You are on page 1of 9

The Journal of MaternalFetal and Neonatal Medicine 2004;16:171179

Vacuum-assisted delivery: a review


R. W. McQuivey
Clinical Innovations, Inc., Murray, Utah, USA

In 1992, the number of vacuum deliveries overtook the number of forceps deliveries performed in the USA. Most clinical experiences report that the vacuum is safe for both the fetus and the mother when used properly. Correct cup placement on the fetal head and knowing when to abandon the procedure, appear to be key components to conducting a safe and successful vacuum delivery. However, the focus and training that has been afforded forceps deliveries in the past has not been given to the vacuum, because of its perceived ease of use. This apparent lack of understanding has led to increasing numbers of complications associated with its use. In addition, because forceps are being taught less in training programs, fewer and fewer physicians are being trained in the essential skills of operative vaginal delivery. This review is intended to emphasize the correct techniques and skills of vacuum-assisted vaginal delivery in an attempt to increase the success and decrease the complications associated with its use.
Key words: VACUUM-ASSISTED DELIVERIES; OPERATIVE VAGINAL DELIVERY COMPLICATIONS;
BIRTH INJURIES

INTRODUCTION James Young Simpson of Edinburgh is frequently recognized as one of the pioneer physicians to utilize the principle of the modern vacuum device to facilitate a vaginal delivery. However, it was not until the 1950s when Malmstrom introduced a stainless steel metal cup, that the practice of operative vaginal delivery was revolutionized. The acceptance of the vacuum device as a safe alternative to forceps was delayed in the USA as compared to European countries, but as of 1992, the rate of vacuum delivery surpassed the rate of forceps delivery in the USA1. However, over the past two decades, the overall rate of operative vaginal delivery has been decreasing, while the rate of Cesarean sections has been increasing. Nevertheless, about 10% of all births in the USA each year are forceps- or vacuum-assisted deliveries1. The overall decrease in operative vaginal delivery appears to stem from fear of litigation, patient resistance and diminishing numbers of experienced physicians. As a result, there are fewer and fewer opportunities for younger physicians to be trained. Inadequate training then leads to increased complications, which leads to more fear and patient resistance and so on it becomes an unfortunate cycle of diminishing returns. There are fewer physicians willing to teach the art of forceps-assisted delivery, thus the brunt of the operative vaginal delivery is being placed on the vacuum device. However, the perception that the vacuum device is easier to use and requires less skill, leads to less concentrated efforts in learning the essential skills for vacuum delivery, leading to poor technique and less than optimal neonatal and maternal outcomes. Thus, it is important to undertake a full exploration of the literature on vacuum-assisted delivery to incorporate the techniques and guidelines that lead to the greatest success and best outcomes for both mother and baby. CLASSIFICATION OF DELIVERIES In February 1988, revisions were made to the forceps classication system of the American College of Obstetricians and Gynecologists (ACOG) (Table 1). The revisions were made to correct the apparent shortcomings of the previous system, reported as the outlet class being dened too narrowly and midforceps class dened too broadly. The revisions instituted three major changes: expansion of the category of outlet deliveries to allow

Correspondence: Dr R. W. McQuivey, Clinical Innovations, Inc., 747 West 4170 South, Murray, UT 84123, USA (801) 268-8200 (wk) (801) 266-7373 (fax) rwm@clinicalinnovations.com
# 2004 Parthenon Publishing. A member of the Taylor & Francis Group DOI: 10.1080/1476-7050400001706

Received 15-04-04 Revised 21-06-04 Accepted 28-06-04

Vacuum-assisted delivery

McQuivey

Table 1 ACOGs 1988 revised classication of assisted vaginal deliveries according to station and rotation Type of procedure Outlet Classication Scalp is visible at the introitus without separating the labia Fetal skull has reached the pelvic oor Sagittal suture is in anteroposterior diameter or right or left occiput anterior or posterior position Fetal head is at or on perineum Rotation does not exceed 45 degrees Leading point of fetal skull is at station 5 + 2 cm, and not on the pelvic oor Rotation 4 45 degrees (left or right occiput anterior to occiput anterior, or left or right occiput posterior to occiput posterior) Rotation 4 45 degrees Station above + 2 cm but head engaged Not included in classication

