not in use.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 183 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name re S1AP_invalid_qos_c ombination

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

- When gbrType of QCI received within E_RABLevelQoSParameters IE of the Initial Context Setup Request message is GBR but the gbrQosInformation received is the not present message - When gbrType of QCI received within E_RABLevelQoSParameters IE of the E_RAB Setup Request message is GBR but the gbrQosInformation received is the not present message - When gbrType of QCI received within E_RABLevelQoSParameters IE of the E_RAB Modify Request message is GBR but the gbrQosInformation received is the not present message

CC

event

int

0-2147483647

S1AP_interrat_redire ction

count

A call is released due to the interRAT redirection. It occurs when redirection is processed normally due to the inter-RAT redirection.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 184 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S1AP_interaction_wi th_other_procedure S1AP_unknown_E_ RAB_ID S1AP_multiple_E_R AB_ID_instances

Unit count

Description Currently not in use.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Currently not in use.

CC

event

int

0-2147483647

count

A call is released due to receiving the information with the same ERAB ID after the Initial Context Setup Request message is received.

CC

event

int

0-2147483647

S1AP_encryption_a nd_or_integrity_prot ection_algorithms_n ot_supported S1AP_s1_intra_syst em_handover_trigge red S1AP_s1_inter_syst em_handover_trigge red S1AP_x2_handover _triggered S1AP_redirection_to wards_1xRTT S1AP_not_supporte d_QCI_value

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

A call is released due to redirection to 1xRTT.

CC

event

int

0-2147483647

count

A call is released due to receiving the QCI value not supported by

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 185 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description eNB through the Initial Context Setup Request message.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

S1AP_invalid_CSG_ Id S1AP_transport_reso urce_unavailable S1AP_CauseTransp ort_unspecified S1AP_normal_relea se S1AP_authentication _failure

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

MME transmits the UE Context Release Command message including the cause value due to the UE authentication failure during the attach.

CC

event

int

0-2147483647

S1AP_detach S1AP_CauseNas_u nspecified S1AP_csg_subscript ion_expiry

count count

Currently not in use. Currently not in use.

Y Y

CC CC

event event

int int

0-2147483647 0-2147483647

count

If S1 is released because the UE whose location was registered in the CSG area has no or expired CSG subscription, the UE Context Release command is transmitted. The CSG-related causes will be supported later.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 186 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S1AP_transfer_synt ax_error S1AP_abstract_synt ax_error_reject S1AP_abstract_synt ax_error_ignore_and _notify S1AP_message_not _compatible_with_re ceiver_state S1AP_semantic_err or S1AP_abstract_synt ax_error_falsely_con structed_message S1AP_CauseProtoc ol_unspecified S1AP_control_proce ssing_overload S1AP_not_enough_ user_plane_processi ng_resources S1AP_hardware_fail ure S1AP_om_interventi

Unit count

Description Currently not in use.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 187 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name on S1AP_CauseMisc_u nspecified S1AP_unknown_PL MN X2AP_handover_de sirable_for_radio_re asons X2AP_time_critical_ handover X2AP_resource_opti misation_handover X2AP_reduce_load_ in_serving_cell X2AP_partial_hando ver X2AP_unknown_ne w_eNB_UE_X2AP_I D X2AP_unknown_old _eNB_UE_X2AP_ID X2AP_unknown_pair _of_UE_X2AP_ID X2AP_ho_target_not _allowed

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

If the DRB CAC procedure fails in the target during X2 handover, this

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 188 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description will be included in the X2_IN and X2_OUT preparation fail statistics.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

X2AP_tx2relocoveral l_expiry X2AP_trelocprep_ex piry

count

Currently not in use.

CC

event

int

0-2147483647

count

If the Handover Request Acknowledge message is not received from the target eNB during X2 handover, this will be included in the X2_OUT preparation fail statistics of the source eNB.

CC

event

int

0-2147483647

X2AP_cell_not_availa ble X2AP_no_radio_res ources_available_in _target_cell

count

Currently not in use.

CC

event

int

0-2147483647

count

If the cell information corresponding to the target ID transmitted via the handover request message is not found in the target eNB, this will be included in the X2_IN and X2_OUT preparation fail statistics.

CC

event

int

0-2147483647

X2AP_invalid_MME _GroupID X2AP_unknown_MM E_Code X2AP_encryption_a nd_or_integrity_prot

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 189 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ection_algorithms_n ot_supported X2AP_reportCharact eristicsEmpty X2AP_noReportPeri odicity X2AP_existingMeas urementID X2AP_unknown_eN B_Measurement_ID X2AP_measurement _temporarily_not_av ailable X2AP_CauseRadioN etwork_unspecified X2AP_load_balancin g X2AP_handover_opt imisation X2AP_value_out_of _allowed_range

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

A call is released when the QCI value of the E-RAB level QoS parameters is out of the range specified in the specification during bearer setup in the target eNB. This will be included in the X2_IN

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 190 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description and X2_OUT preparation fail statistics.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

X2AP_multiple_E_R AB_ID_instances

count

A call is released when setup is requested for the same ERAB ID during bearer setup in the target eNB. This will be included in the X2_IN and X2_OUT preparation fail statistics.

CC

event

int

0-2147483647

X2AP_switch_off_on going X2AP_transport_res ource_unavailable

count

Currently not in use.

CC

event

int

0-2147483647

count

A call is released when the internal resource setup fails in the target eNB during X2 handover; this will be included in the X2 IN Preparation Fail cause.

CC

event

int

0-2147483647

X2AP_CauseTransp ort_unspecified X2AP_transfer_synt ax_error X2AP_abstract_synt ax_error_reject X2AP_abstract_synt ax_error_ignore_and _notify X2AP_message_not

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 191 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name _compatible_with_re ceiver_state X2AP_semantic_err or X2AP_CauseProtoc ol_unspecified X2AP_abstract_synt ax_error_falsely_con structed_message X2AP_control_proce ssing_overload X2AP_hardware_fail ure X2AP_om_interventi on X2AP_not_enough_ user_plane_processi ng_resources X2AP_CauseMisc_u nspecified

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

Currently not in use.

CC

event

int

0-2147483647

count

The Handover Cancel message is transmitted to the target eNB due to reestablishment to the source eNB during X2 handover. This call release will be included the X2_IN Fail statistics.

CC

event

int

0-2147483647

ECC_TMOUT_rrcCo

count

A call is released when the RRC

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 192 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name nnectionSetupCompl ete

Unit

Description Connection Setup Complete message is not received after the RRC Connection Setup message is transmitted to the UE.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ECC_TMOUT_rrcCo nnectionReconfigCo mplete

count

A call is released when the RRC Connection Reconfiguration Complete message is not received after transmitting the RRC Connection Reconfiguration message.

CC

event

int

0-2147483647

ECC_TMOUT_rrcCon nectionReEstablishCo mplete

count

A call is released when the RRC Connection Reestablishment Complete message is not received from the UE after transmitting the RRC Connection Reestablishment message to the UE.

CC

event

int

0-2147483647

ECC_TMOUT_rrcSe curityModeComplete

count

A call is released when the Security Mode Complete message is not received after the Security Mode Command message is transmitted to the UE.

CC

event

int

0-2147483647

ECC_TMOUT_rrcUe CapabilityInformatio n

count

A call is released when the UE Capability Information message is not received after the UE Capability Enquiry message is transmitted to the UE.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 193 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ECC_TMOUT_rrcHa ndoverPreparation

Unit count

Description A call is released when the UL Handover Preparation Transfer message is not received after transmitting the Handover From EUTRA Preparation Request during the Inter RAT HRPD handover. Not applicable to the service provider who does not use the HRPD handover.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ECC_TMOUT_intra_ HandoverCmdCompl ete

count

A call is released when the target cell cannot receive the RRC Connection Reconfiguration Complete message during the intra-handover.

CC

event

int

0-2147483647

ECC_TMOUT_inter_ X2HandoverCmdCo mplete

count

A call is released when the target eNB cannot receive the RRC Connection Reconfiguration Complete message during the X2 handover.

CC

event

int

0-2147483647

ECC_TMOUT_inter_ S1HandoverCmdCo mplete

count

A call is released when the target eNB cannot receive the RRC Connection Reconfiguration Complete message during the S1 handover.

CC

event

int

0-2147483647

ECC_TMOUT_s1Init

count

A call is released when the Initial

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 194 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ialContextSetupReq uest

Unit

Description Context Setup Request message is not received after transmitting the Initial UE message to the MME.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ECC_TMOUT_s1Pat hSwitchAck

count

A call is released when the Path Switch Request Acknowledge message is not received after the target eNB transmits the Path Switch Request message during the X2 handover.

CC

event

int

0-2147483647

ECC_TMOUT_s1Ha ndoverPreparation

count

A call is released when DownlinkS1cdma2000tunneling message is not received after transmitting the UplinkS1cdma2000tunneling message to MME during the Inter RAT HRPD handover. Not applicable to the service provider who does not use the HRPD handover.

CC

event

int

0-2147483647

ECC_TMOUT_s1Rel ocOverall

count

A call is released when a RelocOverall Timeout occurs in the source eNB during the S1 handover.

CC

event

int

0-2147483647

ECC_TMOUT_s1M MEStatusTransfer

count

A call is released when the target eNB cannot receive the MME

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 195 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description Status Transfer message after the source eNB transmits the eNB Status Transfer message to the MME.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ECC_TMOUT_x2Rel ocOverall

count

A call is released when a RelocOverall Timeout occurs in the source eNB during the X2 handover.

CC

event

int

0-2147483647

ECC_TMOUT_x2SN StatusTransfer

count

A call is released when the target eNB cannot receive the X2 SN Status Transfer message transmitted from the source eNB.

CC

event

int

0-2147483647

ECC_TMOUT_intern alResourceSetup

count

A response message is not received after the SetupReq message is transmitted to allocate resources to the protocol blocks within the eNB.

CC

event

int

0-2147483647

ECC_TMOUT_intern alSecurityControl

count

A call is released when a response is not received from the PDCB block while transferring the security information to eNBs internal PDCB block during attach procedure.

CC

event

int

0-2147483647

ECC_TMOUT_intern alForwardingPathSet up

count

A call is released when no response is received for the request of uplink and downlink

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 196 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description path setup between the ECCB block and the eNBs internal block GTPB during handover.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ECC_TMOUT_intern alReestablishControl

cunt

A call is released when no response message is received from RLCB and PDCB blocks while configuring the eNBs ECCB block and internal RLCB & PDCB blocks for RLC and PDCP Reestablishment during X2/S1 handover.

CC

event

int

0-2147483647

ECC_TMOUT_intern alBufferFlush

count

A call is released when no response message is received from PDCB while interfacing between ECCB and PDCB for buffer flush during handover.

CC

event

int

0-2147483647

ECC_TMOUT_intern alDataTransferStart

count

A call is released when PDCP setup fails in the target eNB during handover.

CC

event

int

0-2147483647

ECC_USER_INACTI VITY

count

A call is released due to no traffic transmission during the given period of time (user inactivity time) for a specific UE when the MACB block detects the user inactivity, and notifies the fact to the ECCB block.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 197 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ECC_ARQ_MAX_R E_TRANSMISSION

Unit count

Description A call is released when the RLCB block made transmission to the UE as many times as the Max Retransmission, but ARQ ACK is not received from the UE, which is notified to the ECCB.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ECC_RADIO_LINK_ FAILURE

count

When the MACB determines the Sync disconnection with the UE, it notifies the ECCB of OutOfSync. If the ECCB is notified of the MACB of being InSync again (HARQACK/NACK received 20 times), or if it fails to receive the RRC Connection Reestablishment Request from the UE, the call is released after a timeout (default: 5 seconds).

CC

event

int

0-2147483647

ECC_UE_CONTEX T_NOT_FOUND

count

Although the UE requested the Reestablishment, cannot perform Reestablishment because could not find the UE Context information in eNB.

CC

event

int

0-2147483647

ECC_S1AP_SN_ST ATUS_NOT_RECEI VED

count

If the RRC Connection Reestablishment Request message is received while waiting for the SN Status Transfer message from the source eNB or

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 198 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description the MME Status Transfer message from the MME, the RRC Connection Reestablishment Reject message is transmitted to the UE.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ECC_REEST_FAIL_ INVALID_STATE

count

If the RRC Connection Reestablishment Request message is received during Attach, the eNB detects that reestablishment occurs while the DRB setup is not normal, and releases the call.

CC

event

int

0-2147483647

ECC_CDMA_HAND OVER_PREPARATI ON_FAILURE

count

A call is released when the UL Handover Preparation Transfer message is not received after transmitting the Handover From EUTRA Preparation Request during the Inter RAT HRPD handover.

CC

event

int

0-2147483647

ECC_RCV_S1_UEC TXTRELEASECMD_ ABNORMAL_STATE

count

A call is released when the UE Context Release Command message is received when the UE Associated setup is not made with the MME. If this cause occurs, it is necessary to check the cause value delivered to the MME.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 199 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ECC_RCV_RESET_ REQUEST_FROM_ ECMB ECC_RCV_S1_RES ET_FROM_MME

Unit count

Description A call is released due to receiving a reset request from ECMB due to refork of a specific block in eNB.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

The call in the handover process is released by receiving a reset message from the MME.

CC

event

int

0-2147483647

ECC_RCV_X2_RES ETREQUEST

count

A call is released due to the reception of the Reset Request message from other eNB.

CC

event

int

0-2147483647

ECC_S1_SCTP_OU T_OF_SERVICE

count

A call is released when the S1 Associations status is changed from In Service to Out of Service state.

CC

event

int

0-2147483647

ECC_RCV_CELL_R ELEASE_IND_FRO M_ECMB

count

A call is released due to the Cell Release Ind message received from the ECMB block because of DSP down or CPRI failure caused by DSP problem. (CPRI deleted)

CC

event

int

0-2147483647

ECC_DSP_AUDIT_ RLC_CALL_RELEA SE

count

A call is released when the call remains in the ECCB and MACB, but not in the RLCB, which causes resource mismatch.

CC

event

int

0-2147483647

ECC_DSP_AUDIT_ MAC_CALL_RELEA SE

count

A call is released when the call remains in the ECCB and RLC, but not in the MACB, which causes resource mismatch.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 200 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ECC_DSP_AUDIT_R LC_MAC_CALL_REL EASE

Unit count

Description A call is released when the call remains in the ECCB, but not in the RLC and MAC, which causes resource mismatch.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ECC_S_ALGORITH MS_COMBINATION _INVALID

count

The security algorithm value is received in the Initial Context Setup Request, S1 Handover Request, X2 Handover Request, S1 UE Context Modification message. A call is released when the ciphering algorithm does not have the null algorithm value if the integrity algorithm supports the null algorithm.

CC

event

int

0-2147483647

ECC_X2_SCTP_OU T_OF_SERVICE

count

A call is released when the X2 Associations status is changed from In Service to Out of Service state.

CC

event

int

0-2147483647

ECC_RELEASE_DU E_TO_ENB_GENER ATED_REASON ECC_INTER_FA_R EDIRECTION

count

A call is released due to the internal cause in eNB.

CC

event

int

0-2147483647

count

When processing the redirection to the inter FA (If it conflicts with the CRR output conditions based on the S1AP cause, the CRR in the

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 201 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description column D (Call Release Cause) is displayed.)

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

ECC_CSFB_CONFI G_FAILURE

count

A call is released when, even if CSFB was triggered by the InitialContextSetupRequest message, the CSFB redirection cannot be processed due to eNB setting error (Inter RAT FA information not specified).

CC

event

int

0-2147483647

RRM_FAIL

count

The DB initialization procedure managed by the ERRM fails.

CC

event

int

0-2147483647

RRM_CELL_BARRED

count

A call is released when RRC Connection Reject message is transmitted due to call rejection because the relevant cell is barred even when the RRC Connection Request message is received.

CC

event

int

0-2147483647

RRM_MAX_CALL_C OUNT_OVER

count

When calls are generated exceeding the number of calls that can be accommodated, they are rejected by CAC.

CC

event

int

0-2147483647

RRM_MAX_DRB_C OUNT_OVER

count

When calls are generated exceeding the number of DRB that can be accommodated by cell, they are rejected by CAC.

CC

event

int

0-2147483647

RRM_QOSCAC_FAIL

count

The call with the QoS that cannot

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 202 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description be allowed by the cell is generated; it is rejected by CAC.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RRM_PREEMPTIO N_FAIL

count

Preemption fails because the requested ERABs priority is under the priority of the existing UE.

CC

event

int

0-2147483647

RRM_CALLRSC_FA IL RRM_BHCAC_FAIL

count

Call ID is all assigned thus Call ID cannot be assigned any more.

CC

event

int

0-2147483647

count

A call is released when the BH link usage by a specific QoS (GBR Bearer) exceeds the threshold defined in the PLD.

CC

event

int

0-2147483647

RRM_SRSRSC_FAIL

count

When a new call supports both SRS and DRX, the SRS resources need to assigned in advance to assign the DRX resources but the DRX resources cannot be assigned because the SRS resource is not assigned.

CC

event

int

0-2147483647

RRM_CQIRSC_FAIL

count

CQI/PMI resources are all assigned thus cannot assign the resource any more.

CC

event

int

0-2147483647

RRM_SPSRSC_FAIL

count

SPS resources are all assigned thus the SPS resource cannot be assigned any more.

CC

event

int

0-2147483647

RRM_N1PUCCHRS C_FAIL

count

n1PucchAnRep resources are all assigned thus the resource cannot

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 203 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description be assigned any more.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RRM_SRRSC_FAIL

count

During SR resource allocation and release, the SR resource search is not allowed to exceed the Max value of the SR resource DB.

CC

event

int

0-2147483647

RRM_TPCRSC_FAIL

count

During TPC PUCCH RNTI resource allocation and release, the TPC PUCCH resource search is not allowed to exceed the Max value of TPC PUCCH resource DB.

CC

event

int

0-2147483647

RRM_ALL_MME_N OT_SERVICE

count

A call is rejected because there exists no MME currently in connection.

CC

event

int

0-2147483647

RRM_MME_OVERL OAD

count

When the MME is in Overload status, cannot accommodate the calls because overloadAction and establishmentCause does not match.

CC

event

int

0-2147483647

RRM_NOT_EXIST_ MME

count

The registered MME information that the UE informs in the RRC Connection Setup Complete message does not exist in the eNB database.

CC

event

int

0-2147483647

RRM_AVAILABLE_ MME_NOT_EXIST

count

The MME with the PLMN value informed by the UE does not exist

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 204 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description in the RRC Connection Setup Complete message.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RRM_UE_STMSI_D UPLICATE

count

The same UE transmits the RRC Connection Request with the same S-TMSI value.

CC

event

int

0-2147483647

GTP_SETIP_FAIL

count

A call is released when a response to GTP Setup Fail is transmitted after the SetupReq message is received from the ECCB. Tunnel information error managed by the GTPB block and tunnel setting failure due to DB management error are notified to the ECCB.

CC

event

int

0-2147483647

GTP_RELEASE_FAIL

count

An error response is generated when GTP Release fails.

CC

event

int

0-2147483647

GTP_MODIFY_FAIL

count

A call is released when a response to GTP Modify Fail is transmitted after the ModifyReq message is received from the ECCB. Tunnel information error managed by the GTPB block and tunnel setting failure due to DB management error are notified to the ECCB.

CC

event

int

0-2147483647

GTP_RESET_FAIL

count

A call is released if there is

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 205 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description response for Gtp setup fail after receiving the ModifyReq message from the ECMB.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

GTP_PATH_FAIL

count

If there is no Echo Response within 60 seconds after Echo Request is transmitted periodically to the peer node of the EPS bearer, the request is retransmitted five times at the interval of 5 seconds. If there is still no response, ECCB receives the response indicating a path to the peer node is abnormal. The GTPB block determines that a bearer path to the peer node is abnormal or GTP entity within the peer node is abnormal and notifies the ECCB block of the failure.

CC

event

int

0-2147483647

GTP_NOT_SUPPO RT_EH

count

Send a response when receiving the message with the extension header that cannot be supported by the system from dst peer during tunnel setup.

CC

event

int

0-2147483647

GTP_RCV_ERROR _IND_FROM_GW

count

A bearer is released when an error indication message is received from the peer node of GTPB, which is notified to the ECCB.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 206 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PDCP_INVALID_CAL LID

Unit count

Description An error response is generated when the callid of the downloaded message from the ECCB is the value of the MAX_USER_ENB or higher.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

PDCP_INVALID_RB ID

count

When Rbid of the message received from ECCB is MAX_RB or less for PDCP_DRB and MAX_SRB or less for PDCP_SRB, the message is normal. Otherwise, an error response is generated. There is no possibility that it will a CSL cause.

CC

event

int

0-2147483647

PDCP_INVALID_NU MOFRB

count

An error response is generated when the NumRb of the downloaded message from the ECCB is the value of the CI_MAX_RB or higher.

CC

event

int

0-2147483647

PDCP_INVALID_RL CMODE

count

An error response is generated when the RLC mode of the message downloaded from the ECCB is invalid.

CC

event

int

0-2147483647

PDCP_INVALID_SE TUPTYPE

count

An error response is generated when the setupType of the message downloaded from the ECCB is invalid.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 207 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PDCP_INVALID_CN TLTYPE

Unit count

Description An error response is generated when the CntlType of the message downloaded from the ECCB is invalid.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

PDCP_INVALID_PD CPSNTYPE

count

An error response is generated when the SNType of the message downloaded from the ECCB is UM, but not 7-bit or 12-bit.

CC

event

int

0-2147483647

PDCP_INVALID_LO CHTYPE

count

An error response is generated when the logical type of the message downloaded from the ECCB is other than either LOCH_DCCH (for the SRB) or LOCH_DTCH (for the DRB). There is no possibility that it will a CSL cause.

CC

event

int

0-2147483647

PDCP_ROHC_SET UP_FAIL

count

An error response is generated when the ROHC context setup procedure fails due to lack of memory while receiving ConfigReq from the ECCB.

CC

event

int

0-2147483647

PDCP_INACTIVATE _RBID

count

A call is released when the message on Inactive RB is received while receiving the msgCpdcpModifyReq from the ECCB

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 208 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PDCP_SRB_INTEG RITY_FAIL

Unit count

Description A call is released when SRBs integrity check failure notification is received from the PDCB.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RLC_INVALID_PAR AMETER

count

An error response is generated when the parameter of the message received from the ECCB is not the value within the defined range.

CC

event

int

0-2147483647

RLC_NO_MORE_R ESOURCE

count

An error response is generated when a new connection cannot be allowed due to insufficient resources to be allocated to the message received from the ECCB.

CC

event

int

0-2147483647

RLC_CELL_IS_IDLE

count

An error response is generated when cell ID status of the message received from the ECCB is IDLE, not ACTIVE.

CC

event

int

0-2147483647

RLC_CALL_IS_NOT _ACTIVE

count

An error response is generated when the call ID status of the message received from the ECCB is not ACTIVE.

CC

event

int

0-2147483647

RLC_ERROR_EMP TY_MSG

count

An error response is generated when the message received by the RLC is NULL.

CC

event

int

0-2147483647

RLC_ERROR_UNK NOWN_MSG_ID

count

An error response is generated when the type of the message

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 209 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description received by the RLC is unknown

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RLC_ERROR_INVA LID_DATA_LEN

count

An error response is generated when the size of the message received by the RLC is abnormal.

CC

event

int

0-2147483647

RLC_ERROR_NO_ RSP_FROM_DL

count

An error response is generated when the RLC downlink does not respond to the message received.

CC

event

int

0-2147483647

RLC_ERROR_NO_ RSP_FROM_UL

count

An error response is generated when the RLC uplink does not respond to the message received.

CC

event

int

0-2147483647

RLC_ERROR_NO_ RSP_FROM_DLUL

count

An error response is generated when the RLC downlink and uplink do not respond to the message received.

CC

event

int

0-2147483647

RLC_ERROR_RX_BE FORE_RLC_READY

count

An error response is generated when the RLC uplink receives a signaling message before it operates properly.

CC

event

int

0-2147483647

RLC_ERROR_INVA LID_RLC_TRANSA CTION_ID

count

An error response is generated when the transaction ID exceeds the specified range while the RLC processes the message received from the ECCB.

CC

event

int

0-2147483647

RLC_ERROR_INVA LID_CONTEXT

count

An error response is generated when a response is retransmitted from the RLC downlink for the

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 210 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description signaling message that the RLC has already processed.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RLC_ERROR_RLC_ CONTEXT_FULL

count

An error code is generated when the number of the signaling messages received exceeds the capacity that the RLC can process.

CC

event

int

0-2147483647

MAC_INVALID_MS GID MAC_INVALID_SET UPTYPE MAC_INVALID_CAL L_CELLID

count

An undefined Message Id is received.

CC

event

int

0-2147483647

count

An undefined SetupType is received. When the cell call ID value of the message received from the ECCB is outside the defined range.

CC

event

int

0-2147483647

count

CC

event

int

0-2147483647

MAC_INVALID_PAR AMETER MAC_INSUFFICIEN T_RESOURCE

count

When the parameter received is outside the defined range.

CC

event

int

0-2147483647

count

The RB cannot be allocated due to insufficient MACB internal resource required to manage the RB.

CC

event

int

0-2147483647

MAC_NOT_ASSIGN ED_RB

count

A reconfig/delete request is received for the RB that is not allocated.

CC

event

int

0-2147483647

MAC_NOT_ASSIGN ED_UE MAC_NOT_ASSIGN _SRB1

count

A config/delete request is received for the UE that is not allocated.

CC

event

int

0-2147483647

count

When the call setup message is received without SRB1 setup.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 211 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MAC_INVALID_RB_ CONFIG

Unit count

Description When the RB number within the Logical Channel Config exceeds the maximum value.

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

MAC_INVALID_CELL _ID

count

When the cell that corresponds to the received message is idle.

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 212 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

MRO_RLF
Mobility Robustness Optimization (MRO) statistics are intended to collect and classify handover issues due to Radio Link Failure (RL F) occurring during or after a handover, and use them in the MRO algorithm to optimize handover parameters (e.g. Cell Individual Off set) and improve the handover performance.

8.1

MRO RLF Classification


The causes of the handover related RLF recorded as MRO issue are: too-late handover, too-early handover, and handover to a wrong c ell. The causes of RLF not recorded as a MRO issue, are recorded as coverage hole. Index
Name cNum Neighbor cell 0~2 0~268435455 Range Cell Index Neighbor cell index Description

Type
Name CoverageHole Unit count Description Number of RLF/HO failures due to the coverage hole CoverageHoleN count Number of RLF/HO failures due to the coverage hole toward Cell N Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 213 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name TooEarlyHOFailu re

Unit count

Description The number of too-early handovers after transmitting the handover command

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

TooEarlyHORLF AfterHO

count

The number of too-early handovers after completing the handover process.

CC

event

int

0-2147483647

TooLateHORLF BeforeTriggering TooLateHORLFA fterTriggering WrongCellRLFAf terTriggering

count

The number of RLFs before triggering the handover.

CC

event

int

0-2147483647

count

The number of RLFs after the handover command is transmitted.

CC

event

int

0-2147483647

count

The number of handovers to a wrong cell before transmitting the handover command.

CC

event

int

0-2147483647

WrongCellRLFAf terHO

count

The number of handovers to a wrong cell after transmitting the handover command.

CC

event

int

0-2147483647

BlackCellRLFAft erHO PingpongHando ver

count

The number of handovers to a black cell RLF after HO (X2)

CC

event

int

0-2147483647

count

The number of ping-pong handovers detected by the ping-pong detection algorithm.

CC

event

int

0-2147483647

MroRlfCnt

count

MRO RLF Classification collection count

CC

event

int

0~214748364 7

MroRlfCid

Neighbor Cell ID

NeighborCell ID of which collection is requested

OW

event

int

0~214748364 7

SAMSUNG Electronics Co., Ltd.

page 214 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

GTP
The GPRS Tunneling Protocol Block (GTPB) handles the GPRS Tunneling Protocol for data access from the S1-U or X2-U, manages the GTP tunnels for the E-RAB, and transmits/receives user data. GTP statistics are on the GTP layer packets that are received from t he S1-U (S-GW) over the downlink, which allow the operator to detect the backhaul condition.

9.1

GTP Sequence Number by QCI


This section provides statistics data for the count of lost downlink packets and the count of Out of Sequence downlink packets in the GTP layer. Index
Name QCI Range 0~255 Description QoS Class Identifier

Type
Name GtpSnPeakLoss Qci Unit count Description Count of downlink GTP packets which have been regarded to be lost until the statistics collection time. GtpSnOosQci count Count of Out of Sequence downlink packets (i.e. the accumulated count of packets which order of the GTP Sequence Number is reversed) for each QCI. Y CC 2 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 2 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 215 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

9.2

GTP Sequence Number by eNB


This section provides statistics data for the count of lost downlink packets and the count of Out of Sequence downlink packets in the GTP layer for the eNB. Type
Name GtpSnPeakLoss Enb Unit count Description Count of downlink GTP packets which have been regarded to be lost until the statistics collection time. GtpSnOosEnb count Count of Out of Sequence downlink packets (i.e. the accumulated count of packets which order of the GTP Sequence Number is reversed) for each QCI. GtpDlCntEnb count Number of the downlink GTP packets received until the time of counting the statistic. GtpSnLossEnb Rate % Ratio of the downlink GTP packets lost against the total packets until the time of collecting the statistics * lost packet = GtpSnPeakLossEnb Y OW Period float 0-100 GtpSnPeakLossE nb/(GtpDlCntEnb+ GtpSnPeakLossE nb-GtpSnOosEnb) *100 sum (GtpSnPeakLossEnb)/ (sum (GtpDlCntEnb)+ sum (GtpSnPeakLossEnb) -sum Y CC 2 s. int 0-2147483647 Y CC 2 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 2 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 216 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description * total packet = GtpDlCntEnb + (GtpDlCntEnb GtpSnOosEnb)

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula (GtpSnOosEnb))*100

GtpSnOosEnbR ate

Total GTP Packet OOS rate per eNB

OW

Period

float

0-100

SAMSUNG Electronics Co., Ltd.

page 217 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

9.3

GTP Forward Traffic


The GTP Forward Traffic statistic is defined as the downlink/uplink count/byte/throughput of forwarding traffic during calls, S1/X2 han dovers and inter-RAT S1/X2 handovers. In statistics items, DL is based on the received packets and UL is based on the transmitted pa ckets. Type
Name CntGtpDlEnbS1 Nor CntGtpUlEnbS1 Nor CntGtpDlEnbS1 FW count count Unit count Description Number of S1 downlink GTP packets during the basis call. Number of S1 uplink GTP packets during the basis call. Number of forwarded packets received in the S1 downlink during the S1 handover. CntGtpUlEnbS1 FW CntGtpDlEnbX2 FW count count Number of packets forwarded to the S1 uplink during the S1 handover. Number of forwarded packets received in the X2 downlink during the X2 handover. CntGtpUlEnbX2 FW CntGtpDlEnbIR atUtraS1FW count count Number of packets forwarded to the X2 uplink during the X2 handover. Number of forwarded packets received in the S1 downlink during the inter-RAT (UTRAN) handover. Y CC 20 s. int 0-2147483647 Y CC 20 s. int 0-2147483647 Y CC 20 s. int 0-2147483647 Y CC 20 s. int 0-2147483647 Y CC 20 s. int 0-2147483647 Y CC 20 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 20 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 218 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name CntGtpUlEnbIR atUtraS1FW

Unit count

Description Number of packets forwarded to the S1 uplink during the inter-RAT (UTRAN) handover.

