Professional Documents
Culture Documents
We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers' processes over the total life cycle of our products, and beyond.
Low voltage motors for explosive atmospheres Sizes 71 to 450, 0.25 to 1000 kW
04 General information
16
Technical specication
27
53
83
113
161
Dust ignition protection motors / Protection by enclosure Ex t IIIB/ IIIC T125 C Db/Dc
210
ABB reserves the right to change the design, technical specification and dimensions without prior notice.
211
M000701
ATEX Directives 94/9/EC (95) and 1999/92/EC (137) The ATEX Directives harmonize safety rules in line with the free trading principles of the European Community. Responsibilities are split between the manufacturers and end users. Manufacturers have to comply with the Essential Health and Safety Requirements of the Products Directive 94/9/EC, or ATEX 95; and end users must prepare an Explosion Protection Document based on risk assessments of their work places and work equipment to full the minimum requirements listed in the Worker Protection Directive 1999/92/EC or ATEX 137. ABB low voltage motors for explosive atmospheres comply fully with the ATEX Products Directive 94/9/EC. According to the regulations, low voltage motors for explosive atmospheres are exempted from the Low Voltage Directive, the EMC Directive and the Machinery Directive. IECEx System The IECEx System is a certification system which verifies compliance with IEC (International Electrotechnical Commission) standards relating to safety in explosive atmospheres. It covers equipment, service facilities and the competency of personnel. Created in September 1999, the System aims to facilitate international trade in equipment and services for use in explosive atmospheres, while maintaining the required level of safety (source: IECEx website, www.iecex.com). It is a voluntary system which provides an internationally accepted means of proving that products and services are in compliance with IEC standards. The voluntary and international aspects of the IECEx System differentiate it from certication under ATEX, for example, which is mandatory but applies only within the European Economic Area. The IECEx System comprises global certification programs for both equipment and service facilities. IECEx certification involves in addition to product tests assessment of quality control procedures and testing plans, audits of manufacturing plants, and routine on-going surveillance and inspections. In addition, IECEx has established a comprehensive set of operational documents and procedures to develop a single internationally standardized approach to Ex testing and certification. The most important document is IECEx OD02, Rules of procedure for equipment certification.
The approach includes: A standardized IECEx way of Ex Testing and Certification. There is a single set of operational procedures, and Ex test procedures are always applied in the same way. A dedicated Technical and Operational Secretariat to maintain operations. Ex test procedures are evaluated and monitored on a centralized basis.
Who is responsible for the certification work? A manufacturer needing to have equipment certified under the IECEx System can apply to an IECEx Competent Body (ExCB) in any member country. At present there are 30 IECEx member countries. The ExCB performs or coordinates the activities of certification. A quality assessment of the manufacturer is undertaken by the ExCB itself, and the auditor issues an IECEx Quality Assessment Report (QAR). Type testing of product samples is performed on behalf of the ExCB by an IECEx Assessment and Testing Laboratory (ExTL). On completion of its work the ExTLs assessment engineer prepares an IECEx Test Report (ExTR). The ExTR is then submitted to the ExCB for endorsement. Based on the QAR and ExTR, the ExCB then issues the Certificate of Conformity (CoC). The CoC provides internationally accepted verification that the equipment in question is in compliance with the relevant IEC standards. Once formally issued by the ExCB, both the ExTR and QAR are registered on the IECEx Internet site. This provides verification that an ExTR and QAR exist for the product and manufacturer. How do I know if a motor is IECEx certified? IECEx certified motors show the certification number on their rating plate, for example: IECEx LCI 05.0008. In this case LCI indicates that the IECEx certificate was issued by LCIE, an IECEx approved Certification Body in France. In addition, IECEx certificates are issued in electronic form and are publicly available on the IECEx website. They can therefore be viewed and printed by anyone with access to the Internet. See Online Certificates at www.iecex.com. IECEx certification is particularly useful in certain markets. In Australia, New Zealand, and Singapore, for example, IECEx certificates are accepted, but not all IEC certificates are accepted. Certain other countries, including Russia, China and Korea, are prepared to accept ExTRs as a basis for their
M000167
General information
own national certificates. There are also many countries that are willing to accept products covered by current IECEx certificates, even though the countries in question are not members of the IECEx Management Framework. IECEx Conformity Mark License The IECEx Conformity Mark System was introduced in 2008. IECEx Conformity Mark Licenses are issued by approved Certification Bodies in IECEx participating countries. The IECEx Conformity Mark shows that a product has been granted an IECEx Certificate of Conformity. IECEx Certification confirms that the product has the appropriate protection for use in explosive atmospheres and that it has been manufactured under systems subject to ongoing surveillance by Certification Bodies. It is recognized in all the countries participating in the IECEx System, and it also means that the product can be supplied to the market without the need for additional tests. ABB has been granted IECEx Certification for a wide range of low and high voltage motors, and these can therefore display the IECEx Conformity Mark. The hazardous area protection types provided by these motors include Flameproof Ex d, Ex de Non-sparking Ex nA Dust protection Ex t The IECEx Conformity Mark License will considerably enhance ABBs ability to market its products globally. It complements ABBs existing ATEX approval. Benefits of IECEx System for end users A significant advantage of IECEx is that vendor certificates are available for inspection on the IECEx website. End users can therefore confirm the validity of IECEx certificates at any time - which is not possible with ATEX, for example. This increases end user confidence that the motor vendor will be committed to maintaining the necessary quality systems. Under the quality based IECEx certification approach the interpretation of the standard is shared throughout the 30 participating countries and individual interpretations by Notified Bodies are not allowed. Another advantage of IECEx is that the Certificate of Conformity also covers EPL (equipment protection level) c, see table on next page. Which ABB motors and generators are IECEx certified? All M3JP/M3KP 80450 motors with protection types Ex d and Ex de, M3GP 80-450 with protection type Ex nA and M3GP 80-400 with protection type Ex t are IECEx certified. Compliance on basis of recently updated standards In complying with the ATEX 95 and ATEX 137 Directives, ABB follows the requirements of recently updated IEC and EN standards. Otherwise ABB follows the requirements of the IEC standards shown in the relevant certificates.
Main standards for explosive atmospheres: IEC/EN 60079-0 IEC/EN 60079-1 IEC/EN 60079-7 IEC/EN 60079-15 IEC/EN 60079-31 IEC/EN 60079-14 IEC/EN 60079-17 IEC/EN 60079-19 IEC 60050-426 IEC/EN 60079-10 IEC 60079-10-1 IEC 60079-10-2 Equipment - General requirements Equipment protection by flameproof enclosures d Equipment protection by increased safety e Equipment protection by type of protection n Equipment dust ignition protection by enclosure t Electrical installations design, selection and erection Electrical installations inspections and maintenance Equipment repair, overhaul and reclamation Equipment for explosive atmospheres Classification of hazardous areas (gas areas) Classification of areas - Explosive gas atmospheres Classification of areas - Combustible dust atmospheres
Equipment protection levels (EPLs) The latest revisions of the IEC and EN standards introduce the new concept of equipment protection levels, which identify products according to the ignition risk they might cause. A motor's EPL therefore indicates its inherent ignition risk, regardless of its protection type. This makes the selection of equipment for different zones easier. EPLs also enable a true risk assessment approach, where the potential consequences of a possible explosion are taken into consideration. Please refer to the table on the next page for more information about EPLs and EPL markings. All ABB's cast iron motors for explosive atmospheres, have already been certified according to the EPL standards.
Explosive atmospheres
M000168
There are systems in place worldwide to classify explosive atmospheres by zones, according to the risk posed by explosive gas (G) or dust (D).
Zone 2 (G) / 22 (D) Abnormal condition Presence of explosive atmosphere only by accident, but not during normal duty Equipment protection level c required Zone 1 (G) / 21 (D) Occasionally Incidental presence of explosive atmosphere during normal duty Equipment protection level b required
Gb Gb Gb Db
Zone 0 (G) / 20 (D) Continuously Permanent presence of explosive atmosphere Equipment protection level a required
Ex nA II... Ex t III...
Gc Dc
Standard IEC 60079-0 EN 60079-0 Group I (Mines) II (Gas) Gc III (Dust) Da Db Dc enhanced very high high enhanced EPL Ma Mb Ga Gb Protection level very high high very high high
NA NA Ex d/Ex de Ex p, Ex e Ex nA NA Ex tb IP 65 Ex tc IP 65/IP 55
II (Surface)
3G 1D 2D 3D
M000176
M000169
Classication
Gas classification
Temperature class T1 T2 T3 T4 T5 T6 Ignition temp. of gas/ vapor C > 450 > 300 < 450 > 200 < 300 > 135 < 200 > 100 < 135 > 85 < 100 Max. permitted temp. of equipment C 450 300 200 135 100 85 Hydrogen Ethanol Hydrogen sulde Diethyl ether Carbon disulde IIC IIB Gas examples
Gas subdivision
IIA ~120 gases and vapors, e.g. butane / petroleum / propane ~30 gases and vapors, e.g. ethylene / dimethyl ether / coke oven gas three gases: hydrogen H2/acetylene C2H 2carbon disulfide CS2
CE marking
0081
II 2G
Ex d IIB T4 Gb
Protection type Ex d = flameproof Equipment group IIB for gas group B Temperature class T4 = max. permitted 135 C Equipment protection level = level b for gas
Identification of the notified body responsible for the approval. 0081 is the identification number of LCIE The European Commission mark for Ex products Equipment group: II for surface industry Equipment category: 2G for gas environment demanding a high level of protection
Ex d IIB T4 Gb
Protection type Ex d = flameproof Equipment group IIB for gas group B Temperature class T4 = max. permitted 135 C Equipment protection level = level b for gas
Selection of products for explosive atmospheres EN Standard and ATEX Directive for gas environments
EN 60079-0: General requirements
EN 60079-1
Flameproof enclosure
EN 60079-7
Increased safety
EN 60079-15
Non-sparking
Category 2G
Category 2G
Category 3G
...
II 2G
...
II 2G
II 3G
Ex d IIB T4 Gb
Ex e IIC T3 Gb
Ex nA IIC T3 Gc
Zone 1
Zone 1
Zone 2
M000170a
Work on accessories of enclosure componenets is only permitted using prescribed tools. Cable entries must meet the requirements of this type of protection. The temperature of the motor's external enclosure shall not exceed the self-ignition temperature of the explosive atmosphere of the installation area during operation. For this reason, rated output depends on this rated maximum temperature for the area in question. No motor device outside the flameproof enclosure (e.g., ventilator) shall be a potential source of sparks, arcs or dangerous overheating. Variants combining two types of protection usually combine d and e protection. The motor is designed with an Ex d flameproof enclosure, while the terminal box features Ex e increased safety protection. Such design combines the superior safety degree of the d type of protection with the high electrical connection requirements of increased safety motors. Alleinschutz thermistors as sole protection (optional) Flameproof motors from ABB have been designed to use thermistors as the sole method of protection against overload. This construction, Alleinschutz, is available as an option, see variant codes. Alleinschutz refers to the protection of a flameproof motor by a protective device which is triggered by thermistors. The thermistors and relays will switch off the motor in case of overheating before the temperature of the motor's external enclosure exceeds the temperature marking stamped on the rating plate. Each motor ordered with thermistors as sole protection will be tested, with locked rotor, up to the point where the thermistors trigger the relay to turn off the motor. At the triggering temperature, the motor has to be within the certified temperature class limit. Only approved relays can be used for Alleinschutz. Please note that sizes 315 to 450 require special technical solutions, consult ABB.
Dual certification Ex d/de motors can also be used for Dust/Ex t applications in zone 21. The following combinations are possible: Ex tb IIIB T125 C Db, IP 65 for zone 21 + Ex d/de IIB/ C T3 Gb Ex tb IIIC T125 C Db, IP 65 for zone 21 + Ex d/de IIB/ C T3 Gb
These features are possible due to the IP protection. The ingress of dust is prevented and thus only the outside surface temperature class is important for both applications; T4 (=135 C) for gas and T125 C for dust.
Temperature rise limits under normal operating conditions The expected electrical lifespan of a motor depends on its temperature rise for a given insulation class, and on the motor winding temperature, during operation, which is not homogeneous due to the appearance of hot spots. For these reasons, a safety margin of 10 K is allowed between the winding's temperature rise at rated output, as measured by the change of resistance method, and the maximum temperature rise permitted by the winding insulation class.
M000173
Figure 1. O = Temperature 0 C A = Max. ambient temperature, reference 40 C B = Temperature at rated load and under worst voltage conditions C = Max temperature as permitted by the insul. class D = Max limit temperature as set by the nature of the potentially explosive atmosphere E = Temperature-rise curve of motor at rated output and under worst voltage conditions F = Temp. rise curve under stalled rotor conditions tE = Stalled rotor time
M000172
Non-sparking design, Ex nA
The use of this type of protection is allowed in hazardous areas corresponding to zone 2. The design is known as nonsparking because the motor must be designed in such a way that no sparks can occur in any conditions, when used within the ratings specied by the manufacturer, and that no excessive temperatures occur under normal operating conditions, which excludes thermal requirements due to starting or accidental stalling. Ex nA motors are certied according to the ATEX 95 Directive with a voluntary type examination certicate, and according to the IEC Ex System with a normal certicate. ABB also provides self-certied non-sparking motors, with a manufacturer Declaration of Conformity. Dual certication Ex nA motors with a cast iron frame can also be used for Dust/ Ex t applications in zone 22. The following combinations are possible: Ex tc IIIB T125 C Dc, IP 55 for zone 22 + Ex nA IIC T3 Ex tc IIIC T125 C Dc, IP 65 for zone 22 + Ex nA IIC T3
Temperature rise limits during short circuit under accidental stalling conditions Should the machine stall while in operation, a shortcircuit current nearly equal to the starting current will develop, and stator and rotor winding temperatures will rise rapidly (see Figure 1). To prevent this temperature value from exceeding the maximum limit temperature as set by the nature of the potentially explosive atmosphere (D in Figure 1), protection devices must trip within a specified time (tE). This tripping time depends on the short-circuit current level or the shortcircuit current to rated current ratio (IA/IN). Figures 2 and 3 show, for commonly used protection devices, the limiting ratio between short-circuit current inrush IA/I N and rotor stalling time tE, according to the EN and IEC standards and VIK specification. VIK is an industry specification originating in Germany. This type of protection is inappropriate for commutator machines or brake-motors which, by principle, are capable of producing arcs, sparks or hot spots.
M000174
These features are possible due to the IP protection. Gases penetrate this protection, and thus the inside surface temperature class is T3 (200 C). The ingress of dust, however, is prevented and dust determines the outside surface temperature class: T125C.
The alternative to testing and certification involves, in the majority of cases, equipping the motor with provision for pre-start ventilation. This means investing in a higher capacity air compressor, piping, and a ventilation control unit. It also requires an additional operation pre-start ventilation every time the motor is started. Benets of the ABB approach therefore include reduced initial capital expenditure, lower operating costs, and faster starting. Reliability is improved as no additional components are required. Most importantly, ABBs certied motors offer proven safety. ABBs approach to meeting the new requirements Following a program of gas environment tests in which all rotor and stator tests were passed, ABB has secured certification for its low voltage cast iron motors for explosive atmospheres with aluminum die cast rotor.
Certification: Ex tb IIIB/C T...C Db (for zone 21) motors are certified according to ATEX with an EC type examination certificate and according to the IEC Ex System. Ex tc IIIB/C T...C Dc (for zone 22) motors are certified according to ATEX with a voluntary type examination certificate and according to the IEC Ex System.
Dust classification
TCL (cloud) C Food/Feeder industry Barley, corn Sugar Wood Charcoal Hard coal PVC Synth. rubber Sulfur 380 350 330 520 460 450 470 240 280 430 280 230 240 330 220 250 205 233 205 195 165 255 145 160 Wheat 350 T5mm (layer) C 270 Surface temperature provided that dust layer below 5 mm 195
Dust subdivisions
IIIA IIIB IIIC combustible yings non-conductive dust conductive dust
Natural materials
Chemicals
CE marking
0081
II 2 D
Ex tc IIIC T125 C Dc
Protection by enclosure Equipment group IIIC for conductive dust Temperature class Equipment protection level = level c for dust
Identification of the notified body responsible for the approval. 0081 is the identification number of LCIE The European Commission mark for Ex products Equipment group: II for surface industry Equipment category: 2D for dust environment demanding a high level of protection
Ex tc IIIC T125 C Dc
Protection by enclosure Equipment group IIIC for conductive dust Temperature class Equipment protection level = level c for dust
Selection of products for explosive atmospheres EN Standard and ATEX Directive for dust environments
Category 2D
Category 2D
Category 3D
Category 3D
...
II 2D
...
II 2D
II 3D
II 3D
Ex tb IIIC T125C Db
Ex tb IIIB T125C Db
Ex tc IIIC T125C Dc
Ex tc IIIB T125C Dc
IP class marking
IP65
IP65
IP65
IP55
Conductive dust
Non-conductive dust
Conductive dust
Non-conductive dust
Environment
Zone 21
Zone 21
Zone 22
Zone 22
M000171a
CSA Energy Efficiency Verification CSA EU MEPS EPAct, NEMA Premium NEC/UL STB GOST-K
GOST
ATEX (Europe)
Turkish MEPS
Mexican MEPS PESO PBE Brazilian Labelling Program Inmetro QAS SABS AU MEPS
IECEx (Worldwide)
M000700
IEC/EN 60034-30:2008 IEC/EN 60034-30:2008 defines three International Efficiency (IE) classes for single speed, three-phase, cage induction motors. Additionally, IEC/TS 60034-31 specifies efficiency class IE4. IE1 = Standard efficiency (EFF2 in the former European classification scheme) IE2 = High efficiency (EFF1 in the former European classification scheme and identical to EPAct in the USA for 60 Hz) IE3 = Premium efficiency (identical to NEMA Premium in the USA for 60 Hz) IE4 = Super premium, according to IEC/TS 60034-31 Efficiency levels defined in IEC/EN 60034-30 are based on test methods specified in IEC/EN 60034-2-1:2007. Compared to the former European efficiency classes defined by the CEMEP agreement the scope has been expanded. IEC/EN 60034-30 covers almost all motors (for example standard, hazardous area, marine, brake motors) Single speed, three-phase, 50 Hz and 60 Hz 2-, 4- or 6-pole Rated output from 0.75 to 375 kW Rated voltage U N up to 1000 V Duty type S1 (continuous duty) or S3 (intermittent periodic duty) with a rated cyclic duration factor of 80 % or higher Capable of operating direct online The following motors are excluded from IEC 60034-30: Motors made solely for converter operation Motors completely integrated into a machine (for example, pump, fan or compressor) that cannot be tested separately from the machine
Minimum efficiency values defined in IEC 60034-30:2008 (based on test methods specified in IEC 60034-2-1:2007)
IE1 Output kW 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 355 375 Standard efciency 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.7 94.0 94.0 94.0 94.0 94.0 72.1 75.0 77.2 79.7 81.5 83.1 84.7 86.0 87.6 88.7 89.3 89.9 90.7 91.2 91.7 92.1 92.7 93.0 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 70.0 72.9 75.2 77.7 79.7 81.4 83.1 84.7 86.4 87.7 88.6 89.2 90.2 90.8 91.4 91.9 92.6 92.9 93.3 93.5 93.8 94.0 94.0 94.0 94.0 94.0 IE2 High efciency 77.4 79.6 81.3 83.2 84.6 85.8 87.0 88.1 89.4 90.3 90.9 91.3 92.0 92.5 92.9 93.2 93.8 94.1 94.3 94.6 94.8 95.0 95.0 95.0 95.0 95.0 79.6 81.4 82.8 84.3 85.5 86.6 87.7 88.7 89.8 90.6 91.2 91.6 92.3 92.7 93.1 93.5 94.0 94.2 94.5 94.7 94.9 95.1 95.1 95.1 95.1 95.1 75.9 78.1 79.8 81.8 83.3 84.6 86.0 87.2 88.7 89.7 90.4 90.9 91.7 92.2 92.7 93.1 93.7 94.0 94.3 94.6 94.8 95.0 95.0 95.0 95.0 95.0 IE3 Premium efciency 80.7 82.7 84.2 85.9 87.1 88.1 89.2 90.1 91.2 91.9 92.4 92.7 93.3 93.7 94.0 94.3 94.7 95.0 95.2 95.4 95.6 95.8 95.8 95.8 95.8 95.8 82.5 84.1 85.3 86.7 87.7 88.6 89.6 90.4 91.4 92.1 92.6 93.0 93.6 93.9 94.2 94.6 95.0 95.2 95.4 95.6 95.8 96.0 96.0 96.0 96.0 96.0 78.9 81.0 82.5 84.3 85.6 86.8 88.0 89.1 90.3 91.2 91.7 92.2 92.9 93.3 93.7 94.1 94.6 94.9 95.1 95.4 95.6 95.8 95.8 95.8 95.8 95.8
ABB and efficiency standards As a global player committed to supplying safe, reliable and efficient motors, ABB designs and labels its motors for explosive atmospheres to comply with international efficiency standards published by the IEC. ABB determines efficiency values according to IEC/EN 60034-2-1 using the low uncertainty method (i.e. indirect method), with additional load losses determined by measurement. As the world market leader, ABB offers the largest range of LV motors available. It has long advocated the need for efficiency in motors, and high efficiency products have formed the core of its portfolio for many years. The core of ABB's Ex range is based on a full range of IE2 motors with many available from stock. Premium efficiency IE3 motors are also available for a major part of the range.
Product code pos. 12 A = foot-mounted, term.box top R = foot-mounted, term.box RHS L = foot-mounted, term.box LHS B = ange mounted, large ange
M000008
Foot- and ange-mounted IM B35 IM V15 IM V36 *) *) *) motor with feet, IM 2001 IM 2011 IM 2031 IM 2051 IM 2061 IM 2071 large ange
M000010
Foot- and ange-mounted IM B34 IM V17 motor with feet, IM 2101 IM 2111 IM 2131 IM 2151 IM 2161 IM 2171 small ange
M000011
Note: In the case of motors mounted with the shaft upwards , the user must provide some means to prevent water or other liquids from running down the shaft where this is expected to occur.
Surface treatment
ABB cast iron motors for explosive atmospheres are provided as standard with a painting system that corresponds to corrosion category C3M specified by ISO/EN 12944:2. ISO/EN 12944 divides durability into 3 ranges: low (L), medium (M) and high (H). Low (L) durability corresponds to 2-5 years, medium (M) to 5-15 years and high (H) to more than 15 years. ABB surface treatment corresponds to medium (M) durability. Durability does not represent a guaranteed time span. Instead it is a technical consideration that can help the owner to set up a maintenance program. Maintenance is often required at more frequent intervals because of fading, chalking, a compination of factors, or wear and tear, or for other reasons. Other corrosion categories (C4M and C5M) are available as options. In addition surface treatment according to Norsok requirements (755) for offshore environments is available as an option. Please see the variant code section for exact availability. The standard ABB colour is Munsell Blue 8B 4.5/3.25. Other colours are available and can be ordered with variant code 114.
Indoor atmospheres
Heated buildings with clean atmospheres, e.g. ofces, shops, schools, hotels. Unheated buildings where condensation may occur e.g. depots, sport halls Production rooms with high humidity and some air pollution e.g. foodprocessing plants, laundries, breweries, dairies Chemical plants, swimming pools, coastal ship- and boatyards. Buildings or areas with almost permanent condensation and with high pollution. Buildings or areas with almost permanent condensation and with high pollution.
ABB
Standard surface treatment Optional surface treatment with variant code 115
Bearings
ABB policy regards reliability as a vital issue in bearing design as well as in bearing lubrication systems. ABB therefore, as standard, follows the L1-principle for calculating regreasing intervals (meaning that 99 per cent of the bearings achieve or exceed the calculated grease lifetime). Lubrication intervals can also be calculated according to the L10 -principle, which means that 90 per cent of the motors are certain to achieve the interval time. L10 -values, which are normally double the L1 -values, are available from ABB on request. Guidelines for bearing life time according to the L1 principle: Aluminum motors
2 pole motors, 10 000 - 20 000 duty hours 1) 4 to 8 pole motors, 20 000 - 40 000 duty hours Cast iron motors 2 pole motors, 20 000 duty hours 1) 4 to 8 pole motors, 40 000 duty hours
1)
1)
Motors with permanently greased bearings Cast iron motors up to frame size 132 and aluminum motors up to frame size 250 are normally fitted with permanently greased bearings of type Z or 2Z. The exception is 2D DIP motors with aluminum frame sizes 63 to 132, which are fitted with 2RS bearings because higher protection is required.
1)
Motors fitted with grease nipples Cast iron motors from frame size 160 are fitted with regreasable bearings as standard.. Lubricate the motor when operating. For motors with lubrication systems it is recommended that a lubrication interval of two years is not exceeded in any case.
Lubrication
Lubricate the motor when operational. If a grease outlet plug is fitted, temporarily remove it when lubricating, or permanently remove it with auto lubrication. If the motor is fitted with a lubrication plate, use the values given, or use the values given in the table on the next page. These values are according to the L1 -principle, which is the ABB standard for all motors. The effectiveness of the motor lubrication should be checked by measuring the surface temperature of the bearing endshields during normal operating conditions. If the measured temperature is +80 C or above, the relubrication intervals must be shortened; i.e. the relubrication interval should be halved for every 15K increase in bearing temperature. If this is not possible, ABB recommends the use of lubricants suitable for high operating temperatures. These lubricants allow a normal relubrication interval and 15K increase in bearing temperature conditions. The following formula can be used to roughly convert L1 values to L10 values:
L10 = 2.0 x L1
3600 r/min
3000 r/min
1800 r/min
1500 r/min
1000 r/min
500-900 r/min
Ball bearings Lubrication intervals in duty hours 160 180 200 225 250 280 280 315 315 355 355 400 400 450 450 Roller bearings Lubrication intervals in duty hours 160 180 200 225 250 280 280 315 315 355 355 400 400 450 450 13 15 20 23 30 35 40 35 55 35 70 40 85 40 95 13 15 15 20 23 35 40 35 40 35 40 40 55 40 70 3600 3000 2100 1800 1200 900 900 900 4500 3900 3000 1600 1900 1600 1600 1600 1300 1300 7200 6600 5500 5100 4200 4000 2900 2000 1600 1300 8100 7500 6500 6000 5200 5300 3800 2800 2400 2000 10300 9700 8600 8200 7300 7000 5900 4800 4300 3800 10800 10200 9200 8700 7900 8500 6500 5400 4800 4400 13 15 20 23 30 35 40 35 55 35 70 40 85 40 95 13 15 15 20 23 35 40 35 40 35 40 40 55 40 70 7100 6100 4300 3600 2400 1900 1900 1900 1500 1500 8900 7800 5900 5100 3700 3200 3200 3200 2700 2700 14300 13100 11000 10100 8500 7800 5900 4000 3200 2500 16300 15100 13000 12000 10400 9600 7600 5600 4700 3900 20500 19400 17300 16400 14700 13900 11800 9600 8600 7700 21600 20500 18400 17500 15800 15000 12900 10700 9700 8700
The values above are valid for horizontal mounting motors and maximum bearing operating temperature + 80 C (ambient +25 C). Refer to the motor manual Low voltage Motors for explosive atmospheres for more information.
Transport locking
Motors with roller bearings or angular contact ball bearings are fitted with a transport lock before despatch to prevent damage to the bearings during transport. When the transport lock is fitted, the motor is provided with a warning sign. Locking may also be fitted in other cases where handling during transport could cause damage.
Axially-locked bearings
The table below shows axial locking of the bearings. See also variant code 042. Aluminum motors
Motor size 71-132 160-280 Foot-mounted motors D-end D-end Flange-mounted motors Large ange D-end D-end Small ange D-end -
Non-sparking and Increased safety motors: 71-450 D-end D-end Flameproof motors: 80-450 D-end D-end
In the case of voltage source PWM converters with a minimum switching frequency of 3 kHz or higher, the instructions provided in section B/2.2 can be used for preliminary dimensioning. B. Other safety criteria These criteria are imposed by the competent bodies in order to ensure the safe use of motors with converters in explosive atmospheres. 1. Type tests and certification ABB has type tested and certied the complete range of Ex d, Ex de, Ex nA and Ex t motors for operation with frequency converters. On request, ABB can supply type test reports based on the test procedure specified by the Notified Bodies for a representative number of motors with ACS800 and ACS550 converters. For other voltage source PWM converters, in most cases a combined type test is required to ensure safe operation. 2. Motor dimensioning for variable speed applications 2.1 General The voltage (or current) fed by the frequency converter is not purely sinusoidal. This may increase motor losses, vibration, and noise. Furthermore, a change in the distribution of the losses may affect the motor temperature balance and lead to increased temperature. When the motor is operating at low speeds the cooling capacity of the ventilation fan is decreased, which reduces the motors loadability. A separate constant speed fan can be used to increase cooling capacity and loadability at low speeds. When dimensioning a motor for variable speed applications, the continuous thermal dimensioning and short time overloads should be considered. 2.2 Thermal dimensioning with ABB ACS800 converters utilizing DTC control In the case of ABB ACS800 converters utilizing DTC control, dimensioning can be done using the loadability curves (or load capacity curves) in Figures 2 and 3. The loadability curves show the maximum permitted continuous output torque of the motor as a function of supply frequency. The output torque is given as a percentage of the motors nominal torque. The most convenient method to dimension the motor is to utilize ABBs DriveSize program. This tool can be downloaded from the ABB website (www.abb.com/ motors&generators) The loadability curves are based on nominal supply voltage. Note: the maximum speed of the motor must not be exceeded even if the loadability curves extend to 100 Hz. 2.3 Thermal dimensioning with ABB ACS550 converters In the case of ABB ACS550 converters, dimensioning can be done using the loadability curves in Figures 4 and 5. Also in
the case of ACS550 driven applications, the most convenient method to dimension the motor is to utilize ABBs DriveSize program. Note 1. The loadability curves in Figures 4 and 5 are based on a switching frequency of 3 kHz. Note 2. For constant torque applications the lowest permitted continuous operating frequency is 15 Hz. Note 3. For quadratic torque applications the lowest continuous operating frequency is 5 Hz. 2.4 Thermal dimensioning with other voltage source PWM-type converters For VSDs other than DTC-controlled ACS800 and ACS550 converters, preliminary dimensioning can be done using the loadability curves in Figures 4 and 5. The utilization of these curves assumes a minimum switching frequency of 3 kHz. To ensure safe operation, the combination of motor and frequency converter must either be tested for the specific protection type or thermal sensors must be fitted to control the surface temperature. Frequencies below 15 Hz shall be avoided or tested separately. Note: the actual thermal loadability of a motor may be lower than shown by the guideline curves. 2.5 Short time overloads Short time overloading is usually possible with ABB flameproof motors. For the exact values, please see the motors rating plate. Overloadability is specified by three factors: IOL TOL Maximum short time current Length of permitted overload period
TCOOL Cooling time required after each overload period. During the cooling period the motor current and torque must remain below the limit of permitted continuous loadability. 3. Operating speed When a motor is used with a frequency converter, its actual operating speed may deviate considerably from its nominal speed (i.e. the speed stamped on the rating plate). When operating at higher speeds, ensure that the highest permissible rotational speed of the motor, or the critical speed of the equipment as a whole, is not exceeded. The permitted maximum speed must be stated on a rating plate. This can be either a separate plate or the regular plate required for variable speed drive motors. 4. Thermal protection of windings Most ABB Ex motors are equipped with PTC thermistors to prevent the winding temperatures from exceeding the thermal limits of the insulation materials (usually Insulation Class F). Please check the product specific data in the corresponding section of this catalog.
In countries where the ATEX requirements are in force must, if the motor certificate so requires, the thermistors be connected to a thermistor circuit relay. The relay must function independently and that is dedicated to reliably trip off the supply to the motor according to the requirements of the Essential Health and Safety Requirements in Annex II, item 1.5.1 of the ATEX Directive 94/9/EC. The latest motor certificates, like for the flame proof motor range do no longer require connection of thermistors but connection is still recommended due to the additional protection the thermistors give. In countries where the ATEX requirements are not in force, it is nevertheless recommended that the thermistors are connected to a thermistor circuit relay that functions independently and will reliably trip off the supply to the motor. Note: local installation rules may either require certification of the relay or allow the thermistors to be connected to equipment other than a thermistor relay, such as the control inputs of a frequency converter. Note: the above recommendations do not apply to increased safety e motors. 5. Rating plates The following parameters must be shown on the rating plates of hazardous area motors intended for variable speed operation:
speed or frequency range power range voltage or current range type of torque (constant or quadratic) converter type and required minimum switching frequency
These parameters shall be used while checking the suitability of a specific motor for its intended application and for setting the limits of operation for the converter. C. Technical criteria 1. Lubrication The effectiveness of the motor lubrication should be checked by measuring the surface temperature of the bearing endshields under normal operating conditions. For more information, see the Manual for Motors for explosive atmospheres. In continuous operation at very low speeds, as well as at low temperatures, the lubrication capabilities of standard greases may not be sufficient, making it necessary to use special greases with additives. If the motor is equipped with sealed bearings (i.e. bearings greased for life) any deviation in the operating temperature from the design temperature will result in a change in the lifetime of the bearing. 2. Winding insulation The output voltage of voltage source frequency converters consists of steep voltage pulses. These pulses can be even higher and steeper when arriving at the motor terminals due to reflecting pulses in the cables. The motors insulation must therefore be selected according to the actual pulses at the motor terminals. 2.1 Phase to phase voltages The maximum permitted phase to phase voltage peaks at the motor terminals as a function of pulse rise time can be seen in Figure 1. Figure 1. Permitted phase to phase voltage peaks at motor terminals as a function of rise time.
M000732
2,20
2,00 1,80
Peak voltage ULL, kV
1,60
1,40
1,20
M000733a
The highest curve (ABB Special Insulation) applies to random wound motors with a special winding insulation for frequency converter supply, variant code 405. The ABB Standard Insulation curve applies to all other random wound motors covered by this catalog.
M000408
1,00
2.2 Phase to ground voltages The permitted phase to ground voltage peaks at the motor terminals are: Standard Insulation 1300 V peak Special Insulation 1800 V peak
3.1 Elimination of bearing currents with ABB ACS800 and ACS550 converters In the case of ABB ACS800 and ACS550 converters with a diode supply unit (uncontrolled DC voltage), the following methods must be used to avoid harmful bearing currents in the motors:
Frame size Preventive measures No action needed Insulated non-drive end bearing Insulated non-drive end bearing AND Common mode lter at the converter
2.3 Selection of winding insulation for ACS800 and ACS550 supplied motors In the case of ABB ACS800 and ACS550 single drives with a diode supply unit (uncontrolled DC voltage), the motor winding insulation and frequency converter output filters can be selected using Table 2. Table 2. Selection of motor winding insulation and converter output filters for motors supplied by ABB ACS800 or ACS550 drives with uncontrolled DC voltage.
Nominal supply voltage UN of converter Winding insulation and lters required ABB Standard insulation
Common mode filters Common mode filters reduce common mode currents and thus decrease the risk of bearing currents. Common mode filters do not significantly affect the phase or main voltages on the motor terminals. For more information, please see ABB Drives catalogues Insulated bearings Bearings with aluminum oxide insulated and sealed inner or outer bores are used as standard. Hybrid bearings, i.e. bearings with non-conductive ceramic rolling elements, can also be used in special applications. More information on selection of the correct parts is available on request. 3.2 Elimination of bearing currents with all other converters The user is responsible for protecting the motor and driven equipment from harmful bearing currents. The instructions provided in section 3.1 can be followed, but their effectiveness cannot be guaranteed in all cases. 4. Cabling, grounding and EMC The use of a frequency converter places greater demands on the cabling and grounding of the drive system. To provide proper grounding and ensure compliance with any applicable EMC requirements, motors above 30 kW shall be cabled using shielded symmetrical cables and EMC glands, i.e. cable glands providing 360 bonding. Symmetrical and shielded cables are also highly recommended for smaller motors. For motors in frame size IEC 280 and upward, additional potential equalization between the motor frame and the driven equipment is needed, unless both are mounted on a common steel base. In this case, the high frequency conductivity of the connection provided by the steel base should be checked. More information about grounding and cabling of variable speed drives can be found in the manual Grounding and cabling of the drive system (Code: 3AFY 61201998) and material on fulfilling the EMC requirements can be found in the relevant converter manuals. Please note that proper cable glands providing 360 bonding, or equivalent, must also be used for the converter and safety switch, if fitted. The correct grounding of the motor and driven equipment is also necessary for the avoidance of bearing voltages and currents.
ABB Standard insulation + dU/dt lters OR ABB Special insulation (variant code 405) ABB Special insulation (variant code 405) AND dU/dt-lters at converter output ABB Special insulation (variant code 405)
For more information on dU/dt filters, please see relevant ABB Drives catalogs. For more information on resistor braking and converters with controlled supply units, please contact ABB. 2.4 Selection of winding insulation with all other converters The voltage stresses must be restricted so they remain below the accepted limits. The effect of any filters that are fitted must be taken into account when dimensioning the motor. 3. Bearing currents Bearing voltages and currents must be avoided in all variable speed applications to ensure the reliability and safety of the application. For this purpose insulated bearings or bearing constructions, common mode filters and suitable cabling and grounding methods must be used.
D. Loadability curves of motors for explosive atmospheres The loadability curves shown in Figures 2 and 3 are based on type tests using ACS800 frequency converters with DTC control. The loadability curves assume that the nominal frequency of the motor (i.e. field weakening point) is 50 Hz or 60 Hz and that the motor control mode (parameter 99.04) is DTC. The DriveSize dimensioning program also utilizes the same curves.
For VSDs other than DTC-controlled ACS800 converters, preliminary dimensioning can be done using the guideline loadability curves in Figures 4 and 5.
Loadability curves with ACS800 converters utilizing DTC control Figure 2. Flameproof motors Ex d, Ex de T4, cast iron dust ignition protection motors Ex t T150 C; nominal frequency of motor 50/60 Hz 50 Hz
T/TN,% 120 110 100 90 80 70
Size 450 Separate cooling size 450 Separate cooling sizes 160-400
60 Hz
T/TN,% 120 110 100 90 80
Separate cooling size 450 Separate cooling sizes 160-400
70
Size 450
M000181b
50 40
Sizes 160-400
M000274b
60
60 50 40
Sizes 80-132 Sizes 160-400
Sizes 80-132
Figure 3. Non-sparking motors Ex nA, cast iron and aluminum dust ignition protection motors Ex t T125 C; nominal frequency of motor 50/60 Hz 50 Hz 60 Hz
M000182
M000275
Guideline loadability curves with ACS550 converters and other voltage source PWM-type convereters Figure 4. Flameproof motors Ex d, Ex de T4, cast iron dust ignition protection motors Ex t T150 C; nominal frequency of motor 50/60 Hz 50 Hz 60 Hz
M000276
M000278
Note: Motors have to be protected against excessive surface temperatures by inbuild direct temperature control.
Loadability curves with ACS 550 converters Figure 5. Non-sparking motors Ex nA , cast iron dust ignition protection motors Ex t T125 C; nominal frequency of motor 50/60 Hz 50 Hz 60 Hz
M000277
M000279
Flameproof motors Ex d IIB/IIC T4 Gb Totally enclosed squirrel cage three phase low voltage motors, Sizes 80 to 450, 0.55 to 710 kW
Mechanical design
Drain holes
Flameproof Ex d motors are provided without drain holes as standard. Drain holes with certified metal plugs are available as an option. Please see variant code section.
Closed
Open Open
Bearing seals
The following bearing seals are used as standard, special seals like radial seal are available as option. Please see variant code section.
M000707
Standard delivery if nothing else is informed Cable entries for supply cables
Motor size Pole number Terminal box type Threaded Cable Ex d plug Single core holes gland mm2 for rated 80-90 100-132 160-180 200-250 280 315 355 SMA, SMB, SMC 355 SMC 355 SMC 355 SMA, SMB 355 ML, LK 400 450 2-8 2-8 2-8 2-8 2-8 2-8 2-4 6 8 6-8 2-8 2-8 6-8 25 25 63 160 210 370 750 750 370 370 750 750 750 1 x M25 2 x M32 2 x M40 2 x M50 2 x M63 2 x M75 2 x M75 2 x M75 2 x M75 2 x M75 2 x M75 2 x M75 2 x M75 1 x M32 1 x M40 1 x M50 1 x M63 1 x M75 1 x M75 1 x M75 1 x M75 1 x M75 1 x M75 1 x M75 1 x M75 power 10 10 35 70 2 x 150 2 x 240 4 x 240 4 x 240 2 x 240 2 x 240 4 x 240 4 x 240 4 x 240 M5 M5 M6 M10 M12 M12 M12 M12 M12 M12 M12 M12 M12 80-132 160-450 2-8 2-8 1xM20 2xM20 1xM20 1xM20 Terminal bolt cross section size 6 x
Earthings on motor
Motor size 80-132 160-180 200-250 280-315 355-450 Frame M6 M6 M8 M10 M10 Terminal box M6 M6 M8 2xM10 2xM10
Examples of terminal boxes and connection parts Below pictures show a collection of terminal boxes and connection parts.
M000708
M000709
M000711
M000712
M000714
M000715
M000717
M000716
M000713
M000710
1. Main terminal box and maximum single core cross section Larger than standard single core cross section is available using variant code 300 as option according to the table below. Please check also the capacity of the cable entry to make sure the cables fit.
Standard terminal box 25 63 160 210 370 750 Max single cross section per phase mm2 35 95 120 2 x 240 2 x 300 4 x 500
The accessories for using the maximum single core cross sections are not included as standard. For this option please use variant code 300 (Increased single core cross section). Each terminal box has got limited maximum cable entry size, please request if necessary.
NPT threads as option, variant code 730 = Prepared for NPT cable glands
Motor size Main cable entries Thread 1x3/4" 2x3/4" 2x1 1/4" 2x1 1/2" 2x2" 2x3" NPT plug 1x3/4" 1x1 1/4" 1x1 1/2" 1x2" 1x3" Max. possible thread size 1x1" 1x1" 1 or 2x1 1/2" 1 or 2x2" 1 or 2x3" 1 or 2x3"
80-132 160-450
M000366
M000735
M000203
M000367
M000366
Ex d - M3JP
Motor size 80-132 160-180 200-250 280 315-355 355-450 Terminal box 25 63 160 210 370 750 A1 180 251 339 465 790 707 B1 170 242 291 370 490 466 H1 114 127 226 260 420 387
M000204
Please note that motors type Ex d and IIC in size 250 and above with roller bearings may require detailed information about power transmission; please consult ABB.
If the radial force is applied between points X0 and Xmax, the permissible force FR can be calculated from the following formula:
Cast iron motors Permissible radial forces according to L10 principle Flameproof motor Ex d IIB/IIC, motor sizes 80 to 132
Motor size Poles Length of shaft extention E (mm) 80 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 40 40 40 40 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80 80 40,000 hours FX0 (N) 619 780 893 983 561 803 919 1011 553 1050 1267 1395 553 1050 1267 1394 1354 1772 2028 2234 Fx max (N) 524 663 759 834 473 677 775 853 457 868 1047 1153 457 868 1047 1152 1112 1454 1665 1833
90
100
112
132
Cast iron motors Permissible radial forces according to L10 principle Flameproof motors Ex d IIB/IIC, motor sizes 160 to 450
Motor size Poles Lengt of shaft extension E (mm) 110 110 110 110 110 110 110 110 110 110 110 110 110 140 140 140 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 210 140 210 140 210 170 210 170 210 210 Ball bearings IIB 1) 40,000 hours FX 0 (N) 2530 3180 3650 4020 2900 3660 4190 4620 3830 4820 5520 6080 4350 5490 6280 6920 5390 6790 7760 8550 5840 7260 8300 9150 5810 9030 10310 11370 5850 9000 10270 11330 5790 11930 5770 11980 5500 12050
2) 2) 2) 2) 2)
FX max(N) 2120 2670 3040 3040 2440 3080 3520 3880 3150 3980 4550 5000 3660 2800 2800 2800 4350 5480 6270 6900 4900 6110 6980 7700 4960 7470 8530 9410 5080 7620 8500 9380 5090 9890 5120 10090 5000 10450
2) 2) 2) 2) 2)
FX0 (N) 2530 3180 3650 4020 2900 3660 4190 4620 3830 4820 5520 6080 4350 5490 6280 6920 5390 6790 3000 3000
2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2)
FXmax(N) 2120 2670 3040 3040 2440 3080 3520 3880 3150 3980 4550 5000 3660 2800 2800 2800 2900 2800 2800 2800
2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2)
FX0 (N) 6400 7600 7600 7600 6970 8500 8500 8500 9510 11710 13230 14420 11650 14340 16190 17300 15420 18980 21000 21000 16550 20100 22690 24740 16540 26590 39030 32740 16710 26580 30010 32730 NA NA NA NA NA NA NA NA NA NA NA
FX max(N) 1800 1800 1800 1800 2700 2700 2700 2700 7000 7000 7000 7000 7000 7200 7200 7200 6700 9200 9200 9200 6000 9200 9200 9200 6000 9600 9600 9600 5850 13040 10040 9940 NA NA NA NA NA NA NA NA NA NA NA
FX0 (N) 6400 7600 7600 7600 6970 8500 8500 8500 9510 11710 13230 14420 9300 9300 9300 9300 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
FX max(N) 1800 1800 1800 1800 2700 2700 2700 2700 4200 4200 4200 4200 3000 2200 2200 2200 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
160 ML_
180 ML_
200 ML_
225 SM_
250 SM_
280 SM_
315 SM_
315 ML_
355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
1) 2)
IIB on request, require special construction. Flameproof motors Ex d IIC -sizes 280 to 315 only allowed for direct coupling application.
