GE Consumer & Industrial Power Protection

HabiTEQ

TM

Flexible home automation for energy efficiency, safety and comfort

GE imagination at work

HabiTEQTM The pre-wired solution for home automation


HabiTEQ is a user-friendly distribution board, designed and made to suit your home automation requirement. It comes tted and completely pre-wired with all the necessary electrical protection and automation components. HabiTEQ distribution boards are suited for both modern electrical installation and refurbishments, perfectly suited for apartments, residential homes and villas.
This intelligent plug and play automation solution has been designed for easy installation and time saving, requiring only a competent electrician to get things up and running. The system is exible, allowing addition of various automation blocks like intelligent switches, detectors, displays, SMS and web interface devices to enhance or achieve desired functionality. Once in place the system can be programmed using a PC through a serial link, giving the home owner complete control over lighting, heating, security and blinds through a choice of interfaces, bringing a whole new level of convenience to his living space. HabiTEQ comes in distribution boards that can be tailored for complete home automation solutions.

HabiTEQTM

Flexible solution for smart & simple electrical installations !


Seamlessly integrating safety, security, lighting, climate, automated barriers and more ..!! HabiTEQ provides comfort, control and convenience through multiple stylish user interface (touch screen, switches etc..).. Easy to install and customize. Using a PC through a choice of serial OR ETHERNET link, adds tangible value to builders, installers and home owners whatever the property: apartments, family homes, villas..

HabiTEQTM Intelligence Inbuilt 2 3

HabiTEQTM

HabiTEQTM

Home automation modules


Fast & Flexible two wire Bus system Quick & Easy configuration Plug&Play operation!
CTL16 up to 256
Controller

INP08/16
Input module

INP08/230
Input module

SMS01
Mobile interface module

ETH02 E
Ethernet module

REL04
4 Relay module

ROL02
2 Shutter relay module

DIM 04/500
Dimmer module

500VA

DIM04/300
Dimmer module

REL08
8 Relay module

300VA

ANR04
Analogue dimmer module for uorescent tubes

ANA04
Analogue dimmer module

Separate cable compartment (enclosure types C-D-E-F) Enclosure shown is type C7. (See p.10)

HabiTEQTM
Controlled outputs

HabiTEQTM
M
Motor

Protection equipment
Quick & Easy installation

Relay

Dimmer

Potential free and analogue inputs Connections from push-buttons, magnetic contacts and external detectors to input module.

MCBs for line protection

M R

RCDs for people protection


D

Bus connection

Surge protection Screwless terminals for quick connection Conventional cabled and controlled socket-outlets

Overvoltage protection

Contactors for controlled socket-outlets

HabiTEQTM

HabiTEQTM

8 types of enclosures to suit every requirement


Type A
Fix-o-Rail 150

Type B-F
Fix-o-Rail 144 F

Type B-S
Fix-o-Rail 144 S

Type B
VP-SYSTEM MV/MS

Surface Mounting

Flush Mounting

Surface Mounting

MW= Wall Mounting MS= Floor Standing

Rows 4

Type A
FOR 150

Code A4

HxWxD 750x355x150

Mod/Row Total Mod 18 72

Rows 4 5 6

Type B-F
FOR 144F FOR 144F FOR 144F

Code B4F B5F B6F

HxWxD 800x740x(35)140 950x740x(35)140 1100x740x(35)140

Mod/Row Total Mod 24 24 24 96 120 144

Rows 4 5 6

Type B-S
FOR 144S FOR 144S FOR 144S

Code B4S B5S B6S

HxWxD 800x740x140 950x740x140 1100x740x140

Mod/Row Total Mod 24 24 24 96 120 144

Rows 4 5 6 7 8 9 12

Type B
VP MW VP MW VP MW VP MW VP MW VP MW VP MS

Code B4 B5 B6 B7 B8 B9 BS12

HxWxD 650x550x210 800x550x210 950x550x210 1100x550x210 1250x550x210 1400x550x210 1980x550x210

Mod/Row Total Mod 24 24 24 22 22 22 20 96 120 144 154 176 198 240

Standard: - equipped with compact MCBs Unibis. - external wiring directly on input modules. - cables from socket circuits directly on MCBs - wiring of controlled outputs on terminals. - single phase 40A

Standard: - external wiring directly on input modules. - cables from socket circuits directly on MCBs - wiring of controlled outputs on terminals. Optional: equipped with compact MCBs Unibis (max.40A).