Visible Y

Counter Type CC

Trigger Type 20 s.

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

CntGtpDlEnbIR atUtraX2FW

count

Number of forwarded packets received in the X2 downlink during the inter-RAT (UTRAN) handover.

CC

20 s.

int

0-2147483647

CntGtpUlEnbIR atUtraX2FW

count

Number of packets forwarded to the X2 uplink during the inter-RAT (UTRAN) handover.

CC

20 s.

int

0-2147483647

CntGtpDlEnbIR atGeranS1FW

count

Number of forwarded packets received in the S1 downlink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

CntGtpUlEnbIR atGeranS1FW

count

Number of packets forwarded to the S1 uplink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

CntGtpDlEnbIR atGeranX2FW

count

Number of forwarded packets received in the X2 downlink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

CntGtpUlEnbIR atGeranX2FW

count

Number of packets forwarded to the X2 uplink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

CntGtpDlEnbIR atCdma2000Hrp dS1FW

count

Number of forwarded packets received in the S1 downlink during the inter-RAT (CDMA2000 HRPD) handover.

CC

20 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 219 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name CntGtpUlEnbIR atCdma2000Hrp dS1FW CntGtpDlEnbIR atCdma2000Hrp dX2FW

Unit count

Description Number of packets forwarded to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.

Visible Y

Counter Type CC

Trigger Type 20 s.

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Number of forwarded packets received in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.

CC

20 s.

int

0-2147483647

CntGtpUlEnbIR atCdma2000Hrp dX2FW ByteGtpDlEnbS 1Nor ByteGtpUlEnbS 1Nor ByteGtpDlEnbS 1FW

count

Number of packets forwarded to the X2 uplink during the inter-RAT (CDMA2000 HRPD) handover.

CC

20 s.

int

0-2147483647

Kbytes

Bytes of S1 downlink GTP packets during the basis call.

CC

20 s.

int

0-2147483647

Kbytes

Bytes of S1 uplink GTP packets during the basis call.

CC

20 s.

int

0-2147483647

Kbytes

Bytes of forwarded packets received in the S1 downlink during the S1 handover.

CC

20 s.

int

0-2147483647

ByteGtpUlEnbS 1FW ByteGtpDlEnbX 2FW

Kbytes

Bytes of packets forwarded to the S1 uplink during the S1 handover.

CC

20 s.

int

0-2147483647

Kbytes

Bytes of forwarded packets received in the X2 downlink during the X2 handover.

CC

20 s.

int

0-2147483647

ByteGtpUlEnbX 2FW

Kbytes

Bytes of packets forwarded to the X2 uplink during the X2 handover.

CC

20 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 220 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ByteGtpDlEnbIR atUtraS1FW

Unit Kbytes

Description Bytes of forwarded packets received in the S1 downlink during the inter-RAT (UTRAN) handover.

Visible Y

Counter Type CC

Trigger Type 20 s.

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ByteGtpUlEnbIR atUtraS1FW

Kbytes

Bytes of packets forwarded to the S1 uplink during the inter-RAT (UTRAN) handover.

CC

20 s.

int

0-2147483647

ByteGtpDlEnbIR atUtraX2FW

Kbytes

Bytes of forwarded packets received in the X2 downlink during the inter-RAT (UTRAN) handover.

CC

20 s.

int

0-2147483647

ByteGtpUlEnbIR atUtraX2FW

Kbytes

Bytes of packets forwarded to the X2 uplink during the inter-RAT (UTRAN) handover.

CC

20 s.

int

0-2147483647

ByteGtpDlEnbIR atGeranS1FW

Kbytes

Bytes of forwarded packets received in the S1 downlink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

ByteGtpUlEnbIR atGeranS1FW

Kbytes

Bytes of packets forwarded to the S1 uplink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

ByteGtpDlEnbIR atGeranX2FW

Kbytes

Bytes of forwarded packets received in the X2 downlink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

ByteGtpUlEnbIR atGeranX2FW

Kbytes

Bytes of packets forwarded to the X2 uplink during the inter-RAT (GERAN) handover.

CC

20 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 221 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ByteGtpDlEnbIR atCdma2000Hrp dS1FW

Unit Kbytes

Description Bytes of forwarded packets received in the S1 downlink during the inter-RAT (CDMA2000 HRPD) handover.

Visible Y

Counter Type CC

Trigger Type 20 s.

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ByteGtpUlEnbIR atCdma2000Hrp dS1FW ByteGtpDlEnbIR atCdma2000Hrp dX2FW

Kbytes

Bytes of packets forwarded to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.

CC

20 s.

int

0-2147483647

Kbytes

Bytes of forwarded packets received in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.

CC

20 s.

int

0-2147483647

ByteGtpUlEnbIR atCdma2000Hrp dX2FW ThruGtpDlEnbS 1Nor

Kbytes

Bytes of packets forwarded to the X2 uplink during the inter-RAT (CDMA2000 HRPD) handover.

CC

20 s.

int

0-2147483647

Kbps

Throughput of S1 downlink GTP packets during the basis call.

SI

20 s.

float

0-3.4*10^38

ThruGtpDlE nbS1NorTot /ThruGtpDl EnbS1NorC nt

sum (ThruGtpDlEnbS1 NorTot)/sum (ThruGtpDlEnbS1 NorCnt) -

ThruGtpDlEnbS 1NorTot ThruGtpDlEnbS 1NorCnt

Kbps

The sum of collected ThruGtpDlEnbS1Nor

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpDlEnbS1Nor count

SI

20 s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 222 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpUlEnbS 1Nor

Unit Kbps

Description Throughput of S1 uplink GTP packets during the basis call.

Visible Y

Counter Type SI

Trigger Type 20 s.

Data Type float

Min/Max 0-3.4*10^38

Granularity Formula ThruGtpUlE nbS1NorTot )/ThruGtpUl EnbS1NorC nt

Hourly, Daily, Monthly Formula sum (ThruGtpUlEnbS1 NorTot)/sum (ThruGtpUlEnbS1 NorCnt) -

ThruGtpUlEnbS 1NorTot ThruGtpUlEnbS 1NorCnt ThruGtpDlEnbS 1FW

Kbps

The sum of collected ThruGtpUlEnbS1Nor

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbS1Nor count

SI

20 s

int

0~2147483647

Kbps

Throughput of forwarded packets received in the S1 downlink during the S1 handover.

SI

20 s.

float

0-3.4*10^38

ThruGtpDlE nbS1FWTot/ ThruGtpDlE nbS1FWCnt

sum (ThruGtpDlEnbS1 FWTot)/sum (ThruGtpDlEnbS1 FWCnt)

ThruGtpDlEnbS 1FWTot ThruGtpDlEnbS 1FWCnt ThruGtpUlEnbS 1FW

Kbps

The sum of collected ThruGtpDlEnbS1FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpDlEnbS1FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of packets forwarded to the S1 uplink during the S1 handover.

SI

20 s.

float

ThruGtpUlE nbS1FWTot/ ThruGtpUlE nbS1FWCnt

sum (ThruGtpUlEnbS1 FWTot)/sum (ThruGtpUlEnbS1 FWCnt)

ThruGtpUlEnbS 1FWTot

Kbps

The sum of collected ThruGtpUlEnbS1FW

SI

20 s

float

0~3.4*10^38

SAMSUNG Electronics Co., Ltd.

page 223 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpUlEnbS 1FWCnt ThruGtpDlEnbX 2FW

Unit count

Description Collected ThruGtpUlEnbS1FW count

Visible -

Counter Type SI

Trigger Type 20 s

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Kbps

Throughput of forwarded packets received in the X2 downlink during the X2 handover.

SI

20 s.

float

ThruGtpDlE nbX2FWTot/ ThruGtpDlE nbX2FWCnt

sum (ThruGtpDlEnbX2 FWTot)/sum (ThruGtpDlEnbX2 FWCnt)

ThruGtpDlEnbX 2FWTot ThruGtpDlEnbX 2FWCnt ThruGtpUlEnbX 2FW

Kbps

The sum of collected ThruGtpDlEnbX2FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpDlEnbX2FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of packets forwarded to the X2 uplink during the X2 handover.

SI

20 s.

float

ThruGtpUlE nbX2FWTot/ ThruGtpUlE nbX2FWCnt

sum (ThruGtpUlEnbX2 FWTot)/sum (ThruGtpUlEnbX2 FWCnt)

ThruGtpUlEnbX 2FWTot ThruGtpUlEnbX 2FWCnt ThruGtpDlEnbIR atUtraS1FW

Kbps

The sum of collected ThruGtpUlEnbX2FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbX2FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of forwarded packets received in the S1 downlink during the inter-RAT (UTRAN) handover.

SI

20 s.

float

ThruGtpDlE nbIRatUtraS 1FWTot/Thr uGtpDlEnbI RatUtraS1F WCnt

sum (ThruGtpDlEnbIRa tUtraS1FWTot)/ sum (ThruGtpDlEnbIRa tUtraS1FWCnt)

SAMSUNG Electronics Co., Ltd.

page 224 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpDlEnbIR atUtraS1FWTot ThruGtpDlEnbIR atUtraS1FWCnt ThruGtpUlEnbIR atUtraS1FW

Unit Kbps

Description The sum of collected ThruGtpDlEnbIRatUtraS1FW

Visible -

Counter Type SI

Trigger Type 20 s

Data Type float

Min/Max 0~3.4*10^38

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Collected ThruGtpDlEnbIRatUtraS1FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of packets forwarded to the S1 uplink during the inter-RAT (UTRAN) handover.

SI

20 s.

float

ThruGtpUlE nbIRatUtraS 1FWTot/Thr uGtpUlEnbI RatUtraS1F WCnt

sum (ThruGtpUlEnbIRa tUtraS1FWTot)/ sum (ThruGtpUlEnbIRa tUtraS1FWCnt) -

ThruGtpUlEnbIR atUtraS1FWTot ThruGtpUlEnbIR atUtraS1FWCnt ThruGtpDlEnbIR atUtraX2FW

Kbps

The sum of collected ThruGtpUlEnbIRatUtraS1FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbIRatUtraS1FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of forwarded packets received in the X2 downlink during the inter-RAT (UTRAN) handover.

SI

20 s.

float

ThruGtpDlE nbIRatUtraX 2FWTot/Thr uGtpDlEnbI RatUtraX2F WCnt

sum (ThruGtpDlEnbIRa tUtraX2FWTot)/ sum (ThruGtpDlEnbIRa tUtraX2FWCnt) -

ThruGtpDlEnbIR atUtraX2FWTot ThruGtpDlEnbIR atUtraX2FWCnt

Kbps

The sum of collected ThruGtpDlEnbIRatUtraX2FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpDlEnbIRatUtraX2FW count

SI

20 s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 225 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpUlEnbIR atUtraX2FW

Unit Kbps

Description Throughput of packets forwarded to the X2 uplink during the inter-RAT (UTRAN) handover.

Visible Y

Counter Type SI

Trigger Type 20 s.

Data Type float -

Min/Max

Granularity Formula ThruGtpUlE nbIRatUtraX 2FWTot/Thr uGtpUlEnbI RatUtraX2F WCnt

Hourly, Daily, Monthly Formula sum (ThruGtpUlEnbIRa tUtraX2FWTot)/ sum (ThruGtpUlEnbIRa tUtraX2FWCnt) -

ThruGtpUlEnbIR atUtraX2FWTot ThruGtpUlEnbIR atUtraX2FWCnt ThruGtpDlEnbIR atGeranS1FW

Kbps

The sum of collected ThruGtpUlEnbIRatUtraX2FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbIRatUtraX2FW count

SI

20 s

int

0~2147483647

Kbps

Bytes of forwarded packets received in the S1 downlink during the inter-RAT (GERAN) handover.

SI

20 s.

float

ThruGtpDlE nbIRatGera nS1FWTot/ ThruGtpDlE nbIRatGera nS1FWCnt

sum (ThruGtpDlEnbIRa tGeranS1FWTot)/ sum (ThruGtpDlEnbIRa tGeranS1FWCnt) -

ThruGtpDlEnbIR atGeranS1FWT ot ThruGtpDlEnbIR atGeranS1FWC nt

Kbps

The sum of collected ThruGtpDlEnbIRatGeranS1FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpDlEnbIRatGeranS1FW count

SI

20 s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 226 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpUlEnbIR atGeranS1FW

Unit Kbps

Description Throughput of packets forwarded to the S1 uplink during the inter-RAT (GERAN) handover.

Visible Y

Counter Type SI

Trigger Type 20 s.

Data Type float

Min/Max

Granularity Formula ThruGtpUlE nbIRatGera nS1FWTot/ ThruGtpUlE nbIRatGera nS1FWCnt

Hourly, Daily, Monthly Formula sum (ThruGtpUlEnbIRa tGeranS1FWTot)/ sum (ThruGtpUlEnbIRa tGeranS1FWCnt) -

ThruGtpUlEnbIR atGeranS1FWT ot ThruGtpUlEnbIR atGeranS1FWC nt ThruGtpDlEnbIR atGeranX2FW

Kbps

The sum of collected ThruGtpUlEnbIRatGeranS1FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbIRatGeranS1FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of forwarded packets received in the X2 downlink during the inter-RAT (GERAN) handover.

SI

20 s.

float

ThruGtpDlE nbIRatGera nX2FWTot/ ThruGtpDlE nbIRatGera nX2FWCnt

sum (ThruGtpDlEnbIRa tGeranX2FWTot)/ sum (ThruGtpDlEnbIRa tGeranX2FWCnt) -

ThruGtpDlEnbIR atGeranX2FWT ot ThruGtpDlEnbIR atGeranX2FWC nt

Kbps

The sum of collected ThruGtpDlEnbIRatGeranX2FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpDlEnbIRatGeranX2FW count

SI

20 s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 227 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpUlEnbIR atGeranX2FW

Unit Kbps

Description Throughput of packets forwarded to the X2 uplink during the inter-RAT (GERAN) handover.

Visible Y

Counter Type SI

Trigger Type 20 s.

Data Type float

Min/Max 0~3.4*10^38

Granularity Formula ThruGtpUlE nbIRatGera nX2FWTot/ ThruGtpUlE nbIRatGera nX2FWCnt

Hourly, Daily, Monthly Formula sum (ThruGtpUlEnbIRa tGeranX2FWTot)/ sum (ThruGtpUlEnbIRa tGeranX2FWCnt) -

ThruGtpUlEnbIR atGeranX2FWT ot ThruGtpUlEnbIR atGeranX2FWC nt ThruGtpDlEnbIR atCdma2000Hrp dS1FW

Kbps

The sum of collected ThruGtpUlEnbIRatGeranX2FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbIRatGeranX2FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of forwarded packets received in the S1 downlink during the inter-RAT (CDMA2000 HRPD) handover.

SI

20 s.

float

ThruGtpDlE nbIRatCdm a2000Hrpd S1FWTot/T hruGtpDlEn bIRatCdma 2000HrpdS 1FWCnt

sum (ThruGtpDlEnbIRa tCdma2000HrpdS 1FWTot)/sum (ThruGtpDlEnbIRa tCdma2000HrpdS 1FWCnt)

ThruGtpDlEnbIR atCdma2000Hrp dS1FWTot ThruGtpDlEnbIR atCdma2000Hrp dS1FWCnt

Kbps

The sum of collected ThruGtpDlEnbIRatCdma2000Hrpd S1FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpDlEnbIRatCdma2000Hrpd S1FW count

SI

20 s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 228 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpUlEnbIR atCdma2000Hrp dS1FW

Unit Kbps

Description Throughput of packets forwarded to the S1 uplink during the inter-RAT (CDMA2000 HRPD) handover.

Visible Y

Counter Type SI

Trigger Type 20 s.

Data Type float -

Min/Max

Granularity Formula ThruGtpUlE nbIRatCdm a2000Hrpd S1FWTot/T hruGtpUlEn bIRatCdma 2000HrpdS 1FWCnt

Hourly, Daily, Monthly Formula sum (ThruGtpUlEnbIRa tCdma2000HrpdS 1FWTot)/sum (ThruGtpUlEnbIRa tCdma2000HrpdS 1FWCnt)

ThruGtpUlEnbIR atCdma2000Hrp dS1FWTot ThruGtpUlEnbIR atCdma2000Hrp dS1FWCnt ThruGtpDlEnbIR atCdma2000Hrp dX2FW

Kbps

The sum of collected ThruGtpUlEnbIRatCdma2000Hrpd S1FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbIRatCdma2000Hrpd S1FW count

SI

20 s

int

0~2147483647

Kbps

Throughput of forwarded packets received in the X2 downlink during the inter-RAT (CDMA2000 HRPD) handover.

SI

20 s.

float

ThruGtpDlE nbIRatCdm a2000Hrpd X2FWTot/T hruGtpDlEn bIRatCdma 2000HrpdX 2FWCnt

sum (ThruGtpDlEnbIRa tCdma2000HrpdX 2FWTot)/sum (ThruGtpDlEnbIRa tCdma2000HrpdX 2FWCnt)

ThruGtpDlEnbIR atCdma2000Hrp dX2FWTot

Kbps

The sum of collected ThruGtpDlEnbIRatCdma2000Hrpd X2FW

SI

20 s

float

0~3.4*10^38

SAMSUNG Electronics Co., Ltd.

page 229 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThruGtpDlEnbIR atCdma2000Hrp dX2FWCnt ThruGtpUlEnbIR atCdma2000Hrp dX2FW

Unit count Collected

Description

Visible

Counter Type SI

Trigger Type 20 s

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

ThruGtpDlEnbIRatCdma2000Hrpd X2FW count Kbps Throughput of packets forwarded to the X2 uplink during the inter-RAT (CDMA2000 HRPD) handover. Y SI 20 s. float ThruGtpUlE nbIRatCdm a2000Hrpd X2FWTot/T hruGtpUlEn bIRatCdma 2000HrpdX 2FWCnt sum (ThruGtpUlEnbIRa tCdma2000HrpdX 2FWTot)/sum (ThruGtpUlEnbIRa tCdma2000HrpdX 2FWCnt)

ThruGtpUlEnbIR atCdma2000Hrp dX2FWTot ThruGtpUlEnbIR atCdma2000Hrp dX2FWCnt

Kbps

The sum of collected ThruGtpUlEnbIRatCdma2000Hrpd X2FW

SI

20 s

float

0~3.4*10^38

count

Collected ThruGtpUlEnbIRatCdma2000Hrpd X2FW count

SI

20 s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 230 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

10 SRB
Signalling Radio Bearer (SRB, data Plane of PDCP) statistics provide the Control Plane PDCP SDU bit rates per cell over the downlin k and uplink respectively.

10.1 Cell PDCP SDU bit-rate


The eNB groups the Control Plane PDCP SDU bit rates per cell by the downlink/uplink in accordance with the 3GPP standard (TS32. 425 Performance Measurements) and calculates the average value at every measurement interval. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name PdcpSduBitrat eDl Unit Kbps Description Average cell bit-rate of the control plane PDCP SDUs over the downlink. Visible Y Counter Type SI Trigger Type 2 s. Data Type float Min/Max 0-3.4*10^38 Granularity Formula PdcpSduBitrateDlTot/ PdcpSduBitrateDlCnt Hourly, Daily, Monthly Formula sum (PdcpSduBitrateDlTot)/ sum (PdcpSduBitrateDlCnt) PdcpSduBitrat eDlTot PdcpSduBitrat eDlCnt count Kbps The sum of collected PdcpSduBitrateDl Collected PdcpSduBitrateDl count SI 2s int 0~21474836 47 SI 2s float 0~3.4*10^38 -

SAMSUNG Electronics Co., Ltd.

page 231 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdcpSduBitrat eUl

Unit Kbps

Description Average cell bit-rate of the control plane PDCP SDUs over the uplink.

Visible Y

Counter Type SI

Trigger Type 2 s.

Data Type float

Min/Max 0-3.4*10^38

Granularity Formula PdcpSduBitrateUlTot/ PdcpSduBitrateUlCnt

Hourly, Daily, Monthly Formula sum (PdcpSduBitrateUlTot)/ sum (PdcpSduBitrateUlCnt)

PdcpSduBitrat eUlTot PdcpSduBitrat eUlCnt

Kbps

The sum of collected PdcpSduBitrateUl

SI

2s

float

0~3.4*10^38

count

Collected PdcpSduBitrateUl count

SI

2s

int

0~21474836 47

SAMSUNG Electronics Co., Ltd.

page 232 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

11 DRB
Data Radio Bearer (DRB, User Plane of RLC/MAC) statistics provide QCI information of the DRB, such as the number of active UEs, packet delay, packet drop rate, packet loss rate and IP latency.

11.1 Active UEs


This section provides statistics data for the average number of UEs where the buffer data of the DRB is waiting. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name UEActiveDl Unit count Description The number of UEs satisfying one or more of the following conditions in a continuous 20 ms interval (sampling occasion) is summed every 80 ms for each QCI. - If there is a DRB which received a buffer occupancy request from the RLC - If there is a DRB which received an HARQ retransmission request When a collection interval ends, the average is calculated by Visible Y Counter Type SI Trigger Type 5.12 s. Data Type float Min/Max 0-3.4*10^38 Granularity Formula UEActiveDlTot/ UEActiveDlCnt Hourly, Daily, Monthly Formula sum (UEActiveDlTot)/ sum (UEActiveDlCnt)

SAMSUNG Electronics Co., Ltd.

page 233 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description dividing the summed number of UEs by the number of sampling occasions that occurred.

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

UEActiveDl Tot UEActiveDl Cnt UEActiveUl

count

Sum of UEActiveDl collected

SI

5.12 s.

float

0-3.4*10^38

count

Collected UEActiveDl count

SI

5.12 s

int

0~2147483 647

count

The number of UEs satisfying one or more of the following conditions in a continuous 20 ms interval is summed every 80 ms for each QCI. - If there is a DRB where the uplink data requested to be allocated using the Buffer Status Report message is waiting - If there is a DRB which received an HARQ retransmission request When a collection interval ends, the average is calculated by dividing the summed number of UEs by the number of sampling occasions that occurred.

SI

5.12 s.

float

0-3.4*10^38

UEActiveUlTot/ UEActiveUlCnt

sum (UEActiveUlTot)/ sum (UEActiveUlCnt)

UEActiveUl Tot UEActiveUl Cnt

count

Sum of UEActiveUl collected

SI

5.12 s.

float

0-3.4*10^38

count

Collected UEActiveUl count

SI

5.12 s

int

0~2147483 647

SAMSUNG Electronics Co., Ltd.

page 234 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

11.2 Packet Delay


This section provides statistics data for the DL PDCP SDU delay defined in the standard 3GPP TS 36.314 for each QCI. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name PdcpSduDelay Unit ms Description Average DL PDCP SDU delay DL PDCP SDU delay on the downlink that occurred for 1 minute. PdcpSduDelay Tot PdcpSduDelay Cnt count ms Sum of PdcpSduDelay collected Collected PdcpSduDelay count SI 10 s int 0~2147483647 Y SI 10 s. float 0-3.4*10^38 Visible Y Counter Type SI Trigger Type 10 s. Data Type float Min/Max 0-60*Period*1000 Granularity Formula PdcpSduDelayTot/ PdcpSduDelayCnt Hourly, Daily, Monthly Formula sum (PdcpSduDelayTot)/ sum (PdcpSduDelayCnt) -

SAMSUNG Electronics Co., Ltd.

page 235 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

11.3 Packet Drop Rate


Statistics provides per-eNB drop rate for downlink packet drops of the user plane traffic per QCI in accordance with the 3GPP standar d (TS32.425 Performance Measurements. Packet drops can occur due to traffic congestion and are calculated (in ppm) by multiplying it by 1E6 according to the standard (TS 36.314 Layer 2-Measurements). Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name PdcpSduDropRateDl Unit ppm Description DL PDCP SDU packet drop rate on the downlink that occurred for one minute Visible Y Counter Type SI Trigger Type 1 min. Data Type float Min/Max 03.4*10^38 Granularity Formula PdcpSduDr opRateDlTot /PdcpSduDr opRateDlCn t PdcpSduDropRateDl Tot PdcpSduDropRateDl Cnt count ppm The sum of collected PdcpSduDropRateDl Collected PdcpSduDropRateDl count SI 1 min int SI 1 min float 0~3.4*10^ 38 0~214748 3647 Hourly, Daily, Monthly Formula sum (PdcpSduDropRat eDlTot)/sum (PdcpSduDropRat eDlCnt) -

SAMSUNG Electronics Co., Ltd.

page 236 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdcpPduDropRateDl

Unit ppm

Description Average DL PDCP SDU drop rate DL PDCP SDU drop rate on the downlink that occurred for 1 minute.

Visible -

Counter Type SI

Trigger Type 10 s.

Data Type float

Min/Max 03.4*10^38

Granularity Formula PdcpPduDr opRateDlTot /PdcpPduDr opRateDlCn t

Hourly, Daily, Monthly Formula sum (PdcpPduDropRat eDlTot)/ sum (PdcpPduDropRat eDlCnt)

PdcpPduDropRateDl Tot PdcpPduDropRateDl Cnt

ppm

The sum of collected PdcpPduDropRateDl

SI

10 s

float

0~3.4*10^ 38

count

Collected PdcpPduDropRateDl count

SI

10 s

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 237 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

11.4 Packet Loss Rate (ppm)


Statistics provides per-eNB loss rate for PDCP SDUs of the user plane traffic that have not been received successfully over the uplink per QCI in accordance with the 3GPP standard (TS32.425 Performance Measurements). The rate is calculated (in ppm) by multiplying 1E6 according to the standard (TS 36.314 Layer 2-Measurements). Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name PdcpSduLossR ateUl Unit ppm Description UL PDCP SDU packet loss rate on the uplink that occurred for 1 minute Visible Y Counter Type SI Trigger Type 1 min. Data Type float Min/Max 0-3.4*10^38 Granularity Formula PdcpSduLo ssRateUlTot /PdcpSduLo ssRateUlCn t PdcpSduLossR ateUlTot PdcpSduLossR ateUlCnt count ppm The sum of collected PdcpSduLossRateUl Collected PdcpSduLossRateUl count SI 1 min int 0~21474836 47 SI 1 min float 0~3.4*10^38 Hourly, Daily, Monthly Formula sum (PdcpSduLossRateUlTot)/ sum (PdcpSduLossRateUlCnt)

SAMSUNG Electronics Co., Ltd.

page 238 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdcpSduAirIntf

Unit ppm

Description Average DL PDCP SDU loss rate DL PDCP SDU packet loss rate on the downlink that occurred for 10 seconds.

Visible Y

Counter Type SI

Trigger Type 10 s.

Data Type float

Min/Max 0-3.4*10^38

Granularity Formula PdcpSduAir IntfTot/Pdcp SduAirIntfC nt

Hourly, Daily, Monthly Formula sum (PdcpSduAirIntfTot)/sum (PdcpSduAirIntfCnt)

PdcpSduAirIntf Tot PdcpSduAirIntf Cnt

ppm

The sum of collected PdcpSduAirIntf

SI

10 s

float

0~3.4*10^38

count

Collected PdcpSduAirIntf count

SI

10 s

int

0~21474836 47

SAMSUNG Electronics Co., Ltd.

page 239 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

11.5 IP Latency measurements


This section provides statistics data for the DL IP latency defined in the standard 3GPP TS 32.450 for each QCI. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name IpLateDl Unit ms Description IP latency in the downlink, SAE bearer level IP latency for 10 seconds in the downlink. IpLateDlTot IpLateDlCnt ms count The sum of collected IpLateDl Collected IpLateDl count SI SI 10 s 10 s float int 0~3.4*10^38 0~2147483647 Visible Y Counter Type SI Trigger Type 10 s. Data Type float Min/Max 0-60*Period*1000 Granularity Formula IpLateDlTot/ IpLateDlCnt Hourly, Daily, Monthly Formula sum (IpLateDlTot)/ sum (IpLateDlCnt)

SAMSUNG Electronics Co., Ltd.

page 240 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

12 RRU
The Radio Resource Utilization (RRU) statistics include DL/UL PRB Usage, DL/UL Total PRB Usage, and Cell Unavailable Time stati stics. These statistics items are described in the following table.

12.1 DL/UL PRB Usage


This section provides rate of PRB allocated to the DTCH among the total PRB on the DL/UL. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name PrbDl Unit % Description The PRB usage used as the downlink DTCH traffic PrbDlTot PrbDlCnt PrbUl % count % The sum of collected PrbDl Collected PrbDl count The PRB usage used as the uplink DTCH traffic PrbUlTot % The sum of collected PrbUl SI 5.12 s float 0~3.4*10^38 SI SI SI 5.12 s 5.12 s 5.12 s. float int float 0~3.4*10^38 0~2147483647 0-100 Visible Y Counter Type SI Trigger Type 5.12 s. Data Type float Min/Max 0-100 Granularity Formula PrbDlTot/PrbD lCnt PrbUlTot/PrbU lCnt Hourly, Daily, Monthly Formula sum (PrbDlTot)/sum (PrbDlCnt) sum (PrbUlTot)/sum (PrbUlCnt) -

SAMSUNG Electronics Co., Ltd.

page 241 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PrbUlCnt PrbDlCu rrent PrbUlCu rrent

Unit count %

Description Collected PrbUl count DL PRB Current Usage for traffic -

Visible

Counter Type SI SI

Trigger Type 5.12 s 5.12 s

Data Type int float

Min/Max 0~2147483647 0~3.4*10^38 -

Granularity Formula -

Hourly, Daily, Monthly Formula

UL PRB Current Usage for traffic

SI

5.12 s

float

0~3.4*10^38

SAMSUNG Electronics Co., Ltd.

page 242 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

12.2 DL/UL Total PRB Usage


This section provides statistics data for usage rate (percentage) of the PRB on the downlink PDSCH and the uplink PUSCH among th e total PRB. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name TotPrbDl Unit % Description The resource used for the PDSCH/ PDCCH transmission among the total downlink resource TotPrbDlMin % Minimum value of resources used for the PDSCH/PDCCH transmission among the total downlink resources TotPrbDlMax % Maximum value of resources used for the PDSCH/PDCCH transmission among the total downlink resources TotPrbDlTot % The sum of collected TotPrbDl GAUGE 5.12 s float 0~3.4*10 ^38 GAUGE 5.12 s float 0~100 max (TotPrbDlMax) GAUGE 5.12 s float 0~100 min (TotPrbDlMin) Visible Y Counter Type GAUGE Trigger Type 5.12 s. Data Type float Min/Max 0-100 Granularity Formula TotPrbDlTot/ TotPrbDlCnt Hourly, Daily, Monthly Formula sum (TotPrbDlTot)/sum (TotPrbDlCnt)

SAMSUNG Electronics Co., Ltd.

page 243 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name TotPrbDlCnt

Unit count

Description Collected TotPrbDl count

Visible -

Counter Type GAUGE

Trigger Type 5.12 s

Data Type int

Min/Max 0~21474 83647

Granularity Formula -

Hourly, Daily, Monthly Formula

TotGbrPrbDl

Ratio of the resource used to transmit the GBR traffic against the total downlink resources.

