You are on page 1of 28

xLPE

xLPE INSULATED
INSULATED HEAVY
HEAVY DUTY
DUTY CABLES
CABLES 650/1
650/1100
100 V.
V.

ISO

9001:2000
IS:694

P r o d u c t

R a n g e

L.T. Pvc & xlpe power cables with Copper /


aluminium conductor (650 / 1100 V. upto
4 core x 630 Sq. mm., 1 Core x 1000 Sq. mm.)

l.t.

pvc & xlpe control cables


(650 / 1100 V. upto
61 core x 1.5 & 2.5 Sq. mm.)

H.T.

XLPE Cables upto 19/33 KV.

Instrumentation

cables screened /
unscreened type in pvc / ldPE

Thermo-couple compensating & extension cables

frls / FR / HR / HFFR / hofr / Rubber / LDPE


power, control & instrumentation cables

Flexibles
Railway
Fire

& Housewires (Single & Multicore)

Signalling Cables

survival, Zero Halogen Cables

Telephone cables dry & jelly filled

Automobile
Mining

cables & Harnesses

/ welding rubber cables

epr / silicone / high temp. cables

Submersible

cables / Winding wires

Structured

Cables / co-axiel cables

Aerial

bunched cables

Lan Cat-5/5E cables

Optical

fibrE cables*

(*Under Development)

Wires & Cables

Polycab 650/1100 Volts XLPE Cables


C o n t e n t s

Contents

ISO 9000 Certificate

Advantage of XLPE Cables

Selection of Power Cables

Comparison of PVC & XLPE Cables

Technical Data

Table No.

1)

Conductor Resistance

2)

Comparative Current Ratings for PVC & XLPE Cables

3)

Comparative Short Circuit Ratings for PVC & XLPE Cables

4)

Capacitance Values

5)

Reactance Values

6)

Current Ratings / Rating Factors

7)

Group Rating Factors for Single Core Cables

8)

Group Rating Factors for Multi Core Cables

Weight and Dimension Data for 650 / 1100 Volts XLPE Insulated Cables

1)

1Core - Unarmoured and Armoured Aluminium & Copper Cables

12

2)

2Core - Unarmoured and Armoured Aluminium & Copper Cables

34

3)

3Core - Unarmoured and Armoured Aluminium & Copper Cables

56

4)

3.5Core- Unarmoured and Armoured Aluminium & Copper Cables

78

5)

4Core - Unarmoured and Armoured Aluminium & Copper Cables

9 10

6)

Multicore Control Cable with 1.5 Sq.mm. Copper Conductor

11

7)

Multicore Control Cable with 2.5 Sq.mm. Copper Conductor

12

Handling Storage & Laying of cables

Wires & Cables

Wires & Cables

I NTRODUCTION
POLYCAB has established its name in India and abroad for its quality and commitment to customer
satisfaction.
To meet ever increasing demand of POLYCAB cables, POLYCAB has put up a new state of the
art manufacturing unit at Daman (U.T.). The manufacturing of XLPE insulated heavy duty cables
is by adoptation of latest technology. The XLPE cables are manufactured as per IS-7098 Part-1 & Part2 and can be manufactured to meet the requirements of any international standards like BS 5467,
IEC-60502, DIN etc.
The XLPE compound used is obtained from reputed international sources meeting all required parameters.
The cables are manufactured in highly quality conscious environment with testing and inspection
done from raw-materials to finished cable stage. The assurance to the quality is further ensured by ISI
certification on cables and ISO-9002 certification by UL, USA.
XLPE Cables
The XLPE insulated heavy duty cables were introduced worldwide in mid sixties. These cables
have overcome the limitations of PVC Insulated Cables, such as thermal degradation, poor moisture
resistant and thermoplastic in nature.
The advantages of XLPE Insulated cables in comparision to those of PVC insulated cables are as under :(A) Technical Advantages :

Higher current rating, higher short Circuit Rating. Approx. 1.2 times that of PVC.

Thermosetting in nature.

Higher insulation resistance 1000 times more than PVC cables.

Better Resistance to surge currents.

Low Dielectric Losses.

Better resistance to chemicals and corrosion.

Longer service life.

Comparatively higher cable operating temperature 90oC and short circuit temperature 250oC.

(B) Commercial Advantages :


Lower laying cost because of comparatively smaller diameter of cable and lighter weight.*

Requiring less size of cable trays / supports.

One size lower cables can be used as compared to PVC insulated cable. **

* Density of XLPE is lower than PVC


** For longer cable length voltage drop shall be considered.

Wires & Cables

Selection Of Power Cables


Power cables are generally selected considering the application. However following factors are important
for selection of suitable cable construction required to transport electrical energy from one end to the
other.