Standard: - external wiring directly on input modules. - cables from socket circuits directly on MCBs - wiring of controlled outputs on terminals. Optional: equipped with compact MCBs Unibis (max.40A).

Standard: - external wiring directly on input modules. - cables from socket circuits on terminals - wiring of controlled outputs on terminals. Optional: equipped with compact MCBs Unibis (max.40A).

HabiTEQTM

HabiTEQTM

Type C
VP-SYSTEM MW/MS

Type D
VP-SYSTEM MW/MS

Type E
VP-SYSTEM MW

Type F
Quixtra 630

Rows 5 6 7 8 9 12

Type C
VP MW VP MW VP MW VP MW VP MW VP MS

Code C5 C6 C7 C8 C9 CS12

HxWxD 800x800x210 950x800x210 1100x800x210 1250x800x210 1400x800x210 1980x800x210

Mod/Row Total Mod 22 22 22 22 22 22 110 132 154 176 198 264

Rows 5 6 7 8 9 12

Type D
VP MW VP MW VP MW VP MW VP MW VP MS

Code D5 D6 D7 D8 D9 DS12

HxWxD 800x1050x210 950x1050x210 1100x1050x210 1250x1050x210 1400x1050x210 1980x1050x210

Mod/Row 34 34 34 34 34 34

Total Mod 170 204 238 272 306 408

Rows 5 6 7 8 9

Type E
VP MW VP MW VP MW VP MW VP MW

Code E5 E6 E7 E8 E9

HxWxD 800x1300x210 950x1300x210 1250x1300x210 1400x1300x210 1980x1300x210

Mod/Row Total Mod 38 38 38 38 38 190 228 266 304 342

Rows 5 6 7 8 9 10 12

Type
QuiXtra 630 QuiXtra 630 QuiXtra 630 QuiXtra 630 QuiXtra 630 QuiXtra 630 QuiXtra 630

Code F5 F6 F7 F8 F9 F10 F12

HxWxD 750x1240x250 900x1240x250 1050x1240x250 1200x1240x250 1600x1240x250 1750x1240x250 2050x1240x250

Mod/Row Total Mod 36 36 36 36 36 36 36 180 216 252 288 324 360 432

Standard: - separate cable compartment (in- and outgoing cables) - cables from socket circuits on terminals. - wiring of controlled outputs on terminals. - wiring of inputs on terminals. Optional: equipped with compact MCBs Unibis (max.40A).

Standard: - separate cable compartment (in- and outgoing cables) - cables from socket circuits on terminals. - wiring of controlled outputs on terminals. - wiring of inputs on terminals. Optional: equipped with compact MCBs Unibis (max.40A).

Standard: - separate cable compartment (in- and outgoing cables) - cables from socket circuits on terminals - wiring of controlled outputs on terminals. - wiring of inputs on terminals. Optional: equipped with compact MCBs Unibis (max.40A).

Standard: -separate cable compartment (in- and outgoing cables) - cables from socket circuits on terminals - wiring of controlled outputs on terminals. - wiring of inputs on terminals. Optional: - equipped with compact MCBs Unibis (max.40A). - plain door (modules compartiment)

10

11

HabiTEQTM
L 16A N 230VAC 50Hz

HabiTEQTM
Controllers ontrollers

Automation Modules
Relay Modules

FUSE 1AT

Ph

230V N OUT1 OUT2 OUT3 OUT4

50Hz
Each contact: Max. switched current: 16A at 230Vac Max. switched Power: 2000VA

1...................................................................... 2. ..................................................................... 3. ..................................................................... 4. .....................................................................