GAUGE

5.12 s.

float

0-100

TotGbrPrbDl Tot/TotGbrPr bDlCnt

sum (TotGbrPrbDlTot)/ sum (TotGbrPrbDlCnt)

TotGbrPrbDl Min

Minimum value of resources used for the GBR traffic transmission among the total downlink resources

GAUGE

5.12 s

float

0~100

min (TotGbrPrbDlMin)

TotGbrPrbDl Max

Maximum value of resources used for the GBR traffic transmission among the total downlink resources

GAUGE

5.12 s

float

0~100

max (TotGbrPrbDlMax)

TotGbrPrbDlT ot TotGbrPrbDlC nt TotNGbrPrbDl

The sum of collected TotGbrPrbDl

GAUGE

5.12 s

float

0~3.4*10 ^38

count

Collected TotGbrPrbDl count

GAUGE

5.12 s

int

0~21474 83647

Ratio of the resource used to transmit the non-GBR traffic against the total downlink resources.

GAUGE

5.12 s.

float

0-100

TotNGbrPrb DlTot/TotNG brPrbDlCnt

sum (TotNGbrPrbDlTot)/ sum (TotNGbrPrbDlCnt)

TotNGbrPrbDl Min

Minimum value of resources used for the non-GBR traffic transmission among the total downlink resources

GAUGE

5.12 s

float

0~100

min (TotNGbrPrbDlMin)

TotNGbrPrbDl Max

Maximum value of resources used for the non-GBR traffic transmission among the total downlink resources

GAUGE

5.12 s

float

0~100

max (TotNGbrPrbDlMax)

SAMSUNG Electronics Co., Ltd.

page 244 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name TotNGbrPrbDl Tot TotNGbrPrbDl Cnt TotPrbUl

Unit %

Description The sum of collected TotNGbrPrbDl

Visible -

Counter Type GAUGE

Trigger Type 5.12 s

Data Type float

Min/Max 0~3.4*10 ^38

Granularity Formula -

Hourly, Daily, Monthly Formula

count

Collected TotNGbrPrbDl count

GAUGE

5.12 s

int

0~21474 83647

The resource used for the PUSCH transmission among the total uplink resource

GAUGE

5.12 s.

float

0-100

TotPrbUlTot/ TotPrbUlCnt

sum (TotPrbUlTot)/sum (TotPrbUlCnt)

TotPrbUlMin

Minimum value of resources used for the PUSCH transmission among the total uplink resources

GAUGE

5.12 s

float

0~100

min (TotPrbUlMin)

TotPrbUlMax

Maximum value of resources used for the PUSCH transmission among the total uplink resources

GAUGE

5.12 s

float

0~100

max (TotPrbUlMax)

TotPrbUlTot

The sum of collected TotPrbUl

GAUGE

5.12 s

float

0~3.4*10 ^38

TotPrbUlCnt

count

Collected TotPrbUl count

GAUGE

5.12 s

int

0~21474 83647

TotGbrPrbUl

Ratio of the resource used to transmit the GBR traffic against the total uplink resources.

GAUGE

5.12 s.

float

0-100

TotGbrPrbUl Tot/TotGbrPr bUlCnt

sum (TotGbrPrbUlTot)/ sum (TotGbrPrbUlCnt)

TotGbrPrbUl Min

Minimum value of resources used for the GBR traffic transmission among the total uplink resources

GAUGE

5.12 s

float

0~100

min (TotGbrPrbUlMin)

SAMSUNG Electronics Co., Ltd.

page 245 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name TotGbrPrbUl Max

Unit %

Description Maximum value of resources used for the GBR traffic transmission among the total uplink resources

Visible -

Counter Type GAUGE

Trigger Type 5.12 s

Data Type float

Min/Max 0~100

Granularity Formula -

Hourly, Daily, Monthly Formula max (TotGbrPrbUlMax)

TotGbrPrbUlT ot TotGbrPrbUlC nt TotNGbrPrbUl

The sum of collected TotGbrPrbUl

GAUGE

5.12 s

float

0~3.4*10 ^38

count

Collected TotGbrPrbUl count

GAUGE

5.12 s

int

0~21474 83647

Ratio of the resource used to transmit the non-GBR traffic against the total uplink resources.

GAUGE

5.12 s.

float

0-100

TotNGbrPrb UlTot/TotNG brPrbUlCnt

sum (TotNGbrPrbUlTot)/ sum (TotNGbrPrbUlCnt)

TotNGbrPrbUl Min

Minimum value of resources used for the non-GBR traffic transmission among the total uplink resources

GAUGE

5.12 s

float

0~100

min (TotNGbrPrbUlMin)

TotNGbrPrbUl Max

Maximum value of resources used for the non-GBR traffic transmission among the total uplink resources

GAUGE

5.12 s

float

0~100

max (TotNGbrPrbUlMax)

TotNGbrPrbUl Tot TotNGbrPrbUl Cnt TotPrbDlCurr ent TotPrbUlCurr ent

The sum of collected TotNGbrPrbUl

GAUGE

5.12 s

float

0~3.4*10 ^38

count

Collected TotNGbrPrbUl count

GAUGE

5.12 s

int

0~21474 83647

DL Total Current PRB Usage

GAUGE

5.12

float

0~100

UL Total Current PRB Usage

GAUGE

5.12 s

float

0~100

SAMSUNG Electronics Co., Ltd.

page 246 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

12.3 Cell Unavailable Time


This section provides statistics data for the average locked time and disabled time per unit time. Index
Name cNum Range 0~2 Description Cell Index

Type
Name CellUnavailableTimeLock Unit s Description Measures the lock time per measurement period. CellUnavailableTimeDown s Measures the disabled time per measurement period. Y CC 1 min. int 0-60*Period Visible Y Counter Type CC Trigger Type 1 min. Data Type int Min/Max 0-60*Period Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 247 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

13 S1SIG
S1 Application Protocol Signalling (S1SIG) provides information about UE-associated logical S1-connection establishment statistics. These statistics items are described in the following table.

13.1 UE-associated logical S1-connection establishment


This section provides statistics data for S1 Logical Connection Setup for each cell. When the Initial UE message is transmitted, it is c ounted as Attempt; when the Initial Context Setup Request message is received, it is counted as Success. A failure is counted when a failure or timeout occurs during the procedure and the applicable cause is recorded. Index
Name cNum mcID EstabCause Range 0~2 0~0 0~5 Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: relocated: Access by the UE due to handover Description

SAMSUNG Electronics Co., Ltd.

page 248 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Type
Name S1ConnEstabA tt S1ConnEstabS ucc S1ConnEstabF ail_CP_CC_FA IL count count Unit count Description UE logical S1 connection setup attempt count UE Logical S1 Connection Setup success count. A call is released due to reset notification (eNB failure or block restart) from ECMB or by the ECCB block during S1 connection. S1ConnEstabF ail_S1AP_CU_ FAIL S1ConnEstabF ail_S1AP_LINK _FAIL S1ConnEstabF ail_S1AP_SIG _FAIL S1ConnEstabF ail_S1AP_SIG _TO count A call is released due to S1AP signaling timeout (not received) during S1 connection. Y CC event int 0-2147483647 count A call is released due to receiving S1AP signaling during S1 connection. Y CC event int 0-2147483647 count count A call is released due to the S1AP specification cause during S1 connection. A call is released due to S1 SCTP link failure during S1 connection. Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 249 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE Initial UE Message MME S/GW

Attempt

Success

Initial Context Setup Request

RRC_CONNECTED

Figure 32. Collection Time for UE-associated Logical S1-Connection Establishment

SAMSUNG Electronics Co., Ltd.

page 250 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

13.2 S1 Connection Time


This section provides statistics on S1 setup time. Index
Name cNum mcID EstabCause 0~2 0~0 0~5 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) RRC Connection Establishment Cause 0: emergency: Emergency call connection 1: highPriorityAccess: Access by the UE with a specific access class 2: mt_Access: Access by the UE due to paging received 3: mo_Signaling: Access by the UE due to attach 4: mo_Data: Access by the UE due to service request 5: relocated: Access by the UE due to handover Description

Type
Name S1SigTime_ Avg S1SigTime_ Max S1SigTime_ Tot S1SigTime_ Cnt Unit ms ms ms count Description S1 connection average setup time Maximum setup time for S1 connection Accumulated setup time for S1 connection The number of S1SigTime_Avg called Visible Y Y Y Y Counter Type GAUGE GAUGE GAUGE GAUGE Trigger Type event event event event Data Type float float float int Min/Max 0-3.4*10^38 0-3.4*10^38 0-3.4*10^38 0-2147483647 Granularity Formula S1SigTime_Tot/ S1SigTime_Cnt Hourly, Daily, Monthly Formula sum (S1SigTime_Tot)/ sum (S1SigTime_Cnt) max (S1SigTime_Max) -

SAMSUNG Electronics Co., Ltd.

page 251 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

14 PAG
PAG is paging statistics on the number of paging attempts by the RRC and number of paging messages that are discarded when the R LC cannot process paging messages upon receipt due to insufficient capacity. The RLC can save up to 1,024 paging messages in each cell.

14.1 Paging Performance


It collects statistics data for paging. The eNB collects the statistics data for the paging attempt for each cell of the base station made by the MMEs paging request. Also, it collects the number of the discarded paging messages that were not processed by the eNB for each cell. The paging for both of system information update and ETWA indication is not included. The eNB, which is an access network, does n ot collect the statistics data for the paging responses which are made through NAS signaling. Index
Name cNum Range 0~2 Description Index of the cell to which RRC paging will be transmitted.

Type
Name DiscardedNbr AttPaging Unit count count Description Paging record count discarded in the eNB Paging transmission attempt count Visible Y Y Counter Type CC CC Trigger Type 10 s. event Data Type int int Min/Max 0-2147483647 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 252 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Collection Time
UE eNB RRC_IDLE Paging Request Paging Paging 1 Attempt MME S/GW

Figure 33. Collection Time for Paging Performance

SAMSUNG Electronics Co., Ltd.

page 253 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

15 Power
15.1 Power
This section provides statistics data for average interference over thermal noise for each PRB, the average thermal noise for each cell, the average RSSI for each cell, and the average RSSI for each antenna. Index
Name cNum Range 0~2 Description Cell Index

Type
Name InterferencePo wer Unit dBm Description Average interference over thermal noise for each PRB The sum of collected InterferencePower Collected InterferencePower count Average Thermal Noise Visible Y Counter Type SI Trigger Type 5.12 s. Data Type float Min/Max -1000-1000 Granularity Formula InterferencePowerTot/ InterferencePowerCnt Hourly, Daily, Monthly Formula sum (InterferencePowerTot)/ sum (InterferencePowerCnt) sum (ThermalNoisePowerTot)/ sum (ThermalNoisePowerCnt)

InterferencePo werTot InterferencePo werCnt ThermalNoise Power

dBm count dBm

SI SI SI

5.12 s 5.12 s 5.12 s.

float int float

-3.4*10^38 ~3.4*10^38 0~2147483 647 -1000-1000

ThermalNoisePowerTo t/ThermalNoisePower Cnt

SAMSUNG Electronics Co., Ltd.

page 254 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ThermalNoise PowerTot ThermalNoise PowerCnt RssiOverPath RssiOverPathT ot RssiOverPath Cnt RssiPath0 RssiPath0Tot RssiPath0Cnt RssiPath1 RssiPath1Tot RssiPath1Cnt RssiPath0_Cur rent RssiPath1_Cur rent

Unit dBm count dBm dBm count dBm dBm count dBm dBm count dBm dBm

Description The sum of collected ThermalNoisePower Collected ThermalNoisePower count Average RSSI for each antenna The sum of collected RssiOverPath Collected RssiOverPath count Average RSSI of Antenna #0 The sum of collected RssiPath0 Collected RssiPath0 count Average RSSI of Antenna #1 The sum of collected RssiPath1 Collected RssiPath1 count The most recently collected RssiPath0 The most recently collected RssiPath1

Visible Y Y Y -

Counter Type SI SI SI SI SI SI SI SI SI SI SI SI SI

Trigger Type 5.12 s 5.12 s 5.12 s. 5.12 s 5.12 s 5.12 s. 5.12 s 5.12 s 5.12 s. 5.12 s 5.12 s 5.12 s 5.12 s

Data Type float int float float int float float int float float int float float

Min/Max -3.4*10^38 ~3.4*10^38 0~2147483 647 -1000-1000 -3.4*10^38 ~3.4*10^38 0~2147483 647 -1000-1000 -3.4*10^38 ~3.4*10^38 0~2147483 647 -1000-1000 -3.4*10^38 ~3.4*10^38 0~2147483 647 -3.4*10^38 ~3.4*10^38 -3.4*10^38 ~3.4*10^38 -

Granularity Formula -

Hourly, Daily, Monthly Formula

RssiOverPathTot/Rssi OverPathCnt RssiPath0Tot/RssiPath 0Cnt RssiPath1Tot/RssiPath 1Cnt -

sum (RssiOverPathTot)/ sum (RssiOverPathCnt) sum (RssiPath0Tot)/sum (RssiPath0Cnt) sum (RssiPath1Tot)/sum (RssiPath1Cnt) max (RssiPath0_Current) max (RssiPath1_Current)

SAMSUNG Electronics Co., Ltd.

page 255 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

15.2 RNTP of own cell


This section provides statistics data for Relative Narrowband TX Power (RNTP) value for each PRB. RNTP is defined as follows, and it has the value 0 or 1.

RNTP (PRB #k) = 0, if PRB #k; the maximum Tx power guarantees the level below the given threshold. RNTP (PRB #k) = 1, if PRB #k; the maximum Tx power does not guarantee the level below the given threshold

Index
Name cNum Range 0~2 Description Cell Index

Type
Name RntpOwnCell_PRB0 RntpOwnCell_PRB1 RntpOwnCell_PRB2 RntpOwnCell_PRB3 RntpOwnCell_PRB4 RntpOwnCell_PRB5 RntpOwnCell_PRB6 RntpOwnCell_PRB7 RntpOwnCell_PRB8 RntpOwnCell_PRB9 Unit indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator Description RNTP of downlink PRB #0. RNTP of downlink PRB #1. RNTP of downlink PRB #2. RNTP of downlink PRB #3. RNTP of downlink PRB #4. RNTP of downlink PRB #5. RNTP of downlink PRB #6. RNTP of downlink PRB #7. RNTP of downlink PRB #8. RNTP of downlink PRB #9. Visible Y Y Y Y Y Y Y Y Y Y Counter Type CC CC CC CC CC CC CC CC CC CC Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. Data Type int int int int int int int int int int Min/ Max 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 256 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RntpOwnCell_PRB10 RntpOwnCell_PRB11 RntpOwnCell_PRB12 RntpOwnCell_PRB13 RntpOwnCell_PRB14 RntpOwnCell_PRB15 RntpOwnCell_PRB16 RntpOwnCell_PRB17 RntpOwnCell_PRB18 RntpOwnCell_PRB19 RntpOwnCell_PRB20 RntpOwnCell_PRB21 RntpOwnCell_PRB22 RntpOwnCell_PRB23 RntpOwnCell_PRB24 RntpOwnCell_PRB25 RntpOwnCell_PRB26 RntpOwnCell_PRB27 RntpOwnCell_PRB28 RntpOwnCell_PRB29 RntpOwnCell_PRB30 RntpOwnCell_PRB31

Unit indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator

Description RNTP of downlink PRB #10. RNTP of downlink PRB #11. RNTP of downlink PRB #12. RNTP of downlink PRB #13. RNTP of downlink PRB #14. RNTP of downlink PRB #15. RNTP of downlink PRB #16. RNTP of downlink PRB #17. RNTP of downlink PRB #18. RNTP of downlink PRB #19. RNTP of downlink PRB #20. RNTP of downlink PRB #21. RNTP of downlink PRB #22. RNTP of downlink PRB #23. RNTP of downlink PRB #24. RNTP of downlink PRB #25. RNTP of downlink PRB #26. RNTP of downlink PRB #27. RNTP of downlink PRB #28. RNTP of downlink PRB #29. RNTP of downlink PRB #30. RNTP of downlink PRB #31.

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/ Max 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 257 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RntpOwnCell_PRB32 RntpOwnCell_PRB33 RntpOwnCell_PRB34 RntpOwnCell_PRB35 RntpOwnCell_PRB36 RntpOwnCell_PRB37 RntpOwnCell_PRB38 RntpOwnCell_PRB39 RntpOwnCell_PRB40 RntpOwnCell_PRB41 RntpOwnCell_PRB42 RntpOwnCell_PRB43 RntpOwnCell_PRB44 RntpOwnCell_PRB45 RntpOwnCell_PRB46 RntpOwnCell_PRB47 RntpOwnCell_PRB48 RntpOwnCell_PRB49 RntpOwnCell_PRB50 RntpOwnCell_PRB51 RntpOwnCell_PRB52 RntpOwnCell_PRB53

Unit indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator

Description RNTP of downlink PRB #32. RNTP of downlink PRB #33. RNTP of downlink PRB #34. RNTP of downlink PRB #35. RNTP of downlink PRB #36. RNTP of downlink PRB #37. RNTP of downlink PRB #38. RNTP of downlink PRB #39. RNTP of downlink PRB #40. RNTP of downlink PRB #41. RNTP of downlink PRB #42. RNTP of downlink PRB #43. RNTP of downlink PRB #44. RNTP of downlink PRB #45. RNTP of downlink PRB #46. RNTP of downlink PRB #47. RNTP of downlink PRB #48. RNTP of downlink PRB #49. RNTP of downlink PRB #50. RNTP of downlink PRB #51. RNTP of downlink PRB #52. RNTP of downlink PRB #53.

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/ Max 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 258 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RntpOwnCell_PRB54 RntpOwnCell_PRB55 RntpOwnCell_PRB56 RntpOwnCell_PRB57 RntpOwnCell_PRB58 RntpOwnCell_PRB59 RntpOwnCell_PRB60 RntpOwnCell_PRB61 RntpOwnCell_PRB62 RntpOwnCell_PRB63 RntpOwnCell_PRB64 RntpOwnCell_PRB65 RntpOwnCell_PRB66 RntpOwnCell_PRB67 RntpOwnCell_PRB68 RntpOwnCell_PRB69 RntpOwnCell_PRB70 RntpOwnCell_PRB71 RntpOwnCell_PRB72 RntpOwnCell_PRB73 RntpOwnCell_PRB74 RntpOwnCell_PRB75

Unit indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator

Description RNTP of downlink PRB #54. RNTP of downlink PRB #55. RNTP of downlink PRB #56. RNTP of downlink PRB #57. RNTP of downlink PRB #58. RNTP of downlink PRB #59. RNTP of downlink PRB #60. RNTP of downlink PRB #61. RNTP of downlink PRB #62. RNTP of downlink PRB #63. RNTP of downlink PRB #64. RNTP of downlink PRB #65. RNTP of downlink PRB #66. RNTP of downlink PRB #67. RNTP of downlink PRB #68. RNTP of downlink PRB #69. RNTP of downlink PRB #70. RNTP of downlink PRB #71. RNTP of downlink PRB #72. RNTP of downlink PRB #73. RNTP of downlink PRB #74. RNTP of downlink PRB #75.

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/ Max 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 259 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RntpOwnCell_PRB76 RntpOwnCell_PRB77 RntpOwnCell_PRB78 RntpOwnCell_PRB79 RntpOwnCell_PRB80 RntpOwnCell_PRB81 RntpOwnCell_PRB82 RntpOwnCell_PRB83 RntpOwnCell_PRB84 RntpOwnCell_PRB85 RntpOwnCell_PRB86 RntpOwnCell_PRB87 RntpOwnCell_PRB88 RntpOwnCell_PRB89 RntpOwnCell_PRB90 RntpOwnCell_PRB91 RntpOwnCell_PRB92 RntpOwnCell_PRB93 RntpOwnCell_PRB94 RntpOwnCell_PRB95 RntpOwnCell_PRB96 RntpOwnCell_PRB97

Unit indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator indicator

Description RNTP of downlink PRB #76. RNTP of downlink PRB #77. RNTP of downlink PRB #78. RNTP of downlink PRB #79. RNTP of downlink PRB #80. RNTP of downlink PRB #81. RNTP of downlink PRB #82. RNTP of downlink PRB #83. RNTP of downlink PRB #84. RNTP of downlink PRB #85. RNTP of downlink PRB #86. RNTP of downlink PRB #87. RNTP of downlink PRB #88. RNTP of downlink PRB #89. RNTP of downlink PRB #90. RNTP of downlink PRB #91. RNTP of downlink PRB #92. RNTP of downlink PRB #93. RNTP of downlink PRB #94. RNTP of downlink PRB #95. RNTP of downlink PRB #96. RNTP of downlink PRB #97.

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/ Max 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 260 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RntpOwnCell_PRB98 RntpOwnCell_PRB99

Unit indicator indicator

Description RNTP of downlink PRB #98. RNTP of downlink PRB #99.

Visible Y Y

Counter Type CC CC

Trigger Type 5.12 s. 5.12 s.

Data Type int int

Min/ Max 0-1 0-1

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 261 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

15.3 RRH_RSSI
Collects the statistics data for the Received Signal Strength Indicator (RSSI) values for each RRH path. Index
Name BID RuPort Cascade RSSIPath 0~0 0~2 0~0 0~7 Range Board ID Ru Port Number Cascade ID RSSI Path ID Description

Type
Name RrhRssiAvg Unit dBm Description The average values of RSSI for each RRH path Visible Y Counter Type GAUGE Trigger Type 10 s Data Type float Min/Max -1000~1000 Granularity Formula 10*(log10 (RrhRssiTot/Rr hRssiCnt)-12) RrhRssiMax dBm The maximum values of RSSI for each RRH path RrhRssi dBm The most recently collected RSSI values for each RRH path RrhRssiTot mW*10^12 The total sum of the RSSI linear values for each RRH path RrhRssiCnt count Number of times that the RSSI values were collected for each RRH path Y GAUGE 10 s int Y GAUGE 10 s float -3.4*10^38 ~3.4*10^38 0~2147483647 Y GAUGE 10 s float -1000~1000 max (RrhRssi) Y GAUGE 10 s float -1000~1000 Hourly, Daily, Monthly Formula 10*(log10 (sum (RrhRssiTot)/sum (RrhRssiCnt))-12) max (RrhRssiMax)

SAMSUNG Electronics Co., Ltd.

page 262 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

16 RA
This section provides statistics data for Random Access Preamble are provided. These statistics items are described in the following tab le.

16.1 Random Access Preambles


It collects the number of the high-speed monitoring result and the RACH preamble. For the High Speed Monitoring, estimates the moving speed of the terminals within the cell and counts the terminals which speed is d etermined as high. Also, it collects the number of detected Dedicated Preambles, Contention-based Group A Preambles, and Contentionbased Group B Preambles, then collects the average per second of the detected preambles. Index
Name cNum Range 0~2 Description Cell Index

Type
Name HighSpeedMonito ring NoofHighSpeed count Unit count Description The number of UEs which are monitored for moving speed The number of high speed UEs which are monitored DedicatedPream bles DedicatedPream count count The number of detected dedicated preambles. The number of failures to get Y CC event int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 5.12 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 263 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name blesAssignFail

Unit

Description dedicated preamble allocation after requesting the dedicated preamble from the RRC to the MAC

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

Randomlyselecte dpreamblesLow

count

The number of the preambles belonging to Group A among the detected contention based preambles

CC

5.12 s.

int

0-2147483647

Randomlyselecte dpreamblesHigh

count

The number of the preambles belonging to Group B among the detected contention based preambles

CC

5.12 s.

int

0-2147483647

RACHUsage

count

Average number of detected preambles

SI

5.12 s.

float

0-3.4*10^38

RACHUsag eTot/RACH UsageCnt

sum (RACHUsageTot)/ sum (RACHUsageCnt)

RACHUsageTot RACHUsageCnt

count count

The sum of collected RACHUsage Collected RACHUsage count

SI SI

5.12 s 5.12 s

float int

0~3.4*10^38 0~2147483647

SAMSUNG Electronics Co., Ltd.

page 264 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

17 HARQ
The HARQ provides the DL/UL transmission statistics. These statistics items are described in the following table.

17.1 DL/UL Transmission


This section provides statistics data for each HARQ transmission for PDSCH/PUSCH and the Block Error Rate (BLER) information. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name DlResidualBLE R_Retrans0 Unit % Description PDSCH BLER for the initial HARQ transmission Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-100 Granularity Formula (DlTransmission_Re trans1/DlTransmissi on_Retrans0)*100 Hourly, Daily, Monthly Formula (sum (DlTransmission_ Retrans1)/sum (DlTransmission_Retra ns0))*100 DlResidualBLE R_Retrans1 % PDSCH BLER for the first HARQ retransmission Y OW Period float 0-100 (DlTransmission_Re trans2/DlTransmissi on_Retrans1)*100 (sum (DlTransmission_ Retrans2)/sum (DlTransmission_Retra ns1))*100 DlResidualBLE R_Retrans2 % PDSCH BLER for the second HARQ Y OW Period float 0-100 (DlTransmission_Re trans3/DlTransmissi (sum (DlTransmission_ Retrans3)/sum

SAMSUNG Electronics Co., Ltd.

page 265 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description retransmission

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula on_Retrans2)*100

Hourly, Daily, Monthly Formula (DlTransmission_Retra ns2))*100

DlResidualBLE R_Retrans3

PDSCH BLER for the third HARQ retransmission

OW

Period

float

0-100

(DlTransmission_Na cked_Retrans3/DlTr ansmission_Retrans 3)*100

(sum (DlTransmission_ Nacked_Retrans3)/ sum (DlTransmission_ Retrans3))*100 (sum (UlTransmission_ Retrans1)/sum (UlTransmission_Retra ns0))*100

UlResidualBLE R_Retrans0

PUSCH BLER for the initial HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans1/UlTransmissi on_Retrans0)*100

UlResidualBLE R_Retrans1

PUSCH BLER for the first HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans2/UlTransmissi on_Retrans1)*100

(sum (UlTransmission_ Retrans2)/sum (UlTransmission_Retra ns1))*100

UlResidualBLE R_Retrans2

PUSCH BLER for the second HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans3/UlTransmissi on_Retrans2)*100

(sum (UlTransmission_ Retrans3)/sum (UlTransmission_Retra ns2))*100

UlResidualBLE R_Retrans3

PUSCH BLER for the third HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Na cked_Retrans27/UlT ransmission_Retran s3)*100

(sum (UlTransmission_ Nacked_Retrans27)/ sum (UlTransmission_ Retrans3))*100 (sum (UlTransmission_ Retrans5)/sum (UlTransmission_Retra ns4))*100

UlResidualBLE R_Retrans4

PUSCH BLER for the fourth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans5/UlTransmissi on_Retrans4)*100

SAMSUNG Electronics Co., Ltd.

page 266 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlResidualBLE R_Retrans5

Unit %

Description PUSCH BLER for the fifth HARQ retransmission

Visible Y

Counter Type OW

Trigger Type Period

Data Type float

Min/Max 0-100

Granularity Formula (UlTransmission_Re trans6/UlTransmissi on_Retrans5)*100

Hourly, Daily, Monthly Formula (sum (UlTransmission_ Retrans6)/sum (UlTransmission_Retra ns5))*100

UlResidualBLE R_Retrans6

PUSCH BLER for the sixth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans7/UlTransmissi on_Retrans6)*100

(sum (UlTransmission_ Retrans7)/sum (UlTransmission_Retra ns6))*100

UlResidualBLE R_Retrans7

PUSCH BLER for the seventh HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans8/UlTransmissi on_Retrans7)*100

(sum (UlTransmission_ Retrans8)/sum (UlTransmission_Retra ns7))*100

UlResidualBLE R_Retrans8

PUSCH BLER for the eighth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans9/UlTransmissi on_Retrans8)*100

(sum (UlTransmission_ Retrans9)/sum (UlTransmission_Retra ns8))*100

UlResidualBLE R_Retrans9

PUSCH BLER for the ninth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Re trans10/UlTransmis sion_Retrans9)*100

(sum (UlTransmission_ Retrans10)/sum (UlTransmission_Retra ns9))*100

UlResidualBLE R_Retrans10

PUSCH BLER for the tenth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans11/UlTransmissi on_Retrans10)*100

(sum (UlTransmission_ Retrans11)/sum (UlTransmission_Retra ns10))*100

UlResidualBLE R_Retrans11

PUSCH BLER for the eleventh HARQ

OW

Period

float

0-100

(UlTransmission_Ret rans12/UlTransmissi

(sum (UlTransmission_ Retrans12)/sum

SAMSUNG Electronics Co., Ltd.

page 267 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description retransmission

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula on_Retrans11)*100

Hourly, Daily, Monthly Formula (UlTransmission_Retra ns11))*100

UlResidualBLE R_Retrans12

PUSCH BLER for the twelfth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans13/UlTransmissi on_Retrans12)*100

(sum (UlTransmission_ Retrans13)/sum (UlTransmission_Retra ns12))*100

UlResidualBLE R_Retrans13

PUSCH BLER for the thirteenth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans14/UlTransmissi on_Retrans13)*100

(sum (UlTransmission_ Retrans14)/sum (UlTransmission_Retra ns13))*100

UlResidualBLE R_Retrans14

PUSCH BLER for the fourteenth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans15/UlTransmissi on_Retrans14)*100

(sum (UlTransmission_ Retrans15)/sum (UlTransmission_Retra ns14))*100

UlResidualBLE R_Retrans15

PUSCH BLER for the fifteenth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans16/UlTransmissi on_Retrans15)*100

(sum (UlTransmission_ Retrans16)/sum (UlTransmission_Retra ns15))*100

UlResidualBLE R_Retrans16

PUSCH BLER for the sixteenth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans17/UlTransmissi on_Retrans16)*100

(sum (UlTransmission_ Retrans17)/sum (UlTransmission_Retra ns16))*100

UlResidualBLE R_Retrans17

PUSCH BLER for the seventeenth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans18/UlTransmissi on_Retrans17)*100

(sum (UlTransmission_ Retrans18)/sum (UlTransmission_Retra ns17))*100

SAMSUNG Electronics Co., Ltd.

page 268 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlResidualBLE R_Retrans18

