You are on page 1of 31

Kuhnke Technical Data

The following page(s) are extracted from multi-page Kuhnke product catalogs or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogs, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files.

Contact Details
Kuhnke sales and service in North America Ellis/Kuhnke Controls 26 West Highland Avenue Atlantic Highlands New Jersey 07716 USA T: 800-221-0714 T: 732-291-3334 F: 732-291-8154 Email: sales@kuhnkeusa.com

Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.

HochleistungsHubmagnete RM, URM Heavy Duty Solenoids Series RM, URM

Hochleistungs-Hubmagnete Geschlossene Bauweise


Technische Beschreibung/ Vorzugstypen
Typ RM einfachwirkend Typ URM umkehrwirkend Die Typen RM und URM sind Hochleistungshubmagnete in geschlossener Bauweise. Diese Ausfhrungen sind bevorzugt dort einzusetzen, wo hchste Lebensdauer gefordert wird. Durch eine beidseitige wartungsfreie Ankerlagerung wird diese Forderung erfllt. Sie knnen in beliebiger Einbaulage montiert werden. Die Spulenspannung wird in der Regel in Gleichspannung ausgefhrt (Wechselspannung auf Anfrage). Neben den Standardtypen steht eine Vielzahl von Sonderhubmagneten zur Verfgung (siehe Beispiele Seite 37-39).

Heavy Duty Linear Solenoids Fully Encapsulated Design


Technical description/ Preferred types
Series RM single acting, series URM two directional Series RM and URM heavy duty solenoids are fully enclosed. These specifications are designed for maximum durability, this being ensured by service-free armature bearing on both sides. These solenoids can be mounted at any angle. The coil voltage is usually designed for DC (AC on request). Apart from the standard models we offer you a multitude of custom-made linear solenoids (see examples on pages 37-39).

O-F RR D H W %E 070 C100 M R 4VD

O-F RO D H E W 070 C100% M R 4VD

-F OO B W-O ED 070 C100% M R 4VD

R-F RO D O E W 070 C100% M R 4VD

Magnet Hauptkatalog

104

Main catalogue

Hochleistungs-Hubmagnete Geschlossene Bauweise


Technische Beschreibung/ Vorzugstypen
RM RM Vorzugstypen Hochleistungs-Hubmagnete RM RM RM RM * W = waagerechte Kennlinie 20 32 40 050 070 100 W*-OBOO W*-OBOO W*-OBOO F F F F F F 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC

Heavy Duty Linear Solenoids Fully Encapsulated Design


Technical description/ Preferred types
100 % ED 100 % ED 100 % ED 100 % ED 100 % ED 100 % ED * W = horizontal characteristics Preferred types Heavy duty linear solenoids

Die obenstehenden Hochleistungs-Hubmagnete Typ RM werden als Vorzugstypen lagermig gefhrt, damit Sie einen schnellen und preisgnstigen Zugriff fr Ihre Versuche haben. Die Vorzugstypen sind in kleinen Stckzahlen (Zwischenverkauf vorbehalten) innerhalb einer Woche lieferbar. Sie sind ausgelegt fr 24 V DC und 100 % ED. Bei Verwendung einer verstellbaren Spannungsquelle kann der Magnet ber die Nennspannung hinaus betrieben werden, um die fr die Bettigung erforderliche Kraft zu erreichen. Beachten Sie hierbei bitte, da bei lngerem Betrieb an erhhter Betriebsspannung diese Magnete berhitzt werden, wenn nicht ausreichende Pausen bei einer max. Spieldauer (Einschaltzeit + Ausschaltzeit) von 5 Minuten eingehalten werden. Zu Ihrer Information hier der mathematische Zusammenhang: U= UN
2.162

The heavy duty solenoids listed in the table are preferred types and are always in stock, enabling you to have them delivered quickly and at a competitive price for your tests. The preferred types can be delivered within a week (in small numbers) conditional to no resale. They are designed to operate at 24 V DC and 100 % ED.

If an adjustable voltage source is used, the solenoid can be operated at a higher voltage than that given in the rating, in order to obtain the required power.

However, these solenoids are subject to overheating during long term use with increased voltage, unless sufficiently long intervals and a maximal operating time (switch on time + switch off time) of 5 min are observed.