RELAYMODULE REL04 SERIAL

BUS BUS A1 A2 A1 A2

Controllers
The controller is the central brain of the HabiTEQ automation system and delivers the necessary power and data to all the connected modules. The controller is available in 6 different versions to suit your installation size ensuring optimized costs. The power supply is delivered via a stabilized 18Vdc/2A lead (included). In case of a voltage cut-off a built-in back-up memory will save all data for at least 10 years. The connection from the power supply to the controller has no polarity.

Relay Modules
A choice of 3 different relay modules is offered to suit your switching application. The relay module has 4 or 8 normally open, independently controlled contacts that can handle up to 16A each. The relay module does not have any specic function. It can handle all switching functions: monostable (bell), bistable (on/off), timer, interval, thermostat output, etc. For shutter/blind/curtain control, the shutter module ROL02 must be used. For heavy inductive loads (many uorescent lights) with a high capacity or bipolar applications, contactors need to be added. The relay module contact will then activate the coil of the contactor. Each of the relay outputs have a unique serial number (E.g REL08 has therefore 2 serial numbers) enabling programming anywhere and anytime. All programming remains internally stored in a nonvolatile memory. After a voltage cut-off, the outputs return to their latest position. A bipolar automatic fuse with a maximum of 16A must be placed on the feeder.
M

L 16A

NC

OUT1

OUT2

OUT3
SERIAL

OUT4

230V 50Hz

RELAYMODULE REL08
1. .................................... 5. .................................... 2. ..................................... 6. ....................................
Each contact: max. switched current: 16A at 230Vac

3. .................................... 7. ....................................

4. .................................... 8. ....................................

SERIAL

OUT5

OUT6

OUT7

OUT8

BUS BUS A1 A2 A1 A2

L 16A N 230VAC 50Hz M1 M2

L 16A L 16A N 230VAC 50Hz N 230VAC 50Hz

POWER SUPPLY
18Vdc/3,9A

POWER SUPPLY
18Vdc/3,9A

FUSE 1AT

Ph

230V N 50Hz

Ph

UP1 NC DN1 Ph

UP2 NC DN2

Each contact: Max. switched current: 16A at 230Vac Max. switched Power: 2000VA

1...................................................................... 2. ..................................................................... 3. ..................................................................... 4. .....................................................................

FUSE 1.2 AT

POWER 18Vdc/1.4A

FUSE 1 AT

POWER 18Vdc/1.4A

CONTROLLER CTL256-BEX02

FUSE 1 AT

POWER
18Vdc/1.4A

CONTROLLER CTL 16 ..........256

BUS1 - BUS2: Nominal tension : 12Vdc Max. current : 500mA


BUS1 BUS1 A1 A2 A1 A2 BUS2 BUS2 A1 A2 A1 A2 BUS1 BUS1 A1 A2 A1 A2

BUS1 - BUS2: Nominal tension : 12Vdc Max. current : 500mA


BUS2 BUS2 A1 A2 A1 A2 BUS1 BUS1 A1 A2 A1 A2

BUS1 - BUS2: Nominal tension : 12Vdc Max. current : 500mA


BUS2 BUS2 A1 A2 A1 A2

UP/DOWN ROL02 SERIAL

BUS A1 A2

BUS A1 A2

Modules

Modules

Modules

Modules

Modules

RELAY MODULES Power supply Max. protection needed Bus load Characteristic consumption Internal fuse Insulation voltage Fitting

REL04

REL08 AC 230V +/- 10%, 50..60Hz - maximum 16A/2P 10mA at nominal 13,8V

ROL02 (Shutter/Blinds)

4.7VA maximum (all relays ON)

9.6 VA maximum (all relays on) 3 kV (tested) DIN rail Ouputs

2.8VA (typical) 6.3A

100mA (relay control power)

