2012-2013
C-SAS-2012
At Your Service
NEW PRODUCTS
GCN-MEP
The new GCN-MEP gas-actuated concrete nailer is the ideal solution for attaching light-duty xtures to concrete, CMU and metal deck for mechanical, electrical and plumbing (MEP) attachments. Since the tool does not require electrical cords or pneumatic hoses, the gasactuated GCN-MEP is extremely portable, which helps to increase productivity. For more information about this product, go to page 179.
Strong-Bolt 2
This innovative, new wedge anchor features a re-designed, tri-segmented clip made of special, high-strength alloy that enables it to outperform many other cracked-concrete wedge anchors, including the original Strong-Bolt. Strong-Bolt 2 has also received classication as a Category 1 anchor, which is the highest reliability rating as outlined by the ICC-ES AC193 acceptance criteria. It has been tested and code listed under the 2009 IBC requirements for installation in the most adverse conditions, including performance in cracked concrete under static and seismic loading. For more information about this product, go to page 96. ICC-ES ESR-3037
NEW PRODUCTS
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Table of Contents
Adhesives
AT Acrylic Adhesive . . . . . . . . . . . . 5366 Acrylic Usage Estimation Guides . . . 6769
NEW
Gas-Actuated Fastening
Other
Allowable Stress Design Method . . . . . 226 Alphabetical Index of Products . . . . . . . 17 Anchor Selection Guide . . . . . . . . . . . . . . 8 Corrosion Information . . . . . . . . . . . . . . 11 Example Design Calculations . . . . 231237 General Installations for the Installer . . . 13 General Instruction for the Designer . . . 14 Glossary of Common Terms . . . . . . . . 238 Limited Warranty . . . . . . . . . . . . . . . . . . 10 Supplemental Topics for Anchors . . . . 224 Table Icons . . . . . . . . . . . . . . . . . . . . . . . 13 Technical Support . . . . . . . . . . . . . . . . . 11 Treatment of Design Methods . . . . . . . 229 Strength Design Method . . . . . . . . . . . 226
GCN-MEP Gas-Actuated Concrete Nailer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 GCN150 Gas-Actuated Concrete Nailer . . . NEW A dhesive Accessories . . . . . . . . . . . 7277 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Adhesive Anchoring W Installation Instructions . . . . . . . . . . 7071 NE Gas-Actuated Fasteners and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 183186 Adhesive Troubleshooting Guide . . . . . . 78 Powder-Actuated Fastening Crack-Pac Injection Adhesive . . . . 8689 Application Matrix - Tools/Trades 188189 Crack-Pac Flex H2O Injection Adhesive . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9093 NEW E xtension Pole Tools/Accessories . . . . 187 Fastener Tension and Shear Loads Crack Repair Accessories . . . . . . . . . . . 94 . . . . . . . . . . . . . . . . . . . . . . . . . . . 208214 EDOT Adhesive . . . . . . . . . . . . . . . . . . . 47 Powder-Actuated Tools Epoxy Crack Injection Guide . . . . . . 8889 NEW P TP-27L . . . . . . . . . . . . . . . . . . . . . . 192 Epoxy Usage Estimation Guides . . . 4851 NEW P TP-27LMAGR . . . . . . . . . . . . . . . . . 192 ETI-SLV, -LV and -GV Injection Adhesives . . . . . . . . . . . . . . . . . . . . . . . . . 85, 8889 NEW P TP-27S . . . . . . . . . . . . . . . . . . . . . . 193 ET-HP Adhesive (formerly ET) . . . 3746 NEW P TP-27SMAGR . . . . . . . . . . . . . . . . . 193 Retrot Bolt . . . . . . . . . . . . . . . . . . . . . . 77 PT-27 . . . . . . . . . . . . . . . . . . . . . . . . 195
SET Adhesive . . . . . . . . . . . . . . . . . . 2236 PT-22 . . . . . . . . . . . . . . . . . . . . . . . . 196 SET-XP Adhesive . . . . . . . . . . . . . . 1621 PT-22GS . . . . . . . . . . . . . . . . . . . . . . 197 VGC Vinylester Glass Capsule . . . . . 7983 PT-22H . . . . . . . . . . . . . . . . . . . . . . . 198 PT-22P . . . . . . . . . . . . . . . . . . . . . . . 199
Special Section
Connectors for Cold-Formed Curtain-Wall Construction . . . . . . 240251
Mechanical Anchors
Blue Banger Hanger Threaded Insert . . 157 Crimp Anchor . . . . . . . . . . . . . . . . . . . . 168 Drop-In Anchor . . . . . . . . . . . . . . . . . . 150
NEW
Powder-Actuated Fasteners . . . . . 201214 Powder Loads . . . . . . . . . . . . . . . . . . . 200 Repair Kits . . . . . . . . . . . . . . . . . . . . . . 207 Safety Principles . . . . . . . . . . . . . . . . . 187 Tool/Load/Fastener Matrix . . . . . . 190191
A Taper Drill Bits . . . . . . . . . . . . . . . . . 219 Bushing Tools . . . . . . . . . . . . . . . . . . . . 222 Core Bits . . . . . . . . . . . . . . . . . . . . . . . . 222 Demolition Chisels and Bits . . . . . . . . . 221 Drill Bit Tool Selection Guide . . . . . . . . 216 Ground Rod Drivers . . . . . . . . . . . . . . . 220 Plate Cutters . . . . . . . . . . . . . . . . . . . . . 220 Rebar Cutters . . . . . . . . . . . . . . . . . . . . 220
Lag Screw Expansion Shield . . . . . . . . 172 Machine Screw Anchor . . . . . . . . . . . . 173 Nailon Pin Drive Anchor . . . . . . . . . . . . 171
Plastic Screw Anchor . . . . . . . . . . . . . . 175 Sleeve-All Anchor . . . . . . . . . . . . . . . . 146 Split Drive Anchor . . . . . . . . . . . . . . . . 170 Spring Wing Toggle Bolt . . . . . . . . . . . 177
Strong-Bolt Wedge Anchor . . . . . . . . 106 Scalers . . . . . . . . . . . . . . . . . . . . . . . . . 220 SDS-Max Drill Bits . . . . . . . . . . . . . . . . 218 NEW S trong-Bolt 2 Wedge Anchor . . . . . . . . 96 Sure Wall Drywall Anchor/Toggle . . . . 176 Tie-Wire Wedge-All Anchor . . . . . . . . 133
SDS-Plus Drill Bits . . . . . . . . . . . . 217218 Shank Adaptors . . . . . . . . . . . . . . . . . . 220 Spline Shank Drill Bits . . . . . . . . . 218219 Straight Shank Drill Bits . . . . . . . . . . . . 219 Warranty Claims . . . . . . . . . . . . . . . . . 223
Titen Screw . . . . . . . . . . . . . . . . . . . . 162 Titen Stainless-Steel Screw . . . . . . . . 164 Titen HD Anchor . . . . . . . . . . . . . . . . . 110
NEW
Titen HD Mini Anchor . . . . . . . . . . . . . 122 Titen HD Rod Coupler . . . . . . . . . . . . 127 Titen HD Rod Hanger . . . . . . . . . . . . . 123
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
AD Drill Bit Shank Adaptor . . . . . . . . . . . . . 220 GFC Gas Fuel Cell . . . . . . . . . . . . . . . . . . . . 185 PHK 6MM Headed Pin . . . . . . . . . . . . . . . . 205 GMR Magnetic Ring . . . . . . . . . . . . . . . . . . 185 PHN 8MM Headed Pin . . . . . . . . . . . . . . . . 204 GRH, GTH, GTS, GW Gas Pins . . . . . . . . . 180 PHNT 8MM Headed Tophat Fastener . . . . . . .205 GWL Lathing Washer . . . . . . . . . . . . . . . . . 185 PHNW 8MM Headed Pin with 1" Washer . . 205 A DTA Pneumatic Dispensing Tools . . . . . . . 73
ARC Adhesive Retaining Caps . . . . . . . . . . . 74 HELI Helical Wall Tie . . . . . . . . . . . . . . . . . 166 PHSNA Collated Fasteners Metric . . . . . . 206 AST Adhesive Shear Tube . . . . . . . . . . . . . . 77 HWA Hollow Wall Anchor . . . . . . . . . . . . . 174 PHV3 3 8" Headed Pin . . . . . . . . . . . . . . . . . 203 AT Acrylic Adhesive . . . . . . . . . . . . . . . . . . 53 LSES Lag Screw Expansion Shield . . . . . . 172 PINW 100 through 300 .300" Headed Pin with 1716" Washer . . . . . . . . . . . . . . . . . . . . . 202 ATS & ATSP Acrylic Screens . . . . . . . . . 7576 MC Rebar Cutter Shank Straight . . . . . . 220 BBMD Blue Banger Hanger . . . . . . . . . . . 157 MCP Plate Cutter Head . . . . . . . . . . . . . . . 220 PINWP 100 through 300 .300" Headed Pin with 1716" Plastic Washer . . . . . . . . . . . . . . . 203 BBRD Blue Banger Hanger . . . . . . . . . . . . 157 MCR Rebar Cutter Head . . . . . . . . . . . . . . . 220 PKP Concrete Forming Pin . . . . . . . . . . . . 206 BBWF Blue Banger Hanger . . . . . . . . . . . 157 MCS Rebar Cutter Shank Spline . . . . . . . 220 PSATG Plastic Screw Anchor . . . . . . . . . . 175 CBMX One Piece Core Bit SDS-MAX Shank MCSDM Rebar Cutter Shank SDS-MAX . . 220 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 MCSDP Rebar Cutter Shank SDS-PLUS . . 220 PSLV3 8" Threaded Stud . . . . . . . . . . . . . 204 1 PSLV4 4" Threaded Stud . . . . . . . . . . . . . 204 CBSP One Piece Core Bit Spline Shank . . . . 222 MDA 'A' Taper Shank Drill Bits . . . . . . . . . . 219 PSP Piloted Setting Punch . . . . . . . . . . . . 172 CD Crimp Anchor . . . . . . . . . . . . . . . . . . . . 168 MDB Straight Shank Drill Bits . . . . . . 165, 219 PT-22 .22 Cal. Powder-Actuated Tool . . . . . 196 CDBE One Piece Core Bit Ejector Key . . 222 MDMX SDS-MAX & SDS-MAX Quad NEW CDT10S Premium Adhesive Dispensing Tool . 72 Head Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 PT-22GS .22 Cal. Grip Shot Powder-Actuated Tool . . . . . . . . . . . . . . . . . . 197 MDPL SDS-PLUS Shank Bits . . . . . . 217218 CHH Hex Shank Chisels & Demolition Bits PT-22H Hammer Activated Powder Tool . . 198 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 MDSP Spline Shank Drill Bits . . . . . . 218219 PT-22P Powder-Actuated Tool . . . . . . . . . . 199 CHMX SDS-MAX Chisels & Demolition Bits MSD Mushroom Head Split Drive . . . . . . . 170 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 PT-27 .27 Cal. Powder-Actuated Tool . . . . 195 N Nailon (nylon) . . . . . . . . . . . . . . . . . . . . . 171 CHPL SDS-PLUS Chisels & Demolition Bits PT-27HD Heavy-Duty Powder-Actuated Tool P22 .22 Cal. Powder Load Single, Crimped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 W CHSP Spline Shank Chisels & Demolition Bits P TP-27L .27 Cal. Auto Powder-Actuated Tool NE P22LRSC .22 Cal. Powder Load Single, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Straight Wall . . . . . . . . . . . . . . . . . . . . . . . . . 200 CIP Crack Injection Paste Over . . . . . . . . . . 94 EW P TP-27LMAGR .27 Cal. Auto Powder P25SL .25 Cal. Powder Load Strip . . . . . . 200 N Actuated Tool w/ Magazine . . . . . . . . . . . . . . 192 CIP-F Crack Injection Paste Over . . . . . . . . 94 P27LVL .27 Cal. Powder Load Single, Long NEW P TP-27S .27 Cal. Auto Powder-Actuated Tool CPFH09 Crack-Pac Flex-H2O Crack Sealer . . 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 CSD Countersunk Split Drive . . . . . . . . . . . 170 P27SL .27 Cal. Powder Load Strip . . . . . . . 200 W P TP-27SMAGR .27 Cal. Auto PowderE CTRB One Piece Core Bit Center Pilot Bit . . 222 PBXDP BX Cable Strap . . . . . . . . . . . . . . . 203 N Actuated Tool w/ Rotating Magazine . . . . . . 193 DIA Drop-In Anchor . . . . . . . . . . . . . . . . 150 PCC Conduit Clip . . . . . . . . . . . . . . . . . . . . 203 PTRH Threaded Rod Hanger . . . . . . . . . . . 206 DIAST Drop-In Anchor Setting Tool . . . . . 151 PCLDP Ceiling Clip . . . . . . . . . . . . . . . . . . . 203 RFB Retrot Bolt . . . . . . . . . . . . . . . . . . . . . 77 DMSA Double Machine Screw Anchor . . . . 173 PDP .300" Headed Pin . . . . . . . . . . . . . . . . 201 SET Epoxy Adhesive . . . . . . . . . . . . . . . . . . 22 DSD Duplex Head Split Drive . . . . . . . . . . . 170 NEW P DPA .300" Headed Fastener SET-XP Epoxy Adhesive . . . . . . . . . . . . . . 16 EDOT General-Purpose Anchoring Adhesive with .157" Shank Diameter . . . . . . . . . . . . . . 201 SL Sleeve-All Anchor . . . . . . . . . . . . . . . . 146 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 PDPH .300" Headed Fasteners SMSA Single Machine Screw Anchor . . . . 173 EDT Epoxy Dispensing Tools . . . . . . . . . . . . 72 with .177" Shank Diameter . . . . . . . . . . . . . . 201 STB Strong-Bolt Wedge Anchor . . . . . . . 106 W NE E DTA Pneumatic Dispensing Tools . . . . . . . 72 PDPHMG .300" Headed Fasteners with .177" Shank Diameter Mechanically Galvanized . . 202 NEW S TB2 Strong-Bolt 2 Wedge Anchor . . . . . . 96 EIF Injection Fitting . . . . . . . . . . . . . . . . . . . 94 SWN Sure Wall Anchor (Nylon) . . . . . . . . . 176 EIP Injection Port . . . . . . . . . . . . . . . . . . . . . 94 PDPHWL .300" Headed Fasteners with 1" Metal Washers with .177" Shank Diameter . . 202 SWTB Spring Wing Toggle Bolt . . . . . . . . . 177 EMN Epoxy Mixing Nozzle . . . . . . . . . . . . . . 74 PDPMG .300" Headed Fasteners SWTH Toggle Only . . . . . . . . . . . . . . . . . . . 177 EMNO Opti-Mix Mixing Nozzle . . . . . . . . . 94 Mechanically Galvanized . . . . . . . . . . . . . . . . 202 SWZ Sure Wall Anchor (Zinc) . . . . . . . . . . 176 ESA Expansion Screw Anchor . . . . . . . . . . 172 PDPSS Type 316 Stainless-Steel .300" Headed SWZT Sure Wall Toggle . . . . . . . . . . . . . . . 176 ET-HP (formerly ET) Epoxy Adhesive . . . . 37 Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 TCA Torq-Cut Anchor . . . . . . . . . . . . . . . 129 ETB Hole Cleaning Brush . . . . . . . . . . . . . . . 77 PDPW .300" Headed Pin with 34" Washer . . 202 THD Titen HD Anchor . . . . . . . . . . . . . . . . 110 ETI Crack Injection Epoxy . . . . . . . . . . . . . . 85 PDPWL .300" Headed Pin with 1" Washer . . 202 THD MINI Small Titen HD Anchor . . . . . . 122 ETIPAC Crack-Pac Injection Epoxy . . . . . . . 86 PDPWLMG .300" Headed Fasteners with 1" THD RC Titen HD Rod Coupler . . . . . . . . 127 Metal Washers Mechanically Galvanized . . 202 ETR Epoxy Paste-Over . . . . . . . . . . . . . . . . . 94 THD RH Titen HD Rod Hanger . . . . . . . . . 123 ETS & ETSP Epoxy Screens . . . . . . . . . 7576 PDPWLSS 316 Stainless-Steel .300" Headed Fastener with 1" Washer . . . . . . . . . . . . . . . . 202 TTN Titen Screw . . . . . . . . . . . . . . . . . . . 162 EZAC Pin Drive Anchor . . . . . . . . . . . . . . . 161 TTNSS Titen Stainless-Steel Screw . . . . 164 E-Z-CLICK Injection System . . . . . . . . . . . . 94 PDPT .300" Headed Tophat Pin . . . . . . . . . 203 PECLDP Ceiling Clip . . . . . . . . . . . . . . . . . . 203 TTNT Titen Screw Installation Tool . . . . . 165 NEW GCN Gas-Actuated Concrete Nailers . . 179, 182 PET Extension Pole Tools . . . . . . . . . . . . . 187 TWD Tie-Wire Anchor . . . . . . . . . . . . . . . . 133 GAC, GBR, GCC, GCL, GCT Gas Pins . . . . 180 PHBC Highway Basket Clip . . . . . . . . . . . . 203 VGC Vinylester Glass Capsule . . . . . . . . . . . 79 GDP Gas Pins . . . . . . . . . . . . . . . . . . . . . . . 183 WA Wedge-All Anchor . . . . . . . . . . . . . . . 133 GDPS Gas Pins . . . . . . . . . . . . . . . . . . . . . . 185 PHD Hammer Drive Pin . . . . . . . . . . . . . . . 207 PHT Hammer Drive . . . . . . . . . . . . . . . . . . 207 ZN Nailon (zinc) . . . . . . . . . . . . . . . . . . . . . 171 NEW GDPSK Gas Pins . . . . . . . . . . . . . . . . . . . . 186
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
ALLOWABLE TENSION LOAD 1,2 Solid Brick Hollow Brick 500 lbs (2.2 kN) or less 500 lbs 2,000 lbs (2.2 kN) to (8.9 kN) 2,000 lbs or greater (8.9 kN) CODE RECOGNITION 1
SET-XP SET and ET-HP (formerly ET) EDOT Acrylic-Tie VGC (Hammer Capsule) Strong-Bolt 2 Strong-Bolt Titen HD Titen HD Mini Titen HD Rod Hanger Titen HD Rod Coupler Torq-Cut Anchor
16 22, 37 47 53 79 96 106 110 122 123 127 129 133 133 146 150 157 161 162 166 168 170 171 172 172 173 174 175 176 177 183 201
(Including Cracked)
(Including Cracked)
(Including Cracked)
Wedge-All Tie Wire Wedge-All Sleeve-All Drop-In Blue Banger Hanger Easy-Set Expansion Anchor Titen Concrete and Masonry Screw
Florida
Crimp Anchor Split Drive Anchor Nailon Zinc or Nylon Lag Screw Expansion Shield Expansion Screw Anchor Machine Screw Anchor Hollow Wall Anchors Plastic Wall Anchor Sure Wall and Sure Wall Toggle Spring Wing Toggle Bolt Gas Pins Powder-Actuated Fasteners
Factory Mutual
ICC-ES, Florida ICC-ES; City of L.A.; Florida; Factory Mutual
1. Load values and code listings may not be available for all base materials cited in the table. To verify code listed applications refer to the code report at www.strongtie.com or contact SimpsonStrongTie Company Inc. at 1 (800) 999-5099 (U.S. and Canada). 2. For Strength Design (SD), reference SD performance data in this catalog.
ICC-ES; Florida; NSF 61; City of L.A.; Various DOT ICC-ES; City of L.A.; Florida; Various DOT; NSF 61 (SET) Various DOT ICC-ES; City of L.A.; Florida; NSF 61; Various DOT Various DOT ICC-ES, City of L.A.; Underwriters Laboratories; Factory Mutual` ICC-ES; City of L.A.; Florida ICC-ES; City of L.A.; Florida; Factory Mutual
ICC-ES pending ICC-ES; City of L.A.; Florida; Underwriters Laboratories; Factory Mutual
City of L.A.; Underwriters Laboratories; Factory Mutual Underwriters Laboratories; Factory Mutual
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Anchoring Adhesives Acrylic Anchoring Adhesive Adhesive Accessories Vinylester Anchoring Adhesive Crack Repair Adhesives Mechanical Anchors
1551
5271
7278
7983
8494
Every day we work hard to earn your business, blending the talents of our people with the quality of our products and services to exceed your expectations.
95177
Gas and 178214 Powder-Actuated Fastening Systems Carbide Drill Bits and Chisels
Karen Colonias
Terry Kingsfather
President
215223
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Limited Warranty
SimpsonStrongTie Company Inc. warrants catalog products to be free from substantial defects in material or manufacturing. SimpsonStrongTie Company Inc. products are further warranted for adequacy of design when used in accordance with design limits in this catalog and when properly specied, installed, and maintained. This warranty does not apply to uses not in compliance with specic applications and installation procedures set forth in this catalog, or to non-catalog or modied products, or to deterioration due to environmental conditions. SimpsonStrongTie products are designed to enable structures to resist the movement, stress, and loading that results from impact events such as earthquakes and high velocity winds. SimpsonStrongTie products are designed to the load capacities and uses listed in this catalog. Properly-installed SimpsonStrongTie products will perform substantially in accordance with the specications set forth on the website or in the applicable SimpsonStrongTie catalog. Additional performance limitations for specic products may be listed on the applicable catalog pages. Due to the particular characteristics of potential impact events, the specic design and location of the structure, the building materials used, the quality of construction, and the condition of the soils involved, damage may nonetheless result to a structure and its contents even if the loads resulting from the impact event do not exceed SimpsonStrongTie catalog specications and SimpsonStrongTie products are properly installed in accordance with applicable building codes. All warranty obligations of SimpsonStrongTie Company Inc. shall be limited, at the discretion of SimpsonStrongTie Company Inc., to repair or replacement of the defective part. These remedies shall constitute SimpsonStrongTie Company Inc.s sole obligation and sole remedy of purchaser under this warranty. In no event will SimpsonStrongTie Company Inc. be responsible for incidental, consequential, or special loss or damage, however caused. This warranty is expressly in lieu of all other warranties, expressed or implied, including warranties of merchantability or tness for a particular purpose, all such other warranties being hereby expressly excluded. This warranty may change periodically consult our website (www.strongtie.com) for current information.
Warning
SimpsonStrongTie Company Inc. structural connectors, anchors and other products are designed and tested to provide specied design loads. To obtain optimal performance from SimpsonStrongTie Company Inc. products and achieve maximum allowable design load and design strength, the products must be properly installed and used in accordance with the installation instructions and design limits provided by SimpsonStrongTie Company Inc. To ensure proper installation and use, designers and installers must carefully read the following General Notes, General Instructions for the Installer and General Instructions for the Designer as well as consult the applicable catalog pages for specic product installation instructions and notes. If you do not understand the catalog, or if you have any questions, contact SimpsonStrongTie Company Inc. for further information.
10
should consult the SimpsonStrongTie Company Inc. web site at www.strongtie.com to obtain additional design and installation information. Failure to follow fully all of the notes and instructions provided by SimpsonStrongTie Company Inc. may result in improper design or installation of products. Improperly designed or installed products may not perform to the specications set forth in this catalog and may reduce a structures ability to resist the movement, stress and loading that occurs from gravity loads as well as impact events such as earthquakes and high velocity winds. SimpsonStrongTie Company Inc. does not guarantee the performance or safety of products that are modied, improperly installed, or not used in accordance with the design and load limits set forth in this catalog.
In addition to following all notes, warnings and instructions provided in the catalog, installers, designers, engineers and consumers
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Technical Support
When you call for engineering technical support, we can help you if you have the following information at hand. This will help us to serve you promptly and efciently. What SimpsonStrongTie catalog are you using? (See the front cover for the form number). Which SimpsonStrongTie product are you considering? What are the design requirements? (e.g. loads, anchor diameter, base material, edge/spacing distance, etc.).
For the most up-to-date information about our products, visit our website at: www.strongtie.com
Our toll-free technical support number is (800) 999-5099
This catalog reects changes in the loads and congurations of some SimpsonStrongTie Company Inc. products. This catalog is effective until December 31, 2013, and supersedes all information in all earlier publications, including catalogs, brochures, iers, technical bulletins, etc. Information on loads and congurations is updated periodically.
Corrosion Information
Understanding The Issues
Metal fasteners and anchors will corrode and may lose load-carrying capacity when installed in corrosive environments or exposed to corrosive materials. There are many environments and materials which may cause corrosion including ocean-salt air, re retardants, fumes, fertilizers, preservative-treated wood, de-icing salts, dissimilar metals, and other corrosive elements. The many variables present in a single building environment make it impossible to accurately predict if, or when, signicant corrosion will begin or reach a critical level. This relative uncertainty makes it crucial that Designers and users be knowledgeable of the potential risks and select a product coating or metal suitable for the intended use. It is also important that regular maintenance and periodic inspections are performed, especially for outdoor applications. It is common to see some corrosion especially in outdoor applications. Even stainless steel can corrode. The presence of some corrosion does not mean that load capacity has necessarily been affected or that a failure will occur. If signicant corrosion is apparent or suspected, then the wood, anchors and fasteners should be inspected by a qualied professional engineer or qualied general contractor and may need to be replaced. Preservative-treated wood formulations have changed signicantly, and some of the new formulations are more corrosive to anchors and fasteners than the traditionally used formulation of CCAC. Simpson Strong-Tie testing has shown that ACQC, ACQD (Carbonate) and CAB treated woods are approximately two times more corrosive than CCAC, while SBXDOT (Sodium Borate) treated woods were shown to be less corrosive than CCA-C. (See technical bulletin TPTWOOD for details). Due to the many different preservative-treatment formulations, uctuating retention levels, moisture content, and because the formulations may vary regionally, or change without warning, understanding which anchors or fasteners to use with these materials has become a complex task. We have attempted to provide basic knowledge on the subject here, but it is important to fully educate yourself by reviewing our technical bulletins on the topic, and also by viewing information and literature provided by others. Additionally, because the issue is evolving it is important to get the very latest information on the topic by visiting our website at www.strongtie.com/info. Types 304/316 stainless steel are the most effective options to mitigate corrosion risk. However, they are more expensive and sometimes more difcult to obtain. To best serve our customers, Simpson Strong-Tie Company Inc. is evaluating the options to identify the safest and most cost-effective solutions. Based on our testing and experience, there are some specic applications that are appropriate for zinc-plated, mechanically galvanized (Class 55 and 65), hot-dip galvanized, Type 410 stainless steel with a protective top coat, and Type 304/316 stainless-steel anchors or fasteners (see page 12).
11
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Corrosion Information
General SimpsonStrongTie Recommendations
Outdoor environments are generally more corrosive to steel. If you choose to use mechanically galvanized (Class 55 and 65) on an outdoor project, you should periodically inspect your anchors and fasteners or have a professional inspection performed. Regular maintenance including water-proong of the wood used in your outdoor project is also a good practice. For wood with actual retention levels greater than 0.40 pcf for ACQ, 0.34 for MCQ, 0.21 pcf for CA-B, 0.15 pcf for CA-C and MCA or 0.14 pcf for CA-C (Ground Contact), stainless-steel anchors and fasteners are recommended. Verify actual retention level with the wood treater. Testing indicates wood installed dry reduces potential corrosion. If dry wood is used, see our website for additional information. Due to the many variables involved, Simpson Strong-Tie Company Inc. cannot provide estimates on service life of connectors, anchors or fasteners. We suggest that all users and Speciers also obtain recommendations for mechanically galvanized (Class 55 and 65) or other coatings from the treated-wood supplier for the type of wood used. However, as long as Simpson Strong-Tie Company Inc. recommendations are followed, Simpson Strong-Tie Company Inc. stands behind its product performance and our standard warranty (page 10) applies.
indoor dry environments are less corrosive than outdoor environments. Determining the type of environment where an anchor or a fastener will be used is an important factor in selecting the most appropriate material and coating for anchor or fastener use. To help in your decision making, consider the following general exposure information: Interior Dry Use: Includes wall and ceiling cavities, and raised floor applications in enclosed buildings that have been designed to ensure that condensation and other sources of moisture do not develop. Exterior: Includes outdoor construction in conditions other than Higher Exposure Use. Higher Exposure Use: Includes exposure to ocean salt air, de-icing salts, fire retardants, large bodies of water (e.g. dock boards), fumes, fertilizers, soil, some preservative-treated woods, industrial zones, acid rain, and other corrosive elements. wood and other common building materials, additional corrosion risk caused by the fastened material is not a significant factor. Although when fastening dissimilar metals carefully consider the correct combination of fastener and material necessary to avoid galvanic corrosion. For
4. Familiarize yourself with the preservative-treated wood to be fastened. The preservative-treated-wood supplier should provide all
of the pertinent information about the wood being used. This information should include the specific type of wood treatment used, if ammonia was used in the treatment and the chemical retention level. If this information is not available, then Simpson Strong-Tie Company Inc. recommends the use of types 304 or 316 stainless steel. It is also advisable to obtain a recommendation from the treated-wood supplier for a fastener coating or material that is suitable for use with their formulation in the intended environment. If this recommendation differs from those shown in the table below, Simpson Strong-Tie Company Inc. recommends that the most conservative recommendation be followed.
5. Use the chart below, which is based on Simpson Strong-Tie testing and experience, to select the anchor or fastener coating or material. If the material or preservative-treated wood product to be used is
not shown on the chart, Simpson Strong-Tie has not evaluated it and cannot make any other recommendation than the use of coatings/materials shown in the high category shown below. Manufacturers may independently provide test results or other product use information; Simpson Strong-Tie Company Inc. expresses no opinion regarding such information.
1. Wood with actual retention levels greater than 0.40 pcf for ACQ, 0.34 for MCQ, 0.21 pcf for CA-B, 0.15 pcf for CA-C and MCA or 0.14 pcf for CA-C (Ground Contact), stainless-steel anchors and fasteners are recommended. Verify actual retention level with the wood treater. 2. Borate treated woods are not appropriate for outdoor use. 3. Test results indicate that hot-dip galvanized and mechanically galvanized (class 55 and 65) will perform adequately, subject to regular maintenance and periodic inspection. However, the test protocol followed was a modified version of the nationally recognized test method AWPA E12-94. This test method is an accelerated test, so data over an extended period of time is not available. Also noteworthy is that tests run in a laboratory may not correlate to service conditions. If uncertain, use types 304/316 stainless steel. Some treated wood may have excess surface chemicals making it potentially more corrosive. If you suspect this or are uncertain, use types 304/316 stainless steel. Ammonia is typically used as a chemical carrier for difficult to treat wood species, such as, but not exclusive to, Douglas Fir and Hem Fir, which are usually found in the western United States. Amine carriers are used in some of the eastern species, such as Southern Yellow Pine. If uncertain, verify chemical with wood treater.
Environment
Preservative-Treated Wood Untreated ACQ-C, ACQ-D (Carbonate), Other Wood or SBX/DOT CA-B, CA-C/ CA-C ACZA or MCQ/ 4. Other & Zinc Higher Uncertain With Material Borate MCA Without Chemical Ammonia Ammonia Content 5. Low Low Low Med Med High High High Med High High N/A2 N/A2 High2 Med3,4 Med3,4 High High High High High High High High High High High High High High High High
6. Type 316 stainless-steel fasteners are the minimum recommendation for ocean-salt air and other chloride environments. 7. Mechanically galvanized Titen HD Anchors are only recommended for temporary exterior applications. For the latest Simpson Strong-Tie coating information and additional technical information on this topic, visit our website at www.strongtie.com/info.
12
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Threaded Rod
Rebar
Normal-Weight Concrete
Lightweight Concrete
Steel
Tension Load
Shear Load
Oblique Load
Edge Distance
Spacing
General Notes
These general notes are provided to ensure proper installation of SimpsonStrongTie Company Inc products and must be followed fully. a. SimpsonStrongTie Company Inc. reserves the right to change specications, designs, and models without notice or liability for such changes. b. Unless otherwise noted, dimensions are in inches and loads are in pounds. c. Do not overload, which will jeopardize the anchorage. Service loads shall not exceed published allowable loads. Factored loads shall not exceed design strengths calculated in accordance with published design data. d. Some hardened fasteners may experience premature failure if exposed to moisture. These fasteners are recommended to be used in dry interior applications. e. Do not weld products listed in this catalog. Some steel types have poor weldability and a tendency to crack when welded.
13
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
These general instructions for the designer are provided to ensure the proper selection and installation of SimpsonStrongTie Company Inc. products and must be followed carefully. These general instructions are in addition to the specic design and installation instructions and notes provided for each particular product, all of which should be consulted prior to and during the design process. a. The term Designer used throughout this catalog is intended to mean a licensed/certied building design professional, a licensed professional engineer, or a licensed architect. b. All connected members and related elements shall be designed by the Designer and must have sufcient strength (bending, shear, etc) to resist the loads imposed by the anchors. c. When the allowable stress design method is used, the design service loads shall not exceed the published allowable loads reduced by load-adjustment factors for temperature, spacing and edge distance as applicable. l. Mechanical anchors should not be installed into concrete that is less than 7 days old. The allowable loads and design strengths of mechanical anchors that are installed into concrete less than 28 days old should be based on the actual compressive strength of the concrete at the time of installation. m. Nominal embedment depth (embedment depth) is the distance from the surface of the base material to the installed end of the anchor and is measured prior to application of an installation torque (if applicable). Effective embedment depth is the distance from the surface of the base material to the deepest point at which the load is transferred to the base material.
d. When the strength design method is used, reduced by loadn. Drill bits shall meet the diameter requirements of ANSI B212.15. adjustment factors for temperature, spacing, and edge distance, as For adhesive anchor installations in oversized holes, see applicable, the factored loads shall not exceed the design strengths Supplemental Topic A1. For adhesive anchor installations into corecalculated in accordance with the published design data. drilled holes, see Supplemental Topic A2. e. SimpsonStrongTie strongly recommends the following addition o. Threaded-rod inserts for adhesive anchors shall be UNC fully to construction drawings and specications: SimpsonStrongTie threaded steel. products are specically required to meet the structural calculations p. Allowable loads and design strengths are generally based on testing of plan. Before substituting another brand, conrm load capacity of adhesive anchors installed into dry holes. For installations in damp, based on reliable published testing data or calculations. The wet and submerged environments, see Supplemental Topic A3. Engineer/Designer of Record should evaluate and give written approval for substitution prior to installation. q. Adhesive anchors should not be installed into concrete that is f. Local and/or regional building codes may require meeting special conditions. Building codes often require special inspections of anchors installed in concrete or masonry. For compliance with these requirements, it is necessary to contact the local and/ or regional building authority. Except where mandated by code, SimpsonStrongTie products do not require special inspection. less than 7 days old. The allowable loads and design strengths of adhesive anchors that are installed into concrete less than 28 days old should be based on the actual compressive strength of the concrete at the time load is applied.
h. Unless stated otherwise, tests conducted to derive performance information were performed in members with minimum thickness equal to 1.5 times the anchor embedment depth. Anchoring into thinner members requires the evaluation and judgment of a qualied Designer.
s. Anchors are permitted to support re-resistive construction provided at least one of the following conditions is fullled: a) Anchors are used to resist wind or seismic forces only; b) Anchors that support gravity load-bearing structural elements are within a re-resistance-rated envelope or a re-resistancerated membrane, are protected by approved re-resistance rated materials, or have been evaluated for resistance to re exposure in accordance with recognized standards; c) Anchors are used to support nonstructural elements.
t. Some adhesives are not qualied for resisting long-term sustained loads. These adhesives are for resisting short-term loads such as wind or seismic loads only. See Supplemental Topic A5. i. Tests are conducted with anchors installed perpendicular (6 from a vertical reference) from a vertical reference to the surface of the u. Exposure to some chemicals may degrade the bond strength base material. Deviations can result in anchor bending stresses and of adhesive anchors. Refer to the product description for reduce the load carrying capacity of the anchor. chemical resistance information. Information is also available j. Allowable loads and design strengths do not consider bending stresses due to shear loads applied with large eccentricities. k. Metal anchors and fasteners will corrode and may lose loadcarrying capacity when installed in corrosive environments or exposed to corrosive materials. See Supplemental Topic G3. in SimpsonStrongTie Company Inc. Technical Bulletin T-SAS-CHEMRES.
14
g. Allowable loads and design strengths are determined from test results, calculations, and experience. These are guide values for sound base materials with known properties. Due to variation in base materials and site conditions, site-specic testing should be conducted if exact performance in a specic base material at a specic site must be known.
r. Adhesive anchors can be affected by elevated base material temperature. See Supplemental Topic A4.
Ideal for anchoring threaded rod, rebar and smooth dowels in a variety of base materials, epoxy-based anchoring adhesives offer strength and versatility across a wide variety of applications. Simpson Strong-Tie epoxy adhesives meet or are rigorously tested to meet 2009 IBC requirements for both cracked and uncracked concrete applications. As you would expect, Simpson Strong-Tie offers all the high-strength dispensing tools and other important accessories to increase productivity on any project.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET-XP
Epoxy Adhesives
IBC
2009
ESR-2508
Cure Schedule
Base Material Temperature F 50 60 70 90 110 C 10 16 21 32 43 Gel Time (mins.) 75 60 45 35 20 Cure Time (hrs.) 72 48 24 24 24
16
PropertY Test MetHoD ResuLts Consistency ASTM C881 Passed, non-sag Glass transition temperature ASTM E1356 155F Bond strength (moist cure) ASTM C882 3,742 psi at 2 days Water absorption ASTM D570 0.10% Compressive yield strength ASTM D695 14,830 psi Compressive modulus ASTM D695 644,000 psi Gel time ASTM C881 49 minutes CHemicaL Resistance: Very good to excellent against distilled water, in-organic acids and alkalis. Fair to good against organic acids and alkalis, and many organic solvents. Poor against ketones. For more detailed information visit our website or contact SimpsonStrongTie.
SuGGesteD SpeciFication: Anchoring adhesive shall be a two-component high-solids, epoxy-based system supplied in manufacturers standard cartridge and dispensed through a staticmixing nozzle supplied by the manufacturer. The adhesive anchor shall have been tested and qualied for performance in cracked and uncracked concrete per ICC-ES AC308. Adhesive shall be SET-XP adhesive from SimpsonStrongTie, Pleasanton, CA. Anchors shall be installed per SimpsonStrongTie instructions for SET-XP epoxy adhesive. Accessories: See pages 7277 for information on dispensing tools, mixing nozzles and other accessories.
IMPORTANT See Pages 7071 for Installation Instructions
SET-XP is a 1:1 two-component, high-solids, epoxy-based anchoring adhesive formulated for optimum performance in both cracked and uncracked concrete. SET-XP adhesive has been rigorously tested in accordance with ICC-ES AC308 and 2009 IBC requirements and has proven to offer increased reliability in the most adverse conditions, including performance in cracked concrete under static and seismic loading. SET-XP adhesive is teal in color in order to be identied as a high-performance adhesive for adverse conditions. Resin and hardener are dispensed and mixed simultaneously through the mixing nozzle. SET-XP adhesive exceeds the ASTM C881 specication for Type I and Type IV, Grade 3, Class C epoxy. Uses: When SET-XP adhesive is used with all threaded rod or rebar, the system can be used in tension and seismic zones where there is a risk of cracks occurring that pass through the anchor location. It is also suitable for uncracked concrete conditions. CoDes: ICC-ES ESR-2508; City of L.A. pending; Florida FL 11506.5 NSF/ANSI Standard 61 (216 in21000 gal). The load tables list values based upon results from the most recent testing and may not reect those in current code reports. Where code jurisdictions apply, consult the current reports for applicable load values. AppLication: Surfaces to receive epoxy must be clean. The base-material temperature must be 50 F or above at the time of installation. For best results, material should be 7080 F at the time of application. Cartridges should not be immersed in water to facilitate warming. To warm cold material, the cartridges should be stored in a warm, uniformly-heated area or storage container for a sufcient time to allow epoxy to warm completely. Mixed material in nozzle can harden in 57 minutes at a temperature of 40 F or above. DesiGn ExampLe: See pages 231, 235237 InstaLLation: See pages 7071 SHeLF LiFe: 24 months from date of manufacture in unopened sideby-side cartridge. StoraGe ConDitions: For best results, store between 4590 F. To store partially used cartridges, leave hardened nozzle in place. To re-use, attach new nozzle. CoLor: Resin white, hardener black-green. When properly mixed, SET-XP adhesive will be a uniform teal color. CLean Up: Uncured material Wipe up with cotton cloths. If desired, scrub area with abrasive, waterbased cleaner and ush with water. If approved, solvents such as ketones (MEK, acetone, etc.), lacquer thinner or adhesive remover can be used. DO NOT USE SOLVENTS TO CLEAN ADHESIVE FROM SKIN. Take appropriate precautions when handling ammable solvents. Solvents may damage surfaces to which they are applied. Cured Material chip or grind off surface. Test Criteria: Anchors installed with SET-XP adhesive have been tested in accordance with ICC-ESs Acceptance Criteria for Post-Installed Adhesive Anchors in Masonry Elements (AC58) and Adhesive Anchors in Concrete Elements (AC308) for the following: Seismic and wind loading in Long-term creep at elevatedcracked and uncracked concrete temperatures and uncracked masonry Static loading at elevated Static tension and shear loading temperatures in cracked and uncracked Damp holes concrete and uncracked Freeze-thaw conditions masonry
SET-XP 10
SET-XP 22
SET-XP 56
EMN22i
EDT22S
EMN22i
1. Cartridge estimation guides are available on pages 4851. 2. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available on pages 7277. 3. Use only appropriate SimpsonStrongTie mixing nozzle in accordance with SimpsonStrongTie instructions. Modification or improper use of mixing nozzle may impair epoxy performance.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET-XP
SET-XP Epoxy Anchor Installation Information and Additional Data for Threaded Rod and Rebar in Normal-Weight Concrete1
Characteristic Drill Bit Diameter Maximum Tightening Torque Permitted Embedment Depth Range2 Minimum Concrete Thickness Critical Edge Distance Minimum Edge Distance Minimum Anchor Spacing Minimum Maximum Symbol dhole Tinst hef hef hmin cac cmin smin 8 / #3 Installation Information 1 in. 2 ft-lb 10 in. 238 in. 712 in. in. in. in.
3
Units
Nominal Anchor Diameter (in.) / Rebar Size 12 / #4 58 / #5 34 / #6 78 / #7 1 / #8 58 20 234 10 34 30 318 1212 78 45 312 15 hef + 5do 3 x hef 134 3 1 60 334 1712 118 80 4 20
Epoxy Adhesives
234 6
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308. 2. Minimum and maximum embedment depths are are listed in accordance with ICC-ES AC308 requirements.
SET-XP Epoxy Anchor Tension Strength Design Data for Threaded Rod in Normal-Weight Concrete1,12
3 8 12 Steel Strength in Tension in2 0.078 0.142 0.226 0.334 Minimum Tensile Stress Area Ase 9,750 17,750 28,250 41,750 Tension Resistance of Steel - ASTM A193, Grade B7 - ASTM F1554, Grade 36 4,525 8,235 13,110 19,370 Threaded lb. Nsa - Type 410 Stainless (ASTM A193, Grade B6) 8,580 15,620 24,860 36,740 Rod - Type 304 and 316 Stainless (ASTM A193, Grade B8 4,445 8,095 12,880 19,040 and B8M) Strength Reduction Factor - Steel Failure 0.759 15 Concrete Breakout Strength in Tension (2,500 psi f'c 8,000 psi) Effectiveness Factor - Uncracked Concrete kuncr 24 Effectiveness Factor - Cracked Concrete kcr 17 Strength Reduction Factor - Breakout Failure 0.6511 Bond Strength in Tension (2,500 psi f'c 8,000 psi)15 8 Characteristic Bond Strength psi 1,510 2,250 2,075 1,905 k,uncr Temp. Range 1 for Uncracked Minimum 238 234 318 312 hef in 1 1 Concrete2,4,5 Permitted Embedment Depth Range Maximum 7 2 10 12 2 15 psi 1,165 995 855 760 k,cr Temp. Range 1 Characteristic Bond Strength8,13,14 for Cracked Minimum 3 4 5 6 hef in Concrete2,4,5 Permitted Embedment Depth Range Maximum 712 10 1212 15 psi 780 1,160 1,070 980 k,uncr Temp. Range 2 Characteristic Bond Strength6,8 for Uncracked Minimum 238 234 318 312 hef in Concrete3,4,5 Permitted Embedment Depth Range Maximum 712 10 1212 15 psi 600 515 440 390 k,cr Temp. Range 2 Characteristic Bond Strength6,8,13,14 for Cracked Minimum 3 4 5 6 hef in Concrete3,4,5 Permitted Embedment Depth Range Maximum 712 10 1212 15 Bond Strength in Tension Bond Strength Reduction Factors for Continuous Special Inspection dry, ci Strength Reduction Factor - Dry Concrete 0.6510 sat, ci Strength Reduction Factor - Water-saturated Concrete 0.4510 Ksat, ci Additional Factor for Water-saturated Concrete7 0.57 Bond Strength in Tension Bond Strength Reduction Factors for Periodic Special Inspection dry, pi Strength Reduction Factor - Dry Concrete 0.5510 sat, pi Strength Reduction Factor - Water-saturated Concrete 0.4510 Ksat, pi Additional Factor for Water-saturated Concrete7 0.48
Characteristic
Symbol Units
0.606 0.969 75,750 121,125 35,150 56,200 66,660 106,590 34,540 55,235
1,730 334 1712 700 7 1712 895 334 1712 360 7 1712
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modified below. 2. Temperature Range 1: Maximum short-term temperature of 110F (43C). Maximum long-term temperature of 75F (24C). 3. Temperature Range 2: Maximum short-term temperature of 150F (66C). Maximum long-term temperature of 110F (43C). 4. Short-term concrete temperatures are those that occur over short intervals (diurnal cycling). 5. Long-term concrete temperature are constant temperatures over a significant time period. 6. For anchors that only resist wind or seismic loads, bond strengths may be increased by 72%. 7. In water-saturated concrete, multiply k,uncr and k,cr by Ksat. 8. For anchors installed in overhead and subjected to tension resulting from sustained loading, multiply the value calculated for Na according to ICC-ES AC308 by 0.75. 9. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of .
10. T he value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 11. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition A are met, refer to Section D.4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 12. S and-lightweight and all-lightweight concrete are beyond the scope of this table. 13. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, the bond strength values for 78" anchors must be multiplied by N,seis = 0.80. 14. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, the bond strength values for 1" anchors must be multiplied by N,seis = 0.92 15. T he values of f'c used for calculation purposes must not exceed 8000 psi (55.1 MPa) for uncracked concrete. The value of f'c used for calculation purposes must not exceed 2,500 psi (17.2 MPa) for tension resistance in cracked concrete.
17
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET-XP
Epoxy Adhesives
SET-XP Epoxy Anchor Tension Strength Design Data for Rebar in Normal-Weight Concrete1,12
#3 #4 #5 Steel Strength in Tension Minimum Tensile Stress Area Ase in2 0.11 0.20 0.31 0.44 Tension Resistance of Steel - Rebar (ASTM A615, Grade 60) Nsa lb. 9,900 18,000 27,900 39,600 Rebar Strength Reduction Factor - Steel Failure 0.659 Concrete Breakout Strength in Tension (2,500 psi f'c 8,000 psi)15 Effectiveness Factor - Uncracked Concrete kuncr 24 Effectiveness Factor - Cracked Concrete kcr 17 Strength Reduction Factor - Breakout Failure 0.6511 Bond Strength in Tension (2,500 psi f'c 8,000 psi)15 psi 1600 k,uncr Temp. Range 1 Characteristic Bond Strength8 for Uncracked Minimum 238 234 318 312 Permitted Embedment Depth Range hef in Concrete2,4,5 Maximum 712 10 1212 15 psi 1,165 995 855 760 k,cr Temp. Range 1 Characteristic Bond Strength8,13,14 for Cracked Minimum 3 4 5 6 Permitted Embedment Depth Range hef in Concrete2,4,5 Maximum 712 10 1212 15 psi 825 k,uncr Temp. Range 2 Characteristic Bond Strength6,8 for Uncracked Minimum 238 234 318 312 Permitted Embedment Depth Range hef in 1 1 Concrete3,4,5 Maximum 7 2 10 12 2 15 psi 600 515 440 390 k,cr Temp. Range 2 Characteristic Bond Strength6,8,13,14 for Cracked Minimum 3 4 5 6 Permitted Embedment Depth Range hef in Concrete3,4,5 Maximum 712 10 1212 15 Bond Strength in Tension - Bond Strength Reduction Factors for Continuous Special Inspection Strength Reduction Factor - Dry Concrete 0.6510 dry, ci Strength Reduction Factor - Water-saturated Concrete 0.4510 sat, ci 7 Ksat, ci Additional Factor for Water-saturated Concrete 0.57 Bond Strength in Tension - Bond Strength Reduction Factors for Periodic Special Inspection Strength Reduction Factor - Dry Concrete 0.5510 dry, pi Strength Reduction Factor - Water-saturated Concrete 0.4510 sat, pi Ksat, pi Additional Factor for Water-saturated Concrete7 0.48
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modified below. 2. Temperature Range 1: Maximum short-term temperature of 110F (43C). Maximum long-term temperature of 75F (24C). 3. Temperature Range 2: Maximum short-term temperature of 150F (66C). Maximum long-term temperature of 110F (43C). 4. Short-term concrete temperatures are those that occur over short intervals (diurnal cycling). 5. Long-term concrete temperature are constant temperatures over a significant time period. 6. For anchors that only resist wind or seismic loads, bond strengths may be increased by 72%. 7. In water-saturated concrete, multiply k,uncr and k,cr by Ksat. 8. For anchors installed in overhead and subjected to tension resulting from sustained loading, multiply the value calculated for Na according to ICC-ES AC308 by 0.75. 9. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of .
Characteristic
Symbol Units
4 20 675 8 20 4 20 350 8 20
5 25 675 10 25 5 25 350 10 25
18
10. T he value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 11. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition A are met, refer to Section D.4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 12. S and-lightweight and all-lightweight concrete are beyond the scope of this table. 13. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, the bond strength values for #7 rebar anchors must be multiplied by N,seis = 0.80. 14. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, the bond strength values for #8 rebar anchors must be multiplied by N,seis = 0.92 15. T he values of f'c used for calculation purposes must not exceed 8000 psi (55.1 MPa) for uncracked concrete. The value of f'c used for calculation purposes must not exceed 2,500 psi (17.2 MPa) for tension resistance in cracked concrete.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET-XP
SET-XP Epoxy Anchor Shear Strength Design Data for Threaded Rod in Normal-Weight Concrete1,5
Characteristic Symbol Units
3
Epoxy Adhesives
Nominal Anchor Diameter (in.) 12 58 34 78 1 0.462 34,650 16,080 30,490 0.606 45,450 21,090 40,000
Steel Strength in Shear Minimum Shear Stress Area Ase in2 Shear Resistance of Steel - ASTM A193, Grade B7 - ASTM F1554, Grade 36 Vsa6 lb. - Type 410 Stainless (ASTM A193, Grade B6) - Type 304 and 316 Stainless (ASTM A193, Grade B8 and B8M) Threaded Rod Reduction for Seismic Shear - ASTM F1554, Grade 366 Reduction for Seismic Shear - ASTM A193, Grade B76 Reduction for Seismic Shear - Stainless (ASTM A193, Grade B6)6 V,seis
0.078 0.142 0.226 0.334 4,875 10,650 16,950 25,050 2,260 4,940 7,865 11,625 4,290 9,370 14,910 22,040 2,225 0.87 0.87 0.69 4,855 0.78 0.78 0.82 0.82
7,730 11,420 15,800 20,725 33,140 0.68 0.68 0.75 0.75 0.68 0.68 0.75 0.75 0.652 0.68 0.68 0.75 0.75 0.68 0.68 0.83 0.83 0.65 0.65 0.72 0.72
Reduction for Seismic Shear - Stainless (ASTM A193, Grade B8 0.69 and B8M)6 Strength Reduction Factor - Steel Failure Concrete Breakout Strength in Shear in. 0.375 Outside Diameter of Anchor do Load Bearing Length of Anchor in Shear Strength Reduction Factor - Breakout Failure Coefcient for Pryout Strength Strength Reduction Factor - Pryout Failure in. e Concrete Pryout Strength in Shear kcp
0.500
0.625
0.875
1.000
1.250
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of AC 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 3. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition A are met, refer to Section D.4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of .
4. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 5. Sand-lightweight and all-lightweight concrete are beyond the scope of this table. 6. The values of Vsa are applicable for both cracked and uncracked concrete. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, Vsa must be multiplied by V,seis for the corresponding threaded rod steel type.
SET-XP Epoxy Anchor Shear Strength Design Data for Rebar in Normal-Weight Concrete1,5
#3 Steel Strength in Shear Minimum Shear Stress Area Ase in2 0.11 6 (ASTM lb. 4,950 Shear Resistance of Steel - Rebar A615, Grade 60) Vsa Rebar 0.85 Reduction for Seismic Shear - Rebar (ASTM A615, Grade 60)6 V,seis Strength Reduction Factor - Steel Failure Concrete Breakout Strength in Shear in. 0.375 Outside Diameter of Anchor do Load Bearing Length of Anchor in Shear Strength Reduction Factor - Breakout Failure Coefcient for Pryout Strength Strength Reduction Factor - Pryout Failure Characteristic Symbol Units #4 0.20 10,800 0.88 #5 0.31 16,740 0.84 Rebar Size #6 0.44 23,760 0.84 0.602 0.750 hef 0.703 2.0 0.704 #7 0.60 32,400 0.77
0.500
0.625
0.875
1.000
1.250
in.
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of AC 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 3. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition A are met, refer to Section D.4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of .
4. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 5. Sand-lightweight and all-lightweight concrete are beyond the scope of this table. 6. The values of Vsa are applicable for both cracked and uncracked concrete. For anchors installed in regions assigned to Seismic Design Category C, D, E or F, Vsa must be multiplied by V,seis.
19
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET-XP
Epoxy Adhesives
Tension and Shear Loads for Threaded Rod and Rebar Anchors in 8-inch Lightweight,Medium-Weight and Normal-Weight Grout Filled CMU
Rod Dia. in. (mm) Drill Bit Dia. in. Min. Embed. Depth in. (mm) Critical Critical Edge Dist. End Dist. in. in. (mm) (mm) Critical Spacing Dist. in. (mm) 8-inch Grout Filled CMU Allowable Loads Based on CMU Strength Tension Ultimate lbs. (kN) 7,441 (33.1) 9,125 (40.6) 9,618 (42.8) 9,480 (42.2) Allowable lbs. (kN) 1,490 (6.6) 1,825 (8.1) 1,895 (8.4) 1,895 (8.4) Shear Ultimate lbs. (kN) 5,721 (25.4) 6,997 (31.1) 6,887 (30.6) 6,747 (30.0) Allowable lbs. (kN) 1,145 (5.1) 1,350 (6.0) 1,350 (6.0) 1,350 (6.0)
Threaded Rod Anchors Installed on the Face of the CMU Wall (see Figure 1) 8 (9.5)
3
12 58 34 78
Rebar Anchors Installed on the Face of the CMU Wall (see Figure 1) #3 (9.5) #4 (12.7) #5 (15.9) 12 58 34 338 (86) 412 (114) 558 (143) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 8 (203) 8 (203) 8 (203) 6,982 (31.1) 9,167 (40.8) 10,925 (48.6) 1,395 (6.2) 1,835 (8.2) 2,185 (9.7) 7,299 (32.5) 8,144 (36.2) 7,530 (33.5) 1,460 (6.5) 1,505 (6.7) 1,505 (6.7)
4" Minimum end distance Critical end distance (see load table) No installation within 1" of head joint
Shaded Area = Placement for Full and Reduced Allowable Load Capacity in Grout-Filled CMU
1. Refer to temperature sensitivity chart for allowable bond strength reduction for temperature. See page 225 for more information. 2. Percent allowable load may be linearly interpolated for intermediate base material temperatures. 3. C = (F-32) / 1.8
20
1. Threaded rods must comply with ASTM F1554 Grade 36, Grade C minimum. Rebar must comply with ASTM A615, Grade 60 minimum. 2. Values for 8-inch wide concrete masonry units (CMU) with a minimum specified compressive strength of masonry, f'm, at 28 days is 1500 psi. 3. Embedment depth is measured from the outside face of the concrete masonry unit. 4. Allowable loads may be increased 3313% for short-term loading due to wind forces or seismic forces where permitted by code. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 7. Refer to allowable load-adjustment factors for end distance, edge distance and spacing on page 21.
Figure 1
4" minimum edge distance Critical edge distance (see load table)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET-XP
Load-Adjustment Factors for SET-XP Adhesive in Face of Wall Installation in 8" Grout-Filled CMU: End / Edge Distance and Spacing, Tension and Shear Loads
How to use these charts: 1. The following tables are for reduced end and edge distance and spacing. 2. Locate the anchor size to be used for either a tension and/or shear load application. 3. Locate the embedment (E) at which the anchor is to be installed. 4. Locate the end or edge distance (Cact) or spacing (Sact) at which the anchor is to be installed. 5. The load-adjustment factor (fc or fs) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple edges or spacing are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable tension or shear load based on CMU strength values only.
Epoxy Adhesives
3 38 12 4
4 12 12 4
5 58 12 4
6 12 12 4
0.91 1.00 1.00 1.00 0.93 1.00 1.00 1.00 0.96 1.00 1.00 1.00 0.98 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.96 0.88 0.88 0.97 0.91 0.91 0.98 0.94 0.94 0.99 0.97 0.97 1.00 1.00 1.00
End and Edge Distance Shear (fc) Shear Load Perpendicular to End or Edge
Dia.
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
3
*
#3 3 38 12 4 #4 4 12 12 4 #5 5 58 12 4
1. E = Embedment depth (inches). 2. C act = actual end or edge distance at which anchor is installed (inches). 3. C cr = critical end or edge distance for 100% load (inches). 4. Cmin = minimum end or edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual end or edge distance. 6. fccr = adjustment factor for allowable load at critical end or edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum end or edge distance. 8. fc = fcmin + [(1 - fcmin) (C act - Cmin) / (C cr - Cmin)].
#3 3 38 12 4
Cact (in)
E Ccr Cmin
3 38 12 4
4 12 12 4
5 58 12 4
6 12 12 4
3 38 12 4
4 12 12 4
5 58 12 4
6 12 12 4
fcmin 0.72 0.58 0.48 0.44 0.62 0.54 0.43 4 6 8 10 12 0.72 0.58 0.48 0.44 0.79 0.69 0.61 0.58 0.86 0.79 0.74 0.72 0.93 0.90 0.87 0.86 1.00 1.00 1.00 1.00 0.62 0.54 0.43 0.72 0.66 0.57 0.81 0.77 0.72 0.91 0.89 0.86 1.00 1.00 1.00 4 6 8 10 12
fcmin 0.94 0.87 0.87 0.85 0.84 0.82 0.82 0.94 0.87 0.87 0.85 0.96 0.90 0.90 0.89 0.97 0.94 0.94 0.93 0.99 0.97 0.97 0.96 1.00 1.00 1.00 1.00 0.84 0.82 0.82 0.88 0.87 0.87 0.92 0.91 0.91 0.96 0.96 0.96 1.00 1.00 1.00
*
2
5
#3 3 38 8 4
#4 4 12 8 4
#5 5 58 8 4
#3 3 38 8 4
#4 4 12 8 4
#5 5 58 8 4
3 38 8 4
4 12 8 4
5 58 8 4
6 12 8 4
3 38 8 4
4 12 8 4
5 58 8 4
6 12 8 4
fsmin 1.00 0.82 0.82 0.82 0.87 0.87 0.87 4 5 6 7 8 1.00 0.82 0.82 0.82 1.00 0.87 0.87 0.87 1.00 0.91 0.91 0.91 1.00 0.96 0.96 0.96 1.00 1.00 1.00 1.00 0.87 0.87 0.87 0.90 0.90 0.90 0.94 0.94 0.94 0.97 0.97 0.97 1.00 1.00 1.00 4 5 6 7 8
fsmin 1.00 1.00 1.00 1.00 0.91 0.91 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.91 0.91 1.00 0.93 0.93 1.00 0.96 0.96 1.00 0.98 0.98 1.00 1.00 1.00 1.00
2. S act = actual spacing distance at which anchors are installed (inches). 3. S cr = critical spacing distance for 100% load (inches). 4. S min = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. 8. fs = fsmin + [(1 - fsmin) (S act - S min) / (S cr - S min)].
