Professional Documents
Culture Documents
By Building
171-173
By Building
By Function
1 Water Shutoffs All water to 171/173 195 basement under unit 181 Unknown: are there shutoffs for each duplex in the duplex or just in 195? Unknown: are there separate shutoffs for each townhouse in the duplexes? Hot Water Tanks Shutoffs in unit basements 2 Gas Shutoffs Driveway side of 173 near Harvey St (pair) 3 - Electric Driveway side of 173 near Harvey St (pair) 4 Sumps and Pumps
171 has sump with a pump at the front wall, hose dumps into laundry outlet. (TBF?) 173 has sump only, on north side (water comes in at southwest corner)
5 Heating and Cooling Furnaces in basements; AC compressors outside near kitchen doors.
175
1 Water Shutoffs NOTE: Heating system water is not affected. That is a closed, separate system. All water to 175 All water to 175 Hot water to 175 195 basement under unit 181 175 furnace room 175 furnace room
Hot Water Tanks - In furnace room, leave input valves open unless working on tanks. - Shut off hot water AFTER tanks Unknown: Judy As plumber and I could not figure out how to make this work. We had to shut off all water to the building. Sprinkler System Water will cause alarms 175 175 furnace room; not connected to main water shutoff
2 Gas Shutoffs 175 South side, under Play room windows (pair) 3 - Electric All electricity to 175 175 electric room, including meters Electricity to individual apartments in furnace room, including meters 4 Sumps and Pumps Basement:
Main Barrell Sump (has pump) - Furnace Room, under floor drain; o all other pumps bring the water here, o pumps out to Big Pond drains Paint Room (has pump), back left corner, drains elec and exercise rooms Furnace Room (has pump), far right wall, just past the furnaces, not useful Hall Corner near elevator, has a pump; newest, best, electric sensor Back hall, behind the door to the back stairs NEEDS PUMP Elevator pit (must be kept dry) Furnaces in basements; AC compressors outside, east side of building. Common space heating thermometers in Dining Room, Den, Back hall, outside the tool room, in the storage hallway and in the Exercise room. Common space cooling thermometers near elevator and art/craft room.
177-179
1 - Water All water to 177/179 195 basement under unit 181 Unknown: are there shutoffs for each duplex in the duplex or just in 195? Unknown: are there separate shutoffs for each townhouse in the duplexes? Hot Water Tanks Shutoffs in unit basements 2 Gas Shutoffs Common House side of 177, near kitchen window (pair) 3 - Electric Front side of 177, near driveway (pair) 4 Sumps and Pumps
5 Heating and Cooling Furnaces in basements; AC compressors outside near kitchen doors.
195
1 Water Shutoffs NOTE: Heating system water is not affected. That is a closed, separate system. All water to 195 195 basement under unit 181 All water to 195 apartments 195 furnace room Hot water to 195 apartments 195 furnace room Hot Water Tanks - In furnace room, leave input valves open unless working on tanks. - Shut off hot water AFTER tanks Sprinkler System Water will cause alarms 195 195 furnace room; not connected to main water shutoff 2 Gas Shutoffs Street side of 195-4, near bottom of ramp (pair) 3 - Electric All electricity to 195 195 furnace room, including meters Electricity to individual apartments in furnace room, including meters 4 Sumps and Pumps
Main Barrel Sump (has pump) - Furnace Room, under floor drain; o all other pumps bring the water here, o all townhouse floor drains water comes here Furnace Room, far left wall, just past the furnaces Electrical Room Storage Areas (Starting from electrical room) o 4th Area (maybe) o 5th Area o Next to last area o No Carol o Yes Serge also electric outlet, Mef, Jane o May be others, under/behind stored stuff Drain at bottom of outside stairs.
5 Heating Only
Furnaces in basements; AC compressors outside, east side of building. Common space heating thermometers in first floor hallway and second floor guest room.