FAD
Flameproof motors Ex d, motor sizes 80 to 450. Mounting arrangement IM B3
Motor size 40,000 hours 2-pole FAD N 660 740 1100 1100 1530 2050 2570 3300 3710 5200 4870 4780 4730 1660 1570 1440 810 810 NA 4-pole FAD N 820 900 1320 1320 1870 2620 3230 4180 4690 6400 6140 7170 7080 5760 5640 5460 4250 4250 NA
FAZ
80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
1)
FAZ N 300 220 220 220 500 1440 1470 2040 2240 2100 2870 2780 2730 5460 5370 5240 5810 5810 NA
FAZ N 460 380 430 430 840 2010 2130 2920 3230 3310 4140 5170 5080 9560 9440 9260 10250 10250 NA
6-pole FAD N 940 1010 1480 1480 2110 3060 3730 4820 5410 7260 7040 8210 8100 7060 6880 6680 5510 5410 5630
M000022
FAZ N 580 490 590 590 1080 2440 2630 3560 3940 4160 5040 6210 6100 10860 10680 10480 11510 11410 11630
8-pole FAD N 1030 1110 1610 1610 2320 3410 4140 5360 6010 8000 7840 9180 9060 8290 8100
1)
FAZ N 670 590 720 720 1280 2790 3040 4100 4540 4900 5840 7180 7070 12090 11900
1)
6630
1)
12630
1)
6920
12920
On request
FAZ
M000023
FAD
Mounting arrangement IM V1
Motor size 40,000 hours 2-pole FAD N 690 780 1180 1180 1700 2440 3120 3960 4570 6240 6440 6950 7280 5330 5860 6600 8010 8010 NA 4-pole FAD N 860 950 1430 1430 2080 3160 3980 5030 5770 7720 8170 9820 10300 11110 11810 12850 13680 13680 NA 6-pole FAD N 970 1080 1600 1600 2380 3590 4490 5820 6660 8930 9580 11760 12330 13720 14718 15800 16610 17180 22090
80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
1)
FAZ N 280 190 170 170 390 1180 1100 1590 1650 1380 1780 1270 940 2890 2360 1630 730 730 NA
FAZ N 440 340 360 360 690 1650 1630 2340 2500 2410 2760 3350 2870 5820 5130 4080 3650 3650 NA
FAZ N 550 450 510 510 900 2090 2130 2890 3100 3047 3340 3810 3240 6270 5280 4190 3840 3270 150
8-pole FAD N 1070 1170 1730 1730 2580 3950 4890 6370 7280 9690 10380 12740 13310 14980 15970
1)
FAZ N 650 540 640 640 1110 2430 2550 3430 3700 3780 4150 4780 4210 7530 6540
1)
On request
Rating plates
The rating plates are in table form giving values for speed, current and power factor for three voltages: 400V-415V-690V as standard. Other voltage and frequency combinations are possible and can be ordered with variant codes 002 or 209. Please see Variant code section. The following information will be shown on the motor rating plate: Lowest nominal efficiency at 100 %, 75 % and 50 % rated load Efficiency level Year of manufacture Type of protection Apparatus group Temperature class Identification number of the certification body Certificate number (both ATEX and IECEx are stamped on the rating plate as standard)
M000737
Position 14
Generation code G/H Generation code is followed by variant codes according to the hazardous area, see below and on corresponding pages with variant codes: 461 Ex d(e) design, Group IIC
IE2
kW type 3000 r/min = 2-poles 0.75 M3JP 80 MA 1.1 M3JP 80 MB 1.5 M3JP 90 SLA 2.2 M3JP 90 SLC 3 M3JP 100 LA 4 M3JP 112 MB 5.5 M3JP 132 SMB 7.5 M3JP 132 SMD 11 M3JP 160 MLA 15 M3JP 160 MLB 18.5 M3JP 160 MLC 22 M3JP 180 MLA 30 M3JP 200 MLA 37 M3JP 200 MLC 45 M3JP 225 SMB 55 M3JP 250 SMA 75 M3JP 280 SMA 90 M3JP 280 SMB 110 M3JP 315 SMA 132 M3JP 315 SMB 160 M3JP 315 SMC 200 M3JP 315 MLA M3JP 355 SMA 250 3) M3JP 355 SMB 315 3) M3JP 355 SMC 355 3) 400 3) M3JP 355 MLA M3JP 355 MLB 450 3) M3JP 355 LKA 500 3) M3JP 400 LA 560 4) M3JP 400 LKA 560 4) 630 4) M3JP 400 LB M3JP 400 LKB 630 4) M3JP 400 LC 710 4) M3JP 400 LKC 710 4) 3000 r/min = 2-poles 2) 22 M3JP 160 MLD 30 M3JP 180 MLB 37 M3JP 180 MLC 45 M3JP 200 MLE 55 M3JP 225 SMC 5) M3JP 225 SMD 67 75 M3JP 250 SMB 1) 2) 5) M3JP 250 SMC 90 110 M3JP 280 SMC
1) 2) 3)
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.87 1.55 7.3 2.5 3.7 0.87 2.2 5.9 3.7 3.0 0.88 3 6.7 4.9 3.0 0.89 4.2 7.8 7.3 2.7 0.90 5.5 6.8 9.8 2.2 0.89 7.5 7.8 13.2 3.6 0.90 10.1 6.9 18 2.4 0.90 13.6 7.6 24.5 2.8 0.89 19.7 7.2 35.8 2.6 0.89 26.6 7.2 48.9 3.0 0.90 32.3 7.5 60.2 2.8 0.90 38.4 7.0 71.5 2.5 0.88 52.7 7.4 96.9 3.0 0.89 64.1 7.5 119 2.8 0.87 79.5 7.2 144 2.7 0.89 94.5 7.8 176 2.4 0.88 130 7.6 240 2.1 0.90 152 7.4 288 2.1 0.86 194 7.6 352 2.0 0.88 227 7.4 422 2.2 0.89 271 7.5 512 2.3 0.90 335 7.7 640 2.6 0.89 423 7.7 800 2.1 0.89 533 7.0 1009 2.1 0.88 608 7.2 1136 2.2 0.88 677 7.1 1280 2.3 0.90 743 7.9 1440 2.2 0.90 827 7.5 1601 2.0 0.89 934 7.8 1789 2.1 0.89 934 7.8 1789 2.1 0.89 1048 7.8 2014 2.2 0.89 1048 7.8 2014 2.2 0.89 1180 7.8 2269 2.6 0.89 1180 7.8 2269 2.6 High-output design 0.90 38.6 7.3 71.7 2.7 0.90 52 6.8 97.3 2.3 0.90 63.9 7.9 119 2.9 0.88 79.1 7.3 145 2.9 0.88 96 7.1 177 2.6 0.86 119 7.4 215 2.8 0.89 129 7.9 241 2.6 0.90 153 7.7 289 2.6 0.90 185 7.9 352 2.4
Moment Sound of inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.0006 0.0007 0.001 0.0014 0.0036 0.0043 0.009 0.012 0.043 0.052 0.062 0.089 0.15 0.19 0.26 0.49 0.8 0.9 1.2 1.4 1.7 2.1 3 3.4 3.6 4.1 4.3 4.8 7.9 7.9 8.2 8.2 9.3 9.3 0.07 0.13 0.13 0.22 0.29 0.31 0.57 0.59 1.15
Is / IN
37 39 50 53 70 73 101 109 213 222 233 265 310 340 400 460 725 765 980 1040 1125 1290 1790 1870 1940 2190 2270 2510 3230 3230 3330 3330 3580 3580 239 298 298 345 420 430 500 510 825
59 59 61 61 65 65 71 71 71 71 69 69 74 75 76 75 77 77 78 78 78 78 83 83 83 83 83 83 82 82 82 82 82 82 77 78 77 79 80 78 80 80 77
Temperature rise class F Efciency class IE1 3 dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
4)
Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045 For 400-415 V 50 Hz (380 V 50 Hz voltage code B)
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
5)
IE2
kW type 1500 r/min = 4-poles 0.55 M3JP 80 MA 0.75 M3JP 80 MB 1.1 M3JP 90 SLA 1.5 M3JP 90 SLC 2.2 M3JP 100 LA 3 M3JP 100 LB 4 M3JP 112 MC 5.5 M3JP 132 SMB 7.5 M3JP 132 SMD 11 M3JP 160 MLC 15 M3JP 160 MLE 18.5 M3JP 180 MLA 22 M3JP 180 MLB 30 M3JP 200 MLB 37 M3JP 225 SMB 45 M3JP 225 SMC 55 M3JP 250 SMA 75 M3JP 280 SMA 90 M3JP 280 SMB 110 M3JP 315 SMA 132 M3JP 315 SMB 160 M3JP 315 SMC 200 M3JP 315 MLA 250 M3JP 355 SMA 315 M3JP 355 SMB 355 M3JP 355 SMC 400 M3JP 355 MLA 450 M3JP 355 MLB 500 M3JP 355 LKA 560 M3JP 400 LA 560 M3JP 400 LKA 630 M3JP 400 LB 630 M3JP 400 LKB M3JP 400 LC 710 1) M3JP 400 LKC 710 1) 1500 r/min = 4-poles 18.5 M3JP 160 MLF 2) M3JP 160 MLG 22 1) 2) M3JP 180 MLC 30 37 M3JP 200 MLC 55 M3JP 225 SMD 2) M3JP 225 SME 62 75 M3JP 250 SMB 2) M3JP 250 SMC 86 110 M3JP 280 SMC
1) 2)
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.73 1.41 4.9 3.6 2.3 0.76 1.77 5.2 5 2.2 0.77 2.4 5.9 7.3 2.8 0.79 3.2 6.5 10 2.3 0.86 4.3 7.0 14.5 2.7 0.83 6 7.3 19.8 2.7 0.78 8.3 8.7 26.1 3.0 0.79 11.3 7.4 36 3.0 0.75 16.1 6.8 49 3.3 0.82 21.2 7.8 71.4 3.0 0.84 28 7.8 97.6 3.0 0.83 35.1 7.2 119 2.6 0.83 41.7 6.8 142 2.5 0.85 54.4 7.4 194 3.0 0.85 67.1 7.6 238 3.2 0.88 78.4 7.6 290 3.2 0.84 100 7.2 355 2.5 0.85 134 6.9 482 2.5 0.86 159 7.2 579 2.5 0.86 194 7.2 706 2.0 0.86 232 7.1 847 2.3 0.85 284 7.2 1027 2.4 0.86 351 7.2 1285 2.5 0.86 437 7.1 1604 2.3 0.86 551 7.3 2021 2.3 0.86 621 6.8 2279 2.4 0.85 705 6.8 2565 2.3 0.86 780 6.9 2884 2.3 0.86 865 6.8 3204 2.0 0.85 982 7.4 3586 2.4 0.85 982 7.4 3586 2.4 0.87 1077 7.6 4034 2.2 0.87 1077 7.6 4034 2.2 0.86 1227 7.6 4547 2.4 0.86 1227 7.6 4547 2.4 High-output design 0.83 35 7.8 120 3.2 0.81 43.1 7.9 143 3.3 0.81 57.9 7.1 194 2.8 0.82 70 7.5 239 3.5 0.83 101 7.4 354 3.4 0.84 113 7.7 400 3.5 0.86 133 7.6 485 2.8 0.85 155 7.8 556 2.9 0.86 194 7.6 707 3.0
Moment Sound of inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.001 0.0012 0.002 0.003 0.0075 0.0081 0.013 0.023 0.034 0.096 0.13 0.19 0.21 0.34 0.42 0.49 0.72 1.25 1.5 2.3 2.6 2.9 3.5 5.9 6.9 7.2 8.4 8.4 10 15 15 16 16 17 17 0.13 0.13 0.248 0.34 0.55 0.55 0.88 0.98 1.85
Is / IN
38 40 51 53 70 72 81 111 114 232 255 277 285 340 390 425 450 725 765 1000 1060 1100 1260 1800 1970 2010 2330 2330 2690 3200 3200 3580 3580 3680 3680 255 255 304 340 445 445 505 530 825
59 59 54 54 52 52 52 60 60 62 61 62 62 61 67 67 66 68 68 70 70 70 70 74 74 78 78 78 78 78 78 78 78 78 78 68 68 66 73 68 74 73 74 68
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
IE2
kW type 1000 r/min = 6-poles 0.37 M3JP 80 MA 0.55 M3JP 80 MB 0.75 M3JP 90 SLA 1.1 M3JP 90 SLC 1.5 M3JP 100 LA 2.2 M3JP 112 MB 3 M3JP 132 SMB 4 M3JP 132 SMC 5.5 M3JP 132 SMD 7.5 M3JP 160 MLA 11 M3JP 160 MLB 15 M3JP 180 MLB 18.5 M3JP 200 MLA 22 M3JP 200 MLB 30 M3JP 225 SMB 37 M3JP 250 SMA 45 M3JP 280 SMA 55 M3JP 280 SMB 75 M3JP 315 SMA 90 M3JP 315 SMB 110 M3JP 315 SMC 132 M3JP 315 MLA 160 M3JP 355 SMA 200 M3JP 355 SMB 250 M3JP 355 SMC 315 M3JP 355 MLB 355 M3JP 355 LKA 400 M3JP 400 LA 400 M3JP 400 LKA 450 M3JP 400 LB 450 M3JP 400 LKB 500 M3JP 400 LC 500 M3JP 400 LKC 560 M3JP 400 LD 560 M3JP 400 LKD 610 M3JP 450 LA 1000 r/min = 6-poles 1) 2) 14 M3JP 160 MLC M3JP 180 MLC 18.5 2) 2) 30 M3JP 200 MLC 2) M3JP 225 SMC 37 45 M3JP 250 SMB 75 M3JP 280 SMC
1) 2)
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.64 1.14 4.8 3.7 3.4 0.70 1.55 4.3 5.5 2.8 0.69 2 4.9 7.5 2.1 0.71 2.8 4.7 11.2 1.8 0.74 3.6 4.2 15 2.3 0.76 5 5.9 22.1 2.2 0.77 6.7 6.1 29.8 2.1 0.74 9.2 6.6 39.6 2.3 0.72 12.5 6.9 54.3 2.3 0.81 15.3 6.5 74.2 1.9 0.81 21.7 7.8 108 2.3 0.82 29.2 7.2 147 1.9 0.82 35.8 7.1 179 3.2 0.82 42.2 7.5 213 3.2 0.82 57.2 7.4 290 3.4 0.81 70.8 7.2 357 3.2 0.84 82.7 7.0 434 2.5 0.84 100 7.0 530 2.7 0.82 139 7.4 721 2.4 0.84 163 7.5 866 2.4 0.83 201 7.4 1059 2.5 0.83 240 7.5 1271 2.7 0.83 291 7.0 1538 2.0 0.84 359 7.2 1923 2.2 0.83 454 7.4 2404 2.6 0.83 572 7.0 3032 2.5 0.83 645 7.6 3417 2.7 0.82 731 7.1 3846 2.3 0.82 731 7.1 3846 2.3 0.82 819 7.4 4323 2.4 0.82 819 7.4 4323 2.4 0.83 900 7.2 4808 2.5 0.83 900 7.2 4808 2.5 0.85 981 7.4 5385 2.4 0.85 981 7.4 5385 2.4 0.83 1098 7.1 5860 1.4 High-output design 0.75 30.2 7.9 137 2.8 0.74 40 7.2 181 2.0 0.80 59 7.5 291 3.5 0.83 69.8 7.1 359 3.0 0.82 85 7.2 435 3.3 0.84 136 7.3 723 2.8
Moment Sound of inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.0022 0.0022 0.0037 0.0048 0.012 0.014 0.032 0.034 0.039 0.088 0.126 0.25 0.37 0.43 0.64 1.16 1.85 2.2 3.2 4.1 4.9 5.8 7.9 9.7 11.3 13.5 15.5 17 17 20.5 20.5 22 22 24 24 31 0.126 0.25 0.49 0.75 1.49 2.85
Is / IN
38 38 52 53 69 72 105 107 109 226 253 304 300 320 385 455 705 745 930 1030 1100 1250 1630 1790 2010 2370 2690 3180 3180 3430 3430 3580 3580 3680 3680 4320 253 304 340 415 500 825
50 50 44 44 54 54 57 57 62 57 65 58 66 61 61 66 66 66 70 70 70 68 75 75 75 75 75 76 76 76 76 76 76 77 77 81 64 61 65 64 65 66
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
Power IN Is TN factor cos A IN Nm CENELEC-design 0.48 0.88 3.3 2.3 0.58 0.97 3.2 3.3 0.63 1.26 3.0 5 0.61 1.89 3.1 7.5 0.59 2.4 3.8 9.9 0.57 3.6 3.7 14.6 0.59 4.7 3.5 20 0.65 6 4.7 29.1 0.70 7.7 4.1 40.3 0.71 9.3 5.4 52.9 0.71 12.8 5.8 72.6 0.70 18 5.7 99.7 0.72 24.9 5.7 145 0.79 30.4 7.0 195 0.74 40 6.1 240 0.77 45.5 6.5 287 0.78 60.7 6.7 389 0.78 73.8 7.3 476 0.78 89.3 7.6 579 0.81 104 7.1 707 0.82 140 7.1 966 0.82 168 7.4 1159 0.83 203 7.3 1419 0.80 251 7.5 1694 0.80 303 7.6 2053 0.80 378 7.4 2570 0.80 472 7.5 3213 0.81 584 7.0 4043 0.81 584 7.0 4043 0.83 641 6.8 4562 0.83 641 6.8 4562 0.82 731 7.4 5134 0.82 731 7.4 5134 0.82 789 6.2 5519 0.82 861 6.6 6032 0.81 982 7.3 6793 0.80 1124 7.9 7690 CENELEC-design 0.80 37.1 6.9 240 0.78 61.2 6.3 391 0.78 74.2 7.5 479 0.80 106 7.9 708
38 38 50 52 69 69 73 107 109 251 251 251 298 315 370 385 455 705 745 930 1030 1100 1250 1630 1790 1930 2370 3180 3180 3480 3480 3680 3680 3920 4160 4520 4960 335 410 500 825
36 36 36 36 54 54 54 59 59 59 53 55 63 56 55 56 56 65 65 62 62 64 72 69 69 69 72 71 71 71 71 71 71 80 80 80 80 57 59 59 65
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
90 M NA P S P P P NA NA S NA NA NA NA NA NA NA S NA NA NA NA NA NA NA NA NA R S NA P P
100 M NA P S P P P NA NA S NA NA NA NA NA NA NA S NA NA NA NA NA NA NA NA NA R S NA P P
112 M NA P S P P P NA NA S NA NA NA NA NA NA NA S NA NA NA NA NA NA NA NA NA R S NA P P
132 M NA P S P P P NA NA S NA NA NA NA NA NA NA S NA NA NA NA NA NA NA NA NA R S NA P P
160 M NA P S P P P NA M P S S NA P P P P M NA P P M P P P M P R M P P P
180 M NA P S P P P NA M P S S NA P P P P M NA P P M P P P M P R M P P P
200 M P P S P P P NA M P S S NA P P P P M NA P P M P P P M P R M P P P
225 M P P S P P P NA M P S S NA P P P P M NA P P M P P P M P NA M P P P
250 M P P S P P P NA M P S S NA P P P P M NA P P M P P P M P NA M P P P
280 M P P S P P P P M P S S P P P P P NA P P P S P P P M P NA M P P P
315 P P P S P P P P P P S S P P P P P NA P P P S P P P P P NA P P P P
355 P P P S P P P P NA P S S P P P P P NA P P P S P P P P P NA P S P P
400 P P P S P P P P NA P S S P P P P P NA P P P S P P P P P NA P S P P
450 P P P S P P P P NA P S S P P P P P NA P P P S P P P P P NA P S P NA
Sea freight packing Packing of motor in vertical mounting position Wooden sea freight packing Vibration acc. to Grade A (IEC 60034-14). Vibration acc. to Grade B (IEC 60034-14). Balanced without key. Full key balancing. Transport lock for bearings Roller bearing at D-end Heat resistant grease Bearings regreasable via grease nipples SPM compatible nipples for vibration measurement Angular contact bearing at D-end, shaft force away from bearing Pt100 2-wire in bearings Double Pt100, 2-wire in bearings Double Pt100, 3-wire in bearings Pt100 3-wire in bearings 2Z bearings greased for life at both ends Outlet grease collector Nipples for vibration measurement : SKF Marlin Quick Connect stud CMSS-2600-3 Provision for vibration sensors (M8x1) Lubrication information plate Grease nipples JIS B 1575 Pt 1/8 Type A Stainless steel SPM nipples Stainless steel grease nipples Grease nipples flat type DIN 3404, thread M10x1 Grease nipples JIS B 1575 Pt 1/8" pin type
M NA P S P P P NA NA S NA NA NA NA NA NA NA S NA NA NA NA NA NA NA NA NA R S NA P P
Balancing
NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Variant Motor designed for ambient temperature -20 C to -40 C Motor designed for ambient temperature -40 C to -55 C Corrosion protected stator and rotor core Special design shaft upwards (V3, V36, V6) for outdoor mounting
Frame size 80 P P S P 90 P P S P 100 P P S P 112 P P S P 132 P P S P 160 P P S P 180 P P S P 200 P P S P 225 P P S P 250 P P S P 280 P P P R 315 P P P R 355 P P P NA 400 P P P NA 450 NA NA P NA
Cooling system 044 Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors 045 Unidirectional fan for reduced noise level. Rotation counter clockwise seen from D-end. Available only for 2-pole motors 068 075 183 206 422 791 Coupling 035 Assembly of customer supplied couplinghalf Documentation 141 448 067 334 336 461 462 463 464 508 812 813 814 816 Binding dimension drawing Draining holes with metal plugs External earthing bolt Ex t, Dust group III B T125C Db (nonconductive dust) acc. IEC/EN60079-31 Ex t, Dust group III C T125 Db (conductive dust) acc. IEC/EN60079-31 Ex d(e) design, Group II C Ex d(e) design, temperature class T5 Ex d(e) design, temperature class T6 Alleinschutz' design. Certification of flame proof motor and protection device together Exde from Exd Explosion protection according to IECstandards Thermistor-based surface temperature protection T4 for frequency convertor duty Ex tD (DIP) motors, temperature class T 150 C Pt-100-based surface temperature protection T4 for frequency convertor duty. 3-wire system Heating elements 450 451
1)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Light alloy metal fan Cooling method IC418 (without fan) Separate motor cooling (fan axial, N-end) Steel fan Separate motor cooling (fan top, N-end) Stainless steel fan cover
M R NA NA NA NA NA
M R NA NA NA NA NA
M R NA NA NA NA NA
M R NA NA NA NA NA
M R NA NA NA NA NA
M R P P NA NA NA
M R P P NA NA NA
M R P P NA NA NA
M R P P NA P NA
M R P P NA P NA
M R P P P P P
P R P P P P P
P R P P P P P
P R P P P P P
P R P NA P P P
M NA S P P M R R P NA S M M NA
M NA S P P M R R P NA S M M NA
M NA S P P M R R P NA S M M NA
M NA S P P M R R P NA S M M NA
M NA S P P M R R P NA S M M NA
M P S P P M R R P M S M M P
M P S P P M R R P M S M M P
M P S P P M R R P NA S M M P
M P S P P M R R P NA S M M P
M P S P P M R R P NA S M M P
M P S P P P R NA P NA S M M P
P P S P P P R NA R NA S P P P
P P S P P P R NA R NA S P P P
P P S P P P R NA R NA S P P P
P P S P P NA NA NA R NA S P NA P
M M
M M
M M
M M
M M
M M
M M
M M
M M
M M
M M
P P
P P
P P
P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 P P 100 P P 112 P P 132 P P 160 P P 180 P P 200 P P 225 P P 250 P P 280 P P 315 P P 355 P P 400 P P 450 P P
Insulation system 014 405 Winding insulation class H Special winding insulation for frequency converter supply Mounting arrangements 007 008 009 047 066 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3) IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3) IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3) IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5) Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001) & IM B34 (2101) 093 228 229 235 236 245 246 255 256 257 258 259 260 305 309 311 IM 3601 flange mounted, IEC flange, from IM 1001 (B14 from B3) Flange FF 130 Flange FT 130 Flange FF 165 Flange FT 165 Flange FF 215 Flange FT 215 Flange FF 265 Flange FT 265 Flange FF 100 Flange FT 100 Flange FF 115 Flange FT 115 Additional lifting lugs IM 1001 foot mounted, from IM 3001 (B3 from B5) IM 2001 foot/flange mounted, IEC flange, from IM 3001 (B35 from B5) Noise reduction 055 Painting 105 111 114 115 168 303 710 754 Paint thickness report Painting system C3M acc. to ISO 129445:2007 Special paint colour, standard grade Painting system C4M acc. To ISO 12944-5: 2007 Primer paint only Painted insulation layer on inside of the terminal boxes Thermally sprayed zink metallizing with acrylic top coat Painting system C5M acc. to ISO 129445:2007
1)
P P
M M M M M
M M M M M
M M M M M
M M M M M
M M M M M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA P NA P
NA NA P NA P
NA NA P NA P
NA NA P NA P
M M M S M NA NA NA NA M M M M NA M M
M M M S M NA NA NA NA M M M M NA M M
M M M M M S M NA NA NA NA NA NA NA M M
M M M M M S M NA NA NA NA NA NA NA M M
M NA NA M M M M S M NA NA NA NA NA M M
NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S M P P P P P
P S P P P P P P
P S P P P P P P
P S P P P P P P
P S P P P P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 M M P M P M NA P M P M P M M P M M M P P S P R 100 M M P M P M NA P M P M P M M P M M M P P S P R 112 M M P M P M NA P M P M P M M P M M M P P S P R 132 M M P M P M NA P M P M P M M P M M M P P S P R 160 M M P M P M P P M P M P M M P M M M P P S P R 180 M M P M P M P P M P M P M M P M M M P P S P R 200 M M P M P M P P M P M P M M P M M M P P S P R 225 M M P M P M P P M P M P M M P M M M P P S P R 250 M M P M P M P P M P M P M M P M M M P P S P R 280 M NA P M P M P S M P M P M M P M M M P P P S P 315 P NA P P P P P S P P P P P P P P P M P P P S P 355 P NA NA P P P P S P P P P P P P P P M P P P S P 400 P NA NA P P P P S P P P P P P P P P M P P P S P 450 P NA NA P P P NA S P P P P P P P P P M P P NA S P
Protection 005 072 073 158 401 403 434 783 002 004 095 126 135 139 159 161 163 333 069 070 164 165 410 Metal protective roof, vertical motor, shaft down Radial seal at D-end Sealed against oil at D-end Degree of protection IP 65 Protective roof, horizontal motor Degree of protection IP 56 Degree of protection IP 56, open deck Labyrinth sealing at D-end Restamping voltage, frequency and output, continuous duty Additional text on std rating plate (max 12 digits on free text line) Restamping output (maintained voltage, frequency), intermittent duty Tag plate Mounting of additional identification plate, stainless Additional identification plate delivered loose M Additional plate with text Made in .... Additional rating plate delivered loose Frequency converter rating plate. Rating data according to quotation. For export only Two shaft extensions as per basic catalogue. One or two special shaft extensions, standard shaft material Shaft extension with closed key-way Shaft extension with open key-way Stainless steel shaft (standard or nonstandard design) Standards and Regulations 151 540 541 775 778 779 782 788 802
1)
M M P M P M NA P M P M P M
P M M M P P S P R
Design according to SHELL DEP 33.66.05.31-Gen. June 2007 China energy label Inmetro certification Design according to SHELL DEP 33.66.05.31-Gen. January 1999 design. GOST Export/Import Certificate (Russia) SASO Export/Import Certificate (Saudi Arabia) Fulfilling CQST Certification requirements (China) Documentation for Korean KOSHA certification GOST Kazakhstan certified
M P M M P M M M P
M P M M P M M M P
M P M M P M M M NA
M P M M P M M M NA
M P M M P M M M NA
M M P M M M M M P
M M P M M M M M P
M M P M P M M M P
M M P M P M M M P
M M P M P M M M P
P M P M M M M M P
P P P P P P P P P
P P P P P P P P P
P NA P P P P P P NA
NA NA NA NA NA P NA NA NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 P P P NA P P 100 P P P NA P P 112 P P P NA P P 132 P P P NA P P 160 P P P NA P P 180 P P P NA P P 200 P P P NA P P 225 P P P NA P P 250 P P P NA P P 280 P P P P P P 315 P P P P P P 355 P P P P P P 400 P P P P P P 450 P P P P P P
Stator winding temperature sensors 120 121 122 123 125 127 KTY 84-130 (1 per phase) in stator winding Bimetal detectors, break type (NCC), (3 in series), 130 C, in stator winding Bimetal detectors, break type (NCC), (3 in series), 150 C, in stator winding Bimetal detectors, break type (NCC), (3 in series), 170 C, in stator winding Bimetal detectors, break type (NCC), (2x3 in series), 150 C, in stator winding Bimetal detectors, break type (NCC), (3 in series, 130 C & 3 in series, 150 C), in stator winding. 328 435 436 439 441 445 446 502 503 511 PTC - thermistors (3 in series), 120 C, in stator winding PTC - thermistors (3 in series), 130 C in stator winding PTC - thermistors (3 in series), 150 C, in stator winding. PTC - thermistors (2x3 in series), 150 C, in stator winding. PTC - thermistors (3 in series, 130 C & 3 in series, 150 C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Pt-100 2-wire in stator winding, 2 per phase Pt-100 3-wire in stator winding, 1 per phase. Pt-100 3-wire in stator winding, 2 per phase. PTC thermistors (2 x 3 in series), 130 C, in stator winding Terminal box 021 070 157 180 300 380 400 402 418 466 468 469 567 568 728 730
1)
P P P NA P P
M M S M M NA NA NA NA P
M M S M M NA NA NA NA P
M M S M M NA NA NA NA P
M M S M M NA NA NA NA P
M M S M M NA NA NA NA P
M M S M M P P P P P
M M S M M P P P P P
M M S M M P P P P P
M M S M M P P P P P
M M S M M P P P P P
M M S M M P P P P P
P P S P P P P P P P
P P S P P P P P P P
P P S P P P P P P P
P P S P P P P P P P
Terminal box LHS (seen from D-end) Cable entry LHS (seen from D-end) Terminal box degree of protection IP 65 Terminal box RHS (seen from D-end) Increased single core cross section Separate terminal box for temperature detectors, std. material 4 x 90 degr. turnable terminal box Terminal box adapted for Al cables Separate terminal box for auxiliaries, standard material Terminal box at N-end Cable entry from D-end Cable entry from N-end Separate terminal box material: Cast Iron Separate terminal box for heating elements, std. material Standard cable gland, Ex d IIB, armoured cable, double sealing Prepared for NPT cable glands
NA M M NA P NA S NA NA NA M M NA NA P P
NA M M NA P NA S NA NA NA M M NA NA P P
NA M M NA P NA S NA NA NA M M NA NA P P
NA M M NA P NA S NA NA NA M M NA NA P P
NA M M NA P NA S NA NA NA M M NA NA P P
P M M P P P S NA P NA M M S P P P
P M M P P P S NA P NA M M S P P P
NA M M NA P P S NA P P M M S P P P
NA M M NA P P S NA P P M M S P P P
NA M M NA P P S NA P P M M S P P P
NA M M NA P P S S P P M M S P P P
NA P P NA P P S S P P P P S P P P
NA P P NA P P NA S P P R R S P P P
NA P P NA P P NA S P P R R S P P P
NA P P NA P P NA S P P NA NA S P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1) 732 733 734 735 Testing 145 146 148 149 150 222
Variant Standard cable gland, Ex d IIB, armoured cable Standard cable gland, Ex d IIB, nonarmoured cable Standard cable gland, Ex d IIC, armoured cable. Standard cable gland, Ex d IIC, nonarmoured cable. Type test report from a catalogue motor, 400 V 50 Hz Type test with report for one motor from specific delivery batch. Routine test report Test according to separate test specification. Customer witnessed testing. Specify test procedure with other codes. Torque/speed curve, type test and multipoint load test with report for one motor from specific delivery batch.
Frame size 80 M M M M 90 M M M M 100 M M M M 112 M M M M 132 M M M M 160 M M M M 180 M M M M 200 M M M M 225 M M M M 250 M M M M 280 M M M M 315 P P P P 355 P P P P 400 P P P P 450 P P NA NA
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
P P P R P P
P P P R P P
P P P R P P
P P P R P P
Vibration level test Vibration spectrum test for one motor from specific delivery batch. Noise level test for one motor from specific delivery batch Noise spectrum test for one motor from specific delivery batch. Test for one motor from specific delivery batch with ABB frequency converter available at ABB test field. ABB standard test procedure.
M P P R P
M P P R P
M P P R P
M P P R P
M P P R P
M P P P P
M P P P P
M P P P P
M P P P P
M P P P P
M P P P P
P P P P P
P P P P P
P P P P P
P P P P P
Variable speed drives 181 Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. 479 680 701 747
1)
Mounting of other type of pulse tacho with shaft extension, tacho not included. 2048 pulse tacho, Ex d, tD, L&L 841910001 Insulated bearing at N-end. 1024 pulse tacho, Ex d, tD, L&L 841910002
NA NA NA NA
NA NA NA NA
NA NA NA NA
NA NA NA NA
NA NA NA NA
P P NA P
P P NA P
P P NA P
P P NA P
P P NA P
P P M P
P P P P
P P P P
P P P P
P P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
M000269
D GA
M000198
Sizes 80 to 200
Motor size
80 90 100 112 132 160 180 200 225 250 280 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450
1)
IM 1001, IM B3 AND IM 3001, IM B5 D GA F E poles poles poles poles 2 4-8 2 4-8 2 4-8 2 4-8 19 19 21.5 21.5 6 6 40 40 24 24 27 27 8 8 50 50 28 28 31 31 8 8 60 60 28 28 31 31 8 8 60 60 38 38 41 41 10 10 80 80 42 42 45 45 12 12 110 110 48 48 51.5 51.5 14 14 110 110 55 55 59 59 16 16 110 110 55 60 59 64 16 18 110 140 60 65 64 69 18 18 140 140 65 75 69 79.5 18 20 140 140 65 80 69 85 18 22 140 170 65 90 69 95 18 25 140 170 70 100 74.5 106 20 28 140 210 70 100 74.5 106 20 28 140 210 70 100 74.5 106 20 28 140 210 80 110 85 126 22 28 170 210 80 100 85 106 22 28 170 210 - 120 1) 127 1) 32 1) 210 1)
L max poles 2 4-8 340 340 405 405 480 480 480 480 560 560 808 808 826 826 774 774 841 871 875 875 1090 1090 1176 1206 1287 1317 1409 1479 1514 1584 1764 1834 1851 1891 1851 1891 2071 1)
IM 1001, IM B3 A B B'
M000200
HD
IM 3001, IM B5 M N P
Protective roof DS LS 2 160 360 180 430 195 505 195 505 260 590 328 756 359 756 414 844 462 921 506 965 555 1190 624 1290 624 1401 590 1480 590 1530 590 1635 590 1635 700 1860 On request 4-8 360 430 505 505 590 756 756 844 951 965 1190 1320 1431 1550 1600 1705 1705 1900
125 140 160 190 216 254 279 318 356 406 457 508 508 610 610 610 710 686 800
100 100 140 140 140 210 241 267 286 311 368 406 457 500 560 630 900 710 1000
125 125 178 254 279 305 311 349 419 457 508 560 630 710 800 800 1120
50 56 63 70 89 108 121 133 149 168 190 216 216 254 254 254 224 280 250
290 315 335 350 390 495 535 616 663 726 862 929 929 1124 1124 1124 1211 1211 1328
80 90 100 112 132 160 180 200 225 250 280 315 315 355 355 355 400 400 450
165 165 215 215 265 300 300 350 400 500 500 600 600 740 740 740 940 740 1080
130 130 180 180 230 250 250 300 350 450 450 550 550 680 680 680 880 680 1000
200 200 250 250 300 350 350 400 450 550 550 660 660 800 800 800 1000 800 1150
Tolerances: A, B D, DA F, FA H N C, CA 0,8 ISO k6 < 50mm ISO m6 > 50mm ISO h9 -0.5 ISO j6 0.8
Above table gives the main dimensions in mm. For detailed drawings please see our web-pages www.abb.com/motors&generators or contact ABB.
S = Standard ange
M = Modication
NA = Not applicable
M000199
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Stator frame Endshield, D-end Screws for endshield, D-end Endshield, N-end Screws for endshield, N-end Rotor with shaft Key, D-end Terminal box Terminal board Intermediate flange Screws for terminal box cover Outer bearing cover, D-end Valve disc with labyrinth seal, D-end Bearing, D-end Inner bearing cover, D-end Screws for bearing cover, D-end
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Outer bearing cover, N-end Seal, N-end Wave spring (280-315) Coil spring (355-450) Valve disc, N-end Bearing, N-end Inner bearing cover, N-end Screws for bearing cover, N-end Fan Fan cover Screws for fan cover Rating plate Regreasing plate Grease nipple, D-end Grease nipple, N-end SPM nipple, D-end SPM nipple, N-end
M000207
Certicate examples
M000726a
M000725-1
M000725-2
M000727a
Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Forged steel, detachable feet Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6205-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3 6208-2Z/C3 6309/C3 6309/C3 6310/C3 6310/C3
6 terminals for connection with cable lugs (not included) Polyamide. Reinforced with glass fibre. Polypropylene. Reinforced with glass fibre.
Fan cover
Steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors as standard Pressure die-cast aluminum Half key balancing Closed
Stator winding
Rotor winding Balancing Key way Heating elements Drain holes External earthing bolt Enclosure Cooling method
Material
On request
Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Cast iron, EN-GJL-200 or better, integrated with stator Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6312M/C3 6312/C3 6310M/C3 6310/C3 6313M/C3 6313/C3 6312M/C3 6312/C3 6315M/C3 6315/C3 6313M/C3 6313/C3 6316/C3 6316/C3 6316/C3 6319/C3 6316M/C3 6317M/C3 6322/C3 6324/C3 6326M/C3
As standard, locked at D-end Gamma-ring Regreasable bearings As standard Stainless steel Cast iron, EN-GJL-200 or better Cast iron, EN-GJL-200 or better Labyrinth seal
Cover screws material Steel 8.8, zinc electroplated and chromated Connections Cable entries Terminals Fan Material 2xM50x1.5 2xM63x1.5 2xM75x1.5
6 terminals for connection with cable lugs (not included) Polypropylene. Reinforced with glass fibre. Polypropylene reinforced with glass fibre or aluminum.
Fan cover
Hot dip galvanized steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors as standard Pressure die-cast aluminum Half key balancing Closed Open 60 W 120 W 200 W
Stator winding
Rotor winding Balancing Key way Heating elements Drain holes External earthing bolt Enclosure Cooling method
Material
On request
Flameproof motors, Ex de IIB/IIC T4 Gb Totally enclosed squirrel cage three phase low voltage motors, Sizes 80 to 450, 0.55 to 950 kW
Mechanical design
Drain holes
Flameproof Ex de motors are provided without drain holes as standard. Drain holes with certified metal plugs are available as an option. Please see variant code section.
Closed
Open
Bearing seals
The following bearing seals are used as standard, special seals like radial seal are available as option. Please see variant code section.
M000724
Standard delivery 400/690 V (if nothing else informed) Cable entries for supply cables
Motor size Pole number Terminal box type Terminal box opening 80-90 100-132 160-180 200-250 280 315SM, ML 355 SMA, SMB, SMC 355 SMC 355 SMC 355 SMA, SMB 355 ML, LK 355 ML, LK 400 L, LK 400 L, LK 450 2-8 2-8 2-8 2-8 2-8 2-8 2-4 6 8 6-8 2-4 6-8 2-6 8 4-8 25 25 63 160 210 370 750 750 370 370 750 750 750 750 1200 B B B C C D E E D D E E E E E E-D E-D E-D E-D E-D E-D E-2D 1xM25 2xM32 2xM40 2xM50 2xM63 2xM63 2xM63 2xM63 1xM25 2xM32 2xM40 2xM50 2xM63 2xM63 2xM63 2xM63 medium medium large medium large medium 2xlarge 45 adapter Threaded holes Cable gland Cable sealing end unit Cable outer Single core diameter mm 1x10-16 2x16-21 2x18-27 2x26-35 2x32-49 2x32-49 2x48-60 2x48-60 2x32-49 2x32-49 2x60-80 2x48-60 2x60-80 2x48-60 2x60-80 mm2 for rated power 10 10 35 70 2x150 2x240 4x240 4x240 2x240 2x240 4x240 4x240 4x240 4x240 6x240 M5 M5 M6 M10 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 12xM12 Terminal bolt
cross-section size 6 x
Earthings on motor
80-132 160-180 200-250 280-315 355-400 450 Frame M6 M6 M8 M10 M10 M10 Terminal box M6 M6 M8 2xM10 2xM10 4xM12 Terminal box type 25 63 160 210, 370 750 1200
Examples of terminal boxes and connection parts Below pictures show a collection of terminal boxes and connection parts.
M000718
M000719
M000423
M000424
Fig 4. Terminal box for motor sizes 280 to 315 with connection flange and cable glands.
Fig 5. Terminal box for motor sizes 355 to 400, with adapter and cable sealing end unit.
Fig 6. Terminal box for motor sizes 450, with adapter and cable sealing end unit.
M000721
M000722
M000427
M000428
M000429
M000723
M000425
M000720
Adapters
How to order? Check first that the terminal box can allow mounting of the cable and cores (refer to motor type and terminal box type cross reference page 55). If very large cables are used might it be neccesary to use a larger terminal box than standard. Select the right cable gland(s) or cable sealing end unit(s) depending on outer diamater of the cable(s). Select a appropriate adapter and gland(s) and gland plate or cable sealing end unit. Note that turning the terminal box to a non standard position might limit the use of some adapters.
Ordering example Motor Cables 200 kW, 4 pole, 400 V 50 Hz, cables needed: 2 pieces, outer diameter 58 mm, single cross section 185 mm, cables coming from below
Needed one terminal box for anticondensation heaters (220 V) and another for temperature detectors, terminal box material cast iron. Motor Adapter Cable sealing end unit Auxiliaries M3KP 315 MLA 4, B3 D-D (variant code 293) Variant code 278 Variant codes 451, 380, 567, 568
1. Main terminal box and maximum single core cross section Larger than standard single core cross section is available as option according to the table below. Also one size larger terminal box can be selected. Please check also the capacity of the cable entry to make sure the cables fit.
Standard terminal box Terminal box type 25 63 160 210 370 750 1200 Size of opening B B C C D E E Max single core cross section per phase mm2 35 95 120 2 x 240 2 x 300 4 x 500 4 x 500 370 750 1200 D E E Variant code 019 larger terminal box than standard Terminal box type Size of opening Max single core cross section per phase mm2 2 x 240 2 x 300 4 x 500 -
The accessories for using the maximum single core cross sections are not included as standard. For this option please use variant code 300 (Increased single core cross section). Each terminal box has got limited maximum cable entry size, please request if necessary.
M000443
2. Optional adapters To allow easy termination of cables entering the terminal box from above or below is it recommended to use an angle adapter.
These can also be used to allow mounting of several cable sealing end units or gland plates on the terminal box for termination of more cables than one cable sealing end unit or gland plate can allow.
Gland plate or opening for cable sealing end unit Material Notes
Adapter
Variant code
292
M000430
Steel
293
M000431
Steel
294
M000432
Steel
295
M000433
2 pcs D
Steel
296
M000434
3 pcs D
Steel
444
M000435
2 pcs E
Steel
3. Gland plate, maxium size of glands and material Gland plates are delivered blind or drilled and tapped to accomodate glands to suit the cable diameter and amount of glands needed. Standard gland plate material is siluminium, painted steel or stainless steel are available as options.
Size B C D E Maximum size and number of glands, metric 2xM40 2xM90 4xM90 6xM90 3xM32 3xM50 4xM63 7xM63 4xM40 7xM32 7xM50 9xM50
Related variant codes: 729 Cable flanges without holes / Blank gland plates. 730 Prepared for NPT glands 732 Standard cable gland, Ex d IIB, armoured cable. 733 Standard cable gland, Ex d IIB, non-armoured cable. 743 Painted non-drilled flange in steel for cable glands. 744 Stainless steel non-drilled flange for gable glands. 745 Painted steel cable flange equipped with nickle plated brass cable glands. 746 Stainless steel cable flange equipped with nickle plated brass cable glands.
4. Cable glands and cable sealing end units Cable glands Table below shows the selction of cable gland types and possible cable outer diameter of each size.
Outer diameter, mm Variant code 745 Painted steel ange equipped with brass cable glands Motor sizes 80-450: M20 M25 M32 M40 M50 M63 M75 M90
Variant code 737 Standard cable gland Ex e with clamping device acc. to EN-Standards
Cable sealing end unit As an alternative to flanges and cable glands, cable sealing units can be used. These allow more space for spreading the cores for easy terminating on the terminals. Cable sealing end units have rubber sealed entries for one or two main cables. In addition are there two plugged M20 holes for auxillary cables.
Accessories Variant code Opening towards terminal box Cable outer diameter mm Cable entry auxiliary cable Variant code 704; EMC cable gland Variant code 231; Clamping device
277
M000436
1 or 2 pcs 48-60 mm *)
Optional
Optional
278
M000437
1 or 2 pcs 48-60 mm *)
Optional
Optional
279
M000438
1 or 2 pcs 60-80 mm *)
Optional
Optional
*) Depending on how the cable seal inside the cable sealing end unit is used also 40-52 mm is available.
M000437
5. Auxiliary terminal box It's possible to equip the motors from frame size 160 upwards with one or several auxiliary terminal boxes for connection of auxiliaries like heaters or temperature detectors. The standard auxiliary terminal box is made of aluminum and equipped with M20 glands for entry of the connection cables. As an option cast iron terminal box is available. In motor sizes 160 to 180 the material of auxiliary terminal box is cast iron. Connection terminals are spring loaded type for quick and easy connection. These are suitable for up to 2.5 mm wires. Auxiliary terminal boxes are equipped with an earthing terminal. As standard the first auxiliary terminal box is located on RHS seen from D-end. Small, aluminum auxiliary terminal box (80 x 125 mm, for max 12 wires) Earthing size M4
Related variant codes: 418 Separate terminal box for auxiliaries, standard material (all connections of temperature detectors and heaters will be put in same box) 380 Separate terminal box for temperature detectors, standard material 568 Separate terminal box for heating elements, standard material 569 Separater terminal box for brakes, standard material 567 Separate terminal box material: Cast iron
Large, aluminum auxiliary terminal box (80 x 250 mm, for max 30 wires) Earthing M4
Cast iron auxiliary terminal box (211 x 188 mm, for max 30 wires) Earthing M6
M000439
M000440
Standard cable entry size M20. Number of entries depends on the terminal box type and number of selected auxiliaries.
M000441
M000368
M000365
M000205
M000206
M000369
M000368
Ex de - M3KP
Motor size 80-132 160-180 200-250 280 315, 355 355, 400 450 Terminal box 25 63 160 210 370 750 1200 A1 202 234 352 416 451 686 1000 B1 188 234 319 306 347 413 578 H1 66 68 184 177 200 219 285
M000331
If the radial force is applied between points X0 and X max, the permissible force FR can be calculated from the following formula:
Cast iron motors Permissible radial forces according to L10 princible Flameproof motor Ex de IIB/IIC, motor sizes 80 to 132
Motor size 80 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 Poles Length of shaft extention E (mm) 40 40 40 40 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80 80 Ball bearings 40,000 hours FX0 (N) FXmax (N) 619 780 893 983 561 803 919 1011 553 1050 1267 1395 553 1050 1267 1394 1354 1772 2028 2234 524 663 759 834 473 677 775 853 457 868 1047 1153 457 868 1047 1152 1112 1454 1665 1833
90
100
112
132
M000145
Cast iron motors Permissible radial forces according to L10 princible Flameproof motors Ex de IIB/IIC, motor sizes 160 to 450
Motor size Poles Lengt of shaft extension E (mm) 110 110 110 110 110 110 110 110 110 110 110 110 110 140 140 140 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 210 140 210 140 210 170 210 170 210 210 Ball bearings IIB 1) 40,000 hours 160 ML_ 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 2 4-8 2 4-8 2 4-8 2 4-8 4-8 FX0 (N) 2530 3180 3650 4020 2900 3660 4190 4620 3830 4820 5520 6080 4350 5490 6280 6920 5390 6790 7760 8550 5840 7260 8300 9150 5810 9030 10310 11370 5850 9000 10270 11330 5790 11930 5770 11980 5500 12050
2) 2) 2) 2) 2)
180 ML_
200 ML_
225 SM_
250 SM_
280 SM_
315 SM_
315 ML_
355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
1) 2)
FXmax (N) 2120 2670 3040 3040 2440 3080 3520 3880 3150 3980 4550 5000 3660 2800 2800 2800 4350 5480 6270 6900 4900 6110 6980 7700 4960 7470 8530 9410 5080 7620 8500 9380 5090 9890 5120 10090 5000 10450
2) 2) 2) 2) 2)
FX0 (N) 2530 3180 3650 4020 2900 3660 4190 4620 3830 4820 5520 6080 4350 5490 6280 6920 5390 6790 3000 3000
2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2)
FXmax (N) 2120 2670 3040 3040 2440 3080 3520 3880 3150 3980 4550 5000 3660 2800 2800 2800 2900 2800 2800 2800
2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2) 2)
FX0 (N) 6400 7600 7600 7600 6970 8500 8500 8500 9510 11710 13230 14420 11650 14340 16190 17300 15420 18980 21000 21000 16550 20100 22690 24740 16540 26590 39030 32740 16710 26580 30010 32730 NA NA NA NA NA NA NA NA NA NA NA
FXmax (N) 1800 1800 1800 1800 2700 2700 2700 2700 7000 7000 7000 7000 7000 7200 7200 7200 6700 9200 9200 9200 6000 9200 9200 9200 6000 9600 9600 9600 5850 13040 10040 9940 NA NA NA NA NA NA NA NA NA NA NA
FX0 (N) 6400 7600 7600 7600 6970 8500 8500 8500 9510 11710 13230 14420 9300 9300 9300 9300 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
FXmax (N) 1800 1800 1800 1800 2700 2700 2700 2700 4200 4200 4200 4200 3000 2200 2200 2200 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
IIB on request, requires special construction. Flameproof motor Ex de IIB/IIC - sizes 280-315 on allowed for direct coupling applications.
FAD
Cast iron motors, sizes 80 to 450 Mounting arrangement IM B3
Motor size 40,000 hours 2-pole FAD N 660 740 1100 1100 1530 2050 2570 3300 3710 5200 4870 4780 4730 1660 1570 1440 810 810 NA 4-pole FAD N 820 900 1320 1320 1870 2620 3230 4180 4690 6400 6140 7170 7080 5760 5640 5460 4250 4250 4450
FAZ
80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
1)
FAZ N 300 220 220 220 500 1440 1470 2040 2240 2100 2870 2780 2730 5460 5370 5240 5810 5810 NA
FAZ N 460 380 430 430 840 2010 2130 2920 3230 3310 4140 5170 5080 9560 9440 9260 10250 10250 10450
6-pole FAD N 940 1010 1480 1480 2110 3060 3730 4820 5410 7260 7040 8210 8100 7060 6880 6680 5510 5410 5630
M000022
FAZ N 580 490 590 590 1080 2440 2630 3560 3940 4160 5040 6210 6100 10860 10680 10480 11510 11410 11630
8-pole FAD N 1030 1110 1610 1610 2320 3410 4140 5360 6010 8000 7840 9180 9060 8290 8100
1)
FAZ N 670 590 720 720 1280 2790 3040 4100 4540 4900 5840 7180 7070 12090 11900
1)
6630
1)
12630
1)
6920
12920
On request
FAZ
M000023
FAD
Mounting arrangement IM V1
Motor size 40,000 hours 2-pole FAD N 690 780 1180 1180 1700 2440 3120 3960 4570 6240 6440 6950 7280 5330 5860 6600 8010 8010 NA 4-pole FAD N 860 950 1430 1430 2080 3160 3980 5030 5770 7720 8170 9820 10300 11110 11810 12850 13680 13680 17940 6-pole FAD N 970 1080 1600 1600 2380 3590 4490 5820 6660 8930 9580 11760 12330 13720 14718 15800 16610 17180 22090 8-pole FAD N 1070 1170 1730 1730 2580 3950 4890 6370 7280 9690 10380 12740 13310 14980 15970
1)
80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
1)
FAZ N 280 190 170 170 390 1180 1100 1590 1650 1380 1780 1270 940 2890 2360 1630 730 730 NA
FAZ N 440 340 360 360 690 1650 1630 2340 2500 2410 2760 3350 2870 5820 5130 4080 3650 3650 910
FAZ N 550 450 510 510 900 2090 2130 2890 3100 3047 3340 3810 3240 6270 5280 4190 3840 3270 150
FAZ N 650 540 640 640 1110 2430 2550 3430 3700 3780 4150 4780 4210 7530 6540
1)
On request
Rating plates
The rating plates are in table form giving values for speed, current and power factor for three voltages: 400V-415V-690V as standard. Other voltage and frequency combinations are possible and can be ordered with variant codes 002 or 209. Please see Variant code section. The following information will be shown on the motor rating plate: Lowest nominal efficiency at 100 %, 75 % and 50 % rated load Efficiency level Year of manufacture Type of protection Apparatus group Temperature class Identification number of the certification body Certificate number (both ATEX and IECEx are stamped on the rating plate as standard)
M000732
Position 11 - (Dash)
Position 14
Generation code G/H Generation code is followed by variant codes according to the hazardous area, see below and on corresponding pages with variant codes: 461 Ex d(e) design, Group IIC
IE2
Current
Torque Tb TN 3.8 3.2 3.5 3.5 3.0 3.7 3.3 3.6 3.1 3.5 3.4 3.1 3.2 3.2 3.0 3.1 3.0 2.9 3.0 3.0 3.0 3.0 3.3 3.0 3.0 2.9 2.9 3.9 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.1 3.6 3.1 3.0 3.2 3.2 3.1 3.0 Moment Sound of inertia pressure J = 1/4 GD 2 Weight level LPA kgm 2 kg dB 0.0006 0.0007 0.001 0.0014 0.0036 0.0043 0.009 0.012 0.043 0.052 0.062 0.089 0.15 0.19 0.26 0.49 0.8 0.9 1.2 1.4 1.7 2.1 3 3.4 3.6 4.1 4.3 4.8 7.9 7.9 8.2 8.2 9.3 9.3 0.07 0.13 0.13 0.22 0.29 0.31 0.57 0.59 1.15
Is / IN
Product code 400 V 50 Hz 3GKP 081 310-H 3GKP 081 320-H 3GKP 091 010-H 3GKP 091 030-H 3GKP 101 510-H 3GKP 111 320-H 3GKP 131 220-H 3GKP 131 240-H 3GKP 161 410-H 3GKP 161 420-H 3GKP 161 430-H 3GKP 181 410-H 3GKP 201 410-G 3GKP 201 430-G 3GKP 221 220-G 3GKP 251 210-G 3GKP 281 210-G 3GKP 281 220-G 3GKP 311 210-G 3GKP 311 220-G 3GKP 311 230-G 3GKP 311 410-G 3GKP 351 210-G 3GKP 351 220-G 3GKP 351 230-G 3GKP 351 410-G 3GKP 351 420-G 3GKP 351 810-G 3GKP 401 510-G 3GKP 401 810-G 3GKP 401 520-G 3GKP 401 820-G 3GKP 401 530-G 3GKP 401 830-G 400 V 50 Hz 3GKP 161 440-H 3GKP 181 420-H 3GKP 181 430-H 3GKP 201 450-G 3GKP 221 230-G 3GKP 221 240-G 3GKP 251 220-G 3GKP 251 230-G 3GKP 281 230-G
3/4 1/2 Power I N Is TN Tl Speed Full load load load factor r/min 100% 75% 50% cos A IN Nm TN CENELEC-design 2861 80.1 79.4 76.2 0.87 1.55 7.3 2.5 3.7 2833 81.6 82.2 80.6 0.87 2.2 5.9 3.7 3.0 2881 81.9 82.1 80.1 0.88 3 6.7 4.9 3.0 2877 84.5 85.0 83.8 0.89 4.2 7.8 7.3 2.7 2896 86.0 86.4 84.9 0.90 5.5 6.8 9.8 2.2 2891 86.0 86.5 85.3 0.89 7.5 7.8 13.2 3.6 2905 87.0 87.2 85.8 0.90 10.1 6.9 18 2.4 2914 88.3 88.7 87.6 0.90 13.6 7.6 24.5 2.8 2931 90.1 90.5 89.6 0.89 19.7 7.2 35.8 2.6 2929 91.2 91.9 91.4 0.89 26.6 7.2 48.9 3.0 2934 91.8 92.2 91.8 0.90 32.3 7.5 60.2 2.8 2938 91.7 92.2 91.7 0.90 38.4 7.0 71.5 2.5 2956 93.2 93.6 93.0 0.88 52.7 7.4 96.9 3.0 2954 93.6 94.0 93.4 0.89 64.1 7.5 119 2.8 2968 93.9 93.8 92.9 0.87 79.5 7.2 144 2.7 2975 94.3 94.1 93.0 0.89 94.5 7.8 176 2.4 2978 94.3 94.1 92.8 0.88 130 7.6 240 2.1 2976 94.6 94.5 93.5 0.90 152 7.4 288 2.1 2982 94.9 94.4 92.9 0.86 194 7.6 352 2.0 2982 95.1 94.8 93.6 0.88 227 7.4 422 2.2 2981 95.4 95.2 94.2 0.89 271 7.5 512 2.3 2980 95.7 95.7 94.9 0.90 335 7.7 640 2.6 2984 95.7 95.5 94.5 0.89 423 7.7 800 2.1 2980 95.7 95.7 95.1 0.89 533 7.0 1009 2.1 2984 95.7 95.7 95.2 0.88 608 7.2 1136 2.2 2982 96.9 96.6 95.9 0.88 677 7.1 1280 2.3 2983 97.1 97.0 96.4 0.90 743 7.9 1440 2.2 2982 96.9 96.9 96.5 0.90 827 7.5 1601 2.0 2988 97.2 97.2 96.6 0.89 934 7.8 1789 2.1 2988 97.2 97.2 96.6 0.89 934 7.8 1789 2.1 2987 97.4 97.4 96.9 0.89 1048 7.8 2014 2.2 2987 97.4 97.4 96.9 0.89 1048 7.8 2014 2.2 2987 97.5 97.4 97.0 0.89 1180 7.8 2269 2.6 2987 97.5 97.4 97.0 0.89 1180 7.8 2269 2.6 High-output design 2929 91.2 91.6 91.0 0.90 38.6 7.3 71.7 2.7 2943 92.5 93.0 92.6 0.90 52 6.8 97.3 2.3 2947 92.8 93.0 92.5 0.90 63.9 7.9 119 2.9 2944 93.3 93.6 93.0 0.88 79.1 7.3 145 2.9 2965 93.9 93.9 92.9 0.88 96 7.1 177 2.6 2966 93.9 93.7 92.6 0.86 119 7.4 215 2.8 2969 94.0 94.0 93.2 0.89 129 7.9 241 2.6 2965 94.0 94.2 93.7 0.90 153 7.7 289 2.6 2978 95.1 95.0 94.2 0.90 185 7.9 352 2.4
The two bullets in the product code indicate choice of mounting
28 30 41 44 61 64 92 100 207 216 227 259 290 320 380 440 645 685 900 960 1045 1210 1630 1710 1780 2030 2110 2350 3070 3070 3170 3170 3420 3420 233 292 292 325 400 410 480 490 745
59 59 61 61 65 65 71 71 71 71 69 69 74 75 76 75 77 77 78 78 78 78 83 83 83 83 83 83 82 82 82 82 82 82 77 78 77 79 80 78 80 80 77
Temperature rise class F Efciency class IE1 3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
= Starting current
4)
Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045 Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
5)
IE2
Current
Torque Tb TN 2.7 2.7 3.5 3.0 3.3 3.4 3.8 3.5 3.7 3.5 3.5 3.1 3.0 2.8 2.9 2.7 3.1 2.8 2.7 2.5 2.7 2.9 2.9 2.7 2.8 2.7 2.6 2.9 3.0 2.8 2.8 2.9 2.9 3.0 3.0 3.0 3.0 3.0 3.5 3.6 3.2 3.2 2.9 2.9 3.2 3.5 3.0 Moment Sound of inertia pressure J = 1/4 GD2 Weight level L PA kgm2 kg dB 0.001 0.0012 0.002 0.003 0.0075 0.0081 0.013 0.023 0.034 0.096 0.13 0.19 0.21 0.34 0.42 0.49 0.72 1.25 1.5 2.3 2.6 2.9 3.5 5.9 6.9 7.2 8.4 8.4 10 15 15 16 16 17 17 23 25 30 0.13 0.13 0.248 0.34 0.55 0.55 0.88 0.98 1.85 29 31 42 44 51 63 72 102 105 226 249 271 279 320 370 405 430 645 685 920 980 1020 1180 1640 1810 1850 2170 2170 2530 3040 3040 3420 3420 3520 3520 4050 4350 4700 249 249 298 320 425 425 485 510 745 59 59 54 54 52 52 52 60 60 62 61 62 62 61 67 67 66 68 68 70 70 70 70 74 74 78 78 78 78 78 78 78 78 78 78 85 85 85 68 68 66 73 68 74 73 74 68
Product code 400 V 50 Hz 3GKP 082 310-H 3GKP 082 320-H 3GKP 092 010-H 3GKP 092 030-H 3GKP 102 510-H 3GKP 102 520-H 3GKP 112 330-H 3GKP 132 220-H 3GKP 132 240-H 3GKP 162 430-H 3GKP 162 450-H 3GKP 182 410-H 3GKP 182 420-H 3GKP 202 420-G 3GKP 222 220-G 3GKP 222 230-G 3GKP 252 210-G 3GKP 282 210-G 3GKP 282 220-G 3GKP 312 210-G 3GKP 312 220-G 3GKP 312 230-G 3GKP 312 410-G 3GKP 352 210-G 3GKP 352 220-G 3GKP 352 230-G 3GKP 352 410-G 3GKP 352 420-G 3GKP 352 810-G 3GKP 402 510-G 3GKP 402 810-G 3GKP 402 520-G 3GKP 402 820-G 3GKP 402 530-G 3GKP 402 830-G 3GKP 452 510-G 3GKP 452 520-G 3GKP 452 530-G 400 V 50 Hz 3GKP 162 460-H 3GKP 162 470-H 3GKP 182 430-H 3GKP 202 430-G 3GKP 222 240-G 3GKP 222 250-G 3GKP 252 220-G 3GKP 252 230-G 3GKP 282 230-G
3/4 1/2 Power IN Is TN Tl Speed Full load load load factor r/min 100% 75% 50% cos A IN Nm TN CENELEC-design 1421 76.6 76.6 73.7 0.73 1.41 4.9 3.6 2.3 1412 80.4 80.5 78.4 0.76 1.77 5.2 5 2.2 1432 83.3 83.3 80.7 0.77 2.4 5.9 7.3 2.8 1431 83.2 82.8 80.4 0.79 3.2 6.5 10 2.3 1441 84.7 85.6 84.8 0.86 4.3 7.0 14.5 2.7 1442 86.5 87.2 86.3 0.83 6 7.3 19.8 2.7 1458 88.2 87.8 85.6 0.78 8.3 8.7 26.1 3.0 1458 88.5 88.7 87.2 0.79 11.3 7.4 36 3.0 1460 89.1 89.1 87.6 0.75 16.1 6.8 49 3.3 1470 91.2 91.5 90.6 0.82 21.2 7.8 71.4 3.0 1467 92.0 92.4 92.1 0.84 28 7.8 97.6 3.0 1474 91.6 92.0 91.2 0.83 35.1 7.2 119 2.6 1471 91.6 92.4 92.2 0.83 41.7 6.8 142 2.5 1475 93.6 94.0 93.7 0.85 54.4 7.4 194 3.0 1480 93.6 93.9 93.4 0.85 67.1 7.6 238 3.2 1477 94.1 94.6 94.4 0.88 78.4 7.6 290 3.2 1479 94.3 94.3 93.6 0.84 100 7.2 355 2.5 1484 94.5 94.5 93.9 0.85 134 6.9 482 2.5 1483 94.7 94.8 94.4 0.86 159 7.2 579 2.5 1487 95.1 95.1 94.3 0.86 194 7.2 706 2.0 1487 95.4 95.4 94.7 0.86 232 7.1 847 2.3 1487 95.6 95.6 95.1 0.85 284 7.2 1027 2.4 1486 95.6 95.6 95.3 0.86 351 7.2 1285 2.5 1488 95.9 95.9 95.5 0.86 437 7.1 1604 2.3 1488 95.9 95.9 95.6 0.86 551 7.3 2021 2.3 1487 95.9 95.9 95.7 0.86 621 6.8 2279 2.4 1489 96.3 96.3 95.9 0.85 705 6.8 2565 2.3 1490 96.8 96.8 96.3 0.86 780 6.9 2884 2.3 1490 97.0 97.0 96.5 0.86 865 6.8 3204 2.0 1491 96.8 96.8 96.3 0.85 982 7.4 3586 2.4 1491 96.8 96.8 96.3 0.85 982 7.4 3586 2.4 1491 97.0 97.0 96.5 0.87 1077 7.6 4034 2.2 1491 97.0 97.0 96.5 0.87 1077 7.6 4034 2.2 1491 97.1 97.1 96.6 0.86 1227 7.6 4547 2.4 1491 97.1 97.1 96.6 0.86 1227 7.6 4547 2.4 1491 96.7 96.6 96.0 0.85 1369 7.1 4995 1.4 1492 96.8 96.7 96.2 0.85 1526 7.2 5568 1.4 1491 96.9 96.9 96.5 0.85 1664 7.3 6084 1.4 High-output design 1469 91.7 92.1 91.4 0.83 35 7.8 120 3.2 1466 90.8 91.1 90.4 0.81 43.1 7.9 143 3.3 1473 92.2 92.3 91.6 0.81 57.9 7.1 194 2.8 1475 93.0 93.1 92.3 0.82 70 7.5 239 3.5 1483 94.3 94.5 93.9 0.83 101 7.4 354 3.4 1477 93.5 93.7 93.0 0.84 113 7.7 400 3.5 1476 94.3 94.5 94.2 0.86 133 7.6 485 2.8 1477 94.1 94.4 94.0 0.85 155 7.8 556 2.9 1485 95.1 95.2 94.7 0.86 194 7.6 707 3.0
The two bullets in the product code indicate choice of mounting
Temperature rise class F Efciency class IE1 For 400-415 V 50 Hz ( 380 V 50 Hz voltage code B )
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
IE2
Current
Torque Tb TN 3.6 2.9 2.8 2.4 2.9 2.8 3.0 3.4 3.4 3.0 3.5 3.2 3.1 3.2 3.0 2.9 2.5 2.6 2.8 2.8 2.9 3.0 2.6 2.7 2.9 2.7 2.9 2.7 2.7 2.8 2.8 2.7 2.7 2.8 2.8 2.9 2.9 3.2 3.9 3.2 3.4 2.8 2.8 2.7 Moment Sound of inertia pressure 2 J = 1/4 GD Weight level LPA kgm 2 kg dB 0.0022 0.0022 0.0037 0.0048 0.012 0.014 0.032 0.034 0.039 0.088 0.126 0.25 0.37 0.43 0.64 1.16 1.85 2.2 3.2 4.1 4.9 5.8 7.9 9.7 11.3 13.5 15.5 17 17 20.5 20.5 22 22 24 24 31 37 41 0.126 0.25 0.49 0.75 1.49 2.85
Is / IN
Product code 400 V 50 Hz 3GKP 083 310-H 3GKP 083 320-H 3GKP 093 010-H 3GKP 093 030-H 3GKP 103 510-H 3GKP 113 320-H 3GKP 133 220-H 3GKP 133 230-H 3GKP 133 240-H 3GKP 163 410-H 3GKP 163 420-H 3GKP 183 420-H 3GKP 203 410-G 3GKP 203 420-G 3GKP 223 220-G 3GKP 253 210-G 3GKP 283 210-G 3GKP 283 220-G 3GKP 313 210-G 3GKP 313 220-G 3GKP 313 230-G 3GKP 313 410-G 3GKP 353 210-G 3GKP 353 220-G 3GKP 353 230-G 3GKP 353 420-G 3GKP 353 810-G 3GKP 403 510-G 3GKP 403 810-G 3GKP 403 520-G 3GKP 403 820-G 3GKP 403 530-G 3GKP 403 830-G 3GKP 403 540-G 3GKP 403 840-G 3GKP 453 510-G 3GKP 453 520-G 3GKP 453 530-G 400 V 50 Hz 3GKP 163 430-H 3GKP 183 430-H 3GKP 203 430-G 3GKP 223 230-G 3GKP 253 220-G 3GKP 283 230-G
3/4 1/2 Power I N Is TN Tl Speed Full load load load factor r/min 100% 75% 50% cos A IN Nm TN CENELEC-design 953 72.6 70.3 64.6 0.64 1.14 4.8 3.7 3.4 938 72.9 71.7 67.0 0.70 1.55 4.3 5.5 2.8 946 77.9 77.1 73.4 0.69 2 4.9 7.5 2.1 933 78.5 78.8 76.3 0.71 2.8 4.7 11.2 1.8 951 80.1 80.0 77.4 0.74 3.6 4.2 15 2.3 950 82.0 82.5 80.6 0.76 5 5.9 22.1 2.2 961 83.3 83.0 80.4 0.77 6.7 6.1 29.8 2.1 964 84.6 84.3 81.8 0.74 9.2 6.6 39.6 2.3 967 87.6 87.5 85.7 0.72 12.5 6.9 54.3 2.3 965 87.2 88.4 88.2 0.81 15.3 6.5 74.2 1.9 972 90.1 90.8 90.4 0.81 21.7 7.8 108 2.3 972 90.4 91.0 90.4 0.82 29.2 7.2 147 1.9 983 90.9 91.1 90.2 0.82 35.8 7.1 179 3.2 983 91.6 91.9 91.0 0.82 42.2 7.5 213 3.2 985 92.2 92.6 92.2 0.82 57.2 7.4 290 3.4 987 93.1 93.4 92.8 0.81 70.8 7.2 357 3.2 990 93.4 93.6 93.1 0.84 82.7 7.0 434 2.5 990 93.8 94.0 93.3 0.84 100 7.0 530 2.7 992 94.4 94.4 93.5 0.82 139 7.4 721 2.4 992 94.8 94.8 94.2 0.84 163 7.5 866 2.4 991 95.0 95.0 94.6 0.83 201 7.4 1059 2.5 991 95.3 95.4 94.9 0.83 240 7.5 1271 2.7 993 95.4 95.4 94.8 0.83 291 7.0 1538 2.0 993 95.7 95.7 95.1 0.84 359 7.2 1923 2.2 993 95.7 95.7 95.1 0.83 454 7.4 2404 2.6 992 95.7 95.7 95.2 0.83 572 7.0 3032 2.5 992 95.7 95.7 95.1 0.83 645 7.6 3417 2.7 993 96.2 96.3 95.8 0.82 731 7.1 3846 2.3 993 96.2 96.3 95.8 0.82 731 7.1 3846 2.3 994 96.6 96.6 96.1 0.82 819 7.4 4323 2.4 994 96.6 96.6 96.1 0.82 819 7.4 4323 2.4 993 96.6 96.7 96.2 0.83 900 7.2 4808 2.5 993 96.6 96.7 96.2 0.83 900 7.2 4808 2.5 993 96.9 96.9 96.4 0.85 981 7.4 5385 2.4 993 96.9 96.9 96.4 0.85 981 7.4 5385 2.4 994 96.6 96.6 96.2 0.83 1098 7.1 5860 1.4 995 96.7 96.7 96.2 0.84 1208 7.6 6526 1.5 995 96.7 96.7 96.3 0.83 1366 7.8 7293 1.6 High-output design 969 89.2 89.4 88.0 0.75 30.2 7.9 137 2.8 975 90.1 90.2 88.7 0.74 40 7.2 181 2.0 983 91.6 91.7 90.5 0.80 59 7.5 291 3.5 983 92.1 92.5 92.1 0.83 69.8 7.1 359 3.0 986 93.1 93.3 92.6 0.82 85 7.2 435 3.3 990 94.2 94.5 94.1 0.84 136 7.3 723 2.8
The two bullets in the product code indicate choice of mounting
29 29 41 44 60 63 96 98 105 220 247 298 280 300 365 435 625 665 850 950 1020 1170 1550 1710 1850 2210 2530 3020 3020 3270 3270 3420 3420 3520 3520 4150 4500 4800 247 298 320 395 480 745
50 50 44 44 54 54 57 57 62 57 65 58 66 61 61 66 66 66 70 70 70 68 75 75 75 75 75 76 76 76 76 76 76 77 77 81 81 81 64 61 65 64 65 66
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
3/4 1/2 Power I N Is TN Tl Speed Full load load load factor r/min 100% 75% 50% cos A IN Nm TN CENELEC-design 720 61.0 56.4 48.3 0.48 0.88 3.3 2.3 3.7 705 63.8 61.1 54.6 0.58 0.97 3.2 3.3 2.6 696 67.0 67.0 63.1 0.63 1.26 3.0 5 2.0 695 68.7 68.5 64.4 0.61 1.89 3.1 7.5 2.2 720 75.9 74.1 69.1 0.59 2.4 3.8 9.9 2.0 717 76.4 74.9 70.2 0.57 3.6 3.7 14.6 2.1 713 77.2 76.4 72.4 0.59 4.7 3.5 20 2.0 720 80.1 79.8 76.7 0.65 6 4.7 29.1 2.0 710 79.9 81.5 80.6 0.70 7.7 4.1 40.3 1.7 722 86.7 87.4 86.6 0.71 9.3 5.4 52.9 1.7 723 86.8 87.6 86.8 0.71 12.8 5.8 72.6 1.9 718 85.5 86.3 85.5 0.70 18 5.7 99.7 2.1 723 88.3 89.2 88.7 0.72 24.9 5.7 145 1.7 734 89.9 90.3 89.6 0.79 30.4 7.0 195 2.4 734 90.0 90.3 89.3 0.74 40 6.1 240 2.2 732 90.6 91.2 90.6 0.77 45.5 6.5 287 2.2 735 91.4 91.2 90.7 0.78 60.7 6.7 389 2.0 741 92.7 92.7 91.6 0.78 73.8 7.3 476 1.7 741 93.2 93.2 92.2 0.78 89.3 7.6 579 1.8 742 93.4 93.5 92.7 0.81 104 7.1 707 1.6 741 93.7 93.9 93.4 0.82 140 7.1 966 1.7 741 94.0 94.2 93.6 0.82 168 7.4 1159 1.8 740 94.0 94.3 94.0 0.83 203 7.3 1419 1.8 744 94.7 94.7 94.0 0.80 251 7.5 1694 1.5 744 95.2 95.2 94.5 0.80 303 7.6 2053 1.6 743 95.3 95.4 94.8 0.80 378 7.4 2570 1.6 743 95.4 95.5 95.0 0.80 472 7.5 3213 1.6 744 96.1 96.2 95.8 0.81 584 7.0 4043 1.2 744 96.1 96.2 95.8 0.81 584 7.0 4043 1.2 743 96.2 96.3 96.1 0.83 641 6.8 4562 1.2 743 96.2 96.3 96.1 0.83 641 6.8 4562 1.2 744 96.3 96.4 96.0 0.82 731 7.4 5134 1.3 744 96.3 96.4 96.0 0.82 731 7.4 5134 1.3 744 95.9 96.1 95.8 0.82 789 6.2 5519 1.0 744 96.0 96.2 95.8 0.82 861 6.6 6032 1.1 745 96.1 96.2 95.8 0.81 982 7.3 6793 1.3 745 96.3 96.3 95.9 0.80 1124 7.9 7690 1.4 CENELEC-design 734 89.8 90.2 89.6 0.80 37.1 6.9 240 2.2 731 90.7 91.5 91.3 0.78 61.2 6.3 391 2.3 737 92.2 91.7 91.0 0.78 74.2 7.5 479 2.3 741 93.4 93.5 92.8 0.80 106 7.9 708 1.9
29 29 41 43 60 60 64 98 100 245 245 245 292 295 350 365 435 625 665 850 950 1020 1170 1550 1710 1850 2210 3020 3020 3320 3320 3520 3520 3750 4000 4350 4800 315 390 480 745
36 36 36 36 54 54 54 59 59 59 53 55 63 56 55 56 56 65 65 62 62 64 72 69 69 69 72 71 71 71 71 71 71 80 80 80 80 57 59 59 65
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
Bearings and Lubrication 036 037 040 041 043 058 107 128 129 130 194 433 506 654 795 796 797 798 799 800 Brakes 412 Built-on brake. R R R R R R R R NA NA NA NA NA NA NA Transport lock for bearings. Roller bearing at D-end. Heat resistant grease. Bearings regreasable via grease nipples. SPM compatible nipples for vibration measurement Angular contact bearing at D-end, shaft force away from bearing. Pt100 2-wire in bearings. Double Pt100, 2-wire in bearings Double Pt100, 3-wire in bearings Pt100 3-wire in bearings. 2Z bearings greased for life at both ends. Outlet grease collector Nipples for vibration measurement: SKF Marlin Quick Connect stud CMSS-2600-3 Provision for vibration sensors (M8x1) Lubrication information plate Grease nipples JIS B 1575 Pt 1/8 Type A Stainless steel SPM Nipples Stainless steel grease nipples Grease nipples flat type DIN 3404, thread M10x1 Grease nipples JIS B 1575 Pt 1/8" pin type NA NA NA NA NA P P P P P P P P P P NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA P M P P P M P M P P P M P M P P P M P M P P P M P M P P P M P S P P P M P S P P P P P S P P P P P S P P P P P S P P P P NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA P P P P M NA P P P P P M NA P P P P P M NA P P P P P M NA P P P P P M NA P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P NA NA NA NA NA NA NA NA NA NA P P P P P NA NA S NA NA NA NA S NA NA NA NA S NA NA NA NA S NA NA NA NA S NA NA NA M P S S NA M P S S NA M P S S NA M P S S NA M P S S P M P S S P P P S S P NA P S S P NA P S S P NA P S S
Branch standard designs 178 204 209 396 Stainless steel / acid proof bolts. Jacking bolts for foot mounted motors. Non-standard voltage or frequency, (special winding). Motor designed for ambient temperature -20 C to -40 C, wtih space heaters (code 450/451 must be added).