21
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET
Epoxy Adhesives
Anchoring Adhesive
SET is a two-component, 1:1 ratio, high-solids, epoxy-based adhesive for use as a high strength, non-shrink anchor grouting material. Resin and hardener are dispensed and mixed simultaneously through the mixing nozzle. SET meets or exceeds the requirements of ASTM C-881 specication for Type I, II, IV and V, Grade 3, Class B and C. Uses: Threaded-rod anchoring Rebar doweling Bonding hardened concrete to hardened concrete Pick-proof sealant around doors, windows and xtures Paste-over for crack injection CoDes: ICC-ES ESR-1772 (CMU & URM); City of L.A. RR25279; Florida FL 11506.4; Caltrans approved; multiple DOT listings; NSF/ ANSI Standard 61 (216 in21000 gal), except SET1.7KTA. The load tables list values based upon results from the most recent testing and may not reect those in current code reports. Where code jurisdictions apply, consult the current reports for applicable load values. AppLication: Surfaces to receive epoxy must be clean. For installations in or through standing water, see page 225 for details. The base material temperature must be 40F or above at the time of installation. For best results, material should be 7080F at the time of application. Cartridges should not be immersed in water to facilitate warming. To warm cold material, the cartridges should be stored in a warm, uniformly heated area or storage container for a sufcient time to allow epoxy to warm completely. Mixed material in nozzle can harden in 57 minutes at a temperature of 40F or above. ASD DesiGn ExampLe: See page 231 InstaLLation: See pages 7071 SHeLF LiFe: 24 months from date of manufacture in unopened sideby-side cartridge. StoraGe ConDitions: For best results store between 45F 90F. To store partially used cartridges, leave hardened nozzle in place. To re-use, attach new nozzle. CoLor: Resin white, hardener black. When properly mixed SET adhesive will be a uniform light gray color. CLean Up: Uncured material Wipe up with cotton cloths. If desired scrub area with abrasive, waterbased cleaner and ush with water. If approved, solvents such as ketones (MEK, acetone, etc.), lacquer thinner or adhesive remover can be used. DO NOT USE SOLVENTS TO CLEAN ADHESIVE FROM SKIN. Take appropriate precautions when handling ammable solvents. Solvents may damage surfaces to which they are applied. Cured material Chip or grind off surface. Test Criteria: Anchors installed with SET adhesive have been tested in accordance with ICC-ES's Acceptance Criteria for Adhesive Anchors (AC58). In addition, anchors installed with SET adhesive have been tested in accordance with ICC-ES's Acceptance Criteria for Unreinforced Masonry Anchors (AC60). PropertY Test MetHoD ResuLts Consistency ASTM C 881 Non-sag/thixotropic paste Heat deection ASTM D 648 136F (58C) Bond strength (moist cure) ASTM C 882 3,218 psi (2 days) 3,366 psi (14 days) Water absorption ASTM D 570 0.110% (24 hours) Compressive yield strength ASTM D 695 5,065 psi (24 hours) 12,650 psi (7 days) Compressive modulus ASTM D 695 439,000 psi (7 days) Gel Time (75F) ASTM C 881 30 min. 60 gram mass 60 min Thin lm CHemicaL Resistance: Very good to excellent against distilled water, inorganic acids and alkalis. Fair to good against organic acids and alkalis, and many organic solvents. Poor against ketones. For more detailed information, visit www.strongtie.com.
SET1.7KTA
SET22
SET56
EMN22i
EDT22S
1. Bulk containers also available, call SimpsonStrongTie for details. 2. Cartridge and bulk estimation guides are available on pages 4851. 3. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available on pages 7277. 4. Use only appropriate SimpsonStrongTie mixing nozzle in accordance with SimpsonStrongTie instructions. Modification or improper use of mixing nozzle may impair epoxy performance.
SuGGesteD SpeciFications: Anchoring adhesive shall be a two-component high-solids epoxy based system supplied in manufacturer's standard cartridge and dispensed through a staticmixing nozzle supplied by the manufacturer. Epoxy shall meet the minimum requirements of ASTM C-881 specication for Type I, II, IV, and V, Grade 3, Class B and C and must develop a minimum 12,650 psi compressive yield strength after 7 day cure. Epoxy must have a heat deection temperature of a minimum 136F (58C). Adhesive shall be SET adhesive from SimpsonStrongTie, Pleasanton, CA. Anchors shall be installed per SimpsonStrongTie instructions for SET adhesive. Accessories: See pages 7277 for information on dispensing tools, mixing nozzles and other accessories.
IMPORTANT See Pages 7071 for Installation Instructions
22
Adaptor included EMN1.7 for standard (2 included) caulking tool EDT22S, EDTA22P EMN22i or EDTA22CKT EMN22i or EDTA56P EMN50
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET
Anchoring Adhesive
Cure Schedule
Base Material Temperature F 40 65 85 90 C 4 18 29 32 Cure Time (hrs.) 72 24 20 16
Epoxy Adhesives
(9.5)
2,105 (9.4)
4,535 (20.2)
3,630 (16.1)
(12.7)
3,750 (16.7)
8,080 (35.9)
6,470 (28.8)
(15.9)
5,875 (26.1)
12,660 (56.3)
10,120 (45.0)
(19.1)
8,460 (37.6)
18,230 (81.1)
12,400 (55.2)
23
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET
Epoxy Adhesives
Anchoring Adhesive
(22.2)
11,500 (51.2)
24,785 (110.2)
16,860 (75.0)
1 (25.4)
118
15,025 (66.8)
32,380 (144.0)
22,020 (97.9)
118 (28.6)
114
19,025 (84.6)
41,000 (182.4)
27,880 (124.0)
114 (31.8)
138
23,490 (104.5)
50,620 (225.2)
34,425 (153.1)
1. Allowable load must the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 31 and 33. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
6. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure and elevated-temperature conditions. 7. Allowable load based on bond strength may be interpolated for concrete compressive strengths between 2000 psi and 4000 psi.
24
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET
Anchoring Adhesive
Epoxy Adhesives
(9.5)
514 (133)
1,085 (4.8)
2,340 (10.4)
1,870 (8.3)
(12.7)
638 (162)
1,930 (8.6)
4,160 (18.5)
3,330 (14.8)
(15.9)
712 (191)
3,025 (13.5)
6,520 (29.0)
5,220 (23.2)
(19.1)
1018 (257)
4,360 (19.4)
9,390 (41.8)
6,385 (28.4)
(22.2)
1158 (295)
5,925 (26.4)
12,770 (56.8)
8,685 (38.6)
1 (25.4)
118
1312 (343)
7,740 (34.4)
16,680 (74.2)
11,345 (50.5)
118 (28.6)
114
1514 (387)
9,800 (43.6)
21,125 (94.0)
14,365 (63.9)
114 (31.8)
138
1678 (429)
12,100 (53.8)
26,075 (116.0)
17,730 (78.9)
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 32 and 34.
4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
25
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
Edge
134"
6"or 8"
W=
d En "
(15.9)
7
(22.2)
10 (254.0) 15 (381.0)
6 (152.4) 8 (203.2)
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature.
4. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
Edge and end distances for threaded rod in concrete foundation stemwall corner installation
Shear Loads for Threaded Rod Anchors in Normal-Weight Concrete, Load Applied Parallel to Concrete Edge
Rod Dia. Drill Bit in. Dia. (mm) in.
1
Shear Load Based on Concrete Edge Distance f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 8,496 654 2,125 (37.8) (2.9) (9.5) 8,857 225 2,215 (39.4) (1.0) (9.9)
(12.7)
5
8 4
(15.9)
26
1. Allowable load must be the lesser of the load based on concrete edge distance, steel strength or wood bearing capacity. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing on page 34.
4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fireexposure conditions.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET
Anchoring Adhesive
*
See page 13 for an explanation * of the load table icons
Epoxy Adhesives
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 31 and 33. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 6. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire exposure and elevatedtemperature conditions. 7. Allowable load based on bond strength may be interpolated for concrete compressive strengths between 2000 psi and 4000 psi.
*
See page 13 for an explanation * of the load table icons
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable loadadjustment factors for spacing and edge distance on pages 32 and 34. 4. Refer to in-service temperature Sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fireresistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
27
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
8 (9.5)
3
1 2 (12.7)
3,750 (16.7)
8,080 (35.9)
6,470 (28.8)
5 8 (15.9)
5,875 (26.1)
12,660 (56.3)
10,120 (45.0)
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. 100% of the allowable load is permitted at critical spacing. No reduction in spacing is allowed. 4. Refer to allowable load-adjustment factors for edge distance on page 35. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature.
6. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 7. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure and elevated-temperature conditions.
8 (9.5)
3
1 2 (12.7)
1,930 (8.6)
4,160 (18.5)
3,330 (14.8)
5 8 (15.9)
3,025 (13.5)
6,520 (29.0)
5,220 (23.2)
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. 100% of the allowable load is permitted at critical spacing. No reduction in spacing is allowed. 4. Refer to allowable load-adjustment factors for edge distance on page 35.
5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
28
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SET
Anchoring Adhesive
Tension and Shear Loads for Threaded Rod Anchors in 8-inch Lightweight, Medium-Weight and Normal-Weight Grout-Filled CMU
Rod Dia. in. (mm) Drill Bit Dia. in. Min. Embed. Depth in. (mm) Critical Edge Dist. in. (mm) Critical End Dist. in. (mm) Critical Spacing Dist. in. (mm) 8-inch Grout-Filled CMU Allowable Loads Based on CMU Strength
Epoxy Adhesives
(12.7)
5
8 4
(15.9)
3
8 4
3 7
(19.1)
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed Anywhere on the Face of the CMU Wall (See Figure 1) 414 17 17 17 6,496 1,300 6,766 1,355 (108) (432) (432) (432) (28.9) (5.8) (30.1) (6.0) 5 20 20 20 8,232 1,645 13,676 2,735 (127) (508) (508) (508) (36.6) (7.3) (60.8) (12.2) 634 27 27 27 15,656 3,130 17,578 3,515 (171) (686) (686) (686) (69.6) (13.9) (78.2) (15.6)
Figure 1
4" Minimum edge distance Critical edge distance (see load table) Installation in this area for reduced allowable load capacity
4" Minimum end distance Critical end distance (see load table)
1. Threaded rods must comply with ASTM F1554 Grade 36 5. Refer to in-service temperature sensitivity chart for minimum. allowable load adjustment for temperature. 2. Values for 8-inch wide concrete masonry units (CMU) with a 6. The tabulated allowable loads are based on a safety factor minimum specified compressive strength of masonry, f'm, at of 5.0 for installations under the IBC and IRC. 28 days is 1500 psi. 7. Refer to allowable load-adjustment factors for end 3. Embedment depth is measured from the outside face of the distance, edge distance and spacing on page 36. concrete masonry unit. 1 4. Allowable loads may be increased 33 3% for short-term loading due to wind forces or seismic forces where permitted by code.
Shaded Area = Placement for Full and Reduced Allowable Load Capacity in Grout-Filled CMU
Tension and Shear Loads for Threaded Rod Anchors in 6 and 8-inch Lightweight, Medium-Weight and Normal-Weight Grout-Filled CMU Anchor Installed in Cell Opening (Top of Wall) See Figure 2
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Depth in. (mm) Min. Edge Dist. in. (mm) Min. End Dist. in. (mm) Min. Spacing Dist. in. (mm)
Figure 2
Edge
5 8 (15.9) 3 4 (19.1)
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Allowable Tension and Shear Values EXCLUDING Earthquake Loads 1 5 3 312 20 12,573 2,515 9,530 1,905 (127) (76) (89) (508) (55.9) (11.2) (42.4) (8.5) 5 3 312 20 2,515 1,905 (127) (76) (89) (508) (11.2) (8.5) 12 2 378 48 8,908 1,780 (305) (51) (98) (1219) (39.6) (7.9) Allowable Tension and Shear Values INCLUDING Earthquake Loads 2 5 3 312 20 6,500 1,300 6,780 1,355 (127) (76) (89) (508) (28.9) (5.8) (30.2) (6.0) 5 3 312 20 1,300 1,355 (127) (76) (89) (508) (5.8) (6.0)
End
Tension and Shear Loads for Threaded Rod Anchors in Lightweight, Medium-Weight and Normal-Weight Hollow CMU
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Depth in. (mm) Min. Edge Dist. in. (mm) Min. End Dist. in. (mm)
Figure 3
5 8 (15.9) 3 4 (19.1)
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in Face Shell w/SimpsonStrongTie Epoxy Carbon-Steel Screen Tube 312 4 458 881 175 1,440 290 7 8 (88.9) (101.6) (117.5) (3.9) (0.8) (6.4) (1.3) 312 4 458 175 290 1 (88.9) (101.6) (117.5) (0.8) (1.3)
5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 7. Anchors must be spaced a minimum distance of four times the anchor embedment. 8. Screen tubes not for use with SET1.7KTA. 9. Set drill to rotation-only mode when drilling into hollow CMU.
4"
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. Values for 8-inch wide concrete masonry units (CMU) with a minimum specified compressive strength of masonry, f'm, at 28 days is 1500 psi. 3. Embedment depth is measured from the outside face of the concrete masonry unit for installations through a face shell. 4. Allowable loads may not be increased for short-term loading due to wind forces or seismic forces.
29
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
Tension and Shear Loads for Installations in Unreinforced Brick Masonry Walls Minimum URM Wall Thickness is 13" (3 wythes thick) *See page 13 for an explanation of the load table icons
Min. Min. Min. Tension Load Based Rod/Rebar Drill Embed. Edge/End Vertical Horiz. on URM Strength Dia./Size Bit Depth Dist. Spacing Spacing Minimum Net Mortar in. Dia. in. in. Dist. Dist. Strength = 50 psi (mm) in. (mm) (mm) in. in. Allowable lbs. (kN) (mm) (mm) 4 (19.1) #5 (15.9) #6 (19.1)
3 3 4 (19.1)
*
Conguration A (Shear)
Shear Load Based on URM Strength Minimum Net Mortar Strength = 50 psi Allowable lbs. (kN)
SCREEN TUBE
5 8 (15.9)
Conguration A (SimpsonStrongTie ETS or ETSP Screen Tube Required) 8 16 16 16 1,000 1 (203) (406) (406) (406) (4.4) 8 16 16 16 750 1 (203) (406) (406) (406) (3.3) 8 16 16 16 1,000 1 (203) (406) (406) (406) (4.4) Conguration B (SimpsonStrongTie ETS or ETSP Screen Tube Required) 13 16 16 16 1,200 1,000 1 (330) (406) (406) (406) (5.3) (4.4) Conguration C (SimpsonStrongTie ETS Screen Tube and AST Steel Sleeve Required) 16 16 16 1,200 750 1 ** (406) (406) (406) (5.3) (3.3)
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. All holes are drilled with a 1" diameter carbide-tipped drill bit with the drill set in the rotation-only mode. 3. The unreinforced brick walls must have a minimum thickness of 13 inches (three wythes of brick). 4. The allowable load is applicable only where in-place shear tests indicate minimum net mortar strength of 50 psi. 5. The allowable load for Configuration B and C anchors subjected to a combined tension and shear load is determined by assuming a straight-line relationship between allowable tension and shear. 6. The anchors installed in unreinforced brick walls are limited to resisting seismic or wind forces only. 7. Configuration A has a straight threaded rod or rebar embedded 8 inches into the wall with a 3132" diameter by 8-inch long screen tube (part # ETS758 or ETS758P). This configuration is designed to resist shear loads only. 8. Configuration B has a 34" threaded rod bent and installed at a 22.5-degree angle and installed 13 inches into the wall, to within 1-inch (maximum) of the exterior wall surface. This configuration is designed to resist tension and shear loads. The pre-bent threaded rod is installed with a 3132" diameter by 13-inch long screen tube (part # ETS7513 or ETS7513P). 9. Configuration C is designed to resist tension and shear forces. It consists of a 58" diameter, ASTM F1554 Grade 36 threaded rod and an 8" long sleeve (part # AST800) and a 3132" diameter by 8-inch long screen tube (part # ETS758). The steel sleeve has a plastic plug in one end. A 6" by 6" by 38" thick ASTM A 36 steel plate is located on the back face of the wall. 10. Special inspection requirements are determined by local jurisdiction and must be confirmed by the local building official. 11. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 12. Screen tubes not for use with SET1.7KTA.
SCREEN TUBE
Tension and Shear Loads for Threaded Rod Anchors in Lightweight, Medium-Weight and Normal-Weight Hollow CMU
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Depth in. (mm) Critical Edge Dist. in. (mm) Critical Spacing Dist. in. (mm)
*
*See page 13 for an explanation of the load table icons
HEX NUT
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in Face Shell w/Simpson Strong-Tie ETSP (Plastic) Screen Tube 3 12 8 1,500 300 1,280 255 9 16 (76.2) (305) (203) (6.7) (1.3) (5.7) (1.1) 3 12 8 1,500 300 1,280 255 3 4 (76.2) (305) (203) (6.7) (1.3) (5.7) (1.1) 3 12 8 1,500 300 1,380 275 7 8 (76.2) (305) (203) (6.7) (1.3) (6.1) (1.2)
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 3. Edge distances may be reduced to 4" with a corresponding 32% reduction in tension capacity. Shear capacity is unaffected. 4. Values for 8-inch wide, lightweight, medium-weight and normal-weight concrete masonry units with min. compressive strength of 1,900 psi and 114" thick face shell. 5. Embedment depth is measured from the outside face of the concrete masonry unit. 6. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 7. Allowable loads may not be increased for short-term loading due to wind or seismic forces. Wall design must satisfy applicable design standards and be capable of withstanding applied loads. 8. Screen tubes not for use with SET1.7KTA. 9. Set drill to rotation-only mode when drilling into hollow CMU.
Installation Instructions for Conguration C: 1. Drill hole perpendicular to the wall to a depth of 8" with a 1" diameter carbidetipped drill bit (rotation only mode). 2. Clean hole with oil-free compressed air and a nylon brush. 3. Fill 8" steel screen tube with mixed adhesive and insert into hole. 4. Insert steel sleeve slowly into screen tube (adhesive will displace). 5. Allow adhesive to cure (see cure schedule). 6. Drill through plastic plug in (inside) end of steel sleeve with 58" bit. 7. Drill completely through the wall with 5 8" carbide tipped concrete drill bit (rotation mode only). 8. Insert 58" rod through hole and attach metal plate and nut.
30
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8
412 634 134 0.69 0.69 0.71 0.77 0.83 0.89 0.95 1.00 218 314 134 0.65 0.65 0.71 0.95 1.00
#4 6 9 134 0.59 0.59 0.60 0.66 0.72 0.77 0.83 0.89 0.94 1.00 212 334 134 0.48 0.48 0.55 0.81 1.00
#5 938 1418 134 0.64 0.64 0.65 0.68 0.71 0.73 0.76 0.79 0.82 0.85 0.88 0.91 0.94 1.00 338 518 134 0.48 0.48 0.52 0.68 0.83 0.99 1.00
#6 1114 1678 134 0.57 0.57 0.58 0.61 0.63 0.66 0.69 0.72 0.75 0.78 0.80 0.83 0.86 0.92 0.98 1.00
312 514 134 0.65 0.65 0.68 0.78 0.88 0.98 1.00
414 638 134 0.65 0.65 0.67 0.74 0.82 0.90 0.97 1.00
5 712 134 0.48 0.48 0.50 0.59 0.68 0.77 0.86 0.95 1.00
634 1018 134 0.48 0.48 0.50 0.56 0.62 0.68 0.74 0.81 0.87 0.93 0.99 1.00
1 #7 1318 1958 134 0.52 0.52 0.55 0.58 0.63 0.69 0.74 0.80 0.85 0.90 0.96 1.00 412 634 134 0.48 0.48 0.58 0.71 0.92 1.00 9 1312 134 0.48 0.48 0.52 0.58 0.67 0.76 0.85 0.93 1.00 #8 15 2212 134 0.47 0.47 0.50 0.53 0.58 0.63 0.68 0.73 0.78 0.83 0.89 0.94 1.00 518 734 234 0.58 0.58 0.69 0.85 1.00
118 #9 1018 1514 234 0.58 0.58 0.62 0.69 0.76 0.82 0.89 0.96 1.00 1678 2538 234 0.51 0.51 0.54 0.58 0.62 0.67 0.71 0.75 0.80 0.84 0.88 0.97 1.00 558 812 234 0.58 0.58 0.67 0.82 0.97 1.00
114 #10 1114 1834 7 16 8 2818 234 234 0.58 0.51 0.58 0.62 0.68 0.74 0.80 0.86 0.91 0.97 1.00 0.51 0.53 0.57 0.61 0.65 0.69 0.73 0.77 0.80 0.84 0.92 1.00 #11 1238 2058 2818 2818 234 234 0.58 0.51 0.58 0.61 0.67 0.72 0.77 0.82 0.88 0.93 0.98 1.00 0.51 0.53 0.57 0.61 0.65 0.69 0.73 0.77 0.81 0.84 0.92 1.00
734 1158 134 0.48 0.48 0.53 0.60 0.70 0.81 0.91 1.00
1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. C cr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches).
5. fc = adjustment factor for allowable load at actual edge distance. 6. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (C act - Cmin) / (C cr - Cmin)].
31
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 412 514 134 0.35 0.35 0.40 0.58 0.77 0.95 1.00 218 638 134 0.37 0.37 0.40 0.54 0.68 0.81 0.95 1.00
2 #4 414 638 134 0.20 0.20 0.24 0.42 0.59 0.76 0.94 1.00 414 638 134 0.25 0.25 0.29 0.45 0.61 0.78 0.94 1.00
2 212 712 134 0.18 0.18 0.22 0.36 0.50 0.64 0.79 0.93 1.00
8 #5 5 712 134 0.15 0.15 0.19 0.33 0.48 0.63 0.78 0.93 1.00 5 712 134 0.21 0.21 0.24 0.38 0.52 0.66 0.79 0.93 1.00
8 338 1018 134 0.16 0.16 0.19 0.29 0.39 0.49 0.59 0.69 0.79 0.89 0.99 1.00
4 #6 634 1018 134 0.16 0.16 0.19 0.29 0.39 0.49 0.59 0.69 0.79 0.89 0.99 1.00 634 1018 134 0.18 0.18 0.20 0.30 0.40 0.50 0.60 0.69 0.79 0.89 0.99 1.00
134 514 134 0.49 0.49 0.53 0.67 0.82 0.96 1.00
312 514 134 0.32 0.32 0.37 0.56 0.76 0.95 1.00
6 638 134 0.24 0.24 0.28 0.45 0.61 0.77 0.94 1.00
938 712 134 0.19 0.19 0.23 0.37 0.51 0.65 0.79 0.93 1.00
1114 1018 134 0.15 0.15 0.18 0.28 0.38 0.48 0.58 0.68 0.78 0.89 0.99 1.00
#7 378 1158 134 0.14 0.14 0.23 0.25 0.34 0.42 0.51 0.60 0.68 0.77 0.86 0.95 1.00 734 1158 134 0.13 0.13 0.22 0.24 0.33 0.42 0.50 0.59 0.68 0.77 0.86 0.94 1.00 734 1158 134 0.14 0.14 0.23 0.25 0.34 0.42 0.51 0.60 0.68 0.77 0.86 0.95 1.00 1318 1158 134 0.10 0.10 0.19 0.21 0.31 0.40 0.49 0.58 0.67 0.76 0.85 0.94 1.00 412 1312 134 0.14 0.14 0.21 0.23 0.30 0.38 0.45 0.52 0.60 0.67 0.74 0.82 0.89 0.96 1.00 9 1312 134 0.10 0.10 0.18 0.20 0.27 0.35 0.43 0.50 0.58 0.66 0.73 0.81 0.89 0.96 1.00 9 1312 134 0.12 0.12 0.19 0.21 0.29 0.36 0.44 0.51 0.59 0.66 0.74 0.81 0.89 0.96 1.00
#8 15 1312 134 0.10 0.10 0.18 0.20 0.27 0.35 0.43 0.50 0.58 0.66 0.73 0.81 0.89 0.96 1.00 518 1514 234 0.17 0.17 0.19 0.25 0.32 0.39 0.45 0.52 0.59 0.65 0.72 0.78 0.85 0.92 0.98 1.00 1018 1514 234 0.16 0.16 0.18 0.24 0.31 0.38 0.45 0.51 0.58 0.65 0.71 0.78 0.85 0.92 0.98 1.00
#9 1678 1514 234 0.12 0.12 0.14 0.21 0.28 0.35 0.42 0.49 0.56 0.63 0.70 0.77 0.84 0.91 0.98 1.00 558 1678 234 0.17 0.17 0.18 0.24 0.30 0.36 0.42 0.48 0.54 0.60 0.65 0.71 0.77 0.83 0.89 0.95 1.00
#10 1114 1834 7 16 8 1678 234 234 0.16 0.12 0.16 0.17 0.23 0.29 0.35 0.41 0.47 0.53 0.59 0.65 0.71 0.77 0.83 0.89 0.95 1.00 0.12 0.14 0.20 0.26 0.32 0.38 0.45 0.51 0.57 0.63 0.70 0.76 0.82 0.88 0.95 1.00
#11 1238 2058 1858 1858 234 234 0.16 0.12 0.16 0.17 0.23 0.28 0.33 0.38 0.44 0.49 0.54 0.60 0.65 0.70 0.76 0.81 0.86 0.91 1.00 0.12 0.13 0.19 0.24 0.30 0.36 0.41 0.47 0.52 0.58 0.63 0.69 0.74 0.80 0.85 0.91 1.00
32
1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. Ccr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches).
5. fc = adjustment factor for allowable load at actual edge distance. 6. fccr = adjustment factor for allowable load at critical edge distance. f ccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
118
114
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple spacings are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable tension load based on bond strength values only.
8 1 2 4 6 8 10 12 14 16 18 20 24 28 32 36 40 45
7
5 20 212 0.89
0.90 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.98 1.00
0.90 0.91 0.92 0.92 0.93 0.93 0.94 0.95 0.96 0.97 0.98 1.00 1.00
0.89 0.90 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.99 1.00
0.90 0.91 0.91 0.92 0.92 0.93 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00
1. E = Embedment depth (inches). 2. S act = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. f s = adjustment factor for allowable load at actual spacing distance. 6. f scr = adjustment factor for allowable load at critical spacing distance. f scr is always = 1.00. 7. f smin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
8 #7 1318 5212 658 0.90 412 18 214 0.52 0.54 0.57 0.60 0.63 0.70 0.76 0.82 0.88 0.94 1.00
1 #8 9 36 412 0.89 15 60 712 0.90 518 2012 258 0.52 0.53 0.56 0.58 0.61 0.66 0.72 0.77 0.83 0.88 0.99 1.00
118 #9 1018 4012 518 0.89 1678 6712 812 0.90 558 2212 278 0.52 0.52 0.55 0.57 0.60 0.65 0.69 0.74 0.79 0.84 0.94 1.00
114 #10 1114 1834 45 75 558 938 0.89 0.90 #11 1238 2058 4912 8212 614 1038 0.89 0.90
See page 13 for * an explanation of the load table icons
2 3 4 5 6 8 10 12 14 16 20 24 28 32 36 40 50 60 70 75 8212
378 1512 2 0.52 0.52 0.56 0.59 0.63 0.66 0.73 0.80 0.88 0.95 1.00
0.89 0.89 0.90 0.91 0.91 0.92 0.93 0.94 0.96 0.97 0.99 1.00
0.90 0.91 0.91 0.92 0.92 0.93 0.94 0.95 0.96 0.96 0.97 0.99 1.00
0.89 0.90 0.90 0.91 0.92 0.92 0.93 0.94 0.96 0.97 0.99 1.00
0.90 0.90 0.91 0.91 0.92 0.92 0.93 0.94 0.95 0.95 0.96 0.98 1.00
0.89 0.90 0.91 0.91 0.92 0.92 0.94 0.95 0.96 0.97 0.99 1.00
0.90 0.91 0.91 0.91 0.92 0.93 0.93 0.94 0.95 0.95 0.97 0.99 1.00
0.89 0.90 0.90 0.91 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.99 1.00
0.90 0.90 0.91 0.91 0.92 0.92 0.93 0.93 0.94 0.95 0.96 0.98 0.99 1.00
0.89 0.90 0.90 0.91 0.91 0.92 0.94 0.95 0.96 0.97 0.98 1.00
0.90 0.91 0.91 0.91 0.92 0.92 0.93 0.94 0.94 0.95 0.97 0.98 0.99 1.00 33
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple spacings are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable shear load based on concrete edge distance values only.
ee page 13 for * * S an explanation of
8
312 514 134 0.83 218 314 118 0.90
Sact (in.)
134 258
7
1. E = Embedment depth (inches). 2. S act = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. f s = adjustment factor for allowable load at actual spacing distance. 6. f scr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. f smin = adjustment factor for allowable load at minimum spacing distance. 8. f s = f smin + [(1 - f smin) (S act - Smin) / (Scr - Smin)].
34
1 #7 734 1158 378 0.83 412 634 214 0.90 #8 9 1312 412 0.83 518 734 258 0.90
114 #10 1114 1678 558 0.83 #11 1238 1858 614 0.83
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
312 514 134 0.65 0.65 0.68 0.70 0.73 0.75 0.78 0.80 0.83 0.85 0.88 0.90 0.93 0.95 0.98 1.00
218 318 134 0.65 0.65 0.71 0.78 0.84 0.90 0.97 1.00
414 638 134 0.65 0.65 0.67 0.69 0.71 0.73 0.74 0.76 0.78 0.80 0.82 0.84 0.86 0.88 0.90 0.91 0.93 0.95 0.97 0.99 1.00
212 334 134 0.48 0.48 0.55 0.61 0.68 0.74 0.81 0.87 0.94 1.00
5 712 134 0.48 0.48 0.50 0.53 0.55 0.57 0.59 0.62 0.64 0.66 0.68 0.71 0.73 0.75 0.77 0.80 0.82 0.84 0.86 0.89 0.91 0.93 0.95 0.98 1.00
312 514 134 0.25 0.25 0.30 0.36 0.41 0.46 0.52 0.57 0.63 0.68 0.73 0.79 0.84 0.89 0.95 1.00
218 318 134 0.20 0.20 0.35 0.49 0.64 0.78 0.93 1.00
414 638 134 0.20 0.20 0.24 0.29 0.33 0.37 0.42 0.46 0.50 0.55 0.59 0.63 0.68 0.72 0.76 0.81 0.85 0.89 0.94 0.98 1.00
212 334 134 0.15 0.15 0.26 0.36 0.47 0.58 0.68 0.79 0.89 1.00
5 712 134 0.15 0.15 0.19 0.22 0.26 0.30 0.33 0.37 0.41 0.45 0.48 0.52 0.56 0.59 0.63 0.67 0.70 0.74 0.78 0.82 0.85 0.89 0.93 0.96 1.00
1. E = Embedment depth (inches). 2. C act = actual edge distance at which anchor is installed (inches). 3. C cr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual edge distance. 6. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (C act - Cmin) / (C cr - Cmin)].
35
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
634 27 4 0.54** 0.54 0.62 0.70 0.78 0.80 0.86 0.94 1.00
634 27 4 0.54** 0.54 0.62 0.70 0.78 0.80 0.86 0.94 1.00
**The allowable tension load reduction factor is permitted to equal 1.0 provided both of the following conditions are met: (a) The anchor is installed with a minimum end distance, Cmin, between 4 inches and 8 inches; and (b) a masonry return wall of identical construction is on the opposite side (such as two masonry walls intersecting at a building corner).
End and Edge Distance Shear (fc) Shear Load Perpendicular to End or Edge
Cact (in.) 4 8 12 16 17 20 24 27 Dia. E Ccr Cmin fcmin
1
*
3
End and Edge Distance Shear (fc) Shear Load Parallel to End or Edge
Cact (in.) 4 8 12 16 17 20 24 27 Dia. E Ccr Cmin fcmin
1
*
5
* 2
5
*
414 17 8 1.00
36
5 20 8 1.00
634 27 8 1.00
1. E = Embedment depth (inches). 2. S act = actual spacing distance at which anchors are installed (inches). 3. S cr = critical spacing distance for 100% load (inches). 4. S min = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. 8. fs = fsmin + [(1 - fsmin) (S act - S min) / (S cr - S min)].
634 27 4 0.45 0.45 0.55 0.64 0.74 0.76 0.83 0.93 1.00
1. E = Embedment depth (inches). 2. C act = actual end or edge distance at which anchor is installed (inches). 3. C cr = critical end or edge distance for 100% load (inches). 4. Cmin = minimum end or edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual end or edge distance. 6. fccr = adjustment factor for allowable load at critical end or edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum end or edge distance. 8. fc = fcmin + [(1 - fcmin) (C act - Cmin) / (C cr - Cmin)].
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
ET-HP22
ET-HP56
EMN22i
EDT22S
1. Cartridge and bulk estimation guides are available on pages 4851. 2. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available on pages 7277. 3. Use only appropriate SimpsonStrongTie mixing nozzle in accordance with SimpsonStrongTie instructions. Modification or improper use of mixing nozzle may impair epoxy performance.
SUGGESTED SPECIFICATIONS: Anchoring adhesive shall be a two-component high solids epoxy based system supplied in manufacturer's standard side-by-side cartridge and dispensed through a static-mixing nozzle supplied by the manufacturer. Epoxy shall meet the minimum requirements of ASTM C-881 specication for Type I, II, IV, and V, Grade 3, Class B and C, except gel time, and must develop a minimum 13,390 psi compressive yield strength after 7 day cure. Epoxy must have a heat deection temperature of a minimum 168F (76C). Adhesive shall be ET-HP adhesive from SimpsonStrongTie, Pleasanton, CA. Anchors shall be installed per SimpsonStrongTie instructions for ET-HP adhesive. Accessories: See pages 7277 for information on dispensing tools, mixing nozzles and other accessories.
IMPORTANT See Pages 7071 for Installation Instructions 37
CHEMICAL RESISTANCE Very good to excellent against distilled water, inorganic acids and alkalis. Fair to good against organic acids and alkalis, and many organic solvents. Poor against ketones. For more detailed information, visit www.strongtie.com.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
ET-HP Epoxy Anchor Installation Information and Additional Data for Threaded Rod and Rebar in Normal-Weight Concrete1
Characteristic Drill Bit Diameter Maximum Tightening Torque Permitted Embedment Depth Range2 Minimum Concrete Thickness Critical Edge Distance Minimum Edge Distance Minimum Anchor Spacing Minimum Maximum Symbol dhole Tinst hef hef hmin cac cmin smin 8 / #3 Installation Information 1 in. 2 ft-lb 10 in. 238 in. 412 in. in. in. in.
3
Units
Nominal Anchor Diameter (in.) / Rebar Size 12 / #4 58 / #5 34 / #6 78 / #7 1 / #8 58 20 234 6 34 30 318 712 78 45 312 9 hef + 5do 2.75 x hef 134 3 1 60 334 1012 118 80 4 12
234 6
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308. 2. Minimum and maximum embedment depths are are listed in accordance with ICC-ES AC308 requirements.
38
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
Characteristic
0.606 0.969 75,750 121,125 35,150 56,200 66,660 106,590 34,540 55,235
1,330 365
1,225 335
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modified below. 2. Temperature Range 1: Maximum short-term temperature of 110F (43C). Maximum long-term temperature of 75F (24C). 3. Temperature Range 2: Maximum short-term temperature of 150F (66C). Maximum long-term temperature of 110F (43C). 4. Short-term concrete temperatures are those that occur over short intervals (diurnal cycling). 5. Long-term concrete temperature are constant temperatures over a significant time period. 6. For anchors that only resist wind or seismic loads, bond strengths may be multiplied by 2.25. 7. For anchors installed in overhead and subjected to tension resulting from sustained loading, multiply the value calculated for Na according to ICC-ES AC308 by 0.75. 8. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of .
9. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 10. T he value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition A are met, refer to Section D.4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 11. Sand-lightweight and all-lightweight concrete are beyond the scope of this table.
39
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 / #5 / #6
8 / #7 1 / #8 1 / #10
Ase Vsa
in
2
do
e
kcp
1. The information presented in this table is to be used in conjunction with the design criteria of ICC-ES AC308, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 3. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition A are met, refer to Section D.4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 4. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 5. Sand-lightweight and all-lightweight concrete are beyond the scope of this table.
Embed. Depth in. (mm) 312 (89) 414 (108) 5 (127) 634 (171) 734 (197) 9 (229) 1018 (257) 1114 (286)
Critical Edge Dist. in. (mm) 514 (133) 638 (162) 712 (191) 1018 (257) 1158 (295) 1312 (343) 1514 (387) 1678 (429)
Critical Spacing Dist. in. (mm) 14 (356) 17 (432) 20 (508) 27 (686) 31 (787) 36 (914) 4012 (1029) 45 (1143)
Tension Load Based on Bond Strength f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 8,777 324 2,195 (39.0) (1.4) (9.8) 15,368 605 3,840 (68.4) (2.7) (17.1) 22,877 718 5,720 (101.8) (3.2) (25.4) 35,459 4,940 8,865 (157.7) (22.0) (39.4) 43,596 1,130 10,900 (193.9) (5.0) (48.5) 47,333 1,243 11,835 (210.5) (5.5) (52.6) 61,840 15,460 (275.1) (68.8) 78,748 4,738 19,685 (350.3) (21.1) (87.6)
Tension Load Based on Steel Strength F1554 Grade 36 Allowable lbs. (kN) 2,105 (9.4) 3,750 (16.7) 5,875 (26.1) 8,460 (37.6) 11,500 (51.2) 15,025 (66.8) 19,025 (84.6) 23,490 (104.5) A193 GR B7 Allowable lbs. (kN) 4,535 (20.2) 8,080 (35.9) 12,660 (56.3) 18,230 (81.1) 24,785 (110.2) 32,380 (144.0) 41,000 (182.4) 50,620 (225.2) F593 304SS Allowable lbs. (kN) 3,630 (16.1) 6,470 (28.8) 10,120 (45.0) 12,400 (55.2) 16,860 (75.0) 22,020 (97.9) 27,880 (124.0) 34,420 (153.1)
(9.5) (12.7)
5
8 4
(15.9)
3 7
8 4
3 7
40
1. Allowable load must the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 44 and 45. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature.
5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 6. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fireexposure and elevated-temperature conditions.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Shear Load Based on Steel Strength F1554 Grade 36 Allowable lbs. (kN) 1,085 (4.8) 1,930 (8.6) 3,025 (13.5) 4,360 (19.4) 5,925 (26.4) 7,740 (34.4) 9,800 (43.6) 12,100 (53.8) A193 GR B7 Allowable lbs. (kN) 2,340 (10.4) 4,160 (18.5) 6,520 (29.0) 9,390 (41.8) 12,770 (56.8) 16,680 (74.2) 21,125 (94.0) 26,075 (116.0) F593 304SS Allowable lbs. (kN) 1,870 (8.3) 3,330 (14.8) 5,220 (23.2) 6,385 (28.4) 8,685 (38.6) 11,345 (50.5) 14,365 (63.9) 17,730 (78.9)
Embed. Depth in. (mm) 312 (89) 414 (108) 5 (127) 634 (171) 734 (197) 9 (229) 1018 (257) 1114 (286)
Critical Edge Dist. in. (mm) 514 (133) 638 (162) 712 (191) 1018 (257) 1158 (295) 1312 (343) 1514 (387) 1678 (429)
Critical Spacing Dist. in. (mm) 514 (133) 638 (162) 712 (191) 1018 (257) 1158 (295) 1312 (343) 1514 (387) 1678 (429)
Shear Load Based on Concrete Edge Distance f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 7,615 591 1,905 (33.9) (2.6) (8.5) 11,273 1,502 2,820 (50.1) (6.7) (12.5) 19,559 1,289 4,890 (87.0) (5.7) (21.8) 27,696 2,263 6,925 (123.2) (10.1) (30.8) 6,925 (30.8) 53,960 3,821 13,490 (240.0) (17.0) (60.0) 59,280 14,820 (263.7) (65.9) 64,572 3,503 16,145 (287.2) (15.6) (71.8)
Epoxy Adhesives
(9.5) (12.7)
5
8 4
(15.9)
3 7
8 4
3 7
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 45 and 46. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
(15.9) (15.9)
7 7
8 8
3 3
4 4
(22.2) (22.2)
8 8
1 1
Tension Load Based on Tension Load Based on Min. Steel Strength Bond Strength End f' 2000 psi F1554 c Dist. (13.8 MPa) Concrete Grade 36 in. Allowable (mm) Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 5 10,720 1,559 2,680 5,875 (127.0) (47.7) (6.9) (11.9) (26.1) 5 16,150 260 4,040 5,875 (127.0) (71.8) (1.2) (18.0) (26.1) 5 17,000 303 4,250 11,500 (127.0) (75.6) (1.3) (18.9) (51.2) 5 23,340 762 5,835 11,500 (127.0) (103.8) (3.4) (26.0) (51.2)
134"
6"or 8"
W=
d En "
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 4. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
Edge and end distances for threaded rod in concrete foundation stemwall corner installation
41
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Tension Load Based on Steel Strength ASTM A615 Grade 60 Rebar Allowable lbs. (kN) 4,800 (21.4)
#4 (12.7)
#5 (15.9)
7,440 (33.1)
#6 (19.1)
10,560 (47.0)
#7 (22.2)
14,400 (64.1)
#8 (25.4)
118
18,960 (84.3)
#9 (28.6)
114
24,000 (106.8)
#11 (34.9)
158
37,440 (166.5)
#14 (44.5)
54,000 (240.2)
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 45 and 46. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 6. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure and elevated-temperature conditions.
42
#10 (31.8)
112
30,480 (135.6)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
8 4
3 7
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 45 and 46. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
1" MIN. (TYP.)
Tension and Shear Loads for Threaded Rod Anchors in 6 and 8-inch Normal-Weight Grout-Filled CMU
Rod Drill Embed. Dia. Bit Depth 8 in. Dia. in. (mm) in. (mm) Min. Edge Dist. in. (mm) Min. End Dist. in. (mm) Min. Spacing Dist. in. (mm) 6 and 8-inch Grout-Filled CMU Allowable Loads Based on CMU Strength
EDGE DISTANCE
Figure 1
END DISTANCE
(9.5)
16
(12.7)
16
(15.9)
(19.1)
3 1
(9.5) (12.7)
5
7 9
16 16 4
(15.9)
3
8 4
3 7
(19.1)
5
8 4
(15.9)
3
8 4
3 7
(19.1)
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in Face Shell (See Figure 1) 12 4 14 6,489 1,300 5,231 1,045 (305) (102) (356) (28.9) (5.8) (23.3) (4.6) 312 (89) 12 12 14 7,247 1,450 6,738 1,350 (305) (305) (356) (32.2) (6.4) (30.0) (6.0) 12 4 17 8,646 1,730 5,705 1,140 (305) (102) (432) (38.5) (7.7) (25.4) (5.1) 414 (108) 12 12 17 8,975 1,795 10,879 2,175 (305) (305) (432) (39.9) (8.0) (48.4) (9.7) 12 4 19 10,213 2,045 5,973 1,195 (305) (102) (483) (45.4) (9.1) (26.6) (5.3) 434 (121) 12 12 19 11,290 2,260 13,027 2,605 (305) (305) (483) (50.2) (10.1) (57.9) (11.6) 6 4 458 24 4,905 980 4,766 955 (152) (102) (117) (610) (21.8) (4.4) (21.2) (4.2) 12 4 27 11,976 2,395 (305) (102) (686) (53.3) (10.7) 634 (171) 12 12 27 19,141 3,830 (305) (305) (686) (85.1) (17.0) Anchor Installed in Mortar T Joint (See Figure 2) 312 8 8 14 7,646 1,530 5,507 1,100 (89) (203) (203) (356) (34.0) (6.8) (24.5) (4.9) 414 8 8 17 9,529 1,905 8,003 1,600 (108) (203) (203) (432) (42.4) (8.5) (35.6) (7.1) 434 8 8 19 9,955 1,990 9,529 1,905 (121) (203) (203) (483) (44.3) (8.9) (42.4) (8.5) 634 16 8 27 7,238 1,450 (171) (406) (203) (686) (32.2) (6.4) Anchor Installed in Cell Opening (Top of Wall) (See Figure 3) 6 4 458 24 6,721 1,345 4,833 965 (152) (102) (117) (610) (29.9) (6.0) (21.5) (4.3) 6 4 458 24 1,345 965 (152) (102) (117) (610) (6.0) (4.3)
Figure 2
END DISTANCE
Figure 3
End
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. Values for 6- and 8-inch wide concrete masonry units (CMU) with a minimum specified compressive strength of masonry, f'm, at 28 days is 1500 psi. 3. Embedment depth is measured from the outside face of the concrete masonry unit for installations through a face shell. 4. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 7. Anchors must be spaced a minimum distance of four times the anchor embedment. 8. For embedment depths of 6", 8-inch-wide normal-weight grout-filled CMU block must be used.
43
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Figure 1
458"
(12.7)
3
2 4
11
16
(19.1)
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in Face Shell w/ETS Screen Tube (See Figure 1) 3 4 458 1,400 280 1,326 265 (76.2) (101.6) (117.5) (6.2) (1.2) (5.9) (1.2) 280 265 3 4 458 (117.5) (1.2) (1.2) (76.2) (101.6)
4"
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. Values for 6- and 8-inch wide concrete masonry units (CMU) with a minimum specified compressive strength of masonry, f'm, at 28 days is 1500 psi. 3. Embedment depth is measured from the outside face of the concrete masonry unit for installations through a face shell. 4. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 7. Anchors must be spaced a minimum distance of four times the anchor embedment. 8. Set drill to rotation-only mode when drilling into hollow CMU.
Conguration A (Shear)
SCREEN TUBE
Tension and Shear Loads for Installations in Unreinforced Brick Masonry Walls Minimum URM Wall Thickness is 13" (3 wythes thick)
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Min. Depth Edge/End in. Dist. (mm) in. (mm) Min. Vertical Spacing Dist. in. (mm) Min. Horiz. Spacing Dist. in. (mm) Tension Load Based on URM Strength Minimum Net Mortar Strength = 50 psi Allowable lbs. (kN) Shear Load Based on URM Strength Minimum Net Mortar Strength = 50 psi Allowable lbs. (kN) 1,000 (4.4) 1,000 (4.4) 750 (3.3)
SCREEN TUBE
(19.1)
3
(19.1)
5
(15.9)
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. All holes are drilled with a 1" diameter carbide-tipped drill bit with the drill set in the rotation-only mode. 3. The unreinforced brick walls must have a minimum thickness of 13 inches (three wythes of brick). 4. The allowable load is applicable only where in-place shear tests indicate minimum net mortar strength of 50 psi. 5. The allowable load for Configuration B and C anchors subjected to a combined tension and shear load is determined by assuming a straight-line relationship between allowable tension and shear. 6. The anchors installed in unreinforced brick walls are limited to resisting seismic or wind forces only. 7. Configuration A has a straight threaded rod or rebar embedded 8 inches into the wall with a 3132" diameter by 8-inch long screen tube (part # ETS758 or ETS758P). This configuration is designed to resist shear loads only.
8. Configuration B has a " threaded rod bent and installed at a 22.5-degree angle and installed 13 inches into the wall, to within 1-inch (maximum) of the exterior wall surface. This configuration is designed to resist tension and shear loads. The pre-bent threaded rod is installed with a 3132" diameter by 13-inch long screen tube (part # ETS7513 or ETS7513P). 9. Configuration C is designed to resist tension and shear forces. It consists of a 58" diameter, ASTM F1554 Grade 36 threaded rod and an 8" long sleeve (part # AST800) and a 3132" diameter by 8-inch long screen tube (part # ETS758). The steel sleeve has a plastic plug in one end. A 6" by 6" by 38" thick ASTM A 36 steel plate is located on the back face of the wall. 10. Special inspection requirements are determined by local jurisdiction and must be confirmed by the local building official. 11. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature.
HEX NUT
44
1. Drill hole perpendicular to the wall to a depth of 8" with a 1" diameter carbidetipped drill bit (rotation only mode). 2. Clean hole with oil-free compressed air and a nylon brush. 3. Fill 8" steel screen tube with mixed adhesive and insert into hole. 4. Insert steel sleeve slowly into screen tube (adhesive will displace). 5. Allow adhesive to cure (see cure schedule). 6. Drill through plastic plug in (inside) end of steel sleeve with 58" bit. 7. Drill completely through the wall with 5 8" carbide tipped concrete drill bit (rotation mode only). 8. Insert 58" rod through hole and attach metal plate and nut.
Conguration A (Simpson ETS or ETSP Screen Tube Required) 8 24 18 18 (203) (610) (457) (457) Conguration B (Simpson ETS or ETSP Screen Tube Required) 13 16 18 24 1,200 (330) (406) (457) (610) (5.3) Conguration C (Simpson ETS Screen Tube and AST Steel Sleeve Required) 24 18 18 1,200 ** (610) (457) (457) (5.3)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
#4
#5
#6
1 #7 #8
118
114
E
Ccr Cmin fcmin
312
514 134
414
638 134
6
9 134
5
712 134
938 0.64 0.64 0.67 0.68 0.71 0.73 0.76 0.79 0.82 0.85 0.88 0.94 1.00
634 1114 734 1318 0.50 0.50 0.56 0.57 0.63 0.69 0.75 0.81 0.87 0.93 0.99 1.00 0.57 0.57 0.60 0.61 0.63 0.66 0.69 0.72 0.75 0.78 0.80 0.86 0.92 0.98 1.00 0.50 0.50 0.55 0.56 0.61 0.66 0.72 0.77 0.82 0.87 0.92 1.00 0.52 0.52 0.55 0.55 0.58 0.61 0.63 0.66 0.69 0.71 0.74 0.79 0.85 0.90 0.95 1.00
9 0.50 0.50 0.54 0.55 0.60 0.64 0.68 0.72 0.77 0.81 0.85 0.94 1.00
15 0.47 0.47 0.50 0.50 0.53 0.55 0.58 0.60 0.63 0.66 0.68 0.73 0.78 0.83 0.89 0.94 0.99 1.00
#9 #10 #11 #14 1678 1018 1114 1834 1238 2058 1534
31 234 2358 234
1418 1018 1678 1158 1934 1312 2212 1312 2538 1514 1678 2818 1858 134 134 134 134 134 134 134 234 234 234 234 234 234
134 234 3 4 5 6 7 8 9 10 12 14 16 18 20 22 24 26 28 30 32
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
0.59 0.59 0.65 0.66 0.72 0.77 0.83 0.89 0.94 1.00
0.50 0.47 0.58 0.58 0.51 0.58 0.51 0.58 0.50 0.51 0.56 0.60 0.65 0.70 0.74 0.79 0.84 0.93 1.00 0.47 0.48 0.50 0.52 0.55 0.57 0.59 0.62 0.64 0.69 0.73 0.78 0.83 0.87 0.92 0.97 1.00 0.58 0.59 0.62 0.66 0.69 0.72 0.76 0.79 0.82 0.89 0.96 1.00 0.58 0.59 0.62 0.65 0.68 0.71 0.74 0.77 0.80 0.86 0.91 0.97 1.00 0.51 0.51 0.53 0.55 0.57 0.59 0.61 0.63 0.65 0.69 0.73 0.77 0.80 0.84 0.88 0.92 0.96 1.00 0.58 0.59 0.61 0.64 0.67 0.69 0.72 0.75 0.77 0.82 0.88 0.93 0.98 1.00 0.51 0.51 0.53 0.55 0.57 0.58 0.60 0.62 0.64 0.67 0.71 0.74 0.77 0.81 0.84 0.88 0.91 0.95 0.98 1.00 0.58 0.59 0.61 0.63 0.65 0.67 0.69 0.71 0.73 0.77 0.81 0.85 0.89 0.93 0.97 1.00
*
5
Rebar E 312
Ccr Cmin fcmin 514 134 0.29
414
638 134 0.20
#4 414
8 134 0.16
5
712 134 0.13
#5 5
10 134 0.10
634
1018 134 0.13
#6 634
12 134 0.10
118
114
734
1158 134 0.13
#7 734
14 134 0.09
9
1312 134 0.08
#8 9
16 134 0.08
134 234 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18
20 22
0.10 0.21 0.24 0.35 0.45 0.56 0.67 0.78 0.89 1.00
0.13 0.23 0.26 0.36 0.47 0.57 0.68 0.78 0.88 0.99 1.00
0.10 0.19 0.21 0.30 0.39 0.47 0.56 0.65 0.74 0.82 0.91 1.00
0.13 0.22 0.24 0.33 0.42 0.50 0.59 0.68 0.77 0.86 0.94 1.00
0.09 0.16 0.18 0.26 0.33 0.41 0.48 0.55 0.63 0.70 0.78 0.85 0.93 1.00
0.08 0.16 0.18 0.26 0.33 0.41 0.49 0.57 0.65 0.73 0.80 0.88 0.96 1.00
0.08 0.14 0.16 0.23 0.29 0.35 0.42 0.48 0.55 0.61 0.68 0.74 0.81 0.87 0.94 1.00
0.08 0.10 0.16 0.22 0.28 0.34 0.40 0.46 0.52 0.58 0.64 0.70 0.76 0.82 0.88
1.00
0.14 0.16 0.23 0.29 0.36 0.43 0.50 0.57 0.64 0.71 0.78 0.85 0.91 0.98 1.00
0.14 0.16 0.22 0.28 0.34 0.40 0.46 0.52 0.58 0.64 0.70 0.76 0.82 0.89 0.95
1.00
0.14 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80
0.90 1.00
0.14 0.15 0.20 0.24 0.29 0.33 0.37 0.42 0.46 0.51 0.55 0.60 0.64 0.69 0.73
0.82 0.91
0.14 0.15 0.20 0.24 0.29 0.33 0.37 0.42 0.46 0.51 0.55 0.60 0.64 0.69 0.73
0.82 0.91
1.00 1.00
5. fc = adjustment factor for allowable load at actual edge distance. 6. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. Ccr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches).
45
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
2
#4
8
#5
4
#6
8
#7
1 #8
118
114
E
Scr Smin fsmin
312
14 134 0.89
414
17 218 0.89
6
24 3 0.89
5
20 212 0.89
938
3712 434 0.89
9
36 412 0.89
15
60 712 0.89
#9 #10 #11 #14 1678 1018 1114 1834 1238 2058 1534
6712 4012 812 518 0.89 0.89 45 558 0.89 75 938 0.89 4912 8212 614 1038 0.89 0.89 63 778 0.89
36 412 0.89
Sact (in.)
#5 5 712 212
1 #8 9 1312 412
1 8 #9
1
1 4 #10
1
46
134 2 3 4 5 6 7 8 9 10 12 14 16 18 20
0.83
0.83
0.83
0.83
0.83
0.83
0.83
1. E = Embedment depth (inches). 2. S act = actual spacing distance at which anchors are installed (inches). 3. S cr = critical spacing distance for 100% load (inches). 4. S min = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (S act - S min) / (S cr - S min)].
134 2 4 6 8 10 12 14 16 18 20 24 28 32 36 40 45 50 55 60 65 70 75 8212
0.90 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.98 1.00
0.89 0.90 0.91 0.91 0.92 0.93 0.93 0.94 0.95 0.97 0.98 0.99 1.00
0.89 0.90 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.99 1.00
0.89 0.90 0.90 0.91 0.91 0.92 0.92 0.93 0.94 0.95 0.96 0.97 0.99 1.00
0.89 0.90 0.91 0.91 0.92 0.93 0.94 0.95 0.96 0.97 0.99 1.00
0.89 0.90 0.90 0.91 0.91 0.92 0.92 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00
0.90 0.90 0.91 0.92 0.92 0.93 0.94 0.94 0.96 0.97 0.99 1.00
0.89 0.90 0.90 0.90 0.91 0.91 0.92 0.92 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00
0.90 0.90 0.91 0.92 0.92 0.93 0.94 0.94 0.96 0.97 0.99 1.00
0.89 0.90 0.90 0.90 0.91 0.91 0.92 0.93 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00
0.89 0.90 0.91 0.91 0.92 0.92 0.93 0.94 0.95 0.96 0.97 0.99 1.00
0.89 0.90 0.90 0.91 0.91 0.92 0.92 0.93 0.94 0.95 0.96 0.97 0.99 1.00
0.89 0.89 0.90 0.90 0.90 0.91 0.91 0.92 0.93 0.93 0.94 0.95 0.96 0.97 0.97 0.98 0.99 1.00
0.89 0.90 0.90 0.91 0.91 0.92 0.92 0.94 0.95 0.96 0.97 0.98 0.99 1.00
0.89 0.90 0.90 0.90 0.90 0.91 0.92 0.92 0.93 0.94 0.94 0.95 0.96 0.97 0.97 0.98 0.99 1.00
0.89 0.89 0.90 0.90 0.91 0.91 0.91 0.92 0.93 0.94 0.95 0.95 0.96 0.97 0.98 0.99 1.00
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
EDOT22
EDOT56
EMN22i
EDTA22P
RESULTS Non-sag/ thixotropic paste 129F (54C) 3054 psi (2 days) 3425 psi (14 days) 0.04% (24 hours) 10,053 psi (7 days) 393,000 psi (7 days) 46 min. @ 73 F (23C) 32 min. @ 90 F (32C)
Bond strength (moist cure) ASTM C-882 Water absorption Compressive modulus ASTM D-570 ASTM D-695 Compressive yield strength ASTM D-695 Gel time ASTM C-881
CHEMICAL RESISTANCE Very good to excellent against distilled water, dilute inorganic acids and alkalis. Fair to good against organic acids and alkalis, and many organic solvents. Poor against ketones. For more detailed information, visit www.strongtie.com or contact SimpsonStrongTie. SUGGESTED SPECIFICATIONS: Anchoring adhesives shall be a twocomponent high solids epoxy based system dispensed through a static mixing nozzle supplied by the manufacturer. Epoxy shall meet the minimum requirements of ASTM C881 and AASHTO M235 specication for Type I, II, IV, and V, Grade 3, Class C, and must develop a minimum 10,000 psi compressive yield strength after 7 day cure. Epoxy must have a heat deection temperature of a minimum 125F (52C). Adhesive shall be EDOT adhesive from SimpsonStrongTie, Pleasanton, CA. Anchors shall be installed per SimpsonStrongTie instructions for EDOT adhesive. Accessories: See pages 7277 for information on dispensing tools, mixing nozzles and other accessories.
1. Cartridge and bulk Estimation Guides are available on pages 4851. 2. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available on pages 7277. 3. Use only appropriate SimpsonStrongTie mixing nozzle in accordance with SimpsonStrongTie instructions. Modification or improper use of mixing nozzle may impair epoxy performance. 4. Metering pumps offered by third-party manufacturers.
Cure Schedule
Base Material Temperature Cure Time F C 40 4 72 hrs 60 16 24 hrs 80 27 24 hrs 100 38 24 hrs
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
3 45 28 32 20 16 9 13 8 11 6 9 6 8 5 7
4
4 34 21 24 15 12 7 10 6 8 5 7 4 6 4 5
3
5 27 17 19 12 10 5 8 5 6 4 5 3 5 3 4
3
6 22 14 16 10 8 5 6 4 5 3 4 3 4 2.5 3
2.2
7 19 12 14 9 7 4 6 3 5 3 4 2.4 3 2.1 3
1.9
16 8 5 6 4 3 1.7 2.4 1.4 2.0 1.2 1.7 1.1 1.4 0.9 1.3
0.8
17 8 5 6 4 3 1.6 2.3 1.4 1.9 1.1 1.6 1.0 1.4 0.9 1.2
0.8
18 7 5 5 3 3 1.5 2.1 1.3 1.8 1.1 1.5 0.9 1.3 0.8 1.2
0.7
19 7 4 5 3 3 1.4 2.0 1.2 1.7 1.0 1.4 0.9 1.2 0.8 1.1
0.7
20 7 4 5 3 2.4 1.4 1.9 1.2 1.6 1.0 1.3 0.8 1.2 0.7 1.0 0.7
1 14
1 12
Estimating Guide for 8.5 oz. Cartridge using Rebar - Installations per Cartridge
Rebar Size (no.) 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 Drill Bit Dia. (in.) 16 1 2 9 16 5 8 3 4 7 8 7 8 1 1 1 18 1 18 1 14 1 14 1 38 1 12 1 34 1 58 1 78
7
REBAR IN SOLID BASE MATERIAL HOLE DEPTH (inches) 2 90 50 74 39 32 16 25 13 22 11 19 10 17 9 9 4 9 4 3 60 34 49 26 21 11 17 9 15 8 13 7 11 6 6 3 6 3 4 45 25 37 20 16 8 13 7 11 6 9 5 8 5 5 2.2 4 2.1 5 36 20 30 16 13 6 10 5 9 5 8 4 7 4 4 1.8 3 1.7 6 30 17 25 13 11 5 8 4 7 4 6 3 6 3 3 1.5 3 1.4 7 26 14 21 11 9 5 7 4 6 3 5 3 5 3 3 1.3 2.5 1.2 8 22 13 18 10 8 4 6 3 6 3 5 3 4 2.3 2.3 1.1 2.2 1.1 9 20 11 16 9 7 4 6 3 5 3 4 2.3 4 2.1 2.0 1.0 1.9 0.9 10 18 10 15 8 6 3 5 3 4 2.3 4 2.1 3 1.9 1.8 0.9 1.7 0.9 11 16 9 13 7 6 3 5 2.5 4 2.1 3 1.9 3 1.7 1.6 0.8 1.6 0.8 12 15 8 12 7 5 3 4 2.2 4 1.9 3 1.7 3 1.6 1.5 0.7 1.4 0.7 13 14 8 11 6 5 2.4 4 2.1 3 1.8 3 1.6 3 1.4 1.4 0.7 1.3 0.7 14 13 7 11 6 5 2.3 4 1.9 3 1.6 3 1.5 2.4 1.3 1.3 0.6 1.2 0.6 15 12 7 10 5 4 2.1 3 1.8 3 1.5 3 1.4 2.3 1.2 1.2 0.6 1.2 0.6 16 11 6 9 5 4 2.0 3 1.7 3 1.4 2.4 1.3 2.1 1.2 1.1 0.6 1.1 0.5 17 11 6 9 5 4 1.9 3 1.6 3 1.4 2.2 1.2 2.0 1.1 1.1 0.5 1.0 0.5 18 10 6 8 4 4 1.8 3 1.5 2.4 1.3 2.1 1.2 1.9 1.0 1.0 0.5 1.0 0.5 19 9 5 8 4 3 1.7 3 1.4 2.3 1.2 2.0 1.1 1.8 1.0 0.9 0.5 0.9 0.4 20 9 5 7 4 3 1.6 3 1.3 2.2 1.1 1.9 1.0 1.7 0.9 0.9 0.4 0.9 0.4
Tables are estimations. Actual usage may vary depending on waste. Note: Online adhesive cartridge quantity estimating tools are available by visiting www.strongtie.com
48
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
3
116 73 84 53 42 24 33 20 28 17
4
87 55 63 40 31 18 25 15 21 13
8 3 8 1 2 1 2 5 8 5 8 3 4 3 4 7 8 7 8
3
16 1 2 9 16 5 8 3 4 7 8 7 8
7
5 70
44 51 32 25 14 20 12 17 10
6 58
37 42 27 21 12 17 10 14 8
7 50
31 36 23 18 10 14 9 12
Epoxy Adhesives
15 23
15 17 11 8 5 7 4 6
16 22
14 16 10 8 4 6 4 5
17 20
13 15 9 7 4 6 4 5
18 19
12 14 9 7 4 6 3 5
19 18
12 13 8 7 4 5 3 4
20
17 11 13 8 6 4 5 3 4
1 1 118
35 22 30 19 27 17
23 15 20 13 18 12
17 11 15 10 13 9
14 9 12 8 11 7
12 7 10 6 9 6
7 10 6 9 5 8 5
6 9 5 7 5 7 4
6 8 5 7 4 6 4
5 7 4 6 4 5 3
5 6 4 5 3 5 3
4 6 4 5 3 4 3
4 5 3 5 3 4 3
4 5 3 4 3 4 2
3 5 3 4 3 4 2
3 4 3 4 2 3 2
3 4 3 4 2 3 2
3 4 2 3 2 3 2
3 4 2 3 2 3 2
3 3 2 3 2 3 2
Estimating Guide for 22 oz. Cartridge using Rebar Installations per Cartridge
Rebar Drill Size Bit Dia. (no.) (in.)