Maximum operating voltage.

Insulation level.

Frequency.

Load to be carried.

Possible overloading duration & magnitude.

Route length and voltage drop.

Mode of insulation considering installation environment such as ambient & ground


temperature chemical & physical properties of soil.

Flame retardant properties.

Plant safety requirements.

All sizes of POLYCAB XLPE cables are designed to standard operating conditions in India and abroad
The standards adopted are considering the geographic / climatic conditions and general applications
of power for utilities, distribution and general purposes.
The cables are manufactured conforming to Indian & International specification for XLPE
Insulated cables. Customer specific requirements can also be met.
Polycab is manufacturers wide range of cables, it is therefore important that while placing
enquiries or orders, as much information as possible should be furnished, so that the enquiries and
orders are dealt quickly and efficiently .
Parameters required are as under

Voltage Grade 1100 Volts.

Relevant Indian Standard IS - 7098 (Part-1) 1988 or


International standard IEC - 60502 & BS - 5467, DIN.

Number of cores Single, Two, Three, Three & Half or Four Cores.

Conductor Size, wherever applicable size of reduced neutral conductor.

Conductor Material Copper/Aluminium.

Type of Insulation XLPE.

Type of Inner Sheathing PVC Wrapped/PVC Extruded.

Type of Armour Unarmoured/Strip Armoured/Wire Armoured/ Tape Armoured.

Type of Outer Sheath PVC/Flame Retardant/Flame Retardant Low Smoke/Zero Halogen (LSOH).

Length of cable required and drum lengths.

Wires & Cables

Table 1
** Conductor Technical Information for Single Core and Multicore cables conforming to IS-8130/1984
(Stranded Class-2) Copper & Aluminium Conductors.
Nominal
Minimum no. of wires
Size of
Conductor
Non
Compacted

Compacted
Round /Shaped
CU.

ALU.

CU.

ALU.

Max. D.C. Resistance


at 20oC
Plain
Aluminium
Copper
Ohm/Km

Ohm/Km

A.C. Resistance at 90oC


Plain
Copper

Aluminium

Ohm/Km

Ohm/Km

Sq.mm

1.5 *

12.1

18.10

15.5

23.17

2.5 *

7.41

12.10

9.48

15.50

4 *

4.61

7.41

5.90

9.48

6 *

3.08

4.61

3.94

5.90

10 *

1.83

3.08

2.34

3.94

16

1.15

1.91

1.47

2.44

25

0.727

1.20

0.930

1.54

35

0.524

0.868

0.671

1.11

50

19

19

0.387

0.641

0.495

0.82

70

19

19

12

12

0.268

0.443

0.343

0.567

95

19

19

15

15

0.193

0.320

0.247

0.410

120

37

37

18

15

0.153

0.253

0.196

0.324

150

37

37

18

15

0.124

0.206

0.159

0.264

185

37

37

30

30

0.0991

0.164

0.127

0.210

240

61

37

34

30

0.0754

0.125

0.0965

0.160

300

61

61

34

30

0.0601

0.100

0.0769

0.128

400

61

61

53

53

0.0470

0.0778

0.0602

0.100

500

61

61

53

53

0.0366

0.0605

0.0468

0.0774

630

91

91

53

53

0.0283

0.0469

0.0362

0.0600

800

91

91

53

53

0.0221

0.0367

0.0283

0.0470

1000

91

91

53

53

0.0176

0.0291

0.0225

0.0372

These sizes can be manufactured with solid conductor having single strand.

** Conductor meeting requirements of IEC-228 and BS 6360 can also be manufactured.

Wires & Cables

Table 2
Comparative Current Ratings of 650/1100 Volts Multicore heavy duty PVC Insulated Cables & XLPE Insulated Cables.
(3, 3.5 & 4 Core Unarmoured / Armoured PVC Sheathed Cables with Aluminium Conductor.