1)
S NA P P
S NA P P
S NA P P
S NA P P
S NA P P
M P P P
M P P P
M P P P
M P P P
M P P P
M P P P
P P P P
P S P P
P S P P
P S P NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 P 100 P 112 P 132 P 160 P 180 P 200 P 225 P 250 P 280 P 315 P 355 P 400 P 450 NA
397
Motor designed for ambient temperature -40 C to -55 C, wtih space heaters (code 450/451 must be added).
Motor designed for ambient temperature -20 C to -40 C. Motor designed for ambient temperature -40 C to -55 C. Corrosion protected stator and rotor core. Special design shaft upwards (V3, V36, V6) for outdoor mounting.
P P S P
P P S P
P P S P
P P S P
P P S P
P P S P
P P S P
P P S P
P P S P
P P S P
P P P R
P P P R
P P P NA
P P P NA
NA NA P NA
Cooling system 044 Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors. 045 Unidirectional fan for reduced noise level. Rotation counter clockwise seen from D-end. Available only for 2-pole motors. 068 075 183 206 422 514 791 Coupling 035 Assembly of customer supplied couplinghalf. Documentation 141 Binding dimension drawing. M M M M M M M M M M M P P P P NA NA NA NA NA NA NA NA NA NA P P P P P Light alloy metal fan Cooling method IC418 (without fan). Separate motor cooling (fan axial, N-end). Steel fan Separate motor cooling (fan top, N-end). Separate motor cooling (fan on top) Stainless steel fan cover M R NA NA NA NA NA M R NA NA NA NA NA M R NA NA NA NA NA M R NA NA NA NA NA M R NA NA NA NA NA M R P P NA NA NA M R P P NA NA NA M R P P NA NA NA M R P P NA NA P M R P P NA NA P M R P P P P P P R P P P P P P R P P P P P P NA P P P P P P NA P NA P P P NA NA NA NA NA NA NA NA NA NA P P P P NA NA NA NA NA NA NA NA NA NA NA P P P P NA
Hazardous Environments 334 336 461 462 463 464 Ex t, Dust group III B T125C Db (nonconductive dust) acc. IEC/EN60079-31 Ex t, Dust group III C T125 Db (conductive dust) acc. IEC/EN60079-31 Ex d(e) design, Group II C Ex d(e) design, temperature class T5. Ex d(e) design, temperature class T6. Alleinschutz' design. Certification of flame proof motor and protection device together. 507 812 813 Ex d from Ex de Explosion protection according to IECstandards. Thermistor-based surface temperature protection T4 for frequency convertor duty.
1)
R R M R R P
R R M R R P
R R M R R P
R R M R R P
R R M R R P
M M M R R P
M M M R R P
P P M R R P
P P M R R P
P P M R R P
P P P R NA P
P P P R NA R
P P P R NA R
P P P R NA R
NA NA NA NA NA R
NA S M
NA S M
NA S M
NA S M
NA S M
M S M
M S M
NA S M
NA S M
NA S M
NA S M
NA S P
NA S P
NA S P
NA S P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 M NA 100 M NA 112 M NA 132 M NA 160 M P 180 M P 200 M P 225 M P 250 M P 280 M P 315 P P 355 P P 400 P P 450 P P
814 816
Ex tD (DIP) motors, temperature class T 150 C. Pt-100-based surface temperature protection T4 for frequency convertor duty. 3-wire system.
M NA
Heating elements 450 451 Heating element, 100-120V. Heating element, 200-240V. M M M M M M M M M M M M M M M M M M M M M M P P P P P P P P
Insulation system 014 405 Winding insulation class H. Special winding insulation for frequency converter supply. Mounting arrangements 007 008 009 047 066 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001) & IM B34 (2101) 093 228 229 235 236 245 246 255 256 257 258 259 260 305 309 311 IM 3601 flange mounted, IEC flange, from IM 1001 (B14 from B3). Flange FF 130. Flange FT 130. Flange FF 165. Flange FT 165. Flange FF 215. Flange FT 215. Flange FF 265. Flange FT 265. Flange FF 100. Flange FT 100. Flange FF 115. Flange FT 115. Additional lifting lugs. IM 1001 foot mounted, from IM 3001 (B3 from B5). IM 2001 foot/flange mounted, IEC flange, from IM 3001 (B35 from B5). Noise reduction 055 Painting 105 111 Paint thickness report. Painting system C3M acc. to ISO 129445:2007
1)
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
M M M M M
M M M M M
M M M M M
M M M M M
M M M M M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA M NA M
NA NA P NA P
NA NA P NA P
NA NA P NA P
NA NA P NA P
M M M S M NA NA NA NA M M M M NA M M
M M M S M NA NA NA NA M M M M NA M M
M M M M M S M NA NA NA NA NA NA NA M M
M M M M M S M NA NA NA NA NA NA NA M M
M NA NA M M M M S M NA NA NA NA NA M M
NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA M NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
P S
P S
P S
P S
P S
P S
P S
P S
P S
P S
P S
P S
P S
P S
P S
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 M P P P P P 100 M P P P P P 112 M P P P P P 132 M P P P P P 160 M P P P P P 180 M P P P P P 200 M P P P P P 225 M P P P P P 250 M P P P P P 280 M P P P P P 315 P P P P P P 355 P P P P P P 400 P P P P P P 450 P P P P P P
114 115 168 303 710 754 Protection 005 072 073 158 239 240 401 403 404 434 783
Special paint colour, standard grade. Painting system C4M acc. to ISO 129445:2007 Primer paint only. Painted insulation layer on inside of the terminal boxes. Thermally sprayed zink metallizing with acrylic top coat Painting system C5M acc. to ISO 129445:2007
M P P P P P
Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Sealed against oil at D-end. Degree of protection IP65. Opendeck saltwater execution Opendeck fresh water execution Protective roof, horizontal motor. Degree of protection IP 56 Degree of protection IP56, without fan and fan cover. Degree of protection IP 56, open deck. Labyrinth sealing at D-end.
M M P M NA NA P M NA NA P
M M P M NA NA P M NA NA P
M M P M NA NA P M NA NA P
M M P M NA NA P M NA NA P
M M P M NA NA P M NA NA P
M M P M P P P M NA P P
M M P M P P P M NA P P
M M P M P P P M R P P
M M P M P P P M NA P P
M M P M P P P M NA P P
M NA P M P P P M NA P P
P NA P P P P P P NA P P
P NA NA P P P P P NA P S
P NA NA P P P P P NA P S
P NA NA NA NA NA P NA NA NA S
Rating & instruction plates 002 004 095 126 135 139 159 161 163 333 Restamping voltage, frequency and output, continuous duty. Additional text on std rating plate (max 12 digits on free text line). Restamping output (maintained voltage, frequency), intermittent duty. Tag plate Mounting of additional identification plate, stainless. Additional identification plate delivered loose. Additional plate with text "Made in ...." Additional rating plate delivered loose. Frequency converter rating plate. Rating data according to quotation. For Export Only M M M M M M M M M M M P P P P M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M P P M P P P P P P P P M M M M M M M M M M M P P P P P M P M P M P M P M P M P M P M P M P M P M P P P P P P P P M M M M M M M M M M M P P P P P P P P P P P P P P P P P P P M M M M M M M M M M M P P P P
Shaft & rotor 069 070 164 165 410 Two shaft extensions as per basic catalogue. One or two special shaft extensions, standard shaft material. Shaft extension with closed key-way. Shaft extension with open key-way. Stainless steel shaft (standard or nonstandard design).
1)
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P P S P
P P P S P
P P P S P
P P P S P
P P NA S P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
Standards and Regulations 151 421 482 504 Design according to SHELL DEP 33.66.05.31-Gen. June 2007 VIK design (Verband der Industriellen Energie- und Kraftwirtschaft e.V.). Design according to Neste OY & Jacobs, specification N-114 E, rev 5, 1.12.2010 Design according to Neste OY & Jacobs, specification N-114 E, rev 5, 01.12.2010 with SPM adapter 505 VIK design with ABB standard shaft dimensions (Verband der Industriellen Energie- und Kraftwirtschaft e.V.). 540 541 775 778 779 782 788 802 China energy label Inmetro certification Design according to SHELL DEP 33.66.05.31-Gen. January 1999 design. GOST Export/Import Certificate (Russia). SASO Export/Import Certificate (Saudi Arabia) Fulfilling CQST Certification requirements (China) Documentation for Korean KOSHA certification GOST Kazakhstan certified P P NA NA NA P P P P P P P P NA NA M M M M M M M M M M M P P P NA M M M M M M M M M M M P P P P P M P M P M P M P M M M M M P M P M P M M M P P P P P P NA P P M M P M M P M M P M M P M M M P M M P M M P M M P M M P M M P M P P P P P P NA P P NA NA NA P P P P P P P P P P P P P P P P P P P P P P P P P P P P P NA P P P P P P P P P P P P P P NA P P P P P M M M M M P P P P P M M M M M M M M M M P P P P NA
Stator winding temperature sensors 120 121 122 123 125 127 KTY 84-130 (1 per phase) in stator winding. Bimetal detectors, break type (NCC), (3 in series), 130 C, in stator winding. Bimetal detectors, break type (NCC), (3 in series), 150 C, in stator winding. Bimetal detectors, break type (NCC), (3 in series), 170 C, in stator winding. Bimetal detectors, break type (NCC), (2x3 in series), 150 C, in stator winding. Bimetal detectors, break type (NCC), (3 in series, 130 C & 3 in series, 150 C), in stator winding. 328 435 436 439 441 445 PTC - thermistors (3 in series), 120 C, in stator winding PTC - thermistors (3 in series), 130 C, in stator winding. PTC - thermistors (3 in series), 150 C, in stator winding. PTC - thermistors (2x3 in series), 150 C, in stator winding. PTC - thermistors (3 in series, 130 C & 3 in series, 150 C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase
1)
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P P P P
P P P P P P
P P P P P P
P P P P P P
P P P P P P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
M M S M M P
P P S P P P
P P S P P P
P P S P P P
P P S P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 NA NA NA P 100 NA NA NA P 112 NA NA NA P 132 NA NA NA P 160 P P P P 180 P P P P 200 P P P P 225 P P P P 250 P P P P 280 P P P P 315 P P P P 355 P P P P 400 P P P P 450 P P P P
Pt-100 2-wire in stator winding, 2 per phase Pt-100 3-wire in stator winding, 1 per phase. Pt-100 3-wire in stator winding, 2 per phase. PTC thermistors (2 x 3 in series), 130 C, in stator winding
NA NA NA P
Terminal box 021 022 157 180 277 278 279 292 293 294 295 300 380 400 402 413 418 466 468 469 567 568 728 729 730 732 733 734 735 Terminal box LHS (seen from D-end). Cable entry LHS (seen from D-end). Terminal box degree of protection IP 65. Terminal box RHS (seen from D-end). Cable sealing end unit, size small for C-opening Cable sealing end unit, size medium for D-opening Cable sealing end unit, size large for D-opening Adapter C-C Adapter D-D Adapter E-D Adapter E-2D Increased single core cross section Separate terminal box for temperature detectors, std. material 4 x 90 turnable terminal box. Terminal box adapted for Al cables. Extended cable connection, no terminal box. Separate terminal box for auxiliaries, standard material. Terminal box at N-end. Cable entry from D-end. Cable entry from N-end. Separate terminal box material: Cast Iron Separate terminal box for heating elements, std. material Standard cable gland, Ex d IIB, armoured cable, double sealing. Aluminum non-drilled flange for cable glands Prepared for NPT cable glands Standard cable gland, Ex d IIB, armoured cable. Standard cable gland, Ex d IIB, nonarmoured cable. Standard cable gland, Ex d IIC, armoured cable. Standard cable gland, Ex d IIC, nonarmoured cable.
1)
NA M M NA NA NA NA NA NA NA NA P NA S NA NA NA NA M M NA NA P P P M M M M
NA M M NA NA NA NA NA NA NA NA P NA S NA NA NA NA M M NA NA P P P M M M M
NA M M NA NA NA NA NA NA NA NA P NA S NA NA NA NA M M NA NA P P P M M M M
NA M M NA NA NA NA NA NA NA NA P NA S NA NA NA NA M M NA NA P P P M M M M
NA M M NA NA NA NA NA NA NA NA P NA S NA NA NA NA M M NA NA P P P M M M M
P M M P NA NA NA NA NA NA NA P P S NA P P NA M M S P P P P M M M M
P M M P NA NA NA NA NA NA NA P P S NA P P NA M M S P P P P M M M M
NA M M NA NA NA NA NA NA NA NA P P S NA P P P M M P P P P P M M M M
NA M M NA NA NA NA NA NA NA NA P P S NA P P P M M P P P P P M M M M
NA M M NA NA NA NA NA NA NA NA P P S NA P P P M M P P P P P M M M M
NA M M NA P NA NA P NA NA NA P P S S P P P M M P P P P P M M M M
NA P P NA NA P P NA P P P P P S S P P P P P P P P P P P P P P
NA P P NA NA P P NA P P P P P NA S P P P R R P P P P P P P P P
NA P P NA NA P P NA NA P P P P NA S P P P R R P P P P P P P P P
NA P NA NA NA P P NA NA P P P P NA S P P P NA NA P P P P P P P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
Code 1)
Variant
Frame size 80 90 S P M M M P 100 S P M M M P 112 S P M M M P 132 S P M M M P 160 S P M M M P 180 S P M M M P 200 S P M M M P 225 S P M M M P 250 S P M M M P 280 S P M M M P 315 S P P P P P 355 S P P P P P 400 S P P P P P 450 S P P P P P
736 737 743 744 745 746 Testing 145 146 148 149 150 222
Standard cable gland Ex e acc. to ENstandards. Standard cable gland Ex e with clamping device acc. to EN-standards. Painted non-drilled flange in steel for cable glands Stainless steel non-drilled flange for cable glands. Painted steel flange equipped with nickle plated brass cable glands Stainless steel cable flange equipped with standard nickle plated brass cable glands
S P M M M P
Type test report from a catalogue motor, 400V 50Hz. Type test with report for one motor from specific delivery batch. Routine test report. Test according to separate test specification. Customer witnessed testing. Specify test procedure with other codes. Torque/speed curve, type test and multipoint load test with report for one motor from specific delivery batch.
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
P P P R P P
P P P R P P
P P P R P P
P P P R P P
Nuclear motor testing Vibration level test Vibration spectrum test for one motor from specific delivery batch. Noise level test for one motor from specific delivery batch. Noise spectrum test for one motor from specific delivery batch. Test for one motor from specific delivery batch with ABB frequency converter available at ABB test field. ABB standard test procedure.
P M P P R P
P M P P R P
P M P P R P
P M P P R P
P M P P R P
NA M P P P P
NA M P P P P
NA M P P P P
NA M P P P P
NA M P P P P
NA M P P P P
NA P P P P P
NA P P P P P
NA P P P P P
NA P P P P P
Variable speed drives 181 Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. 479 680 701 704 747 Mounting of other type of pulse tacho with shaft extension, tacho not included. 2048 pulse tacho, Ex d, tD, L&L 841910001 Insulated bearing at N-end. EMC cable gland. 1024 pulse tacho, Ex d, tD, L&L 841910002
1)
NA NA NA M NA
NA NA NA M NA
NA NA NA M NA
NA NA NA M NA
NA NA NA M NA
P P NA M P
P P NA M P
P P NA M P
P P NA M P
P P NA M P
P P M M P
P P P P P
P P P P P
P P P P P
P P P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
HD
M000267 M000268 M000270
PN
H K A
B B
M S
M000269
M000271
M000272
45
GA
45
Sizes 80 to 200 Sizes 225 to 450 Protective roof, variant code 005
Motor size
80 90 100 112 132 160 180 200 225 250 280 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450
IM 1001, IM B3 AND IM 3001, IM B5 D GA F E poles poles poles poles 2 4-8 2 4-8 2 4-8 2 4-8 19 19 21.5 21.5 6 6 40 40 24 24 27 27 8 8 50 50 28 28 31 31 8 8 60 60 28 28 31 31 8 8 60 60 38 38 41 41 10 10 80 80 42 42 45 45 12 12 110 110 48 48 51.5 51.5 14 14 110 110 55 55 59 59 16 16 110 110 55 60 59 64 16 18 110 140 60 65 64 69 18 18 140 140 65 75 69 79.5 18 20 140 140 65 80 69 85 18 22 140 170 65 90 69 95 18 25 140 170 70 100 62.5 90 20 28 140 210 70 100 62.5 90 20 28 140 210 70 100 62.5 90 20 28 140 210 80 110 85 126 22 28 170 210 80 100 85 106 22 28 170 210 80 120 127 32 210
L max poles 2 340 405 480 480 560 808 826 774 841 875 1090 1176 1285 1409 1514 1764 1851 1851 -
O 4-8 340 405 480 480 560 808 826 774 871 875 1090 1206 1315 1479 1584 1834 1891 1891 2071
IM 1001, IM B3 A B B C
HD
IM 3001, IM B5 M N P S
125 140 160 190 216 254 279 318 356 406 457 508 508 610 610 610 710 686 800
100 100 140 140 140 210 241 267 286 311 368 406 457 500 560 710 900 710 1000
125 125 178 254 279 305 311 349 419 457 508 560 630 900 1000 800 1120
50 56 63 70 89 108 121 133 149 168 190 216 216 254 254 254 224 280 250
235 260 280 295 340 499 539 573 620 683 768 858 858 984 984 984 1071 1071 1255
80 90 100 112 132 160 180 200 225 250 280 315 315 355 355 355 400 400 450
165 165 215 215 265 300 300 350 400 500 500 600 600 740 740 740 940 740 1080
130 130 180 180 230 250 250 300 350 450 450 550 550 680 680 680 880 680 1000
200 200 250 250 300 350 350 400 450 550 550 660 660 800 800 800 1000 800 1150
Tolerances: A, B D, DA F, FA H N C, CA 0,8 ISO k6 < 50mm ISO m6 > 50mm ISO h9 -0.5 ISO j6 0.8
Above table gives the main dimensions in mm. For detailed drawings please see our web-pages www.abb.com/motors&generators or contact ABB.
S = Standard ange
M = Modication
NA = Not applicable
M000231
Protective roof DS LS poles 2 4-8 160 360 360 180 430 430 195 505 505 195 505 505 260 590 590 328 756 756 359 756 756 414 844 844 462 921 951 506 965 965 555 1192 1192 624 1293 1323 624 1404 1434 720 1526 1596 720 1633 1703 720 1881 1951 810 1860 1900 810 1860 1900 On request
M000230
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Stator frame Endshield, D-end Screws for endshield, D-end Endshield, N-end Screws for endshield, N-end Rotor with shaft Key, D-end Terminal box Terminal board Intermediate flange Screws for terminal box cover Outer bearing cover, D-end Valve disc with labyrinth seal, D-end; standard in 2-pole motors (V-ring in 4-8 pole) Bearing, D-end Inner bearing cover, D-end Screws for bearing cover, D-end
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Outer bearing cover, N-end Seal, N-end Wave spring (280-315) Coil spring (355-450) Valve disc, N-end Bearing, N-end Inner bearing cover, N-end Screws for bearing cover, N-end Fan Fan cover Screws for fan cover Rating plate Regreasing plate Grease nipple, D-end Grease nipple, N-end SPM nipple, D-end SPM nipple, N-end
M000220
Certicate examples
M000726a
M000725-1
M000725-2
M000727a
Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Forged steel, detachable feet Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6205-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3 6208-2Z/C3 6309/C3 6309/C3 6310/C3 6310/C3
Axially-locked bearings Inner bearing cover Bearing seal Lubrication SPM-nipples Rating plate Terminal box Material Frame material Cover material Cover screws material Connections Cable entries Terminals Fan Material
As standard, locked at D-end Gamma-ring Permanent grease lubrication Stainless steel Cast iron, EN-GJL-200 or better Cast iron, EN-GJL-200 or better Acidproof steel A4-80 Steel 8.8, zinc electroplated and chromated. 1 x M25 x 1.5 2 x M32 x 1.5 2 x M40 x 1.5 Regreasable bearings As standard
6 terminals for connection with cable lugs (not included) Polyamide. Reinforced with glass bre. Polypropylene. Reinforced with glass bre.
Fan cover
Steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors as standard Pressure die-cast aluminum Half key balancing Closed key-way As standard IP 55 IC 411
Stator winding
Rotor winding Balancing Key way Drain holes External earthing bolt Enclosure Cooling method
Material
Optional
Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Cast iron, EN-GJL-200 or better, integrated with stator Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6312M/C3 6312/C3 6310M/C3 6310/C3 6313M/C3 6313/C3 6312M/C3 6312/C3 6315M/C3 6315/C3 6313M/C3 6313/C3 6316/C3 6316/C3 6316/C3 6319/C3 6316M/C3 6322/C3 6316M/C3 6317M/C3 6324/C3 6317M/C3 6319/C3 6326M/C3 6322/C3
6 terminals for connection with cable lugs (not included) Polypropylene. Reinforced with glass bre. Polypropylene reinforced with glass bre or aluminum.
Fan cover
Hot dip galvanized steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors as standard Pressure die-cast aluminum Half key balancing Close Open
Stator winding
Material
Heating elements Drain holes External earthing bolt Enclosure Cooling method
On request
60 W
120 W
200W
Increased safety motors, Ex e II T3 Gb Totally enclosed squirrel cage three phase low voltage motors, Sizes 80 to 400, 0.55 to 390 kW
www.abb.com/motors&generators > Motors for explosive atmospheres >> Increased safety motors
Mechanical design
Drain holes
Increased safety Ex e motors in frame sizes 200 to 400 are fitted with drain holes and plugs as standard. Plugs are of plastic material and are delivered in open position. Drain holes and plugs are available for frame sizes 80 to 180 as an option. Please see variant code section.
Closed
Open
Bearing seals
The following bearing seals are used as standard, special seals like radial seal are available as option. Please see variant code section.
M000178
Open
Standard delivery 400/690 V (if nothing else informed) Cable entries for supply cables
Motor size Pole number Terminal box type Terminal box opening 80-90 100-132 160-180 200-250 280 315SM, ML 355 SMA, SMB, SMC 355 SMC 355 SMC 355 SMA, SMB 355 ML, LK 355 ML, LK 400 L, LK 400 L, LK 2-8 2-8 2-8 2-8 2-8 2-8 2-4 6 8 6-8 2-4 6-8 2-6 8 25 25 63 160 210 370 750 750 370 370 750 750 750 750 B B B B C D E E D D E E E E E-D E-D E-D E-D E-D E-D 1xM25 2xM32 2xM40 2xM50 2xM63 2xM63 2xM63 2xM63 1xM25 2xM32 2xM40 2xM50 2xM63 2xM63 2xM63 2xM63 medium medium large medium large medium 45 adapter Threaded holes Cable gland Cable sealing end unit Cable outer Single core diameter mm 1x10-16 2x16-21 2x18-27 2x26-35 2x32-49 2x32-49 2x48-60 2x48-60 2x32-49 2x32-49 2x60-80 2x48-60 2x60-80 2x48-60 mm2 for rated power 10 10 35 70 2x150 2x240 4x240 4x240 2x240 2x240 4x240 4x240 4x240 4x240 M5 M5 M6 M10 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 Terminal bolt cross-section size 6 x
Earthings on motor
80-132 160-180 200-250 280-315 355-400 Frame M6 M6 M8 M10 M10 Terminal box M6 M6 M8 2xM10 2xM10 Terminal box type 25 63 160 210, 370 750
Adapters
How to order? Check first that the terminal box can allow mounting of the cable and cores (refer to motor type and terminal box type cross reference page 85). If very large cables are used might it be neccesary to use a larger terminal box than standard. Select the right cable gland(s) or cable sealing end unit(s) depending on outer diamater of the cable(s). Select a appropriate adapter and gland(s) and gland plate or cable sealing end unit. Note that turning the terminal box to a non standard position might limit the use of some adapters.
Ordering example Motor Cables 145 kW, 4 pole, 400 V 50 Hz, cables needed: 2 pieces, outer diameter 58 mm, single cross section 185 mm, cables coming from below
Needed one terminal box for anticondensation heaters (220 V) and another for temperature detectors, terminal box material cast iron. Motor Adapter Cable sealing end unit Auxiliaries M3HP 315 MLA 4, B3 D-D (variant code 293) Variant code 278 Variant codes 451, 380, 567, 568
1. Main terminal box and maximum single core cross section Larger than standard single core cross section is available as option according to the table below. Also one size larger terminal box can be selected. Please check also the capacity of the cable entry to make sure the cables fit.
Standard terminal box Terminal box type 25 63 160 210 370 750 Size of opening B B C C D E Max single core cross section per phase mm2 35 95 120 2 x 240 2 x 300 4 x 500 370 750 1200 D E E Variant code 019 larger terminal box than standard Terminal box type Size of opening Max single core cross section per phase mm2 2 x 240 2 x 300 4 x 500
The accessories for using the maximum single core cross sections are not included as standard. For this option please use variant code 300 (Increased single core cross section). Each terminal box has got limited maximum cable entry size, please request if necessary.
M000443
2. Optional adapters To allow easy termination of cables entering the terminal box from above or below is it recommended to use an angle adapter.
These can also be used to allow mounting of several cable sealing end units or gland plates on the terminal box for termination of more cables than one cable sealing end unit or gland plate can allow.
Gland plate or opening for cable sealing end unit Material Notes
Adapter
Variant code
292
M000430
Steel
293
M000431
Steel
294
M000432
Steel
295
M000433
2 pcs D
Steel
296
M000434
3 pcs D
Steel
444
M000435
2 pcs E
Steel
3. Gland plate, maxium size of glands and material Gland plates are delivered blind or be drilled and tapped to accomodate glands to suit the cable diameter and amount of glands needed. Standard gland plate material is siluminium, painted steel or stainless steel are available as options.
Size B C D E Maximum size and number of glands, metric 2xM40 2xM90 4xM90 6xM90 3xM32 3xM50 4xM63 7xM63 4xM20 7xM32 7xM50 9xM50
variant codes: Cable flanges without holes / Blank gland plates. Prepared for NPT glands Standard cable gland, Ex d IIB, armoured cable. Standard cable gland, Ex d IIB, non-armoured cable. Painted non-drilled flange in steel for cable glands. Stainless steel non-drilled flange for gable glands. Painted steel cable flange equipped with nickle plated brass cable glands. Stainless steel cable flange equipped with nickle plated brass cable glands.
4. Cable glands and cable sealing end units Cable glands Table below shows the selection of cable gland types and possible cable outer diameter of each size.
Outer diameter, mm Variant code 745 Painted steel ange equipped with brass cable glands Motor sizes 80-400: M20 M25 M32 M40 M50 M63 M75 M90
Variant code 737 Standard cable gland Ex e with clamping device acc. to EN-Standards
Cable sealing end unit As an alternative to flanges and cable glands, cable sealing units can be used. These allow more space for spreading the cores for easy terminating on the terminals. Cable sealing end units have rubber sealed entries for one or two main cables. In addition are there two plugged M20 holes for auxillary cables.
Accessories Variant code Opening towards terminal box Cable outer diameter mm Cable entry auxiliary cable Variant code 704; EMC cable gland Variant code 231; with clamping device
277
M000436
1 or 2 pcs 48-60 mm *)
Optional
Optional
278
M000437
1 or 2 pcs 48-60 mm *)
Optional
Optional
279
M000438
1 or 2 pcs 60-80 mm *)
Optional
Optional
*) Depending on how the cable seal inside the cable sealing end unit is used also 40-52 mm is available.
M000437
5. Auxiliary terminal box It's possible to equip the motors from frame size 160 upwards with one or several auxiliary terminal boxes for connection of auxiliaries like heaters or temperature detectors. The standard auxiliary terminal box is made of aluminium and equipped with M20 glands for entry of the connection cables. As an option cast iron terminal box is available. In motor sizes 160 to 180 the material of auxiliary terminal box is cast iron. Connection terminals are spring loaded type for quick and easy connection. These are suitable for up to 2.5 mm2 wires. Auxiliary terminal boxes are equipped with an earthing terminal. As standard the first auxiliary terminal box is located on RHS seen from D-end. Small, aluminum auxiliary terminal box (80 x 125 mm, for max 12 wires) Earthing size M4
Related variant codes: 418 Separate terminal box for auxiliaries, standard material (all connections of temperature detectors and heaters will be put in same box) 380 Separate terminal box for temperature detectors, standard material 568 Separate terminal box for heating elements, standard material 569 Separate terminal box for brakes, standard material 567 Separate terminal box material: Cast iron
Large, aluminum auxiliary terminal box (80 x 250 mm, for max 30 wires) Earthing M4
Cast iron auxiliary terminal box (211 x 188 mm, for max 30 wires) Earthing M6
M000439
M000440
Standard cable entry size M20. Number of entries depends on the terminal box type and number of selected auxiliaries.
M000441
M000365
M000368
Motor sizes 280 to 315 Top- and side-mounted Terminal boxes 210,370
M000368
M000205
M000206
Ex e - M3HP
Motor size 80-132 160-180 200-250 280-400 Terminal box A1
25
63 160 210 370 750 top-mounted 750 side-mounted
202
234 352 416 451 686 525
M000205
M000369
If the radial force is applied between points X0 and Xmax, the permissible force FR can be calculated from the following formula:
Cast iron motors Permissible radial forces according to L10 principle Increased safety motors Ex e II T4 Gb, motor sizes 80 to 132
Motor size 80 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 Poles Length of shaft extention E (mm) 40 40 40 40 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80 80 Ball bearings 40,000 hours FX0 (N) FXmax (N) 619 780 893 983 561 803 919 1011 553 1050 1267 1395 553 1050 1267 1394 1354 1772 2028 2234 524 663 759 834 473 677 775 853 457 868 1047 1153 457 868 1047 1152 1112 1454 1665 1833
90
100
112
132
Cast iron motors Permissible radial forces according to L10 principle Increased safety motors Ex e II T4 Gb, motor sizes 160 to 400
Motor size Poles Lengt of.shaft extension E (mm) 110 110 110 110 110 110 110 110 110 110 110 110 110 140 140 140 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 170 170 170 140 210 210 210 140 210 210 210 140 210 210 210 170 210 210 210 170 210 210 210 Ball bearings 40,000 hours FX0 [N] 2530 3180 3650 4020 2900 3660 4190 4620 3830 4830 5520 6080 4350 5490 6280 6920 4390 6790 7760 8550 5840 7260 8300 9150 5810 9030 10310 11360 5850 9000 10270 11330 5880 9090 10270 11360 5790 11930 13630 15050 5770 11980 13650 15090 5670 12020 13680 15160 4450 12120 13750 15280 4450 12120 13750 15280 FXmax [N] 2120 2670 3060 3370 2440 3080 3520 3880 3160 3980 4550 5010 3660 4420 5060 5570 4350 5480 6270 6900 4900 6110 6980 7700 4960 7470 8530 9400 5080 7620 8700 9590 5210 7870 8890 9840 5090 9890 11300 12470 5120 10090 11500 12710 5140 10420 11860 13150 3970 10550 11970 13310 3970 10550 11970 13310 Roller bearings 40,000 hours FX0 [N] 6400 7880 8900 9700 6970 8580 9700 10570 9500 11710 13230 14420 11650 14340 16190 17660 15420 18980 21440 23370 16500 20100 22690 24740 16540 26590 30030 32740 16710 26580 30010 32720 16900 26950 30390 33150 16790 36660 41390 45140 16880 36960 41720 45503 17030 37470 42290 46130 19390 43040 48570 52990 19390 43040 48570 52990 FXmax [N] 3160 3130 3140 3150 4380 4360 4360 4370 7100 7090 7080 7090 7090 7340 7330 7330 7360 9320 9330 9320 6350 9690 9680 9690 6280 10170 10160 10100 6200 14570 14580 14510 6080 14410 14210 14130 7470 14590 14530 14460 7110 14290 14210 14110 6570 13850 13660 13510 8760 18600 17980 18180 8760 18600 17980 18180
160 ML_
180 ML_
200 ML_
225 SM_
250 SM_
280 SM_
315 SM_
315 ML_
315 LK_
355 SM_
355 ML_
355 LK_
400 L_
400 LK_
2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
FAD
Cast iron motors, sizes 80 to 400 Mounting arrangement IM B3
Motor size 40,000 hours 2-pole FAD N 660 740 1100 1100 1530 2050 2570 3300 3710 5200 4870 4780 4730 1660 1570 1440 810 810 4-pole FAD N 820 900 1320 1320 1870 2620 3230 4180 4690 6400 6140 7170 7080 5760 5640 5460 4250 4250
FAZ
80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_
FAZ N 300 220 220 220 500 1440 1470 2040 2240 2100 2870 2780 2730 5460 5370 5240 5810 5810
FAZ N 460 380 430 430 840 2010 2130 2920 3230 3310 4140 5170 5080 9560 9440 9260 10250 10250
6-pole FAD N 940 1010 1480 1480 2110 3060 3730 4820 5410 7260 7040 8210 8100 7060 6880 6680 5510 5410
M000022
FAZ N 580 490 590 590 1080 2440 2630 3560 3940 4160 5040 6210 6100 10860 10680 10480 11510 11410
8-pole FAD N 1030 1110 1610 1610 2320 3410 4140 5360 6010 8000 7840 9180 9060 8290 8100 7810 6630 6630
FAZ N 670 590 720 720 1280 2790 3040 4100 4540 4900 5840 7180 7070 12090 11900 11610 12630 12630
FAZ
M000023
FAD
Mounting arrangement IM V1
Motor size 40,000 hours 2-pole FAD N 690 780 1180 1180 1700 2440 3120 3960 4570 6240 6440 6950 7280 5330 5860 6600 8010 8010 4-pole FAD N 860 950 1430 1430 2080 3160 3980 5030 5770 7720 8170 9820 10300 11110 11810 12850 13680 13680 6-pole FAD N 970 1080 1600 1600 2380 3590 4490 5820 6660 8930 9580 11760 12330 13720 14718 15800 16610 17180 8-pole FAD N 1070 1170 1730 1730 2580 3950 4890 6370 7280 9690 10380 12740 13310 14980 15970 17500 18480 18480
80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_
1)
FAZ N 280 190 170 170 390 1180 1100 1590 1650 1380 1780 1270 940 2890 2360 1630 730 730
FAZ N 440 340 360 360 690 1650 1630 2340 2500 2410 2760 3350 2870 5820 5130 4080 3650 3650
FAZ N 550 450 510 510 900 2090 2130 2890 3100 3047 3340 3810 3240 6270 5280 4190 3840 3270
FAZ N 650 540 640 640 1110 2430 2550 3430 3700 3780 4150 4780 4210 7530 6540 5000 4530 4530
On request
Rating plates
The rating plates are in table form giving values for speed, current and power factor for one voltage: 400 V as standard. Other voltage and frequency combinations are possible and can be ordered with variant codes 002 or 209. Please see Variant code section. The following information will be shown on the motor rating plate:
Lowest nominal efficiency at 100 %, 75 % and 50 % rated load Efficiency level Year of manufacture Type of protection Apparatus group Temperature class Identification number of the certification body Certificate number: ATEX I A/IN tE
M000738
Position 13 Voltage and frequency Single-speed motors B 380 V 50 Hz D 400 V, 415 V, 690 VY 50 Hz E 500 V 50 Hz F 500 VY 50 Hz S 230 V, 400 VY, 415 VY 50 Hz T 660 V 50 Hz U 690 V 50 Hz X Other rated voltage, connection or frequency, 690 V maximum
Position 11 - (dash)
Position 14
Generation code G, H... The product code must be, if needed, followed by variant codes.
IE2
Output kW Motor type Product code 3000 r/min = 2 poles 400 V 50 Hz 0.75 M3HP 80 MA 3GHP 081 310-H 1.1 M3HP 80 MB 3GHP 081 320-H 1.5 M3HP 90 SLA 3GHP 091 010-H 2.2 M3HP 90 SLC 3GHP 091 030-H 3 M3HP 100 LA 3GHP 101 510-H 3.7 M3HP 112 MB 3GHP 111 320-H 5.5 M3HP 132 SMB 3GHP 131 220-H 7.5 M3HP 132 SMD 3GHP 131 240-H 8 M3HP 160 MLB 3GHP 161 420-H 11 M3HP 160 MLC 3GHP 161 430-H 12.5 M3HP 160 MLD 3GHP 161 440-H 15 M3HP 180 MLB 3GHP 181 420-H 18 M3HP 180 MLC 3GHP 181 430-H 22 M3HP 200 MLC 3GHP 201 430-G 25 M3HP 200 MLE 3GHP 201 450-G 30 M3HP 225 SMB 3GHP 221 220-G 36 M3HP 225 SMD 3GHP 221 240-G 40 M3HP 250 SMB 3GHP 251 220-G 47 M3HP 250 SMC 3GHP 251 230-G 1) M3HP 280 SMA 3GHP 281 210-G 60 1) M3HP 280 SMB 3GHP 281 220-G 75 1) M3HP 315 SMA 3GHP 311 210-G 77 1) 80 M3HP 280 SMC 3GHP 281 230-G 1) M3HP 315 SMB 3GHP 311 220-G 90 120 1) M3HP 315 SMC 3GHP 311 230-G 135 1) M3HP 315 MLA 3GHP 311 410-G 175 1) M3HP 355 SMA 3GHP 351 210-G 200 1) M3HP 355 SMB 3GHP 351 220-G 220 1) M3HP 355 MLA 3GHP 351 410-G 300 1) M3HP 355 LKA 3GHP 351 810-G 355 2) M3HP 400 LB 3GHP 401 520-G 355 2) M3HP 400 LKB 3GHP 401 820-G 400 2) M3HP 400 LC 3GHP 401 530-G 400 2) M3HP 400 LKC 3GHP 401 830-G
1)
Power IN Is Tl TN factor cos A IN Nm TN CENELEC-design 0.87 1.55 7.3 2.5 3.7 0.87 2.2 5.9 3.7 3.0 0.88 3 6.7 4.9 3.0 0.89 4.2 7.8 7.3 2.7 0.90 5.5 6.8 9.8 2.2 0.89 6.9 7.8 12.1 3.9 0.90 10.1 6.9 18 2.4 0.90 13.6 7.6 24.5 2.8 0.91 14 7.2 25.9 2.8 0.92 19.5 6.9 35.8 2.6 0.91 21 7.6 40.5 2.8 0.91 26 7.1 48.6 2.2 0.91 31 7.6 58 2.4 0.90 38.5 6.9 71 2.6 0.90 44 7.0 80.7 2.9 0.91 51 7.4 96.6 2.1 0.92 60 8.0 115 2.3 0.91 67 7.8 128 2.2 0.91 80 7.8 151 2.3 0.91 100 7.3 192 1.2 0.91 125 7.6 240 1.2 0.90 132 7.3 246 0.9 0.92 132 7.4 256 1.2 0.90 152 7.2 288 0.9 0.91 201 7.4 384 1.0 0.92 222 8.0 432 1.2 0.91 290 7.4 559 0.8 0.91 333 7.3 639 0.8 0.91 363 7.1 704 0.9 0.92 488 7.4 959 0.9 0.91 580 7.6 1134 0.7 0.91 580 7.6 1134 0.7 0.92 645 7.5 1278 0.8 0.92 645 7.5 1278 0.8
Moment Sound pressure Time of inertia 2 tE 50 J = 1/4 GD Weight level LPA Hz kgm2 kg dB 15 11 12 6 7 5 9 5 15 9 8 15 11 10 9 10 7 8 6 10 8 13 7 10 6 6 10 7 8 6 7 7 6 6 0.0006 0.0007 0.001 0.0014 0.0036 0.0043 0.009 0.012 0.052 0.062 0.07 0.13 0.13 0.21 0.22 0.31 0.36 0.66 0.69 0.8 0.9 1.2 1.15 1.4 1.7 2.1 3 3.4 4.1 4.8 8.2 8.2 9.3 9.3
Is / IN
28 30 41 44 61 64 92 100 216 227 233 292 292 305 310 365 395 475 495 625 665 880 725 940 1025 1190 1600 1680 2000 2320 3050 3050 3300 3300
59 59 61 61 65 65 71 71 69 69 69 69 69 72 72 74 74 74 74 77 77 78 77 78 78 78 83 83 83 83 82 82 82 82
3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
2)
Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045 Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
IE2
Output kW Motor type Product code 1500 r/min = 4 poles 400 V 50 Hz 0.55 M3HP 80 MA 3GHP 082 310-H 0.75 M3HP 80 MB 3GHP 082 320-H 1.1 M3HP 90 SLA 3GHP 092 010-H 1.5 M3HP 90 SLC 3GHP 092 030-H 2.2 M3HP 100 LA 3GHP 102 510-H 3 M3HP 100 LB 3GHP 102 520-H 3.7 M3HP 112 MC 3GHP 112 330-H 5.5 M3HP 132 SMB 3GHP 132 220-H 7.5 M3HP 132 SMD 3GHP 132 240-H 11 M3HP 160 MLC 3GHP 162 430-H 15 M3HP 160 MLE 3GHP 162 450-H 17 M3HP 180 MLB 3GHP 182 420-H 20 M3HP 180 MLC 3GHP 182 430-H 26 M3HP 200 MLA 3GHP 202 410-G 30 M3HP 200 MLB 3GHP 202 420-G 38 M3HP 225 SMB 3GHP 222 220-G 43 M3HP 225 SMC 3GHP 222 230-G 50 M3HP 250 SMA 3GHP 252 210-G 60 M3HP 250 SMB 3GHP 252 220-G 65 M3HP 280 SMA 3GHP 282 210-G 75 M3HP 280 SMB 3GHP 282 220-G 82 M3HP 280 SMC 3GHP 282 230-G 95 M3HP 315 SMA 3GHP 312 210-G 110 M3HP 315 SMB 3GHP 312 220-G 128 M3HP 315 SMC 3GHP 312 230-G 145 M3HP 315 MLA 3GHP 312 410-G 190 M3HP 355 SMA 3GHP 352 210-G 230 M3HP 355 SMB 3GHP 352 220-G 280 M3HP 355 MLA 3GHP 352 410-G 310 M3HP 355 LKA 3GHP 352 810-G 350 M3HP 400 LA 3GHP 402 510-G 350 M3HP 400 LKA 3GHP 402 810-G 390 M3HP 400 LC 3GHP 402 530-G 390 M3HP 400 LKC 3GHP 402 830-G
Power IN Is Tl TN factor cos A IN Nm TN CENELEC-design 0.73 1.41 4.9 3.6 2.3 0.76 1.77 5.2 5 2.2 0.77 2.4 5.9 7.3 2.8 0.79 3.2 6.5 10 2.3 0.86 4.3 7.0 14.5 2.7 0.83 6 7.3 19.8 2.7 0.78 7.7 8.7 24.2 3.0 0.80 11 7.9 36 3.0 0.75 16.1 6.8 49 3.3 0.85 21 6.7 71.9 2.6 0.84 29 8.0 97.5 3.1 0.85 33 6.2 110 2.3 0.85 38 7.6 129 2.7 0.88 47 7.9 167 1.9 0.89 54 7.4 193 1.9 0.89 67 7.7 245 1.7 0.90 76 7.7 277 1.8 0.88 88 7.1 322 1.5 0.89 105 7.3 386 1.7 0.88 113 7.4 417 1.5 0.89 130 7.2 482 1.5 0.90 139 7.0 528 1.5 0.88 165 6.9 609 1.1 0.88 188 6.8 705 1.1 0.89 217 6.8 822 1.1 0.89 245 6.9 931 1.1 0.87 330 7.1 1216 1.0 0.87 393 7.3 1472 1.1 0.88 475 7.0 1793 1.1 0.88 525 6.9 1986 1.1 0.89 590 6.4 2241 1.2 0.89 590 6.4 2241 1.2 0.88 660 7.4 2494 1.0 0.88 660 7.4 2494 1.0
Moment Sound pressure Time of inertia 2 tE 50 J = 1/4 GD Weight level LPA Hz kgm2 kg dB 20 20 20 0 20 12 0 14 0 12 9 7 11 13 9 9 5 8 8 8 6 6 8 8 5 5 9 6 5 7 6 6 6 6 0.001 0.0012 0.002 0.003 0.0075 0.0081 0.013 0.023 0.034 0.096 0.13 0.21 0.248 0.3 0.35 0.45 0.53 0.77 0.98 1.25 1.5 1.85 2.3 2.6 2.9 3.5 5.9 6.9 8.4 10 15 15 17 17
Is / IN
29 29 42 44 61 63 72 102 105 226 249 279 298 280 305 365 390 425 470 625 665 725 900 960 1000 1160 1610 1780 2140 2500 3200 3200 3400 3400
59 59 54 54 52 52 52 60 60 62 68 66 66 73 73 74 74 73 73 68 68 68 73 73 73 73 75 78 78 78 78 78 78 78
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
IE2
Output kW Motor type Product code 1000 r/min = 6 poles 400 V 50 Hz 0.37 M3HP 80 MA 3GHP 083 310-H 0.55 M3HP 80 MB 3GHP 083 320-H 0.75 M3HP 90 SLA 3GHP 093 010-H 1.1 M3HP 90 SLC 3GHP 093 030-H 1.5 M3HP 100 LA 3GHP 103 510-H 2.2 M3HP 112 MB 3GHP 113 320-H 3 M3HP 132 SMB 3GHP 133 220-H 4 M3HP 132 SMC 3GHP 133 230-H 5.5 M3HP 132 SMD 3GHP 133 240-H 6.6 M3HP 160 MLA 3GHP 163 410-H 7.5 M3HP 160 MLB 3GHP 163 420-H 1) M3HP 160 MLC 3GHP 163 430-H 11 1) 14 M3HP 180 MLB 3GHP 183 420-H 16.5 M3HP 200 MLB 3GHP 203 420-G 20 M3HP 200 MLC 3GHP 203 430-G 30 M3HP 225 SMC 3GHP 223 230-G 37 M3HP 250 SMB 3GHP 253 220-G 45 M3HP 280 SMA 3GHP 283 210-G 50 M3HP 280 SMB 3GHP 283 220-G 62 M3HP 280 SMC 3GHP 283 230-G 72 M3HP 315 SMA 3GHP 313 210-G 85 M3HP 315 SMB 3GHP 313 220-G 100 M3HP 315 SMC 3GHP 313 230-G 120 M3HP 315 MLA 3GHP 313 410-G 150 M3HP 355 SMA 3GHP 353 210-G 180 M3HP 355 SMB 3GHP 353 220-G 230 M3HP 355 MLB 3GHP 353 420-G 260 M3HP 355 LKA 3GHP 353 810-G 300 M3HP 400 LA 3GHP 403 510-G 300 M3HP 400 LKA 3GHP 403 810-G 350 M3HP 400 LB 3GHP 403 520-G 350 M3HP 400 LKB 3GHP 403 820-G
1)
Power IN Is Tl TN factor cos A IN Nm TN CENELEC-design 0.64 1.14 4.8 3.7 3.4 0.70 1.55 4.3 5.5 2.8 0.69 2 4.9 7.5 2.1 0.71 2.8 4.7 11.2 1.8 0.74 3.6 4.2 15 2.3 0.76 5 5.9 22.1 2.2 0.77 6.7 6.1 29.8 2.1 0.74 9.2 6.6 39.6 2.3 0.72 12.5 6.9 54.3 2.3 0.80 13.8 7.3 64.7 2.1 0.78 16 7.5 73.7 2.4 0.77 23 7.3 108 2.6 0.84 27.3 7.2 137 1.8 0.85 31 7.0 160 3.2 0.85 38 7.1 194 3.0 0.84 56 7.0 290 2.9 0.87 66 7.2 357 2.6 0.88 79 6.7 435 1.5 0.88 87 7.0 483 1.4 0.88 106 7.6 600 1.5 0.84 130 7.2 693 1.3 0.87 148 7.3 819 1.3 0.86 177 6.7 963 1.2 0.86 212 7.6 1156 1.3 0.84 268 6.8 1442 1.3 0.86 315 7.2 1729 1.3 0.85 405 7.1 2211 1.3 0.85 458 7.1 2500 1.4 0.84 532 6.9 2879 1.3 0.84 532 6.9 2879 1.3 0.84 620 7.4 3359 1.4 0.84 620 7.4 3359 1.4
Moment Sound pressure Time of inertia 2 tE 50 J = 1/4 GD Weight level LPA Hz kgm2 kg dB 20 20 0 0 20 18 20 17 0 14 18 7 9 23 17 7 10 13 9 6 7 6 14 5 6 5 6 6 6 6 6 6 0.0022 0.0022 0.0037 0.0048 0.012 0.014 0.032 0.034 0.039 0.088 0.126 0.126 0.25 0.47 0.52 0.78 1.6 1.85 2.2 2.85 3.2 4.1 4.9 5.8 7.9 9.7 13.5 15.5 17 17 20.5 20.5
Is / IN
29 29 41 44 60 63 96 98 105 220 247 247 298 290 305 380 465 605 645 725 830 930 1000 1150 1510 1680 2180 2500 2900 2900 3150 3150
50 50 44 44 54 54 57 57 62 57 65 65 67 65 65 64 65 66 66 66 72 72 72 72 75 75 75 75 76 76 76 76
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
Output kW Motor type Product code 750 r/min = 8 poles 400 V 50 Hz 0.18 M3HP 80 MA 3GHP 084 310-H 0.25 M3HP 80 MB 3GHP 084 320-H 0.37 M3HP 90 SLA 3GHP 094 010-H 0.55 M3HP 90 SLC 3GHP 094 030-H 0.75 M3HP 100 LA 3GHP 104 510-H 1.1 M3HP 100 LB 3GHP 104 520-H 1.5 M3HP 112 MC 3GHP 114 330-H 2.2 M3HP 132 SMC 3GHP 134 230-H 3 M3HP 132 SMD 3GHP 134 240-H 3.5 M3HP 160 MLA 3GHP 164 410-H 4.8 M3HP 160 MLB 3GHP 164 420-H 6.6 M3HP 160 MLC 3GHP 164 430-H 9.7 M3HP 180 MLB 3GHP 184 420-H 15 M3HP 200 MLB 3GHP 204 420-G 22 M3HP 225 SMC 3GHP 224 230-G 27 M3HP 250 SMA 3GHP 254 210-G 32 M3HP 250 SMB 3GHP 254 220-G 37 M3HP 280 SMA 3GHP 284 210-G 45 M3HP 280 SMB 3GHP 284 220-G 55 M3HP 280 SMC 3GHP 284 230-G 75 M3HP 315 SMB 3GHP 314 220-G 90 M3HP 315 SMC 3GHP 314 230-G 105 M3HP 315 MLA 3GHP 314 410-G 132 M3HP 355 SMB 3GHP 354 220-G 150 M3HP 355 SMC 3GHP 354 230-G 180 M3HP 355 MLB 3GHP 354 420-G 215 M3HP 355 LKB 3GHP 354 820-G 230 M3HP 400 LA 3GHP 404 510-G 230 M3HP 400 LKA 3GHP 404 810-G 280 M3HP 400 LB 3GHP 404 520-G 280 M3HP 400 LKB 3GHP 404 820-G 315 M3HP 400 LC 3GHP 404 530-G 315 M3HP 400 LKC 3GHP 404 830-G
Power IN Is Tl TN factor cos A IN Nm TN CENELEC-design 0.48 0.88 3.3 2.3 3.7 0.58 0.97 3.2 3.3 2.6 0.63 1.26 3.0 5 2.0 0.61 1.89 3.1 7.5 2.2 0.59 2.4 3.8 9.9 2.0 0.57 3.6 3.7 14.6 2.1 0.59 4.7 3.5 20 2.0 0.65 6 4.7 29.1 2.0 0.70 7.7 4.1 40.3 1.7 0.69 8.6 5.4 46.4 1.8 0.70 12 5.9 63.3 2.0 0.71 16 5.6 87.7 1.8 0.79 21 6.0 128 1.7 0.81 30.5 7.1 194 2.2 0.82 43 6.8 285 2.1 0.83 51 6.6 350 1.9 0.83 61 7.0 414 2.0 0.80 72 6.7 476 1.5 0.82 85 6.4 582 1.3 0.80 105 7.8 708 1.6 0.80 145 6.5 963 1.1 0.80 172 6.9 1156 1.2 0.80 200 7.2 1349 1.2 0.83 241 7.6 1694 1.3 0.80 283 7.3 1925 1.3 0.82 330 6.7 2313 1.2 0.81 400 7.5 2759 1.3 0.82 420 7.0 2948 1.2 0.82 420 7.0 2948 1.2 0.83 505 6.7 3593 1.1 0.83 505 6.7 3593 1.1 0.83 566 6.8 4043 1.2 0.83 566 6.8 4043 1.2
29 29 41 43 60 60 64 98 100 245 245 245 292 300 375 420 465 605 645 725 930 1000 1150 1680 1820 2180 2600 2900 2900 3200 3200 3400 3400
36 36 36 36 54 54 54 59 59 55 55 55 63 64 65 65 65 65 65 65 62 64 72 75 75 75 75 71 71 71 71 71 71
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
Increased safety cast iron motors Technical data for Ex e II T3 Gb according to VIK
IP 55, IC 411; Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034--2-1; 2007 Output 3/4 1/2 Full Speed load load load r/min 100% 75% 50% 91.0 90.5 92.5 91.0 93.2 93.8 91.8 92.9 93.4 93.5 93.7 94.1 94.7 95.0 90.5 91.7 91.5 91.9 93.0 92.3 93.4 94.4 94.4 94.5 95.0 95.2 95.2 95.6 87.4 88.0 89.9 91.8 92.4 93.0 93.8 93.1 93.4 94.2 94.2 94.4 94.9 90.5 88.4 90.5 92.6 91.1 93.2 93.8 91.2 92.7 92.8 93.3 92.9 93.6 94.5 94.9 90.9 92.0 91.7 92.1 93.2 92.3 93.5 94.6 94.5 94.9 95.0 95.3 95.4 95.7 87.8 88.4 90.7 92.0 92.9 93.1 94.1 93.5 93.8 94.4 94.5 94.7 95.1 89.4 92.2 90.2 92.2 92.9 89.1 91.1 91.0 91.9 91.0 92.0 93.5 94.1 90.2 91.2 90.9 91.3 92.5 91.3 92.8 94.1 93.7 94.6 94.4 94.8 95.1 95.3 86.9 87.4 89.2 91.1 92.3 92.3 93.4 93.1 93.7 93.9 94.2 94.4 94.8 Current Torque Tb TN 3.7 3.7 4.5 3.0 3.9 3.9 3.1 2.7 3.0 2.8 2.8 2.7 2.7 2.8 3.4 3.6 3.3 3.2 3.2 2.6 3.1 3.0 2.9 2.9 2.9 2.9 2.7 2.8 3.4 3.7 3.0 3.3 2.7 3.4 3.0 2.7 2.7 2.5 2.3 2.4 2.5
IE2
kW Motor type Product code 3000 r/min = 2 poles 400 V 50 Hz 7.5 M3HP 160 MLB 3GHP 161 420-H 2943 10 M3HP 160 MLC 12.5 M3HP 160 MLD 15 M3HP 180 MLB 20 M3HP 200 MLC 24 M3HP 200 MLE 28 1) M3HP 225 SMC 36 M3HP 250 SMB 47 2) M3HP 280 SMA 58 2) M3HP 280 SMB 68 2) M3HP 315 SMA 80 2) M3HP 315 SMB 110 2) M3HP 315 SMC 125 2) M3HP 315 MLA 1500 r/min = 4 poles 10 M3HP 160 MLC 13.5 M3HP 160 MLE 15 M3HP 180 MLB 17.5 M3HP 180 MLC 24 M3HP 200 MLA 30 M3HP 225 SMB 36 M3HP 225 SMC 44 M3HP 250 SMB 58 M3HP 280 SMA 70 M3HP 280 SMB 84 M3HP 315 SMA 100 M3HP 315 SMB 115 M3HP 315 SMC 135 M3HP 315 MLA 1000 r/min = 6 poles 6.6 M3HP 160 MLA 9.7 1) M3HP 160 MLC 13.2 M3HP 180 MLB 16.5 M3HP 200 MLB 20 M3HP 200 MLC 27 M3HP 225 SMC 33 M3HP 250 SMB 40 M3HP 280 SMA 46 M3HP 280 SMB 64 M3HP 315 SMA 76 M3HP 315 SMB 92 M3HP 315 SMC 110 M3HP 315 MLA
1) 2)
Power IN Is Tl TN factor cos A IN Nm TN CENELEC-design 0.91 13.2 7.6 24.3 3.0 0.92 0.91 0.91 0.90 0.90 0.91 0.91 0.91 0.92 0.90 0.91 0.91 0.92 0.84 0.84 0.83 0.84 0.88 0.89 0.90 0.89 0.88 0.89 0.88 0.88 0.89 0.89 0.80 0.79 0.81 0.85 0.85 0.83 0.87 0.88 0.88 0.85 0.87 0.85 0.86 17.8 7.5 32.5 21.4 7.6 40.5 26 7.1 48.6 35 7.5 64.5 42 7.2 77.4 49 7.0 90.2 61 7.2 115 80 7.1 150 97 7.0 186 116 7.2 217 134 7.0 256 183 7.0 352 205 7.6 400 CENELEC-design 19.5 7.3 65.2 26 8.0 87.6 29.5 6.9 97.2 33 7.4 113 44 7.7 154 54 7.2 193 64 7.4 232 77 6.8 283 100 7.6 373 120 7.2 450 145 7.0 538 171 7.6 641 196 6.7 738 227 7.4 865 CENELEC-design 13.8 7.3 64.7 20 7.1 95.3 26.1 7.4 130 31 7.0 160 38 7.1 194 50 8.0 261 59 7.4 318 70 6.7 387 80 7.0 444 114 7.1 616 133 7.3 731 164 7.2 885 193 7.6 1058 2.9 2.8 2.2 2.9 3.0 2.1 1.9 1.2 1.2 0.9 0.8 0.9 1.0 2.8 3.0 2.6 2.7 2.0 1.8 1.7 1.3 1.3 1.4 1.2 1.2 1.1 1.3 2.1 2.4 1.7 3.2 3.0 3.2 2.8 1.2 1.3 1.2 1.2 1.3 1.3
Moment Time of inertia tE 50 J = 1/4 GD2 Weight Hz kgm2 kg 18 12 8 15 10 9 14 11 17 12 10 10 8 10 16 14 12 15 14 17 8 15 8 7 14 10 10 7 14 11 12 25 16 11 10 15 11 10 8 15 7 0.052 0.062 0.07 0.13 0.21 0.22 0.34 0.66 0.8 0.9 1.2 1.4 1.7 2.1 0.096 0.13 0.21 0.248 0.3 0.45 0.53 0.98 1.25 1.5 2.3 2.6 2.9 3.5 0.088 0.126 0.25 0.47 0.52 0.78 1.6 1.85 2.2 3.2 4.1 4.9 5.8
Is / IN
216 227 233 292 305 310 385 475 625 665 880 940 1025 1190 226 249 279 298 280 365 390 470 625 665 900 960 1000 1160 220 247 298 290 305 380 465 605 645 830 930 1000 1150
3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 400 V 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 400 V 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP 3GHP
161 430-H 161 440-H 181 420-H 201 430-G 201 450-G 221 230-G 251 220-G 281 210-G 281 220-G 311 210-G 311 220-G 311 230-G 311 410-G 50 Hz 162 430-H 162 450-H 182 420-H 182 430-H 202 410-G 222 220-G 222 230-G 252 220-G 282 210-G 282 220-G 312 210-G 312 220-G 312 230-G 312 410-G 50 Hz 163 410-H 163 430-H 183 420-H 203 420-G 203 430-G 223 230-G 253 220-G 283 210-G 283 220-G 313 210-G 313 220-G 313 230-G 313 410-G
2938 2944 2947 2960 2959 2963 2969 2982 2975 2982 2980 2978 2983 1463 1470 1473 1477 1480 1481 1480 1482 1484 1484 1489 1489 1488 1489 973 971 965 984 983 987 989 987 988 992 992 992 992
Efciency class IE1 3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
100 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Increased safety cast iron motors Technical data for Ex e II T3 Gb according to VIK
Power IN Is Tl TN factor cos A IN Nm TN CENELEC-design 0.69 8.6 5.4 46.4 1.8 0.70 11.5 5.9 63.3 2.0 0.71 15.6 5.6 87.7 1.8 0.79 21 6.0 128 1.7 0.83 26 6.1 171 1.8 0.81 33 6.6 214 2.0 0.82 39 6.9 259 2.1 0.83 51 6.6 350 1.9 0.80 64 6.9 425 1.4 0.80 77 7.0 515 1.5 0.82 93 7.1 643 1.2 0.79 131 7.2 872 1.2 0.80 152 7.7 1026 1.3 0.81 178 7.1 1220 1.1
Moment Time of inertia tE 50 J = 1/4 GD2 Weight Hz kgm2 kg 20 20 17 20 32 25 24 16 12 15 15 12 10 7 0.133 0.133 0.133 0.245 0.54 0.68 0.75 1.25 1.85 2.2 3.2 4.1 4.9 5.8
Is / IN
245 245 245 292 300 350 375 420 605 645 830 930 1000 1150
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 101
Balancing 052 417 423 424 Vibration acc. to Grade A (IEC 60034-14). Vibration acc. to Grade B (IEC 60034-14). Balanced without key. Full key balancing. S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P
Bearings and Lubrication 036 037 040 041 043 058 107 128 129 130 194 433 506 654 795 796 797 798 799 800 Brakes 412 Built-on brake. R R R R R R R R NA NA NA NA NA NA Transport lock for bearings. Roller bearing at D-end. Heat resistant grease. Bearings regreasable via grease nipples. SPM compatible nipples for vibration measurement Angular contact bearing at D-end, shaft force away from bearing. Pt100 2-wire in bearings. Double Pt100, 2-wire in bearings Double Pt100, 3-wire in bearings Pt100 3-wire in bearings. 2Z bearings greased for life at both ends. Outlet grease collector Nipples for vibration measurement: SKF Marlin Quick Connect stud CMSS-2600-3 Provision for vibration sensors (M8x1) Lubrication information plate Grease nipples JIS B 1575 Pt 1/8 Type A Stainless steel SPM Nipples Stainless steel grease nipples Grease nipples at type DIN 3404, thread M10x1 Grease nipples JIS B 1575 Pt 1/8" pin type NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P S P P P P P P S P P P P P P S P P P P P P S P P P P P NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P NA NA S NA NA NA NA NA S NA NA NA NA NA S NA NA NA NA NA S NA NA NA NA NA S NA NA NA P P P S S P P P P S S P P P P S S P P P P S S P P P P S S P P P P S S P P P P S S P P P P S S P P P P S S P
Branch standard designs 178 204 209 425 786 Stainless steel / acid proof bolts. Jacking bolts for foot mounted motors. Non-standard voltage or frequency, (special winding). Corrosion protected stator and rotor core. Special design shaft upwards (V3, V36, V6) for outdoor mounting. Cooling system 044 Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors.
