Professional Documents
Culture Documents
Customer Details:
Ref.No.: Organization Name: Work Address: Office Adress: Date:
Fax:
1.Generation
1 Chiller Type Chiller 1 VAM Reciprocating Screw Scroll Centrifugal Steam operated Direct fired Hot water Single effect Double effect Chiller 2 VAM Reciprocating Screw Scroll Centrifugal Steam operated Direct fired Hot water Single effect Double effect Chiller 3 VAM Reciprocating Screw Scroll Centrifugal Steam operated Direct fired Hot water Single effect Double effect
VAM Type
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
VAM Effect Chiller Make Model Year of Installation Name of Refrigerant used Capacity(TR) & Design working Temp.(oC) range Status Average chiller load (TR) Peak chiller load (TR) Present inlet chilled water / brine temp., oC Present outlet chilled water / brine temp., oC Condenser water inlet let & outlet temperature (oC) Avg. Operating (Hrs/day) Annual working days In case of Electric operated chiller - Design gas discharge & suction Pressure (Kg/cm2g) In case of Electric operated chiller - Actual gas discharge & Suction Pressure (Kg/cm2g) Design chilled water flow & Pressure drop across evaporator / absorber Actual chilled water flow / brine & Pressure drop across evaporator / absorber Design condenser water flow & Pressure drop across condenser Actual condenser water flow & Pressure drop across condenser
Working StandBy
Working StandBy
Working StandBy
THERMAX CUDS
Fuel/Steam/Electricity used
16 Driving Energy used like Fuel/Steam/Electricity & its consumption In case of steam operated VAM, Steam inlet pressure & temperature (oC) Condensate outlet quantity, M3/hr. & temperature (oC) In case of direct fired VAM - Type & G.C.V. of fuel (Kcal/Kg) In case of direct fired VAM -N.C.V. of fuel (Kcal/Kg) Landed Price of Energy, Rs. / kg or Rs. / unit Average Energy consumption per day with unit Energy Bill/annum (Rs.) Flow Meter available on water / brine Size & Type In case of direct fired VAM -Type of Burner In case of direct fired VAM - Burner Make In case of direct fired VAM -Inlet / Return Fuel Pressure (Kg/cm2g) Fuel temperature at inlet to burner (0C) Fuel heating Steam Elect Heater Steam Elect Heater Steam Elect Heater Yes No
17
18 19 20 21 22 23 24 25 26
Cooling Tower
27 Type Make Nos. Status Design capacity, TR Design WBT Design DBT Design water flow Design inlet water temperature Design outlet water temperature Actual inlet water temperature Actual outlet water temperature Actual water flow Working StandBy Working StandBy Working StandBy
27
28
29
30
utilization
2.Distribution
1 2 3 Flow Meter available Main header size,mm Any Reccomendation Yes No Type & Size :
3.Utilization
1 2 3 4 5 6 7 8
Production capacity
1 Unit/Equipment/plant Chilled water / Brine tapping size,mm Supply Pressure,kg/cm2(g) Chilled Water /brine temp. required,0C Process temp. required,0C Manual Temperature control Heat load in terms of TR Automatic Manual Automatic Manual Automatic 2 3
Benchmark:
4 5
Manual Automatic
Manual Automatic
Chilled water / brine circulation rate m3/hr required 9 Operational hrs. Batch working 10 Nos. of equipments. 11 No.of batches per day 12 Batch size 13 Temperature rise/fall 14 Specific heat of material 15 Chilled water / brine ON time, hrs
Page 3 of 3