U= ED 100

UN
2.162

ED 100

U = Betriebsspannung (Anwender) UN = Nennspannung bzw. Standardspannung 24 V DC ED = relative Einschaltdauer (%) Zur Ermittlung der fr Ihren Anwendungsfall erforderlichen Kraft ist der Spulenstrom zu messen. Die genaue Festlegung der Spule erfolgt in unserer Entwicklungsabteilung: Geben Sie uns bitte hierzu den Magnetspulenstrom an, unter Bercksichtigung der geforderten max. Einschaltdauer.

U = applied operating voltage UN = rated voltage or standard voltage 24 V DC ED = relative duty cycle (%) In order to calculate the power required in your case, the coil current has to be measured. The exact determination of the duty cycle is made in our development laboratories. We would therefore ask you to supply us with the value for coil current taking into consideration the max. duty cycle requested.

Magnet Hauptkatalog

105

Main catalogue

Hochleistungs-Hubmagnet RM 13
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)

Heavy Duty Linear Solenoid RM 13


Thrust and pull type
13 13 F 24 100 % ED F 24 V DC 100 % ED Order specifications Linear solenoid Design type Coil terminals Flying leads (10 cm standard length) Nominal voltage (standard voltage)1) Perm. duty cycle under air cooled conditions (LK)
1)

RM RM

Die Magnete sind auf Anfrage bis 60 V DC lieferbar

Other voltages are available on request up to 60 V DC

Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

ca. 25 g ca. 4 g 24 V DC 10 cm B (Tgrenz = 130 C)

Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

appr. 25 g appr. 4 g 24 V DC 10 cm B (max. permissible temperature = 130 C)

Isolationsgruppe nach: VDE 0110 B 75 Prfspannung: 600 V (eff) In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
1,5 5 2 5 2

Insulation group according to: VDE 0110 B 75 Test voltage: 600 V (eff) Return spring optional.

Mae im bestromten Zustand > Hubrichtung

13

M6

2,8 Dimensions given with armature in fully home position > Direction of stroke 5 43,3
2)

3 8 9

34 50
+1

6+0,5

Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20

% W

100 2,9

50 5,4

25 10,1

% W

Perm. duty cycle (ED)2) Nominal coil power P 20

2) Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)

If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

10 8 5 F [N]

%ED

Kraft-Weg-Diagramm F = f (s)
1

Force vs. Stroke diagramm F = f (s)

25 0,5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 50 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position

0,2 0,1

100 0 1 2 3 4 5 S [mm] 6

Magnet Hauptkatalog

106

Main catalogue

Hochleistungs-Hubmagnet RM 20
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Steckhlsenanschlu 2,8 DIN 46247 Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)

Heavy Duty Linear Solenoid RM 20


Thrust and pull type
20 20 F M 24 100 % ED F 24 V DC 100 % ED Order specifications Linear solenoid Design type Coil terminals Flying leads (10 cm standard length) Terminal box (2.8 DIN 46247) Nominal voltage (standard voltage)1) Perm. duty cycle under air cooled conditions (LK)
1)

RM RM

Die Magnete sind auf Anfrage bis 60 V DC lieferbar

Other voltages are available on request up to 60 V DC

Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

ca. 60 g ca. 12 g 24 V DC 10 cm B (Tgrenz = 130 C)

Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

appr. 60 g appr. 12 g 24 V DC 10 cm B (max. permissible temperature = 130 C)

Isolationsgruppe nach: VDE 0110 C 300 Prfspannung: 800 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
M3 M3

Insulation group according to: VDE 0110 C 300 Test voltage: 800 V (eff) Service-free DU armature bearing for maximum durability. Return spring optional.

Mae im bestromten Zustand > Hubrichtung Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20 Anzugszeit (ED)
2)

SW14

M6

8 7 28 66,5 % W ms 100 3,9 11 45 8

2 8

8 12

12 16 20 15 21 5 59 5
2)

Dimensions given with armature in fully home position > Direction of stroke % W ms Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)

25 13,5

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) %ED

If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

100 50 F [N] 20

Force vs. Stroke diagramm F = f (s)


5 15 25 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at 45 operating temperature 100 stroke s = 0 corresponds to armature in fully home position

Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand

2 1

2 S [mm]

Magnet Hauptkatalog

107

Main catalogue

Hochleistungs-Hubmagnet RM 26
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)

Heavy Duty Linear Solenoid RM 26


Thrust and pull type
26 26 F 24 100 % ED F 24 V DC 100 % ED Order specifications Linear solenoid Design type Coil terminals Flying leads (10 cm standard length) Nominal voltage (standard voltage)1) Perm. duty cycle under air cooled conditions (LK)
1)