Type CONTROLLERS Power supply Output bus Characteristic consumption Number of outputs Bus connections Logical functions Protection - fuse Fitting Dimensions Sequences or scenes Back-up memory time 8 6 modules (105mm) 16 32 10 years Dimensions 1 AT DIN rail 9 modules 128 12 modules LED indication 16 32 2 (500mA) AND/OR/ IF.. THEN.. ELSE.. 1AT 1AT Maximum switching power 64 CTL16 CTL32 CTL64 CTL256 CTL256BEX02 CTL256BEX04 2 x 18Vdc/3,9A Rated current Contact resistance 388 4(500mA) 6(500mA) Set/Reset time Endurance Rated load 18Vdc/3,9A (supplied with controller) 13,8Vdc/500mA 2VA typical ( with no bus load)

OUT1OUT4: 4 normally open single contacts

OUT1OUT8: 8 normally open single contacts 16A (resistive @ 230Vac and 30Vdc) 100mOhm 15ms max / 5ms max 20mil operations

UP1/2 DN1/2: 4 potential-free normally open single contacts UP1 DN1 and UP2 DN2: internally locked contacts

Resistive load (cos phi = 1) 16A at 230Vac; 16A at 30Vdc Inductive load (cos phi = 0,4; L/R=7ms) 8A at 230Vac; 8A at 30Vdc Resistive load (cos phi=1) 2300VA at 230 Vac 300W at 30Vdc Inductive load (cos phi=0,4; L/R=7ms) 1150VA at 230Vac 150W at 30Vdc Green light: power supply Red light: Start-up 2 s, and during programming Orange light 1-X : Output 1 to x active 6 modules 9 modules Green light: power supply Red light: Start-up 2 s, and during Orange light 1-4: Up1/2Dn1/2 active 6 modules

12

13

HabiTEQTM

HabiTEQTM

Dimmer Modules
Choices of 4 different dimmer modules are offered to suit a variety of dimming applications. The modules are controlled and programmable through the bus operating digitally with 8-bit precision. An optical separation between the inputs and outputs guarantees safe operation. Multiple possibilities for dimmer control 1. One-button dimmer - Possible to reduce the number of control buttons. 2. Two-button dimmer - + and a button enhancing the operating comfort.
L 10A

Dimmer Modules

Analogue dimmer ANR04


Each analog output controls a relay contact, which releases when the output is on 0. This contact can disrupt the mains voltage so that the uorescent lamps go out completely. There are four internal DIP switches. These can be used to set each output to 0-10V or 1-10V. It must be noted that the control voltages must not be connected to the mains. The negative terminals are internally linked. The control and programming is done through the 2-wire bus, one or two button dimmer control.

L N

16A

230VAC 50Hz

Dimmable ballasts

Ph

230V N 50Hz

OUT1

OUT2

OUT3

OUT4

SW1

SW2

Each output: 0-10Vdc or 1-10vdc Max Current 5ma

1................................................................................................. 2. ................................................................................................ 3. ................................................................................................ 4. ................................................................................................

Each contact: max 16A/250Vac

DIMMER ANR04

BUS A1 A2

BUS A1 A2

SW3

SW4

When a pressed button is kept in, the transit time from zero to maximum is 5.1s. A short pulse (< 0.3s) will take the dimmer to zero or to the maximum value in 2.5s. The maximum value can be adjusted from 20 to 100%. The lighting can also be dimmed automatically after a set time of 1s to 255min. ideal for bedrooms If the dimmers are controlled by a sequence the rise time and fall time can be adjusted independently between 0.3s and 20min. Each module has a unique serial number enabling programming anywhere and anytime. After a voltage cut-off the outputs return to their latest position.

N 230VAC 50Hz

2AF

2AF

2AF

2AF

FUSE 6.3AF

Ph

230V N 50Hz

OUT1

OUT2

OUT3

OUT4

Cach output Resistive load or inductive load Max. switched Power: 300VA/230Vac

1.................................................................................. 2. ................................................................................. 3. ................................................................................. 4. .................................................................................