3 3 4 4 5 5 6
2
233 131 192 102 82 41 65
3
155 87 128 68 55 27
4
116 65 96 51 41 21
5 93
52 77 41 33 16
6 78
44 64 34 27 14
7 67
37 55 29 23 12
8 58
33 48 25 20 10
14 33
19 27 15 12 6
15 31
17 26 14 11 5
16 29
16 24 13 10 5
17 27
15 23 12 10 5
18 26
15 21 11 9 5
19 25
14 20 11 9 4
20
23 13 19 10 8 4
16 1 2 9 16 5 8 3 4 7 8 7 8
7
47
26 38 20 16 8
42
24 35 18 15 7
39
22 32 17 14 7
36
20 30 16 13 6
6 7 7 8 8 9 9 10 10 11 11
35 57 30 49 27 44 24 23 12 22 11
44 23 38 20 33 18 29 16 16 8 15 7
33 17 29 15 25 13 22 12 12 6 11 6
26 14 23 12 20 11 18 10 9 5 9 4
22 12 19 10 16 9 15 8 8 4 7 4
19 10 16 9 14 8 13 7 7 3 6 3
16 9 14 7 12 7 11 6 6 3 6 3
15 8 13 7 11 6 10 5 5 3 5 2
13 7 11 6 10 5 9 5 5 2 4 2
12 6 10 5 9 5 8 4 4 2 4 2
11 6 10 5 8 4 7 4 4 2 4 2
10 5 9 5 8 4 7 4 4 2 3 2
9 5 8 4 7 4 6 3 3 2 3 2
9 5 8 4 7 4 6 3 3 2 3 1
8 4 7 4 6 3 6 3 3 1 3 1
8 4 7 4 6 3 5 3 3 1 3 1
7 4 6 3 5 3 5 3 3 1 2 1
7 4 6 3 5 3 5 3 2 1 2 1
7 3 6 3 5 3 4 2 2 1 2 1
Estimating Guide for 22 oz. Cartridge and Steel Screen Tubes Installations per Cartridge
Rod Drill Dia. Bit Dia. (in.) (in.) 312
49 31 18 13
4
43 27 15 11
5
34 22 12 9
6 29
18 10 8
7 25
16 9 7
8 21
14 8 6
16
17
18
19
20
21
8 1 2 5 8 3 4
3
16 11 16 7 8
9
17
11 6 5 6 4 5 4 5
Estimating Guide for 22 oz. Cartridge and Plastic Screen Tubes Installations per Cartridge
Rod Drill Dia. Bit Dia. (in.) (in.) 312
57 30 20 15
4
50 26 18 13
5
40 21 14 10
6 34
17 12 9
7 29
15 10 7
8 25
13 9 6
16
17
18
19
20
21
8 1 2 5 8 3 4
3
16 11 16 7 8
9
20
10 7 5 6 5 6 4 5
2 49
Tables are estimations. Actual usage may vary depending on waste. Note: Online adhesive cartridge quantity estimating tools are available by visiting www.strongtie.com
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 3 8 1 2 1 2 5 8 5 8 3 4 3 4 7 8 7 8
3
16 1 2 9 16 5 8 3 4 7 8 7 8
7
Estimating Guide for 56 oz. Cartridge using Rebar Installations per Cartridge
Rebar Size (no.) 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 Drill Bit Dia. (in.) REBAR IN SOLID BASE MATERIAL HOLE DEPTH (inches) 2 593 332 489 259 208 105 167 89 145 76 125 68 112 62 60 29 57 28 3 395 222 326 172 139 70 111 59 97 51 83 46 75 41 40 20 38 19 4 296 166 244 129 104 52 83 45 73 38 62 34 56 31 30 15 29 14 5 237 133 195 103 83 42 67 36 58 30 50 27 45 25 24 12 23 11 6 198 111 163 86 69 35 56 30 48 25 42 23 37 21 20 10 19 9 7 169 95 140 74 60 30 48 25 42 22 36 20 32 18 17 8 16 8 8 148 83 122 65 52 26 42 22 36 19 31 17 28 15 15 7 14 7 9 132 74 109 57 46 23 37 20 32 17 28 15 25 14 13 7 13 6 10 119 66 98 52 42 21 33 18 29 15 25 14 22 12 12 6 11 6 11 108 60 89 47 38 19 30 16 26 14 23 12 20 11 11 5 10 5 12 99 55 81 43 35 17 28 15 24 13 21 11 19 10 10 5 10 5 13 91 51 75 40 32 16 26 14 22 12 19 11 17 10 9 5 9 4 14 85 47 70 37 30 15 24 13 21 11 18 10 16 9 9 4 8 4 15 79 44 65 34 28 14 22 12 19 10 17 9 15 8 8 4 8 4 16 74 42 61 32 26 13 21 11 18 9 16 9 14 8 7 4 7 4 17 70 39 57 30 25 12 20 10 17 9 15 8 13 7 7 3 7 3 18 66 37 54 29 23 12 19 10 16 8 14 8 12 7 7 3 6 3 19 62 35 51 27 22 11 18 9 15 8 13 7 12 7 6 3 6 3 20 59 33 49 26 21 10 17 9 15 8 12 7 11 6 6 3 6 3
Estimating Guide for 56 oz. Cartridge and Steel Screen Tubes Installations per Cartridge
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 125 79 45 33 4 109 69 39 29 5 87 55 31 23 6 73 46 26 19 7 62 39 22 17 8 55 35 20 15 9 49 31 17 13 10 44 28 16 12 11 12 13 14 15 16 17 18 19 20 21
8 1 2 5 8 3 4
3
16 11 16 7 8
9
14 11
13 10
12 9
Estimating Guide for 56 oz. Cartridge and Plastic Screen Tubes Installations per Cartridge
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 146 76 52 38 4 128 66 45 33 5 102 53 36 26 6 85 44 30 22 7 73 38 26 19 8 64 33 23 17 9 57 30 20 15 10 51 27 18 13 11 12 13 14 15 16
8 1 2 5 8 3 4
3
16 11 16 7 8
9
17
18
19
20
21
17 12
15 11
14 10
50
Tables are estimations. Actual usage may vary depending on waste. Note: Online adhesive cartridge quantity estimating tools are available by visiting www.strongtie.com
16 1 2 9 16 5 8 3 4 7 8 7 8
7
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Epoxy Adhesives
8 3 8 1 2 1 2 5 8 5 8 3 4 3 4 7 8 7 8
3
16 1 2 9 16 5 8 3 4 7 8 7 8
7
Estimating Guide for 1 Gallon (128 oz.) System using Rebar Installations per Gallon
Rebar Size (no.) 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 Drill Bit Dia. (in.) REBAR IN SOLID BASE MATERIAL HOLE DEPTH (inches) 2 1354 759 1116 591 476 240 381 204 332 173 285 156 257 141 136 67 131 64 3 903 506 744 394 317 160 254 136 222 116 190 104 171 94 91 45 87 43 4 677 380 558 296 238 120 191 102 166 87 143 78 128 71 68 34 65 32 5 542 304 446 236 190 96 152 81 133 69 114 63 103 56 54 27 52 26 6 451 253 372 197 159 80 127 68 111 58 95 52 86 47 45 22 44 21 7 387 217 319 169 136 68 109 58 95 50 82 45 73 40 39 19 37 18 8 339 190 279 148 119 60 95 51 83 43 71 39 64 35 34 17 33 16 9 301 169 248 131 106 53 85 45 74 39 63 35 57 31 30 15 29 14 10 271 152 223 118 95 48 76 41 66 35 57 31 51 28 27 13 26 13 11 246 138 203 107 87 44 69 37 60 32 52 28 47 26 25 12 24 12 12 226 127 186 99 79 40 64 34 55 29 48 26 43 24 23 11 22 11 13 208 117 172 91 73 37 59 31 51 27 44 24 39 22 21 10 20 10 14 193 108 159 84 68 34 54 29 47 25 41 22 37 20 19 10 19 9 15 181 101 149 79 63 32 51 27 44 23 38 21 34 19 18 9 17 9 16 169 95 140 74 60 30 48 25 42 22 36 20 32 18 17 8 16 8 17 159 89 131 70 56 28 45 24 39 20 34 18 30 17 16 8 15 8 18 150 84 124 66 53 27 42 23 37 19 32 17 29 16 15 7 15 7 19 143 80 117 62 50 25 40 21 35 18 30 16 27 15 14 7 14 7 20 135 76 112 59 48 24 38 20 33 17 29 16 26 14 14 7 13 6
16 1 2 9 16 5 8 3 4 7 8 7 8
7
Estimating Guide for 1 Gallon (128 oz.) System using Steel Screen Tubes Installations per Gallon
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 285 180 102 76 4 250 158 89 66 5 200 126 71 53 6 167 105 60 44 7 143 90 51 38 8 125 79 45 33 9 111 70 40 29 10 100 63 36 27 11 12 13 14 15 16 17 18 19 20 21
8 1 2 5 8 3 4
3
16 11 16 7 8
9
32 24
30 22
27 20
19
18
17
16
15
14
13
13
Estimating Guide for 1 Gallon (128 oz.) System using Plastic Screen Tubes Installations per Gallon
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 334 173 119 86 4 293 152 104 76 5 234 121 83 60 6 195 101 69 50 7 167 87 59 43 8 146 76 52 38 9 130 67 46 34 10 117 61 41 30 11 12 13 14 15 16 17
8 1 2 5 8 3 4
3
16 11 16 7 8
9
18
19
20
21
38 27
35 25
32 23
22
20
19
18
17
16
15
14 51
Tables are estimations. Actual usage may vary depending on waste. Note: Online adhesive cartridge quantity estimating tools are available by visiting www.strongtie.com
Simpson Strong-Tie acrylic adhesive delivers consistent performance for high-strength anchor grouting in a wide range of weather conditions. Our acrylic formulations cure fast and are suitable for damp, wet or water-lled holes. Simpson Strong-Tie also makes dispensing acrylic adhesives easier than ever by providing a variety of manual and pneumatic tools as well as accessories designed to make dispensing adhesive as efcient as possible.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Acrylic Adhesive
AMN19Q
ADT813S
When the concrete temperature is at or below freezing, ensure any holes drilled in advance are free of frost or ice.
CHEMICAL RESISTANCE Very good to excellent against distilled water and inorganic acids. Fair to good against organic acids and alkalis, inorganic alkalis, and many organic solvents. Poor against ketones. For more detailed information, visit www.strongtie.com The performance of this product results from its unique formulation which is proprietary to Simpson Strong-Tie. The product may also be protected by one or more of U.S. Pats. 5,643,994; 5,965,635; 6,228,207, licensed from ITW.
SUGGESTED SPECIFICATIONS: Anchoring adhesive shall be a two-component acrylic based system supplied in manufacturer's standard side-by-side or coaxial cartridge and dispensed through a static-mixing nozzle supplied by the manufacturer. Adhesive shall meet the physical requirements of ASTM C-881 for Type I and IV, Grade 3, Class A, B and C and must develop a minimum 10,210 psi compressive yield strength after 7 day cure. Adhesive must have a heat deection temperature of a minimum 149F (65C). Adhesive shall be AT adhesive from Simpson Strong-Tie, Pleasanton, CA. Anchors shall be installed per Simpson Strong-Tie instructions for AT adhesive. Accessories: See pages 7277 for information on dispensing tools, mixing nozzles and other accessories. IMPORTANT See Pages 7071 for Installation Instructions
53
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Acrylic Adhesive
AT30
Cure Schedule
Base Material Temperature F 0 25 40 60 70 100 C -18 -4 4 16 21 38 Cure Time 24 hrs. 8 hrs. 4 hrs. 1 hr. 30 min. 20 min.
1. Refer to in-service temperature sensitivity chart for allowable bond strength reduction for in-service temperature. See page 225 for more information. 2. Tinst is the base material temperature during installation and curing of the adhesive. 3. Percent allowable load for Tinst = 0F (-18C) is to be used for Tinst between 0F (-18C) and 70F (21C). 4. Percent allowable load may be linearly interpolated for intermediate base material in-service temperatures. 5. C = (F-32) / 1.8
Tension Loads for Threaded Rod Anchors in Normal-Weight Concrete (continued on next page)
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Depth in. (mm) 134 (44) 312 (89) 412 (114) 218 (54) 414 (108) 6 (152) 212 (64) 4 (102) 512 (140) 7716 (189) 938 (238) Critical Edge Dist. in. (mm) 258 (67) 514 (133) 634 (171) 3316 (81) 638 (162) 9 (229) 334 (95) 558 (143) 712 (191) 1078 (276) 1418 (359) Critical Spacing Dist. in. (mm) 7 (178) 618 (156) 18 (457) 812 (216) 712 (191) 24 (610) 10 (254) 16 (406) 958 (244) 2934 (756) 3712 (953) Tension Load Based on Bond Strength f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 3,362 99 840 (15.0) (0.4) (3.7) 8,937 314 2,235 (39.8) (1.4) (9.9) 10,411 525 2,605 (46.3) (2.3) (11.6) 5,252 501 1,315 (23.4) (2.2) (5.8) 16,668 822 4,165 (74.1) (3.7) (18.5) 19,182 331 4,795 (85.3) (1.5) (21.3) 8,495 561 2,125 (37.8) (2.5) (9.5) 4,315 (19.2) 26,025 1,866 6,505 (115.8) (8.3) (28.9) 7,215 (32.1) 31,683 1,571 7,920 (140.9) (7.0) (35.2) Tension Load Based on Steel Strength F1554 Grade 36 Allowable lbs. (kN) A193 GR B7 Allowable lbs. (kN) F593 304SS Allowable lbs. (kN)
*
*See page 13 for an explanation of the load table icons
(9.5)
16
2,105 (9.4)
4,535 (20.2)
3,630 (16.1)
(12.7)
16
3,750 (16.7)
8,080 (35.9)
6,470 (28.8)
(15.9)
11
16
5,875 (26.1)
12,660 (56.3)
10,120 (45.0)
54
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13 for an explanation of the load table icons
Acrylic Adhesive
(19.1)
13
16
8,460 (37.6)
18,230 (81.1)
12,400 (55.2)
(22.2)
11,500 (51.2)
24,785 (110.2)
16,860 (75.0)
1 (25.4)
1116
15,025 (66.8)
32,380 (144.0)
22,020 (97.9)
118 (28.6)
1316
19,025 (84.6)
41,000 (182.4)
27,880 (124.0)
114 (31.8)
1516
23,490 (104.5)
50,620 (225.2)
34,420 (153.1)
1. Reference page 225 for oversize holes. 2. Allowable load must be the lesser of the bond or steel strength. 3. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 4. Refer to allowable load-adjustment factors for spacing and edge distance on pages 62, 64 and 65. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 7. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure and elevated-temperature conditions.
55
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13 for an explanation of the load table icons
Acrylic Adhesive
(9.5)
16
514 (133)
1,085 (4.8)
2,340 (10.4)
1,870 (8.3)
(12.7)
16
638 (162)
1,930 (8.6)
4,160 (18.5)
3,330 (14.8)
(15.9)
11
16
712 (191)
3,025 (13.5)
6,520 (29.0)
5,220 (23.2)
(19.1)
13
16
1018 (257)
4,360 (19.4)
9,390 (41.8)
6,385 (28.4)
(22.2)
1158 (295)
5,925 (26.4)
12,770 (56.8)
8,685 (38.6)
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1 (25.4)
1116
1312 (343)
7,740 (34.4)
16,680 (74.2)
11,345 (50.5)
118 (28.6)
1316
1514 (387)
9,800 (43.6)
21,125 (94.0)
14,365 (63.9)
114 (31.8)
1516
1678 (429)
12,100 (53.8)
26,075 (116.0)
17,730 (78.9)
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 63 and 65. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
56
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Acrylic Adhesive
#3 (9.5)
#4 (12.7)
16
4,800 (21.4)
#5 (15.9)
7,440 (33.1)
#6 (19.1)
10,560 (47.0)
#7 (22.2)
14,400 (64.1)
#8 (25.4)
118
18,960 (84.3)
1. Oversize holes may reduce load capacity. 2. Allowable load must be the lesser of the bond or steel strength. 3. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 4. Refer to allowable load-adjustment factors for spacing and edge distance on pages 62, 64 and 65. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 7. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure and elevated-temperature conditions.
57
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13 for an explanation of the load table icons
Acrylic Adhesive
#3 (9.5)
#4 (12.7)
16
8 (203)
638 (162)
3,060 (13.6)
#5 (15.9)
10 (254)
814 (210)
4,740 (21.1)
#6 (19.1)
12 (305)
1018 (257)
6,730 (29.9)
#7 (22.2)
14 (356)
1158 (295)
9,180 (40.8)
#8 (25.4)
118
16 (406)
1312 (343)
12,085 (53.8)
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 63 and 65. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
*
Min. End Dist. in. (mm) Tension Load Based on Tension Load Based on Steel Strength Bond Strength f'c 2500 psi (17.2 MPa) Concrete Ultimate Allowable lbs. (kN) lbs. (kN) 12,913 3,230 (57.4) (14.4) 21,838 5,460 (97.1) (24.3) F1554 Grade 36 Allowable lbs. (kN) 5,875 (26.1) 11,500 (51.2)
Edge
134"
6"or 8"
W=
d En "
(15.9)
7
11
16
(22.2)
10 (254.0) 15 (381.0)
6 (152.4) 8 (203.2)
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 4. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
Edge and end distances for threaded rod in concrete foundation stemwall corner installation
58
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13 for an explanation of the load table icons
Acrylic Adhesive
(9.5)
16
(12.7)
16
3,750 (16.7)
8,080 (35.9)
6,470 (28.8)
(15.9)
11
16
5,875 (26.1)
12,660 (56.3)
10,120 (45.0)
1. Oversize holes may reduce load capacity. 2. Allowable load must be the lesser of the bond or steel strength. 3. 100% of the allowable load is permitted at critical spacing. No reduction in spacing is allowed. 4. Refer to allowable load-adjustment factors for edge distance on page 66. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 7. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure and elevated-temperature conditions. 8. The allowable loads listed under allowable bond are based on a safety factor of 4.0.
*
*See page 13 for an explanation of the load table icons
(9.5)
16
(12.7)
16
1,930 (8.6)
4,160 (18.5)
3,330 (14.8)
(15.9)
11
16
3,025 (13.5)
6,520 (29.0)
5,220 (23.2)
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Refer to allowable load-adjustment factors for edge distance on page 66. 4. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 6. 100% of the allowable load is permitted at critical spacing. No reduction in spacing is allowed.
59
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Figure 1
EDGE DISTANCE 1" MIN. (TYP.)
Acrylic Adhesive
(12.7)
3
2 4
16 16
(19.1)
13
(19.1)
13
16
634 (171)
Figure 2
EDGE DISTANCE
Tension and Shear Loads for Threaded Rod Anchors in 6 and 8-Inch Normal-Weight Grout-Filled CMU
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Depth in. (mm) Min. Edge Dist. in. (mm) Min. End Dist. in. (mm) Min. Spacing Dist. in. (mm) 6 and 8-Inch Grout-Filled CMU Allowable Loads Based on CMU Strength Shear Parallel 9 Allowable lbs. (kN) 705 (3.1) 755 (3.4) 815 (3.6) 1,030 (4.6)
(12.7)
5
16 16
(15.9)
7
11
(22.2)
134" Edge
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. Values for 6- and 8-inch wide concrete masonry units (CMU) with a minimum specified compressive strength of masonry, f'm, at 28 days is 1500 psi. 3. Embedment depth is measured from the outside face of the concrete masonry unit for installations through a face shell. 4. Allowable loads may be increased 3313% for short-term loading due to wind or seismic forces where permitted by code. 5. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 6. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 7. Anchors must be spaced a minimum distance of four times the anchor embedment. 8. Shear load applied perpendicular to edge of CMU wall. 9. Shear load applied parallel to edge of CMU wall.
11" End
Tension and Shear Loads for Threaded Rod Anchors in Lightweight, Medium-Weight and Normal-Weight Hollow CMU
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Depth in. (mm) Min. Edge Dist. in. (mm) Min. End Dist. in. (mm) 6 and 8-Inch Hollow CMU Allowable Loads Based on CMU Strength
Figure 4
458"
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in Face Shell with Simpson Stong-Tie Stainless-Steel Screen Tube (See Figure 4) 3 3 4 458 1,400 280 1,326 265 8 9 16 (76.2) (101.6) (117.5) (6.2) (1.2) (5.9) (1.2) (9.5) 1 3 4 458 280 265 2 11 16 (76.2) (101.6) (117.5) (1.2) (1.2) (12.7) 5 3 4 458 280 265 8 7 8 (76.2) (101.6) (117.5) (1.2) (1.2) (15.9) 60
See Notes 1, 2, 3, 5, 6, 7 Above 1. Set drill to rotation only mode when drilling into hollow CMU. 2. Allowable loads may not be increased for short-term loading due to wind or seismic forces.
4"
Shear Tension Perpendicular 8 Allowable Allowable lbs. (kN) lbs. (kN) Anchor Installed in Cell Opening (Top-of-Wall) (See Figure 3) 414 134 11 17 650 285 (108) (44) (279) (432) (2.9) (1.3) 5 134 11 20 815 330 (127) (44) (279) (508) 3.6 (1.5) 12 134 11 48 1,120 410 (305) (44) (279) (1219) (5.0) (1.8) 11 48 1,385 290 12 134 (44) (279) (1219) (6.2) (1.3) (305)
END DISTANCE
Figure 3
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Conguration A (Shear)
SCREEN TUBE
Acrylic Adhesive
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. *See page 13 for explanation 2. All holes are drilled with a 1" diameter carbide-tipped drill bit of the load table icons with the drill set in the rotation-only mode. 3. The unreinforced brick walls must have a minimum thickness of 13 inches (three wythes of brick). 4. The allowable load is applicable only where in-place shear tests indicate minimum net mortar strength of 50 psi. 5. The allowable load for Configuration B and C anchors subjected to a combined tension and shear load is determined by assuming a straight-line relationship between allowable tension and shear. 6. The anchors installed in unreinforced brick walls are limited to resisting seismic or wind forces only. 7. Configuration A has a straight threaded rod or rebar embedded 8 inches into the wall with a 3132" diameter by 8-inch long screen tube (part # ATS758 or ATS758P). This configuration is designed to resist shear loads only. 8. Configuration B has a 34" threaded rod bent and installed at a 22.5-degree angle and installed 13 inches into the wall, to within 1-inch (maximum) of the exterior wall surface. This configuration is designed to resist tension and shear loads. The pre-bent threaded rod is installed with a 3132" diameter by 13-inch long screen tube (part # ATS7513 or ATS7513P). 9. Configuration C is designed to resist tension and shear forces. It consists of a 58" diameter, ASTM F1554 Grade 36 threaded rod and an 8" long steel sleeve (part # AST800) and a 3132" diameter by 8-inch long screen tube (part # ATS758). The steel sleeve has a plastic plug in one end. A 6" by 6" by 38" thick ASTM A 36 steel plate is located on the back face of the wall. 10. Special inspection requirements are determined by local jurisdiction and must be confirmed by the local building official. 11. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
SCREEN TUBE
Tension and Shear Loads for Threaded Rod Anchors in Lightweight, Medium-Weight and Normal-Weight Hollow CMU
Rod Dia. in. (mm) Drill Bit Dia. in. Embed. Depth in. (mm) Critical Edge Dist. in. (mm) Critical Spacing Dist. in. (mm) 8-inch Hollow CMU Allowable Loads Based on CMU Strength
58
HEX NUT
3 1
(9.5) (12.7)
5
(15.9)
Tension Shear Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in Face Shell w/Simpson Strong-Tie ATSP (Plastic) Screen Tube 3 12 8 1,545 310 1,385 275 9 16 (76.2) (305) (203) (6.9) (1.4) (6.2) (1.2) 3 12 8 1,510 300 1,305 260 3 4 (76.2) (305) (203) (6.7) (1.3) (5.8) (1.2) 3 12 8 1,590 320 1,345 270 7 8 (76.2) (305) (203) (7.1) (1.4) (6.0) (1.2)
* See page 13 for explanation of the load table icons
1. Threaded rods must comply with ASTM F1554 Grade 36 minimum. 2. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 3. Edge distances may be reduced to 4" with a corresponding 37% reduction in tension capacity. Shear capacity is unaffected. 4. Values for 8-inch wide, lightweight, medium-weight and normal-weight concrete masonry units with min. compressive strength of 1,900 psi and 114" thick face shell. 5. Embedment depth is measured from the outside face of the concrete masonry unit. 6. Refer to in-service temperature sensitivity chart for allowable load adjustment for temperature. 7. Allowable loads may not be increased for short-term loading due to wind or seismic forces. Wall design must satisfy applicable design standards and be capable of withstanding applied loads. 8. Set drill to rotation only mode when drilling into hollow CMU.
Installation Instructions for Conguration C: 1. Drill hole perpendicular to the wall to a depth of 8" with a 1" diameter carbide-tipped drill bit (rotation only mode). 2. Clean hole with oil-free compressed air and a nylon brush. 3. Fill 8" steel screen tube with mixed adhesive and insert into hole. 4. Insert steel sleeve slowly into screen tube (adhesive will displace). 5. Allow adhesive to cure (see cure schedule). 6. Drill through plastic plug in (inside) end of steel sleeve with 58" bit. 7. Drill completely through the wall with 58" carbide tipped concrete drill bit (rotation mode only). 8. Insert 58" rod through hole and attach metal plate and nut.
61
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
AT Technical Information
Load Adjustment Factors for AT Adhesive in Normal-Weight Concrete: Edge Distance, Tension Load
How to use these charts: 1. The following tables are for reduced edge distance. 2. Locate the anchor size to be used for either a tension and/or shear load application. 3. Locate the embedment (E) at which the anchor is to be installed. 4. Locate the edge distance (Cact) at which the anchor is to be installed. 5. The load-adjustment factor (fc) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple edges are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable tension load based on bond strength values only.
Acrylic Adhesive
*
1
#3 412 634 134 0.65 0.65 0.67 0.74 0.81 0.88 0.95 1.00 218 3316 134 0.50 0.50 0.59 0.93 1.00
312 514 134 0.59 0.59 0.62 0.74 0.85 0.97 1.00
#4 414 638 134 0.50 0.50 0.53 0.64 0.74 0.85 0.96 1.00
6 9 134 0.65 0.65 0.66 0.71 0.76 0.81 0.86 0.90 0.95 1.00
#4 712 1114 134 0.65 0.65 0.66 0.70 0.73 0.77 0.81 0.84 0.88 0.92 0.95 0.99 1.00
#5 938 1418 134 0.61 0.61 0.62 0.65 0.68 0.71 0.74 0.78 0.81 0.84 0.87 0.90 0.93 0.96 1.00 338 5116 134 0.50 0.50 0.54 0.69 0.84 0.99 1.00
#6 1114 1678 134 0.56 0.56 0.57 0.60 0.63 0.65 0.68 0.71 0.74 0.77 0.80 0.83 0.86 0.89 0.92 0.95 0.97 1.00
512 712 134 0.50 0.50 0.52 0.61 0.70 0.78 0.87 0.96 1.00
634 1018 134 0.50 0.50 0.51 0.57 0.63 0.69 0.75 0.81 0.87 0.93 0.99 1.00
1 #7 1318 1958 134 0.52 0.52 0.55 0.58 0.63 0.69 0.74 0.80 0.85 0.90 0.96 1.00 412 634 134 0.44 0.44 0.55 0.69 0.92 1.00 9 1312 134 0.44 0.44 0.49 0.55 0.64 0.74 0.83 0.93 1.00 #8 15 2212 134 0.39 0.39 0.42 0.46 0.51 0.57 0.63 0.69 0.75 0.81 0.87 0.93 0.99 1.00 518 734 234 0.47 0.47 0.60 0.81 1.00
118 1018 1514 234 0.47 0.47 0.52 0.61 0.69 0.78 0.86 0.95 1.00 #9 1678 2538 234 0.43 0.43 0.46 0.51 0.56 0.61 0.66 0.71 0.76 0.81 0.86 0.91 0.97 1.00 558 8716 234 0.47 0.47 0.59 0.77 0.96 1.00
114 1114 1678 234 0.47 0.47 0.52 0.59 0.67 0.74 0.82 0.89 0.97 1.00 #10 1834 2818 234 0.43 0.43 0.46 0.50 0.55 0.59 0.64 0.68 0.73 0.77 0.82 0.86 0.91 0.95 1.00 #11 2058 31 234 0.43 0.43 0.46 0.50 0.54 0.58 0.62 0.66 0.70 0.74 0.78 0.82 0.86 0.90 0.94 0.98 1.00
734 1158 134 0.49 0.49 0.54 0.61 0.71 0.81 0.92 1.00
62
1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. Ccr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual edge distance.
6. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
AT Technical Information
Load Adjustment Factors for AT Adhesive in Normal-Weight Concrete: Edge Distance, Shear Load
How to use these charts: 1. The following tables are for reduced edge distance. 2. Locate the anchor size to be used for either a tension and/or shear load application. 3. Locate the embedment (E) at which the anchor is to be installed. 4. Locate the edge distance (Cact) at which the anchor is to be installed. 5. The load-adjustment factor (fc) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple edges are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable shear load based on concrete edge distance values only.
Acrylic Adhesive
Edge Rebar Dist. E Cact Ccr (in.) Cmin fcmin 134 234 3 312 4 412 5 512 6 612 7 712 8 812 9 912 10 1012 11 1112 12 See Notes Below
#3 312 6 134 0.19 0.19 0.38 0.43 0.52 0.62 0.71 0.81 0.90 1.00 412 6 134 0.39 0.39 0.53 0.57 0.64 0.71 0.78 0.86 0.93 1.00 218 638 134 0.18 0.18 0.36 0.40 0.49 0.58 0.67 0.76 0.84 0.93 1.00
2
6 638 134 0.25 0.25 0.41 0.45 0.53 0.61 0.70 0.78 0.86 0.94 1.00
#4 414 8 134 0.16 0.16 0.29 0.33 0.40 0.46 0.53 0.60 0.66 0.73 0.80 0.87 0.93 1.00 712 8 134 0.25 0.25 0.37 0.40 0.46 0.52 0.58 0.64 0.70 0.76 0.82 0.88 0.94 1.00 212 712 134 0.12 0.12 0.27 0.31 0.39 0.46 0.54 0.62 0.69 0.77 0.85 0.92 1.00
8
938 712 134 0.14 0.14 0.29 0.33 0.40 0.48 0.55 0.63 0.70 0.78 0.85 0.93 1.00
#5 512 10 134 0.10 0.10 0.21 0.24 0.29 0.35 0.40 0.45 0.51 0.56 0.62 0.67 0.73 0.78 0.84 0.89 0.95 1.00 938 10 134 0.14 0.14 0.24 0.27 0.32 0.37 0.43 0.48 0.53 0.58 0.64 0.69 0.74 0.79 0.84 0.90 0.95 1.00 338 1018 134 0.10 0.10 0.21 0.23 0.29 0.34 0.40 0.45 0.50 0.56 0.61 0.66 0.72 0.77 0.83 0.88 0.93 0.99 1.00
4
1114 1018 134 0.14 0.14 0.24 0.27 0.32 0.37 0.42 0.47 0.53 0.58 0.63 0.68 0.73 0.78 0.83 0.88 0.94 0.99 1.00
*
#6 634 1114 12 12 134 134 0.10 0.14 0.10 0.14 0.19 0.22 0.21 0.24 0.25 0.29 0.30 0.33 0.34 0.37 0.39 0.41 0.43 0.45 0.47 0.50 0.52 0.54 0.56 0.58 0.60 0.62 0.65 0.66 0.69 0.71 0.74 0.75 0.78 0.79 0.82 0.83 0.87 0.87 0.91 0.92 0.96 0.96 1.00 1.00
*See page 13 for an explanation of the load table icons
414 638 134 0.15 0.15 0.33 0.38 0.47 0.56 0.66 0.75 0.84 0.93 1.00
512 712 134 0.11 0.11 0.26 0.30 0.38 0.46 0.54 0.61 0.69 0.77 0.85 0.92 1.00
634 1018 134 0.11 0.11 0.22 0.24 0.30 0.35 0.40 0.46 0.51 0.56 0.61 0.67 0.72 0.77 0.83 0.88 0.93 0.99 1.00
8
1318 1158 134 0.09 0.09 0.18 0.21 0.30 0.39 0.48 0.57 0.67 0.76 0.85 0.94 1.00
1 #7 734 1318 14 14 134 134 0.09 0.09 0.09 0.09 0.16 0.16 0.18 0.18 0.26 0.26 0.33 0.33 0.41 0.41 0.48 0.48 0.55 0.55 0.63 0.63 0.70 0.70 0.78 0.78 0.85 0.85 0.93 0.93 1.00 1.00 #8 412 1312 134 0.08 0.08 0.16 0.18 0.26 0.33 0.41 0.49 0.57 0.65 0.73 0.80 0.88 0.96 1.00 9 1312 134 0.08 0.08 0.16 0.18 0.26 0.33 0.41 0.49 0.57 0.65 0.73 0.80 0.88 0.96 1.00 15 1312 134 0.09 0.09 0.17 0.19 0.26 0.34 0.42 0.50 0.57 0.65 0.73 0.81 0.88 0.96 1.00 9 16 134 0.08 0.08 0.14 0.16 0.23 0.29 0.35 0.42 0.48 0.55 0.61 0.68 0.74 0.81 0.87 0.94 1.00 15 16 134 0.09 0.09 0.15 0.17 0.23 0.30 0.36 0.43 0.49 0.55 0.62 0.68 0.74 0.81 0.87 0.94 1.00
118
114
*See page 13 for an explanation of the load table icons
734 1158 134 0.08 0.08 0.17 0.20 0.29 0.38 0.48 0.57 0.66 0.76 0.85 0.94 1.00
518 1018 1678 558 1114 1834 1514 1514 1514 1678 1678 1678 234 234 234 234 234 234 0.14 0.12 0.12 0.14 0.12 0.12 0.14 0.16 0.23 0.29 0.36 0.43 0.50 0.57 0.64 0.71 0.78 0.85 0.91 0.98 1.00 0.12 0.14 0.21 0.28 0.35 0.42 0.49 0.56 0.63 0.70 0.77 0.84 0.91 0.98 1.00 0.12 0.14 0.21 0.28 0.35 0.42 0.49 0.56 0.63 0.70 0.77 0.84 0.91 0.98 1.00 0.14 0.16 0.22 0.28 0.34 0.40 0.46 0.52 0.58 0.64 0.70 0.76 0.82 0.89 0.95 1.00 0.12 0.14 0.20 0.26 0.32 0.38 0.45 0.51 0.57 0.63 0.70 0.76 0.82 0.88 0.95 1.00 0.12 0.14 0.20 0.26 0.32 0.38 0.45 0.51 0.57 0.63 0.70 0.76 0.82 0.88 0.95 1.00
1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. Ccr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual edge distance.
6. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
63
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
AT Technical Information
Load Adjustment Factors for AT Adhesive in Normal-Weight Concrete: Spacing, Tension Load
How to use these charts: 1. The following tables are for reduced spacing. 2. Locate the anchor size to be used for either a tension and/or shear load application. 3. Locate the embedment (E) at which the anchor is to be installed. 4. Locate the spacing (Sact) at which the anchor is to be installed. 5. The load-adjustment factor (fs) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple spacings are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable tension load based on bond strength values only.
Acrylic Adhesive
* 8
1
Sact (in.)
134 7
7
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
64
0.57 0.57 0.58 0.61 0.65 0.68 0.72 0.75 0.79 0.86 0.93 1.00
6 24 3 0.80
0.80 0.81 0.82 0.82 0.83 0.85 0.86 0.87 0.89 0.90 0.92 0.95 0.97 1.00
0.59 0.62 0.65 0.67 0.70 0.73 0.78 0.84 0.89 0.95 1.00
0.80 0.80 0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.89 0.90 0.92 0.94 0.96 1.00
0.80 0.81 0.82 0.82 0.83 0.84 0.84 0.86 0.87 0.89 0.90 0.92 0.94 0.97 1.00
0.58 0.61 0.63 0.66 0.68 0.71 0.75 0.80 0.85 0.90 0.95 1.00
0.80 0.81 0.81 0.82 0.82 0.83 0.84 0.85 0.86 0.88 0.89 0.91 0.93 0.95 0.98 1.00
0.58 0.60 0.61 0.63 0.65 0.68 0.72 0.75 0.79 0.82 0.86 0.93 1.00
0.80 0.81 0.81 0.82 0.82 0.83 0.84 0.85 0.86 0.87 0.89 0.91 0.93 0.95 0.97 1.00
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
AT Technical Information
Spacing Tension (fs) (contd)
Dia. Rebar E Scr Smin fsmin
7
*
1 #7 1318 5212 658 0.80 412 18 214 0.57 0.59 0.62 0.65 0.67 0.73 0.78 0.84 0.89 0.95 1.00 9 1534 412 0.58 #8 15 60 712 0.80 518 2012 258 0.57 0.58 0.60 0.63 0.65 0.70 0.75 0.80 0.84 0.89 0.99 1.00 1018 1734 518 0.58 118 #9 1678 6712 812 0.80 558 2212 278 0.57 0.57 0.59 0.62 0.64 0.68 0.73 0.77 0.81 0.86 0.95 1.00 114 1114 1934 558 0.58 #10 1834 75 938 0.80 #11 2058 8212 1038 0.80
*See page 13 for an explanation of the load table icons
Sact (in.)
2 3 4 5 6 8 10 12 14 16 20 24 28 32 36 40 50 60 70 80 83
378 1512 2 0.57 0.57 0.60 0.63 0.67 0.70 0.76 0.82 0.89 0.95 1.00
734 1358 378 0.58 0.59 0.63 0.67 0.76 0.84 0.93 1.00
Acrylic Adhesive
0.81 0.81 0.82 0.83 0.84 0.86 0.88 0.89 0.91 0.93 0.95 0.99 1.00
0.80 0.81 0.82 0.82 0.83 0.85 0.86 0.88 0.89 0.91 0.92 0.96 1.00
0.81 0.81 0.82 0.83 0.84 0.85 0.87 0.88 0.89 0.91 0.94 0.97 1.00
0.80 0.81 0.81 0.82 0.83 0.84 0.86 0.87 0.88 0.89 0.92 0.95 0.98 1.00
0.80 0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.88 0.91 0.94 0.97 0.99 1.00
Load Adjustment Factors for AT Adhesive in Normal-Weight Concrete: Spacing, Shear Load How to use these charts:
1. The following tables are for reduced spacing. 2. Locate the anchor size to be used for either a tension and/or shear load application. 3. Locate the embedment (E) at which the anchor is to be installed. 4. Locate the spacing (Sact) at which the anchor is to be installed. 5. The load-adjustment factor (fs) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple spacings are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable shear load based on concrete edge distance values only.
* 8
1
Sact (in.)
134 258
7
212 334 114 0.90 0.91 0.93 0.95 0.97 0.99 1.00
1 #7 734 1158 378 0.83 412 634 214 0.90 #8 9 1312 412 0.83 518 734 258 0.90
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches).
5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
65
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
AT Technical Information
Load Adjustment Factors for AT Adhesive in Sand-Lightweight Concrete: Edge Distance, Tension and Shear Loads How to use these charts:
1. The following tables are for reduced edge distance only. 2. Locate the anchor size to be used for either a tension and/or shear load application. 3. Locate the embedment (E) at which the anchor is to be installed. 4. Locate the edge distance (Cact) at which the anchor is to be installed. 5. The load-adjustment factor (fc) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load-adjustment factor. 7. Reduction factors for multiple edges are multiplied together. 8. Adjustment factors do not apply to allowable steel strength values. 9. Adjustment factors are to be applied to allowable tension load based on bond strength values or allowable shear load based on concrete edge distance values only.
Acrylic Adhesive
*
1
*
1
312 514 134 0.59 0.59 0.62 0.65 0.68 0.71 0.74 0.77 0.80 0.82 0.85 0.88 0.91 0.94 0.97 1.00
218 318 134 0.50 0.50 0.59 0.68 0.77 0.86 0.95 1.00
1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. Ccr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual edge distance. 6. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
66
414 638 134 0.50 0.50 0.53 0.55 0.58 0.61 0.64 0.66 0.69 0.72 0.74 0.77 0.80 0.82 0.85 0.88 0.91 0.93 0.96 0.99 1.00
212 334 134 0.50 0.50 0.56 0.63 0.69 0.75 0.81 0.88 0.94 1.00
5 712 134 0.50 0.50 0.52 0.54 0.57 0.59 0.61 0.63 0.65 0.67 0.70 0.72 0.74 0.76 0.78 0.80 0.83 0.85 0.87 0.89 0.91 0.93 0.96 0.98 1.00
312 514 134 0.35 0.35 0.40 0.44 0.49 0.54 0.58 0.63 0.68 0.72 0.77 0.81 0.86 0.91 0.95 1.00
218 318 134 0.18 0.18 0.33 0.48 0.63 0.78 0.93 1.00
414 638 134 0.15 0.15 0.20 0.24 0.29 0.33 0.38 0.43 0.47 0.52 0.56 0.61 0.66 0.70 0.75 0.79 0.84 0.89 0.93 0.98 1.00
212 334 134 0.12 0.12 0.23 0.34 0.45 0.56 0.67 0.78 0.89 1.00
5 712 134 0.11 0.11 0.15 0.19 0.23 0.26 0.30 0.34 0.38 0.42 0.46 0.50 0.54 0.57 0.61 0.65 0.69 0.73 0.77 0.81 0.85 0.88 0.92 0.96 1.00
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Drill Bit Dia. (in.) 16 1 2 9 16 5 8 11 16 3 4 13 16 7 8 15 16 1 1116 118 1316 114 1516 138
7
Acrylic Adhesive
Estimating Guide for 9.6 oz Cartridge using Rebar - Installations per Cartridge
Rebar Drill Size Bit Dia. (no.) (in.) 3 4 4 5 6 7 8 9 10 11 2 9 16 5 8 3 4 7 8 1 118 114 138 158
1
Estimating Guide for 9.6 oz Cartridge and Steel Screen Tubes - Installations per Cartridge
Rod Dia. (in.)
3
THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 20 13 7 5 4 18 11 6 4 412 16 10 5 4 5 14 9 5 3 512 13 8 4 3 6 12 7 4 3 612 11 7 3 2 7 10 6 3 2 712 9 6 3 2 8 9 5 3 2 9 8 5 2 2 10 7 4 2 1 11 12 13 14 15 16 17
8 1 2 5 8 3 4
2 1
2 1
Estimating Guide for 9.6 oz Cartridge and Opti-Mesh Screen Tubes - Installations per Cartridge
Rod Dia. (in.)
3
8 1 2 5 8 3 4
THREADED ROD INSERTED IN OPTI-MESH SCREEN TUBE HOLE DEPTH (inches) 4 17 9 6 4 412 15 8 5 4 5 14 7 5 3 512 12 7 4 3 6 11 6 4 3 612 10 5 4 3 7 10 5 3 2 712 9 5 3 2 8 8 4 3 2 9 7 4 2 2 10 7 3 2 1 11 12 13 14 15 16 17 18 19 20 21
2 2
2 1
2 1
Tables are estimations. Actual usage may vary depending on waste. Note: Online adhesive cartridge quantity estimating tools are available by visiting www.strongtie.com
67
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 3 8 1 2 1 2 5 8 5 8 3 4 3 4 7 8 7 8
3
16 1 2 9 16 5 8 11 16 3 4 13 16 7 8 15 16
7
Acrylic Adhesive
Estimating Guide for 12.5 oz. Cartridge using Rebar Installations per Cartridge
Rebar Size (no.) 3 4 4 5 6 7 8 9 10 11 Drill Bit Dia. (in.) REBAR IN SOLID BASE MATERIAL HOLE DEPTH (inches) 2 77 114 60 48 39 34 29 26 26 13 3 52 76 40 32 26 23 19 17 18 9 4 39 57 30 24 19 17 15 13 13 7 5 31 45 24 19 16 14 12 10 11 5 6 26 38 20 16 13 11 10 9 9 4 7 22 32 17 14 11 10 8 7 8 4 8 19 28 15 12 10 8 7 7 7 3 9 17 25 13 11 9 8 6 6 6 3 10 15 23 12 10 8 7 6 5 5 3 11 14 21 11 9 7 6 5 5 5 2 12 13 19 10 8 6 6 5 4 4 2 13 12 17 9 7 6 5 4 4 4 2 14 11 16 9 7 6 5 4 4 4 2 15 10 15 8 6 5 5 4 3 4 2 16 10 14 8 6 5 4 4 3 3 2 17 9 13 7 6 5 4 3 3 3 2 18 9 13 7 5 4 4 3 3 3 1 19 8 12 6 5 4 4 3 3 3 1 20 8 11 6 5 4 3 3 3 3 1
Estimating Guide for 12.5 oz. Cartridge and Steel Screen Tubes Installations per Cartridge
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 29 18 10 8 4 25 16 9 7 412 23 14 8 6 5 20 13 7 5 512 18 12 7 5 6 17 11 6 4 612 16 10 6 4 7 15 9 5 4 712 14 9 5 4 8 13 8 5 3 9 11 7 4 3 10 10 6 4 3 11 12 13 14 15 16 17
8 1 2 5 8 3 4
3
16 11 16 7 8
9
3 2
3 2
3 2
Estimating Guide for 12.5 oz. Cartridge and Plastic Screen Tubes Installations per Cartridge
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 34 18 12 9 4 30 15 11 8 412 26 14 9 7 5 24 12 8 6 512 22 11 8 6 6 20 10 7 5 612 18 9 6 5 7 17 9 6 4 712 16 8 6 4 8 15 8 5 4 9 13 7 5 3 10 12 6 4 3 11 12 13 14 15 16 17 18 19 20 21
8 1 2 5 8 3 4
3
16 11 16 7 8
9
4 3
4 3
3 2
68
Tables are estimations. Actual usage may vary depending on waste. Note: Online adhesive cartridge quantity estimating tools are available by visiting www.strongtie.com
2 9 16 5 8 3 4 7 8
1
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 3 8 1 2 1 2 5 8 5 8 3 4 3 4 7 8 7 8
3
16 1 2 9 16 5 8 11 16 3 4 13 16 7 8 15 16
7
Acrylic Adhesive
Estimating Guide for 30 oz. Cartridge using Rebar Installations per Cartridge
Rebar Size (no.) 3 4 4 5 6 7 8 9 10 11 Drill Bit Dia. (in.) REBAR IN SOLID BASE MATERIAL HOLE DEPTH (inches) 2 178 262 139 112 89 78 67 60 61 31 3 119 175 92 74 60 52 45 40 40 20 4 89 131 69 56 45 39 33 30 30 15 5 71 105 55 45 36 31 27 24 24 12 6 59 87 46 37 30 26 22 20 20 10 7 51 75 40 32 26 22 19 17 17 9 8 45 65 35 28 22 19 17 15 15 8 9 40 58 31 25 20 17 15 13 13 7 10 36 52 28 22 18 16 13 12 12 6 11 32 48 25 20 16 14 12 11 11 6 12 30 44 23 19 15 13 11 10 10 5 13 27 40 21 17 14 12 10 9 9 5 14 25 37 20 16 13 11 10 9 9 4 15 24 35 18 15 12 10 9 8 8 4 16 22 33 17 14 11 10 8 8 8 4 17 21 31 16 13 11 9 8 7 7 4 18 20 29 15 12 10 9 7 7 7 3 19 19 28 15 12 9 8 7 6 6 3 20 18 26 14 11 9 8 7 6 6 3
2 9 16 5 8 3 4 7 8
1
Estimating Guide for 30 oz. Cartridge and Steel Screen Tubes Installations per Cartridge
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 67 42 24 18 4 59 37 21 16 412 52 33 19 14 5 47 30 17 12 512 43 27 15 11 6 39 25 14 10 612 36 23 13 10 7 33 21 12 9 712 31 20 11 8 8 29 19 10 8 9 26 16 9 7 10 23 15 8 6 11 12 13 14 15 16 17
8 1 2 5 8 3 4
3
16 11 16 7 8
9
8 6
7 5
6 5
Estimating Guide for 30 oz. Cartridge and Plastic Screen Tubes Installations per Cartridge
Rod Dia. (in.) Drill Bit Dia. (in.) THREADED ROD INSERTED IN SCREEN TUBE HOLE DEPTH (inches) 312 78 41 28 20 4 69 36 24 18 412 61 32 22 16 5 55 28 19 14 512 50 26 18 13 6 46 24 16 12 612 42 22 15 11 7 39 20 14 10 712 37 19 13 9 8 34 18 12 9 9 31 16 11 8 10 27 14 10 7 11 12 13 14 15 16 17 18 19 20 21
8 1 2 5 8 3 4
3
16 11 16 7 8
9
9 6
8 6
7 5
Tables are estimations. Actual usage may vary depending on waste. Note: Online adhesive cartridge quantity estimating tools are available by visiting www.strongtie.com
69
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
seconds (min.)
psi min.
80
2. Blow Remove dust from hole with oil-free compressed air for a minimum of 4 seconds. Compressed air nozzle must reach the bottom of the hole.
4 cycles
3. Brush Clean with a nylon brush for (min.) a minimum of 4 cycles. Brush should provide resistance to insertion. If no resistance is felt, the brush is worn and must be replaced.
seconds (min.)
psi min.
80
4. Blow Remove dust from hole with oil-free compressed air for a minimum of 4 seconds. Compressed air nozzle must reach the bottom of the hole.
Anchoring Adhesives
cartridge preparation:
1. CheckCheck expiration date on product label. Do not use expired product. Product is usable until end of printed expiration month. 2. Open Open cartridge per package instructions.
3. Attach Attach proper Simpson StrongTie nozzle and extension to cartridge. Do not 4. InsertInsert cartridge modify nozzle. into dispensing tool.
Refer to www.strongtie.com for proper mixing nozzle and dispensing tool part number.
Water-Filled Holes:
1. Fill Fill hole completely full, starting from bottom of hole to prevent water pockets. Withdraw nozzle as hole lls up. 2. Insert Insert clean, oil-free anchor, turning slowly until the anchor contacts the bottom of the hole. Threaded rod or rebar 3. Do not disturb Do not disturb anchor until fully cured. (See cure schedule.)
1. InstallInstall Simpson Strong-Tie ARC adhesive retaining cap. Refer to page 74 or visit www.strongtie.com for proper ARC size.
2. FillFill hole 12 23 full, starting from bottom of hole to prevent air pockets. Withdraw nozzle as hole lls up.
3. InsertInsert clean, oil-free anchor, turning slowly until the anchor contacts the bottom of the hole.
4. Do not disturbDo not disturb anchor until fully cured (see cure schedule).
70
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Anchoring Adhesives
1. FillFill screen completely. Fill from the bottom of the screen and withdraw the nozzle as the screen lls to prevent air pockets. (Opti-Mesh screens: Close integral cap after lling.)
3. InsertInsert clean, oil-free anchor, turning slowly until the anchor contacts the bottom of the screen.
4. Do not disturbDo not disturb anchor until fully cured. (See cure schedule for specic adhesive.)
filling the hole: V GC Vinylester Glass Capsule (Hammer Capsule) Prepare the hole per instructions Hole Preparation.
1. InsertInsert the VGC capsule(s) to the bottom of the hole (either end rst).
3. DriveDrive stud or rod to the bottom of the hole. Spinning of the stud or rod is not required.
4. Do not disturbDo not disturb anchor until fully cured. (See cure schedule for VGC.) VGC is not recommended for overhead applications.
71
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Adhesive Accessories
Adhesive Dispensing Tools
Our heavy-duty tools are designed to work with our cartridges for trouble-free dispensing. Each manual tool provides a 26:1 drive mechanism for easier dispensing of high-viscosity adhesive.
Adhesive Accessories
Manual Dispensing Tool for SET-XP10 Adhesive and other Single Cartridge Adhesives The CDT10S features a steel carriage for ultimate durability and is engineered for continuous, high-volume use. The CDT10S also features double-gripping plates that help extend tool life.
NEW
CDT10S
CDT10S
EDT22S
Manual Dispensing Tool for 22 oz. Adhesive Cartridges The EDT22S epoxy adhesive tool features a steel carriage and is engineered for high-volume, continuous use. The tool can be easily convert from dispensing a 22 oz. 1:1 ratio cartridge to a 16.5 oz. 2:1 ratio cartridge.
EDT22CKT
EDT22S
Battery-Powered Dispensing Tool for 22 oz. Cartridges The EDT22CKT offers power dispensing without the need for a hose or compressor. The tool features dosage and rate control for maximum efciency. Each battery charge dispenses approximately 25 cartridges and recharging takes 1 hour. Tool comes complete with two 14.4V batteries and a charger.
NEW
EDTA22P
Pneumatic Dispensing Tool for 22 oz. Cartridges The EDTA22P tool features an optional suitcase handle adapter for the ultimate in tool conguration and dispensing convenience. The suitcase option enables easier and time-saving ground-level doweling. The heavyduty tool comes with a custom, blow-molded plastic carrying case.
NEW
EDTA56P
Description Premium tool for singletube cartridges Manual tool for 22 oz. cartridges Battery-powered tool for 22 oz. cartridges Pneumatic tool for 22 oz. cartridges1, 2 Pneumatic tool for 56 oz. cartridges1,2
EDTA22P
1. Air supply attachment is 14-18 NPT (male) thread. 2. Recommended operating air pressure is between 80100 psi.
EDTA56P
Pneumatic Dispensing Tool for 56 oz. Cartridges The EDTA56P tool features an optional suitcase handle adapter for the ultimate in tool conguration and dispensing convenience. The suitcase option enables easier and time-saving ground-level doweling. The heavyduty tool comes with a custom, blow-molded plastic carrying case.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Adhesive Accessories
Acrylic Adhesive Dispensing Tools
NEW
ADT813S
Manual Dispensing Tool for 12.5 oz. Cartridges The ADT813S features a steel carriage for ultimate durability. The ADT813S also features double-gripping plates that help extend tool life.
NEW
ADT30S
Manual Dispensing Tool for 30 oz. Adhesive Cartridges The ADT30S features a steel carriage for ultimate durability and is engineered for continuous, high-volume use. The ADT30S also features double-gripping plates that help extend tool life.
ADT813S
Adhesive Accessories
ADT30CKT
Battery Powered Dispensing Tool for 30 oz. Cartridges The ADT30CKT offers power dispensing without the need for a hose or compressor. The tool features dosage and rate control for maximum efciency. Each battery charge dispenses approximately 25 cartridges and recharging takes 1 hour. The tool comes complete with two 14.4V batteries and a charger.
NEW
ADT30S
ADTA30P
Pneumatic Dispensing Tool for 30 oz. Cartridges The ADTA30P tool features an optional suitcase handle adapter for exible tool conguration and dispensing convenience. The suitcase option enables easier and time-saving ground-level doweling. The heavy-duty tool comes with a custom, blow-molded plastic carrying case.
Description Manual tool for 12.5 oz. cartridges Manual tool for 30 oz. cartridges Battery-powered tool for 30 oz. cartridges Pneumatic tool for 30 oz. cartridges1, 2 AD30CKT battery AD30CKT charger
ADT30CKT
EDT14VCH
1. Air supply attachment is 14-18 NPT (male) thread. 2. Recommended operating air pressure is between 80120 psi.
ADTA30P
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Adhesive Accessories
Mixing Nozzles and Retaining Nuts
Mixing nozzles are designed for the proper proportioning and mixing of the different adhesive formulations. Use only appropriate Simpson Strong-Tie mixing nozzle in accordance with Simpson Strong-Tie instructions. Modication or improper use of the mixing nozzle may impair epoxy or acrylic performance. EMN22i An 18-element mixing nozzle for use with 22 oz. and 56 oz. epoxy adhesives cartridges. This is a one-piece nozzle with integrated nut (separate retaining nut not required). AMN19Q An 19-element, high-efciency static mixing nozzle for use with all acrylic adhesive products.
EMN22i
Adhesive Accessories
EMN37A An 18-element, high-strength, mixing nozzle for dispensing epoxy adhesive through bulk metering equipment. Description Mixing nozzle for 1.7 oz. cartridge (separate retaining nut not required). 18-element nozzle for 22 oz. and epoxy adhesive. Features an integrated threaded nut for attachment to cartridges. 18-element nozzle for dispensing epoxy through metering equipment Hi-volume nozzle for 22 oz., and 56 oz. cartridges (separate retaining nut not required), 17" long, major diameter 78" Five mixing nozzles for all AT products Model No. EMN1.7-R EMN22i EMN22i-RP5 EMN22i-RP10 EMN22iB EMN37A-RP5 Pkg Qty 2 1 5 10 5 Ctn Qty 24 Packs (2 nozzles per pack) 12 Nozzles 6 Packs (5 nozzles per pack) 3 Packs (10 nozzles per pack) 500 6 Packs (5 nozzles per pack) 10 10 Packs (5 nozzles per pack)
EMN37A
NEW
AMN19Q
EMN50 AMN19Q-RP5
Adhesive retaining caps make overhead and horizontal installation easier by preventing the adhesive from running out of the hole. They also center the rod in the hole, making them ideal for applications where precise anchor placement is required. It may be necessary to provide support for the insert during cure time. Adhesive retaining caps are not designed to support the weight of the insert in overhead installations. MATERIAL: Plastic
Pkg Qty 25 25 25 25 25 25 25
Ctn Qty* (ea) 200 200 200 200 200 200 200
Pkg Qty 25 25 25 25 25 25 25
Ctn Qty* (ea) 200 200 200 200 200 200 200
8 2 4
2 4
16 2 16 16 16 16
8 2 4
16 16 16 16
16 2 16 16 16 16
1 9 9
1 9 9
3 7
11
3 7
3 7
13
1 1 8
1
11 11
1 1 16
1
11 11
1 1 4
1
1 1 4
1
1 8
3
1 8
3
74
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Adhesive Accessories
Steel Adhesive-Anchoring Screen Tubes
Screen tubes are used in hollow base material applications to contain adhesive around the anchor and prevent it from running into voids. Simpson Strong-Tie screen tubes are specically designed to work with AT, SET and ET-HP adhesives in order to precisely control the amount of adhesive that passes through the mesh. This results in thorough coating and bonding of the rod to the screen tube and base material. Order screen tubes based upon rod diameter and adhesive type. The actual outside diameter of the screen tube is larger than the rod diameter. MATERIAL: Acrylic screen tubes: 50 mesh stainless steel; Epoxy screen tubes: 60 mesh carbon steel. Caution: Screen tubes are designed for a specic adhesive type. epoxy screen tubes must be used with SET or ET-HP formulations and acrylic screen tubes must be used with AT adhesive. Do not use SET1.7KTA with screen tubes.
Screen tubes are for use in hollow CMU, hollow brick and unreinforced masonry applications. Contact Simpson Strong-Tie for information on special order sizes.
Adhesive Accessories
Model No. ATS373 ATS376 ATS503 ATS506 ATS5010 ATS623 ATS626 ATS6210 ATS6213 ATS758 ATS7513 ATS7517
Model No. ETS376 ETS3710 ETS506 ETS5010 ETS626 ETS6210 ETS6213 ETS758 ETS7513 ETS7517 ETS7521
8 2
16 16
8 2
16 16
11
11
75
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Adhesive Accessories
Opti-Mesh Adhesive-Anchoring Screen Tubes
Screen tubes are vital to the performance of adhesive anchors in base materials that are hollow or contain voids, such as hollow block and brick. The Simpson Strong-Tie Opti-Mesh screen tube provides the economical advantage of a plastic screen tube while providing performance comparable to steel screen tubes and better than competitive plastic screen tubes. MATERIAL: Plastic
Integral Cap: Serves to center and secure the rod in the screen tube, while displaying important information such as rod diameter, drill bit diameter and the Simpson Strong-Tie "" sign for easy inspection after installation. The cap also prevents adhesive from running out of the front of the screen tube. Flanges: Prevents the screen tube from slipping into over-drilled holes. Allows screen tube to function in holes that are drilled too deep. Open-Mesh Collar: This section of larger mesh allows extra adhesive to ow out of the screen tube behind the face shell of hollow block applications. The extra "collar" of adhesive increases bearing area and results in higher load capacities in hollow concrete block. Color-Coded, Formula-Specic Mesh: The screen tube mesh is sized to allow only the right amount of adhesive to ow through the screen tube to bond with the base material while the balance remains in the screen to bond the rod. The acrylic screen tube mesh is white while the expoxy screen tube mesh is black.