RM RM

Die Magnete sind auf Anfrage bis 60 V DC lieferbar

Other voltages are available on request up to 60 V DC

Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

ca. 117 g ca. 24 g 24 V DC 10 cm B (Tgrenz = 130 C)

Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

appr. 117 g appr. 24 g 24 V DC 10 cm B (max. permissible temperature = 130 C)

Isolationsgruppe nach: VDE 0110 B 150 Prfspannung: 800 V (eff) Wartunsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Waagerechte Kennlinie auf Anfrage. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
M3 M3 M10

Insulation group according to: VDE 0110 B 150 Test voltage: 800 V (eff) Service-free DU armature bearing for maximum durability. Linear force vs. stroke output optional. Return spring optional.

Mae im bestromten Zustand > Hubrichtung Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20

SW17

8 7,5 30 72 % W 100 5,5 40 12,2

2 10

8 13

17 19 26 15 35,3 5 84
2)

Dimensions given with armature in fully home position > Direction of stroke % W Perm. duty cycle (ED)2) Nominal coil power P 20

25 18,9

2) Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)

If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

100 50 F [N]

%ED

20

Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 3 2 1

5 15 25 40

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal 100 position, at 90 % rated voltage and with winding at operating temperature 0 1 2 3 S [mm] 4 stroke s = 0 corresponds to armature in fully home position

Magnet Hauptkatalog

108

Main catalogue

Hochleistungs-Hubmagnet RM 32
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Steckhlsenanschlu A 2,8 DIN 46247 Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)

Heavy Duty Linear Solenoid RM 32


Thrust and pull type
32 32 F M 24 100 % ED F 24 V DC 100 % ED Order specifications Linear solenoid Design type Coil terminals Flying leads (10 cm standard length) Terminal box 2.8 DIN 46247 Nominal voltage (standard voltage)1) Perm. duty cycle under air cooled conditions (LK)
1)

RM RM

Die Magnete sind auf Anfrage bis 60 V DC lieferbar

Other voltages are available on request up to 60 V DC

Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

ca. 235 g ca. 40 g 24 V DC 10 cm B (Tgrenz = 130 C)

DC 24V

F 32- ED RM 100%

Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

appr. 235 g appr. 40 g 24 V DC 10 cm B (max. permissible temperature = 130 C)

Isolationsgruppe nach: VDE 0110 B 150 Prfspannung: 800 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Waagerechte Kennlinie auf Anfrage. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
M4 18

Insulation group according to: VDE 0110 B 150 Test voltage: 800 V (eff) Service-free DU armature bearing for maximum durability. Linear force vs. stroke output optional. Return spring optional.
M4 M3

Mae im bestromten Zustand 10 > Hubrichtung Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20 Anzugszeit (ED)
2)

4 11 45 94 100 65 29 70 10

2 24

10

18 24 32 15 48 5 122 11
2)

Dimensions given with armature in fully home position > Direction of stroke % W ms Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)

% W ms

45 16

25 24

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) %ED

If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

100 50 F [N]

20

Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand

5 10 15 25 50 100

Force vs. Stroke diagramm F = f (s)

2 1

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position

6 S [mm]

Magnet Hauptkatalog

109

Main catalogue

Hochleistungs-Hubmagnet RM 40
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Steckhlsenanschlu (6,3 DIN 46247) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)

Heavy Duty Linear Solenoid RM 40


Thrust and pull type
40 40 F N 24 100 % ED F 24 V DC 100 % ED Order specifications Linear solenoid series Design type Coil terminals Flying leads (10 cm standard length) Terminal box (6.3 DIN 46247) Nominal voltage (standard voltage)1) Perm. duty cycle under air cooled conditions (LK)
1)

RM RM

Die Magnete sind auf Anfrage bis 230 V DC lieferbar

Other voltages are available on request up to 230 V DC

Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

ca. 380 g ca. 60 g 24 V DC 10 cm B (Tgrenz = 130 C)

0 C1 VD 24

-F D E 40 RM 0 %

Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

appr. 380 g appr. 60 g 24 V DC 10 cm B (max. permissible temperature = 130 C)

Isolationsgruppe nach: VDE 0110 C 300 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Waagerechte Kennlinie auf Anfrage. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.

Insulation group according to: VDE 0110 C 300 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Linear force vs. stroke output optional. Return spring optional.

Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20 Anzugszeit (ED)


2)

% W ms

100 11 36

75 13,5

45 21

25 34

15 54

5 165 11
2)

% W ms

Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) %ED

If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

100 50 F [N]

5 15 25 45 75 100

20

Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand

Force vs. Stroke diagramm F = f (s)

2 1

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature 0 2 4 6 S [mm] 8 stroke s = 0 corresponds to armature in fully home position

Magnet Hauptkatalog

110

Main catalogue

Hochleistungs-Hubmagnet RM 40
Stoende und ziehende Ausfhrung

Heavy Duty Linear Solenoid RM 40


Thrust and pull type

22

M5

M5

12 16

5 45 110

2 32

12

20 22 30 40

Mae im bestromten Zustand > Hubrichtung

Dimensions given with armature in fully home position > Direction of stroke

Magnet Hauptkatalog

111

Main catalogue

M4

Magnet Hauptkatalog

112

Main catalogue

Hochleistungs-Hubmagnete RM 050 ... RM 100

Heavy Duty Linear Solenoids RM 050 ... RM 100

Bestellformel Hubmagnet Bauart

RM 070 W O R O R N RM 050 060 070 080 090 100

24 V DC 100 % ED Order specifications Linear solenoid series Design type

mm

mm

bis 160 mm auf Anfrage Waagerechte Kraft-Weg-Kennlinie Ausfhrung2) Hubbegrenzung Stel Flansch ohne mit rechts3) beidseitig ohne rechts3) links4) Faltenbalg ohne rechts3) links4) beidseitig5) Anschluart Litze (Standardlnge 20 cm) Gertestecker6) Nennspannung 24 V DC 205 V DC (an 230 V AC nach SI-Gleichrichterbrcke)

1601) W O H R B O R L O R L B F N 24 205

160 mm optional Horizontal frontal force vs. stroke output Description2) Stroke limit Plunger Flange without with right hand side3) both sides without right hand side3) left hand side4) Gaiter without right hand side3) left hand side4) both sides5) Coil terminals Flying leads (20 cm standard length) plug-in socket connection6) Operating voltage 24 V DC 205 V DC (connected to 230 V AC with SI- bridge rectifier)

Zulssige relative Einschaltdauer bei Luftkhlung (LK) Bis 160 mm auf Anfrage 2) Siehe unten 3) Entgegengesetzt zur elektr. Anschluseite 4) An der elektr. Anschluseite 5) Nur mit Hubbegrenzung lieferbar 6) Fr Steckhlse 6,3 DIN 46247 und Gertesteckdose Z 801 und Z 811 Zubehr siehe Seite 130-131 ca.12
1)

100 % ED Perm. duty cycle under air cooled conditions (LK) Up to 160 mm optional See below 3) Opposite to electrical connection 4) Same side as electrical connection 5) Available only with stroke limit 6) For plug-in socket 6.3 DIN 46247 and plug Z 801 and Z 811 Accessories see pages 130-131
2) 1)

200 +15

ca.12

Anschluarten

Coil terminals

Beispiele fr Ausfhrungen: Ohne Anschlagdeckel; keine Hubbegrenzung im offenen Zustand

Examples of design types: without end stop without stoke limit in the open position

OBOO

OBLO

OBOR

ORRO

OROR

HBOO

HBLO

HBOL

HRRO

HROR

Magnet Hauptkatalog

113

Main catalogue

Hochleistungs-Hubmagnet RM 050

Heavy Duty Linear Solenoid RM 050

Hochleistungs-Hubmagnet RM 050 Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

Heavy duty linear solenoid RM 050 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

ca. 610 g ca. 200 g 24 V DC 20 cm F (Tgrenz = 155 C)

appr. 610 g appr. 200 g 24 V DC 20 cm F (max. permissible temperature = 155 C)

Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 10 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.

Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 10 mm. Return spring optional.

Zul. rel. Einschaltdauer (ED)1) Nennaufnahme P 20 Anzugszeit (ED)


1)

% W ms

100 20 40

60 30

35 55

25 70

15 115

5 300 15
1)

% W ms

Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED

If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

200

Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 5

Force vs. Stroke diagramm F = f (s)

20 10 0

15 W = horizontal characteristic 25 35 Force measured when operating in horizontal 60 position, at 90 % rated voltage and winding at operating temperature 100 2 4 6 8 S [mm] 10 stroke s = 0 corresponds to armature in fully home position