1)
S NA P S P
S NA P S P
S NA P S P
S NA P S P
S NA P S P
P P P S P
P P P S P
P P P S P
P P P S P
P P P S P
P P P P R
P P P P R
P S P P NA
P S P P NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
102 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant
Frame size 80 90 NA 100 NA 112 NA 132 NA 160 NA 180 NA 200 NA 225 NA 250 NA 280 P 315 P 355 P 400 P
045
Unidirectional fan for reduced noise level. Rotation counter clockwise seen from D-end. Available only for 2-pole motors.
NA
Light alloy metal fan Steel fan Separate motor cooling (fan top, N-end). Stainless steel fan cover
P NA NA NA
P NA NA NA
P NA NA NA
P NA NA NA
P NA NA NA
P P NA NA
P P NA NA
P P NA NA
P P NA P
P P NA P
P P R P
P P R P
P P R P
P P R P
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Drain holes 065 448 Plugged existing drain holes. Draining holes with metal plugs. NA NA NA NA NA NA NA NA NA NA P P P P P P P P P P P P P P P P P P
Hazardous Environments 272 Ex e II acc. to ATEX directive 94/9/EC, temp. class T2. NA NA NA NA NA P P P P P P P P P
Heating elements 450 451 Heating element, 100-120 V Heating element, 200-240 V P P P P P P P P P P P P P P P P P P P P P P P P P P P P
Mounting arrangements 008 009 047 066 IM 2101 foot/ange mounted, IEC ange, from IM 1001 (B34 from B3). IM 2001 foot/ange mounted, IEC ange, from IM 1001 (B35 from B3). IM 3601 ange mounted, IEC ange, from IM 3001 (B14 from B5). Modied for specied mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001) & IM B34 (2101) 228 229 235 236 245 246 255 256 257 258 259 260 Painting 105 111 114
1)
P P P P
P P P P
P P P P
P P P P
P P P P
NA P NA P
NA P NA P
NA P NA P
NA P NA P
NA P NA P
NA P NA P
NA P NA P
NA P NA P
NA P NA P
Flange FF 130. Flange FT 130. Flange FF 165. Flange FT 165. Flange FF 215. Flange FT 215. Flange FF 265. Flange FT 265. Flange FF 100. Flange FT 100. Flange FF 115. Flange FT 115.
P P S P NA NA NA NA P P P P
P P S P NA NA NA NA P P P P
P P P P S P NA NA NA NA NA NA
P P P P S P NA NA NA NA NA NA
NA NA P P P P S P NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA
Paint thickness report. Painting system C3M acc. to ISO 12944-5:2007 Special paint colour, standard grade.
P S P
P S P
P S P
P S P
P S P
P S P
P S P
P S P
P S P
P S P
P S P
P S P
P S P
P S P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 103
Code 1)
Variant
Frame size 80 90 P P P P P 100 P P P P P 112 P P P P P 132 P P P P P 160 P P P P P 180 P P P P P 200 P P P P P 225 P P P P P 250 P P P P P 280 P P P P P 315 P P P P P 355 P P P P P 400 P P P P P
Painting system C4M acc. to ISO 12944-5:2007 Primer paint only. Painted insulation layer on inside of the terminal boxes. Thermally sprayed zink metallizing with acrylic top coat Painting system C5M acc. to ISO 12944-5:2007
P P P P P
Protection 005 072 073 076 158 401 403 434 783 Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Sealed against oil at D-end. Draining holes with plugs in open position. Degree of protection IP 65. Protective roof, horizontal motor. Degree of protection IP 56. Degree of protection IP 56, open deck. Labyrinth sealing at D-end. P P P P P P P NA P P P P P P P P NA P P P P P P P P NA P P P P P P P P NA P P P P P P P P NA P P P P S P P P P P P P P S P P P P P P P P S P P P P P P P P S P P P P P P P P S P P P P P P NA P S P P P P P P NA P S P P P P P P NA NA S P P P P S P NA NA S P P P P S
Rating & instruction plates 002 004 126 135 139 159 161 Restamping voltage, frequency and output, continuous duty. Additional text on std rating plate (max 12 digits on free text line). Tag plate Mounting of additional identication plate, stainless. Additional identication plate delivered loose. Additional plate with text "Made in ...." Additional rating plate delivered loose. P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P
Shaft & rotor 069 070 164 165 410 Two shaft extensions as per basic catalogue. One or two special shaft extensions, standard shaft material. Shaft extension with closed key-way. Shaft extension with open key-way. Stainless steel shaft (standard or non-standard design). Standards and Regulations 151 421 482 504 Design according to SHELL DEP 33.66.05.31-Gen. June 2007 VIK design (Verband der Industriellen Energie- und Kraftwirtschaft e.V.). Design according to Neste OY & Jacobs, specication N-114 E, rev 5, 1.12.2010 Design according to Neste OY & Jacobs, specication N-114 E, rev 5, 01.12.2010 with SPM adapter 505 VIK design with ABB standard shaft dimensions (Verband der Industriellen Energie- und Kraftwirtschaft e.V.).
1)
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P S P R
P P P S P
P P P S P
P P P S P
P P P S P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
104 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant
Frame size 80 90 P P 100 P P 112 P P 132 P P 160 P P 180 P P 200 P P 225 P P 250 P P 280 P P 315 P P 355 P P 400 P P
775 779
Design according to SHELL DEP 33.66.05.31-Gen. January 1999 design. SASO Export/Import Certicate (Saudi Arabia)
P P
Stator winding temperature sensors 435 440 445 446 502 503 511 PTC - thermistors (3 in series), 130 C, in stator winding. PTC - thermistors (3 in series, 110 C & 3 in series, 130C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Pt-100 2-wire in stator winding, 2 per phase Pt-100 3-wire in stator winding, 1 per phase. Pt-100 3-wire in stator winding, 2 per phase. PTC thermistors (2 x 3 in series), 130 C, in stator winding Terminal box 021 022 157 180 277 278 279 292 293 294 295 380 400 402 413 418 466 468 469 567 568 729 730 732 733 736 737 743
1)
S P P NA NA NA P
S P P NA NA NA P
S P P NA NA NA P
S P P NA NA NA P
S P P NA NA NA P
S P P P P P P
S P P P P P P
S P P P P P P
S P P P P P P
S P P P P P P
S P P P P P P
S P P P P P P
S P P P P P P
S P P P P P P
Terminal box LHS (seen from D-end). Cable entry LHS (seen from D-end). Terminal box degree of protection IP65. Terminal box RHS (seen from D-end). Cable sealing end unit, size small for C-opening Cable sealing end unit, size medium for D-opening Cable sealing end unit, size large for D-opening Adapter C-C Adapter D-D Adapter E-D Adapter E-2D Separate terminal box for temperature detectors, std. material 4 x 90 degr turnable terminal box. Terminal box adapted for Al cables. Extended cable connection, no terminal box. Separate terminal box for auxiliaries, standard material. Terminal box at N-end. Cable entry from D-end. Cable entry from N-end. Separate terminal box material: Cast Iron Separate terminal box for heating elements, std. material Aluminum non-drilled ange for cable glands Prepared for NPT cable glands Standard cable gland, Ex d IIB, armoured cable. Standard cable gland, Ex d IIB, non-armoured cable. Standard cable gland Ex e acc. to EN-standards. Standard cable gland Ex e with clamping device acc. to EN-standards. Painted non-drilled ange in steel for cable glands
NA P P NA NA NA NA NA NA NA NA NA S NA NA NA NA P P NA NA P P P P S P P
NA P P NA NA NA NA NA NA NA NA NA S NA NA NA NA P P NA NA P P P P S P P
NA P P NA NA NA NA NA NA NA NA NA S NA NA NA NA P P NA NA P P P P S P P
NA P P NA NA NA NA NA NA NA NA NA S NA NA NA NA P P NA NA P P P P S P P
NA P P NA NA NA NA NA NA NA NA NA S NA NA NA NA P P NA NA P P P P S P P
P P P P NA NA NA NA NA NA NA P S NA P P NA P P S P P P P P S P P
P P P P NA NA NA NA NA NA NA P S NA P P NA P P S P P P P P S P P
P P P P NA NA NA NA NA NA NA P S NA P P P P P P P P P P P S P P
P P P P NA NA NA NA NA NA NA P S NA P P P P P P P P P P P S P P
P P P P NA NA NA NA NA NA NA P S NA P P P P P P P P P P P S P P
P P P P P NA NA P NA NA NA P S S P P P P P P P P P P P S P P
P P P P NA P P NA P P P P S S P P P P P P P P P P P S P P
P P P P NA P P NA P P P P NA S P P P R R P P P P P P S P P
P P P P NA P P NA NA P P P NA S P P P R R P P P P P P S P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 105
Code 1)
Variant
Frame size 80 90 P P P 100 P P P 112 P P P 132 P P P 160 P P P 180 P P P 200 P P P 225 P P P 250 P P P 280 P P P 315 P P P 355 P P P 400 P P P
Stainless steel non-drilled ange for cable glands. Painted steel ange equipped with nickle plated brass cable glands Stainless steel cable ange equipped with standard nickle plated brass cable glands
P P P
Type test report from a catalogue motor, 400 V 50 Hz. Type test with report for one motor from specic delivery batch. Routine test report. Customer witnessed testing. Specify test procedure with other codes. Torque/speed curve, type test and multi-point load test with report for one motor from specic delivery batch.
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
P P P P P
Vibration level test Vibration spectrum test for one motor from specic delivery batch. Noise level test for one motor from specic delivery batch. Noise spectrum test for one motor from specic delivery batch.
P P P R
P P P R
P P P R
P P P R
P P P R
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
P P P P
1)
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
106 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
D GA
F
M000269 M000198 M000199 M000200
Sizes 80 to 200
Motor size 80 90 100 112 132 160 180 200 225 250 280 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_
IM 1001, IM B3 AND IM 3001, IM B5 D GA F E poles poles poles poles 2 19 24 28 28 38 42 48 55 55 60 65 65 65 70 70 70 80 80 4-8 2 19 24 28 28 38 42 48 55 60 65 75 80 90 100 100 100 110 100 21.5 27 31 31 41 45 51.5 59 59 64 69 69 69 62.5 62.5 62.5 85 85 4-8 21.5 27 31 31 41 45 51.5 59 64 69 79.5 85 95 90 90 90 126 106 2 6 8 8 8 10 12 14 16 16 18 18 18 18 20 20 20 22 22 4-8 2 6 8 8 8 10 12 14 16 18 18 20 22 25 28 28 28 28 28 40 50 60 60 80 110 110 110 110 140 140 140 140 140 140 140 170 170 4-8 40 50 60 60 80 110 110 110 140 140 140 170 170 210 210 210 210 210
L max poles 2 340 405 480 480 560 808 826 774 841 875 1088 1174 1285 1409 1514 1764 1851 1851 4-8 340 405 480 480 560 808 826 774 871 875 1088 1204 1315 1479 1584 1834 1891 1891
IM 1001, IM B3 A B B C
HD
IM 3001, IM B5 M N P
Protective roof DS LS poles 2 4-8 360 430 505 505 590 756 756 844 951 965 1190 1320 1431 1546 1703 1703 1900 1900 160 180 195 195 260 328 359 414 462 506 555 624 624 720 720 720 810 810 360 430 505 505 590 756 756 844 921 965 1190 1290 1401 1476 1528 1633 1860 1860
125 140 160 190 216 254 279 318 356 406 457 508 508 610 610 610 710 686
100 100 140 140 140 210 241 267 286 311 368 406 457 500 560 710 900 710
125 125 178 254 279 305 311 349 419 457 508 560 630 900 1000 800
50 56 63 70 89 108 121 133 149 168 190 216 216 254 254 254 224 280
235 260 280 295 340 499 539 536 583 646 759 852 852 958 958 958 1045 1045
80 90 100 112 132 160 180 200 225 250 280 315 315 355 355 355 400 400
165 165 215 215 265 300 300 350 400 500 500 600 600 740 740 740 940 740
130 130 180 180 230 250 250 300 350 450 450 550 550 680 680 680 880 680
200 200 250 250 300 350 350 400 450 550 550 660 660 800 800 800 1000 800
Tolerances: A, B D, DA F, FA H N C, CA 0,8 ISO k6 < 50mm ISO m6 > 50mm ISO h9 -0.5 ISO j6 0.8
Above table gives the main dimensions in mm. For detailed drawings please see our web-pages www.abb.com/motors&generators or contact ABB.
S = Standard ange
M = Modication
NA = Not applicable
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 107
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Stator frame Endshield, D-end Screws for endshield, D-end Endshield, N-end Screws for endshield, N-end Rotor with shaft Key, D-end Terminal box Terminal board Intermediate flange Screws for terminal box cover Outer bearing cover, D-end Valve disc with labyrinth seal, D-end; standard in 2-pole motors (V-ring in 4-8 pole) Bearing, D-end Inner bearing cover, D-end Screws for bearing cover, D-end
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Outer bearing cover, N-end Seal, N-end Wave spring (280-315) Coil spring (355-400) Valve disc, N-end Bearing, N-end Inner bearing cover, N-end Screws for bearing cover, N-end Fan Fan cover Screws for fan cover Rating plate Regreasing plate Grease nipple, D-end Grease nipple, N-end SPM nipple, D-end SPM nipple, N-end
108 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000220
Certicate examples
M000728
2(2)
2011-06-22 Certificates: 3-phase induction motors, series M2GP, M3JP, M3KP, M3GP, M3HP, M3LP
Motor type, IEC frame size M3JP/M3KP 80 M3JP/M3KP 90 M3JP/M3KP 100-112 M3JP/M3KP 132 M3JP/M3KP 160 M3JP/M3KP 180 M3JP/M3KP 160 Gen.H M3JP/M3KP 180 Gen.H M3JP/M3KP 200 M3JP/M3KP 225 M3JP/M3KP 250 M3JP/M3KP 280 M3JP/M3KP 315 M3JP/M3KP 355 M3JP/M3KP 400 M3HP 80-90 M3HP 100-112 M3HP 132 M3HP 160 M3HP 180 M3HP 160 Gen.H M3HP 180 Gen.H M3HP 200 M3HP 225 M3HP 250 M3HP 280 M3HP 315 M3HP 355 M3HP 400 M2GP 71-250 M3GP 80 - 400 M3GP 160 - 180 Gen.H M3GP/M3LP 450 M3GP 160 180 Gen.H IP 65 M3GP 160 180 Gen.H M3GP/M3LP 450 M2GP 71-250 M3GP 80-400 LCIE 09 ATEX 1010 * LCIE 06 ATEX 6088 LCIE 05 ATEX 6160 LCIE 06 ATEX 6089 2009 2006 2005 2006 Certification number LCIE 04 ATEX 6150 LCIE 04 ATEX 6151 LCIE 04 ATEX 6152 LCIE 04 ATEX 6061 LCIE 00 ATEX 6023 LCIE 00 ATEX 6028 LCIE 09 ATEX 3004X LCIE 09 ATEX 3005X LCIE 00 ATEX 6027 LCIE 00 ATEX 6029 LCIE 00 ATEX 6030 LCIE 01 ATEX 6078 LCIE 01 ATEX 6079 LCIE 03 ATEX 6060 LCIE 04 ATEX 6087 LCIE 06 ATEX 6047 LCIE 06 ATEX 6048 LCIE 06 ATEX 6049 LCIE 01 ATEX 6015 LCIE 01 ATEX 6021 LCIE 09 ATEX 3022 LCIE 09 ATEX 3023 LCIE 01 ATEX 6022 LCIE 01 ATEX 6023 LCIE 01 ATEX 6024 LCIE 02 ATEX 6071 LCIE 02 ATEX 6072 LCIE 03 ATEX 6022 LCIE 04 ATEX 6013 LCIE 05 ATEX 6160 LCIE 06 ATEX 6089 LCIE 09 ATEX 1010 * LCIE 06 ATEX 6088 LCIE 09 ATEX 3016 Year of CE-marking 2004 2004 2004 2004 2000 2000 2009 2009 2000 2000 2000 2001 2001 2003 2004 2006 2006 2006 2001 2001 2009 2009 2001 2001 2001 2002 2002 2003 2004 2005 2006 2009 2006 2009
EC Declaration of Conformity
The Manufacturer: ABB Oy Motors Motors and Generators P.O. Box 633 Strmbergin puistotie 5A FIN - 65101 Vaasa, Finland
hereby declares that the products: 3-phase induction motors, series M2GP, M3JP, M3JC, M3KP, M3KC, M3GP, M3HP and M3LP; as listed on page 2 in this document, fulfill provisions of the relevant Council Directives:
rd
In addition: II 2 D Ex tD A21 / IP 65 or II 3 D Ex tD A22 / IP 55, IP65 (3D not for M3JP/KP160-180 Gen.H)
Increased safety
- that the state of the art of these standards do not modify the result of the assessment carried out by LCIE which issued the EC type examination certificates according to former editions of the standard series. - that listed motors conform to the requirements of annex II of the directive 94/9/EC clause 1.2.7 by applying the standards series EN 60034. Directive 2009/125/EC (EuP of 21st October 2009) by fulfilling the requirements of the standard IEC 60034-30: 2008 Ed 1 in respect of the efficiency class. Note: When installing motors for converter supply applications additional requirements must be respected regarding the motor as well as the installation, as described in the appropriate dedicated addendum.
Signed by
Non-sparking II 3G Ex nA II T2 -T3
Title Date
ABB Oy
Motors and Generators Postal address P.O. Box 633 FI-65101 Vaasa FINLAND Visiting Address Strmbergin Puistotie 5 A FI-65320 Vaasa FINLAND Telephone +358 10 22 11 Telefax +358 10 22 47372 Internet www.abb.fi e-mail: first name.last name @fi.abb.com Business Identity Code: 0763403-0 Domicile: Helsinki
M000725-1a
1) 2)
Notified Body ( ExNB ): LCIE (0081) ; Av. Du Gnral Leclerc. 33, 92266 Fontenay-aux-Roses, France *) Voluntary Type Examination Certificate for equipment category 3
3GZF500930-988
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 109
M000725-2a
Increased safety motors with cast iron frame in brief, basic design
Motor size Stator Material Paint colour shade Corrosion class Feet Bearing end shields Material Paint colour shade Corrosion class Bearings D-end N-end Axially-locked bearings Bearing seal Lubrication SPM-nipples Rating plate Terminal box Material Frame material Cover material Cover screws material 2-12 pole 2-12 pole 80 90 100 112 132 160 180 Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Forged steel, detachable feet Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6204-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3 6208-2Z/C3 6309/C3 6309/C3 6310/C3 6310/C3
As standard, locked at D-end Gamma-ring as standard Permanent grease lubrication. Stainless steel Cast iron, EN-GJL-200 or better Cast iron, EN-GJL-200 or better Acidproof steel A4-80 Steel 8.8, zinc electroplated and chromated. Regreasable bearings As standard
Connections
1 x M25 x 1.5
2 x M32 x 1.5
2 x M40 x 1.5
6 terminals for connection with cable lugs (not included Polyamide. Reinforced with glass bre. Polypropylene. Reinforced with glass bre.
Fan
Material
Fan cover
Steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors as standard Pressure die-cast aluminum Half key balancing Closed
Stator winding
Material
On request
As standard IP 55 IC 411
110 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Increased safety motors with cast iron frame in brief, basic design
Motor size Stator Material Paint colour shade Corrosion class Feet Bearing end shields Material Paint colour shade Corrosion class Bearings D-end 2-pole 4-12 -pole N-end 2-pole 4-12 -pole Axially-locked bearings Bearing seal Lubrication SPM-nipples Rating plate Terminal box Material Frame material Cover material Cover screws material Connections Cable entries Terminals Fan Material Inner bearing cover 200 225 250 280 315 355 400 Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Cast iron, EN-GJL-200 or better, integrated with stator Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6312M/C3 6312/C3 6310M/C3 6310/C3 6313M/C3 6313/C3 6312M/C3 6312/C3 6315M/C3 6315/C3 6313M/C3 6313/C3 6316/C3 6316/C3 6316/C3 6319/C3 6316M/C3 6322/C3 6316M/C3 6317M/C3 6324/C3 6317M/C3 6319/C3
As standard, locked at D-end Gamma ring Regreasable bearings As standard Stainless steel Cast iron, EN-GJL-200 or better Cast iron, EN-GJL-200 or better Steel 8.8, zinc electroplated and chromated 2 x M50 x 1.5 2 x M63 x 1,5 Refer to table on page 85 V-ring or labyrinth seal, refer to table on page 84
6 terminals for connection with cable lugs (not included) Polypropylene. Reinforced with glass bre. Polypropylene reinforced with glass bre or aluminum.
Fan cover
Hot dip galvanized steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors as standard Pressure die-cast aluminum Half key balancing
Stator winding
Rotor winding Balancing Heating elements Key way Drain holes External earthing bolt Enclosure Cooling method
Material
On request
25 W Closed
60 W Open
120 W
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 111
112 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Non-sparking motors Ex nA Totally enclosed squirrel cage three phase low voltage motors, Sizes 71 to 450, 0.25 to 1000 kW
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 113
Mechanical design
Drain holes
Non-sparking Ex nA motors in frame sizes 71 to 132 and 200 to 450 are fitted with drain holes and plugs as standard. Drain holes and plugs are available for frame sizes 160 to 180 as an option. Please see variant code section.
Closed
Open
M000178
Open
Bearing seals
The following bearing seals are used as standars special seals like radial seal are available as option. Please see variant code section.
Bearing seals in Ex nA (M3GP) IE2 cast iron motors Frame size 71-250 280-315 280-315 355 355 400 400 450 Number of poles 2-12 2 4-12 2 4-12 2 4-12 2-12 D-end Gamma ring Labyrinth seal V-ring Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal N-end Gamma ring V-ring V-ring V-ring V-ring Labyrinth V-ring Labyrinth
Bearing seals in Ex nA (M3GP) IE3 cast iron motors Frame size 200-250 280-450 Number of poles 2-12 2-12 D-end Gamma ring Labyrinth seal N-end Gamma ring Labyrinth seal
Bearing seals in Ex nA aluminum motors (M3AAN and M3AA) Frame size 63-180 200-280 Number of poles 2-8 2-8 D-end V-ring V-ring N-end Labyrinth seal V-ring
114 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
If no ordering information on the cable is given, it is assumed to be p.v.c. -insulated non-armoured and termination parts are supplied according below. To enable the supply of suitable terminations for the motor, please state cable type, quantity, size and outer diameter when ordering. Ex nA motors in size 160 and larger are delivered as standard with cable glands or cable sealing end units according to the below table. Different glands can be provided separately as an option. Please see Alternatives section for details. Note: For 500 V motor information please contact ABB!
tion mm2 for 6 x M4 M4 M5 M6 M10 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 M12 12 x M12 M12 12 x M12 M12
63 160 210 370 370 750 370 750 750 370 370 750 750 750 750 1200 750 1200 750
2x18-27 2x26-35 2x32-49 2x32-49 2x32-49 2x48-60 2x32-49 2x48-60 2x48-60 2x32-49 2x32-49 2x60-80 2x48-60 2x60-80 2x48-60 4x60-80 2x60-80 4x60-80 2x60-80
Earthings on motor
71-112 132 160-180 200-250 280-315 355 400 450 450 Frame M4 M5 M6 M8 M10 M10 M10 M10 M10 Terminal box M4 M5 M6 M8 2xM10 2xM10 2xM10 2xM12 2xM10 Terminal box type 63 160 210, 370 370. 750 750 1200 750
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 115
Adapters
How to order? Check first that the terminal box can allow mounting of the cable and cable cores (refer to motor type and terminal box type cross reference on the page 115). If very large cables are used, it may be neccesary to use a larger terminal box than standard. Select the right cable gland(s) or cable sealing end unit(s) depending on the outer diameter of the cable(s). Select the appropriate adapter, cable gland(s) and gland plate or cable sealing end unit. Note that turning the terminal box to a non standard position may limit the use of some adapters.
Ordering example Motor Cables 200 kW, 4 pole, 400 V 50 Hz, cables needed: 2 pieces, outer diameter 58 mm, single cross section 185 mm, cables coming from below
Needed one terminal box for anticondensation heaters (220 V) and another for temperature detectors, terminal box material cast iron. Motor Adapter Cable sealing end unit Auxiliaries M3GP 315 MLA 4, B3 D-D (variant code 293) Variant code 278 Variant codes 451, 380, 567, 568
1. Main terminal box and maximum single core cross section Larger than standard single core cross section is available as option according to the table below. Also one size larger terminal box can be selected. Check also also the capacity of the cable entry to make sure the cables fit.
Standard terminal box Terminal box type 160 210 370 750 1200 Size of opening C C D E E Max single core cross section per phase mm2 120 2 x 240 2 x 300 4 x 500 4 x 500 370 750 1200 D E E Variant code 019 larger terminal box than standard Terminal box type Size of opening Max single core cross section per phase mm2 2 x 240 2 x 300 4 x 500 -
The accessories for using the maximum single core cross sections are not included as standard. For this option please use variant code 300 (Increased single core cross section). Each terminal box has got limited maximum cable entry size, please request if necessary.
116 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000443
2. Optional adapters To allow easy termination of cables entering the terminal box from above or below , an angle adapter is recommended.
These can also be used to allow the of several cable sealing end units or gland plates on the terminal box for termination of more cables than one cable sealing end unit or gland plate can allow.
Gland plate or opening for cable sealing end unit Material Notes
Adapter
Variant code
292
M000430
Steel
293
M000431
Steel
294
M000432
Steel
295
M000433
2 pcs D
Steel
296
M000434
3 pcs D
Steel
444
M000435
2 pcs E
Steel
3. Gland plate, maxium size of glands and material Gland plates delivered blind or be drilled and tapped to accomodate glands to suit the cable diameter and amount of glands needed. Standard gland plate material is siluminium, painted steel or stainless steel are available as options.
Size C D E Maximum size and number of glands, metric 2xM90 4xM90 6xM90 3xM50 4xM63 7xM63 7xM32 7xM50 9xM50
Related variant codes: 729 Cable flanges without holes / Blank gland plates. 730 Prepared for NPT glands 732 Standard cable gland, Ex d IIB, armoured cable. 733 Standard cable gland, Ex d IIB, non-armoured cable. 743 Painted non-drilled flange in steel for cable glands. 744 Stainless steel non-drilled flange for gable glands. 745 Painted steel cable flange equipped with nickle plated brass cable glands. 746 Stainless steel cable flange equipped with nickle plated brass cable glands.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 117
4. Cable glands and cable sealing end units Cable glands The table below shows the selction of cable gland types and the possible cable outer diameter of each size. For armoured and NPT cable glands please contact ABB.
Outer diameter, mm Variant code 745 Painted steel ange equipped with brass cable glands Motor sizes 71-450: M16 M20 M25 M32 M40 M50 M63 M75 M90
Variant code 737 Standard cable gland Ex e with clamping device acc. to EN-Standards
Cable sealing end unit As an alternative to flanges and cable glands, cable sealing units can be used. These allow more space for spreading the cores for easy terminating on the terminals. Cable sealing end units have rubber sealed entries for one or two main cables. In addition are there two plugged M20 holes for auxillary cables.
M000437
Accessories Variant code Opening towards terminal box Cable outer diameter mm Cable entry auxiliary cable Variant code 704; EMC cable gland Variant code 231; Standard cable gland with clamping device
M000436
277
1 or 2 pcs 48-60 mm *)
Optional
Optional
M000437
278
1 or 2 pcs 48-60 mm *)
Optional
Optional
M000438
279
1 or 2 pcs 60-80 mm *)
Optional
Optional
*) The cable seal inside the cable sealing end unit can be used so that it is suitable for cable diameters 40 -52 mm.
118 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
5. Auxiliary terminal box It's possible to equip the motors from frame size 160 upwards with one or several auxiliary terminal boxes for connection of auxiliaries like heaters or temperature detectors. The standard auxiliary terminal box is made of aluminum and equipped with M20 glands for entry of the connection cables. As an option cast iron terminal box is available. In motor sizes 160 to 180 the material of auxiliary terminal box is cast iron. Connection terminals are spring loaded type for quick and easy connection. These are suitable for up to 2.5 mm wires. Auxiliary terminal boxes are equipped with an earthing terminal. As standard the first auxiliary terminal box is located on RHS seen from D-end. Small, aluminum auxiliary terminal box (80 x 125 mm, for max. 12 wires) Earthing size M4
Related variant codes: 418 Separate terminal box for auxiliaries, standard material (all connections of temperature detectors and heaters will be put in same box) 380 Separate terminal box for temperature detectors, standard material 568 Separate terminal box for heating elements, standard material 569 Separate terminal box for brakes, standard material 567 Separate terminal box material: Cast iron
Large, aluminum auxiliary terminal box (80 x 250 mm, for max. 30 wires) Earthing M4
Cast iron auxiliary terminal box (211 x 188 mm, for max. 30 wires) Earthing M6
M000439
M000440
Standard cable entry size M20. Number of entries depends on the terminal box type and number of selected auxiliaries.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 119
M000441
M000368b
M000365
Motor sizes 280 to 315 Top- and side-mounted Terminal boxes 210, 370
M000205
M000206
Motor size 71-80 90-112 132 160-180 200-250 280-400 315-355 355-450 355-400 450 450
M000331
Terminal box
A1 105 118
B1 105 118 169 243 319 306 347 413 413 578 578
25 63 160 210 370 750 top-mounted 750 side-mounted 1200 + E-2D adapter 1200 + E-D adapter
120 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000205
M000369
M000521
M000017
M000018
M000501
Connections
The terminal block is provided with six terminals for connecting Cu-cable. The terminals are marked in accordance with IEC 60034-8. Connection openings
Motor size 71-80 90-112 132 132
1) 2)
Opening Knock-out opening Knock-out opening Knock-out opening Knock-out opening Knock-out opening 2 x FL 13 2 x FL 21
2)
Metric cable entry 2 x ( 2 x M20 ) 2 x (M25 + M20) 2 x (M25 + M20) 2 x (M40 x M32 + M12) 2 x (2 x M40 + M16) 1 x (2 x M40 + M16) 1 x (2 x M63 + M16)
Method of connection Cable lug Screw terminal Cable lug Cable lug Cable lug Cable lug Cable lug
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 121
M000500
If the radial force is applied between points X0 and X max, the permissible force FR can be calculated from the following formula:
Cast iron motors, sizes 71 to 132 Permissible radial forces according to L10 principle Non-sparking motors
Motor size No. of poles Length of shaft extension E (mm) 71 2 4 6 8 80 2 4 6 8 90 2 4 6 8 100 2 4 6 8 112 2 4 6 8 132 2 4 6 8 30 30 30 30 40 40 40 40 50 50 50 50 60 60 60 60 60 60 60 60 80 80 80 80 Basic design with deep groove ball bearings 25,000 hrs 40,000 hrs FXo(N) 680 680 680 680 930 930 930 930 1010 1010 1010 1010 1755 1755 1755 1755 1755 1755 1755 1755 2120 2120 2120 2120 FXmax(N) 570 570 570 570 750 750 750 750 810 810 810 810 1385 1385 1385 1385 1385 1385 1385 1385 1610 1610 1610 1610 FXo(N) 680 680 680 680 930 930 930 930 1010 1010 1010 1010 1755 1755 1755 1755 1755 1755 1755 1755 2120 2120 2120 2120 FXmax(N) 570 570 570 570 750 750 750 750 810 810 810 810 1385 1385 1385 1385 1385 1385 1385 1385 1610 1610 1610 1610
122 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Cast iron motors, sizes 160 to 450 Permissible radial forces according to L10 principle Non-sparking motors
Motor size Poles Length of shaft extension E (mm) 110 110 110 110 110 110 110 110 110 110 110 110 110 140 140 140 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 170 170 170 140 210 210 210 140 210 210 210 140 210 210 210 170 210 210 210 170 210 210 210 170 210 210 210 Ball bearings 40,000 hours FX0 [N] 2530 3180 3650 4020 2900 3660 4190 4620 3830 4830 5520 6080 4350 5490 6280 6920 4390 6790 7760 8550 5840 7260 8300 9150 5810 9030 10310 11360 5850 9000 10270 11330 5880 9090 10270 11360 5790 11930 13630 15050 5770 11980 13650 15090 5670 12020 13680 15160 4450 12120 13750 15280 4450 12120 13750 15280 3890 13010 14730 16480 FXmax[N] 2120 2670 3060 3370 2440 3080 3520 3880 3160 3980 4550 5010 3660 4420 5060 5570 4350 5480 6270 6900 4900 6110 6980 7700 4960 7470 8530 9400 5080 7620 8700 9590 5210 7870 8890 9840 5090 9890 11300 12470 5120 10090 11500 12710 5140 10420 11860 13150 3970 10550 11970 13310 3970 10550 11970 13310 3530 11560 13100 14640 Roller bearings 40,000 hours FX0 [N] 6400 7880 8900 9700 6970 8580 9700 10570 9500 11710 13230 14420 11650 14340 16190 17660 15420 18980 21440 23370 16500 20100 22690 24740 16540 26590 30030 32740 16710 26580 30010 32720 16900 26950 30390 33150 16790 36660 41390 45140 16880 36960 41720 45503 17030 37470 42290 46130 19390 43040 48570 52990 19390 43040 48570 52990 19430 50440 56920 62110 FXmax[N] 3160 3130 3140 3150 4380 4360 4360 4370 7100 7090 7080 7090 7090 7340 7330 7330 7360 9320 9330 9320 6350 9690 9680 9690 6280 10170 10160 10100 6200 14570 14580 14510 6080 14410 14210 14130 7470 14590 14530 14460 7110 14290 14210 14110 6570 13850 13660 13510 8760 18600 17980 18180 8760 18600 17980 18180 8200 25300 22730 22370
160 ML_
180 ML_
200 ML_
225 SM_
250 SM_
280 SM_
315 SM_
315 ML_
315 LK_
355 SM_
355 ML_
355 LK_
400 L_
400 LK_
450 L_
2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 123
FAD
FAZ
FAZ N 215 315 320 430 425 800 1440 1470 2040 2240 2100 2870 2780 2730 5460 5370 5240 5810 5810 5550
FAZ N 330 470 425 765 760 1150 2010 2130 2920 3230 3310 4140 5170 5080 9560 9440 9260 10250 10250 10450
M000022
FAZ N 410 595 605 1015 1010 1435 2440 2630 3560 3940 4160 5040 6210 6100 10860 10680 10480 11510 11410 11630
FAZ N 480 675 710 1215 1210 1645 2790 3040 4100 4540 4900 5840 7180 7070 12090 11900 11610 12630 12630 12920
71 80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
FAZ
M000023
FAD
Mounting arrangement IM V1
Motor size 40,000 hours 2-pole FAD N 530 690 775 1010 1020 150 2440 3120 3960 4570 6240 6440 6950 7280 5330 5860 6600 8010 8010 NA 4-pole FAD N 650 865 1020 1375 1390 2010 3160 3980 5030 5770 7720 8170 9820 10300 11110 11810 12850 13680 13680 17940 6-pole FAD N 745 980 1095 1620 1640 2210 3590 4490 5820 6660 8930 9580 11760 12330 13720 14718 15800 16610 17180 22090 8-pole FAD N 815 1070 1185 1825 1840 2460 3950 4890 6370 7280 9690 10380 12740 13310 14980 15970 17500 18480 18480 23600
71 80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450 L_
1)
FAZ N 200 290 280 355 350 705 1180 1100 1590 1650 1380 1780 1270 940 2890 2360 1630 730 730 NA
FAZ N 320 430 375 675 665 980 1650 1630 2340 2500 2410 2760 3350 2870 5820 5130 4080 3650 3650 910
FAZ N 390 550 550 925 915 1315 2090 2130 2890 3100 3047 3340 3810 3240 6270 5280 4190 3840 3270 150
FAZ N 455 645 660 1125 1110 1505 2430 2550 3430 3700 3780 4150 4780 4210 7530 6540 5000 4530 4530 1430
On request
124 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Aluminum motors Permissible radial forces according to L10 principle Motors sizes 71 to 132
Motor size No. of poles Length of shaft extention E (mm) 71 80 90 100 112 M 2-8 2-8 2-8 2-8 2 4 6 8 2 4 6 8 2 2 2 4 4 4 6 6 6 6 8 8 8 30 40 50 60 60 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 Ball bearings Basic design with deep groove ball bearings 25,000 hours FXmax (N) FX0 (N) 680 930 1010 2280 1800 1790 1910 1940 1820 1770 1880 1930 3020 3020 3030 3120 3080 3050 3280 3240 3200 3010 3370 3310 3280 570 750 810 1800 1420 1410 1510 1530 1470 1430 1520 1560 2360 2360 2430 2440 2410 2440 2560 2530 2500 2510 2630 2590 2630 40,000 hours FX0 (N) FXmax (N) 680 930 1010 2280 1620 1590 1700 1720 1640 1560 1650 1690 2740 2730 2750 2790 2750 2710 2910 2880 2840 2660 2980 2940 2910 570 750 810 1800 1280 1250 1340 1360 1330 1260 1340 1370 2140 2130 2200 2180 2150 2170 2270 2250 2220 2220 2330 2300 2330
Alternative design with 63-series bearings 25,000 hours 40,000 hours FX0 (N) FXmax (N) FX0 (N) FXmax (N)
112 MB
132 SA 132 SB 132 SC 132 S 132 M 132 MB 132 S 132 MA 132 MB 132 MC 132 S 132 M 132 MB
2160 2160 2160 2160 2100 2100 2100 1700 4070 4060 3990 4090 4100 3990 4100 4100 4100 3840 4100 4100 3990
1700 1700 1700 1700 1700 1700 1700 2100 3180 3170 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200
2160 2160 2160 2160 2100 2100 2100 1700 3670 3670 3690 3830 3780 3740 3990 3970 3930 3700 4100 4060 3990
1700 1700 1700 1700 1700 1700 1700 2100 2870 2870 2960 2990 2950 3000 3120 3100 3070 3090 3200 3170 3200
40,000 hours FX0(N) 4100 4380 4360 5320 5280 1) 4020 5280 5880 6760 2) 7180 7600 8940 7360 3) 7200 9360 10340 9080 4) 9380 10700 12540 5680 6640 7360 7460
FXmax(N) 3320 3545 3540 4300 4305 1) 3300 4380 4800 5640 2) 5980 6340 7400 6200 3) 5820 7560 8360 7360 4) 7600 8680 10160 4600 5380 5960 6060
180
200
225
250
280
1) 2) 3) 4)
The maximum lifetime of the grease is 38,000 h The maximum lifetime of the grease is 27,000 h The maximum lifetime of the grease is 23,000 h The maximum lifetime of the grease is 16,000 h
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 125
Permissible axial forces according to L10 principle The following tables give the permissible axial forces in Newton, assuming zero radial force. The values are based on normal conditions at 50 Hz with standard bearings and calculated bearing lives of 20,000 and 40,000 hours. At 60 Hz the values are to be reduced by 10 %. For two-speed motors, the values are to be based on the higher speed. The permissible loads of simultaneous radial and axial forces will be supplied on request. Given axial forces FAD, assumes D-bearing locked by means of locking ring. Without locking ring the FAD forces should be reduced to 70 % of list value.