U.S. Patent 6,837,018
Adhesive Accessories
Caution: Screen tubes are designed for a specic adhesive type. Epoxy screen tubes must be used with SET or ET-HP formulations and acrylic screen tubes must be used with AT adhesive. Do not use SET1.7KTA with screen tubes.
Load values for installations with SET are on page 30. Load values for installations with ET-HP in unreinforced masonry are on page 44. Not for use with SET1.7KTA.
Screen tubes are for use in hollow CMU, hollow brick and unreinforced masonry applications.
10 3 6 10 3 6 10 13 8 13 17 21
76
The photo on the left shows the Opti-Mesh screen tube installed in a hollow CMU block. The extra collar of adhesive created by the open-mesh collar results in increased bearing area and higher load values. The typical screen tube shown on the right relies on the bond between the relatively small amount of adhesive in contact with the face shell of the block for its holding power.
10 3 6 10 3 6 10 13 8 13 17 21
The integral cap centers the rod and displays drill bit and rod diameter.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Adhesive Accessories
Hole Cleaning Brushes
Brushes are used for cleaning drilled holes prior to adhesive anchor installation. Brushes have a twisted wire handle with nylon bristles. Description " dia x 3" brush (8" total length)
3 4" x 4" brush (16" total length)
Ctn Qty 24 24
ETB
1" x 4" brush (16" total length) 1" x 4" brush (24" total length) 114" x 4" brush (29" total length) 1 8" x 6" brush (34" total length
5
Adhesive Accessories
4" 4"
13
24 24 24 24
13
Description (in.)
13
Model No.
Drill Bit Threaded Rod For use with Carton Dia. Diameter Simpson Screen Qty. 1 (in.) (in.) Model No. 1
5
58
HEX NUT
16 x 8
1. Screens sold separately. Not for use with Simpson Strong-Tie screen #ETS758P or ATS758P plastic Opti-Mesh screen tubes.
Conguration C
Retrot Bolts
RFBs are pre-cut threaded rod, supplied with nut and washer. For use with Simpson Strong-Tie adhesives. May be ordered in bulk without the nut and washer. Use with Simpson Strong-Tie adhesives to anchor into existing concrete and masonry. Offers a complete engineered anchoring system when used with Simpson Strong-Tie anchoring adhesives. Each end of the threaded rod is stamped with rod length in inches and our No-Equal symbol for easy identification after installation. MATERIAL: ASTM F1554 Grade 36 FINISH: Zinc-plated, hot-dip galvanized Description Dia. Length 1 2" x 4" 1 2" x 5" 1 2" x 6" 1 2" x 7" 1 2" x 8" 1 2" x 10" 5 8" x 5" 5 8" x 8" 5 8" x 10" 5 8" x 12" 5 8" x 16" 3 4" x 10 12" Zinc Plated Model No. RFB#4x4 RFB#4x5 RFB#4x6 RFB#4x7 RFB#4x10 RFB#5x5 RFB#5x8 RFB#5x10 RFB#5x16 RFB#6x10.5 Hot-Dip Galvanized Model No. RFB#4x4HDG RFB#4x5HDG RFB#4x6HDG RFB#4x7HDG RFB#4x8HDG RFB#4x10HDG RFB#5x5HDG RFB#5x8HDG RFB#5x10HDG RFB#5x12HDG RFB#5x16HDG RFB#6x10.5HDG Ctn Qty 50 50 50 50 25 50 50 50 25 25 Bulk1 Qty 50 50 50 50 50 25 25 Retail2 Pack 10 10 10 10 10 10 10 10 10 10
1. Bulk quantities do not include the nut and washer and must be ordered with a -B sufx (example: RFB#4x5-B). Hot-dip galvanized RFBs not available in bulk. 2. Retail packs must be ordered with a -R sufx (example: RFB#5x12HDG-R).
77
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SOLUTION
Keep Material in heated storage area: Store epoxy at 4590F; Store Acrylic at 3280F. Remove nozzle, dispense small amount of material, then replace nozzle. Change to new nozzle or remove obstruction from cartridge outlet. Set air pressure at 80 - 100 psi. Remove coupling nut and reattach, taking care not to cross-thread. Do not attempt to dispense damaged cartridge. Regulate air pressure on pneumatic tool.
Adhesive Accessories
Excessive pressure resulting in swelling of cartridge or misalignment of retaining wiper. Misalignment of tool push rods and cartridge. Misalignment of cartridge.
Do not overdrive manual tool. See problem 1 to nd out why material is not owing. Adjust/repair dispensing tool. Make sure cartridge is inserted correctly. Regulate air pressure on pneumatic tool.
Excessive pressure.
Check to see mixing nozzle is not lled with gelled or hardened epoxy. Make sure one of the cartridges is not leaking out of the bottom (refer to problem 3).
Keep material in heated storage area: Store epoxy at 45 90F; Store acrylic at 32 80F. Abandon hole and drill new hole. If not possible, call Simpson Strong-Tie.
Make sure wipers on cartridge are equalized prior to dispensing and adhesive being dispensed is a uniform color before lling holes. Attach nozzle and dispense adhesive to the side until properly mixed (uniform color). Allow more time for epoxy to cure.
78
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Package Quantity 10 10 10 5 5
8" or #3 2" or #4
8" or #5 4" or #6
3 7
Vinylester Adhesive
8" or #7 1" or #8
Cure Schedule
Base Material Temperature F 25 32 50 68 C -4 0 10 20 Cure Time 5 hrs. 1 hr. 30 min. 20 min.
Tension Loads for Threaded Rod Anchors in Normal-Weight Concrete One (1) VGC Capsule Per Hole
Rod VGC Dia. Capsule in. (mm)
3 1
*
Tension Load Based on Bond Strength Tension Load Based on Steel Strength F1554 Grade 36 Allowable lbs. (kN) 2,105 (9.4) 3,750 (16.7) 5,875 (26.1) 8,460 (37.6) 11,500 (51.2) 15,025 (66.8)
*See page 13 for an explanation of the load table icons
Embed. Critical Critical Depth Edge Spacing in. Dist. Dist. (mm) in. in. (mm) (mm) 312 (88.9) 414 (108) 5 (127) 7 (178) 8 (203) 8 (203) 514 (133) 638 (162) 712 (191) 1012 (267) 1158 (295) 1312 (343) 14 (356) 17 (432) 20 (508) 28 (711) 32 (813) 32 (813)
(9.5) (12.7)
5
7 9
16 16 16
(15.9)
3 7
8 4
11
(19.1)
1 118
f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 5,585 504 1,395 (24.8) (2.2) (6.2) 9,653 546 2,410 (42.9) (2.4) (10.7) 4,265 (19.0) 21,605 2,643 5,400 (96.1) (11.8) (24.0) 7,310 (32.5) 29,236 3,263 7,310 (130.0) (14.5) (32.5)
f'c 4000 psi (27.6 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 6,875 692 1,720 (30.6) (3.1) (7.7) 10,800 1,494 2,700 (48.0) (6.6) (12.0) 17,048 1,345 4,265 (75.8) (6.0) (19.0) 26,598 2,087 6,650 (118.3) (9.3) (29.6) 30,837 1,174 7,709 (137.2) (5.2) (34.3) 38,205 3,166 9,550 (169.9) (14.1) (42.5)
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 4. Refer to allowable load-adjustment factors for spacing and edge distance on pages 8283. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 6. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure conditions.
79
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Shear Load Based on Steel Strength
*See page 13 for an explanation of the load table icons
Embed. Depth in. (mm) 312 (88.9) 414 (108) 5 (127) 7 (178) 8 (203) 8 (203)
Critical Edge Dist. in. (mm) 514 (133) 638 (162) 712 (191) 1012 (267) 1158 (295) 1312 (343)
Critical Spacing Dist. in. (mm) 514 (133) 638 (162) 712 (191) 1012 (267) 1158 (295) 1312 (343)
(9.5) (12.7)
5
7 9
16 16 16
(15.9)
3 7
8 4
11
(19.1)
Vinylester Adhesive
1 118
f'c 2000 psi F1554 F593 A193 GR B7 (13.8 MPa) Concrete Grade 36 304SS Ultimate Std. Dev. Allowable Allowable Allowable Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 5,581 311 1,395 1,085 2,340 1,870 (24.8) (1.4) (6.2) (4.8) (10.4) (8.3) 12,877 398 3,220 1,930 4,160 3,330 (57.3) (1.8) (14.3) (8.6) (18.5) (14.8) 18,702 675 4,675 3,025 6,520 5,220 (83.2) (3.0) (20.8) (13.5) (29.0) (23.2) 29,537 1,102 7,385 4,360 9,390 6,385 (131.4) (4.9) (32.9) (19.4) (41.8) (28.4) 33,676 1,274 8,420 5,925 12,770 8,685 (149.8) (5.7) (37.5) (26.4) (56.8) (38.6) 44,486 4,143 11,120 7,740 16,680 11,345 (197.9) (18.4) (49.5) (34.4) (74.2) (50.5)
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 4. Refer to allowable load-adjustment factors for spacing and edge distance on pages 8283. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
Tension Loads for Threaded Rod Anchors in Normal-Weight Concrete Two (2) VGC Capsules Per Hole
Rod VGC Dia. Capsule in. Two (2) (mm) Per Hole
3 1
*
Tension Load Based on Steel Strength
*See page 13 for an explanation of the load table icons
(9.5) (12.7)
5
7 9
16 16 16
(15.9)
3 7
8 4
11
1 118
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 4. Refer to allowable load-adjustment factors for spacing and edge distance on pages 8283. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 6. Anchors are not permitted to resist tension forces in wall installations unless proper consideration is given to fire-exposure conditions.
80
Embed. Critical Critical Depth Edge Spacing in. Dist. Dist. (mm) in. in. (mm) (mm)
f'c 2000 psi F1554 F593 A193 GR B7 (13.8 MPa) Concrete Grade 36 304SS Ultimate Std. Dev. Allowable Allowable Allowable Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 10,298 333 2,575 2,105 4,535 3,630 (45.8) (1.5) (11.5) (9.4) (20.2) (16.1) 18,530 134 4,635 3,750 8,080 6,470 (82.4) (0.6) (20.6) (16.7) (35.9) (28.8) 26,931 1,696 6,735 5,875 12,660 10,120 (119.8) (7.5) (30.0) (26.1) (56.3) (45.0) 47,469 1,731 11,865 8,460 18,230 12,400 (211.2) (7.7) (52.8) (37.6) (81.1) (55.2) 50,728 1,565 12,680 11,500 24,785 16,860 (225.6) (7.0) (56.4) (51.2) (110.2) (75.0) 72,128 3,089 18,030 15,025 32,380 22,020 (320.8) (13.7) (80.2) (66.8) (144.0) (97.9)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Tension Load Based on Steel Strength F1554 Grade 36 Allowable lbs. (kN) 5,875 (26.1) 11,500 (51.2)
d En "
Edge
134"
6"or 8"
W=
Tension Load Based on Bond Strength f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 13,250 1,590 3,310 (58.9) (7.1) (14.7) 20,843 1,883 5,210 (92.7) (8.4) (23.2)
(15.9)
7
VGC62 1 VGC100 2
11
16
(22.2)
12 (305) 15 (381)
6 (152) 8 (203)
5 (127) 5 (127)
1. Requires 3 capsules per hole. 2. Requires 2 capsules per hole. 3. Allowable load must be the lesser of the bond or steel strength. 4. The allowable loads listed under allowable bond are based on a safety factor of 4.0.
5. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 6. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
Edge and end distances for threaded rod in concrete foundation stemwall corner installation
Vinylester Adhesive
Tension Loads for Rebar Dowels in Normal-Weight Concrete One (1) VGC Capsule Per Hole
Rebar VGC Drill Embed. Critical Critical Size Capsule Bit Depth Edge Spacing No. Dia. in. Dist. Dist. (mm) in. (mm) in. in. (mm) (mm) #3 VGC37 (9.5) #4 VGC50 (12.7) #5 VGC62 (15.9) #6 VGC75 (19.1) #7 VGC100 (22.2) #8 VGC100 (25.4)
7
*
Tension Load Based on Steel Strength ASTM A615 Grade 60 Rebar Allowable lbs. (kN) 2,640 (11.7) 4,800 (21.4) 7,440 (33.1) 10,560 (47.0) 14,400 (64.1) 18,960 (84.3)
1. Allowable load must be the lesser of the bond or steel strength. 2. The allowable loads listed under allowable bond are based on a safety factor of 4.0. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 4. Refer to allowable load-adjustment factors for spacing and edge distance on pages 8283.. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions. 6. Anchors are not permitted to resist tension forces in overhead or wall installations unless proper consideration is given to fire-exposure conditions.
Tension Load Based on Bond Strength f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 6,211 480 1,555 (27.6) (1.8) (6.9) 14,579 1,365 3,645 (64.9) (6.1) (16.2) 12,066 3,904 3,015 (53.7) (17.4) (13.4) 18,692 2,225 4,675 (83.1) (9.9) (20.8) 33,182 548 8,295 (147.6) (2.4) (36.9) 34,517 5,163 8,630 (153.5) (23.0) (38.4)
16 8 4
3 7
1 118
514 (133) 638 (162) 712 (191) 1012 (267) 1158 (295) 1312 (343)
Shear Loads for Rebar Dowels in Normal-Weight Concrete One (1) VGC Capsule Per Hole
Rebar VGC Drill Embed. Critical Critical Size Capsule Bit Depth Edge Spacing No. Dia. in. Dist. Dist. (mm) in. (mm) in. in. (mm) (mm) #3 VGC37 (9.5) #4 VGC50 (12.7) #5 VGC62 (15.9) #6 VGC75 (19.1) #7 VGC100 (22.2) #8 VGC100 (25.4)
7
*
Shear Load Based on Steel Strength ASTM A615 Grade 60 Rebar Allowable lbs. (kN) 1,680 (7.5) 3,060 (13.6) 4,740 (21.1) 6,730 (29.9) 9,180 (40.8) 12,085 (53.8)
*See page 13 for an explanation of the load table icons
Shear Load Based on Concrete Edge Distance f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 8,294 515 2,075 (36.9) (2.3) (9.2) 11,012 383 2,755 (49.0) (1.7) (12.3) 15,758 1,154 3,940 (70.1) (5.1) (17.5) 23,314 1,494 5,830 (103.7) (6.6) (25.9) 32,662 5,588 8,165 (145.3) (24.9) (36.3) 8,165 (36.3)
16 8 4
3 7
1 118
514 (133) 638 (162) 712 (191) 1012 (267) 1158 (295) 1312 (343)
1. Allowable load must be the lesser of the load based on concrete edge distance or steel strength. 2. The allowable loads based on concrete edge distance are based on a safety factor of 4.0. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 4. Refer to allowable load-adjustment factors for spacing and edge distance on pages 8283. 5. Anchors are permitted to be used within fire-resistive construction, provided the anchors resist wind or seismic loads only. For use in fire-resistive construction, the anchors can also be permitted to be used to resist gravity loads, provided special consideration has been given to fire-exposure conditions.
81
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
1
Vinylester Adhesive
#3 312 514 134 0.65 0.65 0.68 0.78 0.88 0.98 1.00
8
7 1012 134 0.65 0.65 0.66 0.70 0.74 0.78 0.82 0.86 0.90 0.94 0.98 1.00
#4 414 638 134 0.65 0.65 0.67 0.74 0.82 0.90 0.97 1.00
2
812 1234 134 0.65 0.65 0.66 0.69 0.72 0.75 0.79 0.82 0.85 0.88 0.91 0.98 1.00
#5 5 712 134 0.57 0.57 0.59 0.66 0.74 0.81 0.89 0.96 1.00
8
10 15 134 0.61 0.61 0.62 0.65 0.68 0.71 0.74 0.76 0.79 0.82 0.85 0.91 0.97 1.00
#6 7 1012 134 0.54 0.54 0.55 0.61 0.66 0.71 0.76 0.82 0.87 0.92 0.97 1.00
4
14 21 134 0.56 0.56 0.57 0.59 0.61 0.63 0.66 0.68 0.70 0.73 0.75 0.79 0.84 0.89 0.93 0.98 1.00
#7 8 1158 134 0.54 0.54 0.55 0.60 0.64 0.69 0.74 0.78 0.83 0.88 0.92 1.00
8
16 24 134 0.52 0.52 0.53 0.55 0.57 0.59 0.61 0.63 0.65 0.68 0.70 0.74 0.78 0.83 0.87 0.91 0.96 1.00
1 #8 8 1312 134 0.54 0.54 0.55 0.59 0.63 0.67 0.71 0.75 0.78 0.82 0.86 0.94 1.00 16 24 134 0.39 0.39 0.40 0.42 0.45 0.48 0.51 0.53 0.56 0.59 0.62 0.67 0.73 0.78 0.84 0.89 0.95 1.00
*
1
312 514 134 0.35 0.35 0.40 0.58 0.77 0.95 1.00
414 638 134 0.15 0.15 0.20 0.38 0.56 0.75 0.93 1.00
#4 414 8 134 0.16 0.16 0.19 0.33 0.46 0.60 0.73 0.87 1.00
5 712 134 0.11 0.11 0.15 0.30 0.46 0.61 0.77 0.92 1.00
#5 5 10 134 0.10 0.10 0.13 0.24 0.35 0.45 0.56 0.67 0.78 0.89 1.00
7 1012 134 0.11 0.11 0.14 0.24 0.34 0.44 0.54 0.64 0.75 0.85 0.95 1.00
#6 7 12 134 0.10 0.10 0.12 0.21 0.30 0.39 0.47 0.56 0.65 0.74 0.82 1.00
1 #7 8 14 134 0.09 0.09 0.11 0.18 0.26 0.33 0.41 0.48 0.55 0.63 0.70 0.85 1.00 8 1312 134 0.08 0.08 0.10 0.18 0.26 0.33 0.41 0.49 0.57 0.65 0.73 0.88 1.00 #8 8 16 134 0.08 0.08 0.10 0.16 0.23 0.29 0.35 0.42 0.48 0.55 0.61 0.74 0.87 1.00
8 1158 134 0.08 0.08 0.10 0.20 0.29 0.38 0.48 0.57 0.66 0.76 0.85 1.00
82
1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. Ccr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual edge distance. 6. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
* 8
7 28 1214 312 0.58
1
Sact (in.)
134 2 3 4 6 8 10 14 18 22 26 30 35 40 45 50 55 60 65
See Notes Below
#3 312 14 618 134 0.58 0.58 0.60 0.68 0.76 0.92 0.95 0.96 1.00
2
812 34 1478 414 0.58
8
10 40 1712 5 0.58
4
14 56 2412 7 0.58
#7 8 32 14 4 0.58
8
16 64 28 8 0.58
1 #8 8 32 14 4 0.58 16 64 28 8 0.58
Vinylester Adhesive
0.61 0.66 0.72 0.83 0.93 0.94 0.96 0.97 0.98 1.00
0.60 0.64 0.72 0.80 0.88 0.93 0.94 0.95 0.96 0.98 0.99 1.00
0.58 0.65 0.72 0.79 0.93 0.95 0.96 0.98 0.99 1.00
0.58 0.62 0.69 0.76 0.83 0.90 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00
0.58 0.65 0.72 0.79 0.93 0.95 0.96 0.98 0.99 1.00
0.58 0.62 0.69 0.76 0.83 0.90 0.93 0.94 0.95 0.96 0.97 0.98 0.99 1.00
* 8
1
Sact (in.)
134 2 3 4 5 6 7 8 9 10 12 14
#3 312 514 134 0.83 0.83 0.84 0.89 0.94 0.99 1.00
#7 8 1158 4 0.83
1 #8 8 1312 4 0.83
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. Sint = intermediate spacing distance at which anchors are installed (inches). 6. fs = adjustment factor for allowable load at actual spacing distance. 7. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 8. fsmin = adjustment factor for allowable load at minimum spacing distance. 9. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
83
A proud, old hospital was crumbling. Since its construction in the early 1900s, the ravages of time and seismic activity had left hundreds of cracks that threatened to undermine the structural health of the facility. Utilizing crack repair adhesive systems from Simpson Strong-Tie helped to repair and contribute to the structural integrity of the building ultimately extending the life of the hospital. Simpson Strong-Tie offers reliable, easy-to-dispense products for a variety of restoration applications, including structural restoration, pick-proof sealing and water-intrusion prevention.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
ETI-LV
ETI-GV
ETI-SLV
Crack Injection
Caution The ETI-LV must be used with the Opti-Mix nozzle (EMN022) for proper mixing. ETI-GV may also be used with the EMN22i mixing nozzle for gravity feed applications in large cracks.
EMNO22 (included)
CLEAN UP: Removal of cured adhesive Chip or grind off surface. Uncured Adhesive Wipe up with cotton cloths. If desired, scrub area with abrasive, waterbased cleaner and ush with water. If approved, solvents such as ketones (MEK, acetone, etc.), lacquer thinner, or adhesive remover can be used. DO NOT USE SOLVENTS TO CLEAN ADHESIVE FROM SKIN. Take appropriate IMPORTANT See Pages 8889 for Installation Instructions precautions when handling ammable solvents. Solvents may damage surface to which they are applied. TEST ETI-SLV ETI-LV ETI-GV PROPERTY METHOD RESULTS RESULTS RESULTS TECHNICAL SPECIFICATIONS: Viscosity (75F) ASTM D 2393 350 cps 1,790 cps Non-sag gel ETI-SLV: Meets the requirements of ASTM C-881 3,100 psi 2,500 psi 1,109 psi Bond strength (moist cure) ASTM C 882 Type I, and IV, Grade 1, Classes B & C. (2 days) (2 days) (2 days) ETI-LV: Meets the requirements of ASTM C-881 3,900 psi 2,530 psi 3,994 psi Type I, II, IV and V, Grade 1, Classes B & C. (14 days) (14 days) (14 days) Approved under NSF/ANSI Standard 61 7,470 psi Tensile strength ASTM D 638 10,200 psi (22 in2/1000 gal). (7 days) Tensile elongation at break ASTM D 638 2.10% 9.4% ETI-GV: Meets the requirements of ASTM C-881 11,564 psi 12,480 psi Type I, II, IV and V, Grade 3, Classes B & C. Compressive yield strength ASTM D 695 16,500 psi (7 days) (7 days) CHEMICAL RESISTANCE: Very good to excellent Compressive modulus ASTM D 695 569,000 psi 342,000 psi 403,200 psi against distilled water, inorganic acids and alkalis. Deflection temperature ASTM D 648 140F 130F 131F Fair to good against organic acids and alkalis, and Water absorption (24 hrs) ASTM D 570 0.25% 0.76% 0.58% many organic solvents. Poor against ketones. Linear coefficient of shrinkage ASTM D 2566 0.0035 0.004 0.000 Accessories: See page 94 for information on Gel time (60 gram mass) ASTM D 881 16 min. 100 min. 135 min. mixing nozzles, parts, fittings and paste over material. Initial cure (72F) 24 hours 24 hours 24 hours
1. Bulk containers also available, call Simpson Strong-Tie for details. 2. Use only appropriate Simpson Strong-Tie mixing nozzle in accordance with Simpson Strong-Tie instructions. Modification or improper use of mixing nozzle may impair epoxy performance. 3. EDT22S tool needs to be configured for 2:1 cartridge ratio.
85
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Crack Injection
CHEMICAL RESISTANCE: Very good to excellent against distilled water, inorganic acids and alkalis. Fair to good against organic acids and alkalis, and many organic solvents. Poor against ketones.
Crack-Pac injection epoxy is also available in the Crack-Pac Injection Kit. The kit includes everything needed to pressure inject approximately 8 lineal feet of cracks: 2 Crack-Pac cartridge/nozzle sets 12 E-Z-Click injection ports 2 E-Z-Click injection fittings with 12" tubing 1 pint of paste-over epoxy (8 oz. of resin + 8 oz. of hardener) 4 disposable wood paste-over applicators 1 pair latex gloves Installation video
86
Accessories: See page 94 for information on mixing nozzles, parts, fittings and paste over material.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Cartridge Preparation and MiXing Instructions: Usage tip: After the product is mixed, a small volume of air will remain in the cartridge. Keeping this cushion of air at the back of the cartridge during dispensing will allow the dispensing of the final bit of epoxy from the nozzle once the cartridge is empty.
#1 on the valve aligns with the arrow on the neck of the nozzle.
Crack Injection
nozzle and allow the material contained within to drain into the cartridge.
and remove the black cap from the end of the nozzle. If performing gravity feed, the material is ready to dispense. If performing pressure injection, attach the E-Z-Click injection fitting to the end of the nozzle.
Warning: Do not mix product until ready to use within 30 minutes. A full cartridge of mixed epoxy will harden in 6575 minutes and will reach a peak temperature of 350F (177C) within two hours. To prevent pressure build up possibly resulting in cartridge breach and injury, remove cartridge from the caulking tool when not dispensing. Use caution handling or disposing of cartridge until cool.
87
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
1.1
Crack Injection
out gently on the head of the port to close it. Pulling too hard may dislodge the port from the surface of the concrete, causing a leak. Depress the metal tab on the head of the E-Z-Click fitting and remove it from the port. 5. Go to the last port where epoxy appeared while injecting the first port, open it, and continue injection at this port. If the epoxy has set up and the port is bonded closed, move to the next clean port and repeat the process until every portion of the crack has refused epoxy. While this method may appear to leave some ports uninjected, it provides maximum pressure to force the epoxy into the smaller areas of the crack. Moving to the next port as soon as epoxy appears will allow the epoxy to travel along the wider parts of the crack to the next ports rather than force it into the crack before it travels to the next ports. Injection Tips If using a pneumatic dispensing tool, set the tool at a low setting when beginning injection and increase pressure if necessary to get the epoxy to flow. For narrow cracks it may be necessary to increase the pressure gradually until the epoxy begins to flow. It may also be necessary to wait a few minutes for the epoxy to fill the crack and travel to the next port. If desired, once the injection epoxy has cured, remove the injection ports and paste-over epoxy. The epoxy can be removed with a chisel, scraper, or grinder. The past-over can be simply peeled off if CIP-F is used. Using a heat gun to soften the epoxy is recommended when using a chisel or scraper. Mixing nozzles can be used for multiple cartridges as long as the epoxy does not harden in the nozzle.
88
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Gravity-Feed Procedure
Crack Injection
Some horizontal applications where complete penetration is not a requirement can be repaired using the gravity feed method. 1. Follow cartridge preparation instructions on the cartridge label. Verify that the material flowing from the Opti-Mix mixing nozzle is a uniform black color for ETI-SLV and ETI-LV and a uniform gray color for ETI-GV. For Crack-Pac injection epoxy verify that the mixed material in the cartridge is a clear amber color. 2. Starting at one end of the crack, slowly dispense epoxy into the crack, moving along the crack as it fills. It will probably be necessary to do multiple passes in order to fill the crack. It is possible that the epoxy will take some time to run into the crack, and the crack may appear empty several hours after the initial application. Reapply the epoxy until the crack is filled. In situations where the crack completely penetrates the member (e.g. concrete slab) the material may continue to run through the crack into the subgrade. In these cases epoxy repair may not provide an effective repair. Tip: For narrow cracks, run a bead of caulk along each side of the crack approximately 18" from the edge of the crack. This will form a reservoir into which epoxy can be dispensed. Alternatively, use a grinder to route the crack opening into a V shape. Take care to clean the crack with compressed air afterwards as grinding can impact dust and debris into the crack and prevent proper flow of the epoxy.
64
32
Simpson Strong-Tie does not recommend repair of cracks larger than 14" wide without consulting a qualied engineer.
16
16
Coverage listed is approximate and will vary depending on waste and condition of concrete.
89
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Crack Injection
2 Crack-Pac Flex-H20 cartridge/nozzle sets 12 E-Z-Click injection ports 2 E-Z-Click injection fittings with 12" tubing
1 pint of paste-over epoxy (8 oz. of resin + 8 oz. of hardener) 4 disposable wood paste-over applicators 1 pair latex gloves
CHEMICAL RESISTANCE Very good to excellent against water, most hydrocarbons and alkalis. Poor to fair against ketones, chlorinated solvents and concentrated acids.
*CIP-F requires EIP-EZA port. See page 94 for information on Crack Repair Accessories.
90
DEFINITIONS: Dry Crack: A crack containing no moisture. Wet Crack: A crack containing moisture (damp or containing standing water). The surface can be dried and will remain dry during the paste-over operation. Seeping Crack: A wet crack that slowly oozes water. After being dried, the surface slowly becomes wet again. Mildly Leaking Crack: A crack with a slow trickle of water emitting from its face.
*For standard reaction time, use a 30:1 resin: catalyst ratio. For a faster reaction time, add more catalyst, for a slower reaction time, use less.
Accessories: See pages 94 for information on mixing nozzles, parts, fittings and paste over material. IMPORTANT See Pages 9193 for Installation Instructions
Crack-Pac Flex-H20 crack sealer is also available in the Crack-Pac Flex-H20 Injection Kit. The kit includes everything needed to pressure inject approximately 8 lineal feet of cracks:
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Cartridge Preparation and MiXing Instructions: Usage tip: After the product is mixed, a small volume of air will remain in the cartridge. Keeping this cushion of air at the back of the cartridge during dispensing will allow the dispensing of the final bit of epoxy from the nozzle once the cartridge is empty.
#1 on the valve aligns with the arrow on the neck of the nozzle.
Crack Injection
nozzle and allow the material contained within to drain into the cartridge.
Warning: Do not open cartridge until ready to use. The polyurethane will react to atmospheric moisture if left exposed. To prevent pressure build up possibly resulting in cartridge breach and injury, remove cartridge from the caulking tool when not dispensing. 8. Insert the cartridge into the caulking tool. 9. Turn the black valve to the #3
position and remove the black cap from the end of the nozzle. Attach the E-Z-Click injection fitting to the end of the nozzle for injection.
91
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Application Polyurethane injection is an effective and economical method of sealing cracks in concrete and solid masonry elements. Crack-Pac Flex-H20 crack sealer is suitable for sealing dry, wet, seeping and mildly leaking cracks in horizontal and vertical concrete and solid masonry elements ranging from 1 32" - 14". Denitions: Dry Cracka crack containing no moisture Wet Cracka crack containing moisture (damp or containing standing water). The surface can be dried and will remain dry during the paste-over operation. Seeping Cracka wet crack that slowly oozes water. After being dried, the surface slowly becomes wet again. Mildly Leaking Cracka crack with a slow trickle of water emitting from its face. NOTE: Multiple applications may be necessary to fill all voids.
Preparing the Crack for Injection Clean the crack and the surface surrounding it to allow the paste-up material to bond to sound concrete. At a minimum, the surface to receive paste-over should be brushed with a wire brush. Oil, grease or other surface contaminates must be removed in order to allow the paste-over to bond properly. Take care not to impact any debris into the crack during cleaning. With dry cracks, use clean, oil free compressed air to blow out as much dust and debris from the crack. For many applications, additional preparation is necessary in order to seal the crack. Where a surfacing material has been removed using an acid or chemical solvent, prepare the crack as follows: 1. Using clean, compressed air, blow out any remaining debris and liquid. 2. Remove residue by high-pressure washing or steam cleaning. 3. Blow any remaining water from the crack with clean compressed air. If a coating, sealant or paint has been applied to the concrete it must be removed before placing the paste-over material. Under the pressure of injection these materials may lift and cause a leak. If the surface coating is covering the crack, it may be necessary to route out the surface of the crack in a "V" shape using a grinder in order to get past the surface contamination.
Crack Injection
Dry or Wet Crack Application - Sealing of the crack and attachment of E-Z-Click ush mount injection ports (Model EIP-EZ or EIP-EZA) 1. To adhere the port to the concrete, apply a small amount of epoxy around the bottom of the port base. Place the port at one end of the crack and repeat until the entire crack is ported. As a rule of thumb, injection ports should be placed 8" apart along the length of the crack. Important: Do not allow epoxy to block the port or the crack under it, this is where adhesive must enter the crack. 2. Using a putty knife or other paste-over tool, generously work epoxy along the entire length of the crack. Take care to mound the epoxy around the base of ports and to work out any holes in the material. It is recommended that the paste-over should be a minimum of 18" thick and 1" wide. Insufficient paste-over will result in leaks under the pressure of injection. Allow the paste-over to cure before beginning injection. 3. For Dry Cracks- Crack-Pac Flex-H20 reacts with water and needs moisture present to cure. Therefore, if the crack to be sealed is completely dry, water must be introduced into it. Once ports are in place and the crack surface is pasted over, use a syringe or spray bottle to introduce approximately 1 ounce of water into each port. Note: CIP and CIP-F and ETR epoxies are a fast cure, manually mixed materials and may harden prematurely if left in a mixed mass on the mixing surface while installing ports. Spreading paste-over into a thin film (approximately 18") on the mixing surface will slow curing by allowing the heat from the reaction to dissipate.
Seeping Crack Application - Sealing of the crack and attachment of E-Z-Click ush mount injection ports (Model EIP-EZ) 1. Mix a small amount of quick-setting hydraulic cement with water in a container per manufacturer's recommendation (leave cement thick so it can be molded). Apply the cement generously to the top of the port ange and hold the port onto the concrete/masonry surface at one end of the crack until it sticks when the hand is released (usually about 1 minute). Repeat until the entire crack is sealed and ported. IMPORTANT: Be sure not to cover the port opening/closing interface with the cement. If this interface is covered, the cement must be cut away from this interface with a utility knife once it is cured, otherwise, the port will not close.
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1.1
2. To seal the remaining portions of the crack, mix small amounts of the hydraulic cement and apply it to the crack in a similar fashion. It is recommended that the paste-over be 316" thick and 1" wide. Once the entire crack is covered, all leaking water should be directed through the open ports. If water is leaking from any parts of the paste-over, be sure to patch these areas with additional hydraulic cement before injecting the crack. Mildly Leaking Crack Application - Sealing of the crack and attachment of E-Z-Click drill-in injection ports (Model EIPX-EZ) 1. Using a hammer drill or roto-hammer, drill 58" holes 34" deep at each end of the crack and along the crack approximately 8" apart. 2. Using the E-Z-Click Drilled-In port (model EIPX-EZ), gently pound the port into the drilled hole at the top of a vertical crack or at either end of a horizontal crack. Mix a small amount of quick-setting hydraulic cement with water in a container per manufacturer's recommendation (leave cement thick so it can be molded). 3. Apply the cement generously to the top of the port ange and hold until it sticks when the hand is released (usually about 1 minute). Repeat until the entire crack is sealed and ported. IMPORTANT: Be sure not to cover the port opening/closing interface with the cement. If this interface is covered, the cement must be cut away from this interface with a utility knife once it is cured, otherwise, the port will not close. 4. To seal the remaining portions of the crack, mix small amounts of the hydraulic cement and apply it to the crack in a similar fashion. Starting at one end and working toward the other. In vertical applications start at the top and work down. It is recommended that the paste-over be at least 316" thick and 1" wide. Once the entire crack is covered, all leaking water should be directed through the open ports. If water is leaking from any parts of the paste-over, be sure to patch these areas with additional hydraulic cement before injecting the crack.
92
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Injection Tips For narrow cracks it may be necessary to increase the pressure gradually until the polyurethane begins to ow. It may also be necessary to wait a few minutes for the material to fill the crack and travel to the next port. If desired, once the polyurethane has cured, remove the injection ports and paste-over epoxy or hydraulic cement. The paste-over can be removed with a chisel, scraper or grinder.
4. Inject polyurethane into the first port until material shows at the next port. Remove the E-Z-Click fitting by bracing the base of the port and pulling out gently on the head of the port to close it. Pulling too hard may dislodge the port from the surface of the concrete, causing a leak. Depress the metal tab on the head of the E-Z-Click fitting and remove it from the port. 5. Move to the next port and repeat until all ports have been injected.
Crack Injection
Troubleshooting Polyurethane is owing into the crack, but not showing up at the next port. This can indicate that either the crack expands and/or branches off under the surface of the concrete. Continue to inject and fill these voids. Back pressure is preventing polyurethane from owing. This can indicate several situations: The crack is not continuous and the portion being injected is full. The port is not aligned over the crack properly. The crack is blocked by debris. Polyurethane is leaking from the pasted-over crack or around injection ports. Stop injecting. If using a fast cure paste-over material (ETR or CIP), wipe off the leaking injection epoxy with a cotton cloth and re-apply the paste over material. Wait a approximately 1015 minutes to allow the paste-over to begin to harden. If the leak is large (e.g. the port broke off of the concrete surface) it is a good idea to wait approximately 30 minutes, or longer as necessary, to allow the paste-over to cure more completely. Check to see that the paste-over is hard before reinjecting or the paste-over or ports may leak. Another option for small leaks is to clean off the injection adhesive and use paraffin or crayon to seal the holes.
More polyurethane is being used than estimated. This may indicate that the crack either expands or branches off below the surface. Continue to inject and fill these voids. Less polyurethane is being used than estimated. This may indicate that the crack is shallower than originally thought, or the polyurethane is not penetrating the crack sufficiently before moving to the next port.
93
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
1. Use only appropriate Simpson Strong-Tie mixing nozzle in accordance with Simpson Strong-Tie instructions. Modification or improper use of mixing nozzle may impair paste over performance. 2. Each cartridge contains enough material to cover approximately 8 lineal feet of cracks. 3. CIPF22 can be dispensed without the mixing nozzle and mixed by hand using a mixing board and putty knife.
Crack Injection
CIP
Cure Time 3 hrs. 1 hr.
CIP-F
94
1. Use only an appropriate Simpson Strong-Tie mixing nozzle in accordance with Simpson Strong-Tie instructions. Modification or improper use of mixing nozzle may impair epoxy performance. 2. EIPX intended for use as a surface mount port in corners and a drilled-in port on flat surfaces. All accessories compatible with ETI-LV and ETI-GV epoxies.
Detailed information on the full line of Simpson Strong-Tie manual and pneumatic dispensing tools is available on pages 7273.
Mechanical Anchors
Simpson Strong-Tie mechanical anchors are designed to install easily and securely into a variety of base materials, including concrete, grouted and hollow CMU and brick. Speciers and contractors trust Simpson Strong-Tie anchors for optimum performance under the most demanding structural applications.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Installation Sequence
Mechanical Anchors
Finish: Zinc-plated (carbon steel) CODES: ICC-ES ESR-3037 (carbon and stainless steel in concrete); IAPMO ES ER-240 (carbon steel in CMU); City of Los Angeles RR25891; Underwriters Laboratories File Ex3605; Factory Mutual 3043442; Florida Pending TEST CRITERIA: The StrongBolt2 wedge anchor has been tested in accordance with the ICC-ES Acceptance Criteria for Mechanical Anchors in Concrete Elements (AC 193) and ACI 355.2 for the following: Static tension and shear loading in cracked and uncracked concrete Seismic and wind loading in cracked and uncracked concrete Performance in cracked concrete Performance in lightweight concrete over metal deck INSTALLATION: Do not use an impact wrench to set or tighten the Strong-Bolt 2 anchor. Caution: Oversized holes in the base material will make it difcult to set the anchor and will reduce the anchor's load capacity. Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified embedment depth and blow it clean using compressed air. Overhead installations need not be blown clean. Alternatively, drill the hole deep enough to accommodate minimum hole depth and dust from drilling. Assemble the anchor with nut and washer so that the top of the nut is flush with the top of the anchor. Place the anchor in the xture and drive into the hole until washer and nut are tight against the xture. Tighten to the required installation torque. DESIGN EXMPLE: See pages 233234
Length Identification Head Marks on Strong-Bolt 2 Wedge Anchors (corresponds to length of anchor inches)
Mark From Up To But Not Including Units in. in. A 112 2 B 2 212 C 212 3 D 3 312 E 312 4 F 4 412 G 412 5 H 5 512 I 512 6 J 6 612 K 612 7 L 7 712 M 712 8 N 8 812 O 812 9 P 9 Q R 11 S 11 12 T 12 13 U 13 14 V 14 15 W 15 16 X 16 17 Y 17 18 Z 18 19 912 10
912 10
96
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Material Specifications
Quantity Box 50 50 50 50 50 50 25 25 25 25 25 25 25 20 20 20 20 20 10 10 10 10 10 10 Carton 250 250 250 250 200 200 125 100 100 100 100 50 50 80 80 80 80 40 20 40 40 40 20 20
Carbon Steel Model No. STB2-37234 STB2-37300 STB2-37312 STB2-37334 STB2-37500 STB2-37700 STB2-50334 STB2-50414 STB2-50434 STB2-50512 STB2-50700 STB2-50812 STB2-50100 STB2-62412 STB2-62500 STB2-62600 STB2-62700 STB2-62812 STB2-62100 STB2-75512 STB2-75614 STB2-75700 STB2-75812 STB2-75100
316 Stainless Drill Bit Thread Steel Dia. Length Model No. (in.) (in.) STB2-372346SS STB2-373006SS STB2-373126SS STB2-373346SS STB2-375006SS STB2-377006SS STB2-503346SS STB2-504146SS STB2-504346SS STB2-505126SS STB2-507006SS STB2-508126SS STB2-501006SS STB2-624126SS STB2-625006SS STB2-626006SS STB2-627006SS STB2-628126SS STB2-621006SS STB2-755126SS STB2-756146SS STB2-757006SS STB2-758126SS STB2-751006SS 8 8 3 8 3 8 3 8 3 8 1 2 1 2 1 2 1 2 1 2 1 2 1 2 5 8 5 8 5 8 5 8 5 8 5 8 3 4 3 4 3 4 3 4 3 4
3 3
Carbon Steel - Zinc Plated 1 Component Materials Anchor Body Carbon Steel Nut Carbon Steel ASTM A 563, Grade A Washer Carbon Steel ASTM F844 Clip Carbon Steel ASTM A 568
1 16 1916 2116 2516 3916 5916 2116 2916 3116 31316 5516 6 6 2716 21516 31516 41516 6 6 3316 31516 41116 6 6
5
Type 316 Type 316 Type 316 Type 316 Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Mechanical Anchors
4 inch
3 4 3 4 7 8 150 3 5 4 5 6 7 8 1 6 2
Nominal Diameter Drill Bit Diameter Baseplate Clearance Hole Diameter2 Installation Torque Nominal Embedment Depth Effective Embedment Depth Minimum Hole Depth Minimum Overall Anchor Length Critical Edge Distance Minimum Edge Distance Minimum Spacing Minimum Concrete Thickness Yield Strength Tensile Strength Minimum Tensile and Shear Stress Area Axial Stiffness in Service Load Range Cracked and Uncracked Concrete
da3 d dc Tinst hnom hef hhole anch cac cmin for s smin for c hmin fya futa4 Ase
in. in. in. ft-lbf in. in. in. in. in. in. in. in. in. in. psi psi in2 lb./in
7 1 8 1 1 2 2 3 2 4 1 2 6
7 2 8 1 2 2 3 1 3 2 6
3 2 4 1 2 4 3 3 3 4 1 2 6 7 1 2 6 4
6 3
1 3 4 1 4 2
7
1 4 2
4
1 5 2
4 6 85,000
1 5 2
5
7 7 8 3 6 4
8 7 8
3 8 4
Additional Data
92,000 0.0514 34,820 115,000 0.105 63,570 70,000 110,000 0.270 118,840
0.166 91,370
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2. The clearance must comply with applicable code requirements for the connected element. 3. For the 2006 IBC, do replaces da. 4. For the 2003 IBC, fut replaces futa.
97
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
4 inch
3 3
Nominal Diameter Drill Bit Diameter Baseplate Clearance Hole Diameter2 Installation Torque Nominal Embedment Depth Effective Embedment Depth Minimum Hole Depth Minimum Overall Anchor Length Critical Edge Distance
da3 d dc Tinst hnom hef hhole anch cac cmin for s smin for c
in. in. in. ft-lbf in. in. in. in. in. in. in. in. in. in. 3 14 1 78 1 12 2 2 34 6 12
3 3
8 8
2 2
5 5
8 8 16
4 4 8
16
16
11
30 2 78 2 12 3 3 12 8 12 6 10 3 10 4 12 2 34 2 14 3 3 34 4 12 6 12 8 4 12
60 3 78 3 38 418 5 12 7 5 5 12 6 4 8 4 8 5 12 3 38 2 34 358 4 12 7 12
80 5 18 4 12 538 6 9 4 8 6 14 5 12 7 78 6 34 4 18 3 38 438 5 12 8
150 5 34 5 6 7 8 6 6 12 8 34
Minimum Spacing
Mechanical Anchors
hmin
Additional Data
Yield Strength Tensile Strength Minimum Tensile and Shear Stress Area Axial Stiffness in Service Load Range Cracked and Uncracked Concrete fya futa4 Ase psi psi in2 lb./in 80,000 100,000 0.0514 29,150 92,000 115,000 0.105 54,900 82,000 108,000 0.166 61,270 68,000 95,000 0.270 154,290
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2. The clearance must comply with applicable code requirements for the connected element. 3. For the 2006 IBC, do replaces da. 4. For the 2003 IBC, fut replaces futa.
98
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Nominal Anchor Diameter Carbon Steel 1 5 2 inch 8 inch
1
Symbol
1,2 or 3 hnom
Units
3
8 inch
278 234
4 inch
534
338
518
418
19,070
29,700
sa
in. in.
212 6
338 712
412 9
338 9 24 17 1.00
5 8
cb
N/A4 N/A4
6,8955 9,0255
N/A4 7,1155
8,5005 8,8705
Mechanical Anchors
p
Np,eq
eq
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The tabulated value of sa applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, the appropriate value of sa must be determined in accordance with ACI 318 D.4.5. StrongBolt 2 anchors are ductile steel elements as defined in ACI 318 D.1. 3. The tabulated value of cb applies when both the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4(c) for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be veried, the cb factors described in ACI 318 D.4.4 for Condition A are allowed. If the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4 for Condition A are met, the appropriate value of cb must be determined in accordance with ACI 318 D.4.4(c). If the load combinations of ACI 318 Appendix C are used, the appropriate value of cb must be determined in accordance with ACI 318 D.4.5(c). 4. N/A (Not Applicable) denotes that pullout resistance does not need to be considered. 5. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 2,500 psi)0.5. 6. The tabulated value of p or eq applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, appropriate value of must be determined in accordance with ACI 318 Section D.4.5(c). 7. For the 2003 IBC, 3 replaces c,N. 8. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength, Np,cr, Np,uncr and Neq by 0.6. All-lightweight concrete is beyond the scope of this table.
99
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Stainless Steel
Units
3
8 inch
2 inch
1
8 inch
4 inch
338
518
418
534
sa
hef cac kuncr kcr
212 812
338 7
412 9
338 8 24 17 1.00
5 8
c,N cb
p
Np,eq
Mechanical Anchors
eq
100
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The tabulated value of sa applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, the appropriate value of sa must be determined in accordance with ACI 318 D.4.5. StrongBolt 2 anchors are ductile steel elements as defined in ACI 318 D.1. 3. The tabulated value of cb applies when both the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4(c) for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be veried, the cb factors described in ACI 318 D.4.4 for Condition A are allowed. If the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4 for Condition A are met, the appropriate value of cb must be determined in accordance with ACI 318 D.4.4(c). If the load combinations of ACI 318 Appendix C are used, the appropriate value of cb must be determined in accordance with ACI 318 D.4.5(c). 4. N/A (Not Applicable) denotes that pullout resistance does not need to be considered. 5. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 2,500 psi)0.5. 6. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 2,500 psi)0.3. 7. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 2,500 psi)0.4. 8. The tabulated value of p or eq applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, appropriate value of must be determined in accordance with ACI 318 Section D.4.5(c). 9. For the 2003 IBC, 3 replaces c,N. 10. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength, Np,cr, Np,uncr and Neq by 0.6. All-lightweight concrete is beyond the scope of this table.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Units
3
2 inch
1 3 8
7
8 inch
518
4 inch
534
in. 1 8
7
2 4
3
338
418
sa
da5 e
in. in.
cb
kcp hef
0.70
cp
Steel Strength in Shear for Seismic Applications (ACI 318 Section D.3.3.3)
Vsa,eq lb 1,800 6,510 0.65 9,930 11,775
Mechanical Anchors
sa
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The tabulated value of sa applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, the appropriate value of sa must be determined in accordance with ACI 318 D.4.5. Strong-Bolt 2 anchors are ductile steel elements as defined in ACI 318 D.1. 3. The tabulated value of cb applies when both the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4(c) for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be veried, the cb factors described in ACI 318 Section D.4.4 for Condition A are allowed. If the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4 for Condition A are met, the appropriate value of cb must be determined in accordance with ACI 318 Section D.4.4(c). If the load combinations of ACI 318 Appendix C are used, the appropriate value of cb must be determined in accordance with ACI 318 Section D.4.5(c). 4. The tabulated value of cp applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, the appropriate value of cp must be determined in accordance with ACI 318 D.4.5(c). 5. For the 2006 IBC, do replaces da. 6. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength by 0.6. All-lightweight concrete is beyond the scope of this table.
101
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Symbol
1,2 or 3 hnom
Units
3
2 inch
1
8 inch
4 inch
in. 1 8
7
2 8
7
2 4
3
3 8
7
338
5 18
418
534
sa
da5 e
cb
kcp hef
0.70
2.0 2 2
1
1.0 2 4
1
2.0 3 8
3
2.0 2 4
3
2.0 4 2
1
3 8
3
cp
0.70
Steel Strength in Shear for Seismic Applications (ACI 318 Section D.3.3.3)
Vsa,eq lb 3,085 6,100 6,745 0.65 10,760 13,620
Mechanical Anchors
sa
102
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The tabulated value of sa applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, the appropriate value of sa must be determined in accordance with ACI 318 D.4.5. Strong-Bolt 2 anchors are ductile steel elements as defined in ACI 318 D.1. 3. The tabulated value of cb applies when both the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4(c) for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be veried, the cb factors described in ACI 318 Section D.4.4 for Condition A are allowed. If the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4 for Condition A are met, the appropriate value of cb must be determined in accordance with ACI 318 Section D.4.4(c). If the load combinations of ACI 318 Appendix C are used, the appropriate value of cb must be determined in accordance with ACI 318 Section D.4.5(c). 4. The tabulated value of cp applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, the appropriate value of cp must be determined in accordance with ACI 318 D.4.5(c). 5. For the 2006 IBC, do replaces da. 6. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength by 0.6. All-lightweight concrete is beyond the scope of this table.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 inch
3 38 3 30 2,6157 3,150
7
4 inch
Nominal Embedment Depth hnom Effective Embedment Depth hef Installation Torque Tinst Pullout Strength, concrete on metal deck (cracked)3,4 Np,deck,cr Pullout Strength, concrete on metal deck Np,deck,uncr (uncracked)3,4 Pullout Strength, concrete on metal deck (seismic)3,4 Np,deck,eq Steel Strength in Shear, concrete on metal deck5 Steel Strength in Shear, concrete on metal deck (seismic)5 Vsa,deck Vsa,deck,eq
2 1 58 1,0407 1,765
7
4 12 4 2,7307 3,840
7
3 38 2 34 90 2,6157 3,685
7
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. Prole steel deck must comply with the conguration in the gure below, and have a minimum base-steel thickness of 0.035 inch [20 gauge]. Steel must comply with ASTM A 653/A 653M SS Grade 33 with minimum yield strength of 33,000 psi. Concrete compressive strength shall be 3,000 psi minimum. 3. For anchors installed in the soft of sand-lightweight or normal-weight concrete over metal deck floor and roof assemblies, calculation of the concrete breakout strength may be omitted. 4. In accordance with ACI 318 Section D.5.3.2, the nominal pullout strength in cracked concrete for anchors installed in the soft of sand-lightweight or normal-weight concrete over metal deck floor and rood assemblies Np,deck,cr shall be substituted for Np,cr. Where analysis indicates no cracking at service loads, the normal pullout
strength in uncracked concrete Np,deck,uncr shall be substituted for Np,uncr. For seismic loads, Np,deck,eq shall be substituted for Np. 5. In accordance with ACI 318 Section D.6.1.2(c), the shear strength for anchors installed in the soffit of sand-lightweight or normal-weight concrete over metal deck floor and rood assemblies Vsa,deck shall be substituted for Vsa. For seismic loads, Vsa,deck,eq shall be substituted for Vsa. 6. The minimum anchor spacing along the flute must be the greater of 3.0hef or 1.5 times the flute width. 7. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 3,000 psi)0.5. 8. Concrete shall be normal-weight or structural sand-lightweight concrete having a minimum specied compressive strength, f'c, of 3,000 psi. 9. Minimum distance to edge of panel is 2hef.
Stainless Steel StrongBolt 2 Wedge Anchor Tension and Shear Strength Design Data for the Soffit of Concrete Over Profile Steel Deck Floor and Roof Assemblies1,2,6,10,11
Characteristic Symbol Units
3
Mechanical Anchors
8 inch
3 38 3 30 2,6058 3,950
8
4 inch
Nominal Embedment Depth hnom Effective Embedment Depth hef Installation Torque Tinst Pullout Strength, concrete on metal deck (cracked)3 Np,deck,cr Pullout Strength, concrete on metal deck Np,deck,uncr (uncracked)3 Pullout Strength, concrete on metal deck (seismic)5 Steel Strength in Shear, concrete on metal deck4 Steel Strength in Shear, concrete on metal deck (seismic)5 Np,deck,eq Vsa,deck Vsa,deck.eq
2 1 58 1,2308 1,580
8
4 12 4 2,5507 2,660
7
3 38 2 34 80 1,7509 2,470
7
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. Prole steel deck must comply with the conguration in the gure below, and have a minimum base-steel thickness of 0.035 inch [20 gauge]. Steel must comply with ASTM A 653/A 653M SS Grade 33 with minimum yield strength of 33,000 psi. Concrete compressive strength shall be 3,000 psi minimum. 3. For anchors installed in the soft of sand-lightweight or normal-weight concrete over metal deck floor and roof assemblies, calculation of the concrete breakout strength may be omitted. 4. In accordance with ACI 318 Section D.5.3.2, the nominal pullout strength in cracked concrete for anchors installed in the soft of sand-lightweight or normal-weight concrete over metal deck floor and rood assemblies Np,deck,cr shall be substituted for Np,cr. Where analysis indicates no cracking at service loads, the normal pullout strength in uncracked concrete Np,deck,uncr shall be substituted for Np,uncr. For seismic loads, Np,deck,eq shall be substituted for Np.
Min. 112" Min. 12" typ. Min. 3,000 psi normal or sand-lightweight concrete
5. In accordance with ACI 318 Section D.6.1.2(c), the shear strength for anchors installed in the soffit of sand-lightweight or normal-weight concrete over metal deck floor and rood assemblies Vsa,deck shall be substituted for Vsa. For seismic loads, Vsa, deck,eq shall be substituted for Vsa. 6. The minimum anchor spacing along the flute must be the greater of 3.0hef or 1.5 times the flute width. 7. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 3,000 psi)0.5. 8. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 3,000 psi)0.3. 9. The characteristic pull-out strength for greater concrete compressive strengths shall be increased by multiplying the tabular value by (f'c / 3,000 psi)0.4. 10. Concrete shall be normal-weight or structural sand-lightweight concrete having a minimum specied compressive strength, f'c, of 3,000 psi. 11. Minimum distance to edge of panel is 2hef.
Upper ute Max. 3" Min. 412" Min. 412" Min. 12" typ. Max. 1" offset, typ.
103
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
2 8 4
1. The tabulated allowable loads are based on a safety factor of 5.0 for installation under the IBC and IRC. 2. Listed loads may be applied to installations on the face of the CMU wall at least 114 inch away from headjoints. 3. Values for 8-inch wide concrete masonry units (CMU) with a minimum specied compressive strength of masonry, f'm, at 28 days is 1500 psi. 4. Embedment depth is measured from the outside face of the concrete masonry unit. 5. Tension and shear loads may be combined using the parabolic interaction equation (n = 5/3). 6. Refer to allowable load adjustment factors for edge distance and spacing on page 105.
Figure 1
4" minimum edge distance Critical edge distance (see load table) Installation in this area for reduced allowable load capacity
Mechanical Anchors
4" Minimum end distance Critical end distance (see load table) No installation within 1" of head joint
Carbon-Steel StrongBolt 2 Wedge Anchor Tension and Shear Loads in 8-inch Lightweight, Medium-weight and Normal-Weight Grout-Filled CMU
Size in. (mm) Drill Bit Dia. in. Min. Embed. Depth. in. (mm)
3 2 (89)
1
Tension Load
Shear Load Perp. To Edge Shear Load Parallel To Edge Allowable lbs. (kN)
235 (1.0) 275 (1.2)
35 (47.5) 55 (74.6)
12 (305) 12 (305)
8 (203) 8 (203)
438 (111)
1. The tabulated allowable loads are based on a safety factor of 5.0 for installation under the IBC and IRC. 2. Values for 8-inch wide concrete masonry units (CMU) with a minimum specied compressive strength of masonry, f'm, at 28 days is 1500 psi. 3. Tension and shear loads may be combined using the parabolic interaction equation (n = 5/3). 4. Refer to allowable load adjustment factors for edge distance and spacing on page 105.
Figure 2
134" Edge
104
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 4 38 20 4 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
5
4 5 14 20 4 0.97 0.97 0.97 0.98 0.98 0.99 0.99 0.99 1.00 1.00
3
8 4 38 20 4 0.36 0.36 0.44 0.52 0.60 0.68 0.76 0.84 0.92 1.00
5
4 5 14 20 4 0.28 0.28 0.37 0.46 0.55 0.64 0.73 0.82 0.91 1.00
3
Mechanical Anchors
Load Adjustment Factors for Carbon-Steel StrongBolt 2 Anchors in Top-of-Wall Installation in 8" Grout-Filled CMU: Edge Distance and Spacing, Tension and Shear Loads
How to use these charts: 5. The load adjustment factor (fc or fs) is the intersection of the row and column. 1. The following tables are for reduced edge distance and spacing. 2. Locate the anchor size to be used for either a tension and/or shear load application. 6. Multiply the allowable load by the applicable load adjustment factor. 7. Reduction factors for multiple edges or spacings are multiplied together. 3. Locate the embedment (E) at which the anchor is to be installed. 4. Located the edge distance (Cact) or spacing (Sact) at which the anchor is to be installed.
* End Distance
Cact (in.)
4 6 8 10 12
page 13 for an * * See explanation of the load table icons
105
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Strong-BoLt for Cracked and Uncracked Concrete Strong-Bolt Wedge Wedge Anchor Anchor for Cracked and Uncracked Concrete
IBC
2009
ESR-1771
The StrongBolt is a wedge anchor specically designed for optimum performance in both cracked and uncracked concrete; a requirement that the 2009 IBC places on post-installed anchors. Rigorously tested according to the latest industry-wide criteria, the Strong-Bolt anchor is proven to offer increased reliability in the most adverse conditions, including performance in cracked concrete under static and seismic loading. The proprietary tri-segmented clip has dual undercutting embossments on each segment which enable secondary or "follow-up" expansion if a crack forms and intersects the anchor location. This signicantly increases the ability of the Strong-Bolt wedge anchor to carry load if the hole opened slightly due to a crack. The Strong-Bolt anchor sets like a standard wedge anchor and is available in Imperial fractional sizes.
FEATURES: Tri-segmented clip: Each segment is able to adjust independently increasing follow-up expansion should the hole increase in size as a result of a crack. Dual embossments on each clip segment: Allows the clip to undercut into the concrete increasing follow-up expansion should a crack occur. 316 stainless steel clip: In addition to superior corrosion resistance, a stainless steel clip offers better "memory". This memory contributes to the anchors performance should the hole size increase due to a crack. Imperial fractional sized anchor: Fits most fixtures and installs with common drill bits sizes and tools. No need to buy additional tools to install a metric anchor and no special couplers needed. Installs like a standard wedge anchor: No complicated installation procedure. No need for special bits or installation tools. The head is stamped with the Simpson Strong-Tie "" sign and size ID for easy post-installation identication MATERIAL: Carbon-steel stud with 316 stainless-steel clip FINISH: Zinc plated CODES: ICC-ES ESR-1771; City of L.A. RR25705; Florida FL 11506.6 The load tables list values based upon results from the most recent testing and may not reflect those in current code reports. Where code jurisdictions apply, consult the current reports for applicable load values.
Tri-Segmented Clip
Mechanical Anchors
TEST CRITERIA: The Strong-Bolt wedge anchor has been tested in accordance with the ICC-ES Acceptance Criteria for Mechanical Anchors in Concrete Elements (AC193) and ACI 355.2 for the following: Static tension and shear loading in cracked and uncracked concrete Seismic and wind loading in cracked and uncracked concrete Performance in cracked concrete Vibratory Load Testing: A 150 lb. concrete block was suspended from a 12" diameter anchor embedded at 214" and vibrated for 12.6 million cycles at a frequency of 30 Hz and an amplitude of 0.025 inches. Subsequent load test showed no reduction in ultimate tension capacity. INSTALLATION: Do not use an impact wrench to set or tighten the Strong-Bolt anchor. Caution: Oversized holes in the base material will make it difcult to set the anchor and will reduce the anchor's load capacity. Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified embedment depth and blow it clean using compressed air. Overhead installations need not be blown clean. Alternatively, drill the hole deep enough to accommodate minimum hole depth and dust from drilling. Assemble the anchor with nut and washer so that the top of the nut is flush with the top of the anchor. Place the anchor in the xture and drive into the hole until washer and nut are tight against the xture. Tighten to the required installation torque. APPLICATION: Interior environment where low levels of moisture and corrosive chemicals are present. SUGGESTED SPECIFICATIONS: Wedge anchors shall be an imperial-sized steel threaded stud with an integral cone expander and a three-segment expansion clip. The stud shall be manufactured from carbon steel and the expansion clip shall have two undercutting embossments per segment and be manufactured from 316 stainless steel. The anchor shall have been tested and qualied for performance in cracked concrete per ACI 355.2 and ICC-ES AC193. Anchors shall be StrongBolt wedge anchors from Simpson Strong-Tie, Pleasanton, CA, and be installed following Simpson Strong-Tie instructions.
