Enterasys Matrix

DFE-Platinum Series
Hardware Installation Guide
Module 7G4202-60
Module 7G4282-41
P/N 9033911-02
Downloaded from www.Manualslib.com manuals search engine
Downloaded from www.Manualslib.com manuals search engine
i
NOTICE
Enterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthis
documentanditswebsitewithoutpriornotice.ThereadershouldinallcasesconsultEnterasys Networksto
determinewhetheranysuchchangeshavebeenmade.
Thehardware,firmware,orsoftwaredescribedinthisdocumentissubjecttochangewithoutnotice.
INNOEVENTSHALLENTERASYS NETWORKSBELIABLEFORANYINCIDENTAL,INDIRECT,SPECIAL,OR
CONSEQUENTIALDAMAGESWHATSOEVER(INCLUDINGBUTNOTLIMITEDTOLOSTPROFITS)ARISING
OUTOFORRELATEDTOTHISDOCUMENT,WEBSITE,ORTHEINFORMATIONCONTAINEDINTHEM,EVEN
IFENTERASYS NETWORKSHASBEENADVISEDOF,KNEWOF,ORSHOULDHAVEKNOWNOF,THE
POSSIBILITYOFSUCHDAMAGES.
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
2007EnterasysNetworks,Inc.Allrightsreserved..
PartNumber: 903391102 March 2007
ENTERASYS,ENTERASYS NETWORKS,ENTERASYSMATRIX,LANVIEW,NETSIGHT,WEBVIEW,andanylogos
associatedtherewith,aretrademarksorregisteredtrademarksofEnterasys Networks, Inc.,intheUnitedStatesand
othercountries.
Allotherproductnamesmentionedinthismanualmaybetrademarksorregisteredtrademarksoftheirrespective
companies.
DocumentationURL:http://www.enterasys.com/support/manuals
DocumentacionURL:http://www.enterasys.com/support/manuals
DokumentationimInternet:http://www.enterasys.com/support/manuals
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes
Personal vorgenommen werden.
Downloaded from www.Manualslib.com manuals search engine
ii
REGULATORY COMPLIANCE INFORMATION
FEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICE
ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)thisdevice
maynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterference
thatmaycauseundesiredoperation.
NOTE: ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaclassAdigitaldevice,pursuantto
Part15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhen
theequipmentisoperatedinacommercialenvironment.Thisequipmentuses,generates,andcanradiateradio
frequencyenergyandifnotinstalledinaccordancewiththeoperatorsmanual,maycauseharmfulinterferenceto
radiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseinterferenceinwhichcase
theuserwillberequiredtocorrecttheinterferenceathisownexpense.
WARNING: Changesormodificationsmadetothisdevicewhicharenotexpresslyapprovedbytheparty
responsibleforcompliancecouldvoidtheusersauthoritytooperatetheequipment.
INDUSTRY CANADA NOTICE
ThisdigitalapparatusdoesnotexceedtheclassAlimitsforradionoiseemissionsfromdigitalapparatussetoutinthe
RadioInterferenceRegulationsoftheCanadianDepartmentofCommunications.
Leprsentappareilnumriquenmetpasdebruitsradiolectriquesdpassantleslimitesapplicablesauxappareils
numriquesdelaclassAprescritesdansleRglementsurlebrouillageradiolectriquedictparleministredes
CommunicationsduCanada.
CLASS A ITE NOTICE
WARNING: ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhich
casetheusermayberequiredtotakeadequatemeasures.
CLASE A. AVISO DE ITE
ADVERTENCIA:EsteesunproductodeClaseA.Enunambientedomsticoesteproductopuedecausarinterferencia
deradioencuyocasopuedeserrequeridotomarmedidasadecuadas.
KLASSE A ITE ANMERKUNG
WARNHINWEIS:DiesesProduktzhltzurKlasseA(Industriebereich).InWohnbereichenkanneshierdurchzu
Funkstrungenkommen,dahersolltenangemesseneVorkehrungenzumSchutzgetroffenwerden.
PRODUCT SAFETY
Thisproductcomplieswiththefollowing:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950,IEC60950,EN 60825,
21 CFR1040.10.
SEGURIDAD DEL PRODUCTO
ElproductodeEnterasyscumpleconlosiguiente:UL60950,CSAC22.2No.60950,73/23/EEC,EN 60950,IEC 60950,
EN 60825,21 CFR1040.10.
PRODUKTSICHERHEIT
DiesesProduktentsprichtdenfolgendenRichtlinien:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950,
IEC 60950,EN60825,21CFR1040.10.
Downloaded from www.Manualslib.com manuals search engine
iii
ELECTROMAGNETIC COMPATIBILITY (EMC)
Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN6100032,
EN 6100033,EN55024,AS/NZSCISPR22,VCCIV3.
COMPATIBILIDAD ELECTROMGNETICA (EMC)
EsteproductodeEnterasyscumpleconlosiguiente:47CFRPartes2y15,CSAC108.8,89/336/EEC,EN55022,
EN 55024,EN6100032,EN6100033,AS/NZSCISPR22,VCCIV3.
ELEKTRO- MAGNETISCHE KOMPATIBILITT ( EMC )
DiesesProduktentsprichtdenfolgendenRichtlinien:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,
EN 6100032,EN6100033,EN55024,AS/NZSCISPR22,VCCIV3.
HAZARDOUS SUBSTANCES
ThisproductcomplieswiththerequirementsofEuropeanDirective,2002/95/EC,RestrictionofHazardousSubstances
(RoHS)inElectricalandElectronicEquipment.
EUROPEAN WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) NOTICE
InaccordancewithDirective2002/96/ECoftheEuropeanParliamentonwasteelectricalandelectronicequipment
(WEEE):
1. Thesymbolaboveindicatesthatseparatecollectionofelectricalandelectronicequipmentisrequiredandthatthis
productwasplacedontheEuropeanmarketafterAugust13,2005,thedateofenforcementforDirective
2002/96/EC.
2. Whenthisproducthasreachedtheendofitsserviceablelife,itcannotbedisposedofasunsortedmunicipalwaste.
Itmustbecollectedandtreatedseparately.
3. IthasbeendeterminedbytheEuropeanParliamentthattherearepotentialnegativeeffectsontheenvironment
andhumanhealthasaresultofthepresenceofhazardoussubstancesinelectricalandelectronicequipment.
4. ItistheusersresponsibilitytoutilizetheavailablecollectionsystemtoensureWEEEisproperlytreated.
Forinformationabouttheavailablecollectionsystem,pleasegotohttp://www.enterasys.com/services/support/or
contactEnterasysCustomerSupportat35361705586(Ireland).
Downloaded from www.Manualslib.com manuals search engine
iv
,|[
Supplement to Product Instructions
|||), (Hazardous Substance)
;(|
(Parts)
,
l|)
_
|_)
|
Cd)
|)
C
b
)
|/
lbb)
/
lbDl)
;
(Metal Parts)
` `
[||
(Circuit Modules)
` `
,
(Cables & Cable Assemblies)
` `
|{|;
(Plastic and Polymeric parts)
`
[;
(Circuit Breakers)
` `

,|||),;]||)|[|SJ/T 11363-2006 |^[|])
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
` ,|||)=,;[|)|[]SJ/T 11363-2006 |^[|]
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.

|[],,7,
|]]j[],["|)]:],[[|]|][;
This table shows where these substances may be found in the supply chain of Enterasys electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.