FAD
Aluminum motors, motor sizes 71 to 280 Mounting arrangement IM B3
Motor size 20,000 hours 2-pole FAZ FAD N N 625 325 810 470 885 1620 1615 1770 1760 1760 2220 2220 2210 4160 5480 5000 5000 6000 4) 5260 485 1120 1115 1170 1160 1160 1620 1620 1610 4160 5480 6880 7380 9020 4) 5260 4-pole FAD N 780 1015 1170 2065 2060 2245 2245 2235 2840 2830 4740 4360 5000 5000 6000 6500 6-pole FAD N 890 1170 1270 2390 2385 2595 2580 2600 4840 5980 5000 5000 6000 7500 8-pole FAD N 985 1300 1410 2660 2655 2655 2875 2885 5980 6000 5000 5000 6000 7740
FAZ
71 80 90 100 112 M 112 MB 132 M 132 MA 132 MC 132 MBA 132 S 132 SA 132 SB 132 SBB 132 SC 132 SMA 132 SMB 132 SMC 132 SMD 132 SME 160 180 200 225 250 280
1) 2) 3) 4)
FAZ N 480 675 650 1565 1560 1645 1645 1635 2240 2200 4740 4360 7660 7600 9800 6500
FAZ N 590 830 870 1890 1885 1995 1980 2000 4840 5980 8300 10140 11520 7500
FAZ N 685 960 1010 2160 2155 2155 2270 2285 5980 6620 9880 11420 13700 7740
40,000 hours 2-pole FAD FAZ N N 515 215 650 315 720 1280 1275 1400 1395 1395 1740 1740 1730 3425 4600 1) 5000 2) 5000 3) 6000 4) 4220 320 780 775 800 795 795 1140 1140 1130 3425 4600 1) 5700 2) 6120 3) 7500 4) 4220
M000022
4-pole FAD N 630 810 945 1615 1610 1760 1760 1750 2205 2230 3920 3540 5000 5000 6000 5160
FAZ N 330 470 425 1115 1110 1160 1160 1150 1605 1595 3920 3540 6340 6220 8040 5160
6-pole FAD N 710 925 1005 1860 1860 2025 2010 2030 4000 4940 5000 5000 6000 6040
FAZ N 410 595 605 1360 1360 1425 1410 1435 4000 4940 6880 8420 9520 6040
8-pole FAD N 780 1015 1110 2065 2060 2060 2240 2245 4920 5460 5000 5000 6000 6180
FAZ N 480 675 710 1565 1560 1560 1640 1645 4920 5460 8160 9460 11380 6180
The maximum lifetime of the grease is 38,000 h The maximum lifetime of the grease is 27,000 h The maximum lifetime of the grease is 23,000 h The maximum lifetime of the grease is 16,000 h
126 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
FAZ
M000023
FAD
Aluminum motors, motor sizes 71 to 280 Mounting arrangement IM V1
Motor size 20,000 hours 2-pole FAZ FAD N N 640 315 845 450 945 450 1710 1060 1725 1040 1910 1075 1950 1050 1945 1045 2435 1480 2445 1470 2490 1425 4560 3810 5920 5115 5000 6350 5000 6770 6000 4) 8335 4) 6400 4400 4-pole FAD N 800 1075 1245 2180 2210 2460 2460 2495 3150 3195 5260 5080 5000 5000 6000 7920 6-pole FAD N 925 1225 1360 2510 2540 2815 2885 2780 5400 6000 5000 5000 6000 8500 8-pole FAD N 1020 1350 1485 2780 2790 2810 3130 3100 6560 6000 5000 5000 6000 8500
71 80 90 100 112 M 112 MB 132 M 132 MA 132 MC 132 MBA 132 S 132 SA 132 SB 132 SBB 132 SC 132 SMA 132 SMB 132 SMC 132 SMD 132 SME 160 180 200 225 250 280
1) 2) 3) 4)
FAZ N 470 640 600 1485 1460 1505 1505 1465 2035 1995 4310 3860 6950 6795 8820 5400
FAZ N 570 795 815 1815 1785 1850 1780 1885 4420 5445 7505 9270 10275 6180
FAZ N 665 925 960 2080 2070 2055 2115 2145 5580 6120 9215 10595 12645 6435
40,000 hours 2-pole FAD FAZ N N 530 200 690 290 775 280 1370 715 1385 700 1540 705 1580 670 1575 670 1950 995 1960 985 2005 940 3860 3110 5060 1) 4255 1) 5000 2) 5230 2) 5000 3) 5490 3) 6000 4) 6755 4) 5420 3420
4-pole FAD N 650 865 1020 1735 1110 1970 1970 2010 2515 2560 4440 4240 5000 5000 6000 6640
FAZ N 320 430 375 1035 1010 1015 1015 980 1400 1355 3490 3020 5650 5475 7120 4120
6-pole FAD N 745 980 1095 1980 2010 2245 2315 2210 4540 5600 5000 5000 6000 7840
FAZ N 390 550 550 1285 1260 1280 1210 1315 3560 4385 6025 7490 8235 4640
8-pole FAD N 815 1070 1185 2185 2195 2210 2490 2460 5460 6000 5000 5000 6000 7980
FAZ N 455 645 660 1485 1475 1460 1470 1505 4480 4900 7435 8535 10205 4775
The maximum lifetime of the grease is 38,000 h. The maximum lifetime of the grease is 27,000 h. The maximum lifetime of the grease is 23,000 h. The maximum lifetime of the grease is 16,000 h.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 127
Rating plates
The rating plates are in table form giving values for speed, current and power factor for cast iron motors: 400V-415V690V as standard. For aluminum motors there are one or two voltages in use; 230V-400V depending on the frame size. Other voltage and frequency combinations are possible and can be ordered with variant codes 002 or 209. Please see Variant code section. Cast iron motors, sizes 160 to 450 The following information will be shown on the motor rating plate: Lowest nominal efficiency at 100 %, 75 % and 50 % rated load Efficiency level Year of manufacture Type of protection Apparatus group Temperature class Identification number of the certification body Certificate number : for cast iron motors both ATEX and IECEx are stamped on the rating plate as standard. For aluminum motors self certification. Cast iron motors, sizes 71 to 132
M000741a
M000705
128 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000752a
M000751a
M000742a
5 6 7 8 9 10 11 12 13 14
E Voltage and frequency code F Generation code G Variant codes
Position 14
Position 8 to 10 Serial number Generation code G, H... The product code must be, if needed, followed by variant codes. Position 11 - (dash)
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 129
IE2
Current IN Is
Torque TN Tl TN 2.2 2.4 4.2 2.7 2.5 1.9 3.1 2.9 2.0 2.0 2.6 3.0 2.8 2.5 3.0 2.8 2.7 2.4 2.1 2.1 2.0 2.2 2.3 2.6 2.1 2.1 2.2 2.3 2.2 2.0 2.2 2.1 2.1 2.2 2.2 2.6 2.6 2.7 2.3 2.9 2.9 2.6 2.8 2.6 2.6 2.4 Tb TN 2.3 2.5 4.2 3.5 2.6 2.5 3.5 3.2 2.7 3.6 3.1 3.5 3.4 3.1 3.2 3.2 3.0 3.1 3.0 2.9 3.0 3.0 3.0 3.0 3.3 3.0 3.0 2.9 2.9 3.9 4.1 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.1 3.6 3.1 3.0 3.2 3.2 3.1 3.0 Moment of inertia J = 1/4 GD2 Weight kgm2 kg 0.00039 0.00051 0.001 0.0012 0.00254 0.0028 0.00528 0.00575 0.01275 0.01359 0.043 0.052 0.062 0.089 0.15 0.19 0.26 0.49 0.8 0.9 1.2 1.4 1.7 2.1 3 3.4 3.6 4.1 4.3 4.8 5.2 7.9 7.9 8.2 8.2 9.3 9.3 0.07 0.13 0.13 0.22 0.29 0.31 0.57 0.59 1.15
Is / IN
Product code 400 V 50 Hz 3GGP 071 321-B 3GGP 071 322-B 3GGP 081 322-B 3GGP 081 323-B 3GGP 091 322-B 3GGP 091 323-B 3GGP 101 322-B 3GGP 111 322-B 3GGP 131 322-B 3GGP 131 324-B 3GGP 161 410-H 3GGP 161 420-H 3GGP 161 430-H 3GGP 181 410-H 3GGP 201 410-G 3GGP 201 430-G 3GGP 221 220-G 3GGP 251 210-G 3GGP 281 210-G 3GGP 281 220-G 3GGP 311 210-G 3GGP 311 220-G 3GGP 311 230-G 3GGP 311 410-G 3GGP 351 210-G 3GGP 351 220-G 3GGP 351 230-G 3GGP 351 410-G 3GGP 351 420-G 3GGP 351 810-G 3GGP 351 820-G 3GGP 401 510-G 3GGP 401 810-G 3GGP 401 520-G 3GGP 401 820-G 3GGP 401 530-G 3GGP 401 830-G 400 V 50 Hz 3GGP 161 440-H 3GGP 181 420-H 3GGP 181 430-H 3GGP 201 450-G 3GGP 221 230-G 3GGP 221 240-G 3GGP 251 220-G 3GGP 251 230-G 3GGP 281 230-G
Full 3/4 Speed load load r/min 100% 75% 2768 2813 2895 2870 2900 2885 2925 2895 2865 2890 2931 2929 2934 2938 2956 2954 2968 2975 2978 2976 2982 2982 2981 2980 2984 2980 2984 2982 2983 2982 2983 2988 2988 2987 2987 2987 2987 2929 2943 2947 2944 2965 2966 2969 2965 2978 74.8 77.8 80.6 81.8 82.2 84.7 85.2 86.1 88.0 88.6 90.1 91.2 91.8 91.7 93.2 93.6 93.9 94.3 94.3 94.6 94.9 95.1 95.4 95.7 95.7 95.7 95.7 96.9 97.1 96.9 97.0 97.2 97.2 97.4 97.4 97.5 97.5 91.2 92.5 92.8 93.3 93.9 93.9 94.0 94.0 95.1 74.7 78.3 79.9 82.4 84.1 86.7 84.9 87.0 88.6 88.8 90.5 91.9 92.2 92.2 93.6 94.0 93.8 94.1 94.1 94.5 94.4 94.8 95.2 95.7 95.5 95.7 95.7 96.6 97.0 96.9 97.0 97.2 97.2 97.4 97.4 97.4 97.4 91.6 93.0 93.0 93.6 93.9 93.7 94.0 94.2 95.0
Power 1/2 load factor 50% cos 71.0 76.0 76.2 80.2 82.7 85.7 82.8 86.6 88.0 87.5 89.6 91.4 91.8 91.7 93.0 93.4 92.9 93.0 92.8 93.5 92.9 93.6 94.2 94.9 94.5 95.1 95.2 95.9 96.4 96.5 96.5 96.6 96.6 96.9 96.9 97.0 97.0 91.0 92.6 92.5 93.0 92.9 92.6 93.2 93.7 94.2 0.78 0.79 0.74 0.80 0.86 0.87 0.86 0.86 0.86 0.84 0.89 0.89 0.90 0.90 0.88 0.89 0.87 0.89 0.88 0.90 0.86 0.88 0.89 0.90 0.89 0.89 0.88 0.88 0.90 0.90 0.90 0.89 0.89 0.89 0.89 0.89 0.89 0.90 0.90 0.90 0.88 0.88 0.86 0.89 0.90 0.90
A IN Nm CENELEC-design 0.91 4.5 1.27 1.29 5.6 1.86 1.81 7.7 2.4 2.4 7.5 3.6 3 7.5 4.9 4.3 6.8 7.2 5.9 9.1 9.7 7.7 8.1 13.1 10.4 7.0 18.3 14.5 7.3 24.7 19.7 7.2 35.8 26.6 7.2 48.9 32.3 7.5 60.2 38.4 7.0 71.5 52.7 7.4 96.9 64.1 7.5 119 79.5 7.2 144 94.5 7.8 176 130 7.6 240 152 7.4 288 194 7.6 352 227 7.4 422 271 7.5 512 335 7.7 640 423 7.7 800 533 7.0 1009 608 7.2 1136 677 7.1 1280 743 7.9 1440 827 7.5 1601 925 8.0 1792 934 7.8 1789 934 7.8 1789 1048 7.8 2014 1048 7.8 2014 1180 7.8 2269 1180 7.8 2269 High-output design 38.6 7.3 71.7 52 6.8 97.3 63.9 7.9 119 79.1 7.3 145 96 7.1 177 119 7.4 215 129 7.9 241 153 7.7 289 185 7.9 352
11 11 16 18 24 25 36 37 68 70 207 216 227 259 275 305 365 425 625 665 880 940 1025 1190 1600 1680 1750 2000 2080 2320 2460 2950 2950 3050 3050 3300 3300 233 292 292 310 385 395 465 475 725
Temperature rise class IF Efciency class IE1 3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045 Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045 For 400-415 V 50 Hz (380 V 50 Hz voltage code B)
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
4)
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
5)
130 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
IE2
Current IN Is
Torque TN Tl TN 1.9 1.6 2.0 2.7 2.7 2.7 2.9 2.9 2.5 1.7 1.6 3.0 3.0 2.6 2.5 3.0 3.2 3.2 2.5 2.5 2.5 2.0 2.3 2.4 2.5 2.3 2.3 2.4 2.3 2.3 2.0 2.4 2.4 2.2 2.2 2.5 2.5 1.3 1.3 1.3 3.2 3.3 2.8 3.5 3.4 3.6 2.8 2.9 3.0 Tb TN 2.0 2.1 2.8 3.2 3.4 3.4 3.6 3.4 2.9 2.4 2.4 3.5 3.4 3.1 3.0 2.8 2.9 2.7 3.1 2.8 2.7 2.5 2.7 2.9 2.9 2.7 2.8 2.7 2.6 2.9 3.0 2.8 2.8 2.9 2.9 3.1 3.1 2.8 2.8 2.7 3.5 3.6 3.2 3.2 2.9 3.0 3.2 3.5 3.0 Moment of inertia J = 1/4 GD2 Weight kgm2 kg 0.00074 0.00088 0.00144 0.00205 0.0044 0.0053 0.00948 0.011 0.0125 0.03282 0.03659 0.096 0.13 0.19 0.21 0.34 0.42 0.49 0.72 1.25 1.5 2.3 2.6 2.9 3.5 5.9 6.9 7.2 8.4 8.4 10 15 15 16 16 17 17 23 25 30 0.13 0.13 0.248 0.34 0.55 0.55 0.88 0.98 1.85
Is / IN
Product code 400 V 50 Hz 3GGP 072 321-B 3GGP 072 322-B 3GGP 082 321-B 3GGP 082 324-B 3GGP 092 322-B 3GGP 092 325-B 3GGP 102 323-B 3GGP 102 324-B 3GGP 112 322-B 3GGP 132 322-B 3GGP 132 323-B 3GGP 162 430-H 3GGP 162 450-H 3GGP 182 410-H 3GGP 182 420-H 3GGP 202 420-G 3GGP 222 220-G 3GGP 222 230-G 3GGP 252 210-G 3GGP 282 210-G 3GGP 282 220-G 3GGP 312 210-G 3GGP 312 220-G 3GGP 312 230-G 3GGP 312 410-G 3GGP 352 210-G 3GGP 352 220-G 3GGP 352 230-G 3GGP 352 410-G 3GGP 352 420-G 3GGP 352 810-G 3GGP 402 510-G 3GGP 402 810-G 3GGP 402 520-G 3GGP 402 820-G 3GGP 402 530-G 3GGP 402 830-G 3GGP 452 510-G 3GGP 452 520-G 3GGP 452 530-G 400 V 50 Hz 3GGP 162 460-H 3GGP 162 470-H 3GGP 182 430-H 3GGP 202 430-G 3GGP 222 240-G 3GGP 222 250-G 3GGP 252 220-G 3GGP 252 230-G 3GGP 282 230-G
Full 3/4 Speed load load r/min 100% 75% 1365 1380 1415 1430 1435 1430 1450 1450 1440 1460 1450 1470 1467 1474 1471 1475 1480 1477 1479 1484 1483 1487 1487 1487 1486 1488 1488 1487 1489 1490 1490 1491 1491 1491 1491 1492 1492 1492 1492 1491 1469 1466 1473 1475 1483 1479 1476 1477 1485 68.3 72.4 74.5 81.0 83.6 84.3 85.9 86.8 86.8 89.0 89.3 91.2 92.0 91.6 91.6 93.6 93.6 94.1 94.3 94.5 94.7 95.1 95.4 95.6 95.6 95.9 95.9 95.9 96.3 96.8 97.0 96.8 96.8 97.0 97.0 97.1 97.1 96.9 97.1 97.2 91.7 90.8 92.2 93.0 94.3 93.6 94.3 94.1 95.1 70.8 74.5 73.8 80.7 84.5 85.6 85.1 87.0 87.7 89.8 90.1 91.5 92.4 92.0 92.4 94.0 93.9 94.6 94.3 94.5 94.8 95.1 95.4 95.6 95.6 95.9 95.9 95.9 96.3 96.8 97.0 96.8 96.8 97.0 97.0 97.1 97.1 96.9 97.1 97.2 92.1 91.1 92.3 93.1 94.5 93.7 94.5 94.4 95.2
Power 1/2 load factor 50% cos 69.7 74.6 70.0 77.3 83.2 84.7 83.4 85.4 87.3 88.9 90.0 90.6 92.1 91.2 92.2 93.7 93.4 94.4 93.6 93.9 94.4 94.3 94.7 95.1 95.3 95.5 95.6 95.7 95.9 96.3 96.5 96.3 96.3 96.5 96.5 96.6 96.6 96.2 96.5 96.7 91.4 90.4 91.6 92.3 93.9 92.9 94.2 94.0 94.7 0.81 0.83 0.73 0.73 0.80 0.83 0.78 0.79 0.81 0.80 0.81 0.82 0.84 0.83 0.83 0.85 0.85 0.88 0.84 0.85 0.86 0.86 0.86 0.85 0.86 0.86 0.86 0.86 0.85 0.86 0.86 0.85 0.85 0.87 0.87 0.85 0.85 0.86 0.86 0.86 0.83 0.81 0.81 0.82 0.83 0.84 0.86 0.85 0.86
A IN Nm CENELEC-design 0.65 3.5 1.74 0.88 4.0 2.5 1.45 5.0 3.7 1.83 5.3 5 2.3 6.1 7.3 3 6.3 10 4.7 6.4 14.4 6.3 7.7 19.7 8.2 7.0 26.5 11.1 5.9 35.9 14.9 5.6 49.3 21.2 7.8 71.4 28 7.8 97.6 35.1 7.2 119 41.7 6.8 142 54.4 7.4 194 67.1 7.6 238 78.4 7.6 290 100 7.2 355 134 6.9 482 159 7.2 579 194 7.2 706 232 7.1 847 284 7.2 1027 351 7.2 1285 437 7.1 1604 551 7.3 2021 612 6.9 2247 705 6.8 2565 780 6.9 2884 865 6.8 3204 982 7.4 3586 982 7.4 3586 1077 7.6 4034 1077 7.6 4034 1189 7.9 4352 1189 7.9 4352 1385 7.0 5120 1555 7.0 5760 1726 6.8 6404 High-output design 35 7.8 120 43.1 7.9 143 57.9 7.1 194 70 7.5 239 101 7.4 354 110 8.0 387 133 7.6 485 155 7.8 556 194 7.6 707
10 11 15 17 25 27 36 38 44 70 73 226 249 271 279 305 355 390 415 625 665 900 960 1000 1160 1610 1780 1820 2140 2140 2500 3200 3200 3300 3300 3400 3400 4050 4350 4700 249 249 298 305 410 410 470 495 725
Temperature rise class F Efciency class IE1 For 400-415 V 50 Hz (380 V 50 Hz voltage code B)
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 131
IE2
Current IN Is
Torque TN Tl TN 2.0 2.2 1.8 1.8 2.3 1.9 1.5 1.7 1.8 1.5 2.0 1.9 2.3 1.9 3.2 3.2 3.4 3.2 2.5 2.7 2.4 2.4 2.5 2.7 2.0 2.2 2.6 2.5 2.3 2.3 2.3 2.4 2.4 2.5 2.5 2.4 2.4 1.1 1.3 1.3 2.8 2.0 3.5 3.0 3.3 2.8 Tb TN 2.1 2.3 2.2 2.2 3.1 2.3 1.1 2.3 2.9 2.2 2.3 3.0 3.5 3.2 3.1 3.2 3.0 2.9 2.5 2.6 2.8 2.8 2.9 3.0 2.6 2.7 2.9 2.7 2.7 2.7 2.7 2.8 2.8 2.7 2.7 2.8 2.8 2.5 2.5 2.7 3.9 3.2 3.4 2.8 2.8 2.7 Moment of inertia J = 1/4 GD2 Weight kgm2 kg 0.00089 0.0011 0.00187 0.00239 0.00491 0.0054 0.00873 0.0125 0.03336 0.03336 0.0487 0.088 0.126 0.25 0.37 0.43 0.64 1.16 1.85 2.2 3.2 4.1 4.9 5.8 7.9 9.7 11.3 13.5 15.5 17 17 20.5 20.5 22 22 24 24 31 37 41 0.126 0.25 0.49 0.75 1.49 2.85
Is / IN
Product code 400 V 50 Hz 3GGP 073 321-B 3GGP 073 322-B 3GGP 083 321-B 3GGP 083 322-B 3GGP 093 323-B 3GGP 093 324-B 3GGP 103 322-B 3GGP 113 322-B 3GGP 133 321-B 3GGP 133 322-B 3GGP 133 324-B 3GGP 163 410-H 3GGP 163 420-H 3GGP 183 420-H 3GGP 203 410-G 3GGP 203 420-G 3GGP 223 220-G 3GGP 253 210-G 3GGP 283 210-G 3GGP 283 220-G 3GGP 313 210-G 3GGP 313 220-G 3GGP 313 230-G 3GGP 313 410-G 3GGP 353 210-G 3GGP 353 220-G 3GGP 353 230-G 3GGP 353 420-G 3GGP 353 810-G 3GGP 403 510-G 3GGP 403 810-G 3GGP 403 520-G 3GGP 403 820-G 3GGP 403 530-G 3GGP 403 830-G 3GGP 403 540-G 3GGP 403 840-G 3GGP 453 510-G 3GGP 453 520-G 3GGP 453 530-G 400 V 50 Hz 3GGP 163 430-H 3GGP 183 430-H 3GGP 203 430-G 3GGP 223 230-G 3GGP 253 220-G 3GGP 283 230-G
Full 3/4 Speed load load r/min 100% 75% 900 895 915 920 960 930 950 950 975 960 965 965 972 972 983 983 985 987 990 990 992 992 991 991 993 993 993 992 993 993 993 994 994 993 993 993 993 994 995 995 969 975 983 983 986 990 63.7 67.2 71.0 73.9 78.7 78.2 82.2 82.5 85.3 84.9 86.1 87.2 90.1 90.4 90.9 91.6 92.2 93.1 93.4 93.8 94.4 94.8 95.0 95.3 95.4 95.7 95.7 95.7 95.7 96.2 96.2 96.6 96.6 96.6 96.6 96.9 96.9 96.7 96.9 96.9 89.2 90.1 90.8 92.1 93.1 94.2 63.8 67.2 71.1 75.0 77.3 78.6 82.9 83.8 84.5 85.3 86.6 88.4 90.8 91.0 91.1 91.9 92.6 93.4 93.6 94.0 94.4 94.8 95.0 95.4 95.4 95.7 95.7 95.7 95.7 96.3 96.3 96.6 96.6 96.7 96.7 96.9 96.9 96.8 96.9 97.0 89.4 90.2 91.2 92.5 93.3 94.5
Power 1/2 load factor 50% cos 59.0 62.6 67.0 72.8 72.5 76.4 81.6 81.7 81.3 83.9 85.5 88.2 90.4 90.4 90.3 91.0 92.2 92.8 93.1 93.3 93.5 94.2 94.6 94.9 94.8 95.1 95.1 95.2 95.1 95.8 95.8 96.1 96.1 96.2 96.2 96.4 96.4 96.4 96.5 96.6 88.0 88.7 90.2 92.1 92.6 94.1 0.71 0.69 0.69 0.71 0.58 0.66 0.69 0.69 0.63 0.68 0.71 0.81 0.81 0.82 0.82 0.82 0.82 0.81 0.84 0.84 0.82 0.84 0.83 0.83 0.83 0.84 0.83 0.83 0.83 0.82 0.82 0.82 0.82 0.83 0.83 0.85 0.85 0.84 0.85 0.84 0.75 0.74 0.81 0.83 0.82 0.84
A IN Nm CENELEC-design 0.57 3.1 1.9 0.77 3.4 2.6 1.09 3.6 3.8 1.51 3.8 5.7 2.3 4.5 7.4 3 4.0 11.2 3.8 4.0 15 5.5 4.4 22.1 8 5.5 29.3 10 4.6 39.7 12.9 5.1 54.4 15.3 6.5 74.2 21.7 7.8 108 29.2 7.2 147 35.8 7.1 179 42.2 7.5 213 57.2 7.4 290 70.8 7.2 357 82.7 7.0 434 100 7.0 530 139 7.4 721 163 7.5 866 201 7.4 1059 240 7.5 1271 291 7.0 1538 359 7.2 1923 454 7.4 2404 572 7.0 3032 645 6.8 3413 731 7.1 3846 731 7.1 3846 819 7.4 4323 819 7.4 4323 900 7.2 4808 900 7.2 4808 981 7.4 5385 981 7.4 5385 1119 6.5 6052 1244 7.0 6814 1418 7.2 7677 High-output design 30.2 7.9 137 40 7.2 181 58.8 7.5 291 69.8 7.1 359 85 7.2 435 136 7.3 723
10 12 15 17 25 28 37 44 69 69 86 220 247 298 265 285 350 420 605 645 830 930 1000 1150 1520 1680 1820 2180 2500 2900 2900 3150 3150 3300 3300 3400 3400 4150 4500 4800 247 298 305 380 465 725
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
132 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Current IN Is
Torque TN Tl TN 1.8 2.8 2.2 2.0 1.4 1.3 1.8 1.7 1.4 1.1 1.2 1.7 1.9 2.1 1.7 2.4 2.2 2.2 2.0 1.7 1.8 1.6 1.7 1.8 1.8 1.5 1.6 1.6 1.6 1.2 1.2 1.2 1.2 1.3 1.3 1.0 1.0 1.2 1.3 2.2 2.3 2.3 1.9 Tb TN 2.0 2.4 2.5 1.9 2.2 1.5 2.5 2.2 1.9 1.7 1.8 2.8 3.1 3.1 2.7 3.2 3.0 2.9 2.9 3.0 3.1 2.7 2.7 2.7 2.7 2.6 2.6 2.6 2.7 2.6 2.6 2.5 2.5 2.7 2.7 2.5 2.6 2.9 3.2 3.2 3.0 3.4 3.1 Moment of inertia J = 1/4 GD2 Weight kgm2 kg 0.00089 0.0011 0.00187 0.00239 0.00444 0.00491 0.0072 0.00871 0.0106 0.03336 0.04003 0.133 0.133 0.133 0.245 0.45 0.61 0.68 1.25 1.85 2.2 3.2 4.1 4.9 5.8 7.9 9.7 11.3 13.5 17 17 21 21 24 24 26 29 35 41 0.54 0.75 1.52 2.85
Is / IN
Motor type = 8-poles M3GP 71 MA M3GP 71 MB M3GP 80 MA M3GP 80 MB M3GP 90 SLB M3GP 90 SLC M3GP 100 LA M3GP 100 LB M3GP 112 M M3GP 132 SMA M3GP 132 SMB M3GP 160 MLA M3GP 160 MLB M3GP 160 MLC M3GP 180 MLB M3GP 200 MLA M3GP 225 SMA M3GP 225 SMB M3GP 250 SMA M3GP 280 SMA M3GP 280 SMB M3GP 315 SMA M3GP 315 SMB M3GP 315 SMC M3GP 315 MLA M3GP 355 SMA M3GP 355 SMB M3GP 355 SMC M3GP 355 MLB M3GP 400 LA M3GP 400 LKA M3GP 400 LB M3GP 400 LKB M3GP 400 LC M3GP 400 LKC M3GP 450 LA M3GP 450 LB M3GP 450 LC M3GP 450 LD = 8-poles M3GP 200 MLB M3GP 225 SMC M3GP 250 SMB M3GP 280 SMC
Product code 400 V 50 Hz 3GGP 074 101-B 3GGP 074 102-B 3GGP 084 101-B 3GGP 084 102-B 3GGP 094 102-B 3GGP 094 103-B 3GGP 104 101-B 3GGP 104 102-B 3GGP 114 101-B 3GGP 134 101-B 3GGP 134 102-B 3GGP 164 410-H 3GGP 164 420-H 3GGP 164 430-H 3GGP 184 420-H 3GGP 204 410-G 3GGP 224 210-G 3GGP 224 220-G 3GGP 254 210-G 3GGP 284 210-G 3GGP 284 220-G 3GGP 314 210-G 3GGP 314 220-G 3GGP 314 230-G 3GGP 314 410-G 3GGP 354 210-G 3GGP 354 220-G 3GGP 354 230-G 3GGP 354 420-G 3GGP 404 510-G 3GGP 404 810-G 3GGP 404 520-G 3GGP 404 820-G 3GGP 404 530-G 3GGP 404 830-G 3GGP 454 510-G 3GGP 454 520-G 3GGP 454 530-G 3GGP 454 540-G 400 V 50 Hz 3GGP 204 420-G 3GGP 224 230-G 3GGP 254 220-G 3GGP 284 230-G
Full 3/4 Speed load load r/min 100% 75% 660 670 700 680 705 655 710 695 690 715 715 722 723 718 723 734 734 732 735 741 741 742 741 741 740 744 744 743 743 744 744 743 743 744 744 744 744 744 745 734 731 737 741 49.4 51.4 54.2 58.6 66.3 61.8 74.0 76.0 74.4 79.7 79.9 86.7 86.8 85.5 88.3 89.9 90.0 90.6 91.4 92.7 93.2 93.4 93.7 94.0 94.0 94.7 95.2 95.3 95.4 96.1 96.1 96.2 96.2 96.3 96.3 96.2 96.3 96.4 96.6 89.8 90.7 92.2 93.4 46.0 47.5 51.1 58.1 64.0 65.6 73.0 76.5 75.9 80.8 80.8 87.4 87.6 86.3 89.2 90.3 90.3 91.2 91.2 92.7 93.2 93.5 93.9 94.2 94.3 94.7 95.2 95.4 95.5 96.2 96.2 96.3 96.3 96.4 96.4 96.4 96.4 96.5 96.6 90.2 91.5 91.7 93.5
Power 1/2 load factor 50% cos 38.5 39.9 43.5 52.3 57.1 65.2 68.2 74.6 74.1 78.7 79.1 86.6 86.8 85.5 88.7 89.6 89.3 90.6 90.7 91.6 92.2 92.7 93.4 93.6 94.0 94.0 94.5 94.8 95.0 95.8 95.8 96.1 96.1 96.0 96.0 96.2 96.2 96.1 96.2 89.6 91.3 91.0 92.8 0.59 0.56 0.59 0.65 0.54 0.67 0.61 0.66 0.70 0.66 0.64 0.71 0.71 0.70 0.72 0.79 0.74 0.77 0.78 0.78 0.78 0.81 0.82 0.82 0.83 0.80 0.80 0.80 0.80 0.81 0.81 0.83 0.83 0.82 0.82 0.83 0.83 0.82 0.81 0.80 0.78 0.78 0.80
A IN Nm CENELEC-design 0.44 2.0 1.3 0.6 2.1 1.71 0.81 3.6 2.4 0.94 3.0 3.5 1.49 2.8 5 1.91 2.3 8 2.3 3.6 10 3.1 3.4 15.1 4.1 3.2 20.7 6 3.2 29.3 8.4 4.7 40 9.3 5.4 52.9 12.8 5.8 72.6 18 5.7 99.7 24.9 5.7 145 30.4 7.0 195 40 6.1 240 45.5 6.5 287 60.7 6.7 389 73.8 7.3 476 89.3 7.6 579 104 7.1 707 140 7.1 966 168 7.4 1159 203 7.3 1419 251 7.5 1694 303 7.6 2053 378 7.4 2570 472 7.5 3213 584 7.0 4043 584 7.0 4043 641 6.8 4562 641 6.8 4562 731 7.4 5134 731 7.4 5134 813 6.0 5775 902 6.4 6417 1022 7.0 7187 1162 7.6 8075 High-output design 37.1 6.9 240 61.2 6.3 391 74.2 7.5 479 106 7.9 708
11 12 15 17 24 25 30 30 39 70 75 245 245 245 292 280 335 350 420 605 645 830 930 1000 1150 1520 1680 1820 2180 2900 2900 3200 3200 3400 3400 3750 4000 4350 4800 300 375 465 725
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 133
IE3
Current
Torque Tl TN 2.9 3.2 3.0 2.6 2.1 2.5 1.9 2.4 2.2 1.9 2.0 2.5 2.2 2.3 2.3 3.2 2.9 3.2 2.7 2.5 2.9 2.4 2.6 2.7 2.5 2.1 2.3 2.5 2.8 2.7 Tb TN 3.3 3.5 3.4 2.7 2.9 3.1 2.6 3.0 2.7 2.6 3.1 2.7 3.0 2.8 2.6 2.9 3.3 3.4 3.4 2.8 3.0 3.1 3.2 3.0 2.9 2.7 3.0 2.9 2.9 2.9 Moment of inertia J = 1/4 GD2 Weight kgm2 kg 0.22 0.22 0.34 0.68 0.9 1.15 1.4 1.7 2.1 2.2 3 2.9 3.4 3.6 4.1 0.37 0.55 0.59 0.98 1.5 1.85 2.9 3.2 3.9 5 5.9 5.5 6.9 7.2 8.4
Is / IN
Product code 400 V 50 Hz 3GGP 201 450-J 3GGP 201 460-J 3GGP 221 250-J 3GGP 251 240-J 3GGP 281 220-K 3GGP 281 230-K 3GGP 311 220-K 3GGP 311 230-K 3GGP 311 410-K 3GGP 311 420-K 3GGP 351 210-K 3GGP 311 820-K 3GGP 351 220-K 3GGP 351 230-K 3GGP 351 410-K 400 V 50 Hz 3GGP 202 450-J 3GGP 222 250-J 3GGP 222 260-J 3GGP 252 230-J 3GGP 282 220-K 3GGP 282 230-K 3GGP 312 230-K 3GGP 312 240-K 3GGP 312 420-K 3GGP 312 820-K 3GGP 352 210-K 3GGP 312 830-K 3GGP 352 220-K 3GGP 352 230-K 3GGP 352 410-K
Full 3/4 Speed load load r/min 100% 75% 2957 2958 2970 2977 2979 2981 2982 2984 2982 2982 2984 2981 2983 2984 2982 1478 1482 1479 1483 1486 1487 1490 1490 1489 1490 1490 1491 1491 1491 1491 94.1 94.6 95.0 95.2 95.5 95.7 95.9 95.9 96.1 96.2 96.2 96.3 96.3 96.4 96.5 94.2 94.6 94.8 95.3 95.7 95.9 96.3 96.4 96.4 96.5 96.5 96.6 96.6 96.7 96.7 94.3 94.8 95.2 95.5 95.4 95.6 95.7 95.9 96.1 96.2 96.1 96.3 96.3 96.4 96.5 94.6 95.0 95.2 95.4 95.8 96.0 96.3 96.4 96.4 96.5 96.5 96.6 96.6 96.7 96.7
1/2 load 50% 93.7 94.3 94.5 95.0 94.6 94.8 95.0 95.3 95.8 96.0 95.5 96.2 95.9 95.9 96.3 94.5 94.8 95.0 95.0 95.3 95.5 95.7 95.9 96.1 96.3 96.3 96.4 96.3 96.3 96.4
Power IN Is TN factor cos A IN Nm CENELEC-design 0.87 52.8 7.7 96.8 0.86 65.6 8.3 119 0.88 77.6 8.0 144 0.91 91.6 8.1 176 0.87 130 7.3 240 0.88 154 8.0 288 0.87 190 6.7 352 0.88 225 7.9 422 0.90 267 7.3 512 0.90 333 6.8 640 0.89 337 7.6 640 0.91 411 7.9 800 0.90 416 7.6 800 0.89 529 7.8 1008 0.90 589 7.5 1136 CENELEC-design 0.86 53.4 7.8 193 0.88 64.1 7.6 238 0.87 78.7 8.0 290 0.86 96.8 7.3 354 0.85 133 7.4 481 0.85 159 7.9 577 0.85 193 7.8 704 0.85 232 7.9 845 0.86 278 7.9 1026 0.87 343 7.6 1281 0.87 343 7.3 1281 0.87 429 7.8 1601 0.87 429 7.8 1601 0.85 553 7.4 2017 0.86 616 7.9 2273
310 310 406 493 665 725 940 1025 1190 1220 1600 1540 1680 1750 2000 316 410 416 495 665 725 1000 1065 1220 1520 1610 1600 1780 1820 2140
3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
134 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
IE3
Power IN Is TN factor cos A IN Nm CENELEC-design 0.84 34.3 8.1 178 0.84 40.6 8.2 213 0.85 54.1 7.9 289 0.84 67.3 8.2 356 0.86 79.6 6.9 433 0.86 97 6.8 530 0.84 135 7.0 721 0.83 163 7.2 864 0.84 197 6.9 1057 0.83 239 6.9 1269 0.83 290 7.4 1537 0.83 290 7.0 1535 0.83 362 7.3 1919 0.83 452 7.1 2399 0.83 570 6.9 3026 0.80 667 7.7 3407
305 314 410 500 680 725 1000 1040 1200 1410 1600 1680 1820 2180 2500 2600
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 135
IE2
Current
Torque Tb TN 2.9 2.75 3.9 3.6 3.32 3.2 4 2.8 3.6 3.2 3.1 3.3 3.4 3.3 3.1 3.3 2.5 2.7 2.8 3.2 3.2 3 3 3.6 3.4 3 3.7 3.4 3.95 4.3 3.8 3.3 3.3 2.5 3.1 Moment Sound of inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00035 0.00045 0.0009 0.0012 0.0024 0.0027 0.005 0.0062 0.016 0.022 0.044 0.053 0.063 0.076 0.178 0.196 0.244 0.507 0.583 0.644 0.00056 0.0011 0.0027 0.005 0.0062 0.018 0.01865 0.018 0.02 0.02559 0.02559 0.092 0.196 0.274 0.583
Is / IN
Product code 400 V 50 Hz 3GAA 071 311-E 3GAA 071 312-E 3GAA 081 312-E 3GAA 081 313-E 3GAA 091 312-E 3GAA 091 313-E 3GAA 101 312-E 3GAA 111 312-E 3GAA 131 312-E 3GAA 131 313-E 3GAA 161 031-G 3GAA 161 036-G 3GAA 161 037-G 3GAA 181 031-G 3GAA 201 035-G 3GAA 201 036-G 3GAA 221 031-G 3GAA 251 031-G 3GAA 281 031-G 3GAA 281 032-G 400 V 50 Hz 3GAA 071 003-E 3GAA 081 003-E 3GAA 091 003-E 3GAA 101 002-E 3GAA 111 102-E 3GAA 131 004-E 3GAA 131 315-E 3GAA 131 003-E 3GAA 131 316-E 3GAA 131 317-E 3GAA 131 008-E 3GAA 181 032-G 3GAA 201 033-G 3GAA 221 032-G 3GAA 251 032-G
Full 3/4 Speed load load r/min 100% 75% 2800 2790 2895 2880 2900 2875 2930 2885 2915 2915 2938 2934 2932 2952 2956 2959 2961 2967 2968 2971 2785 2830 2860 2900 2850 2875 2900 2890 2905 2895 2890 2950 2957 2961 2970 71.6 78.4 80.6 82.1 84.1 84.6 87.9 86.1 88.0 88.5 90.7 91.5 92.0 92.2 93.1 93.4 93.6 94.1 94.5 95.0 76.6 80.7 81.0 84.3 86.4 87.0 90.3 88.7 90.4 91.1 90.2 92.8 93.3 93.9 94.6 72.3 79.8 80.4 82.0 85.0 85.7 87.9 87.0 88.5 88.7 91.5 92.5 93.1 92.7 93.5 93.7 93.9 94.4 94.8 95.2 77.1 82.0 81.2 83.9 87.0 88.0 90.8 89.5 90.7 92.2 91.0 93.5 93.8 94.3 94.9
1/2 load 50% 70.2 78.7 77.3 79.2 83.5 85.5 86.6 88.0 87.6 88.1 91.1 92.2 93.1 92.2 92.9 93.0 93.1 93.8 94.3 94.8 76.4 80.0 79.0 83.7 87.4 86.5 90.4 89.3 89.8 92.4 90.9 93.3 93.2 93.6 94.4
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.76 0.98 5.1 1.26 3.0 0.78 1.29 5.3 1.88 2.9 0.79 1.7 8.1 2.4 3.7 0.81 2.3 7.6 3.6 2.8 0.86 2.9 7.6 4.9 2.5 0.85 4.4 6.9 7.3 2.8 0.86 5.7 8.7 9.7 3.3 0.88 7.6 7.6 13.2 2.5 0.82 11 7.9 18 2.6 0.87 14 7.6 24.5 2.2 0.91 19.2 7.5 35.7 2.4 0.91 26 7.5 48.8 2.5 0.92 31.5 7.5 60.2 2.9 0.87 39.5 7.7 71.1 2.8 0.90 51.6 7.7 96.9 2.7 0.90 63.5 8.2 119 3.0 0.88 78.8 6.7 145 2.5 0.88 95.8 6.8 177 2.2 0.89 128 7.1 241 2.5 0.89 153 7.8 289 2.6 High-output design 0.80 1.76 5.3 2.5 3.2 0.83 3.2 5.8 5 2.6 0.86 5.5 7.0 9 2.6 0.86 7.9 7.5 13.1 2.7 0.90 10.2 7.2 18.4 3.4 0.92 16.5 7.2 30.5 2.5 0.87 20.2 8.5 36.2 2.7 0.89 20.1 8.1 36.3 2.8 0.84 28.5 9.1 49.3 3.3 0.89 32.9 9.7 61 3.2 0.85 41.4 9.7 72.6 3.9 0.88 53 7.9 97.1 2.8 0.88 79.1 8.1 145 3.1 0.88 96 6.5 177 2.4 0.89 128 7.6 241 2.8
4.9 5.9 10.5 11 16 18 25 30 42 56 91 105 123 132 210 225 263 304 389 425 6.5 11 18 25 30 52 77 52 81 93 91 149 225 286 351
58 58 60 60 60 63 62 68 73 73 69 69 69 69 72 72 74 75 75 75 58 60 68 68 68 68 68 68 69 68 69 69 72 74 75
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
136 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
IE2
Current
Torque Tb TN 2.1 2.2 2.2 2.8 3.2 3.5 3.4 3 3.4 2.6 2.6 2.8 3 2.9 3 3 2.9 3.2 2.9 3 3.6 2.4 2.6 2.5 2.4 2.4 2.8 3.1 2.8 3.13 2.9 2.6 3.2 2.9 2.9 3.1 3.5 Moment Sound of inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00066 0.0008 0.0013 0.0016 0.0043 0.0048 0.009 0.011 0.0126 0.038 0.048 0.081 0.099 0.166 0.195 0.309 0.356 0.44 0.765 0.866 0.941 0.0011 0.0023 0.0023 0.0043 0.0048 0.009 0.0126 0.048 0.0433 0.0517 0.05166 0.11 0.125 0.343 0.474 0.866
Is / IN
Product code 400 V 50 Hz 3GAA 072 311-E 3GAA 072 312-E 3GAA 082 311-E 3GAA 082 314-E 3GAA 092 314-E 3GAA 092 315-E 3GAA 102 313-E 3GAA 102 314-E 3GAA 112 312-E 3GAA 132 312-E 3GAA 132 314-E 3GAA 162 031-G 3GAA 162 032-G 3GAA 182 031-G 3GAA 182 032-G 3GAA 202 031-G 3GAA 222 031-G 3GAA 222 032-G 3GAA 252 031-G 3GAA 282 031-G 3GAA 282 032-G 400 V 50 Hz 3GAA 072 003-E 3GAA 082 003-E 3GAA 082 004-E 3GAA 092 003-E 3GAA 092 004-E 3GAA 102 003-E 3GAA 112 102-E 3GAA 132 004-E 3GAA 132 315-E 3GAA 132 316-E 3GAA 132 007-E 3GAA 162 033-G 3GAA 162 034-G 3GAA 202 032-G 3GAA 222 033-G 3GAA 252 032-G
Full 3/4 Speed load load r/min 100% 75% 1365 1355 1375 1415 1435 1435 1450 1445 1445 1465 1460 1466 1470 1477 1475 1480 1479 1480 1480 1478 1480 1375 1395 1395 1390 1390 1420 1420 1455 1460 1455 1445 1469 1463 1479 1478 1481 65.1 69.7 74.1 79.9 83.7 84.2 87.1 85.7 86.7 89.0 89.1 90.4 91.4 91.9 92.4 93.2 93.4 93.9 94.4 94.3 94.9 69.0 76.0 76.7 79.3 80.0 83.2 85.1 89.8 90.4 90.6 89.4 91.4 91.6 93.4 94.0 94.7 66.0 71.9 75.9 80.4 84.1 84.1 86.8 86.1 86.5 89.8 89.9 91.6 92.4 92.9 93.3 94.0 93.9 94.3 95.0 95.0 95.3 69.3 76.9 77.5 78.5 80.9 83.3 85.5 90.5 91.0 91.3 90.0 92.5 93.0 94.4 94.7 95.0
1/2 load 50% 62.7 71.1 75.0 78.6 83.0 81.9 84.8 85.1 85.2 89.1 89.5 91.3 92.2 92.7 93.2 93.7 93.4 93.9 94.7 94.7 95.0 68.5 76.3 77.9 78.7 79.5 81.7 84.5 89.5 90.1 91.1 89.5 92.3 93.2 94.4 94.5 94.8
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.76 0.72 4.0 1.74 2.0 0.79 0.96 3.8 2.6 2.0 0.78 1.37 4.5 3.8 1.9 0.75 1.8 5.8 5 2.6 0.78 2.4 6.6 7.3 2.9 0.76 3.3 7.0 9.9 3.1 0.78 4.6 7.3 14.4 2.8 0.79 6.3 7.0 19.8 2.4 0.75 8.8 7.3 26.4 3.1 0.79 11.2 6.3 35.8 1.9 0.79 15.3 6.4 49 1.8 0.84 20.9 6.8 71.6 2.2 0.83 28.5 7.1 97.4 2.6 0.84 34.5 7.2 119 2.6 0.84 40.9 7.3 142 2.6 0.84 55.3 7.4 193 2.8 0.84 68 7.1 238 2.6 0.85 81.3 7.5 290 2.8 0.85 98.9 7.0 354 2.6 0.85 135 7.1 484 2.8 0.84 153 8.0 548 3.4 High-output design 0.76 1.51 4.2 3.8 2.4 0.80 2.2 5.2 6.5 2.5 0.79 2.6 5.0 7.5 2.5 0.80 4.2 4.5 12.7 2.2 0.83 4.7 4.5 15.1 2.2 0.82 8.4 5.5 26.8 2.5 0.80 11.6 6.0 36.9 2.7 0.84 17.6 7.5 60.3 2.1 0.79 22.2 7.7 71.9 2.1 0.77 31 7.1 98.4 2.4 0.78 38.2 6.7 122 2.3 0.84 34.7 7.6 120 3.0 0.85 40.7 6.9 143 2.5 0.85 67.2 7.1 238 2.6 0.85 99.3 7.4 355 2.9 0.84 123 7.9 438 3.1
5.2 5.9 8.5 12 16 17 25 28 34 48 59 99 118 146 163 218 240 273 314 389 418 6.5 10.5 10.5 16 17 25 34 59 83 92 92 127 140 234 287 350
45 45 50 50 50 50 54 63 64 66 63 62 62 62 62 63 66 66 67 67 67 45 50 50 50 50 60 64 59 65 67 69 62 62 63 66 67
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 137
IE2
Current
Torque Tb TN 2 2.2 2 1.9 2.3 2.3 2 2.2 2.3 2.18 2.8 3.2 2.9 2.8 2.9 2.8 2.9 2.7 2.6 2.8 2.4 2.4 2.2 2.3 2.22 3.6 2.8 2.6 2.7 2.8 Moment Sound of inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00092 0.0012 0.002 0.0026 0.0048 0.0056 0.009 0.01 0.031 0.038 0.049 0.087 0.114 0.192 0.382 0.448 0.663 1.13 1.369 1.5 0.0015 0.0031 0.0048 0.009 0.0126 0.131 0.531 0.821 1.369 1.5
Is / IN
Product code 400 V 50 Hz 3GAA 073 311-E 3GAA 073 312-E 3GAA 083 311-E 3GAA 083 312-E 3GAA 093 313-E 3GAA 093 314-E 3GAA 103 312-E 3GAA 113 312-E 3GAA 133 311-E 3GAA 133 312-E 3GAA 133 314-E 3GAA 163 031-G 3GAA 163 032-G 3GAA 183 031-G 3GAA 203 031-G 3GAA 203 032-G 3GAA 223 031-G 3GAA 253 031-G 3GAA 283 031-G 3GAA 283 032-G 400 V 50 Hz 3GAA 073 003-E 3GAA 083 003-E 3GAA 093 003-E 3GAA 103 002-E 3GAA 113 102-E 3GAA 163 033-G 3GAA 203 033-G 3GAA 223 034-G 3GAA 253 032-G 3GAA 253 033-G
Full 3/4 Speed load load r/min 100% 75% 895 895 910 905 930 930 945 940 960 960 965 975 972 981 988 987 986 989 988 988 870 905 910 940 920 971 985 985 989 988 60.4 64.0 69.9 72.1 77.6 78.1 80.3 81.8 83.3 84.9 86.1 88.6 89.3 90.5 91.6 92.0 92.7 93.1 93.2 93.2 61.5 70.1 74.4 78.0 79.7 89.7 92.0 93.1 93.4 93.2 60.0 63.6 71.4 73.4 76.2 78.6 81.4 83.1 83.6 85.3 86.1 89.9 90.7 91.4 92.3 93.0 93.3 93.8 94.0 94.1 61.2 70.3 72.6 74.0 80.5 91.2 93.1 94.0 94.1 94.1
1/2 load 50% 55.0 59.5 68.8 71.2 75.6 76.4 80.7 82.5 81.7 83.9 84.3 89.7 90.6 91.0 91.7 92.8 92.9 93.4 93.9 94.0 59.0 69.1 68.7 71.2 80.3 91.2 92.9 94.0 93.9 94.0
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.73 0.58 3.1 1.92 1.9 0.71 0.79 3.3 2.6 2.2 0.73 1.04 3.6 3.8 1.6 0.69 1.59 3.3 5.8 1.8 0.71 1.96 4.0 7.7 2.0 0.66 3 4.0 11.2 1.9 0.73 3.6 3.9 15.1 1.7 0.73 5.3 4.4 22.3 1.8 0.65 7.9 4.3 29.8 1.6 0.68 10 4.6 39.7 1.5 0.67 13.7 6.2 54.4 2.5 0.79 15.4 7.4 73.4 1.7 0.79 22.5 7.5 108 1.9 0.77 31 6.5 146 1.8 0.80 36.4 6.7 178 2.3 0.82 42 6.6 212 2.2 0.83 56.2 7.0 290 2.6 0.82 69.9 6.8 357 2.4 0.84 82.9 6.8 434 2.4 0.84 101 7.1 531 2.6 High-output design 0.72 1.2 3.1 4 2.5 0.76 2 3.9 7.9 2.5 0.71 3.5 4.0 13.6 1.9 0.71 5.7 4.5 22.3 1.9 0.75 7.2 3.8 31.1 1.9 0.77 31.3 7.3 147 1.8 0.83 56.7 6.9 290 2.3 0.83 69.1 6.6 358 2.3 0.83 83.7 7.0 434 2.5 0.84 101 7.1 531 2.6
5.5 6.5 9 10 18 20 26 28 39 46 59 98 125 162 196 218 266 294 378 404 7 11 18 26 32 138 245 300 341 367
42 42 47 47 44 44 49 56 57 61 61 59 59 59 63 63 63 63 63 63 44 47 44 49 76 59 63 63 63 63
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
138 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Current
Torque Tb TN 2.3 2.4 2 1.93 2.1 1.6 3.6 2.2 1.87 1.9 1.8 2.6 2.6 2.8 2.6 2.4 2.3 2.3 2.4 2.3 2.2 2.5 2 2.2 2.3 Moment Sound of inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00092 0.0012 0.0018 0.0024 0.0032 0.0043 0.0069 0.0082 0.01 0.0038 0.0045 0.068 0.085 0.132 0.214 0.45 0.669 0.722 1.404 1.505 0.0015 0.0031 0.0048 0.009 0.0126
Is / IN
Motor type = 8-poles M3AAN 71 A M3AAN 71 B M3AAN 80 A M3AAN 80 B M3AAN 90 S M3AAN 90 L M3AAN 100 LA M3AAN 100 LB M3AAN 112 M M3AAN 132 S M3AAN 132 M M3AA 160 MLA M3AA 160 MLB M3AA 160 MLC M3AA 180 MLA M3AA 200 MLA M3AA 225 SMA M3AA 225 SMB M3AA 250 SMA M3AA 280 SMA = 8-poles M3AAN 71 C M3AAN 80 C M3AAN 90 LB M3AAN 100 LC M3AAN 112 MB
Product code 400 V 50 Hz 3GAA 074 001-E 3GAA 074 002-E 3GAA 084 001-E 3GAA 084 002-E 3GAA 094 001-E 3GAA 094 002-E 3GAA 104 001-E 3GAA 104 002-E 3GAA 114 101-E 3GAA 134 001-E 3GAA 134 002-E 3GAA 164 031-G 3GAA 164 032-G 3GAA 164 033-G 3GAA 184 031-G 3GAA 204 031-G 3GAA 224 031-G 3GAA 224 032-G 3GAA 254 031-G 3GAA 284 031-G 400 V 50 Hz 3GAA 074 003-E 3GAA 084 003-E 3GAA 094 003-E 3GAA 104 003-E 3GAA 114 102-E
Full 3/4 Speed load load r/min 100% 75% 660 670 685 685 695 660 720 695 690 715 715 728 726 727 731 737 739 738 742 740 660 700 680 670 685 49.4 51.4 63.5 67.1 59.4 59.1 70.7 76.0 74.4 82.9 79.9 84.1 84.7 86.1 86.8 90.2 91.0 91.6 92.4 92.3 47.2 57.5 63.1 70.0 73.2 46.0 47.5 62.0 67.2 56.3 59.5 67.1 76.5 75.9 83.0 80.8 85.1 86.0 87.3 88.4 91.3 92.0 92.4 92.9 93.0 44.8 56.0 59.8 65.2 72.5
1/2 load 50% 38.5 39.9 56.3 63.4 49.1 55.2 59.9 74.6 74.1 80.8 79.1 83.7 84.9 86.6 87.8 90.9 91.5 92.0 92.3 92.7 45.0 55.0 53.0 63.8 70.0
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.59 0.44 2.0 1.3 2.4 0.56 0.6 2.1 1.71 2.8 0.62 0.65 2.8 2.5 1.6 0.63 0.85 2.8 3.4 1.4 0.54 1.66 2.7 5 1.6 0.58 2.3 2.1 7.9 1.5 0.47 3.2 3.9 9.9 2.8 0.66 3.1 3.4 15.1 1.7 0.70 4.1 3.2 20.7 1.4 0.62 6.1 3.4 29.3 1.3 0.64 8.4 3.2 40 1.2 0.67 10.2 5.4 52.4 1.5 0.67 13.9 5.6 72.3 1.4 0.65 19.3 4.7 98.5 1.5 0.67 27.3 4.4 143 1.8 0.74 32.4 5.3 194 2.0 0.73 40.1 5.2 239 2.0 0.74 46.8 5.5 284 2.0 0.71 66 5.8 386 2.6 0.74 78.1 5.6 477 2.4 High-output design 0.66 0.83 2.2 2.6 2.3 0.62 1.49 3.3 5 2.5 0.60 2.8 3.0 10.5 1.8 0.70 4.4 3.3 21.3 1.8 0.69 5.7 3.4 27.8 2.1
5.5 6.5 8.5 9.5 13 16 20 23 28 46 53 84 98 137 175 217 266 279 340 403 7 11 18 26 32
40 43 45 50 52 52 46 53 55 56 58 59 59 59 59 60 63 63 63 63 40 45 43 46 52
The two bullets in the product code indicate choice of mounting arrangements, voltage and frequency code (see ordering information page).
= Starting current
Efciency values are given according to IEC 60034-2-1; 2007. Please note that the values are not comparable without knowing the testing method. ABB has calculated the efciency values according to indirect method, stray load losses (additional losses) determined from measuring.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 139
Balancing 052 417 423 424 Vibration acc. to Grade A (IEC 60034-14). Vibration acc. to Grade B (IEC 60034-14). Balanced without key. Full key balancing. S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S R P P
Bearings and Lubrication 036 037 040 041 042 043 058 060 107 128 129 130 194 433 506 Transport lock for bearings. Roller bearing at D-end. Heat resistant grease. Bearings regreasable via grease nipples. Locked drive-end. SPM compatible nipples for vibration measurement Angular contact bearing at D-end, shaft force away from bearing. Angular contact bearing at D-end, shaft force towards bearing. Pt100 2-wire in bearings. Double Pt100, 2-wire in bearings Double Pt100, 3-wire in bearings Pt100 3-wire in bearings. 2Z bearings greased for life at both ends. Outlet grease collector Nipples for vibration measurement: SKF Marlin Quick Connect stud CMSS-2600-3 654 795 796 797 798 799 800 Brakes 412 Built-on brake. R R R R R R R R R NA NA NA NA NA NA NA Provision for vibration sensors (M8x1) Lubrication information plate Grease nipples JIS B 1575 Pt 1/8 Type A Stainless steel SPM Nipples Stainless steel grease nipples Grease nipples at type DIN 3404, thread M10x1 Grease nipples JIS B 1575 Pt 1/8" pin type NA NA NA NA NA NA P P P P P P P P P P NA NA NA P NA NA NA NA NA P NA NA NA NA NA P NA NA NA NA NA P NA NA NA NA NA P NA NA NA NA NA P NA NA P M P P P M P M P P P M P M P P P M P M P P P M P M P P P M P S P P P M P S P P P M P S P P P M P S P P P P P S P P P P NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA P P P P M NA P P P P P M NA P P P P P M NA P P P P P M NA P P P P P M NA P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P NA NA NA NA NA NA NA NA NA NA NA P P P P P NA NA NA NA NA NA P P P P P P P P P P NA NA S NA S P NA NA S NA S P NA NA S NA S P NA NA S NA S P NA NA S NA S P NA NA S NA S P M M P S S S M M P S S S M M P S S S M M P S S S M M P S S S M M P S S S M M P S S S M M P S S S P P P S S S P P P S S S
Branch standard designs 178 204 209 396 Stainless steel / acid proof bolts. Jacking bolts for foot mounted motors. Non-standard voltage or frequency, (special winding). Motor designed for ambient temperature -20 C to -40 C, wtih space heaters (code 450/451 must be added).
1)
S NA P P
S NA P P
S NA P P
S NA P P
S NA P P
S NA P P
M P P P
M P P P
M P P P
M P P P
M P P P
M P P P
M P P P
M S P P
P S P P
P S P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
140 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1) Variant
Frame size 71 80 NA 90 NA 100 NA 112 NA 132 NA 160 P 180 P 200 P 225 P 250 P 280 P 315 P 355 P 400 P 450 P
397
Motor designed for ambient temperature -40 C to -55 C, wtih space heaters (code 450/451 must be added).
NA
Motor designed for ambient temperature -20 C to -40 C. Motor designed for ambient temperature -40 C to -55 C. Corrosion protected stator and rotor core. Special design shaft upwards (V3, V36, V6) for outdoor mounting.
P NA P NA
P NA P NA
P NA P NA
P NA P NA
P NA P NA
P NA P NA
P P S P
P P S P
P P S P
P P S P
P P S P
P P P R
P P P R
P P P NA
P P P NA
P P P NA
Cooling system 044 Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors. 045 Unidirectional fan for reduced noise level. Rotation counter clockwise seen from D-end. Available only for 2-pole motors. 068 183 206 422 514 791 Light alloy metal fan Separate motor cooling (fan axial, N-end). Steel fan Separate motor cooling (fan top, N-end). Separate motor cooling (fan on top) Stainless steel fan cover P NA NA NA NA NA P NA NA NA NA NA P NA NA NA NA NA P NA NA NA NA NA P NA NA NA NA NA P NA NA NA NA NA M P P NA NA NA M P P NA NA NA M P P NA NA NA M P P NA NA P M P P NA NA P M P P P P P M P P P P P M P P P P P P P P P P P P P NA P P P NA NA NA NA NA NA NA NA NA NA NA P P P P P NA NA NA NA NA NA NA NA NA NA NA P P P P P
Drain holes 065 448 Plugged existing drain holes. Draining holes with metal plugs. S NA S NA S NA S NA S NA S NA S P S P M P M P M P M P M P M P P P P P
Hazardous Environments 335 337 456 480 807 812 814 Ex t, Dust group III B T125C Dc (nonconductive dust) acc. IEC/EN60079-31 Ex t, Dust group III C T125 Dc (conductive dust) acc. IEC/EN60079-31 Ex nA design, fullling IEC 60079-15, with certicate. Ex nA II acc. to ATEX directive 94/9/EC, temp. class T3. CSA design, Class I, Div 2 Group A, B, C, D T3 NA Explosion protection according to IECstandards. Ex tD (DIP) motors, temperature class T150 C. Heating elements 450 451
1)
P P S S
P P S S NA S P
P P S S NA S P
P P S S NA S P
P P S S NA S P
P P S S NA S P
M M S S NA S M
M M S S NA S M
P P S S P S M
P P S S P S M
P P S S P S M
P P S S P S M
P P S S P S M
P P S S P S P
P P S S P S P
NA NA S S P S P
S P
P P
P P
P P
P P
P P
P P
M M
M M
M M
M M
M M
M M
M M
M M
P P
P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 141
Code 1) Variant
Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
Insulation system 014 405 Winding insulation class H. Special winding insulation for frequency converter supply. Mounting arrangements 305 Additional lifting lugs. NA NA NA NA NA NA NA NA NA NA NA P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P
Noise reduction 055 Painting 105 106 111 114 115 168 303 754 710 Paint thickness report. Paint thickness = 80 m. Painting system C3M acc. to ISO 12944-5:2007 Special paint colour, standard grade. Painting system C4M acc. to ISO 12944-5:2007 Primer paint only. boxes. Painting system C5M acc. to ISO 12944-5:2007 Thermally sprayed zinc metallaizing with acrylic top coat Protection 005 072 073 076 158 401 403 434 783 Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Sealed against oil at D-end. Draining holes with plugs in open position. Degree of protection IP 65. Protective roof, horizontal motor. Degree of protection IP 56. Degree of protection IP 56, open deck. Labyrinth sealing at D-end. P NA NA P P P NA NA P NA NA P P P NA NA P NA NA P P P NA NA P NA NA P P P NA NA P NA NA P P P NA NA P NA NA P P P NA NA M P P M P M P P M P P M P M P P M P S M P M P P M P S M P M P P M P S M P M P P NA P S M P M P P NA P S M P M P P NA NA S M P M P S NA NA S P P P P S NA NA S NA P P R S P P P P P P M M M M M M M M P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P NA P NA P NA P NA P NA P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P M P M P M P M P M P M P M P M P P P P P P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P NA S P S NA Noise reduction cover for foot mounted motor NA NA NA NA NA NA NA NA NA NA NA R R R R R
Rating & instruction plates 002 004 095 126 135 139 159 161 163 333
1)
Restamping voltage, frequency and output, continuous duty. Additional text on std rating plate (max 12 digits on free text line). Restamping output (maintained voltage, frequency), intermittent duty. Tag plate Mounting of additional identication plate, stainless. Additional identication plate delivered loose. Additional plate with text "Made in ...." Additional rating plate delivered loose. Frequency converter rating plate. Rating data according to quotation. For Export Only
P NA P P P P P P P P
P NA P P P P P P P P
P NA P P P P P P P P
P NA P P P P P P P P
P NA P P P P P P P P
P NA P P P P P P P P
M P M P M M M M M M
M P M P M M M M M M
M P M P M M M M M M
M P M P M M M M M M
M P M P M M M M M M
M P M P M M M M M M
M P M P M M M M M M
M P M P M M M M M M
P P P P P P P P P M
P P P P P P P P P M
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
142 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1) Variant
Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
Shaft & rotor 069 070 164 165 410 Two shaft extensions as per basic catalogue. One or two special shaft extensions, standard shaft material. Shaft extension with closed key-way. Shaft extension with open key-way. Stainless steel shaft (standard or non-standard design). Standards and Regulations 151 421 482 504 Design according to SHELL DEP 33.66.05.31Gen. June 2007 VIK design (Verband der Industriellen Energieund Kraftwirtschaft e.V.). Design according to Neste OY & Jacobs, specication N-114 E, rev 5, 1.12.2010 Design according to Neste OY & Jacobs, specication N-114 E, rev 5, 01.12.2010 with SPM adapter 505 VIK design with ABB standard shaft dimensions (Verband der Industriellen Energieund Kraftwirtschaft e.V.). 540 541 542 775 778 779 782 788 802 China energy label Inmetro certication NBR design Design according to SHELL DEP 33.66.05.31Gen. January 1999 design. GOST Export/Import Certicate (Russia). SASO Export/Import Certicate (Saudi Arabia) Fullling CQST Certication requirements (China) Documentation for Korean KOSHA certication P GOST Kazakhstan certied NA P NA P NA P NA P NA P NA M P M P M P M P M P M P M P M P P P NA NA NA NA NA NA NA NA M M M M M M M P P P NA P NA P NA P NA P NA P NA P P M P M P M P M P M P M P M P P P P P P P NA NA P P NA NA P P NA NA P P NA NA P P NA NA P P NA NA P M P P M M P P M M P P M M P P M M P P M M P P M M P P M M P P P NA P P P NA NA P NA NA NA NA NA NA NA P P P P P P P P P NA NA NA NA NA NA NA P P P P P P P P P P NA NA NA NA NA NA P P P P P P P P P P NA NA NA NA NA NA P P M M M P P P P R NA NA NA NA NA NA M M M M M P P P P P S P R S P R S P R S P R S P R S P R S P R S P R S P R S P R S P R P S P P S P P S P P S P R S P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P
Stator winding temperature sensors 120 328 435 436 439 441 445 446 502 503 511 KTY 84-130 (1 per phase) in stator winding. winding PTC - thermistors (3 in series), 130 C, in stator NA winding. PTC - thermistors (3 in series), 150 C, in stator S winding. PTC - thermistors (2x3 in series), 150 C, in stator winding. PTC - thermistors (3 in series, 130 C & 3 in series, 150 C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Pt-100 2-wire in stator winding, 2 per phase Pt-100 3-wire in stator winding, 1 per phase. Pt-100 3-wire in stator winding, 2 per phase. PTC thermistors (2 x 3 in series), 130 C, in stator winding
1)
NA
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P P P S P P P P P P P
P P P S P P P P P P P
P P NA NA NA NA P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 143
Code 1) Variant
Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
Terminal box 019 021 022 157 180 231 277 278 279 292 293 294 295 296 380 400 402 413 418 447 466 468 469 567 568 728 729 730 732 733 734 736 737 741 743 744 Larger than standard terminal box. Terminal box LHS (seen from D-end). Cable entry LHS (seen from D-end). Terminal box degree of protection IP 65. Terminal box RHS (seen from D-end). Standard cable glands with clamping device. NA NA NA P NA NA NA NA NA P NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA NA P NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA NA P NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA NA P NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA NA P NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA P M M P P NA NA NA NA NA NA NA NA P S NA P P NA NA M M S P P P P M P M S P P M M NA P M M P P NA NA NA NA NA NA NA NA P S NA P P NA NA M M S P P P P M P M S P P M M NA P M M P P NA NA NA NA NA NA NA NA P S NA P P NA P M M P P P P P M P M S P P M M NA P M M P P NA NA NA NA NA NA NA NA P S NA P P NA P M M P P P P P M P M S P P M M NA P M M P P NA NA NA NA NA NA NA NA P S NA P P NA P M M P P P P P M P M S P P M M P P M M P P P NA NA P NA NA NA NA P S S P P M P M M P P P P P M P M S P P M M P P M M P P NA P P NA P P P NA P S S P P M P M M P P P P P M P M S P P M M P P M M P P NA P P NA P P P NA P NA S P P M P R R P P P P P M P M S P P M M P P P P P P NA P P NA NA P P NA P NA S P P NA P R R P P P P P P P P S P P P P NA NA P NA NA P NA P P NA NA P S P P NA S NA P NA P NA NA P P P P P P P P S P P P P
Cable sealing end unit, size small for C-opening NA Cable sealing end unit, size medium for D-opening Cable sealing end unit, size large for D-opening NA Adapter C-C Adapter D-D Adapter E-D Adapter E-2D Adapter E-3D Separate terminal box for temperature detectors, std. material 4 x 90 degr turnable terminal box. Terminal box adapted for Al cables. Extended cable connection, no terminal box. Separate terminal box for auxiliaries, standard material. Top mounted separate terminal box for monitoring equipment. Terminal box at N-end. Cable entry from D-end. Cable entry from N-end. Separate terminal box material: Cast Iron Separate terminal box for heating elements, std. material Standard cable gland, Ex d IIB, armoured cable, double sealing. Aluminum non-drilled ange for cable glands Prepared for NPT cable glands Standard cable gland, Ex d IIB, armoured cable. Standard cable gland, Ex d IIB, non-armoured cable. Standard cable gland, Ex d IIC, armoured cable. Standard cable gland Ex e acc. to ENstandards. Standard cable gland Ex e with clamping device acc. to EN-standards. Motor equipped with Ex e terminal box (EN 50019). Painted non-drilled ange in steel for cable glands Stainless steel non-drilled ange for cable glands. NA NA NA P P R R NA NA R R NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
1)
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
144 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1) Variant
Frame size 71 80 NA NA 90 NA NA 100 NA NA 112 NA NA 132 NA NA 160 M P 180 M P 200 M P 225 M P 250 M P 280 M P 315 M P 355 M P 400 P P 450 P P
Painted steel ange equipped with nickle plated NA brass cable glands Stainless steel cable ange equipped with standard nickle plated brass cable glands NA
Type test report from a catalogue motor, 400V 50Hz. Type test with report for one motor from specic delivery batch. Routine test report. Test according to separate test specication. Customer witnessed testing. Specify test procedure with other codes. Torque/speed curve, type test and multi-point load test with report for one motor from specic delivery batch.
