You are on page 1of 26

Formerly A. O.

Smith Electrical Products Company

Farm Rated Motors


1401C

A Regal Brand

Farm Rated Motor Cross Reference

Century
Cat. no.
486A
647A
648A
914L
915L
9451A
9452A
970A
B221
B221
B587
B592
C042A
C043A
C044A
C045A
C046A
C047A
C048
C310
C310C
C311
C311C
C312
C312C
C313
C313C
C314
C314C
C317V1
C319
C330
C331
C332
C333
C337
C338
C339
C340
C340
C580
C581
C582
C588
F500L
F501
F683
K102
K103,K104
K116
K117
K118
K204/K213
K205/K214
K208/K215
K213
K214
K220
K221
K236
K300
K301
K302
K311
K312
K321
PD6104AV3
PD6104V2
R243
R244
R327
V209
V303
V305

Baldor

WeG

YPC164A

YPC264A

YPC244A





YPC144A

YPC344A

YPC244A

AFL3520A

CHC3528A





CHC3413A

CHC3416A
.3318ES1BRBPFC4
CHC3524A
.5018ES1BRBPFC56
CHC3414A

CHC3417A

CHC3525A

CHC3526A

FDL3501M
.3318ES1RFDB56
CFDL3501M

FDL3504M
.5018ES1RFDB56
CFDL3504M

FDL3507M
.7518ES1RFDB56
CFDL3507M

FDL3510M
00118ES1RFDDB56
CFDL3510M

FDL3514TM
00158ES1RFDF56H
CFDL3514M

GSL3509M

FDL3516TM
00218ES1RFDF145T
ANFL3501M
.3318ES1RADB56N
ANFL3504M
.5018ES1RADB56N
ANFL3507M
.7518ES1RADB56N
ANFL3510M
00118ES1RADD56N


IR3507M

IR3510M



ANFL3514M
00118ES1RADD56N












CHC3417A

FDL3510TM
00118ES1RFD143T
FDL3514M
00158ES1RFD145T
AFL3524A

AFL3522A

AFL3523A

FDL3611TM
00218ES1RFD182T
FDL3619TM
00318ES1DFD184T
FDL3612TM
00518ES1DFD184T
FDL3611TM
00218ESR1RFD182T
FDL3610TM
00318ES1DFD184T
UCL570

UCL710



FDL3731M
00518ES1DFD215T
FDL3732M
00718ES1DFD215TZ
FDL3737TM
01018ES1DFD215T
L3710T
00718ES1DFD215T
L3712T

UCL710

AFL3521A


0118ES1BRBPFD56
UCM713

UCM575

UCM1014/UCME1014
L1410T

GDL1610T

GDL1607T

dayton

nideC/uSeM

4M196




4M254
4M256
4M255
4K058



1YAZ4
1YAZ5
1YAZ6




ITMY2
1TMW3
ITMY3
1TMW5
1TMY4
1TMW7
1TMY5
1TMW9
ITMY6
1TMX2
1TMY6
ITMW1
3K994
3K995
3K996
4K121




2K351







1TMV9
ITMX5



1TMX6
ITMX8
1TMY7
1TMV8
1TMV2
1YBV2
1YBV3

ITMV4
1TMV5
1TMV6
1TMY8
1TMY9
1YBV4















FD34CA1PZ










FD13CM2P

FD12CM2P

FD34CM2P

FD1CM2PZ

FD32CM2PZ


FD2CM2PHZ
FD138M2PZYR
FD12CM2PZYR
FD34CMP2PZYR
8838




FD32CM2PHZY







FD1CM2P14
FD32CM2P14
FD3CA1K14
FD32CA1P14
FD2CA1P14
FD2CM2P18
FD3CM2K18
FD5CM2K18
FDU2CM2P18Z
FDU3CM2K18
FDCM1K18Z
FDCM1K18Z

FDU5CM2K21Z
FDU7CM2K21Z
FDU10CM2K21
FD7CM2K21


FD1CA1PZ






Marathon
X923
X924
X925


X920
X922
X921
C1467



H649/X024/X030
H648/X025/X031
H647/X026/X032
X027
X028
X029

F101

F102

F103

F104

F105

X902
Z128
C1291
C1292
C1293
C1294




C1295
X913


X912
X904
X900
X028
Z123
Z118
C1275
C1273
C1274
Z112
Z113
Z121
Z119
Z120
Z305
Z307

Z117
Z115
Z116
Z122

Z308


Y303
Y302
Y304
Z124
Z126
Z125

leeSon
191891.00
191892.00
191912.00
191872.00
191875.00
191872.00
191873.00
191671.00
111332.00
111322.00
113939.00
113939.00
100803.00
100804.00
111323.00
100824.00
100825.00
111321.00
111919.00
113256.00
116485.00
110086.00
116486.00
110087.00
116487.00
110088.00
116488.00
110089.00
116489.00
111330.00
110090.00
101435.00
101436.00
101437.00
113302.00
114932.00
114932.00
114933.00
113280.00
113301.00/113301.00
M009580.00
M009581.00
M009782.00

100825.00
121569.00
113938.00
120376.00
120374.00
120375.00
131541.00
131542.00
131543.00
131541.00
131542.00
131847.00
131848.00
101651.00
140203.00/140223.00
140209.00
140414.00
140707.00
140708.00
140640.00
111333.00
111267.00
131850.00
131849.00
140641.00
131537.00
140311.00
140155.00

For additional cross reference information go to www.centuryelectricmotor.com

TESTIMONIALS
Livestock and Poultry Farm
Stachler Farm has been using in excess
of 100 Century motors on his poultry
and cattle farm since 1993 without a
single replacement.
With coverage like that, Bill enjoys
more time with his family and friends
and occasionally a NASCAR race.
~ Bill Stachler
St. Henry, OH

Distributor of Farm Rated


Products
Century carries a wide range of farm
duty motors. We use a lot of the small
aeration fan motors and single phase
auger motors. The product they sell
is of very good quality. We have had
very few problems with the motors we
sell. If we do have a problem Century
does a good job of taking care of
it right away. I would recommend
Century to anyone looking for a good
quality farm duty motor.
~ Kevin Killingsworth
Fremont, NE

TESTED

PROVEN

RELIABLE

Table of Contents
Aeration Fan Motors

Single Phase Capacitor Start TEAO Rigid Base


Three Phase TEAO Rigid Base......................................................................................................1

Single Phase ODP Rigid Base


Three Phase ODP Rigid Base
Single Phase OEM Replacement Capacitor Start ODP Rigid Base.....................................2

Single Phase Capacitor Start Three Phase TEFC/TENV No Base.........................................3

Single Phase Three Phase ODP Rigid Base............................................................................3

Single Phase Capacitor Start Single Speed TEAO Rigid Base


Single Phase Capacitor Start Two Speed TEAO Rigid Base................................................4

Single Phase Permanent Split Capacitor OAO Rigid Base


Single Phase Permanent Split Capacitor TEAO Rigid Base
ThreePhase TEAO Rigid Base..................................................................................................4

Single Phase Split Phase TEAO Resilient Base


Single Phase Capacitor Start TEAO Resilient and Rigid Base................................................5

Single Phase Permanent Split Capacitor TEAO Resilient Base


Single Phase Permanent Split Capacitor OAO/TEAO Resilient and Rigid Base
Single Phase Split Phase OAO No Base
Single Phase Permanent Split Capacitor TEAO Rigid Base....................................................6

Single Phase Capacitor Start TEFC Rigid Base


Single Phase Capacitor Start TEFC Rigid Base C-Face
Single Phase High Torque TEFC Rigid Base...........................................................................7
Single Phase Extra High Torque TEFC Rigid Base
Single Phase Extra High Torque TEFC Rigid Base C-Face...................................................8

Single Phase Capacitor Start TEFC Rigid Base.......................................................................9

Single Phase Capacitor Start Solid State Switch TEFC Rigid Base......................................9

Single Phase Permanent Split Capacitor Three Phase TENV Rigid Base
PMDC 95-Volt Zero Tank Replacement TENV No Base....................................................10

Single Phase Permanent Split Capacitor/Split Phase TE/ODP Yoke Mount..........................11

Single Phase ODP Rigid Base


Single Phase ODP C-Face End Bracket
Single Phase TEFC C-Face End Bracket..................................................................................13

Three Phase TENV/TEFC Rigid Base........................................................................................14


PMDC 90/180-Volt TEFC Removable Rigid Base.................................................................14
Three Phase Paint Free TENV No Base................................................................................14

Single and Three Phase 143T-449T..............................................................................................15

Air Compressor Motors

Auger Drive Feed Line Motors


Centrifugal Fan Motors
Cow Cooler Motors
Crop Dryer Motors

Farm Building Belted Ventilation Motors

Farm Building Direct Drive Ventilation Fan Motors

Farm Rated Motors

Grain Stirring Motors

Instant Reverse Motors


Milk Pump Motors

Pedestal Fan Motors

Poultry Duty Motors


Single Phase TEAO Rigid/Resilient Base.................................................................................12
Pressure Washer Motors

Three Phase Motors

General Purpose IHP Motor Dimensions

NEMA Frame Assignments..................................................................................................16


Pulley Speed Chart ................................................................................................................17
Statement of Warranty Policy. ................................................................Inside Back Cover

Aeration Fan Motors by Century


Fan Duty Only Single & Three Phase Totally-Enclosed Air-Over
Rigid Base 3600 RPM 1/2 thru 3-4 HP
Features: Ball Bearings Class B Insulation 60 Hz Service Factor 1.0 40C Ambient Reversible
Applications: Direct replacement for many OEM models.