DIMMER DIM04/300

BUS A1 A2

BUS A1 A2

DIMMERS Power supply Max. protection needed Bus load Characteristic consumption Internal fuse Fitting Insulation voltage
FUSE 6.3AF
Ph

DIM04/300

DIM04/500

ANA04

ANR04 Analogue dimmer modules 16A/2P

Forward phase dimmer modules

Dimmer module DIM04/300-500


Module for a DIN-rail, suitable for dimming 4 loads of 40300/500VA. The phase offset of each load is measured separately thus allowing the use of resistive (light bulbs) and inductive loads (conventional transformers). Electronic transformers can be used if they operate according to the phase leading principle. For the 300VA dimmer modules a 2AF type fuse must be provided per output. Ensure adequate ventilation in the fuse box. On the 500VA dimmer modules,each dimmer output is fused internally with a 4AF fuse. A bipolar automatic fuse of a maximum of 16A must be placed on the mains power. Note an additional lter module will be supplied with 300/500Va dimmers
L

L
N

16A

AC 230V, 50Hz - maximum (60Hz on request) 10A/2P 10mA at 13,8V 2.8VA 6.3A 2.5VA 4 X 4AF NA DIN rail 3kV OUT1 OUT4 : Dimmable outputs 300Va/channel OUT1 OUT4 : Dimmable outputs 500VA/channel OUT1 OUT4 : Analogue outputs, 0-10V or 1-10V / channel OUT1 OUT4 : Analogue outputs, 0-10V or 1-10V SW1 SW4 : 4 normally open single contacts 10mA 1.5VA -

230VAC 50Hz

230V N 50Hz

OUT1

OUT2

OUT3

OUT4

Cach output Resistive load or inductive load Max. switched Power: 300VA/230Vac

1.................................................................................. 2. ................................................................................. 3. ................................................................................. 4. .................................................................................

Type

DIMMER DIM04/500

BUS A1 A2

BUS A1 A2

Maximum load Minimum load LED indication

Incandescent load 300VA Incandescent load 500VAat 230VAC at 230VAC 30% of maximum output

Green light : power supply Red light : Start-up 2 s, and during programming 9 modules 6 modules Orange light 1-4 : Output 1 to 4 active 16A 100mOhm 20mil operations
Resistive load (cos phi = 1) 16A at 230Vac; 16A at 30VDC Inductive load (cos phi = 0,4; L/R=7ms) 8A at 230Vac; 8A at 30VDC Resistive load (cos phi=1) 2300VA at 230 VAC300W at 30VDC
Inductive load (cos phi=0,4; L/R=7ms) 1150VA at 230VAC 150W at 30VDC

DIP switches
16A

6 modules

4 internal DIPswitches to select the outputs as 0-10V or 1-10V

Analogue dimmer ANA04


Suitable for controlling four analog dimmers operating with input voltages of 0-10V or 1-10V. This module can be used for dimming very large capacities. There are four internal DIPswitches. These can be used to set each output to 0-10V or 1- 10V. It must be noted that the control voltages must not be connected to the mains. The negative terminals are internally linked. The control and programming are done through the 2-wire bus, one or two button dimmer control.

Rated current Contact resistance Endurance Rated load


Dimmable ballasts

230VAC 50Hz

Maximum switching power Dimensions


OUT1 OUT2 OUT3 OUT4
1.......................................................................................... 2.......................................................................................... 3.......................................................................................... 4..........................................................................................

Ph

230V N 50Hz

9 modules

Each output: 0-10Vdc or 1-10vdc Max Current 5ma

DIMMER ANA04

BUS A1 A2

BUS A1 A2

14

15

HabiTEQTM
Input Modules

HabiTEQTM
INP08/230
There are 8 optically insulated inputs. Each input needs a voltage to be active. This can be: 12Vac/dc if connected between B and C (consumption approximately 10mA) 230Vac if connected between A and C (consumption approximately 1W) Orange LED lights positioned near inputs 1-8 indicate if input is active. If there are inputs with potential-free contacts they can be connected to the module via 12Vac. The required voltage is provided on the top and bottom sides of the module.
1A