Nominal
3, 3.5 & 4 Core PVC Insulated & Sheathed
3, 3.5 & 4 Core XLPE Insulated & Sheathed
Size of
Cables as per IS - 1554 (Part-1) 1988
Cables as per IS - 7098 (Part-1) 1988
of cable
In Ground
In Air
Approx
Inground
In Air
Approx

Voltage Drop
Voltage Drop
Sq.mm
Amp
Amp
Mv / amp / mtr
Amp
Amp
Mv / amp / mtr











16
25
35
50
70
95
120
150
185
240
300
400

60
76
92
110
135
165
185
210
235
275
305
335

51
70
86
105
130
155
180
205
240
280
315
375

4.0
2.5
1.8
1.3
0.93
0.68
0.54
0.46
0.38
0.28
0.25
0.20

73
94
113
133
164
196
223
249
282
326
367
420

70
96
117
142
179
221
257
292
337
399
455
530

4.20
2.70
1.90
1.40
0.99
0.72
0.58
0.48
0.39
0.31
0.26
0.21

Table 3
Comparison of Short Circuit Rating for 1 Second duration for * PVC & XLPE Insulated Cables ** with Copper and Aluminium
Conductors. (Current in kAmps)
Nominal Size

Sq.mm

PVC Insulated
Copper
Aluminium

XLPE Insulated
Copper
Aluminium

0.173
0.283
0.46
0.690
1.15
1.84
2.88
4.03
5.75
8.05
10.90
13.80
17.30
21.30
27.60
34.50
46.00
57.50
72.50
92.00
115.00

0.21
0.36
0.57
0.86
1.40
2.30
3.60
5.00
7.10
10.00
13.60
17.10
21.40
26.40
34.30
42.90
57.10
71.40
90.00
114.30
142.90

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000



0.303
0.455
0.758
1.21
1.90
2.65
3.79
5.31
7.20
9.10
11.40
14.02
18.20
22.80
30.40
38.00
47.25
60.00
75.00

0.38
0.57
0.94
1.50
2.40
3.30
4.70
6.60
9.00
11.30
14.20
17.50
22.60
28.30
37.70
47.20
59.40
75.50
94.30

* PVC Type A Insulation as per IS-5831 84.


** PVC Cables as per IS-1554 (Part-1)-1988.
** XLPE Cables as per IS-7098 (Part-1)-1988.
1) Max. Conductor Temperature during

operation
PVC
XLPE

70oC
90oC

2) Max. Conductor Temperature During


Short circuit.

160oC

250oC

Formula relating Short Circuit Rating with duration


It = I sh

Where

t It = Short Circuit Rating for t Seconds.



t = duration in seconds
Ish = Short Circuit rating for 1 second.

Wires & Cables

Table 4
CAPACITANCE
Approximate Capacitance (Microfarads/km) 1.1 kV XLPE Cables.
Nominal Area Single Core
of Conductor

Two Core
Unarmoured Armoured
in sq. mm

1.5
0.19

0.051

2.5
0.24

0.058

4
0.29

0.065

6
0.34

0.071

10
0.43
0.32
0.081

16
0.51
0.38
0.088

25
0.49
0.38
0.089

35
0.57
0.44
0.096

50
0.58
0.46
0.098

70
0.63
0.51
0.10

95
0.73
0.59
0.11

120
0.74
0.61
0.11

150
0.73
0.61
0.11

185
0.69
0.59
0.11

240
0.74
0.64
0.11

300
0.80
0.69
0.12

400
0.83
0.70
0.12

500
0.83
0.71
0.12

630
0.87
0.75
0.11

800
0.92
0.78


1000
0.94
0.81

Three,Three &
Half and
Four Core
0.15
0.18
0.22
0.25
0.31
0.36
0.41
0.47
0.50
0.53
0.61
0.63
0.64
0.65
0.66
0.67
0.67
0.69
0.73

Table 5
REACTANCE
Approximate Reactance At 50 Hz (Ohm/km) 1.1 kV XLPE Cables.
Nominal Area Single Core
of Conductor

Unarmoured Armoured
in sq. mm

1.5
0.155


2.5
0.142


4
0.132


6
0.123


10
0.114
0.134

16
0.108
0.125

25
0.103
0.120

35
0.0986
0.114

50
0.0937
0.108

70
0.0900
0.102

95
0.0865
0.100

120
0.0841
0.0968

150
0.0839
0.0941

185
0.0836
0.0932

240
0.0813
0.0900

300
0.0795
0.0881

400
0.0787
0.0873

500
0.0779
0.0859

630
0.0785
0.0843

800
0.0755
0.0826

1000
0.0752
0.0825

Multi Core
0.107
0.0985
0.0927
0.0884
0.0837
0.0808
0.0805
0.0783
0.0750
0.0740
0.0724
0.0712
0.0716
0.0718
0.0710
0.0705
0.0704
0.0702
0.0698

Wires & Cables

C U R RENT R A TING S
POLYCAB RECOMMENDATIONS FOR CURRENT RATINGS:
The current rating of power cable is defined by the maximum intensity of current (amperes) which can
flow continuously through the cable, under permanent loading conditions, without any risk of damaging
the cable or deterioration of its electrical properties.
The value given in the tables are valid for one circuit in a three phase system under conditions specified.
For grouping cables rating factors must be used.
The current carrying capacities mentioned in POLYCAB technical data are intended as a guide, to assist
operating engineers in selecting cables for safety and reliability.
Basic assumptions and conditions of installation :

Ambient Ground Temperature :

30 C.

Ambient Air Temperature

40 C.

Depth of cable burial

750 mm.