Unit %

Description PUSCH BLER for the eighteenth HARQ retransmission

Visible Y

Counter Type OW

Trigger Type Period

Data Type float

Min/Max 0-100

Granularity Formula (UlTransmission_Ret rans19/UlTransmissi on_Retrans18)*100

Hourly, Daily, Monthly Formula (sum (UlTransmission_ Retrans19)/sum (UlTransmission_Retra ns18))*100

UlResidualBLE R_Retrans19

PUSCH BLER for the nineteenth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans20/UlTransmissi on_Retrans19)*100

(sum (UlTransmission_ Retrans20)/sum (UlTransmission_Retra ns19))*100

UlResidualBLE R_Retrans20

PUSCH BLER for the twentieth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans21/UlTransmissi on_Retrans20)*100

(sum (UlTransmission_ Retrans21)/sum (UlTransmission_Retra ns20))*100

UlResidualBLE R_Retrans21

PUSCH BLER for the twenty first HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans22/UlTransmissi on_Retrans21)*100

(sum (UlTransmission_ Retrans22)/sum (UlTransmission_Retra ns21))*100

UlResidualBLE R_Retrans22

PUSCH BLER for the twenty second HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans23/UlTransmissi on_Retrans22)*100

(sum (UlTransmission_ Retrans23)/sum (UlTransmission_Retra ns22))*100

UlResidualBLE R_Retrans23

PUSCH BLER for the twenty third HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans24/UlTransmissi on_Retrans23)*100

(sum (UlTransmission_ Retrans24)/sum (UlTransmission_Retra ns23))*100

UlResidualBLE R_Retrans24

PUSCH BLER for the twenty fourth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans25/UlTransmissi

(sum (UlTransmission_ Retrans25)/sum

SAMSUNG Electronics Co., Ltd.

page 269 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula on_Retrans24)*100

Hourly, Daily, Monthly Formula (UlTransmission_Retra ns24))*100

UlResidualBLE R_Retrans25

PUSCH BLER for the twenty fifth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans26/UlTransmissi on_Retrans25)*100

(sum (UlTransmission_ Retrans26)/sum (UlTransmission_Retra ns25))*100

UlResidualBLE R_Retrans26

PUSCH BLER for the twenty sixth HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Ret rans27/UlTransmissi on_Retrans26)*100

(sum (UlTransmission_ Retrans27)/sum (UlTransmission_Retra ns26))*100

UlResidualBLE R_Retrans27

PUSCH BLER for the twenty seventh HARQ retransmission

OW

Period

float

0-100

(UlTransmission_Na cked_Retrans27/UlT ransmission_Retran s27)*100

(sum (UlTransmission_ Nacked_Retrans27)/su m (UlTransmission_ Retrans27))*100 -

DlTransmission _Retrans0 DlTransmission _Retrans1 DlTransmission _Retrans2 DlTransmission _Retrans3 DlTransmission _Nacked_Retr ans3

count

Number of initial PDSCH HARQ transmissions

CC

5.12 s.

int

0-2147483647

count

Number of first PDSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of second PDSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of third PDSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of third PDSCH HARQ retransmission failures

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 270 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlTransmission _Retrans0 UlTransmission _Retrans1 UlTransmission _Retrans2 UlTransmission _Retrans3 UlTransmission _Retrans4 UlTransmission _Retrans5 UlTransmission _Retrans6 UlTransmission _Retrans7 UlTransmission _Retrans8 UlTransmission _Retrans9 UlTransmission _Retrans10 UlTransmission _Retrans11

Unit count

Description Number of initial PUSCH HARQ transmissions

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-2147483647 -

Granularity Formula

Hourly, Daily, Monthly Formula -

count

Number of first PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of second PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of third PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of fourth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of fifth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of sixth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of seventh PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of eighth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of ninth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of tenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of eleventh PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 271 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlTransmission _Retrans12 UlTransmission _Retrans13

Unit count

Description Number of twelfth PUSCH HARQ retransmissions

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-2147483647 -

Granularity Formula

Hourly, Daily, Monthly Formula -

count

Number of thirteenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans14

count

Number of fourteenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans15 UlTransmission _Retrans16 UlTransmission _Retrans17

count

Number of fifteenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of sixteenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of seventeenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans18

count

Number of eighteenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans19

count

Number of nineteenth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans20 UlTransmission _Retrans21

count

Number of twentieth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Number of twenty first PUSCH HARQ

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 272 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description retransmissions

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

UlTransmission _Retrans22

count

Number of twenty second PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans23

count

Number of twenty third PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans24

count

Number of twenty fourth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans25

count

Number of twenty fifth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans26

count

Number of twenty sixth PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Retrans27

count

Number of twenty seventh PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

UlTransmission _Nacked_Retr ans27 DlResidualBLE R_RetransMin DlResidualBLE

count

Number of twenty seventh PUSCH HARQ retransmissions

CC

5.12 s.

int

0-2147483647

count

Minimum value of DlResidualBLER_Retrans

OW

Period

int

0-2147483647

min (DlResidualBLER_ RetransMin)

count

Maximum value of

OW

Period

int

0-2147483647

max (DlResidualBLER_

SAMSUNG Electronics Co., Ltd.

page 273 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name R_RetransMax DlResidualBLE R_RetransAvg

Unit

Description DlResidualBLER_Retrans

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula RetransMax)

ratio

Average of distribution for DlResidualBLER_Retrans Average of distribution for DlTransmission_Retrans

OW

Period

float

0-3.4*10 ^38

(DlTransmission_Re trans1+DlTransmissi on_Retrans2+DlTra nsmission_Retrans3 )/DlTransmission_R etrans0

(sum (DlTransmission_ Retrans1)+sum (DlTransmission_Retra ns2)+sum (DlTransmission_Retra ns3))/sum (DlTransmission_Retra ns0)

UlResidualBLE R_RetransMin UlResidualBLE R_RetransMax UlResidualBLE R_RetransAvg

count

Minimum value of UlResidualBLER_Retrans

OW

Period

int

0-2147483647

min (UlResidualBLER_ RetransMin)

count

Maximum value of UlResidualBLER_Retrans

OW

Period

int

0-2147483647

max (UlResidualBLER_ RetransMax)

ratio

Average of distribution for UlResidualBLER_Retrans Average of distribution for UlTransmission_Retrans

OW

Period

float

0-3.4*10^38

(UlTransmission_Re trans1+UlTransmissi on_Retrans2+UlTra nsmission_Retrans3 +UlTransmission_R etrans4+UlTransmis sion_Retrans5+UlTr ansmission_Retrans 6+UlTransmission_ Retrans7+UlTransm ission_Retrans8+Ul Transmission_Retra ns9+UlTransmission

(sum (UlTransmission_ Retrans1)+sum (UlTransmission_Retra ns2)+sum (UlTransmission_Retra ns3)+sum (UlTransmission_Retra ns4)+sum (UlTransmission_Retra ns5)+sum (UlTransmission_Retra ns6)+sum (UlTransmission_Retra

SAMSUNG Electronics Co., Ltd.

page 274 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula _Retrans10+UlTran smission_Retrans11 +UlTransmission_R etrans12+UlTransmi ssion_Retrans13+Ul Transmission_Retra ns14+UlTransmissio n_Retrans15+UlTra nsmission_Retrans1 6+UlTransmission_ Retrans17+UlTrans mission_Retrans18 +UlTransmission_R etrans19+UlTransmi ssion_Retrans20+Ul Transmission_Retra ns21+UlTransmissio n_Retrans22+UlTra nsmission_Retrans2 3+UlTransmission_ Retrans24+UlTrans mission_Retrans25 +UlTransmission_R etrans26+UlTransmi ssion_Retrans27)/Ul Transmission_Retra ns0

Hourly, Daily, Monthly Formula ns7)+sum (UlTransmission_Retra ns8)+sum (UlTransmission_Retra ns9)+sum (UlTransmission_Retra ns10)+sum (UlTransmission_Retra ns11)+sum (UlTransmission_Retra ns12)+sum (UlTransmission_Retra ns13)+sum (UlTransmission_Retra ns14) +sum (UlTransmission_Retra ns15)+sum (UlTransmission_Retra ns16)+sum (UlTransmission_Retra ns17)+sum (UlTransmission_Retra ns18)+sum (UlTransmission_Retra ns19)+sum (UlTransmission_Retra ns20)+sum

SAMSUNG Electronics Co., Ltd.

page 275 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula (UlTransmission_Retra ns21)+sum (UlTransmission_Retra ns22)+sum (UlTransmission_Retra ns23)+sum (UlTransmission_Retra ns24)+sum (UlTransmission_Retra ns25)+sum (UlTransmission_Retra ns26)+sum (UlTransmission_Retra ns27))/sum (UlTransmission_Retra ns0)

DlResidualBLE R_RetransNak

PDSCH BLER for HARQ Nak

OW

Period

float

0-100

DlTransmission_Na cked_Retrans3/DlTr ansmission_Retrans 0*100

sum (DlTransmission_ Nacked_Retrans3)/su m (DlTransmission_ Retrans0)*100 sum (UlTransmission_ Nacked_Retrans27)/su m (UlTransmission_ Retrans0)*100

UlResidualBLE R_RetransNak

HARQ Nak PUSCH BLER

OW

Period

float

0-100

UlTransmission_Na cked_Retrans27/UlT ransmission_Retran s0*100

SAMSUNG Electronics Co., Ltd.

page 276 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

18 Timing Alignment
TA statistics are based on values transmitted up by the MAC when the RRC Connection Request message is received. The timing adv ance value gets smaller as the distance between the UE and the eNB gets closer.

18.1 Timing Alignment


Collects the TA statistics for each cell. The TA is collected in the unit of 16Ts when the RRC ConnectionRequest message is received from the MAC. Index
Name cNum mcID 0~2 0~0 Range Serving Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name TimeAdvanceSection0 Unit count Description distance (meter): 0~200, 16TS: from 0 to 2 TimeAdvanceSection1 count distance (meter): 201~400, 16TS: from 3 to 5 TimeAdvanceSection2 count distance (meter): 401~600, 16TS: from 6 to 7 TimeAdvanceSection3 count distance (meter): 601~800, Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 277 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description 16TS: from 8 to 10

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

TimeAdvanceSection4

count

distance (meter): 801~1000, 16TS: from 11 to 12

CC

event

int

0~2147483647

TimeAdvanceSection5

count

distance (meter): 1001~1200, 16TS: from 13 to 15

CC

event

int

0~2147483647

TimeAdvanceSection6

count

distance (meter): 1201~1400, 16TS: from 16 to 17

CC

event

int

0~2147483647

TimeAdvanceSection7

count

distance (meter): 1401~1600, 16TS: from 18 to 20

CC

event

int

0~2147483647

TimeAdvanceSection8

count

distance (meter): 1601~1800, 16TS: from 21 to 22

CC

event

int

0~2147483647

TimeAdvanceSection9

count

distance (meter): 1801~2000, 16TS: from 23 to 25

CC

event

int

0~2147483647

TimeAdvanceSection10

count

distance (meter): 2001~2500, 16TS: from 26 to 31

CC

event

int

0~2147483647

TimeAdvanceSection11

count

distance (meter): 2501~3000, 16TS: from 32 to 38

CC

event

int

0~2147483647

TimeAdvanceSection12

count

distance (meter): 3001~3500, 16TS: from 39 to 44

CC

event

int

0~2147483647

TimeAdvanceSection13

count

distance (meter): 3501~4000, 16TS: from 45 to 50

CC

event

int

0~2147483647

TimeAdvanceSection14

count

distance (meter): 4001~5000, 16TS: from 51 to 63

CC

event

int

0~2147483647

TimeAdvanceSection15

count

distance (meter): 5001~6000,

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 278 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description 16TS: from 64 to 76

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

TimeAdvanceSection16

count

distance (meter): 6001~7000, 16TS: from 77 to 88

CC

event

int

0~2147483647

TimeAdvanceSection17

count

distance (meter): 7001~8000, 16TS: from 89 to 101

CC

event

int

0~2147483647

TimeAdvanceSection18

count

distance (meter): 8001~9000, 16TS: from 102 to 114

CC

event

int

0~2147483647

TimeAdvanceSection19

count

distance (meter): 9001~ 10000, 16TS: from 115 to 126

CC

event

int

0~2147483647

TimeAdvanceSection20

count

distance (meter): 10001~, 16TS: from 127 to 1282

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 279 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19 AMC
AMC provides MIMO performance, MCS performance, DL MCS, DL LAYER, DL CQI, DL PMI, DL RI, and DL ACK/NACK/DTX r atio statistics. These statistics items are described in the following table.

19.1 MIMO Performance


This section provides statistics data for Block Error Rate (BLER) information for each layer for PUSCH/PDSCH. Index
Name cNum mcID DL Layer 0~2 0~0 1~4 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Layer (data stream count) 1: 1 stream 2: 2 streams 3: 3 streams 4: 4 streams Description

Type
Name PdschBLERper Layer Unit % Description PDSCH BLER for each layer Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-100 Granularity Formula PdschBLERpe rLayerTot/ PdschBLERpe rLayerCnt*100 sum (PdschBLERperLayerTot)/ sum (PdschBLERperLayerCnt) *100 Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 280 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdschBLERper LayerTot PdschBLERper LayerCnt PuschBLERper Layer

Unit count

Description PDSCH error count for each layer (all errors)

Visible -

Counter Type CC

Trigger Type 5s

Data Type float

Min/Max 0~3.4*10^38 -

Granularity Formula -

Hourly, Daily, Monthly Formula

count

Total PDSCH count for each layer

CC

5s

int

0~2147483647

PUSCH BLER for each layer

OW

Period

float

0-100

PuschBLERpe rLayerTot/ PuschBLERpe rLayerCnt*100

sum (PuschBLERperLayerTot)/ sum (PuschBLERperLayerCnt) *100

PuschBLERper LayerTot PuschBLERper LayerCnt

count

PUSCH error count for each layer (all errors)

CC

5s

float

0~3.4*10^38

count

Total PUSCH count for each layer

CC

5s

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 281 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19.2 MCS Performance


It provides information about PUSCHs Block Error Rate (BLER), the number of allocated PRBs and the number of transmissions for each MCS. For the PDSCH, it collects the Block Error Rate (BLER) and the number of allocated PRBs. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name PdschBLERper MCS0 Unit % Description PDSCH BLER transmitted to MCS 0 Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-100 Granularity Formula PdschBLERperMCS0_ Tot/PdschBLERperMC S0_Cnt*100 Hourly, Daily, Monthly Formula sum (PdschBLERperMCS0_Tot)/ sum (PdschBLERperMCS0_Cnt) *100 PdschBLERper MCS1 % PDSCH BLER transmitted to MCS 1 Y OW Period float 0-100 PdschBLERperMCS1_ Tot/PdschBLERperMC S1_Cnt*100 sum (PdschBLERperMCS1_Tot)/ sum (PdschBLERperMCS1_Cnt) *100 PdschBLERper MCS2 % PDSCH BLER transmitted to MCS 2 Y OW Period float 0-100 PdschBLERperMCS2_ Tot/PdschBLERperMC S2_Cnt*100 sum (PdschBLERperMCS2_Tot)/ sum (PdschBLERperMCS2_Cnt)*

SAMSUNG Electronics Co., Ltd.

page 282 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula 100

PdschBLERper MCS3

PDSCH BLER transmitted to MCS 3

OW

Period

float

0-100

PdschBLERperMCS3_ Tot/PdschBLERperMC S3_Cnt*100

sum (PdschBLERperMCS3_Tot)/ sum (PdschBLERperMCS3_Cnt) *100

PdschBLERper MCS4

PDSCH BLER transmitted to MCS 4

OW

Period

float

0-100

PdschBLERperMCS4_ Tot/PdschBLERperMC S4_Cnt*100

sum (PdschBLERperMCS4_Tot)/ sum (PdschBLERperMCS4_Cnt) *100

PdschBLERper MCS5

PDSCH BLER transmitted to MCS 5

OW

Period

float

0-100

PdschBLERperMCS5_ Tot/PdschBLERperMC S5_Cnt*100

sum (PdschBLERperMCS5_Tot)/ sum (PdschBLERperMCS5_Cnt) *100

PdschBLERper MCS6

PDSCH BLER transmitted to MCS 6

OW

Period

float

0-100

PdschBLERperMCS6_ Tot/PdschBLERperMC S6_Cnt*100

sum (PdschBLERperMCS6_Tot)/ sum (PdschBLERperMCS6_Cnt) *100

PdschBLERper MCS7

PDSCH BLER transmitted to MCS 7

OW

Period

float

0-100

PdschBLERperMCS7_ Tot/PdschBLERperMC S7_Cnt*100

sum (PdschBLERperMCS7_Tot)/ sum (PdschBLERperMCS7_Cnt)* 100

SAMSUNG Electronics Co., Ltd.

page 283 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdschBLERper MCS8

Unit %

Description PDSCH BLER transmitted to MCS 8

Visible Y

Counter Type OW

Trigger Type Period

Data Type float

Min/Max 0-100

Granularity Formula PdschBLERperMCS8_ Tot/PdschBLERperMC S8_Cnt*100

Hourly, Daily, Monthly Formula sum (PdschBLERperMCS8_Tot)/ sum (PdschBLERperMCS8_Cnt)* 100

PdschBLERper MCS9

PDSCH BLER transmitted to MCS 9

OW

Period

float

0-100

PdschBLERperMCS9_ Tot/PdschBLERperMC S9_Cnt*100

sum (PdschBLERperMCS9_Tot)/ sum (PdschBLERperMCS9_Cnt) *100

PdschBLERperM CS10

PDSCH BLER transmitted to MCS 10

OW

Period

float

0-100

PdschBLERperMCS10 _Tot/PdschBLERperM CS10_Cnt*100

sum (PdschBLERperMCS10_Tot)/ sum (PdschBLERperMCS10_Cnt) *100

PdschBLERperM CS11

PDSCH BLER transmitted to MCS 11

OW

Period

float

0-100

PdschBLERperMCS11 _Tot/PdschBLERperM CS11_Cnt*100

sum (PdschBLERperMCS11_Tot)/ sum (PdschBLERperMCS11_Cnt) *100

PdschBLERperM CS12

PDSCH BLER transmitted to MCS 12

OW

Period

float

0-100

PdschBLERperMCS12 _Tot/PdschBLERperM CS12_Cnt*100

sum (PdschBLERperMCS12_Tot)/ sum (PdschBLERperMCS12_Cnt) *100

PdschBLERperM

PDSCH BLER

OW

Period

float

0-100

PdschBLERperMCS13

sum

SAMSUNG Electronics Co., Ltd.

page 284 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name CS13

Unit

Description transmitted to MCS 13

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula _Tot/PdschBLERperM CS13_Cnt*100

Hourly, Daily, Monthly Formula (PdschBLERperMCS13_Tot)/ sum (PdschBLERperMCS13_Cnt) *100

PdschBLERperM CS14

PDSCH BLER transmitted to MCS 14

OW

Period

float

0-100

PdschBLERperMCS14 _Tot/PdschBLERperM CS14_Cnt*100

sum (PdschBLERperMCS14_Tot)/ sum (PdschBLERperMCS14_Cnt) *100

PdschBLERperM CS15

PDSCH BLER transmitted to MCS 15

OW

Period

float

0-100

PdschBLERperMCS15 _Tot/PdschBLERperM CS15_Cnt*100

sum (PdschBLERperMCS15_Tot)/ sum (PdschBLERperMCS15_Cnt) *100

PdschBLERperM CS16

PDSCH BLER transmitted to MCS 16

OW

Period

float

0-100

PdschBLERperMCS16 _Tot/PdschBLERperM CS16_Cnt*100

sum (PdschBLERperMCS16_Tot)/ sum (PdschBLERperMCS16_Cnt) *100

PdschBLERperM CS17

PDSCH BLER transmitted to MCS 17

OW

Period

float

0-100

PdschBLERperMCS17 _Tot/PdschBLERperM CS17_Cnt*100

sum (PdschBLERperMCS17_Tot)/ sum (PdschBLERperMCS17_Cnt) *100

PdschBLERperM CS18

PDSCH BLER transmitted to MCS

OW

Period

float

0-100

PdschBLERperMCS18 _Tot/PdschBLERperM

sum (PdschBLERperMCS18_Tot)/

SAMSUNG Electronics Co., Ltd.

page 285 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit 18

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula CS18_Cnt*100

Hourly, Daily, Monthly Formula sum (PdschBLERperMCS18_Cnt) *100

PdschBLERperM CS19

PDSCH BLER transmitted to MCS 19

OW

Period

float

0-100

PdschBLERperMCS19 _Tot/PdschBLERperM CS19_Cnt*100

sum (PdschBLERperMCS19_Tot)/ sum (PdschBLERperMCS19_Cnt) *100

PdschBLERperM CS20

PDSCH BLER transmitted to MCS 20

OW

Period

float

0-100

PdschBLERperMCS20 _Tot/PdschBLERperM CS20_Cnt*100

sum (PdschBLERperMCS20_Tot)/ sum (PdschBLERperMCS20_Cnt) *100

PdschBLERperM CS21

PDSCH BLER transmitted to MCS 21

OW

Period

float

0-100

PdschBLERperMCS21 _Tot/PdschBLERperM CS21_Cnt*100

sum (PdschBLERperMCS21_Tot)/ sum (PdschBLERperMCS21_Cnt) *100

PdschBLERperM CS22

PDSCH BLER transmitted to MCS 22

OW

Period

float

0-100

PdschBLERperMCS22 _Tot/PdschBLERperM CS22_Cnt*100

sum (PdschBLERperMCS22_Tot)/ sum (PdschBLERperMCS22_Cnt) *100

PdschBLERperM CS23

PDSCH BLER transmitted to MCS 23

OW

Period

float

0-100

PdschBLERperMCS23 _Tot/PdschBLERperM CS23_Cnt*100

sum (PdschBLERperMCS23_Tot)/ sum

SAMSUNG Electronics Co., Ltd.

page 286 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula (PdschBLERperMCS23_Cnt) *100

PdschBLERperM CS24

PDSCH BLER transmitted to MCS 24

OW

Period

float

0-100

PdschBLERperMCS24 _Tot/PdschBLERperM CS24_Cnt*100

sum (PdschBLERperMCS24_Tot)/ sum (PdschBLERperMCS24_Cnt) *100

PdschBLERperM CS25

PDSCH BLER transmitted to MCS 25

OW

Period

float

0-100

PdschBLERperMCS25 _Tot/PdschBLERperM CS25_Cnt*100

sum (PdschBLERperMCS25_Tot)/ sum (PdschBLERperMCS25_Cnt) *100

PdschBLERperM CS26

PDSCH BLER transmitted to MCS 26

OW

Period

float

0-100

PdschBLERperMCS26 _Tot/PdschBLERperM CS26_Cnt*100

sum (PdschBLERperMCS26_Tot)/ sum (PdschBLERperMCS26_Cnt) *100

PdschBLERperM CS27

PDSCH BLER transmitted to MCS 27

OW

Period

float

0-100

PdschBLERperMCS27 _Tot/PdschBLERperM CS27_Cnt*100

sum (PdschBLERperMCS27_Tot)/ sum (PdschBLERperMCS27_Cnt) *100

PdschBLERperM CS28

PDSCH BLER transmitted to MCS 28

OW

Period

float

0-100

PdschBLERperMCS28 _Tot/PdschBLERperM CS28_Cnt*100

sum (PdschBLERperMCS28_Tot)/ sum (PdschBLERperMCS28_Cnt)

SAMSUNG Electronics Co., Ltd.

page 287 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula *100

PdschBLERperM CS29

PDSCH BLER transmitted to MCS 29

OW

Period

float

0-100

PdschBLERperMCS29 _Tot/PdschBLERperM CS29_Cnt*100

sum (PdschBLERperMCS29_Tot)/ sum (PdschBLERperMCS29_Cnt) *100

PdschBLERperM CS30

PDSCH BLER transmitted to MCS 30

OW

Period

float

0-100

PdschBLERperMCS30 _Tot/PdschBLERperM CS30_Cnt*100

sum (PdschBLERperMCS30_Tot)/ sum (PdschBLERperMCS30_Cnt) *100

PdschBLERperM CS31

PDSCH BLER transmitted to MCS 31

OW

Period

float

0-100

PdschBLERperMCS31 _Tot/PdschBLERperM CS31_Cnt*100

sum (PdschBLERperMCS31_Tot)/ sum (PdschBLERperMCS31_Cnt) *100

PdschBLERper MCS0_Tot

count

PDSCH Error count transmitted to MCS 0 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS1_Tot

count

PDSCH Error count transmitted to MCS 1 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS2_Tot

count

PDSCH Error count transmitted to MCS 2 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper

count

PDSCH Error count

CC

5s

float

0~3.4*10^

SAMSUNG Electronics Co., Ltd.

page 288 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MCS3_Tot

Unit

Description transmitted to MCS 3 (all errors)

Visible

Counter Type

Trigger Type

Data Type

Min/Max 38

Granularity Formula

Hourly, Daily, Monthly Formula

PdschBLERper MCS4_Tot

count

PDSCH Error count transmitted to MCS 4 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS5_Tot

count

PDSCH Error count transmitted to MCS 5 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS6_Tot

count

PDSCH Error count transmitted to MCS 6 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS7_Tot

count

PDSCH Error count transmitted to MCS 7 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS8_Tot

count

PDSCH Error count transmitted to MCS 8 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS9_Tot

count

PDSCH Error count transmitted to MCS 9 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS10_Tot

count

PDSCH Error count transmitted to MCS 10 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS11_Tot

count

PDSCH Error count transmitted to MCS

CC

5s

float

0~3.4*10^ 38

SAMSUNG Electronics Co., Ltd.

page 289 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description 11 (all errors)

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

PdschBLERper MCS12_Tot

count

PDSCH Error count transmitted to MCS 12 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS13_Tot

count

PDSCH Error count transmitted to MCS 13 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS14_Tot

count

PDSCH Error count transmitted to MCS 14 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS15_Tot

count

PDSCH Error count transmitted to MCS 15 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS16_Tot

count

PDSCH Error count transmitted to MCS 16 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS17_Tot

count

PDSCH Error count transmitted to MCS 17 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS18_Tot

count

PDSCH Error count transmitted to MCS 18 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS19_Tot

count

PDSCH Error count transmitted to MCS 19 (all errors)

CC

5s

float

0~3.4*10^ 38

SAMSUNG Electronics Co., Ltd.

page 290 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdschBLERper MCS20_Tot

Unit count

Description PDSCH Error count transmitted to MCS 20 (all errors)

Visible Y

Counter Type CC

Trigger Type 5s

Data Type float

Min/Max 0~3.4*10^ 38 -

Granularity Formula -

Hourly, Daily, Monthly Formula

PdschBLERper MCS21_Tot

count

PDSCH Error count transmitted to MCS 21 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS22_Tot

count

PDSCH Error count transmitted to MCS 22 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS23_Tot

count

PDSCH Error count transmitted to MCS 23 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS24_Tot

count

PDSCH Error count transmitted to MCS 24 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS25_Tot

count

PDSCH Error count transmitted to MCS 25 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS26_Tot

count

PDSCH Error count transmitted to MCS 26 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS27_Tot

count

PDSCH Error count transmitted to MCS 27 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper

count

PDSCH Error count

CC

5s

float

0~3.4*10^

SAMSUNG Electronics Co., Ltd.

page 291 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MCS28_Tot

Unit

Description transmitted to MCS 28 (all errors)

Visible

Counter Type

Trigger Type

Data Type

Min/Max 38

Granularity Formula

Hourly, Daily, Monthly Formula

PdschBLERper MCS29_Tot

count

PDSCH Error count transmitted to MCS 29 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS30_Tot

count

PDSCH Error count transmitted to MCS 30 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS31_Tot

count

PDSCH Error count transmitted to MCS 31 (all errors)

CC

5s

float

0~3.4*10^ 38

PdschBLERper MCS0_Cnt PdschBLERper MCS1_Cnt PdschBLERper MCS2_Cnt PdschBLERper MCS3_Cnt PdschBLERper MCS4_Cnt PdschBLERper MCS5_Cnt PdschBLERper MCS6_Cnt

count

Total PDSCH count transmitted to MCS 0

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 1

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 2

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 3

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 4

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 5

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 6

CC

5s

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 292 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdschBLERper MCS7_Cnt PdschBLERper MCS8_Cnt PdschBLERper MCS9_Cnt PdschBLERper MCS10_Cnt

Unit count

Description Total PDSCH count transmitted to MCS 7

Visible Y

Counter Type CC

Trigger Type 5s

Data Type int

Min/Max 0~214748 3647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

count

Total PDSCH count transmitted to MCS 8

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 9

CC

5s

int

0~214748 3647

count

Total PDSCH count transmitted to MCS 10

CC

5s

int

0~214748 3647

PdschBLERper MCS11_Cnt

count

Total PDSCH count transmitted to MCS 11

CC

5s

int

0~214748 3647

PdschBLERper MCS12_Cnt

count

Total PDSCH count transmitted to MCS 12

CC

5s

int

0~214748 3647

PdschBLERper MCS13_Cnt

count

Total PDSCH count transmitted to MCS 13

CC

5s

int

0~214748 3647

PdschBLERper MCS14_Cnt

count

Total PDSCH count transmitted to MCS 14

CC

5s

int

0~214748 3647

PdschBLERper MCS15_Cnt

count

Total PDSCH count transmitted to MCS 15

CC

5s

int

0~214748 3647

PdschBLERper

count

Total PDSCH count

CC

5s

int

0~214748

SAMSUNG Electronics Co., Ltd.

page 293 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MCS16_Cnt

Unit

Description transmitted to MCS 16

Visible

Counter Type

Trigger Type

Data Type

Min/Max 3647

Granularity Formula

Hourly, Daily, Monthly Formula

PdschBLERper MCS17_Cnt

count

Total PDSCH count transmitted to MCS 17

CC

5s

int

0~214748 3647

PdschBLERper MCS18_Cnt

count

Total PDSCH count transmitted to MCS 18

CC

5s

int

0~214748 3647

PdschBLERper MCS19_Cnt

count

Total PDSCH count transmitted to MCS 19

CC

5s

int

0~214748 3647

PdschBLERper MCS20_Cnt

count

Total PDSCH count transmitted to MCS 20

CC

5s

int

0~214748 3647

PdschBLERper MCS21_Cnt

count

Total PDSCH count transmitted to MCS 21

CC

5s

int

0~214748 3647

PdschBLERper MCS22_Cnt

count

Total PDSCH count transmitted to MCS 22

CC

5s

int

0~214748 3647

PdschBLERper MCS23_Cnt

count

Total PDSCH count transmitted to MCS 23

CC

5s

int

0~214748 3647

PdschBLERper MCS24_Cnt

count

Total PDSCH count transmitted to MCS

CC

5s

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 294 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit 24