L 16A 230VAC 50Hz N

Input Modules
Choice of ve different input modules are available in the HabiTEQ to connect external contacts such as solar/wind detector, movement detector, door switches, push-buttons and analogue sensors. 8/16 optical isolated inputs are provided, which must be potential-free. The input contacts can be selected and set using the PC software: Push-button = button that is open when inactive (e.g. doorbell) Normal open = contact that is open when inactive Normal closed = contact that is closed when inactive Switch = single-pole conventional switch. The maximum length of each input is 200 m. The cable type is irrelevant as long as the 2 wires are each 1mm2. (Contact load 1mA) Each of the 4 inputs has a unique serial number. (E.g. So INP08 has 2 serial numbers and INP16 has 4 serial numbers). The common (1st connector on the right top and bottom) is connected internally. One may connect these together with other INP16 modules.

230VAC

230VAC

12V

1B

1C

2A

2B

2C

3A

3B

3C

4A

4B

4C

NC 12Vac Output max 100 ma

Ph NC N 230V/1.5VA

INPUTMODULE INP08/230

INPUT: XA-XB=max 230Vac/1W XB-XC=mas 12Vac/dc/10ma NC= not connected

5A

5B

5C

6A

6B

6C

7A

7B

7C

8A

8B

8C

NC 12Vac Output max 100 ma

BUS BUS A1 A2 A1 A2

INPA04
General specications :
Power supply : 230Vac +-10%, 50 Hz - maximum protection 6A/2P Insulation voltage : 3 kV tested Characteristic consumption : 2,8VA Bus load : 10mA at nominal 13,8V Internal fuse : 500mA single-phase Max installation altitude : 2.000m
L 16A N 230VAC 50Hz P100 or P100 P1000 P1000

Always use potential-free contacts! never connect or disconnect modules while the bus is energized!

Inputs : PT1 PT4 : 4 temperature sensors type Pt100 or Pt1000 ANA1 ANA4 : 4 analogue input signals 0-10V

FUSE 0,5A

Ph N 230 V

B
PT3

PT1

PT2

ANA1-ANA4 Analogue 0-10V PTI-PT4 PT100... or PT100


PT1

A B C D
ANA2 + _

INPUT AN104

ANA1 + _

ANA3 + _

ANA4 + _

BUS2 BUS2 A1 A2 A1 A2

Led indication : Green light (right): bus power Green light (middle): mains power Red light: data transfer + error LED

10V DC Use only one at a time, either 12Vac or 230Vac

INP04
This module can be used to interface with any conventional switch to the bus. The size of the module permits installation within the switch enclosure.

INPUTMODULE INP04
INPUT CONTACTS POTENTIAL FREE LEDS

Product description Module for DIN-rail, suitable for controlling four analogue input signals. The input signals can be four Pt100 - Pt1000 temperature sensors or four analog input signals 0-10V. The temperature sensors are to be connected to terminals PT1 till PT4. One can use a four wire connection or a two wire connection. When using a two wire connection terminals A-B and C-D should be short-circuited. Input terminals ANA1 till ANA4 are used for importing any analog signal from 0-10V.
INPUT MODULES INP04 INP08

C IN1 IN2 IN3 IN4

V+ L1

L2

L3

L4

Remark: There is no possibility to have simultaneously a temperature reading at PT1 and an analogue signal on ANA1. If PT1 is used ANA1 is no longer available and vice versa. Although a combination of for instance a PT1 and an ANA2 is possible. Each module has a unique serial number enabling programming anywhere and anytime. All programming remains internally stored in a nonvolatile memory. After a voltage cut-off, the outputs return to their latest position. A bipolar automatic fuse of a maximum of 16A must be placed on the mains power.
INP16 230Vac/50..60Hz INP08/230 INPA04 analogue input module 10mA at 13.8V 2.8VA 3kV DIN rail

BUS

Digital input module


Only IN1 to IN8 operational for INP08 16A N 230VAC 50Hz L

Power supply Bus load Characteristic consumption Insulation voltage Fitting 20mA at 13.8V 2.3VA@230Vac Typically inside conventional switch enclosure on wall Inputs