50
]'])|),,)][.
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.
|(,(|[|],]|,]],,['])|. ";
|]['])];,||)[),.
Downloaded from www.Manualslib.com manuals search engine
v
VCCI NOTICE
ThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformation
TechnologyEquipment(VCCI).Ifthisequipmentisusedinadomesticenvironment,radiodisturbancemayarise.
Whensuchtroubleoccurs,theusermayberequiredtotakecorrectiveactions.
BSMI EMC STATEMENT TAIWAN
ThisisaclassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasetheuser
mayberequiredtotakeadequatemeasures.
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
SINGLE MODE NETWORK EXPANSION MODULES USE CLASS 1 LASER TRANSCEIVERS.
READ THE FOLLOWING SAFETY INFORMATION
BEFORE INSTALLING OR OPERATING THESE MODULES.
TheClass1lasertransceiversuseanopticalfeedbacklooptomaintainClass1operationlimits.Thiscontrolloop
eliminatestheneedformaintenancechecksoradjustments.Theoutputisfactoryset,anddoesnotallowanyuser
adjustment.Class1Lasertransceiverscomplywiththefollowingsafetystandards:
21CFR1040.10and1040.11U.S.DepartmentofHealthandHumanServices(FDA).
IECPublication825(InternationalElectrotechnicalCommission).
CENELECEN60825(EuropeanCommitteeforElectrotechnicalStandardization).
Whenoperatingwithintheirperformancelimitations,lasertransceiveroutputmeetstheClass1accessibleemission
limitofallthreestandards.Class1levelsoflaserradiationarenotconsideredhazardous.
Whentheconnectorisinplace,alllaserradiationremainswithinthefiber.Themaximumamountofradiantpower
exitingthefiber(undernormalconditions)is12.6dBmor55x10
6
watts.
Removingtheopticalconnectorfromthetransceiverallowslaserradiationtoemitdirectlyfromtheopticalport.The
maximumradiancefromtheopticalport(underworstcaseconditions)is0.8Wcm
2
or8x10
3
Wm
2
sr1.
Donotuseopticalinstrumentstoviewthelaseroutput.Theuseofopticalinstrumentstoviewlaseroutput
increaseseyehazard.Whenviewingtheoutputopticalport,powermustberemovedfromthenetworkadapter.
Downloaded from www.Manualslib.com manuals search engine
vi
DECLARATION OF CONFORMITY
ApplicationofCouncilDirective(s): 89/336/EEC
73/23/EEC
ManufacturersName: Enterasys Networks, Inc.
ManufacturersAddress: 50MinutemanRoad
Andover,MA01810
USA
EuropeanRepresentativeAddress: Enterasys Networks,Ltd.
NexusHouse,NewburyBusinessPark
LondonRoad,Newbury
BerkshireRG142PZ,England
ConformancetoDirective(s)/ProductStandards: ECDirective89/336/EEC
EN55022
EN6100032
EN6100033
EN55024
ECDirective73/23/EEC
EN60950
EN60825
EquipmentType/Environment: NetworkingEquipment,foruseinaCommercial
orLightIndustrialEnvironment.
Enterasys Networks, Inc.declaresthattheequipmentpackagedwiththisnoticeconformstotheabovedirectives.
Downloaded from www.Manualslib.com manuals search engine
vii
ENTERASYS NETWORKS, INC.
FIRMWARE LICENSE AGREEMENT
BEFOREOPENINGORUTILIZINGTHEENCLOSEDPRODUCT,
CAREFULLYREADTHISLICENSEAGREEMENT.
Thisdocumentisanagreement(Agreement)betweentheenduser(You)andEnterasys Networks, Inc.onbehalf
ofitselfanditsAffiliates(ashereinafterdefined)(Enterasys)thatsetsforthYourrightsandobligationswithrespect
totheEnterasyssoftwareprogram/firmwareinstalledontheEnterasysproduct(includinganyaccompanying
documentation,hardwareormedia)(Program)inthepackageandprevailsoveranyadditional,conflictingor
inconsistenttermsandconditionsappearingonanypurchaseorderorotherdocumentsubmittedbyYou.Affiliate
meansanyperson,partnership,corporation,limitedliabilitycompany,orotherformofenterprisethatdirectlyor
indirectlythroughoneormoreintermediaries,controls,oriscontrolledby,orisundercommoncontrolwiththeparty
specified.ThisAgreementconstitutestheentireunderstandingbetweentheparties,andsupersedesallprior
discussions,representations,understandingsoragreements,whetheroralorinwriting,betweenthepartieswith
respecttothesubjectmatterofthisAgreement.TheProgrammaybecontainedinfirmware,chipsorothermedia.
BYINSTALLINGOROTHERWISEUSINGTHEPROGRAM,YOUREPRESENTTHATYOUAREAUTHORIZEDTO
ACCEPTTHESETERMSONBEHALFOFTHEENDUSER(IFTHEENDUSERISANENTITYONWHOSEBEHALF
YOUAREAUTHORIZEDTOACT,YOUANDYOURSHALLBEDEEMEDTOREFERTOSUCHENTITY)AND
THATYOUAGREETHATYOUAREBOUNDBYTHETERMSOFTHISAGREEMENT,WHICHINCLUDES,
AMONGOTHERPROVISIONS,THELICENSE,THEDISCLAIMEROFWARRANTYANDTHELIMITATIONOF
LIABILITY.IFYOUDONOTAGREETOTHETERMSOFTHISAGREEMENTORARENOTAUTHORIZEDTO
ENTERINTOTHISAGREEMENT,ENTERASYSISUNWILLINGTOLICENSETHEPROGRAMTOYOUANDYOU
AGREETORETURNTHEUNOPENEDPRODUCTTOENTERASYSORYOURDEALER,IFANY,WITHINTEN
(10)DAYSFOLLOWINGTHEDATEOFRECEIPTFORAFULLREFUND.
IFYOUHAVEANYQUESTIONSABOUTTHISAGREEMENT,CONTACTENTERASYS NETWORKS,LEGAL
DEPARTMENTAT(978)6841000.
YouandEnterasysagreeasfollows:
1. LICENSE. Youhavethenonexclusiveandnontransferablerighttouseonlytheone(1)copyoftheProgram
providedinthispackagesubjecttothetermsandconditionsofthisAgreement.
2. RESTRICTIONS. ExceptasotherwiseauthorizedinwritingbyEnterasys,Youmaynot,normayYoupermitany
thirdpartyto:
(i) Reverseengineer,decompile,disassembleormodifytheProgram,inwholeorinpart,includingforreasons
oferrorcorrectionorinteroperability,excepttotheextentexpresslypermittedbyapplicablelawandtothe
extentthepartiesshallnotbepermittedbythatapplicablelaw,suchrightsareexpresslyexcluded.
InformationnecessarytoachieveinteroperabilityorcorrecterrorsisavailablefromEnterasysuponrequest
anduponpaymentofEnterasysapplicablefee.
(ii) IncorporatetheProgram,inwholeorinpart,inanyotherproductorcreatederivativeworksbasedonthe
Program,inwholeorinpart.
(iii) Publish,disclose,copy,reproduceortransmittheProgram,inwholeorinpart.
(iv) Assign,sell,license,sublicense,rent,lease,encumberbywayofsecurityinterest,pledgeorotherwisetransfer
theProgram,inwholeorinpart.
(v) Removeanycopyright,trademark,proprietaryrights,disclaimerorwarningnoticeincludedonorembedded
inanypartoftheProgram.
Downloaded from www.Manualslib.com manuals search engine
viii
3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateand
federalcourtsoftheCommonwealthofMassachusettswithoutregardtoitsconflictsoflawsprovisions.Youacceptthe
personaljurisdictionandvenueoftheCommonwealthofMassachusettscourts.Noneofthe1980UnitedNations
ConventiononContractsfortheInternationalSaleofGoods,theUnitedNationsConventionontheLimitationPeriod
intheInternationalSaleofGoods,andtheUniformComputerInformationTransactionsActshallapplytothis
Agreement.
4. EXPORTRESTRICTIONS. YouunderstandthatEnterasysanditsAffiliatesaresubjecttoregulationbyagencies
oftheU.S.Government,includingtheU.S.DepartmentofCommerce,whichprohibitexportordiversionofcertain
technicalproductstocertaincountries,unlessalicensetoexporttheProgramisobtainedfromtheU.S.Governmentor
anexceptionfromobtainingsuchlicensemayberelieduponbytheexportingparty.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionCIVundertheU.S.Export
AdministrationRegulations,YouagreethatYouareacivilenduseroftheProgramandagreethatYouwillusethe
Programforcivilendusesonlyandnotformilitarypurposes.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionTSRundertheU.S.Export
AdministrationRegulations,inadditiontotherestrictionontransfersetforthinSections1or2ofthisAgreement,You
agreenotto(i)reexportorreleasetheProgram,thesourcecodefortheProgramortechnologytoanationalofacountry
inCountryGroupsD:1orE:2(Albania,Armenia,Azerbaijan,Belarus,Bulgaria,Cambodia,Cuba,Estonia,Georgia,
Iraq,Kazakhstan,Kyrgyzstan,Laos,Latvia,Libya,Lithuania,Moldova,NorthKorea,thePeoplesRepublicofChina,
Romania,Russia,Rwanda,Tajikistan,Turkmenistan,Ukraine,Uzbekistan,Vietnam,orsuchothercountriesasmaybe
designatedbytheUnitedStatesGovernment),(ii)exporttoCountryGroupsD:1orE:2(asdefinedherein)thedirect
productoftheProgramorthetechnology,ifsuchforeignproduceddirectproductissubjecttonationalsecurity
controlsasidentifiedontheU.S.CommerceControlList,or(iii)ifthedirectproductofthetechnologyisacomplete
plantoranymajorcomponentofaplant,exporttoCountryGroupsD:1orE:2thedirectproductoftheplantoramajor
componentthereof,ifsuchforeignproduceddirectproductissubjecttonationalsecuritycontrolsasidentifiedonthe
U.S.CommerceControlListorissubjecttoStateDepartmentcontrolsundertheU.S.MunitionsList.
5. UNITEDSTATESGOVERNMENTRESTRICTEDRIGHTS. TheenclosedProgram(i)wasdevelopedsolelyat
privateexpense;(ii)containsrestrictedcomputersoftwaresubmittedwithrestrictedrightsinaccordancewithsection
52.22719(a)through(d)oftheCommercialComputerSoftwareRestrictedRightsClauseanditssuccessors,and(iii)in
allrespectsisproprietarydatabelongingtoEnterasysand/oritssuppliers.ForDepartmentofDefenseunits,the
ProgramisconsideredcommercialcomputersoftwareinaccordancewithDFARSsection227.72023anditssuccessors,
anduse,duplication,ordisclosurebytheGovernmentissubjecttorestrictionssetforthherein.
6. DISCLAIMEROFWARRANTY. EXCEPTFORTHOSEWARRANTIESEXPRESSLYPROVIDEDTOYOUIN
WRITINGBYENTERASYS,ENTERASYSDISCLAIMSALLWARRANTIES,EITHEREXPRESSORIMPLIED,
INCLUDINGBUTNOTLIMITEDTOIMPLIEDWARRANTIESOFMERCHANTABILITY,SATISFACTORY
QUALITY,FITNESSFORAPARTICULARPURPOSE,TITLEANDNONINFRINGEMENTWITHRESPECTTOTHE
PROGRAM.IFIMPLIEDWARRANTIESMAYNOTBEDISCLAIMEDBYAPPLICABLELAW,THENANYIMPLIED
WARRANTIESARELIMITEDINDURATIONTOTHIRTY(30)DAYSAFTERDELIVERYOFTHEPROGRAMTO
YOU.
7. LIMITATIONOFLIABILITY. INNOEVENTSHALLENTERASYSORITSSUPPLIERSBELIABLEFORANY
DAMAGESWHATSOEVER(INCLUDING,WITHOUTLIMITATION,DAMAGESFORLOSSOFBUSINESS,
PROFITS,BUSINESSINTERRUPTION,LOSSOFBUSINESSINFORMATION,SPECIAL,INCIDENTAL,
CONSEQUENTIAL,ORRELIANCEDAMAGES,OROTHERLOSS)ARISINGOUTOFTHEUSEORINABILITYTO
USETHEPROGRAM,EVENIFENTERASYSHASBEENADVISEDOFTHEPOSSIBILITYOFSUCHDAMAGES.
THISFOREGOINGLIMITATIONSHALLAPPLYREGARDLESSOFTHECAUSEOFACTIONUNDERWHICH
DAMAGESARESOUGHT.
THECUMULATIVELIABILITYOFENTERASYSTOYOUFORALLCLAIMSRELATINGTOTHEPROGRAM,
INCONTRACT,TORTOROTHERWISE,SHALLNOTEXCEEDTHETOTALAMOUNTOFFEESPAIDTO
ENTERASYSBYYOUFORTHERIGHTSGRANTEDHEREIN.
Downloaded from www.Manualslib.com manuals search engine
ix
8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramare
ofcriticalvaluetoEnterasysand,accordingly,Youherebyagreeto maintaincompletebooks,recordsandaccounts
showing(i)licensefeesdueandpaid,and(ii)theuse,copyinganddeploymentoftheProgram.Youalsograntto
Enterasysanditsauthorizedrepresentatives,uponreasonablenotice,therightto auditandexamineduringYour
normalbusinesshours,Yourbooks,records,accountsandhardwaredevicesuponwhichtheProgrammaybedeployed
toverifycompliancewiththisAgreement,includingtheverificationofthelicensefeesdueandpaidEnterasysandthe
use,copyinganddeploymentoftheProgram.Enterasysrightofexamination shallbeexercisedreasonably,ingood
faithandinamannercalculatedtonotunreasonablyinterferewithYourbusiness.Intheeventsuchauditdiscovers
noncompliancewiththisAgreement,includingcopiesoftheProgrammade,usedordeployedinbreachofthis
Agreement,YoushallpromptlypaytoEnterasystheappropriatelicensefees.Enterasys reservestheright,tobe
exercisedinitssolediscretionandwithoutpriornotice,toterminatethislicense,effectiveimmediately,forfailureto
complywiththisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramandshall
returntoEnterasystheProgramandallcopiesoftheProgram.
9. OWNERSHIP. Thisisalicenseagreementandnotanagreementforsale.Youacknowledgeandagreethatthe
Programconstitutestradesecretsand/orcopyrightedmaterialofEnterasysand/oritssuppliers.Youagreeto
implementreasonablesecuritymeasurestoprotectsuchtradesecretsandcopyrightedmaterial.Allright,titleand
interestinandtotheProgramshallremainwithEnterasysand/oritssuppliers.Allrightsnotspecificallygrantedto
YoushallbereservedtoEnterasys.
10. ENFORCEMENT. YouacknowledgeandagreethatanybreachofSections2,4,or9ofthisAgreementbyYoumay
causeEnterasysirreparabledamageforwhichrecoveryofmoneydamageswouldbeinadequate,andthatEnterasys
maybeentitledtoseektimelyinjunctiverelieftoprotectEnterasysrightsunderthisAgreementinadditiontoanyand
allremediesavailableatlaw.
11. ASSIGNMENT. Youmaynotassign,transferorsublicensethisAgreementoranyofYourrightsorobligations
underthisAgreement,exceptthatYoumayassignthisAgreementtoanypersonorentitywhichacquiressubstantially
allofYourstockorassets.EnterasysmayassignthisAgreementinitssolediscretion.ThisAgreementshallbebinding
uponandinuretothebenefitoftheparties,theirlegalrepresentatives,permittedtransferees,successorsandassignsas
permittedbythisAgreement.Anyattemptedassignment,transferorsublicenseinviolationofthetermsofthis
AgreementshallbevoidandabreachofthisAgreement.
12. WAIVER. AwaiverbyEnterasysofabreachofanyofthetermsandconditionsofthisAgreementmustbein
writingandwillnotbeconstruedasawaiverofanysubsequentbreachofsuchtermorcondition.Enterasysfailureto
enforceatermuponYourbreachofsuchtermshallnotbeconstruedasawaiverofYourbreachorpreventenforcement
onanyotheroccasion.
13. SEVERABILITY. IntheeventanyprovisionofthisAgreementisfoundtobeinvalid,illegalorunenforceable,the
validity,legalityandenforceabilityofanyoftheremainingprovisionsshallnotinanywaybeaffectedorimpaired
thereby,andthatprovisionshallbereformed,construedandenforcedtothemaximumextentpermissible.Anysuch
invalidity,illegalityorunenforceabilityinanyjurisdictionshallnotinvalidateorrenderillegalorunenforceablesuch
provisioninanyotherjurisdiction.
14. TERMINATION. EnterasysmayterminatethisAgreementimmediatelyuponYourbreachofanyoftheterms
andconditionsofthisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramand
shallreturntoEnterasystheProgramandallcopiesoftheProgram.
Downloaded from www.Manualslib.com manuals search engine
x
Downloaded from www.Manualslib.com manuals search engine
xi
Contents
About This Guide
Who Should Use This Guide ............................................................................................................... xv
Related Documents ........................................................................................................................... xvi
Conventions Used in This Guide .......................................................................................................xvii
Getting Help ...................................................................................................................................... xviii
Chapter 1: Introduction
Overview of DFE-Platinum Module Capabilities ................................................................................1-1
DFE-Platinum Modules ......................................................................................................................1-2
Connectivity .......................................................................................................................................1-4
Management ......................................................................................................................................1-4
Switch Configuration Using WebView .........................................................................................1-4
Switch Configuration Using CLI Commands ...............................................................................1-4
Secure Networks Policy Support .......................................................................................................1-5
Standards Compatibility .....................................................................................................................1-5
LANVIEW Diagnostic LEDs ...............................................................................................................1-5
Chapter 2: Network Requirements
Link Aggregation ................................................................................................................................2-1
Module Placement in a Matrix E7 Chassis ........................................................................................2-2
10BASE-T Network ............................................................................................................................2-2
100BASE-TX Network .......................................................................................................................2-2
1000BASE-T Network ........................................................................................................................2-2
Chapter 3: Installation
Unpacking the DFE-Platinum Module ................................................................................................3-2
Installing Optional Network Expansion Module (NEM) ......................................................................3-2
Backplane Connections and Installation Rules ..................................................................................3-3
FTM1 and FTM2 Connectivity .....................................................................................................3-3
Module Placement and Rules ......................................................................................................3-3