above the pubic symphysis, regardless of station according to the vaginal examination, the fetus should be regarded as unengaged and an operative delivery should be avoided. PATIENT SELECTION The selection of candidates for vacuum-assisted vaginal delivery is of the utmost importance. Even when a valid indication for expediting the birth of the fetus exists, a number of other factors that may inuence the outcome must be assessed and evaluated prior to attempting the assisted delivery. These factors can be grouped into four general categories: the history of the pregnancy and labor; the mothers condition; the fetuss condition; and the operators experience/skills. It is important to be aware of any risk factors associated with the pregnancy that may affect the progress of labor and a potential operative delivery (e.g. maternal bleeding disorder, history of cardiopulmonary disease, diabetes). In addition, the progress of the rst and second stages of labor should be assessed. Recently, the accepted duration of the second stage of labor has been extended, owing to the increasing use of regional anesthesia and continuous fetal monitoring. It is important to realize that the more abnormal the labor process, the higher the rate of complications, regardless of the birthing technique4,5. Second, it is important to assess the mothers condition, and her willingness and ability to be a co-operative partner in the procedure. Maternal effort is required in the vacuum delivery. The greater the maternal expulsive efforts, the less traction force will be required to assist the delivery, thus reducing the incidence of complications. In addition to encouraging maternal efforts, the utilization of oxytocin, as necessary, is of the utmost importance. The operator should take full advantage of the contractile strength of the uterus that is available when conducting the delivery. Third, assessment of the fetus includes an evaluation of the fetal heart-rate (FHR) tracing, as well as an estimated fetal weight (EFW). An assisted delivery in the face of a non-reassuring FHR tracing may be more challenging than one accompanied by a reassuring FHR tracing, because of the possible underlying fetal compromise, as well as the speed in which it is carried out. Although it is not an exact science, estimating the fetal weight remains important. A clearly marked EFW in the patients chart is essential while practicing in todays increasingly litigious society. Finally, to achieve optimal results with the vacuum delivery, the operators level of experience should be appropriately matched to the clinical requirements and potential risks of the procedure. This area is rarely emphasized when reviewing the outcomes of operative vaginal deliveries, but has a signicant impact on the results. Therefore, the goal of appropriately training and educating practitioners should be at the forefront of future efforts.

Low

Mid High

American College of Obstetricians and Gynecologists. ACOG Committee Opinion 71. Washington, DC: ACOG, 1988

limited rotation from the anteroposterior position; restriction of the mid-level to those deliveries above the + 2 cm station; and the creation of an intermediate classication of low forceps2. Although the original focus of the ACOG classication system was for forceps deliveries, it is important to realize that the same classication should be utilized in operative vaginal delivery. The denitions were created to stratify the risk of maternal and neonatal morbidity in operative vaginal deliveries (forceps- and vacuum-assisted delivery), and thus, should be utilized for both techniques. The revised system recommended using the level of the leading bony point of the fetal head in centimeters at or below the level of the maternal ischial spines to dene the station (05 cm), instead of the previously used method of dividing the birth canal into thirds (03 + ). In this system, engagement implies that the biparietal diameter (BPD) has passed through the pelvic inlet and that the leading point of the fetal head is at least at the level of the ischial spines (0 station). However, the vaginal examination can be misleading in infants who have signicant molding. Thus, in addition to the vaginal assessment of station, one should perform an abdominal examination as dened by Crichton in 19743. This method allows the practitioner to evaluate the amount of fetal head divided into fths that is palpable above the pelvic brim. No more than twofths of an unmolded fetal head should be palpated above the pelvic brim once the occiput has reached the ischial spines. If more than two-fths of the fetal head is palpable
172
Journal of MaternalFetal and Neonatal Medicine

Vacuum-assisted delivery

McQuivey

INDICATIONS The following are indications for vacuum-assisted delivery, but it is important to keep in mind that these should be accompanied by full cervical dilatation and the fetal head being engaged: prolonged second stage of labor; suspicion of immediate or potential fetal compromise; and shortening the second stage of labor for maternal benet6. CONTRAINDICATIONS Knowing the contraindications to the procedure is just as important as having a valid indication. Contraindications include prematurity, generally dened as 36 weeks, although there are a few papers reporting the use of the vacuum on more premature infants with success7,8. However, the evidence is lacking to establish a denitive gestational age threshold at this point. Additional contraindications include a live fetus known to have a bone demineralization or bleeding disorder, the fetal head not engaged in the maternal pelvis, incomplete cervical dilatation, suspected cephalopelvic disproportion (dened as severe or increasing molding of the fetal head and a high presenting part failing to descend despite strong uterine contractions) and unknown position of the fetal head. Practitioners should discard the oft utilized erroneous notion that the vacuum device should be used, instead of forceps, when the position of the fetal head is unknown.9 Finally, one should be wary of delivering a severely compromised fetus as a rescue procedure, because such infants may have already sustained an injury, which could then be blamed on the vacuum device or the vacuum operator. The utilization of a fetal scalp electrode (FSE) or fetal scalp blood sampling are no longer considered contraindications to the use of the vacuum. Early literature described bleeding from the scalp and cephalohematoma formation after using these techniques to evaluate the infant10. However, the more recent literature has not conrmed these associated complications11,12,13. THE FLEXION POINT In 1954, Rydberg reported that the fetal head was completely exed when the mentovertical diameter pointed in the direction of the pelvic axis and that this diameter joined the sagittal suture 3 cm in front of the posterior fontanelle14.This exed position promotes synclitism and exion of the fetal head, presenting the optimal diameters of the fetal head to the maternal pelvis. In 1976, Bird began stressing the importance of achieving a exing median application to promote safer and more successful vacuum deliveries15. He used this concept to modify the original Malmstrom vacuum cup and showed greater