Thermal resistivity of soil

150 C. Cm/W

Max. conductor Temperature


for Continuous Operation

90 C.

Max. Conductor Temperature


for Short Circuit

250 C.

Single core cables are installed as indicated in the table. Spacing between cables in flat formation
is as indicated.
For three and four core cables, it is usual to assume the same current carrying capacity for four cores
cables as for three core cables. Our calculated values are based actually on three cores cables. These
values are suitable with enough accuracy also for four core cables in most cases. Only for large four
core cables in air the values may be found to be too conservative, due to the large cable surface and
consequent high heat dissipation factor.
To obtain the maximum current carrying capacity of a cable operating at different conditions from the
standard. Various rating factors are to be multiplied, as follows :Ia = K x Is

in amperes

Where ;

I a : Current rating at actual operating conditions (amperes)

I s : Current rating at standard operating conditions (amperes)

K : Rating factor as, applicable.

Wires & Cables

R A TING FACTOR S
1)

For Air and Ground Temperature.


A. Rating factors for variation in ambient air temperature

Ambient Temp (C)

25

30

35

40

45

50

Rating Factors

1.14

1.10

1.04

1.00

0.95

0.90

B. Rating factors for variation in ground temperature


Ground Temp (C)

15

20

25

30

35

40

Rating Factors

1.12

1.08

1.03

1.00

0.96

0.91

2)

For depth of Laying (cables laid direct in the ground).


Depth of laying

Size

Cm

Upto 25 mm

Above 25 mm2 Upto 300 mm2

Above 300 mm2

75

1.0

1.00

1.00

90

0.99

0.98

0.97

105

0.98

0.97

0.96

120

0.97

0.96

0.95

150

0.96

0.94

0.92

180 or more

0.95

0.93

0.91

3)


For variation in thermal resistivity of soil (two and three and multicore
cables laid direct in the ground).


Nominal area of

conductor mm2

100
















1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400

1.10
1.10
1.10
1.10
1.10
1.12
1.14
1.15
1.15
1.15
1.15
1.17
1.17
1.18
1.18
1.18
1.19

Two cables touching for values of Thermal Resistivity of soil in C


cm / W
120
150
200
250
1.05
1.05
1.05
1.05
1.06
1.06
1.08
1.08
1.08
1.08
1.08
1.09
1.09
1.09
1.09
1.09
1.10

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.92
0.92
0.92
0.92
0.92
0.91
0.91
0.91
0.91
0.90
0.90
0.90
0.90
0.89
0.89
0.89
0.89

0.86
0.86
0.86
0.86
0.85
0.84
0.84
0.84
0.84
0.83
0.83
0.82
0.82
0.81
0.81
0.81
0.81

300
0.81
0.81
0.81
0.81
0.80
0.79
0.78
0.77
0.77
0.76
0.76
0.76
0.75
0.75
0.75
0.75
0.75

10

Wires & Cables

Group R ATING FACTOR S


FOR Single Core Cables
A)

Cables laid direct in the ground in horizontal formation.

No. of Trefoils in

Distance between Trefoils

Group

Touching

15 cm

30 cm

45 cm

0.78

0.81

0.85

0.88

0.68

0.71

0.77

0.81

0.61

0.65

0.72

0.76

0.56

0.61

0.68

0.73

B)

Cables laid in ducts in horizontal formation.


No. of Trefoils in

Distance between Trefoils

Group

Touching

45 cm

60 cm

0.87

0.90

0.91

0.79

0.83

0.86

0.74

0.79

0.82

0.71

0.76

0.80

C) Cables laid on Racks / Trays in covered trench with having restricted air circulation,
Trefoils are separated by two cable diameter horizontally and the trays are in tiers having
30 cm distance.

D)

No. racks / trays in

No. of Trefoils in Horizontal Formation

tiers

0.95

0.90

0.88

0.90

0.85

0.83

0.88

0.83

0.81

0.86

0.81

0.79

as above C. but cables lad in open air.