Magnet Hauptkatalog

114

Main catalogue

Hochleistungs-Hubmagnet RM 050

Heavy Duty Linear Solenoid RM 050

ohne Anschlagdeckel

without end stop

M5 32 16

34

5 5

50

50

17

135

57

Direction of stroke

41

Hubrichtung

16

M5 M4 4,8 19 30 30

50 40 30

36

mit Anschlagdeckel

with end stop

M5 32 16

34

50 42

Direction of stroke

65

Hubrichtung

10

32

28 16

65

72

30 M4

50 40 30

19 30

4,8

M5

34

Magnet Hauptkatalog

115

50 42

Main catalogue

Hochleistungs-Hubmagnet RM 060

Heavy Duty Linear Solenoid RM 060

Hochleistungs-Hubmagnet RM 060 Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

Heavy duty linear solenoid RM 060 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

ca. 1300 g ca. 250 g 24 V DC 20 cm F (Tgrenz = 155 C)

appr. 1300 g appr. 250 g 24 V DC 20 cm F (max. permissible temperature = 155 C)

Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 12 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.

Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 12 mm. Return spring optional.

Zul. rel. Einschaltdauer (ED)1) Nennaufnahme P 20 Anzugszeit (ED)


1)

% W ms

100 25 45

40 60

25 98

15 150

5 381 17
1)

% W ms

Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED

If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

200

Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 F [N] Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand

5 15 25 40 100

Force vs. Stroke diagramm F = f (s)


W = horizontal characteristic

20 10 0

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature stroke s = 0 corresponds to armature in fully home position

10

12 S [mm]

15

Magnet Hauptkatalog

116

Main catalogue

Hochleistungs-Hubmagnet RM 060

Heavy Duty Linear Solenoid RM 060

ohne Anschlagdeckel

without end stop

M6 M6 41 18 36

5 7

152

65

17

64

72

Direction of stroke

Hubrichtung

37 18

M6 35 5,8 M5

34 29

36

60 45 35

19 30

mit Anschlagdeckel

with end stop

67 54

M6 M6 41 18 36

Direction of stroke

Hubrichtung

82

10

34

29 18

81

89

M6 5,8 M5 35

36

60 45 35

19 30

Magnet Hauptkatalog

117

67 54

Main catalogue

Hochleistungs-Hubmagnet RM 070

Heavy Duty Linear Solenoid RM 070

Hochleistungs-Hubmagnet RM 070 Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

Heavy duty linear solenoid RM 070 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

ca. 2000 g ca. 400 g 24 V DC 10 cm F (Tgrenz = 155 C)

appr. 2000 g appr. 400 g 24 V DC 10 cm F (max. permissible temperature = 155 C)

Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 15 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.

Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 15 mm. Return spring optional.

Zul. rel. Einschaltdauer (ED)1) Nennaufnahme P 20 Anzugszeit (ED)


1)

% W ms

100 31 54

40 78

25 121

15 198

5 472 25
1)

% W ms

Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED

If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

200

Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N]

5 15

Force vs. Stroke diagramm F = f (s)

25 W = horizontal characteristic 40 Force measured when operating in horizontal position, at 90 % rated voltage and winding at 100 operating temperature 5 10 15 S [mm] 20 stroke s = 0 corresponds to armature in fully home position

20 10 0

Magnet Hauptkatalog

118

Main catalogue

Hochleistungs-Hubmagnet RM 070

Heavy Duty Linear Solenoid RM 070

ohne Anschlagdeckel

without end stop

M8 49 20

43

5 8

177

75

20

43 20

39 10 34

74

84

Direction of stroke

Hubrichtung

M8 38 M5 7

43

70 52 38

19 30

mit Anschlagdeckel

with end stop

M8 49 20

43

80 62

Direction of stroke

Hubrichtung

10

39

34 20

10

103

94

93

M8 38 M5 7

43

70 52 38

19 30

Magnet Hauptkatalog

119

80 62

Main catalogue

Hochleistungs-Hubmagnet RM 080

Heavy Duty Linear Solenoid RM 080

Hochleistungs-Hubmagnet RM 080 Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

Heavy duty linear solenoid RM 080 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

ca. 2900 g ca. 500 g 24 V DC 20 cm F (Tgrenz = 155 C)

appr. 2900 g appr. 500 g 24 V DC 20 cm F (max. permissible temperature = 155 C)

Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 20 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.

Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 20 mm. Return spring optional.