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

PdschBLERper MCS25_Cnt

count

Total PDSCH count transmitted to MCS 25

CC

5s

int

0~214748 3647

PdschBLERper MCS26_Cnt

count

Total PDSCH count transmitted to MCS 26

CC

5s

int

0~214748 3647

PdschBLERper MCS27_Cnt

count

Total PDSCH count transmitted to MCS 27

CC

5s

int

0~214748 3647

PdschBLERper MCS28_Cnt

count

Total PDSCH count transmitted to MCS 28

CC

5s

int

0~214748 3647

PdschBLERper MCS29_Cnt

count

Total PDSCH count transmitted to MCS 29

CC

5s

int

0~214748 3647

PdschBLERper MCS30_Cnt

count

Total PDSCH count transmitted to MCS 30

CC

5s

int

0~214748 3647

PdschBLERper MCS31_Cnt

count

Total PDSCH count transmitted to MCS 31

CC

5s

int

0~214748 3647

PuschBLERper MCS0

PUSCH BLER received to MCS 0

OW

Period

float

0-100

PuschBLERperMCS0_ Tot/PuschBLERperMC S0_Cnt*100

sum (PuschBLERperMCS0_Tot)/ sum

SAMSUNG Electronics Co., Ltd.

page 295 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula (PuschBLERperMCS0_Cnt) *100

PuschBLERper MCS1

PUSCH BLER received to MCS 1

OW

Period

float

0-100

PuschBLERperMCS1_ Tot/PuschBLERperMC S1_Cnt*100

sum (PuschBLERperMCS1_Tot)/ sum (PuschBLERperMCS1_Cnt) *100

PuschBLERper MCS2

PUSCH BLER received to MCS 2

OW

Period

float

0-100

PuschBLERperMCS2_ Tot/PuschBLERperMC S2_Cnt*100

sum (PuschBLERperMCS2_Tot)/ sum (PuschBLERperMCS2_Cnt) *100

PuschBLERper MCS3

PUSCH BLER received to MCS 3

OW

Period

float

0-100

PuschBLERperMCS3_ Tot/PuschBLERperMC S3_Cnt*100

sum (PuschBLERperMCS3_Tot)/ sum (PuschBLERperMCS3_Cnt) *100

PuschBLERper MCS4

PUSCH BLER received to MCS 4

OW

Period

float

0-100

PuschBLERperMCS4_ Tot/PuschBLERperMC S4_Cnt*100

sum (PuschBLERperMCS4_Tot)/ sum (PuschBLERperMCS4_Cnt) *100

PuschBLERper MCS5

PUSCH BLER received to MCS 5

OW

Period

float

0-100

PuschBLERperMCS5_ Tot/PuschBLERperMC S5_Cnt*100

sum (PuschBLERperMCS5_Tot)/ sum (PuschBLERperMCS5_Cnt)

SAMSUNG Electronics Co., Ltd.

page 296 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula *100

PuschBLERper MCS6

PUSCH BLER received to MCS 6

OW

Period

float

0-100

PuschBLERperMCS6_ Tot/PuschBLERperMC S6_Cnt*100

sum (PuschBLERperMCS6_Tot)/ sum (PuschBLERperMCS6_Cnt) *100

PuschBLERper MCS7

PUSCH BLER received to MCS 7

OW

Period

float

0-100

PuschBLERperMCS7_ Tot/PuschBLERperMC S7_Cnt*100

sum (PuschBLERperMCS7_Tot)/ sum (PuschBLERperMCS7_Cnt) *100

PuschBLERper MCS8

PUSCH BLER received to MCS 8

OW

Period

float

0-100

PuschBLERperMCS8_ Tot/PuschBLERperMC S8_Cnt*100

sum (PuschBLERperMCS8_Tot)/ sum (PuschBLERperMCS8_Cnt) *100

PuschBLERper MCS9

PUSCH BLER received to MCS 9

OW

Period

float

0-100

PuschBLERperMCS9_ Tot/PuschBLERperMC S9_Cnt*100

sum (PuschBLERperMCS9_Tot)/ sum (PuschBLERperMCS9_Cnt) *100

PuschBLERperM CS10

PUSCH BLER received to MCS 10

OW

Period

float

0-100

PuschBLERperMCS10 _Tot/PuschBLERperM CS10_Cnt*100

sum (PuschBLERperMCS10_Tot)/ sum (PuschBLERperMCS10_Cnt) *100

SAMSUNG Electronics Co., Ltd.

page 297 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PuschBLERperM CS11

Unit %

Description PUSCH BLER received to MCS 11

Visible Y

Counter Type OW

Trigger Type Period

Data Type float

Min/Max 0-100

Granularity Formula PuschBLERperMCS11 _Tot/PuschBLERperM CS11_Cnt*100

Hourly, Daily, Monthly Formula sum (PuschBLERperMCS11_Tot)/ sum (PuschBLERperMCS11_Cnt) *100

PuschBLERperM CS12

PUSCH BLER received to MCS 12

OW

Period

float

0-100

PuschBLERperMCS12 _Tot/PuschBLERperM CS12_Cnt*100

sum (PuschBLERperMCS12_Tot)/ sum (PuschBLERperMCS12_Cnt) *100

PuschBLERperM CS13

PUSCH BLER received to MCS 13

OW

Period

float

0-100

PuschBLERperMCS13 _Tot/PuschBLERperM CS13_Cnt*100

sum (PuschBLERperMCS13_Tot)/ sum (PuschBLERperMCS13_Cnt) *100

PuschBLERperM CS14

PUSCH BLER received to MCS 14

OW

Period

float

0-100

PuschBLERperMCS14 _Tot/PuschBLERperM CS14_Cnt*100

sum (PuschBLERperMCS14_Tot)/ sum (PuschBLERperMCS14_Cnt) *100

PuschBLERperM CS15

PUSCH BLER received to MCS 15

OW

Period

float

0-100

PuschBLERperMCS15 _Tot/PuschBLERperM CS15_Cnt*100

sum (PuschBLERperMCS15_Tot)/ sum (PuschBLERperMCS15_Cnt) *100

PuschBLERperM

PUSCH BLER

OW

Period

float

0-100

PuschBLERperMCS16

sum

SAMSUNG Electronics Co., Ltd.

page 298 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name CS16

Unit

Description received to MCS 16

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula _Tot/PuschBLERperM CS16_Cnt*100

Hourly, Daily, Monthly Formula (PuschBLERperMCS16_Tot)/ sum (PuschBLERperMCS16_Cnt) *100

PuschBLERperM CS17

PUSCH BLER received to MCS 17

OW

Period

float

0-100

PuschBLERperMCS17 _Tot/PuschBLERperM CS17_Cnt*100

sum (PuschBLERperMCS17_Tot)/ sum (PuschBLERperMCS17_Cnt) *100

PuschBLERperM CS18

PUSCH BLER received to MCS 18

OW

Period

float

0-100

PuschBLERperMCS18 _Tot/PuschBLERperM CS18_Cnt*100

sum (PuschBLERperMCS18_Tot)/ sum (PuschBLERperMCS18_Cnt) *100

PuschBLERperM CS19

PUSCH BLER received to MCS 19

OW

Period

float

0-100

PuschBLERperMCS19 _Tot/PuschBLERperM CS19_Cnt*100

sum (PuschBLERperMCS19_Tot)/ sum (PuschBLERperMCS19_Cnt) *100

PuschBLERperM CS20

PUSCH BLER received to MCS 20

OW

Period

float

0-100

PuschBLERperMCS20 _Tot/PuschBLERperM CS20_Cnt*100

sum (PuschBLERperMCS20_Tot)/ sum (PuschBLERperMCS20_Cnt) *100

PuschBLERperM CS21

PUSCH BLER received to MCS 21

OW

Period

float

0-100

PuschBLERperMCS21 _Tot/PuschBLERperM

sum (PuschBLERperMCS21_Tot)/

SAMSUNG Electronics Co., Ltd.

page 299 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula CS21_Cnt*100

Hourly, Daily, Monthly Formula sum (PuschBLERperMCS21_Cnt) *100

PuschBLERperM CS22

PUSCH BLER received to MCS 22

OW

Period

float

0-100

PuschBLERperMCS22 _Tot/PuschBLERperM CS22_Cnt*100

sum (PuschBLERperMCS22_Tot)/ sum (PuschBLERperMCS22_Cnt) *100

PuschBLERperM CS23

PUSCH BLER received to MCS 23

OW

Period

float

0-100

PuschBLERperMCS23 _Tot/PuschBLERperM CS23_Cnt*100

sum (PuschBLERperMCS23_Tot)/ sum (PuschBLERperMCS23_Cnt) *100

PuschBLERperM CS24

PUSCH BLER received to MCS 24

OW

Period

float

0-100

PuschBLERperMCS24 _Tot/PuschBLERperM CS24_Cnt*100

sum (PuschBLERperMCS24_Tot)/ sum (PuschBLERperMCS24_Cnt) *100

PuschBLERperM CS25

PUSCH BLER received to MCS 25

OW

Period

float

0-100

PuschBLERperMCS25 _Tot/PuschBLERperM CS25_Cnt*100

sum (PuschBLERperMCS25_Tot)/ sum (PuschBLERperMCS25_Cnt) *100

PuschBLERperM CS26

PUSCH BLER received to MCS 26

OW

Period

float

0-100

PuschBLERperMCS26 _Tot/PuschBLERperM CS26_Cnt*100

sum (PuschBLERperMCS26_Tot)/ sum

SAMSUNG Electronics Co., Ltd.

page 300 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula (PuschBLERperMCS26_Cnt) *100

PuschBLERperM CS27

PUSCH BLER received to MCS 27

OW

Period

float

0-100

PuschBLERperMCS27 _Tot/PuschBLERperM CS27_Cnt*100

sum (PuschBLERperMCS27_Tot)/ sum (PuschBLERperMCS27_Cnt) *100

PuschBLERperM CS28

PUSCH BLER received to MCS 28

OW

Period

float

0-100

PuschBLERperMCS28 _Tot/PuschBLERperM CS28_Cnt*100

sum (PuschBLERperMCS28_Tot)/ sum (PuschBLERperMCS28_Cnt) *100

PuschBLERperM CS29

PUSCH BLER received to MCS 29

OW

Period

float

0-100

PuschBLERperMCS29 _Tot/PuschBLERperM CS29_Cnt*100

sum (PuschBLERperMCS29_Tot)/ sum (PuschBLERperMCS29_Cnt) *100

PuschBLERperM CS30

PUSCH BLER received to MCS 30

OW

Period

float

0-100

PuschBLERperMCS30 _Tot/PuschBLERperM CS30_Cnt*100

sum (PuschBLERperMCS30_Tot)/ sum (PuschBLERperMCS30_Cnt) *100

PuschBLERperM CS31

PUSCH BLER received to MCS 31

OW

Period

float

0-100

PuschBLERperMCS31 _Tot/PuschBLERperM CS31_Cnt*100

sum (PuschBLERperMCS31_Tot)/ sum (PuschBLERperMCS31_Cnt)

SAMSUNG Electronics Co., Ltd.

page 301 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula *100

PuschBLERper MCS0_Tot

count

PUSCH Error count transmitted to MCS 0 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS1_Tot

count

PUSCH Error count transmitted to MCS 1 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS2_Tot

count

PUSCH Error count transmitted to MCS 2 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS3_Tot

count

PUSCH Error count transmitted to MCS 3 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS4_Tot

count

PUSCH Error count transmitted to MCS 4 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS5_Tot

count

PUSCH Error count transmitted to MCS 5 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS6_Tot

count

PUSCH Error count transmitted to MCS 6 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS7_Tot

count

PUSCH Error count transmitted to MCS 7 (all errors)

CC

5s

float

0~3.4*10^ 38

SAMSUNG Electronics Co., Ltd.

page 302 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PuschBLERper MCS8_Tot

Unit count

Description PUSCH Error count transmitted to MCS 8 (all errors)

Visible -

Counter Type CC

Trigger Type 5s

Data Type float

Min/Max 0~3.4*10^ 38 -

Granularity Formula -

Hourly, Daily, Monthly Formula

PuschBLERper MCS9_Tot

count

PUSCH Error count transmitted to MCS 9 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS10_Tot

count

PUSCH Error count transmitted to MCS 10 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS11_Tot

count

PUSCH Error count transmitted to MCS 11 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS12_Tot

count

PUSCH Error count transmitted to MCS 12 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS13_Tot

count

PUSCH Error count transmitted to MCS 13 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS14_Tot

count

PUSCH Error count transmitted to MCS 14 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS15_Tot

count

PUSCH Error count transmitted to MCS 15 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper

count

PUSCH Error count

CC

5s

float

0~3.4*10^

SAMSUNG Electronics Co., Ltd.

page 303 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MCS16_Tot

Unit

Description transmitted to MCS 16 (all errors)

Visible

Counter Type

Trigger Type

Data Type

Min/Max 38

Granularity Formula

Hourly, Daily, Monthly Formula

PuschBLERper MCS17_Tot

count

PUSCH Error count transmitted to MCS 17 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS18_Tot

count

PUSCH Error count transmitted to MCS 18 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS19_Tot

count

PUSCH Error count transmitted to MCS 19 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS20_Tot

count

PUSCH Error count transmitted to MCS 20 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS21_Tot

count

PUSCH Error count transmitted to MCS 21 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS22_Tot

count

PUSCH Error count transmitted to MCS 22 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS23_Tot

count

PUSCH Error count transmitted to MCS 23 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS24_Tot

count

PUSCH Error count transmitted to MCS

CC

5s

float

0~3.4*10^ 38

SAMSUNG Electronics Co., Ltd.

page 304 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description 24 (all errors)

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

PuschBLERper MCS25_Tot

count

PUSCH Error count transmitted to MCS 25 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS26_Tot

count

PUSCH Error count transmitted to MCS 26 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS27_Tot

count

PUSCH Error count transmitted to MCS 27 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS28_Tot

count

PUSCH Error count transmitted to MCS 28 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS29_Tot

count

PUSCH Error count transmitted to MCS 29 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS30_Tot

count

PUSCH Error count transmitted to MCS 30 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS31_Tot

count

PUSCH Error count transmitted to MCS 31 (all errors)

CC

5s

float

0~3.4*10^ 38

PuschBLERper MCS0_Cnt PuschBLERper

count

Total PUSCH count transmitted to MCS 0

CC

5s

int

0~214748 3647

count

Total PUSCH count

CC

5s

int

0~214748

SAMSUNG Electronics Co., Ltd.

page 305 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MCS1_Cnt PuschBLERper MCS2_Cnt PuschBLERper MCS3_Cnt PuschBLERper MCS4_Cnt PuschBLERper MCS5_Cnt PuschBLERper MCS6_Cnt PuschBLERper MCS7_Cnt PuschBLERper MCS8_Cnt PuschBLERper MCS9_Cnt PuschBLERper MCS10_Cnt

Unit

Description transmitted to MCS 1

Visible

Counter Type

Trigger Type

Data Type

Min/Max 3647

Granularity Formula

Hourly, Daily, Monthly Formula

count

Total PUSCH count transmitted to MCS 2

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 3

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 4

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 5

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 6

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 7

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 8

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 9

CC

5s

int

0~214748 3647

count

Total PUSCH count transmitted to MCS 10

CC

5s

int

0~214748 3647

PuschBLERper MCS11_Cnt

count

Total PUSCH count transmitted to MCS 11

CC

5s

int

0~214748 3647

PuschBLERper MCS12_Cnt

count

Total PUSCH count transmitted to MCS

CC

5s

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 306 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit 12

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

PuschBLERper MCS13_Cnt

count

Total PUSCH count transmitted to MCS 13

CC

5s

int

0~214748 3647

PuschBLERper MCS14_Cnt

count

Total PUSCH count transmitted to MCS 14

CC

5s

int

0~214748 3647

PuschBLERper MCS15_Cnt

count

Total PUSCH count transmitted to MCS 15

CC

5s

int

0~214748 3647

PuschBLERper MCS16_Cnt

count

Total PUSCH count transmitted to MCS 16

CC

5s

int

0~214748 3647

PuschBLERper MCS17_Cnt

count

Total PUSCH count transmitted to MCS 17

CC

5s

int

0~214748 3647

PuschBLERper MCS18_Cnt

count

Total PUSCH count transmitted to MCS 18

CC

5s

int

0~214748 3647

PuschBLERper MCS19_Cnt

count

Total PUSCH count transmitted to MCS 19

CC

5s

int

0~214748 3647

PuschBLERper MCS20_Cnt

count

Total PUSCH count transmitted to MCS 20

CC

5s

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 307 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PuschBLERper MCS21_Cnt

Unit count

Description Total PUSCH count transmitted to MCS 21

Visible -

Counter Type CC

Trigger Type 5s

Data Type int

Min/Max 0~214748 3647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

PuschBLERper MCS22_Cnt

count

Total PUSCH count transmitted to MCS 22

CC

5s

int

0~214748 3647

PuschBLERper MCS23_Cnt

count

Total PUSCH count transmitted to MCS 23

CC

5s

int

0~214748 3647

PuschBLERper MCS24_Cnt

count

Total PUSCH count transmitted to MCS 24

CC

5s

int

0~214748 3647

PuschBLERper MCS25_Cnt

count

Total PUSCH count transmitted to MCS 25

CC

5s

int

0~214748 3647

PuschBLERper MCS26_Cnt

count

Total PUSCH count transmitted to MCS 26

CC

5s

int

0~214748 3647

PuschBLERper MCS27_Cnt

count

Total PUSCH count transmitted to MCS 27

CC

5s

int

0~214748 3647

PuschBLERper MCS28_Cnt

count

Total PUSCH count transmitted to MCS 28

CC

5s

int

0~214748 3647

PuschBLERper

count

Total PUSCH count

CC

5s

int

0~214748

SAMSUNG Electronics Co., Ltd.

page 308 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MCS29_Cnt

Unit

Description transmitted to MCS 29

Visible

Counter Type

Trigger Type

Data Type

Min/Max 3647

Granularity Formula

Hourly, Daily, Monthly Formula

PuschBLERper MCS30_Cnt

count

Total PUSCH count transmitted to MCS 30

CC

5s

int

0~214748 3647

PuschBLERper MCS31_Cnt

count

Total PUSCH count transmitted to MCS 31

CC

5s

int

0~214748 3647

UlReceivedMCS 0

count

The number of times PUSCH of MCS 0 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 1

count

The number of times PUSCH of MCS 1 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 2

count

The number of times PUSCH of MCS 2 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 3

count

The number of times PUSCH of MCS 3 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 4

count

The number of times PUSCH of MCS 4 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 5

count

The number of times PUSCH of MCS 5 is

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 309 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description received

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

UlReceivedMCS 6

count

The number of times PUSCH of MCS 6 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 7

count

The number of times PUSCH of MCS 7 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 8

count

The number of times PUSCH of MCS 8 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 9

count

The number of times PUSCH of MCS 9 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 10

count

The number of times PUSCH of MCS 10 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 11

count

The number of times PUSCH of MCS 11 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 12

count

The number of times PUSCH of MCS 12 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 13

count

The number of times PUSCH of MCS 13 is received

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 310 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlReceivedMCS 14

Unit count

Description The number of times PUSCH of MCS 14 is received

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-214748 3647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

UlReceivedMCS 15

count

The number of times PUSCH of MCS 15 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 16

count

The number of times PUSCH of MCS 16 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 17

count

The number of times PUSCH of MCS 17 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 18

count

The number of times PUSCH of MCS 18 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 19

count

The number of times PUSCH of MCS 19 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 20

count

The number of times PUSCH of MCS 20 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 21

count

The number of times PUSCH of MCS 21 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS

count

The number of times

CC

5.12 s.

int

0-214748

SAMSUNG Electronics Co., Ltd.

page 311 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name 22

Unit

Description PUSCH of MCS 22 is received

Visible

Counter Type

Trigger Type

Data Type

Min/Max 3647

Granularity Formula

Hourly, Daily, Monthly Formula

UlReceivedMCS 23

count

The number of times PUSCH of MCS 23 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 24

count

The number of times PUSCH of MCS 24 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 25

count

The number of times PUSCH of MCS 25 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 26

count

The number of times PUSCH of MCS 26 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 27

count

The number of times PUSCH of MCS 27 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 28

count

The number of times PUSCH of MCS 28 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 29

count

The number of times PUSCH of MCS 29 is received

CC

5.12 s.

int

0-214748 3647

UlReceivedMCS 30

count

The number of times PUSCH of MCS 30 is

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 312 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description received

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

UlReceivedMCS 31

count

The number of times PUSCH of MCS 31 is received

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S0

count

The number of PRBs assigned to PDSCH MCS 0

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S1

count

The number of PRBs assigned to DSCH MCS 1

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S2

count

The number of PRBs assigned to DSCH MCS 2

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S3

count

The number of PRBs assigned to DSCH MCS 3

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S4

count

The number of PRBs assigned to DSCH MCS 4

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S5

count

The number of PRBs assigned to DSCH MCS 5

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S6

count

The number of PRBs assigned to DSCH MCS 6

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 313 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlSchedulerMC S7

Unit count

Description The number of PRBs assigned to DSCH MCS 7

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-214748 3647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

DlSchedulerMC S8

count

The number of PRBs assigned to DSCH MCS 8

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S9

count

The number of PRBs assigned to DSCH MCS 9

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S10

count

The number of PRBs assigned to DSCH MCS 10

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S11

count

The number of PRBs assigned to DSCH MCS 11

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S12

count

The number of PRBs assigned to DSCH MCS 12

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S13

count

The number of PRBs assigned to DSCH MCS 13

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S14

count

The number of PRBs assigned to PDSCH MCS 14

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC

count

The number of PRBs

CC

5.12 s.

int

0-214748

SAMSUNG Electronics Co., Ltd.

page 314 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S15

Unit

Description assigned to PDSCH MCS 15

Visible

Counter Type

Trigger Type

Data Type

Min/Max 3647

Granularity Formula

Hourly, Daily, Monthly Formula

DlSchedulerMC S16

count

The number of PRBs assigned to PDSCH MCS 16

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S17

count

The number of PRBs assigned to PDSCH MCS 17

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S18

count

The number of PRBs assigned to PDSCH MCS 18

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S19

count

The number of PRBs assigned to PDSCH MCS 19

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S20

count

The number of PRBs assigned to PDSCH MCS 20

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S21

count

The number of PRBs assigned to PDSCH MCS 21

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S22

count

The number of PRBs assigned to PDSCH MCS 22

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S23

count

The number of PRBs assigned to PDSCH

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 315 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description MCS 23

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

DlSchedulerMC S24

count

The number of PRBs assigned to PDSCH MCS 24

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S25

count

The number of PRBs assigned to PDSCH MCS 25

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S26

count

The number of PRBs assigned to PDSCH MCS 26

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S27

count

The number of PRBs assigned to PDSCH MCS 27

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S28

count

The number of PRBs assigned to PDSCH MCS 28

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S29

count

The number of PRBs assigned to PDSCH MCS 29

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S30

count

The number of PRBs assigned to PDSCH MCS 30

CC

5.12 s.

int

0-214748 3647

DlSchedulerMC S31

count

The number of PRBs assigned to PDSCH MCS 31

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 316 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlSchedulerMC S0

Unit count

Description The number of PRBs assigned to PUSCH MCS 0

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-214748 3647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

UlSchedulerMC S1

count

The number of PRBs assigned to PUSCH MCS 1

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S2

count

The number of PRBs assigned to PUSCH MCS 2

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S3

count

The number of PRBs assigned to PUSCH MCS 3

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S4

count

The number of PRBs assigned to PUSCH MCS 4

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S5

count

The number of PRBs assigned to PUSCH MCS 5

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S6

count

The number of PRBs assigned to PUSCH MCS 6

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S7

count

The number of PRBs assigned to PUSCH MCS 7

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC

count

The number of PRBs

CC

5.12 s.

int

0-214748

SAMSUNG Electronics Co., Ltd.

page 317 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S8

Unit

Description assigned to PUSCH MCS 8

Visible

Counter Type

Trigger Type

Data Type

Min/Max 3647

Granularity Formula

Hourly, Daily, Monthly Formula

UlSchedulerMC S9

count

The number of PRBs assigned to PUSCH MCS 9

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S10

count

The number of PRBs assigned to PUSCH MCS 10

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S11

count

The number of PRBs assigned to PUSCH MCS 11

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S12

count

The number of PRBs assigned to PUSCH MCS 12

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S13

count

The number of PRBs assigned to PUSCH MCS 13

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S14

count

The number of PRBs assigned to PUSCH MCS 14

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S15

count

The number of PRBs assigned to PUSCH MCS 15

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S16

count

The number of PRBs assigned to PUSCH

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 318 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description MCS 16

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

UlSchedulerMC S17

count

The number of PRBs assigned to PUSCH MCS 17

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S18

count

The number of PRBs assigned to PUSCH MCS 18

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S19

count

The number of PRBs assigned to PUSCH MCS 19

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S20

count

The number of PRBs assigned to PUSCH MCS 20

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S21

count

The number of PRBs assigned to PUSCH MCS 21

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S22

count

The number of PRBs assigned to PUSCH MCS 22

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S23

count

The number of PRBs assigned to PUSCH MCS 23

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S24

count

The number of PRBs assigned to PUSCH MCS 24

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 319 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlSchedulerMC S25

Unit count

Description The number of PRBs assigned to PUSCH MCS 25

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-214748 3647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

UlSchedulerMC S26

count

The number of PRBs assigned to PUSCH MCS 26

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S27

count

The number of PRBs assigned to PUSCH MCS 27

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S28

count

The number of PRBs assigned to PUSCH MCS 28

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S29

count

The number of PRBs assigned to PUSCH MCS 29

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S30

count

The number of PRBs assigned to PUSCH MCS 30

CC

5.12 s.

int

0-214748 3647

UlSchedulerMC S31

count

The number of PRBs assigned to PUSCH MCS 31

CC

5.12 s.

int

0-214748 3647

SAMSUNG Electronics Co., Ltd.

page 320 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19.3 DL MCS
This section provides statistics data for transmission counts per MCS/layer/Codeword for PDSCH. Index
Name cNum mcID DL Layer 0~2 0~0 1~4 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Layer (data stream count) 1: 1 stream 2: 2 streams 3: 3 streams 4: 4 streams Codeword 0~1 Codeword (Transport block count) 0: First transport block 1: Second transport block Description

Type
Name DlTransmittedMC S0 Unit count Description The number of times that MCS 0 PDSCH is transmitted per layer/ codeword DlTransmittedMC S1 count The number of times that MCS 1 PDSCH is transmitted per layer/ codeword Y CC 5.12 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 5.12 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 321 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlTransmittedMC S2

Unit count

Description The number of times that MCS 2 PDSCH is transmitted per layer/ codeword

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlTransmittedMC S3

count

The number of times that MCS 3 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S4

count

The number of times that MCS 4 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S5

count

The number of times that MCS 5 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S6

count

The number of times that MCS 6 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S7

count

The number of times that MCS 7 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S8

count

The number of times that MCS 8 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S9

count

The number of times that MCS 9 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC

count

The number of times that MCS 10

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 322 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S10

Unit

Description PDSCH is transmitted per layer/ codeword

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

DlTransmittedMC S11

count

The number of times that MCS 11 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S12

count

The number of times that MCS 12 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S13

count

The number of times that MCS 13 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S14

count

The number of times that MCS 14 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S15

count

The number of times that MCS 15 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S16

count

The number of times that MCS 16 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S17

count

The number of times that MCS 17 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S18

count

The number of times that MCS 18 PDSCH is transmitted per layer/

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 323 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit codeword

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

DlTransmittedMC S19

count

The number of times that MCS 19 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S20

count

The number of times that MCS 20 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S21

count

The number of times that MCS 21 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S22

count

The number of times that MCS 22 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S23

count

The number of times that MCS 23 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S24

count

The number of times that MCS 24 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S25

count

The number of times that MCS 25 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S26

count

The number of times that MCS 26 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 324 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlTransmittedMC S27

Unit count

Description The number of times that MCS 27 PDSCH is transmitted per layer/ codeword

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlTransmittedMC S28

count

The number of times that MCS 28 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S29

count

The number of times that MCS 29 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S30

count

The number of times that MCS 30 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

DlTransmittedMC S31

count

The number of times that MCS 31 PDSCH is transmitted per layer/ codeword

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 325 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19.4 DL LAYER
This section provides statistics for data transmission counts per layer for PDSCH. Index
Name cNum mcID DL Layer 0~2 0~0 1~4 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Layer (data stream count) 1: 1 stream 2: 2 streams 3: 3 streams 4: 4 streams Description

Type
Name DlTransmittedLayer Unit count Description Transmission counts per layer for PDSCH Visible Y Counter Type CC Trigger Type 5.12 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 326 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19.5 DL CQI
This section provides CQI report information per layer/codeword for the UE Index
Name cNum mcID DL Layer 0~2 0~0 1~4 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Layer (data stream count) 1: 1 stream 2: 2 streams 3: 3 streams 4: 4 streams Codeword 0~1 Codeword Description

Type
Name DlReceivedCQI0 Unit count Description The number of times that CQI 0 is received per layer/codeword DlReceivedCQI1 count The number of times that CQI 1 is received per layer/codeword DlReceivedCQI2 count The number of times that CQI 2 is received per layer/codeword DlReceivedCQI3 count The number of times that CQI 3 is received per layer/codeword Y CC 5.12 s. int Y CC 5.12 s. int Y CC 5.12 s. int Visible Y Counter Type CC Trigger Type 5.12 s. Data Type int Min/Max 0-21474 83647 0-21474 83647 0-21474 83647 0-21474 83647 Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 327 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlReceivedCQI4

Unit count

Description The number of times that CQI 4 is received per layer/codeword

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-21474 83647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

DlReceivedCQI5

count

The number of times that CQI 5 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI6

count

The number of times that CQI 6 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI7

count

The number of times that CQI 7 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI8

count

The number of times that CQI 8 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI9

count

The number of times that CQI 9 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI10

count

The number of times that CQI 10 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI11

count

The number of times that CQI 11 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI12

count

The number of times that CQI 12 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI13

count

The number of times that CQI 13 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI14

count

The number of times that CQI 14 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

DlReceivedCQI15

count

The number of times that CQI 15 is received per layer/codeword

CC

5.12 s.

int

0-21474 83647

SAMSUNG Electronics Co., Ltd.

page 328 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlReceivedCQIMin

Unit CQI

Description Minimum value of DlReceivedCQI

Visible Y

Counter Type OW

Trigger Type Period

Data Type int

Min/Max 0-15 -

Granularity Formula

Hourly, Daily, Monthly Formula min (DlReceivedCQIMin)

DlReceivedCQIMax

CQI

Maximum value of DlReceivedCQI

OW

Period

int

0-15

max (DlReceivedCQIMax)

DlReceivedCQIAvg

CQI

Average value of DlReceivedCQI

OW

Period

float

0-15

(0*DlReceivedC QI0+1*DlReceive dCQI1+2*DlRece ivedCQI2+3*DlR eceivedCQI3+4* DlReceivedCQI4 +5*DlReceivedC QI5+6*DlReceive dCQI6+7*DlRece ivedCQI7+8*DlR eceivedCQI8+9* DlReceivedCQI9 +10*DlReceived CQI10+11*DlRec eivedCQI11+12* DlReceivedCQI1 2+13*DlReceive dCQI13+14*DlR eceivedCQI14+1 5*DlReceivedCQ I15)/(DlReceived CQI0+DlReceive dCQI1+DlReceiv

(0*sum (DlReceivedCQI0)+1* sum (DlReceivedCQI1)+2* sum (DlReceivedCQI2)+3* sum (DlReceivedCQI3)+4* sum (DlReceivedCQI4)+5* sum (DlReceivedCQI5)+6* sum (DlReceivedCQI6)+7* sum (DlReceivedCQI7)+8* sum (DlReceivedCQI8)+9* sum (DlReceivedCQI9)+10 *sum (DlReceivedCQI10)+1 1*sum

SAMSUNG Electronics Co., Ltd.

page 329 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula edCQI2+DlRecei vedCQI3+DlRec eivedCQI4+DlRe ceivedCQI5+DlR eceivedCQI6+Dl ReceivedCQI7+ DlReceivedCQI8 +DlReceivedCQI 9+DlReceivedC QI10+DlReceive dCQI11+DlRecei vedCQI12+DlRe ceivedCQI13+Dl ReceivedCQI14+ DlReceivedCQI1 5)

Hourly, Daily, Monthly Formula (DlReceivedCQI11)+1 2*sum (DlReceivedCQI12)+1 3*sum (DlReceivedCQI13)+1 4*sum (DlReceivedCQI14)+1 5*sum (DlReceivedCQI15))/( sum (DlReceivedCQI0)+su m (DlReceivedCQI1)+su m (DlReceivedCQI2)+su m (DlReceivedCQI3)+su m (DlReceivedCQI4)+su m (DlReceivedCQI5)+su m (DlReceivedCQI6)+su m (DlReceivedCQI7)+su m (DlReceivedCQI8)+su

SAMSUNG Electronics Co., Ltd.

page 330 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula m

Hourly, Daily, Monthly Formula

(DlReceivedCQI9)+su m (DlReceivedCQI10)+s um (DlReceivedCQI11)+s um (DlReceivedCQI12)+s um (DlReceivedCQI13)+s um (DlReceivedCQI14)+s um (DlReceivedCQI15))

SAMSUNG Electronics Co., Ltd.

page 331 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19.6 DL PMI
This section provides UEs PMI report information. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name DlReceivedPMI0 Unit count Description The number of times that PMI 0 is received DlReceivedPMI1 count The number of times that PMI 1 is received DlReceivedPMI2 count The number of times that PMI 2 is received DlReceivedPMI3 count The number of times that PMI 3 is received DlReceivedPMI4 count The number of times that PMI 4 is received DlReceivedPMI5 count The number of times that PMI 5 is received DlReceivedPMI6 count The number of times that PMI 6 is received Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Visible Y Counter Type CC Trigger Type 5.12 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 332 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlReceivedPMI7

Unit count

Description The number of times that PMI 7 is received

Visible Y

Counter Type CC

Trigger Type 5.12 s.