Installing Module into Matrix E7 or Matrix N7 Chassis .......................................................................3-6
Preparation ..................................................................................................................................3-6
Installing Module into Matrix N3, N5, or N1 Chassis ..........................................................................3-9
Connecting to the Network ...............................................................................................................3-11
Connecting UTP Cables to 7G4202-60 or 7G4282-41 ..............................................................3-11
Connecting to COM Port for Local Management .............................................................................3-15
What Is Needed .........................................................................................................................3-15
Connecting to an IBM PC or Compatible Device .......................................................................3-15
Connecting to a VT Series Terminal ..........................................................................................3-17
Connecting to a Modem ............................................................................................................3-18
Adapter Wiring and Signal Assignments ...................................................................................3-20
Downloaded from www.Manualslib.com manuals search engine
xii
Completing the Installation ...............................................................................................................3-21
Completing the Installation of a New System ............................................................................3-21
Completing the Installation of a DFE-Platinum Module in an Existing System ..........................3-23
Chapter 4: Troubleshooting
Using LANVIEW .................................................................................................................................4-1
Troubleshooting Checklist ..................................................................................................................4-5
Overview of DFE-Platinum Module Shutdown Procedure .................................................................4-6
Recommended Shutdown Procedure Using OFFLINE/RESET Switch .......................................4-7
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch .............................................4-8
Appendix A: Specifications
DFE-Platinum Module Specifications ................................................................................................ A-1
COM Port Pinout Assignments ......................................................................................................... A-2
Regulatory Compliance ..................................................................................................................... A-3
Appendix B: Mode Switch Bank Settings and Optional Installations
Required Tools .................................................................................................................................. B-1
Setting the Mode Switches ............................................................................................................... B-1
Memory Locations and Replacement Procedures ............................................................................ B-3
DIMM Replacement Procedure (7G4282-41 only) ..................................................................... B-4
DRAM SIMM Replacement Procedure for 7G4202-60 and 7G4282-41 ..................................... B-7
Index
Figures
1-1 7G4202-60 and 7G4282-41 DFE-Platinum Modules .............................................................1-3
3-2 Examples, Module Placement in Matrix E7 Chassis..............................................................3-4
3-3 Installing Module into Matrix E7 or Matrix N7 Chassis (E7 shown)........................................3-8
3-4 Installing Module into Matrix N3, N5, or N1 Chassis (N3 shown) ........................................3-10
3-5 Connecting a Twisted Pair Segment to the DFE-Platinum Module......................................3-12
3-6 Crossover Four-Wire Cable RJ45 Pinouts, Connections Between Hub Devices.................3-13
3-7 Straight-Through Four-Wire Cable RJ45 Pinouts, Connections
Between Switches and End User Devices...........................................................................3-13
3-8 Eight-Wire Crossover Cable RJ45 Pinouts, Connections Between Hub Devices................3-14
3-9 Eight-Wire Straight-Through Cable RJ45 Pinouts, Connections
Between Switches and End User Devices...........................................................................3-14
3-10 Connecting an IBM PC or Compatible .................................................................................3-16
3-11 Connecting a VT Series Terminal ........................................................................................3-18
3-12 Connecting to a Modem.......................................................................................................3-19
3-13 Matrix DFE Startup Screen Example (N7 Chassis) .............................................................3-23
4-1 LANVIEW LEDs .....................................................................................................................4-2
4-14 OFFLINE/RESET Switch .......................................................................................................4-7
Downloaded from www.Manualslib.com manuals search engine
xiii
B-1 Mode Switch Location on 7G4202-60 and 7G4282-41......................................................... B-2
B-2 Memory Module Locations on the 7G4202-60...................................................................... B-3
B-3 Memory Module Locations on the 7G4282-41...................................................................... B-4
B-4 NEM Removal and DIMM Connector Location on 7G4282-41 ............................................. B-5
B-5 Removing the Existing DIMM from 7G4282-41..................................................................... B-5
B-6 Installing the DIMM on 7G4282-41 ....................................................................................... B-6
B-7 Removing Existing DRAM SIMM from 7G4202-60 or 7G4282-41........................................ B-7
B-8 Installing the DRAM SIMM on 7G4202-60 or 7G4282-41..................................................... B-8
Tables
3-1 Contents of DFE-Platinum Module Carton ...................................................................................3-2
4-2 LANVIEW LEDs............................................................................................................................4-3
4-3 Troubleshooting Checklist ............................................................................................................4-5
A-1 Specifications .............................................................................................................................. A-1
A-2 COM Port Pin Assignments......................................................................................................... A-2
A-3 Compliance Standards ................................................................................................................ A-3
Downloaded from www.Manualslib.com manuals search engine
xiv
Downloaded from www.Manualslib.com manuals search engine
xv
About This Guide
This guide provides an overview, installation and troubleshooting instructions, and
specifications for the Enterasys Matrix DFE-Platinum 7G4202-60 and
7G4282-41 modules.
For information about the CLI (Command Line Interface) set of commands used to
configure and manage the DFE-Platinum modules, refer to the Enterasys Matrix
DFE-Platinum Series Configuration Guide.
Who Should Use This Guide
This guide is intended for a network administrator responsible for installing and
setting up the DFE-Platinum modules.
Note: In this guide, the following terms are used:
DFE refers to Distributed Forwarding Engine series of modules.
DFE-Platinum module or module refers to the 7G4282-41 and 7G4202-60. If the
information applies to only one of the modules, the module is referred to by its model
number (such as 7G4282-41).
Network expansion module (NEM) refers to an optional uplink card installed on the
main logic board and accessible through the option slot of the 7G4282-41.
Important Notice
Depending on the firmware version used in the DFE-Platinum module, some features
described in this document may not be supported. Refer to the Release Notes shipped
with the DFE-Platinum module to determine which features are supported.
Electrical Hazard: Only qualified personnel should perform installation
procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos
de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes
und qualifiziertes Personal vorgenommen werden.
Downloaded from www.Manualslib.com manuals search engine
xvi
HOW TO USE THIS GUIDE
ThisprefaceprovidesanoverviewofthisguideandtheDFEPlatinumSeriesmanualset,
andabriefsummaryofeachchapter;definestheconventionsusedinthisdocument;and
instructshowtoobtaintechnicalsupportfromEnterasys Networks.Tolocateinformation
aboutvarioussubjectsinthisguide,refertothefollowingtable:
Related Documents
The manuals listed below can be obtained from the World Wide Web in Adobe
Acrobat Portable Document Format (PDF) at the following site:
http://www.enterasys.com/support/manuals
EnterasysMatrixDFEPlatinumSeriesConfigurationGuideprovidesinformationon
howtousetheCommandLineInterfacetosetupandmanagetheDFEPlatinum
modules.
CablingGuideprovidesinformationondBlossandcablespecifications.
UnliketheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide,theCablingGuide
isnotlistedalphabeticallyonthewebsite.Instead,itislistedundertheOverview
Guideslink.
For... Refer to...
An overview of the DFE-Platinum modules Chapter 1, Introduction
Network requirements that must be met before
installing the DFE-Platinum modules
Chapter 2, Network Requirements
Instructions to install the DFE-Platinum module
hardware
Chapter 3, Installation
Troubleshooting installation problems and
diagnosing network/operational problems using
the LANVIEW LEDs
Chapter 4, Troubleshooting
Specifications, environmental requirements, and
physical properties of the DFE-Platinum modules
Appendix A, Specifications
Instructions to set the mode switches when
necessary and remove and replace DRAM SIMM
and DIMM memory
Appendix B, Mode Switch Bank Settings
and Optional Installations
Downloaded from www.Manualslib.com manuals search engine
xvii
Conventions Used in This Guide
The following conventions are used in this guide:
Lowercase x: Indicates the general use of an alphanumeric character (e.g., 6x1xx, the xs
indicate a combination of numbers or letters).
Note: Calls the readers attention to any item of information that may be of
special importance.
Caution: Contains information essential to avoid damage to the equipment.
Precaucin: Contiene informacin esencial para prevenir daar el equipo.
Achtung: Verweit auf wichtige Informationen zum Schutz gegen
Beschdigungen.
Electrical Hazard: Warns against an action that could result in personal injury
or death due to an electrical hazard.
Riesgo Electrico: Advierte contra una accin que pudiera resultar en lesin
corporal o la muerte debido a un riesgo elctrico.
Elektrischer Gefahrenhinweis: Warnung vor smtlichen Handlungen, die zu
Verletzung von Personen oder Todesfllen hervorgerufen durch elektrische
Spannung fhren knnen!
Downloaded from www.Manualslib.com manuals search engine
xviii
Getting Help
For additional support related to the modules or this document, contact
Enterasys Networks using one of the following methods:
Before contacting Enterasys Networks for technical support, have the following
information ready:
Your Enterasys Networks service contract number
A description of the failure
A description of any action(s) already taken to resolve the problem (for example,
changing mode switches, rebooting the unit)
The serial and revision numbers of all involved Enterasys Networks products in the
network
A description of your network environment (for example, layout and cable type)
Network load and frame size at the time of trouble (if known)
The device history (for example, have you returned the device before, is this a recurring
problem)
Any previous Return Material Authorization (RMA) numbers
World Wide Web www.enterasys.com/services/support/
Phone 1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1000
For the Enterasys Networks Support toll-free number in your country:
www.enterasys.com/services/support/contact/
Internet mail support@enterasys.com
To expedite your message, type [SWITCHING] in the subject line.
To send comments concerning this document to the Technical Publications Department:
techpubs@enterasys.com
Please include the document Part Number in your email message.
Downloaded from www.Manualslib.com manuals search engine
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 1-1
1
Introduction
ThischapterprovidesanoverviewoftheDFEPlatinummodulecapabilities,and
introducesthe7G420260and7G428241DFEPlatinummodules.
OVERVIEW OF DFE-PLATINUM MODULE CAPABILITIES
ThePlatinumDistributedForwardingEngine(DFE)isEnterasys Networksnext
generationofenterprisemodulesfortheMatrixNSeriesandMatrixE7switches.These
DFEmodulesdeliverhighperformanceandflexibilitytoensurecomprehensive
switching,routing,QualityofService,security,andtrafficcontainment.Keyfeatures
include:
Superiorperformanceandcapacitytosupportmorehighbandwidthandlatency
sensitiveapplications
10/100/1000BaseTXand10GigabitEthernetconnectivity
IntegratedServicesDesignthatreducesthenumber/typeofmodulesrequired,
simplifiesnetworkdesign,andlowersentrycost
PortandUserBasedPolicyandMultilayerPacketClassificationthatprovides
granularcontrolandsecurityforbusinesscriticalapplications
Highavailabilityserviceswithstatefulfailoverforservicesandmanagement
Selflearningconfigurationmoduleswithincreasedreliabilityandfaulttolerancethat
reducesconfigurationtimeandmaximizesuptime
Networkwideconfiguration,change,andinventorymanagementthatiseasierto
install,troubleshoot,andmaintain
Reducedsupportandmaintenancecosts,anddecreasedconfigurationtime
SupportforavarietyofconvergedapplicationsincludingVoIPwithPowerover
Ethernet
Important Notice
Depending on the firmware version used in the DFE-Platinum module, some features described in
this document may not be supported. Refer to the Release Notes shipped with the DFE-Platinum
module to determine which features are supported.
Downloaded from www.Manualslib.com manuals search engine
DFE-Platinum Modules
1-2 Introduction
DFE-PLATINUM MODULES
ThissectionprovidesanoverviewofDFEPlatinummodules7G420260and7G428241
(Figure 11).
Eachofthefixedfrontpanelportscanoperateineitherhalfduplexorfullduplexmode
ofoperation.Theduplexmodecanbedeterminedbyeitherautonegotiationormanual
configuration.
TheDFEPlatinummoduleportscanbeconfiguredtocontroltrafficbylimitingtherateof
trafficacceptedintothemoduleandprioritizingtraffictoexpeditetheflowofhigher
prioritytrafficthroughthemodule.
TheDFEPlatinummodulereceivespowerandbackplaneconnectivitywhenitisinserted
intotheMatrix N1,Matrix N3,Matrix N5,Matrix N7,orMatrix E7chassis.
TheinformationconcerningtheDFEmodulefeaturesandhowtoconfigurethemtoa
networkareprovidedintheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide.
7G4202-60
The7G420260isanedgenetworkswitchwith60,10BASET/100BASETX/1000BASET
portsvia60frontpanelRJ45connectors.
7G4282-41
The7G428241isanedgenetworkswitchwith40,10BASET/100BASETX/1000BASET
compliantportsvia40fixedfrontpanelRJ45connectorsandaslotforanoptional
networkexpansionmodule(NEM).
Downloaded from www.Manualslib.com manuals search engine
DFE-Platinum Modules
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 1-3
Figure 1-1 7G4202-60 and 7G4282-41 DFE-Platinum Modules
OFFLINE/RESET switch GROUP selected LEDs
RJ45 COM (Console Port) GROUP status LEDs
CPU LED 7G4202-60 - Ports (41-60), 10/100/1000 Mbps, via 20 RJ45s
MGMT LED 7G4282-41 - NEM option slot
GROUP SELECT button Ports (1-40), 10/100/1000 Mbps, via 40 RJ45s
OFFLINE/
RESET
COM
MGMT CPU
GROUP
SELECT
GROUP
1
2
3
4
5
1
2
3
4
5
6
7
8
7X
G
R
O
U
P
1
1X
15X
G
R
O
U
P
2
9X
23X
G
R
O
U
P
3
17X
31X
G
R
O
U
P
4
25X
39X
G
R
O
U
P
5
33X
7G4282-41
Gb ENET
OFFLINE/
RESET
COM
MGMT CPU
3 2 1
GROUP
SELECT
GROUP
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20