success delivering the malpositioned (occiput posterior and occiput transverse) infants with the vacuum. In 1990, Vacca coined the phrase exion point to describe the site on the fetal scalp over which the center of the vacuum cup should be placed to achieve a exing median application16,17. Vacca used Rydbergs description and Birds concepts to simplify and co-ordinate efforts in vacuum delivery and to provide a vacuum equivalent to Dennens pivot point for the forceps. Thus, the exion point should be the center point of the vacuum cup when it is attached to the fetal head and is located 3 cm anterior to the posterior fontanelle along the sagittal suture. MATERNAL COMPLICATIONS The literature has made clear that, compared to forceps, vacuum-assisted delivery causes less maternal genital tract trauma, less blood loss, and requires less maternal analgesia. Recently, obstetric morbidity relating to postpartum pelvic oor damage and fecal incontinence has gained increasing attention. Fear of fecal and urinary incontinence is frequently quoted when women request an elective Cesarean section. In 2003, in a prospective, randomized clinical trial, Fitzpatrick and colleagues18, compared differences in anal sphincter function following vacuum- and forceps-assisted deliveries. Their results showed that, in the short term, signicantly more women complained of altered continence following forceps delivery when compared with vacuum delivery. These ndings were also echoed by Sultan and co-workers19, who found that 80% of primiparous women delivered by forceps developed sub-clinical sphincter defects, while no defects were identied after vacuum extraction. Thus, there should be little doubt remaining that vacuum assisted delivery is associated with fewer short-term injuries to the maternal perineum compared to forceps delivery. Additional longterm follow-up studies need to be completed and the role of labor itself needs to be evaluated before it is decided that forceps should go the way of the breech delivery. NEONATAL COMPLICATIONS The literature comparing the effects of the vacuum and forceps on the neonate has been somewhat mixed. However, it has consistently been reported that the vacuum is associated with a higher rate of cephalohematomas and neonatal jaundice20,21. In addition, the original reports of acute scalp injuries and later serious cranial injuries and deaths associated with the use of the vacuum, delayed its adoption in the USA. Several attempts were made to reduce these complications, but the root of the problem correct cup placement and technique continued to be lost in the background. In an attempt to decrease fetal scalp injuries, manufacturers began making
173
Journal of MaternalFetal and Neonatal Medicine

Vacuum-assisted delivery

McQuivey

vacuum cups with silicone or plastic material, instead of the cold, hard metal of the original Malmstrom cups. The softer material was felt to be more esthetically pleasing and led practitioners to believe that it would decrease the complications associated with operative vaginal delivery22, although the randomized trials since then have been less promising23. In 1998, the US Food and Drug Administration (FDA) issued a public health advisory to all practitioners, urging caution when using the vacuum device, as a result of an increase in the morbidity and mortality reported to the FDA. Proponents of the vacuum were quick to blame the increase in usage from 3.5% of all deliveries to 5.9% from 1989 to 1995 however, the FDA felt obligated to issue the advisory because of what they believed were avoidable complications24. Scalp effects Nearly all infants delivered with the assistance of a vacuum will exhibit visible scalp effects to a varying degree at the site of cup attachment. However, the majority are cosmetic, transient and of no clinical signicance to the infant, but may cause considerable anxiety to the unprepared parent. The more signicant injuries are, more often than not, related to misplacement of the cup, excessive or poorly directed traction, or cephalopelvic disproportion. Chignon The chignon or articial caput succedaneum, is caused by a collection of interstitial uid and micro-hemorrhages that occur under the cup site. This temporary anatomical defect keeps the vacuum cup more rmly attached to the fetal scalp. The fetal scalp lls the internal diameter of the vacuum cup in a key-in-lock type fashion. It is less pronounced when using soft cups versus rigid, and mushroom-shaped cups, and is an effect not seen with forceps. It is created by the pressure gradient that is established between the vacuum (sub-atmospheric pressure) and the mean arterial pressure of the neonate. The chignon is most obvious immediately following removal of the cup from the scalp, but typically resolves within 1218 h and importantly has no long-term clinical signicance. Scalp abrasions and lacerations The reported incidence of scalp abrasions and lacerations ranges from 1 to 82%25,26; however, most studies report an overall occurrence rate of approximately 10% for lacerations, the majority of which are supercial and of a minor degree. The wide range of reported incidences appears to be due to inaccurate reporting and a lack of accepted denitions that differentiate scalp lacerations,
174
Journal of MaternalFetal and Neonatal Medicine