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1 1 118 112
1 9
2 16 3 4
11
8 16 15 16
5
3 7
118
4 8
Length Identification Head Marks on Strong-Bolt Anchors (corresponds to length of anchor inches).
Mark A B C D E F G H I J K L M N O P Q R S 11 12 T 12 13 U 13 14 V 14 15 W 15 16 X 16 17 Y 17 18 Z 18 19 From 112 2 212 3 312 4 412 5 512 6 612 7 712 8 812 9 912 10 Up to but not 2 212 3 312 4 412 5 512 6 612 7 712 8 812 9 912 10 11 including
106
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Strong-BoLt for Cracked and Uncracked Concrete Strong-Bolt Wedge Wedge Anchor Anchor for Cracked and Uncracked Concrete
Material Specifications
Quantity Box 25 25 25 25 25 25 20 20 20 20 20 10 10 10 10 10 10 5 5 5 Carton 125 100 100 100 50 50 80 80 80 80 40 20 40 40 40 20 20 20 10 10 Anchor Body Carbon Steel - Zinc Plated 1 Component Materials Nut Washer Clip
Model No. STB50334 STB50414 STB50512 STB50700 STB50812 STB50100 STB62412 STB62500 STB62600 STB62700 STB62812 STB62100 STB75512 STB75614 STB75700 STB75812 STB75100 STB100700 STB1001000 STB1001300
Drill Bit Thread Dia. Length (in.) (in.) 134 214 312 5 6 6 2116 2916 3916 4916 6 6 21116 3716 4316 51116 6 312 312 312
Thread length
Carbon Steel Carbon Carbon 316 SAE J403, Steel Steel Stainless Grade 1030-1035 ASTM A 563, ASTM F844 Steel Grade A SAE J403, Grade 12L14
1. Zinc meets ASTM B 633, Class SC 1 (Fe / Zn 5), Type III.
1. The published length is the overall length of the anchor. 2. Allow one anchor diameter for the nut and washer thickness plus the fixture thickness when selecting a length.
Mechanical Anchors
Installation Information
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1 9
2 2
8 8 16
618 814 418 1312
4 4
3 7
16
5 634 338 11
11
234 9
50 378 778 4 4 6
85 518 958 5 6 4
1
934 1312
6 4
3
5 2
1
7 8
7
8 4
1
6 4
3
8 4
3
1312
Additional Data 1 108,000 125,000 0.108 125,000 0.167 141,000 0.273 225,000
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D.
107
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
378 5 338 518 Steel Strength in Tension 13,500 20,875 0.75 2 0.75 2
618
418
36,815 0.65 2
Concrete Breakout Strength in Tension9 in. in. 0.65 8 Pullout Strength in Tension10 Np,uncr Np,cr lb lb 3 3 4,120 5 4,600 5 2,995 5 2,995 5 0.65 6 0.65 6 3 3 7,250 4 7,300 4 5,200 4 5,260 4 0.65 6 0.65 6 3 3 9,420 5 12,115 5 8,360 5 9,690 5 3 0.55 6 9,850 5 0.55 6 7,7005 11,185 5 0.55 6 0.55 6 2.250 9 3.375 7 8
7
4.500 6 4
3
2.750 11
4.500 9 8
5
5.500 8 4
1
3.375 13 2
1
5.000 11 4
3
6.750 10 8
1
4.500 18
9.000 1312
24 17 1.00 0.55 8
c,N
Mechanical Anchors
Pullout Strength in Tension for Seismic Applications10 Np,eq lb 3 2,995 5 2,995 5 0.65 6 0.65 6 3 5,200 4 5,260 4 0.65 6 0.65 6 3 3 9,850 5 0.55 6 7,7005 11,185 5 0.55 6 0.55 6
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . The 34 inch and 1 inch diameter are considered as a brittle steel element. The 12 inch and 58 inch diameters are considered as ductile steel elements. 3. Pullout strength is not reported since concrete breakout controls. 4. Adjust the characteristic pullout resistance for other concrete compressive strengths by multiplying the tabular value by (f'c,specified / 2,500) 0.7. 5. Adjust the characteristic pullout resistance for other concrete compressive strengths by multiplying the tabular value by (f'c,specified / 2,500) 0.5. 6. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met.If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 7. The modification factor cp,N = 1.0 for cracked concrete. Otherwise,the modification actor for uncracked concrete without supplementary reinforcement to control splitting is either: (2) cp,N = C C if ca,min < cac. ac ac The modification factor, cp,N is applied to the nominal concrete breakout strength, Ncb or Ncbg. or (1) cp,N = 1.0 if ca,min cac
Ca,min 1.5hef
8. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition A are met, refer to Section D4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 9. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength by 0.60. All-lightweight concrete is beyond the scope of this table. 10. For sand-lightweight concrete, modify the value of Np,cr, Np,uncr and Neq by 0.60. All-lightweight concrete is beyond the scope of this table.
108
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
618
418
do
Concrete Breakout Strength in Shear5 0.5 0.625 2.25 3.375 4.00 2.75 4.50 5.00 0.70 3 3.375
5.00
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . The 34 inch and 1 inch diameter are considered as a brittle steel element. The 12 inch and 58 inch diameters are considered as ductile steel elements. 3. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition A are met, refer to Section D4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of .
4. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 5. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength by 0.60. All-lightweight concrete is beyond the scope of this table.
Mechanical Anchors
109
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
The Titen HD anchor is a patented, high-strength screw anchor for concrete and masonry. It is designed for optimum performance in both cracked and uncracked concrete; a requirement that the 2009 IBC places on post-installed anchors. The high strength, easy to install Titen HD anchor has been tested and shown to provide outstanding performance in cracked and uncracked concrete under both static and seismic loading conditions. The self-undercutting, non-expansion characteristics of the Titen HD anchor make it ideal for structural applications, even at reduced edge distances and spacings. Recommended for permanent dry, interior non-corrosive environments or temporary outdoor applications. PERFORMANCE FEATURES: Tested per AC193 to ensure outstanding performance in both cracked and uncracked concrete Higher load capacity and vibration resistance: Threads along the length of the anchor undercut the concrete and efciently transfer the load to the base material. Vibration and shock resistance: The mechanical interlock of the threads and the ratchet teeth on the underside of the head help prevent the anchor from loosening in vibratory conditions. The Titen HD anchor has been tested to 12.6 million vibratory cycles with no performance reductions. Specialized heat treating process: Creates superior surface hardness at the tip to facilitate cutting, while at the same time not compromising ductility within the anchor body. Less spacing and edge distance required: The anchor does not exert expansion forces on the base material. Easy post-installation inspection: The head is stamped with the Simpson Strong-Tie "" sign and the anchor length in inches. INSTALLATION FEATURES: No special drill bit needed: Designed to install using standard sized ANSI tolerance drill bits Installs with 50% less torque: Testing shows that when compared to competitors, the Titen HD requires 50% less torque to be installed in concrete. Hex-washer head: Requires no separate washer and provides a clean installed appearance.* Removable: Ideal for temporary anchoring (e.g. formwork, bracing) or applications where fixtures may need to be moved. Re-use of the anchor to achieve listed load values is not recommended. See reinstallation note on next page. MATERIAL: Carbon steel, heat treated
IBC
2009
ESR-2713
Serrated teeth on the tip of the Titen HD screw anchor facilitate cutting and reduce installation torque.
Mechanical Anchors
FINISH: Zinc plated or mechanically galvanized CODES: ICC-ES ESR-2713 (concrete); ICC-ES ESR-1056 (CMU); City of L.A. RR25741(concrete)City of L.A. RR25560(CMU); Florida FL 11506.7; Factory Mutual 3017082, 3035761 and 3043442. The load tables list values based upon results from the most recent testing and may not reflect those in current code reports. Where code jurisdictions apply, consult the current reports for applicable load values.
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
TEST CRITERIA: The Titen HD anchor has been tested in accordance with ICC-ES AC193, ACI 355.2 and ICC-ES AC106 for the following: Static tension and shear loading in cracked and uncracked concrete Seismic and wind loading in cracked and uncracked concrete Performance in uncracked masonry Anchor Fatigue Testing: Tested in accordance with ASTM E 488 for the effects of fatigue. 25% of the average ultimate load was applied to the anchor for 2 million cycles at a frequency of 15 Hz. Subsequent load tests showed no reduction in ultimate tension capacity. Vibratory Load Testing: A 150 lb. concrete block was suspended from a 38" diameter anchor embedded at 112" and vibrated for 12.6 million cycles at a frequency of 30 Hz and an amplitude of 0.0325 inches. Subsequent load test showed no reduction in ultimate tension capacity. Field Testing: For guidance on field testing see technical bulletin T-SAS-THDINSP. INSTALLATION: Holes in metal xtures to be mounted should match the diameter specied in the table on the next page. Caution: Oversized holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. Use a Titen HD screw anchor one time only. Installing the anchor multiple times may result in excessive thread wear and reduce load capacity. Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified embedment depth plus 1 2" minimum to allow the thread tapping dust to settle and blow it clean using compressed air. Overhead installations need not be blown clean. Alternatively, drill the hole deep enough to accommodate embedment depth and dust from drilling and tapping. Insert the anchor through the xture and into the hole. Tighten the anchor into the base material until the hex washer head contacts the xture. Do not use impact wrenches to install into hollow CMU. SUGGESTED SPECIFICATIONS: Screw anchors shall have 360-degree contact with the base material and shall not require oversized holes for installation. Fasteners shall be manufactured from carbon steel, and are heat-treated. Anchors shall be zinc plated in accordance with ASTM B633 or mechanically galvanized in accordance with ASTM B695. Anchors are not to be reused after initial installation. Screw anchors shall be Titen HD anchors from Simpson Strong-Tie, Pleasanton, CA. Anchors shall be installed per the Simpson Strong-Tie instructions for the Titen HD anchor. *Some jurisdictions require an additional square plate washer for sill plate applications.
Longer 12" diameter Titen HD anchors achieve sufficient embedment depth to develop tension loads equal to many Simpson Strong-Tie holdowns that specify a 58 " diameter anchor. Testing has been conducted to assure compatibility of these holdowns anchor holes with the 12" Titen HD screw anchor.
Installation Sequence
110
2" min.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
Titen HD Anchor Product Data - Zinc Plated
Size (in.) 8 x 3 8 x 4 3 8 x 5 3 8 x 6 1 2 x 3 1 2 x 4 1 2 x 5 1 2 x 6 1 2 x 612 1 2 x 8 1 2 x 12 1 2 x 13 1 2 x 14 1 2 x 15 5 8 x 4 5 8 x 5 5 8 x 6 5 8 x 612 5 8 x 8 5 8 x 4 5 8 x 5 5 8 x 6 5 8 x 612 5 8 x 8 3 4 x 4 3 4 x 5 3 4 x 6 3 4 x 7 3 4 x 812 3 4 x 10
3 3
Model No. THD37300H THD37400H THD37500H THD37600H THD50300H THD50400H THD50500H THD50600H THD50612H THD50800H THD501200H THD501300H THD501400H THD501500H THD62400H THD62500H THD62600H THD62612H THD62800H THDB62400H THDB62500H THDB62600H THDB62612H THDB62800H THD75400H THD75500H THDT75600H THD75700H THD75812H THD75100H
Model No. THD37500HMG THD37600HMG THD50500HMG THD50600HMG THD50612HMG THD50800HMG THD62500HMG THD62600HMG THD62612HMG THD62800HMG THDB62500HMG THDB62600HMG THDB62612HMG THDB62800HMG THD75812HMG THD75100HMG
16
8 2
16 4
15
16
8 4
15
16
15
16
118
15
16
1. Mechanical galvanizing meets ASTM B695, Class 65, Type 1. Intended for some pressure-treated wood sill plate applications. Not for use in other corrosive or outdoor environments. See page 11 or visit www.strongtie.com/info for more corrosion information.
118
1. Zinc plating meets ASTM B633, SC1. 2. Length is measured from the underside of the head to the tip of the anchor.
The Titen HD screw anchor 34" x 6" and 34" x 7" (models THDT75600H and THD75700H) have a 1" section under the head that is unthreaded to allow installation into tilt-up wall braces.
Mechanical Anchors
FIXTURE HOLE DIAMETER: Due to the full shank diameter and larger threads of the Titen HD screw anchor, consideration needs to be given to specifying the appropriate diameter Titen HD anchor based on the xture hole type to be used. The American Institute of Steel Construction (AISC) has established the following guidelines with regards to xture hole sizing depending on the hole type: Standard fixture holes are 116" larger than the nominal anchor diameter. Oversized fixture holes are 18 -316" larger than the nominal anchor diameter, depending upon the specic anchor diameter.
ANCHOR
ANCHOR
Hole Dimensions
Titen HD Wrench Recommended Diameter Size Fixture (in.) (in.) Hole Size (in.)
3
8 2
16 4
to to to to
16 16
8 4
11
1 16
" LARGER
FIXTURE
LARGER
8" 316"
FIXTURE
8 4
15
16
13
16 16
118
15
Use the following table to identify which diameter Titen HD screw anchor to use based on the xture hole type and diameter. In most cases where a smaller diameter Titen HD anchor is called out in comparison to the competitor's larger diameter anchor, the Titen HD anchor still generally provides allowable tension and shear load values comparable to or greater than those of the competitor's anchor.
111
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
Titen HD Anchor Installation Information and Additional Data1
Characteristic Symbol Units Nominal Anchor Diameter (in.)
38
3 1
2 2
584
5 3
4 4
Installation Information Drill Bit Diameter Baseplate Clearance Hole Diameter Maximum Installation Torque Maximum Impact Wrench Torque Rating Embedment Depth Critical Edge Distance Minimum Edge Distance Minimum Spacing Minimum Concrete Thickness Anchor Category Yield Strength Tensile Strength Minimum Tensile & Shear Stress Area Axial Stiffness in Service Load Range - Uncracked Concrete Axial Stiffness in Service Load Range - Cracked Concrete dbit dc Tinst,max Timpact,max hnom cac cmin smin hmin in. in. ft-lb ft-lb in. in. in. in. in. Additional Data category fya futa Ase psi psi in2 lb/in. lb/in. 0.099 0.183 715,000 345,000 1 97,000 110,000 0.276 0.414 334 5 5 614 212 2 16
11
3 7
652 3403
314 3 16
9
1002 3403 4 4 2
1
4 4 2
1
512 6 8
3
614 7516
uncr cr
Mechanical Anchors
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2. Tinst,max is the maximum permitted installation torque for the embedment depth range covered by this table for installations using a torque wrench. This is not applicable to other embedment depths published elsewhere in this catalog.
3. Timpact,max is the maximum permitted torque rating for impact wrenches for the embedment depth range covered by this table. This is not applicable to other embedment depths published elsewhere in this catalog. 4. Data for 58" anchor is only valid for THDB62 series.
112
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
Titen HD Anchor Tension Strength Design Data1
Characteristic Embedment Depth Tension Resistance of Steel Strength Reduction Factor - Steel Failure Effective Embedment Depth Critical Edge Distance6 Effectiveness Factor - Uncracked Concrete Effectiveness Factor - Cracked Concrete Modification Factor Strength Reduction Factor - Concrete Breakout Failure Pullout Resistance, Uncracked Concrete (f'c=2,500 psi) Pullout Resistance, Cracked Concrete (f'c=2,500 psi) Strength Reduction Factor - Pullout Failure Nominal Pullout Strength for Seismic Loads (f'c=2,500 psi) Strength Reduction Factor - Breakout or Pullout Failure Symbol hnom Nsa hef cac kuncr kcr Units in. lb. in. in. lb. lb. lb. 1,2354 2,7004 3 3 2,7004 1,2354 3 2,7004 3 3 3 3 0.65
5
38
2 2
1
2
4 4
589
5 2
1
4
614
3 4
1
3 4
1
5 2
1
Steel Strength in Tension 10,890 20,130 0.65 1.77 21116 2.40 358 2.35 3916 2.99 412 24 17 1.0 0.657 3 32604 9810 55704 3 6,0704 3 7,1954
2
30,360
45,540
Concrete Breakout Strength in Tension6,8 2.97 412 4.24 638 4.22 638 4.86 7516
c,N
Np,uncr Np,cr
Np,eq
55704
6,0704
7,1954
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . Anchors are considered brittle steel elements. 3. Pullout strength is not reported since concrete breakout controls. 4. Adjust the characteristic pullout resistance for other concrete compressive strengths by multiplying the tabular value by (f'c,specified / 2,500) 0.5. 5. T he value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 6. The modification factor cp,N = 1.0 for cracked concrete. Otherwise, the modification factor for uncracked concrete without supplementary reinforcement to control splitting is either: (1) cp,N = 1.0 if ca,min cac or (2) cp,N = C C if ca,min < cac. The modification factor, ac ac cp,N is applied to the nominal concrete breakout strength, Ncb or Ncbg.
Ca,min 1.5hef
Mechanical Anchors
113
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
Titen HD Anchor Shear Strength Design Data1
Characteristic Embedment Depth Shear Resistance of Steel Strength Reduction Factor - Steel Failure Outside Diameter Load Bearing Length of Anchor in Shear Strength Reduction Factor Concrete Breakout Failure Coefficient for Pryout Strength Strength Reduction Factor - Concrete Pryout Failure Shear Resistance of Single Anchor for Seismic Loads Strength Reduction Factor - Steel Failure Symbol hnom Vsa Units in. lb. Concrete Breakout Strength in Shear6 do in. in. Concrete Pryout Strength in Shear kcp Steel Strength in Shear for Seismic Applications Veq lb. 2,855 4,790 0.602
4. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . 5. Data for 58" anchor is only valid for THDB62 series. 6. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength by 0.6. All-lightweight concrete is beyond the scope of this table.
*
Nominal Anchor Diameter (in.)
3
8
3 4
1
2
4 4
5 5 8
4
614
2 2
1
3 4
1
5 2
1
5 2
1
Steel Strength in Shear 4,460 7,455 0.602 0.375 1.77 2.40 2.35 0.500 2.99 0.703 2.97 0.625 4.24 4.22 0.750 4.86 10,000 16,840
1.0 0.70
4
2.0
8,000
9,350
Mechanical Anchors
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of . Anchors are considered brittle steel elements 3. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D4.4(c) for Condition A are met, refer to Section D4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D4.5 to determine the appropriate value of .
Lower Flute Characteristic Embedment Depth Effective Embedment Depth Pullout Resistance, concrete on metal deck (cracked)3,4 Pullout Resistance, concrete on metal deck (uncracked)3,4 Steel Strength in Shear, concrete on metal deck5 Steel Strength in Shear, Seismic Symbol hnom hef Np,deck,cr Np,deck,uncr Vsa,deck Vsa, deck, eq Units in. in. lbs. lbs. lbs. lbs. Nominal Anchor Diameter (inch)
3
8
2 2
1
2
3 2
1
8
7
1 8
7
114
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. Concrete compressive strength shall be 3,000 psi minimum. The characteristic pullout resistance for greater compressive strengths shall be increased by multiplying the tabular value by (f'c,specified / 3,000 psi)1/2. 3. For anchors installed in the soffit of sand-lightweight or normal-weight concrete over metal deck floor and roof assemblies, as shown in Figure A, calculation of the concrete breakout strength may be omitted. 4. In accordance with ACI 318 Section D.5.3.2, the nominal pullout strength in cracked concrete for anchors installed in the soffit of sand-lightweight or normal-weight-concrete-over-metal-deck floor and roof assemblies Npn,deck,cr shall be substituted for Npn,cr. Where analysis indicates no cracking at service loads, the normal pullout strength in uncracked concrete Npn,deck,uncr shall be substituted for Npn,uncr. 5. In accordance with ACI 318 Section D.6.1.2 (c), the shear strength for anchors installed in the soffit of sand-lightweight or normal-weight concrete over metal deck floor and roof assemblies V sa,deck and Vsa, deck,eq shall be substituted for Vsa. 6. Minimum distance to edge of panel is 2hef. 7. The minimum anchor spacing along the flute must be the greater of 3hef or 1.5 times the flute width.
Min. 1" for anchors installed in lower ute. Min. 3" for anchors installed upper ute. Min. 34" typ.
Max. 3"
Min. 412"
Upper ute Min. 412" Min. 12" typ. Max. 1" offset, typ.
Titen HD Tension and Shear Strength Design Data for Normal-Weight or Sand-Lightweight Concrete over Metal Deck1,2,6
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
Tension Loads in Normal-Weight Concrete
Size in. (mm) Tension Load Drill Embed. Critical Critical Bit Depth Edge Spacing f'c 2000 psi f'c 3000 psi Dia. in. Dist. Dist. (13.8 MPa) Concrete (20.7 MPa) Concrete in. (mm) in. in. Ultimate Std. Dev. Allowable Allowable (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 234 4,297 1,075 1,315 (70) (19.1) (4.8) (5.8) 3 6 3 8 (76) (152) 7,087 347 1,770 2,115 334 (95) (31.5) (1.5) (7.9) (9.4) 234 4,610 1,155 1,400 (70) (20.5) (5.1) (6.2) 5 8 4 8 7,413 412 1,855 2,270 3 1 2 (92) (102) (203) (33.0) (1.8) (8.3) (10.1) 534 10,278 297 2,570 3,240 (146) (45.7) (1.3) (11.4) (14.4) 234 4,610 1,155 1,400 (70) (20.5) (5.1) (6.2) 5 10 8,742 615 2,185 2,630 418 5 8 (127) (254) (105) (38.9) (2.7) (9.7) (11.7) 534 12,953 1,764 3,240 3,955 (146) (57.6) (7.8) (14.4) (17.6) 234 4,674 1,170 1,405 (70) (20.8) (5.2) (6.3) 6 12 10,340 1,096 2,585 3,470 458 3 4 (117) (152) (305) (46.0) (4.9) (11.5) (15.4) 534 13,765 1,016 3,440 4,055 (146) (61.2) (4.5) (15.3) (18.0) f'c 4000 psi (27.6 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 6,204 1,550 (27.6) (6.9) 9,820 1,434 2,455 (43.7) (6.4) (10.9) 6,580 1,645 (29.3) (7.3) 10,742 600 2,685 (47.8) (2.7) (11.9) 15,640 2,341 3,910 (69.6) (10.4) (17.4) 6,580 1,645 (29.3) (7.3) 12,286 1,604 3,070 (54.7) (7.1) (13.7) 18,680 4,670 (83.1) (20.8) 6,580 1,645 (29.3) (7.3) 17,426 1,591 4,355 (77.5) (7.1) (19.4) 18,680 1,743 4,670 (83.1) (7.8) (20.8)
*See page 13 for an explanation of the load table icons
(9.5)
(12.7)
(15.9)
(19.1)
Mechanical Anchors
(9.5)
(12.7)
(15.9)
(19.1)
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for spacing and edge distance on pages 119120.
3. The minimum concrete thickness is 112 times the embedment depth. 4. Tension and Shear loads for the Titen HD anchor may be combined using the elliptical interaction equation (n=53). Allowable load may be interpolated for concrete compressive strengths between 2000 psi and 4000 psi.
115
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
Shear Loads in Normal-Weight Concrete, Load Applied Parallel to Concrete Edge
Shear Load Based on Size Drill Bit Embed. Minimum Minimum Minimum Concrete Edge Distance in. Dia. Depth Edge End Spacing (mm) in. in. Dist. Dist. Dist. f'c 2500 psi (17.2 MPa) Concrete (mm) in. in. in. Ultimate Std. Dev. Allowable (mm) (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) 234 4,660 575 1,165 (70) (20.7) (2.6) (5.2) 314 1,530 1 (83) (6.8) 134 8 8 2 1 2 1 (45) (203) (203) (12.7) 6,840 860 1,710 3 2 Note: Rebar not (89) (30.4) (3.8) (7.6) shown for clarity. 1 4 2 7,800 300 1,950 (114) (34.7) (1.3) (8.7) 234 4,820 585 1,205 (70) (21.4) (2.6) (5.3) 5 314 134 10 10 1,580 8 5 1. The allowable loads listed are based 8 (83) (45) (254) (254) (7.0) (15.9) on a safety factor of 4.0. 1 7,060 1,284 1,765 3 2 2. The minimum concrete thickness is 112 (89) (31.4) (5.7) (7.9) times the embedment depth.
*See page 13 for an explanation of the load table icons
Mechanical Anchors
The Titen HD screw anchor may be used for sill plate applications. Use bearing plates as required by code. Refer to the appropriate code report or use Simpson Strong-Tie ACI 318 Anchor Selector software for anchor design information.
116
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
*
Tension Loads in Normal-Weight Concrete, Load Applied at 60 Angle to Horizontal for Tilt-Up Wall Braces
Size Drill Bit Embed. in. Dia. Depth (mm) in. in. (mm)
Tension Applied at 60-degrees to Horizontal f'c 2500 psi (17.2 MPa) Concrete Ultimate Std. Dev. Allow. lbs. (kN) lbs. (kN) lbs. (kN)
(12.7)
10 (254)
6 (152)
(kN) 8 15,420 134 (203) (68.6) (44) 438 14,280 (111) (63.5)
(kN) (kN) (kN) 3,855 20,300 5,075 (17.1) (90.3) (22.6) 3,570 19,040 4,760 (15.9) (84.7) (21.2)
(15.9)
3
8 4
8 4
(19.1)
5 (127) 5 (127)
1. The allowable loads are based on a safety factor of 4.0. 2. The minimum anchor spacing is 15 inches.
3. The minimum concrete thickness (depth) is 12 inches. 4. Allowable loads may be interpolated for compressive strengths between 2,500 and 4,500 psi.
1. The allowable loads are based on a safety factor of 4.0. 2. Anchor must be installed into a concrete floor slab, footing, or deadman with sufficient area, weight, and strength to resist the anchorage load. 3. Titen HD has been qualified for temporary outdoor use of up to 90 days through testing for this application.
Mechanical Anchors
614" 3" LOWER FLUTE UPPER FLUTE 112" 412" 712" 412" MIN. 20 GAUGE STEEL DECK
Figure A Titen HD screw anchor installed in the top and bottom of a structural sand-lightweight-concrete and metal-deck assembly
117
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Titen HD Heavy Duty Screw Anchor for Cracked and Uncracked Concrete
Tension and Shear Loads in 8-inch Lightweight, Medium-Weight and Normal-Weight Grout-Filled CMU
Size in. (mm) Drill Min. Bit Embed. Dia. Depth in. in. (mm)
3 1
3 1
(9.5) (12.7)
5
8 2
(15.9)
3
8 4
8 4
(19.1)
Critical Critical Critical Values for 8-inch Lightweight, Medium-Weight or Normal-Weight Grout-Filled CMU Edge End Spacing Dist. Dist. Dist. Tension Load Shear Load in. in. in. Ultimate Allowable Ultimate Allowable (mm) (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in the Face of the CMU Wall (See Figure 1) 234 12 12 6 2,390 480 4,340 870 (70) (305) (305) (152) (10.6) (2.1) (19.3) (3.9) 312 12 12 8 3,440 690 6,920 1,385 (89) (305) (305) (203) (15.3) (3.1) (30.8) (6.2) 412 12 12 10 5,300 1,060 10,420 2,085 (114) (305) (305) (254) (23.6) (4.7) (46.4) (9.3) 512 12 12 12 7,990 1,600 15,000 3,000 (140) (305) (305) (305) (35.5) (7.1) (66.7) (13.3)
Figure 1
4" Minimum edge distance Critical edge distance (see load table) Installation in this area for reduced allowable load capacity
4" Minimum end distance Critical end distance (see load table) No installation within 1" of head joint
1. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 2. Values for 8-inch wide, lightweight, medium-weight and normal-weight concrete masonry units. 3. The masonry units must be fully grouted. 4. The minimum specified compressive strength of masonry, f'm, at 28 days is 1,500 psi. 5. Embedment depth is measured from the outside face of the concrete masonry unit. 6. Allowable loads may be increased 3313% for short-term loading due to wind or seismic forces where permitted by code. 7. Grout-filled CMU wall design must satisfy applicable design standards and be capable of withstanding applied loads. 8. Refer to allowable load-adjustment factors for spacing and edge distance on page 121.
Shaded Area = Placement for Full and Reduced Allowable Load Capacity in Grout-Filled CMU
Tension and Shear Loads in 8-inch Lightweight, Medium-Weight and Normal-Weight Hollow CMU
Mechanical Anchors
Drill Embed. Min. Bit Depth 4 Edge Dia. in. Dist. in. (mm) in. (mm)
8-inch Hollow CMU Loads Based Min. on CMU Strength 1. The tabulated allowable loads are based on a safety factor of End 5.0 for installations under the IBC and IRC. Dist. Tension Load Shear Load 2. Values for 8-inch wide, lightweight, medium-weight in. and normal-weight concrete masonry units. (mm) Ultimate Allowable Ultimate Allowable 3. The minimum specified compressive lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) strength of masonry, f'm, at 28 days Figure 2 is 1,500 psi. Anchor Installed in Face Shell (See Figure 2)
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
(9.5)
1
8 2
4 458 (102) (117) 4 458 (102) (117) 4 458 (102) (117) 4 458 (102) (117)
(12.7)
5
(15.9)
3
8 4
8 4
(19.1)
4. Embedment depth is measured 458" from the outside face of the concrete 4" masonry unit and is based on the anchor being embedded an additional 1 2" through 114" thick face shell. 5. Allowable loads may not be increased for short-term loading due to wind or seismic forces. CMU wall design must satisfy applicable design standards and be capable of withstanding applied loads. 6. Do not use impact wrenches to install in hollow CMU. 7. Set drill to rotation-only mode when drilling into hollow CMU.
Tension and Shear Loads in 8-inch Lightweight, Medium-Weight and Normal-Weight Grout-Filled CMU Stemwall
Size in. (mm) Drill Embed. Min. Bit Depth Edge Dia. in. Dist. in. (mm) in. (mm)
1
*
134" Edge
Figure 3
(12.7)
5
(15.9)
Min. Critical 8-inch Grout-Filled CMU Allowable Loads Based on CMU Strength End Spacing Tension Shear Perp. to Edge Shear Parallel to Edge Dist. Dist. in. in. Ultimate Allowable Ultimate Allowable Ultimate Allowable (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed in Cell Opening or Web (Top of Wall) (See Figure 3) 134 8 8 2,860 570 800 160 2,920 585 (44.5) (203) (203) (12.7) (2.5) (3.6) (0.7) (13.0) (2.6) 134 10 10 2,860 570 800 160 3,380 675 (44.5) (254) (254) (12.7) (2.5) (3.6) (0.7) (15.0) (3.0)
118
1. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 2. Values are for 8-inch wide, lightweight, medium-weight and normal-weight concrete masonry units. 3. The masonry units must be fully grouted. 4. The minimum specified compressive strength of masonry, f'm, at 28 days is 1,500 psi. 5. Allowable loads may be increased 3313% for short-term loading due to wind or seismic forces where permitted by code. 6. Grout-filled CMU wall design must satisfy applicable design standards and be capable of withstanding applied design loads. 7. Loads are based on anchor installed in either the web or grout-filled cell opening in the top of wall.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
4. Locate the edge distance (Cact) at which the anchor is to be installed. 5. The load adjustment factor (fc) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load adjustment factor(s). 7. Reduction factors for multiple edges are multiplied together.
*
1
234 4 134 0.67 0.67 0.71 0.74 0.78 0.82 0.85 0.89 0.93 0.96 1.00
358 4 134 0.57 0.57 0.62 0.67 0.71 0.76 0.81 0.86 0.90 0.95 1.00
534 4 134 0.73 0.73 0.76 0.79 0.82 0.85 0.88 0.91 0.94 0.97 1.00
234 5 134 0.67 0.67 0.70 0.72 0.75 0.77 0.80 0.82 0.85 0.87 0.90 0.92 0.95 0.97 1.00
418 5 134 0.57 0.57 0.60 0.64 0.67 0.70 0.74 0.77 0.80 0.83 0.87 0.90 0.93 0.97 1.00
534 5 134 0.59 0.59 0.62 0.65 0.68 0.72 0.75 0.78 0.81 0.84 0.87 0.91 0.94 0.97 1.00
234 6 134 0.67 0.67 0.69 0.71 0.73 0.75 0.77 0.79 0.81 0.83 0.84 0.86 0.88 0.90 0.92 0.94 0.96 0.98 1.00
458 6 134 0.48 0.48 0.51 0.54 0.57 0.60 0.63 0.66 0.69 0.72 0.76 0.79 0.82 0.85 0.88 0.91 0.94 0.97 1.00
534 6 134 0.58 0.58 0.60 0.63 0.65 0.68 0.70 0.73 0.75 0.78 0.80 0.83 0.85 0.88 0.90 0.93 0.95 0.98 1.00
Mechanical Anchors
*
1
234 412 134 0.25 0.25 0.32 0.45 0.59 0.73 0.86 1.00
334 412 134 0.24 0.24 0.31 0.45 0.59 0.72 0.86 1.00
234 6 134 0.25 0.25 0.29 0.38 0.47 0.56 0.65 0.74 0.82 0.91 1.00
358 6 134 0.20 0.20 0.25 0.34 0.44 0.53 0.62 0.72 0.81 0.91 1.00
534 6 134 0.17 0.17 0.22 0.32 0.41 0.51 0.61 0.71 0.80 0.90 1.00
234 712 134 0.19 0.19 0.23 0.30 0.37 0.44 0.51 0.58 0.65 0.72 0.79 0.86 0.93 1.00
418 712 134 0.16 0.16 0.20 0.27 0.34 0.42 0.49 0.56 0.63 0.71 0.78 0.85 0.93 1.00
534 712 134 0.19 0.19 0.23 0.30 0.37 0.44 0.51 0.58 0.65 0.72 0.79 0.86 0.93 1.00
234 9 134 0.19 0.19 0.22 0.27 0.33 0.39 0.44 0.50 0.55 0.61 0.66 0.72 0.78 0.83 0.89 0.94 1.00
458 9 134 0.14 0.14 0.17 0.23 0.29 0.35 0.41 0.47 0.53 0.58 0.64 0.70 0.76 0.82 0.88 0.94 1.00
534 9 134 0.13 0.13 0.16 0.22 0.28 0.34 0.40 0.46 0.52 0.58 0.64 0.70 0.76 0.82 0.88 0.94 1.00
The tabled adjustment values (fc) have been calculated using the following information: 1. E = Embedment depth (inches). 2. Cact = actual edge distance at which anchor is installed (inches). 3. Ccr = critical edge distance for 100% load (inches). 4. Cmin = minimum edge distance for reduced load (inches). 5. fc = percent of allowable load at actual edge distance. 6. fccr = percentage of allowable load at critical edge distance. fccr is always = 1.00. 7. fcmin = percent of allowable load at minimum edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
119
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
4. Locate the spacing (Sact) at which the anchor is to be installed. 5. The load adjustment factor (fs) is the intersection of the row and column. 6. Multiply the allowable load by the applicable load adjustment factor(s). 7. Reduction factors for multiple spacings are multiplied together.
*
3
234 6 112 0.66 0.66 0.70 0.74 0.77 0.85 0.92 1.00
334 6 112 0.56 0.56 0.61 0.66 0.71 0.80 0.90 1.00
234 8 2 0.72 0.72 0.74 0.77 0.81 0.86 0.91 0.95 1.00
358 8 2 0.63 0.63 0.66 0.69 0.75 0.82 0.88 0.94 1.00
534 8 2 0.76 0.76 0.78 0.80 0.84 0.88 0.92 0.96 1.00
234 12 3 0.80
458 12 3 0.70
534 12 3 0.72
Mechanical Anchors
0.80 0.82 0.84 0.87 0.89 0.91 0.93 0.96 0.98 1.00
0.70 0.73 0.77 0.80 0.83 0.87 0.90 0.93 0.97 1.00
0.72 0.75 0.78 0.81 0.84 0.88 0.91 0.94 0.97 1.00
* 8
1
0.77 0.80 0.82 0.85 0.87 0.90 0.92 0.95 0.97 1.00
0.77 0.80 0.82 0.85 0.87 0.90 0.92 0.95 0.97 1.00
0.77 0.80 0.82 0.85 0.87 0.90 0.92 0.95 0.97 1.00
120
2 4 8 2 0.77
3
3 8 8 2 0.77
5
5 4 8 2 0.77
3
2 4 10 212 0.77
3
4 8 10 212 0.77
1
5 4 10 212 0.77
3
2 4 12 3 0.77
3
458 12 3 0.77
534 12 3 0.77
The tabled adjustment values (fs) have been calculated using the following information: 1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
1
Edge and End Distance Shear (fc) Shear Load Parallel to Edge or End
Cact (in.) 4 6 8 10 12
See Notes Below
*
5
Edge or End Distance Shear (fc) Shear Load Perpendicular to Edge or End (Directed Towards Edge or End)
Cact (in.) 4 6 8 10 12 Dia. E Ccr Cmin fcmin
3
*
3
Edge or End Distance Shear (fc) Shear Load Perpendicular to Edge or End (Directed Away From Edge or End)
Cact (in.) 4 6 8 10 12 Dia. E Ccr Cmin fcmin
3
*
3
Mechanical Anchors
1. E = Embedment depth (inches). 2. Cact = actual end or edge distance at which anchor is installed (inches). 3. Ccr = critical end or edge distance for 100% load (inches). 4. Cmin = minimum end or edge distance for reduced load (inches). 5. fc = adjustment factor for allowable load at actual end or edge distance. 6. fccr = adjustment factor for allowable load at critical end or edge distance. fccr is always = 1.00. 7. fcmin = adjustment factor for allowable load at minimum end or edge distance. 8. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
*
1
* 8
3
3 2 8 4 0.69
1
4 2 10 5 0.59
1
5 2 12 6 0.50
1
3 2 8 4 0.62
1
4 2 10 5 0.62
1
512 12 6 0.62
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
121
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Installation Sequence
Mechanical Anchors
Size
1 1
*
Tension Load
*See page 13 for an f'c 4000 psi Concrete explanation Ultimate lbs. (kN) Allowable lbs. (kN) of the load table 1,037 (4.6) 260 (1.2) icons
4 8
(6.4) (9.5)
4 8
f'c 2000 psi Concrete Ultimate lbs. (kN) Allowable lbs. (kN) 624 (2.8) 155 (0.7) 1,768 (7.9) 440 (2.0) 2,070 (9.2) 520 (2.3)
*
Min. Edge Dist. in. (mm) 4 (102) 6 (152) Shear Load f'c 4000 psi Concrete f'c 2000 psi Concrete Ultimate lbs. (kN) Allowable lbs. (kN) Ultimate lbs. (kN) Allowable lbs. (kN) 1,104 (4.9) 275 (1.2) 2,135 (9.5) 535 (2.4) 2,443 (10.9) 610 (2.7) 610 (2.7) 2,912 (13.0) 730 (3.2) 3,668 (16.3) 915 (4.1)
3. Tension and Shear loads may be combined using the straight line interaction equation (n=1).
4 (6.4) 8 (9.5)
4 8
1. The allowable loads are based on a safety factor of 4.0. 2. The minimum concrete thickness is 1 12 times the embedment depth.
Tension and Shear Loads in 8-inch Lightweight, Medium-Weight and Normal-Weight Hollow CMU
8-inch Hollow CMU Loads Based on CMU Strength Min. Min. End Size in. Drill Bit Embed. Edge Tension Load Shear Load 4 Depth Dist. in. Dist. in. (mm) Dia. in. in. Ultimate Allowable Ultimate Allowable 4. Embedment depth is measured from the outside face of the (mm) (mm) (mm) concrete masonry unit and is based on the anchor being lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) embedded an additional 14" through the 114" thick face shell. Anchor Installed in Face Shell (See Figure 1) 5. Allowable loads may not be increased for short-term loading 1 1 4 (6.4) 4 112 (38) 4 (102) 458 (117) 520 (2.3) 105 (0.5) 1,240 (5.5) 250 (1.1) due to wind or seismic forces. CMU wall design must satisfy 3 3 8 (9.5) 8 112 (38) 4 (102) 458 (117) 720 (3.2) 145 (0.6) 1,240 (5.5) 250 (1.1) applicable design standards and be capable of withstanding
122
1. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 2. Values for 8-inch wide, lightweight, medium-weight, and normal-weight CMU. 3. The minimum specied compressive strength of masonry, f'c, at 28 days is 1,500 psi.
applied loads. 6. Set drill to rotation-only mode when drilling into hollow CMU. 7. Do not use impact wrenches to install in hollow CMU.
4" x 1 4" 4" x 214" 1 4" x 3" 3 8" x 134" 3 8" x 212"
3
"2"min.
min
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
IBC
2009
ESR-2713
FEATURES: High-load capacity as a result of the full-length threads that undercut the concrete and effectively transfer load into the base material Specialized heat-treating process creates greater hardness at the tip to facilitate cutting while the body remains ductile Serrated cutting teeth and patented thread design enable quick and easy installation No special installation tools required. Holes can be drilled with a rotary hammer or hammer drill with standard ANSI-size bit. Anchors are installed with standard-size sockets. MATERIAL: Carbon steel, heat treated FINISH: Zinc plated INSTALLATION: Caution: Oversized holes in the base material will reduce or eliminate the mechanical interlock of the threads with base material and will reduce the anchors load capacity. Use a Titen HD Rod Hanger one time only. Installing the anchor multiple times may result in excessive thread wear and reduce load capacity Drill a hole using the specified diameter carbide bit into the base material to a depth of at least 12" deeper than the required embedment. Blow the hole clean of dust and debris using compressed air. IMPORTANT: Install with an applied torque of 15 ft-lbs for the THD25112RH and THD37218RH rod hangers using a torque wrench, driver drill, hammer drill or cordless 14" impact driver with a maximum permitted torque rating of 100 ft-lb. CODES: ICC-ES ESR-2713 (THD37212RH and THD50234RH), Factory Mutual 3031136 (THD50234RH and THD37218RH) and 3035761 (THD37212RH) THD50234RH (38" dia. shank) THD37212RH (38" dia. shank) THD37218RH THD25112RH
Mechanical Anchors
Installation Sequence
Accepts Drill Bit Wrench Min. Size Embed. Rod Dia. Dia. (in.) (in.) (in.) (in.)
1 3 3 1
4 x 1 2
1
4 8 8 2
1 1 3 3
4 4
3 1 1 11
8 2 2 16
1 2
1
100 50 50 50
8 x 2 8
1 1 8 x 2 2 3 2 x 2 4
2 8
1 1 2 2 3 2 4
8 8
1. Drill a hole using the specied diameter carbide bit into the base material to a depth of at least 12" deeper than the required embedment.
2. Blow the hole clean of dust and debris using compressed air.
3. Insert anchor into the hole. Tighten the anchor with an impact wrench or a torque wrench into the base material until the hex washer head contacts the base material.
123
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Units
do dbit Tinst,max Timpact,max hhole hnom hef cac cmin smin hmin Anchor Data
in. in. ft-lbf ft-lbf in. in. in. in. in. in. in.
3 3
8 8
50 150 3
1 2 2
50 150
1 3 4 3 2 4
Maximum Impact Wrench Torque Rating Minimum Hole Depth Embedment Depth Effective Embedment Depth Critical Edge Distance Minimum Edge Distance Minimum Spacing Minimum Concrete Thickness
1.77 2 16
11 3 1 4
1.77
11 2 16
3
1 4 4 1 4 4
Yield Strength Tensile Strength Minimum Tensile and Shear Stress Area
Mechanical Anchors
Axial Stiffness in Service Load Range Uncracked Concrete Axial Stiffness in Service Load Range Cracked Concrete
uncr cr
124
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2. Tinst,max is the maximum permitted installation torque for installations using a torque wrench. 3. Timpact,max is the maximum permitted torque rating for impact wrenches.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
THD50234RH
Steel Strength in Tension (ACI 318 Section D.5.1) Tension Resistance of Steel Strength Reduction Factor Steel Failure2 Nsa Ib.
6
10,890 0.65
10,890
Concrete Breakout Strength in Tension (ACI 318 Section D.5.2) Effective Embedment Depth Critical Edge Distance Effectiveness Factor Uncracked Concrete Effectiveness Factor Cracked Concrete Modification Factor Strength Reduction Factor Concrete Breakout Failure
5
in. in.
6
1.77 2 16
11
1.77
11 2 16
24 17 1.0 0.65
c,N
Pullout Strength in Tension (ACI 318 Section D.5.3) Pullout Resistance Uncracked Concrete (f'c = 2500 psi) Pullout Resistance Cracked Concrete (f'c = 2500 psi) Strength Reduction Factor Pullout Failure4 Np,uncr Np,cr Ib. Ib.
2,0253 1,2353
Mechanical Anchors
Tension Strength for Seismic Applications (ACI 318 Section D.3.3.3)6 Nominal Pullout Strength for Seismic Loads (f'c = 2500 psi) Strength Reduction Factor Pullout Failure4
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Np,eq
Ib.
1,2353 0.65
1,2353
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The value of applies when the load combinations of ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . Anchors are considered brittle steel elements. 3. Adjust the characteristic pullout resistance for other concrete compressive strengths by multiplying the tabular value by (f'c,specified / 2500) 0.5. 4. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of .
5. The value of applies when both the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Section 9.2 are used and the requirements of Section D.4.4(c) for Condition A are met, refer to Section D.4.4 to determine the appropriate value of . If the load combinations of ACI 318 Appendix C are used, refer to Section D.4.5 to determine the appropriate value of . 6. For sand-lightweight concrete, the modication factor for concrete breakout strength must be taken as 0.6. Additionally, the pullout strength N p,uncr, Np,cr and Np.eq must be multiplied by 0.6, as applicable. 7. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength, Np,cr, Np,uncr and Neq by 0.6. All-lightweight concrete is beyond the scope of this table.
125
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. Concrete compressive strength shall be 3000 psi minimum. The characteristic pullout resistance for greater compressive strengths shall be increased by multiplying the tabular value by (f'c, specified /3000 psi)0.5. 3. For anchors installed in the soffit of sand-lightweight or normal-weight concrete over metal deck floor and roof assemblies, as shown in Figure A, calculation of the concrete breakout strength may be omitted. 4. In accordance with ACI 318 Section D.5.3.2, the nominal pullout strength in cracked concrete for anchors installed in the soffit of sand-lightweight or normal-weight-concrete-over-metal-deck floor and roof assemblies Np,deck,cr shall be substituted for Np,cr. Where analysis indicates no cracking at service loads, the normal pullout strength in uncracked concrete Np,deck,uncr shall be substituted for Np,uncr. 5. Minimum distance to edge of panel is 2hef. 6. The minimum anchor spacing along the flute must be the greater of 3hef or 1.5 times the flute width.
Min. 1" for anchors installed in lower ute. Min. 3" for anchors installed upper ute. Min. " typ.
Max. 3"
Min. 4"
Upper ute Min. 4" Min. 12" typ. Max. 1" offset, typ.
Mechanical Anchors
Allowable Stress Design (ASD) Values for Titen HD Rod Hanger with 14" and 38" Shanks Tension Loads in Normal-Weight Concrete
Tension Load Catalog Number Rod Hanger Dia. (in.) Drill Bit Dia. (in.) Emb. Depth (in.) Critical Edge Distance (in.) Critical Spacing Distance (in.) f'c 2000 psi Concrete Ultimate (lbs.) 1,319 2,210 3,650 4,297 Allowable (lbs.) 330 555 915 1,075
4 4
1 1 2 1 2 8 1 2 2 3 2 4
3 3 3 3
6 6 6 6
8 8 2
8 8
1. The allowable loads listed are based on a safety factor of 4.0. 2. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 3. Refer to allowable load-adjustment factors for spacing and edge distance on pages 120121. 4. The minimum concrete thickness is 112 times the embedment depth. 5. Allowable load may be interpolated for concrete compressive strengths between 2000 psi and 4000 psi.
126
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Mechanical Anchors
8 x 634 2 x 9 4
3
8 2
8 2
16 4
Installation Sequence
12
" min.
2" min.
127
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13 for an explanation of the load table icons
Minimum Minimum Edge End Dist. Dist. in. in. (mm) (mm)
Minimum Spacing Dist. f'c 2500 psi (17.2 Mpa) in. Concrete (mm) Ultimate Allowable lbs. (kN) lbs. (kN) 20 (508) 32 (813) 8,900 (39.6) 15,540 (69.1) 2,225 (9.9) 3,885 (17.3)
(9.5)
1
8 2
5 (127) 8 (203)
8 (203) 8 (203)
10 (254) 16 (406)
(12.7)
1. Allowable load must be the lesser of the concrete or steel strength. 2. The allowable loads based on concrete strength are based on a factor of safety of 4.0. 3. The allowable load based on steel strength is limited by the strength of the coupler nut supplied with this anchor. Use of higher strength rod will not increase allowable loads. 4. The minimum concrete thickness is 1.5 times the embedment depth. 5. Tension and shear loads may be combined using the straight-line interaction equation (n=1).
Titen HD Rod Coupler Shear Loads in Normal-Weight Concrete Stemwall, Load Applied Parallel to Concrete Edge
*
Minimum Spacing Dist. in. (mm) 32 (813) Shear Load Based on Conc. Edge Dist. f'c 2500 psi (17.2 Mpa) Concrete Ultimate lbs. (kN) 6,200 (27.6) Allowable lbs. (kN) 1,550 (6.9)
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Mechanical Anchors
1 2 (12.7)
1. Install with a washer (not supplied with anchor) when used to resist shear loads. 2. The allowable load based on concrete edge distance is based on a factor of safety of 4.0. Steel strength does not control. 3. The minimum concrete thickness is 1.5 times the embedment depth. 4. Tension and shear loads may be combined using the straight-line interaction equation (n=1).
128
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
IBC
2009
PENDING
FEATURES: Self-undercutting feature provides higher load carrying capacity than conventional mechanical anchors AC193 code tested to ensure outstanding performance in both cracked and uncracked concrete Excellent for resisting seismic and vibratory loads Suitable for Seismic Design Categories A-F Ductile steel rod provides consistent, reliable performance Specially designed, low-friction expansion cone minimizes binding and speeds installation Installs just like a conventional expansion anchor, no special tool, drill bit, or secondary drilling is required The head is stamped with the SimpsonStrong-Tie "" sign and size identification for easy post installation verification MATERIAL: ASTM A193 grade B7 or B7M rod with SAE J403 grade 1144 undercut expansion ring and expansion cone FINISH: Zinc plated CODES: ICC-ES pending The load tables list values based upon results from the most recent testing and may not reflect those in current code reports. Where additonal local jurisdiction requirements apply, consult the current reports for applicable load values. TEST CRITERIA: The Torq-Cut anchor has been tested in accordance with ICC-ES's Acceptance Criteria for Mechanical Anchors in Concrete Elements (AC193) and ACI 355.2 for the following: Static tension and shear loading in cracked and uncracked concrete Seismic and wind loading in cracked and uncracked concrete Performance in cracked concrete Torq-Cut Setting Tool The TCAST is the steel setting tool used to install the Torq-Cut anchor. It is used to drive the anchor into the pre-drilled hole and protect the threads on the Torq-Cut from being damaged by hammer blows. INSTALLATION: Caution: Oversized holes in the base material will make it difcult to set the anchor and will reduce the anchors load capacity. Do not use an impact wrench to set or tighten the Torq-Cut anchor. Installation Instructions: Pre-Set Version 1. Drill a hole in the base material to the specified embedment depth using the appropriate diameter carbide drill bit specified for each diameter. 2. Blow the hole clean using compressed air. 3. Assemble the anchor with nut and washer and finger tighten nut so all components are snug (spacer sleeve, expansion sleeve and cone). The bottom of the threaded rod should be flush with the bottom of the cone. 4. Place the anchor into the drilled hole and use a hammer and setting tool to drive the anchor until the washer and nut are tight against the surface of the base material. 5. Remove the nut and washer and install the fixture. Re-assemble the nut and washer over the fixture. 6. Tighten to the required installation torque. Installation Instructions: Through-Set Version 1. Drill a hole in the base material to the specified embedment depth using the appropriate diameter carbide drill bit specified for each diameter. 2. Blow the hole clean using compressed air. 3. Assemble the anchor with nut and washer and finger tighten nut so all components are snug (spacer sleeve, expansion sleeve and cone). The bottom of the threaded rod should be flush with the bottom of the cone. 4. Place the anchor through the fixture and into the drilled hole. Use a hammer and setting tool to drive the anchor until the washer and nut are tight against the fixture. 5. Tighten to the required installation torque. APPLICATION: Interior environment where low levels of moisture and corrosive chemicals are present SUGGESTED SPECIFICATIONS: Self-undercutting anchors shall have an expansion ring with undercutting teeth which expands by tightening the nut that pushes the ring into a cone expander via a spacer sleeve. The anchor shall have been tested and qualied for performance in cracked and uncracked concrete per ACI 355.2 and ICC-ES AC193. Undercut anchor shall be the TorqCut self-undercutting anchor from SimpsonStrong-Tie, Pleasanton, CA, and be installed following the SimpsonStrong-Tie instructions. Torq-Cut Self-Undercutting Anchor
U.S. Patent 7,357,613
Installation Sequence
Steps 1, 2, 3 Pre-Set and Through-Set Version 1 2 3
Mechanical Anchors
8 8
9
2 8
11
8 1
13
3 4 114
1612
11
1634
15
1678
16118 1516
16
16
1116
129
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Min. Drilled Drill Bit Dia. Hole Depth (in.) (A) (in.)
5
Min. Effective Max. Fixture Embedment Thickness Depth, hef (F) (in.) (C) (in.) 4 534 534 8 8 1014 1014
3
Threaded Rod Length (D) (in.) 6 834 912 1112 1212 1458 1658
8 x 6
5 2
1
16 16 16 16 16
2 x 834
7 7
8 8
2 x 912
1 1 114 114
11 11
13 13
16 16
Min. Effective Max. Fixture Embedment Thickness Depth, hef (F) (in.) (C) (in.) 4 534 534 8 8 1014 1014
3
Threaded Rod Length (D) (in.) 6 834 912 1112 1212 1458 1658
8 x 6
16
2 x 834
7 7
8 8
15 15
16
2 x 912
16
1 1 114 114
Mechanical Anchors
SAE J403 Grade 1144 Steel Zinc Plated ASTM B633 SC1
1. 38" TCA uses ASTM A193 Grade B7 rod. 12", 58" and 34" TCA uses ASTM A193 Grade B7M rod.
Through-Set
Fixture Thickness, tx
d Threaded Effective Rod Embedment 3 Length Depth , hef (D) (C) Nominal Embedment Depth2, hnom (B)
130
1. The notation in parentheses is for the 2006 IBC. 2. The Drilled Hole Depth is 12" greater than the Nominal Embedment Depth. 3. For the Through-Set version of the Torq-Cut anchor, if the actual Fixture Thickness (tfix) is less than the Maximum Fixture Thickness (F), the Minimum Drilled Hole Depth (A) must be increased as follows: Drilled Hole Depth = A + (F-tfix) Similarly, the Minimum Effective Embedment Depth (C) is increased as follows: Effective Embedment Depth = C + (F-tfix)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8
8
9
2
8
11
8
13
Installation Information Drill Bit Diameter d in. Pre-Set Fixture Hole Diameter Range2 dc in. Through-Set Minimum Fixture Hole Diameter2 dc in. Installation Torque Tinst ft-lb in. Minimum Nominal Embedment Depth hnom Minimum Overall Depth of Drilled Hole hhole in. Critical Edge Distance cac in. Minimum Edge Distance cmin in. Minimum Spacing smin in. Minimum Concrete Thickness hmin in. Additional Data Anchor Category category Yield Strength fya ksi Tensile Strength futa ksi Effective Tensile and Shear Stress Area Ase in 2 Axial Stiffness in Service Load Range uncracked concrete lb/in. uncr Axial Stiffness in Service Load Range - cracked concrete lb/in. cr
5
7
1
1678
114
16118
1612
11
1634
15
16 55 5 512 6 6 6 6
1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2. The clearance must comply with applicable code requirements for the connected element.
*
Symbol hnom Units in.
Mechanical Anchors
9 2
1
12 33,450
9,690 sa Concrete Breakout Strength in Tension6 hef Minimum Effective Embedment Depth in. 4 cac Critical Edge Distance in. 6 k Effectiveness Factor Uncracked Concrete 24 uncr kcr 17 Effectiveness Factor Cracked Concrete c,N Modification Factor 1.0 Strength Reduction Factor Concrete Breakout Failure cb Pullout Strength in Tension6 Np,uncr Pullout Strength Uncracked Concrete lb 7,4007 Np,cr Pullout Strength Cracked Concrete lb 6,9507 Strength Reduction Factor - Pullout Failure 0.654,7 p Tension Resistance for Seismic Applications6 Neq Tension Resistance - Seismic Loads lb 9,690 Strength Reduction Factor Steel Failure sa Strength Reduction Factor Steel Failure
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The tabulated value of sa applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used. If the load combinations of ACI 318 Appendix C are used, the appropriate value of sa must be determined in accordance with ACI 318 D.4.5. Torq-Cut anchors are ductile steel elements as defined in ACI 318 D.1. 3. N/A (Not Applicable) denotes that pullout resistance does not need to be considered. 4. The tabulated value of p applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, appropriate value of must be determined in accordance with ACI 318 Section D.4.5(c).
22,600
8 12 24 17 1.0
14,190 0.75 2
22,600
5. The tabulated value of cb applies when both the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4(c) for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be verified, the cb factors described in ACI 318 D.4.4 for Condition A are allowed. If the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4 for Condition A are met, the appropriate value of cb must be determined in accordance with ACI 318 D.4.4(c). If the load combinations of ACI 318 Appendix C are used, the appropriate value of cb must be determined in accordance with ACI 318 D.4.5(c). 6. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength, Np,cr, Np,uncr and Neq by 0.6. Alllightweight concrete is beyond the scope of this table. 7. Pullout strength applies for 2500 psi f'c 3500 psi concrete. For f'c > 3500 psi concrete, pullout strength need not be considered since steel controls for concrete strengths greater than 3500 psi.
131
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
* 8 2 8 4
*See page 13 for an explanation of the load table icons
912
12
5,815
8,515
13,560 0.65 2
20,070
sa
1 5.8 0.70 3
114 7.5
e cb
in.
2.8
4.3
Concrete Pryout Strength in Shear Coefficient for 2.0 2.0 2.0 kcp Pryout Strength Strength Reduction Factor 0.70 4 cp Concrete Pryout Failure Steel Strength in Shear for Seismic Applications Steel Strength in lb 5,815 8,515 13,560 Veq Shear for Seismic Loads Strength Reduction Factor 0.65 2 sa Steel Failure
2.0
20,070
132
1. The information presented in this table must be used in conjunction with the design criteria of ACI 318 Appendix D, except as modified below. 2. The tabulated value of sa applies when the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, the appropriate value of sa must be determined in accordance with ACI 318 D.4.5. Torq-Cut anchors are ductile steel elements as defined in ACI 318 D.1. 3. The tabulated value of cb applies when both the load combinations of Section 1605.2.1 of the IBC, or ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4(c) for Condition B are met. Condition B applies where supplementary reinforcement is not provided. For installations where complying supplementary reinforcement can be verified, the cb factors described in ACI 318 Section D.4.4 for Condition A are allowed. If the load combinations of ACI 318 Section 9.2 are used and the requirements of ACI 318 Section D.4.4 for Condition A are met, the appropriate value of cb must be determined in accordance with ACI 318 Section D.4.4(c). If the load combinations of ACI 318 Appendix C are used, the appropriate value of cb must be determined in accordance with ACI 318 Section D.4.5(c). 4. The tabulated value of cp applies when both the load combinations of IBC Section 1605.2.1 or ACI 318 Section 9.2 are used and the requirements of ACI 318 D.4.4(c) for Condition B are met. If the load combinations of ACI 318 Appendix C are used, the appropriate value of cp must be determined in accordance with ACI 318 D.4.5(c). 5. For sand-lightweight concrete, in lieu of ACI 318 Section D.3.4, modify the value of concrete breakout strength by 0.60. All-lightweight concrete is beyond the scope of this table. 6. For the 2006 IBC, do replaces da.
Mechanical Anchors
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Wedge-All Anchor
Tie-Wire Anchor
(Zinc plate only)
Mechanical Anchors
8 8
11
8 34 16 78 15 16 118
5
1 1516
Length Identification Head Marks on Wedge-All Anchors (corresponds to length of anchor inches).
Mark From Up To But Not Including A 112 2 B 2 212 C 212 3 D 3 312 E 312 4 F 4 412 G 412 5 H 5 512 I 512 6 J 6 612 K 612 7 L 7 712 M 712 8 N 8 812 O 812 9 P 9 912 Q 912 10 R 10 11 S 11 12 T 12 13 U 13 14 V 14 15 W 15 16 X 16 17 Y 17 18 Z 18 19 133
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Carbon Steel Model No. TWD25112 4 WA25134 WA25214 WA25314 WA37214 WA37234 WA37300 WA37312 WA37334 WA37500 WA37700 WA50234 WA50334 WA50414 WA50512 WA50700 WA50812 WA50100 WA50120 WA62312 WA62412 WA62500 WA62600 WA62700 WA62812 WA62100 WA62120 WA75414 WA75434 WA75512 WA75614 WA75700 WA75812 WA75100 WA75120 WA87600 WA87800 WA87100 WA87120 WA16000 WA19000 WA11200 WA12590 WA12512
Mechanically Drill Bit Galvanized Dia. Model No. (in.) WA25134MG WA25214MG WA25314MG WA37214MG WA37234MG WA37300MG WA37312MG WA37334MG WA37500MG WA37700MG WA50234MG WA50334MG WA50414MG WA50512MG WA50700MG WA50812MG WA50100MG WA50120MG WA62312MG WA62412MG WA62500MG WA62600MG WA62700MG WA62812MG WA62100MG WA62120MG WA75414MG WA75434MG WA75512MG WA75614MG WA75700MG WA75812MG WA75100MG WA75120MG WA87600MG WA87800MG WA87100MG WA87120MG WA16000MG WA19000MG WA11200MG WA12590MG WA12512MG
1
Material Specifications
Quantity Box 100 100 100 100 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 20 20 20 20 20 20 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 Carton 500 500 500 500 250 250 250 250 250 200 200 125 125 100 100 100 50 50 50 80 80 80 80 80 40 20 20 40 40 40 40 40 20 20 10 20 10 10 10 20 10 10 10 10 Carbon Steel - Zinc Plated Component Materials Anchor Body Material Meets minimum 70,000 psi tensile strength Nut Carbon Steel ASTM A 563, Grade A Washer Carbon Steel Clip Carbon Steel
Mechanical Anchors
Material Specifications
Carbon Steel - Mechanically Galvanized 1 Component Materials Anchor Body Material Meets minimum 70,000 psi tensile strength Nut Carbon Steel ASTM A 563, Grade A Washer Carbon Steel Clip Carbon Steel
1 114
1. The published length is the overall length of the anchor. Allow one anchor diameter for the nut and washer thickness plus the fixture thickness when selecting the minimum length. 2. Special lengths are available on request. Load values are valid as long as minimum embedment depths are satisfied. 3. Tie-Wire Wedge-All anchor, overall length is 2". 4. Tie-Wire Wedge-All anchor also available in bulk quantity of 2,000, model TWD25112B. 5. Bulk packaged Wedge-All anchors available, call Simpson Strong-Tie for details.