7G4202-60
Gb ENET
DFE DFE
7G4282-41 7G4202-60
Downloaded from www.Manualslib.com manuals search engine
Connectivity
1-4 Introduction
Network Expansion Module (NEM) Option
The7G428241optionslotprovidesaccesstoaninstallednetworkexpansionmodule.
RefertotheEnterasys NetworkswebsiteforacurrentlistingoftheavailableNEMs.
SpecificinstallationinstructionsareshippedwitheachNEM.
CONNECTIVITY
7G4202-60
The7G420260has10BASET/100BASETX/1000BASETcompliantportsvia60,fixedRJ45
frontpanelconnectors.
7G4282-41
Dependingonhowthe7G428241(Figure 11)isconfigured,itcansupportupto:
40,10BASET/100BASETX/1000BASETswitchedportsconnectedthrough40,fixed
RJ45frontpanelconnectors,or
40,10BASET/100BASETX/1000BASETswitchedportsandanoptionalnetwork
expansionmodule.
MANAGEMENT
Managementofthemodulecanbeeitherinbandoroutofband.Inbandremote
managementispossibleusingTelnet,Enterasys NetworksNetSight

management
application,orWebViewapplication.Outofbandmanagementisprovidedthrough
theRJ45COM(Communication)portonthefrontpanelusingaVT100terminalora
VT100terminalemulator.
Switch Configuration Using WebView
Enterasys NetworksHTTPbasedWebmanagementapplication(WebView)isan
intuitivewebtoolforsimplemanagementtasks.
Switch Configuration Using CLI Commands
TheCLIcommandsenableyoutoperformmorecompleteswitchconfiguration
managementtasks.
ForCLIcommandsetinformationandhowtoconfigurethemodule,refertotheEnterasys
MatrixDFEPlatinumSeriesConfigurationGuide.
Downloaded from www.Manualslib.com manuals search engine
Secure Networks Policy Support
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 1-5
SECURE NETWORKS POLICY SUPPORT
PolicyEnabledNetworkingmanagestheallocationofnetworkinginfrastructure
resourcesinasecureandeffectivemanner.UsingSecureNetworksPolicy,anIT
AdministratorcanpredictablyassignappropriateresourcestotheUsers,Applications,
andServicesthatusethenetwork;whileblockingorcontainingaccessforinappropriate
orpotentiallydangerousnetworktraffic.Usingthistechnologyitispossible,forthefirst
time,toalignITserviceswiththeneedsofspecificusersandapplications,andtoleverage
thenetworkasakeycomponentoftheorganizationssecuritystrategy.
TheSecureNetworksPolicyArchitectureconsistsof3components:ClassificationRules,
NetworkServices,andBehavioralProfiles.Thesearedefinedasfollows:
ClassificationRulesdeterminehowspecifictrafficflows(identifiedbyLayer2,Layer
3,andLayer4informationinthedatapacket)aretreatedbyeachSwitchorRouter.In
general,ClassificationRulesareappliedtothenetworkinginfrastructureatthe
networkedge/ingresspoint.
NetworkServicesarelogicalgroupsofClassificationRulesthatidentifyspecific
networkedapplicationsorservices.Usersmaybepermittedordeniedaccesstothese
servicesbasedontheirrolewithintheorganization.Priorityandbandwidthrate
limitingmayalsobecontrolledusingNetworkServices.
BehavioralProfiles(orroles)areusedtoassignNetworkServicestogroupsofusers
whosharecommonneedsforexampleExecutiveManagers,HumanResources
Personnel,orGuestUsers.Access,resources,andsecurityrestrictionsareappliedas
appropriatetoeachBehavioralProfile.Avarietyofauthenticationmethodsincluding
802.1X,EAPTLS,EAPTTLS,andPEAPmaybeusedtoclassifyandauthorizeeach
individualuser;andtheITAdministratormayalsodefineaBehavioralProfileto
applyintheabsenceofanauthenticationframework.
STANDARDS COMPATIBILITY
TheDFEPlatinummodulesarefullycompliantwiththeIEEE802.32002,802.3ae2002,
802.1D1998,and802.1Q1998standards.TheDFEPlatinummoduleprovidesIEEE
802.1D1998SpanningTreeAlgorithm(STA)supporttoenhancetheoverallreliabilityof
thenetworkandprotectagainstloopconditions.
LANVIEW DIAGNOSTIC LEDs
LANVIEWdiagnosticLEDsserveasanimportanttroubleshootingaidbyprovidingan
easywaytoobservethestatusofindividualportsandoverallnetworkoperations.
Downloaded from www.Manualslib.com manuals search engine
LANVIEW Diagnostic LEDs
1-6 Introduction
Downloaded from www.Manualslib.com manuals search engine
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 2-1
2
Network Requirements
Beforeinstallingthemodule,reviewtherequirementsandspecificationsreferredtoin
thischapterconcerningthefollowing:
LinkAggregationonpage 21
ModulePlacementinaMatrixE7Chassisonpage 22
10BASETNetworkonpage 22
100BASETXNetworkonpage 22
1000BASETNetworkonpage 22
1000BASETNetworkonpage 22
Thenetworkinstallationmustmeettherequirementstoensuresatisfactoryperformance
ofthisequipment.Failuretodosowillproducepoornetworkperformance.
LINK AGGREGATION
LinkAggregationisamethodofgroupingmultiplephysicalportsonanetworkdevice
intoonelogicallinkaccordingtotheIEEE802.3ad2002standard.BecauseLink
Aggregationisstandardsbased,itallowsforautomaticconfigurationwithmanual
overrides(ifapplicable),andcanoperateon10Mbps,100Mbps,or1000MbpsEthernet
fullduplexports.Thusthenetworkadministratorcancombineagroupoffive100Mbps
portsintoalogicallink(trunk)thatfunctionsasasingle500Mbpsport.Aslongasthe
modulesagreeonwhichportsareinthetrunk,therearenoproblemswithlooping,and
theSpanningTreecantreatthistrunkasasingleport.
Innormalusage(andtypicalimplementations)thereisnoneedtoenable/disableportsfor
LinkAggregation.Thedefaultvalueswillresultinthemaximumnumberofaggregations
possible.Iftheswitchisplacedinaconfigurationwithitspeersnotrunningtheprotocol,
noaggregationswillbeformedandthemoduleswillfunctionnormally(thatis,Spanning
Treewillblockredundantpaths).
Note: The Enterasys Matrix DFE-Platinum Series Configuration Guide and the Cabling
Guide referred to in the following sections can be found on the Enterasys Networks World
Wide Web site: http://www.enterasys.com/support/manuals
Refer to Related Documents in About This Guide.
Downloaded from www.Manualslib.com manuals search engine
Module Placement in a Matrix E7 Chassis
2-2 Network Requirements
FordetailsaboutthecommandsinvolvedwithconfiguringtheLinkAggregation
function,refertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide.
MODULE PLACEMENT IN A MATRIX E7 CHASSIS
Ifyouwanttomix6x1xxx,6x2xxx,6x3xxx,and7H43xxxxseriesmodulesinthesame
Matrix E7chassis,andsuccessfullybridgedatatraffictosomeorallmodulesinthe
chassis,itisnecessarytohaveabridgingmodule(suchasthe7H438549)installed,andto
followthemoduleplacementrulesdescribedinBackplaneConnectionsandInstallation
Rulesonpage 33.
10BASE-T NETWORK
Whenconnectinga10BASETsegmenttoanyofthefixedfrontpanelportsofthe7G4202
60or7G428241,ensurethatthenetworkmeetstheEthernetnetworkrequirementsofthe
IEEE802.32002standardfor10BASET.RefertotheCablingGuidefordetails.
100BASE-TX NETWORK
Thefixedfrontpanelportsofthe7G420260or7G428241provideaconnectionthat
supportsCategory5UTPcabling.Thedeviceattheotherendofthetwistedpairsegment
mustmeetIEEE802.32002100BASETXFastEthernetnetworkrequirementsforthe
devicestooperateat100 Mbps.RefertotheCablingGuidefordetails.
1000BASE-T NETWORK
The7G428241and 7G420260 support10/100/1000 MbpsviafixedRJ45frontpanel
connectors.Theseconnectionssupportcopperwireconnectionsthatcanoperateupto
1000 Mbps.ThedeviceattheotherendofthetwistedpairsegmentmustmeetIEEE
802.32002networkrequirementsforthedevicestooperateatGigabitspeed.
Note: If a port is to operate at 100 Mbps, Category 5 cabling must be used. Category 3
cabling does not meet 100 Mbps specifications. For 10 Mbps operation only, Category 3
or Category 5 cabling can be used. Refer to 100BASE-TX Network on page 2-2 for
information about 100BASE-TX networks and cabling.
Note: The fixed ports of the module support Category 5 UTP cabling with an impedance
between 85 and 111 ohms for 100 Mbps operation. The module is capable of operating at
10, 100, or 1000 Mbps and can automatically sense the port speed of the other device and
adjust its speed accordingly.
Note: The fixed ports of each module support Category 5 UTP cabling with an impedance
between 85 and 111 ohms for 100 and 1000 Mbps operation and can automatically sense
the port speed of the other device and adjusts its speed accordingly.
Downloaded from www.Manualslib.com manuals search engine
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-1
3
Installation
Thischapterprovidestheinstructionstoinstallthe7G420260and7G428241
DFEPlatinummodules.
Followtheorderofthesectionslistedbelowtocorrectlyinstallthemodules.
UnpackingtheDFEPlatinumModuleonpage 32
InstallingOptionalNetworkExpansionModule(NEM)onpage 32
BackplaneConnectionsandInstallationRulesonpage 33
InstallingModuleintoMatrix E7orMatrix N7Chassisonpage 36
InstallingModuleintoMatrixN3,N5,orN1Chassisonpage 39
ConnectingtotheNetworkonpage 311
ConnectingtoCOMPortforLocalManagementonpage 315
CompletingtheInstallationonpage 321
Electrical Hazard: Only qualified personnel should install the DFE-Platinum modules.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de
instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und
qualifiziertes Personal vorgenommen werden.
Important Notice
Read the Release Notes shipped with the DFE-Platinum module to check for any exceptions to the
supported features and operation documented in this guide.
Note: Unless otherwise noted, the installation instructions apply to all DFE-Platinum
modules.
Downloaded from www.Manualslib.com manuals search engine
Unpacking the DFE-Platinum Module
3-2 Installation
UNPACKING THE DFE-PLATINUM MODULE
UnpacktheDFEPlatinummoduleasfollows:
1. OpentheboxandremovethepackingmaterialprotectingtheDFEPlatinummodule.
2. VerifythecontentsofthecartonaslistedinTable 31.
3. RemovethetapesealonthenonconductivebagtoremovetheDFEPlatinum
module.
4. PerformavisualinspectionoftheDFEPlatinummoduleforanysignsofphysical
damage.ContactEnterasysNetworksifthereareanysignsofdamage.Referto
GettingHelponpage xviiifordetails.
INSTALLING OPTIONAL NETWORK EXPANSION MODULE (NEM)
RefertoyourreleasenotesortotheEnterasys Networkswebsiteforthelatestavailable
networkexpansionmodules.
APhillipsscrewdriverisneededtoinstallanoptionalNEMintothe7G428241.
InstallingaNEMinvolves
removingthecoverplatefromtheDFEPlatinummodule,and
attachingtheNEMtotheDFEPlatinummodule.
RefertotheinstallationinstructionsshippedwiththeNEMfordetails.
Table 3-1 Contents of DFE-Platinum Module Carton
Item Quantity
DFE-Platinum module (7G4202-60or7G4282-41) 1
Installation Guide 1
Customer Release Notes 1
Note: Install any optional equipment before proceeding to Backplane Connections and
Installation Rules on page 3-3 for an explanation of the rules to install different series
modules in a Matrix E7 chassis.
Downloaded from www.Manualslib.com manuals search engine
Backplane Connections and Installation Rules
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-3
BACKPLANE CONNECTIONS AND INSTALLATION RULES
ThefollowingsectionsdescribetheFTM1andFTM2backplaneconnections,andthe
hardwareconfigurationruleswheninstallingfirst(6x1xx),second(6x2xx),andthird
(6x3xx)generationmodules,andDFEPlatinummodules(7xxxxx)intothesame
Matrix E7chassis.
FTM1 and FTM2 Connectivity
TheMatrix E7(6C107)chassishasbackplanesreferredtoasFTM1andFTM2.The7xxxxx
DFEPlatinummodulesuseFTM2forhighspeedcommunicationtoeachotherand
operateasoneswitchingunitwithasingleIPaddress.Thetrafficthroughthesemodules
doesnotconnecttoFTM1exceptthroughanFTMbridgingmodulesuchasthe
DFEPlatinum7H438225,7H438249,7H438349,or7H438549.InstallationGuidesfor
thesebridgingmodulesarelocatedontheEnterasysNetworksWorldWideWebsite:
http://www.enterasys.com/support/manuals.
TheFTMbridgingmoduleshaveconnectionstobothFTM1andFTM2backplanes,which
enablesthemtoswitchframesbetweenthetwobackplanesandallmodulesinthe6C107
chassis.However,theolderfirst(6x1xx),second(6x2xx),andthird(6x3xx)generation
modulesarestillmanagedusingtheirownLocalManagementandarenotsubjectto
managementbytheDFEPlatinummodulemanagemententity.
TheMatrixN1(7C111),MatrixN3(7C103),Matrix N5(7C105P),andMatrixN7(7C107)
chassishaveonlyFTM2connectionsandsupportonlyDFEmodules.
Module Placement and Rules
TheDFEmodulescanbeinstalledinaMatrix E7(refertoMatrix E7Chassis,Module
Placement,below,forplacementrules),Matrix N1,Matrix N3,Matrix N5,orMatrix N7
chassis.
TheMatrix N1,Matrix N3,Matrix N5,andMatrix N7chassissupportonlyDFEmodules
andtherearenoparticularrulesforinstallingmodules.
Matrix E7 Chassis, Module Placement
DependingonthemodulesbeinginstalledintheMatrixE7chassisandtohelpensure
properoperation,considerthefollowingexamplesandrulesformoduleplacementinthe
chassis.Figure 32showsfiveexamplesofchassismoduleplacement.Theseexamplesare
describedbelowalongwiththeapplicablemoduleplacementrule.
Downloaded from www.Manualslib.com manuals search engine
Backplane Connections and Installation Rules
3-4 Installation
Example 1 (Figure 3-2, A)
ShowsthechassisfullypopulatedwithDFEPlatinummodules(7xxxxx).Thesemodules
communicatewitheachotherviatheFTM2chassisbackplaneandactasasingle
switchingentitywithoneIPaddress.TheDFEPlatinummodulesareconfiguredusinga
CommandLineInterfacesetofcommands.
Rule:DFEPlatinummodulescanbeinstalledinanyavailablechassisslotintheMatrixE7
chassis.
Example 2 (Figure 3-2, B)
Showsthechassisfullypopulatedwiththirdgenerationmodules(6x3xx).Thesemodules
canalsobeinstalledinanyavailablechassisslotintheMatrixE7chassis,butoperateas
individualmoduleswithseparateIPaddresses.EachmoduleisconfiguredusingLocal
Management.
Rule:The6x3xxmodulescanbeinstalledinanyavailablechassisslotintheMatrixE7
chassis.
Example 3 (Figure 3-2, C)
Showschassisslots1through5populatedwithfirstandsecondgenerationmodules
(6x1xxand6x2xx).Ifa6x1xxor6x2xxseriesmoduleisinstalledinslot6or7,itwill
operateinstandalonemode(nobackplaneconnectivity).Likethe6x3xxmodules,the
6x1xxand6x2xxmodulesoperateasindividualmoduleswithseparateIPaddresses,and
eachoneisconfiguredusingLocalManagement.
Rule:The6x1xxand6x2xxmodulescancommunicatewitheachotherwhentheyare
installedinchassisslots1through5intheMatrixE7chassis.Ifinstalledinslot6or7,they
operateinstandalonemode.
Figure 3-2 Examples, Module Placement in Matrix E7 Chassis
7XXXXX 7H43X-XX
6X3XX
6X3XX
6X2XX 6X1XX
1 2 3 4 5 6 7
6X1XX
6X2XX
+
6X3XX
6X3XX
1 2 3 4 5 6 7
6X1XX
6X2XX
1 2 3 4 5 6 7
6X3XX
1 2 3 4 5 6 7
7XXXXX
1 2 3 4 5 6 7 1 2 3 4 5 6 7
6X3XX
6X3XX
6X2XX
7XXXXX
6X1XX
A E D C B F
Downloaded from www.Manualslib.com manuals search engine
Backplane Connections and Installation Rules
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-5
Example 4 (Figure 3-2, D)
Showschassisslots1through5populatedwithamixof6x1xx,6x2xx,and6x3xxmodules
andonlythirdgenerationmodulesinslots6and7.
Inthismodulearrangement,the6x3xxmoduleprovidesaproxybridge,whichenables
the6x1xxand6x2xxmodulestocommunicatewith6x3xxmodulesinslot6or7.Ifmore
thanone6x3xxmoduleisinstalledinslots1to5,themoduleinthelowestnumberedslot
performstheproxyfunctionforslots6and7.Therefore,ifa6x3xxmoduleisalready
performingtheproxyfunction,andanother6x3xxmoduleisinsertedintoalower
numberedslot,connectivitywillbetemporarilyinterrupted,asthenewboardtakesover
theproxyfunction.Whena6x3xxmoduleinalowernumberedslotisremoved,andthere
isa6x3xxmoduleinahighernumberedslot,communicationisnotinterrupted.
ForLocalManagement,pluggingtheLocalManagementconnectionintothe6x3xx
moduleswillallowmanagementconnectionstoall6x1xx,6x2xx,and6x3xxmodules.If
theLocalManagementconnectionistoa6x1xxor6x2xxboard,onlythemodulesinthe
firstfiveslotswillberecognizedbythemanagementclient.
Rule:Theremustbeatleastone6x3xxmoduleinslots1through5toenable
communicationsbetweenthe6x1xx,6x2xx,and6x3xxmodules.
Example 5 (Figure 3-2, E)
Showschassisslots1and5populatedwith6x1xx,6x2xxmodules,respectively;slots2
through4withDFEPlatinummoduleswithoutabridgingmodule;andslots6and7with
6x3xxmodules.
Inthismodulearrangement,the6x1xxand6x2xxmodulesinslots1and5canonly
communicatewitheachother,becausethereisno6x3xxmoduleinoneofthefirstfive
slotstoserveastheproxybridgetocommunicatewiththe6x3xxmodulesinslots6and7.
The7x4xxxDFEPlatinummodulesinslots2,3,and4willoperateunderoneIPaddress.
Sincethereisnobridgingmodule(7H438225,7H438249,7H438349,or7H438549),the
DFEPlatinummoduleswillnotcommunicatewithanyothermodulesinthechassis.
Rule:Inthisexample,theremustbeatleastone6x3xxseriesmodule,andabridging
module(7H438225,7H438249,7H438349,or7H438549)inslots1through5toenable
communicationsbetweenallgenerationsofmodulesinthechassis.
Example 6 (Figure 3-2, F)
ThemodulearrangementinthisexampleissimilartotheoneshowninFigure 32,E and
describedinExample5.Theonlydifferenceisthatabridgingmoduleisinstalledinslot2,
enablingallmodulestocommunicatewitheachother.
Rule: Inthisexample,the7H438225servesasboththeFTM1toFTM2bridgeandthe
fivetosevenslotproxybridge.The6x3xxdoesnotserveasaproxybridgeinthis
configurationbecausethe7H438225isinaslotwithalowernumber.Youcanusethe
7H438225,7H438249,7H438349,or7H438549asabridgingmoduledependingonthe
need.
Downloaded from www.Manualslib.com manuals search engine
Installing Module into Matrix E7 or Matrix N7 Chassis
3-6 Installation
INSTALLING MODULE INTO MATRIX E7 OR MATRIX N7 CHASSIS
ToinstallaDFEPlatinummoduleintoaMatrix E7orMatrix N7 chassis,proceeddirectly
toPreparationonpage 36tostarttheinstallationprocess.
Preparation
1. Removetheblankpanelcoveringtheslotinwhichthemodulewillbeinstalled.All
otherslotsmustremaincoveredtoensureproperairflowforcooling.(Savetheblank
plateintheeventyouneedtoremovethemodule.)
2. Removethemodulefromtheshippingbox.(Savetheboxandpackingmaterialsin
theeventthemoduleneedstobereshipped.)
3. Locatetheantistaticwriststrapshippedwiththechassis.Attachtheantistaticwrist
straptoyourwristandplugthecablefromtheantistaticwriststrapintotheESD
groundingreceptacleattheupperrightcornerofthechassis.
4. Removethemodulefromtheplasticbag.(Savethebagintheeventthemodulemust
bereshipped.)ObserveallprecautionstopreventdamagefromElectrostatic
Discharge(ESD).
5. Examinethemodulefordamage.Ifanydamageexists,DONOTinstallthemodule.
ImmediatelycontactEnterasysNetworks.RefertoGettingHelponpage xviii.
Caution: Failure to observe static safety precautions could cause damage to the
DFE-Platinum module. Follow static safety handling rules and wear the antistatic wrist
strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the
board or components can cause damage.
Precaucin: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad esttica, es posible que el mdulo se dae. Siga los consejos de seguridad
para la manipulacin del producto y no olvide utilizar la pulsera antiesttica.
No corte la bolsa antiesttica para sacar el mdulo. Tenga en cuenta que si algn objeto
cortante entra en contacto con la placa o con los componentes, stos podran daarse.
Downloaded from www.Manualslib.com manuals search engine
Installing Module into Matrix E7 or Matrix N7 Chassis
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-7
Installation
Toinstallthemodule,refertoFigure 33andproceedasfollows:
1. Locatethechassiscardguidesthatlineupwiththeslotnumberinwhichthe
modulewillbeinstalled.(Inthisexample,slot1isbeingused.)Makesurethe
modulelockingleversareintheopenposition(topandbottom).
2. Alignthemodulecardbetweentheupperandlowercardguidesofthedesiredslot
andslideitintothechassis,takingcarethatthemoduleslidesinstraight.SeeCaution
below.
3. Slidethemoduleintotheslotuntilyoucanengagethetopandbottomlockinglevers
withthechassisasshowninFigure 33.
4. RefertotheCautionnoteabove,thenrotatethetwoleversintotheclosedposition.
5. Ifthechassisinwhichthemoduleisinstalledwaspowereddownfortheinstallation,
turnthepowersupplieson.ChecktoseethatthemoduleCPULEDsettlesatsolid
greenafterafewminutes.IftheLEDdoesnotturnsolidgreen,refertoChapter 4for
troubleshootingdetails.
Caution: To prevent damaging the backplane connectors in the following step, take care
that the module slides in straight and properly engages the backplane connectors.
Ensure that the top lever lines up with the desired slot number located on the front panel of
the chassis. Refer to Figure 3-3.
Precaucin: Para evitar que se daen los conectores del panel posterior en el siguiente
paso, intente deslizar el mdulo en forma recta y verifique que se enganche
correctamente en los conectores de panel posterior.
Asegrese de que la palanca superior est alineada con respecto al nmero de ranura
correspondiente ubicado en el panel frontal del chasis. Consulte en Figure 3-3.
Caution: Due to the amount of force needed to properly seat the module connectors into
the backplane connectors, it is best to apply force to the end of the levers to insert (or
eject) the module. Otherwise, damage could result to the module and chassis.
Precaucin: Para colocar los conectores del mdulo en los conectores del panel
posterior correctamente es necesario hacer bastante fuerza, por ello, para insertar o quitar
el mdulo, se recomienda concentrar la fuerza en el extremo de las palancas. Si no lo
hace, podra daar el mdulo y el chasis.
Caution: In step 4, do not force the locking levers to the point that they touch the face of
the front panel. Forcing the locking levers to this point could damage the module and
chassis.
Precaucin: En el paso 4, tenga cuidado de no llevar las palancas de cierre a un punto
en donde estn en contacto con el panel frontal. Si lo hace, podra daar el mdulo y/o el
chasis.
Downloaded from www.Manualslib.com manuals search engine
Installing Module into Matrix E7 or Matrix N7 Chassis
3-8 Installation
Figure 3-3 Installing Module into Matrix E7 or Matrix N7 Chassis (E7 shown)
Card guides Upper/lower locking tabs (in proper open position)
Slot number 1 (Left-most slot is 1.) Upper/lower locking tab (in closed position)
Module card Backplane connectors
Metal back panel
- Top two connectors (power and FTM2)
- Bottom two connectors (power and FTM1) (no bottom
connectors in Matrix N7 chassis)
50/60Hz
LINE
100-125V~12A
200-240V~6A
50/60Hz
LINE
100-125V~12A
200-240V~6A
1
0
AC ON
POWER FAN
50/60Hz
LINE
100-125V~12A
200-240V~6A
50/60Hz
LINE
100-125V~12A
200-240V~6A
1
0
AC ON
POWER FAN
SERIES E7
4 5 6 7 1 2 3

