You are on page 1of 2

ENDOSMOSIS BOILER REGULATION TABLE

1P, 2kW
(10A)

1P, 1kW
(5A)

1P, 3kW
(15A)

1P, ~3kW
(16A)

1P, 4kW
(20A)

1P, 5kW
(25A)

1P, 6kW
(30A)

1P, 7kW
(35A)

1P, 8kW
(40A)

1P, 9kW
(45A)

1P, 10kW
(50A)

3P, 5kW
(8,3A)

3P, 6kW
(10A)

5
10
15
20
25
30
35
40
45
50
60
70

0,36
0,71
1,07
1,43
1,79
2,14
2,50
2,86
3,21
3,57
4,29
5,00

5
10
15
20
25
30
35
40
45
50
60
70

0,71
1,43
2,14
2,86
3,57
4,29
5,00
5,71
6,43
7,14
8,57
10,00

5
10
15
20
25
30
35
40
45
50
60
70

1,07
2,14
3,21
4,29
5,36
6,43
7,50
8,57
9,64
10,71
12,86
15,00

5
10
15
20
25
30
35
40
45
50
60
70

1,14
2,29
3,43
4,57
5,71
6,86
8,00
9,14
10,29
11,43
13,71
16,00

5
10
15
20
25
30
35
40
45
50
60
70

1,43
2,86
4,29
5,71
7,14
8,57
10,00
11,43
12,86
14,29
17,14
20,00

5
10
15
20
25
30
35
40
45
50
60
70

1,79
3,57
5,36
7,14
8,93
10,71
12,50
14,29
16,07
17,86
21,43
25,00

5
10
15
20
25
30
35
40
45
50
60
70

2,14
4,29
6,43
8,57
10,71
12,86
15,00
17,14
19,29
21,43
25,71
30,00

5
10
15
20
25
30
35
40
45
50
60
70

2,50
5,00
7,50
10,00
12,50
15,00
17,50
20,00
22,50
25,00
30,00
35,00

5
10
15
20
25
30
35
40
45
50
60
70

2,86
5,71
8,57
11,43
14,29
17,14
20,00
22,86
25,71
28,57
34,29
40,00

5
10
15
20
25
30
35
40
45
50
60
70

3,21
6,43
9,64
12,86
16,07
19,29
22,50
25,71
28,93
32,14
38,57
45,00

5
10
15
20
25
30
35
40
45
50
60
70

3,57
7,14
10,71
14,29
17,86
21,43
25,00
28,57
32,14
35,71
42,86
50,00

5
10
15
20
25
30
35
40
45
50
60
70

0,59
1,19
1,78
2,37
2,96
3,56
4,15
4,74
5,34
5,93
7,11
8,30

5
10
15
20
25
30
35
40
45
50
60
70

0,71
1,43
2,14
2,86
3,57
4,29
5,00
5,71
6,43
7,14
8,57
10,00

3P, 7KW
(11,7A)

3P, 8kW
(13,3A)

3P, 9kW
(15A)

3P, ~9kW
(16A)

3P, 10kW
(16,7A)

3P, 11kW
(18,3A)

3P, 12kW
(20A)

3P, 13kW
(21,7A)

3P, 14kW
(23,3A)

3P, 15kW
(25A)

3P, 16kW
(26,7A)

3P, 17kW
(28,3A)

3P, 18kW
(30A)

5
10
15
20
25
30
35
40
45
50
60
70

0,84
1,67
2,51
3,34
4,18
5,01
5,85
6,69
7,52
8,36
10,03
11,70

5
10
15
20
25
30
35
40
45
50
60
70

0,95
1,90
2,85
3,80
4,75
5,70
6,65
7,60
8,55
9,50
11,40
13,30

5
10
15
20
25
30
35
40
45
50
60
70

1,07
2,14
3,21
4,29
5,36
6,43
7,50
8,57
9,64
10,71
12,86
15,00

5
10
15
20
25
30
35
40
45
50
60
70

1,14
2,29
3,43
4,57
5,71
6,86
8,00
9,14
10,29
11,43
13,71
16,00

5
10
15
20
25
30
35
40
45
50
60
70

1,19
2,39
3,58
4,77
5,96
7,16
8,35
9,54
10,74
11,93
14,31
16,70

5
10
15
20
25
30
35
40
45
50
60
70

1,31
2,61
3,92
5,23
6,54
7,84
9,15
10,46
11,76
13,07
15,69
18,30

5
10
15
20
25
30
35
40
45
50
60
70

1,43
2,86
4,29
5,71
7,14
8,57
10,00
11,43
12,86
14,29
17,14
20,00

5
10
15
20
25
30
35
40
45
50
60
70

1,55
3,10
4,65
6,20
7,75
9,30
10,85
12,40
13,95
15,50
18,60
21,70

5
10
15
20
25
30
35
40
45
50
60
70

1,66
3,33
4,99
6,66
8,32
9,99
11,65
13,31
14,98
16,64
19,97
23,30

5
10
15
20
25
30
35
40
45
50
60
70

1,79
3,57
5,36
7,14
8,93
10,71
12,50
14,29
16,07
17,86
21,43
25,00

5
10
15
20
25
30
35
40
45
50
60
70

1,91
3,81
5,72
7,63
9,54
11,44
13,35
15,26
17,16
19,07
22,89
26,70

5
10
15
20
25
30
35
40
45
50
60
70

2,02
4,04
6,06
8,09
10,11
12,13
14,15
16,17
18,19
20,21
24,26
28,30

5
10
15
20
25
30
35
40
45
50
60
70

2,14
4,29
6,43
8,57
10,71
12,86
15,00
17,14
19,29
21,43
25,71
30,00

www.fstd.pt I T +351 210992389I Future,Science,Technology and Development. I Rua Fialho de Almeida n 14 2 Esq 1070-129 LISBOA PORTUGAL I info@fstd.pt

