Mounting lnstructions

RTC89.7XX Touch Screen Programming Thermostat


RTC89.7XX touch screen programming thermostat Weekly circulation, it is possible to set 6 periods called events each day with different temperatures, also you can select 'manual mode'or "comfort mode" according to your individual requiremenls. The thermostat is recommended for the control of electric heating devices or on/off valve actuator used in water-based healing sysiems.

Daily use of the thermostat


Press the "ffi" key to select manual mode or clock-controlled programme mode, use the key to enter into comfort mode in clock-controlled programme mode 2 ) plus'l'& minus "v" Press the "A' or'1" key to increase or decrease your set value 3 ) clock'O' Press the "O" key to set the time and day press the "O" key till the day start blinking, use the "A" or'7' key to set the day, press the 'O" key to confirm the setting and the hours start blinking, use the '4" or "V" key to set the hours, press the 'f or a'to confirm the setting and the minutes start blinking, use the " 'or "f key to set the minutes, press the "O" key to accept the settings 4 ) on/off "O" ' Press the "(D' key to switch on or swltch off the thermostat the setted temperature and the time will be displayed alternately, and the room lemperature can be directly read out on the screen
1 ) menu

fr'

Selection Table

Technical data:
Voltage Setting

Powerconsumplion :2W

AC230V(AC1 1 0V /AC24V available)

range Limitation range

: 5'C
:

90"C

4'C - 99'C (factory setting: 28'C-32'qC)

Switching differential : t0.5K Ambient temperature : -5 - 50'C

Protectivehousing
Housing material Floor sensor

:lP2O : anti-flammable PC : rubber-thermoplastic NTC sensor,


cable length is 3m

Programming: 6-event time and temperature


Press the Key

'm"

for 5 seconds to start


Time
A V

Function:

Event Symbol

Temperature
20"c

'!"

manual mode The scheduled event program is overridden, set the temperature according to your individual requirements an d the thermostat will operate at this temperature permanently

l I a o
@

"O'

clock-controlled programme mode


The day has been split into 6 events, the thermostat will operate automatically according to the programmed temperature and time

NR

1 ? o E
q

06:O0

I 4
5
A
1

;
c.
O
o.

08:OO
11 :3O

o o
D

15"C
15qC

o 3

12:30
17:OO

15"C

t-

- -"#+',ea1T*ortmod6 -

0
C,

The temperature can be temporarily changed for a single event, the comfort mode temperature is reset at the next event, and the thermostat will return to the scheduled event program
Nole:

-{+

-22:3O
08:OO 23:OO

o
o

22"C

-.

l5ic-,-_
22"C

15"c

tSl Gl Gl @l @ @ l2l $l !l!l $!l @ lll @t @ ffi @ @ jl

wake-up, event t teaue (am), event 2


Return (am), event 3 Leaue 1pm), eYent4

1) the pre-programmed setpoint (1UC) for event 3 & I is the same as event 2, please reset it according to you individual rcquirement 2) symbol "OFF' will be ctisplayed if the setpoint reachs lhe minimum set value and the thermostat is switched off in this event

Advanced settings (qualified person preferred)


Press the "Ci' key simultaneously switching on the thermostat to enter into the advanced selting mode(when the device is switched off)

neturnlpm),event5 steep,evento
Heatins on

Key

Symbol ADJ

Setting

A orV
OUT: floor sensor ALL : both sensor
(floor sensor is lhe limit sensor

lemperature calibratior Adjust measured temperature

lN

: built-in sensor

'xey-toct" function

is activated

s"t

""n"or

mode: built-in/floor/both sensors

an

SEN

Sensor mode

set vacation operating mode

vax. limitation lemperature setpoint


rtrin. Limitation temperature setpoint

eaay-startadaplivefunction

o
0

3 4 5 6

HI

Max. Temperature

Vax. Limitation temperature


rclnninl /QQ'C\

LO

Min. Temperature Vin. Limitation temperature rclonint /4oC\


Adaptive functiqn
Set vacation mode CN : prheating 30mirut6 early
OFF: cancel adaptive function

ADA
PRG

S"n"o,

""libration

to ensure accurate temperature measurement

oisptay with back light, stay on for 20 seconds

2 : 512 day mode 'I : 6/1 day mode

0: Tdaymode
7

lcooisptayforbetterread

out FAC

oisplayactual roomtemperaturewhen switch-off


Touch screen operating interface

Reset to factory settings

rrogramming parameters will )e reset to factory settings ilhen symbol "- - -'appears

Sensor failure:

"Key-lock' function
Press both the

"

" and "V" keys for 5 secs to engage/disengage the

( tI" symbol appear means 'key-lock" function is activated; disappear means "key-lock' function is deactivated)

'key-lock'function

Please select the right sensor mode when operation, it will display the "Err'symbol on screen for sensor failure, thermoslat must be checked till the fault is eliminated

HVAC CONTROLS PRODUCTS

DS/MRD-06-E-1 00203

Mounting lnstructions
RTC89.7XX Touch Screen Programmin g Thermostat
Explanation of symbols
Housing Clock-controlled programmg mode Event indicator
Set value/time display Day number

cover

Power base

Menu key Plus/minus key

manual mode Actual temperature Heating on Key lock On/off switch Temperature sensor Clock k6y

cover and the powet base when install the thermostat

Clock-controlled programme mode manual mode Meiu key Actual temperature Clock key On/off switch Set value/time display Key lock Temperature sensor
!

lnstall the thermostat in electrical connection box with screws

Dimension

lnstall the housing cover and lock the extsrnal frame


1

3
I

ts-

86mm _,,,_N

-i

ro..

FH li

i:""i
89.713 I 2 3 4i] 6ilAv

L NL1
AC230V 3A

89.723 i1 l2lt|4 i'l6l7r

++ ! -,+ I I' _ _ _P U L N Ll >!.seruSon Ac23ov 3A

89.716

LN
AC230V

SENSOR

tt ]I

HVAC CONTROLS PRODUCTS

DS/MRD-06-E-1 00203