COM
MGMT CPU
GROUP
SELECT
GROUP
1
2
3
4
5
1
2
3
4
5
6
7
8
7X
1X
15X
9X
23X
17X
31X
25X
39X
G
R
O
U
P
5
33X
7G4282-41
Gb ENET
OFFLINE/
RESET
G
R
O
U
P
4
G
R
O
U
P
3
G
R
O
U
P
1
G
R
O
U
P
2
DFE

Downloaded from www.Manualslib.com manuals search engine


Installing Module into Matrix N3, N5, or N1 Chassis
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-9
INSTALLING MODULE INTO MATRIX N3, N5, OR N1 CHASSIS
ADFEmodulecanbeinstalledinanyavailablechassisslot(1through3)intheMatrix N3
chassis,orslots1through5intheMatrix N5chassis,orintothesingleslotofthe
Matrix N1chassis.AllchassishavehorizontalslotsforDFEmodules.Toinstallthe
moduleintotheMatrix N3,N5,orN1chassis, refertoFigure 34andproceedasdescribed
inInstallingModuleintoMatrix E7orMatrix N7Chassisonpage 36.
Caution: Follow static safety handling rules and wear the antistatic wrist strap to prevent
damage to the DFE-Platinum module.
Do not cut the non-conductive bag to remove the DFE-Platinum module. Sharp objects
contacting the board or components can cause damage.
Precaucin: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad esttica, es posible que el mdulo se dae. Siga los consejos de seguridad
para la manipulacin del producto y no olvide utilizar la pulsera antiesttica.
No corte la bolsa antiesttica para sacar el mdulo. Tenga en cuenta que si algn objeto
cortante entra en contacto con la placa o con los componentes, stos podran daarse.
Caution: When setting the locking levers to the closed position, do not try to force the
locking levers to the point that they touch the face of the front panel. Forcing the locking
levers to this point could damage the module and chassis.
Precaucin: Al mover las palancas a la posicin de cerrado, tenga cuidado de no
llevarlas a un punto en donde estn en contacto con el panel frontal. Si lo hace, podra
daar el mdulo o el chasis.
Downloaded from www.Manualslib.com manuals search engine
Installing Module into Matrix N3, N5, or N1 Chassis
3-10 Installation
Figure 3-4 Installing Module into Matrix N3, N5, or N1 Chassis (N3 shown)
Card guides Upper locking tab (shown in closed position)
Slot 1 (Top slot is slot 3.) Lower locking tab (shown in closed position)
Module card FTM2 backplane connectors
Metal back panel
7C203-1
REDUNDANCY
PWR
100-125V~12.0A
200-240V~6.0A
50/60 Hz
7C203-1
REDUNDANCY
PWR
100-125V~12.0A
200-240V~6.0A
50/60 Hz

O
F
F
L
IN
E
/
R
E
S
E
T
C
O
M
M
G
M
T
C
P
U
3
2
1
G
R
O
U
P
S
E
L
E
C
T
G
R
O
U
P
123456789
1
01
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
7
G
4
2
0
2
-6
0
G
b
E
N
E
T
D
F
E

Downloaded from www.Manualslib.com manuals search engine


Connecting to the Network
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-11
CONNECTING TO THE NETWORK
Thissectionprovidestheproceduresforconnectingunshieldedtwistedpair(UTP)
segmentsfromthenetworkorotherdevicestothe7G428241(ConnectingUTPCablesto
7G420260or7G428241onpage 311).
Connecting UTP Cables to 7G4202-60or7G4282-41
ThefixedRJ45frontpanelconnectionsofthe7G420260and7G428241are10/100/
1000 Mbpsports.Theseportshaveinternalcrossovers,andalsosupportautomatic
polaritysensingwhenconfiguredforautomaticnegotiation.
Ifautomaticnegotiationisnotactivatedonaport,useastraightthroughcablewhen
connectingaworkstationtotheport.Whenconnectinganetworkingdevicetotheport,
suchasabridge,repeater,orrouter,useacrossovercable.
Ifaportissetforautonegotiation,automaticpolaritysensingisalsoactivated.
Automaticpolaritysensingeliminatestheneedforacrossovercable,regardlessifthe
connectionistoanothernetworkdeviceoraworkstation.
Inthisprocedure,the 7G420260isusedastheexampletoconnectatwistedpairsegment
tothemodule.Itisalsoassumedthatthechassispoweristurnedontoprovidepowerto
themodule.RefertoFigure 35andproceedasfollows:
1. EnsurethatthedeviceconnectedtotheotherendofthesegmentispoweredON.
2. ConnectthetwistedpairsegmenttothemodulebyinsertingtheRJ45connectoron
thetwistedpairsegmentintotheappropriateRJ45portconnector.
Note: If the DFE-Platinum module is being installed in a network using Link Aggregation,
there are rules concerning network cables and port configurations that must be followed
for Link Aggregation to operate properly. Before connecting the cables, refer to the
Enterasys Matrix DFE-Platinum Series Configuration Guide for the configuration
information. For details on how to obtain manuals, refer to the Related Documents in
About This Guide.
Note: All RJ45 front panel ports on the 7G4202-60and7G4282-41 support Category 5
Unshielded Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms.
Category 3 cable may be used if the connection is going to be used only for 10 Mbps.
Downloaded from www.Manualslib.com manuals search engine
Connecting to the Network
3-12 Installation
3. VerifythatalinkexistsbycheckingthattheportRX(Receive)LEDisON(flashing
amber,blinkinggreen,orsolidgreen).IftheRXLEDisOFFandtheTX(Transmit)
LEDisnotblinkingamber,performthefollowingstepsuntilitison:
a. Toviewthereceiveandtransmitactivityonagroupofsegments,pressthe
GROUPSELECTbutton(seeFigure 35)tosteptothegroupofinterest
(Groups1through3onthe7G420260,orGroups1through5onthe7G428241).
EachtimetheGROUPSELECTbuttonispressed,aGROUPLEDlightsupin
sequence,indicatingwhichGroupisselected.Thereceiveandtransmitactivity
forthatgroupofsegmentsisthenindicatedbytheRXandTXLEDsforeach
segment.
b. VerifythatthecablingbeingusedisCategory5UTPwithanimpedancebetween
85and111 ohms.Fortheporttooperateat100or1000Mbps,category 5cabling
mustbeused.
c. Verifythatthedeviceattheotherendofthetwistedpairsegmentisonand
properlyconnectedtothesegment.
d. VerifythattheRJ45connectorsonthetwistedpairsegmenthavetheproper
pinoutsandcheckthecableforcontinuity.Typically,acrossovercableisused
betweenhubdevices.Astraightthroughcableisusedtoconnectbetween
switchesorhubdevicesandanenduser(computer).RefertoFigure 36and
Figure 37forfourwireRJ45connections.RefertoFigure 38andFigure 39for
eightwireRJ45connections.
Figure 3-5 Connecting a Twisted Pair Segment to the DFE-Platinum Module
RJ45 connector Transmit status (TX) LED) GROUP SELECT button
RJ45 port connector Receive status (RX) LED
OFFLINE/
RESET
COM
MGMT CPU
3 2 1
GROUP
SELECT
GROUP
1
2
7G4202-60
Gb ENET

Downloaded from www.Manualslib.com manuals search engine


Connecting to the Network
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-13
Figure 3-6 Crossover Four-Wire Cable RJ45 Pinouts, Connections Between Hub
Devices
RJ45 device port RJ45-to-RJ45 crossover cable
Other device port RX+/RX- and TX+/TX- connections. These
connections must share a common color pair.
Figure 3-7 Straight-Through Four-Wire Cable RJ45 Pinouts, Connections
Between Switches and End User Devices
RJ45 device port RJ45-to-RJ45 straight-through cable
Other device port RX+/RX- and TX+/TX- connections. These connections
must share a common color pair.
TX+
TX
RX+
RX 2
1
3
6
TX+
TX
2
1
3
6
RX+
RX