abrasions and other effects. Clearly outlined denitions of scalp injuries would be helpful in further evaluating the safety of vacuum-assisted delivery. More difcult vacuum deliveries, such as in occiput posterior and transverse positioned infants as well as infants at midstation, predispose to increased scalp injuries. However, the majority can be avoided with correct cup placement, avoidance of prolonged or misguided traction, and avoidance of cup detachments (pop-offs). Retinal hemorrhage The literature has shown that retinal hemorrhages occur more commonly in infants delivered by vacuum, compared to normal spontaneous deliveries or forceps-assisted deliveries27,28. However, the hemorrhage is transient with no apparent long-term developmental or any ophthalmological consequences29. Neonatal jaundice Like retinal hemorrhages, neonatal jaundice has been reported to occur more commonly with vacuum-assisted delivery than forceps or normal spontaneous vaginal deliveries. Nonetheless, it is important to remember that there is no difference between the two operative vaginal delivery techniques when comparing signicant jaundice (i.e. hyperbilirubinemia) requiring phototherapy.30 Cephalohematoma A cephalohematoma is a collection of serosanguinous uid that accumulates under the periosteum of the skull bones, resulting from compression of the presenting part of the fetal head. It is clear that more cephalohematomas occur with operative vaginal delivery than forceps or normal spontaneous vaginal deliveries. The reported incidence of cephalohematomas ranges between 1 and 25%, with an average of approximately 12%12,23. However, the clinical signicance of the cephalohematoma is minimal. This is because the bleed is conned within the boundaries of the periosteum, limiting the amount of blood that can accumulate in this potential space. Clinically, the edema associated with the cephalohematoma will not cross the suture lines and thus can be differentiated from the more serious complication, the subgaleal hemorrhage. Typically, cephalohematomas resolve within several days, but large ones may take up to several weeks, with no specic therapy required31. Subgaleal hemorrhage On the other hand, a subgaleal hemorrhage is a potentially life-threatening complication of vacuum deliveries and

Vacuum-assisted delivery

McQuivey

must be clinically differentiated from a cephalohematoma. A subgaleal hemorrhage is formed by ruptured emissary veins that bleed into the potential space between the scalp aponeurosis, or galea aponeurotica, and the periosteum of the cranial bones. Unlike the cephalohematoma, suture lines do not limit this potential space, thus infants can lose up to 80% of their blood volume into this potential space. Infants may present with symptoms of hypovolemic shock, in addition to the diffuse and dependent swelling of the cranium. The reported incidence of subgaleal hemorrhages is slightly less than 1%23, but the mortality rate associated with this lesion approaches 25%32, if untreated. Therefore, it is important that every infant who undergoes a vacuumassisted delivery receives directed attention to the scalp at periodic intervals to detect evidence of diffuse swelling. This means that the cap placed on most of the neonates born in the USA, to retain body heat, must be removed periodically. In addition, the delivering physician should notify the care-provider of the neonate that a vacuum was used to perform the delivery, so that appropriate follow-up can be made. It should be remembered that subgaleal hemorrhages may not become clinically evident for hours to several days after the delivery32,33. WHICH CUP AND WHY? There are two general categories of vacuum cup: the rigid, mushroom-shaped cups patterned after the original Malmstrom cup; and the soft, bell- or trumpet-shaped cups (Table 2). The original metal cups were reprimanded for being too cumbersome to assemble and too insulting to the fetal scalp. The soft, bell- or trumpet-shaped cups were criticized for being more likely to fail to achieve vaginal delivery and more likely to become detached (pop-off)23. The soft cups were touted for causing less fetal and maternal trauma, but the follow-up studies comparing the two types of cup showed that the soft cups may reduce the number of transient or supercial scalp effects, but they did not change the rate of serious complications (e.g. subgaleal hemorrhage) and there were no differences in Apgar scores, cord pH, neurological outcomes, or maternal genital tract trauma23. The majority of fetal complications associated with the use of vacuums are caused by misplacement of the cup, not unlike the fetal complications associated with the use of forceps. Thus, it appears that the material of the cup is less important, as long as it allows the operator to place it over the exion point. Although the soft cups have generally been better received in the USA, it is important to realize that the combined and centrally located vacuum port and traction stem limits their maneuverability. The operator is unable to move the soft cup more than 13 cm laterally or posteriorly, because the stem and height of the cup comes