Zul. rel. Einschaltdauer ED)1) Nennaufnahme P 20 Anzugszeit (ED)


1)

% W ms

100 37 75

45 94

25 149

15 226

5 685 34
1)

% W ms

Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED

If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

200

Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 15 25 45 100

Force vs. Stroke diagramm F = f (s)


W = horizontal characteristic

20 10 0

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature 5 10 15 20 S [mm] 25 stroke s = 0 corresponds to armature in fully home position

Magnet Hauptkatalog

120

Main catalogue

Hochleistungs-Hubmagnet RM 080

Heavy Duty Linear Solenoid RM 080

ohne Anschlagdeckel

without end stop

M10 30

50

5 9,5

65

85

84

216 45

23

9,5

50

12

96

Direction of stroke

M10

30

Hubrichtung

45

M10

50

80

62

45

M5

19 30

9,5

90 50

mit Anschlagdeckel

M10 30

65

72

with end stop

Direction of stroke

9,5

Hubrichtung

110

109

241 45 30

25

48

10

M10 9,5 45

50

12

121

M10

50

80

62

45

M5

19 30

90

Magnet Hauptkatalog

121

72

Main catalogue

Hochleistungs-Hubmagnet RM 090

Heavy Duty Linear Solenoid RM 090

Hochleistungs-Hubmagnet RM 090 Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

Heavy duty linear solenoid RM 090 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

ca. 4500 g ca. 800 g 24 V DC 20 cm F (Tgrenz = 155 C)

appr. 4500 g appr. 800 g 24 V DC 20 cm F (max. permissible temperature = 155 C)

Isolationsgruppe nach: VDE 0110 C 600 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 25 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.

Insulation group according to: VDE 0110 C 600 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 25 mm. Return spring optional.

Zul. rel. Einschaltdauer( ED)1) Nennaufnahme P 20 Anzugszeit (ED)


1)

% W ms

100 51 85

40 102

25 194

15 303

5 748 38
1)

% W ms

Perm. duty Cycle (ED)1) Nominal coil power P 20 Actution time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 2000 1000 700 500 %ED

If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

Kraft-Weg-Diagramm F = f (s)
W = Waagerechte Kennlinie

200 100 50 20 10

5 15 25

Force vs. Stroke diagramm F = f (s)

40 W = horizontal characteristic 100 Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature 5 10 15 20 25 S [mm] 30 stroke s = 0 corresponds to armature in fully home position

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand

F [N]

Magnet Hauptkatalog

122

Main catalogue

Hochleistungs-Hubmagnet RM 090

Heavy Duty Linear Solenoid RM 090

ohne Anschlagdeckel

without end stop

M12 40

55

5 11

80

251

11

23

12

106

95

94

Direction of stroke

66

40

60 M12 52

Hubrichtung

55

55 9,5

M6

90

68

52

100 55

19 30

mit Anschlagdeckel

M12 40

80

80

with end stop

Direction of stroke

Hubrichtung

125

11

55

40

12

53

M12 52 9,5 55

M6

12

124

90

68

52

100

19 30

Magnet Hauptkatalog

123

80

136

Main catalogue

Hochleistungs-Hubmagnet RM 100

Heavy Duty Linear Solenoid RM 100

Hochleistungs-Hubmagnet RM 100 Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

Heavy duty linear solenoid RM 100 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

ca. 6400 g ca. 1100 g 24 V DC 20 cm F (Tgrenz = 155 C)

appr. 6400 g appr. 1100 g 24 V DC 20 cm F (max. permissible temperature = 155 C)

Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 30 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.

Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 30 mm. Return spring optional.

Zul. rel. Einschaltdauer (ED)1) Nennaufnahme P 20 Anzugszeit (ED)


1)

% W ms

100 69 110

40 162

25 255

15 400

5 1071 45
1)

% W ms

Perm. duty Cycle (ED)1) Nominal coil power P 20 Actution time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 2000 1000 700 500 5 %ED

If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

Kraft-Weg-Diagramm F = f (s)
W = Waagerechte Kennlinie

200 100 50

15 25 40 100

Force vs. Stroke diagramm F = f (s)


W = horizontal characteristic

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand

F [N]

20 10 0 10 20 30 S [mm] 40

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature stroke s = 0 corresponds to armature in fully home position

Magnet Hauptkatalog

124

Main catalogue

Hochleistungs-Hubmagnet RM 100

Heavy Duty Linear Solenoid RM 100

ohne Anschlagdeckel

without end stop

M12 50

60

6 12

95

110

109

294

12

24

13

122

Direction of stroke

77

71 M12 58

Hubrichtung

50

65

M12 11,5

60

100

M8

76

58

110 60

19 30

mit Anschlagdeckel

M12 50

95

88

with end stop

Direction of stroke

Hubrichtung

12

143

144

65 6

14

58

50

M12 11,5 58 60

100

M8

13

76

58

110

19 30

Magnet Hauptkatalog

125

88

156

Main catalogue

Hochleistungs-Umkehr-Hubmagnet URM 20

Heavy Duty Two-Directional Linear Solenoid URM 20

Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)