P P P R P P
P P P R P P
P P P R P P
P P P R P P
P P P R P P
P P P R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
P P P R P P
P P P R P P
Nuclear motor testing Vibration level test Vibration spectrum test for one motor from specic delivery batch. Noise level test for one motor from specic delivery batch. Noise spectrum test for one motor from specic delivery batch. Test for one motor from specic delivery batch with ABB frequency converter available at ABB test eld. ABB standard test procedure.
NA P P P R P
NA P P P R P
NA P P P R P
NA P P P R P
NA P P P R P
NA P P P R P
P M P P P P
P M P P P P
P M P P P P
P M P P P P
P M P P P P
NA M P P P P
NA M P P P P
NA M P P P P
NA P P P P P
NA P P P P P
Variable speed drives 181 Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. 470 479 680 701 704 747
1)
NA
NA
NA
NA
NA
NA
Prepared for hollow shaft pulse tacho (L&L equivalent). Mounting of other type of pulse tacho with shaft extension, tacho not included. 2048 pulse tacho, Ex d, tD, L&L 841910001 Insulated bearing at N-end. EMC cable gland. 1024 pulse tacho, Ex d, tD, L&L 841910002
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P M P P
P P P M P P
P P P M P P
P P P P P P
P P P P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 145
Bearings and Lubrication 036 037 039 040 041 043 057 058 059 188 194 195 796 797 798 Transport lock for bearings. Roller bearing at D-end. Cold resistant grease. Heat resistant grease. Bearings regreasable via grease nipples. SPM compatible nipples for vibration measurement 2RS bearings at both ends. Angular contact bearing at D-end, shaft force away from bearing. Angular contact bearing at N-end, shaft force towards bearing. 63-series bearings. 2Z bearings greased for life at both ends. Bearings greased for life. Grease nipples JIS B 1575 Pt 1/8 Type A Stainless steel SPM Nipples Stainless steel grease nipples NA S S NA NA NA NA S S NA NA NA M S S NA R NA S S S NA R NA M S S NA R NA M S S NA R NA S S S M M M S S S M M M S S S M M M S S S M M M S S S M M M S R R M M M NA NA M M M M M M M M M M M NA M NA M M M M M M M M M M M M M M M M M M M M NA NA M M NA NA NA NA M M NA NA M P M M P R M P M M P R M P M M P R M P M M P R M M NA NA M M M M NA NA M M M M NA NA M M M M NA NA M M M M NA NA M M M M NA NA S M
Branch standard designs 071 142 178 209 217 232 425 Cooling Tower duty Manilla connection. Stainless steel / acid proof bolts. Non-standard voltage or frequency, (special winding). Cast iron D-end shield (on aluminum motor). Cast iron N-end shield (on aluminium motor). Corrosion protected stator and rotor core. NA NA P NA NA P M NA P M NA P M NA P M NA P S S P S S P S S P S S P S S P S S P NA NA M P NA NA M P NA P M P NA P M P R P M P R P M P P P M P P P M P P P M P P P M P P P M P P P M P
Cooling system 053 068 075 189 Metal fan cover. Light alloy metal fan Cooling method IC 418 (without fan). Separate motor cooling, IP 44, 400V, 50Hz (fan axial, N-end). Documentation 141 Binding dimension drawing. M M M M M M M M M M M M M M R NA M M R NA M M P NA M M P NA M M P NA M M P NA S M NA R S M NA R S M NA R S M NA R S M NA R S M NA R
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
146 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant 71 80 90 100 112 132 160 180 200 225 250 280
Hazardous Environments 452 453 480 DIP/Ex tD acc. to ATEX directive 94/9/EC, T= 125 C, cat. 3D, IP 55 DIP/Ex tD acc. to ATEX directive 94/9/EC, T= 125 C, cat. 2D, IP 65 Ex nA II acc. to ATEX directive 94/9/EC, temp. class T3. Heating elements 450 451 Heating element, 100-120V. Heating element, 200-240V. M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M NA NA P P NA NA NA NA NA NA NA NA M M M M M M M M M M M M
Insulation system 014 405 406 Winding insulation class H. Special winding insulation for frequency converter supply. Winding for supply >690<=1000 Volts. NA NA NA NA NA NA R R P P P P R R R R P P P P P P P P P P P P P P P P P P P P
Mounting arrangements 007 008 009 047 048 066 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). Modified for non-standard mounting position (please specify IM xxxx), (must be ordered for all mounting arrangements excluding IM B3 (1001), IM B5 (3001), IM B35 (2001), B34 (2101) & B14 (3601). 200 218 219 220 223 224 226 227 229 233 234 235 243 244 245 255
1)
NA M M M M M
NA M M M M M
NA M M M M M
NA M M M M M
NA M M M M M
NA M M M M M
M M M M NA M
M NA M NA NA M
M NA M NA NA M
M NA M NA NA M
M NA M NA NA M
M NA M NA NA M
Flange ring holder. Flange ring FT 85. Flange ring FT 100. Flange ring FF 100. Flange ring FF 115. Flange ring FT 115. Flange ring FF 130. Flange ring FT 130. Flange FT 130. Flange ring FF 165. Flange ring FT 165. Flange FF 165. Flange ring FF 215. Flange ring FT 215. Flange FF 215. Flange FF 265.
M M M M M M M M NA M M NA NA NA NA NA
M M M M M M M M NA M M NA NA NA NA NA
M M M M M M M M NA M M M NA NA NA NA
M NA NA NA NA M M M M M M NA M M M NA
M NA NA NA NA M M M M M M NA M M M NA
M NA NA NA NA NA NA NA NA NA NA NA M M NA M
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 147
Code 1)
Variant 71 80 NA M M M M M M M M M M 90 M M M M M M M M M M M 100 NA M M M M M M M M M M 112 NA M M M M M M M M M M 132 NA M M M M M M M M M M 160 NA NA NA NA NA NA NA NA NA NA NA 180 NA NA NA NA NA NA NA NA NA NA NA 200 NA NA NA NA NA NA NA NA NA NA NA 225 NA NA NA NA NA NA NA NA NA NA NA 250 NA NA NA NA NA NA NA NA NA NA NA 280 NA NA NA NA NA NA NA NA NA NA NA
260 306 307 308 309 310 311 312 315 316 319 Painting 114 168
Flange FT 115. IM 1001 foot mounted, from IM 3601 (B3 from B14). IM 2101 foot/flange mounted, IEC flange, from IM 3601 (B34 from B14). IM 2001 foot/flange mounted, IEC flange, from IM 3601 (B35 from B14). IM 1001 foot mounted, from IM 3001 (B3 from B5). IM 2101 foot/flange mounted, IEC flange, from IM 3001 (B34 from B5). IM 2001 foot/flange mounted, IEC flange, from IM 3001 (B35 from B5). IM 1001 foot mounted, from IM 2101 (B3 from B34). IM 2001 foot/flange mounted, IEC flange, from IM 2101 (B35 from B34). IM 1001 foot mounted, from IM 2001 (B3 from B35). IM 2101 foot/flange mounted, IEC flange, from IM 2001 (B34 from B35).
NA M M M M M M M M M M
M NA
M NA
M P
M P
M P
M P
M NA
M NA
M NA
M NA
M NA
M NA
Protection 005 072 073 158 211 403 784 Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Sealed against oil at D-end. Degree of protection IP 65. Weather protected, IP xx W. Degree of protection IP 56. Gamma-seal at D-end. M M NA M M M M M M NA M M M M M M NA M M M M M M NA M M M M M M NA M M M M M M NA M M M M M M NA NA NA M M M M NA NA NA M M M M NA NA NA M M M M NA NA NA M M M M M NA NA M M M M NA NA NA M M
Rating & instruction plates 002 003 004 095 098 135 138 139 160 161
1)
Restamping voltage, frequency and output, continuous duty. Individual serial number. Additional text on std rating plate (max 12 digits on free text line). Restamping output (maintained voltage, frequency), intermittent duty. Stainless rating plate. Mounting of additional identification plate, stainless. Mounting of additional identification plate, aluminium. Additional identification plate delivered loose. Additional rating plate affixed. Additional rating plate delivered loose.
M M NA M M M M M P M
M M NA M M M M M P M
M M M M M M M M M M
M M M M M M M M M M
M M M M M M M M M M
M M M M M M M M M M
R S M R M NA M M M M
R S M R M NA M M M M
R S M R M NA M M M M
R S M R M NA M M M M
R S M R M NA M M M M
R S M R M NA M M M M
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
148 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant 71 80 R S 90 R S 100 R S 112 R S 132 R M 160 M S 180 M S 200 M S 225 M S 250 M S 280 M S
163 198
Frequency converter rating plate. Rating data according to quotation. Aluminum rating plate.
R S
Shaft & rotor 069 070 131 165 410 Two shaft extensions as per basic catalogue. One or two special shaft extensions, standard shaft material. Motor delivered with half key (Key not exceeding shaft diameter) Shaft extension with open key-way. Stainless steel shaft (standard or non-standard design). Standards and Regulations 011 779 Fulfilling CSA Energy Efficiency Verification (code 010 included). SASO Export/Import Certificate (Saudi Arabia) NA NA NA NA NA NA M M M M M M NA NA NA NA NA NA R R R R R R NA NA NA NA P P P P P P P P P R P R P R P R P R P R NA NA M M M M M M M M M M NA NA NA NA P P P P P P P P P R P R P R P R P R P R
Stator winding temperature sensors 435 436 437 439 440 441 442 445 446 PTC - thermistors (3 in series), 130 C, in stator winding. PTC - thermistors (3 in series), 150 C, in stator winding. PTC - thermistors (3 in series), 170 C, in stator winding. PTC - thermistors (2x3 in series), 150 C, in stator winding. PTC - thermistors (3 in series, 110 C & 3 in series, 130 C), in stator winding. PTC - thermistors (3 in series, 130 C & 3 in series, 150 C), in stator winding. PTC - thermistors (3 in series, 150 C & 3 in series, 170 C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Pt-100 2-wire in stator winding, 2 per phase NA NA NA NA R R R R M R M R M M M M M M M M M M M M NA NA P P M M M M M M M M NA NA M M M M M M M M M M NA NA P P P P R R R R R R NA NA M M M M M M M M M M M M P P M M M M M M M M M M M M M M S S S S S S M M M M M M M M M M M M
Terminal box 015 016 017 019 021 022 136 137 180 230 375 376
1)
Motor supplied in D connection. 9 terminals in terminal box Motor supplied in Y connection. Larger than standard terminal box. Terminal box LHS (seen from D-end). Cable entry LHS (seen from D-end). Extended cable connection, standard terminal box. Extended cable connection, low terminal box, Flying leads. Terminal box RHS (seen from D-end). Standard metal cable glands. Standard plastic cable gland Two standard plastic cable glands
M NA M NA NA NA NA P NA M M M
M NA M NA NA NA NA P NA M M M
M P P NA NA NA P P NA M M M
M P P NA NA NA P P NA M M M
M P NA NA NA NA P P NA M M M
M P NA NA NA NA P P NA M M M
M NA M NA NA S R R NA M NA NA
M NA M NA NA S R R NA M NA NA
M NA M M P R R R P M NA NA
M NA M M P R R R P M NA NA
M NA M M P R R R P M NA NA
M NA M NA P R R R P M NA NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 149
Code 1)
Variant 71 80 NA NA NA NA NA NA M M M NA NA 90 NA NA NA NA NA NA M M M NA NA 100 NA NA NA R NA NA M M M NA NA 112 NA NA NA R NA NA M M M NA NA 132 NA NA NA R NA NA M M M NA NA 160 R NA NA M R NA M R R S M 180 R NA NA M R NA M R R S M 200 NA P R M R M M R R M M 225 NA P R M R M M R R M M 250 NA P R M R M M R R M M 280 NA P R M R M M R R P M
400 402 413 418 467 729 731 736 737 739 740 Testing 140 145 146 147 148 153 221 222
4 x 90 degr turnable terminal box. Terminal box adapted for Al cables. Extended cable connection, no terminal box. Separate terminal box for auxiliaries, standard material. Lower than standard terminal box and rubber extended cable. Cable length 2m. Aluminum non-drilled flange for cable glands Two standard metal cable glands. Standard cable gland Ex e acc. to EN-standards. Standard cable gland Ex e with clamping device acc. to EN-standards. Prepared for metric cable glands according to DIN 42925, draft aug. 1999. Prepared for PG cable glands.
NA NA NA NA NA NA M M M NA NA
Test confirmation. Type test report from a catalogue motor, 400V 50Hz. Type test with report for one motor from specific delivery batch. Type test with report for motor from specific delivery batch, customer witnessed. Routine test report. Reduced test for classification society. Type test and multi-point load test with report for one motor from specific delivery batch. Torque/speed curve, type test and multi-point load test with report for one motor from specific delivery batch.
M M M M M M M NA
M M M M M M M NA
M M M M M M M P
M M M M M M M P
M M M M M M M P
M M M M M M M P
M M M M M M M M
M M M M M M M M
M M M M M M M M
M M M M M M M M
M M M M M M M M
M M M M M M M M
Vibration level test Noise level test for one motor from specific delivery batch. Noise spectrum test for one motor from specific delivery batch.
M M NA
M M NA
P P P
P P P
P P NA
P P NA
M M R
M M R
M M R
M M R
M M R
M M R
Variable speed drives 470 474 Prepared for hollow shaft pulse tacho (L&L equivalent). Separate motor cooling (fan axial, N-end) and prepared for hollow shaft tacho (L&L equivalent). 476 477 570 Separate motor cooling (fan axial, N-end) and 1024 pulse tacho (L&L 861007455-1024). Separate motor cooling (fan axial, N-end) and 2048 pulse tacho (L&L 861007455-2048). Prepared for hollow shaft pulse tacho (L&L 503).
1)
R R
R R
R R
R R
R R
R R
M R
M R
M R
M R
M R
M R
R R R
R R R
R R NA
R R NA
R R R
R R R
R R M
R R M
R R M
R R M
R R M
R R M
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
150 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant 71 80 NA NA 90 NA NA 100 NA NA 112 NA NA 132 NA NA 160 R R 180 R R 200 R R 225 R R 250 R R 280 R R
574 578
Separate motor cooling (fan axial, N-end) and prepared for hollow shaft tacho (L&L 503). Separate motor cooling, IP 44, 400V, 50Hz (fan axial, N-end) and prepared for hollow shaft tacho (L&L 503).
NA NA
Separate motor cooling, IP 44, 400V, 50Hz (fan axial, N-end) and 1024 pulse tacho (L&L 503). Separate motor cooling, IP 44, 400V, 50Hz (fan axial, N-end) and 2048 pulse tacho (L&L 503). Insulated bearing at N-end. EMC cable gland.
NA NA NA R
NA NA NA R
NA NA NA R
NA NA NA R
NA NA NA R
NA NA NA R
R R NA R
R R NA R
R R M R
R R M R
R R M R
R R M R
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 151
HD
M000267 M000268 M000270
PN
H K A
B B
M S
M000269
M000271
M000272
45
GA
45
Sizes 80 to 200 Sizes 225 to 450 Protective roof, variant code 005
Motor size
71 80 90 100 112 132 160 180 200 225 250 280 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_ 450
IM 1001, IM B3 AND IM 3001, IM B5 D GA F E poles poles poles poles 2 4-8 2 4-8 2 4-8 2 4-8 14 14 16 16 5 5 30 30 19 19 21.5 21.5 6 6 40 40 24 24 27 27 8 8 50 50 28 28 31 31 8 8 60 60 28 28 31 31 8 8 60 60 38 38 41 41 10 10 80 80 42 42 45 45 12 12 110 110 48 48 51.5 51.5 14 14 110 110 55 55 59 59 16 16 110 110 55 60 59 64 16 18 110 140 60 65 64 69 18 18 140 140 65 75 69 79.5 18 20 140 140 65 80 69 85 18 22 140 170 65 90 69 95 18 25 140 170 70 100 62.5 90 20 28 140 210 70 100 62.5 90 20 28 140 210 70 100 62.5 90 20 28 140 210 80 110 85 126 22 28 170 210 80 100 85 106 22 28 170 210 120 127 32 210
L max poles 2 4-6 264 264 321 321 357 357 381 381 403 403 533 533 808 808 826 826 774 774 841 871 875 875 1088 1088 1174 1204 1285 1315 1409 1479 1514 1584 1764 1834 1851 1891 1851 1891 2187
IM 1001, IM B3 A B B'
HD
IM 3001, IM B5 M N P
Protective roof DS LS 2 4-8 272.5 272.5 331 331 360 368.5 368.5 430 395 395 505 417 417 505 551.5 551.5 590 328 756 756 359 756 756 414 844 844 462 921 951 506 965 965 555 1190 1190 624 1290 1320 624 1401 1431 720 1476 1546 720 1528 1703 720 1633 1703 810 1860 1900 810 1860 1900 On request
112 125 140 160 190 216 254 279 318 356 406 457 508 508 610 610 610 710 686 800
90 100 100 140 140 140 210 241 267 286 311 368 406 457 500 560 710 900 710 1000
125 178 254 279 305 311 349 419 457 508 560 630 900 1000 800 1120
45 50 56 63 70 89 108 121 133 149 168 190 216 216 254 254 254 224 280 250
178 195 219 247 259 300 499 539 536 583 646 759 852 852 958 958 958 1045 1045 1169
130 165 165 215 215 265 160 180 200 225 250 280 315 315 355 355 355 400 400 450
110 130 130 180 180 230 300 300 350 400 500 500 600 600 740 740 740 940 740 1080
160 200 200 250 250 300 250 250 300 350 450 450 550 550 680 680 680 880 680 1000
10 12 12 15 15 15 350 350 400 450 550 550 660 660 800 800 800 1000 800 1150
LA 8 8 10 10 10 12
S M6 M6 M8 M8 M8 M10
S M6 M6 M8 M8 M8 M10
A, B D, DA F, FA H N C, CA
0,8 ISO k6 < 50mm ISO m6 > 50mm ISO h9 -0.5 ISO j6 0.8
Above table gives the main dimensions in mm. For detailed drawings please see our web-pages www.abb.com/motors&generators or contact ABB.
152 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000231
M000230
HD
M000267 M000268
H K A
Sizes 90 to 200
B B
M000269
M000271
D GA
45
45
Motor size
M3AAN 71 80 M3AAN 90 S 90 L 100 112 132 M3AA 160 M/MA 2-8, L 2-6, LB 2-4 160 L 8, LB 6-8 42 180 M 2-4, L 6-8, 48 180 200 200 225 225 225 250 250 280 280 280 LB 2 L 4, LB 4-8 MLD-2,-C 4 all exc. above SMB, -C SMA,-B,-C SMD SMA,-B SMC SMA SMB SMB 48 55 55 55 60 55 60 60 65 65 65
IM 1001, IM B3 AND IM 3001, IM B5 D GA F E poles poles poles poles 2 4-8 2 4-8 2 4-8 2 4-8 14 14 16 16 5 5 30 30 19 19 21.5 21.5 6 6 40 40 24 24 27 27 8 8 50 50 24 24 27 27 8 8 50 50 28 28 31 31 8 8 60 60 28 28 31 31 8 8 60 60 38 41 41 41 10 10 80 80 42 42 45 45 12 12 110 110 42 48 48 55 55 55 60 60 65 65 75 75 75 45 51.5 51.5 59 59 59 64 59 64 64 69 69 69 45 12 51.5 14 51.5 14 59 16 59 16 59 64 64 69 69 79.5 79.5 79.5 16 18 16 18 18 18 18 18 12 14 14 16 16 16 18 18 18 18 20 20 20
L max poles 2 240 265.5 282 307 349 361 447 602.5
IM 1001, IM B3 A B B' 4-8 240 265.5 282 307 349 361 447 602.5
M000272
M000270
PN
HD
IM 3001, IM B5 M N P
178 254 254 279 279 305 305 311 311 311 349 349 419 419 419
45 50 56 56 63 70 89 108
7 10 10 10 12 12 12 15
10 12 12 12 15 14.5 14.5 19
110 110 643.5 643.5 254 210 110 110 680 680 279 241 110 110 700.5 700.5 279 241 110 110 814 814 318 267 110 110 774 774 318 267 110 140 110 140 140 140 140 140 110 140 140 140 140 140 140 140 836 866 861 875 900 875 900 900 836 891 891 875 900 875 900 900 356 356 356 406 406 457 457 457 286 286 286 311 311 368 368 368
108 370 121 405 121 405 133 533 133 533 149 149 149 168 168 190 190 190 578 578 578 626 626 656 656 656
15 160 300 15 180 300 15 180 300 18 200 350 18 200 350 18 18 18 22 22 24 24 24 225 225 225 250 250 280 280 280 400 400 400 500 500 500 500 500
250 350 19 250 350 19 250 350 19 300 400 19 300 400 19 350 350 350 450 450 450 450 450 450 450 450 550 550 550 550 550 19 19 19 19 19 19 19 19
IM 3601, IM B14
Motor size 71 80 90 100 112 132
Tolerances:
S M6 M6 M8 M8 M8 M10
A, B D, DA F, FA H N C, CA
0,8 ISO k6 < 50mm ISO m6 > 50mm ISO h9 -0.5 ISO j6 0.8
Above table gives the main dimensions in mm. For detailed drawings please see our web-pages www.abb.com/motors&generators or contact ABB.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 153
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Stator frame Endshield, D-end Screws for endshield, D-end Endshield, N-end Screws for endshield, N-end Rotor with shaft Key, D-end Terminal box Terminal board Intermediate flange Screws for terminal box cover Outer bearing cover, D-end Valve disc with labyrinth seal, D-end; standard in 2-pole motors (V-ring in 4-8 pole) Bearing, D-end Inner bearing cover, D-end Screws for bearing cover, D-end
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Outer bearing cover, N-end Seal, N-end Wave spring Valve disc, N-end Bearing, N-end Inner bearing cover, N-end Screws for bearing cover, N-end Fan Fan cover Screws for fan cover Rating plate Regreasing plate Grease nipple, D-end Grease nipple, N-end SPM nipple, D-end SPM nipple, N-end
154 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000220
Certicate examples
M000730
2(2)
2011-06-22 Certificates: 3-phase induction motors, series M2GP, M3JP, M3KP, M3GP, M3HP, M3LP
Motor type, IEC frame size M3JP/M3KP 80 M3JP/M3KP 90 M3JP/M3KP 100-112 M3JP/M3KP 132 M3JP/M3KP 160 M3JP/M3KP 180 M3JP/M3KP 160 Gen.H M3JP/M3KP 180 Gen.H M3JP/M3KP 200 M3JP/M3KP 225 M3JP/M3KP 250 M3JP/M3KP 280 M3JP/M3KP 315 M3JP/M3KP 355 M3JP/M3KP 400 M3HP 80-90 M3HP 100-112 M3HP 132 M3HP 160 M3HP 180 M3HP 160 Gen.H M3HP 180 Gen.H M3HP 200 M3HP 225 M3HP 250 M3HP 280 M3HP 315 M3HP 355 M3HP 400 M2GP 71-250 M3GP 80 - 400 M3GP 160 - 180 Gen.H M3GP/M3LP 450 M3GP 160 180 Gen.H IP 65 M3GP 160 180 Gen.H M3GP/M3LP 450 M2GP 71-250 M3GP 80-400 LCIE 09 ATEX 1010 * LCIE 06 ATEX 6088 LCIE 05 ATEX 6160 LCIE 06 ATEX 6089 2009 2006 2005 2006 Certification number LCIE 04 ATEX 6150 LCIE 04 ATEX 6151 LCIE 04 ATEX 6152 LCIE 04 ATEX 6061 LCIE 00 ATEX 6023 LCIE 00 ATEX 6028 LCIE 09 ATEX 3004X LCIE 09 ATEX 3005X LCIE 00 ATEX 6027 LCIE 00 ATEX 6029 LCIE 00 ATEX 6030 LCIE 01 ATEX 6078 LCIE 01 ATEX 6079 LCIE 03 ATEX 6060 LCIE 04 ATEX 6087 LCIE 06 ATEX 6047 LCIE 06 ATEX 6048 LCIE 06 ATEX 6049 LCIE 01 ATEX 6015 LCIE 01 ATEX 6021 LCIE 09 ATEX 3022 LCIE 09 ATEX 3023 LCIE 01 ATEX 6022 LCIE 01 ATEX 6023 LCIE 01 ATEX 6024 LCIE 02 ATEX 6071 LCIE 02 ATEX 6072 LCIE 03 ATEX 6022 LCIE 04 ATEX 6013 LCIE 05 ATEX 6160 LCIE 06 ATEX 6089 LCIE 09 ATEX 1010 * LCIE 06 ATEX 6088 LCIE 09 ATEX 3016 Year of CE-marking 2004 2004 2004 2004 2000 2000 2009 2009 2000 2000 2000 2001 2001 2003 2004 2006 2006 2006 2001 2001 2009 2009 2001 2001 2001 2002 2002 2003 2004 2005 2006 2009 2006 2009
EC Declaration of Conformity
The Manufacturer: ABB Oy Motors Motors and Generators P.O. Box 633 Strmbergin puistotie 5A FIN - 65101 Vaasa, Finland
hereby declares that the products: 3-phase induction motors, series M2GP, M3JP, M3JC, M3KP, M3KC, M3GP, M3HP and M3LP; as listed on page 2 in this document, fulfill provisions of the relevant Council Directives:
In addition: II 2 D Ex tD A21 / IP 65 or II 3 D Ex tD A22 / IP 55, IP65 (3D not for M3JP/KP160-180 Gen.H)
Increased safety
- that the state of the art of these standards do not modify the result of the assessment carried out by LCIE which issued the EC type examination certificates according to former editions of the standard series. - that listed motors conform to the requirements of annex II of the directive 94/9/EC clause 1.2.7 by applying the standards series EN 60034. Directive 2009/125/EC (EuP of 21st October 2009) by fulfilling the requirements of the standard IEC 60034-30: 2008 Ed 1 in respect of the efficiency class. Note: When installing motors for converter supply applications additional requirements must be respected regarding the motor as well as the installation, as described in the appropriate dedicated addendum.
Signed by
Non-sparking II 3G Ex nA II T2 -T3
Title Date
ABB Oy
Motors and Generators Postal address P.O. Box 633 FI-65101 Vaasa FINLAND Visiting Address Strmbergin Puistotie 5 A FI-65320 Vaasa FINLAND Telephone +358 10 22 11 Telefax +358 10 22 47372 Internet www.abb.fi e-mail: first name.last name @fi.abb.com Business Identity Code: 0763403-0 Domicile: Helsinki
M000725-1a
1) 2)
Notified Body ( ExNB ): LCIE (0081) ; Av. Du Gnral Leclerc. 33, 92266 Fontenay-aux-Roses, France *) Voluntary Type Examination Certificate for equipment category 3
3GZF500930-988
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 155
M000725-2a
M000731
C3 medium according to ISO/EN 12944-5 Cast iron, EN-GLJ-150 or better, integrated with stator Forged steel, detachable feet
Material
Paint colour shade Corrosion class Bearings D-end 2-8 pole N-end 2- 8 pole Axially-locked bearings Bearing seal Lubrication SPM-nipples Rating plate Terminal box Material Frame material Inner bearing cover
C3 medium according to ISO/EN 12944-5 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6208-2Z/C3 6309/C3 6310/C3
6202-2Z/C3
6203-2Z/C3
6204-2Z/C3
6205-2Z/C3
6208-2Z/C3
6309/C3
6310/C3
Gamma ring Permanent grease lubrication. Stainless steel Cast iron, EN-GLJ-150 or better Cast iron, EN-GJL-200 or better Cover material Cast iron, EN-GLJ-150 or better Cast iron, EN-GJL-200 or better Screws Steel 8.8, zinc electroplated and chromated 2xM16 2 x M25 2 x M32 2 x M40 x 1.5 Regreasable bearings As standard
Connections
6 terminals for connection with cable lugs (not included) Polypropylene. Reinforced with glass bre. Steel Blue, Munsell 8B 4.5/3.25 Hot dip galvanized steel
Stator winding
Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method
Material
On request
156 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Cast iron, EN-GJL-200 or better, integrated with stator Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6312/C3 6313/C3 6315/C3 6316/C3 6319/C3 6316/C3 6316M/C3 6322/C3 6316M/C3 6316/C3 6317/C3 6324/C3 6317/C3 6319/C3 6317M/C3 6326M/C3 6317M/C3 6322/C3
6 terminals for connection with cable lugs (not included) Polypropylene. Reinforced with glass bre. Polypropylene reinforced with glass bre or aluminum.
Fan cover
Hot dip galvanized steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors Pressure die-cast aluminum Half key balancing Closed Open 60 W 120 W 200 W
Stator winding
Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method
Material
Optional
25 W
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 157
Bearing seal
D-end N-end
Lubrication Terminal box Material Surface treatment Screws Connections Knock-out openings Terminal box Screws Max Cu-area, mm2 Fan Fan cover Stator winding Material Material Material Insulation class Winding protection Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method
1
Die-cast aluminum alloy, base integrated with stator Powder coating based on polyester resin, 30 m Steel 5G, galvanised 2 x (M20 + M20) Caple lugs. 6 terminals. M4 4 6 2 x (M25 + M20) Screw terminal. 6 terminals Cable lugs. 6 terminals M5 10
Polypropylene reinforced with 20 % glass bre. Steel sheet Copper Insulation class F. Temperature rise class B, unless otherwise stated. Optional Die-cast aluminum Half key balancing Closed 8W 25 W
Material
158 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Permanently lubricated shielded bearings. Die-cast aluminum alloy base integrated with stator Surface treatment Screws Polyester powder paint 50 m Steel 5G. Galvanised. (2 x M40) + (2 x M40 + M16) 2 x FL13, 2 x M40 + 1 x M16 2 x FL21, 2 x M63 + 1 x M16 (voltage code S) Terminal box Screws Max Cu-area, mm2 Caple lugs. 6 terminals. M6 35 M10 70 Phosphated, polyester paint. Deep-drawn steel sheet, bolted to stator.
Connections
Polypropylene. Reinforced with 20% glass bre. Steel sheet. Galvanized. Copper Insulation class F. Temperature rise class B, unless otherwise stated. PTC-thermistors, 150 C Die-cast aluminum Half key balancing Closed 25 W 50 W
Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method
Material
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 159
160 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition protection motors / Protection by enclosure Ex t IIIB/IIIC T125 C Db/Dc Totally enclosed squirrel cage three phase low voltage motors, Sizes 71 to 400, 0.25 to 710 kW
www.abb.com/motors&generators > Motors for explosive atmospheres >> Dust ignition protection motors
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 161
Mechanical design
Drain holes
Dust ignition protection motors in are delivered without drain holes or drain holes enclosed position.
Bearing seals
The following bearing seals are used as standard, special seals like radial seals are available as option. Please see variant code section.
Bearing seals in Ex t (M3GB) IE2 motors Frame size 71-250 280-315 280-315 355 355 400 400 Number of poles 2-12 2 4-12 2 4-12 2 4-12 D-end Gamma ring Labyrinth seal V-ring Labyrinth seal Labyrinth seal Labyrinth seal Labyrinth seal N-end Gamma ring V-ring V-ring V-ring V-ring Labyrinth V-ring Bearing seals in Ex t (M3AAD)aluminum motors 2D Frame size 90-132 Number of poles D-end 2-8 V-ring N-end V-ring
Bearing seals in Ex t (M3AAD and M3AA) aluminum motors 3D Frame size 71-180 200-280 Number of poles D-end 2-8 V-ring 2-8 V-ring N-end Labyrinth seal V-ring
Bearing seals in Ex t (M3GP) IE2 motors Frame size 200-250 280 Number of poles D-end 2-12 Gamma ring 2-12 Labyrinth seal N-end Gamma ring Labyrinth seal
162 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
of uninterrupted type fulfilling the latest requiremets for Ex t motors. If no ordering information on the cable is given, it is assumed to be p.v.c. -insulated non-armoured and termination parts are supplied according to the table on the following pages. To enable the supply of suitable terminations for the motor, please state cable type, quantity, size and outer diameter when ordering. Ex t motors in size 160 and larger are delivered as standard with cable glands according to the below table. Different glands can be provided separately as an option. Note: For 500 V motor information please contact ABB!
63 210/1 370/1 370/1 370/1 750/1 370/1 750/1 370/1 370/1 750/1 750/1
2x19-27 2x34-45 2x32-49 2x32-49 2x32-49 2x46-60 2x32-49 2x46-60 2x32-49 2x32-49 2x46-60 2x46-60
Earthings on motor
80-132 160-180 200-250 280-315 355-400 Frame M6 M6 M8 M10 M10 Terminal box M6 M6 M8 2xM10 2xM12
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 163
Related variant codes: 729 Aluminum non-drilled flange for gable glands. 730 Prepared for NPT glands 732 Standard cable gland, Ex d IIB, armoured cable. 733 Standard cable gland, Ex d IIB, non-armoured cable. 743 Painted non-drilled flange in steel for cable glands. 744 Stainless steel non-drilled flange for gable glands. 745 Painted steel cable flange equipped with nickle plated brass cable glands. 746 Stainless steel cable flange equipped with nickle plated brass cable glands.
Cable glands and cable sealing end units Cable glands The table below shows the selction of cable gland types and possible cable outer diameter of each size. For armoured and NPT cable glands please contact ABB.
Outer diameter, mm Variant code 745 Painted steel ange equipped with brass cable glands Motor sizes 71-400: M16 M20 M25 M32 M40 M50 M63 M75 M90 4-9 8-14 10-16 16-21 18-27 26-35 32-49 46-60 55-70
Variant code 737 Standard cable gland Ex e with clamping device acc. to EN-Standards 4-9 8-14 10-16 16-21 18-27 26-35 32-49 NA NA
164 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Auxiliary terminal box It is possible to equip the motors from frame size 160 upwards with one or several auxiliary terminal boxes for connection of auxiliaries like heaters or temperature detectors. The standard auxiliary terminal box is made of aluminum and equipped with M20 glands for entry of the connection cables. As an option cast iron terminal box is available. In motor sizes 160 to 180 the material of auxiliary terminal box is cast iron. Connection terminals are of a spring-loaded type for quick and easy connection. These are suitable for up to 2.5 mm wires. Auxiliary terminal boxes are equipped with an earthing terminal. Small, aluminum auxiliary terminal box (80 x 125 mm, for max. 12 wires) Earthing size M4
As standard the first auxiliary terminal box is located on RHS seen from D-end. Related variant codes: 418 Separate terminal box for auxiliaries, standard material (all connections of temperature detectors and heaters will be put in same box). 380 Separate terminal box for temperature detectors, standard material. 568 Separate terminal box for heating elements, standard material. 569 Separate terminal box for brakes, standard material. 567 Separate terminal box material: Cast iron.
Large, aluminum auxiliary terminal box (80 x 250 mm, for max. 30 wires) Earthing M4
Cast iron auxiliary terminal box (211 x 188 mm, for max. 30 wires) Earthing M6
M000439
M000440
Standard cable entry size M20. Number of entries depends on the terminal box type and number of selected auxiliaries.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 165
M000782
M000368c
M000365
Motor sizes 280 to 355 Top- and side-mounted Terminal boxes 160/1, 370/1
Motor sizes 315 to 400 Top- and side-mounted Terminal box 750/1
M000785
166 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000786
M000784
M000521
M000017
M000018
M000501
Connections
The terminal block is provided with six terminals for connecting Cu-cable. The terminals are marked in accordance with IEC 60034-8. Connection openings
Motor size 71-80 90-112 132 132
1) 2)
Opening Knock-out opening Knock-out opening Knock-out opening Knock-out opening Knock-out opening 2 x FL 13 2 x FL 21
2) 2)
Metric cable entry 2 x ( 2 x M20 ) 2 x (M25 + M20) 2 x (M25 + M20) 2 x (M40 x M32 + M12) 2 x (2 x M40) + M16) 1 x (2 x M40 + M16) 1 x (2 x M63 + M16)
SM_
Method of connection Cable lug Screw terminal Cable lug Cable lug Cable lug Cable lug Cable lug
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 167
M000500
If the radial force is applied between points X0 and Xmax, the permissible force FR can be calculated from the following formula: FR = FX0 - X (FX0 - FXmax) E E = length of shaft extension in basic version
168 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Cast iron motors, sizes 160 to 400 Permissible radial forces according to L10 principle Dust ignition protection motors
Motor size 160 ML_ 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 Poles Lengt of shaft extension E (mm) 110 110 110 110 110 110 110 110 110 110 110 110 110 140 140 140 140 140 140 140 140 140 140 140 140 170 170 170 140 170 170 170 140 170 170 170 140 210 210 210 140 210 210 210 140 210 210 210 170 210 210 210 170 210 210 210 Ball bearings 40,000 hours FX0 [N] 2530 3180 3650 4020 2900 3660 4190 4620 3830 4830 5520 6080 4350 5490 6280 6920 4390 6790 7760 8550 5840 7260 8300 9150 5810 9030 10310 11360 5850 9000 10270 11330 5880 9090 10270 11360 5790 11930 13630 15050 5770 11980 13650 15090 5670 12020 13680 15160 4450 12120 13750 15280 4450 12120 13750 15280 FXmax[N] 2120 2670 3060 3370 2440 3080 3520 3880 3160 3980 4550 5010 3660 4420 5060 5570 4350 5480 6270 6900 4900 6110 6980 7700 4960 7470 8530 9400 5080 7620 8700 9590 5210 7870 8890 9840 5090 9890 11300 12470 5120 10090 11500 12710 5140 10420 11860 13150 3970 10550 11970 13310 3970 10550 11970 13310 Roller bearings 40,000 hours FX0 [N] 6400 7880 8900 9700 6970 8580 9700 10570 9500 11710 13230 14420 11650 14340 16190 17660 15420 18980 21440 23370 16500 20100 22690 24740 16540 26590 30030 32740 16710 26580 30010 32720 16900 26950 30390 33150 16790 36660 41390 45140 16880 36960 41720 45503 17030 37470 42290 46130 19390 43040 48570 52990 19390 43040 48570 52990 FXmax[N] 3160 3130 3140 3150 4380 4360 4360 4370 7100 7090 7080 7090 7090 7340 7330 7330 7360 9320 9330 9320 6350 9690 9680 9690 6280 10170 10160 10100 6200 14570 14580 14510 6080 14410 14210 14130 7470 14590 14530 14460 7110 14290 14210 14110 6570 13850 13660 13510 8760 18600 17980 18180 8760 18600 17980 18180
180 ML_
200 ML_
225 SM_
250 SM_
280 SM_
315 SM_
315 ML_
315 LK_
355 SM_
355 ML_
355 LK_
400 L_
400 LK_
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 169
FAD
FAZ
71 80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_
FAZ N 215 315 320 430 425 800 1440 1470 2040 2240 2100 2870 2780 2730 5460 5370 5240 5810 5810
FAZ N 330 470 425 765 760 1150 2010 2130 2920 3230 3310 4140 5170 5080 9560 9440 9260 10250 10250
M000022
FAZ N 410 595 605 1015 1010 1435 2440 2630 3560 3940 4160 5040 6210 6100 10860 10680 10480 11510 11410
FAZ N 480 675 710 1215 1210 1645 2790 3040 4100 4540 4900 5840 7180 7070 12090 11900 11610 12630 12630
FAZ
M000023
FAD
Mounting arrangement IM V1
Motor size 40,000 hours 2-pole FAD N 530 690 775 1010 1020 150 2440 3120 3960 4570 6240 6440 6950 7280 5330 5860 6600 8010 8010 4-pole FAD N 650 865 1020 1375 1390 2010 3160 3980 5030 5770 7720 8170 9820 10300 11110 11810 12850 13680 13680 6-pole FAD N 745 980 1095 1620 1640 2210 3590 4490 5820 6660 8930 9580 11760 12330 13720 14718 15800 16610 17180 8-pole FAD N 815 1070 1185 1825 1840 2460 3950 4890 6370 7280 9690 10380 12740 13310 14980 15970 17500 18480 18480
71 80 90 100 112 132 160 180 200 225 250 280 SM_ 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_
1)
FAZ N 200 290 280 355 350 705 1180 1100 1590 1650 1380 1780 1270 940 2890 2360 1630 730 730
FAZ N 320 430 375 675 665 980 1650 1630 2340 2500 2410 2760 3350 2870 5820 5130 4080 3650 3650
FAZ N 390 550 550 925 915 1315 2090 2130 2890 3100 3047 3340 3810 3240 6270 5280 4190 3840 3270
FAZ N 455 645 660 1125 1110 1505 2430 2550 3430 3700 3780 4150 4780 4210 7530 6540 5000 4530 4530
On request
170 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Aluminum motors Permissible radial forces according to L10 principle Motor sizes 71 to 132
Motor size No. of poles Length of shaft extention E (mm) 71 80 90 100 112 M 2-8 2-8 2-8 2-8 2 4 6 8 2 4 6 8 2 2 2 4 4 4 6 6 6 6 8 8 8 30 40 50 60 60 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 Ball bearings Basic design with deep groove ball bearings 25,000 hours FXmax (N) FX0 (N) 680 930 1010 2280 1800 1790 1910 1940 1820 1770 1880 1930 3020 3020 3030 3120 3080 3050 3280 3240 3200 3010 3370 3310 3280 570 750 810 1800 1420 1410 1510 1530 1470 1430 1520 1560 2360 2360 2430 2440 2410 2440 2560 2530 2500 2510 2630 2590 2630 40,000 hours FX0 (N) FXmax (N) 680 930 1010 2280 1620 1590 1700 1720 1640 1560 1650 1690 2740 2730 2750 2790 2750 2710 2910 2880 2840 2660 2980 2940 2910 570 750 810 1800 1280 1250 1340 1360 1330 1260 1340 1370 2140 2130 2200 2180 2150 2170 2270 2250 2220 2220 2330 2300 2330
Alternative design with 63-series bearings 25,000 hours 40,000 hours FX0 (N) FXmax (N) FX0 (N) FXmax (N)
112 MB
132 SA 132 SB 132 SC 132 S 132 M 132 MB 132 S 132 MA 132 MB 132 MC 132 S 132 M 132 MB
2160 2160 2160 2160 2100 2100 2100 1700 4070 4060 3990 4090 4100 3990 4100 4100 4100 3840 4100 4100 3990
1700 1700 1700 1700 1700 1700 1700 2100 3180 3170 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200 3200
2160 2160 2160 2160 2100 2100 2100 1700 3670 3670 3690 3830 3780 3740 3990 3970 3930 3700 4100 4060 3990
1700 1700 1700 1700 1700 1700 1700 2100 2870 2870 2960 2990 2950 3000 3120 3100 3070 3090 3200 3170 3200
40,000 hours FX0(N) 4100 4380 4360 5320 5280 1) 4020 5280 5880 6760 2) 7180 7600 8940 7360 3) 7200 9360 10340 9080 4) 9380 10700 12540 5680 6640 7360 7460
FXmax(N) 3320 3545 3540 4300 4305 1) 3300 4380 4800 5640 2) 5980 6340 7400 6200 3) 5820 7560 8360 7360 4) 7600 8680 10160 4600 5380 5960 6060
180
200
225
250
280
1) 2) 3) 4)
The maximum lifetime of the grease is 38,000 h The maximum lifetime of the grease is 27,000 h The maximum lifetime of the grease is 23,000 h The maximum lifetime of the grease is 16,000 h
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 171
Permissible axial forces according to L10 principle The following tables give the permissible axial forces in Newton, assuming zero radial force. The values are based on normal conditions at 50 Hz with standard bearings and calculated bearing lives of 20,000 and 40,000 hours. At 60 Hz the values are to be reduced by 10 %. For two-speed motors, the values are to be based on the higher speed. The permissible loads of simultaneous radial and axial forces will be supplied on request. Given axial forces FAD, assumes D-bearing locked by means of locking ring. Without locking ring the FAD forces should be reduced to 70 % of list value.
M000022
FAD
Aluminum motors, motor sizes 71 to 280 Mounting arrangement IM B3
Motor size 20,000 hours 2-pole FAZ FAD N N 625 325 810 470 885 1620 1615 1770 1760 1760 2220 2220 2210 4160 5480 5000 5000 6000 4) 5260 485 1120 1115 1170 1160 1160 1620 1620 1610 4160 5480 6880 7380 9020 4) 5260 4-pole FAD N 780 1015 1170 2065 2060 2245 2245 2235 2840 2830 4740 4360 5000 5000 6000 6500 6-pole FAD N 890 1170 1270 2390 2385 2595 2580 2600 4840 5980 5000 5000 6000 7500 8-pole FAD N 985 1300 1410 2660 2655 2655 2875 2885 5980 6000 5000 5000 6000 7740
FAZ
71 80 90 100 112 M 112 MB 132 M 132 MA 132 MC 132 MBA 132 S 132 SA 132 SB 132 SBB 132 SC 132 SMA 132 SMB 132 SMC 132 SMD 132 SME 160 180 200 225 250 280
1) 2) 3) 4)
FAZ N 480 675 650 1565 1560 1645 1645 1635 2240 2200 4740 4360 7660 7600 9800 6500
FAZ N 590 830 870 1890 1885 1995 1980 2000 4840 5980 8300 10140 11520 7500
FAZ N 685 960 1010 2160 2155 2155 2270 2285 5980 6620 9880 11420 13700 7740
40,000 hours 2-pole FAD FAZ N N 515 215 650 315 720 1280 1275 1400 1395 1395 1740 1740 1730 3425 4600 1) 5000 2) 5000 3) 6000 4) 4220 320 780 775 800 795 795 1140 1140 1130 3425 4600 1) 5700 2) 6120 3) 7500 4) 4220
4-pole FAD N 630 810 945 1615 1610 1760 1760 1750 2205 2230 3920 3540 5000 5000 6000 5160
FAZ N 330 470 425 1115 1110 1160 1160 1150 1605 1595 3920 3540 6340 6220 8040 5160
6-pole FAD N 710 925 1005 1860 1860 2025 2010 2030 4000 4940 5000 5000 6000 6040
FAZ N 410 595 605 1360 1360 1425 1410 1435 4000 4940 6880 8420 9520 6040
8-pole FAD N 780 1015 1110 2065 2060 2060 2240 2245 4920 5460 5000 5000 6000 6180
FAZ N 480 675 710 1565 1560 1560 1640 1645 4920 5460 8160 9460 11380 6180
The maximum lifetime of the grease is 38,000 h The maximum lifetime of the grease is 27,000 h The maximum lifetime of the grease is 23,000 h The maximum lifetime of the grease is 16,000 h
172 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
FAZ
M000023
FAD
Aluminum motors, motor sizes 71 to 280 Mounting arrangement IM V1
Motor size 20,000 hours 2-pole FAZ FAD N N 640 315 845 450 945 450 1710 1060 1725 1040 1910 1075 1950 1050 1945 1045 2435 1480 2445 1470 2490 1425 4560 3810 5920 5115 5000 6350 5000 6770 6000 4) 8335 4) 6400 4400 4-pole FAD N 800 1075 1245 2180 2210 2460 2460 2495 3150 3195 5260 5080 5000 5000 6000 7920 6-pole FAD N 925 1225 1360 2510 2540 2815 2885 2780 5400 6000 5000 5000 6000 8500 8-pole FAD N 1020 1350 1485 2780 2790 2810 3130 3100 6560 6000 5000 5000 6000 8500
71 80 90 100 112 M 112 MB 132 M 132 MA 132 MC 132 MBA 132 S 132 SA 132 SB 132 SBB 132 SC 132 SMA 132 SMB 132 SMC 132 SMD 132 SME 160 180 200 225 250 280
1) 2) 3) 4)
FAZ N 470 640 600 1485 1460 1505 1505 1465 2035 1995 4310 3860 6950 6795 8820 5400
FAZ N 570 795 815 1815 1785 1850 1780 1885 4420 5445 7505 9270 10275 6180
FAZ N 665 925 960 2080 2070 2055 2115 2145 5580 6120 9215 10595 12645 6435
40,000 hours 2-pole FAD FAZ N N 530 200 690 290 775 280 1370 715 1385 700 1540 705 1580 670 1575 670 1950 995 1960 985 2005 940 3860 3110 5060 1) 4255 1) 5000 2) 5230 2) 5000 3) 5490 3) 6000 4) 6755 4) 5420 3420
4-pole FAD N 650 865 1020 1735 1110 1970 1970 2010 2515 2560 4440 4240 5000 5000 6000 6640
FAZ N 320 430 375 1035 1010 1015 1015 980 1400 1355 3490 3020 5650 5475 7120 4120
6-pole FAD N 745 980 1095 1980 2010 2245 2315 2210 4540 5600 5000 5000 6000 7840
FAZ N 390 550 550 1285 1260 1280 1210 1315 3560 4385 6025 7490 8235 4640
8-pole FAD N 815 1070 1185 2185 2195 2210 2490 2460 5460 6000 5000 5000 6000 7980
FAZ N 455 645 660 1485 1475 1460 1470 1505 4480 4900 7435 8535 10205 4775
The maximum lifetime of the grease is 38,000 h. The maximum lifetime of the grease is 27,000 h. The maximum lifetime of the grease is 23,000 h. The maximum lifetime of the grease is 16,000 h.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 173
Rating plates
The rating plates are in table form giving values for speed, current and power factor for three voltages for cast iron motors: 400V-415V-690V as standard. For aluminum motors there are one or two voltages in use; 230V-400V depending on the frame size. Other voltage and frequency combinations are possible and can be ordered with variant codes 002 or 209. Please see Variant code section. The following information will be shown on the motor rating plate: Lowest nominal efficiency at 100 %, 75 % and 50 % rated load Efficiency level Year of manufacture Type of protection Apparatus group Temperature class Identification number of the certification body Certificate number : for cast iron motors both ATEX and IECEx are stamped on the rating plate as standard. For aluminum motors self certification.
M000736a
M000702
174 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000762a
M000761a
M000737a
5 6 7 8 9 10 11 12 13 14
E Voltage and frequency code F Generation code G Variant codes
Position 14
Generation code G, H... The product code must be, if needed, followed by variant codes.