HP


RPM

B221


Volts

Full Load
Amps


Frame

Stock
Number


Wt.

Shaft Diameter
and Length

Overload
Protector

C
Dim.

115/230
115/230
115/230
115/230
230
230
230
230

6.4/3.2
5.8/2.9
8.0/4.0
9.2/4.6
6.5
8.4
12.4-17.0
15.4

48Z
56
56
56
143T
145T
145T
145T

B666
B220
B221
B222
K117
K118
K112
K116

20
22
28
31
34
36
39
44

1/2 x 2
5/8 x 1-7/8
5/8 x 1-7/8
5/8 x 1-7/8
7/8 x 2-1/4
7/8 x 2-1/4
7/8 x 2-1/4
7/8 x 2-1/4

Auto
Auto
Auto
Auto
Auto
Auto
Thermostat
Thermostat

10.4
11.1
11.4
12.2
12.6
13.1
13.8
13.8

14,45
70
70
70
70,182
70,182
5,116,182,$
70,116,182

208-230/460
208-230/460
208-230/460
208-230/460
230/460

2.6-2.4/1.2
2.8-2.7/1.35
4.4-4.2/2.1
7.1-6.8/3.4
8.4/4.2

56
56
143T
145T
145T

H041
H042
R180
R181
R155

24
28
31
35
34

5/8 x 1-7/8
5/8 x 1-7/8
7/8 x 2-1/4
7/8 x 2-1/4
7/8 x 2-1/4

None
None
Thermostat
Thermostat
Thermostat

11.1
11.1
12.1
12.1
12.1

116,182
116,182
116,177,182

Notes

Single Phase
12
12
34
1
1-12
2
3-4
3

3600
3600
3600
3600
3600
3600
3600
3600

Three Phase




34
1
1-12
2
3-4

3600
3600
3600
3600
3600

Notes:
5.

14.
45.
70.
116.

177.

182.

$ Energy efficient two value capacitor start


capacitor run motor
Totally enclosed, non-ventilated
Capacitor start
Permanent split capacitor
Temperature sensitive thermostat with
two leads for connection to external control
Meets the requirements of the
Energy Policy Act of 1992
Locked bearing on drive end

www.centuryelectricmotor.com

Aeration Fan Motors by Century

Air Compressor Motors by Century


OEMSpecial Replacements Dripproof Rigid Base Single Phase
Capacitor Start/Capacitor Run
Features:

B385

Non-ReversibleConnected for CW Facing End Opposite Shaft Energy Efficient $ 60 HZ 40C Ambient Class B Insulation Manual Protector





HP
2 SPL
3 SPL
5 SPL


RPM
3600
3600
3600


Volts
115/230
115/230
208-230

Full Load
Amps
15.0/7.5
15.0/7.5
15.0

Service
Factor
1.0
1.0
1.0


Frame
56
56
56

Stock
Number
B381
B383
B385


Wt.
27
30
37

Sears
Part Number


C
Dim.
11.3
11.6
12.6

Notes
$
$
$

Air Compressor Motors by Century

Rigid Base 3600 & 1800 RPM 1/2 thru 6 HP Single Phase
Features:

Ball Bearings
Continuous Duty

60 Hz
Rigid Base

Class B or F Insulation
Open Construction

40C Ambient
CP1152L

B813

Applications: Designed for air compressor loads. May be suitable for other applications having similar loads.


HP
12
34
1
1-12
2
3


5
5
5
5
5


6
SPL


RPM
3600
3600
3600
3600
3600
3600
1800
3600
3600
3600
3600
3600
1800
3600
3450


Volts
115/230
115/230
115/230
115/230
115/230
208/230
115/230
230
230
208-230
208-230
230
230
230
230

Full Load
Amps
9.6/4.8
12.5/6.75
12.0/6.0
12.5/6.3
22.2/11.1
13.1/12.3
34.0/17.0
19.7
22.0
22.0
22.0
25.6
22.0
24.0
15.0

Service
Factor
1.00
1.00
1.00
1.00
1.00
1.00
1.15
1.00
1.00
1.15
1.15
1.15
1.15
1.00
1.00


Frame
56
56
56
56
56
56
184T
56HZ
56HZ
56HZ
56Y
184T
184T
56Y
56H

Stock
Number
B685
CP1072L
CP1102L
CP1152L
CP1202L
CP1302L
V201
CP1502L
B813
B386
B384
V211
V208
B387
CP1502LV1

Notes:

Overload
Protector
Manual
Manual
Manual
Manual
Manual
Manual
None
Manual
Manual
Manual
Manual
None
None
Manual
Manual


Rotation
CWLE
REV
REV
REV
REV
REV
REV
REV
CWLE
CWLE
CWLE
REV
REV
CWLE
REV


Wt.
18
24
26
32
32
33
78
44
45
37
50
82
84
53
37

C
Dim
Efficiency
Notes
11.0

233
10.6

233
11.4

233
11.9

85,$,233
12.7

233
12.7

85,$,233
14.7
77.0
233
14.1

15,85,$,233
14.1

85,$,233
14.6

85,$,233
14.6 85,97,320,$,233
14.7
77.0
233
15.0
82.0
85,$,87
14.6 85,97,298,$,233
12.8

85,180,$,233

15. 56HZ = 7/8 x 2-1/4 Shaft


85. Energy efficient $ - capacitor start/run
87. Class F insulation
97. 182T and 184T mounting holes, 4.5 shaft height
180. Low AMP replacement for a variety of O.E.M. Special and SPL 5
horsepower requirements
233. Class B insulation
298. 2-1/4 x 7/8 keyed shaft
320. 56Y = 7/8 diameter keyed shaft, 2.25 long

www.centuryelectricmotor.com

Auger Drive Feed Line Motors by Century


Direct Drive Capacitor Start Totally Enclosed Fan Cooled
No Base 1800 RPM 1/3 thru 1-1/2 HP
Features:

Three Phase

New N Flange Bracket

High Starting Torque

Torque Switch and Governor

Service Factor 1.0

Reversible

Double Sealed Ball Bearing

Manual Reset

Class B Insulation

60 Hz

C332

40C Ambient

Applications: Designed for direct drive poultry and swine auger feeding systems.


RPM


Volts

Full Load
Amps

115/230
115/230
230/115
230/115
230/115

5.5/2.8
7.2/3.6
5.2/10.4
6.0/12.0
6.6/13.2


Stock
Frame Number

Base/
Mounting


Enclosure

Shaft Dia.
& Length

Insulation Overload

Class
Protector Rotation

C
Dim Notes

Single Phase
13
12
34
1
1 12

1725
1725
1725
1725
1725

56N
56N
56N
56N
56N

C330
C331
C332
C333
C340

Round
Round
Round
Round
Round

Frame
Frame
Frame
Frame
Frame

TENV
TEFC
TEFC
TEFC
TEFC

12 x 1-3/4
12 x 1-3/4
12 x 1-3/4
58 x 2.10
58 x 2.10

B
B
B
B
B

Manual
Manual
Manual
Manual
Manual

RCC
RCC
RCC
RCC
RCW

9.6
12.4
12.4
13.3
14.5

56N
56N
56N
56N
56N

C345
C346
C347
C348
C349

Round
Round
Round
Round
Round

Frame
Frame
Frame
Frame
Frame

TENV
TEFC
TEFC
TEFC
TEFC

12 x 1-3/4


1/2x 1-3/4

B
B
B
B
B

Manual
Manual
Manual
Manual
Manual

RCC
RCC
RCC
RCC
RCC

9


11.41

Three Phase
13
12
34
1
1 12

1725
1725
1725
1725
1725

200-230/460 1.2-1.2/.06
200-230/460

200-230/460

200-230/460 3.1-3.0/1.5
200-230/460

NEW!
NEW!
NEW!
NEW!
NEW!