ENDOSMOSIS BOILER REGULATION TABLE


3P,19KW
(31,7A)

3P, 19kW
(32A)

3P, 20kW
(33,3A)

3P, 21kW
(35A)

3P, 22kW
(36,7A)

3P, 23kW
(38,3A)

3P, 24kW
(40A)

3P, 25kW
(41,7A)

3P, 26kW
(43,3A)

3P, 27kW
(45A)

3P, 28kW
(46,7A)

3P, 29kW
(48,3A)

3P, 30kW
(50A)

5
10
15
20
25
30
35
40
45
50
60
70

2,26
4,53
6,79
9,06
11,32
13,59
15,85
18,11
20,38
22,64
27,17
31,70

5
10
15
20
25
30
35
40
45
50
60
70

2,29
4,57
6,86
9,14
11,43
13,71
16,00
18,29
20,57
22,86
27,43
32,00

5
10
15
20
25
30
35
40
45
50
60
70

2,38
4,76
7,14
9,51
11,89
14,27
16,65
19,03
21,41
23,79
28,54
33,30

5
10
15
20
25
30
35
40
45
50
60
70

2,50
5,00
7,50
10,00
12,50
15,00
17,50
20,00
22,50
25,00
30,00
35,00

5
10
15
20
25
30
35
40
45
50
60
70

2,62
5,24
7,86
10,49
13,11
15,73
18,35
20,97
23,59
26,21
31,46
36,70

5
10
15
20
25
30
35
40
45
50
60
70

2,74
5,47
8,21
10,94
13,68
16,41
19,15
21,89
24,62
27,36
32,83
38,30

5
10
15
20
25
30
35
40
45
50
60
70

2,86
5,71
8,57
11,43
14,29
17,14
20,00
22,86
25,71
28,57
34,29
40,00

5
10
15
20
25
30
35
40
45
50
60
70

2,98
5,96
8,94
11,91
14,89
17,87
20,85
23,83
26,81
29,79
35,74
41,70

5
10
15
20
25
30
35
40
45
50
60
70

3,09
6,19
9,28
12,37
15,46
18,56
21,65
24,74
27,84
30,93
37,11
43,30

5
10
15
20
25
30
35
40
45
50
60
70

3,21
6,43
9,64
12,86
16,07
19,29
22,50
25,71
28,93
32,14
38,57
45,00

5
10
15
20
25
30
35
40
45
50
60
70

3,34
6,67
10,01
13,34
16,68
20,01
23,35
26,69
30,02
33,36
40,03
46,70

5
10
15
20
25
30
35
40
45
50
60
70

3,45
6,90
10,35
13,80
17,25
20,70
24,15
27,60
31,05
34,50
41,40
48,30

5
10
15
20
25
30
35
40
45
50
60
70

3,57
7,14
10,71
14,29
17,86
21,43
25,00
28,57
32,14
35,71
42,86
50,00

REGULATION INSTRUCTION
C
5
10
15
20
25
30
35
40
45
50
60
70

4,50
9,00
13,50
18,00
22,50
27,00
31,50
36,00
40,50
45,00
54,00
63,00

1. Install endosmosis boiler in accordance with assembly manual


2. Make sure that you have installed thermometer as close as possible to boiler outlet
3. Fill the whole heating system with heat carrier FLUID ECO
4. Free heating system from air and make heat carrier pressure in system about 1.5 bars
5. Turn on circulation pump and let heat carrier circulate in system
6. Turn on endosmosis boiler and measure temperature of heat carrier in boiler outlet
7. Measure Ampere consumption on boiler (it is recommended to do it in control panel)
8. Compare data you got to regulation table
9. If on boiler there are less Amperes than showed in table:
a. Add to heating system small portion (50ml) of FLUID POWER
b. Let FLUID POWER fully mix with heat carrier in heating system
c. Return to regulation instruction point 6
10. If on boiler there are exactly same Amperes as in table regulation is finished (it can be done on any heat carrier temperature)
11. If on boiler there are more Amperes than showed in table:
a. Partly replace heat carrier in system with clean FLUID ECO
b. Let clean FLUID ECO fully mix with heat carrier that is in heating system
c. Return to regulation instruction point 6

www.fstd.pt I T +351 210992389I Future,Science,Technology and Development. I Rua Fialho de Almeida n 14 2 Esq 1070-129 LISBOA PORTUGAL I info@fstd.pt

You might also like