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlReceivedPMI8

count

The number of times that PMI 8 is received

CC

5.12 s.

int

0-2147483647

DlReceivedPMI9

count

The number of times that PMI 9 is received

CC

5.12 s.

int

0-2147483647

DlReceivedPMI10

count

The number of times that PMI 10 is received

CC

5.12 s.

int

0-2147483647

DlReceivedPMI11

count

The number of times that PMI 11 is received

CC

5.12 s.

int

0-2147483647

DlReceivedPMI12

count

The number of times that PMI 12 is received

CC

5.12 s.

int

0-2147483647

DlReceivedPMI13

count

The number of times that PMI 13 is received

CC

5.12 s.

int

0-2147483647

DlReceivedPMI14

count

The number of times that PMI 14 is received

CC

5.12 s.

int

0-2147483647

DlReceivedPMI15

count

The number of times that PMI 15 is received

CC

5.12 s.

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 333 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19.7 DL RI
This section provides UEs RI report information. Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name DlReceive dRI0 DlReceive dRI1 DlReceive dRI2 DlReceive dRI3 DlReceive dRI4 DlReceive dRIAvg RI count count count count The number of times that RI 1 is received The number of times that RI 2 is received The number of times that RI 3 is received The number of times that RI 4 is received Average value of DlReceivedRI Y OW Period float 0-4 (0*DlReceived RI0+1*DlRecei vedRI1+2*DlR eceivedRI2+3* (0*sum (DlReceivedRI0)+1*sum (DlReceivedRI1)+2*sum (DlReceivedRI2)+3*sum Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Y CC 5.12 s. int 0-2147483647 Unit count reserved Description Visible Y Counter Type CC Trigger Type 5.12 s. Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 334 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula DlReceivedRI3 +4*DlReceived RI4)/(DlReceiv edRI0+DlRecei vedRI1+DlRec eivedRI2+DlRe ceivedRI3+DlR eceivedRI4)

Hourly, Daily, Monthly Formula (DlReceivedRI3)+4*sum (DlReceivedRI4))/(sum (DlReceivedRI0)+sum (DlReceivedRI1)+sum (DlReceivedRI2)+sum (DlReceivedRI3)+sum (DlReceivedRI4))

SAMSUNG Electronics Co., Ltd.

page 335 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

19.8 DL ACK/NACK/DTX Ratio


This section provides UEs ACK/NACK/DTX ratio information. Index
Name cNum mcID DL Layer 0~2 0~0 1~4 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Layer (data stream count) 1: 1 stream 2: 2 streams 3: 3 streams 4: 4 streams Codeword Status 0~1 0~2 Codeword 0: ACK, 1: NACK, 2: DTX Description

Type
Name DlreceivedAckNa ckDtxRatio Unit % Description ACK, NACK, DTX ratio Visible Y Counter Type SI Trigger Type 5.12 s. Data Type float Min/Max 0-100 Granularity Formula DlreceivedAckNackDtx RatioTot/DlreceivedAck NackDtxRatioCnt Hourly, Daily, Monthly Formula sum (DlreceivedAckNack DtxRatioTot)/sum (DlreceivedAckNack DtxRatioCnt) DlreceivedAckNa ckDtxRatioTot % Total ACK, NACK, and DTX ratios SI 5.12 s float 0~3.4*10^38 -

SAMSUNG Electronics Co., Ltd.

page 336 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlreceivedAckNa ckDtxRatioCnt

Unit count

Description Total ACK, NACK, and DTX ratio count

Visible -

Counter Type SI

Trigger Type 5.12 s

Data Type int

Min/Max 0~21474836 47 -

Granularity Formula -

Hourly, Daily, Monthly Formula

SAMSUNG Electronics Co., Ltd.

page 337 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

20 IOT
20.1 Uplink IOT Level
This section provides statistics for 9 IoT levels. The IoT dB value is divided into 10 levels for each PRB. The statistics levels are classified as follows. Level 0: 0 <= IoT < 2 dB Level 1: 2 <= IoT < 4 dB Level 9: 18 <= IoT (count all that are equal to or greater than 18 dB) Index
Name cNum LEVEL 0~2 0~9 Range Serving Cell Index IOT Level Description

Type
Name PRB0 PRB1 PRB2 PRB3 PRB4 Unit count count count count count Description IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB Visible Y Y Y Y Y Counter Type CC CC CC CC CC Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. Data Type int int int int int Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 338 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PRB5 PRB6 PRB7 PRB8 PRB9 PRB10 PRB11 PRB12 PRB13 PRB14 PRB15 PRB16 PRB17 PRB18 PRB19 PRB20 PRB21 PRB22 PRB23 PRB24 PRB25 PRB26

Unit count count count count count count count count count count count count count count count count count count count count count count

Description IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 339 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PRB27 PRB28 PRB29 PRB30 PRB31 PRB32 PRB33 PRB34 PRB35 PRB36 PRB37 PRB38 PRB39 PRB40 PRB41 PRB42 PRB43 PRB44 PRB45 PRB46 PRB47 PRB48

Unit count count count count count count count count count count count count count count count count count count count count count count

Description IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 340 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PRB49 PRB50 PRB51 PRB52 PRB53 PRB54 PRB55 PRB56 PRB57 PRB58 PRB59 PRB60 PRB61 PRB62 PRB63 PRB64 PRB65 PRB66 PRB67 PRB68 PRB69 PRB70

Unit count count count count count count count count count count count count count count count count count count count count count count

Description IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 341 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PRB71 PRB72 PRB73 PRB74 PRB75 PRB76 PRB77 PRB78 PRB79 PRB80 PRB81 PRB82 PRB83 PRB84 PRB85 PRB86 PRB87 PRB88 PRB89 PRB90 PRB91 PRB92

Unit count count count count count count count count count count count count count count count count count count count count count count

Description IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB

Visible Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int int int int int int int int int int int int int int int int

Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 342 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PRB93 PRB94 PRB95 PRB96 PRB97 PRB98 PRB99

Unit count count count count count count count

Description IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB IOT level count for each PRB

Visible Y Y Y Y Y Y Y

Counter Type CC CC CC CC CC CC CC

Trigger Type 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s. 5.12 s.

Data Type int int int int int int int

Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 343 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

21 MLBO
21.1 Load
This section provides statistics for mobility load balancing operation. Index
Name cNum Range 0~2 Description Serving Cell Index

Type
Name LoadIndicatorAvg Unit % Description Average load of a cell when overload occurs due to the MLBO operation LoadIndicatorMin % Minimum load of a cell when overload occurs due to the MLBO operation LoadIndicatorMax % Maximum load of a cell when overload occurs due to the MLBO operation LoadIndicatorTot % Accumulated load of a cell when overload occurs due to the MLBO operation Y GAUGE 5s float 0-100 Y GAUGE 5s float 0-100 max (LoadIndicatorMax) Y GAUGE 5s float 0-100 min (LoadIndicatorMin) Visible Y Counter Type GAUGE Trigger Type 5s Data Type float Min/Max 0-100 Granularity Formula LoadIndicatorTot/ LoadIndicatorCnt Hourly, Daily, Monthly Formula sum (LoadIndicatorTot)/ sum (LoadIndicatorCnt)

SAMSUNG Electronics Co., Ltd.

page 344 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name LoadIndicatorCnt

Unit count

Description The number of LoadIndicatorAvg called

Visible Y

Counter Type GAUGE

Trigger Type 5s

Data Type int

Min/Max 0-2147483647 -

Granularity Formula

Hourly, Daily, Monthly Formula -

OverloadCount

count

The number of overload occurrences due to the MLBO operation

CC

5s

int

0-2147483647

MlbDurationAvg

Average of the overload period due to the MLBO operation

GAUGE

5s

float

0-100

MlbDurationTot/M lbDurationCnt

sum (MlbDurationTot)/ sum (MlbDurationCnt)

MlbDurationMin

Minimum value of the overload period due to the MLBO operation

GAUGE

5s

float

0-100

min (MlbDurationMin)

MlbDurationMax

Maximum value of the overload period due to the MLBO operation

GAUGE

5s

float

0-100

max (MlbDurationMax)

MlbDurationTot

Accumulated value of the overload period due to the MLBO operation

GAUGE

5s

float

0-100

MlbDurationCnt

count

The number of MlbDurationAvg called

GAUGE

5s

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 345 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

21.2 Load Balancing Handover


This section provides statistics for handovers that are performed by SON load balancing. Index
Name cNum tcId Step 0~2 0~268435455 1~3 Range Serving Cell Index Target Cell Index Load Balancing Handover Triggering Step 1: LBHO within the same group & sector 2: LBHO between different groups but the same sector (the same eNB) 3: LBHO between different sectors Description

Type
Name MlbNotTriggeredB yLoadCondition Unit count Description The number of times when there is no candidate neighbor cell that meets the load condition although MLB is triggered (collected only at Step 3) MlbNotTriggeredB yRadioCondition count The number of times when there is no candidate UE because radio condition is not met although MLB is triggered (collected only at Step 3) MlbHOAtt count The number of handover attempts when MLB is triggered Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 346 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name MlbHOSucc

Unit count

Description The number of successful handovers when MLB is triggered

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

LbhoCnt

count

Load Balancing handover collection count

CC

event

int

0~2147483647

LbhoCid

tcID

tcID of which collection is requested

OW

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 347 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

22 Message
22.1 Protocol Message
This section provides statistics for (RRC/S1AP/X2AP) protocol messages transmitted/received by eNB. Index
Name PLMN cNum 0~268435455 0~2 Range PLMN Cell Index Description

Type
Name RrcMsgSnd Unit count Description The number of times that the eNB transmits an RRC protocol message RrcMsgRcv count The number of times that the eNB receives an RRC protocol message S1MsgSnd count The number of times that the eNB transmits an S1AP protocol message S1MsgRcv count The number of times that the eNB receives an S1AP protocol message X2MsgSnd count The number of times that the eNB transmits an X2AP protocol message X2MsgRcv count The number of times that the eNB receives am X2AP protocol message Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 348 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

22.2 RRC Message


Describes the RRC Message statistics transmitted/received by the eNB. Type
Name TotalRrc_Tx Unit count Description Number of Total RRC Message transmitted by the eNB TotalRrc_Rx count Number of Total RRC Message received by the eNB RrcCounterChe ck RrcCounterChe ckResponse count count Number of RrcCounterCheck Message transmitted/received by the eNB Number of RrcCounterCheckResponse Message transmitted/received by the eNB RrcCSFBParam etersRequestC DMA2000 count Number of RrcCSFBParametersRequestCDMA20 00 Message transmitted/received by the eNB RrcCSFBParam etersResponse CDMA2000 count Number of RrcCSFBParametersResponseCDMA2 000 Message transmitted/received by the eNB RrcDLInformati onTransfer count Number of RrcDLInformationTransfer Message transmitted/received by the eNB Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 349 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RrcHandoverFr omEUTRAPrep arationRequest

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RrcHandoverFromEUTRAPreparationR equest Message transmitted/received by the eNB

RrcMeasureme ntReport

count

Number of RrcMeasurementReport Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcMobilityFro mEUTRAComm and

count

Number of RrcMobilityFromEUTRACommand Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionReconfigura tion

count

Number of RrcRRCConnectionReconfiguration Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionReconfigura tionComplete

count

Number of RrcRRCConnectionReconfigurationCo mplete Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionReestablish ment

count

Number of RrcRRCConnectionReestablishment Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionReestablish mentComplete

count

Number of RrcRRCConnectionReestablishmentCo mplete Message transmitted/received

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 350 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit by the eNB

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

RrcRRCConnec tionReestablish mentReject

count

Number of RrcRRCConnectionReestablishmentRe ject Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionReestablish mentRequest

count

Number of RrcRRCConnectionReestablishmentRe quest Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionReject

count

Number of RrcRRCConnectionReject Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionRelease

count

Number of RrcRRCConnectionRelease Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionRequest

count

Number of RrcRRCConnectionRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionSetup

count

Number of RrcRRCConnectionSetup Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcRRCConnec tionSetupCompl ete

count

Number of RrcRRCConnectionSetupComplete Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 351 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RrcSecurityMod eCommand

Unit count

Description Number of RrcSecurityModeCommand Message transmitted/received by the eNB

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RrcSecurityMod eComplete

count

Number of RrcSecurityModeComplete Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcSecurityMod eFailure

count

Number of RrcSecurityModeFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcUECapabilit yEnquiry

count

Number of RrcUECapabilityEnquiry Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcUECapabilit yInformation

count

Number of RrcUECapabilityInformation Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcULHandover PreparationTran sfer

count

Number of RrcULHandoverPreparationTransfer Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcULInformati onTransfer

count

Number of RrcULInformationTransfer Message transmitted/received by the eNB

CC

event

int

0~2147483647

RrcUEInformati onRequest

count

Number of RrcUEInformationRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 352 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RrcUEInformati onResponse

Unit count

Description Number of RrcUEInformationResponse Message transmitted/received by the eNB

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RrcProximityInd ication

count

Number of RrcProximityIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 353 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

22.3 S1AP Message


Describes the S1AP Message statistics transmitted/received from the eNB. Type
Name TotalS1ap_Tx Unit count Description Number of Total S1AP Message transmitted by the eNB TotalS1ap_Rx count Number of Total S1AP Message received by the eNB S1apCellTraffic Trace count Number of S1apCellTrafficTrace Message transmitted/received by the eNB S1apDeactivate Trace count Number of S1apDeactivateTrace Message transmitted/received by the eNB S1apDownlinkN ASTransport count Number of S1apDownlinkNASTransport Message transmitted/received by the eNB S1apDownlinkS cdma2000tunne ling count Number of S1apDownlinkScdma2000tunneling Message transmitted/received by the eNB S1apENBConfig urationTransfer count Number of S1apENBConfigurationTransfer Message transmitted/received by the Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 354 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit eNB

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

S1apENBConfig urationUpdate

count

Number of S1apENBConfigurationUpdate Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apENBConfig urationUpdateA cknowledge

count

Number of S1apENBConfigurationUpdateAcknowl edge Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apENBConfig urationUpdateF ailure

count

Number of S1apENBConfigurationUpdateFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apENBDirectI nformationTrans fer

count

Number of S1apENBDirectInformationTransfer Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apENBStatus Transfer

count

Number of S1apENBStatusTransfer Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apERABModi fyRequest

count

Number of S1apERABModifyRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apERABModi fyResponse

count

Number of S1apERABModifyResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 355 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S1apERABRele aseCommand

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

S1apERABReleaseCommand Message transmitted/received by the eNB

S1apERABRele aseResponse

count

Number of S1apERABReleaseResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apERABRele aseIndication

count

Number of S1apERABReleaseIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apERABSetu pRequest

count

Number of S1apERABSetupRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apERABSetu pResponse

count

Number of S1apERABSetupResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apErrorIndica tion

count

Number of S1apErrorIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandover Cancel

count

Number of S1apHandoverCancel Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandover CancelAcknowl edge

count

Number of S1apHandoverCancelAcknowledge Message transmitted/received by the

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 356 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit eNB

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

S1apHandover Command

count

Number of S1apHandoverCommand Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandoverF ailure

count

Number of S1apHandoverFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandover Notify

count

Number of S1apHandoverNotify Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandoverP reparationFailur e

count

Number of S1apHandoverPreparationFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandover Request

count

Number of S1apHandoverRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandover RequestAcknow ledge

count

Number of S1apHandoverRequestAcknowledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apHandover Required

count

Number of S1apHandoverRequired Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apInitialConte

count

Number of

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 357 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name xtSetupFailure

Unit

Description S1apInitialContextSetupFailure Message transmitted/received by the eNB

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

S1apInitialConte xtSetupRequest

count

Number of S1apInitialContextSetupRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apInitialConte xtSetupRespons e

count

Number of S1apInitialContextSetupResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apInitialUEM essage

count

Number of S1apInitialUEMessage Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apLocationR eportingControl

count

Number of S1apLocationReportingControl Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apLocationR eportFailureIndi cation

count

Number of S1apLocationReportFailureIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apLocationR eport

count

Number of S1apLocationReport Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apMMEConfi

count

Number of

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 358 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name gurationTransfer

Unit

Description S1apMMEConfigurationTransfer Message transmitted/received by the eNB

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

S1apMMEConfi gurationUpdate

count

Number of S1apMMEConfigurationUpdate Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apMMEConfi gurationUpdate Acknowledge

count

Number of S1apMMEConfigurationUpdateAcknow ledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apMMEConfi gurationUpdate Failure

count

Number of S1apMMEConfigurationUpdateFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apMMEDirect InformationTran sfer

count

Number of S1apMMEDirectInformationTransfer Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apMMEStatu sTransfer

count

Number of S1apMMEStatusTransfer Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apNASNonD eliveryIndication

count

Number of S1apNASNonDeliveryIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 359 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S1apOverloadSt art

Unit count

Description Number of S1apOverloadStart Message transmitted/received by the eNB

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

S1apOverloadSt op

count

Number of S1apOverloadStop Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apPaging

count

Number of S1apPaging Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apPathSwitch Request

count

Number of S1apPathSwitchRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apPathSwitch RequestAcknow ledge

count

Number of S1apPathSwitchRequestAcknowledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apPathSwitch RequestFailure

count

Number of S1apPathSwitchRequestFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apReset

count

Number of S1apReset Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apResetAckn owledge

count

Number of S1apResetAcknowledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apSetupFailu

count

Number of S1apSetupFailure Message

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 360 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name re S1apSetupRequ est

Unit

Description transmitted/received by the eNB

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

count

Number of S1apSetupRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apSetupResp onse

count

Number of S1apSetupResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apTraceFailu reIndication

count

Number of S1apTraceFailureIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apTraceStart

count

Number of S1apTraceStart Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUECapabili tyInfoIndication

count

Number of S1apUECapabilityInfoIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUEContext ModificationFail ure

count

Number of S1apUEContextModificationFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUEContext ModificationReq uest

count

Number of S1apUEContextModificationRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUEContext

count

Number of

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 361 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ModificationRes ponse

Unit

Description S1apUEContextModificationResponse Message transmitted/received by the eNB

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

S1apUEContext ReleaseComma nd

count

Number of S1apUEContextReleaseCommand Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUEContext ReleaseComple te

count

Number of S1apUEContextReleaseComplete Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUEContext ReleaseRequest

count

Number of S1apUEContextReleaseRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUplinkNAS Transport

count

Number of S1apUplinkNASTransport Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUplinkScd ma2000tunneling

count

Number of S1apUplinkScdma2000tunneling Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apWriteRepla ceWarningRequ est

count

Number of S1apWriteReplaceWarningRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 362 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name S1apWriteRepla ceWarningResp onse

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

S1apWriteReplaceWarningResponse Message transmitted/received by the eNB

S1apKillRequest

count

Number of S1apKillRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apKillRespon se

count

Number of S1apKillResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apDownlinkU EAssociatedLP PaTransport

count

Number of S1apDownlinkUEAssociatedLPPaTran sport Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUplinkUEA ssociatedLPPaT ransport

count

Number of S1apUplinkUEAssociatedLPPaTransp ort Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apDownlinkN onUEAssociate dLPPaTransport

count

Number of S1apDownlinkNonUEAssociatedLPPa Transport Message transmitted/received by the eNB

CC

event

int

0~2147483647

S1apUplinkNon UEAssociatedL PPaTransport

count

Number of S1apUplinkNonUEAssociatedLPPaTra nsport Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 363 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

22.4 X2AP Message


Describes the X2AP Message statistics transmitted/received from the eNB. Type
Name TotalX2ap_Tx Unit count Description Number of Total X2AP Message transmitted by the eNB TotalX2ap_Rx count Number of Total X2AP Message received by the eNB Tx_X2apErrorIn dication count Number of Tx_X2apErrorIndication Message transmitted/received by the eNB Tx_X2apHando verRequest count Number of Tx_X2apHandoverRequest Message transmitted/received by the eNB Tx_X2apHando verRequestAck nowledge count Number of Tx_X2apHandoverRequestAcknowledg e Message transmitted/received by the eNB Tx_X2apHando verPreparationF ailure count Number of Tx_X2apHandoverPreparationFailure Message transmitted/received by the eNB Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Y CC event int 0~2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 364 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Tx_X2apSNStat usTransfer

Unit count

Description Number of Tx_X2apSNStatusTransfer Message transmitted/received by the eNB

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Tx_X2apUECon textRelease

count

Number of Tx_X2apUEContextRelease Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apHando verCancel

count

Number of Tx_X2apHandoverCancel Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apLoadIn formation

count

Number of Tx_X2apLoadInformation Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apReset Request

count

Number of Tx_X2apResetRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apReset Response

count

Number of Tx_X2apResetResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apX2Set upRequest

count

Number of Tx_X2apX2SetupRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apX2Set upResponse

count

Number of Tx_X2apX2SetupResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 365 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Tx_X2apX2Set upFailure

Unit count

Description Number of Tx_X2apX2SetupFailure Message transmitted/received by the eNB

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Tx_X2apENBC onfigurationUpd ate

count

Number of Tx_X2apENBConfigurationUpdate Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apENBC onfigurationUpd ateAcknowledg e Tx_X2apENBC onfigurationUpd ateFailure

count

Number of Tx_X2apENBConfigurationUpdateAckn owledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

count

Number of Tx_X2apENBConfigurationUpdateFailur e Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apResour ceStatusReque st

count

Number of Tx_X2apResourceStatusRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apResour ceStatusRespo nse

count

Number of Tx_X2apResourceStatusResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 366 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Tx_X2apResour ceStatusFailure

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Tx_X2apResourceStatusFailure Message transmitted/received by the eNB

Tx_X2apResour ceStatusUpdate

count

Number of Tx_X2apResourceStatusUpdate Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apHando verReport

count

Number of Tx_X2apHandoverReport Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apMobilit yChangeReque st

count

Number of Tx_X2apMobilityChangeRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apMobilit yChangeAckno wledge

count

Number of Tx_X2apMobilityChangeAcknowledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apMobilit yChangeFailure

count

Number of Tx_X2apMobilityChangeFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 367 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Tx_X2apCellAct ivationRequest

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Tx_X2apCellActivationRequest Message transmitted/received by the eNB

Tx_X2apCellActi vationResponse

count

Number of Tx_X2apCellActivationResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apCellAct ivationFailure

count

Number of Tx_X2apCellActivationFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

Tx_X2apRadioL inkFailureIndica tion

count

Number of Tx_X2apRadioLinkFailureIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apErrorIn dication

count

Number of Rx_X2apErrorIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apHando verRequest

count

Number of Rx_X2apHandoverRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apHando verRequestAck nowledge

count

Number of Rx_X2apHandoverRequestAcknowledg e Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 368 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Rx_X2apHando verPreparationF ailure

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Rx_X2apHandoverPreparationFailure Message transmitted/received by the eNB

Rx_X2apSNStat usTransfer

count

Number of Rx_X2apSNStatusTransfer Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apUECo ntextRelease

count

Number of Rx_X2apUEContextRelease Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apHando verCancel

count

Number of Rx_X2apHandoverCancel Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apLoadIn formation

count

Number of Rx_X2apLoadInformation Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apReset Request

count

Number of Rx_X2apResetRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apReset Response

count

Number of Rx_X2apResetResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apX2Set upRequest

count

Number of Rx_X2apX2SetupRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 369 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Rx_X2apX2Set upResponse

Unit count

Description Number of Rx_X2apX2SetupResponse Message transmitted/received by the eNB

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Rx_X2apX2Set upFailure

count

Number of Rx_X2apX2SetupFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apENBC onfigurationUpd ate

count

Number of Rx_X2apENBConfigurationUpdate Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apENBCo nfigurationUpdat eAcknowledge

count

Number of Rx_X2apENBConfigurationUpdateAckn owledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apENBC onfigurationUpd ateFailure

count

Number of Rx_X2apENBConfigurationUpdateFailur e Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apResou rceStatusReque st

count

Number of Rx_X2apResourceStatusRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apResou rceStatusRespo nse

count

Number of Rx_X2apResourceStatusResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 370 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Rx_X2apResou rceStatusFailure

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Rx_X2apResourceStatusFailure Message transmitted/received by the eNB

Rx_X2apResour ceStatusUpdate

count

Number of Rx_X2apResourceStatusUpdate Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apHando verReport

count

Number of Rx_X2apHandoverReport Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apMobilit yChangeReque st

count

Number of Rx_X2apMobilityChangeRequest Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apMobilit yChangeAckno wledge

count

Number of Rx_X2apMobilityChangeAcknowledge Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apMobilit yChangeFailure

count

Number of Rx_X2apMobilityChangeFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 371 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name Rx_X2apCellAc tivationRequest

Unit count Number of

Description

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0~2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

Rx_X2apCellActivationRequest Message transmitted/received by the eNB

Rx_X2apCellActi vationResponse

count

Number of Rx_X2apCellActivationResponse Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apCellAc tivationFailure

count

Number of Rx_X2apCellActivationFailure Message transmitted/received by the eNB

CC

event

int

0~2147483647

Rx_X2apRadio LinkFailureIndic ation

count

Number of Rx_X2apRadioLinkFailureIndication Message transmitted/received by the eNB

CC

event

int

0~2147483647

SAMSUNG Electronics Co., Ltd.

page 372 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

23 Traffic OAM
23.1 Throughput Distribution
This section provides statistics for packet throughput distribution. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name UlThruBin1 Unit count Description Number of uplink RBs with 0 Kbps throughput < 100 Kbps UlThruBin2 count Number of uplink RBs with 100 Kbps throughput < 200 Kbps UlThruBin3 count Number of uplink RBs with 200 Kbps throughput < 300 Kbps UlThruBin4 count Number of uplink RBs with 300 Kbps throughput < 400 Kbps UlThruBin5 count Number of uplink RBs with 400 Kbps throughput < 500 Kbps Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 373 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin6

Unit count

Description Number of uplink RBs with 500 Kbps throughput < 600 Kbps Number of uplink RBs with 600 Kbps throughput < 700 Kbps Number of uplink RBs with 700 Kbps throughput < 800 Kbps Number of uplink RBs with 800 Kbps throughput < 900 Kbps Number of uplink RBs with 900 Kbps throughput < 1000 Kbps Number of uplink RBs with 1000 Kbps throughput < 1200 Kbps Number of uplink RBs with 1200 Kbps throughput < 1400 Kbps Number of uplink RBs with 1400 Kbps throughput < 1600 Kbps Number of uplink RBs with 1600 Kbps throughput < 1800 Kbps Number of uplink RBs with 1800 Kbps throughput < 2000 Kbps Number of uplink RBs with 2000 Kbps throughput < 2200 Kbps Number of uplink RBs with 22000 Kbps throughput < 2400 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin7

count

CC

event

int

0-2147483647

UlThruBin8

count

CC

event

int

0-2147483647

UlThruBin9

count

CC

event

int

0-2147483647

UlThruBin10

count

CC

event

int

0-2147483647

UlThruBin11

count

CC

event

int

0-2147483647

UlThruBin12

count

CC

event

int

0-2147483647

UlThruBin13

count

CC

event

int

0-2147483647

UlThruBin14

count

CC

event

int

0-2147483647

UlThruBin15

count

CC

event

int

0-2147483647

UlThruBin16

count

CC

event

int

0-2147483647

UlThruBin17

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 374 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin18

Unit count

Description Number of uplink RBs with 2400 Kbps throughput < 2600 Kbps Number of uplink RBs with 2600 Kbps throughput < 2800 Kbps Number of uplink RBs with 2800 Kbps throughput < 3000 Kbps Number of uplink RBs with 3000 Kbps throughput < 3400 Kbps Number of uplink RBs with 3400 Kbps throughput < 3800 Kbps Number of uplink RBs with 3800 Kbps throughput < 4200 Kbps Number of uplink RBs with 4200 Kbps throughput < 4600 Kbps Number of uplink RBs with 4600 Kbps throughput < 5000 Kbps Number of uplink RBs with 5000 Kbps throughput < 5400 Kbps Number of uplink RBs with 5400 Kbps throughput < 5800 Kbps Number of uplink RBs with 5800 Kbps throughput < 6200 Kbps Number of uplink RBs with 6200 Kbps throughput < 6600 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin19

count

CC

event

int

0-2147483647

UlThruBin20

count

CC

event

int

0-2147483647

UlThruBin21

count

CC

event

int

0-2147483647

UlThruBin22

count

CC

event

int

0-2147483647

UlThruBin23

count

CC

event

int

0-2147483647

UlThruBin24

count

CC

event

int

0-2147483647

UlThruBin25

count

CC

event

int

0-2147483647

UlThruBin26

count

CC

event

int

0-2147483647

UlThruBin27

count

CC

event

int

0-2147483647

UlThruBin28

count

CC

event

int

0-2147483647

UlThruBin29

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 375 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin30