No. racks / trays in

No. of Trefoils in Horizontal Formation

tiers

0.98

0.96

0.95

0.93

0.94

0.92

0.93

0.90

11

Wires & Cables

FOR multi Core Cables


A) Cables laid on cable trays exposed to air, the cables spaced by one cable diameter and
trays are in tiers spaced by 30 cm. The clearanc between the wall and the cable is 25 mm.





No. of cables trays in


tier
1
2
3
6

1
1
1
1
1

Distance between Trefoils

2
0.98
0.95
0.94
0.93

3
0.96
0.93
0.92
0.90

6
0.93
0.90
0.89
0.87

9
0.92
0.89
0.88
0.86

B) Cables laid inside concrete trench with removable covers on cable trays having restricted
circulation. The cables spaced by one cable diameter and trays are in tiers spaced by 300 mm. The
clearance of the cable from the wall is 25 mm.





No. of cables trays in


tier
1
2
1
0.95
0.90
2
0.90
0.85
3
0.88
0.83
6
0.86
0.81

No. of cables
3
0.88
0.83
0.81
0.79

6
0.85
0.81
0.79
0.77

9
0.84
0.80
0.78
0.76

C) Cables laid on cable trays exposed to air, the cable touching and trays are in tiers spaced by
30 cm. The clearance between the wall and the cable is 25 mm.

No. of cables trays

1
2



1
2
3
6

1
1
1
1

No. of cables per tray


3

0.84
0.80
0.78
0.76

0.80
0.76
0.74
0.72

D)

Cables laid direct in ground in horizontal formation.

No. of cables in Distance of cables


Group
Touching
15 cm
30 cm

2
3
4
5
6

0.79
0.69
0.62
0.58
0.54

0.82
0.75
0.69
0.65
0.61

0.87
0.79
0.74
0.72
0.69

E)

Cables laid in single way ducts / pipes in horizontal formation.

No. of cables in Distance of cables


Group
Touching
30 cm
45 cm
2
0.88
0.90
0.92
3
0.82
0.84
0.87
4
0.77
0.80
0.84
5
0.74
0.78
0.82
6
0.71
0.76
0.81

0.75
0.71
0.70
0.68

0.73
0.69
0.68
0.66

45 cm
0.90
0.83
0.79
0.76
0.75

60 cm
0.94
0.89
0.87
0.85
0.84

10

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

800

1000

Solid

do

do

do

do

do

do

do

do

do

do

do

do

do

do

do

Stranded

Stranded

Solid

Stranded

Solid

Stranded

2.8

2.6

2.4

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

0.7

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

52.0

46.0

40.0

36.0

33.0

28.5

26.0

23.5

21.5

19.0

17.5

16.0

14.0

13.0

12.0

10.0

9.5

9.0

8.5

8.0

8.0

7.5

3350

2730

2100

1650

1385

1075

900

710

600

470

385

310

240

180

155

115

90

80

75

70

65

60

3.3

3.1

2.8

2.6

2.4

2.1

2.0

1.9

1.7

1.5

1.4

1.4

1.3

1.2

1.2

1.0

1.0

1.0

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

* Delivery Length tolerance is 5% Length more than normal as per customer request.

The above data is approximate and subject to manufacturing tolerance.

54.0

46.5

40.5

37.5

34.0

30.0

27.5

25.0

23.0

22.0

21.0

3963

3150

2525

2090

1725

1350

1100

900

750

660

560

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

58.0

49.5

43.0

39.5

36.5

31.5

29.0

26.5

24.5

23.5

22.0

19.0

17.0

15.0

14.0

13.0

4475

3450

2800

2300

1925

1475

1215

1000

850

745

640

480

380

310

260

220

Nominal Form of Nominal Minimum


Unarmoured Cable
Nominal
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
size of Conductor Thickness Thickness Nominal Approx.
Approx. Thickness Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Conductor Circular
of XLPE
of PVC Thickness Overall Weight of of XLPE Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight



Insulation
Inner
of PVC
Diameter
Cable insulation for
of
of PVC Diameter
Cable
of
of PVC Diameter
of



for U/A
Sheath
Outer
of Cable

Armoured Aluminium Outer
of

Aluminium Outer
of
Cable








Cable
Flat. Strip
Sheath Cable

Round Wire Sheath Cable
Sq. mm.

mm
mm
mm
mm
Kg./Km
mm
mm
mm mm
Kg./Km
mm
mm mm
Kg./Km

Weight & Dimensions

98

73

53

53

39

39

31

31

650 1050

600 890

557 814

490 693

431 596

376 501

332 433

286 360

253 309

225 268

198 230

166 187

135 150

114 121

96

76

59

59

44

44

36

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

Amps. Amps.
36

* Normal
Delivery
Length.