195 Townhouses
1 Water Shutoffs All water to 195 195 basement under unit 181 All water to 181,183,185,187,189 195 basement hallway, individual shutoffs with hang tags Hot Water Tanks Shutoffs in unit basements 2 Gas Shutoffs 181 Driveway side of 181, behind trash enclosure 183,185 Street side of 183 (pair) 187,189 Street side of 189 (pair) 3 - Electric Electricity to individual townhouses in furnace room, including meters 4 Sumps and Pumps
Each basement has a floor drain, connects to 195 Furnace room barrel sump - 181 has sump with a pump, connected to laundry output TBF - 183 has sump only - 185 has sump with a pump, output to Big Pond system ??? - 187 has sump only - 189 has sump only
5 Heating and Cooling Furnaces in basements; AC compressors outside near kitchen doors.
By Function
IFind the Shutoffs
1 - Water NOTE: 175/195 Heating system water is not affected. That is a closed, separate system. ONE MAIN SHUTOFF to all buildings 195 basement under unit 181 Individual Shutoffs All water to any one building 195 basement under unit 181 All water to 195 apartments 195 furnace room All water to 175 175 furnace room Hot water to 195 apartments 195 furnace room Hot water to 175 175 furnace room Water to each 195 townhouse 195 basement hallway; individual valves, labeled Unknown: are there shutoffs for each duplex in the duplex or just in 195? Unknown: are there separate shutoffs for each townhouse in the duplexes? Hot Water Tanks - In 175 furnace room, leave input valves open unless working on tanks. - In 195 furnace room, leave input valves open unless working on tanks. - In 171,173,177,178.181,183,185,187,189 unit basements Sprinkler System Water will cause alarms 195 195 furnace room; not connected to main water shutoff 175 175 furnace room; not connected to main water shutoff 2 - Gas All eleven gas shutoffs and meters are outside the buildings. There are individual shutoffs for each townhouse plus one each for 175 and 195 apartments. 171,173 - Driveway side of 173 near Harvey St (pair) 175 South side, under Play room windows (pair) 177, 179 Common House side of 177, near kitchen window (pair) 181 driveway sied of 181, behind trash enclosure 183,185 street side of 183 (pair) 187,189 street side of 189 (pair) 195 street side of 195-4, near bottom of ramp (pair) 3 - Electric All electricity to 195 195 furnace room, including meters All electricity to 175 175 electric room, including meters Electricity to individual apartments in 195 195 furnace room, including meters
Electricity to individual units in 175 175 electric room, including meters Electricity to each townhouse (195 and duplexes) townhouse basements - 195 townhouse meters are in 195 furnace room - 171,173 meters - Driveway side of 173 near Harvey St (pair) - 177,179 meters front side of 177, near driveway (pair)
II-
At the front wall, hose dumps into laundry outlet. (TBF?) Main Sump - Furnace Room, under floor drain; all other pumps bring the water here, Paint Room, back left corner Furnace Room, far right wall, just past the furnaces Hall Corner near elevator, has a pump; newest, best, electric sensor Only 185 townhouse has a pump Main Sump - Furnace Room, under floor drain; all other pumps bring the water here, Furnace Room, far left wall, just past the furnaces Electrical Room
175 Basement:
195 Basement
177-179
Back hall, behind the door to the back stairs Elevator pit (must be kept dry) Basement of 177, crawlspace under cellar stairs Each townhouse basement (in 185 there is a pump) Each townhouse has a floor drain connected to the Furnace Room barrel sump Storage Areas (Starting from electrical room) o 4th Area (maybe) o 5th Area o Next to last area
195 Townhouses
195 Basement
o No Carol o Yes Serge also electric outlet, Mef, Jane o May be others, under/behind stored stuff
III-
171,173,177,179,181,183,185,187,189,191
There are two air conditioners for 175 common space. Each system has its own thermostat. The compressors are on the east side of 175. The thermostats and heat exchangers are located as follows:
Floor 1st 1st Thermostat location Next to elevator Outside A&C room Heat Exchanger location kids room closet hall ceiling near kids room
Furnaces, boilers and pumps are all in the basement furnace room. Riser pipes carry the hot water throughout each building. The hot water is constantly circulating.