Position 12 Mounting arrangement A = Foot-mounted, top-mounted terminal box R = Foot-mounted, terminal box RHS seen from D-end
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 175
Dust ignition protection cast iron motors Technical data for Ex t IIIB/IIIC T125 C Db/Dc, IP 65/IP 55
IE2
IP 65 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Current Is IN Torque TN Nm Tl TN Tb TN Moment of inertia J = 1/4 GD2 kgm2 Weight kg Sound pressure level LPA dB
Output kW Motor type 3000 r/min = 2-poles 0.37 M3GP 71 MA 0.55 M3GP 71 MB 0.75 M3GP 80 MB 1.1 M3GP 80 MC 1.5 M3GP 90 SLB 2.2 M3GP 90 SLC 3 M3GP 100 LB 4 M3GP 112 MB 5.5 M3GP 132 SMB 7.5 M3GP 132 SMC 11 M3GP 160 MLA 15 M3GP 160 MLB 18.5 M3GP 160 MLC 22 M3GP 180 MLA 30 M3GP 200 MLA 37 M3GP 200 MLC 45 M3GP 225 SMB 55 M3GP 250 SMA 75 M3GP 280 SMA 90 M3GP 280 SMB 110 M3GP 315 SMA 132 M3GP 315 SMB 160 M3GP 315 SMC 200 M3GP 315 MLA 3) M3GP 355 SMA 250 3) M3GP 355 SMB 315 3) M3GP 355 SMC 355 3) M3GP 355 MLA 400 3) M3GP 355 MLB 450 3) M3GP 355 LKA 500 3) M3GP 355 LKB 560 4) M3GP 400 LA 560 4) 560 M3GP 400 LKA 4) M3GP 400 LB 630 4) M3GP 400 LKB 630 4) M3GP 400 LC 710 4) 710 M3GP 400 LKC 3000 r/min = 2-poles 2) 22 M3GP 160 MLD 30 M3GP 180 MLB 37 M3GP 180 MLC 5) M3GP 200 MLE 45 55 M3GP 225 SMC 5) M3GP 225 SMD 67 75 M3GP 250 SMB 1) 2) 5) M3GP 250 SMC 90 110 M3GP 280 SMC
1) 2) 3)
Product code
400 V 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 400 V 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP
50 Hz 071 321-B 071 322-B 081 322-B 081 323-B 091 322-B 091 323-B 101 322-B 111 322-B 131 322-B 131 324-B 161 410-H 161 420-H 161 430-H 181 410-H 201 410-G 201 430-G 221 220-G 251 210-G 281 210-G 281 220-G 311 210-G 311 220-G 311 230-G 311 410-G 351 210-G 351 220-G 351 230-G 351 410-G 351 420-G 351 810-G 351 820-G 401 510-G 401 810-G 401 520-G 401 820-G 401 530-G 401 830-G 50 Hz 161 440-H 181 420-H 181 430-H 201 450-G 221 230-G 221 240-G 251 220-G 251 230-G 281 230-G
2768 2813 2895 2870 2900 2885 2925 2895 2865 2890 2931 2929 2934 2938 2956 2954 2968 2975 2978 2976 2982 2982 2981 2980 2984 2980 2984 2982 2983 2982 2983 2988 2988 2987 2987 2987 2987 2929 2943 2947 2944 2965 2966 2969 2965 2978
74.8 77.8 80.6 81.8 82.2 84.7 85.2 86.1 88.0 88.6 90.1 91.2 91.8 91.7 93.2 93.6 93.9 94.3 94.3 94.6 94.9 95.1 95.4 95.7 95.7 95.7 95.7 96.9 97.1 96.9 97.0 97.2 97.2 97.4 97.4 97.5 97.5 91.2 92.5 92.8 93.3 93.9 93.9 94.0 94.0 95.1
74.7 78.3 79.9 82.4 84.1 86.7 84.9 87.0 88.6 88.8 90.5 91.9 92.2 92.2 93.6 94.0 93.8 94.1 94.1 94.5 94.4 94.8 95.2 95.7 95.5 95.7 95.7 96.6 97.0 96.9 97.0 97.2 97.2 97.4 97.4 97.4 97.4 91.6 93.0 93.0 93.6 93.9 93.7 94.0 94.2 95.0
71.0 76.0 76.2 80.2 82.7 85.7 82.8 86.6 88.0 87.5 89.6 91.4 91.8 91.7 93.0 93.4 92.9 93.0 92.8 93.5 92.9 93.6 94.2 94.9 94.5 95.1 95.2 95.9 96.4 96.5 96.5 96.6 96.6 96.9 96.9 97.0 97.0 91.0 92.6 92.5 93.0 92.9 92.6 93.2 93.7 94.2
0.78 0.79 0.74 0.80 0.86 0.87 0.86 0.86 0.86 0.84 0.89 0.89 0.90 0.90 0.88 0.89 0.87 0.89 0.88 0.90 0.86 0.88 0.89 0.90 0.89 0.89 0.88 0.88 0.90 0.90 0.90 0.89 0.89 0.89 0.89 0.89 0.89 0.90 0.90 0.90 0.88 0.88 0.86 0.89 0.90 0.90
CENELEC-design 0.91 4.5 1.27 2.2 1.29 5.6 1.86 2.4 1.81 7.7 2.4 4.2 2.4 7.5 3.6 2.7 3 7.5 4.9 2.5 4.3 6.8 7.2 1.9 5.9 9.1 9.7 3.1 7.7 8.1 13.1 2.9 10.4 7.0 18.3 2.0 14.5 7.3 24.7 2.0 19.7 7.2 35.8 2.6 26.6 7.2 48.9 3.0 32.3 7.5 60.2 2.8 38.4 7.0 71.5 2.5 52.7 7.4 96.9 3.0 64.1 7.5 119 2.8 79.5 7.2 144 2.7 94.5 7.8 176 2.4 130 7.6 240 2.1 152 7.4 288 2.1 194 7.6 352 2.0 227 7.4 422 2.2 271 7.5 512 2.3 335 7.7 640 2.6 423 7.7 800 2.1 533 7.0 1009 2.1 608 7.2 1136 2.2 677 7.1 1280 2.3 743 7.9 1440 2.2 827 7.5 1601 2.0 925 8.0 1792 2.2 934 7.8 1789 2.1 934 7.8 1789 2.1 1048 7.8 2014 2.2 1048 7.8 2014 2.2 1180 7.8 2269 2.6 1180 7.8 2269 2.6 High-output design 38.6 7.3 71.7 2.7 52 6.8 97.3 2.3 63.9 7.9 119 2.9 79.1 7.3 145 2.9 96 7.1 177 2.6 119 7.4 215 2.8 129 7.9 241 2.6 153 7.7 289 2.6 185 7.9 352 2.4
2.3 2.5 4.2 3.5 2.6 2.5 3.5 3.2 2.7 3.6 3.1 3.5 3.4 3.1 3.2 3.2 3.0 3.1 3.0 2.9 3.0 3.0 3.0 3.0 3.3 3.0 3.0 2.9 2.9 3.9 4.1 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.1 3.6 3.1 3.0 3.2 3.2 3.1 3.0
0.00039 0.00051 0.001 0.0012 0.00254 0.0028 0.00528 0.00575 0.01275 0.01359 0.043 0.052 0.062 0.089 0.15 0.19 0.26 0.49 0.8 0.9 1.2 1.4 1.7 2.1 3 3.4 3.6 4.1 4.3 4.8 5.2 7.9 7.9 8.2 8.2 9.3 9.3 0.07 0.13 0.13 0.22 0.29 0.31 0.57 0.59 1.15
11 11 16 18 24 25 36 37 68 70 207 216 227 259 275 305 365 425 625 665 880 940 1025 1190 1600 1680 1750 2000 2080 2320 2460 2950 2950 3050 3050 3300 3300 233 292 292 310 385 395 465 475 725
58 56 57 60 69 64 68 70 70 70 71 71 69 69 74 75 76 75 77 77 78 78 78 78 83 83 83 83 83 83 83 82 82 82 82 82 82 77 78 77 79 80 78 80 80 77
Temperature rise class F Efciency class IE1 3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
Equipment protection level and equipment group subdivision must be selected when ordering by selecting appropriate variant code; 334 Ex t, dust group IIIB T125 Db (non-conductive dust) acc. to IEC/EN60079-31 335 Ex t, dust group IIIB T125 Dc (non-conductive dust) acc. to IEC/EN60079-31 336 Ex t, dust group IIIC T125 Db (conductive dust) acc. to IEC/EN60079-31 337 Ex t, dust group IIIC T125 Dc (conductive dust) acc. to IEC/EN60079-31
4)
Unidirectional fan construction as standard. Direction of rotation must be stated when ordering, see variant codes 044 and 045 For 400-450 V 50 Hz (380 V 50 Hz voltage code B)
5)
176 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition protection cast iron motors Technical data for Ex t IIIB/IIIC T125 C Db/Dc, IP 65/IP 55
IE2
IP 65 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Current Is IN Torque TN Nm Tl TN Tb TN Moment of inertia J = 1/4 GD2 kgm2 Weight kg Sound pressure level LPA dB
Output kW Motor type 1500 r/min = 4-poles 0.25 M3GP 71 MA 0.37 M3GP 71 MB 0.55 M3GP 80 MA 0.75 M3GP 80 MD 1.1 M3GP 90 SLB 1.5 M3GP 90 SLD 2.2 M3GP 100 LC 3 M3GP 100 LD 4 M3GP 112 MB 5.5 M3GP 132 SMB 7.5 M3GP 132 SMC 11 M3GP 160 MLC 15 M3GP 160 MLE 18.5 M3GP 180 MLA 22 M3GP 180 MLB 30 M3GP 200 MLB 37 M3GP 225 SMB 45 M3GP 225 SMC 55 M3GP 250 SMA 75 M3GP 280 SMA 90 M3GP 280 SMB 110 M3GP 315 SMA 132 M3GP 315 SMB 160 M3GP 315 SMC 200 M3GP 315 MLA 250 M3GP 355 SMA 315 M3GP 355 SMB 3) M3GP 355 SMC 350 3) M3GP 355 MLA 400 3) M3GP 355 MLB 450 500 M3GP 355 LKA 3) M3GP 400 LA 560 3) M3GP 400 LKA 560 3) M3GP 400 LB 630 3) M3GP 400 LKB 630 3) 680 M3GP 400 LC 3) M3GP 400 LKC 680 1500 r/min = 4-poles 18.5 M3GP 160 MLF 2) 22 M3GP 160 MLG 1) 2) M3GP 180 MLC 30 37 M3GP 200 MLC 55 M3GP 225 SMD 2) 3) M3GP 225 SME 60 3) M3GP 250 SMB 75 2) 3) M3GP 250 SMC 86 110 M3GP 280 SMC
1) 2) 3)
Product code
400 V 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 400 V 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP
50 Hz 072 321-B 072 322-B 082 321-B 082 324-B 092 322-B 092 325-B 102 323-B 102 324-B 112 322-B 132 322-B 132 323-B 162 430-H 162 450-H 182 410-H 182 420-H 202 420-G 222 220-G 222 230-G 252 210-G 282 210-G 282 220-G 312 210-G 312 220-G 312 230-G 312 410-G 352 210-G 352 220-G 352 230-G 352 410-G 352 420-G 352 810-G 402 510-G 402 810-G 402 520-G 402 820-G 402 530-G 402 830-G 50 Hz 162 460-H 162 470-H 182 430-H 202 430-G 222 240-G 222 250-G 252 220-G 252 230-G 282 230-G
1365 1380 1415 1430 1435 1430 1450 1450 1440 1460 1450 1470 1467 1474 1471 1475 1480 1477 1479 1484 1483 1487 1487 1487 1486 1488 1488 1487 1489 1490 1490 1491 1491 1491 1491 1492 1492 1469 1466 1473 1475 1483 1479 1476 1477 1485
68.3 72.4 74.5 81.0 83.6 84.3 85.9 86.8 86.8 89.0 89.3 91.2 92.0 91.6 91.6 93.6 93.6 94.1 94.3 94.5 94.7 95.1 95.4 95.6 95.6 95.9 95.9 95.9 96.3 96.8 97.0 96.8 96.8 97.0 97.0 97.1 97.1 91.7 90.8 92.2 93.0 94.3 93.6 94.3 94.1 95.1
70.8 74.5 73.8 80.7 84.5 85.6 85.1 87.0 87.7 89.8 90.1 91.5 92.4 92.0 92.4 94.0 93.9 94.6 94.3 94.5 94.8 95.1 95.4 95.6 95.6 95.9 95.9 95.9 96.3 96.8 97.0 96.8 96.8 97.0 97.0 97.1 97.1 92.1 91.1 92.3 93.1 94.5 93.7 94.5 94.4 95.2
69.7 74.6 70.0 77.3 83.2 84.7 83.4 85.4 87.3 88.9 90.0 90.6 92.1 91.2 92.2 93.7 93.4 94.4 93.6 93.9 94.4 94.3 94.7 95.1 95.3 95.5 95.6 95.7 95.9 96.3 96.5 96.3 96.3 96.5 96.5 96.6 96.6 91.4 90.4 91.6 92.3 93.9 92.9 94.2 94.0 94.7
0.81 0.83 0.73 0.73 0.80 0.83 0.78 0.79 0.81 0.80 0.81 0.82 0.84 0.83 0.83 0.85 0.85 0.88 0.84 0.85 0.86 0.86 0.86 0.85 0.86 0.86 0.86 0.86 0.85 0.86 0.86 0.85 0.85 0.87 0.87 0.85 0.85 0.83 0.81 0.81 0.82 0.83 0.84 0.86 0.85 0.86
CENELEC-design 0.65 3.5 1.74 1.9 0.88 4.0 2.5 1.6 1.45 5.0 3.7 2.0 1.83 5.3 5 2.7 2.3 6.1 7.3 2.7 3 6.3 10 2.7 4.7 6.4 14.4 2.9 6.3 7.7 19.7 2.9 8.2 7.0 26.5 2.5 11.1 5.9 35.9 1.7 14.9 5.6 49.3 1.6 21.2 7.8 71.4 3.0 28 7.8 97.6 3.0 35.1 7.2 119 2.6 41.7 6.8 142 2.5 54.4 7.4 194 3.0 67.1 7.6 238 3.2 78.4 7.6 290 3.2 100 7.2 355 2.5 134 6.9 482 2.5 159 7.2 579 2.5 194 7.2 706 2.0 232 7.1 847 2.3 284 7.2 1027 2.4 351 7.2 1285 2.5 437 7.1 1604 2.3 551 7.3 2021 2.3 612 6.9 2247 2.4 705 6.8 2565 2.3 780 6.9 2884 2.3 865 6.8 3204 2.0 982 7.4 3586 2.4 982 7.4 3586 2.4 1077 7.6 4034 2.2 1077 7.6 4034 2.2 1189 7.9 4352 2.5 1189 7.9 4352 2.5 High-output design 35 7.8 120 3.2 43.1 7.9 143 3.3 57.9 7.1 194 2.8 70 7.5 239 3.5 101 7.4 354 3.4 110 8.0 387 3.6 133 7.6 485 2.8 155 7.8 556 2.9 194 7.6 707 3.0
2.0 2.1 2.8 3.2 3.4 3.4 3.6 3.4 2.9 2.4 2.4 3.5 3.4 3.1 3.0 2.8 2.9 2.7 3.1 2.8 2.7 2.5 2.7 2.9 2.9 2.7 2.8 2.7 2.6 2.9 3.0 2.8 2.8 2.9 2.9 3.1 3.1 3.5 3.6 3.2 3.2 2.9 3.0 3.2 3.5 3.0
0.00074 0.00088 0.00144 0.00205 0.0044 0.0053 0.00948 0.011 0.0125 0.03282 0.03659 0.096 0.13 0.19 0.21 0.34 0.42 0.49 0.72 1.25 1.5 2.3 2.6 2.9 3.5 5.9 6.9 7.2 8.4 8.4 10 15 15 16 16 17 17 0.13 0.13 0.248 0.34 0.55 0.55 0.88 0.98 1.85
10 11 15 17 25 27 36 38 44 70 73 226 249 271 279 305 355 390 415 625 665 900 960 1000 1160 1610 1780 1820 2140 2140 2500 3200 3200 3300 3300 3400 3400 249 249 298 305 410 410 470 495 725
45 45 45 50 50 56 56 58 59 67 64 62 61 62 62 61 67 67 66 68 68 70 70 70 74 74 74 78 78 78 78 78 78 78 78 78 78 68 68 66 73 68 74 73 74 68
Temperature rise class F Efciency class IE1 3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
Equipment protection level and equipment group subdivision must be selected when ordering by selecting appropriate variant code; 334 Ex t, dust group IIIB T125 Db (non-conductive dust) acc. to IEC/EN60079-31 335 Ex t, dust group IIIB T125 Dc (non-conductive dust) acc. to IEC/EN60079-31 336 Ex t, dust group IIIC T125 Db (conductive dust) acc. to IEC/EN60079-31 337 Ex t, dust group IIIC T125 Dc (conductive dust) acc. to IEC/EN60079-31
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 177
Dust ignition protection cast iron motors Technical data for Ex t IIIB/IIIC T125 C Db/Dc, IP 65/IP 55
IE2
IP 65 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Current Is IN Torque TN Nm Tl TN Tb TN Moment of inertia J = 1/4 GD2 kgm2 Weight kg Sound pressure level LPA dB
Output kW Motor type 1000 r/min = 6-poles 0.18 M3GP 71 MA 0.25 M3GP 71 MB 0.37 M3GP 80 MA 0.55 M3GP 80 MB 0.75 M3GP 90 SLC 1.1 M3GP 90 SLE 1.5 M3GP 100 L 2.2 M3GP 112 MB 3 M3GP 132 SMB 4 M3GP 132 SMB 5.5 M3GP 132 SMF 11 M3GP 160 MLB 15 M3GP 180 MLB 18.5 M3GP 200 MLA 22 M3GP 200 MLB 30 M3GP 225 SMB 37 M3GP 250 SMA 45 M3GP 280 SMA 55 M3GP 280 SMB 75 M3GP 315 SMA 90 M3GP 315 SMB 110 M3GP 315 SMC 132 M3GP 315 MLA 160 M3GP 355 SMA 200 M3GP 355 SMB 250 M3GP 355 SMC 315 M3GP 355 MLB 355 M3GP 355 LKA 400 M3GP 400 LA 400 M3GP 400 LKA 450 M3GP 400 LB 450 M3GP 400 LKB 500 M3GP 400 LC 500 M3GP 400 LKC 560 M3GP 400 LD 560 M3GP 400 LKD 1) M3GP 450 LC 800 1000 r/min = 6-poles 1) 2) 14 M3GP 160 MLC 2) 18.5 M3GP 180 MLC 2) M3GP 200 MLC 30 2) M3GP 225 SMC 37 45 M3GP 250 SMB 75 M3GP 280 SMC
1) 2)
Product code
400 V 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 400 V 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP
50 Hz 073 321-B 073 322-B 083 321-B 083 322-B 093 323-B 093 324-B 103 322-B 113 322-B 133 321-B 133 322-B 133 324-B 163 420-H 183 420-H 203 410-G 203 420-G 223 220-G 253 210-G 283 210-G 283 220-G 313 210-G 313 220-G 313 230-G 313 410-G 353 210-G 353 220-G 353 230-G 353 420-G 353 810-G 403 510-G 403 810-G 403 520-G 403 820-G 403 530-G 403 830-G 403 540-G 403 840-G 453 530-G 50 Hz 163 430-H 183 430-H 203 430-G 223 230-G 253 220-G 283 230-G
900 895 915 920 960 930 950 950 975 960 965 972 972 983 983 985 987 990 990 992 992 991 991 993 993 993 992 993 993 993 994 994 993 993 993 993 995 969 975 983 983 986 990
63.7 67.2 71.0 73.9 78.7 78.2 82.2 82.5 85.3 84.9 86.1 90.1 90.4 90.9 91.6 92.2 93.1 93.4 93.8 94.4 94.8 95.0 95.3 95.4 95.7 95.7 95.7 95.7 96.2 96.2 96.6 96.6 96.6 96.6 96.9 96.9 96.9 89.2 90.1 90.8 92.1 93.1 94.2
63.8 67.2 71.1 75.0 77.3 78.6 82.9 83.8 84.5 85.3 86.6 90.8 91.0 91.1 91.9 92.6 93.4 93.6 94.0 94.4 94.8 95.0 95.4 95.4 95.7 95.7 95.7 95.7 96.3 96.3 96.6 96.6 96.7 96.7 96.9 96.9 97.0 89.4 90.2 91.2 92.5 93.3 94.5
59.0 62.6 67.0 72.8 72.5 76.4 81.6 81.7 81.3 83.9 85.5 90.4 90.4 90.3 91.0 92.2 92.8 93.1 93.3 93.5 94.2 94.6 94.9 94.8 95.1 95.1 95.2 95.1 95.8 95.8 96.1 96.1 96.2 96.2 96.4 96.4 96.6 88.0 88.7 90.2 92.1 92.6 94.1
0.71 0.69 0.69 0.71 0.58 0.66 0.69 0.69 0.63 0.68 0.71 0.81 0.82 0.82 0.82 0.82 0.81 0.84 0.84 0.82 0.84 0.83 0.83 0.83 0.84 0.83 0.83 0.83 0.82 0.82 0.82 0.82 0.83 0.83 0.85 0.85 0.84 0.75 0.74 0.81 0.83 0.82 0.84
CENELEC-design 0.57 3.1 1.9 2.0 0.77 3.4 2.6 2.2 1.09 3.6 3.8 1.8 1.51 3.8 5.7 1.8 2.3 4.5 7.4 2.3 3 4.0 11.2 1.9 3.8 4.0 15 1.5 5.5 4.4 22.1 1.7 8 5.5 29.3 1.8 10 4.6 39.7 1.5 12.9 5.1 54.4 2.0 21.7 7.8 108 2.3 29.2 7.2 147 1.9 35.8 7.1 179 3.2 42.2 7.5 213 3.2 57.2 7.4 290 3.4 70.8 7.2 357 3.2 82.7 7.0 434 2.5 100 7.0 530 2.7 139 7.4 721 2.4 163 7.5 866 2.4 201 7.4 1059 2.5 240 7.5 1271 2.7 291 7.0 1538 2.0 359 7.2 1923 2.2 454 7.4 2404 2.6 572 7.0 3032 2.5 645 6.8 3413 2.3 731 7.1 3846 2.3 731 7.1 3846 2.3 819 7.4 4323 2.4 819 7.4 4323 2.4 900 7.2 4808 2.5 900 7.2 4808 2.5 981 7.4 5385 2.4 981 7.4 5385 2.4 1418 7.2 7677 1.3 High-output design 30.2 7.9 137 2.8 40 7.2 181 2.0 58.8 7.5 291 3.5 69.8 7.1 359 3.0 85 7.2 435 3.3 136 7.3 723 2.8
2.1 2.3 2.2 2.2 3.1 2.3 1.1 2.3 2.9 2.2 2.3 3.5 3.2 3.1 3.2 3.0 2.9 2.5 2.6 2.8 2.8 2.9 3.0 2.6 2.7 2.9 2.7 2.7 2.7 2.7 2.8 2.8 2.7 2.7 2.8 2.8 2.7 3.9 3.2 3.4 2.8 2.8 2.7
0.00089 0.0011 0.00187 0.00239 0.00491 0.0054 0.00873 0.0125 0.03336 0.03336 0.0487 0.126 0.25 0.37 0.43 0.64 1.16 1.85 2.2 3.2 4.1 4.9 5.8 7.9 9.7 11.3 13.5 15.5 17 17 20.5 20.5 22 22 24 24 41 0.126 0.25 0.49 0.75 1.49 2.85
10 12 15 17 25 28 37 44 69 69 86 247 298 265 285 350 420 605 645 830 930 1000 1150 1520 1680 1820 2180 2500 2900 2900 3150 3150 3300 3300 3400 3400 4800 247 298 305 380 465 725
42 42 47 47 44 44 49 66 57 57 57 65 58 66 61 61 66 66 66 70 70 70 68 75 75 75 75 78 76 76 76 76 76 76 77 77 81 64 61 65 64 65 66
Equipment protection level and equipment group subdivision must be selected when ordering by selecting appropriate variant code; 334 Ex t, dust group IIIB T125 Db (non-conductive dust) acc. to IEC/EN60079-31 335 Ex t, dust group IIIB T125 Dc (non-conductive dust) acc. to IEC/EN60079-31 336 Ex t, dust group IIIC T125 Db (conductive dust) acc. to IEC/EN60079-31 337 Ex t, dust group IIIC T125 Dc (conductive dust) acc. to IEC/EN60079-31
178 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition protection cast iron motors Technical data for Ex t IIIB/IIIC T125 C Db/Dc, IP 65/IP 55
Output kW Motor type 750 r/min = 8-poles 0.09 M3GP 71 MA 0.12 M3GP 71 MB 0.18 M3GP 80 MA 0.25 M3GP 80 MB 0.37 M3GP 90 SLB 0.55 M3GP 90 SLC 0.75 M3GP 100 LA 1.1 M3GP 100 LB 1.5 M3GP 112 M 2.2 M3GP 132 SMA 3 M3GP 132 SMB 4 M3GP 160 MLA 5.5 M3GP 160 MLB 7.5 M3GP 160 MLC 11 M3GP 180 MLB 15 M3GP 200 MLA 18.5 M3GP 225 SMA 22 M3GP 225 SMB 30 M3GP 250 SMA 37 M3GP 280 SMA 45 M3GP 280 SMB 55 M3GP 315 SMA 75 M3GP 315 SMB 90 M3GP 315 SMC 110 M3GP 315 MLA 132 M3GP 355 SMA 160 M3GP 355 SMB 200 M3GP 355 SMC 250 M3GP 355 MLB 315 M3GP 400 LA 315 M3GP 400 LKA 355 M3GP 400 LB 355 M3GP 400 LKB 400 M3GP 400 LC 400 M3GP 400 LKC 750 r/min = 8-poles 18.5 M3GP 200 MLB 30 M3GP 225 SMC 37 M3GP 250 SMB 55 M3GP 280 SMC
Product code
400 V 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 3GGP 400 V 3GGP 3GGP 3GGP 3GGP
50 Hz 074 101-B 074 102-B 084 101-B 084 102-B 094 102-B 094 103-B 104 101-B 104 102-B 114 101-B 134 101-B 134 102-B 164 410-H 164 420-H 164 430-H 184 420-H 204 410-G 224 210-G 224 220-G 254 210-G 284 210-G 284 220-G 314 210-G 314 220-G 314 230-G 314 410-G 354 210-G 354 220-G 354 230-G 354 420-G 404 510-G 404 810-G 404 520-G 404 820-G 404 530-G 404 830-G 50 Hz 204 420-G 224 230-G 254 220-G 284 230-G
660 670 700 680 705 655 710 695 690 715 715 722 723 718 723 734 734 732 735 741 741 742 741 741 740 744 744 743 743 744 744 743 743 744 744 734 731 737 741
49.4 51.4 54.2 58.6 66.3 61.8 74.0 76.0 74.4 79.7 79.9 86.7 86.8 85.5 88.3 89.9 90.0 90.6 91.4 92.7 93.2 93.4 93.7 94.0 94.0 94.7 95.2 95.3 95.4 96.1 96.1 96.2 96.2 96.3 96.3 89.8 90.7 92.2 93.4
46.0 47.5 51.1 58.1 64.0 65.6 73.0 76.5 75.9 80.8 80.8 87.4 87.6 86.3 89.2 90.3 90.3 91.2 91.2 92.7 93.2 93.5 93.9 94.2 94.3 94.7 95.2 95.4 95.5 96.2 96.2 96.3 96.3 96.4 96.4 90.2 91.5 91.7 93.5
38.5 39.9 43.5 52.3 57.1 65.2 68.2 74.6 74.1 78.7 79.1 86.6 86.8 85.5 88.7 89.6 89.3 90.6 90.7 91.6 92.2 92.7 93.4 93.6 94.0 94.0 94.5 94.8 95.0 95.8 95.8 96.1 96.1 96.0 96.0 89.6 91.3 91.0 92.8
0.59 0.56 0.59 0.65 0.54 0.67 0.61 0.66 0.70 0.66 0.64 0.71 0.71 0.70 0.72 0.79 0.74 0.77 0.78 0.78 0.78 0.81 0.82 0.82 0.83 0.80 0.80 0.80 0.80 0.81 0.81 0.83 0.83 0.82 0.82 0.80 0.78 0.78 0.80
CENELEC-design 0.44 2.0 1.3 1.8 0.6 2.1 1.71 2.8 0.81 3.6 2.4 2.2 0.94 3.0 3.5 2.0 1.49 2.8 5 1.4 1.91 2.3 8 1.3 2.3 3.6 10 1.8 3.1 3.4 15.1 1.7 4.1 3.2 20.7 1.4 6 3.2 29.3 1.1 8.4 4.7 40 1.2 9.3 5.4 52.9 1.7 12.8 5.8 72.6 1.9 18 5.7 99.7 2.1 24.9 5.7 145 1.7 30.4 7.0 195 2.4 40 6.1 240 2.2 45.5 6.5 287 2.2 60.7 6.7 389 2.0 73.8 7.3 476 1.7 89.3 7.6 579 1.8 104 7.1 707 1.6 140 7.1 966 1.7 168 7.4 1159 1.8 203 7.3 1419 1.8 251 7.5 1694 1.5 303 7.6 2053 1.6 378 7.4 2570 1.6 472 7.5 3213 1.6 584 7.0 4043 1.2 584 7.0 4043 1.2 641 6.8 4562 1.2 641 6.8 4562 1.2 731 7.4 5134 1.3 731 7.4 5134 1.3 High-output design 37.1 6.9 240 2.2 61.2 6.3 391 2.3 74.2 7.5 479 2.3 106 7.9 708 1.9
2.0 2.4 2.5 1.9 2.2 1.5 2.5 2.2 1.9 1.7 1.8 2.8 3.1 3.1 2.7 3.2 3.0 2.9 2.9 3.0 3.1 2.7 2.7 2.7 2.7 2.6 2.6 2.6 2.7 2.6 2.6 2.5 2.5 2.7 2.7 3.2 3.0 3.4 3.1
0.00089 0.0011 0.00187 0.00239 0.00444 0.00491 0.0072 0.00871 0.0106 0.03336 0.04003 0.133 0.133 0.133 0.245 0.45 0.61 0.68 1.25 1.85 2.2 3.2 4.1 4.9 5.8 7.9 9.7 11.3 13.5 17 17 21 21 24 24 0.54 0.75 1.52 2.85
11 12 15 17 24 25 30 30 39 70 75 245 245 245 292 280 335 350 420 605 645 830 930 1000 1150 1520 1680 1820 2180 2900 2900 3200 3200 3400 3400 300 375 465 725
40 43 45 50 50 53 46 53 55 56 58 59 53 55 63 56 55 56 56 65 65 62 62 64 72 69 69 69 72 71 71 71 71 71 71 57 59 59 65
Equipment protection level and equipment group subdivision must be selected when ordering by selecting appropriate variant code; 334 Ex t, dust group IIIB T125 Db (non-conductive dust) acc. to IEC/EN60079-31 335 Ex t, dust group IIIB T125 Dc (non-conductive dust) acc. to IEC/EN60079-31 336 Ex t, dust group IIIC T125 Db (conductive dust) acc. to IEC/EN60079-31 337 Ex t, dust group IIIC T125 Dc (conductive dust) acc. to IEC/EN60079-31
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 179
Dust ignition protection aluminum motors Technical data for Category 2 D - T = 125 C - IP 65
IE2
IP 65 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Output kW 3000 1.5 2.2 3 4 5.5 7.5 3000 2.7 4 5.5 9.2 11 1500 1.1 1.5 2.2 3 4 5.5 7.5 1500 1.85 2.2 4 5.5 9.2 1000 0.75 1.1 1.5 2.2 3 4 5.5 1000 1.3 2.2 3
1) 2) 3)
Current
Torque Tb TN 3 2.8 3.2 2.8 3.2 3.4 3 3.6 3.4 3 3.4 2.6 3 2.6 3 2.6 2.6 2.7 2.4 2.4 2.8 3.1 2.8 2.4 2.1 2.3 2.8 2.3 2.5 2.4 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.0019 0.0024 0.0041 0.0061 0.014 0.016 0.0027 0.005 0.0062 0.018 0.018 0.0032 0.0043 0.0069 0.0082 0.01 0.031 0.038 0.0043 0.0048 0.009 0.0126 0.048 0.0032 0.0043 0.0082 0.01 0.031 0.038 0.045 13 16 21 26 38 43 18 25 30 52 52 13 16 21 24 29 42 49 16 17 25 34 59 13 16 23 28 39 46 54 18 26 32 63 63 65 67 75 73 68 68 68 68 68 50 50 64 66 60 66 66 50 50 60 64 59 44 44 49 54 57 61 57 44 49 76
Motor Product code 400 V 50 Hz 90 S 3GAA 091 001-E 90 L 3GAA 091 002-E 100 L 3GAA 101 001-E 112 M 3GAA 111 101-E 132SA 3GAA 131 001-E 132 SB 3GAA 131 002-E 400 V 50 Hz 90 LB 3GAA 091 003-E 100 LB 3GAA 101 002-E 112 MB 3GAA 111 102-E 132 SBB 3GAA 131 004-E 132 SC 3GAA 131 003-E 400 V 50 Hz 90 S 3GAA 092 001-E 90 L 3GAA 092 002-E 100 LA 3GAA 102 001-E 100 LB 3GAA 102 002-E 112 M 3GAA 112 101-E 132 S 3GAA 132 001-E 132 M 3GAA 132 002-E 400 V 50 Hz 90 L 3GAA 092 003-E 90 LB 3GAA 092 004-E 100 LC 3GAA 102 003-E 112 MB 3GAA 112 102-E 132 MBA 3GAA 132 004-E 400 V 50 Hz 90 S 3GAA 093 001-E 90 L 3GAA 093 002-E 100 L 3GAA 103 001-E 112 M 3GAA 113 101-E 132 S 3GAA 133 001-E 132 MA 3GAA 133 002-E 132 MB 3GAA 133 003-E 400 V 50 Hz 90 LB 3GAA 093 003-E 100 LC 3GAA 103 002-E 112 MB 3GAA 113 102-E
type r/min = 2-poles 2) M3AAD 3) M3AAD 3) M3AAD 2) M3AAD 2) M3AAD 2) M3AAD r/min = 2-poles 1) 2) M3AAD 1) 2) M3AAD 1) 2) M3AAD 1) 2) M3AAD 1) 2) M3AAD r/min = 4-poles 2) M3AAD 2) M3AAD 2) M3AAD 2) M3AAD 2) M3AAD 2) M3AAD 2) M3AAD r/min = 4-poles 1) M3AAD 1) M3AAD 1) M3AAD 1) M3AAD 3) M3AAD r/min = 6-poles 2) M3AAD 2) M3AAD 2) M3AAD 3) M3AAD 2) M3AAD 2) M3AAD 2) M3AAD r/min = 6-poles 1) 2) M3AAD 1) 2) M3AAD 1) 2) M3AAD
Full 3/4 Speed load load r/min 100% 75% 2895 2890 2905 2885 2845 2860 2860 2900 2850 2875 2890 1420 1420 1430 1430 1430 1450 1450 1390 1390 1420 1420 1455 925 915 950 960 960 965 960 910 940 920 78.5 83.6 85.4 85.7 85.8 87 81 84.3 86.4 87 88.7 77.2 81.3 82.3 84.6 86 86.5 88.6 79.3 80 83.2 85.1 89.8 71.5 72.9 79.6 82.8 82.5 83.6 83.8 74.4 78 79.7 77.2 84.4 85.8 86.7 86.4 88 81.2 83.9 87 88 89.5 78.1 81.9 83.4 85.7 87.1 87 89.2 78.5 80.9 83.3 85.5 90.5 70.9 73.4 79.9 82.5 82.9 83.2 84.3 72.6 74 80.5
1/2 load 50% 71.6 83 84.4 86.5 86 86 79 83.7 87.4 86.5 89.3 76 80.1 82.5 84.2 86.8 86.1 88.4 78.7 79.5 81.7 84.5 89.5 65.9 70 77.5 79.5 80.9 80.8 82.9 68.7 71.2 80.3
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.75 3.6 6.4 4.9 2.3 0.82 4.6 7.2 7.2 2.7 0.81 6.2 7.5 9.8 2.6 0.85 7.9 7.4 13.2 2.6 0.87 10.6 6.8 18.4 2.8 0.89 13.9 7.2 25 3 High-output design 0.86 5.5 7 9 2.6 0.86 7.9 7.5 13.1 2.7 0.9 10.2 7.2 18.4 3.4 0.92 16.5 7.2 30.5 2.5 0.89 20.1 8.1 36.3 2.8 CENELEC-design 0.77 2.6 4.8 7.3 2 0.75 3.5 5.8 10 2.8 0.78 4.9 5.6 14.6 2.2 0.78 6.5 6.4 20 2.5 0.8 8.3 6.4 26.7 2.3 0.75 12.2 5.6 36.2 2.1 0.75 16.2 6.1 49.3 2.3 High-output design 0.8 4.2 4.5 12.7 2.2 0.83 4.7 4.5 15.1 2.2 0.82 8.4 5.5 26.8 2.5 0.8 11.6 6 36.9 2.7 0.84 17.6 7.5 60.3 2.1 CENELEC-design 0.64 2.3 3.6 7.7 2.1 0.63 3.4 3.2 11.4 1.9 0.69 3.9 4.2 15 2 0.66 5.8 5.1 21.8 2.3 0.68 7.7 4.3 29.8 1.8 0.65 10.6 5.1 39.5 2.1 0.71 13.3 5.3 54.7 2 High-output design 0.71 3.5 4 13.6 1.9 0.71 5.7 4.5 22.3 1.9 0.75 7.2 3.8 31.1 1.9
180 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition protection aluminum motors Technical data for Category 2 D - T = 125 C - IP 65
Current
Torque Tb TN 2.1 1.6 3.6 2.2 1.9 1.9 1.8 2.0 2.2 2.3 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.0032 0.0043 0.0069 0.0082 0.01 0.0038 0.0045 0.0048 0.009 0.0126 13 16 20 23 28 46 53 18 26 32 52 52 46 53 55 56 58 43 46 52
Motor type 8-poles M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD 8-poles M3AAD M3AAD M3AAD Product code 400 V 50 Hz 90 S 3GAA 094 001-E 90 L 3GAA 094 002-E 100 LA 3GAA 104 001-E 100 LB 3GAA 104 002-E 112 M 3GAA 114 101-E 132 S 3GAA 134 001-E 132 M 3GAA 134 002-E 400 V 50 Hz 90 LB 3GAA 094 003-E 100 LC 3GAA 104 003-E 112 MB 3GAA 114 102-E
Full 3/4 Speed load load r/min 100% 75% 695 660 720 695 690 715 715 680 670 685 59.4 59.1 70.7 76.0 74.4 82.9 79.9 63.1 70.0 73.2 56.3 59.5 67.1 76.5 75.9 83.0 80.8 59.8 65.2 72.5
1/2 load 50% 49.1 55.2 59.9 74.6 74.1 80.8 79.1 53.0 63.8 70.0
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.54 1.66 2.7 5 1.6 0.58 2.3 2.1 7.9 1.5 0.47 3.2 3.9 9.9 2.8 0.66 3.1 3.4 15.1 1.7 0.70 4.1 3.2 20.7 1.4 0.62 6.1 3.4 29.3 1.3 0.64 8.4 3.2 40 1.2 High-output design 0.60 2.8 3.0 10.5 1.8 0.70 4.4 3.3 21.3 1.8 0.69 5.7 3.4 27.8 2.1
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 181
Dust ignition protection premium efciency cast iron motors Technical data for Ex tb IIIB/IIIC T125 C Db/Dc, IP 65/IP 55
IE3
IP 65 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Output Motor Product code 400 V 50 Hz 3GGP 201 450J 3GGP 201 460J 3GGP 221 250J 3GGP 251 240J 3GGP 281 220K 3GGP 281 230K 3GGP 311 220K 3GGP 311 230K 3GGP 311 410K 3GGP 311 420K 3GGP 351 210K 3GGP 311 820K 3GGP 351 220K 3GGP 351 230K 3GGP 351 410K 400 V 50 Hz 3GGP 202 450J 3GGP 222 250J 3GGP 222 260J 3GGP 252 230J 3GGP 282 220K 3GGP 282 230K 3GGP 312 230K 3GGP 312 240K 3GGP 312 420K 3GGP 312 820K 3GGP 352 210K 3GGP 312 830K 3GGP 352 220K 3GGP 352 230K 3GGP 352 410K Current Torque Tb TN 3.3 3.5 3.4 2.7 2.9 3.1 2.6 3.0 2.7 2.6 3.1 2.7 3.0 2.8 2.6 2.9 3.3 3.4 3.4 2.8 3.0 3.1 3.2 3.0 2.9 2.7 3.0 2.9 2.9 2.9 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.22 0.22 0.34 0.68 0.9 1.15 1.4 1.7 2.1 2.2 3 2.9 3.4 3.6 4.1 0.37 0.55 0.59 0.98 1.5 1.85 2.9 3.2 3.9 5 5.9 5.5 6.9 7.2 8.4 310 310 406 493 665 725 940 1025 1190 1220 1600 1540 1680 1750 2000 316 410 416 495 665 725 1000 1065 1220 1520 1610 1600 1780 1820 2140 75 75 76 75 77 77 77 77 77 77 83 77 83 83 83 61 67 67 66 66 66 68 68 68 74 74 74 74 74 74
kW type 3000 r/min = 2-poles 30 M3GP 200 MLE 37 M3GP 200 MLF 45 M3GP 225 SME 55 M3GP 250 SMD 75 M3GP 280 SMB 90 M3GP 280 SMC 110 M3GP 315 SMB 132 M3GP 315 SMC 160 M3GP 315 MLA 200 M3GP 315 MLB 1) M3GP 355 SMA 200 250 M3GP 315 LKB 1) M3GP 355 SMB 250 1) M3GP 355 SMC 315 1) M3GP 355 MLA 355 1500 r/min = 4-poles 30 M3GP 200 MLE 37 M3GP 225 SME 45 M3GP 225 SMF 55 M3GP 250 SMC 75 M3GP 280 SMB 90 M3GP 280 SMC 110 M3GP 315 SMC 132 M3GP 315 SMD 160 M3GP 315 MLB 200 M3GP 315 LKB 200 M3GP 355 SMA 250 M3GP 315 LKC 250 M3GP 355 SMB 315 M3GP 355 SMC 355 M3GP 355 MLA
1)
Speed r/min 2957 2958 2970 2977 2979 2981 2982 2984 2982 2982 2984 2981 2983 2984 2982 1478 1482 1479 1483 1486 1487 1490 1490 1489 1490 1490 1491 1491 1491 1491
Full 3/4 1/2 Power IN Is TN Tl load load load factor 100% 75% 50% cos A IN Nm TN CENELEC-design 94.1 94.3 93.7 0.87 52.8 7.7 96.8 2.9 94.6 94.8 94.3 0.86 65.6 8.3 119 3.2 95.0 95.2 94.5 0.88 77.6 8.0 144 3.0 95.2 95.5 95.0 0.91 91.6 8.1 176 2.6 95.5 95.4 94.6 0.87 130 7.3 240 2.1 95.7 95.6 94.8 0.88 154 8.0 288 2.5 95.9 95.7 95.0 0.87 190 6.7 352 1.9 95.9 95.9 95.3 0.88 225 7.9 422 2.4 96.1 96.1 95.8 0.90 267 7.3 512 2.2 96.2 96.2 96.0 0.90 333 6.8 640 1.9 96.2 96.1 95.5 0.89 337 7.6 640 2.0 96.3 96.3 96.2 0.91 411 7.9 800 2.5 96.3 96.3 95.9 0.90 416 7.6 800 2.2 96.4 96.4 95.9 0.89 529 7.8 1008 2.3 96.5 96.5 96.3 0.90 589 7.5 1136 2.3 CENELEC-design 94.2 94.6 94.5 0.86 53.4 7.8 193 3.2 94.6 95.0 94.8 0.88 64.1 7.6 238 2.9 94.8 95.2 95.0 0.87 78.7 8.0 290 3.2 95.3 95.4 95.0 0.86 96.8 7.3 354 2.7 95.7 95.8 95.3 0.85 133 7.4 481 2.5 95.9 96.0 95.5 0.85 159 7.9 577 2.9 96.3 96.3 95.7 0.85 193 7.8 704 2.4 96.4 96.4 95.9 0.85 232 7.9 845 2.6 96.4 96.4 96.1 0.86 278 7.9 1026 2.7 96.5 96.5 96.3 0.87 343 7.6 1281 2.5 96.5 96.5 96.3 0.87 343 7.3 1281 2.1 96.6 96.6 96.4 0.87 429 7.8 1601 2.3 96.6 96.6 96.3 0.87 429 7.8 1601 2.5 96.7 96.7 96.3 0.85 553 7.4 2017 2.8 96.7 96.7 96.4 0.86 616 7.9 2273 2.7
3dB(A) sound pressure level reduction with unidirectional fan construction. Direction of rotation must be stated when ordering, see variant codes 044 and 045
Equipment protection level and equipment group subdivision must be selected when ordering by selecting appropriate variant code; 334 Ex t, dust group IIIB T125 Db (non-conductive dust) acc. to IEC/EN60079-31 335 Ex t, dust group IIIB T125 Dc (non-conductive dust) acc. to IEC/EN60079-31 336 Ex t, dust group IIIC T125 Db (conductive dust) acc. to IEC/EN60079-31 337 Ex t, dust group IIIC T125 Dc (conductive dust) acc. to IEC/EN60079-31
182 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition protection premium efciency cast iron motors Technical data for Ex tb IIIB/IIIC T125 C Db/Dc, IP 65/IP 55
IE3
IP 65 - IC 411 - Insulation class F, temperature rise class B IE3 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Output Motor Product code 400 V 50 Hz 3GGP 203 430J 3GGP 203 440J 3GGP 223 250J 3GGP 253 240J 3GGP 283 220K 3GGP 283 230K 3GGP 313 230K 3GGP 313 240K 3GGP 313 420K 3GGP 313 810K 3GGP 313 830K 3GGP 353 220K 3GGP 353 230K 3GGP 353 420K 3GGP 353 810K 3GGP 353 820K Current Torque Tb TN 3.4 3.4 3.2 3.3 2.6 2.6 2.8 2.9 2.7 2.7 2.9 2.7 2.8 2.7 2.6 2.9 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.49 0.54 0.92 1.74 2.2 2.85 4.9 4.9 6.3 7.3 9.2 9.7 11.3 13.5 15.5 16.5 305 314 410 500 680 725 1000 1040 1200 1410 1600 1680 1820 2180 2500 2600 61 61 61 65 65 65 67 67 68 68 68 73 73 73 76 76
kW type 1000 r/min = 6-poles 18.5 M3GP 200 MLC 22 M3GP 200 MLD 30 M3GP 225 SME 37 M3GP 250 SMD 45 M3GP 280 SMB 55 M3GP 280 SMC 75 M3GP 315 SMC 90 M3GP 315 SMD 110 M3GP 315 MLB 132 M3GP 315 LKA 160 M3GP 315 LKC 160 M3GP 355 SMB 200 M3GP 355 SMC 250 M3GP 355 MLB 315 M3GP 355 LKA 355 M3GP 355 LKB
Speed r/min 987 986 989 990 991 990 993 994 993 993 994 995 995 995 994 995
Full 3/4 1/2 Power IN Is TN Tl load load load factor 100% 75% 50% cos A IN Nm TN CENELEC-design 92.5 92.8 92.4 0.84 34.3 8.1 178 3.2 92.9 93.3 92.9 0.84 40.6 8.2 213 3.3 94.0 94.2 93.8 0.85 54.1 7.9 289 2.5 94.4 94.8 94.6 0.84 67.3 8.2 356 3.3 94.8 94.9 94.2 0.86 79.6 6.9 433 2.4 95.1 95.1 94.7 0.86 97 6.8 530 2.4 95.3 95.3 94.8 0.84 135 7.0 721 2.2 95.5 95.5 94.9 0.83 163 7.2 864 2.4 95.5 95.5 95.1 0.84 197 6.9 1057 2.3 95.7 95.7 95.4 0.83 239 6.9 1269 2.4 95.9 95.9 95.5 0.83 290 7.4 1537 2.7 95.9 95.9 95.5 0.83 290 7.0 1535 2.1 96.0 96.0 95.7 0.83 362 7.3 1919 2.3 96.0 96.0 95.8 0.83 452 7.1 2399 2.3 96.0 96.0 95.8 0.83 570 6.9 3026 2.3 96.0 96.0 95.6 0.80 667 7.7 3407 2.7
Equipment protection level and equipment group subdivision must be selected when ordering by selecting appropriate variant code; 334 Ex t, dust group IIIB T125 Db (non-conductive dust) acc. to IEC/EN60079-31 335 Ex t, dust group IIIB T125 Dc (non-conductive dust) acc. to IEC/EN60079-31 336 Ex t, dust group IIIC T125 Db (conductive dust) acc. to IEC/EN60079-31 337 Ex t, dust group IIIC T125 Dc (conductive dust) acc. to IEC/EN60079-31
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 183
Dust ignition protection aluminum motors Technical data for Category 3D - T = 125 C - IP 55
IE2
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Output Motor Product code 400 V 50 Hz 3GAA 071 311-E 3GAA 071 312-E 3GAA 081 312-E 3GAA 081 313-E 3GAA 091 312-E 3GAA 091 313-E 3GAA 101 312-E 3GAA 111 312-E 3GAA 131 312-E 3GAA 131 313-E 3GAA 161 031-G 3GAA 161 036-G 3GAA 161 037-G 3GAA 181 031-G 3GAA 201 035-G 3GAA 201 036-G 3GAA 221 031-G 3GAA 251 031-G 3GAA 281 031-G 3GAA 281 032-G 400 V 50 Hz 3GAA 071 003-E 3GAA 081 003-E 3GAA 091 003-E 3GAA 101 002-E 3GAA 111 102-E 3GAA 131 004-E 3GAA 131 315-E 3GAA 131 003-E 3GAA 131 316-E 3GAA 131 317-E 3GAA 131 008-E 3GAA 181 032-G 3GAA 201 033-G 3GAA 221 032-G 3GAA 251 032-G Full load 100% 71.6 78.4 80.6 82.1 84.1 84.6 87.9 86.1 88.0 88.5 90.7 91.5 92.0 92.2 93.1 93.4 93.6 94.1 94.5 95.0 76.6 80.7 81.0 84.3 86.4 87.0 90.3 88.7 90.4 91.1 90.2 92.8 93.3 93.9 94.6 3/4 load 75% 72.3 79.8 80.4 82.0 85.0 85.7 87.9 87.0 88.5 88.7 91.5 92.5 93.1 92.7 93.5 93.7 93.9 94.4 94.8 95.2 77.1 82.0 81.2 83.9 87.0 88.0 90.8 89.5 90.7 92.2 91.0 93.5 93.8 94.3 94.9 1/2 load 50% 70.2 78.7 77.3 79.2 83.5 85.5 86.6 88.0 87.6 88.1 91.1 92.2 93.1 92.2 92.9 93.0 93.1 93.8 94.3 94.8 76.4 80.0 79.0 83.7 87.4 86.5 90.4 89.3 89.8 92.4 90.9 93.3 93.2 93.6 94.4 Current Torque Tb TN 2.9 2.8 3.9 3.6 3.3 3.2 4.0 2.8 3.6 3.2 3.1 3.3 3.4 3.3 3.1 3.3 2.5 2.7 2.8 3.2 3.2 3.0 3.0 3.6 3.4 3.0 3.7 3.4 4.0 4.3 3.8 3.3 3.3 2.5 3.1 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00035 0.00045 0.0009 0.0012 0.0024 0.0027 0.005 0.0062 0.016 0.022 0.044 0.053 0.063 0.076 0.178 0.196 0.244 0.507 0.583 0.644 0.00056 0.0011 0.0027 0.005 0.0062 0.018 0.01865 0.018 0.02 0.02559 0.02559 0.092 0.196 0.274 0.583 4.9 5.9 10.5 11 16 18 25 30 42 56 91 105 123 132 210 225 263 304 389 425 6.5 11 18 25 30 52 77 52 81 93 91 149 225 286 351 58 58 60 60 60 63 62 68 73 73 69 69 69 69 72 72 74 75 75 75 58 60 68 68 68 68 68 68 69 68 69 69 72 74 75
kW type 3000 r/min = 2-poles 0.37 M3AAD 0.55 M3AAD 0.75 M3AAD 1.1 M3AAD 1.5 M3AAD 2.2 M3AAD 3 M3AAD 4 M3AAD 5.5 M3AAD 7.5 M3AAD 11 M3AA 15 M3AA 18.5 M3AA 22 M3AA 30 M3AA 37 M3AA 45 M3AA 55 M3AA 75 M3AA 90 M3AA 3000 r/min = 2-poles 2) 0.75 M3AAD 1) 2) M3AAD 1.5 1) 2) M3AAD 2.7 1) 2) M3AAD 4 1) 2) M3AAD 5.5 1) 2) 9.2 M3AAD 11 M3AAD 1) 2) M3AAD 11 15 M3AAD 18.5 M3AAD 1) 2) M3AAD 22 30 M3AA 45 M3AA 55 M3AA 75 M3AA
1) 2)
Speed r/min 2800 2790 2895 2880 2900 2875 2930 2885 2915 2915 2938 2934 2932 2952 2956 2959 2961 2967 2968 2971 2785 2830 2860 2900 2850 2875 2900 2890 2905 2895 2890 2950 2957 2961 2970
71 A 71 B 80 B 80 C 90 L 90 LB 100 LB 112 MB 132 SB 132 SC 160 MLA 160 MLB 160 MLC 180 MLA 200 MLA 200 MLB 225 SMA 250 SMA 280 SMA 280 SMB 71 C 80 C 90 LB 100 LB 112 MB 132 SBB 132 SMB 132 SC 132 SMC 132 SME 132 SME 180 MLB 200 MLC 225 SMB 250 SMB
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.76 0.98 5.1 1.26 3.0 0.78 1.29 5.3 1.88 2.9 0.79 1.7 8.1 2.4 3.7 0.81 2.3 7.6 3.6 2.8 0.86 2.9 7.6 4.9 2.5 0.85 4.4 6.9 7.3 2.8 0.86 5.7 8.7 9.7 3.3 0.88 7.6 7.6 13.2 2.5 0.82 11 7.9 18 2.6 0.87 14 7.6 24.5 2.2 0.91 19.2 7.5 35.7 2.4 0.91 26 7.5 48.8 2.5 0.92 31.5 7.5 60.2 2.9 0.87 39.5 7.7 71.1 2.8 0.90 51.6 7.7 96.9 2.7 0.90 63.5 8.2 119 3.0 0.88 78.8 6.7 145 2.5 0.88 95.8 6.8 177 2.2 0.89 128 7.1 241 2.5 0.89 153 7.8 289 2.6 High-output design 0.80 1.76 5.3 2.5 3.2 0.83 3.2 5.8 5 2.6 0.86 5.5 7.0 9 2.6 0.86 7.9 7.5 13.1 2.7 0.90 10.2 7.2 18.4 3.4 0.92 16.5 7.2 30.5 2.5 0.87 20.2 8.5 36.2 2.7 0.89 20.1 8.1 36.3 2.8 0.84 28.5 9.1 49.3 3.3 0.89 32.9 9.7 61 3.2 0.85 41.4 9.7 72.6 3.9 0.88 53 7.9 97.1 2.8 0.88 79.1 8.1 145 3.1 0.88 96 6.5 177 2.4 0.89 128 7.6 241 2.8
184 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition proof aluminum motors Technical data for Category 3D - T = 125 C - IP 55
IE2
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Output Motor Product code 400 V 50 Hz 3GAA 072 311-E 3GAA 072 312-E 3GAA 082 311-E 3GAA 082 314-E 3GAA 092 314-E 3GAA 092 315-E 3GAA 102 313-E 3GAA 102 314-E 3GAA 112 312-E 3GAA 132 312-E 3GAA 132 314-E 3GAA 162 031-G 3GAA 162 032-G 3GAA 182 031-G 3GAA 182 032-G 3GAA 202 031-G 3GAA 222 031-G 3GAA 222 032-G 3GAA 252 031-G 3GAA 282 031-G 3GAA 282 032-G 400 V 50 Hz 3GAA 072 003-E 3GAA 082 003-E 3GAA 082 004-E 3GAA 092 003-E 3GAA 092 004-E 3GAA 102 003-E 3GAA 112 102-E 3GAA 132 004-E 3GAA 132 315-E 3GAA 132 316-E 3GAA 162 033-G 3GAA 132 007-E 3GAA 162 034-G 3GAA 202 032-G 3GAA 222 033-G 3GAA 252 032-G Full load 100% 65.1 69.7 74.1 79.9 83.7 84.2 87.1 85.7 86.7 89.0 89.1 90.4 91.4 91.9 92.4 93.2 93.4 93.9 94.4 94.3 94.9 69.0 76.0 76.7 79.3 80.0 83.2 85.1 89.8 90.4 90.6 91.4 89.4 91.6 93.4 94.0 94.7 3/4 load 75% 66.0 71.9 75.9 80.4 84.1 84.1 86.8 86.1 86.5 89.8 89.9 91.6 92.4 92.9 93.3 94.0 93.9 94.3 95.0 95.0 95.3 69.3 76.9 77.5 78.5 80.9 83.3 85.5 90.5 91.0 91.3 92.5 90.0 93.0 94.4 94.7 95.0 1/2 load 50% 62.7 71.1 75.0 78.6 83.0 81.9 84.8 85.1 85.2 89.1 89.5 91.3 92.2 92.7 93.2 93.7 93.4 93.9 94.7 94.7 95.0 68.5 76.3 77.9 78.7 79.5 81.7 84.5 89.5 90.1 91.1 92.3 89.5 93.2 94.4 94.5 94.8 Current Torque Tb TN 2.1 2.2 2.2 2.8 3.2 3.5 3.4 3.0 3.4 2.6 2.6 2.8 3.0 2.9 3.0 3.0 2.9 3.2 2.9 3.0 3.6 2.4 2.6 2.5 2.4 2.4 2.8 3.1 2.8 3.1 2.9 3.2 2.6 2.9 2.9 3.1 3.5 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00066 0.0008 0.0013 0.0016 0.0043 0.0048 0.009 0.011 0.0126 0.038 0.048 0.081 0.099 0.166 0.195 0.309 0.356 0.44 0.765 0.866 0.941 0.0011 0.0023 0.0023 0.0043 0.0048 0.009 0.0126 0.048 0.0433 0.0517 0.11 0.05166 0.125 0.343 0.474 0.866 5.2 5.9 8.5 12 16 17 25 28 34 48 59 99 118 146 163 218 240 273 314 389 418 6.5 10.5 10.5 16 17 25 34 59 83 92 127 92 140 234 287 350 45 45 50 50 50 50 54 63 64 66 63 62 62 62 62 63 66 66 67 67 67 45 50 50 50 50 60 64 59 65 67 62 69 62 63 66 67
kW type 1500 r/min = 4-poles 0.25 M3AAD 0.37 M3AAD 0.55 M3AAD 0.75 M3AAD 1.1 M3AAD 1.5 M3AAD 2.2 M3AAD 3 M3AAD 4 M3AAD 5.5 M3AAD 7.5 M3AAD 11 M3AA 15 M3AA 18.5 M3AA 22 M3AA 30 M3AA 37 M3AA 45 M3AA 55 M3AA 1) M3AA 75 1) M3AA 85 1500 r/min = 4-poles 0.55 M3AAD 1) 2) M3AAD 0.95 1) 2) M3AAD 1.1 1) 2) M3AAD 1.85 1) 2) 2.2 M3AAD 1) 2) M3AAD 4 1) 2) M3AAD 5.5 1) M3AAD 9.2 11 M3AAD 15 M3AAD 18.5 M3AA 1) 2) M3AAD 18.5 22 M3AA 37 M3AA 55 M3AA 68 M3AA
1) 2)
Speed r/min 1365 1355 1375 1415 1435 1435 1450 1445 1445 1465 1460 1466 1470 1477 1475 1480 1479 1480 1480 1478 1480 1375 1395 1395 1390 1390 1420 1420 1455 1460 1455 1469 1445 1463 1479 1478 1481
71 A 71 B 80 A 80 D 90 LB 90 LD 100 LC 100 LD 112 MB 132 M 132 MA 160 MLA 160 MLB 180 MLA 180 MLB 200 MLA 225 SMA 225 SMB 250 SMA 280 SMA 280 SMB 71 C 80 C 80 C 90 L 90 LB 100 LC 112 MB 132 MBA 132 SMB 132 SMD 160 MLC 132 SMD 160 MLD 200 MLB 225 SMC 250 SMB
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.76 0.72 4.0 1.74 2.0 0.79 0.96 3.8 2.6 2.0 0.78 1.37 4.5 3.8 1.9 0.75 1.8 5.8 5 2.6 0.78 2.4 6.6 7.3 2.9 0.76 3.3 7.0 9.9 3.1 0.78 4.6 7.3 14.4 2.8 0.79 6.3 7.0 19.8 2.4 0.75 8.8 7.3 26.4 3.1 0.79 11.2 6.3 35.8 1.9 0.79 15.3 6.4 49 1.8 0.84 20.9 6.8 71.6 2.2 0.83 28.5 7.1 97.4 2.6 0.84 34.5 7.2 119 2.6 0.84 40.9 7.3 142 2.6 0.84 55.3 7.4 193 2.8 0.84 68 7.1 238 2.6 0.85 81.3 7.5 290 2.8 0.85 98.9 7.0 354 2.6 0.85 135 7.1 484 2.8 0.84 153 8.0 548 3.4 High-output design 0.76 1.51 4.2 3.8 2.4 0.80 2.2 5.2 6.5 2.5 0.79 2.6 5.0 7.5 2.5 0.80 4.2 4.5 12.7 2.2 0.83 4.7 4.5 15.1 2.2 0.82 8.4 5.5 26.8 2.5 0.80 11.6 6.0 36.9 2.7 0.84 17.6 7.5 60.3 2.1 0.79 22.2 7.7 71.9 2.1 0.77 31 7.1 98.4 2.4 0.84 34.7 7.6 120 3.0 0.78 38.2 6.7 122 2.3 0.85 40.7 6.9 143 2.5 0.85 67.2 7.1 238 2.6 0.85 99.3 7.4 355 2.9 0.84 123 7.9 438 3.1
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 185
Dust ignition proof aluminum motors Technical data for Category 3D - T = 125 C - IP 55
IE2
IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according to IEC 60034-30; 2008
Efciency IEC 60034-2-1; 2007 Output Motor Product code 400 V 50 Hz 3GAA 073 311-E 3GAA 073 312-E 3GAA 083 311-E 3GAA 083 312-E 3GAA 093 313-E 3GAA 093 314-E 3GAA 103 312-E 3GAA 113 312-E 3GAA 133 311-E 3GAA 133 312-E 3GAA 133 314-E 3GAA 163 031-G 3GAA 163 032-G 3GAA 183 031-G 3GAA 203 031-G 3GAA 203 032-G 3GAA 223 031-G 3GAA 253 031-G 3GAA 283 031-G 3GAA 283 032-G 400 V 50 Hz 3GAA 073 003-E 3GAA 083 003-E 3GAA 093 003-E 3GAA 103 002-E 3GAA 113 102-E 3GAA 163 033-G 3GAA 203 033-G 3GAA 223 034-G 3GAA 253 032-G 3GAA 253 033-G Full load 100% 60.4 64.0 69.9 72.1 77.6 78.1 80.3 81.8 83.3 84.9 86.1 88.6 89.3 90.5 91.6 92.0 92.7 93.1 93.2 93.2 61.5 70.1 74.4 78.0 79.7 89.7 92.0 93.1 93.4 93.2 3/4 load 75% 60.0 63.6 71.4 73.4 76.2 78.6 81.4 83.1 83.6 85.3 86.1 89.9 90.7 91.4 92.3 93.0 93.3 93.8 94.0 94.1 61.2 70.3 72.6 74.0 80.5 91.2 93.1 94.0 94.1 94.1 1/2 load 50% 55.0 59.5 68.8 71.2 75.6 76.4 80.7 82.5 81.7 83.9 84.3 89.7 90.6 91.0 91.7 92.8 92.9 93.4 93.9 94.0 59.0 69.1 68.7 71.2 80.3 91.2 92.9 94.0 93.9 94.0 Current Torque Tb TN 2.0 2.2 2.0 1.9 2.3 2.3 2.0 2.2 2.3 2.2 2.8 3.2 2.9 2.8 2.9 2.8 2.9 2.7 2.6 2.8 2.4 2.4 2.2 2.3 2.2 3.6 2.8 2.6 2.7 2.8 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00092 0.0012 0.002 0.0026 0.0048 0.0056 0.009 0.01 0.031 0.038 0.049 0.087 0.114 0.192 0.382 0.448 0.663 1.13 1.369 1.5 0.0015 0.0031 0.0048 0.009 0.0126 0.131 0.531 0.821 1.369 1.5 5.5 6.5 9 10 18 20 26 28 39 46 59 98 125 162 196 218 266 294 378 404 7 11 18 26 32 138 245 300 341 367 42 42 47 47 44 44 49 56 57 61 61 59 59 59 63 63 63 63 63 63 44 47 44 49 76 59 63 63 63 63
kW type 1000 r/min = 6-poles 0.18 M3AAD 0.25 M3AAD 0.37 M3AAD 0.55 M3AAD 0.75 M3AAD 2) M3AAD 1.1 1.5 M3AAD 2) M3AAD 2.2 3 M3AAD 4 M3AAD 5.5 M3AAD 7.5 M3AA 11 M3AA 15 M3AA 18.5 M3AA 22 M3AA 30 M3AA 37 M3AA 1) M3AA 45 1) M3AA 55 1000 r/min = 6-poles 0.37 M3AAD 1) 2) M3AAD 0.75 1) 2) M3AAD 1.3 1) 2) M3AAD 2.2 1) 2) M3AAD 3 15 M3AA 1) M3AA 30 37 M3AA 45 M3AA 1) M3AA 55
1) 2)
Speed r/min 895 895 910 905 930 930 945 940 960 960 965 975 972 981 988 987 986 989 988 988 870 905 910 940 920 971 985 985 989 988
71 A 71 B 80 A 80 B 90 LB 90 LD 100 LC 112 MB 132 S 132 MA 132 MC 160 MLA 160 MLB 180 MLA 200 MLA 200 MLB 225 SMA 250 SMA 280 SMA 280 SMB 71 C 80 C 90 LB 100 LC 112 MB 160 MLC 200 MLC 225 SMB 250 SMB 250 SMC
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.73 0.58 3.1 1.92 1.9 0.71 0.79 3.3 2.6 2.2 0.73 1.04 3.6 3.8 1.6 0.69 1.59 3.3 5.8 1.8 0.71 1.96 4.0 7.7 2.0 0.66 3 4.0 11.2 1.9 0.73 3.6 3.9 15.1 1.7 0.73 5.3 4.4 22.3 1.8 0.65 7.9 4.3 29.8 1.6 0.68 10 4.6 39.7 1.5 0.67 13.7 6.2 54.4 2.5 0.79 15.4 7.4 73.4 1.7 0.79 22.5 7.5 108 1.9 0.77 31 6.5 146 1.8 0.80 36.4 6.7 178 2.3 0.82 42 6.6 212 2.2 0.83 56.2 7.0 290 2.6 0.82 69.9 6.8 357 2.4 0.84 82.9 6.8 434 2.4 0.84 101 7.1 531 2.6 High-output design 0.72 1.2 3.1 4 2.5 0.76 2 3.9 7.9 2.5 0.71 3.5 4.0 13.6 1.9 0.71 5.7 4.5 22.3 1.9 0.75 7.2 3.8 31.1 1.9 0.77 31.3 7.3 147 1.8 0.83 56.7 6.9 290 2.3 0.83 69.1 6.6 358 2.3 0.83 83.7 7.0 434 2.5 0.84 101 7.1 531 2.6
186 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition proof aluminum motors Technical data for Category 3D - T = 125 C - IP 55
Current
Torque Tb TN 2.3 2.4 2.0 1.9 2.1 1.6 3.6 2.2 1.9 1.9 1.8 2.6 2.6 2.8 2.6 2.4 2.3 2.3 2.4 2.3 2.2 2.5 2.0 2.2 2.3 Moment of Sound inertia pressure J = 1/4 GD2 Weight level LPA kgm2 kg dB 0.00092 0.0012 0.0018 0.0024 0.0032 0.0043 0.0069 0.0082 0.01 0.0038 0.0045 0.068 0.085 0.132 0.214 0.45 0.669 0.722 1.404 1.505 0.0015 0.0031 0.0048 0.009 0.0126 5.5 6.5 8.5 9.5 13 16 20 23 28 46 53 84 98 137 175 217 266 279 340 403 7 11 18 26 32 40 43 45 50 52 52 46 53 55 56 58 59 59 59 59 60 63 63 63 63 40 45 43 46 52
Motor type 8-poles M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD M3AAD M3AA M3AA M3AA M3AA M3AA M3AA M3AA M3AA M3AA 8-poles M3AAD M3AAD M3AAD M3AAD M3AAD Product code 400 V 50 Hz 3GAA 074 001-E 3GAA 074 002-E 3GAA 084 001-E 3GAA 084 002-E 3GAA 094 001-E 3GAA 094 002-E 3GAA 104 001-E 3GAA 104 002-E 3GAA 114 101-E 3GAA 134 001-E 3GAA 134 002-E 3GAA 164 031-G 3GAA 164 032-G 3GAA 164 033-G 3GAA 184 031-G 3GAA 204 031-G 3GAA 224 031-G 3GAA 224 032-G 3GAA 254 031-G 3GAA 284 031-G 400 V 50 Hz 3GAA 074 003-E 3GAA 084 003-E 3GAA 094 003-E 3GAA 104 003-E 3GAA 114 102-E
Speed r/min 660 670 685 685 695 660 720 695 690 715 715 728 726 727 731 737 739 738 742 740 660 700 680 670 685
Full load 100% 49.4 51.4 63.5 67.1 59.4 59.1 70.7 76.0 74.4 82.9 79.9 84.1 84.7 86.1 86.8 90.2 91.0 91.6 92.4 92.3 47.2 57.5 63.1 70.0 73.2
3/4 load 75% 46.0 47.5 62.0 67.2 56.3 59.5 67.1 76.5 75.9 83.0 80.8 85.1 86.0 87.3 88.4 91.3 92.0 92.4 92.9 93.0 44.8 56.0 59.8 65.2 72.5
1/2 load 50% 38.5 39.9 56.3 63.4 49.1 55.2 59.9 74.6 74.1 80.8 79.1 83.7 84.9 86.6 87.8 90.9 91.5 92.0 92.3 92.7 45.0 55.0 53.0 63.8 70.0
71 A 71 B 80 A 80 B 90 S 90 L 100 LA 100 LB 112 M 132 S 132 M 160 MLA 160 MLB 160 MLC 180 MLA 200 MLA 225 SMA 225 SMB 250 SMA 280 SMA 71 C 80 C 90 LB 100 LC 112 MB
Power IN Is TN Tl factor cos A IN Nm TN CENELEC-design 0.59 0.44 2.0 1.3 2.4 0.56 0.6 2.1 1.71 2.8 0.62 0.65 2.8 2.5 1.6 0.63 0.85 2.8 3.4 1.4 0.54 1.66 2.7 5 1.6 0.58 2.3 2.1 7.9 1.5 0.47 3.2 3.9 9.9 2.8 0.66 3.1 3.4 15.1 1.7 0.70 4.1 3.2 20.7 1.4 0.62 6.1 3.4 29.3 1.3 0.64 8.4 3.2 40 1.2 0.67 10.2 5.4 52.4 1.5 0.67 13.9 5.6 72.3 1.4 0.65 19.3 4.7 98.5 1.5 0.67 27.3 4.4 143 1.8 0.74 32.4 5.3 194 2.0 0.73 40.1 5.2 239 2.0 0.74 46.8 5.5 284 2.0 0.71 66 5.8 386 2.6 0.74 78.1 5.6 477 2.4 High-output design 0.66 0.83 2.2 2.6 2.3 0.62 1.49 3.3 5 2.5 0.60 2.8 3.0 10.5 1.8 0.70 4.4 3.3 21.3 1.8 0.69 5.7 3.4 27.8 2.1
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 187
Balancing 052 417 423 424 Vibration acc. to Grade A (IEC 60034-14). Vibration acc. to Grade B (IEC 60034-14). Balanced without key. Full key balancing. S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P S P P P
Bearings and Lubrication 036 037 040 041 043 058 060 107 128 129 130 194 433 506 654 795 796 797 798 799 800 Brakes 412 Built-on brake. R R R R R R R R R NA NA NA NA NA NA Transport lock for bearings. Roller bearing at D-end. Heat resistant grease. Bearings regreasable via grease nipples. SPM compatible nipples for vibration measurement Angular contact bearing at D-end, shaft force away from bearing. Angular contact bearing at D-end, shaft force towards bearing. Pt100 2-wire in bearings. Double Pt100, 2-wire in bearings Double Pt100, 3-wire in bearings Pt100 3-wire in bearings. 2Z bearings greased for life at both ends. Outlet grease collector Nipples for vibration measurement : SKF Marlin Quick Connect stud CMSS-2600-3 Provision for vibration sensors (M8x1) Lubrication information plate Grease nipples JIS B 1575 Pt 1/8 Type A Stainless steel SPM nipples Stainless steel grease nipples Grease nipples at type DIN 3404, thread M10x1 Grease nipples JIS B 1575 Pt 1/8" pin type NA NA NA P NA NA NA NA NA NA P NA NA NA NA NA NA P NA NA NA NA NA NA P NA NA NA NA NA NA P NA NA NA NA NA NA P NA NA NA P M P P P M P P M P P P M P P M P P P M P P M P P P M P P M P P P M P P S P P P M P P S P P P M P P S P P P M P P S P P P P P NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA NA NA NA NA S NA NA P P P P M NA P P P P P M NA P P P P P M NA P P P P P M NA P P P P P M NA P P P P P NA P P P P P P NA P P P P P P NA P P P P P P NA P P NA NA NA NA NA NA NA NA NA NA NA P P P P NA NA S NA P NA NA NA S NA P NA NA NA S NA P NA NA NA S NA P NA NA NA S NA P NA NA NA S NA P NA M M P S S P M M P S S P M M P S S P M M P S S P M M P S S P M M P S S P M M P S S P M M P S S P P P P S S P
Branch standard designs 178 204 209 396 Stainless steel / acid proof bolts. Jacking bolts for foot mounted motors. Non-standard voltage or frequency, (special winding). Motor designed for ambient temperature -20 C to -40 C, wtih space heaters (code 450/451 must be added). 397 Motor designed for ambient temperature -40 C to -55 C, wtih space heaters (code 450/451 must be added).