Current Rating
In In Air
Ground.

POLycab single core aluminium conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988
Table - WD 1 1100 Volts

12
Wires & Cables

185

240

300

400

500

630

800

1000

Solid

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Standed

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Solid

Stranded

2.8

2.6

2.4

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

52

46.0

40.0

36.0

33.0

28.5

26.0

23.5

21.5

19.0

17.5

16.0

14.0

13.0

12.0

10.0

9.5

8.5

8.0

8.0

7.5

9850

7900

6250

5020

4035

3050

2450

1900

1550

1250

1010

750

550

420

325

220

170

125

115

95

91

3.3

3.1

2.8

2.6

2.4

2.1

2.0

1.9

1.7

1.5

1.4

1.4

1.3

1.2

1.2

1.0

1.0

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5% Length more than normal as per customer request.

150

70

50

95

35

120

25

16

10

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

54.0

46.5

40.5

37.5

34.0

30.0

27.5

25.0

23.0

22.0

21.0

10150

8100

6425

5180

4200

3200

2580

2040

1680

1400

1150

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

58.0

49.5

43.0

39.5

36.5

31.5

29.0

26.5

24.5

23.5

22.0

19.0

17.0

16.0

14.0

13.0

12.0

10660

8400

6700

5400

4400

3325

2700

2140

1780

1485

1325

910

690

525

415

315

245

Nominal Form of Nominal Minimum


Unarmoured Cable
Nominal
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
size of Conductor Thickness Thickness Nominal Approx.
Approx. Thickness Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Conductor Circular
of XLPE
of PVC Thickness Overall Weight of of XLPE Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight



Insulation
Inner
of PVC
Diameter
Cable insulation for
of
of PVC Diameter
Cable
of
of PVC Diameter
of



for U/A
Sheath
Outer
of Cable

Armoured Aluminium Outer
of

Aluminium Outer
of
Cable





Sheath


Cable
Flat. Strip
Sheath Cable

Round Wire Sheath Cable
Sq. mm.

mm
mm
mm
mm
Kg./Km
mm
mm
mm mm
Kg./Km
mm
mm mm
Kg./Km

Weight & Dimensions

98

72

53

53

42

42

723 1063

660 945

564 825

570 708

480 660

450 570

414 510

366 444

336 384

300 336

264 294

228 246

186 198

156 156

132 132

102

78

59

59

47

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

Amps. Amps.
47

* Normal
Delivery
Length.

Current Rating
In In Air
Ground

POLycab single core copper conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988
Table - WD 2 1100 Volts

Wires & Cables

13

Solid

10

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

2.4

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

Weight & Dimensions

3.6

3.4

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

61.5

55.5

49.0

43.5

39.5

35.5

32.0

28.5

26.5

23.0

21.0

19.0

17.0

14.0

16.0

15.0

14.0

13.5

13.0

12.5

5000

4000

3100

2360

1900

1510

1215

1050

900

675

510

410

330

225

225

205

180

170

150

140

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2.68

2.52

2.36

2.04

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

62.5

56.5

51.0

45.5

41.0

37.0

34.0

30.5

28.0

25.5

22.5

20.0

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

6050

5000

4000

3200

2600

2200

1750

1500

1300

1050

820

690

600

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

3.15

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

1.40

1.40

2.84

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

67.5

61.5

54.4

49.0

45.0

40.0

36.0

33.0

30.5

27.0

24.0

22.0

20.0

17.0

18.0

17.0

16.5

15.5

15.5

14.5

8560

7000

5300

4400

3700

2750

2250

2000

1750

1325

1050

910

790

570

565

545

485

470

430

400

Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Nominal
Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Thickness
Overall
Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable
Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.



* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Solid

Stranded

Solid

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal

size of
Conductor






Sq. mm.

592

523

481

444

400

344

300

262

238

200

169

138

112

88

69

69

50

50

40

40

Amps.

786

678

525

456

406

344

300

262

231

188

156

124

98

74

59

59

44

44

34

34

Amps.

Current Rating
In
In Air
Ground

POLycab TWO core aluminium conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988
Table - WD 3
1100 Volts

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length.