URM URM

20 20

24 V DC

100 % ED

Order specifications Linear solenoid Design type Coil terminals

F 24 100 % ED

Flying leads (10 cm standard length) Nominal voltage (standard voltage)1) Perm. duty cycle under air cooled conditions (LK)
1)

Die Magnete sind auf Anfrage bis 60 V DC lieferbar

Other voltages are available on request up to 60 V DC

Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

ca. 105 g ca. 19 g 24 V DC 10 cm B (Tgrenz = 130 C)

Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

appr. 105 g appr. 19 g 24 V DC 10 cm B (max. permissible temperature = 130 C)

Isolationsgruppe nach: VDE 0110 C 75 Prfspannung: 800 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer.

Insulation group according to: VDE 0110 C 75 Test voltage: 800 V (eff) Long life expectancy through plastic bobbin armature bearing.

Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20 Anzugszeit (ED)


2)

% W ms

100 3,9 11

45 8

25 13,5

15 21

5 59 5
2)

% W ms

Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)

Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)

If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

100 50 F [N]

%ED

20

Force vs. Stroke diagramm F = f (s)


10 5 15 25 45 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature 100 0 1 2 S [mm] 3 stroke s = 0 corresponds to armature in fully home position

Kraft-Weg-Diagramm F = f (s)
5

2 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung 1

Magnet Hauptkatalog

126

Main catalogue

Hochleistungs-Umkehr-Hubmagnet URM 20

Heavy Duty Two-Directional Linear Solenoid URM 20

21

21

M3

M3

1 9 20 2 55 0,2
+0,6

16 20

96 0,5

Mae gelten, wenn System 1 bestromt <> Hubrichtung

Dimensions given when system 1 current-carrying <> Direction of stroke

Magnet Hauptkatalog

127

SW14

M8

Main catalogue

Hochleistungs-Umkehr-Hubmagnet URM 50

Heavy Duty Two-Directional Linear Solenoid URM 50

Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Gertestecker1) Nennspannung (Standardspannung)2) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1) 2)

URM URM

50 50

24 V DC

100 % ED

Order specifications Linear solenoid Design type Coil terminals

F N 24 100 % ED

Flying leads (10 cm standard length) Plug-in socket connection1) Nominal voltage (standard voltage)2) Perm. duty cycle under air cooled conditions (LK)
1) 2)

Fr Steckhlsen 6,3 DIN 46247 Die Magnete sind auf Anfrage bis 230 V DC lieferbar

For socket 6.3 DIN 46247 Other voltages are available on request up to 230 V DC

Gewicht: Magnet: Anker: Standard: Spannung: Litze: Isolierstoffklasse:

ca. 1200 g ca. 180 g 24 V DC 10 cm B (Tgrenz = 130 C)

Isolationsgruppe nach: VDE 0110 C 75 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer.

= 24V

0-N D M5 % E R U 100

Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:

appr. 1200 g appr. 180 g 24 V DC 10 cm B (max. permissible temperature = 130 C)

Insulation group according to: VDE 0110 C 75 Test voltage: 2500 V (eff) Long life expectancy through plastic bobbin armature bearing.

Zul. rel. Einschaltdauer (ED)3) Nennaufnahme P 20

% W

100 15

70 24

40 38

25 56

15 89

5 280

% W

Perm. duty cycle (ED)3) Nominal coil power P 20

3) Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)

3) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

1000 500

%ED

200

Kraft-Weg-Diagramm F = f (s)
100 50 F [N] Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand

5 15 25 40

Force vs. Stroke diagramm F = f (s)

20 10 0

Force measured when operating in horizontal 70 position, at 90 % rated voltage and with winding at 100 operating temperature 2 4 6 S [mm] 8 stroke s = 0 corresponds to armature in fully home position