Application: Exterior unpolluted environment, medium level of corrosion resistance. Well suited to humid environments. See page 11 for more corrosion information.
134
1716 2716 118 158 178 212 258 378 578 1516 2516 21316 4116 4916 6 6 6 178 278 338 438 538 6 6 6 238 278 358 438 518 6 6 6 218 218 218 218 214 214 214 234 234
16
Application: Interior environment, low level of corrosion resistance. See page 11 for more corrosion information.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Type 304/303 Type 316 Stainless Stainless Model No.1 Model No.2 WA251344SS WA252144SS WA253144SS WA372144SS WA372344SS WA373004SS WA373124SS WA373344SS WA375004SS WA377004SS WA502344SS WA503344SS WA504144SS WA505124SS WA507004SS WA50812SS WA50100SS WA50120SS WA623124SS WA624124SS WA625004SS WA626004SS WA627004SS WA62812SS WA62100SS WA62120SS WA754144SS WA754344SS WA755124SS WA756144SS WA757004SS WA75812SS WA75100SS WA75120SS WA87600SS WA87800SS WA87100SS WA87120SS WA16000SS WA19000SS WA11200SS WA12590SS WA12512SS WA251346SS WA252146SS WA253146SS WA372146SS WA372346SS WA373006SS WA373126SS WA373346SS WA375006SS WA377006SS WA502346SS WA503346SS WA504146SS WA505126SS WA507006SS WA508123SS WA501003SS WA501203SS WA623126SS WA624126SS WA625006SS WA626006SS WA627006SS WA628123SS WA621003SS WA621203SS WA754146SS WA754346SS WA755126SS WA756146SS WA757006SS WA758123SS WA751003SS WA751203SS WA876003SS WA878003SS WA871003SS WA871203SS WA160003SS WA190003SS WA112003SS WA125903SS WA125123SS
Standard Quantity Box 100 100 100 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 20 20 20 20 20 20 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 Carton 500 500 500 250 250 250 250 250 200 200 125 125 100 100 100 50 50 50 80 80 80 80 80 40 20 20 40 40 40 40 40 20 20 10 20 10 10 10 20 10 10 10 10
Mini-Pack Quantity Box 20 20 20 20 20 20 20 20 10 18 10 10 10 4 4 4 4 10 10 10 10 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 43 43 Carton 200 200 200 200 200 200 200 200 100 80 100 100 80 32 16 16 16 100 80 80 80 16 16 16 16 40 40 32 32 32 16 16 16 8 8 8 8 8 8 8 8
Material Specifications
Type 304/303 Stainless Steel 1 Component Materials Anchor Body Nut Washer Clip
1 114
1 16 2716 118 158 178 212 258 378 578 1516 2516 21316 4116 5916 2 2 2 178 278 338 438 538 2 2 2 238 278 358 438 518 214 214 214 218 218 218 218 214 214 214 234 234
7
16
Type 303 Type Type Type 304 and 304 18-8 18-8 or 316 Stainless Stainless Stainless Stainless Steel Steel Steel Steel
1. Type 303 and 304 stainless steels perform equally well in certain corrosive environments. Larger sizes are manufactured from type 303.
Application: Exterior environment, high level of corrosion resistance. Resistant to organic chemicals, many inorganic chemicals, mild atmospheric pollution and mild marine environments (not in direct contact with salt water). See page 11 for more corrosion information.
Material Specifications
Type 316 Stainless Steel 1 Component Materials Anchor Body Nut Washer Clip
Mechanical Anchors
Type Type Type Type 316 316 316 316 Stainless Stainless Stainless Stainless Steel Steel Steel Steel
1. Type 316 stainless steel provides the greatest degree of corrosion resistance offered by Simpson Strong-Tie.
1. Anchors with the SS suffix in the model number are manufactured from type 303 stainless steel, the remaining anchors (with the 4SS suffix) are manufactured from type 304 stainless steel. Type 303 stainless anchors may require extra lead time, call factory for details. Types 303 and 304 stainless steel perform equally well in certain corrosive environments. 2. Anchors with the 3SS suffix in the model number may require extra lead time. Call Simpson Strong-Tie for details. 3. These package quantities available in type 303 stainless steel only. 4. The published length is the overall length of the anchor. Allow one anchor diameter for the nut and washer thickness plus the fixture thickness when selecting a length.
5. Special lengths are available on request. Load values are valid as long as minimum embedment depths are satisfied. Mini Pack: These package quantities must be ordered with a -R suffix on the end of the standard model number. (example: WA505124SS-R).
Application: Exterior environment, high level of corrosion resistance. Resistant to chlorides, sulfuric acid compounds and direct contact with salt water. See page 11 for more corrosion information.
135
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Install. Torque ft-lbs (N-m)
300 (406.7)
400 (542.3)
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for edge distance and spacing on pages 141 and 143. 3. Drill bit diameter used in base material corresponds to nominal anchor diameter. 4. Allowable loads may be linearly interpolated between concrete strengths listed. 5. Allowable loads for 14-inch size at 118-inch embedment apply to both the Wedge-All and Tie-Wire anchors. Installation torque does not apply to the Tie-Wire anchor. 6. The minimum concrete thickness is 112 times the embedment depth.
136
f'c 4000 psi (27.6 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 960 233 240 (4.3) (1.0) (1.1) 2,320 105 580 (10.3) (0.5) (2.6) 2,880 588 720 (12.8) (2.6) (3.2) 5,440 553 1,360 (24.2) (2.5) (6.0) 5,440 318 1,360 (24.2) (1.4) (6.0) 5,280 849 1,320 (23.5) (3.8) (5.9) 9,840 1,303 2,460 (43.8) (5.8) (10.9) 11,840 2,462 2,960 (52.7) (11.0) (13.2) 8,600 729 2,150 (38.3) (3.2) (9.6) 15,720 1,224 3,930 (69.9) (5.4) (17.5) 15,720 1,116 3,930 (69.9) (5.0) (17.5) 9,960 1,324 2,490 (44.3) (5.9) (11.1) 15,760 1,550 3,940 (70.1) (6.9) (17.5) 17,000 1,668 4,250 (75.6) (7.4) (18.9) 10,720 1,253 2,680 (47.7) (5.6) (11.9) 20,320 2,401 5,080 (90.4) (10.7) (22.6) 15,680 1,876 3,920 (69.7) (8.3) (17.4) 30,080 1,612 7,520 (133.8) (7.2) (33.5) 24,760 625 6,190 (110.1) (2.8) (27.5) 48,920 1,693 12,230 (217.6) (7.5) (54.4)
8 (10.8)
30 (40.7)
60 (81.3)
90 (122.0)
Mechanical Anchors
150 (203.4)
200 (271.2)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
(6.4)
14
8 (10.8)
(9.5)
30 (40.7)
(12.7)
60 (81.3)
(15.9)
90 (122.0)
Mechanical Anchors
(19.1)
150 (203.4)
(22.2)
200 (271.2)
1 (25.4)
300 (406.7)
114 (31.8)
400 (542.3)
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for spacing and edge distance on pages 141, 142 and 144. 3. Drill bit diameter used in base material corresponds to nominal anchor diameter. 4. Allowable loads may be linearly interpolated between concrete strengths listed. 5. Allowable loads for 14-inch size at 118-inch embedment apply to both the Wedge-All and Tie-Wire anchors. Installation torque does not apply to the Tie-Wire anchor. 6. The minimum concrete thickness is 112 times the embedment depth.
137
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13 for an explanation of the load table icons
(6.4)
8 (10.8)
(9.5)
30 (40.7)
(12.7)
60 (81.3)
(15.9)
90 (122.0)
Mechanical Anchors
(19.1)
150 (203.4)
(22.2)
200 (271.2)
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1 (25.4)
300 (406.7)
114 (31.8)
400 (542.3)
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for edge distance and spacing on pages 141 and 143. 3. Drill bit diameter used in base material corresponds to nominal anchor diameter. 4. Allowable loads may be linearly interpolated between concrete strengths listed. 5. The minimum concrete thickness is 112 times the embedment depth.
138
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13 for an explanation of the load table icons
(6.4)
8 (10.8)
(9.5)
30 (40.7)
(12.7)
60 (81.3)
(15.9)
90 (122.0)
Mechanical Anchors
(19.1)
150 (203.4)
(22.2)
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
200 (271.2)
1 (25.4)
300 (406.7)
114 (31.8)
400 (542.3)
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for spacing and edge distance on pages 141, 142 and 144. 3. Drill bit diameter used in base material corresponds to nominal anchor diameter. 4. Allowable loads may be linearly interpolated between concrete strengths listed. 5. The minimum concrete thickness is 112 times the embedment depth.
139
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Install. Torque ft-lbs (N-m)
*See page 13 for an explanation of the load table icons
WEDGE-ALL ANCHOR
Shear Loads for Carbon-Steel Wedge-All (and Tie-Wire) Anchors in Sand-Lightweight Concrete over Metal Deck
Shear Load Shear Load Embed. Critical Critical (Install in Concrete) (Install through Metal Deck) Depth Edge Spacing f'c 3000 psi (20.7 MPa) f'c 3000 psi (20.7 MPa) in. Dist. in. Concrete Concrete (mm) in. (mm) Ultimate Std. Dev. Allow. Ultimate Std. Dev. Allow. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 1 ( 338 234 1,660 627 415 4 TWD) 112 (38) (86) (70) (7.4) (2.8) (1.8) (6.4) 1 214 634 418 5,575 377 1,395 7,260 607 1,815 2 (57) (171) (105) (24.8) (1.7) (6.2) (32.3) (2.7) (8.1) (12.7) 5 234 838 5 8,900 742 2,225 8,560 114 2,140 8 (70) (213) (127) (39.6) (3.3) (9.9) (38.1) (0.5) (9.5) (15.9) 3 338 10 618 10,400 495 2,600 11,040 321 2,760 4 (86) (254) (156) (46.3) (2.2) (11.6) (49.1) (1.4) (12.3) (19.1) Size in. (mm)
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for edge distance on page 148. 3. 100% of the allowable load is permitted at critical spacing, loads at reduced spacing have not been determined. 4. Drill bit diameter used in base material corresponds to nominal anchor diameter.
*
Install. Torque ft-lbs (N-m)
412"
712"
Mechanical Anchors
5. The minimum concrete thickness is 112 times the embedment depth. 6. Metal deck must be minimum 20 gauge. 7. Anchors installed in the bottom flute of the steel deck must have a minimum allowable edge distance of 112" from the inclined edge of the bottom flute.
Tension and Shear Loads for Carbon-Steel Wedge-All Anchors in Grout-Filled CMU
Size Embed. Critical Critical Critical 8" Grout-Filled CMU Allowable Load Based on CMU Strength Install. in. Depth Edge End Spacing Torque Tension Load Shear Load (mm) in. Dist. Dist. in. ft-lbs (mm) in. in. (mm) Ultimate Std. Dev. Allow. Ultimate Std. Dev. Allow. (N-m) (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) Anchor Installed on the Face of the CMU Wall at Least 114 inch Away from Head Joint (See Figure) 3 258 1012 1012 1012 1,700 129 340 3,360 223 670 30 8 (267) (267) (267) (7.6) (0.6) (1.5) (14.9) (1.0) (3.0) (40.7) (9.5) (67) 1 312 14 14 14 2,120 129 425 5,360 617 1,070 35 2 (356) (356) (356) (9.4) (0.6) (1.9) (23.8) (2.7) (4.8) (47.4) (12.7) (89) 5 438 1712 1712 1712 3,120 342 625 8,180 513 1,635 55 8 (13.9) (1.5) (2.8) (36.4) (2.3) (7.3) (74.5) (15.9) (111) (445) (445) (445) 3 514 21 21 21 4,320 248 865 10,160 801 2,030 120 4 (19.2) (1.1) (3.8) (45.2) (3.6) (9.0) (162.6) (19.1) (133) (533) (533) (533)
1. The tabulated allowable loads are 3. Values for 8-inch wide concrete masonry units (CMU) based on a safety factor of 5.0 for with a minimum specified compressive strength of installations under the IBC and IRC. masonry, f'm, at 28 days is 1500 psi. 2. Listed loads may be applied to 4. Embedment depth is measured from the installations on the face of the outside face of the concrete masonry unit. 1 CMU wall at least 1 4 inch away 5. Drill bit diameter used in base material from headjoints. corresponds to nominal anchor diameter.
4" Minimum end distance Critical end distance (see load table) No installation within 1" of head joint
Shaded Area = Placement for Full and Reduced Allowable Load Capacity in Grout-Filled CMU
140
6. Allowable loads may be increased 3313 % for short-term loading due to wind and seismic forces. 7. Tension and shear loads for the Wedge-All anchor may be combined using the parabolic interaction equation (n=53). 8. Refer to allowable load-adjustment factors for edge distance on page 145.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
1
712 3 0.70
1 10 4 0.70
0.70 0.74 0.78 0.80 0.82 0.86 0.90 0.94 0.98 1.00
0.70 0.73 0.75 0.77 0.80 0.83 0.87 0.90 0.92 0.93 0.97 1.00
0.70 0.71 0.73 0.76 0.79 0.81 0.84 0.86 0.87 0.90 0.93 0.96 0.99 1.00
0.70 0.73 0.75 0.78 0.80 0.81 0.83 0.85 0.88 0.90 0.93 0.94 1.00
0.70 0.72 0.74 0.75 0.76 0.78 0.80 0.82 0.84 0.85 0.90 1.00
Mechanical Anchors
*
3
712 3 0.30
1 10 4 0.30
0.30 0.39 0.49 0.53 0.58 0.67 0.77 0.86 0.95 1.00
0.30 0.38 0.42 0.46 0.53 0.61 0.69 0.77 0.81 0.84 0.92 1.00
0.30 0.33 0.37 0.43 0.50 0.57 0.63 0.67 0.70 0.77 0.83 0.90 0.97 1.00
0.30 0.36 0.42 0.48 0.53 0.56 0.59 0.65 0.71 0.77 0.83 0.85 1.00
0.30 0.35 0.39 0.42 0.44 0.49 0.53 0.58 0.63 0.65 0.77 1.00
1. Cact = actual edge distance at which anchor is installed (inches). 2. Ccr = critical edge distance for 100% load (inches). 3. Cmin = minimum edge distance for reduced load (inches). 4. fc = adjustment factor for allowable load at actual edge distance. 5. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 6. fcmin = adjustment factor for allowable load at minimum edge distance. 7. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
Critical spacing is listed in the load tables. No adjustment in load is required when the anchors are spaced at critical spacing. No additional testing has been performed to determine the adjustment factors for spacing dimensions less than those listed in the load tables.
141
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Edge Distance Shear (fc||) (Shear Applied Parallel to Edge with End Distance EDmin)
Size Edge E Dist. EDmin Cact|| Ccr|| (in.) Cmin|| fcmin|| 1 112 2 212 3 312 4 5 6 7 8 9 10 11 12 13
1
*
5
338 1312 334 112 0.93 0.93 0.95 0.96 0.98 0.99 1.00
412 18 5 2 0.70
1 9 36 10 4 0.62
Mechanical Anchors
1. Table is not applicable to anchors with ED < EDmin. Factors from this table may not be combined with load-adjustment factors for shear loads applied perpendicular to edge. 2. Cact|| = actual edge distance (measured perpendicular to direction of shear load) at which anchor is installed (inches). 3. Ccr|| = critical edge distance (measured perpendicular to direction of shear load) for 100% load (inches). 4. Cmin|| = minimum edge distance (measured perpendicular to direction of shear load) for reduced load (inches). 5. ED = actual end distance (measured parallel to direction of shear load) at which anchor is installed (inches). 6. EDmin = minimum edge distance (measured parallel to direction of shear load). 7. fc|| = adjustment factor for allowable load at actual edge distance. 8. fccr|| = adjustment factor for allowable load at critical edge distance. fccr|| is always = 1.00. 9. fcmin|| = adjustment factor for allowable load at minimum edge distance. 10. fc|| = fcmin|| + [(1 - fcmin||) (Cact|| - Cmin||) / (Ccr|| - Cmin||)].
142
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
1
1 8 158
1
1 4 238
3
0.70 0.73 0.75 0.78 0.80 0.83 0.88 0.93 0.98 1.00
0.43 0.48 0.53 0.57 0.62 0.67 0.76 0.86 0.95 1.00
0.70 0.72 0.74 0.76 0.79 0.83 0.87 0.91 0.98 1.00
0.43 0.47 0.50 0.54 0.61 0.68 0.75 0.82 0.96 1.00
Mechanical Anchors
*
5 7 212 0.43 0.49 0.62 0.75 0.87 1.00
1 778 11 4 0.70 412 614 214 0.43 0.54 0.68 0.82 0.96 1.00 9 1258 412 0.70 558 778 278 0.43 0.46 0.57 0.68 0.79 0.90 1.00
0.71 0.74 0.78 0.81 0.85 0.89 0.92 0.96 0.99 1.00
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
143
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
1
Mechanical Anchors
1 8 158
1
1 4 238
3
0.79 0.81 0.83 0.84 0.86 0.88 0.91 0.95 0.98 1.00
0.79 0.81 0.83 0.84 0.86 0.88 0.91 0.95 0.98 1.00
0.79 0.80 0.82 0.83 0.86 0.88 0.91 0.93 0.99 1.00
0.79 0.80 0.82 0.83 0.86 0.88 0.91 0.93 0.99 1.00
1 778 11 4 0.79 412 614 214 0.79 0.83 0.88 0.93 0.99 1.00 9 1258 412 0.79 558 778 278 0.79 0.80 0.84 0.88 0.92 0.96 1.00
0.80 0.82 0.85 0.87 0.90 0.92 0.94 0.97 0.99 1.00
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
144
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
* 2
5
338 138 0.70 0.70 0.72 0.79 0.87 0.91 0.94 1.00
10 4 0.70
0.70 0.72 0.75 0.76 0.79 0.83 0.87 0.91 0.94 0.98 1.00
0.70 0.71 0.74 0.77 0.80 0.83 0.86 0.89 0.90 0.92 0.95 0.98 1.00
338 138 0.30 0.30 0.34 0.52 0.69 0.78 0.87 1.00
10 4 0.30
*
*See page 13 for an explanation of the load table icons
0.70 0.73 0.75 0.78 0.80 0.83 0.84 0.85 0.88 0.90 0.92 0.93 0.95 0.98 1.00
0.30 0.34 0.41 0.43 0.52 0.61 0.69 0.78 0.87 0.96 1.00
0.30 0.32 0.39 0.46 0.53 0.60 0.67 0.74 0.77 0.81 0.88 0.95 1.00
0.30 0.36 0.42 0.48 0.53 0.59 0.62 0.65 0.71 0.77 0.81 0.83 0.88 0.94 1.00
Mechanical Anchors
Load-Adjustment Factors for Carbon-Steel Wedge-All Anchors in Face of Wall Installation in 8" Grout-Filled CMU: Edge Distance, Tension and Shear Loads Edge Distance Tension (fc)
Edge Dist. Cact (in.) 4 6 8 10 12 14 16 18 20 Size Ccr Cmin fcmin
3
* 2
5
*
1
20 4 0.80 0.80 0.83 0.85 0.88 0.90 0.93 0.95 0.98 1.00
20 4 0.80 0.80 0.83 0.85 0.88 0.90 0.93 0.95 0.98 1.00
12 4 0.79 0.79 0.82 0.84 0.87 0.90 0.92 0.95 0.97 1.00
12 4 0.52 0.52 0.58 0.64 0.70 0.76 0.82 0.88 0.94 1.00
Critical spacing is listed in the load tables. No adjustment in load is required when the anchors are spaced at critical spacing. No additional testing has been performed to determine the adjustment factors for spacing dimensions less than those listed in the load tables.
20 4 0.32 0.32 0.36 0.41 0.45 0.49 0.53 0.58 0.62 0.66 0.70 0.75 0.79 0.83 0.87 0.92 0.96 1.00
20 4 0.32 0.32 0.36 0.41 0.45 0.49 0.53 0.58 0.62 0.66 0.70 0.75 0.79 0.83 0.87 0.92 0.96 1.00
1. Cact = actual edge distance at which anchor is installed (inches). 2. Ccr = critical edge distance for 100% load (inches). 3. Cmin = minimum edge distance for reduced load (inches). 4. fc = adjustment factor for allowable load at actual edge distance. 5. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 6. fcmin = adjustment factor for allowable load at minimum edge distance. 7. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
145
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SLEEVE-ALL ANCHORS
Acorn
Hex
Mechanical Anchors
SUGGESTED SPECIFICATIONS: Sleeve anchors shall be zinc plated studs having a minimum 50,000 psi tensile strength with an expansion sleeve meeting AISI 1008 cold rolled steel or type 304 stainless steel stud with a type 304 stainless-steel expansion sleeve, as called for on the drawings. Sleeve anchors shall meet Federal Specications A-A-1922A. Anchors shall be Sleeve-All expanding sleeve anchors from Simpson Strong-Tie, Pleasanton, CA. Anchors shall be installed following the Simpson Strong-Tie instructions for Sleeve-All expanding sleeve anchors.
Round
Rod Coupler
Material Specifications
Anchor Component Zinc Plated Carbon Steel 304 Stainless Steel Type 304 Type 304 Type 304 Type 304
16
8 8 2 2
8 8 4 4
Anchor Body Material meets minimum 50,000 psi tensile Sleeve SAE J403, Grade 1008 Cold Rolled Steel Commercial Grade, meets requirements Nut of ASTM A563 Grade A SAE J403, Grade 1008/1010 Washer Cold Rolled Steel
1 3
4 8
16 16
3 1 1
1 9
2 16 8
3 15
3 3
4 16
Length Identification Head Marks on Sleeve-All Anchors (corresponds to length of anchor inches).
Mark From Up To But Not Including A 1 2
1
B 2 212
C 2 2
1
D 3 312
E 3 2
1
F 4 412
G 4 2
1
H 5 512
I 5 2
1
J 6 612
K 6 2
1
L 7 712
M 7 2
1
N 8 812
O 8 2
1
P 9 912
Q 9 2
1
R 10 11
S 11 12
T 12 13
U 13 14
V 14 15
W 15 16
X 16 17
Y 17 18
Z 18 19
10
146
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No. SL25138A SL25214A SL31112H SL31212H SL37178H SL37300H SL37400H SL50214H SL50300H SL50400H SL50600H SL62214H SL62300H SL62414H SL62600H SL75212H SL75414H SL75614H SL25200PF SL25300PF SL31212PF SL31312PF SL37234PF SL37400PF SL37500PF SL37600PF SL25200R SL25234R SL37212R SL37334R SL37434R
Head Bolt Max. Quantity Style Diameter - Fixture Threads Thickness Box Ctn. per inch (in.) 1 4 100 500 Acorn 3 16 - 24 Head 118 100 500 3 8 100 500 1 4 - 20 1116 50 250 3 8 50 250 5 16 - 18 112 50 200 214 50 200 1 2 50 200 3 4 25 100 3 8 - 16 134 25 100 Hex Head 338 20 80 1 2 25 100 3 4 20 80 1 2 - 13 112 10 40 314 10 40 1 2 10 40 5 7 8 - 11 8 10 40 278 5 20 7 8 100 500 3 16 - 24 178 50 250 1116 50 250 1 4 - 20 Phillips 2116 50 250 Flat 1 1 4 50 200 Head 212 50 200 5 16 - 18 312 50 200 412 50 200 7 8 100 500 3 16 - 24 158 50 250 Round 1 50 200 Head 5 16 - 18 214 50 200 314 50 200
4 x 2 4 8 x 178 3 8 x 3 1 2 x 3 1 2 x 4
1
Bolt Max. Diameter - Fixture Threads Thickness per inch (in.) Phillips Flat Head 316 - 24 118 3 8 5 16 - 18 112 Hex 3 Head 4 3 8 - 16 134
Head Style
Sleeve-All Anchor (with rod coupler) Product Data - Zinc-Plated Carbon Steel
Size (in.)
3 1
8 x 1 8 2 x 214 5 8 x 214
7
Wrench Size
1
2 8 3 4
Mechanical Anchors
*These models do not meet minimum embedment requirements for rated load values. C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Tension and Shear Loads for 38" Sleeve-All Anchor in Grout-Filled CMU (Anchor Installed in Horizontal Mortar Joint or Face Shell)
Size Embed. Min. Edge Min. End Min. Install. Tension Load Shear Load in. Depth Dist. Dist. Spacing Torque (mm) in. in. in. in. Ultimate Allow. Ultimate Allow. ft-lbs (mm) (mm) (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) (N-m)
3
1"
(9.5)
112 (38)
16 (406)
16 (406)
24 (610)
2,000 (8.9)
400 (1.8)
2,300 (10.2)
460 (2.0)
15 (20)
End Distance specified in table 1" Block
1. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the *See page 13 for an IBC and IRC. explanation of the 2. Listed loads may be applied to installations through a face shell with the load table icons following placement guidelines: a. Minimum 3" from vertical mortar joint. b. Minimum 1" from vertical cell centerline. 3. Values for 8-inch wide concrete masonry units (CMU) with a minimum specified compressive strength of masonry, f'm, at 28 days is 1500 psi. 4. Embedment depth is measured from the outside face of the concrete masonry unit. 5. Drill bit diameter used in base material corresponds to nominal anchor diameter. 6. Allowable loads may not be increased for short-term loading due to wind or seismic forces.
3"
3"
1" Block
147
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Shear Load f'c 2000 psi (13.8 MPa) Concrete Ultimate Std. Dev. Allow. lbs. (kN) lbs. (kN) lbs. (kN) 1,440 90 360 (6.4) (0.4) (1.6) 2,160 113 540 (9.6) (0.5) (2.4) 3,080 223 770 (13.7) (1.0) (3.4) 5,000 473 1,250 (22.2) (2.1) (5.6) 8,520 713 2,130 (37.9) (3.2) (9.5) 10,040 955 2,510 (44.7) (4.2) (11.2) Install. Torque ft-lbs (N-m) 5 (7) 8 (11) 15 (20) 25 (34) 50 (68) 90 (122)
Mechanical Anchors
Embed. Min. Edge Min. End Min. Install. *See page 13 for an Tension Load Shear Load Depth Dist. Dist. Spacing Torque explanation of the load table icons in. in. in. in. Ultimate Allow. Ultimate Allow. ft-lbs lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) (mm) (mm) (mm) (mm) (N-m) 112 (38) 214 (57) 234 (70) 338 (86) 112 (38) 214 (57) 234 (70) 338 (86) 12 (305) 12 (305) 12 (305) 12 (305) 8 (203) 8 (203) 8 (203) 8 (203) Anchor Installed in a Single Face Shell 12 24 1,746 350 (305) (610) (7.8) (1.6) 12 24 3,384 675 (305) (610) (15.1) (3.0) 12 24 3,970 795 (305) (610) (17.7) (3.5) 12 24 6,395 1,280 (305) (610) (28.4) (5.7) Anchor Installed in Mortar T Joint 8 24 1,927 385 (203) (610) (8.6) (1.7) 8 24 3,849 770 (203) (610) (17.1) (3.4) 8 24 4,625 925 (203) (610) (20.6) (4.1) 8 24 5,483 1,095 (203) (610) (24.4) (4.9) 2,871 (12.8) 5,670 (25.2) 8,171 (36.3) 12,386 (55.1) 3,436 (15.3) 5,856 (26.0) 7,040 (31.3) 7,869 (35.0) 575 (2.6) 1,135 (5.0) 1,635 (7.3) 2,475 (11.0) 685 (3.0) 1,170 (5.2) 1,410 (6.3) 1,575 (7.0) 15 (20) 25 (34) 50 (68) 90 (122) 15 (20) 25 (34) 50 (68) 90 (122)
3 1
(9.5) (12.7)
5
(15.9)
3
8 4
1"
(19.1)
3 1
(9.5) (12.7)
5
3"
3"
(15.9)
3
8 4
1" Block
(19.1)
1. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 2. Listed loads may be applied to installations through a face shell with the following placement guidelines: a. Minimum 3" from vertical mortar joint. b. Minimum 1" from vertical cell centerline. 3. Values for 6- and 8-inch wide concrete masonry units (CMU) with a minimum specified compressive strength of masonry, f'm, at 28 days is 1500 psi. 4. Embedment depth is measured from the outside face of the concrete masonry unit. 5. Drill bit diameter used in base material corresponds to nominal anchor diameter. 6. Allowable loads may not be increased for short-term loading due to wind or seismic forces.
148
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
3
*
5
16
5 212 0.60
118 412 214 0.50 0.50 0.56 0.64 0.67 0.78 0.89 1.00
1716 534 278 0.50 0.50 0.52 0.61 0.70 0.78 0.87 0.96 1.00
16
112 6 3 0.50
0.60 0.63 0.68 0.73 0.79 0.84 0.87 0.89 0.95 1.00
0.50 0.56 0.61 0.64 0.67 0.72 0.75 0.78 0.89 1.00
0.50 0.52 0.55 0.59 0.61 0.64 0.73 0.82 0.91 1.00
*
3
Mechanical Anchors
16
5 212 0.30
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
0.30 0.35 0.44 0.53 0.63 0.72 0.77 0.81 0.91 1.00
1. Cact = actual edge distance at which anchor is installed (inches). 2. Ccr = critical edge distance for 100% load (inches). 3. Cmin = minimum edge distance for reduced load (inches). 4. fc = adjustment factor for allowable load at actual edge distance. 5. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 6. fcmin = adjustment factor for allowable load at minimum edge distance. 7. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
149
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Drop-In
Lipped Drop-In
Short Drop-In
Coil-Thread Drop-In
Mechanical Anchors
Installation Sequence
1/8 min.
"
1/8 min.
"
1. Drill a hole using the specified diameter carbide bit into the base material to a depth of at least 18" deeper than the required embedment. Then blow the hole clean of dust and debris using compressed air.
1/8 min.
2. Insert Drop-In anchor into hole. Tap with hammer until flush against surface.
"
1/8 min.
"
Material Specifications
Anchor Component Anchor Body Expander Plug Thread Component Material Zinc Plated Carbon Steel Meets minimum 70,000 psi tensile Meets minimum 50,000 psi tensile UNC/Coil-thread Type 303 Stainless Steel AISI 303. Meets chemical requirements of ASTM A-582 AISI 303 UNC Type 316 Stainless Steel Type 316 Type 316 UNC 3. Using the Drop-In anchor setting tool, drive expander plug toward the bottom of the anchor until the shoulder of setting tool makes contact with the top of the anchor. 4. Install threaded rod into the anchor to support pipes, wiring, etc.
Note: DIA37S, DIA50C and DIA75C are not available in stainless steel.
150
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
4 8 1 2 5 8 3 4
1 3
8 2 5 8 7 8
1
20 16 13 11 10
8 8 3 4 1 114
3 5
100 50 50 25 20
Drop-In Anchor
4 3 8 1 2
1
8 1 2 5 8
3
20 16 13
1 112 2
8 5 8 3 4
Mechanical Anchors
8 2
DIA50S 1
16
1. A dedicated setting tool is included with each box of DIA37S and DIA50S.
Drill Bit Bolt Body Thread Quantity Diameter Threads Length Length Box Ctn. (in.) (per in.) (in.) (in.)
5
2 4
6 5
2 318
4 114
3
50 20
200 80
1. DIA50C and DIA75C accept 12" and 34" coil-thread rod, respectively.
2 8
16
1 1 4
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Embed. Depth in. (mm) 1 (25) 112 (38) 2 (51) 212 (64) 318 (79)
Critical Edge Dist. in. (mm) 3 (76) 412 (114) 6 (152) 712 (191) 9 (229)
Tension Load Critical f'c 2000 psi f'c 3000 psi Spacing (13.8 MPa) Concrete (20.7 MPa) Concrete in. Ultimate Std. Dev. Allowable Allowable (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 4 (102) 6 (152) 8 (203) 10 (254) 1212 (318) 1,400 (6.2) 2,400 (10.7) 3,320 (14.8) 5,040 (22.4) 8,160 (36.3) 201 (0.9) 251 (1.1) 372 (1.7) 689 (3.1) 961 (4.3) 350 (1.6) 600 (2.7) 830 (3.7) 1,260 (5.6) 2,040 (9.1) 405 (1.8) 795 (3.5) 1,178 (5.2) 1,715 (7.6) 2,365 (10.5)
f'c 4000 psi (27.6 MPa) Concrete Ultimate Std. Dev. Allowable lbs. (kN) lbs. (kN) lbs. (kN) 1,840 (8.2) 3,960 (17.6) 6,100 (27.1) 8,680 (38.6) 10,760 (47.9) 451 (2.0) 367 (1.6) 422 (1.9) 971 (4.3) 1,696 (7.5) 460 (2.0) 990 (4.4) 1,525 (6.8) 2,170 (9.7) 2,690 (12.0)
8 2
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for edge distance and spacing on page 155. 3. Allowable loads may be linearly interpolated between concrete strengths listed. 4. The minimum concrete thickness is 112 times the embedment depth.
Shear Loads for Drop-In (Carbon and Stainless Steel), Lipped Drop-In (Carbon Steel) and Coil-Thread Drop-In (Carbon Steel) Anchors in Normal-Weight Concrete
Rod Size in. (mm)
1 4 (6.4) 3 8 (9.5) 1 2 (12.7) 5 8 (15.9) 3 4 (19.1)
Mechanical Anchors
Embed. Depth in. (mm) 1 (25) 112 (38) 2 (51) 212 (64) 318 (79)
Critical Edge Dist. in. (mm) 312 (89) 514 (133) 7 (178) 834 (222) 1012 (267)
Critical Spacing in. (mm) 4 (102) 6 (152) 8 (203) 10 (254) 1212 (318)
Shear Load f'c 2000 psi (13.8 MPa) Concrete Ultimate lbs. (kN) 1,960 (8.7) 3,240 (14.4) 7,000 (31.1) 11,080 (49.3) 13,800 (61.4) Std. Dev. lbs. (kN) 178 (0.8) 351 (1.6) 562 (2.5) 923 (4.1) 1,781 (7.9) Allowable lbs. (kN) 490 (2.2) 810 (3.6) 1,750 (7.8) 2,770 (12.3) 3,450 (15.3) f'c 3000 psi (20.7 MPa) Concrete Allowable lbs. (kN) 490 (2.2) 925 (4.1) 1,750 (7.8) 2,770 (12.3) 3,725 (16.6) f'c 4000 psi (27.6 MPa) Concrete Allowable lbs. (kN) 490 (2.2) 1,040 (4.6) 1,750 (7.8) 2,770 (12.3) 4,000 (17.8)
8 2
1. The allowable loads listed are based on a safety factor of 4.0. 2. Refer to allowable load-adjustment factors for edge distance and spacing on page 155.
3. Allowable loads may be linearly interpolated between concrete strengths listed. 4. The minimum concrete thickness is 112 times the embedment depth.
152
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
614" 3" Min. 20 gauge steel deck Drop-in anchor 412" Upper ute min. 412" 712"
Mechanical Anchors
Tension and Shear Loads for 38" and 12" Short Drop-In Anchor in Sand-Lightweight Concrete Fill over Metal Deck
Model No. Rod Size (in.)
3 1
*
Install through the Lower Flute or Upper Flute of Metal Deck, f'c 3000 psi Concrete Tension Load Ultimate (lbs.) 1344 1711 Allowable (lbs.) 335 430 Shear Load Ultimate (lbs.) 1649 2070 Allowable (lbs.) 410 515
DIA37S DIA50S
2 8
1. The allowable loads listed are based on a safety factor of 4.0. 2. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 3. Refer to allowable load-adjustment factors for edge distances and spacing on page 156. 4. Anchors were installed with a 1" offset from the centerline of the flute.
614" 3" Min. 20 gauge steel deck Drop-in anchor 1" offset see footnote #4 on bottom table Upper ute Min. 412" 412" 712"
153
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Tension Shear Normal-Weight Concrete, f'c 2500 psi Normal-Weight Concrete, f'c 4000 psi Drill Emb. Critical Critical Critical Bit Tension Load Shear Load Tension Load Shear Load Depth Edge Edge Spacing Dia. (in.) Distance Distance (in.) Ultimate Allowable Ultimate Allowable Ultimate Allowable Ultimate Allowable (in.) (in.) (in.) (lbs.) (lbs.) (lbs.) (lbs.) (lbs.) (lbs.) (lbs.) (lbs.)
1
2 8
1 4 2
1 5 4
3 4
1,500 2,039
375 510
2,274 3,224
570 805
2,170 3,420
540 855
3,482 5,173
870 1,295
1. The allowable loads listed are based on a safety factor of 4.0. 2. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 3. Refer to allowable load-adjustment factors for edge distances and spacing on page 155. 4. Allowable loads may be linearly interpolated between concrete strengths. 5. The minimum concrete thickness is 112 times the embedment depth.
Tension and Shear Loads for 38" and 12" Short Drop-In Anchor in Hollow Core Concrete Panel
Model No. DIA37S DIA50S Rod Size (in.)
3 1
Hollow Core Concrete Panel, f'c 4000 psi Tension Load Ultimate (lbs.) 1,860 2,650 Allowable (lbs.) 465 660 Shear Load Ultimate (lbs.) 3,308 4,950 Allowable (lbs.) 825 1,235
*See page 13 for an explanation of the load table icons
2 8
1. The allowable loads listed are based on a safety factor of 4.0. 2. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 3. Refer to allowable load-adjustment factors for edge distances and spacing on page 155. 4. Allowable loads may be linearly interpolated between concrete strengths.
Mechanical Anchors
Hollow Core Concrete Panel (Anchor can be installed below web or hollow core)
154
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
1
*
3 9 8 3 4
4 2 258 0.65
1
6 312 0.65
7 2 438 0.65
1
9 514 0.65
1 2 6 3 0.50
1
2 8 4 0.50
2 2 10 5 0.50
1
Mechanical Anchors
*
3
Edge Dist. Cact (in.) 134 2 212 258 3 312 4 438 412 5 514 512 6 612 7 712 8 812 834 9 912 10 1012
5 4 258 0.45
1
7 312 0.45
8 4 438 0.45
3
1. E = Embedment depth (inches). 2. Sact = actual spacing distance at which anchors are installed (inches). 3. Scr = critical spacing distance for 100% load (inches). 4. Smin = minimum spacing distance for reduced load (inches). 5. fs = adjustment factor for allowable load at actual spacing distance. 6. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 7. fsmin = adjustment factor for allowable load at minimum spacing distance. 8. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)]. 9. 38" Short Drop-In (DIA37S).
0.45 0.53 0.59 0.61 0.69 0.73 0.76 0.84 0.92 1.00
0.45 0.47 0.53 0.56 0.59 0.65 0.72 0.78 0.84 0.91 0.97 1.00
0.45 0.48 0.53 0.58 0.63 0.69 0.74 0.79 0.82 0.84 0.90 0.95 1.00
1. Cact = actual edge distance at which anchor is installed (inches). 2. Ccr = critical edge distance for 100% load (inches). 3. Cmin = minimum edge distance for reduced load (inches). 4. fc = adjustment factor for allowable load at actual edge distance. 5. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 6. fcmin = adjustment factor for allowable load at minimum edge distance. 7. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
155
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
8 434 0.65
*
*See page 13 for an explanation of the load table icons
Mechanical Anchors
Size Sact Scr (in.) Smin fsmin 4 412 5 514 6 612 7 712 8 812 9 912 10 1058
8 4 0.50 0.50 0.56 0.63 0.66 0.75 0.81 0.88 0.94 1.00
10 8 514 0.50
5
0.50 0.57 0.62 0.66 0.71 0.76 0.80 0.85 0.90 0.94 1.00
0.45 0.48 0.54 0.60 0.66 0.72 0.78 0.84 0.90 0.96 1.00
1. Cact = actual edge distance at which anchor is installed (inches). 2. Ccr = critical edge distance for 100% load (inches). 3. Cmin = minimum edge distance for reduced load (inches). 4. fc = adjustment factor for allowable load at actual edge distance. 5. fccr = adjustment factor for allowable load at critical edge distance. fccr is always = 1.00. 6. fcmin = adjustment factor for allowable load at minimum edge distance. 7. fc = fcmin + [(1 - fcmin) (Cact - Cmin) / (Ccr - Cmin)].
156
7 312 0.45 0.45 0.53 0.61 0.65 0.69 0.76 0.84 0.92 1.00
1. Sact = actual spacing distance at which anchors are installed (inches). 2. Scr = critical spacing distance for 100% load (inches). 3. Smin = minimum spacing distance for reduced load (inches). 4. fs = adjustment factor for allowable load at actual spacing distance. 5. fscr = adjustment factor for allowable load at critical spacing distance. fscr is always = 1.00. 6. fsmin = adjustment factor for allowable load at minimum spacing distance. 7. fs = fsmin + [(1 - fsmin) (Sact - Smin) / (Scr - Smin)].
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Mechanical Anchors
1 1 3
N/A
34
"
58
"
12
Multiple rod diameters are easily accommodated with the Blue Banger Hanger.
157
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
BLUE BANGER HANGER METAL-ROOF DECK INSERT FEATURES: Low profile design doesn't interfere with roofing material Plastic sleeve allows for easy identification and keeps internal threads clean. Positive attachment to the roof deck prevents spinning and keeps the hanger in position. Pre-staked screws allow quick installation. Multi-thread design: The insert accepts 3 rod diameters. INSTALLATION: Drill a hole in the metal deck using the appropriate diameter bit as referenced in the table. Insert the hanger into the hole and fasten to the deck with the two pre-staked, self-drilling sheet metal screws provided.
Mechanical Anchors
BLUE BANGER HANGER WOOD-FORM INSERT FEATURES: Blue plastic ring acts as an insert locator when forms are removed. Plastic ring creates a countersunk recess to keep internal threads clean from concrete residue. Nails snap off with the swipe of a hammer after the forms are removed. Multi-thread design: Each insert accepts 23 rod diameters. INSTALLATION: Strike the top of the hanger and drive the 3 mounting nails into the forming material until the bottom of the hanger is flush with the plywood. The hanger should be sitting 90 perpendicular to the forming material. Once concrete is hardened, and forms are stripped, strike the mounting nails to break them off.
158
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Roof-Deck Insert: Tension Loads in Metal Deck
Tension Load Based Tension Load Based Min. Threaded Allowable Tension Min. on Concrete Strength on Rod Strength Threaded Embed. Drill Bit Edge Load lbs. (kN) Model Rod Spacing Model Rod Depth f'c 3000 psi Dia. Dist. A307 (SAE 1018) No. Dia. in. (20.7 MPa) Concrete No. Dia. in. in. 112" Deck 3" Deck in. in. (mm) Ultimate Allowable in. (mm) Allowable (mm) 1 4 lbs. (kN) lbs. (kN) lbs. (kN) 150 300 13 7 3 BBRD2550 16- 8 8 940 1 (0.7) (1.3) 4 1 (4.2) 2 2 7 8 6,820 1,705 2,105 1. The allowable loads are based on a factor of safety of 4.0. 3 BBWF2550 8 (51) (178) (203) (30.3) (7.6) (9.4) 2. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 3,750 1 2 3. Acceptability of deck deflection due to imposed loads (16.7) must be investigated separately. 2,105 3 4. Threaded-rod strength must be investigated separately. 8 (9.4) 5. Anchors may be installed in the top or bottom flute of the metal deck. 2 7 8 7,360 1,840 3,750 1 BBWF3762 2 6. Deck shall be 20-gauge minimum. (51) (178) (203) (32.7) (8.2) (16.7) 5,875 5 8 (26.1) 5,875 5 8 (26.1) 2 7 8 7,420 1,855 BBWF6275 (51) (178) (203) (33.0) (8.3) 8,460 3 4 (37.6) See Notes Below
Shear Load Based Shear Load Based Min. Typical Roof-Deck Insert Installation in Metal Deck Min. on Concrete Strength on Rod Strength Threaded Embed. Edge Spacing Model Rod Depth f' 3000 psi c Dist. in. (20.7 MPa) Concrete A307 (SAE 1018) No. Dia. in. in. See table (mm) Ultimate Allowable in. (mm) Allowable (mm) lbs. (kN) lbs. (kN) lbs. (kN) 2 7 8 8,750 2,185 1,930 1 BBWF2550 2 (51) (178) (203) (38.9) (9.7) (8.6) 2 7 8 10,700 2,675 3,025 5 BBWF3762 8 (51) (178) (203) (47.6) (11.9) (13.4) 2 7 8 10,460 2,615 4,360 3 BBWF6275 4 (51) (178) (203) (46.5) (11.6) (19.4) See Notes Below
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Mechanical Anchors
*
*See page 13 for an explanation of the load table icons
1. Allowable load must be the lesser of the concrete or steel strength. 2. The allowable loads based on concrete strength are based on a factor of safety of 4.0. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 4. Mechanical and plumbing design codes may prescribe lower allowable loads. Verify with local codes. 5. Minimum concrete slab thickness = 2x embedment depth.
159
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
*See page 13
Model No.
BBMD2550
BBMD3762
BBMD6275
Tension Load Based Tension Load Based Tension Load Based for an on Concrete Strength on Concrete Strength explanation Min. on Rod Strength Min. (Install in High Flute) (Install in Low Flute) Threaded Embed. of the load Edge Drill Bit Spacing Rod Depth table icons Dist. Dia. f'c 3000 psi f'c 3000 psi in. Dia. in. A307 (SAE 1018) in. in. (20.7 MPa) Concrete (20.7 MPa) Concrete (mm) in. (mm) (mm) Ultimate Allowable Ultimate Allowable Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 940 1 4 (4.2) 2 712 8 9,320 2,330 3,210 800 2,105 13 3 16- 78 8 (51) (191) (203) (41.5) (10.4) (14.3) (3.6) (9.4) 3,750 1 2 (16.7) 2,105 3 8 (9.4) 2 712 8 10,540 2,635 3,440 860 3,750 1 3 1 1 8-1 8 2 (51) (191) (203) (46.9) (11.7) (15.3) (3.8) (16.7) 5,875 5 8 (26.1) 5,875 5 8 (26.1) 2 712 8 12,360 3,090 3,445 860 3 3 1 16-1 8 (51) (191) (203) (55.0) (13.7) (15.3) (3.8) 8,460 3 See notes 4 (37.6) below.
Metal Deck Insert: Shear Loads in Normal-Weight or Sand-Lightweight Concrete over Metal Deck
Min. Min. Threaded Embed. Edge Spacing Rod Depth Dist. f'c 3000 psi f'c 3000 psi in. Dia. in. in. (20.7 MPa) Concrete (20.7 MPa) Concrete (mm) in. (mm) (mm) Ultimate Allowable Ultimate Allowable lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 2 712 8 9,720 2,430 2,790 700 1 2 (51) (191) (203) (43.2) (10.8) (12.4) (3.1) 2 712 8 9,400 2,350 3,360 840 5 8 (51) (191) (203) (41.8) (10.4) (14.9) (3.7) 2 712 8 9,720 2,430 3,360 840 3 4 (51) (191) (203) (43.2) (10.8) (14.9) (3.7) Shear Load Based Shear Load Based on Concrete Strength on Concrete Strength (Install in High Flute) (Install in Low Flute) Shear Load Based on Rod Strength A307 (SAE 1018) Allowable lbs. (kN) 1,930 (8.6) 3,025 (13.4) 4,360 (19.4)
*
*See page 13 for an explanation of the load table icons
Mechanical Anchors
Model No.
13
16- 78
1316-138
1. Allowable load must be the lesser of the concrete or rod strength. 2. The allowable loads based on concrete strength are based on a factor of safety of 4.0. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 4. Anchors may be installed off-center in the flute, up to 1" from the edge of flute. 5. Shear loads shall be applied flush with metal deck surface. 6. Deck shall be 20-gauge minimum. 7. Mechanical and plumbing design codes may prescribe lower allowable loads. Verify with local codes.
MIN. MIN.
712"
Wood Form Insert: Factory Mutual and Underwriters Laboratories Pipe Size Limits
Model No. FM UL Rod Max. Nominal Max. Nominal Dia. Pipe Size Pipe Size in. in. in.
Metal Deck Insert: Factory Mutual and Underwriters Laboratories Pipe Size Limits
Model No. Rod Dia. in. FM Max. Nominal Pipe Size Install in High Flute in. N/L 4 8 4 8 N/L 12 12 Install in Low Flute in. N/L 4 N/L 4 N/L N/L N/L N/L UL Max. Nominal Pipe Size Install in High Flute in. 4 4 8 4 8 8 12 12 Install in Low Flute in. 4 4 4 4 4 4 N/L N/L
BBWF2550
4 8 1 2 3 8 1 2 5 8 5 8 3 4
1 3
4 4 8 4 8 8
BBMD2550
BBMD3762 BBMD6275
4 8 1 2 3 8 1 2 5 8 5 8 3 4
1 3
118-138
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Easy-Set (EZAC)
Installation Sequence
Min. Box Carton Thread Length Qty. Qty. (in.)
5 3
Model No. EZAC25134 EZAC25238 EZAC31234 EZAC37238 EZAC37312 EZAC37434 EZAC50234 EZAC50312 EZAC50434 EZAC50600 EZAC62400 EZAC62434 EZAC62600 EZAC75500 EZAC75600 EZAC75712
8 4
100 100 50 50 50 50 25 25 25 25 15 15 15 10 10 10
500 500 250 250 250 200 125 125 100 100 60 60 60 40 40 20
Mechanical Anchors
*
*See page 13 for an explanation of the load table icons
1. The allowable loads listed are based on a safety factor of 4.0. 2. Allowable loads may not be increased for short-term loading due to wind or seismic forces. 3. 100% of the allowable load is permitted at critical spacing and critical edge distance. Allowable loads at lesser spacings and edge distances have not been determined. 4. The minimum concrete thickness is 112 times the embedment depth. 5. Tension and Shear loads for the EZAC Anchor may be combined using the straight-line interaction equation (n = 1).
161
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Installation Sequence
Mechanical Anchors
112" max
*
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
(4.8) (4.8)
1 1
16 16 4 4
5 5
32 32 16 16
(6.4) (6.4)
3 3
1. Maximum anchor embedment is 112" (38.1 mm). 2. Concrete must be minimum 1.5 x embedment.
Titen Tension and Shear Load Values in Face Shell of Hollow and Grout-Filled CMU
*
*See page 13 for
an explanation Values for 6" or 8" Lightweight, Titen Drill Bit Embed. Critical Critical of the load table Dia. Dia. Depth Spacing Edge Medium-Weight or Normal-Weight CMU icons in. in. in. in. Dist. Tension Load Shear Load (mm) (mm) (mm) in. Avg. Ult. Allow. Avg. Ult. Allow. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 3 1 214 118 542 110 1,016 205 16 5 32 (25.4) (57.2) (28.6) (2.4) (0.5) (4.5) (0.9) (4.8) 1 1 3 112 740 150 1,242 250 4 3 16 (25.4) (76.2) (38.1) (3.3) (0.7) (5.5) (1.1) (6.4) 1. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 2. Maximum anchor embedment is 112" (38.1 mm).
162
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No.1 TTN18114H TTN18134H TTN18214H TTN18234H TTN18314H TTN18334H TTN18400H TTN18114PF TTN18134PF TTN18214PF TTN18234PF TTN18314PF TTN18334PF TTN18400PF
Quantity Bit Diameter 2 Box Carton 3 Bulk 4 (in.) 1600 500 500 500 400 400 400 1600 500 500 500 400 400 400
Model No.1 TTN25114H TTN25134H TTN25214H TTN25234H TTN25314H TTN25334H TTN25400H TTN25500H TTN25600H TTN25114PF TTN25134PF TTN25214PF TTN25234PF TTN25314PF TTN25334PF TTN25400PF TTN25500PF TTN25600PF
Quantity Bit Diameter 2 Box Carton 3 Bulk 4 (in.) 1600 500 500 500 400 400 400 400 400 1600 500 500 500 400 400 400 400 400 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
32
100
1000
16
100
1. H Suffix: Hex Head, PF Suffix: Phillips Flat Head. 2. One drill bit is included in each box. 3. Cartons consist of boxes of 100. 4. Bulk Titen Screws come packed in a single carton, and do not include a drill bit. To order, add a B onto the end of the model number. Example: TTN18314HB.
1. H Suffix: Hex Head, PF Suffix: Phillips Flat Head. 2. One drill bit is included in each box. 3. Cartons consist of boxes of 100. 4. Bulk Titen Screws come packed in a single carton, and do not include a drill bit. To order, add a B onto the end of the model number. Example: TTN25314HB.
Mechanical Anchors
Model No. TTNW18114PF TTNW18134PF TTNW18214PF TTNW18234PF TTNW18314PF TTNW18334PF TTNW18400PF TTNW25114PF TTNW25134PF TTNW25214PF TTNW25234PF TTNW25314PF TTNW25334PF TTNW25400PF TTNW25500PF TTNW25600PF
Quantity Bit Diameter Box 1 Carton 2 Bulk 3 (in.) 1600 500 500 500 400 400 400 1600 500 500 500 400 400 400 400 400
16 x 114 16 x 134 3 16 x 214 3 16 x 234 3 16 x 314 3 16 x 334 3 16 x 4 1 4 x 114 1 4 x 134 1 4 x 214 1 4 x 234 1 4 x 314 1 4 x 334 1 4 x 4 1 4 x 5 1 4 x 6
3 3
32
100
1000
16
100
1. H Suffix: Hex Head, PF Suffix: Phillips Flat Head. 2. One drill bit is included in each box. 3. Cartons consist of boxes of 100. 4. Bulk Titen Screws come packed in a single carton, and do not include a drill bit. To order, add a B onto the end of the model number. Example: TTNW18314PFB.
163
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Installation Sequence
Mechanical Anchors
Position fixture, insert screw and tighten using drill and Titen screw installation tool fitted with a hex socket or phillips bit. For contact with preservative-treated wood and untreated wood, reference the table on page 12. Use caution not to damage coating during installation. The type 410 stainless-steel Titen with a protective top coat provides "medium" corrosion protection. Recommendations are based on testing and experience at time of publication and may change. Simpson Strong-Tie cannot provide estimates on service life of screws. Contact Simpson Strong-Tie for additional information.
112" max
112" max
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Type 410 Stainless-Steel Titen Tension and Shear Load Values in Normal-Weight Concrete
Tension Load Shear Load Titen Drill Embed. Critical Critical f'c 4000 psi f'c 2000 psi Dia. Bit Depth Spacing Edge f'c 2000 psi (13.8 MPa) (27.6 MPa) (13.8 MPa) in. Dia. in. in. Dist. Concrete Concrete Concrete (mm) in. (mm) (mm) in. (mm) Ultimate Allow. Ultimate Allow. Ultimate Allow. lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 1 1 3 112 600 150 935 235 760 190 4 316 (25.4) (76.2) (38.1) (2.7) (0.7) (4.2) (1.0) (3.4) (0.8) (6.4) 1 3 112 1,040 260 1,760 440 810 200 4 316 112 (38.1) (76.2) (38.1) (4.6) (1.2) (7.8) (2.0) (3.6) (0.9) (6.4)
1. Maximum anchor embedment is 112" (38.1 mm). 2. Concrete must be minimum 1.5 x embedment.
Head Style
Model No.
Bit Quantity Dia. (in) Box Carton 100 1600 100 500 100 500 100 500 100 400 100 400 100 400 100 1600 100 500 100 500 100 500 100 400 100 400 100 400
Type 410 Stainless-Steel Titen Tension and Shear Load Values in Face Shell of Hollow and Grout-Filled CMU
Values for 6" or 8" Lightweight, Titen Drill Bit Embed. Critical Critical Dia. Dia. Depth Spacing Edge Medium-Weight or Normal-Weight CMU in. in. in. in. Dist. Tension Load Shear Load (mm) (mm) (mm) in. Ultimate Allow. Ultimate Allow. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 1 1 4 112 550 110 495 100 4 3 16 (25.4) (101.6) (38.1) (2.4) (0.5) (2.2) (0.4) (6.4)
1. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 2. Maximum anchor embedment is 112" (38.1 mm).
4 x 114 TTN25114HSS 4 x 134 TTN25134HSS 1 4 x 214 TTN25214HSS Hex 1 4 x 234 TTN25234HSS Head 1 4 x 314 TTN25314HSS 1 4 x 334 TTN25334HSS 1 4 x 4 TTN25400HSS 1 4 x 114 TTN25114PFSS 1 4 x 134 TTN25134PFSS 1 4 x 214 Phillips TTN25214PFSS 1 4 x 234 Flat TTN25234PFSS 1 4 x 314 Head TTN25314PFSS 1 4 x 334 TTN25334PFSS 1 4 x 4 TTN25400PFSS
One drill bit is included in each box
16
164
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Mechanical Anchors
4" dia.
1
12
48
For Drilling Overall Screw Depth Length Dia. (in.) (in.) (in.)
3
16 4
5 6 7 5 6 7
For Drilling Overall Screw Depth Length Dia. (in.) (in.) (in.)
3
32 x 5 32 x 7 3 16 x 5 3 16 x 7
16 4
5 7 5 7 165
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Mechanical Anchors
Installation Sequence
Drill Bit Quantity Dia. Box Carton (in.) 32 or 1 4 100 100 100 150 150 150 400 400 400 300 300 300
Heli-Tie Fastener Installation Tool - Model HELITOOL37A Required for correct installation of Heli-Tie wall ties. Speeds up installation and automatically countersinks the tie into the faade material. The one-piece design with no moving parts improves longevity and prevents the Heli-Tie fasteners from jamming. Installation tools sold separately.
HELITOOL37A
166
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Mortar Bed Joint Solid Brick 4 Brick Face Mortar Bed Joint Hollow Brick 5 Brick Face
32 4
3 (76)
1 7
32 4
1 7 7
32 32 4
1 7
32 4
1 7
Grout-Filled CMU 6
3
Web
32 4
234 (70)
1 7
(9.0)
32 4
1 7
32 4
1 7
Web
32 4
134 (44) 234 (70) 234 (70)
1 7
Normal-Weight Concrete 8
32 4
1 7
32 4
1 7
Center of Flange
32 4
1 (25)
Load at Max. Permitted Displ.3 lbs. (kN) 240 (1.1) 130 (0.6) 565 (2.5) 350 (1.6) 285 (1.3) 405 (1.8) 185 (0.8) 405 (1.8) 350 (1.6) 440 (2.0) 330 (1.5) 320 (1.4) 205 (0.9) 305 (1.4) 255 (1.1) 445 (2.0) 385 (1.7) 410 (1.8) 380 (1.7) 370 (1.6) 260 (1.2) 120 (0.5) 95 (0.4)
Standard Diviation lbs. (kN) 79 (0.4) 46 (0.2) 84 (0.4) 60 (0.3) 79 (0.4) 47 (0.2) 20 (0.1) 79 (0.4) 60 (0.3) 56 (0.2) 100 (0.4) 71 (0.3) 58 (0.3) 56 (0.2) 46 (0.2) 50 (0.2) 96 (0.4) 76 (0.3) 96 (0.4) 24 (0.1) 6 (0.0) 8 (0.0) 2 (0.0)
Caution: Loads are guide values based on laboratory testing. On-site testing shall be performed for verication of capacity since base material quality can vary widely.
1. Tabulated loads are guide values based on laboratory testing. On-site testing shall be performed for verication of capacity since base material quality can vary widely. 2. Ultimate load is average load at failure of the base material. Heli-Tie fastener average ultimate steel strength is 3,885 pounds and does not govern. 3. Load at maximum permitted displacement is average load at displacement of 0.157 inches (4 mm). The designer shall apply a suitable factor of safety to these numbers to derive allowable service loads. 4. Solid brick values for nominal 4-inch wide solid brick conforming to ASTM C62/C216, Grade SW. Type N mortar is prepared in accordance with IBC Section 2103.8. 5. Hollow brick values for nominal 4-inch wide hollow brick conforming to ASTM C216/C652, Grade SW, Type HBS, Class H40V. Mortar is prepared in accordance with IBC Section 2103.8. 6. Grout-lled CMU values for 8-inch wide lightweight, medium-weight and normal-weight concrete masonry units. The masonry units must be fully grouted. Values for 8-inch wide concrete masonry units (CMU) with a minimum specied compressive strength of masonry, f'm, at 28 days is 1500 psi. 7. Hollow CMU values for 8-inch wide lightweight, medium-weight and normal-weight concrete masonry units. 8. Normal-weight concrete values for concrete with minimum specied compressive strength of 2,500 psi. 9. 2x4 wood stud values for nominal 2x4 Spruce-Pine-Fir. 10. Metal stud values for 20-gauge C-shape metal stud. 11. For new construction. Anchor one end of tie into backup material. Embed other end into veneer mortar joint. Not for retrots due to difculty of locating center of 2x4 or metal stud flange.
