0

.02
.04
.06
.08
.1
.12
.14
P
i
p
e

T
h
i
c
k
n
e
s
s

(
i
n
.
)
.13

e))O4O E]- +)]g]
e))O4O e]C +)]g]
+]C_] e]C +)]g]
)_)C 1C +)]g

Original vs. Current Values
Minimum Allowed Wall Thickness
Minimum Measured Wall Thickness
Average Measured Wall Thickness
Original Wall Thickness
Average Thickness: 0.121
Corrosion Rate: 10.9
Percent of Allowable Pipe Loss: 32.2
Remaining Pipe Life: 2.4
Mils Per Year
Years
%
Average Pipe Loss: 0.0122 in.
in.
Average Case Scenario
August 2012
Estimated
Retirement
Minimum Thickness: 0.114
Percent of Allowable Pipe Loss: 50.0
May 2011
Remaining Pipe Life: 1.1
Corrosion Rate: 17.0 Mils Per Year
Years
Maximum Pipe Loss: 0.0190 in.
in.
Worst Case Scenario
Estimated
Retirement
%
Location No: 80
Pipe Approaching Retirement
Testing Indicates:
Comments:
Testing at this new steel pipe surprisingly identified low wall thickness and high corrosion
activity similar to estimates produced for other areas of the condenser water system.
Undersized pipe may partially contribute to this wall loss.
Depth Allowance: 0.0731
Minimum Theoretical Wall Thickness: 0.1111
Nominal Pipe Size: 1
Temperature: 75
In Service: 1.1
Actual Pipe Size: 1.32
Pipe Pressure: 60
Original Wall Thickness: 0.133 in.
PSIG
in.
Minimum Allowable Thickness: 0.095
Pipe Orientation: Horizontal
Test Site I.D.: 13-CW-1-27
Flow: Supply
Service: Condenser Water
Material: Carbon Steel
Schedule/Type: Schedule 40
Construction: Threaded
in.
Min:
Date of Previous Test:
Prior Measured Thickness: Avg.
Prior Corrosion Rate (MPY): Avg. Max:
Max: Difference in Rate (+/- MPY): Avg
Change in Status:
Prior Location No.: n/a n/a
No Prior Data to Compare
in.
in. ( )
Notes: Pipe exists 41 mils from the threads, see Addendum.
Years
Deg. F.
Standard Deviation: 0.0032 in.
in.

Test Pattern: Standard Grid
Minimum Thickness Based Upon:
Pitting Index: 5.6 % -- Moderate Pitting Activity
Comparison - Past to Present
High to Low Range:0.011 in.
Location - 13th Floor West MER: New steel corrosion coupon
rack, at length immediately above flowmeter. Test points located
between tee at flowmeter and elbow.
0.076
Graphical Summary Pipe Identification and Operating Conditions
Photo File #: 145h2-1-39.jpg
Orientation: Side View
Detail: Pipe Location
0
.02
.04
.06
.08
.1
.12
.14
P
i
p
e

T
h
i
c
k
n
e
s
s

(
i
n
.
)
.13
Individual Measurements

A 3 B 3 C 3 A 6
B 6 C 6 A 9 B 9
C 9 A 12 B 12 C 12
Test Results
May 11, 2010 Page 119
0
.02
.04
.06
.08
.1
.12
.14
P
i
p
e

T
h
i
c
k
n
e
s
s

(
i
n
.
)
.13

e))O4O E]- +)]g]
e))O4O e]C +)]g]
+]C_] e]C +)]g]
)_)C 1C +)]g

Original vs. Current Values
Minimum Allowed Wall Thickness
Minimum Measured Wall Thickness
Average Measured Wall Thickness
Original Wall Thickness
Average Thickness: 0.104
Corrosion Rate: 25.9
Percent of Allowable Pipe Loss: 76.3
Remaining Pipe Life: 0.3
Mils Per Year
Years
%
Average Pipe Loss: 0.0290 in.
in.
Average Case Scenario
August 2010
Estimated
Retirement
Minimum Thickness: 0.098
Percent of Allowable Pipe Loss: 92.1
May 2010
Remaining Pipe Life: 0.1
Corrosion Rate: 31.2 Mils Per Year
Years
Maximum Pipe Loss: 0.0350 in.
in.
Worst Case Scenario
Estimated
Retirement
%
Location No: 81
Pipe Approaching Retirement
Testing Indicates:
Comments:
Another example at this new corrosion coupon installation showing very high corrosion
activity, and with lowest wall thickness measurements approaching minimum limits. Threads
at the adjacent strainer and coupling are leaking; supporting this finding.
Depth Allowance: 0.0731
Minimum Theoretical Wall Thickness: 0.0940
Nominal Pipe Size: 1
Temperature: 75
In Service: 1.1
Actual Pipe Size: 1.32
Pipe Pressure: 60
Original Wall Thickness: 0.133 in.
PSIG
in.
Minimum Allowable Thickness: 0.095
Pipe Orientation: Horizontal
Test Site I.D.: 13-CW-1-28
Flow: Supply
Service: Condenser Water
Material: Carbon Steel
Schedule/Type: Schedule 40
Construction: Threaded
in.
Min:
Date of Previous Test:
Prior Measured Thickness: Avg.
Prior Corrosion Rate (MPY): Avg. Max:
Max: Difference in Rate (+/- MPY): Avg
Change in Status:
Prior Location No.: n/a n/a
No Prior Data to Compare
in.
in. ( )
Notes: Pipe exists 25 mils from the threads, see Addendum.
Years
Deg. F.
Standard Deviation: 0.0033 in.
in.

