You are on page 1of 2

PROJECT : PROJ. NO.

: CLIENT: UNIT :

case 7

DATE : BY : REV : DOC NO.:

04-Jan-10 S. Rahimi A

Salt Balance (Single Stage Desalter + Upstream Separator) Salinity Calculation chloride Conc. In feed Chloride in washing water Mixing Efficiency Outlet Oil Salt Content Feed Salinity Washing Water Salinity Feed Salinity Washing Water Salinity

mg/lit mg/lit % PTB mg/lit mg/lit lb/BBL lb/BBL

133300 244 60 18 219663 402 76.84 0.14

Salt Balance Calculation Parameter Oil Flow Rate Water Percent Free water (unmixed) Water Flow Rate Salt Content Salt Content Salt Content Unit BOPD Vol% BWPD BWPD lb/day lb/BBL PTB

1 FEED Stream 224054 5.4 12790 12790 982728 76.84 4386.12

2 8 3 Stream to Separator Out of Separator Reject Separator 224054 13.38 29988 23108 1113604 48.19 4970.25 224054 11.34 25415 25415 980502 38.58 4376.19 224054 2 4573 4573 220353 48.19 983.48

7 Fresh Water 224054 5.74 12850 12850 1807 0.14 8.07

4 6 9 10 11 Stream to Desalter Desalter Recycle to Desalter Desalter water out Int. Recir. Seperator Reject 224054 7.86 17602 12390 222804 17.98 994.42 224054 7.76 17378 17378 220405 12.68 983.72 224054 0.08 180 180 2278 12.68 10.17 224054 7.68 17198 17198 218127 12.68 973.55 0.00 224054 0.00 0 0 3 12.68 0.01

5 Out of Desalter 224054 0.1 224 224 4033 17.98 18.00

Calculation Summary Oil Flow Rate Fresh Water Consumption Separator Internal Recirculation Desalter Internal Recirculation Package recirculation Package Reject (Desalter) Package Reject (Separator)

m3/hr m3/hr m3/hr m3/hr m3/hr m3/hr m3/hr

1484.4 85.1 0.0 1.2 113.9 0.0 168.4

www.chemwork.org

PROJECT : PROJ. NO.: CLIENT: UNIT :

case 7

DATE : BY : REV : DOC NO.:

04-Jan-10 S. Rahimi A

Salt Balance (Single Stage Desalter + Upstream Separator)

7 SEPARATOR 1 2 9 10 4 6 DESALTER

11

Notes

www.chemwork.org