14
Wires & Cables

Solid

10

16

25

35

50

70

95

120

150

185

240

300

400

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

Weight & Dimensions

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

49.0

43.5

39.5

35.5

32.0

28.5

26.5

23.0

21.0

19.0

17.0

14.0

16.0

14.0

13.5

13.0

12.5

8050

6075

4870

3800

3070

2535

2075

1540

1120

840

640

425

300

225

210

175

165

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2.36

2.04

1.88

1.72

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

51.0

45.5

41.0

37.0

34.0

30.5

28.0

25.5

22.5

20.0

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

8950

6910

5575

4490

3600

2985

2475

1910

1435

1025

910

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2.5

2.5

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

54.4

49.0

45.0

40.0

36.0

33.0

30.5

27.0

24.0

22.0

20.0

17.0

18.0

16.5

15.5

15.5

14.5

10250

9010

7370

5040

4100

3485

2925

2200

1670

1350

1100

770

740

610

564

525

480

Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Nominal
Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Thickness
Overall
Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable
Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.



* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Solid

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal

size of
Conductor






Sq. mm.

1100 Volts

Table - WD 4

612

562

506

438

388

344

300

256

206

175

144

113

88

63

63

51

51

Amps.

662

581

512

438

381

331

288

244

194

150

131

98

75

56

56

44

44

Amps.

Current Rating
In
In Air
Ground

POLycab TWO core copper conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length.

Wires & Cables

15

240

300

400

500

630

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Solid

Stranded

Solid

2.4

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.7

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

3.8

3.6

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

72.0

66.0

59.5

51.5

48.5

43.5

38.5

34.5

32.5

29.0

24.5

21.5

20.0

18.0

18.0

17.0

16.0

15.5

15.5

14.0

7550

6000

4760

3750

3000

2380

1900

1525

1250

990

700

575

460

310

230

220

190

170

160

140

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2.84

2.68

2.52

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

73.0

67.0

58.5

53.0

49.0

44.5

40.5

35.5

33.5

30.0

25.5

23.0

20.5

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

8700

6900

5700

4500

3700

2500

2100

2050

1735

1425

1100

900

770

530

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

4.00

3.15

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

1.40

3.00

2.84

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

78.0

73.0

65.0

57.5

53.0

48.5

43.5

39.5

37.5

32.0

27.5

25.0

23.0

21.0

19.0

18.0

17.0

16.0

16.0

15.0

12500

9550

7900

5900

5100

4200

3200

2700

2300

1950

1400

1150

990

750

680

640

580

530

510

460

Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Nominal
Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Thickness
Overall
Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable
Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.



* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

185

70

150

50

35

95

25

120

16

10

10

Solid

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal

size of
Conductor






Sq. mm.

Weight & Dimensions

529

470

418

367

326

282

249

223

196

164

133

113

94

73

57

57

43

43

34

34

Amps.

707

612

530

455

399

337

292

257

221

179

142

117

96

70

67

67

50

50

31

31

Amps.

Current Rating
In
In Air
Ground

POLycab three core aluminium conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988
Table - WD 5 1100 Volts

250

250

500

500

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length.

16
Wires & Cables

Solid

10

16

25

35

50

70

95

120

150

185

240

300

400

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

Weight & Dimensions

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

59.5

51.5

48.5

43.5

38.5

34.5

32.5

29.0

24.5

21.5

20.0

18.0

18.0

16.0

15.5

15.5

14.0

12200

9310

7450

5810

4760

3750

3010

2290

1620

1225

920

425

415

300

280

235

210

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

2.52

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

-NA-

-NA-

-NA-

-NA-

-NA-

58.5

53.0

49.0

44.5

40.5

35.5

33.5

30.0

25.5

23.0

20.5

18.5

-NA-

-NA-

-NA-

-NA-

-NA-

13125

10060

8150

6385

5280

4320

3500

2720

2020

1550

1235

825

-NA-

-NA-

-NA-

-NA-

-NA-

3.15

2.50

2.50

2.50

2.00

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

65.0

57.5

53.0

48.5

43.5

39.5

37.5

32.0

27.5

25.0

23.0

21.0

19.0

17.0

16.0

16.0

15.0

15320

11460

9550

7630

5980

4920

4060

3250

2320

1800

1450

1040

865

680

640

580

530

Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Nominal
Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Thickness
Overall
Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable
Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.



* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Solid

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal

size of
Conductor






Sq. mm.

1100 Volts

Table - WD 6

510

462

414

360

324

288

252

210

174

144

119

92

72

54

54

43

43

Amps.

546

480

426

366

318

276

240

198

162

132

108

79

62

47

47

36

36

Amps.

Current Rating
In
In Air
Ground

POLycab three core copper conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988

250

250

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length.