INP08/INP16
C IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8
C
ANA1 ANA2 ANA3 ANA4 Ph NC 230V 50HZ N

IN1..IN16: potential free Optional: ANA1..ANA8: analogue IN 0-10V C= common NC= Not connected
C IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16

INPUT INP 08/16

There are 8 or 16 optically insulated inputs. Each input needs a voltage to be active. This can be 12Vac/dc if connected between B and C (consumption approximately 10mA) If there are inputs with potential-free contacts they can be connected to the module via 12Vac. The required voltage is provided on the top and bottom sides of the module.
Number

BUS C ANA5 ANA6 ANA7 ANA8 A1

BUS A2 A1 A2

4 potential-free inputs

"8 potential-free inputs

16 potential-free inputs

8 (12Vac/dc or 230Vac selectable by connection)

4 analogue inputs or 4 anologue outputs

Input function (Congurable through software serial manager) LED indication Dimensions

Pusht button = button that is open when inactive (e.g. doorbell). Normal open = contact that is open when inactive. Normal closed = contact that is closed when inactive. Switch = single-pole conventional switch. Green light : power supply Red light : Start-up 2 s, and during programming 32x37x12mm 6 modules 9 modules

Can be congured by SW :1. PT100,PT1000 or 2. 0-10V input Green light : power supply. 6 modules

16

17

HabiTEQTM
Communication Interfaces
Communication can be established through PC via an Ethernet connection or through a serial adapter for programming the system. Further control of the HabiTEQ can also be done through a mobile phone using basic pre-congured SMS messages. Communication Interfaces

HabiTEQTM
Mobile Interface Module
The SMS01 is a DIN mounted module that can be installed within the HabiTEQ. The power supply is 230Vac. If the module must work when power drops, a UPS or internal rechargeable battery (Li-Ion) needs to be installed optionally. A connection (230V or 12V) is available in order to be able to send a message when the power drops. The SIM card must be inserted on top of the module into the SIM card reader. If the module is mounted in a metal distribution box or on a place with bad network coverage (cellar, concrete....) it is recommended to add an optional antenna. Features: Maximum 8 phone numbers (+1 emergency number) can get access to the system View and control outputs: max 96 channels (sequences included) can be activated - Conrmation to selectable numbers - Comparison SMS texts with more than 1 user dened texts e.g. KITCHEN ON or KTC ON - Different value denitions (e.g. ON- OFF - 0 - 1 - 50%...) Alarm messages: - Maximum 16 different alarm messages (e.g. burglar alarm, re, power down etc.) can be sent to up to 8 + 1 phone numbers with intervals selectable from 1min. 10min.) and repeat rate 1-5 for each SMS can be set. - Stop sending alarm texts when SMS - STOP message is received. - Warning power down to all Numbers
L 16A N 230VAC 50Hz

FUSE 1 AT

PH
230Vac 2.3VA

SMS MODULE SMS01

Powercontrol:
11 12 C

11-C=230Vac 12-C=12Vac
BUS BUS A1 A2 A1 A2

Ethernet/WEB interface
The Ethernet interface module for DIN rail allows the HabiTEQ system to communicate with a PC or network. The module can be connected to the bus in any location and be linked to a network card of the PC, hub, Switch or router via an RJ-45 connector. The supplied software allows programming and operating of the installation. Multiple modules can be positioned on the bus. This interface has a built-in web server for the on-line operation of a control table (96 channels and 6 menus) via any Internet browser. Protocol details to control the HabiTEQ system via TCP/IP or interface to higher end BMS system can be provided on request.