into contact with the maternal tissue. When the infant is at the outlet in an occiput-anterior (OA) position with minimal to no asynclitism, the exion point lies near the introitus and is accessible by any cup on the market, including the soft cups. However, when there is signicant asynclitism, the infant is in the low to mid-pelvis, or is malpositioned (occiput-posterior (OP) or occiput-transverse (OT)), there are only a few select cups on the market that can be properly placed in a exing median application. Two companies have produced what appear to be the plastic equivalents of the Bird posterior cup (Omni-cup, Kiwi, Clinical Innovations, Murray, UT; M-select cup, Mityvac, Cooper Surgical, Trumbull, CT, USA). Like the Bird posterior cup, these cups can be used in all fetal positions because of their low prole and innovative design, and allow greater maneuverability within the birth canal. METHOD OF TRACTION Not unlike traction applied with forceps, correct traction in the axis of the pelvis should be followed while conducting a vacuum delivery. The traction should be applied at the onset of a contraction and maintained smoothly for the duration thereof, with maternal expulsive efforts. Traction efforts should be discontinued between contractions, or if an audible hiss is heard, representing a loss of vacuum. Constant encouragement should be offered to the mother to bear down during the contraction. In addition, the practitioner should inform her of the progress

Table 2 Classication and use of vacuum delivery cups Soft cups Indicated for outlet . Kiwi ProCup and Kiwi and low OA 5 458 assisted OmniCup deliveries . Silc, Gentle Vac, and Secure Cups . Silastic, Reusable and VacU-Nate cups . Standard MityVac and Soft Touch cups Rigid anterior cups . M-Style MityVac cup Indicated for outlet and low . Flex cup OA 5 458 assisted deliveries . Malmstrom, Bird and ONeil cups Rigid posterior cups . Kiwi OmniCup Indicated for OA 4 458, OP . M-Select Mityvac cup and OT assisted deliveries . Bird and ONeil Posterior cups OA, occiput-anterior; OP, occiput-posterior; OT, occiput-transverse (adapted from Vacca A. Vacuum assisted delivery; improving patient outcomes and protecting yourself against litigation. Suppl OBG Manag 2004:S112 with permission) 175
Journal of MaternalFetal and Neonatal Medicine

Vacuum-assisted delivery

McQuivey

being made. Conscious effort should be made to avoid any rotating or side-to-side movements, which only increase the incidence of the so-called cookie-cutter lacerations and sudden cup detachments. In an attempt to encourage correct pelvic-axis traction, a kneeling or seated position is recommended. This position encourages the operator to apply traction in a downward direction and achieve axis traction and progressive descent of the presenting part by maintaining the exion point on or just behind the axis of the pelvis. Vacca states: this position is particularly important when vacuum extraction is attempted before the fetal scalp is visible at the introitus. For low extractions when the scalp is visible or when the head has descended to the outlet, the direction of traction will change progressively in an upward direction until the standing position becomes more appropriate34. It is important to recall that the pelvis and birth canal are situated like a stovetop pipe the superior portion sits nearly 908 in relation to the inferior portion and this direction should be followed when performing a vacuum delivery. One of the most common mistakes in vacuum deliveries is to direct the traction anteriorly, too soon. This tends to occur because the cup is positioned approximately 6 cm anterior to the BPD (the largest diameter of the fetal head) and once the cup is seen at the introitus, practitioners begin upward traction. Unfortunately, this force is absorbed by the pubic ramus of the mother because the largest diameter, the BPD, has not cleared the maternal pelvis. Thus, the downward traction should be continued slightly longer than anticipated, until the BPD has cleared the maternal pelvis. With the pulling hand, the operator should maintain a nger-tip position, holding the traction bar in the slightly exed distal interphalangeal joints with the palm of the hand opened and facing upwards. Sufcient traction for the delivery of the infant can be generated in most cases simply by exing the ngers that are holding the bar. It is also good practice for the operator to tuck the elbow into the side of the body to help prevent pulling more forcefully with the arm35. In the past, a three-pull rule has generally been promoted for conducting operative vaginal deliveries. This was implemented to prevent an excessive number of tractions applied to the fetal scalp and in hopes of reducing complications. However, what is the rush with assisted deliveries if the fetus and mother are tolerating the procedure and progress is being made? In their description of the active management of labor, ODriscoll and colleagues divided the second stage of labor into two phases35. The rst is the descent phase, in which the fetus traverses through the birth canal to the pelvic oor. The second is the perineal phase, which is from the pelvic oor to the delivery of the fetus. Utilizing this concept, attempting to decrease the incidence of pelvic oor injury
176
Journal of MaternalFetal and Neonatal Medicine

