Three Phase Measurement System ( Star & Delta )

Salient Features :

Model - 9501

Adtron's Three Phase Measurement System is a self contained, stand - alone unit useful in the study of measurement of various paraments in three phase star and delta configuration. The unit consists of low voltage isolated, protected 3 phase supply with full instrumentation and three variable R, L and C loads. The unit is divided into three parts namely 3phase Measurement panel and 3phase RLC load Panel. The entire unit is housed in elegant Powder coated matel cabinet with a well spread intelligently designed layout Three Phase Supply Panel : This panel consists of three single phase transformers, each with two secondary windings, provide isolation and voltage reduction and enable star, delta and other connection, the supply input lives are protected by froms and circuit breakers. Circuit connections are made through colour coded 4mm binding posts Technical Specifications : 1 Supply Input : 1 Outputs : 415V three phase supply. Primary windings are star connected Six secondary windings, two per phase, of 60V / 2.5A each winding

Winding produce 60V/120V when connected delta or star respectively


1 Power

Switching
1 Supply

The phase supply is switched ON / OFF using a 3 phase MCB ( Maintenance Circuit Breaker ) The presence of three phase supply on panel is indicated by 3 lamps, each for R, Y, & B phase The input and output supply lines are protected by fuses

Indicator
1 Circuit

Protection : Connections :
1 Supply Input

Connection :

Three Phase with neutral & earth. An internal screw terminal is provided for this purpose. Connections to supply outputs and busbars are by 4 mm colour coded binding post

Three Phase Measurement Panel : This panel consists of three measuring facilities in one compact unit. Individual lines or phase voltages and their associated currents can be easily identified together with the 3 power factor. Two wattmeters are provided for 3 power measurement. The busbars, with colour coded binding posts, connects to the supply at one end and the load at other end and clearly Illustrates the circuit metering.

Instruments : 1 1 1 1 1 1 3 x Moving Coil Voltmeter with ranges 0 - 300V AC 3 x Moving Coil ammeters 0 - 5A AC 2 x 1 ph wattmeter with switchable ranges of 300W or 600W maximum rating 240V AC 5A 1 x 1 ph power factor meter for balanced loads PF range 0.5 lead to 0.5 lag Maximum rating 240VAC 5A All meters used are of the industry type with front size 96 x 96 mm Connections : Colour coded 4mm finding posts Three Phase R, L, C Load Panel : This panel consists of three identical individual load banks, each consisting of variable R, L & C components in steps. The three banks are match the circuitry of the other units Three Individual Load Banks each Consisting of : 1 1 1 1 Variable resistance in steps of 20 ohm upto 100 ohm ( i.e. 5 resistors of 20 ohm ) Variable inductors in steps of 100 mH 2A upto 300 mH ( i.e.3 indicators of 100mH ) Variables Capacitance in steps of 10 microF upto 50 microF ( i.e. 2 Capacitors of microF and a one of 10 microF ) Connections : 4 mm Colour Coded finding posts