Unit count

Description Number of uplink RBs with 6600 Kbps throughput < 7000 Kbps Number of uplink RBs with 7000 Kbps throughput < 7800 Kbps Number of uplink RBs with 7800 Kbps throughput < 8600 Kbps Number of uplink RBs with 8600 Kbps throughput < 9400 Kbps Number of uplink RBs with 9400 Kbps throughput < 10200 Kbps Number of uplink RBs with 10200 Kbps throughput < 11000 Kbps Number of uplink RBs with 11000 Kbps throughput < 11800 Kbps Number of uplink RBs with 11800 Kbps throughput < 12600 Kbps Number of uplink RBs with 12600 Kbps throughput < 13400 Kbps Number of uplink RBs with 13400 Kbps throughput < 14200 Kbps Number of uplink RBs with 14200 Kbps throughput < 15000 Kbps Number of uplink RBs with 15000 Kbps throughput < 16600 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin31

count

CC

event

int

0-2147483647

UlThruBin32

count

CC

event

int

0-2147483647

UlThruBin33

count

CC

event

int

0-2147483647

UlThruBin34

count

CC

event

int

0-2147483647

UlThruBin35

count

CC

event

int

0-2147483647

UlThruBin36

count

CC

event

int

0-2147483647

UlThruBin37

count

CC

event

int

0-2147483647

UlThruBin38

count

CC

event

int

0-2147483647

UlThruBin39

count

CC

event

int

0-2147483647

UlThruBin40

count

CC

event

int

0-2147483647

UlThruBin41

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 376 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin42

Unit count

Description Number of uplink RBs with 16600 Kbps throughput < 18200 Kbps Number of uplink RBs with 18200 Kbps throughput < 19800 Kbps Number of uplink RBs with 19800 Kbps throughput < 21400 Kbps Number of uplink RBs with 21400 Kbps throughput < 23000 Kbps Number of uplink RBs with 23000 Kbps throughput < 24600 Kbps Number of uplink RBs with 24600 Kbps throughput < 26200 Kbps Number of uplink RBs with 26200 Kbps throughput < 27800 Kbps Number of uplink RBs with 27800 Kbps throughput < 29400 Kbps Number of uplink RBs with 29400 Kbps throughput < 31000 Kbps Number of uplink RBs with 31000 Kbps throughput < 34200 Kbps Number of uplink RBs with 34200 Kbps throughput < 37400 Kbps Number of uplink RBs with 37400 Kbps throughput < 40600 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin43

count

CC

event

int

0-2147483647

UlThruBin44

count

CC

event

int

0-2147483647

UlThruBin45

count

CC

event

int

0-2147483647

UlThruBin46

count

CC

event

int

0-2147483647

UlThruBin47

count

CC

event

int

0-2147483647

UlThruBin48

count

CC

event

int

0-2147483647

UlThruBin49

count

CC

event

int

0-2147483647

UlThruBin50

count

CC

event

int

0-2147483647

UlThruBin51

count

CC

event

int

0-2147483647

UlThruBin52

count

CC

event

int

0-2147483647

UlThruBin53

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 377 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin54

Unit count

Description Number of uplink RBs with 40600 Kbps throughput < 43800 Kbps Number of uplink RBs with 43800 Kbps throughput < 47000 Kbps Number of uplink RBs with 47000 Kbps throughput < 50200 Kbps Number of uplink RBs with 50200 Kbps throughput < 53400 Kbps Number of uplink RBs with 53400 Kbps throughput < 56600 Kbps Number of uplink RBs with 56600 Kbps throughput < 59800 Kbps Number of uplink RBs with 59800 Kbps throughput < 63000 Kbps Number of uplink RBs with 63000 Kbps throughput < 69400 Kbps Number of uplink RBs with 69400 Kbps throughput < 75800 Kbps Number of uplink RBs with 75800 Kbps throughput < 82200 Kbps Number of uplink RBs with 82200 Kbps throughput < 88600 Kbps Number of uplink RBs with 88600 Kbps throughput < 95000 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin55

count

CC

event

int

0-2147483647

UlThruBin56

count

CC

event

int

0-2147483647

UlThruBin57

count

CC

event

int

0-2147483647

UlThruBin58

count

CC

event

int

0-2147483647

UlThruBin59

count

CC

event

int

0-2147483647

UlThruBin60

count

CC

event

int

0-2147483647

UlThruBin61

count

CC

event

int

0-2147483647

UlThruBin62

count

CC

event

int

0-2147483647

UlThruBin63

count

CC

event

int

0-2147483647

UlThruBin64

count

CC

event

int

0-2147483647

UlThruBin65

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 378 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin66

Unit count

Description Number of uplink RBs with 95000 Kbps throughput < 101400 Kbps Number of uplink RBs with 101400 Kbps throughput < 107800 Kbps Number of uplink RBs with 107800 Kbps throughput < 114200 Kbps Number of uplink RBs with 114200 Kbps throughput < 120600 Kbps Number of uplink RBs with 120600 Kbps throughput < 127000 Kbps Number of uplink RBs with 127000 Kbps throughput < 139800 Kbps Number of uplink RBs with 139800 Kbps throughput < 152600 Kbps Number of uplink RBs with 152600 Kbps throughput < 165400 Kbps Number of uplink RBs with 165400 Kbps throughput < 178200 Kbps Number of uplink RBs with 178200 Kbps throughput < 191000 Kbps Number of uplink RBs with 191000 Kbps throughput < 203800 Kbps Number of uplink RBs with 203800 Kbps throughput < 216600 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin67

count

CC

event

int

0-2147483647

UlThruBin68

count

CC

event

int

0-2147483647

UlThruBin69

count

CC

event

int

0-2147483647

UlThruBin70

count

CC

event

int

0-2147483647

UlThruBin71

count

CC

event

int

0-2147483647

UlThruBin72

count

CC

event

int

0-2147483647

UlThruBin73

count

CC

event

int

0-2147483647

UlThruBin74

count

CC

event

int

0-2147483647

UlThruBin75

count

CC

event

int

0-2147483647

UlThruBin76

count

CC

event

int

0-2147483647

UlThruBin77

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 379 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin78

Unit count

Description Number of uplink RBs with 216600 Kbps throughput < 229400 Kbps Number of uplink RBs with 229400 Kbps throughput < 242200 Kbps Number of uplink RBs with 242200 Kbps throughput < 255000 Kbps Number of uplink RBs with 255000 Kbps throughput < 280600 Kbps Number of uplink RBs with 280600 Kbps throughput < 306200 Kbps Number of uplink RBs with 306200 Kbps throughput < 331800 Kbps Number of uplink RBs with 331800 Kbps throughput < 357400 Kbps Number of uplink RBs with 357400 Kbps throughput < 383000 Kbps Number of uplink RBs with 383000 Kbps throughput < 408600 Kbps Number of uplink RBs with 408600 Kbps throughput < 434200 Kbps Number of uplink RBs with 434200 Kbps throughput < 459800 Kbps Number of uplink RBs with 459800 Kbps throughput < 485400 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin79

count

CC

event

int

0-2147483647

UlThruBin80

count

CC

event

int

0-2147483647

UlThruBin81

count

CC

event

int

0-2147483647

UlThruBin82

count

CC

event

int

0-2147483647

UlThruBin83

count

CC

event

int

0-2147483647

UlThruBin84

count

CC

event

int

0-2147483647

UlThruBin85

count

CC

event

int

0-2147483647

UlThruBin86

count

CC

event

int

0-2147483647

UlThruBin87

count

CC

event

int

0-2147483647

UlThruBin88

count

CC

event

int

0-2147483647

UlThruBin89

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 380 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name UlThruBin90

Unit count

Description Number of uplink RBs with 485400 Kbps throughput < 511000 Kbps Number of uplink RBs with 511000 Kbps throughput < 562200 Kbps Number of uplink RBs with 562200 Kbps throughput < 613400 Kbps Number of uplink RBs with 613400 Kbps throughput < 664600 Kbps Number of uplink RBs with 664600 Kbps throughput < 715800 Kbps Number of uplink RBs with 715800 Kbps throughput < 767000 Kbps Number of uplink RBs with 767000 Kbps throughput < 818200 Kbps Number of uplink RBs with 818200 Kbps throughput < 869400 Kbps Number of uplink RBs with 869400 Kbps throughput < 920600 Kbps Number of uplink RBs with 920600 Kbps throughput < 971800 Kbps Number of uplink RBs with 971800 Kbps throughput < 1023000 Kbps Number of uplink RBs with throughput 1023000 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

UlThruBin91

count

CC

event

int

0-2147483647

UlThruBin92

count

CC

event

int

0-2147483647

UlThruBin93

count

CC

event

int

0-2147483647

UlThruBin94

count

CC

event

int

0-2147483647

UlThruBin95

count

CC

event

int

0-2147483647

UlThruBin96

count

CC

event

int

0-2147483647

UlThruBin97

count

CC

event

int

0-2147483647

UlThruBin98

count

CC

event

int

0-2147483647

UlThruBin99

count

CC

event

int

0-2147483647

UlThruBin100

count

CC

event

int

0-2147483647

UlThruBin101

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 381 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin1

Unit count

Description Number of downlink RBs with 0 Kbps throughput < 100 Kbps Number of downlink RBs with 100 Kbps throughput < 200 Kbps Number of downlink RBs with 200 Kbps throughput < 300 Kbps Number of downlink RBs with 300 Kbps throughput < 400 Kbps Number of downlink RBs with 400 Kbps throughput < 500 Kbps Number of downlink RBs with 500 Kbps throughput < 600 Kbps Number of downlink RBs with 600 Kbps throughput < 700 Kbps Number of downlink RBs with 700 Kbps throughput < 800 Kbps Number of downlink RBs with 800 Kbps throughput < 900 Kbps Number of downlink RBs with 900 Kbps throughput < 1000 Kbps Number of downlink RBs with 1000 Kbps throughput < 1200 Kbps Number of downlink RBs with 1200 Kbps throughput < 1400 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin2

count

CC

event

int

0-2147483647

DlThruBin3

count

CC

event

int

0-2147483647

DlThruBin4

count

CC

event

int

0-2147483647

DlThruBin5

count

CC

event

int

0-2147483647

DlThruBin6

count

CC

event

int

0-2147483647

DlThruBin7

count

CC

event

int

0-2147483647

DlThruBin8

count

CC

event

int

0-2147483647

DlThruBin9

count

CC

event

int

0-2147483647

DlThruBin10

count

CC

event

int

0-2147483647

DlThruBin11

count

CC

event

int

0-2147483647

DlThruBin12

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 382 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin13

Unit count

Description Number of downlink RBs with 1400 Kbps throughput < 1600 Kbps Number of downlink RBs with 1600 Kbps throughput < 1800 Kbps Number of downlink RBs with 1800 Kbps throughput < 2000 Kbps Number of downlink RBs with 2000 Kbps throughput < 2200 Kbps Number of downlink RBs with 2200 Kbps throughput < 2400 Kbps Number of downlink RBs with 2400 Kbps throughput < 2600 Kbps Number of downlink RBs with 2600 Kbps throughput < 2800 Kbps Number of downlink RBs with 2800 Kbps throughput < 3000 Kbps Number of downlink RBs with 3000 Kbps throughput < 3400 Kbps Number of downlink RBs with 3400 Kbps throughput < 3800 Kbps Number of downlink RBs with 3800 Kbps throughput < 4200 Kbps Number of downlink RBs with 4200 Kbps throughput < 4600 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin14

count

CC

event

int

0-2147483647

DlThruBin15

count

CC

event

int

0-2147483647

DlThruBin16

count

CC

event

int

0-2147483647

DlThruBin17

count

CC

event

int

0-2147483647

DlThruBin18

count

CC

event

int

0-2147483647

DlThruBin19

count

CC

event

int

0-2147483647

DlThruBin20

count

CC

event

int

0-2147483647

DlThruBin21

count

CC

event

int

0-2147483647

DlThruBin22

count

CC

event

int

0-2147483647

DlThruBin23

count

CC

event

int

0-2147483647

DlThruBin24

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 383 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin25

Unit count

Description Number of downlink RBs with 4600 Kbps throughput < 5000 Kbps Number of downlink RBs with 5000 Kbps throughput < 5400 Kbps Number of downlink RBs with 5400 Kbps throughput < 5800 Kbps Number of downlink RBs with 5800 Kbps throughput < 6200 Kbps Number of downlink RBs with 6200 Kbps throughput < 6600 Kbps Number of downlink RBs with 6600 Kbps throughput < 7000 Kbps Number of downlink RBs with 7000 Kbps throughput < 7800 Kbps Number of downlink RBs with 7800 Kbps throughput < 8600 Kbps Number of downlink RBs with 8600 Kbps throughput < 9400 Kbps Number of downlink RBs with 9400 Kbps throughput < 10200 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin26

count

CC

event

int

0-2147483647

DlThruBin27

count

CC

event

int

0-2147483647

DlThruBin28

count

CC

event

int

0-2147483647

DlThruBin29

count

CC

event

int

0-2147483647

DlThruBin30

count

CC

event

int

0-2147483647

DlThruBin31

count

CC

event

int

0-2147483647

DlThruBin32

count

CC

event

int

0-2147483647

DlThruBin33

count

CC

event

int

0-2147483647

DlThruBin34

count

CC

event

int

0-2147483647

DlThruBin35

count

Number of downlink RBs with 10200 Kbps throughput < 11000 Kbps

CC

event

int

0-2147483647

DlThruBin36

count

Number of downlink RBs with 11000 Kbps throughput < 11800 Kbps

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 384 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin37

Unit count

Description Number of downlink RBs with 11800 Kbps throughput < 12600 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin38

count

Number of downlink RBs with 12600 Kbps throughput < 13400 Kbps

CC

event

int

0-2147483647

DlThruBin39

count

Number of downlink RBs with 13400 Kbps throughput < 14200 Kbps

CC

event

int

0-2147483647

DlThruBin40

count

Number of downlink RBs with 14200 Kbps throughput < 15000 Kbps

CC

event

int

0-2147483647

DlThruBin41

count

Number of downlink RBs with 15000 Kbps throughput < 16600 Kbps

CC

event

int

0-2147483647

DlThruBin42

count

Number of downlink RBs with 16600 Kbps throughput < 18200 Kbps

CC

event

int

0-2147483647

DlThruBin43

count

Number of downlink RBs with 18200 Kbps throughput < 19800 Kbps

CC

event

int

0-2147483647

DlThruBin44

count

Number of downlink RBs with 19800 Kbps throughput < 21400 Kbps

CC

event

int

0-2147483647

DlThruBin45

count

Number of downlink RBs with 21400 Kbps throughput < 23000 Kbps

CC

event

int

0-2147483647

DlThruBin46

count

Number of downlink RBs with 23000 Kbps throughput < 24600 Kbps

CC

event

int

0-2147483647

DlThruBin47

count

Number of downlink RBs with 24600 Kbps throughput < 26200 Kbps

CC

event

int

0-2147483647

DlThruBin48

count

Number of downlink RBs with 26200 Kbps throughput < 27800 Kbps

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 385 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin49

Unit count

Description Number of downlink RBs with 27800 Kbps throughput < 29400 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin50

count

Number of downlink RBs with 29400 Kbps throughput < 31000 Kbps

CC

event

int

0-2147483647

DlThruBin51

count

Number of downlink RBs with 31000 Kbps throughput < 34200 Kbps

CC

event

int

0-2147483647

DlThruBin52

count

Number of downlink RBs with 34200 Kbps throughput < 37400 Kbps

CC

event

int

0-2147483647

DlThruBin53

count

Number of downlink RBs with 37400 Kbps throughput < 40600 Kbps

CC

event

int

0-2147483647

DlThruBin54

count

Number of downlink RBs with 40600 Kbps throughput < 43800 Kbps

CC

event

int

0-2147483647

DlThruBin55

count

Number of downlink RBs with 43800 Kbps throughput < 47000 Kbps

CC

event

int

0-2147483647

DlThruBin56

count

Number of downlink RBs with 47000 Kbps throughput < 50200 Kbps

CC

event

int

0-2147483647

DlThruBin57

count

Number of downlink RBs with 50200 Kbps throughput < 53400 Kbps

CC

event

int

0-2147483647

DlThruBin58

count

Number of downlink RBs with 53400 Kbps throughput < 56600 Kbps

CC

event

int

0-2147483647

DlThruBin59

count

Number of downlink RBs with 56600 Kbps throughput < 59800 Kbps

CC

event

int

0-2147483647

DlThruBin60

count

Number of downlink RBs with 59800 Kbps throughput < 63000 Kbps

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 386 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin61

Unit count

Description Number of downlink RBs with 63000 Kbps throughput < 69400 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin62

count

Number of downlink RBs with 69400 Kbps throughput < 75800 Kbps

CC

event

int

0-2147483647

DlThruBin63

count

Number of downlink RBs with 75800 Kbps throughput < 82200 Kbps

CC

event

int

0-2147483647

DlThruBin64

count

Number of downlink RBs with 82200 Kbps throughput < 88600 Kbps

CC

event

int

0-2147483647

DlThruBin65

count

Number of downlink RBs with 88600 Kbps throughput < 95000 Kbps

CC

event

int

0-2147483647

DlThruBin66

count

Number of downlink RBs with 95000 Kbps throughput < 101400 Kbps

CC

event

int

0-2147483647

DlThruBin67

count

Number of downlink RBs with 101400 Kbps throughput < 107800 Kbps

CC

event

int

0-2147483647

DlThruBin68

count

Number of downlink RBs with 107800 Kbps throughput < 114200 Kbps

CC

event

int

0-2147483647

DlThruBin69

count

Number of downlink RBs with 114200 Kbps throughput < 120600 Kbps

CC

event

int

0-2147483647

DlThruBin70

count

Number of downlink RBs with 120600 Kbps throughput < 127000 Kbps

CC

event

int

0-2147483647

DlThruBin71

count

Number of downlink RBs with 127000 Kbps throughput < 139800 Kbps

CC

event

int

0-2147483647

DlThruBin72

count

Number of downlink RBs with 139800 Kbps throughput < 152600 Kbps

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 387 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin73

Unit count

Description Number of downlink RBs with 152600 Kbps throughput < 165400 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin74

count

Number of downlink RBs with 165400 Kbps throughput < 178200 Kbps

CC

event

int

0-2147483647

DlThruBin75

count

Number of downlink RBs with 178200 Kbps throughput < 191000 Kbps

CC

event

int

0-2147483647

DlThruBin76

count

Number of downlink RBs with 191000 Kbps throughput < 203800 Kbps

CC

event

int

0-2147483647

DlThruBin77

count

Number of downlink RBs with 203800 Kbps throughput < 216600 Kbps

CC

event

int

0-2147483647

DlThruBin78

count

Number of downlink RBs with 216600 Kbps throughput < 229400 Kbps

CC

event

int

0-2147483647

DlThruBin79

count

Number of downlink RBs with 229400 Kbps throughput < 242200 Kbps

CC

event

int

0-2147483647

DlThruBin80

count

Number of downlink RBs with 242200 Kbps throughput < 255000 Kbps

CC

event

int

0-2147483647

DlThruBin81

count

Number of downlink RBs with 255000 Kbps throughput < 280600 Kbps

CC

event

int

0-2147483647

DlThruBin82

count

Number of downlink RBs with 280600 Kbps throughput < 306200 Kbps

CC

event

int

0-2147483647

DlThruBin83

count

Number of downlink RBs with 306200 Kbps throughput < 331800 Kbps

CC

event

int

0-2147483647

DlThruBin84

count

Number of downlink RBs with 331800 Kbps throughput < 357400 Kbps

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 388 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin85

Unit count

Description Number of downlink RBs with 357400 Kbps throughput < 383000 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin86

count

Number of downlink RBs with 383000 Kbps throughput < 408600 Kbps

CC

event

int

0-2147483647

DlThruBin87

count

Number of downlink RBs with 408600 Kbps throughput < 434200 Kbps

CC

event

int

0-2147483647

DlThruBin88

count

Number of downlink RBs with 434200 Kbps throughput < 459800 Kbps

CC

event

int

0-2147483647

DlThruBin89

count

Number of downlink RBs with 459800 Kbps throughput < 485400 Kbps

CC

event

int

0-2147483647

DlThruBin90

count

Number of downlink RBs with 485400 Kbps throughput < 511000 Kbps

CC

event

int

0-2147483647

DlThruBin91

count

Number of downlink RBs with 511000 Kbps throughput < 562200 Kbps

CC

event

int

0-2147483647

DlThruBin92

count

Number of downlink RBs with 562200 Kbps throughput < 613400 Kbps

CC

event

int

0-2147483647

DlThruBin93

count

Number of downlink RBs with 613400 Kbps throughput < 664600 Kbps

CC

event

int

0-2147483647

DlThruBin94

count

Number of downlink RBs with 664600 Kbps throughput < 715800 Kbps

CC

event

int

0-2147483647

DlThruBin95

count

Number of downlink RBs with 715800 Kbps throughput < 767000 Kbps

CC

event

int

0-2147483647

DlThruBin96

count

Number of downlink RBs with 767000 Kbps throughput < 818200 Kbps

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 389 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruBin97

Unit count

Description Number of downlink RBs with 818200 Kbps throughput < 869400 Kbps

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

DlThruBin98

count

Number of downlink RBs with 869400 Kbps throughput < 920600 Kbps

CC

event

int

0-2147483647

DlThruBin99

count

Number of downlink RBs with 920600 Kbps throughput < 971800 Kbps

CC

event

int

0-2147483647

DlThruBin100

count

Number of downlink RBs with 971800 Kbps throughput < 1023000 Kbps Number of downlink RBs with throughput 1023000 Kbps

CC

event

int

0-2147483647

DlThruBin101

count

CC

event

int

0-2147483647

UlThruAvg

Kbps

Average of the user uplink throughputs

GAUGE

event

int

0-2147483647

UlThruTot/U lThruCnt

sum (UlThruTot)/ sum (UlThruCnt) max (UlThruMax)

UlThruMax

Kbps

Maximum value of the user uplink throughput

GAUGE

event

int

0-2147483647

UlThruMin

Kbps

Minimum value of the user uplink throughput

GAUGE

event

int

0-2147483647

min (UlThruMin)

UlThruTot

Kbps

Sum of the user uplink throughputs collected

GAUGE

event

int

0-2147483647

UlThruCnt

count

Number of user uplink throughput collections

GAUGE

event

int

0-2147483647

DlThruAvg

Kbps

Average of the user downlink throughputs

GAUGE

event

int

0-2147483647

DlThruTot/D lThruCnt

sum (DlThruTot)/ sum (DlThruCnt) max (DlThruMax)

DlThruMax

Kbps

Maximum value of the user downlink throughputs

GAUGE

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 390 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name DlThruMin

Unit Kbps

Description Minimum value of the user downlink throughputs

Visible Y

Counter Type GAUGE

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula min (DlThruMin)

DlThruTot

Kbps

Sum of the user downlink throughputs collected

GAUGE

event

int

0-2147483647

DlThruCnt

count

Number of user downlink throughput collections

GAUGE

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 391 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

23.2 Delay Distribution


This section provides statistics for packet delay distribution. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name RlcDlDelayBin1 Unit count Description Number of downlink RBs with 0 ms delay < 10 ms RlcDlDelayBin2 count Number of downlink RBs with 10 ms delay < 20 ms RlcDlDelayBin3 count Number of downlink RBs with 20 ms delay < 30 ms RlcDlDelayBin4 count Number of downlink RBs with 30 ms delay < 40 ms RlcDlDelayBin5 count Number of downlink RBs with 40 ms delay < 50 ms RlcDlDelayBin6 count Number of downlink RBs with 50 ms delay < 60 ms Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Y CC event int 0-2147483647 Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 392 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RlcDlDelayBin7

Unit count

Description Number of downlink RBs with 60 ms delay < 70 ms Number of downlink RBs with 70 ms delay < 80 ms Number of downlink RBs with 80 ms delay < 90 ms Number of downlink RBs with 90 ms delay < 100 ms

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RlcDlDelayBin8

count

CC

event

int

0-2147483647

RlcDlDelayBin9

count

CC

event

int

0-2147483647

RlcDlDelayBin10

count

CC

event

int

0-2147483647

RlcDlDelayBin11

count

Number of downlink RBs with 100 ms delay < 110 ms

CC

event

int

0-2147483647

RlcDlDelayBin12

count

Number of downlink RBs with 110 ms delay < 120 ms

CC

event

int

0-2147483647

RlcDlDelayBin13

count

Number of downlink RBs with 120 ms delay < 130 ms

CC

event

int

0-2147483647

RlcDlDelayBin14

count

Number of downlink RBs with 130 ms delay < 140 ms

CC

event

int

0-2147483647

RlcDlDelayBin15

count

Number of downlink RBs with 140 ms delay < 150 ms

CC

event

int

0-2147483647

RlcDlDelayBin16

count

Number of downlink RBs with 150 ms delay < 160 ms

CC

event

int

0-2147483647

RlcDlDelayBin17

count

Number of downlink RBs with 160 ms delay < 170 ms

CC

event

int

0-2147483647

RlcDlDelayBin18

count

Number of downlink RBs with 170 ms delay < 180 ms

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 393 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RlcDlDelayBin19

Unit count

Description Number of downlink RBs with 180 ms delay < 190 ms

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RlcDlDelayBin20

count

Number of downlink RBs with 190 ms delay < 200 ms

CC

event

int

0-2147483647

RlcDlDelayBin21

count

Number of downlink RBs with 200 ms delay < 210 ms

CC

event

int

0-2147483647

RlcDlDelayBin22

count

Number of downlink RBs with 210 ms delay < 220 ms

CC

event

int

0-2147483647

RlcDlDelayBin23

count

Number of downlink RBs with 220 ms delay < 230 ms

CC

event

int

0-2147483647

RlcDlDelayBin24

count

Number of downlink RBs with 230 ms delay < 240 ms

CC

event

int

0-2147483647

RlcDlDelayBin25

count

Number of downlink RBs with 240 ms delay < 250 ms

CC

event

int

0-2147483647

RlcDlDelayBin26

count

Number of downlink RBs with 250 ms delay < 260 ms

CC

event

int

0-2147483647

RlcDlDelayBin27

count

Number of downlink RBs with 260 ms delay < 270 ms

CC

event

int

0-2147483647

RlcDlDelayBin28

count

Number of downlink RBs with 270 ms delay < 280 ms

CC

event

int

0-2147483647

RlcDlDelayBin29

count

Number of downlink RBs with 280 ms delay < 290 ms

CC

event

int

0-2147483647

RlcDlDelayBin30

count

Number of downlink RBs with 290 ms delay < 300 ms

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 394 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RlcDlDelayBin31

Unit count

Description Number of downlink RBs with 300 ms delay < 320 ms

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RlcDlDelayBin32

count

Number of downlink RBs with 320 ms delay < 340 ms

CC

event

int

0-2147483647

RlcDlDelayBin33

count

Number of downlink RBs with 340 ms delay < 360 ms

CC

event

int

0-2147483647

RlcDlDelayBin34

count

Number of downlink RBs with 360 ms delay < 380 ms

CC

event

int

0-2147483647

RlcDlDelayBin35

count

Number of downlink RBs with 380 ms delay < 400 ms

CC

event

int

0-2147483647

RlcDlDelayBin36

count

Number of downlink RBs with 400 ms delay < 420 ms

CC

event

int

0-2147483647

RlcDlDelayBin37

count

Number of downlink RBs with 420 ms delay < 440 ms

CC

event

int

0-2147483647

RlcDlDelayBin38

count

Number of downlink RBs with 440 ms delay < 460 ms

CC

event

int

0-2147483647

RlcDlDelayBin39

count

Number of downlink RBs with 460 ms delay < 480 ms

CC

event

int

0-2147483647

RlcDlDelayBin40

count

Number of downlink RBs with 480 ms delay < 500 ms

CC

event

int

0-2147483647

RlcDlDelayBin41

count

Number of downlink RBs with 500 ms delay < 550 ms

CC

event

int

0-2147483647

RlcDlDelayBin42

count

Number of downlink RBs with 550 ms delay < 600 ms

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 395 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RlcDlDelayBin43

Unit count

Description Number of downlink RBs with 600 ms delay < 650 ms

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RlcDlDelayBin44

count

Number of downlink RBs with 650 ms delay < 700 ms

CC

event

int

0-2147483647

RlcDlDelayBin45

count

Number of downlink RBs with 700 ms delay < 750 ms

CC

event

int

0-2147483647

RlcDlDelayBin46

count

Number of downlink RBs with 750 ms delay < 800 ms

CC

event

int

0-2147483647

RlcDlDelayBin47

count

Number of downlink RBs with 800 ms delay < 850 ms

CC

event

int

0-2147483647

RlcDlDelayBin48

count

Number of downlink RBs with 850 ms delay < 900 ms

CC

event

int

0-2147483647

RlcDlDelayBin49

count

Number of downlink RBs with 900 ms delay < 950 ms

CC

event

int

0-2147483647

RlcDlDelayBin50

count

Number of downlink RBs with 950 ms delay < 1000 ms

CC

event

int

0-2147483647

RlcDlDelayBin51

count

Number of downlink RBs with 1000 ms delay < 1100 ms

CC

event

int

0-2147483647

RlcDlDelayBin52

count

Number of downlink RBs with 1100 ms delay < 1200 ms

CC

event

int

0-2147483647

RlcDlDelayBin53

count

Number of downlink RBs with 1200 ms delay < 1300 ms

CC

event

int

0-2147483647

RlcDlDelayBin54

count

Number of downlink RBs with 1300 ms delay < 1400 ms

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 396 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RlcDlDelayBin55

Unit count

Description Number of downlink RBs with 1400 ms delay < 1500 ms

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RlcDlDelayBin56

count

Number of downlink RBs with 1500 ms delay < 1600 ms

CC

event

int

0-2147483647

RlcDlDelayBin57

count

Number of downlink RBs with 1600 ms delay < 1700 ms

CC

event

int

0-2147483647

RlcDlDelayBin58

count

Number of downlink RBs with 1700 ms delay < 1800 ms

CC

event

int

0-2147483647

RlcDlDelayBin59

count

Number of downlink RBs with 1800 ms delay < 1900 ms

CC

event

int

0-2147483647

RlcDlDelayBin60

count

Number of downlink RBs with 1900 ms delay < 2000 ms

CC

event

int

0-2147483647

RlcDlDelayBin61

count

Number of downlink RBs with 2000 ms delay < 2100 ms

CC

event

int

0-2147483647

RlcDlDelayBin62

count

Number of downlink RBs with 2100 ms delay < 2200 ms

CC

event

int

0-2147483647

RlcDlDelayBin63

count

Number of downlink RBs with 2200 ms delay < 2300 ms

CC

event

int

0-2147483647

RlcDlDelayBin64

count

Number of downlink RBs with 2300 ms delay < 2400 ms

CC

event

int

0-2147483647

RlcDlDelayBin65

count

Number of downlink RBs with 2400 ms delay < 2500 ms

CC

event

int

0-2147483647

RlcDlDelayBin66

count

Number of downlink RBs with 2500 ms delay < 2600 ms

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 397 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name RlcDlDelayBin67