Centrifugal Fan Motors by Century

Single & Three Phase Dripproof Rigid Base 1800 RPM 5 thru 30 HP
Features:

Ball Bearings
60 Hz

Class B or F Insulation
Reversible

40C Ambient
Service Factor 1.15

E457

Applications: Centrifugal fans and blowers, barn coolers, poultry house coolers, livestock and poultry house temperature control.



HP
RPM
Volts

Full Load
Amps
Frame

Single Phase Capacitor Start Capacitor Run




5
7 12
10

1745
1750
1750

230
230/460
230/460

22.0
32.0/16.0
38.0/19.0

184T
215T
215T

5
7 12
10
15
20
25
30

1760
1760
1755
1770
1765
1765
1765

230/460
230/460
230/460
230/460
230/460
230/460
230/460

13.6/6.8
19.4/9.7
25.2/12.6
37.8/18.9
49.0/24.5
61.0/30.5
73.2/36.6

184T
213T
215T
254T
256T
284T
286T

Three Phase

Stock
Number
Type

Shaft Dia.
& Length

V209
V305

V303

1-1/8 x 2-7/8
1-3/8 x 3-1/2
1-3/8 x 3-1/2

F
B
F

REV
REV
REV

15.0
17.3
17.9

82.0
86.0
86.5

1-1/8 x 2-3/4
1-3/8 x 3-3/8
1-3/8 x 3-3/8
1-5/8 x 4
1-5/8 x 3-3/4
1-7/8 x 4-3/8
1-7/8 x 4-3/8

F
F
F
F
F
F
F

CCW
CCW
CCW
CCW
CCW
CCW
CCW

13.7
17.5
17.3
22.1
22.1
24.3
25.8

89.5
91.7
91.7
93.0
93.6
93.6
94.1

E219 J
E317 J
E397 J
E451 J
E407 J
E514 J
E516V2 J

E+3(NP)
E+3(NP)
E+3(NP)
E+3(NP)
E+3(NP)
E+3(NP)
E+3(NP)

Insulation
Class
Rotation

C
Dim. Efficiency Notes
5,$
5,80,$
5,80,$

8
8
23
23

Notes:

$ Energy Efficient $
5. $ Energy efficient two value capacitor start, capacitor run motor
8. NEMA design A
23. Suitable for 200/400 volt and 50 HZ
80. Large capacitor/terminal box construction
Published efficiency on tri-voltage rated motors
applies at 230/460 volts.
Performance at 200 or 208 volts may not be in
accordance with NEMA standards.

www.centuryelectricmotor.com

Motors specially designed, tested and warranted


to be Corona-Free for compatible inverter duty
are marked on this page with a J.

Auger Drive & Centrifugal Fan Motors by Century


HP

Cow Cooler Motors by Century


Features:

Rigid Base
Service Factor 1.0
Single Phase
Totally Enclosed, Air Over
1 thru 1.5 / .44 HP

Ball Bearings
Capacitor Start Capacitor Run
Class B Insulation
Low Starting Torque
Reversible

40C Ambient
60 Hz
1800 & 1800/1200 RPM
Energy Efficient $

C594

Applications: Environments requiring air movement.



HP


RPM


Volts

Full Load
Amps


Frame

Stock
Number


Wt.

Overload
Protector

C
Dim.

Notes

1800
1800

115/230
115/230

9.6/4.8
17.0/8.5

56H
56H

C593
C594

38
38

Manual
Manual

12.69
12.69

$
$

1800/1200
1800/1200
1800/1200
1800/1200

115
230
115
230

11.4/6.4
5.3/3.0
15.6/9.1
7.4/4.4

56H
56H
56H
56H

C596
C597
C595
C598

35
35
43
45

Manual
Manual
Manual
Manual

12.69
12.19
13.94
13.19

181,$
181,$
181,$
181,$

Crop Dryer & Cow Cooler Motors by Century

Single Speed
1
1-12

Two Speed
1.0~.29
1.0~.29
1.5~.44
1.5~.44
Notes:
31. 40 degree C ambient
181. Loose lead construction

Crop Dryer Motors by Century


Direct Drive Only Single & Three Phase Dripproof Air-Over & Totally
Enclosed Air-Over Rigid Base 3600 & 1800 RPM 5-7 thru 10-14 HP
Features:

Ball Bearings
60 Hz
50C Ambient

Class F Insulation
Service Factor 1.0
Reversible

Winding Thermostats
Moisture Resistant
Rust-Resistant Rotor

Switchless Design
Long Leads
Copper Wire Wound
Shaft Drilled & Tapped in End

K220

Applications: For tubeaxial and vaneaxial direct drive dryers.



HP


RPM


Volts

Full Load
Amps


Frame

Stock
Number


Wt.

Shaft Diameter
and Length

C
Dim.

Efficiency

84
91
125
146
138

1-1/8 x 4-1/2
1-1/8 x 4-1/2
1-1/8 x 4-1/2
1-3/8 x 5-1/2
1-1/8 x 4-1/2

17.9
18.8
19.9
21.9
20.9

81.0
82.0
84.4
83.0
86.5

Notes

Single Phase Permanent Split Capacitor Open Dripproof Air-Over


5-7
7-10.5
7.5-10.5
10-12
10-14

3600
3600
3600
1800
3600

200-230
200-230
200-230
230
200-230

32.0-28.0
48.0-41.0
43.0-38.0
40.0-48.0
57.0-52.0

184TZ
184TZ
215TZ
215TZ
215TZ

K220
K221
K320
K327
K321

31

Single Phase Permanent Split Capacitor Totally Enclosed Air-Over


7-10.5

3600

200-230

45.0-40.0

184TZ

K236

118

1-1/8 x 4-1/2

21.0

83.5

184TZ
184TZ
215TZ

R244
R243
R327

75
70
109

1-1/8 x 4-1/2
1-1/8 x 4-1/2
1-1/8 x 4-1/2

17.1
20.0
20.0

84.0
84.0
88.0

Three Phase Totally Enclosed Air-Over


5-7
7-10.5
10-14

3600
3600
3600

208-230/460
208-230/460
230/460

19.0-17.0/8.5
27.0-25.0/12.5
36.0/18.0

www.centuryelectricmotor.com

Farm Building Belted Ventilation Motors by Century


Features:

Automatic Reset Overload Protector


Class B Insulation
Resilient & Rigid Base
Double Sealed Ball Bearings
Extended Thru-Bolts 34 Past Nut
Reversible

Single Phase
Split Phase & Capacitor
Start Capacitor Run
Totally Enclosed Air Over
1/3 thru 1 HP
Service Factor 1.0

1800 RPM
Energy Efficient $
40C Ambient
60 Hz
C580

Applications: Designed for dirty environments such as poultry houses, barns, etc. fan & belted fan only.


HP


RPM


Volts

Full Load
Amps


Frame

Stock
Number


Wt.


Base

C
Dim.

1800
1800
1800

230/115
230/115
230/115

2.2/4.4
3.5/7.0
3.5/7.0

48Z
56Z
56

F500L
F501
F502

13
24
25

Cushion
Cushion
Cushion

11.21
11.07
11.07

141
141

6.4/3.2
3.2/6.4
3.6/7.2
4.8/9.6
4.3/8.6
4.3/8.6//5.2/10.4

56
56
56
56
56
56

C588
C580
C581
C582
C782
C782RB

33
30
35
39
39

Cushion
Rigid
Rigid
Rigid
Rigid
Removable

11.44
11.44
11.94
12.44
12.19
12.20

$
$
$
$
1,312,$
6,$ New!

Notes

SPLIT PHASE
1/3
1/2
1/2

Farm Building Belted Motors by Century

CAPACITOR START CAPACITOR RUN







1/2
1/2
3/4
1
1
1

1800
1800
1800
1800
1800
1725/1425

115/230
230/115
230/115
230/115
230/115
230/115

Notes:
1. Item to be discontinued when stock is depleted
141. Shaft diameter is 1/2, N=1.94 with .04 deep flat 1.88 long
312. 1.40 Service Factor

www.centuryelectricmotor.com

Farm Building Direct Drive Ventilation Fan Motors by Century


Features:

Auto Protector
Class B Insulation
Direct Drive
Double Sealed Ball B earings
Extended 10-32 Thru-bolts 3/4 Past Nut
Fully Gasketed

Reversible
Service Factor 1.0
Single Phase
60 Hz
40C Ambient
Totally Enclosed, Air Over

C783

C048

C039A
C042A
C043A
C044A
C045A

Farm Building Direct Drive Fan Motors by Century

Applications: Designed for farm air movement applications.


F683, F684


HP

resilient base

C046A
C047A
C059
C059A


RPM


Speeds


Volts

Full Load
Amps


Frame

Stock
Number


Wt.


Shaft

C
Dim.