1)
P NA P NA
P NA P NA
P NA P NA
P NA P NA
P NA P NA
P NA P NA
M P P P
M P P P
M P P P
M P P P
M P P P
M P P P
M P P P
M S P P
P S P P
NA
NA
NA
NA
NA
NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
188 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant
Frame size 71 80 NA NA P NA 90 NA NA P NA 100 NA NA P NA 112 NA NA P NA 132 NA NA S NA 160 P P S P 180 P P S P 200 P P S P 225 P P S P 250 P P S P 280 P P P R 315 P P P R 355 P P P NA 400 P P P NA
Motor designed for ambient temperature -20 C to -40 C. Motor designed for ambient temperature -40 C to -55 C. Corrosion protected stator and rotor core. Special design shaft upwards (V3, V36, V6) for outdoor mounting.
NA NA P NA
Cooling system 044 Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors. 045 Unidirectional fan for reduced noise level. Rotation counter clockwise seen from D-end. Available only for 2-pole motors. 068 183 206 422 791 Light alloy metal fan Separate motor cooling (fan axial, N-end). Steel fan Separate motor cooling (fan top, N-end). Stainless steel fan cover P NA NA NA NA P NA NA NA NA P NA NA NA NA P NA NA NA NA P NA NA NA NA P NA NA NA NA M P P NA NA M P P NA NA M P P NA NA M P P NA P M P P NA P M P P P P M P P P P M P P P P P P P P P NA NA NA NA NA NA NA NA NA NA NA P P P P NA NA NA NA NA NA NA NA NA NA NA P P P P
Drain holes 065 448 Plugged existing drain holes. Draining holes with metal plugs. S NA S NA S NA S NA S NA S NA S P S P M P M P M P M P M P M P P P
Hazardous Environments 334 335 336 337 813 814 Ex t, Dust group III B T125C Db (non-conductive dust) acc. IEC/EN60079-31 Ex t, Dust group III B T125C Dc (non-conductive dust) acc. IEC/EN60079-31 Ex t, Dust group III C T125 Db (conductive dust) acc. IEC/EN60079-31 Ex t, Dust group III C T125 Dc (conductive dust) acc. IEC/EN60079-31 Thermistor-based surface temperature protection T4 for frequency convertor duty. Ex tD (DIP) motors, temperature class T 150C. P P P P P P M M M M M M M P P NA NA NA NA NA NA P P P P P P P P P P P P P P P M M P P P P P P P P P P P P P M M P P P P P P P P P P P P P M M P P P P P P P P P P P P P M M P P P P P P P
Heating elements 450 451 Heating element, 100-120V. Heating element, 200-240V. P P P P P P P P P P P P M M M M M M M M M M M M M M M M P P
Insulation system 014 405 Winding insulation class H. Special winding insulation for frequency converter supply. Mounting arrangements 008 IM 2101 foot/ange mounted, IEC ange, from IM 1001 (B34 from B3).
1)
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
NA
NA
NA
NA
NA
NA
NA
NA
NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 189
Code 1)
Variant
Frame size 71 80 P P P 90 P P P 100 P P P 112 P P P 132 P P P 160 M NA M 180 M NA M 200 M NA M 225 M NA M 250 M NA M 280 M NA M 315 M NA M 355 M NA M 400 P NA P
IM 2001 foot/ange mounted, IEC ange, from IM 1001 (B35 from B3). IM 3601 ange mounted, IEC ange, from IM 3001 (B14 from B5). Modied for specied mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001) & IM B34 (2101)
P P P
305
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Noise reduction 055 Painting 105 111 114 115 168 303 754 710 Paint thickness report. Painting system C3M acc. to ISO 12944-5:2007 Special paint colour, standard grade. Painting system C4M acc. To ISO 12944-5:2007 Primer paint only. Painted insulation layer on inside of the terminal boxes. Painting system C5M acc. to ISO 12944-5:2007 Thermally sprayed zinc metallaizing with acrylic top coat Protection 005 072 073 076 401 403 783 Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Sealed against oil at D-end. Draining holes with plugs in open position. Protective roof, horizontal motor. Degree of protection IP56. Labyrinth sealing at D-end. P P NA P NA P NA P P NA P NA P NA P P NA P NA P NA P P NA P NA P NA P P NA P NA P NA P P NA P NA P NA M M P P P M P M M P P P M P M M P S P M P M M P S P M P M M P S P M P M NA P S P M P M NA P S P M P M NA NA S P M S P NA NA S P P S P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P S P P P NA P S P P P NA P S P P P NA P S P P P NA P S P P P NA P S P P P NA P S M P P P P S M P P P P S M P P P P S M P P P P S M P P P P S M P P P P S M P P P P S M P P P P S P P P P Noise reduction cover for foot mounted motor NA NA NA NA NA NA NA NA NA NA NA R R R R
Rating & instruction plates 002 004 095 126 135 139 159 161 163 333 Restamping voltage, frequency and output, continuous duty. Additional text on std rating plate (max 12 digits on free text line). Restamping output (maintained voltage, frequency), P intermittent duty. Tag plate Mounting of additional identication plate, stainless. Additional identication plate delivered loose. Additional plate with text "Made in ...." Additional rating plate delivered loose. Frequency converter rating plate. Rating data according to quotation. For Export Only P P P P P P M M M M M M M M P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P M M M M M P M M M M M P M M M M M P M M M M M P M M M M M P M M M M M P M M M M M P M M M M M P P P P P P P P P P P M M M M M M M M P NA NA NA NA NA NA P P P P P P P P P P P P P P P M M M M M M M M P
Shaft & rotor 069 070 Two shaft extensions as per basic catalogue. One or two special shaft extensions, standard shaft material.
1)
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
190 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant
Frame size 71 80 S P R 90 S P R 100 S P R 112 S P R 132 S P R 160 S P R 180 S P R 200 S P R 225 S P R 250 S P R 280 P S P 315 P S P 355 P S P 400 P S P
Shaft extension with closed key-way. Shaft extension with open key-way. Stainless steel shaft (standard or non-standard design).
S P R
Standards and Regulations 151 421 482 504 Design according to SHELL DEP 33.66.05.31-Gen. June 2007 VIK design (Verband der Industriellen Energie- und Kraftwirtschaft e.V.). Design according to Neste OY & Jacobs, specication N-114 E, rev 5, 1.12.2010 Design according to Neste OY & Jacobs, specication N-114 E, rev 5, 01.12.2010 with SPM adapter 505 VIK design with ABB standard shaft dimensions (Verband der Industriellen Energie- und Kraftwirtschaft e.V.). 540 541 542 775 778 779 782 788 802 China energy label Inmetro certication NBR design Design according to SHELL DEP 33.66.05.31-Gen. January 1999 design. GOST Export/Import Certicate (Russia). SASO Export/Import Certicate (Saudi Arabia) Fullling CQST Certication requirements (China) Documentation for Korean KOSHA certication GOST Kazakhstan certied NA P NA P NA NA P NA P NA NA P NA P NA NA P NA P NA NA P NA P NA NA P NA P NA P M M M P P M M M P P M M M P P M M M P P M M M P P M M M P P M M M P P P P M P P P P P P P NA NA P P NA NA P P NA NA P P NA NA P P NA NA P P NA NA P M R R M M R R M M R R M M R R M M R R M M R R P M R R P M R R P NA R R P NA NA NA NA NA NA P P P P P P P P P NA NA NA NA NA NA P P P P P P P P P NA NA NA NA NA NA P P P P P P P P P NA NA NA NA NA NA M M M M M P P P P P P P P P P M M M M M P P P P
Stator winding temperature sensors 120 328 435 436 439 441 445 446 502 503 511 KTY 84-130 (1 per phase) in stator winding. PTC - thermistors (3 in series), 120 C, in stator winding PTC - thermistors (3 in series), 130 C, in stator winding. PTC - thermistors (3 in series), 150 C, in stator winding. PTC - thermistors (2x3 in series), 150 C, in stator winding. PTC - thermistors (3 in series, 130 C & 3 in series, 150 C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Pt-100 2-wire in stator winding, 2 per phase Pt-100 3-wire in stator winding, 1 per phase. Pt-100 3-wire in stator winding, 2 per phase. PTC thermistors (2 x 3 in series), 130 C, in stator winding Terminal box 019 021
1)
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
NA NA NA S P P NA NA NA NA P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P M M S M P P P P P P
P P P S P P P P P P P
Larger than standard terminal box. Terminal box LHS (seen from D-end).
NA NA
NA NA
NA NA
NA NA
NA NA
NA NA
NA P
NA P
NA P
NA P
NA P
P P
P P
P P
P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 191
Code 1)
Variant
Frame size 71 80 NA P NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA 90 NA P NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA 100 NA P NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA 112 NA P NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA 132 NA P NA NA NA NA NA NA NA NA NA NA NA NA NA P NA NA P P P P P NA NA NA NA NA 160 M M P P P S NA P P NA NA M M S P P P P M P M S P P M M S P 180 M M P P P S NA P P NA NA M M S P P P P M P M S P P M M S P 200 M M P P P S NA P P NA P M M P P P P P M P M S P P M M S P 225 M M P P P S NA P P NA P M M P P P P P M P M S P P M M S P 250 M M P P P S NA P P NA P M M P P P P P M P M S P P M M S P 280 M M P P P S S P P M P M M P P P NA P M P M S P P P P S P 315 M M P P P S S P P M P M M P P P NA P M P M S P P P P S P 355 M M P P P NA S P P M P R P P P P NA P M P M S P P P P S P 400 P P P P P NA S P P NA P R P P P P NA P P P P S P P P P P P
022 157 180 231 380 400 402 413 418 447 466 468 469 567 568 728 729 730 732 733 734 736 737 741 743 744 745 746 Testing 145 146 148 149 150 222
Cable entry LHS (seen from D-end). Terminal box degree of protection IP65. Terminal box RHS (seen from D-end). Standard cable glands with clamping device. Separate terminal box for temperature detectors, std. material 4 x 90 degr turnable terminal box. Terminal box adapted for Al cables. Extended cable connection, no terminal box. Separate terminal box for auxiliaries, standard material. Top mounted separate terminal box for monitoring equipment. Terminal box at N-end. Cable entry from D-end. Cable entry from N-end. Separate terminal box material: Cast Iron Separate terminal box for heating elements, std. material Standard cable gland, Ex d IIB, armoured cable, double sealing. Aluminum non-drilled ange for cable glands Prepared for NPT cable glands Standard cable gland, Ex d IIB, armoured cable. Standard cable gland, Ex d IIB, non-armoured cable. Standard cable gland, Ex d IIC, armoured cable. Standard cable gland Ex e acc. to EN-standards. Standard cable gland Ex e with clamping device acc. to EN-standards. Motor equipped with Ex e terminal box (EN 50019). Painted non-drilled ange in steel for cable glands Stainless steel non-drilled ange for cable glands. Painted steel ange equipped with nickle plated brass cable glands Stainless steel cable ange equipped with standard nickle plated brass cable glands
NA P NA NA NA NA NA NA NA NA NA NA NA NA NA R NA NA R R R P P NA NA NA NA NA
Type test report from a catalogue motor, 400V 50Hz. Type test with report for one motor from specic delivery batch. Routine test report. Test according to separate test specication. with other codes. Torque/speed curve, type test and multi-point load test with report for one motor from specic delivery batch.
P P P R
P P P R P P
P P P R P P
P P P R P P
P P P R P P
P P P R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
M P M R P P
P P P R P P
760
1)
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
192 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code 1)
Variant
Frame size 71 80 P P R P 90 P P R P 100 P P R P 112 P P R P 132 P P R P 160 P P P P 180 P P P P 200 P P P P 225 P P P P 250 P P P P 280 P P P P 315 P P P P 355 P P P P 400 P P P P
Vibration spectrum test for one motor from specic delivery batch. Noise level test for one motor from specic delivery batch. Noise spectrum test for one motor from specic delivery batch. Test for one motor from specic delivery batch with ABB frequency converter available at ABB test eld. ABB standard test procedure.
P P R P
Variable speed drives 181 Rating plate with ABB standard loadability values for NA VSD operation. Other auxiliaries for VSD operation to be selected as necessary. 470 479 680 701 704 747
1)
NA
NA
NA
NA
NA
Prepared for hollow shaft pulse tacho (L&L equivalent). Mounting of other type of pulse tacho with shaft extension, tacho not included. 2048 pulse tacho, Ex d, tD, L&L 841910001 Insulated bearing at N-end. EMC cable gland. 1024 pulse tacho, Ex d, tD, L&L 841910002
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
NA NA NA NA NA NA
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P NA P P
P P P M P P
P P P M P P
P P P M P P
P P P P P P
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 193
Variant
Frame size 71 80 90 100 112 132 160 180 200 225 250 280
Balancing 417 423 424 Vibration acc. to Grade B (IEC 60034-14). Balanced without key. Full key balancing. NA P P NA P P P P P P P P P P P P P P R R P R P P R P P R P P R P P R P P
Bearings and Lubrication 036 037 039 040 041 042 043 057 058 059 061 188 194 195 796 797 798 Transport lock for bearings. Roller bearing at D-end. Cold resistant grease. Heat resistant grease. Bearings regreasable via grease nipples. Locked drive-end. NA NA M M NA S NA NA M M NA S NA M NA NA NA NA S S NA NA NA M P M M P S R M M M NA M NA NA NA R NA M P M M P S R M M M NA S NA NA NA R NA M P M M P S R M M M NA M NA NA NA R NA M P M M P S R M M M NA M NA NA NA R NA M M NA NA M S M M M M NA S S S M M M M M NA NA M S M M M M NA S S S M M M M M NA NA M S M M M M NA S S S M M M M M NA NA M S M M M M NA S S S M M M M M NA NA M S M M M M NA S S S M M M M M NA NA S S M M M M NA S R R M M M
SPM compatible nipples for vibration measurement NA 2RS bearings at both ends. Angular contact bearing at D-end, shaft force away from bearing. Angular contact bearing at N-end, shaft force towards bearing. Angular contact bearing at N-end, shaft force away from bearing. 63-series bearings. 2Z bearings greased for life at both ends. Bearings greased for life. Grease nipples JIS B 1575 Pt 1/8 Type A Stainless steel SPM Nipples Stainless steel grease nipples NA S S NA NA NA NA NA M NA
Branch standard designs 071 142 178 199 209 217 425 Cooling Tower duty Manilla connection. Stainless steel / acid proof bolts. Extreme heavy duty design. Non-standard voltage or frequency, (special winding). Cast iron D-end shield (on aluminum motor). Corrosion protected stator and rotor core. NA P NA P M P M P M P M P S P S P S P S P S P S P NA NA M NA P NA NA M NA P NA P M NA P NA P M NA P R P M NA P R P M NA P P P M NA P P P M NA P P P M NA P P P M NA P P P M NA P P P M NA P
Cooling system 053 068 075 Metal fan cover. Light alloy metal fan Cooling method IC418 (without fan). M M R M M R M M P M M P M M P M M P S M NA S M NA S M NA S M NA S M NA S M NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
194 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code
1)
Variant
Frame size 71 80 90 100 112 132 160 180 200 225 250 280
Hazardous Environments 452 453 DIP/Ex tD acc. to ATEX directive 94/9/EC, T= 125 C, cat. 3D, IP 55 DIP/Ex tD acc. to ATEX directive 94/9/EC, T= 125 C, cat. 2D, IP 65 Heating elements 450 451 Heating element, 100-120V. Heating element, 200-240V. M M M M M M M M M M M M M M M M M M M M M M M M NA NA P P P P NA NA NA NA NA NA M M M M M M M M M M M M
Insulation system 014 405 406 Winding insulation class H. Special winding insulation for frequency converter supply. Winding for supply >690<=1000 Volts. NA NA NA NA NA NA R R P P P P R R R R P P P P P P P P P P P P P P P P P P P P
Mounting arrangements 007 008 009 047 048 066 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). IM 2101 foot/ange mounted, IEC ange, from IM 1001 (B34 from B3). IM 2001 foot/ange mounted, IEC ange, from IM 1001 (B35 from B3). IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). Modified for non-standard mounting position (please specify IM xxxx), (must be ordered for all mounting arrangements excluding IM B3 (1001), IM B5 (3001), IM B35 (2001), B34 (2101) & B14 (3601). 200 218 219 220 223 224 226 227 229 233 234 235 243 244 245 255 260 306
1)
NA M M M M M
NA M M M M M
NA M M M M M
NA M M M M M
NA M M M M M
NA M M M M M
M M M M NA M
M NA M NA NA M
M NA M NA NA M
M NA M NA NA M
M NA M NA NA M
M NA M NA NA M
Flange ring holder. Flange ring FT 85. Flange ring FT 100. Flange ring FF 100. Flange ring FF 115. Flange ring FT 115. Flange ring FF 130. Flange ring FT 130. Flange FT 130. Flange ring FF 165. Flange ring FT 165. Flange FF 165. Flange ring FF 215. Flange ring FT 215. Flange FF 215. Flange FF 265. Flange FT 115. IM 1001 foot mounted, from IM 3601 (B3 from B14).
M M M M M M M M NA M M NA NA NA NA NA NA M
M M M M M M M M NA M M NA NA NA NA NA NA M
M M M M M M M M NA M M M NA NA NA NA M M
M NA NA NA NA M M M M M M NA M M M NA NA M
M NA NA NA NA M M M M M M NA M M M NA NA M
M NA NA NA NA NA NA NA NA NA NA NA M M NA M NA M
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 195
Code
1)
Variant
Frame size 71 80 M M M M M M M M M 90 M M M M M M M M M 100 M M M M M M M M M 112 M M M M M M M M M 132 M M M M M M M M M 160 NA NA NA NA NA NA NA NA NA 180 NA NA NA NA NA NA NA NA NA 200 NA NA NA NA NA NA NA NA NA 225 NA NA NA NA NA NA NA NA NA 250 NA NA NA NA NA NA NA NA NA 280 NA NA NA NA NA NA NA NA NA
307 308 309 310 311 312 315 316 319 Painting 114 168
IM 2101 foot/flange mounted, IEC flange, from IM 3601 (B34 from B14). IM 2001 foot/flange mounted, IEC flange, from IM 3601 (B35 from B14). IM 1001 foot mounted, from IM 3001 (B3 from B5). IM 2101 foot/ange mounted, IEC ange, from IM 3001 (B34 from B5). IM 2001 foot/ange mounted, IEC ange, from IM 3001 (B35 from B5). IM 1001 foot mounted, from IM 2101 (B3 from B34). IM 2001 foot/flange mounted, IEC flange, from IM 2101 (B35 from B34). IM 1001 foot mounted, from IM 2001 (B3 from B35). IM 2101 foot/flange mounted, IEC flange, from IM 2001 (B34 from B35).
M M M M M M M M M
P NA
P NA
M P
M P
M P
M P
M NA
M NA
M NA
M NA
M NA
M NA
Protection 005 072 073 158 211 403 404 784 Metal protective roof, vertical motor, shaft down. Radial seal at D-end. Sealed against oil at D-end. Degree of protection IP 65. Weather protected, IP xx W Degree of protection IP 56. Degree of protection IP 56, without fan and fan cover. Gamma-seal at D-end. NA NA M M M M M M M M M M M M NA M NA M NA M M NA M NA M NA M M NA M P M P M M NA M P M P M M NA M P M P M M NA M M M P M M NA M NA M NA M M NA M NA M NA M M NA M NA M NA M M NA M NA M NA M M M M NA M NA M M NA M NA M NA
Rating & instruction plates 002 003 004 095 098 135 138 139 160 161 162 163 198
1)
Restamping voltage, frequency and output, continuous duty. Individual serial number. Additional text on std rating plate (max 12 digits on free text line). Restamping output (maintained voltage, frequency), intermittent duty. Stainless rating plate. Mounting of additional identification plate, stainless. Mounting of additional identification plate, aluminium. Additional identification plate delivered loose. Additional rating plate affixed. Additional rating plate delivered loose. Rating plate xed to stator. Frequency converter rating plate. Rating data according to quotation. Aluminum rating plate.
M M NA M M M M M P M S R S
M M NA M M M M M P M S R S
M M M M M M M M M M S R S
M M M M M M M M M M S R S
M M M M M M M M M M S R S
M M M M M M M M M M S R S
R S M R M NA NA M M M S M S
R S M R M NA NA M M M S M S
R S M R M NA NA M M M S M S
R S M R M NA NA M M M S M S
R S M R M NA NA M M M S M S
R S M R M NA NA M M M S M S
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
196 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code
1)
Variant
Frame size 71 80 90 100 112 132 160 180 200 225 250 280
Shaft & rotor 069 070 131 164 165 410 Two shaft extensions as per basic catalogue. One or two special shaft extensions, standard shaft material. Motor delivered with half key (Key not exceeding shaft diameter) Shaft extension with closed key-way. Shaft extension with open key-way. Stainless steel shaft (standard or non-standard design). Standards and Regulations 011 779 Fulfilling CSA Energy Efficiency Verification (code 010 included). SASO Export/Import Certificate (Saudi Arabia) NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA R R R R R R NA NA NA NA NA NA NA P P NA P P NA P P NA P P S P R S P R S P R S P R S P R S P R NA NA M M M M M M M M M M NA NA NA NA P P P P P P P P P R P R P R P R P R P R
Stator winding temperature sensors 121 122 123 124 125 127 321 322 323 325 327 435 436 437 439 440 441 Bimetal detectors, break type (NCC), (3 in series), 130 C, in stator winding. Bimetal detectors, break type (NCC), (3 in series), 150 C, in stator winding. Bimetal detectors, break type (NCC), (3 in series), 170 C, in stator winding. Bimetal detectors, break type (NCC), (3 in series), 140 C, in stator winding. Bimetal detectors, break type (NCC), (2x3 in series), 150 C, in stator winding. Bimetal detectors, break type (NCC), (3 in series, 130 C & 3 in series, 150 C), in stator winding. Bimetal detectors, closing type (NO), (3 in parallel), M 130 C, in stator winding. Bimetal detectors, closing type (NO), (3 in parallel), M 150 C, in stator winding. Bimetal detectors, closing type (NO), (3 in parallel), NA 170 C, in stator winding. Bimetal detectors, closing type (NO), (2x3 in parallel), 150 C, in stator winding. Bimetal detectors, closing type (NO), (3 in parallel, 130 C & 3 in parallel, 150 C), in stator winding. PTC - thermistors (3 in series), 130 C, in stator winding. PTC - thermistors (3 in series), 150 C, in stator winding. PTC - thermistors (3 in series), 170 C, in stator winding. PTC - thermistors (2x3 in series), 150 C, in stator winding. PTC - thermistors (3 in series, 110 C & 3 in series, NA 130 C), in stator winding. PTC - thermistors (3 in series, 130 C & 3 in series, NA 150 C), in stator winding.
1)
M M M NA NA NA
M M M NA NA NA M M NA NA NA M M M NA NA NA
M M M NA M M M M P P P M M P M P M
M M M NA M M M M P P P M M P M P M
M M M NA M M M M P M M M M M M P M
M M M NA M M M M P M M M M M M P M
M M M M M M R R R R R M S M M R M
M M M M M M R R R R R M S M M R M
M M M M M M R R R R R M S M M R M
M M M M M M R R R R R M S M M R M
M M M M M M R R R R R M S M M R M
M M M M M M R R R R R M S M M R M
NA NA M M M NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 197
Code
1)
Variant
Frame size 71 80 NA NA NA 90 P R R 100 P R R 112 M M R 132 M M R 160 M M M 180 M M M 200 M M M 225 M M M 250 M M M 280 M M M
PTC - thermistors (3 in series, 150 C & 3 in series, NA 170 C), in stator winding. Pt-100 2-wire in stator winding, 1 per phase Pt-100 2-wire in stator winding, 2 per phase NA NA
Terminal box 015 016 017 019 021 022 136 137 180 375 376 400 402 418 465 467 729 736 737 738 739 740 Testing 140 145 146 147 148 153 221 222 Test confirmation. Type test report from a catalogue motor, 400V 50Hz. Type test with report for one motor from specific delivery batch. Type test with report for motor from specific delivery batch, customer witnessed. Routine test report. Reduced test for classification society. Type test and multi-point load test with report for one motor from specific delivery batch. Torque/speed curve, type test and multi-point load test with report for one motor from specific delivery batch. 760
1)
Motor supplied in D connection. 9 terminals in terminal box Motor supplied in Y connection. Larger than standard terminal box. Terminal box LHS (seen from D-end). Cable entry LHS (seen from D-end).
M NA M NA NA NA
M NA M NA NA NA NA P NA M M NA NA NA NA NA NA M M NA NA NA
M P P NA NA NA P P NA M M NA NA NA NA NA NA M M NA NA NA
M P P NA NA NA P P NA M M NA NA R NA NA NA M M NA NA NA
M P NA NA NA NA P P NA M M NA NA R NA NA NA M M NA NA NA
M P NA NA NA NA P P NA M M NA NA R NA NA NA M M NA NA NA
M NA M NA NA S R R NA NA NA R NA M S P NA R R S S M
M NA M NA NA S R R NA NA NA R NA M S P NA R R S S M
M NA M M P R R R P NA NA NA P M S P M R R S M M
M NA M M P R R R P NA NA NA P M S P M R R S M M
M NA M M P R R R P NA NA NA P M S P M R R S M M
M NA M NA P R R R P NA NA NA P M S P M R R S P M
Extended cable connection, standard terminal box. NA Extended cable connection, low terminal box, Flying leads. Terminal box RHS (seen from D-end). Standard plastic cable gland Two standard plastic cable glands 4 x 90 degr turnable terminal box. Terminal box adapted for Al cables. Separate terminal box for auxiliaries, standard material. Terminal box on top. Lower than standard terminal box and rubber extended cable. Cable length 2m. Aluminum non-drilled flange for cable glands Standard cable gland Ex e acc. to EN-standards. Standard cable gland Ex e with clamping device acc. to EN-standards Prepared for metric cable glands. Prepared for metric cable glands according to DIN 42925, draft aug. 1999. Prepared for PG cable glands. NA NA NA NA M M NA NA NA M M NA NA NA P
M M M M M M M NA
M M M M M M M NA
M M M M M M M P
M M M M M M M P
M M M M M M M P
M M M M M M M P
M M M M M M M M
M M M M M M M M
M M M M M M M M
M M M M M M M M
M M M M M M M M
M M M M M M M M
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
198 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Code
1)
Variant
Frame size 71 80 M NA 90 P P 100 P P 112 P NA 132 P NA 160 M R 180 M R 200 M R 225 M R 250 M R 280 M R
762 763
Noise level test for one motor from specific delivery batch. Noise spectrum test for one motor from specific delivery batch.
M NA
Variable speed drives 470 476 477 574 577 578 Prepared for hollow shaft pulse tacho (L&L equivalent). Separate motor cooling (fan axial, N-end) and 1024 pulse tacho (L&L 861007455-1024). Separate motor cooling (fan axial, N-end) and 2048 pulse tacho (L&L 861007455-2048). Separate motor cooling (fan axial, N-end) and prepared for hollow shaft tacho (L&L 503). Separate motor cooling (fan axial, N-end) and 2048 pulse tacho (L&L 503). Separate motor cooling, IP 44, 400V, 50Hz (fan axial, N-end) and prepared for hollow shaft tacho (L&L 503). 580 581 661 662 704 Separate motor cooling, IP 44, 400V, 50Hz (fan axial, N-end) and 1024 pulse tacho (L&L 503). Separate motor cooling, IP 44, 400V, 50Hz (fan axial, N-end) and 2048 pulse tacho (L&L 503). 1024 Pulse tacho mounted, Hohner series 59, 11-30V 2048 Pulse tacho mounted, Hohner series 59, 11-30V EMC cable gland. Terminals for Y/ start at both speeds (two speed windings). 118 Terminals for Y/ start at high speed (two speed windings).
1)
R R R R R NA
R R R R R NA
R R R NA NA NA
R R R NA NA NA
R R R NA NA NA
R P R NA NA NA
M M M M M M
M M M M M M
M M M M M M
M M M M M M
M M M M M M
M M M M M M
NA NA R R NA
NA NA R R NA
NA NA P P M
NA NA P P M
NA R P P M
NA R P P M
M M NA NA M
M M NA NA M
M M NA NA M
M M NA NA M
M M NA NA M
M M NA NA M
Y/ starting 117 NA P NA P P P P P P P P P NA NA NA NA NA NA NA NA NA NA NA NA
S = Included as standard P = New manufacture only M = On modification of a stocked motor; or on new manufacture, the number of number per order may be limited. R = On request NA = Not applicable.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 199
HD
M000267 M000268
PN
H K A
B B
M000272
M000269
D GA
45
M000271
45
Sizes 71 to 200 Sizes 225 to 355 Protective roof, variant code 005
Motor size
IM 1001, IM B3 AND IM 3001, IM B5 D GA F E poles 2 4-8 poles 2 4-8 16 21.5 27 31 31 41 45 51.5 59 59 64 69 69 69 62.5 62.5 62.5 85 85 16 21.5 27 31 31 41 45 51.5 59 64 69 79.5 85 95 90 90 90 126 106 poles 2 4-8 5 6 8 8 8 10 12 14 16 16 18 18 18 18 20 20 20 22 22 5 6 8 8 8 10 12 14 16 18 18 20 22 25 28 28 28 28 28 poles 2 4-8 30 40 50 60 60 80 110 110 110 110 140 140 140 140 140 140 140 170 170 30 40 50 60 60 80 110 110 110 140 140 140 170 170 210 210 210 210 210
L max poles 2 4-8 264 321 357 381 403 533 808 826 774 841 875 1088 1174 1285 1409 1514 1764 1851 1851 264 321 357 381 403 533 808 826 774 871 875 1088 1204 1315 1479 1584 1834 1891 1891
IM 1001, IM B3 A B B C
HD
IM 3001, IM B5 M N P S
71 80 90 100 112 132 160 180 200 225 250 280 315 SM_ 315 ML_ 355 SM_ 355 ML_ 355 LK_ 400 L_ 400 LK_
14 19 24 28 28 38 42 48 55 55 60 65 65 65 70 70 70 80 80
112 125 140 160 190 216 254 279 318 356 406 457 508 508 610 610 610 710 686
90 100 100 140 140 140 210 241 267 286 311 368 406 457 500 560 710 900 710
125 178 254 279 305 311 349 419 457 508 560 630 900 1000 800
45 50 56 63 70 89 108 121 133 149 168 190 216 216 254 254 254 224 280
178 195 219 247 259 300 499 539 594 641 704 777 847 847 974 974 974 1061 1061
130 165 165 215 215 265 160 180 200 225 250 280 315 315 355 355 355 400 400
110 130 130 180 180 230 300 300 350 400 500 500 600 600 740 740 740 940 740
160 200 200 250 250 300 250 250 300 350 450 450 550 550 680 680 680 880 680
10 12 12 15 15 15 350 350 400 450 550 550 660 660 800 800 800 1000 800
272.5 331 368.5 395 417 551.5 328 359 414 462 506 555 624 624 720 720 720 810 810
272.5 331 368.5 395 417 551.5 756 756 844 921 965 1190 1290 1401 1476 1528 1633 1860 1860
M000231
M000270
M000230
360 430 505 505 590 756 756 844 951 965 1190 1320 1431 1546 1703 1703 1900 1900
LA 8 8 10 10 10 12
S M6 M6 M8 M8 M8 M10
S M6 M6 M8 M8 M8 M10
A, B D, DA F, FA H N C, CA
0,8 ISO k6 < 50mm ISO m6 > 50mm ISO h9 -0.5 ISO j6 0.8
Above table gives the main dimensions in mm. For detailed drawings please see our web-pages www.abb.com/motors&generators or contact ABB.
200 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
PN
M000268
B B
M000267
H K A
Shaft extension
Flanges
M000269
45
GA
45
Sizes 90 to 200 Sizes 225 to 280
Motor size
IM 1001. IM B3 AND IM 3001. IM B5 D GA F poles poles poles 2 4-8 2 4-8 2 4-8 M3AAD 71 14 14 16 16 5 5 80 19 19 21.5 21.5 6 6 90 S 24 24 27 27 8 8 90 L 24 24 27 27 8 8 90 LD 24 24 27 27 8 8 M3AAD 100 28 28 31 31 8 8 112 28 28 31 31 8 8 38 41 41 10 10 132 1) 38 38 41 41 10 10 132 2) 38 M3AA 160 3) 42 42 45 45 12 12 42 45 45 12 12 160 4) 42 180 48 48 51.5 51.5 14 14 200 55 55 59 59 16 16 225 55 60 59 64 16 18 250 60 65 64 69 18 18 280 65 75 69 79.5 18 20
All types except 2). SM_.
IM 1001. IM B3 E poles 2 30 40 50 50 50 60 60 80 80 110 110 110 110 110 140 140 L max poles 2 240 265.5 284.5 309.5 331.5 351 393 447 550 584 681 726 821 850 884 884 O 4-8 240 265.5 284.5 309.5 331.5 351 393 447 550 584 681 726 821 880 884 884
5)
A 112 125 140 140 140 160 190 216 216 254 254 279 318 356 406 457
B 90 100 100 125 125 140 140 140 140 210 210 241 267 286 311 368
B' 178 178 254 254 279 305 311 349 419
HD 180 193.5 217 217 217 237 249 295.5 321 370 370 405 532 579 627 627
K 7 10 10 10 10 12 12 12 12 15 15 15 18 18 22 24
H 71 80 90 90 90 100 112 132 132 160 160 180 200 225 250 280
M000272
M000271
IM 3001. IM B5 M 130 165 165 165 165 215 215 265 265 300 300 300 350 400 500 500 N 110 130 130 130 130 180 180 230 230 250 250 250 300 350 450 450 P 160 200 200 200 200 250 250 300 300 350 350 350 400 450 550 550 S 10 12 12 12 12 15 15 14.5 14.5 19 19 19 19 19 19 19
20 25 30 30 30 35 35 50 50 50 50 55 55 60 65 65
1) 2) 3) 4) 5)
MLA-2 and MLB-2; MLA-4 poles; MLA-6 poles; MLA-8 and MLB-8 poles. Remaining variants, i.e. MLC-2, MLD-2 and MLE-2 poles; MLB-4, MLC-4 and MLD-4 poles; MLC-8 poles. 0 = Minimum free free distance for cooling
IM 3601, IM B14
Motor size 71 80 90 100 112 132
Tolerances:
LA
A, B D, DA F, FA H N C, CA
0,8 ISO k6 < 50mm ISO m6 > 50mm ISO h9 -0.5 ISO j6 0.8
11 11 13 14 14 18
M6 M6 M8 M8 M8 M10
Above table gives the main dimensions in mm. For detailed drawings please see our web-pages www.abb.com/motors&generators or contact ABB.
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 201
M000270
HD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Stator frame Endshield, D-end Screws for endshield, D-end Endshield, N-end Screws for endshield, N-end Rotor with shaft Key, D-end Terminal box Terminal board Intermediate flange Screws for terminal box cover Outer bearing cover, D-end Valve disc with labyrinth seal, D-end; standard in 2-pole motors (V-ring in 4-8 pole) Bearing, D-end Inner bearing cover, D-end Screws for bearing cover, D-end
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Outer bearing cover, N-end Seal, N-end Wave spring Valve disc, N-end Bearing, N-end Inner bearing cover, N-end Screws for bearing cover, N-end Fan Fan cover Screws for fan cover Rating plate Regreasing plate Grease nipple, D-end Grease nipple, N-end SPM nipple, D-end SPM nipple, N-end
202 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
M000220
Certicate examples
M000730
2(2)
2011-06-22 Certificates: 3-phase induction motors, series M2GP, M3JP, M3KP, M3GP, M3HP, M3LP
Motor type, IEC frame size M3JP/M3KP 80 M3JP/M3KP 90 M3JP/M3KP 100-112 M3JP/M3KP 132 M3JP/M3KP 160 M3JP/M3KP 180 M3JP/M3KP 160 Gen.H M3JP/M3KP 180 Gen.H M3JP/M3KP 200 M3JP/M3KP 225 M3JP/M3KP 250 M3JP/M3KP 280 M3JP/M3KP 315 M3JP/M3KP 355 M3JP/M3KP 400 M3HP 80-90 M3HP 100-112 M3HP 132 M3HP 160 M3HP 180 M3HP 160 Gen.H M3HP 180 Gen.H M3HP 200 M3HP 225 M3HP 250 M3HP 280 M3HP 315 M3HP 355 M3HP 400 M2GP 71-250 M3GP 80 - 400 M3GP 160 - 180 Gen.H M3GP/M3LP 450 M3GP 160 180 Gen.H IP 65 M3GP 160 180 Gen.H M3GP/M3LP 450 M2GP 71-250 M3GP 80-400 LCIE 09 ATEX 1010 * LCIE 06 ATEX 6088 LCIE 05 ATEX 6160 LCIE 06 ATEX 6089 2009 2006 2005 2006 Certification number LCIE 04 ATEX 6150 LCIE 04 ATEX 6151 LCIE 04 ATEX 6152 LCIE 04 ATEX 6061 LCIE 00 ATEX 6023 LCIE 00 ATEX 6028 LCIE 09 ATEX 3004X LCIE 09 ATEX 3005X LCIE 00 ATEX 6027 LCIE 00 ATEX 6029 LCIE 00 ATEX 6030 LCIE 01 ATEX 6078 LCIE 01 ATEX 6079 LCIE 03 ATEX 6060 LCIE 04 ATEX 6087 LCIE 06 ATEX 6047 LCIE 06 ATEX 6048 LCIE 06 ATEX 6049 LCIE 01 ATEX 6015 LCIE 01 ATEX 6021 LCIE 09 ATEX 3022 LCIE 09 ATEX 3023 LCIE 01 ATEX 6022 LCIE 01 ATEX 6023 LCIE 01 ATEX 6024 LCIE 02 ATEX 6071 LCIE 02 ATEX 6072 LCIE 03 ATEX 6022 LCIE 04 ATEX 6013 LCIE 05 ATEX 6160 LCIE 06 ATEX 6089 LCIE 09 ATEX 1010 * LCIE 06 ATEX 6088 LCIE 09 ATEX 3016 Year of CE-marking 2004 2004 2004 2004 2000 2000 2009 2009 2000 2000 2000 2001 2001 2003 2004 2006 2006 2006 2001 2001 2009 2009 2001 2001 2001 2002 2002 2003 2004 2005 2006 2009 2006 2009
EC Declaration of Conformity
The Manufacturer: ABB Oy Motors Motors and Generators P.O. Box 633 Strmbergin puistotie 5A FIN - 65101 Vaasa, Finland
hereby declares that the products: 3-phase induction motors, series M2GP, M3JP, M3JC, M3KP, M3KC, M3GP, M3HP and M3LP; as listed on page 2 in this document, fulfill provisions of the relevant Council Directives:
rd
In addition: II 2 D Ex tD A21 / IP 65 or II 3 D Ex tD A22 / IP 55, IP65 (3D not for M3JP/KP160-180 Gen.H)
Increased safety
- that the state of the art of these standards do not modify the result of the assessment carried out by LCIE which issued the EC type examination certificates according to former editions of the standard series. - that listed motors conform to the requirements of annex II of the directive 94/9/EC clause 1.2.7 by applying the standards series EN 60034. Directive 2009/125/EC (EuP of 21st October 2009) by fulfilling the requirements of the standard IEC 60034-30: 2008 Ed 1 in respect of the efficiency class. Note: When installing motors for converter supply applications additional requirements must be respected regarding the motor as well as the installation, as described in the appropriate dedicated addendum.
Signed by
Non-sparking II 3G Ex nA II T2 -T3
Title Date
ABB Oy
Motors and Generators Postal address P.O. Box 633 FI-65101 Vaasa FINLAND Visiting Address Strmbergin Puistotie 5 A FI-65320 Vaasa FINLAND Telephone +358 10 22 11 Telefax +358 10 22 47372 Internet www.abb.fi e-mail: first name.last name @fi.abb.com Business Identity Code: 0763403-0 Domicile: Helsinki
M000725-1a
1) 2)
Notified Body ( ExNB ): LCIE (0081) ; Av. Du Gnral Leclerc. 33, 92266 Fontenay-aux-Roses, France *) Voluntary Type Examination Certificate for equipment category 3
3GZF500930-988
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 203
M000725-2a
M000740
Dust ignition protection cast iron motors in brief, basic design 2D and 3D
Motor size Stator Material 71 80 90 100 112 132 160 180
C3 medium according to ISO/EN 12944-5 Cast iron, EN-GLJ-150 or better, integrated with stator Forged steel, detachable feet
Material
Paint colour shade Corrosion class Bearings D-end 2-8 pole N-end 2- 8 pole Axially-locked bearings Bearing seal Lubrication SPM-nipples Rating plate Terminal box Material Frame material Inner bearing cover
C3 medium according to ISO/EN 12944-5 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6208-2Z/C3 6309/C3 6310/C3
6202-2Z/C3
6203-2Z/C3
6204-2Z/C3
6205-2Z/C3
6208-2Z/C3
6309/C3
6310/C3
Gamma ring Permanent grease lubrication. Stainless steel Cast iron, EN-GLJ-150 or better Cast iron, EN-GJL-200 or better Cover material Cast iron, EN-GLJ-150 or better Cast iron, EN-GJL-200 or better Screws Steel 8.8, zinc electroplated and chromated 2xM16 2 x M25 2 x M32 2 x M40 x 1.5 Regreasable bearings As standard
Connections
6 terminals for connection with cable lugs (not included) Polypropylene. Reinforced with glass bre. Steel Blue, Munsell 8B 4.5/3.25 Hot dip galvanized steel
Stator winding
Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method
Material
On request
204 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Dust ignition protection cast iron motors in brief, basic design 2D and 3D
Motor size Stator Material Paint colour shade Corrosion class Feet Bearing end shields Material Paint colour shade Corrosion class Bearings D-end 2-pole 4-12 -pole N-end 2-pole 4-12 -pole Axially-locked bearings Bearing seal Lubrication SPM-nipples Rating plate Terminal box Material Frame material Cover material Cover screws material Connections Cable entries Terminals Fan Fan cover Material Material Paint colour shade Corrosion class Stator winding Material Insulation Winding protection Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method Optional Material Inner bearing cover 200 225 250 280 315 355 400 Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Cast iron, EN-GJL-200 or better, integrated with stator Cast iron, EN-GJL-200 or better Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 6312M/C3 6312/C3 6310M/C3 6310/C3 6313M/C3 6313/C3 6312M/C3 6312/C3 6315M/C3 6315/C3 6313M/C3 6313/C3 6316/C3 6316/C3 6319/C3 6319/C3 6316M/C3 6322/C3 6316M/C3 6317/C3 6324/C3 6317/C3 6319/C3
As standard, locked at D-end Gamma ring Regreasable bearings As standard Stainless steel Cast iron, EN-GJL-200 or better Cast iron, EN-GJL-200 or better Steel 8.8, zinc electroplated and chromated 2 x M50 x 1.5 2 x M63 x 1.5 Refer to page 163. Optional As standard V-ring or labyrinth seal
6 terminals for connection with cable lugs (not included) Aluminum Hot dip galvanized steel Blue, Munsell 8B 4.5/3.25 C3 medium according to ISO/EN 12944-5 Copper Insulation class F 3 pcs thermistors Pressure die-cast aluminum Half key balancing Closed key way 25 W As standard As standard IP 55 or IP 65 IC 411 60 W Open key away 120 W
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 205
100
112
132
D-end with inner bearing cover V-ring V-ring Permanently lubricated bearings. Grease temperature range -40 to +160 C.
Lubrication Terminal box Material Surface treatment Screws Connections Knock-out openings Terminal box
Die-cast aluminum alloy, base integrated with stator. Similar to stator. Steel 8.8, zinc electroplated. 2 x (M20 + M25) Screw terminal. 6 terminals. 2 x (M20 + M25) Cable lugs. 6 terminals.
Max Cu-area, mm2 Fan Fan cover Stator winding Material Material Material Insulation class Winding protection Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method Material
6 Aluminum fan Steel Copper Insulation class F PTC- thermistors, 150 C Die-cast aluminum Half key balancing Closed key way 25 W Not included, drain holes sealed on delivery. As standard. IP 65 IC 411
10
206 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Bearing seal
D-end N-end
V-ring Labyrinth seal Permanently lubricated bearings. Grease temperature range -40 to +160 C
Lubrication Terminal box Material Surface treatment Screws Connections Knock-out openings
Die-cast aluminum alloy, base integrated with stator Similar to stator Steel 8.8, zinc electroplated. 2 x (M20 + M20) 2 x (M20 + M25) 2 x (M40 + M32+ M12)2)
Terminal box
Max Cu-area, mm2 Fan Fan cover Stator winding Material Material Material Insulation class Winding protection Rotor winding Balancing Key ways Heating elements Drain holes External earthing bolt Enclosure Cooling method
1) 2)
4 Aluminum fan Steel Copper Insulation class F Optional Die-cast aluminum Half key balancing Closed key way 8W 25 W
10 1) 32 2)
Material
Drain holes with closable plastic plugs. Closed on delivery. As standard IP 55 IC 411
2)
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 207
Cast iron, EN-GJL-200 or better Munsell blue 8B 4.5/3.25 Two-pack epoxy paint 100 m 6309-2Z/C3 6310-2Z/C3 6312-2Z/C3 6313-2Z/C3 6315-2Z/C3 6315/C3 6316/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 6213-2Z/C3 6213/C3
M10 70
Insulation class F. Temperature rise class B, unless otherwise stated. 3 pcs PTC-thermistors, 150 C Die-cast aluminum Half key balancing Closed keyway 25 W 50 W
Material
208 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
Flameproof motors
Type of protection: Ex d IIB/IIC T4, Ex de, IIB/IIC T4 Features: 50/60 Hz, 2 - 18 poles, VSD application, acc. to Atex Directive and IEC standards Motor type Ribs cooled Tubes cooled IEC frame size 355 - 500 500 - 900 Output kW 100 - 1200 kW 800 - 8000 kW
Pressurized motors
Type of protection: Ex px (e) and Ex pz (e); Temperature classes T1-T4, Gas groups A, B anc C Features: 50/60 Hz, 2-24 poles, VSD applications, acc. to ATEX Directive and IEC standards
Non-sparking motors
Type of protection: Ex nA, T1-T4, Gas groups A,B and C Features: 50/60 Hz, 2-24 poles, VSD applications, acc. to ATEX Directive and IEC standards, CSA/US certified Motor type Induction motors Synchronous motors IEC frame size 315 - 1000 710 - 2500 Output kW up to 23 MW (31000 HP) up to 65 MW (87000 HP)
More information for these motors can be found from web-pages: www.abb.com/motors&generators
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 209
Total offer of motors, generators and mechanical power transmission products with a complete portfolio of services
ABB is the leading manufacturer of low, medium and high voltage motors and generators, mechanical power transmission products with an offering of a complete portfolio of services. Our in-depth knowledge of virtually every type of industrial processing ensures we always specify the best solution for your needs.
Cast iron frame (TEFC) Air to air cooled (TEAAC) motors Motors and generators for explosive atmospheres IEC and NEMA motors and generators, for all protection types Synchronous motors Synchronous generators Synchronous generators for diesel and gas engines Synchronous generators for steam and gas turbines Wind power generators Generators for small hydro Other motors and generators Brake motors DC motors and generators Gear motors Marine motors and generators Single phase motors Motors for high ambient temperatures
Permanent magnet motors and generators High speed motors Smoke extraction motors Wash down motors Water cooled motors Generator sets Roller table motors Servo motors Traction motors Life cycle services Installation and commissioning Service contracts Preventive maintenance Spare parts Diagnosis Repair and refurbishment Site survey and overhaul Replacement motors and generators Technical support and consulting Trainings Mechanical power transmission components, bearings, gears
Low and high voltage IEC induction motors Process performance motors General performance motors High voltage cast iron motors Induction modular motors Slip-ring modular motors Synchronous reluctance motors Low and medium voltage NEMA motors Steel frame open drip proof (ODP) motors Weather protected, water cooled, fan ventilated
210 LV Motors for explosive atmospheres EN 03-2013 / ABB Motors and Generators
ABB Motors and Generators / LV Motors for explosive atmospheres EN 03-2013 211
Contact us
www.abb.com/motors&generators
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Ltd does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB Ltd. Copyright 2013 ABB. All rights reserved.
9AKK104006 EN 03-2013