Professional Documents
Culture Documents
Solid-State Sensors
Wiring Instructions for Cables and Connectors
Bulletin No. 6008347001C May 1998 Raleigh, NC, USA Replaces 6008347001B dated 4/96
INTRODUCTION
This bulletin contains wiring instructions for a broad range of Telemecanique solid-state sensors.
CABLE WIRING
Cable
Sensor
Model SGO-8003, 8026, SGOB-8114, SGA-8005, 8040, 8018 SG1-8004, SG1B-8147 Suffix
Outputs
N.O. (blk) N.O. (wht) (grn) N.C. (blk) N.C. (wht) (grn) (blk) + (wht) (grn) 1 (blk) 2 (wht) (grn) Com (blk) N.O. (wht) N.C. (red) (grn) 1 (blk) 2 (red) 3 (wht) (grn) 1 (blk) 2 (org) 3 (wht) 4 (red) (grn)
= Ground
Connections
L1 Load L1 Load Load + L1 Load L1 Load Load L1 Load L2-heater + N.C. N.O.
DANGER
HAZARDOUS VOLTAGE
XSF-A
XSF-H, J
Sensor
Model SGO-8003, 8026, SGOB-8114, SGO-8110, SGA-8005, 8040, 8018 SG1-8004, SG1B-8147 SGO-8079, SG1-8056 SGC-8027, 8025 SGO-8110 Suffix 1 (grn) 347 (grn) (grn) N.O. (wht) 3 (wht)
Mini-Receptacle Connections
2 N.O. (red) N.C. (red) (red) N.C. (red) 2 (red) 3 N.O. (red) N.C. (red) + (red) (grn) (grn) 4 5
1 2 3
1 2 3
5 4
547
N.O. = Normally Open, N.C. = Normally Closed, N/C = No Connection, Com = Common,
Connector
3-pin mini style AC 3-pin micro style AC 4-pin micro style DC 5-pin mini style AC
Catalog No.
XSZ-CA9 XSZ-CK1 XSZ-CD BH20-5 For more details on ordering parts, please refer to the Square D Digest
Sensor
Model XUE-H3000, ZUE-Z04H7 XUJ-M1000 XUJ-LM1503
XUE-H, ZUE-Z03H7, XUR-H
XUJ-K
DC
1 2 3 2
1 3
AC Thru-Beam & Retroreflective XUJ-M/T AC Proximity (Diffuse) XUJ-LM XSB-A AC
N/C N/C N/C 4 XSF-H/J 2 N/C XS-7/8 (factory set jumper; N.O. for AC R30/K30, N.C. for R31/K31) N/C 4 XS-7/8 C40 PC/NC, XSC-H/J DC 2 N/C = No Connection Suffixes: * = Default wiring option, R = Mini, K = Micro, P = PNP, N = NPN, L = Light, D = Dark, 0 = N.O., 1 = N.C.
Sensor
Model XUE-F, ZUE-Z02H7 XUE-T, ZUE-Z05H7 Thru-Beam & Retroreflective XUJ-K Proximity(Diffuse)
Analog Thru-Beam & Retroreflective Proximity(Diffuse)
1 2 3
5 4
XUJ-M/T
XUJ-LM Light Mode Only XSC-H/J, XSD-H/J, XS7/8 C40 PC/NC XSF-H/J N/C = No Connection Suffixes: * = Default wiring option, , R = Mini, K = Micro, D = Dark, L = Light
PNP & NPN Inductive Sensors with N.O. & N.C. Outputs and 4-Pin Receptacles
Sensor
Model XS-7/8 C40 PC/NC, XSF-H/J, XSD-H/J Suffix
Receptacle
(Micro DC)
4 1 3 2
D4
Square D Company 8001 Hwy 64 East Knightdale, NC 27545 USA (919) 266-3671 2
Square D and
Electrical equipment should be serviced only by qualified electrical maintenance personnel. No responsibility is assumed by Square D for any consequences arising out of the use of this material. 1998 Square D All Rights Reserved