Notes

1/4
1/4
1/4
1/3
1/3
1/2
1/2
1/2
1/2

1700
1100
1100
1725
1100
1700
1100
900
900

1
1
2
1
1
1
1
1
1

115/230
115/230
115
115/230
115/230
115/230
115/230
115/230
115/230

3.4/1.7
4.0/2.0
3.4
3.6/1.8
4.2/2.3
5.5/2.8
6.5/3.25
7.1/3.6
6.6/3.3

48Z
48Z
48Z
48Z
48Z
48Z
48Z
48Z
56Z

C042A
C045A
C059A
C043A
C046A
C044A
C047A
C039A
C048

19
16
17
20
18
24
23
21
33

1/2 x 3-1/8
1/2 x 3-1/4
1/2 x 3
1/2 x 3-1/8
1/2 x 3-1/4
1/2 x 3
1/2 x 3-1/8
1/2 x 2-1/2
5/8 x 2-1/2

10.1
9.3
10.1
10.1
10.0
11.0
11.1
11.0
12.1

70,132,133
70,132,133
70
70,132,133
70,132,133
70,132,133
70,132,133
70,132,133
70,134

1/3
1/3

1800
1800/900

1
2

115
115

4.8
5.5/3.1

56Z
56Y

F683
F684

25
27

12 x 2
12 x 2

11.12
11.12

62
62

900

230

5.1

56CZ

C783

44

58 x 3-14

14.22

6,44,70

Thru Bolt Mount (10-32 UNF-2A)

Rigid Base
Notes:

6. 60/50 Hertz
44. CCWLE rotation only
62. Split Phase
70. Permanent Split Capacitor
132. Shaft sleeve and key supplied for 5/8 diameter
133. Shaft N-W = 2.50 with two flats .04 deep, 2.16 long, 90 apart
134. Shaft N-W = 2.50 with 58 diameter and keyway

www.centuryelectricmotor.com

Farm Rated Motors by Century


Single Phase Capacitor Start Totally-Enclosed Fan-Cooled
Rigid Base and Rigid Base with C-Face 1800 RPM 1/3 thru 2 HP
Features:

High Starting Torque


60 Hz

Ball Bearings
Reversible

Class B Insulation
40C Ambient
Bearings Lubricated with Low Temperature Grease

C312

Applications: Fans and blowers, feed lot conveyors, liquid manure spreaders, unloaders, compressors, storage bin conveyors.


RPM
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800


Volts
115/230
115/230
115/230
115/230
230/115
115/230
230/115
115/230
230/115
115/230
230

Full Load
Amps
5.2/2.6
5.2/2.6
7.2/3.6
7.2/3.6
5.2/10.4
10.4/5.2
6.0/12.0
12.0/6.0
7.5/15.0
15.0/7.5
9.0

Service
Factor
1.25
1.25
1.25
1.25
1.15
1.15
1.15
1.15
1.15
1.15
1.15


Frame
56
56C
56
56C
56
56C
56
56C
56
56C
56HZ

Stock
Number
C310
C310C
C311
C311C
C312
C312C
C313
C313C
C314
C314C
C319


Wt.
27
29
28
28
32
34
36
38
28
44
48

Overload
Protector
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual

C
Dim.
11.1
11.1
12.2
12.2
12.6
12.6
13.4
13.4
13.9
13.9
15.0

Notes
14
14

5 ,$
5,$
5,$

Capacitor Start Enclosed Rigid Base Motors


Industrial and Farm Duty Applications
Features:

Ball Bearing
Continuous Duty

Reversible
60 HZ

Capacitor Start
Energy Efficient $

40C Ambient
3450, 1725 & 1140 RPM
K100

Applications:

Compressors, conveyors, machine tools, pumps, air conditioning. Special service motors: air circulating fans, evaporative coolers, home workshops.



RPM
Volts
HP

12
3450
115/208-230
1/2
1725
115/208-230
1/2
1725
115/208-230
34

3450
208-230/115
3/4
1725
208-230/115
3/4
1725
208-230/115

1
3450
208-230/115

1
3450
208-230/115

1
1725
208-230/115

1
1725
208-230/115

1
1725
115/208-230
1-12
3450
208-230/115
1-1/2
1725
208-230/115
1-1/2
1725
208-230/115

2
3450
208-230/115
Notes:

Full Load
Amps
7.4/3.7-3.7
7.2/3.5-3.6
7.2/3.5-3.6
5.0-4.6/9.2
5.4-5.2/10.4
5.4-5.2/10.4
6.1-6.0/12.0
6.1-6.0/12.0
7.2-7.5/15.0
6.2-6.0/12.0
15.0/7.7-7.5
8.3-8.0/16.0
7.7-7.5/15.0
7.8-7.5/15.0
9.1-8.4/16.6

Service
Factor
Frame
1.15
56
1.15
56
1.15
56
1.15
56
1.15
56
1.15
56
1.15
56
1.15
56
1.15
56
1.15
56
1.15
143T
1.15
56
1.15
56H
1.15
56H
1.15
56H

Stock
Number
Wt.
B621
25
28
C612
C613
28
30
B664
C669
33
C671
33
33
B674
B695
32
34
C683
C685
37
K100
37
35
B762
C693
44
45
C686
40
B697

Overload
Protector
None
None
Auto
None
None
Auto
None
Manual
None
Auto
None
None
None
Auto
Manual

Approx.
C
11.2
12.2
12.2
12.2
12.6
12.6
12.2
12.2
13.4
13.4
13.7
12.7
13.9
13.9
14.4

Dim
AG
9.3
10.3
10.3
10.3
10.7
10.7
10.3
10.3
11.4
11.4
11.4
10.7
11.9
11.9
12.4

Enclosure
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC
TEFC

Notes
233
233
43
233
233
233
233
233
233
233
233
233
85,$,233
85,$,233
85,$,233

5. $ Energy Efficient two value capacitor start capacitor run motor


14. Totally enclosed non-ventilated
43. Class A insulation
85. Energy efficient $ - capacitor start/run full load amps listed at 60 Hz
233. Class B insulation

Shaft Dimensions
56 = 5/8 Keyed x 1-7/8
56H = 5/8 Keyed x 1-7/8
143T/145T = 7/8 Keyed x 2-1/4
182T/184T = 1-1/8 Keyed x 2-7/8
213T/215T = 1-3/8 Keyed x 3-1/2

www.centuryelectricmotor.com

Farm Rated Motors by Century


HP
13
13
12
12
34
34
1
1
1-12
1-12
2

Farm Rated Motors by Century


Moderate Torque Single Phase Capacitor Start & Two Value Capacitor Designs
Rigid Base 1800 RPM 1 1/2 thru 10 HP
Features:

Ball Bearings
Energy Efficient $

60 Hz
Service Factor 1.0

Class B or F Insulation
40C Ambient
Reversible
K213

Applications: Vacuum pumps, compressors and other moderate starting applications.



P
H


RPM


Volts

Full Load
Amps


Frame

Stock
Number


Wt.

Overload
Protector

Insulation
Class

C
Dim.

Efficiency

Notes

7.5/15.0
24.0/12.0
8.7/17.4
16.0
20.0
23.0
34.0
38.0

145T
182T
182TZ
184T
184T
213T
215T
215T

K104
K213
K119
K214
K215
K310
K311
K312

43
72
50
84
102
109
154
154

Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual

B
F
B
F
F
B
B
F

15.0
15.7
15.5
15.7
19.0
17.6
19.1
19.1


72.5
80.7
78.5
84.0
81.0
84.0
87.5

5,102,$

Farm Rated Motors by Century

Totally-Enclosed Fan-Cooled
1-12
2
2
3
5
5
7-12
10

1800
1800
1800
1800
1800
1800
1800
1800

230/115
115/230
230/115
230
230
230
230
230

5,$
5,$
5,$
5,$
5,$

Extra High Torque Motors Single & Three Phase Totally-Enclosed


Fan-Cooled Rigid Base and Rigid Base with C-Face 1800 RPM 1 thru 10 HP
Features:

High Starting Torque


Ball Bearings
60 Hz
Reversible
Removable Condensate Drain Plugs

Class B or F Insulation 40C Ambient


Service Factor 1.0
All Parts Corrosion Resistant

K208

Applications: Designed for high starting torque loads (300-400% of full load torque). Barn cleaners, silo unloaders, stock feeding conveyors,

other heavy duty farm applications.



HP


RPM


Volts

Full Load
Amps


Frame

Stock
Number


Wt.

Shaft Dia.
& Length

Overload
Protector

Insulation
Class

C
Dim.