TX+
TX
RX+
RX 2
1
3
6
TX+
TX
2
1
3
6
RX+
RX

Downloaded from www.Manualslib.com manuals search engine


Connecting to the Network
3-14 Installation
Figure 3-8 Eight-Wire Crossover Cable RJ45 Pinouts, Connections Between Hub
Devices
RJ45 device port RJ45-to-RJ45 crossover cable
Other device port
Figure 3-9 Eight-Wire Straight-Through Cable RJ45 Pinouts, Connections
Between Switches and End User Devices
RJ45 device port RJ45-to-RJ45 straight-through cable
Other device port
2
1
3
6
4
5
7
8
TX1+
TX2+
RX4-
RX1-
TX4+
RX3-
TX3+
RX2-
TX2+
TX1+
RX3-
RX2-
TX3+
RX4-
TX4+
RX1-
2
1
3
6
4
5
7
8

TX1+
TX2+
RX4-
RX1-
TX4+
RX3-
TX3+
RX2-
2
1
3
6
4
5
7
8
TX2+
TX1+
RX3-
RX2-
TX3+
RX4-
TX4+
RX1-
2
1
3
6
4
5
7
8

Downloaded from www.Manualslib.com manuals search engine


Connecting to COM Port for Local Management
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-15
e. EnsurethatthetwistedpairconnectionmeetsthedBlossandcablespecifications
outlinedintheCablingGuide.RefertoRelatedDocumentsinAboutThisGuide
forinformationonobtainingthisdocument.
Ifalinkisnotestablished,contactEnterasysNetworks.RefertoGettingHelpon
page xviiifordetails.
4. Repeatsteps1through3above,untilallconnectionshavebeenmade.
CONNECTING TO COM PORT FOR LOCAL MANAGEMENT
ThissectiondescribeshowtoinstallaUTPstraightthroughcablewithRJ45connectors
andoptionaladapterstoconnectaPC,aVTseriesterminal,oramodemtoan
Enterasys NetworksmoduletoaccessLocalManagement.Thissectionalsoprovidesthe
pinoutassignmentsoftheadapters.
What Is Needed
Thefollowingisalistoftheusersuppliedpartsthatmaybeneededdependingonthe
connection:
RJ45toDB9femaleadapter
UTPstraightthroughcablewithRJ45connectors
RJ45toDB25femaleadapter
RJ45toDB25maleadapter
WithaUTPstraightthroughcablewithRJ45connectorsandRJ45toDB9adapter,you
canconnectproductsequippedwithanRJ45COMporttoanIBMorcompatiblePC
runningaVTseriesemulationsoftwarepackage.
WithaUTPstraightthroughcableandRJ45toDB25femaleadapter,youcanconnect
productsequippedwithanRJ45COMporttoaVTseriesterminalorVTtypeterminals
runningemulationprogramsfortheVTseries.
WithaUTPstraightthroughcableandanRJ45toDB25maleadapter,youcanconnect
productsequippedwithanRJ45COMporttoaHayescompatiblemodemthatsupports
9600 baud.
Connecting to an IBM PC or Compatible Device
ToconnectanIBMPCorcompatibledevice,runningtheVTterminalemulation,toan
Enterasys NetworksmoduleCOMport(Figure 310),proceedasfollows:
1. ConnecttheRJ45connectoratoneendofaUTPstraightthroughcabletothe
communicationsCOMportontheEnterasys Networksmodule.(TheCOMportis
alsoknownasaConsoleport.)
Downloaded from www.Manualslib.com manuals search engine
Connecting to COM Port for Local Management
3-16 Installation
2. PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintoan
RJ45toDB9adapter .
3. ConnecttheRJ45toDB9adaptertothecommunicationsportontheIBMPC.
4. TurnonthePCandconfigureyourVTemulationpackagewiththefollowing
parameters:
5. Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheappropriateEnterasysMatrixDFEPlatinumSeriesConfigurationGuidefor
furtherinformation.
Parameter Setting
Mode 7 Bit Control
Transmit Transmit=9600
Bits Parity 8 Bits, No Parity
Stop Bit 1 Stop Bit
Figure 3-10 Connecting an IBM PC or Compatible
UTP straight-through cable with RJ45 connectors RJ45-to-DB9 PC adapter
RJ45 COM port IBM PC or compatible device
OFFLINE/
RESET
COM
MGMT CPU
3 2 1
GROUP
SELECT
GROUP
1
2
7G4202-60
Gb ENET

Downloaded from www.Manualslib.com manuals search engine


Connecting to COM Port for Local Management
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-17
Connecting to a VT Series Terminal
ToconnectaVTSeriesterminaltoanEnterasys NetworksDFEPlatinummoduleCOM
port(Figure 311),useaUTPstraightthroughcablewithRJ45connectorsandanRJ45to
DB25femaleadapter,andproceedasfollows:
1. ConnecttheRJ45connectoratoneendoftheUTPstraightthroughcabletothe
COMportontheEnterasys Networksmodule.
2. PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintothe
RJ45toDB25femaleadapter .
3. ConnecttheRJ45toDB25adaptertotheportlabeledCOMMontheVT
terminal .
4. TurnontheterminalandaccesstheSetupDirectory.Setthefollowingparameterson
yourterminal:
Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideforfurther
information.
Parameter Setting
Mode 7 Bit Control
Transmit Transmit=9600
Bits Parity 8 Bits, No Parity
Stop Bit 1 Stop Bit
Downloaded from www.Manualslib.com manuals search engine
Connecting to COM Port for Local Management
3-18 Installation
Connecting to a Modem
ToconnectamodemtoanEnterasys NetworksDFEPlatinummoduleCOMport
(Figure 312),useaUTPstraightthroughcablewithRJ45connectorsandanRJ45toDB25
maleadapter,andproceedasfollows:
1. ConnecttheRJ45connectoratoneendoftheUTPstraightthroughcabletothe
COMportoftheDFEPlatinummodule.
2. PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintothe
RJ45toDB25modemadapter .
3. ConnecttheRJ45toDB25adaptertothecommunicationsportonthemodem.
4. Turnonthemodem.
Figure 3-11 Connecting a VT Series Terminal
UTP straight-through cable with RJ45 connectors RJ45-to-DB25 VT adapter
RJ45 COM port VT series terminal
OFFLINE/
RESET
COM
MGMT CPU
3 2 1
GROUP
SELECT
GROUP
1
2
7G4202-60
Gb ENET

Downloaded from www.Manualslib.com manuals search engine


Connecting to COM Port for Local Management
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-19
5. WithaPCconnectedtoaremotemodem,youcanconfiguretheswitchremotely.
Toaccomplishthis,youmustconfigureyourPCVTemulationpackagewiththe
followingparameters.
6. Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideforfurther
information.
Parameter Setting
Mode 7 Bit Control
Transmit Transmit=9600
Bits Parity 8 Bits, No Parity
Stop Bit 1 Stop Bit
Figure 3-12 Connecting to a Modem
UTP straight-through cable with RJ45 connectors Local modem
RJ45 COM port Remote modem
RJ45-to-DB25 modem adapter
OFFLINE/
RESET
COM
MGMT CPU
3 2 1
GROUP
SELECT
GROUP
1
2
7G4202-60
Gb ENET

Downloaded from www.Manualslib.com manuals search engine


Connecting to COM Port for Local Management
3-20 Installation
Adapter Wiring and Signal Assignments
COM Port Adapter Wiring and Signal Diagram
RJ45 DB9
Pin Conductor Pin Signal
1 Blue 2 Receive (RX)
4 Red 3 Transmit (TX)
5 Green 5 Ground (GRD)
2 Orange 7 Request to Send (RTS)
6 Yellow 8 Clear to Send (CTS)
VT Series Port Adapter Wiring and Signal Diagram
RJ45 DB25
Pin Conductor Pin Signal
4 Red 2 Transmit (TX)
1 Blue 3 Receive (RX)
6 Yellow 5 Clear to Send (CTS)
5 Green 7 Ground (GRD)
2 Orange 20 Data Terminal Ready
RJ45 Connector (Female)
Pins
8 1
6 9
DB9 Connector (Female)
1 5
Pins
RJ45 Connector (Female)
Pins
8 1
DB25 Connector (Female)
Pins
25 14
13 1
Downloaded from www.Manualslib.com manuals search engine
Completing the Installation
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-21
COMPLETING THE INSTALLATION
CompletingtheDFEmoduleinstallationdependsonifthemoduleisbeinginstalledin:
anewDFEmodulesystem(refertoCompletingtheInstallationonpage 321),or
anestablished,operatingDFEmodulesystem(refertoCompletingtheInstallationof
aDFEPlatinumModuleinanExistingSystemonpage 323).
Completing the Installation of a New System
InanewsystemofDFEmodules,oneoftheinstalledDFEmoduleswillbecomethe
managementmoduleonchassispowerup,andallDFEmoduleswillautomaticallybeset
tothefactorydefaultvalues.Acompletelistofthefactorydefaultvaluesareprovidedin
Chapter3oftheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide.
AfterinstallingallDFEPlatinummodulesintothehostchassisandmakingthe
connectionstothenetwork,proceedtothefollowingFirstTimeLogInUsingaConsole
PortConnectionproceduretoaccessthemodulemanagementstartupscreenfromyour
PC,terminal,ormodemconnection.
Modem Port Adapter Wiring and Signal Diagram
RJ45 DB25
Pin Conductor Pin Signal
1 Blue 2 Transmit (TX)
2 Orange 8 Data Carrier Detect (DCD)
4 Red 3 Receive
5 Green 7 Ground (GRD)
6 Yellow 20 Data Terminal Ready (DTR)
8 Gray 22 Ring Indicator
RJ45 Connector (Female)
Pins
8 1
DB25 Connector (Male)
Pins
14 25
1 13
Downloaded from www.Manualslib.com manuals search engine
Completing the Installation
3-22 Installation
First-Time Log-In Using a Console Port Connection
StarttheCommandLineInterface(CLI)fromthemoduleslocalconsoleportasfollows:
1. ConnectaterminaltothelocalconsoleportasdescribedinConnectingtoCOMPort
forLocalManagementonpage 315.Thestartupscreen,Figure 313,displays.
2. Attheloginprompt,enteroneofthefollowingdefaultusernames:
roforReadOnlyaccess,
rwforReadWriteaccess,or
adminforSuperUseraccess.(ThisaccesslevelallowsReadWriteaccesstoall
modifiableparameters,includinguseraccounts.)
3. PressENTER.
4. ThePasswordpromptdisplays.LeavethisstringblankandpressENTER.The
moduleinformationandMatrixpromptdisplaysasshowninFigure 313.
TheDFEPlatinummoduleisnowreadytobeconfigured.Forinformationaboutsetting
theIPaddressandconfiguringTelnetsettingsforremoteaccesstoDFEmanagement,
refertoChapter3intheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide.TheCLI
commandsenableyoutoinitiallysetupandperformmoreinvolvedmanagement
configurations.
TheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideisavailableonlineat:
http://www.enterasys.com/support/manuals
Ifyourequireassistance,contactEnterasysNetworksusingoneofthemethodsdescribed
inGettingHelponpage xviii.
Note: This procedure applies only to initial log-in, and to logging in to a device not yet
configured with administratively-supplied user and password settings.
By default, the Matrix DFE Series device is configured with three user login accounts: ro
for Read-Only access; rw for Read-Write access; and admin for super-user access to all
modifiable parameters. The default password is set to blank (carriage return). For
information on changing these default passwords, refer to Chapter 3 in the Enterasys
Matrix DFE-Platinum Series Configuration Guide.
Downloaded from www.Manualslib.com manuals search engine
Completing the Installation
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 3-23
Completing the Installation of a DFE-Platinum Module in an Existing System
InanestablishedDFEmodulesystem,
aDFEmoduleisalreadyestablishedasthemanagementmodule,
thepasswordshavealreadybeensetforvarioususers,
thesystemIPaddressisset,and
othersystemparametershavebeenset.
WhenyouinstallanewDFEmoduleintoasystemwithanexistingconfigureduser
account,thecurrentsystemsettingsinthataccountarealreadyrecognizedbythenew
DFEmoduleanditwilloperateaccordingly.
Ifyouneedtochangeanysettings,youcanconnectaterminaltothelocalconsoleportas
describedinConnectingtoCOMPortforLocalManagementonpage 315toaccess
systemmanagement,oruseaTelnetconnectiontoaccesstheDFEmodulesystem
managementasdescribedinChapter3oftheEnterasysMatrixDFEPlatinumSeries
ConfigurationGuide.
Figure 3-13 Matrix DFE Startup Screen Example (N7 Chassis)
login: admin
Password:


M A T R I X N7
Command Line Interface

Enterasys Networks, Inc.
50 Minuteman Rd.
Andover, MA 01810-1008 U.S.A.

