If its not broken dont x it! Its not normally necessary to open your PHEs in fact they should not be opened unless there is a clear reason to do so. If the pressure drop and performance are back to normal after the cleaning process, there is no reason to routinely open the PHE. Precautions worth taking If a PHE is about to be taken out of service, round off the cleaning cycle with a short alkaline cycle, followed by rinsing with water. This ensures that no acid is left in the unit that could cause corrosion during standstill. Acid cleaning agents must be weak solutions, such as, for example, phosphoric acid and sulphamic acid. Under no circumstances should hydrochloric acid be used.