L 16A N 230VAC 50Hz

Power Fail signal

Ph

230V 50Hz

ETHERNET INTERFACE ETH02

12Vac Use only one at a time , either 12Vac or 230Vac. 230Vac

10/100 BASE-T ETHERNET MAC address


BUS BUS A1 A2 A1 A2

TCP/IP

SER02

Serial interface
When the interface SER02 (external module) is connected on a router to the Internet, it is possible to use all features from anywhere in the world. The serial interface allows the HabiTEQ system to communicate with a PC or a modem. The module can be connected to the bus in any location and be linked to the PCs COM port via a SUB-D9 connector. The supplied free SERIAL MANAGER II software allows programming and operating the installation. Connection to the USB port of a PC or laptop occurs via the USB Serial Cable Interface (USB01). The rst serial interface in the installation has been pre-programmed on ADDRESS 02. Multiple serial modules can be positioned on the bus subject to the specication of the desired address when ordering.
COMMUNICATION INTERFACES Power supply Max. protection needed Bus load Internal fuse Characteristic consumption Insulation voltage Fitting DIN rail Connections - RJ-45 connector for connection to network - Grey FTP crossed over cable : direct connection between PC and ethernet interface. - Yellow UTP cable : connection via router, switch, hub Green light : power supply LED indication

BUS

DLL to communicate with all features of the system, is available as freeware: The software when installed on the PC and connected to the HabiTEQ allows performing the following: Initializing the controller (assign outputs, switching behavior, timer, parameters, shutters, dimmers, etc.) Addressing of input and output modules Creating sequences Setting switching times Constructing logical functions
ETH02 Ethernet interface 230Vac/50..60 Hz 16A/2P 10mA at 13.8V 100mA 2VA 3kV Wall mounting SER02 Serial interface Supplied by the bus 15mA -

Note: Pincode cant be enabled or disabled when the SIM card is in the module. Pincode authentication of the SIM card needs to be removed with normal phone before placing it in the module.

MOBILE INTERFACE Power supply Power guard connection Bus load Characteristic consumption Internal fuse Insulation voltage Outputs Access and agenda phone numbers Control possibilities Alarm messages Pincode

SMS01 SMS MODULE AC 230V, 50..60Hz - maximum


Power guard inputs: Connection I1 C : 230Vac max 1VA Connection I2 C : 12Vac max 1VA

10mA at 13.8Vdc 2.3VA 1AT 3kV Up to 96 outputs (including sequences) can be activated or viewed Max. 8 phone numbers (+1 emergency number) can get access to the system SMS texts can have different dened texts for different users and different status denition Max.16 alarm messages can be sent to all numbers Warning power down to all numbers if battery is connected possibility of enable / disable Not included In built antenna on top and optional external antenna Tri-band 6 modules

Type

Connects serial SUB-D9 connector to Qbus

SIM card Antenna Band width Dimensions

Green light : power supply

Red light : start-up 2s and during programming Communication

Protocol Speed Visualization & Control Dimensions

TCP/IP with an integrated webserver Built-in web server / Control upto 96 channels and 6 menus via any Internet browser. 6 modules

Baud rate 19200bits/s Through serial manager software 75x75mm built in frame

General specications for all automation modules


Operating temperature Storage temperature Maximum humidity Protection degree Fitting 10 to 50C without condensation -10 to 60C without condensation 93%, no moisture condensation IP20, EN 60529 DIN rail to DIN EN 50022

18

19

GE Consumer & Industrial Power Protection

Do you want to learn more about HabiTEQTM?


Please contact your installer or distributor. Hes the right person to answer all your questions about GE products and home automation systems.

www.ge.com/ex/powerprotection

ecomagination

SM

GEs company-wide commitment to help customers and consumers meet environmental challenges

GE CONSUMER & INDUSTRIAL POWER PROTECTION Nieuwevaart 51 B-9000 Gent - Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 00 E-mail: gepcbel@gepc.ge.com Customer service Tel. 0800/74410 fax 0800/75200 e-mail: klantenservice.be.consind@ge.com

GE CONSUMER & INDUSTRIAL HUNGARY Vci t 77 H-1340 Budapest Hungary Customer service Tel. +361 447 6046 Fax +361 447 5060 e-mail: mea.export .consind@ge.com www.gepowershop.com

Your local salesman or contact information

GE imagination at work
Ref. R/2371/E/X 1.0 Ed. 09/09 Copyright GE Consumer & Industrial 2009