Efficiency

Notes

Single Phase Capacitor Start


1
1
1-12
1-12
2
3
3
5
5
5
7-12
7-12
10
10
10

1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1730

Three
Phase

3
5
7-12

1800
1800
1800

115/230
115/230
115/230
115/230
115/230
230
230
230
230
230
230
230
230
230
230

14.6/7.3
14.6/7.3
16.2/8.1
16.2/8.1
24.0/12.0
13.7
13.7
22.0
22.0
26.0
38.0
38.0
39.0
39.0
39.0

143T
143TC
145T
145TC
182TZ
184T
184TC
184T
184TC
215TZ
215TZ
215TCZ
215T
215TC
215T

K102
K102C
K103
K103C
K204
K205
K205C
K208
K208C
K300
K301
K301C
K302
K302C
K302V1

38
28
42
42
78
93
93
108
108
132
131
131
146
146

7/8 x 2-1/4
7/8 x 2
7/8 x 2-1/4
7/8 x 2
7/8 x 2-3/4
1-1/8 x 2-3/4
1-1/8 x 2-5/8
1-1/8 x 2-3/4
1-1/8 x 2-5/8
1-1/8 x 3-1/2
1-1/8 x 3-1/2
1-1/8 x 3-1/8
1-3/8 x 3-1/2
1-3/8 x 3-1/8
1-3/8 x 3-1/2

Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual

B
B
B
B
F
F
F
F
F
B
B
B
F
F
F

14.2
14.4
14.2
14.4
15.7
16.2
16.9
17.4
16.9
19.2
19.1
19.9
19.1
19.9
19.1




71.0
83.0
83.0
79.0
79.0
78.6
82.0
82.0
86.5
86.5
86.5

5,$
5,$
183
5,183,$
5,183,$
5,183,$
5,183,$
183
5,183,$
5,183,$
5,183,$
5,183,$
5,183,$ New!

230/460
230/460
230/460

10.0/5.0
15.0/7.5
24.0/12.0

182T
184T
213TZ

N218
N220
N320

78
78
93

1-1/8 x 2-3/4
1-1/8 x 2-3/4
1-1/8 x 3-3/8

Manual
Manual
None

B
F
B

15.8
16.8
17.6

81.0
86.0
85.5

1,183
1,183
1,183

Notes:
1. Item to be discontinued when stock is depleted
5. $ Energy Efficient two value capacitor start capacitor run motor
102. 1.15 service factor
183. Lifting Provisions

www.centuryelectricmotor.com

Grain Stirring Motors by Century


Single Phase Capacitor Start Capacitor Run
Totally-Enclosed Fan Cooled Rigid Base 1800 RPM 1- 1/2 HP
Features:

Ball Bearings
Class B Insulation
Keyed Shaft

60 Hz
Service Factor 1.0
Moisture Resistant

40C Ambient
Reversible
Manual Overload Protector
205 Bearing, Shaft End


C317V1

HP
1-12

RPM
1800

Full Load
Amps
7.4

Volts
230


Frame
56Y

Stock
Number
C317V1


Wt.
32


Shaft
7/8 x 1.44

C
Dim.
13.3

Notes
301

Note:

301. 115 volt tap off main


winding to power gear
drive unit.

Instant Reverse Motors by Century


Instant Reverse Motors Single Phase Capacitor Start
Solid State Switching Totally Enclosed Fan-Cooled Rigid Base
1800 RPM 1/2 thru 1 HP
Features:

Ball Bearings
60 Hz

Dual Voltage
40C Ambient

Class B Insulation
Service Factor 1.0

C337

Low Temperature Grease


Manual Reset Overload Protector

Applications: Reversing feeders, door openers, gates, machine tools.



HP


RPM


Volts

Full Load
Amps


Frame

Stock
Number


Wt.

Overload
Protector

C
Dim.

C337
C338
C339

28
36
35

Manual
Manual
Manual

12.61
13.36
13.36

Notes

PT Stearns SINPAC Solid State Instant Reverse Switch


12
34
1

1800
1800
1800

115/230
115/230
115/230

www.centuryelectricmotor.com

7.2/3.6
10.4/5.2
13.0/6.5

56
56
56

Grain Stirring & Instant Reverse Motors by Century

Applications: Designed for interior grain bin installations.

Milk Pump Motors by Century


Single Phase Permanent Split Capacitor Totally-Enclosed
Non-Ventilated Rigid Base 1200 3600 RPM 1/2 thru 5 1/2 HP
Features:

Ball Bearings
60 Hz
40C Ambient
Class B Insulation
Service Factor 1.0
Stainless Steel Shaft

Non-Reversible CW Rotation Facing End Opposite Shaft


Cast Iron NEMA C End Bracket

Weatherproof Features for Washdown


B585

Applications: Milk transfer pump.


HP

RPM

Volts

Full Load
Amps


Frame

Stock
Number


Enclosure


Shaft

Insul.
Class

Overload
Protector

115/230
208-230
208-230
208-230
208-230
208-230
208-230
230

6.6/3.3
2.8-2.7
4.0-3.8
4.0-3.8
4.0-3.8
4.8-4.5
4.8-4.5
28.2

56CZ*
56HCZ
56HCZ*
56HCZ*
56HCZ*
56HCZ*
56HCZ*
215T

B587
B584
B582
B585
B592
B583
B586
V308

TENV
TENV
TENV
TENV
TENV
TENV
TENV
ODP

Threaded
Threaded
Keyed
Threaded
Special
Keyed
Threaded

B
B
B
B
B
B
B
F

Auto
Auto
Auto
Auto
Auto
Auto
Auto
Manual

56HCZ
56HCZ
56HCZ
56HCZ
56HCZ

B596
B597
B598
B595
B599

TENV
TENV
TENV
TENV
TENV

Threaded
Special
Key
Keyed
Threaded

B
B
B
B
B

Auto
Auto
Auto
Auto
Auto


Rotation

C
Dim.

Notes

Milk Pump Motors by Century

Single Phase








12
12
34
34
34
1
1
5-1/2

3450
3450
3450
3450
3450
3450
3450
1200

CW
11.3
114
CW
12.4
114
CW
12.2
CW
12.4
114
RCW
13.4
223
CW
12.2
CW
12.4
114
Rev
17.8
5,87,

159,214,$

Three Phase
12
34
34
1
1

3450
3450
3450
3450
3450

208-230/460 1.9-1.8/0.9
208-230/460 2.5-2.4/1.2
208-230

208-230/460 3.3-3.2/1.6
208-230/460

CW//CCW
RCW
RCW
RCW
RCW

11.9
13.4

12.2

NEW!
NEW!
NEW!
NEW!
NEW!



*Denotes non-standard shaft

Zero Tank Replacement


PMDC Motor Totally Enclosed Non-Ventilated 95 VDC
950 RPM Intermittent-Duty 1/2 thru 1 HP

D211

Features:

Double Sealed Ball Bearings Round Frame Class F Insulation Non-toxic, White Epoxy Paint, FDA Approved for Contact with Food
Shaft Seal All Bracket to Frame Fits and Terminal Cover have Internal O-ring Gasketed Brush Access Covers Stainless Steel Shaft,
with or without O-ring Grooves on Shaft 1/2 - 14 Tapped Conduit Hole

Applications: Improved design to replace motors on Zero Milk Tank.



HP
12
12
1
1

RPM
950
950
950
950

Volts
95
95
95
95

Full Load
Amps
5.2
5.2
11.0
11.0

Stock
Number
D201
D211
D202
D212


Wt.
30
32
36
37

C
Dim.
15.2
15.2
17.2
17.2

O-ring Grooves
No
Yes
No
Yes

Notes

Notes:

5. $ Energy efficient two value capacitor start, capacitor run motor


87. Class F insulation
159. Open dripproof
114. Threaded shaft Acme threads
214. F2 assembly
223. Direct replacement for Surge milk pumps, Babson motor #27732, requires 30 MFD,370 VAC capacitor, separately mounted - not supplied

10

www.centuryelectricmotor.com

Pedestal Fan Motors by Century


48 & 56 Frame Special Purpose Motors
Features:
Class B Insulation
Continuous Duty, Service Factor 1.0
Thermally Protected
Permanent Split Capacitor and Split Phase Designs


HP
RPM
Speeds
Volts
Amps
Frame
14
1100
2
115
6.1
48Y
1/4
1725
1
115
4.2
48YZ
1/4
1725
1
115/230
3.6/1.8
48YZ
1/4
1725
1
115
5.1
48YZ
13
1100
2
115
4.7
48Y
13
1725
1
115
6.0
48YZ
13
1725
1
115/230
3.0/1.5
48Y
12
1100
2
115
6.1
48Y
12
1725
1
115/230
4.5/2.3
48Y
12
1725
1
115
8.8
48YZ
12
1725
1
115
5.0
48YZ
12
840
1
115/230
6.1/3.1
48Y