Phone: +1 978 684 1000
E-mail: support@enterasys.com
WWW: http://www.enterasys.com

(c) Copyright Enterasys Networks, Inc. 2003

Chassis Serial Number: xxxxxxxxxxxx
Chassis Firmware Revision: xx.xx.xx
Matrix N7(su)->
Downloaded from www.Manualslib.com manuals search engine
Completing the Installation
3-24 Installation
Logging in with an Administratively-Configured User Account
Ifthedevicesdefaultuseraccountsettingshavebeenchanged,proceedasfollows:
1. Attheloginprompt,enteryouradministrativelyassignedusernameandpress
ENTER.
2. AtthePasswordprompt,enteryourpasswordandpressENTER.
ThenoticeofauthorizationandtheMatrixpromptdisplaysasshownbackinFigure 313.
TheDFEPlatinummoduleisnowreadytobeconfigured.Forinformationaboutsetting
theIPaddressandconfiguringTelnetsettingsforremoteaccesstoDFEmanagement,
refertoChapter3intheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide.TheCLI
commandsenableyoutoinitiallysetupandperformmoreinvolvedmanagement
configurations.
TheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideisavailableonlineat:
http://www.enterasys.com/support/manuals
Ifyourequireassistance,contactEnterasysNetworksusingoneofthemethodsdescribed
inGettingHelponpage xviii.
Note: Users with Read-Write (rw) and Read-Only access can use the set password
command to change their own passwords. Administrators with Super User (su) access
can use the set system login command to create and change user accounts, and the set
password command to change any local account password. For information on the set
password and set system login commands, refer to Chapter 3 in the Enterasys Matrix
DFE-Platinum Series Configuration Guide.
Downloaded from www.Manualslib.com manuals search engine
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 4-1
4
Troubleshooting
Thischapterprovidesinformationconcerningthefollowing:
UsingLANVIEWonpage 41
TroubleshootingChecklistonpage 45
OverviewofDFEPlatinumModuleShutdownProcedureonpage 46
RecommendedShutdownProcedureUsingOFFLINE/RESETSwitchon
page 47
LastResortShutdownProcedureUsingOFFLINE/RESETSwitchonpage 48
Unlessotherwisenoted,thefollowinginformationappliestoallDFEmodules.
USING LANVIEW
Themodulesuseabuiltinvisualdiagnosticandstatusmonitoringsystemcalled
LANVIEW.TheLANVIEWLEDs(Figure 41)allowquickobservationofthenetwork
statustoaidindiagnosingnetworkproblems.
About the Management (MGMT) LED
TheMGMTLED(showninFigure 41)indicateswhenthemoduleisservingasthe
ManagementModuletocontrolthemanagementfunctionsforallDFEPlatinummodules
inthechassis.TheManagementModulehandlesallIPrequeststothechassisIPaddress,
suchasPING,Telnet,SNMP,HTTP,etc.TheManagementModulealsohandlestheCLI
configurationsessionsviatheconsoleport.So,whenyouplugintoaDFEPlatinum
moduleCOMporttoconfigureamoduleinthechassis,itishandledbytheManagement
ModuleregardlessoftheDFEPlatinummoduleCOMportthatyouuse.
Viewing the Receive and Transmit Activity
Onthe7G420260and7G428241,youcanviewthereceiveandtransmitactivityonthe
RXandTXLEDs.However,onlyonegroupofportsmaybeviewedatatime.Onthe
7G428241,thereare8portspergroup.Onthe7G420260,thereare20portspergroup.
Downloaded from www.Manualslib.com manuals search engine
Using LANVIEW
4-2 Troubleshooting
Toviewthereceiveandtransmitactivityonagroupofattachedsegments,pressthe
GROUPSELECTbutton(seeFigure 41)tosteptothegroupofinterest(Groups13for
the7G420260,andGroups15forthe7G428241).EachtimetheGROUPSELECTbutton
ispressed,theGROUPLEDlightsupinsequence,indicatingwhichgroupisselected.The
receiveandtransmitactivityforthatgroupofsegmentsisthenindicatedbytheRXand
TXLEDsforeachport.
Figure 4-1 LANVIEW LEDs
MGMT LED Group 1, Port 1 LEDs

OFFLINE/
RESET
COM
MGMT CPU
3 2 1
GROUP
SELECT
GROUP
1
2
7G4202-60
Gb ENET

1X
G
R
O
U
P
1
COM
CPU MGMT
GROUP
SELECT
GROUP
1
2
3
1
2
3
RX
TX
GROUP
GROUP
SELECT
GROUP
2 3
1
OFFLINE/
RESET

RX TX

7G4202-60
7G4282-41
1
GROUP
SELECT
7G4282-41
Gb ENET
Downloaded from www.Manualslib.com manuals search engine
Using LANVIEW
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 4-3
Table 42describestheLEDindicationsandprovidesrecommendedactionsas
appropriate.
The terms flashing, blinking, and solid used in Table 4-2 indicate the following:
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50%
off).
Solid indicates a steady LED light. No pulsing.
Alternating indicates an LED is flashing in a steady rate other than 50% on, 50%
off.
Table 4-2 LANVIEW LEDs
LED Color State Recommended Action
MGMT None Off. This module is NOT the
Management Module.
None.
Green Solid. This module is the
designated Management
Module.
None.
Amber Flashing. This is a
temporary indication that the
module is saving data.
None.
CPU None Power off. Ensure chassis has adequate power.
Amber Blinking. Module in process
of booting.
None.
Solid. Testing. If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
Green Blinking. Image starts
running.
None.
Solid. Functional. None.
Red Solid. Processor in reset. None.
Green
and
Amber
Blinking. Indicates that the
module is in the process of
shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to a start the process
of an orderly shutdown.
While in this state, do not remove any
DFE-Platinum module.
Downloaded from www.Manualslib.com manuals search engine
Using LANVIEW
4-4 Troubleshooting
Amber
and off
Alternating (67% on, 33%
off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
While in this state, you have 60 seconds
to safely remove the DFE-Platinum
module from the chassis.
RX
(Receive)
None No link. No activity. Port
enabled or disabled.
None.
Green Solid. Link present, port
enabled, no traffic is being
received by the interface.
None.
Amber Flashing. Link present, port
enabled, traffic is being
received by the interface.
None.
Red Blinking. Indicates
collisions. This indication is
only supported on 10/100
ports.
Contact Enterasys Networks for
technical support.
TX
(Transmit)
None Port enabled, but no activity. If it is known that the port should be
active and is not, contact Enterasys
Networks for technical support.
Green Flashing. Indicates data
transmission activity. Rate of
flashing indicates the data
rate.
None.
Red Flashing. Fault or Error
(collision).
None, unless there is a high rate of
activity. In this case, check for network
configuration problems or a defective
device.
Table 4-2 LANVIEW LEDs (Continued)
LED Color State Recommended Action
Downloaded from www.Manualslib.com manuals search engine
Troubleshooting Checklist
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 4-5
TROUBLESHOOTING CHECKLIST
Ifthemoduleisnotworkingproperly,refertoTable 43forachecklistofproblems,
possiblecauses,andrecommendedactionstoresolvetheproblem.
Table 4-3 Troubleshooting Checklist
Problem Possible Cause Recommended Action
All LEDs are OFF. Loss of power. Ensure that the module was installed properly
according to the installation instructions in
Chapter 3, and that the host chassis is providing
power.
No Local
Management
Password screen.
Incorrect terminal setup. Refer to the Enterasys Matrix DFE-Platinum
Series Configuration Guide for proper setup
procedures.
Improper console cable
pinouts.
Refer to Appendix A for proper COM port pinouts.
Corrupt firmware image,
or hardware fault.
If possible, attempt to download the image to the
module again. Refer to the section, Setting the
Mode Switches, on page B-1 for instructions to
clear NVRAM.
Cannot navigate
beyond Password
screen.
Improper username/
password combination
entered.
If the username/password combination has been
forgotten, refer to the section, Setting the Mode
Switches, on page B-1 for instructions on how to
set the mode switch to reset the username/
password combination to the default values.
Cannot contact the
module through
in-band
management.
IP address not
assigned.
Refer to the Enterasys Matrix DFE-Platinum
Series Configuration Guide for the IP address
assignment procedure.
Port is disabled. Enable port. Refer to the Enterasys Matrix DFE-
Platinum Series Configuration Guide for
instructions to enable/disable ports.
Host Port policy and/or
management VLAN is
incorrectly configured,
or not configured.
Verify that a management VLAN exists and that it
is associated with the Host Port.
Refer to the Enterasys Matrix DFE-Platinum
Series Configuration Guide for information about
Host Port and management VLAN configuration.
No link to device. Verify that all network connections between the
network management station and the module are
valid and operating.
If the problem continues, contact Enterasys
Networks for technical support.
Downloaded from www.Manualslib.com manuals search engine
Overview of DFE-Platinum Module Shutdown Procedure
4-6 Troubleshooting
OVERVIEW OF DFE-PLATINUM MODULE SHUTDOWN PROCEDURE
TheDFEPlatinummodulesinstalledinaMatrixE7,MatrixN1,MatrixN3,MatrixN5,or
MatrixN7chassisareinterdependentandoperateunderasingleIPaddressasasingle,
distributedswitchsystem(hardware,databases,andpersistentstorage).Inthisoperating
environment,theDFEPlatinummodulemustshutdowninanorderlyfashiontoensure
thattheothermodulesinthesystemandotherdevicesonthenetworkarenotifiedofthe
Port(s) goes into
standby for no
apparent reason.
Loop condition
detected.
Verify that Spanning Tree is enabled. Refer to the
Enterasys Matrix DFE-Platinum Series
Configuration Guide for the instructions to set the
type of STA.
Review the network design and delete
unnecessary loops.
If the problem continues, contact Enterasys
Networks for technical support.
User parameters
(IP address, device
and module name,
etc.) were lost
when the module
power was cycled,
the front panel
OFFLINE/RESET
switch was
pressed.
Position of Mode switch
(7), Persistent Data
Reset, was changed
sometime before either
cycling power or
pressing the OFFLINE/
RESET switch, causing
the user-entered
parameters to reset to
factory default settings.
Clear Persistent Data
that was set through
Local Management.
The module was moved
either from slot-to-slot
or from chassis-to-
chassis.
Reenter the lost parameters as necessary. Refer
to the Enterasys Matrix DFE-Platinum Series
Configuration Guide for the instructions to
configure the device.
If the problem continues, contact Enterasys
Networks for technical support.
Table 4-3 Troubleshooting Checklist (Continued)
Problem Possible Cause Recommended Action
Caution: Do not remove a DFE module from an operating chassis system before reading
the following information and instructions.
Precaucin: Antes de retirar los mdulos DFE del chasis en funcionamiento, lea las
siguientes instrucciones y la informacin suministrada.
Downloaded from www.Manualslib.com manuals search engine
Overview of DFE-Platinum Module Shutdown Procedure
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide 4-7
impendingchange.Thedevice(s)canthenmakeintelligentdecisionsandstabilizethe
networkbeforethechangeismade,therebyincreasingnetworkavailability.
YoucanshutdownaDFEPlatinummoduleinanoperatingsystemusingthe
OFFLINE/RESET switchshowninFigure 414.Therearetwoprocedurestoshutdowna
DFEPlatinummodule.
RecommendedShutdownProcedureUsingOFFLINE/RESETSwitch(page 47)
LastResortShutdownProcedureUsingOFFLINE/RESETSwitch(page 48)
Recommended Shutdown Procedure Using OFFLINE/RESET Switch
BeforepullingaDFEPlatinummoduleoutofachassis,
pressortaponitsOFFLINE/RESETswitchforlessthan1 second.
Figure 4-14 OFFLINE/RESET Switch
OFFLINE/RESET switch (in similar location on all DFE modules)
OFFLINE/
RESET
COM
MGMT CPU
3 2 1
GROUP
SELECT
GROUP
1
2
7G4202-60
Gb ENET

Caution: Do not pull any DFE-Platinum module out of an operating chassis before it has
completed its shutdown routine.
Precaucin: No retire los mdulos DFE del chasis en funcionamiento hasta que no se
haya terminado con la rutina de apagado.
Downloaded from www.Manualslib.com manuals search engine
Overview of DFE-Platinum Module Shutdown Procedure
4-8 Troubleshooting
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicating
thatthemoduleisshuttingdown.Attheendoftheshutdownroutine,theCPULED
changestoa67%/33%sequenceofamber/off,respectively,indicatingthemoduleisina
haltstate.Inthistimeitissafetorestartorremovethemodulefromthechassis.
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESET switch,youhave60
secondsfromthetimetheCPUstartsalternatelyflashingamber/offuntilthedevice
automaticallyrestarts.
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
ToresetaDFEPlatinummodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe OFFLINE/RESETswitchforapproximately6seconds.
PullinganyDFEPlatinummoduleoutofthechassisbeforeithasbeenshutdownisnot
recommended.Theonlysafetimetopullamoduleoutofthechassisisafterthe
completionofashutdownandthemanagementLEDisalternatelyflashingamber/off.
Note: The only safe time to pull a DFE-Platinum module out of the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.
Caution: This method of shutting down a DFE-Platinum module is not recommended
except as a last resort, because all processes currently running on the module will be
interrupted resulting in loss of frames.
Precaucin: No se recomienda utilizar este mtodo para apagar los mdulos DFE- Gold.
Recurra a l slo como ltimo recurso, puesto que interrumpe todos los procesos del
mdulo en funcionamiento, lo que podra resultar prdidas de frames.
Downloaded from www.Manualslib.com manuals search engine
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide A-1
A
Specifications
Thisappendixprovidesinformationaboutthefollowing:
DFEPlatinumModuleSpecificationsonpage A1
COMPortPinoutAssignmentsonpage A2
RegulatoryComplianceonpage A3
EnterasysNetworksreservestherighttochangethespecificationsatanytimewithout
notice.
DFE-PLATINUM MODULE SPECIFICATIONS
Table A1providestheI/Oports,processorsandmemory,physical,andenvironmental
modulespecificationsforthe7G420260and7G428241.Unlessnoteddifferently,the
specificationsapplytobothDFEmodules.
Table A-1 Specifications
Item Specification
7G4202-60 Ports
Ports 1 through 60 Sixty 10BASE-T/100BASE-TX/1000BASE-T compliant ports,
via sixty RJ45 connectors.
7G4282-41 Ports
Ports 1 through 40 Forty 10BASE-T/100BASE-TX/1000BASE-T compliant ports,
via forty RJ45 connectors.
Option Slot Supports one optional NEM.
Processors/Memory
Processor MPC750CX, 400 MHz processor
Dynamic Random Access
Memory (DRAM)
128 MB
FLASH Memory 32 MB
Downloaded from www.Manualslib.com manuals search engine
COM Port Pinout Assignments
A-2 Specifications
COM PORT PINOUT ASSIGNMENTS
TheCOMportisaserialcommunicationsportforlocalaccesstoLocalManagement.
RefertoTable A2fortheCOMportpinassignments.
Physical
Dimensions 46.43 H x 6.05 W x 29.51 D (cm)
18.28 H x 2.38 W x 11.62 D (in.)
Approximate Weight Gross: 5.54 kg (12.0 lb) (shipping carton containing
one module)
Net: 4.10 kg (9.0 lb) (one module without packaging)
Calculated hours for Mean Time
Between Failures (MTBF) for
7G4202-60 and 7G4282-41
For the MTBF hours for these products, refer to the MTBF web
site at URL
http://www.enterasys.com/support/mtbf/
Environmental
Operating Temperature 5C to 40C (41F to 104F)
Storage Temperature -30C to 73C (-22F to 164F)
Operating Relative Humidity 5% to 90% (non-condensing)
Table A-1 Specifications (Continued)
Item Specification
Table A-2 COM Port Pin Assignments
Pin Signal Name Input/Output
1 Transmit Data (XMT) Output
2 Clear to Send (CTS) Input
3 Data Set Ready (DSR) Input
4 Receive Data (RCV) Input
5 Signal Ground (GND) NA
6 Request to Send (RTS) Output
7 Data Terminal Ready (DTR) Output
8 Data Carrier Detect (DCD) Input
Downloaded from www.Manualslib.com manuals search engine
Regulatory Compliance
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide A-3
REGULATORY COMPLIANCE
The7G420260and7G428241meetthesafetyandelectromagneticcompatibility(EMC)
requirementslistedinTable A3:
Table A-3 Compliance Standards
Regulatory Compliance Standards
Safety UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950,
IEC 60950, EN 60825 and 21 CFR 1040.10.
Electromagnetic Compatibility
(EMC)
47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC,
EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024,
AS/NZS CISPR 22, and VCCI V-3.
Downloaded from www.Manualslib.com manuals search engine
Regulatory Compliance
A-4 Specifications
Downloaded from www.Manualslib.com manuals search engine
Regulatory Compliance
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide A-5
Downloaded from www.Manualslib.com manuals search engine
Regulatory Compliance
A-6 Specifications
Downloaded from www.Manualslib.com manuals search engine
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide B-1
B
Mode Switch Bank Settings and Optional Installations
Thisappendixcoversthefollowingitems:
RequiredToolsonpage B1
SettingtheModeSwitchesonpage B1
MemoryLocationsandReplacementProceduresonpage B3
REQUIRED TOOLS
Usethefollowingtoolstoperformtheproceduresprovidedinthisappendix:
Antistaticwriststrap
Phillipsscrewdriver
SETTING THE MODE SWITCHES
Figure B1throughFigure B3showthelocationofthemodeswitchesandtheswitch
settingsfornormaloperation.Theseswitchesaresetatthefactorytotheoffpositionand
rarelyneedtobechanged.
Caution: An antistatic wrist strap is required to perform the procedures in this appendix.
Use the antistatic wrist strap shipped with chassis when performing any of the procedures
in this appendix to minimize ESD damage to the devices involved.
Precaucin: Para llevar a cabo los procedimientos especificados en el apndice deber
utilizar una pulsera antiesttica. Para realizar cualquiera de los procedimientos
especificados en el apndice, no olvide utilizar la pulsera electrosttica que acompaa el
chasis para minimizar los efectos de las descargas de electricidad esttica.
Caution: Read the appropriate sections to be fully aware of the consequences when
changing switch settings.
Only qualified personnel should change switch settings.
Precaucin: Si desea modificar la configuracin del interruptor, lea las secciones
correspondientes para saber cul ser el resultado de hacerlo.
Estas modificaciones a la configuracin slo debe realizarlas personal calificado.
Downloaded from www.Manualslib.com manuals search engine
Setting the Mode Switches
B-2 Mode Switch Bank Settings and Optional Installations
Switchdefinitionsandpositionsareasfollows:
Switches1through6ForEnterasysNetworksuseonly.
Switch7ClearPersistentData.ChangingthepositionofthisswitchclearsPersistent
Dataonthenextpowerupofthemodule.Alluserenteredparameters,suchastheIP
address,modulenames,etc.,areresettothefactorydefaultsettings.Oncethemodule
resets,youcaneitherusethefactorydefaultsettingsorreenteryourownparameters.
Switch8ClearAdminPassword.Changingthepositionofthisswitchclearsthe
adminpassword,andrestoresthefactorydefaultpasswordonthenextpowerupof
themodule.Oncethemoduleresets,youcaneitherusethefactorydefaultsettingsor
reenteryourownpassword.
Note: Do not change the position of Switch 8 unless it is necessary to reset the admin
password to its factory default setting.
Figure B-1 Mode Switch Location on 7G4202-60 and 7G4282-41
Mode switch pack (7G4202-60 shown)
O
F F L I N
E /
R
E S E T
C
O
M
M
G
M
T
C
P U
3
2
1
G
R O
U
P
S E L E C
T
G
R O
U
P
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
2 0
7 G 4 2 0 2 - 6 0
G b E N E T
D
F
E