Unit count

Description Number of downlink RBs with 2600 ms delay < 2700 ms

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

RlcDlDelayBin68

count

Number of downlink RBs with 2700 ms delay < 2800 ms

CC

event

int

0-2147483647

RlcDlDelayBin69

count

Number of downlink RBs with 2800 ms delay < 2900 ms

CC

event

int

0-2147483647

RlcDlDelayBin70

count

Number of downlink RBs with 2900 ms delay < 3000 ms Number of downlink RBs with delay 3000 ms

CC

event

int

0-2147483647

RlcDlDelayBin71

count

CC

event

int

0-2147483647

SAMSUNG Electronics Co., Ltd.

page 398 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

23.3 Drop Distribution


This section provides statistics for packet drop and loss distribution. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name PdcpSduDropRat eDlBin1 PdcpSduDropRat eDlBin2 PdcpSduDropRat eDlBin3 PdcpSduDropRat eDlBin4 PdcpSduDropRat eDlBin5 PdcpSduDropRat eDlBin6 count count count count count Unit count Description Number of downlink RBs with SDU packet drop rate 0 ppm Number of downlink RBs with 0 ppm <SDU packet drop rate 1 ppm Number of downlink RBs with 1 ppm <SDU packet drop rate 10 ppm Number of downlink RBs with 10 ppm <SDU packet drop rate 100 ppm Number of downlink RBs with 100 ppm <SDU packet drop rate 1000 ppm Number of downlink RBs with 1000 ppm <SDU packet drop rate 10000 ppm Y CC event int Y CC event int Y CC event int Y CC event int Y CC event int Visible Y Counter Type CC Trigger Type event Data Type int Min/Max 0-2147483 647 0-2147483 647 0-2147483 647 0-2147483 647 0-2147483 647 0-2147483 647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 399 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdcpSduDropRat eDlBin7 PdcpSduDropRat eDlBin8 RlcSduDropRate DlBin1 RlcSduDropRate DlBin2 RlcSduDropRate DlBin3 RlcSduDropRate DlBin4 RlcSduDropRate DlBin5 RlcSduDropRate DlBin6 RlcSduDropRate DlBin7 RlcSduDropRate DlBin8 PdcpSduLossRat eUlBin1 PdcpSduLossRat eUlBin2

Unit count

Description Number of downlink RBs with 10000 ppm <SDU packet drop rate 100000 ppm

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483 647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Number of downlink RBs with 100000 ppm <SDU packet drop rate 1000000 ppm

CC

event

int

0-2147483 647

count

Number of downlink RBs with PDU packet drop rate 0

CC

event

int

0-2147483 647

count

Number of downlink RBs with 0 < PDU packet drop rate 0.000001

CC

event

int

0-2147483 647

count

Number of downlink RBs with 0.000001 < PDU packet drop rate 0.00001

CC

event

int

0-2147483 647

count

Number of downlink RBs with 0.00001 < PDU packet drop rate 0.0001

CC

event

int

0-2147483 647

count

Number of downlink RBs with 0.0001 <PDU packet drop rate 0.001

CC

event

int

0-2147483 647

count

Number of downlink RBs with 0.001 < PDU packet drop rate 0.01

CC

event

int

0-2147483 647

count

Number of downlink RBs with 0.01 < PDU packet drop rate 0.1

CC

event

int

0-2147483 647

count

Number of downlink RBs with 0.1 < PDU packet drop rate 1

CC

event

int

0-2147483 647

count

Number of uplink RBs with SDU packet loss rate 0 ppm

CC

event

int

0-2147483 647

count

Number of uplink RBs with 0 ppm < SDU packet loss rate 1 ppm

CC

event

int

0-2147483 647

SAMSUNG Electronics Co., Ltd.

page 400 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name PdcpSduLossRat eUlBin3 PdcpSduLossRat eUlBin4 PdcpSduLossRat eUlBin5 PdcpSduLossRat eUlBin6 PdcpSduLossRat eUlBin7 PdcpSduLossRat eUlBin8

Unit count

Description Number of uplink RBs with 1 ppm < SDU packet loss rate 10 ppm

Visible Y

Counter Type CC

Trigger Type event

Data Type int

Min/Max 0-2147483 647

Granularity Formula -

Hourly, Daily, Monthly Formula -

count

Number of uplink RBs with 10 ppm < SDU packet loss rate 100 ppm

CC

event

int

0-2147483 647

count

Number of uplink RBs with 100 ppm < SDU packet loss rate 1000 ppm

CC

event

int

0-2147483 647

count

Number of uplink RBs with 1000 ppm < SDU packet loss rate 10000 ppm

CC

event

int

0-2147483 647

count

Number of uplink RBs with 10000 ppm < SDU packet loss rate 100000 ppm

CC

event

int

0-2147483 647

count

Number of uplink RBs with 100000 ppm < SDU packet loss rate 1000000 ppm

CC

event

int

0-2147483 647

SAMSUNG Electronics Co., Ltd.

page 401 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

23.4 CQI Distribution


This section provides statistics for CQI distribution. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name CqiBin1 CqiBin2 CqiBin3 CqiBin4 CqiBin5 CqiBin6 CqiBin7 CqiBin8 CqiBin9 CqiBin10 CqiBin11 Unit count count count count count count count count count count count Description Number of RBs that use CQI 1 Number of RBs that use CQI 2 Number of RBs that use CQI 3 Number of RBs that use CQI 4 Number of RBs that use CQI 5 Number of RBs that use CQI 6 Number of RBs that use CQI 7 Number of RBs that use CQI 8 Number of RBs that use CQI 9 Number of RBs that use CQI 10 Number of RBs that use CQI 11 Visible Y Y Y Y Y Y Y Y Y Y Y Counter Type CC CC CC CC CC CC CC CC CC CC CC Trigger Type event event event event event event event event event event event Data Type int int int int int int int int int int int Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 402 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name CqiBin12 CqiBin13 CqiBin14 CqiBin15 CqiBin16

Unit count count count count count

Description Number of RBs that use CQI 12 Number of RBs that use CQI 13 Number of RBs that use CQI 14 Number of RBs that use CQI 15 Number of RBs that use CQI 16

Visible Y Y Y Y Y

Counter Type CC CC CC CC CC

Trigger Type event event event event event

Data Type int int int int int

Min/Max 0-2147483647 0-2147483647 0-2147483647 0-2147483647 0-2147483647

Granularity Formula -

Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 403 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24 KPI
This section calculates the KPI defined as per 3GPP 32.450 and provides to the EMS.

24.1 ACCESSIBILITY
A KPI that shows probability for an end-user to be provided with an E-RAB at request. Probability success rate for E-RABs establishment. Successful attempts compared with total number of attempts for the different parts o f the E-RAB establishment.

SAEB.NbrSu ccEstabInit.QCI RRC.SuccCo nnEstab.cause S1SIG.Conn EstabSucc QCI A1 InitialEPS BEstabSR cause 100 RRC.AttConnEstab.cause S1SIG.Conn EstabAtt SAEB.NbrAttEstabInit.QCI
cause QCI

A2 AddedEPSBE stabSR

SAEB.NbrSuccEstabAdd.QCI
QCI

SAEB.NbrAttEstabAdd.QCI
QCI

100

Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

SAMSUNG Electronics Co., Ltd.

page 404 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Type
Name ErabAccessibili tyInit Unit % Description Initial E-RAB establishment success rate. E-RAB success/ERAB attempt Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-100 Granularity Formula (sumRrc_ConnEs tabSucc/sumRrc_ ConnEstabAtt)*(s umS1sig_S1Con nEstabSucc/sum S1sig_S1ConnEs tabAtt)*(sumErab _EstabInitSuccNb r/sumErab_EstabI nitAttNbr)*100 sumRrc_Conn EstabSucc sumRrc_Conn EstabAtt sumS1sig_S1C onnEstabSucc count count count Total RRC ESTAB success count Total RRC ESTAB attempt count Total UE Logical S1 Connection Setup success count sumS1sig_S1C onnEstabAtt count Total UE Logical S1 Connection Setup attempt count sumErab_Esta bInitSuccNbr sumErab_Esta bInitAttNbr count count Total ERAB setup success count Total ERAB setup attempt count OW Period int OW Period int 0~214748 3647 0~214748 3647 OW Period int 0~214748 3647 OW Period int OW Period int OW Period int 0~214748 3647 0~214748 3647 0~214748 3647 Hourly, Daily, Monthly Formula (sum (sumRrc_ConnEstabSucc)/sum (sumRrc_ConnEstabAtt))*(sum (sumS1sig_S1ConnEstabSucc)/ sum (sumS1sig_S1ConnEstabAtt))* (sum (sumErab_EstabInitSuccNbr)/ sum (sumErab_EstabInitAttNbr))*100 -

SAMSUNG Electronics Co., Ltd.

page 405 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name ErabAccessibili tyAdd

Unit %

Description Added E-RAB establishment success rate Added E-RAN success/Added ERAB attempt

Visible -

Counter Type OW

Trigger Type Period

Data Type float

Min/Max 0-100

Granularity Formula (sumErab_Estab AddSuccNbr/sum Erab_EstabAddAt tNbr)*100

Hourly, Daily, Monthly Formula (sum (sumErab_EstabAddSuccNbr)/ sum (sumErab_EstabAddAttNbr))*100

sumErab_Esta bAddSuccNbr sumErab_Esta bAddAttNbr ErabConnectio nFailureRate

count

Total ERAB additional setup success count

OW

Period

int

0~214748 3647

count

Total ERAB additional setup attempt count

OW

Period

int

0~214748 3647

Probability that an enduser is not provided with an E-RAB at the initial request

OW

Period

float

0-100

100ErabAccessibilityI nit

if ((sum (sumRrc_ConnEstabAtt)=0), 0, if ((sum (sumS1sig_S1ConnEstabAtt)=0), 0, if ((sum (sumErab_EstabInitAttNbr)= 0), 0, 100-ErabAccessibilityInit)))

SAMSUNG Electronics Co., Ltd.

page 406 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24.2 RETAINABILITY
A measurement that shows how often an end-user abnormally looses an E-RAB during the time the E-RAB is used. This statistics item is collected for each cell. SAEB. Re lAct .QCI QCI R2 SAEB.SessionTimeUE Index
Name cNum mcID 0~2 0~0 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) Description

Type
Name ErabRetainab ility Unit % Description Number of E-RABs with data in a buffer that was abnormally released Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-3.4*10^38 Granularity Formula sumRelActive/ RetainSession TimeUE*100 Hourly, Daily, Monthly Formula sum (sumRelActive)/ sum (RetainSessionTimeU E)*100 sumRelActive count Total count of bearers among active E-RABs where a call is released due to abnormal operation in eNB RetainSessio nTimeUE ms Total in-session time of the UE OW Period float 0~60*Period*1000 OW Period int 0 ~ 2147483647 -

SAMSUNG Electronics Co., Ltd.

page 407 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24.3 RETAINABILITY (QCI)


A measurement that shows how often an end-user abnormally looses an E-RAB during the time the E-RAB is used. This statistics item is collected for each QCI.

R1QCI x

ERAB . Re lActNbr _ QCIQCI x ERAB .SessionTimeQCI _ QCIQCI x

Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name Erab_Retaina bility Unit % Description Number of E-RABs with data in a buffer that was abnormally released Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0~3.4*10^ 38 Granularity Formula Retain_RelActive /Retain_Session TimeQCI * 100 Hourly, Daily, Monthly Formula sum (Retain_ RelActive)/sum (Retain_SessionTi meQCI) * 100 Retain_RelActi ve count Total count of bearers among active ERABs where a call is released due to abnormal operation in eNB Retain_Sessio nTimeQCI ms Total in-session time OW Period float 0~60*Peri od*1000 OW Period int 0~214748 3647 -

SAMSUNG Electronics Co., Ltd.

page 408 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24.4 INTEGRITY

A KPI that shows how E-UTRAN impacts the service quality provided to an end-user. Payload data volume on IP level per elapsed time unit on the Uu interface. E-UTRAN IP Throughput

V _ tp _ DL IP_ Throughput Samples

T _ tp _ DL
Samples

E-UTRAN IP Latency
Downlink LatQCI x DRB.IPLatDlQCI x

Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

SAMSUNG Electronics Co., Ltd.

page 409 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Type
Name EutranIpThroughput Unit Kbps Description EutranIpThroughput per QCI Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-3.4*10^38 Granularity Formula Hourly, Daily, Monthly Formula avg (EutranIpThroughput) EutranIpLatency ms EutranIpLatency per QCI Y OW Period float 0-60*Period*1000 avg (EutranIpLatency)

SAMSUNG Electronics Co., Ltd.

page 410 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24.5 AVAILABILITY

A KPI that shows availability of E-UTRAN cell. Percentage of time that the cell is considered available. For the cell availability, provides the statistics of the elapsed time from the cell down due to the fault until its recovery. E-UTRAN Cell Availability
measuremen t_period - RRU.CellUnavailableT ime.[cause ]
cause

CellAvaila bility

measurement _ period

100

Index
Name cNum Range 0~2 Description Cell Index

Type
Name EutranCellAvail ability Unit % Description Percentage of time that the cell is considered available Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-100 Granularity Formula (cellAvail_pmPeri odTimeread_CellUnavail ableTime)*100/c ellAvail_pmPerio dTime Hourly, Daily, Monthly Formula (sum (cellAvail_pmPeriodTi me)-sum (read_CellUnavailable Time))*100/sum (cellAvail_pmPeriodTi me)

SAMSUNG Electronics Co., Ltd.

page 411 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name read_CellUnav ailableTime cellAvail_pmPe riodTime s s

Unit

Description Disabled time per unit time

Visible -

Counter Type OW

Trigger Type Period

Data Type int

Min/Max 0~60*Period -

Granularity Formula -

Hourly, Daily, Monthly Formula

Data collection interval

OW

Period

int

0~60*Period

SAMSUNG Electronics Co., Ltd.

page 412 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24.6 MOBILITY

A KPI that shows how E-UTRAN Mobility functionality is working. Success rate of E-UTRAN mobility.
Mobility Success RateQCIx HO.ExeSucc HO.PrepSucc.QCI QCIx 100% HO.ExeAtt HO.PrepAtt .QCIQCIx

The handover is calculated for each case to produce the KPI.


Intra eNB Handover X2 Handover Out X2 Handover In S1 Handover Out S1 Handover In Inter-RAT Handover

HO.PrepAtt.QCI is calculated by HO.PrepSucc.QCI+HO.PrepFail.QCI. Index


Name cNum Range 0~2 Description Cell Index

SAMSUNG Electronics Co., Ltd.

page 413 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Type
Name EutranMobilityHOI ntra sumHOIntra_Att count Unit % Description HOIntra success rate of E-UTRAN mobility Total intra handover attempt count sumHOIntra_Succ count Total intra handover execution success count sumHOIntra_Prep Succ count Total intra handover preparation success count EutranMobilityHO X2Out % HOX2Out success rate of E-UTRAN mobility sumHOX2Out_Att count Total X2 handover attempt count in SeNB sumHOX2Out_Su cc count Total X2 handover execution success count in SeNB sumHOX2Out_Pr epSucc count Total X2 handover preparation success count in SeNB EutranMobilityHO X2In sumHOX2In_Att count % HOX2In success rate of E-UTRAN mobility Total X2 handover OW Period int 0~214748 Y OW Period float 0-100 sumHOX2In_Succ/(su mHOX2In_Att*100 sum (sumHOX2In_Succ)/ sum (sumHOX2In_Att)*100 OW Period int 0~214748 3647 OW Period int OW Period int 0~214748 3647 0~214748 3647 Y OW Period float 0-100 sumHOX2Out_Succ/s umHOX2Out_Att*100 sum (sumHOX2Out_Succ)/ sum (sumHOX2Out_Att)* 100 OW Period int 0~214748 3647 OW Period int OW Period int 0~214748 3647 0~214748 3647 Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0-100 Granularity Formula sumHOIntra_Succ/ sumHOIntra_Att*100 Hourly, Daily, Monthly Formula sum (sumHOIntra_Succ)/ sum (sumHOIntra_Att)*100 -

SAMSUNG Electronics Co., Ltd.

page 414 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description attempt count in TeNB

Visible

Counter Type

Trigger Type

Data Type

Min/Max 3647

Granularity Formula

Hourly, Daily, Monthly Formula

sumHOX2In_Succ

count

Total X2 handover execution success count in TeNB

OW

Period

int

0~214748 3647

sumHOX2In_Prep Succ

count

Total X2 handover preparation success count in TeNB

OW

Period

int

0~214748 3647

EutranMobilityHO S1Out

HOIS1Out success rate of E-UTRAN mobility

OW

Period

float

0-100

sumHOS1Out_Succ/s umHOS1Out_Att*100

sum (sumHOS1Out_Succ)/ sum (sumHOS1Out_Att)* 100

sumHOS1Out_Att

count

Total S1 handover attempt count in SeNB

OW

Period

int

0~214748 3647

sumHOS1Out_Su cc

count

Total S1 handover execution success count in SeNB

OW

Period

int

0~214748 3647

sumHOS1Out_Pr epSucc

count

Total S1 handover preparation success count in SeNB

OW

Period

int

0~214748 3647

EutranMobilityHO S1In sumHOS1In_Att

HOS1In success rate of E-UTRAN mobility

OW

Period

float

0-100

sumHOS1In_Succ/su mHOS1In_Att*100

sum (sumHOS1In_Succ)/ sum (sumHOS1In_Att)*100 -

count

Total S1 handover attempt count in TeNB

OW

Period

int

0~214748 3647

sumHOS1In_Succ

count

Total S1 handover execution success count in SeNB

OW

Period

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 415 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name sumHOS1In_Prep Succ

Unit count

Description Total S1 handover preparation success count in TeNB

Visible -

Counter Type OW

Trigger Type Period

Data Type int

Min/Max 0~214748 3647

Granularity Formula -

Hourly, Daily, Monthly Formula

EutranMobilityHOI nterRatHrpd (Not applicable for 3UK) sumHOInterRatHr pd_Att (Not applicable for 3UK) sumHOInterRatHr pd_Succ (Not applicable for 3UK) sumHOInterRatHr pd_PrepSucc (Not applicable for 3UK) EutranMobilityHOI nterRatUtranOut

HOInterRat success rate of E-UTRAN mobility

OW

Period

float

0-100

sumHOInterRatHrpd_ Succ/sumHOInterRat Hrpd_Att*100

sum (sumHOInterRatHrpd_ Succ)/sum (sumHOInterRatHrpd_Att)* 100

count

Total Inter RAT Optimized HRPD handover attempt count

OW

Period

int

0~214748 3647

count

Total Inter RAT Optimized HRPD handover execution success count

OW

Period

int

0~214748 3647

count

Total Inter RAT Optimized HRPD handover preparation success count

OW

Period

int

0~214748 3647

HOInterRatUtranOut rate of E-UTRAN mobility

OW

Period

float

0-100

sumHOInterRatUtran Out_Succ/sumHOInter RatUtranOut_Att*100

sum (sumHOInterRatUtranOut_ Succ)/sum (sumHOInterRatUtranOut_ Att)*100

sumHOInterRatUtr anOut_Att

count

Total LTE to Inter-RAT UTRAN handover

OW

Period

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 416 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description attempt count

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

sumHOInterRatUtr anOut_Succ

count

Total LTE to Inter-RAT UTRAN handover preparation failure count

OW

Period

int

0~214748 3647

sumHOInterRatUtr anOut_PrepSucc

count

Total LTE to Inter-RAT UTRAN handover preparation success count

OW

Period

int

0~214748 3647

EutranMobilityHOI nterRatUtranIn

HOInterRatUtranIn rate of E-UTRAN mobility

OW

Period

float

0-100

sumHOInterRatUtranI n_Succ/sumHOInterR atUtranIn_Att*100

sum (sumHOInterRatUtranIn_Su cc)/sum (sumHOInterRatUtranIn_Att )*100

sumHOInterRatUtr anIn_Att

count

Total Inter-RAT UTRAN to LTE handover attempt count

OW

Period

int

0~214748 3647

sumHOInterRatUtr anIn_Succ

count

Total Inter-RAT UTRAN to LTE handover execution success count

OW

Period

int

0~214748 3647

sumHOInterRatUtr anIn_PrepSucc

count

Total Inter-RAT UTRAN to LTE handover preparation success count

OW

Period

int

0~214748 3647

SAMSUNG Electronics Co., Ltd.

page 417 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name EutranMobilityHoI nter

Unit %

Description Probability that an end-user successfully completes a handover to a separate eNB of the same frequency

Visible Y

Counter Type OW

Trigger Type Period

Data Type float

Min/Max 0-100

Granularity Formula (sumHOS1Out_Succ+ sumHOX2Out_Succ)/( sumHOS1Out_Att+su mHOX2Out_Att)*100

Hourly, Daily, Monthly Formula (sum (sumHOS1Out_Succ)+sum (sumHOX2Out_Succ))/(su m (sumHOS1Out_Att)+sum (sumHOX2Out_Att))*100

SAMSUNG Electronics Co., Ltd.

page 418 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24.7 SUCCESS_RATE
RRC success rate, ERAB success rate, and call drop rate are calculated based on the RRC, ERAB, CALL_DROP, and HO statistics co llected. Index
Name cNum Range 0~2 Description Cell Index

Type
Name RrcEstabSuccess Ratio Unit % Description RRC ESTAB success rate Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0~100 Granularity Formula (SumRrcEstabSuccess/ SumRrcEstabAttempt)* 100 ErabEstabSuccess Ratio % ERAB ESTAB success rate Y OW Period float 0~100 (SumErabEstabSucces s/SumErabEstabAttem pt)*100 CallDropRatio ratio Call drop rate Y OW Period float 0~1 SumCallDrop_ECCB_D SP_AUDIT_RLC_MAC _CALL_RELEASE+Su mCallDrop_ECCB_RC V_RESET_REQUEST_ FROM_ECMB+SumCal lDrop_ECCB_RCV_CE LL_RELEASE_IND_FR OM_ECMB+SumCallDr Hourly, Daily, Monthly Formula (sum(SumRrcEstabSucc ess)/sum(SumRrcEstabA ttempt)) * 100 (sum(SumErabEstabSuc cess)/sum(SumErabEsta bAttempt)) * 100 sum(SumCallDrop_ECC B_DSP_AUDIT_RLC_M AC_CALL_RELEASE+Su mCallDrop_ECCB_RCV_ RESET_REQUEST_FRO M_ECMB+SumCallDrop_ ECCB_RCV_CELL_REL EASE_IND_FROM_ECM B+SumCallDrop_ECCB_

SAMSUNG Electronics Co., Ltd.

page 419 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula op_ECCB_RADIO_LIN K_FAILURE+SumCallD rop_ECCB_DSP_AUDI T_MAC_CALL_RELEA SE+SumCallDrop_ECC B_ARQ_MAX_RE_TRA NSMISSION+SumCall Drop_ECCB_DSP_AU DIT_RLC_CALL_RELE ASE+SumCallDrop_EC CB_TMOUT_rrcConne ctionReconfig+SumCall Drop_ECCB_TMOUT_r rcConnectionReEstabli sh+SumCallDrop_ECC B_S1_SCTP_OUT_OF _SERVICE/SumEstabIn itSuccNbr+SumInterX2I nSucc+SumInterS1InS ucc+SumRatInSuccUT RAN

Hourly, Daily, Monthly Formula RADIO_LINK_FAILURE+ SumCallDrop_ECCB_DS P_AUDIT_MAC_CALL_R ELEASE+SumCallDrop_ ECCB_ARQ_MAX_RE_T RANSMISSION+SumCall Drop_ECCB_DSP_AUDI T_RLC_CALL_RELEASE +SumCallDrop_ECCB_T MOUT_rrcConnectionRe config+SumCallDrop_EC CB_TMOUT_rrcConnecti onReEstablish+SumCall Drop_ECCB_S1_SCTP_ OUT_OF_SERVICE) / sum(SumEstabInitSuccN br+SumInterX2InSucc+S umInterS1InSucc+SumR atInSuccUTRAN)

SumRrcEstabAtte mpt

count

Total RRC ESTAB attempt count for each cell

OW

Period

int

0~21474 83647

SumRrcEstabSucc ess

count

Total RRC ESTAB success count for each cell

OW

Period

int

0~21474 83647

SAMSUNG Electronics Co., Ltd.

page 420 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name SumErabEstabAtt empt

Unit count

Description Total ERAB ESTAB attempt count for each cell

Visible -

Counter Type OW

Trigger Type Period

Data Type int

Min/Max 0~21474 83647 -

Granularity Formula -

Hourly, Daily, Monthly Formula

SumErabEstabSuc cess

count

Total ERAB ESTAB success count for each cell

OW

Period

int

0~21474 83647

SumCallDrop_EC CB_DSP_AUDIT_ RLC_MAC_CALL_ RELEASE

count

Total count that a call is released due to resource mismatch because the ECCB has remaining calls but the RLC and the MAC have no remaining calls

OW

Period

int

0~21474 83647

SumCallDrop_EC CB_RCV_RESET _REQUEST_FRO M_ECMB

count

Total count that a call is released when a reset request is received from the ECMB block due to refork of a specific block in the eNB

OW

Period

int

0~21474 83647

SumCallDrop_EC CB_RCV_CELL_R ELEASE_IND_FR OM_ECMB

count

Total count that a call is released when a Cell Release Ind message is received from the ECMB block because of DSP down

OW

Period

int

0~21474 83647

SAMSUNG Electronics Co., Ltd.

page 421 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description or CPRI failure caused by a problem in DSP

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

SumCallDrop_EC CB_RADIO_LINK _FAILURE SumCallDrop_EC CB_DSP_AUDIT_ MAC_CALL_REL EASE

count

Total count that a call is released due to radio link failure

OW

Period

int

0~21474 83647

count

Total count that a call is released due to resource mismatch because the ECCB and the RLC have remaining calls but the MAC has no remaining calls

OW

Period

int

0~21474 83647

SumCallDrop_EC CB_ARQ_MAX_R E_TRANSMISSIO N

count

Total count that a call is released when ARQ ACK is not received from the UE after the RLC performs as many transmission as the Max Retransmission to the UE.

OW

Period

int

0~21474 83647

SumCallDrop_EC CB_DSP_AUDIT_ RLC_CALL_RELE ASE

count

Total count that a call is released due to resource mismatch because the ECCB

OW

Period

int

0~21474 83647

SAMSUNG Electronics Co., Ltd.

page 422 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description and the MAC have remaining calls but the RLC has no remaining calls

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

SumCallDrop_EC CB_TMOUT_rrcC onnectionReconfig

count

Total count that a call is released when the RRC Connection Reconfiguration Complete message is not received after the RRC Connection Reconfiguration message is sent

OW

Period

int

0~21474 83647

SumCallDrop_EC CB_TMOUT_rrcC onnectionReEstabl ish

count

Total count that a call is released when the RRC Connection Reestablishment Complete message is not received after the RRC Connection Reestablishment message is sent

OW

Period

int

0~21474 83647

SumCallDrop_EC CB_S1_SCTP_O UT_OF_SERVICE

count

Total count that a call is released when the S1 Associations status is changed from In Service to Out of

OW

Period

int

0~21474 83647

SAMSUNG Electronics Co., Ltd.

page 423 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

Name

Unit

Description Service

Visible

Counter Type

Trigger Type

Data Type

Min/Max

Granularity Formula

Hourly, Daily, Monthly Formula

SumEstabInitSucc Nbr

count

Total ERAB ESTAB success count for each cell

OW

Period

int

0~21474 83647

SumInterX2InSucc

count

Total X2 handover execution success count for each cell in TeNB

OW

Period

int

0~21474 83647

SumInterS1InSucc

count

Total S1 handover execution success count for each cell in TeNB

OW

Period

int

0~21474 83647

SumRatInSuccUT RAN

count

Total Inter-RAT UTRAN to LTE handover execution success count for each cell

OW

Period

int

0~21474 83647

SAMSUNG Electronics Co., Ltd.

page 424 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

24.8 Connection Drop Rate


Indicates the ratio of number of abnormally terminated connections based on the number of created ERABs. Index
Name cNum mcID QCI 0~2 0~0 0~255 Range Cell Index Subcell Index (displayed only for smart cell configuration; included in the statistics) QoS Class Identifier Description

Type
Name ConnDropRate Unit % Description probability that an end-user abnormally lost an E-UTRAN Radio Access Bearer Visible Y Counter Type OW Trigger Type Period Data Type float Min/Max 0~100 Granularity Formula CdrRelActive/(Cd rSumEstabInitSuc cNbr+CdrEstabA ddSuccNbr)*100 CdrSumEstabI nitSuccNbr CdrEstabAddS uccNbr CdrRelActive count count coun Total ERAB ESTAB success count ERAB additional setup success count Total count of bearers among active E-RABs where a call is released due to abnormal operation in eNB OW Period int 0~2147483647 OW Period int 0~2147483647 OW Period int 0~2147483647 Hourly, Daily, Monthly Formula sum(CdrRelActive)/(s um(CdrSumEstabInit SuccNbr)+sum(CdrEs tabAddSuccNbr))*100 -

SAMSUNG Electronics Co., Ltd.

page 425 of 427

2600-00FET7GAT

Ver. 6.0 Statistics Items

25 UE_Category
25.1 UE Category
This section provides statistics for the number of UE for each UE Category. eNB performs count by Category of EMM-Registered UE. Type
Name UE_Category_1 UE_Category_2 UE_Category_3 UE_Category_4 UE_Category_5 Unit count count count count count Description The number of UE for UE Category 1 The number of UE for UE Category 2 The number of UE for UE Category 3 The number of UE for UE Category 4 The number of UE for UE Category 5 Visible Y Y Y Y Y Counter Type CC CC CC CC CC Trigger Type event event event event event Data Type int int int int int Min/Max 0~2147483647 0~2147483647 0~2147483647 0~2147483647 0~2147483647 Granularity Formula Hourly, Daily, Monthly Formula -

SAMSUNG Electronics Co., Ltd.

page 426 of 427

2600-00FET7GAT

Ver. 6.0

LTE eNB

System Counter Description _SLR2.4


2013 Samsung Electronics Co., Ltd. All rights reserved. Information in this manual is proprietary to SAMSUNG Electronics Co., Ltd. No information contained here may be copied, translated, transcribed or duplicated by any form without the prior written consent of SAMSUNG. Information in this manual is subject to change without notice.

SAMSUNG Electronics Co., Ltd.

page 427 of 427

You might also like