Mechanical Anchors
(9.0)
167
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Crimp Multi-Purpose
Anchors
The Crimp anchor is an easy-to-install expansion anchor for use in concrete and grout-lled block. The pre-formed curvature along the shaft creates an expansion mechanism that secures the anchor in place and eliminates the need for a secondary tightening procedure. This speeds up anchor installation and reduces the overall cost. Four Crimp anchor head styles are available to handle different applications that include fastening wood or light-gauge steel, attaching concrete formwork, hanging overhead support for sprinkler pipes or suspended ceiling panels. WarnIng : Industry studies show that hardened fasteners can experience performance problems in wet or corrosive environments. Accordingly, with the exception of the duplex anchor, use these products in dry, interior and non-corrosive environments only. MATERIAL: Carbon steel FINISH: Zinc plated and mechanically galvanized Codes: Factory Mutual 3031136 for the 38" Rod Coupler. HEAD STYLES: Mushroom, rod coupler, tie-wire and duplex INSTALLATION: Drill a hole using the specified diameter carbide bit into the base material to a depth of at least 12" deeper than the required embedment. Blow the hole clean of dust and debris using compressed air. Overhead application need not be blown clean. Where a xture is used, drive the anchor through the fixture into the hole until the head sits flush against the xture. Be sure the anchor is driven to the required embedment depth. The Rod Coupler and Tie-Wire models should be driven in until the head is seated against the surface of the base material.
Mushroom Head
Rod Coupler
Mechanical Anchors
Size
Model No.
Ctn
16" x 1 14"
3
CD18114M CD18200M CD25100M CD25114M CD25112M CD25200M CD25212M CD25300M CD37200M CD37300M CD25300MG Mushroom Head Mechanically Galvanized Rod Coupler - Zinc Plated Tie Wire Zinc Plated Duplex Head - Zinc Plated Mushroom Head - Zinc Plated
16
8 8 8
1600 500 1600 1600 500 500 500 125 125 500
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
1 14
7 7
1 1
1600
4" x 2"
1
16
1 14 1 14 1 14 1 14 134 134 1 14
Duplex
4" x 2 2"
1 3 3
4" x 3"
Tie-Wire
16
16
16 4 4 4
1 14 112 118 1 14
Mushroom Head
1 4" Duplex
16
1. Mechanical galvanizing meets ASTM B695, Class 55, Type 1. Intended for some pressuretreated wood sill plate applications. Not for use in other corrosive or outdoor environments. See page 16 for details.
168
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Crimp Multi-Purpose
Anchors
*
Shear Load f'c 2000 psi Concrete Allowable Load (lbs.) 340 395 755 395 265 f'c 4000 psi Concrete Allowable Load (lbs.) 450 610 1305 610 325
f'c 4000 psi Concrete Allowable Load (lbs.) 250 275 780 275 215 250 600
MUSHROOM HEAD
3
16 4 8 4 4 4
16 4 8 4
114 1 4
1
3 3 4 3 3 3 4
1 3
1 3
1 3
16 4
1. The allowable loads listed are based on a safety factor of 4.0. 2. The minimum concrete thickness is 1 12 times the embedment depth. 3. Allowable loads may be linearly interpolated between concrete strengths listed. 4. For rod coupler, mechanical and plumbing design codes may prescribe lower allowable loads; verify with local codes.
*
Shear Load (Install in Concrete) f'c 3000 psi Concrete Allowable Load (lbs.) 345 375 1030 375 275 Shear Load (Install through Metal Deck) f'c 3000 psi Concrete Allowable Load (lbs.) 600 890 1085 890 210
Size (in.)
Tension Load (Install through Metal Deck) f'c 3000 psi Concrete Allowable Load (lbs.) 85 130 330 130 90 85 280
Mechanical Anchors
MUSHROOM HEAD
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
3
16 4 8 4 4 4
16 4 8 4 4
114 1 4
1
4 4 512 4 3 4 5
1 3
1 3
1 3
16 4
1. The allowable loads listed are based on a safety factor of 4.0. 2. The minimum concrete thickness is 1 12 times the embedment depth. 3. Anchors may be installed off-center in the flute, up to 1" from the center of flute. 4. Anchor may be installed in either upper or lower flute. 5. Deck profile shall be 3" deep, 20-gauge minimum. 6. For rod coupler, mechanical and plumbing design codes may prescribe lower allowable loads; verify with local codes.
Length Identification Head Marks on Mushroom And Duplex-Head Crimp Anchors (corresponds to length of anchor - inches)
Mark From Up To But Not Including 1 112 A 112 2 B 2 212 C 212 3 D 3 3 12
3" Deep, 20 Gauge Metal Deck Minimum
1" MAX. OFFSET
169
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
CSD (Countersunk)
MSD (Mushroom)
DSD (Duplex)
Installation Sequence
Head Style/ Finish Drill Bit Quantity Dia. Box Carton (in.) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 500 500 500 400 400 400 500 500 500 400 400 400 400 400 400
Mechanical Anchors
Model No. MSD25112 MSD25200 MSD25212 MSD25300 MSD25312 MSD25400 CSD25112 CSD25200 CSD25212 CSD25300 CSD25312 CSD25400 CSD25300MG CSD25400MG DSD25300
Countersunk Head Zinc Plated Countersunk Head Mechanically Galvanized 1 Duplex Head Zinc Plated
4 x 3 4 x 4 4 x 3
4 4
1. Mechanical galvanizing meets ASTM B695, Class 55, Type 1. Intended for some preservative-treated wood sill plate applications. Not for use in other corrosive or outdoor environments. See page 11 for details.
MSD & CSD Tension and Shear Load Values in Normal-Weight Concrete
Min. Tension Load (lbs.) Shear Load (lbs.) Drill Embed. Min. Size Bit Edge f'c 2000 psi f'c 2000 psi Depth Spacing (in.) Dia. Dist. Ultimate Allowable Ultimate Allowable (in.) (in.) (in.) (in.) Load Load Load Load
1
114
212
655
165
970
240
*
*See page 13 for an explanation of the load table icons
170
4 4
1 1
4 4
114 114
212 212
3 3
2500 4000
800 1060
200 265
2480 2740
620 685
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Installation Sequence Nylon Nailon Product Data and Tension Loads in Normal-Weight Concrete
Head Style R M R R M R M M R M Size (in.) Model No. N18100R N18100M N18112R N25100R N25100M N25112R N25112M N25200M N25200R N25300M Allowable Quantity Drill Bit Embed. Tension Dia. Depth Load (lbs.) (in.) (in.) f'c Box Carton 3000 psi 100 1600 7 20 8 3 100 1600 16 114 25 100 500 100 1600 7 20 8 100 1600 100 500 114 30 1 100 500 4 100 400 112 40 100 400 2 40 50 200
* Mechanical Anchors
16 x 1
16 x 112
1
4 x 1
4 x 112
1
4 x 2 4 x 3
Not for use in overhead applications These anchors are not recommended for eccentric tension (prying) loading. Capacity can be greatly reduced in such applications.
R = Round Head; M = Mushroom Head 1. Allowable loads listed are based on a safety factor of 4.0.
Zinc Nailon (Mushroom Head) Product Data and Tension and Shear Loads in Normal-Weight Concrete
Size (in.) 16 x 78 4 x 34 1 4 x 1 1 4 x 114 1 4 x 112 1 4 x 2 1 4 x 212 1 4 x 3
3 1
*
Quantity Box 100 100 100 100 100 100 100 100 Carton 1600 1600 500 500 500 400 400 400 Bulk
Carbon Steel Pin Model No. ZN18078 ZN25034 ZN25100 ZN25114 ZN25112 ZN25200 ZN25212 ZN25300
Stainless Steel Pin Model No. ZN25034SS ZN25100SS ZN25114SS ZN25112SS ZN25200SS ZN25212SS ZN25300SS
Allowable Load (lbs.) f'c 3000 psi Tension 165 165 225 255 285 285 310 310 Shear 120 120 225 225 225 260 260 260
16
4 8 7 8
3
1000
1. The allowable loads listed are based on a safety factor of 4.0. 2. Bulk Nailon anchors come packed in a single carton of 1,000. To order add a "B" onto the end of the model number. Example: ZN25100B. Not available with stainless-steel pins.
171
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
LSES
*
*See page 13 for an explanation of the load table icons
Installation Sequence
Mechanical Anchors
1. The allowable loads listed are based on a safety factor of 4.0. 2. The minimum concrete thickness is 112 times the embedment depth. 3. Screw is not included.
The ESA was the original internally threaded mechanical anchor design. The malleable lead shield allows for secure mounting. MATERIAL: Cone: Die Cast Zamac 3 alloy; Expander Shield: 3 - 5% antimonial lead INSTALLATION: Drill a hole in the base material using the appropriate diameter carbide drill bit as specified in the table. Drill the hole to the specified embedment depth plus 1 8" for flush mounting. Blow the hole clean using compressed air. Overhead installations need not be blown clean. Insert anchor into hole. Using a piloted setting punch, drive expander shield over cone. Position fixture; insert fastener and tighten. CODES: Meets Federal Specications A-A-1922A, Type 1, except ESA50.
Installation Sequence
ESA
*
1. The allowable loads listed are based on a safety factor of 4.0. 2. The minimum concrete thickness is 112 times the embedment depth. 3. Machine bolt is not included. 4. One piloted setting punch is included in each box.
3 1
4 - 20
8 - 16 2 - 13
8 2 3 4 7 8
8 8
114 112
172
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SMSA
DMSA
Installation Sequence
4 - 20 16 - 18 3 8 - 16 1 2 - 13
1
2 8 5 8 7 8
5
100 100 50 25
Mechanical Anchors
4 - 20 8 - 16
SMSA25 SMSA37
2 8
138 158
165 250
415 485
100 50
500 200
1. The allowable loads listed are based on a safety factor of 4.0. 2. The minimum concrete thickness is 112 times the embedment depth. 3. Machine bolt is not included.
1. Values for 8-inch wide concrete masonry units. The minimum specied compressive strength of masonry is 1,900 psi. 2. Embedment depth is measured from the outside face of the concrete masonry unit for installation through a face shell. 3. The tabulated allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. 4. All holes are drilled with a carbide-tipped drill bit in the rotation-only mode.
DMSA Product Data and Tension and Shear Loads in Normal-Weight Concrete
Tension Load Shear Load Bolt Model Drill Embed. Critical (dia. - threads No. Bit Depth Edge f'c 3000 psi f'c 4000 psi f'c 3000 psi per inch) Dia. in. Dist. (20.7 MPa) (27.6 MPa) (20.7 MPa) in. (mm) in. Allowable Allowable Allowable (mm) lbs. (kN) lbs. (kN) lbs. (kN) 1 1 2 3 265 305 370 1 4 - 20 DMSA25 12 (38) (76) (1.2) (1.4) (1.6) 134 312 290 335 690 5 16 - 18 DMSA31 58 (44) (89) (1.3) (1.5) (3.1) 214 412 765 920 1,300 3 8 - 16 DMSA37 34 (57) (114) (3.4) (4.1) (5.8) 3 1 2 4 5 2 765 920 1,770 1 2 - 13 DMSA50 78 (70) (140) (3.4) (4.1) (7.9) Quantity Box Carton 100 100 50 25 500 400 200 100
*
*See page 13 for an explanation of the load table icons
1. The allowable loads listed are based on a safety factor of 4.0. 2. 100% of the allowable load is permitted at critical edge distance. No reduction in edge distance is allowed. 3. The minimum concrete thickness is 112 times the embedment depth. 4. Machine bolt is not included.
173
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
HWA
Quantity Box 100 100 Carton 500 500
HWDA
Base Material Drill Bit Quantity Thickness Dia. Box Carton (in.) (in.) 16- 4 8- 12 5 8- 78 1 8- 12 5 8-1316 1 8- 12 5 8-1316
1 1 1
8SD 1 8LD
Installation Sequence
5 5
16 16 8
16
Mechanical Anchors
174
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model
PSATG06-R200 PSATG08-R200 PSATG10-R125 PSATG12-R70
Description
#6 Beige #8 Gray #10 Blue #12 Green
Quantity Box
200 200 125 70
Carton
1000 1000 625 350
3 3 3
Applications
8", 12", 58" drywall, plaster, brick, concrete, ceramic, stone 8", 12", 58" drywall, plaster, brick, concrete, ceramic, stone 8", 12", 58" drywall, plaster, brick, concrete, ceramic, stone
3
Mechanical Anchors
16 8
134 2
1. The allowable loads listed are based on a safety factor of 4.0. 2. The allowable loads listed are based on single anchor tests. 3. The performance of multiple anchors spaced closely together has not been investigated.
Tension 20 30 35
1. The allowable loads listed are based on a safety factor of 4.0. 2. The allowable loads listed are based on single anchor tests. 3. The performance of multiple anchors spaced closely together has not been investigated.
175
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
MATERIAL:
Sure Wall Standard: Die-cast zinc or reinforced nylon Sure Wall Gripper: Reinforced nylon Sure Wall Toggle: Reinforced nylon with a die-cast, zinc drilling point/toggle
8", 12" Drywall, Ceiling Tile, Plaster, Pegboard 8", 12", 58" Drywall, Plaster
Mechanical Anchors
Model
Style
Model
Style
Applications 8", 12", 58" Drywall 8", 12", 58" Drywall 8", 12", 58" Drywall 8", 12", 58" Drywall 8", 12", 58" Drywall 8", 12", 58" Drywall
8 x 2 8 x 3
SWNT12200-R50 Nylon Toggle SWNT12300-R50 Nylon Toggle SWNT18200-R50 Nylon Toggle SWNT18300-R50 Nylon Toggle SWNT25300-R25 Nylon Toggle SWNT25400-R25 Nylon Toggle
1 3 3
16 x 2 16 x 3 4 x 3 4 x 4
3 3 3
Sure Wall Nylon Toggle Tension and Shear Loads in 12" Drywall
Model SWNT12 SWNT18 SWNT25 Screw Size (in.) 1 8 3 16 1 4 Allowable Load1 (lbs.) Tension Shear 30 50 35 60 40 80
176
1. The allowable loads listed are based on a safety factor of 4.0. 2. The allowable loads listed are based on single anchor tests. 3. The performance of multiple anchors spaced closely together has not been investigated.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Size (in.) 1 8 x 2 1 8 x 3 3 16 x 2 3 16 x 3 3 16 x 4 3 16 x 5 1 4 x 3 1 4 x 4 1 4 x 5 5 16 x 3 5 16 x 4 5 16 x 5 5 16 x 6 3 8 x 3 3 8 x 4 3 8 x 5 3 8 x 6
Model No. SWTB12200R SWTB12300R/M 2 SWTB18200R SWTB18300R/M 2 SWTB18400R/M 2 SWTB18500R SWTB25300R/M 2 SWTB25400R/M 2 SWTB25500R SWTB31300R SWTB31400R SWTB31500R SWTB31600R SWTB37300R SWTB37400R SWTB37500R SWTB37600R
Quantity Box 100 100 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 Carton 500 500 250 250 200 200 200 200 200 100 100 100 100 100 100 100 100
Installation Sequence
8 2
Mechanical Anchors
178
11
16
2116
234
278
8 2 11 16 7 8
3 1
SWT Toggle
177
Time is money on the jobsite. When a contractor in the Midwest was falling behind schedule trying to tie down highway baskets, he turned to Simpson Strong-Tie. Once workers started using our PHBC powder-actuated clips, installation times dropped dramatically from about ve minutes per anchor to just seconds. Find out what many other professionals already know: Simpson Strong-Tie Gas- and Powder-Actuated Fastening Systems offer consistent, high-performance fastening into a variety of substrates.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
NEW
THe GCN-MEP Gas-ActuateD Concrete Nailer Kit incluDes: GCN-MEP nailer or GCN-MEPMAG 2 batteries Battery charger Allen wrenches Safety glasses and ear plugs Operators manual/tool schematic Rugged tool box
Replacement Parts
Model Description
179
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
GRH
GCC Pack Qty. 100 100 Pack Qty. 100 100 100 50 Pack Qty. 50 25 Pack Qty. 100 Pack Qty. 50 Pack Qty. 200 200 200 Pack Qty. 200 Pack Qty. 25 Pack Qty. 200 Compatible Gas-Actuated Nailer GCN-MEP, T3 GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 GCN-MEP, T3 GCN-MEP, T3 GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 GCN-MEP, T3 GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 Compatible Gas-Actuated Nailer GCN-MEP, T3 GTH GBR
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Description 1 2" Conduit Clip w/ .125" Dia. x 1" Length Pin 3 4" Conduit Clip w/ .125" Dia. x 1" Length Pin 1" Conduit Clip w/ .125" Dia. x 1" Length Pin 1" Conduit Clip (13 Gauge Steel) w/ .125" Dia. x 1" Length Pin Description 2" Conduit Clamp w/ .125" Dia. x 1" Length Pin 3 4" Conduit Clamp w/ .125" Dia. x 1" Length Pin Description Angle Clip w/ .125" Dia. x 1" Length Pin Description Tie Strap Holder w/ .125" Dia x 1" Length Pin Description 2" Dome Washer w/ .111"/ .125" Dia. x 12" Length Pin (Step Shank Pin) 1 2" Dome Washer w/ .125" Dia. x 34" Length Pin
1 1
GCL
GAC
GCT
Model No. GAC-R100 Model No. GCT-R50 Model No. GW50-R200 GW75-R200 GW100-R200 Model No. GTS-45075-R200 Model No. GBR2-R25 Model No. GTH-R200
1
GW
GTS
Description 4-20 thread, 12" length thread, 34" length shank (.125" dia shank) Description 2" Dia. Ring, w/ .125" Dia. x 1" Length Pin Description .125" Dia. x 1" Length Pin
Description .106" dia. x " pin .106" dia. x 58" pin .106" dia. x " pin .106" dia. x 1" pin .106" dia. x 1" pin .106" dia. x 1" pin Description 1.09"/1.11" dia. x " pin 1.09"/1.11" dia. x 58" pin 1.09"/1.11" dia. x " pin Description .110" dia. X 138" spiral knurled pin
Qty. Pins/Pack Compatible Gas-Actuated Nailer + 1 Fuel Cell 1,000 GCN150, GCN-MEP, TF1100, C3 1,000 1,000 1,000 1,000 1,000 Pack Qty. 1,000 1,000 1,000 Pack Qty. 1,000 GCN150, GCN-MEP, TF1100, C3 GCN150, GCN-MEP, TF1100, C3 GCN150, GCN-MEP, TF1100, C3 GCN150, GCN-MEP, TF1100, C3 GCN150, GCN-MEP, TF1100, C3 Compatible Gas-Actuated Nailer GCN150, GCN-MEP, TF1100, C3 GCN150, GCN-MEP, TF1100, C3 GCN150, GCN-MEP, TF1100, C3 Compatible Gas-Actuated Nailer GCN150, GCN-MEP, F100, C3
GDP
GDPS
GDPSK
GDPSK-137KT
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No.
Allowable Tension Load - lbs. (kN) Allowable Shear Load - lbs. (kN) Minimum Spacing f'c 2,000 psi f'c 3,000 psi f'c 4,000 psi f'c 2,000 psi f'c 3,000 psi f'c 4,000 psi In. (13.8 MPa) (20.7 MPa) (27.6 MPa) (13.8 MPa) (20.7 MPa) (27.6 MPa) (mm) Concrete Concrete Concrete Concrete Concrete Concrete 4 (101.6) 4 (101.6) 60 (0.27) 85 (0.38) 70 (0.31) 105 (0.47) 95 (0.42) 190 (0.85) 55 (0.27) 120 (0.53) 65 (0.29) 145 (0.65) 95 (0.42) 215 (0.96)
0.125 (3.2)
1. The fasteners must not be driven until the concrete has reached the designated minimum compressive strength. 2. Minimum concrete thickness must be three times the fastener embedment into the concrete. 3. The allowable tension and shear values are only for the fastener in the concrete. Members connected to the concrete must be investigated in accordance with accepted design criteria.
GCN-MEP Fasteners - Tension and Shear Loads in Sand-Lightweight Concrete over Metal Deck
Shank Diameter In. (mm) Minimum Penetration In. (mm)
5 8 (15.9) 3 4 (19.1)
*
*See page 13 for an explanation of the load table icons
Model No.
Installed in Concrete Allow. Tension Load lbs. (kN) 60 (0.27) 115 (0.51) Allow. Shear Load lbs. (kN) 110 (0.49) 130 (0.58)
Installed Thru. 3-inch "w" deck Allow. Tension Load lbs. (kN) 35 (0.16) 55 (0.24) Allow. Shear Load lbs. (kN) 215 (0.96) 235 (1.05)
0.125 (3.2)
1. The fasteners must not be driven through the steel deck and into the light3. The steel deck must have a minimum thickness of 20 gauge and a minimum weight concrete until the lightweight concrete has reached the designated yield strength of 38 ksi. minimum compressive strength. 4. The fasteners must be installed through the steel deck and into the concrete 2. The allowable tension and shear values are only for the fasteners driven at the lower ute. The fastener must be a minimum of 118" from the edge of the lower ute and 3 inches from the end of the deck. through the steel deck and into the lightweight concrete. Members connected by the fastener, driven through the steel deck and into the lightweight concrete, must be investigated in accordance with accepted design criteria.
Model No.
Installed in CMU Face Shell Allow. Tension Load lbs. (kN) 55 (0.24) Allow. Shear Load lbs. (kN) 65 (0.29)
GAS ACTUATED FASTENER STEEL THICKNESS ENTIRE POINTED PORTION OF THE FASTENER MUST PENETRATE THROUGH THE STEEL
1. The tabulated allowable load values are for the fasteners only. Members connected to the CMU receiving elements shall be designed in accordance with the applicable code and accepted design criteria. 2. The tabulated allowable load values are for fasteners installed in hollow CMUs conforming to ASTM C 90. The minimum allowable nominal size of the CMU must be 8 inches high by 8 inches wide by 16 inches long, with a minimum,1"-thick face shell thickness, medium-weight and normal-weight concrete masonry units. 3. The tabulated allowable load values are for fasteners installed in the center of a hollow CMU face shell.
Detail A
Model No.
Steel Thickness - (In.) Minimum 3 1 3 Minimum 16 4 8 Edge Spacing Distance Allow. Tension Allow. Shear Allow. Tension Allow. Shear Allow. Tension Allow. Shear In. In. Load lbs. Load lbs. Load lbs. Load lbs. Load lbs. Load lbs. (mm) (mm) (kN) (kN) (kN) (kN) (kN) (kN) ASTM A36 2 (12.7)
1
1 (25.4) 1 (25.4)
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values, see Detail A, except as noted in footnote 4. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be separately in accordance with accepted design criteria.investigated.
3. Steel must conform to ASTM A36 (Fy = 36 ksi, F4 = 58 ksi), ASTM A572 Grade 50 (Fy = 50 ksi, F4 = 65 ksi), or ASTM A992 (Fy = 50 ksi, F4 = 65 ksi). 4. Tabulated values are based on minimum penetration of the fastener point into steel of 0.25 inch (6.4mm).
181
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
FEATURES:
Fast: 40-pin magazine and 1,200-shot fuel cell for reduced loading time Easy to use: Automatic piston reset Easy open jam release door Portable: No hoses, cords, or external energy source required Convenient: Simple 2-step pin loading and open-blade guide-jam release Easy-load fuel compartment No possibility of ring with no pins when tool is down to last 2 pins in the pin magazine a "lock off" occurs Ladder hook
SPECIFICATIONS:
Tool dimensions: Length 17.3", Width 4.2", Height 15.3"
Weight: 8.3 lbs Magazine capacity: 42 Average number of fastens per fuel cell: 1,200 Average number of fastens per battery charge: 3,300 Fastener type: Length " to 1" Diameter .102" to .109"
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Replacement Part:
Model GCN-APP012 GCN-CHG007 GCN-PPA020 182 Description Adaptor Charger (U.S.) Battery (U.S.)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
GDP Pins
Qty. Pins / pack +1 Fuel Cell 1,000 1,000 1,000 1,000 1,000 1,000
Packs/ Carton 5 5 5 5 5 5
Compatible with these Tools Simpson Strong-Tie GCN-MEP, GCN-MEPMAG GCN150 Others: TF1100, C3
1 1 1
GDP
U.S. Patent 605016
Note: All installations are limited to dry, interior environments. GDP Tension Loads in Normal-Weight Concrete
Minimum Shank Penetration Diameter in. in. (mm)
5
Tension Loads Minimum Minimum Edge Spacing f'c 2000 psi (13.8 Mpa) f'c 3000 psi (20.7 Mpa) f'c 4000 psi (27.6 Mpa) f'c 5000 psi (34.5 Mpa) Distance in. Allow. Load Allow. Load Allow. Load Allow. Load in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) (mm) 3 (76.2) 4 (102) 25 (0.11) 30 (0.13) 30 (0.13) 30 (0.13) 45 (0.20) 30 (0.13) 45 (0.20) 30 (0.13)
0.106 (2.7)
(15.9) (19.1)
1. The fasteners must not be driven until the concrete has reached the designated minimum compressive strength. 2. Minimum concrete thickness must be three times the fastener embedment into the concrete. 3. The allowable tension values are only for the fasteners in the concrete. Members connected to the concrete must be investigated in accordance with accepted design criteria. C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Shear Loads Minimum Minimum Minimum Edge Shank Spacing f'c 2000 psi (13.8 Mpa) f'c 3000 psi (20.7 Mpa) f'c 4000 psi (27.6 Mpa) f'c 5000 psi (34.5 Mpa) Penetration Distance Diameter in. in. Allow. Load Allow. Load Allow. Load Allow. Load in. in. (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) (mm)
5
0.106 (2.7)
(15.9) (19.1)
3 (76.2)
4 (102)
25 (0.11) 45 (0.20)
25 (0.11) 55 (0.24)
25 (0.11) 75 (0.33)
25 (0.11) 75 (0.33)
1. The fasteners must not be driven until the concrete has reached the designated minimum compressive strength. 2. Minimum concrete thickness must be three times the fastener embedment into the concrete. 3. The allowable shear values are only for the fasteners in the concrete. Members connected to the concrete must be investigated in accordance with accepted design criteria.
183
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
*
Shear Loads f'c 3000 psi (20.7 Mpa) Allow. Load lbs. (kN) 35 (0.16)
Tension Loads f'c 3000 psi (20.7 Mpa) Allow. Load lbs. (kN) 75 (0.33)
105 140 (0.47) (0.62) (19.1) 1. The fasteners must not be driven until the lightweight concrete has reached the designated minimum compressive strength. 2. Minimum lightweight concrete thickness must be three times the fastener embedment into the lightweight concrete. 3. The allowable shear and tension values are only for the fasteners in the lightweight concrete. Members connected to the lightweight concrete must be investigated in accordance with accepted design criteria.
0.106 (2.7)
(15.9)
4 (102)
GDP Tension and Shear Loads in Sand-Lightweight Concrete over Metal deck
Tension Loads Shear Loads Tension Loads Shear Loads Minimum Minimum Minimum Thru 1.5" B Deck Thru 1.5" B Deck Thru 3" W Deck Thru 3" W Deck Edge Shank Spacing Penetration Distance Diameter f'c 3000 psi (20.7 Mpa) f'c 3000 psi (20.7 Mpa) f'c 3000 psi (20.7 Mpa) f'c 3000 psi (20.7 Mpa) in. in. in. in. Allow. Load Allow. Load Allow. Load Allow. Load (mm) (mm) (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN)
5
0.106 (2.7)
(15.9)
(0.58) (1.20) (0.27) (19.1) 1. The fasteners must not be driven through the steel deck and into the lightweight concrete until the lightweight concrete has reached the designated minimum compressive strength. 2. The allowable tension and shear values are only for the fasteners driven through the steel deck and into the lightweight concrete. Members connected by the fastener, driven through the steel deck and into the lightweight concrete, must be investigated in accordance with accepted design criteria. 3. The steel deck must have a minimum thickness of 20 gauge and a minimum yield strength of 38 ksi. 4. The fasteners must be installed through the steel deck and into the concrete at the lower flute. The fastener must be a minimum of 118" from the edge of the lower flute and 3 inches from the end of the deck.
1 (25.4)
4 (102)
65 (0.29) 130
60 (0.27) 60
(15.9)
3 (76.2)
1. The tabulated allowable load values are for the fasteners only. Members connected to the CMU receiving elements shall be designed in accordance with the applicable code and accepted design criteria. 2. The tabulated allowable load values are for fasteners installed in hollow CMUs conforming to ASTM C 90. The minimum allowable nominal size of the CMU must be 8 inches high by 8 inches wide by 16 inches long, with a minimum,114"-thick face shell thickness, lightweight concrete masonry units. 3. The tabulated allowable load values are for fasteners installed in the center of a hollow CMU face shell.
*
4" Thick
GAS ACTUATED FASTENER STEEL THICKNESS ENTIRE POINTED PORTION OF THE FASTENER MUST PENETRATE THROUGH THE STEEL
Shear Loads
3
16" Thick
4" Thick
16" Thick
Allow. Load Allow. Load Allow. Load Allow. Load lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 225 (1.00) 185 (0.82) 250 (1.11) 145 (0.64)
Detail A
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values. See Detail A. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria. 3. Steel must conform to ASTM A572 Grade 50 or A992 specifications, with Fy = 50 ksi, minimum.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Qty. Pins/ Pack Pack/ Carton + 1 fuel cell 1,000 1,000 1,000 5 5 5
2 4
Min. Allowable Tension Loads lbs. (kN) Allowable Shear Loads lbs. (kN) Min. Shank Min. PenMin. Edge Spacing etration Model Dia. Steel Distance Steel Thickness (in.) Steel Thickness (in.) in. in. in. No. Strength3 in. (mm) (mm) (mm) 3 1 3 1 3 1 3 1 16 4 8 2 16 4 8 2 (mm) 0.110 (2.8) GDPS 0.110 (2.8) THRU 0.5 (12.7) 0.5 (12.7) 1.0 (25.4) ASTM A36 95 170 1654 1454 180 265 2254 2254 (0.42) (0.76) (0.73)4 (0.64)4 (0.80) (1.18) (1.00)4 (1.00)4 205 305 2054 (0.91) (1.36) (0.91)4
THRU
ASTM A572, 110 170 1554 1.0 Grade 50 (0.49) (0.76) (0.69)4 (25.4) or ASTM A992
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values, unless otherwise indicated in footnote 4. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria. 3. Steel strength must comply with the minimum requirements of ASTM A 36 (Fy = 36 ksi, Fu = 58 ksi) or ASTM A 572, Grade 50 (Fy = 50 ksi, Fu = 65 ksi), or ASTM A992 (Fy = 50ksi, Fu = 65 ksi) 4. Tabulated values are based on minimum penetration depth of 0.35" (8.9 mm).
Fuel Cell
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
The GFC34 fuel cell is designed to operate with the GCN150 and GCN-MEP Gas-Actuated Concrete Nailers and also works with many major brand gas concrete-nailer tools. The fuel cell provides 1,200 shots and can operate at temperatures between 20120F (-649C). The fuel cells are offered in a 2-per-pack clamshell. Additionally, one fuel cell is included with each pack of 1,000 pins.
Compatible with these Tools SimpsonStrongTie GCN-MEP and GCN-150 Others: TrakFast TF1100, Trak-It C3
GFC34
185
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Spiral Knurl Gas Pins .110 Diameter Shank, .25 diameter Head, for the GCN150 or GCN-MEP with magazine
Model Length Qty pins/ pack + 1 fuel cell Packs/Carton Compatible with these Tools SimpsonStrongTie: GCN-150, GCN-MEP w/ magazine. Others: TF1100, C3
NEW
GDPSK-138KT
1 8"
3
1,000
GDPSK
Spiral Knurl Pin Tension and Shear Loads in Structural Steel Studs, 33 ksi Minimum Yield Strength
Model No. Shank Diameter in. (mm)
0.109 (2.77)
*
Shear lbs. (kN)
70 (0.31) 89 (0.40)
GDPSK-138
1. Entire pointed portion of the fastener must penetrate through the steel to obtain tabulated values. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria. 3. Fastener is to be installed in the center of the stud ange.
Model No.
GDPSK-138
1. Entire pointed portion of the fastener must penetrate through the steel to obtain tabulated values. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria. 3. Fastener is to be installed in the center of the stud ange.
186
Spiral Knurl Pin Tension and Shear Loads in Structural Steel Studs, 50 ksi Minimum Yield Strength
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
ALWAYS make sure that the operator and bystanders wear safety
glasses. Hearing and head protection are also recommended.
ALWAYS hold the tool perpendicular (90) to the fastening surface to NEVER attempt to fasten into soft, thin, brittle or very hard materials
such as drywall, light gauge steel, glass, tile or cast iron as these materials are inappropriate. Conduct a pre-punch test to determine base material adequacy. (fastening through soft materials into an appropriate base material may be allowed if the application is appropriate).
powder loads should be stored in a locked container out of the reach of children. even if no fastener is present. The fastener, pin or tool piston can cause serious injury or death in the event of an accidental discharge. or container with powder loads or fuel cells. These objects may strike the energy source, or puncture the fuel cell, thereby igniting and causing serious injury or death. on a powder- or a gas-actuated tool.
NEVER place any part of your body over the front muzzle of the tool
NEVER attempt to bypass or circumvent any of the safety features ALWAYS keep the tool pointed in a safe direction. ALWAYS keep your nger off the trigger. ALWAYS keep the tool unloaded until ready to use.
Safety equipment, such as safety glasses and ear plugs, are recommended when using powder-actuated tools.
PETH2 PETS2
PETBPA
PETBSM
NEW
PETG
Advantages: Modular lengths 2 ft., 6 ft., 8 ft. Easy jobsite storage Eliminates need for scaffolding Rugged and durable design
187
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Premium Tools
PTP-27L (Page 192) PTP-27LMAGR (Page 192) PTP-27S (Page 193) PTP-27SMAGR (Page 193)
FEATURES
Automatic Adjustable Power Low Recoil/Noise 2 2" Pin Capacity (4" Pin w/Washer)
1
Fully Automatic 10-Fastener Magazine Adjustable Power Low Recoil/Noise 278" Pin Capacity
Automatic Adjustable Power Low Recoil/Noise Drywall Track Tool 158" Pin Capacity
Fully Automatic Rotating Fastener Magazine 10-Fastener Magazine Adjustable Power Low Recoil/Noise 114" Pin Capacity
ELECTRICAL GENERAL FRAMER PLUMBING/ FIRE SPRINKLER ACOUSTICAL/ OVERHEAD REMODELING CARPENTRY FLOORING GLAZING HVAC RENTAL
Better
Best
Good Better
Good
Better Better
Best
188
DRYWALL
Good
Good
Best
Best
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Heavy-Duty Tool
PT-27HD (Page 194) PT-27 (Page 195)
General-Purpose Tools
PT-22 (Page 196) PT-22GS (Page 197) PT-22H (Page 198) PT-22P (Page 199)
FEATURES
Heavy Duty Single .27 Caliber Shot Long Reliable Design 38" Threaded Stud Sprinkler Tool with Stop Spall
SemiAutomatic Versatile Reliable Professional Grade Tool 212" Pin Capacity (4" Pin w/ Washer)
Single Shot Economical ProfessionalGrade Tool 3" Pin Capacity (4" Pin w/ Washer)
Single Shot Inline Trigger Tool Easier to use than hammerhit tool Medium Duty 3" Pin Capacity (4" Pin w/ Washer)
Single Shot Versatile, Professional Grade Tool 112" Pin Capacity 2" Pin w/ washer
DRYWALL ELECTRICAL GENERAL FRAMER PLUMBING/ FIRE SPRINKLER ACOUSTICAL/ OVERHEAD REMODELING CARPENTRY FLOORING GLAZING HVAC RENTAL Best Best
Good Good Better Good Good Good Good Good Good Good Good
Best Better
Good
Better Good
Good Better
Good
Good
Better
189
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
Page No.
All Yes
All Yes
All Yes
All Yes
Max 112" All Max 112" Max 2" Max 2" Max 2" Max 2" Max 2" Max 112" All Max 112" All All All All Max 112" 8mm Headed Pins
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
PDPH-XXX PDPW-XXX PDPWL-XXX PDPHWL-XXX PDPWLMG-XXX PINW-XXX PINWP-XXX PDPT-XXX PHBC-XXX PBXDP-XXX PCCXXX-DPXXX PECLDP-XXX PCLDP-XXX PSLV4-XXXXXX
203 204
PSLV3-XXXXXX
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
Page No.
General-Purpose Tools
PT-22 (Page 196) PT-22GS (Page 197) PT-22H (Page 198) PT-22P (Page 199)
LOADS P22AC1 thru 4 P25SL3 thru 5 P27SL2 thru 5 P27SL6 P27LVL3 thru 6 200 200 200 200 200 All .300 HEADED PINS PDP-XXX PDPA-XXX PDPH-XXX PDPW-XXX PDPWL-XXX PDPHWL-XXX PDPWLMG-XXX PINW-XXX PINWP-XXX
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
All
All
All
All
201 201 201 202 202 202 202 202 203 203 203 203 203 203 203 204
All
Max 212" All Max 212" All All All All All Max 212" All Max 212" All All All All
All All Max 212" All All All All All All All All All All All All All
All All All All All All All All All All All All All All All All
Max 212" Max 212" Max 212" All All All All All All All All All All All All All
Max 212" All Max 212" All All All All All Max 212" All Max 212" All All All All All
All
All
8MM HEADED PINS PHN-XXX PHNW-XXX PHNT-XXX PHSNA-XXX PTRHX-HN32 PKP-250 204 205 205 206 206 206
3
All
All All
All All
All
All
All All
PHV3-XXX PSLV3-XXXXXX
203 204
All All
191
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
NEW
PTP-27LMAGR
KEY FASTENING APPLICATIONS: Wood-framing applications Washered-pin installation (PTP-27S and PTP-27L only) Insulation fastening (PTP-27S and PTP-27L only) Forming work TOOL IS SOLD IN A RUGGED TOOL BOX COMPLETE WITH: Operators manual Spall suppressor Tools for disassembly Safety glasses / ear plugs Tool lubricant Cleaning brushes Operators exam and caution sign Tool box also sold separately Gloves OPTIONs: Extension pole tool for the PTP-27L available in 6' and 8' lengths. 6' Tool: PET-6PKT; 8' Tool: PET-8PKT Single shot conversion kit (PTP-27LXCON)
The patent pending, quick-disconnect baseplate makes it easy to convert the PTP-27LMAGR from a magazine to a single-shot tool
Extension Pole Tool (for the PTP-27L) - See page 187 for details
1. See page 207 for tool repair and maintenance kits. Complete tool schematics and parts list available at www.strongtie.com.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
PTP-27S
PTP-27SMAGR
The patent-pending quick-disconnect baseplate makes it easy to convert the PTP-27SMAGR from a magazine to a single shot tool
Extension Pole Tool (for the PTP-27S) - See page 187 for details
1. See page 207 for tool repair and maintenance kits. Complete tool schematics and parts list available at www.strongtie.com.
193
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
pt-27HD
FEATURES: Low recoil when setting 38" fasteners into steel or hard concrete Consistent and reliable performance Easy disassembly for cleaning and maintenance SPECIFICATIONS: Fastener Length: 12" thru 3" Fastener Types: 38" heavy-duty drive pins, .177 shank pins, 14"-20 threaded studs and 38"-16 threaded studs Firing Action: Single shot Load Caliber: .27 long single loads, green through purple (Levels 36) Length: 1414" Weight: 8 lbs., 13 oz. KEY FASTENING APPLICATIONS: 38" sprinkler fastenings Heavy-duty fastening into concrete strengths up to 8,000 psi, and structural steel TOOL IS SOLD IN A RUGGED TOOL BOX COMPLETE WITH: Operators manual Spall suppressor 8mm and 10mm fastener guides 8mm and 10mm pistons Small baseplate Stabilizer Ramrod Tools for disassembly Safety glasses / ear plugs Tool lubricant Cleaning brushes Operators exam and caution sign 2 extra stop rings
PT-27HD
The full line of SimpsonStrongTie Powder Loads and Fasteners begins on page 200.
194
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
PT-27
TOOL IS SOLD IN A RUGGED TOOL BOX COMPLETE WITH: Operators manual Spall suppressor Tools for disassembly Safety glasses / ear plugs Tool lubricant Cleaning brushes Operators exam and caution sign OPTION: Extension pole tool available in 6' and 8' lengths. 6' Tool: PET-6SMKT 8' Tool: PET-8SMKT
1. See page 207 for tool repair and maintenance kits. Complete tool schematics and parts list available at www.strongtie.com.
The full line of SimpsonStrongTie Powder Loads and Fasteners begins on page 200.
195
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
PT-22
TOOL IS SOLD IN A RUGGED TOOL BOX COMPLETE WITH: Operators manual Spall suppressor Tools for disassembly Safety glasses / ear plugs Cleaning brushes Operators exam and caution sign *These items not supplied with the PT-22-RB retail package.
1. Model PT-DC108 for tools with a serial number below 5000. 2. Model PT-DC107 for tools with a serial number below 5000. 3. Model PT-DC122 for tools with a serial number below 5000. 4. See page 207 for tool repair and maintenance kits. Complete tool schematics and parts list available at www.strongtie.com.
The PT-22 is sold individually in a tool box with accessories or in a retail package (see below).
PT-22-RB
196
The full line of SimpsonStrongTie Powder Loads and Fasteners begins on page 200.
PT-22-RB
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
PT-22GS
The full line of SimpsonStrongTie Powder Loads and Fasteners begins on page 200.
197
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
PT-22H
The full line of SimpsonStrongTie Powder Loads and Fasteners begins on page 200.
198
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
PT-22P
The full line of SimpsonStrongTie Powder Loads and Fasteners begins on page 200.
199
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
Compatible Tools SimpsonStrongTie Others 721, U-2000, DX-37E, DX72E, 4170 and model 70, System 3 and most lowvelocity, singleshot tools
P22AC
P22LRSC
Description .25 Cal. - Green (Level 3) .25 Cal. - Green BULK PACK .25 Cal. - Yellow (Level 4) .25 Cal. - Yellow BULK PACK .25 Cal. - Red (Level 5) .25 Cal. - Red BULK PACK
Model
Pack Qty.
P25SL3 100 10,000 P25SL3M 1,000 5,000 P25SL4 100 10,000 P25SL4M 1,000 5,000 P25SL5 100 10,000 P25SL5M 1,000 5,000
P25SL
DX-35, R35S
PT-27HD
P27LVL
P27SL2 P27SL2A-R100 P27SL3 .27 Cal. - Green (Level 3) P27SL3A-R100 .27 Cal. - Green BULK PACK P27SL3M P27SL4 .27 Cal. - Yellow (Level 4) P27SL4A-R100 .27 Cal. - Yellow BULK PACK P27SL4M P27SL5 .27 Cal. - Red (Level 5) P27SL5A-R100 .27 Cal. - Red BULK PACK P27SL5M .27 Cal. - Purple (Level 6) 200 P27SL6
P27SL
Note: An "A" in a part number denotes imported load. Non-A part number denotes domestic loads.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
Model PDPA-50 PDPA-50K PDPA-50KM PDPA-62K PDPA-62KM PDPA-75 PDPA-75M PDPA-100 PDPA-125 PDPA-150 PDPA-178 PDPA-200 PDPA-250 PDAP-278
Pack Qty 100 100 1000 100 1000 100 1000 100 100 100 100 100 100 100
Carton Qty 1000 1000 5000 1000 5000 1000 5000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
721**, D-60, U-2000, System 1, System 3 and most other lowvelocity tools.
PDPA
See pages 208 210 and 213 for load value information.
Model PDPH-50 PDPH-50K PDPH-62K PDPH-75 PDPH-100 PDPH-125 PDPH-150 PDPH-175 PDPH-200 PDPH-250 PDPH-300
Pack Qty. 100 100 100 100 100 100 100 100 100 100 100
Carton Qty. 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Compatible Tools SimpsonStrongTie PTP-27L* PTP-27S** PT-27* PT-22P PT-22 PT-22GS PT-22H Others
721**, D-60, U-2000, System 1, System 3 and most other lowvelocity tools.
PDPH
See page 209 for load value information.
316 Stainless Steel .300" Headed Fasteners with .145" Shank Diameter
Length (in.) 2 1 2 Knurled 5 8 Knurled 3 4 1 114 112 134 2 212 3 *Up to 212", ** Up to 112"
1
Model PDP-50SS PDP-50KSS PDP-62KSS PDP-75SS PDP-100SS PDP-125SS PDP-150SS PDP-175SS PDP-200SS PDP-250SS PDP-300SS
Pack Qty. 100 100 100 100 100 100 100 100 100 100 100
Carton Qty. 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Compatible Tools SimpsonStrongTie PTP-27L* PTP-27S** PT-27* PT-22P PT-22 PT-22GS PT-22H Others
721**, D-60, U-2000, System 1, System 3 and most other lowvelocity tools.
PDPSS
201
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
Mechanical Galvanizing meets ASTM B695, Class 65, Type 1. *Up to 212", **Up to 112"
PDPMG
See pages 209 for load value information.
.300" Headed Fasteners with .145" Shank Diameter and 34" Metal Washers
Length (in.)
3
Mechanical Galvanizing meets ASTM B695, Class 65, Type 1. *Up to 212", **Up to 112"
PDPHMG
See page 209 for load value information.
Model PDPW-75
Compatible Tools Pack Carton Qty. Qty. SimpsonStrongTie Others 100 1,000 1,000 PTP-27L PTP-27S* 1,000 PT-27 1,000 PT-22P PT-22 1,000 PT-22GS 1,000 PT-22H 1,000 721*, D-60, U-2000, System 1, System 3 and most other low velocity tools.
.300" Headed Fasteners with .145" Shank Diameter and 1" Metal Washers
Length (in.) 1 114 112 2 212 3 3 4
*Up to 2"
PDPW-100 100 PDPW-125 100 PDPW-150 100 PDPW-200 100 PDPW-250 100 PDPW-300 100
3
*Up to 2"
PDPW
.300" Headed Fasteners with .145" Shank Diameter and 1" Metal Washers Mechanically Galvanized with Protective Sleeve
Provides added corrosion protection in preservative-treated lumber. Visit www.strongtie.com for corrosion information. Plastic sleeve protects and preserves coating during installation; washer will not scrape off coating.
Compatible Tools Pack Carton Simpson Qty. Qty. Others Strong-Tie PDPWL-100 100 1,000 721*, PDPWL-125 100 1,000 D-60, PTP-27L PDPWL-150 100 1,000 PTP-27S* U-2000, System 1, PDPWL-200 100 1,000 PT-27 System 3 PDPWL-250 100 1,000 PT-22P PT-22 and most PDPWL-300 100 1,000 PT-22GS other low PDPWL-300M 1,000 PT-22H velocity tools. PDPWL-400 100 1,000 Model
PDPWL
.300" Headed Fasteners with 1" Metal Washers with .177" Shank Diameter
Length (in.) 1 114 112 2 212 3 4
*Up to 2"
Compatible Tools Pack Carton Qty. Qty. SimpsonStrongTie Others 100 1,000 PTP-27L PTP-27S* 100 1,000 PT-27
PT-22P
721*, D-60, U-2000, System 1, System 3 and most other low velocity tools.
PDPHWL
PDPWLMG
U.S. Patent 8,066,463
Mechanical Galvanizing meets ASTM B695, Class 65, Type 1. *PDPWLS has a square washer.
.300" Headed Fasteners with .145" Shank Diameter and 1716" Metal Washers
Length (in.) 1 114 112 134 2 214 212 3 Model PINW-100 PINW-125 PINW-150 PINW-175 PINW-200 PINW-225 PINW-250 PINW-300 Pack Carton Qty. Qty. 50 50 50 50 50 50 50 50 500 500 500 500 500 500 500 500 Compatible Tools Simpson Strong-Tie PTP-27L PT-27 PT-22 PT-22GS PT-22H
PT-22P
316 Stainless Steel .300" Headed Fasteners with .145" Shank Diameter and 1" Metal Washers*
Length (in.) 1 114 112 2 212 3 202 4 Model Compatible Tools Pack Carton Qty. Qty. SimpsonStrongTie Others
Others 721, D-60, U-2000, System 1, System 3 and most other low velocity tools.
PDPWL-100SS 100 1,000 PDPWL-125SS 100 1,000 PTP-27L PTP-27S** PDPWL-150SS 100 1,000 PT-27 PDPWL-200SS 100 1,000 PT-22P PT-22 PDPWL-250SS 100 1,000 PT-22GS PDPWL-300SS 100 1,000 PT-22H PDPWL-400SS 100 1,000
721**, D-60, U-2000, System 1, System 3 and most other low velocity tools.
PINW
PDPWL-SS
.300" Headed Fasteners 1" Metal Washers Plastic sleeve preventswith washer slipping during Mechanically Galvanized with Protective Sleeve installation.
Model
Compatible Tools Pack Carton Qty. Qty. Simpson Others Strong-Tie 100 1,000 721*, PTP-27L 100 1,000 PTP-27S D-60, U-2000, 100 1,000 PT-27 System 1, PT-27HD 100 1,000 System 3 PT-22P and most 100 1,000 PT-22 other low 50 500 PT-22GS velocity PT-22H tools. 50 500
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
.300" Headed Fasteners with .145" Shank Diameter and 138" Plastic White Washers
Length (in.) 1 114 112 134 2 212 3 Model PINWP-100W PINWP-125W PINWP-150W PINWP-175W PINWP-200W PINWP-250W PINWP-300W Compatible Tools Pack Carton Qty. Qty. Simpson Others Strong-Tie 50 500 721*, D-60, 50 500 PTP-27L* U-2000, System 1, 50 500 PT-27* PT-22P System 3 50 500 PT-22 and most 50 500 PT-22GS other low50 500 PT-22H velocity tools. 50 500
Model
Compatible Tools Simpson Strong-Tie PTP-27L PTP-27S PT-27 PT-22, PT-22P PT-22GS PT-22H Others 721, D-60, U-2000, System 1, System 3 and most other lowvelocity tools.
PDPT-75
100 1,000
PINWP
*Up to 212"
PDPT
Highway Basket Clips .300" Headed Fasteners with .145" Shank Diameter
Description Model Pack Carton Qty. Qty. 100 100 50 Compatible Tools SimpsonStrongTie Others DX-A41, Autofast
Clip with 112" Pin PHBC-150 Clip with 2" Pin PHBC-200 Clip with 212" Pin PHBC-250
PHBC
Pre-Assembled BX Cable Straps and Conduit Straps .300" Headed Fasteners with .145" Shank Diameter
Description BX Cable Strap with 1" Pin BX Cable Strap with 114" Pin Conduit Clip 12" EMT with 1" Pin Conduit Clip 12" EMT with 114" Pin Conduit Clip 34" EMT with 1" Pin Conduit Clip 34" EMT with 114" Pin Conduit Clip 1" EMT with 1" Pin Conduit Clip 1" EMT with 114" Pin
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Compatible Tools Pack Carton Qty. Qty. SimpsonStrongTie Others 100 1,000 100 1,000 PTP-27L D-60, 721, 100 1,000 PTP-27S System 1, 100 1,000 PT-27 PT-22P System 3, 50 500 PT-22 DX-350 50 1,000 PT-22GS and most other tools. 50 500 PT-22H 50 500
PCC
PBXDP
See pages 210 and 212 for load value information.
Pre-Assembled Ceiling Clips .300" Headed Fasteners with .145" Shank Diameter
Description Compact Ceiling Clip - No Pin Compact Ceiling Clip with 1" Pin Compact Ceiling Clip with 1" Pin - BULK PACK Compact Ceiling Clip with 114" Pin Ceiling Clip with 1" Pin Ceiling Clip with 114" Pin PCL PECLDP-100 PECLDP-100M PECLDP-125 PCLDP-100 PCLDP-125 Model Compatible Tools Pack Carton Qty. Qty. SimpsonStrongTie Others 100 100 100 100 100 1,000 1,000 PTP-27L PTP-27S 1,000 PT-27 1,000 PT-22P PT-22 1,000 PT-22GS 1,000 PT-22H 1,000 DX-350, System 1, 721 and most other tools.
For alternate overhead fastening, see the Tie Wire wedge anchor on page 133 or Tie Wire Crimp anchor on page 168.
PHV3
*Not intended for use in high-velocity tools.
203
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
Model PSLV4-5050K PSLV4-5075 PSLV4-50100 PSLV4-50125 PSLV4-7575 PSLV4-7550K PSLV4-75100 PSLV4-75125 PSLV4-100100 PSLV4-12550K PSLV4-125125
Pack Qty. 100 100 100 100 100 100 100 100 100 100 100
Carton Qty. 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
PSLV4
See pages 210, 211 and 214 for load value information.
*Shank diameter is .205". NOTE: T = Thread Length, S = Shank Length. **Factory Mutual Listing 3031724
PSLV3
Metric Fasteners
8MM Headed Fasteners with 3.68MM Shank Diameter
Length (in.)
1
See pages 209, 210 and 214 for load value information.
Model PHN-14K PHN-16K PHN-19K PHN-22 PHN-27 PHN-32 PHN-37 PHN-42 PHN-47 PHN-52 PHN-57 PHN-62 PHN-72
Pack Qty. 100 100 100 100 100 100 100 100 100 100 100 100 100
Carton Qty. 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
2 Knurled 5 8 Knurled 3 4 Knurled 7 8 1 114 112 158 178 2 214 212 278
DX-350, DX-36, DX-400E, DX-A40, DX-460, DX-A41, System 1, DX-351 and 8mm tools.
PHN
204
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
8MM Headed Fasteners with 3.68MM Shank Diameter and 1" Metal Washers
Length (in.) 1 114 112 158 178 2 214 212 278
*Up to 2"
Model PHNW-27 PHNW-32 PHNW-37 PHNW-42 PHNW-47 PHNW-52 PHNW-57 PHNW-62 PHNW-72
Pack Qty. 100 100 100 100 100 100 100 100 100
Carton Qty. 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Compatible Tools SimpsonStrongTie PTP-27L PTP-27S* PT-27 PT-22P PT-22 PT-22GS PT-22H Others DX-350, DX-36, DX-400E, DX-A40, DX-A41, DX-460, System1, DX-351 and 8mm tools.
PHNW
6MM Headed Fasteners with 3.68MM Shank Diameter and 12MM Washers
Length (in.)
7
Pack Qty. 100 100 100 100 100 100 100 100
Carton Qty. 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Compatible Tools DX-100L, DX-300, DX-400B, DX-450, DX-460, DX-451 and 12mm tools
PHK
Compatible Tools SimpsonStrongTie PTP-27L, PTP-27S PT-27, PT-22P, PT-22 PT-22GS, PT-22H Others DX-35, DX-351, and most 8mm tools
8 Knurled 3 4 Knurled
7
PHNT
205
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
Model
Pack Carton Qty. Qty. 100 100 100 100 100 100 100 100 100 100 100 100 100 100 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
2 Knurled PHSNA-14K 8 Knurled PHSNA-16K 3 PHSNA-19 4 3 4 Knurled PHSNA-19K 7 PHSNA-22 8 1 PHSNA-27 114 PHSNA-32 112 PHSNA-37 158 PHSNA-42 178 PHSNA-47 2 PHSNA-52 214 PHSNA-57 212 PHSNA-62 278 PHSNA-72
DX-A40 with magazine, DX-A41 with magazine, DX-351, DX-460 with magazine
PHSNA
Pack Qty. 50 50
Compatible Tools SimpsonStrongTie PTP-27L, PTP-27S PT-27, PT-22P PT-22 PT-22GS, PT-22H Others DX-351, DX-350, DX-36, DX-35, DX-A40
PTRH3
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Model
Compatible Tools SimpsonStrongTie PTP-27L, PT-27 PT-22, PT-22GS PT-22H Others DX-Series and 8mm tools
PKP-250
PKP
NOTE: Lengths in inches are for reference only and may not be exact.
206
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Powder-Actuated Tools
Pack Qty. 100 100 100 100 100 100 100 100
Carton Qty. 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
2 3 4
SimpsonStrongTie
Others
PHT-38
PHT-38
PHD
loads with this tool. This is a hammer drive tool only. Use of powder loads with this tool may result in injury or death.
PT-27
PT-27PK1
All
PT-MK1
All
PT-MTL2.0
Tool lubricant
207
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
Code Reports: Reference ICC-ES ESR-2138, Florida FL 11506.3 and City of L.A. RR25469 for code-listed fasteners and applications
16
16
260 (1.16)
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values, unless otherwise indicated in footnote 4, 5, 6 or 7. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria. 3. Steel strength must comply with the minimum requirements of ASTM A 36 (Fy = 36 ksi, Fu = 58 ksi) or ASTM A 572, Grade 50 (Fy = 50 ksi, Fu = 65 ksi), or ASTM A992 (Fy = 50 ksi, Fu = 65 ksi)
4. Based upon minimum penetration depth of 0.46" (11.7 mm). 5. Based upon minimum penetration depth of 0.58" (14.7 mm). 6. Based upon minimum penetration depth of 0.36" (9.1 mm). 7. The fastener must be driven to where the point of the fastener penetrates through the steel.
PDPA
Model No.
PDPA
1. The fastener shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete.
2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria.
PDPA Tension and Shear Loads in Lightweight Concrete over Metal Deck
Model No. Shank Diameter in. (mm) Minimum Penetration in. (mm) 4 (19) 1 (25) 114 (32)
3
Allowable Tension Load - lbs. (kN) Installed In Concrete 85 (0.38) 150 (0.67) 320 (1.42) Installed Thru. Metal Deck 105 (0.47) 145 (0.64) 170 (0.76)
Allowable Shear Load lbs. (kN) Installed In Concrete 105 (0.47) 225 (1.00) 420 (1.87) Installed Thru. Metal Deck 280 (1.25) 280 (1.25) 320 (1.42)
PDPA
0.157 (4.0)
1. The fastener shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be investigated separately in accordance with accepted design criteria.
3. Metal deck must be minimum 20 gauge and has a minimum yield strength of 38,000 psi. 4. Shear values are for loads applied toward edge of ute. 5. The fastener shall be installed 112" from the edge of ute.
208
0.157 (4.0)
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
The table applies to the following SimpsonStrongTie fasteners where minimum penetration exists: PDP* PDPW* PDPW-125 PDPW-150 PDPW-175 PDPW-200 PDPW-225 PDPW-250 PDPW-300 PDPWL* PDPWL-125 PDPWL-150 PDPWL-175 PDPWL-200 PDPWL-225 PDPWL-250 PDPWL-300 PDPWL-400 PDP-125 PDP-150 PDP-175 PDP-200 PDP-225 PDP-250 PDP-300
PDPW
PHN PHN-27 PHN-32 PHN-37 PHN-42 PHN-47 PHN-52 PHN-57 PHN-62 PHN-72
PHNW PHNW-27 PHNW-32 PHNW-37 PHNW-42 PHNW-47 PHNW-52 PHNW-57 PHNW-62 PHNW-72
PHSNA PHSNA-27 PHSNA-32 PHSNA-37 PHSNA-42 PHSNA-47 PHSNA-52 PHSNA-57 PHSNA-62 PHSNA-72
For more information on these fasteners go to pages 204, 205 and 206. PHN PHNW PHSNA
Spacing of PDP and PHN Fasteners for Attachment of Wood Sill Plates to Normal-Weight Concrete
Model No. PDPW-300 PDPWL-300 PDPWL-300MG PDPWLS-300MG PHN-72 or PHNW-72 Overall Head Shank Length Diameter Diameter inches inches inches (mm) (mm) (mm) 3 (76) 278 (73)
5
*
Maximum Spacing inches (mm)
Interior Exterior Interior Shear Walls 3 Nonshear Walls 2 Shear Walls 3 12 (305) 18 (457) 24 (610) 36 (914) 12 (305) 18 (457)
(7.9)
5
16 16
(7.9)
1. Spacings are based upon the attachment of 2-inch (nominal thickness) wood sill plates, with specic gravity of 0.50 or greater, to concrete oor slabs or footings. For species of wood with specic gravity of 0.42 to 0.49, multiply required spacing of fasteners for shear walls by 0.81. For species of wood with specic gravity of 0.31 to 0.41, multiply the required spacing of fasteners for shear walls by 0.65. 2. All walls shall have fasteners placed at 6 inches from ends of sill plates, with maximum spacing as shown in the table. 3. Fasteners indicated shall have two pins placed 6 inches and 10 inches, respectively, from each end of sill plates, with maximum spacing as shown in the table. 4. All fasteners must be installed with a minimum 34-inch-diameter, No. 16 gauge (0.0598 inch) steel washer. 5. Fasteners shall not be driven until the concrete has reached a compressive strength of 2,000 psi. Minimum edge distance is 134 inches. 6. The fasteners shall not be used for the attachment of shear walls having a unit shear in excess of 100 pounds per foot. Spacings shown are independent of the number of building stories.
209
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
PDPH
Allowable Tension Load - lbs. (kN) Allowable Shear Load - lbs. (kN) Shank Minimum Minimum Minimum Diameter Penetration Edge Distance Spacing f'c 2000 psi f'c 4000 psi f'c 6000 psi f'c 2000 psi f'c 4000 psi f'c 6000 psi inches inches inches inches (13.8 MPa) (27.6 MPa) (41.4 MPa) (13.8 MPa) (27.6 MPa) (41.4 MPa) (mm) (mm) (mm) (mm) Concrete Concrete Concrete Concrete Concrete Concrete 3 312 518 30 30 110 50 110 190 4 (89) (130) (0.13) (0.13) (0.29) (0.22) (0.49) (0.84) (19) 0.177 (4.5) 114 312 518 130 260 190 265 220 105 (32) (89) (130) (0.58) (1.15) (0.84) (1.18) (0.98) (0.47)
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria.