and acknowledging the increase in regional anesthesia, Vacca suggested a three-plus-three-pull rule when conducting a vacuum-assisted delivery34. Vacca maintains that three pulls for the descent phase and three pulls for the perineal phase are acceptable provided that some progress is observed with each pull and that the traction force is not excessive. This method allows the perineum to accommodate the fetal head and may avoid perineal tears or episiotomy extensions. AUTOROTATION It is often stated that one cannot rotate an infant with the vacuum. In fact, many have been taught that the only way to deliver an OP (or OT) infant is to pull them out directly OP or rotate them with specialized forceps (e.g. Kiellands). However, it has been shown that if the vacuum cup is placed in a exing median application 3 cm anterior to the posterior fontanelle along the sagittal suture 90% or more of these infants will rotate and deliver in an OA position with normal axis traction15,34. This apparent anomaly is made possible by encouraging the optimal diameters of the fetal head to align with the maternal pelvis. It is important to remember that during the process of normal labor the majority of infants enter the pelvis in OP to OT positions, yet 90% of infants are delivered in an OA position. This occurs through the well-known cardinal movements of labor one of which is internal rotation. Internal rotation occurs during the normal process of labor rotating the fetus from an OT position to an OA position (90% of the time) and an OP position (about 10% of the time). This movement encourages the smallest diameter of the infants head to present to the maternal pelvis and allow passage with the least amount of force. This process should also take place when assisting the infant with the vacuum the desire is to realign the asynclitic and/or deexed fetal head with the maternal pelvis. This encourages the optimal diameters of the fetal head to traverse the birth canal with the least amount of force. Thus, the rotation that occurs is an autorotation process, not a forced one. No attempt should be made to physically rotate the cup on the infants head because this leads to a greater propensity for lacerations and cup detachments. KNOWING WHEN TO ABANDON THE PROCEDURE Although established rules are rarely absolute in the world of medicine, it is important to be aware of guidelines associated with abandoning a vacuum procedure, to decrease the incidence of serious injuries. This is not to imply that all injuries can be avoided; in fact, some injuries may occur prior to the cup being placed4,5. However, it is important to realize that using correct techniques and

Vacuum-assisted delivery

McQuivey

being willing to abandon the procedure when normal progress is not achieved, can signicantly reduce the incidence and severity of injuries. Dening normal progress is the difcult task, but the following guidelines, which have been created after an extensive literature review, should function as a template for clinicians performing vacuum-assisted deliveries. An adequately trained operator should abort the procedure if no descent of the fetal scalp and skull occur after two tractions or the delivery is not achieved after three-plus-three tractions, as described above. It is important to realize that, when descent does not occur, it rarely is due to lack of traction force the majority of successful vacuum deliveries require 25 lb (11.25 kg) or less.34 In fact, the main cause of lack of descent with traction is malplacement of the cup (a paramedian and/or deexing application), poorly directed traction or cephalopelvic disproportion. Cup detachments or pop-offs were once thought of as a safety mechanism of the vacuum device. This notion originated from earlier forceps studies by Wylie revealing that up to 75 lb (33.75 kg) of force could be applied to the infants head during a forceps delivery36. However, the vacuum detaches from the infants scalp long before that amount of force can be applied to the infants head. In laboratory studies, the vacuum detached at a maximum force of approximately 40 lb (18 kg)37, making it appear safer than forceps. Therefore, practitioners began thinking that the detachment or pop-off prevented them from applying excessive force to the infants scalp. What they did not realize was that the sudden loss of pressure that occurs during the detachment is a predisposing factor for many of the major complications (subgaleal and intracranial hemorrhages)27,38. In addition, as the rate of pop-offs increases, so does the rate of scalp abrasions, lacerations and edema15,26. If the traction force required to overcome resistance to descent is greater than the adhesive force of the cup, detachment will occur, regardless of how well the cup is designed or where the cup is placed. For this reason, it is important to minimize the traction force and the number of detachments. Other possible causes of cup detachment that should be considered include poor axis traction, faulty equipment or inadequate vacuum pressure and large caput succedaneums (with soft cups). If one detachment occurs, a thorough evaluation of cup placement and whether or not maternal tissue may have been trapped under the cup should take place prior to considering a second application. It should be remembered that correct cup placement and traction directed along the axis of the pelvis should prevent the majority of detachments. Arbitrary time limits ranging from 15 min15 to 45 min39 have been suggested for vacuum delivery as a protective measure for the fetus against prolonged or excessive

