Professional Documents
Culture Documents
PS HOLLOWCORE PLANK
May 2010
50
Additional bearing
may be required.
15
Standard
End
Solid
End
Special End
Details
Shelf
End
Support across
Stanchions
Grout infill
Typical Construction
Composite Construction.
(Propping may be required)
Shuttering/
infill by M.C.
if required.
Cantilevered Plank
Parallel steels
Cantilevered planks
Dimension A
140
Min
190
Min
Tie reinforcement
in open cores.
Where planks span on to a wall from both sides a minimum wall thickness
of 190mm is recommended. Where a wall thickness of 190mm cannot be
achieved a tie should be provided at the support. (N.B. the wall thickness
should never be less than 140mm in this situation). In order to satisfy the
tolerance for this situation a narrow support should only be used at one
end of the plank. Note: A shared bearing can also be achieved by the use
of a metal 'bearing plate' together with the tie detail shown above.
Dim
B
75 Nominal
50 Minimum
50 Minimum
Data sheet PS
PS HOLLOWCORE PLANKS
May 2010
PS-75
Unit
PS-100
Ms=kNm/unit
Mu=kNm/unit
Vco=kN/unit
7.26
8.70
9.61
11.78
12.17
11.69
14.55
16.16
18.94
19.42
125.21
129.40
131.16
141.90
142.49
10w
6s+4w
10s
12s+4w
14s+2w
Unit
Ms=kNm/unit
Mu=kNm/unit
Vco=kN/unit
13.62
16.71
18.66
23.05
23.89
26.53
20.29
28.13
32.18
39.17
40.52
44.45
164.32
169.21
171.31
183.74
184.47
189.05
10w
6s+4w
10s
12s+4w
14s+2w
18s
1200
Area=88,650mm2
100
75
1200
I= 41,205,968mm4
Zt= 1,087,418mm3
Nat= 38mm
Area=117,150mm2
Zb= 1,110,475mm3
Nab= 37mm
Zt= 1,934,442mm3
Nat= 50mm
Zb= 1,972,758mm3
Nab= 50mm
I= 97,670,599mm4
PS-150L
2s+8w
4s+6w
6s+4w
8s+2w
10s
12s
PS-150H
Mu=kNm/1.2m
34.73
39.39
43.84
48.08
52.12
58.27
Vco=kN/1.2m
Unit
Ms=kNm/unit
Mu=kNm/unit
Vco=kN/unit
91.71
95.43
99.83
105.19
112.17
117.21
2s+8w
4s+6w
6s+4w
8s+2w
10s
12s
33.88
38.39
42.73
46.87
50.83
56.89
47.81
58.45
68.70
77.93
86.12
98.27
127.08
131.99
137.56
144.36
153.24
159.77
47.81
58.45
68.70
77.93
86.97
99.69
1200
120
120
1200
120
120
120
120
85mm Wide
Void
120
120
120
120
120
120
120
120
120
120
65mm Wide
Void
120
100
120
Area= 121,296mm2
50
50
100
120
150
120
150
Ms=kNm/1.2m
Unit
I= 298,566,250mm4
Area=144,159mm2
I= 306,423,085mm4
Zt= 4,047,290mm3
Nat= 74mm
Zt= 4,305,744mm3
Nat= 71mm
Zb= 3,916,621mm3
Nab= 76mm
Zb= 3,886,946mm3
Nab= 79mm
PS-150S
Ms=kNm/unit
Unit
10w
6s+4w
10s
12s+4w
14s+2w
18s
28.91
35.33
39.38
48.28
50.05
55.51
Mu=kNm/unit
Vco=kN/unit
36.63
53.74
64.57
85.91
89.94
101.32
229.16
234.96
237.48
251.95
252.95
258.32
150
1200
Area=174,950mm2
I= 332,303,065mm4
Zt= 4,405,635mm3
Nat= 75mm
Zb= 4,456,067mm3
Nab= 75mm
PS-200
PS-250
Unit
Ms=kNm/unit
Mu=kNm/unit
Vco=kN/unit
Unit
Ms=kNm/unit
Mu=kNm/unit
Vco=kN/unit
2s+6w
4s+4w
6s+2w
8s
10s
12s
49.87
57.16
64.15
70.83
81.03
90.46
58.71
75.65
91.73
107.25
132.91
155.50
141.61
148.63
156.45
167.47
176.27
184.02
2s+6w
4s+4w
6s+2w
8s
10s
12s
69.08
78.88
88.30
97.32
111.10
123.89
76.34
98.43
120.51
142.07
176.62
208.68
177.04
185.06
194.76
207.52
218.16
227.59
1200
150
150
150
150
100mm Wide
Void
150
150
150
150
150
150
150
150
100mm Wide
Void
200
150
50
50
150
150
200
150
Area=143,940mm2
I= 657,509,516mm4
Zt= 6,568,037mm3
Nat= 100mm
Zb= 6,582,169mm3
Nab= 100mm
Area= 166,940mm2
I= 1,196,260,970mm4
Zt= 9,583,076mm3
Nat= 125mm
Zb= 9,557,135mm3
Nab= 125mm
250
1200
150