Fire detection and re alarm systems for buildings Voice alarm systems Emergency lighting Other essential service circuits
Conductor
>
Plain annealed copper solid (1.0 - 1.5 mm2) or stranded (2.5 mm2) circular conductor complying with BS EN 60228 class 1 or class 2.
Insulation
>
> >
Laminated aluminium tape screen bonded to sheath and in contact with tinned annealed coppper 0.5mm drain wire which provides automatic screen earthing.
2
Sheath
>
Robust thermoplastic LSOH sheath Colour - White or Red. Other colours to special order For external exposure the use of a white sheath is recommended.
Flexibility Rigid
Ref: FP200Gold_Multi/01/09
Prysmian Cables & Systems Limited , Sales office, Chickenhall Lane, Eastleigh, Hants, SO50 6YU, UK Commercial Enquiries , Tel 0845 767 8345, Fax: 023 8029 5465 www.fpcables.co.uk
Conceptual Mean overall Approximate construction diameter cable weight no./mm mm kg/km
Recommended accessories Current Volt drop rating DC or single DC or single phase AC 2 1 Nylon LSOH phase AC LSOH Fixing Clips Clipped direct Gland Amps mV/A/m
Seven core
1.0 1.5 2.5 1/1.13 1/1.38 7/0.67 12.1 13.3 16.3 196 249 387 18.1 12.1 7.4 13* 16.5* 23* 15* 19.5* 27* 44 29 18 AP12 AP13 AP16 252 252 254
Twelve core
1.5 2.5 1/1.38 7/0.67 17.5 21.7 399 637 12.1 7.4 16.5 23* 19.5* 27* 29 18 AP18 AP22 254 255
Nineteen core
1.5 2.5
3
1/1.38 7/0.67
20.5 25.6
588 949
12.1 7.4
16.5 23*
19.5* 27*
29 18
AP20 AP25
255 -
Notes to table
1 2
Recommended clip spacing 300 mm and 400 mm vertical. Brass gland may be used as an alernative. 3 This size is not included in the latest (2008) edition of BS7629-1 and is therefore manufactured to BS7629-1:1997 Installation methods for current rating in accordance with BS7671/IEE Wiring Regulations. Minimum recommended installation temperature 0C. *The tabulated rating is as a two core and may be used where its number of cores carrying current does not exceed the square root of the total number of cores.
The tabulared ratings are based upon a 30C ambient temperature and 70C operating temperature. For other ambient temperatures or where cables are grouped toghether, the following rating factors should be applied.
25 1.03
30 1.00
35 0.94
40 0.87
45 0.79
50 0.71
55 0.61
60 0.50
2 0.80
3 0.70
4 0.65
5 0.60
6 0.57
7 0.54
8 0.52
9 0.50