traction. However, recent literature has demonstrated that, with efcient uterine contractions and good maternal expulsive efforts, almost all vacuum-assisted deliveries can be completed within 15 min34 and, if one reaches the 20min time limit, the procedure should be abandoned unless delivery is imminent. Finally, one should be wary of attempting forceps delivery after a failed vacuum delivery. The literature has shown that sequential use of instrumental delivery carries a signicantly higher neonatal morbidity than when a single instrument is used40,41. The ACOG cautions against this technique, but does not list it as an absolute contraindication6. The technique has an increased relative risk and thus should rarely be used. It should be limited to cases at the outlet when forceps are considered safe and vacuum failed, owing to inexperience or technical failure. Most importantly, one should always be willing to abandon the procedure and move directly to cesarean section without hesitation. CONCLUSIONS The future of vacuum-assisted deliveries will depend on the willingness of practitioners to be trained and to train those who come after them. The use of simulation models, like those being used to train physicians in the management of shoulder dystocia42, should be implemented in operative delivery training efforts as well. Vacuumassisted delivery is a good alternative to forceps or a Cesarean section in stalled labor, when used correctly. Placement of the cup over the exion point is key to presenting the smallest diameter of the fetal head to the maternal pelvis, thus reducing the amount of force required to conduct the delivery. Correct cup selection is also important, especially in the malrotated or asynclitic infants. One should be encouraged to utilize a maneuverable vacuum cup with a low prole that allows correct cup placement (exing median) in nearly all infants. Axis traction in line with the maternal pelvis is also of the utmost importance and should be stressed when training new physicians. Finally, being willing to abandon the procedure if one of the noted limits is reached, should also serve as a safety measure. If these guidelines are implemented, the success rate of vacuum delivery should increase, the complications decrease, and the litigation associated with assisted deliveries should also decrease. The problems with many of the current studies are that they are retrospective, have short followup intervals and confounding factors, and often lack randomization. Therefore, further research is needed to determine the ideal method of instrumental delivery in various clinical settings, especially focusing on the longterm effects of operative vaginal deliveries on the pelvic oor.
177
Journal of MaternalFetal and Neonatal Medicine

Vacuum-assisted delivery

McQuivey

ACKNOWLEDGEMENT Thanks to Dr Aldo Vacca for his generous input and expertise in preparing this manuscript.

REFERENCES
1. Miksovsky P, Watson WJ. Obstetric vacuum extraction: state of the art in the new millennium. Obstet Gynecol Surv 2001;56:73651 2. Hagadorn-Freathy AS, Yeomans ER, Hankins GD. Validation of the 1988 ACOG Forceps Classication System. Obstet Gynecol 1991;77:35660 3. Crichton D. A reliable method of establishing the level of the fetal head in obstetrics. S Afr Med J 1974;48:7847 4. Towner D, Castro MA, Eby-Wilkens E, et al. Effect of mode of delivery in nulliparous women on neonatal intracranial injury. N Engl J Med 1999;341:170914 5. Whitby EH, Grifths PD, Rutter S, et al. Frequency and natural history of subdural hemorrhages in babies and relation to obstetric factors. Lancet 2004;363:84651 6. American College of Obstetricians and Gynecologists. ACOG Practice Bulletin No. 17, June 2000 7. Morales R, Adair CD, Sanchez-Ramos L, et al. Vacuum extraction of preterm infants with birth weights of 1500 2499 grams. J Reprod Med 1995;40:12730 8. Thomas SJ, Morgan MA, Asrat T, et al. The risk of periventricular-intraventricular hemorrhage with vacuum extraction of neonates weighing 2000 grams or less. J Perinatol 1997;17:3741 9. Gilstrap LC, Cunningham FG, VanDorsten JP. Operative Obstetrics, 2nd edn. McGraw-Hill, 2002 10. Roberts IF, Stone M. Fetal hemorrhage: complications of the vacuum extractor after fetal blood sampling. Am J Obstet Gynecol 1978;132:109 11. Vacca A. Operative vaginal delivery: clinical appraisal of a new vacuum extraction device. Aust NZ J Obstet Gynecol 2001;41:15660 12. Johanson RB, Menon BKV. Vacuum extraction versus forceps for assisted vaginal delivery (Cochrane Review). In: The Cochrane Library, Issue 4, 1999. Oxford: Update Software 13. Johanson R, Pusey J, Livera J, et al. North Staffordshire/Wigan assisted delivery trial. Br J Obstet Gynecol 1989;96:53744 14. Rydberg E. The mechanism of labour. Springeld: Charles C Tomas, 1954;180 15. Bird GC. The importance of exion in vacuum extractor delivery. Br J Obstet Gynecol 1976;83:194200 16. Vacca A. The place of the vacuum extractor in modern obstetrical practice. Fetal Medicine Review 1990;2:10322 17. Vacca A. Handbook of vacuum extraction in obstetric practice. London: Edward Arnold, 1992 18. Fitzpatrick M, Behan M, OConnell R, et al. Randomized clinical trial to assess anal sphincter function following forceps or vacuum assisted vaginal delivery. Br J Obstet Gynaecol 2003;110:4249