Totally Enclosed
486A, 647A, 648A, 969A, 9451A,
9452A.
Open D.P.: 914L, 915L, 970A
Stock
Number
Wt.
Bearing
486A
21
Ball
YA2020
14
Sleeve
9451A
12
Ball
914L
14
Sleeve
647A
20
Ball
YA2030
15
Sleeve
970A
17
Ball
648A
23
Ball
9452A
23
Ball
915L
17
Sleeve
YA2054
21
Sleeve
969A
19
Ball

ShaftDia.
Rotation
& Length
12 x 3
CCWLE
1/2 x 2
REV
12 x 3-14
CCWLE
12 x 2
REV
12 x 3
REV
1/2 x 2
REV
1/2 x 2-1/2
CCWLE
58 x 3
REV
58 x 2-12
CCWLE
58 x 2
REV
5/8 x 2
REV
5/8 x 2-5/8
CCWLE

Totally Enclosed
YA2020, YA2030,
YA2054
C
Dim.
10.4
9.8
9.3
9.9
9.9
10.3
8.9
10.9
10.2
10.8
10.8
11.0

Notes
29,86
39,314

26,86
39,314
3,6
86
314
39,84
3

Notes:
3. Special OEM motor
6. 60/50 HZ
26. Extended thru bolts shaft end only
29. 60 Degree C Ambient
39. Gasketed conduit box
84. Energy Efficient split phase start capacitor run with mounted capacitor
86. Cord and plug with pull chain
314. 1 extended thru bolts

www.centuryelectricmotor.com

11

Pedestal Fan Motors by Century

Yoke Mount
40CAmbient
60 Hz

Poultry Duty Motors


Features:

Ball Bearings
Class B Insulation
High Starting Torque
Reversible
Suitable for 208 Volts at 1.0 S.F.

TEAO
4 Pole
40C Ambient
60 Hz
Energy Efficient $(see notes)

PD6104AV2

RIGID AND RESILIENT BASES



HP
1/2
1
1


RPM
1725
1725
1725


Volts
115/208-230
115/230
115/230

Full Load
Amps
4.8/2.4
9.0/4.5
9.0/4.5

Service
Factor
1.30
1.30
1.30


Frame
56
56
56

Stock
Number
PD1050AV1
PD6104AV2*
PD6104AV3


Wt.
26
26
40


Protector
Auto
Auto
Auto

Approx.
C
10.8
12.7
12.8

Dim.
AG Enclosure Notes
8.8
TEAO
6,117
10.6
TEAO
6,85,117
10.1
TEAO 6,34,85,117

$
$

Notes:

Shaft Dimensions
56 = 5/8 Keyed x 1-7/8

Poultry Duty Motors

6. 60/50 HZ
34. Rigid base
85. Energy efficient $ - capacitor start/capacitor run
117. TEAO - gasketed conduit box
*Resilient Base

12

www.centuryelectricmotor.com

Pressure Washer Motors by Century


Single Phase - Dripproof & Totally Enclosed Fan-Cooled
Rigid Base 3600 & 1800 RPM 1.5 thru 6 HP
Features:

Double Sealed Ball Bearings


60 Hz
40C Ambient
Class B Insulation
Manual Overload Protector
Reversible
Service Factor 1.15
Energy Efficient $
Two Step Varnish Treatment Rotor surface and bearing brackets coated with corrosion resistant primer.
One dip and bake of Class B Varnish is applied to wound stator. The entire stator assembly is dipped in a second coating of varnish and
baked to seal out moisture.

B861

Applications: High Pressure washers (sprayers) and other applications.



HP


RPM


Volts

Dripproof Standard Bracket


1-12
1-12
2
2
2
3
3
5
5
6

1-12
1-12
2
2
3
5

1-12
1-12
2
2
3
3


Frame

Stock
Number


Wt.


Shaft

C
Dim.

Notes

3600
1800
3600
3600
1800
3600
1800
3600
3600
3600

115/230
115/208-230
115/208-230
115/208-230
115/230
208-230
208-230
208-230
208-230
230

13.0/6.5
13.4/7.2-6.7
17.2/9.2-8.6
17.2/9.2-8.6
18.0/9.0
13.5-12.5
13.5
22.0
22.0
24.0

56
56
56
56
56H
56H
145T
56HZ
56Y
56Y

B176
C775
B177
B177L
C210
B178
C218
B179
B180
B869

25
35
34
34
32
35
45
46
52
50

5/8
5/8
5/8
5/8
5/8
5/8
7/8
7/8
7/8
7/8

11.4
12.2
12.7
12.7
14.4
12.7
15.1
14.6
14.6
14.6

$
$
$
$
$
$
$
160,$
97,160,$
49,97,160,$

3600
1800
3600
1800
3600
3600

115/230
115/230
115/208-230
115/230
208-230
208-230

13.0/6.5
13.4/6.7
17.2/9.2-8.6
18.0/9.0
13.5-12.5
22.0

56C
56C
56C
56HC
56HCZ
56HCZ

B870
C776
B860
C215
B867
B182

25
36
36
42
36
42

5/8
5/8
5/8
5/8
3/4
3/4

11.5
12.2
12.7
14.4
12.5
14.5

$
$
$
$
$
160,$

3600
1800
3600
1800
3600
3600

115/230
230/115
115/208-230
115/230
230
230

13.0/6.5
7.5/15.0
16.6/9.1-8.4
17.0/8.5
12.0
12.0

56C
56C
56HC
56HC
56HC
56HC

B871
C777
B861
C213
B382
B868

33
44
43
47
48
48

5/8
5/8
5/8
5/8
5/8
3/4

12.7
13.7
14.2
14.4
15.2
15.0

$
$
$
$
$
$

Dripproof NEMA C Bracket

Dripproof Standard Bracket

Notes:
49. 1.0 Service Factor
97. 182T and 184T mounting holes,
4.5 shaft height
160. Non-reversible, Connected for
CW facing end-opposite shaft

www.centuryelectricmotor.com

13

Pressure Washer Motors by Century

Full Load
Amps

Three Phase TEFC Motors


Features:
Ball Bearings
Class F Insulation
Continuous Duty
Energy Efficient $
NEMA Design B
Rigid Base
Squirrel Cage
Totally Enclosed

No Protector
Standard, EPAct
CC001A
(E-Plus motors) and Premium
(E-Plus 3 motors) Efficiency
14 thru 400 HP
1.15 Service Factor
40C Ambient
60 Hz

56 Frame and larger


3600, 1800 and 1200 RPM
E-Plus 3 motors exceed the requirements of the Energy Policy Act of
1992. E+3(NP) is NEMA Premium
Efficient.

T46026

Applications:

Three Phase TEFC Motors

Pumps, fans, compressors, conveyors, machine tools, designed to stand up to abusive treatment..moist, dirty, dusty and factory applications.

HP
RPM
Volts
1
1800
230/460
1
1800
575
1800
230/460
1-12
1-12
1800
575
2
230/460
1800
575
2
1800
3
1800
200
1800
575
3
5
1800
230/460
575
5
1800
7-12
1800
230/460
1800
575
7-12
1800
230/460
10
10
1800
575
15
1800
230/460
15
1800
575
20
1800
230/460
20
1800
575
25
1800
230/460
25
1800
575
30
1800
230/460
30
1800
575
40
1800
230/460
40
1800
575
50
1800
230/460
50
1800
575

Full Load
Amps
2.8/1.4
1.1
4.2/2.1
1.7
5.8-5.6/2.8
2.2
9.0
3.1
12.8/6.4
5.1
18.2/9.1
7.3
23.8/11.9
9.5
37.0/18.5
14.8
49.0/24.5
19.6
60.0/30.0
24.0
72.0/36.0
28.8
94.8/47.4
38.0
118.0/59.0
47.2


Frame
143T
143T
145T
145T
145T
145T
182T
182T
184T
184T
213T
213T
215T
215T
254T
254T
256T
256T
284T
284T
286T
286T
324T
324T
326T
326T

Stock
Number
Wt.
T57026 J
47
T59026 J
47
T57027 J
54
T59027 J
54
T57028 J
56
T59028 J
56
T55029 J
91
T59029 J
91
T57030 J
108
T59030 J
108
T57031 J
159
T59031 J
159
T57032 J
185
T59032 J
185
T57033 J
285
T59033 J
285
T57034 J
315
T59034 J
315
T57035 J
452
T59035 J
452
T57036 J
481
T59036 J
461
T57037 J
615
615
T59037 J
T57038 J
721
T59038 J
721

Cast
Iron
Type

E+3(NP)

E+3(NP)

E+3(NP)
E+3(NP)


E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)

E+3(NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)
E+3 (NP)

C
Dim. Efficiency
Notes
13.2
85.5
11,361,363
13.2
85.5
11,363,365
13.2
86.5
11,361,363
13.2
86.5
11,363,365
13.2
86.5
11,361,363
13.2
86.5
11,363,365
15.4
89.5
11,363,365
15.4
89.5
11,363,365
15.4
89.5
11,361,363
15.4
89.5
11,363,365
19.4
91.7
11,362,363
19.4
91.7
11,363,365
19.4
91.7
11,362,363
19.4
91.7
11,363,365
25.1
92.4
11,362,364
25.1
92.4
11,364,365
25.1
93.0
11,362,364
25.1
93.0
11,364,365
26.9
93.6
11,362,364
26.9
93.6
11,364,365
28.4
93.6
11,362,364
28.4
93.6
11,364,365
29.7
94.1
11,362,364
29.7
94.1
11,364,365
31.3
94.5
11,362,364
31.3
94.5
11,13,364,365

Notes:
Motors specially designed, tested and warranted to
11. C flange kit available
be Corona-Free for compatible inverter duty are
13. Six lead motor suitable for part winding start
marked on this page with a J.
23. Suitable for 200/400 Volt and 50 HZ
361. 9 leads
363. Double shielded bearings with no regreasing provisions
365. 3 leads
Published efficiency on tri-voltage rated motors applies at 230/460 volts.
Performance at 200 or 208 volts may not be in accordance with NEMA standards.
Published efficiency on 200-208 volt motors applies at 200 volts.