PDP and PHN Fasteners Attaching Light Gauge Steel Channels - Shear Loads in Normal Weight Concrete
Model No. PDP
Allowable Shear Load Shank Minimum Light Gauge lbs. (kN) Diameter Penetration Steel Channel inches inches Thickness f'c 2000 psi (13.8 MPa) 1. The fasteners shall not be driven until (mm) (mm) gauge Concrete the concrete has 7 0.145 160 8 reached the 20 (3.7) (0.71) (22) designated 7 0.145 160 8 compressive 20 (3.7) (0.71) (22) strength. Minimum 7 concrete thickness 0.145 135 8 18 is three times the (3.7) (0.60) (22) faster embedment 7 0.145 135 8 18 into the concrete. (3.7) (0.60) (22)
PDP
PHN
*
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
PSLV3
*
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria.
*
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the faster embedment into the concrete.
210
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
Shank Minimum Allowable Tension Load, lbs. (kN) Allowable Tension Load, lbs. (kN) (Installed in Concrete) (Installed through Metal Deck) Model Diameter Penetration No. inches inches f'c 3000 psi (20.7 MPa) f'c 3000 psi (20.7 MPa) (mm) (mm) Concrete Concrete 7 0.145 90 40 8 PDPT (3.7) (0.40) (0.18) (22)
PDPT Series Fasteners - Shear Loads in Lightweight Concrete over Metal Deck
Shank Minimum Model Diameter Penetration No. inches inches (mm) (mm) PDPT 0.145 (3.7)
7
*
Allowable Shear Load, lbs. (kN) (Installed through Metal Deck) f'c 3000 psi (20.7 MPa) Concrete 280 (1.24)
Allowable Shear Load, lbs. (kN) (Installed in Concrete) f'c 3000 psi (20.7 MPa) Concrete 250 (1.11)
(22)
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension and shear values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria. 3. Metal deck must be minimum 20 gauge. 4. Shear values are for loads applied toward edge of ute. 5. The fasteners shall be installed 112 inch from the edge of ute.
Tension Loads for 14" - 20 Threaded Studs in Lightweight Concrete Over a Metal Deck
Model No. PSLV4
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
*
*See page 13 for an explanation of the load table icons
Allowable Tension Load, lbs. (kN) (Installed through Metal Deck) f'c 3000 psi (20.7 MPa) Concrete 80 (0.36)
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria. 3. Metal deck must be minimum 20 gauge. 4. The fasteners shall be installed 112 inch from the edge of ute.
Tension Loads for 38 - 16 Threaded Studs in Lightweight Concrete over Metal Deck
Model No. PSLV3 Shank Diameter inches (mm) 0.205 (5.21) Minimum Penetration inches (mm) 114 (32) Allowable Tension Load, lbs. (kN) (Installed through Metal Deck) f'c 3000 psi (20.7 MPa) Concrete 225 (1.00)
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria. 3. Metal deck must be minimum 20 gauge. 4. The fasteners shall be installed 112 inch from the edge of ute.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
Shank Minimum Allowable Tension Load, lbs. (kN) Allowable Oblique Load, lbs. (kN) (Installed through Metal Deck) Diameter Penetration (Installed through Metal Deck) inches inches f'c 3000 psi (20.7 MPa) f'c 3000 psi (20.7 MPa) (mm) (mm) Concrete Concrete 7 55 85 0.145 8 (0.24) (0.38) (3.7) (22) 0.145 1 55 85 (3.7) (25) (0.24) (0.38) 0.145 1 55 85 (3.7) (25) (0.24) (0.38) 0.145 1 55 85 (3.7) (25) (0.24) (0.38) 0.145 1 55 85 (3.7) (25) (0.24) (0.38)
PCLDP
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension and shear values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria. 3. Metal deck must be minimum 20 gauge. 4. Oblique values are for loads applied toward edge of ute. 5. The fasteners shall be installed 112 inch from the edge of ute.
PTRH Series Threaded Rod Hangers - Tension Loads in Sand-Lightweight Concrete over Metal Deck
*
*See page 13 for
Shank Minimum Allowable Tension Load, lbs. (kN) an explanation Model Diameter Penetration (Installed through Metal Deck) of the load table icons No. inches inches f'c 3000 psi (20.7 MPa) (mm) (mm) Concrete 0.145 1 140 PTRH3-HN32 (3.7) (25) (0.62) 0.145 1 140 PTRH4-HN32 (3.7) (25) (0.62)
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria. 3. Metal deck must be minimum 20 gauge. 4. The fasteners shall be installed 112 inch from the edge of ute.
PHNT Series Fasteners - Tension Loads in Sand-Lightweight Concrete Over Metal Deck
Shank Minimum Allowable Tension Load, lbs. (kN) Allowable Tension Load, lbs. (kN) (Installed in Concrete) (Installed through Metal Deck) Model Diameter Penetration No. inches inches f'c 3000 psi (20.7 MPa) f'c 3000 psi (20.7 MPa) (mm) (mm) Concrete Concrete 7 185 165 0.145 8 PHNT (0.82) (0.73) (3.7) (22)
See notes 15 below.
PHNT Series Fasteners - Shear Loads in Sand-Lightweight Concrete Over Metal Deck
Shank Minimum Model Diameter Penetration No. inches inches (mm) (mm) PHNT 0.145 (3.7)
7
*
Allowable Shear Load, lbs. (kN) (Installed through Metal Deck) f'c 3000 psi (20.7 MPa) Concrete 400 (1.78)
Allowable Shear Load, lbs. (kN) (Installed in Concrete) f'c 3000 psi (20.7 MPa) Concrete 275 (1.22)
(22)
212
1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete. 2. The allowable tension and shear values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria. 3. Metal deck must be minimum 20 gauge. 4. Shear values are for loads applied toward edge of ute. 5. The fasteners shall be installed 112 inch from the edge of ute.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
8-inch Hollow CMU Loads Shank Minimum Minimum Minimum Minimum Based on CMU Strength Model Diameter Penetration Edge Distance End Distance Spacing Tension Load Shear Load No. inches inches inches inches inches Allowable Allowable (mm) (mm) (mm) (mm) (mm) lbs. (kN) lbs. (kN) 4 458 4 110 200 0.145 134 PDP (44) (100) (116) (100) (0.50) (0.90) (3.7)
1. Values for 8-inch wide CMU Grade N, Type II, lightweight, medium-weight and normal weight concrete masonry units conforming to UBC Standard 21-4 or ASTM C90. 2. The embedment depth is measured from the outside face of the concrete masonry unit and is based on the anchor being embedded an additional 12 inch through 114" thick face shell. 3. Allowable loads may not be increased for short-term loading due to wind or seismic forces. CMU wall design must satisfy applicable design standards and be capable of withstanding applied loads.
PDP
(12.7) (12.7)
2 2
1 (25) 1 (25)
(4.8)
1
16 4
(6.4)
395 (1.76)
*
*See page 13 for an explanation of the load table icons
PDP
PDPH
PDPH
0.177 (4.5)
(13)
1 (25)
(5)
1
16 4
(6)
C-SAS-2012 2012 Simpson Strong-Tie Company Inc. 1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values. See Detail A. 2. The allowable tension and shear values are for the fastener to steel only. Connected members must be investigated separately in accordance with accepted design criteria. 3. Steel must conform to ASTM A36 specications, with Fy = 36,000 psi, minimum.
GAS ACTUATED FASTENER STEEL THICKNESS ENTIRE POINTED PORTION OF THE FASTENER MUST PENETRATE THROUGH THE STEEL
The table applies to the following SimpsonStrongTie fasteners where minimum penetration exists:
PDP PDP-50K PDP-62K PDP-100 PDP-125 PDP-150 PDP-175 PDP-200 PDP-225 PDP-250 PDP-300
PDPWL
PDPW
Detail A
PDPT
0.145 (3.7)
(13)
(3) 1 (25)
3
(5)
1
16 4
(6)
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated value. See Detail A. 2. The allowable tension and shear values are for the fastener to steel only. Connected member must be investigated separately in accordance with accepted design criteria. 3. Steel must conform to ASTM A36 specications, with Fy = 36,000 psi, minimum.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Fasteners
Shank Minimum Minimum Steel Allowable Allowable Model Diameter Edge Distance Spacing Thickness 3 Tension Load 2 Shear Load 2 No. inches inches inches inches lbs. lbs. (mm) (mm) (mm) (mm) (kN) (kN) PHN PHN 4 Knurled 0.145 (3.7) 0.145 (3.7)
1 1
(12.7) (12.7)
2 2
1 (25) 1 (25)
(4.8)
1
16 4
(6.4)
395 (1.76)
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values. See Detail A. 2. The allowable tension and shear values are for the fastener into steel only. Wood members connected must be investigated separately in accordance with accepted design criteria. 3. Steel must conform to ASTM A 36 specications, with Fy = 36,000 psi, minimum. 4. PHN-16K or longer.
The table applies to the following SimpsonStrongTie fasteners where minimum penetration exists:
PHN
PHNW
PHN PHN-16K PHN-19K PHN-27 PHN-32 PHN-37 PHN-42 PHN-47 PHN-52 PHN-57 PHN-62 PHN-72
PHNW PHNW-27 PHNW-32 PHNW-37 PHNW-42 PHNW-47 PHNW-52 PHNW-57 PHNW-62 PHNW-72
PHSNA PHSNA-16K PHSNA-19K PHSNA-27 PHSNA-32 PHSNA-37 PHSNA-42 PHSNA-47 PHSNA-52 PHSNA-57 PHSNA-62 PHSNA-72
PHSNA For more information on these fasteners go to pages 204, 205 and 206.
Detail A
ENTIRE POINTED PORTION OF THE FASTENER MUST PENETRATE THROUGH THE STEEL
PHNT
0.145 (3.7)
(13)
1 (25)
(5)
1
16 4
(6)
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated value. See Detail A. 2. The allowable tension and shear values are for the fastener to steel only. 3. Steel must conform to ASTM A36 specications, with Fy = 36,000 psi, minimum.
PSLV3
0.205 (5.2)
1 (25)
158 (41)
(5)
1 3
16 4
(13)
1 (25)
(5)
1
16 4
(6)
PSLV3
PSLV4
214
1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated value. See Detail A. 2. The allowable tension and shear values are for the fastener to steel only. Connected member must be investigated separately in accordance with accepted design criteria. 3. Steel must conform to ASTM A36 specications, with Fy = 36,000 psi, minimum.
(3)
Simpson Strong-Tie offers a complete line of premiumquality drill bits, core bits and chisels to handle any drilling and demolition need. Our carbide products are manufactured to demanding tolerances and are designed to maximize production on the jobsite.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SimpsonStrongTie Drill Bits come in various shank styles to t virtually any drill or rotohammer.
Quad Head4x
SDS-MAX
Fits all current and older SDS MAX rotohammers from Black & Decker, Bosch, DeWalt, Hitachi, Hilti, Kango, Makita, Metabo, Milwaukee
Fits all current and older Spline rotohammers from AEG, Black & Decker, Bosch, DeWalt, Hitachi, Kango, Makita, Metabo, Milwaukee, Ramset, Red Head, Ryobi
Spline
216
The following are registered trademarks: AEG AEG Power Tool Corp. Bosch Robert Bosch Power Tool Corp. SDS Plus and SDS Max are registered
trademarks of Robert Bosch Power Tool Corp. B&D Black and Decker US, Inc. Hilti Hilti of America, Inc. Hitachi Hitachi Power Tools USA, Ltd.
Kango Kango Wolf Power Tools, Inc. Makita Makita USA, Inc. Metabo Metabo Corp. Milwaukee Milwaukee Electric Tool Corp.
Porter Cable Porter Cable Corporation Ramset Illinois Tool Works Red Head Illinois Tool Works Ryobi Ryobi America Corporation
QuaD HeaD Feature: (Available in SDS-PLUS, SDS-MAX and Spline Shank) All the features of single cutter bits plus Quad Head dual cutter design to improve durability and drilling speed. The high volume, double helix of Quad Head bit is produced with the patented, highperformance, reinforced core ute to maximize energy transfer.
SDS MAX
SDS PLUS
Spline
Straight
A Taper
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Dia. (in.)
5
Model No.
MDPL01506-R25 MDPL01804-R25 MDPL01806-R25 MDPL01808-R25 MDPL01810-R25 MDPL01812-R25 MDPL01814-R25 MDPL02106-R25 MDPL02108-R25 MDPL02111-R25 MDPL02504-R25 MDPL02506-R25 MDPL02508-R25 MDPL02511-R25 MDPL03106-R25 MDPL03706-R25 MDPL03712-R25 MDPL05006-R25 MDPL05012-R25 MDPL06208-R20
32
32
16
16
32
6 8 2 4 6 8 4 4 10 4 10 6
32
16 8
16
10 16 22 4 10 4 8
Model No.
MDPL07508Q MDPL07512Q MDPL07518Q MDPL08708Q MDPL08712Q MDPL08718Q MDPL10010Q MDPL10018Q MDPL11210Q MDPL11218Q
8 12 18 8 12 18 10 18 10 18
16
10 16 8 16 8 16
Quad Head4x
10 16 22 4
1 1 8
1
16
10 16 6 10 16 22 6 6 8
11
16
Model No.
MDPL01505H MDPL01506H MDPL01507H MDPL01805H MDPL01806H MDPL01807H
Drill Bits
5 6 7 5 6
3 3 3
16 16 16
10 16 22
32
16
318
13
16
6 6 6 10 16 8 16
27
32 8
Special hex adaptor (included with the Titen Screw installation kit) allows the Titen installation tool to slide over the bit and lock in, ready to drive Titen concrete and masonry screws. Rotohammer must be in rotation-only mode before driving screws.
32 16
For Drilling Overall Screw Depth Length Model No. Dia. (in.) (in.) (in.) 3 238 5 16 MDPL01505H-R25 418 238 418 7 5 7
3
16
217
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No.
MDMC03713 MDMX05013 MDMX05021 MDMX05613 MDMX05621 MDMX06213Q MDMX06221Q MDMX06236Q MDMX06821Q MDMX07513Q MDMX07521Q MDMX07536Q MDMX08121Q MDMX08713Q MDMX08721Q MDMX10013Q MDMX10021Q MDMX10036Q MDMX10623Q MDMX11217Q MDMX11221Q MDMX11823Q MDMX12515Q MDMX12523Q MDMX12536Q MDMX13717Q MDMX13723Q MDMX15023Q MDMX17523Q MDMX20023Q
Model No.
MDSP03710 MDSP03713 MDSP03716 MDSP04313 MDSP05010 MDSP05013 MDSP05016 MDSP05022 MDSP05029 MDSP05036 MDSP05613 MDSP05616 MDSP05623 MDSP06210 MDSP06213 MDSP06216 MDSP06222 MDSP06229 MDSP06236 MDSP06813 MDSP06816 MDSP07510 MDSP07513 MDSP07516 MDSP07522 MDSP07529 MDSP07536 MDSP08716 MDSP08736 MDSP10016 MDSP10022 MDSP10036 MDSP11216 MDSP11222 MDSP12516 MDSP12522 MDSP13716 MDSP13722 MDSP15016 MDSP15022 MDSP17522 MDSP20022 MDSP08722
10 13 16 13 10 13 16 22 29 36 13 16 23 10 13 16 22 29 36 13 16 10 13 16 22 29 36 16 22 36 16 22 36 16 22 16 22 16 22 16 22 22 22
8 11 8 5 8 11 17 22 31 8
16
16
8 16
11
13
16
11 18 5 8 11 17 24 31 8 11 5 8 11 17 24 31 11
16
11
16
138 1 1 2
Quad Head
4x
31 11 1 17 31 118 1 138 1 1 2 11 17 11 17 11 17 11 17 17 17
MDPL01804S MDPL01806S MDPL01808S MDPL01812S MDPL02506S MDPL02508S MDPL02512S MDPL03106S MDPL03112S MDPL03706S MDPL03712S MDPL05006S MDPL05012S MDPL05606S MDPL05612S
16 16 16 16 4 4 4
2 4 6 10 4 6 10 4 10 4 10 4 10 4 10
1 1 1 5 5
16 16 8 8 2 2
3 3 1 1 9 9
16 16
6 12
218
17
Drill Bits
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No.
MDSP06210Q MDSP06216Q MDSP06222Q MDSP06229Q MDSP06236Q MDSP06816Q MDSP07510Q MDSP07516Q MDSP07522Q MDSP07529Q MDSP07536Q MDSP08716Q MDSP08722Q MDSP10016Q MDSP10022Q MDSP10036Q MDSP11216Q MDSP11222Q MDSP12516Q MDSP12522Q MDSP12536Q MDSP13716Q MDSP13722Q MDSP15022Q MDSP17523Q MDSP20023Q
10 16 22 29 36 16 10 16 22 29 36 16 22 16 22 36 16 22 16 22 36 16 22 22 23 23
17 24 31
16
11
16
11 5 11
16 8
17 24 31 11 17 11 17 31 11 17 11 17 31 11 17 17 18 18
16
10 22 4 10 4 10 4 10
118
138 1 1 2
1. Bits have recessed shank to t Titen screws and other masonry screw installation tools. They also work in three-jaw style chucks.
Quad Head4x
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
A Taper Bit
Model No.
32
2 4
16
Drill Bits
16
16 8
219
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No.
MCR05012 MCR06212 MCR07512 MCR08712 MCR10012 ** After drilling through the reinforcement or plate, remove debris from the hole and resume drilling with carbide tipped drill bit.
Rebar Cutter
Plate Cutters**
Similar to Rebar Cutters, these bits are designed for cutting through steel base plates when it is necessary to enlarge the xture hole. These bits can also be used as rebar cutters. Plate cutters are separate from shanks. Shanks work with all sizes of plate cutters.
Dia. (in.)
5
Model No.
MCP05012 MCP06212 MCP07512 MCP08712 MCP10012 ** After drilling through the reinforcement or plate, remove debris from the hole and resume drilling with carbide tipped drill bit.
Plate Cutter
Model No.
MC MCSDP MCSDM
Description For use in drills with jawed chucks. Use in rotation mode only. For use in SDS-Plus style drills. Use in rotation only. For use in SDS-Max style drills. Shank design allows rotation only. For use in Spline style drills. Shank design allows rotation only.
SDS-Plus Shank
SDS-Max
Spline
MCS
Spline Shank
Model No.
ADMX2PL ADSP2PL ADST2PL
220
Drill Bits
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No.
CHPLF07510 CHPLSC15010 CHMXSCP20012 CHSPSCP20012
Scraper SimpsonStrongTie Demolition Chisels and Bits come in various shank styles to t virtually any demolition tool.
Model No.
CHMXF10012 CHMXF10018 CHSPF10012 CHSPF10018 CHHF10012 CHHF10018
SDS Max
Spline
4" Hex
Flat Chisel
Model No.
CHPLBP10 CHMXBP12 CHMXBP18 CHSPBP12 CHSPBP18 CHHBP12 CHHBP18
Model No.
CHMXAC35016 CHHAC35016
Drill Bits
Asphalt Cutter
Model No.
CHSPCS53716 CHHCS53716
16 16
Clay Spade
221
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Model No.
CHMXSC15012 CHMXSC20012 CHMXSC30012 CHSPSC15012 CHSPSC20012 CHSPSC30012 CHHSC20012 CHHSC30012
Model No.
CHMXRD08710 CHSPRD08710
8 8
Scaler Brushing Tools: One Piece Concrete and Asphalt Surface Roughening
Shank Type SDS-Max Spline " Hex Head Width (in.) 1 34 1 4
3
Model No.
CHMXBT17509 CHSPBT17509 CHHBT17509
1 34
Model No.
CBMX15011 CBMX15022 CBMX20011 CBMX20022 CBMX26211 CBMX26222 CBMX35022 CBMX40011 CBMX40022 CBMX50011 CBMX50022
Model No.
CBSP15012 CBSP15022 CBSP20011 CBSP20022 CBSP26211 CBSP26222 CBSP31211 CBSP31222 CBSP35011 CBSP35022 CBSP50011 CBSP50022
Drill Bits
258 3 4 5
16 614 16
22 1138 22
614 16 4
3
614 1634
NOTE: With 1 piece bits, once coring is begun the centering bit must be removed using ejector pin. Core bit bodies are 21116" deep.
Ejector Key
Dia. (in.)
3
16
222
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Shaft Breakage behind the head: If the break area shows jagged steel and no notch, the bit has been over-torqued by jamming in the hole. The bit is not covered by warranty.
Shank transition area on upper shaft is polished: This is a positive indication that the bit has been used to produce deeper holes than it should. This means that debris has not been able to clear the hole readily, producing excessive heat buildup, which destroyed the bit-no warranty replacement. (User should purchase longer bits or use a lighter-duty hammer with small diameter bits).
Tool holder slots, dimples, or recesses show wear: This indicates the hammer tool holder should be repaired or replaced-no warranty replacement.
Drill Bits
223
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
MECHANICAL ANCHORS
M1. Pre-Load Relaxation Expansion anchors that have been set to the required installation torque in concrete will experience a reduction in pre-tension (due to torque) within several hours. This is known as pre-load relaxation. The high compression stresses placed on the concrete cause it to deform which results in a relaxation of the pre-tension force in the anchor. Tension in this context refers to the internal stresses induced in the anchor as a result of applied torque and does not refer to anchor capacity. Historical data shows it is normal for the initial tension values to decrease by as much as 4060% within the rst few hours after installation. Retorquing the anchor to the initial installation torque is not recommended, or necessary.
224
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Acrylic Adhesives
Insert Acceptable Hole Acceptable Load Diameter Diameter Range Reduction Factor (in.) (in.)
3 1
2 8 3 4 7 8 1
2 34 8 1516 3 4 118 7 8 1516 1 112 1 1 8 11116 114 178 138 2116 112 214
1 5
8 2 5 8 3 4 7 8 1
16 12 16 58 11 16 34 13 16 78 1 1116 118
7 9
The performance data for adhesive anchors are based upon anchor tests in which holes were drilled with carbide-tipped drill bits of the same diameter listed in the products load table. Additional static tension tests were conducted to qualify anchors installed with SET, SET-XP, EDOT and AT adhesives for installation in holes with diameters larger than those listed in the load tables. The tables indicate the acceptable range of drilled-hole sizes and the corresponding allowable tension-load reduction factor (if any). The same conclusions also apply to the published allowable shear load values. Drilled holes outside of the range shown below are not recommended.
Damp Hole - A damp hole, as dened in ASTM E1512 and referenced in ICC-ES AC58, is a drilled hole that has been properly drilled, cleaned and then is lled with standing water for seven days. After seven days, the standing water is blown out of the hole with compressed air and the adhesive anchor is installed. Water-Filled Hole - A water-lled hole is dened similarly to a damp hole; however, the standing water is not blown out of the hole. Instead, the adhesive is injected directly into the water-lled hole (from the bottom of the hole up) and the insert is installed. Submerged Hole - A submerged hole is similar to a water-lled hole with one major exception in addition to standing water within the hole; water also completely covers the surface of the base material as well. Note that drilling debris and sludge should be removed from the drilled hole prior to installation. ASTM E1512 and ICC-ES AC58 do not address this condition.
SET-XP adhesive: The performance data for adhesive anchors using SET-XP epoxy anchoring adhesive are based upon tests according to ICC-ES AC308. This criterion requires adhesive anchors that are to be installed in outdoor environments to be tested in water-saturated concrete holes that have been cleaned with less than the amount of hole cleaning recommended by the manufacturer. A products sensitivity to this installation condition is considered in determining the products Anchor Category (strength reduction factor). SET-XP may be installed in dry or water-saturated concrete. Based on Reliability Testing per ICC-ES AC308 Dry Concrete Cured concrete whose moisture content is in equilibrium with surrounding non-precipitate atmospheric conditions. Water-Saturated Concrete Cured concrete whose internal aggregate materials are soaked with moisture. Submerged Concrete Cured concrete that is covered with water and water saturated. Water-Filled Hole Drilled hole in water-saturated concrete that is clean yet contains standing water at the time of installation. SET, ET-HP, EDOT, AT and VGC: The performance data for adhesive anchors using SET, ET-HP, EDOT, AT and VGC adhesives are based upon tests in which anchors are installed in dry holes. Additional static tension tests were conducted for some products in damp holes, water-lled holes and submerged holes. The test results show that no reduction of the published allowable tension load is necessary for SET, ET-HP, EDOT, and AT adhesives in damp holes, or for SET and AT adhesives in water-lled holes. For SET, ET-HP, and AT adhesives in submerged holes, the test results show that a reduction factor of 0.60 is applicable. The same conclusions also apply to the published allowable shear load values. Based on Service Condition Testing per ICC-ES AC58 Dry Concrete Cured concrete whose moisture content is in equilibrium with surrounding non-precipitate atmospheric conditions.
225
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
For some anchors, the average ultimate load and/or allowable load is also controlled by anchor displacement limits. The allowable loads for steel inserts used with adhesive anchors is determined as follows: For threaded rod: Tallowable = 0.33 FuAg ; Vallowable = 0.17FuAg For Grade 60 rebar: Tallowable = (24,000 psi)Ag ; Vallowable = 0.17(90,000 psi)Ag Where: Ag = Gross cross-sectional area of the insert Threaded Insert Steel Type F1554, Grade 36 A193, Grade B7 304/316 Stainless (Diam. 58") 304/316 Stainless (Diam 34") Where: Fu = Ultimate tensile strength of steel insert Fu (psi) 58,000 125,000 100,000 85,000
Linear interpolation of allowable loads between embedment depths and/ or compressive strengths shown in the load tables is permitted. Linear interpolation of load-adjustment factors in the edge distance and spacing tables is also permitted.
(Under ACI 318 APPENDIX D, ICC-ES AC193, and ICC-ES AC308) determined per ACI 318 Appendix D, AC193, AC308 and the IBC. Vn = Lowest design strength of an anchor or anchor group in shear as determined per ACI 318 Appendix D, AC193, AC308 and the IBC. = Conversion factor calculated as a weighted average of the load factors for the controlling load combination. In addition, shall include all applicable factors to account for non-ductile failure modes and required over-strength. Interaction shall be calculated as follows: For tension loads, T 0.2Tallowable, the full allowable load in shear shall be permitted. For shear loads, V 0.2Vallowable, the full allowable load in tension shall be permitted. For all other cases: T Tallowable + V Vallowable 1.2
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
In strength design (SD), the Designer must size the anchorage such that the required strength (i.e. factored load) does not exceed the lowest design strength of the anchor or anchor group considering all possible failure modes.
Nua Nn Vua Vn
Calculations are performed in accordance with the applicable design standards: ICC-ES AC193 and ACI 318 Appendix D for mechanical anchors and ICC-ES AC308 for adhesive anchors. The additional design provisions of AC308 are shown elsewhere in this catalog. The nominal strengths and design data in this catalog are derived from fullscale testing and calculations in accordance with ACI 355.2, ICC-ES AC193 and ICC-ES AC308. In general, nominal strengths are 5% fractile strengths calculated using the average ultimate load, and standard deviation of full-scale test results. A 5% fractile strength is the nominal strength for which there is a 90% condence that there is a 95% probability of the actual strength exceeding the nominal strength. For anchors that are designed using ACI 318 Appendix D, AC193, or AC308, it is possible to convert design strengths (i.e. Nn or Vn) to allowable loads using the following approach from AC193 (dated February 2008) and AC308 (dated January 2009): N V Tallowable, ASD = n and Vallowable, ASD = n Where: Tallowable,ASD = Allowable tension load Vallowable,ASD = Allowable shear load 226 Nn = Lowest design strength of an anchor or anchor group in tension as
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
(D-16a)
(D-16b)
(D-16c)
(D-16d) (D-16e)
D.5.3.9 - The basic strength of a single adhesive anchor in tension in cracked concrete shall not exceed Na0 = k,cr ..d.hef (D-16f)
227
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
D.5.3.14 - When an adhesive anchor or a group of adhesive anchors is located in a region of a concrete member where analysis indicates no cracking at service load levels, the modication factor p,Na shall be taken as p,Na = 1.0 when ca,min cac (D-16o)
[(
s scr,Na
0.5
(1 g,Na0 )
(D-16g)
where
g,Na0
(D-16h)
p,Na = max
|ca,min; ccr,Na |
cac
= n - ( n - 1)
( ) ] 1.0
1.5
k,max,cr
k,cr
k,cr is the characteristic bond strength in cracked concrete having strength 'c evaluated from tests per AC308. k,max,cr = .d kc,cr hef . 'c (D-16i)
For all other cases p,Na = 1.0. D.6.3.2 - The nominal pryout strength of an adhesive anchor Vcp or group of adhesive anchors Vcpg shall not exceed (a) for a single adhesive anchor Vcp = min kcp .Na ; kcp .Ncb
kc,cr = 17 whereby the value of kc,cr shall be permitted to be increased to a maximum value based on the results of tests in cracked concrete in accordance with AC308 D.5.3.11 - The modication factor for eccentrically loaded adhesive anchor groups is ec,Na = 1 1.0 1+ 2e'N scr,Na (D-16j)
| |
(D-30a)
where
(D-30b)
kcp = 1.0 for hef < 2.5 in. kcp = 2.0 for hef 2.5 in. Na is calculated in accordance with Eq. (D-16a) Nag is calculated in accordance with Eq. (D-16b) Ncb , Ncbg are determined in accordance with D.5.2.9 D.8.8 - For adhesive anchors that will remain untorqued, the minimum edge distance shall be based on minimum cover requirements for reinforcement in 7.7. For adhesive anchors that will be torqued, the minimum edge distance and spacing shall be taken as 6do and 5do, respectively, unless otherwise determined in accordance with AC308. NOTE: Bond strength determination: Bond strength values are a function of the special-inspection level provided and installation conditions. Bond strength values must be modied with the factor Ksat for cases where the holes are drilled in water-saturated concrete as follows:
Special Inspection Level Continuous Continuous Periodic Periodic Permissible Installation Condition Dry Concrete Water-saturated Dry Concrete Water-saturated Bond Strength k k x Ksat,ci k k x Ksat,pi Associated Strength Reduction Factor dry,ci sat,ci dry,pi sat,pi C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
If the loading on an anchor group is such that only some anchors are in tension, only those anchors that are in tension shall be considered when determining the eccentricity e'N for use in Eq. (D-16j). In the case where eccentric loading exists about two othogonal axes, the modication factor ec,Na shall be computed for each axis individually and the product of these factors used as ec,Na in Eq. (D-16b). D.5.3.12 - The modication factor for edge effects for single adhesive anchors or anchor groups loaded in tension is
ed,Na
= 1.0
when ca,min ccr,Na ca,min 1.0 when ca,min < ccr,Na ccr,Na
(D-16l)
ed,Na
0.7 + 0.3
(D-16m)
D.5.3.13 - When an adhesive anchor or a group of adhesive anchors is located in a region of a concrete member where analysis indicates no cracking at service load levels, the nominal strength Na or Nag of a single adhesive anchor or a group of adhesive anchors shall be calculated according to Eq. (D-16a) and Eq. (D-16b) with k,uncr substituted for k,cr in the calculation of the basic strength Na0 in accordance with Eq. (D-16f) k,uncr shall be established based on tests in accordance with AC308. The factor g,Na0 shall be calculated in accordance with Eq. (D-16h) whereby the value of k,max,uncr shall be calculated in accordance with Eq. (D-16n) and substituted for k,max,cr in Eq. (D-16h) k,max,uncr = kc,uncr hef . f'c .d
(D-16n)
Where applicable, the modied bond strengths must be used in lieu of k,cr or k,uncr in AC308 Equations (D-16a) and (D-16b). The resulting nominal bond strength must be multiplied by the strength-reduction factor for the special-inspection level listed above. The various factors are given in Tables 5A and 5B of ESR-2508 and page 17 and 18 of this catalog.
228
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Traditional ASD
No Yes No Yes No Yes Yes Yes
ICC-ES AC308
Yes N/A4 Yes N/A4 Yes N/A4 Yes N/A4
1. Concrete includes all concrete base materials such as concrete on metal deck and precast concrete shapes. 2. Masonry includes all masonry base materials such as hollow and grout-filled CMU and unreinforced brick masonry. 3. Code interpretations vary. Confirm with the local Building Official. 4. Not applicable since masonry is beyond the scope of this design method.
Building codes and material standards have traditionally allowed Designers to take a one third allowablestress increase on the calculated design capacities of some building materials and components when designing for forces generated from wind and/or seismic events. Newer codes and standards only allow the allowable stress increase to be taken when using an alternate set of load combinations. The table below summarizes when allowable-stress increases are permitted.
1
Is 13 Allowable Stress Increase Permitted for PostInstalled Anchors Designed with Traditional ASD? N/A3 Yes4 N/A3 Yes4 N/A3 Yes4 Yes4 Yes4
Concrete1
2
Concrete1
2
2000 IBC/IRC
Concrete1
2
1. Concrete includes all concrete base materials such as reinforced concrete, concrete on metal deck and precast concrete shapes. 2. Masonry includes all masonry base materials such as hollow and grout-filled CMU and unreinforced clay-brick masonry. 3. Not applicable since this code does not use traditional ASD for post-installed anchors. 4. Only when indicated in the applicable load table in this catalog and when alternative basic load combinations as prescribed in the code are used.
229
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Cracked X3
X X X
X X X
X3 X
3
1. Allowable loads for traditional ASD are derived from applicable test methods such as ASTM E488, ASTM E1512 and legacy ICC-ES acceptance criteria AC58 and AC60. 2. Code listings may not be available for all products/applications cited in the table. To verify code listed products/applications refer to code reports at www.strongtie.com or contact SimpsonStrongTie at (800) 999-5099 (U.S. and Canada). 3. Installed into top surface. 4. Unreinforced clay brick masonry.
Design Methods Covered Mechanical Anchors Traditional ASD1 ASD Torq-Cut Strong-Bolt Strong-Bolt 2
Cracked X X X X
Code Listings2
X X X X X X X
Sleeve-All
1. Allowable loads for traditional ASD are derived from applicable test methods such as ASTM E488, ASTM E1512 and legacy ICC-ES acceptance criteria AC01, AC70, and AC106. 2. Code listings may not be available for all products/applications cited in the table. To verify code listed products/applications refer to code reports at www.strongtie.com or contact SimpsonStrongTie at (800) 999-5099 (U.S. and Canada).
230
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
The allowable tension (or shear) value for a group of anchors is equal to the lowest (minimum) tension (or shear) value for a single anchor within the group multiplied by the number of anchors within the group.
Figure 1
Tension Ratio,
T Tall
Shear Ratio,
V Vall
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
ADDITIONAL DATA: Embedment depth = 512" Spacing = Sact = S1 = 8". Critical spacing for 34" dia. anchor at embedment = Scr = 12". Sact < Scr therefore use spacing reduction factor for S1. End distance = Cact = C1 = 4" Edge distance = Cact = C2 = 12" Critical edge distance = Ccr = 12". Critical end distance = Ccr = 12". C1 < Ccr, therefore use perpendicular-to-edge reduction factor for C1. C2 > Ccr, therefore no edge reduction factor for C2. SOLUTION: TENSION Determine uninuenced allowable tension load in the face of an 8" normal wt. concrete grouted CMU wall: Uninuenced allowable tension = 1,600 lbs. Calculate reduced efciency factors for Edge Distance: Cact = C1 = 4" Cact = C2 = 12" fcC1 = 0.66 = Load adjustment factor (page 130) Calculate reduced efciency factor for spacing: Sact = S1 = 8" fsS1 = 0.67 = Load adjustment factor (page 130) Calculate allowable tension load per anchor: Allowable tension = (uninuenced allowable tension) (fcC1)(fsS1) Allowable tension = (1,600 lbs.)(0.66)(0.67)= 708 lbs. per anchor For a group of 2 anchors the combined allowable tension value is: = (2 anchors)(708 lbs./anchor) = 1,416 lbs. > 600 lbs. (design tension) O.K. SHEAR Determine uninuenced allowable shear load in the face of an 8" normal wt. concrete grouted CMU wall: Uninuenced allowable shear = 3,000 lbs. Calculate reduced efciency factor for end distance: Cact = C1 = 4" Cact = C2 = 12" fcC1 = 0.21 = Load adjustment factor (page 130) Calculate reduced efciency factor for spacing: Sact = S1 = 8" fsS1 = 0.75 = Load adjustment factor (page 130) Calculate allowable shear load per anchor: Allowable shear = (uninuenced allowable shear) (fcC1)(fsS1) Allowable shear = (3,000 lbs.)(0.21)(0.75) = 473 lbs. per anchor For a group of 2 anchors the combined allowable shear value is: = (2 anchors)(473 lbs./anchor) = 945 lbs. > 500 lbs. (design shear) O.K.
C2 = 12"
The allowable tension (or shear) value for a group of anchors is equal to the lowest (minimum) tension (or shear) value for a single anchor within the group multiplied by the number of anchors within the group.
CHECK COMBINED TENSION AND SHEAR INTERACTION: For the Titen HD in grouted CMU, use the straight-line method (n = 1, see Figure 1) when calculating the interaction of both tension and shear upon the anchor per the following equation: (Design shear/Allowable shear)n + (Design tension/Allowable tension)n 1.0, n = 1 Design shear (V) = 500 lbs. Allowable shear (Vall) = 945 lbs. Design tension (T) = 600 lbs. Allowable tension (Tall) = 1,416 lbs. (600/1,416)1 + (500/945)1 = 0.95 1.0 O.K.
Figure 1
Tension Ratio,
Shear Ratio,
V Vall
Note: The elliptical method permits greater allowable tension and shear loads to be used than the straight-line method. 232
T Tall
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
4"
REFERENCE
CALCULATIONS AND DISCUSSION 4. Concrete breakout capacity under tension loading: Ncb Nua A Ncb = Nc ed,N c,N cp,N Nb ANco where:
Note: Calculations are performed in accordance with ACI 318-08. 1. Determine the factored tension and shear design loads: Nua = 1.6W = 1.6 x 1,000 = 1,600 lb. Vua = 1.6W = 1.6 x 350 = 560 lb. 2. Design considerations: This is a combined tension and shear interaction problem where values for both Nn and Vn need to be determined. Nn is the lesser of the design tension strength controlled by: steel (Nsa), concrete breakout (Ncb), or pull-out (nNpn). Vn is the lesser of the design shear strength controlled by: steel (Vsa), concrete breakout (Vcb), or pryout (Vcp). 3. Steel capacity under tension Loading:
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
D.4.1.2
Nb = kc 'c hef1.5 substituting: A Ncb = Nc ed,N c,N cp,N kc 'c hef1.5 A Nco where: kc = kcr = 17 (Anchor is installed in a tension zone, therefore, cracking is assumed at service loads
Eq. (D-7)
This catalog
Nsa Nua Nsa = 12,100 lb. = 0.75 n = 1 (single anchor) Calculating for Nsa: Nsa = 0.75 x 1 x 12,100 = 9,075 lb. > 1,600 lb. OK
ed,N = 0.7 + 0.3 ca,min when ca,min < 1.5 hef 1.5hef by observation, ca,min = 4 < 1.5hef
cp,N = 1.0
(4) ed,N = 0.7 + 0.3 = 0.94 1.5(3.375) c,N = 1.0 assuming cracking at service loads (ft > fr) = 0.65 for Condition B (no supplementary reinforcement provided) ANco = 9hef 2 = 9(3.375)2 = 102.52 in.2 D.5.2.6 This catalog Eq. (D-6)
Would you like help with these calculations? Visit www.strongtie.com to download the SimpsonStrongTie Anchor Selector software.
ANc = (ca1 + 1.5hef)(2 x 1.5hef) = (4 + 1.5(3.375))(2 x 1.5(3.375)) = 91.76 in.2 ANc 91.76 = = 0.90 ANco 102.52 Calculating for Ncb: Ncb = 0.65 x 0.90 x 0.94 x 1.0 x 1.0 x 17 x 1.0 x
Fig. RD.5.2.1(a)
233
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Pullout capacity, Np,cr, is established by reference tests in cracked concrete by the reliability test of ACI 355.2. Data from the anchor prequalication testing must be used. Reference Strong-Bolt 2 anchor "characteristic tension design values" table for the 5 percent fractile value, Np,cr. Npn Nua Np,cr = 3,735 x = 0.65
Vcp = kcp Ncb where: n=1 kcp = 2.0 and = 0.70 3,175 = 9,769 lb. kcp Ncb = 2.0 x 0.65 nVcp = 0.70 x 1 x 9,769 = 6,838 lb. > 560 lb. OK 10. Check all failure modes under shear Loading: Summary: Steel capacity = 4,703 lb.
3,000 2,500
0.5
Npn = 0.65 x 4,091 = 2,659 lb. > 1,600 lb. OK 6. Check all failure modes under tension loading: Summary: Steel capacity = 9,075 lb. Concrete breakout capacity = 3,175 lb. Pullout capacity = 2,659 lb. Controls Nn = 2,659 lb. as pullout capacity controls 7. Steel capacity under shear loading: Vsa Vua Vsa = 7,235 lb. = 0.65 Calculating for Vsa: D.6.1 Eq. (D-2) This catalog This catalog
D.4.1.2
Concrete breakout capacity = 2,224 lb. Controls Pryout capacity = 6,838 lb.
Vn = 2,224 lb. as concrete breakout capacity controls 11. Check interaction of tension and shear forces: If 0.2 Vn Vua, then the full tension design strength is permitted. By observation, this is not the case. If 0.2 Nn Nua, then the full shear design strength is permitted By observation, this is not the case. Therefore: Eq. (D-31)
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Vsa = 0.65 x 7,235 = 4,703 lb. > 560 lb. OK 8. Concrete breakout capacity under shear loading: Vcb Vua A Vcb = Vc ed,V c,V h,v Vb AVco where: da 'c ca11.5 Vb = 7 da substituting: A Vcb = Vc ed,V c,V h,v 7 e AVco da where: D.6.2 Eq. (D-2) Eq. (D-21) D.7 D.7.1
( )
e
0.2
Eq. (D-24)
D.7.2
( )
0.2
da 'c ca11.5
V Nua + ua 1.2 Nn Vn 1,600 + 560 = 0.60 + 0.25 = 0.85 < 1.2 OK 2,659 2,224
= 0.70 for Condition B (no supplementary reinforcement provided) AVco = 4.5ca1 = 4.5(4)2 AVco = 72 in.2
2
12. Summary Fig. RD.6.2.1(a) A single 12" diameter carbon-steel Strong-Bolt 2 anchor at a 378" embedment depth is adequate to resist the applied service tension and shear loads of 1,000 lb. and 350 lb., respectively.
AVc = 2(1.5ca1)(1.5ca1) = 2(1.5(4))(1.5(4)) AVc = 72 in.2 AVc = 72 = 1 AVco 72 h = 12 in. a = 1.0 since h > 1.5 C h,v a a1 ed,V = 1.0 since ca2 > 1.5ca1 c,V = 1.0 assuming cracking at service loads (ft > fr) da = 0.5 in.
e = 3.375 in.
D.6.2.1
D.6.2.2 8.6.1
234
3.375 0.2 x 0.5 x 1.0 Vcb = 0.70 x 1 x 1.0 x 1.0 x1.0 x 7 x 0.5 x 3,000 x (4)1.5 = 2,224 lb. > 560 lb. OK
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
134"
CALCULATIONS AND DISCUSSION 4. Concrete breakout capacity under tension loading: Ncb Nua A Ncb = Nc ed,N c,N cp,N Nb ANco where:
Note: Calculations are performed in accordance with ICC-ES AC308 and ACI 318-08. 1. Determine the factored tension and shear design loads: Nua = 1.6W = 1.6 x 650 = 1,040 lb. Vua = 1.6W = 1.6 x 275 = 440 lb. 2. Design considerations: This is a combined tension and shear interaction problem where values for both Nn and Vn need to be determined. Nn is the lesser of the design tension strength controlled by: steel (Nsa), concrete breakout (Ncb), or adhesive (Na). Vn is the lesser of the design shear strength controlled by: steel (Vsa), concrete breakout (Vcb), or pryout (Vcp). 3. Steel capacity under tension loading: Nsa Nua Nsa = 17,750 lb. = 0.75 n = 1 (single anchor) Calculating for Nsa: Nsa = 0.75 x 1 x 17,750 = 13,313 lb. > 1,040 lb. OK D.5.1 Eq. (D-1) This catalog This catalog D.4.1.2 ACI 318, 9.2.1
Nb = kc'c hef1.5 substituting: A Ncb = Nc ed,N c,N cp,N kc'c hef1.5 A Nco where: kc = kcr = 17 = 1.0 for normal-weight concrete cp,N = 1.0 c ed,N = 0.7 + 0.3 a,min when ca,min < 1.5 hef 1.5hef by observation, ca,min < 1.5hef
Eq. (D-7)
Eq. (D-11)
1.75 ed,N = 0.7 + 0.3 = 0.78 1.5(4.5) c,N = 1.0 = 0.65 for Condition B (no supplementary reinforcement provided) ANco = 9hef 2 = 9(4.5)2 = 182.25 in.2 ANc = (ca1 + 1.5hef)(2 x 1.5hef) = (1.75 + 1.5(4.5))(2 x 1.5(4.5)) = 114.75 in.2 ANc 114.75 = = 0.63 A 182.25 Nco f'c = 2,500 psi Calculating for Ncb: Ncb = 0.65 x 0.63 x 1.0 x 0.78 x 1.0 x 17 x 1.0 x 2,500 x (4.5)1.5 = 2,592 lb. > 1,040 lb. OK D.5.2.6 This catalog Eq. (D-6)
Would you like help with these calculations? Visit www.strongtie.com to download the SimpsonStrongTie Anchor Selector software.
Fig. RD.5.2.1(a)
235
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
( )
0.2
Eq. (D-24)
scr,Na = (20)(0.5)
( )
0.2
da 'c ca11.5
= 0.70 for Condition B (no supplementary reinforcement provided) AVco = 4.5ca12 = 4.5(1.75)2 AVco = 13.78 in.2 AVc = 2(1.5ca1)(1.5ca1) = 2(1.5(1.75))(1.5(1.75)) AVc = 13.78 in.2 AVc = 13.78 = 1 AVco 13.78 ha = 12 in.
ANa = (ca1 + ccr,Na)(scr,Na) = (1.75 + 6.23)(12.46) = 99.43 in2 c = (0.7 + 0.3 c a,min) 1.0 Since ca,min < ccr,Na Eq. (D-16m) ed,Na cr,Na
ed,Na
c 1.75 = (0.7 + 0.3 c a,min ) = (0.7 + 0.3 ) = 0.78 6.23 cr,Na AC308 D.5.3.14 This catalog
Fig. RD.6.2.1(a)
p,Na
= 1.0
D.6.2.1
Calculating for Na: N = 0.65x 99.43 x0.78x1.0x7,033 = 2,284 lb. > 1,040 lb. OK a 155.25 6. Check all failure modes under tension loading: D.4.1.2
h,v = 1.0 since ha > 1.5 ca1 D.6.2.8 ed,V = 1.0 since ca2 > 1.5ca1 c,V = 1.0 for cracked concrete da = 0.5 in.
e = 8da = 8 (0.5) = 4"
8.6.1
4 0.2 x 0.5 x 1.0 Vcb = 0.70 x 1 x 1.0 x 1.0 x 1.0 x 7 x 0.5 x 3,000 x (1.75)1.5 = 666 lb. > 440 lb. OK
( )
9. Concrete pryout capacity per AC308 Vcp = min[kcpNa; kcpNcb] kcp = 2.0 for hef 2.5" Na = 3,514 lb. from adhesive-capacity calculation without factor Ncb = 3,988 lb. from concrete-breakout calculation without factor Vcp = (2.0)(3,514) = 7,028 lb. controls = 0.7 Vcp = (0.7)(7,028) = 4,920 lb. > 440 lb. OK This catalog Eq. (D-30a)
236
Summary: Steel capacity = 13,313 lb. Concrete breakout capacity = 2,592 lb. Controls Adhesive capacity = 2,284 lb. Nn = 2,284 lb. as concrete breakout capacity controls
D.6.2.2
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Concrete breakout capacity = 666 lb. Controls Pryout capacity = 4,920 lb.
Vn = 666 lb. as concrete breakout capacity controls 11. Check interaction of tension and shear forces: If 0.2 Vn Vua, then the full tension design strength is permitted. By observation, this is not the case. If 0.2 Nn Nua, then the full shear design strength is permitted By observation, this is not the case. Therefore: Eq. (D-31) D.7.2 D.7 D.7.1
Nua V + ua 1.2 Nn Vn 1,040 + 440 = 0.46 + 0.66 = 1.12 < 1.2 OK 2,284 666
12. Summary A single 12" diameter ASTM A193 Grade B7 anchor rod in SET-XP epoxy adhesive at a 412" embedment depth is adequate to resist the applied service tension and shear loads of 650 lb. and 275 lb., respectively.
237
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
EFFECTIVE EMBEDMENT DEPTH - The dimension measured from the concrete surface to the deepest point at which the anchor tension load is transferred to the concrete. EMBEDMENT DEPTH - The distance from the top surface of the base material to the installed end of the anchor. In the case of a post-installed mechanical anchor, the embedment depth is measured prior to application of the installation torque. EPOXY - A thermosetting resin made by combining mainly Dyglycydal Ether or Bisphenol-A and a Polyamine curing agent. EXPANSION ANCHOR - A mechanical fastener placed in hardened concrete or assembled masonry, designed to expand in a self-drilled or predrilled hole of a specied size and engage the sides of the hole in one or more locations to develop shear and/or tension resistance to applied loads without grout, adhesive or drypack. FATIGUE LOAD TEST - A test in which the anchor is subjected to a specied load magnitude for 2 x 106 cycles in order to establish the endurance limit of the anchor. GEL TIME - The elapsed time at which an adhesive begins to increase in viscosity and becomes resistant to ow. GREEN CONCRETE - Concrete that has cured for less than 28 days. GROUT - A mixture of cementitious material and aggregate to which sufcient water is added to produce pouring consistency without segregation of the constituents. GROUTED MASONRY (or GROUT-FILLED MASONRY) Hollow-unit masonry in which the cells are lled solidly with grout. Also, double or triple-wythe wall construction in which the cavity(s) or collar joint(s) is lled solidly with grout. HOT-DIP GALVANIZED - A part coated with a relatively thick layer of zinc by means of dipping the part in molten zinc. Hot-dip galvanizing provides a medium level of corrosion resistance. ICC ES - International Code Council Evaluation Service. LIGHTWEIGHT CONCRETE - Concrete containing lightweight aggregate. The unit weight of lightweight concrete is not to exceed 115 pcf. MASONRY - Brick, structural clay tile, stone, concrete masonry units or a combination thereof bonded together with mortar. MECHANICALLY GALVANIZED - A part coated with a layer of zinc by means of mechanical impact. The thickest levels of mechanical galvanizing (ASTM B695, Class 55 or greater) are considered to be alternatives to hot-dip galvanizing and provide a medium level of corrosion resistance MERCAPTAN - An ingredient used in epoxy as a curing agent. MORTAR - A mixture of cementitious materials, ne aggregate, and water, used to bond masonry units together. Nominal strength - The strength of an element as calculated per ACI 318, ICC-ES AC193 or ICC-ES AC308. NORMAL WEIGHT CONCRETE - Concrete containing normal weight aggregate. The unit weight of normal weight concrete is approximately 150 pcf.
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
STAINLESS STEEL - A family of iron alloys containing a minimum of 12% chromium. Stainless steels have a high level of corrosion resistance. Type 316 stainless steel provides greater corrosion resistance than Types 303 or 304. 239
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Special Section
Introducing
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SCB
All our standard slide clips accommodate 1" of both upward and downward movement, equivalent to an L/360 live-load deection for a 30' span. Our standard clips also accommodate stand-offs as large as 12". For deections greater than 1", or stand-offs greater than 12", SimpsonStrongTie can provide custom clips to suit most framing needs (see page 12). Our SCB and SCW slide-clip connectors can be manufactured for 138" of both upward and downward movement. Please call us for information about this option.
SSB
FCB
Designers of curtain walls will often know the capacity of a connector, but since the capacity does not take into account the way in which the connector is anchored to the supporting structure, the Designer must then manually calculate this important aspect of the connection design. These calculations are complicated by considerations of eccentric and prying forces that often exist but are difcult to predict. Through comprehensive testing SimpsonStrongTie provides total, code-listed connector solutions. Our testing extends from the capacity of the connector and its attachment to the framing, to the anchorage of the connector to the primary structure. By providing complete data on the entire connection system, we save the Designer time and ensure that all forces, including eccentric and prying forces, are adequately considered. As with all SimpsonStrongTie products, our slide-clip and xed-clip connectors for curtain-wall steel stud framing carry our promise of quality and performance, and are backed by prompt, knowledgeable service. The following information is effective until December 31, 2012. After this date, visit www.strongtie.com for updated information For other pertinent information, please refer to the Important Information and General Notes pages in the current SimpsonStrongTie Cold-Formed Steel Connectors for Residential and MidRise Construction catalog. For limited warranty information and terms and conditions of sale, please visit www.strongtie.com. For special orders, call us at (800) 999-5099. Code Listed: IAPMO ES ER-238
SCW
241
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
General Notes
General Notes for Allowable Connector Load Tables
1. Allowable loads are for use when utilizing the traditional Allowable Stress Design methodology. Contact SimpsonStrongTie for LRFD loads. 2. Allowable loads are based on cold-formed steel members with a minimum yield strength, Fy, of 33 ksi and tensile strength, Fu, of 45 ksi for 43 mils (18 ga.) and thinner, and a minimum yield strength of 50 ksi and tensile strength of 65 ksi for 54 mils (16 ga.) and thicker. 3. The tabulated values for 54 mil (16 ga.) are applicable for framing members thicker than 54 mil (16 ga.) with a minimum yield strength of 50 ksi and tensile strength of 65 ksi. 4. Allowable loads for the SCB, SCW and SSB connectors are based on #14 shouldered screws (provided with connectors) installed in the center of the slots. 5. Allowable loads may not be increased for wind or seismic load. 6. Clips do not replace stud lateral or stability bracing. Design of bracing is the responsibility of the Designer. 7. It is the responsibility of the Designer to verify the adequacy of the stud. Allowable loads are based on clips installed an adequate distance away from penetrations, notches, ends of studs and other conditions that may affect the clip performance. 8. Industry studies show that hardened fasteners can experience performance problems in wet or corrosive environments. Accordingly, use these products in dry and non-corrosive environments only.
In addition to self-drilling screws and welding, Simpson Strong-Tie connectors for curtain-wall construction are designed to be fastened with our powder-actuated fasteners and concrete screws.
242
For more information on our full line of anchoring and fastening systems for concrete and masonry, visit www.strongtie.com or reference our Anchoring and Fastening Systems for Concrete and Masonry catalog.
When It Comes to Fastening Curtain-Wall Clips with P.A.T. or Concrete Screws, We've Got You Covered
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SCB43.5
SCB45.5
SCB47.5
SCB49.5
4"
F2 F3 F2 F3
243
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
112"
2 22 3 22 3 22 3 22 3
975 975 1260 945 1260 945 1260 920 1260 SCB 214" 4"
1. For additional important information, see General Notes for Allowable Connector Load Tables on page 242. 2. When the SCB connector is used with 2 shouldered screws, the screws may be installed in any 2 slots. 3. Allowable loads are based on clips installed with (4) #12-14 screws in the anchor leg. For other anchorage installations, the capacity of the connection system will be the minimum of the tabulated value and the allowable load from the SCB Allowable Anchorage Loads table below.
2" Min.
F2 F3
2" Min.
Self-drilling screws shown. Other fasteners similar. Allowable Loads F2 and F3 795 1120 1260 280 390 555 380 445 510 1260 2 Anchors 3 Anchors 1" 2"
Welded
1. For additional important information, see General Notes for Allowable Anchorage Load Tables on page 242. 2. Allowable loads are for clip anchorage only. The capacity of the connection system will be the minimum of the tabulated value and the allowable load from the SCB Allowable Connector Loads table above.
4 Anchors
244
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
SCW3.25
4"
F4
F4 4 F
245
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
1. For additional important information, see General Notes for Allowable Connector Load Tables on page 242. 2. When the SCW5.5 connector is used with 2 shouldered screws, install screws in the outermost slots. 3. Allowable loads are based on clips installed with all holes in the anchor leg lled with #12-14 screws. For other anchorage installations, the capacity of the connection system will be the minimum of the tabulated value and the allowable load from the SCW Allowable Anchorage Loads table below.
W SCW
F4
Install shouldered screws adjacent to No-Equal stamp (typ.). Self-drilling screws shown; other fasteners similar.
1
SCW5.5 Installation with 2 Shouldered Screws (3 shouldered screws and SCW3.25 similar)
2 Anchors
F4
1. For additional important information, see General Notes for Allowable Anchorage Load Tables on page 242. 2. Allowable loads are for clip anchorage only. The capacity of the connection system will be the minimum of the tabulated value and the allowable load from the SCW Allowable Connector Loads table above.
3 Anchors
F4
2 Anchors 4 Anchors
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
4"
F2 F3
F2 F3
247
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
Stud Thickness 33 mil (20 ga.) F2 520 815 F3 520 815 43 mil (18 ga.) F2 690 1030 F3 690 1080 54 mil (16 ga.) F2 1075 1335 F3 960 1225
158" 312"
18"
SSB3.518
214" SSB
1. For additional important information, see General Notes for Allowable Connector Load Tables on page 242. 2. When the SSB connector is used with 2 shouldered screws, the screws may be installed in any 2 slots. 3. Allowable loads are based on clips installed with (3) #12-14 screws in the anchor leg. For other anchorage installations, the capacity of the connection system will be the minimum of the tabulated value and the allowable load from the SSB Allowable Anchorage Loads table below.
F2 F3
2" Min.
2" Min.
1335
Welded
1. For additional important information, see General Notes for Allowable Anchorage Load Tables on page 242. 2. Allowable loads are for clip anchorage only. The capacity of the connection system will be the minimum of the tabulated value and the allowable load from the SSB Allowable Connector Loads table above.
Free Side
F2 F3
Welded
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
FCB43.5
FCB49.5
FCB411.5 F4 F2 F3
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
F2 F3 F4 F4 F2 F3 F3 F2 F4 F2 F3
F4
Contact Simpson Strong-Tie for the availability of FCB load tables for steel-to-steel framing.
249
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
4"
F4
FCB411.5 54 (16)
1. For additional important information, see General Notes for Allowable Connector Load Tables on page 242. 2. Allowable loads for #12-14 self-drilling screws are based on a minimum Pss = 2560 lbs. and Pts = 2595 lbs. 3. Min. fastener quantity and load valuesll all round holes; max. fastener quantity and load valuesll all round and triangular holes. 4. Allowable loads are based on clip capacity only and do not consider anchorage. The capacity of the connection system will be the minimum of the tabulated value and the allowable load from the FCB Allowable Anchorage Loads table below.
1
F2 F3
FCB Installation with Max. Fasteners 2" Min. FCB Installation with Min. Fasteners
2" Min.
FCB47.5 Min. 255 280 365 165 190 340 165 190 260 365 Max. 445 490 890 290 330 595 295 335 455 1445
FCB49.5 Min. 185 200 350 120 135 245 120 140 190 365 Max. 265 295 535 175 195 355 175 200 275 1200
FCB411.5 Min. 120 135 275 75 85 145 215 100 280 365 Max. 190 380 125 140 255 125 145 195 860
C-SAS-2012 2012 Simpson Strong-Tie Company Inc.
795 1120 1585 280 390 555 380 445 510 1735
625 690 1255 410 465 840 415 470 645 1910
410 450 820 265 305 550 270 310 420 1925
210
Welded
1. For additional important information, see General Notes for Allowable Anchorage Load Tables on page 242. 2. Min. and max. refer to stud fasteners. See FCB Allowable Connector Loads table above. 3. Allowable loads are for clip anchorage only. The capacity of the connection system will be the minimum of the tabulated value and the allowable load from the FCB Allowable Connector Loads table above.
1" 2"
F4
2 Anchors 250 3 Anchors
F2 F3
4 Anchors Welded Free side of clip Hard side of clip
Simpson Strong-Tie Anchoring and Fastening Systems for Concrete and Masonry
TO OBTAIN A QUOTE:
Supply a CAD drawing in .dwg or .dxf format complete with all dimensions, hole diameter and centerline locations, bend angles, steel strength (min. Fy and Fu), thickness (mils and/or ga.) and finish: (galvanized to G90, G185) or SimpsonStrongTie gray paint (specify). Total shape and size up to a maximum of 48" x 48" (approx. 116" tolerance). SimpsonStrongTie does not provide product engineering or
load values for special-order custom clips and connectors. Contact SimpsonStrongTie for pricing information. For additional information please refer to Important Information and General Notes in the SimpsonStrongTie, Cold-Formed Steel Connectors for Residential and Mid-Rise Construction catalog.
SPECIFICATION EXAMPLE:
QUANTITY: XX pieces DIMENSIONS: Per the attached CAD drawing (.dwg or .dxf format) Drawing must be fully dimensioned, including: Overall dimensions Leg dimensions Bend angles (if required) Hole/slot sizes and centerlines (if required) MATERIAL SPECIFICATION: (Contact SimpsonStrongTie for availability) THICKNESS: 54 mil (16 ga.) STRENGTH: Min. Yield Strength (Fy) = 33 ksi, Min. Tensile Strength (Fu) = 45 ksi FINISH: Galvanized G90
251
Anchor Designer for Allowable Stress Design For applications where ACI 318 doesn't apply, we still have the original Anchor Designer for Allowable Stress Design Software. We'll continue to keep this program updated with the latest technical information so it can continue to be a valuable tool for anchor specication.
Both programs make it easy to select the correct anchorage for your application and both are available for FREE download from www.strongtie.com.
(800) 999-5099
www.strongtie.com