ON
1 2 3 4 5 6 7 8
Downloaded from www.Manualslib.com manuals search engine
Memory Locations and Replacement Procedures
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide B-3
MEMORY LOCATIONS AND REPLACEMENT PROCEDURES
IntheeventthattheDualInlineMemoryModule(DIMM)orDRAMSingleInline
MemoryModule(SIMM)(FLASHmemory)needstobereplaced,thefollowingsections
describehowtoaccess,locateandreplacethesememorymodules.Ifyouhavequestions
concerningthereplacementofeithermemorymodule,refertoGettingHelpon
page xviiifordetailsonhowtocontactEnterasys Networks.
Location of DRAM SIMM and DIMM Memory Modules
Figure B3andFigure B2showthelocationsoftheDRAMSIMMandDIMMontheeach
mainboardofthe7G420260 andthe7G428241,respectively.
Figure B-2 Memory Module Locations on the 7G4202-60
DIMM
1
1. This is not considered a field replaceable unit on the 7G4202-60.
DRAM SIMM Main PC board
O
F F L I N
E /
R
E S E T
C
O
M
M
G
M
T
C
P U
3
2
1
G
R O
U
P
S E L E C
T
G
RO
U
P
1
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
2 0
7 G 4 2 0 2 - 6 0
G b E N E T

D
F
E
Downloaded from www.Manualslib.com manuals search engine
Memory Locations and Replacement Procedures
B-4 Mode Switch Bank Settings and Optional Installations
DIMM Replacement Procedure (7G4282-41 only)
Removing the DIMM from 7G4282-41
ToremovetheDIMMfromthe7G428241,proceedasfollows:
1. IfanoptionalNEMisinstalledonthemainboardofthe7G428241,refertoFigure B4
onpage B5andproceedtostep1a.Otherwiseproceedtostep2.
a. RemoveandsavethethreescrewsattachingtheNEMtothefrontpanel.
Figure B-3 Memory Module Locations on the 7G4282-41
DIMM DRAM SIMM Main PC board

1
2
3
4
5
6
O F F L I N E /
R E S E TC
O
M
M
G
M
T
C
P U
G R O U P
S E L E C T
G
R O
U
P
1
2
3
4
5
1
2
3
4
5
6
7
8
7 X
GROUP 1
1 X
1 5 X
9 X
2 3 X
1 7 X
3 1 X
2 5 X
3 9 X
3 3 X
1
2
3
4
5
6
7 G 4 2 8 2 - 4 1
G b E N E T
GROUP2
GROUP3
GROUP4
GROUP5
7 G - 6 M
G B I C - A
1
2
3
4
5
6
D
F
E

1
2
3
4
5
6
O F F L I N E /
R E S E TC
O
M
M
G
M
T
C
P
U
G R O U P
S E L E C T
G
R
O
U
P
1
2
3
4
5
1
2
3
4
5
6
7
8
7 X
GROUP 1
1 X
1 5 X
9 X
2 3 X
1 7 X
3 1 X
2 5 X
3 9 X
3 3 X
1
2
3
4
5
6
7 G
4 2 8 2 - 4 1
G
b E N
E T
GROUP2
GROUP3
GROUP4
GROUP5
7 G
- 6 M
G
B
I C
- A
1
2
3
4
5
6
D
F
E
Note: The following DIMM replacement instructions apply to the 7G4282-41 only. The
DIMM is not considered a field replaceable part on the 7G4202-60. Contact
Enterasys Networks support if this part fails and needs a replacement.
Caution: Observe all Electrostatic Discharge (ESD) precautions when handling sensitive
electronic equipment.
Precaucin: Al trabajar con equipos electrnicos sensibles, tome todas las precauciones
de seguridad para evitar descargas de electricidad esttica.
Note: Prior to removing the DIMM from a 7G4282-41, you must remove the network
expansion module (NEM)to gain access to the DIMM memory and connector.
Downloaded from www.Manualslib.com manuals search engine
Memory Locations and Replacement Procedures
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide B-5
b. LifttheNEMstraightupandoffthetwomoduleconnectorsonthemainPC
board.
2. RefertoFigure B5.PushtheconnectorarmsawayfromtheDIMMand
simultaneouslylifttheDIMMenoughtoreleaseitfromtheconnectorfingers.
3. RotatetheDIMMupwards,thenremoveitfromtheconnectorfingers.
Figure B-4 NEM Removal and DIMM Connector Location on 7G4282-41
NEM (not on all DFE modules) DFE module front panel
Main PC board Module connectors on main board
Screws (3) DIMM memory module
Figure B-5 Removing the Existing DIMM from 7G4282-41
Connector arms DIMM Connector fingers

GROUP2
GROUP3
GROUP4
GROUP5
O F F L I N E /
R E S E TC
O
M
M
G
M
T
C
P
U
G R O U P
S E L E C T
G
R
O
U
P
1
2
3
4
5
1
2
3
4
5
6
7
8
7 X
1 X
1 5 X
9 X
2 3 X
1 7 X
3 1 X
2 5 X
3 9 X
3 3 X
1
2
3
4
5
6
7 G
4 2 8 2 - 4 1
G
b E N E T
7 G
- 6 M
G
B
I C
- A
1
2
3
4
5
6
D
F
E

Downloaded from www.Manualslib.com manuals search engine


Memory Locations and Replacement Procedures
B-6 Mode Switch Bank Settings and Optional Installations
Installing the DIMM on 7G4282-41
ToinstallaDIMM,refertoFigure B6andproceedasfollows:
1. InserttheDIMMdownbetweentheconnectorfingers.
2. PivottheDIMMdownwardsothetabsontheconnectorarmsalignwiththetwo
DIMMalignmentnotches.Withthetwoconnectorarmsspreadoutward,pushthe
DIMMdownbetweentheconnectorarms.Thenreleasethetwoconnectorarmsto
locktheDIMMintoplace.
Caution: Observe all Electrostatic Discharge (ESD) precautions when handling sensitive
electronic equipment.
Precaucin: Al trabajar con equipos electrnicos sensibles, tome todas las precauciones
de seguridad para evitar descargas de electricidad esttica.
Figure B-6 Installing the DIMM on 7G4282-41
DIMM Connector arms
Connector fingers Alignment notches (2)


Downloaded from www.Manualslib.com manuals search engine
Memory Locations and Replacement Procedures
Enterasys Matrix DFE-Platinum Series Hardware Installation Guide B-7
DRAM SIMM Replacement Procedure for 7G4202-60 and 7G4282-41
TheDRAMSIMMisconsideredafieldreplaceableunitonboththe7G420260and
7G428241.
Removing the DRAM SIMM
ToremovetheexistingDRAMSIMM,proceedasfollows:
1. LocatetheDRAMSIMMconnectoronthemainPCboard.ReferbacktoFigure B2.
2. PushtheconnectorarmsawayfromtheDRAMSIMM,asshowninFigure B7,
enoughtoreleasetheDRAMSIMMfromtheconnectorcontacts.
3. PulltheDRAMSIMMstraightupandremoveitfromtheconnectorcontacts.
Installing the DRAM SIMM on 7G4202-60 or 7G4282-41
ToinstallaDRAMSIMM,refertoFigure B8andproceedasfollows:
1. PushtheconnectorarmsawayfromtheDRAMSIMMenoughtoinserttheDRAM
SIMMintotheconnectorcontacts.
Caution: Observe all Electrostatic Discharge (ESD) precautions when handling sensitive
electronic equipment.
Precaucin: Al trabajar con equipos electrnicos sensibles, tome todas las precauciones
de seguridad para evitar descargas de electricidad esttica.
Figure B-7 Removing Existing DRAM SIMM from 7G4202-60 or 7G4282-41
Connector arms DRAM SIMM Connector contacts
Caution: Observe all Electrostatic Discharge (ESD) precautions when handling sensitive
electronic equipment.
Precaucin: Al trabajar con equipos electrnicos sensibles, tome todas las precauciones
de seguridad para evitar descargas de electricidad esttica.

Downloaded from www.Manualslib.com manuals search engine


Memory Locations and Replacement Procedures
B-8 Mode Switch Bank Settings and Optional Installations
2. InserttheDRAMSIMMstraightdownbetweentheconnectorcontactsenoughforthe
tabsontheconnectorarmstoalignwiththetwoDRAMSIMMalignmentnotches.
3. PushtheDRAMSIMMdownintotheconnectorcontacts.Thenrotatethetwo
connectorarmstowardtheDRAMSIMMtolockitintoplace.
Figure B-8 Installing the DRAM SIMM on 7G4202-60 or 7G4282-41
Connector arms Connector contacts
DRAM SIMM Alignment notches (2)

Downloaded from www.Manualslib.com manuals search engine


Index-1
Index
Numerics
1000BASE-T network connections
requirements for 2-2
100BASE-TX
requirements 2-2
10BASE-T
connection 3-11
requirements 2-2
7G4202-60
introduction to 1-2
7G4282-41
introduction to 1-2
C
Cable connections
7G4202-60 or 7H4282-41 3-11
Cable specifications
1000BASE-T network 2-2
100BASE-TX network 2-2
10BASE-T network 2-2
CLI command
introduction to 1-4
COM port connections
what is needed 3-15
Connecting to the network 3-11
Connectivity
DFE module and network expansion module 1-4
Console port
pinout assignments A-2
D
DFE-Platinum modules
introduction to 1-2
overview of capabilities 1-1
specifications for A-1
DIMM
replacement procedures for B-3
Document conventions xvii
E
Electromagnetic Compatibility (EMC)
requirements A-3
G
Getting help xviii
GROUP SELECT button
use of the 4-1
Guide
how to use xvi
I
Installation
connecting to the Network 3-11
module into Matrix E7 chassis 3-6
module into Matrix N1, N3, N5 chassis 3-9
module into Matrix N7 chassis 3-6
optional network expansion module 3-2
L
LANVIEW Diagnostic LEDs
use of 1-5
LANVIEW LEDs
use of 4-1
Local Management
COM port connections 3-15
introduction to 1-4
Login
administratively configured 3-24
M
Management
use of 1-4
Management (MGMT) LED
function of 4-1
Matrix E7 chassis
module installation into 3-6
Matrix N1, N3, N5 chassis
module installation into 3-9
Matrix N7 chassis
module installation into 3-6
Memory
DRAM SIMM replacement procedure B-7
Memory locations
DIMM and SIMM B-3
Mode Switch
setting of B-1
Module features 1-2
Downloaded from www.Manualslib.com manuals search engine
Index-2
N
NEM (network expansion module) 1-4
Network
connecting to 3-11
Network Requirements
list of 2-1
O
Optional Network expansion module
installation of 3-2
P
Pinout assignments
console port A-2
Pinouts
crossover 3-13, 3-14
straight-through 3-13, 3-14
R
Receive LEDs
viewing of 4-1
Regulatory Compliance A-3
Related manuals
obtaining xvi
Required Tools B-1
S
Safety requirements A-3
Secure Networks Policy 1-5
SIMMs
installing DIMM B-6
installing DRAM B-7
location B-3
Specifications A-1
DFE-Platinum module A-1
Standards compatibility 1-5
T
Technical support
contatacting Enterasys for xviii
Transmit LEDs
viewing of 4-1
Troubleshooting 4-1
checklist for 4-5
U
Unpacking the module 3-2
User Personalized Networks (UPN) See Secure
Networks Policy Support.
V
Viewing Receive and Transmit Activity
instructions for 4-1
W
WebView
introduction to 1-4