14

www.centuryelectricmotor.com

General Purpose IHP Motor Dimensions


Single and Three Phase 143T-449T Frame Dripproof Totally Enclosed Explosion-Proof
56H Combination Foot
6.50

5.00
Ref.

3.00
Ref.

2.75

143T
145T
182T
184T
213T
215T
254T
256T
284T
284TS
286T
286TS
324T
324TS
326T
326TS

Keyway

316 x 332
316 x 332
14 x 18
14 x 18

516 x 532
516 x 532
38 x 316
38 x 316
12 x 14

38 x 316
12 x 14

38 x 316
12 x 14
12 x 14
12 x 14
12 x 14

BA

2.25
2.25
2.75
2.75
3.50
3.50
4.25
4.25
4.75
4.75
4.75
4.75
5.25
5.25
5.25
5.25

D
1

3.50
3.50
4.50
4.50
5.25
5.25
6.25
6.25
7.00
7.00
7.00
7.00
8.00
8.00
8.00
8.00

2F

2.75
2.75
3.75
3.75
4.25
4.25
5.00
5.00
5.50
5.50
5.50
5.50
6.25
6.25
6.25
6.25

4.00
5.00
4.50
5.50
5.50
7.00
8.25
10.00
9.50
9.50
11.00
11.00
10.50
10.50
12.00
12.00

1132
1132
1332
1332
1332
1332
1732
1732
1732
1732
1732
1732
2132
2132
2132
2132

2.31
2.31
2.81
2.81
3.50
3.50
4.25
4.25
4.88
3.50
4.88
3.50
5.50
4.00
5.50
4.00

U
2

.875
.875
1.125
1.125
1.375
1.375
1.625
1.625
1.875
1.625
1.875
1.625
2.125
1.875
2.125
1.875

2.00
2.00
2.50
2.50
3.13
3.13
3.75
3.75
4.38
3.00
4.38
3.00
5.00
3.50
5.00
3.50

Notes:
1 Dimension

D tolerance: - 8 or less, +.000, -.031; over 8, +.000-.062


Utolerance: - 112 dia. or less, +.0000, -.0005; over 112 dia., +.000, -.001
3 Dimension V is usable length of shaft
4 Suitable for horizontal mounting only. Refer to company for belting applications.
5 Crusher-duty motors Spec 80546
2 Dimension

Common to all Fractional Motors


Frame

42
48
56
56H
56C
56J
143T
145T

Keyway

.05 Flat
.05 Flat
3/16 sq. x 1-3/8
3/16 sq. x 1-3/8
3/16 sq. x 1-3/8
Threaded
3/16 sq. x 1-3/8
3/16 sq. x 1-3/8

2-5/8
3
3-1/2
3-1/2
See Diagram 2
See Diagram 2
3-1/2
3-1/2

1-3/4
2-1/8
2-7/16
Dia. 1


2-3/4
2-3/4

27/32
1-3/8
1-1/2
Dia. 1


2
2-1/2

BA

2-1/16
2-1/2
2-3/4
2-3/4


2-1/4
2-1/4

3/8
1/2
5/8
5/8
5/8
5/8
7/8
7/8

N-W

1-1/8
1-5/8
1-7/8
1-7/8
1-7/8
2-7/16
2-1/4
2-1/4

For Reference Only Unless Approved for Construction

www.centuryelectricmotor.com

15

General Purpose IHP Motor Dimensions

NEMA
Frame

2.75

NEMA Frame Assignments


Open and TEFC (TEFC Frame in Beige where different than open)
3600 RPM

900 RPM

T
Frames
1964

U
Frames
1952

Original
NEMA
Frames

182

203

145T

184

204

182T

213

225

145T

184

204

182T

184

224

184T

213

254

204

145T

184

224

184T

213

225

213T

215

254

184

224

182T

213

225

213T

215

254

215T

254U

284

182T / 184T

213

225

184T

215

254

215T

254U

284

254T

256U

324

7 1/2

184T / 213T

215

254

213T

254U

284

254T

256U

324

256T

284U

326

10

213T / 215T

254U

284

215T

256U

324

256T

284U

326

284T

286U

364

15

215T / 254T

256U

324

254T

284U

326

284T

324U

364

286T

326U

365

20

254T / 256T

284U/286U

326

256T

286U

364

286T

326U

365

324T

364U

404

25

256T / 284TS

286U/324U

364S/365S

284T

324U

364/365

324T

364U

404

326T

365U

405

30

284TS / 286TS

324S/326S

364S/404S

286T

326U

365/404

326T

365U

405

364T

404U

444

40

286TS / 324TS

326S/364US

365S/405S

324T

364U

404/405

364T

404U

444

365T

405U

445

50

324TS / 326TS

364US

404S/444S

326T

365US

405S/444S

365T

405U

445

404T

444U

504U

60

326TS / 364TS 365US/405US 405S/445S

364TS

404US/405US

444S/445S

404T

444U

504U

405T

445U

505

75

364TS / 365TS 404US/444US 444S/504S

365TS

405US/444US

445S/504S

405T

445U

505

444T

100

365TS / 405TS 405US/445US 445S/505S

404TS/405TS

444US/445US

504S/505S

444T

445T

125

404TS / 444TS

444US

504S

405T /444TS

445US

505S

445T

150

405TS / 445TS

445US

505S

444TS/445TS

200

444TS

445TS

250

445TS

U
Frames
1952

Original
NEMA
Frames

143T

1 1/2

143T

182

203

145T

184

145T / 182T

Hp
1

16

T
Frames
1964

U
Frames
1952

1200 RPM
Original
NEMA
Frames

T
Frames
1964

NEMA
Frame

NEMA Frame Assignments

1800 RPM

T
U
Original
Frames Frames NEMA
1964
1952
Frames

www.centuryelectricmotor.com

Pulley Speed Chart

PULLEY SPEED CHART

Speeds are approximate, based on 1725 RPM motor.


Speeds are approximate, based on 1725 RPM motor.

Motor
Pulley
Diameter
Motor
Pulley
Diameter
1.5

3.0
3.5
4.0
4.5
5.0
5.5
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
10.5
11.0
11.5
12.0
12.5
13.0
13.5
14.0
14.5
15.0
15.5
16.0
16.5
17.0
17.5
18.0

2.0

2.5

2.75

3.0

3.25

3.5

3.75

4.0

4.25

4.5

4.75

5.0

5.25

5.5

5.75

6.0

6.5

7.0

7.5

1725
1533
1380
1255
1150
1062
986
920
863
812
767
726
690
657
627
600
575
552
531
511
493
476
460
445
431
418
406
394
383

1629
1466
1333
1222
1128
1047
978
916
863
815
772
733
698
666
638
611
587
564
543
524
506
489
473
458
444
431
419
407

1725
1553
1411
1294
1194
1109
1035
970
913
863
817
776
739
706
675
647
621
597
575
554
535
518
501
485
470
457
444
431

1639
1490
1366
1261
1171
1093
1024
964
910
863
819
780
745
713
683
656
630
607
585
565
546
529
512
497
482
468
455

1725
1568
1438
1327
1232
1150
1078
1015
958
908
863
821
784
750
719
690
663
639
616
595
575
556
539
523
507
493
479

1647
1509
1393
1294
1208
1132
1065
1006
953
906
863
823
788
755
725
697
671
647
625
604
584
566
549
533
518
503

1725
1581
1460
1355
1265
1186
1116
1054
999
949
904
863
825
791
759
730
703
678
654
633
612
593
575
558
542
527