Test Pattern: Standard Grid
Minimum Thickness Based Upon:
Pitting Index: 5.8 % -- Moderate Pitting Activity
Comparison - Past to Present
High to Low Range:0.010 in.
Location - 13th Floor West MER: New steel corrosion coupon
rack. Test points located between strainer and elbow to
flowmeter.
0.076
Graphical Summary Pipe Identification and Operating Conditions
Photo File #: 145h2-1-41.jpg
Orientation: Side View
Detail: Pipe Location
0
.02
.04
.06
.08
.1
.12
P
i
p
e

T
h
i
c
k
n
e
s
s

(
i
n
.
)
.13
Individual Measurements

A 3 B 3 C 3 A 6
B 6 C 6 A 9 B 9
C 9 A 12 B 12 C 12
Test Results
May 11, 2010 Page 120
0
.02
.04
.06
.08
.1
.12
.14
P
i
p
e

T
h
i
c
k
n
e
s
s

(
i
n
.
)
.13

e))O4O E]- +)]g]
e))O4O e]C +)]g]
+]C_] e]C +)]g]
)_)C 1C +)]g

Original vs. Current Values
Minimum Allowed Wall Thickness
Minimum Measured Wall Thickness
Average Measured Wall Thickness
Original Wall Thickness
Average Thickness: 0.108
Corrosion Rate: 22.1
Percent of Allowable Pipe Loss: 65.1
Remaining Pipe Life: 0.6
Mils Per Year
Years
%
Average Pipe Loss: 0.0248 in.
in.
Average Case Scenario
November 2010
Estimated
Retirement
Minimum Thickness: 0.091
Percent of Allowable Pipe Loss: 100.0
April 2010
Remaining Pipe Life: 0.0
Corrosion Rate: 37.5 Mils Per Year
Years
Maximum Pipe Loss: 0.0420 in.
in.
Worst Case Scenario
Estimated
Retirement
%
Location No: 82
Pipe Replacement Indicated
Testing Indicates:
Comments:
Testing shows noticeably higher pitting activity at this example of pipe, and indicates a
corrosion condition rather than undersized pipe. Deep pitting is found in one area at below
minimum limits. No reliable service life remains.
Depth Allowance: 0.0731
Minimum Theoretical Wall Thickness: 0.0805
Nominal Pipe Size: 1
Temperature: 75
In Service: 1.1
Actual Pipe Size: 1.32
Pipe Pressure: 60
Original Wall Thickness: 0.133 in.
PSIG
in.
Minimum Allowable Thickness: 0.095
Pipe Orientation: Vertical
Test Site I.D.: 13-CW-1-29
Flow: Supply
Service: Condenser Water
Material: Carbon Steel
Schedule/Type: Schedule 40
Construction: Threaded
in.
Min:
Date of Previous Test:
Prior Measured Thickness: Avg.
Prior Corrosion Rate (MPY): Avg. Max:
Max: Difference in Rate (+/- MPY): Avg
Change in Status:
Prior Location No.: n/a n/a
No Prior Data to Compare
in.
in. ( )
Notes: Pipe exists 18 mils from the threads, see Addendum.
Years
Deg. F.
Standard Deviation: 0.0092 in.
in.

Test Pattern: Standard Grid
Minimum Thickness Based Upon:
Pitting Index: 15.9% --Significant Pitting Activity
Comparison - Past to Present
High to Low Range:0.026 in.
Location - 13th Floor West MER: New steel corrosion coupon
rack, length at right side coupon. Test points located between tee
at coupon holder and bottom elbow.
0.076
Graphical Summary Pipe Identification and Operating Conditions
Photo File #: 145h2-1-42.jpg
Orientation: Side View
Detail: Pipe Location
0
.02
.04
.06
.08
.1
.12
P
i
p
e

T
h
i
c
k
n
e
s
s

(
i
n
.
)
.13
Individual Measurements

A 3 B 3 C 3 A 6
B 6 C 6 A 9 B 9
C 9 A 12 B 12 C 12
Test Results
May 11, 2010 Page 121