Magnet Hauptkatalog

128

Main catalogue

Hochleistungs-Umkehr-Hubmagnet URM 50

Heavy Duty Two-Directional Linear Solenoid URM 50

ca.52

30 19

M5

M5

30

104 156

40 50

Mae gelten, wenn System 1 bestromt <> Hubrichtung

Dimensions given when system 1 current-carrying <> Direction of stroke

Magnet Hauptkatalog

129

M4

ca.72 ca.60

15

15

Main catalogue

Hochleistungs-Hubmagnete Zubehr Typ RM

Heavy Duty Linear Solenoids Accessories for Series RM

Gertesteckdose Z 801 Kabelverschraubung SPG 9 fr Kabeldurchmesser 6-8 mm Gertesteckdose Z 811 Gertesteckdose mit eingebautem Si-Brckengleichrichter Typ GDML 211-GB 1 Zu beziehen bei: Firma Richard Hirschmann Postfach 110 73728 Esslingen

53 PG9 16

Plug-in socket for the appliance Screw joint PG 9 for lead diameter 6-8 mm Plug-in socket Z 811 Plug-in socket with built-in Si-bridge rectifier Type GDML 211-GB 1 Obtainable from: Firma Richard Hirschmann PO Box 110 73728 Esslingen
22,5

27,5

Flansch (Befestigungsschrauben werden mitgeliefert)


J

3,5

M3

35

Flange (Mounting screws are part of the shipment)


D B C

L K A

Bestellbezeichnung
BestellNr. Z 839 Z 840 Z 841 Z 842 Z 843 Z 844 Typ RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 Mae (mm) A 50,0 70,0 80,0 90,0 100,0 110,0 B 7,0 8,0 10,0 12,0 12,0 13,0 C 12,0 13,0 15,0 17,0 17,0 19,0 D 30,0 35,0 38,0 45,0 52,0 58,0 E 23,0 29,0 32,5 38,0 43,0 49,0 F 30,0 35,0 38,0 45,0 52,0 58,0 G 60,5 70,5 80,5 90,5 100,5 H 1,0 1,0 1,0 1,0 1,0 I 4,8 5,8 7,0 9,5 9,5 11,5 J 4,3 5,3 5,3 6,4 6,4 8,4 Dimensions (mm) K 42,0 54,0 62,0 72,0 80,0 88,0 L 40,0 45,0 52,0 62,0 68,0 76,0

G F E H

Order specification
Order Type RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 number Z 839 Z 840 Z 841 Z 842 Z 843 Z 844

Magnet Hauptkatalog

130

Main catalogue

Hochleistungs-Hubmagnete Zubehr Typ RM

Heavy Duty Linear Solenoids Accessories for Series RM

Anschlagdeckel (Befestigungsschrauben werden mitgeliefert)

H J G

End stop (Mounting screws are part of the shipment)

I B A

K D C

Bestellbezeichnung
BestellNr. Z 838 Z 845 Z 846 Z 847 Z 848 Z 849 Typ RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 Mae (mm) A 50,0 60,0 70,0 80,0 90,0 100,0 B 40,0 45,0 52,0 62,0 68,0 76,0 C 20,0 22,0 24,0 30,0 35,0 40,0 D 15,0 17,0 19,0 25,0 30,0 34,0 E 23,0 29,0 33,0 38,0 43,0 48,0 F 30,0 35,0 38,0 45,0 52,0 58,0 G 5,5 5,5 5,5 5,5 5,5 6,5 H 11,0 12,0 15,0 20,0 25,0 30,0 I M4 M5 M5 M5 M6 M8

E F

Order specification
Dimensions (mm) J 4,3 5,3 5,3 5,3 6,4 8,4 K 10,0 10,0 10,0 10,0 12,0 14,0 Type RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 Order number Z 838 Z 845 Z 846 Z 847 Z 848 Z 849

Gabelkopf

Fork

BestellNr. Ordernumber
1)

A 12 23 27 32 40

B 15 29 34 42 52

C 9 16 19 26 32

F 6 10 12 16 20

An2) schlu Connection G M3 M5 M6 M8 M10


2) 1)

2)

Gabelkpfe, verzinkt und gelb chromatiert, werden ohne Mutter geliefert. Sicherung z. B. durch Loctite o.. Weitere Ausfhrungen (> M10) auf Anfrage

38.304 37.304 36.304 35.3041) 34.3042)

2,5 3,1 5 6 8 10 5 6 8 10

Forks are galvanised and chromed yellow. Supplied without a nut. Secure using e.g. Loctite or a simular product. Further specifications (> M10) optional

Faltenbalge siehe Zubehr-bersicht, Seite 9

Gaiters see accessories page 9

Magnet Hauptkatalog

131

Main catalogue

Magnet Hauptkatalog

132

Main catalogue

You might also like