1653
1526
1417
1323
1240
1167
1102
1044
992
945
902
863
827
794
763
735
708
684
661
640
620
601
583
567
551

1725
1592
1479
1380
1294
1218
1150
1089
1035
986
941
900
863
828
796
767
739
714
690
668
647
627
609
591
575

1725
1602
1495
1402
1319
1246
1180
1121
1068
1019
975
934
897
863
831
801
773
748
723
701
680
660
641
623

1725
1610
1509
1421
1342
1271
1208
1150
1098
1050
1006
966
929
894
863
833
805
779
755
732
710
690
671

1725
1617
1522
1438
1362
1294
1232
1176
1125
1078
1035
995
958
924
892
863
835
809
784
761
739
719

RPM
X Motor
Diameter
MotorMotor
RPM X
Motor
PulleyPulley
Diameter
Driven
RPM =
Driven
PulleyPulley
RPM =
Diameter
DrivenDriven
PulleyPulley
Diameter

www.centuryelectricmotor.com

17

Pulley Speed Chart

Driven Pulley Diameter

6.0

1.75

863 1006 1150 1438 1581 1725


739 863 986 1232 1355 1479 1602 1725
647 755 863 1078 1186 1294 1402 1509 1617
575 671 767 958 1054 1150 1246 1342 1438
518 604 690 863 949 1035 1121 1208 1294
470 549 627 784 863 941 1019 1098 1176
431 503 575 719 791 863 934 1006 1078
398 464 531 663 730 796 863 929 995
370 431 493 616 678 739 801 863 924
345 403 460 575 633 690 748 805 863
323 377 431 539 593 647 701 755 809
304 355 406 507 558 609 660 710 761
288 335 383 479 527 575 623 671 719
272 318 363 454 499 545 590 636 681
259 302 345 431 474 518 561 604 647
246 288 329 411 452 493 534 575 616
235 274 314 392 431 470 510 549 588
225 263 300 375 413 450 488 525 563
216 252 288 359 395 431 467 503 539
207 242 276 345 380 414 449 483 518
199 232 265 332 365 398 431 464 498
192 224 256 319 351 383 415 447 479
185 216 246 308 339 370 400 431 462
178 208 238 297 327 357 387 416 446
173 201 230 288 316 345 374 403 431
167 195 223 278 306 334 362 390 417
162 189 216 270 296 323 350 377 404
157 183 209 261 288 314 340 366 392
152 178 203 254 279 304 330 355 381
148 173 197 246 271 296 320 345 370
144 168 192 240 264 288 311 335 359

Fraction/Decimal/Millimeter Conversions

Fraction

Millimeter

Fraction

.015625

0.397

33

64

64

32

.03125

0.794

17

64

.046875

1.191

35

16

.0625

1.588

16

64

.078125

1.984

37

32

.09375

2.381

19

64

.109375

2.778

39

.125

3.175

1
3
1

5
3

NEMA Frame Assignments

Decimal

Millimeter

MM

.515625

13.097

.0394

32

.53125

13.494

.0787

64

.546875

13.891

.1181

.5625

14.288

.1575

64

.578125

14.684

.1969

32

.59375

15.081

.2362

64

.609375

15.478

.2756

.625

15.875

.3150

64

.640625

16.272

.3543

32

.65625

16.669

10

.3937

64

.671875

17.066

11

.4331

16

.6875

17.463

12

.4724

64

.703125

17.859

13

.5118

64

.140625

3.572

41

32

.15625

3.969

21

64

.171875

4.366

43

16

.1875

4.763

11

64

.203125

5.159

45

32

9
5

11
3

13

Decimal

Inch

.21875

5.556

23

32

.71875

18.256

14

.5512

15

.234375

5.953

47

64

.734375

18.653

15

.5906

.25

6.350

.75

19.050

16

.6299

17

64

.265625

6.747

49

64

.765625

19.447

17

.6693

.28125

7.144

25

32

.78125

19.844

18

.7087

.296875

7.541

51

64

.796875

20.241

19

.7480

16

.8125

20.638

20

.7874

64

.828125

21.034

21

.8268

64

32
9

64

19

16

.3125

7.938

13

64

.328125

8.334

53

32

.34375

8.731

27

32

.84375

21.431

22

.8661

64

.359375

9.128

55

64

.859375

21.828

23

.9055

.375

9.525

.875

22.225

24

.9449

64

.890625

22.622

25

.9843

32

.90625

23.019

64

.921875

23.416

16

.9375

23.813

64

.953125

24.209

32

.96875

24.606

64

.984375

24.003

1.0

25.400

21

11
23

64

.390625

9.922

57

32

.40625

10.319

29

64

.421875

10.716

59

16

.4375

11.113

15

64

.453125

11.509

61

32

.46875

11.906

31

64

.484375

12.303

63

.5

12.700

25
13
27
7

29

15
31

18

To convert millimeters
into inches, multiply
by .03937.

To convert inches into
millimeters, multiply by
25.40.

www.centuryelectricmotor.com

Statement of Warranty Policy


Warranty Period

DISCLAIMER OF IMPLIED WARRANTIES

All Century motors are warranted against defects in materials and


workmanship for a period of twelve (12) months from the date of installation or twenty-four months (24) from the date of manufacture, whichever comes first except for E-Plus3 Integral Horsepower Motors and
HeatMaster Condenser Fan Motors which are warranted for twenty-four
months (24) from date of installation and thirty-six (36) months from date
of manufacture, whichever comes first.

EXCEPT AS MAY BE REQUIRED UNDER APPLICABLE LAW, THE LIMITED


WARRANTY SET FORTH ABOVE IS THE EXCLUSIVE WARRANTY PROVIDED
WITH THE MOTORS. ALL OTHER WARRANTIES, WHETHER WRITTEN OR
VERBAL, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
EXPRESSLY DISCLAIMED BY CENTURY.

Limitation of Remedy

Conditions of Warranty
This limited warranty shall be void and of no effect if:

In the event of a breach of the warranty within the applicable warranty


period, Century shall have the option of (1) repairing such motor; (2)
supplying an identical or substantially similar replacement motor FOB,
Centurys factory; or (3) refunding or giving credit for the purchase price
of such motor.

Authorized Location
Defective motors which have failed during the applicable warranty period must be
returned freight prepaid to a Centurys authorized distributor. Call 800-672-6495.

How to Read Date Codes on Motor Nameplates & Labels


As of August 2006 a common date code format
for all motors is being used. It consists of
seven alpha-numeric characters. The first three
characters represent the day of the year based
on the Julian calendar, the next two the year,
and the last two the plant code. For example,
123064M, would mean the 123rd day of 2006
(May 3, 2006) in Regals Juarez IGMEX4 plant.
Users and distributors may visit our website
centuryelectricmotor.com to access our date
code converter, as well as applicable warranty
forms.
The date codes utilized prior to the conversion to our current format are listed below for your reference.

Century Product

Plant codeMonthYear. Example: 7B99. 7 is a plant code designation, B is the month (January is A, February is B, etc.) and 99 is the year.
Century, Indiana General, Louis Allis Product
Year codeMonth. Example: BA3. BA is the year (see table below). 3 is the month (1-12).
1992
1993
1994
1995

BK
BL
BM
BN

1996
1997
1998
1999

BP
BR
BS
BT

2000
2001
2002
2003

BU
BW
BX
BY

2004
2005
2006
2007

BZ
CA
CB
CC

2008
2009
2010

CD
CE
CF

Universal Product

Week (1-52), Year (Letter code from table below), Factory order number code, Plant code.
Example: 8 Z 0275592 R. 8 is the 8th week of the year, Z is the year (1988), 027592 is the factory order code, R is the plant code (Ripley).
1992
1993
1994
1995

D
E
F
G

1996
1997
1998
1999

H
J
K
L

2000
2001
2002
2003

M
N
P
R

2004
2005
2006
2007

S
T
U
V

2008
2009

W
X

Statement of Warranty Policy

The remedy set forth above shall be the sole and exclusive remedy for the
motors failing within the applicable warranty period. Century, shall not be
liable for any lost profits, loss of use, or any other consequential, special
or incidental damages.

1. The motor has been subjected to improper handling, storage or installation,


or subject to abuse or unauthorized repairs;
2. The motor was not suitable for the application or operated above its rated
load; or
3. The motor was subject to water damage including motor bearing failures
resulting from pump seal failures.

Formerly A. O. Smith Electrical Products Company

Distribution Marketing
1325 Heil Quaker Blvd.
LaVergne, TN 37086
PH: 800-672-6495
FAX: 800-468-2062

A Regal Brand

www.centuryelectricmotor.com
2012 Regal-Beloit Corporation

Bulletin 1401C

6/2012

You might also like