19. Sultan AH, Kamm MA, Bartram CI, et al. Anal sphincter trauma during instrumental delivery. Int J Gynecol Obstet 1993;43:26370 20. Johnson JH, Figueroa R, Garry D, et al. Immediate maternal and neonatal effects of forceps and vacuum-assisted deliveries. Obstet Gynecol 2004;103:51318 21. Wen SW, Liu S, Kramer MS, et al. Comparison of maternal and infant outcomes between vacuum extraction and forceps deliveries. Am J Epidemiol 2001;153:1037 22. Maryniak GM, Frank JB. Clinical assessment of Kobayashi vacuum extractor. Obstet Gynecol 1984; 64:4315 23. Johanson RB, Menon BKV. Soft versus rigid vacuum extractor cups for assisted vaginal delivery (Cochrane Review). The Cochrane Library, Issue 4, 2002. Oxford: Update Software 24. Center for Devices and Radiological Health. FDA Public Health Advisory: need for caution when using vacuum assisted delivery devices. May 21, 1998. Available at http:// www.fda.gov/cdrh/fetal598.html. Retrieved February 18, 2004 25. Hammarstrom M, Csemiczky, Belfrage P. Comparison between the conventional Malmstrom extractor and a new extractor with Silastic cup. Acta Obstet Gynecol Scand 1986;65:7912 26. Plauche ` WC. Fetal cranial injuries related to delivery with the Malmstrom vacuum extractor. Obstet Gynecol 1979;53:7507 27. Berkus MD, Ramamurthy RS, OConnor PS, et al. Cohort study of silastic obstetric vacuum cup deliveries: I. Safety of the instrument. Obstet Gynecol 1985;66:5039 28. Williams MC, Knuppel RA, OBrien WF, et al. Obstetric correlates of neonatal retinal hemorrhage. Obstet Gynecol 1993;81:68894 29. Johanson RB, Rice C, Doyle M, et al. A randomized prospective study comparing the new vacuum extractor policy with forceps delivery. Br J Obstet Gynaecol 1993;100:52430 30. Lim FTH, Holm JP, Schuitemaker NW, et al. Stepwise compared with rapid application of vacuum in Ventouse extraction procedures. Br J Obstet Gynaecol 1997;104:336 31. Dell DL, Sightler SE, Plauche WC. Soft cup vacuum extraction; a comparison of outlet delivery. Obstet Gynecol 1985;66:6248 32. Amar AP, Aryan HE, Meltzer HA, et al. Neonatal subgaleal hematoma causing brain compression: report of two cases and review of the literature. Neurosurgery 2003;52:14704 33. Smith SA, Jett PJ, Jacobson L, et al. Subgaleal hematoma: the need for increased awareness of risk. J Family Pract 1995;41:56974 34. Vacca A. Handbook of Vacuum Delivery in Obstetric Practice. Brisbane, Australia: Vacca Research, 2003 35. ODriscoll K, Meagher D, Boylan P. Active management of labor. London; Mosby Yearbook Europe, 1993 36. Wylie B. Traction in forceps deliveries. Am J Obstet Gynecol 1935;29:42533 37. Duchon MA, DeMund MA, Brown RH. Laboratory comparison of modern vacuum extractors. Obstet Gynecol 1988;71:1558 38. Teng FY, Sayre JW. Vacuum extraction: does parturition predict scalp injury? Obstet Gynecol 1997;89:2815 39. Ross MG. Vacuum delivery by soft cup extraction. Contemp Obstet/Gynecol 1994;39:4853

178
Journal of MaternalFetal and Neonatal Medicine

Vacuum-assisted delivery

McQuivey

40. Al-Kadri H, Sabr Y, Al-Saif S, et al. Failed individual and sequential instrumental vaginal delivery: contributing risk factors and maternal-neonatal complications. Acta Obstet Gynecol Scand 2003;6428 41. Gardella C, Taylor M, Benedetti T, et al. The effect of sequential use of vacuum and forceps for assisted vaginal delivery on neonatal and maternal outcomes. Am J Obstet Gynecol 2001;185:896902

42. Deering S, Poggi S, Macedonia C, et al. Improving resident competency in the management of shoulder dystocia with simulation training. Obstet Gynecol 2004;103:12248

179
Journal of MaternalFetal and Neonatal Medicine

You might also like