Wires & Cables

17

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

25/16

35/16

50/25

70/35

95/50

120/70

150/70

185/95

240/120

300/150

400/185

500/240

Weight & Dimensions

2.2

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

1.7

1.6

1.4

1.2

1.1

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

3.6

3.4

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

72.5

64.0

56.0

52.5

46.5

41.0

37.5

35.0

31.0

27.5

24

22

6500

5250

4000

3200

2550

2000

1650

1400

1100

800

625

525

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.80

2.68

2.52

2.20

2.04

1.88

1.72

1.72

1.56

1.56

1.40

1.40

1.40

73.5

65.0

57.0

53.5

47.5

42.0

39.0

36.0

32.0

28.0

25.0

23.0

7600

6150

4950

4100

3250

2650

2300

1900

1600

1240

980

850

3.15

3.15

2.5

2.5

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

2.84

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

77.0

70.0

61.0

56.0

50.0

45.0

41.0

38.0

34.0

29.5

26.5

25.5

10000

8300

6400

5450

4500

3350

2800

2450

2050

1500

1200

1050

Nominal
Minimum
Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Thickness
Thickness Nominal Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
of XLPE
of PVC Thickness Overall Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
Insulation
Inner
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Main / Neutral
Sheath
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable


Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.



* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal
size of
Conductor






Sq. mm.

1100 Volts

Table - WD 7

470

418

367

326

282

249

223

196

164

133

113

94

Amps.

612

530

455

399

337

292

257

221

179

142

117

96

Amps.

Current Rating
In
In Air
Ground

POLycab three and half core aluminium conductor, XLPE insulated, unarmoured &
Armoured cable conforming to is 7098 part-1/1988

250

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

500

Mtrs.

* Normal
Delivery
Length.

18
Wires & Cables

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

25/16

35/16

50/25

70/35

95/50

120/70

150/70

185/95

240/120

300/150

400/185

Weight & Dimensions

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

1.6

1.4

1.2

1.1

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

0.3

0.3

3.4

3.0

2.8

2.6

2.4

2.2

2.2

2.2

2.0

2.0

2.0

65.0

57.0

54.0

48.0

43.0

39.0

35.0

31.0

27.5

24.0

22.0

13820

10500

8400

6575

5220

4315

3475

2620

1875

1370

1080

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.80

2.52

2.20

2.04

1.88

1.72

1.72

1.56

1.56

1.40

1.40

1.40

66

58

55

50

44

40

36

32

28

25

23

14720

11500

9300

7275

5870

4960

8975

3110

2325

1725

1410

3.15

2.5

2.5

2.5

2.0

2.0

2.0

2.0

1.6

1.6

1.6

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

70.0

61.0

56.0

50.0

45.0

41.0

37.5

34.0

29.0

26.0

24.0

16875

12400

10650

8520

6570

5460

4525

3560

2580

1950

1610

Nominal
Minimum
Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Thickness
Thickness Nominal Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
of XLPE
of PVC Thickness Overall Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
Insulation
Inner
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Main / Neutral
Sheath
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable


Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.



* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Stranded

Stranded

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal
size of
Conductor






Sq. mm.

1100 Volts

Table - WD 8

510

462

414

360

324

288

252

210

174

144

119

Amps.

546

480

426

366

318

276

240

198

162

132

108

Amps.

Current Rating
In
In Air
Ground

POLycab three and half core copper conductor, XLPE insulated, unarmoured &
Armoured cable conforming to is 7098 part-1/1988

250

250

250

-do-

-do-

-do-

-do-

-do-

-do-

-do-

500

Mtrs.

* Normal
Delivery
Length.

Wires & Cables

19

240

300

400

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Solid

Stranded

Solid

2.0

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.7

0.7

0.6

0.5

0.5

0.5

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

Weight & Dimensions

3.6

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

65.5

58.0

52.5

46.5

42.0

37.5

33.5

30.5

26.0

23.5

21.0

17.5

18.5

18.0

17.5

16.5

16.0

15.0

6000

4600

3700

2800

2280

1850

1530

1200

875

680

550

350

260

250

215

200

180

160

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2.68

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

66.5

59.5

54.0

48.0

43.5

39.0

35.0

32.0

28.0

25.0

23.0

20.0

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

7000

5600

4700

3650

3000

2600

2100

1700

1280

1050

940

715

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

3.15

3.15

2.50

2.50

2.50

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

1.40

2.84

2.52

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

71.5

64.5

57.5

52.0

47.0

42.0

38.0

34.0

29.5

26.5

25.0

21.0

20.5

19.0

18.5

17.5

17.5

16.5

9500

7850

6050

5000

4175

3250

2775

2175

1640

1325

1150

895

765

700

625

580

560

510

Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Nominal
Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Thickness
Overall
Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable
Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.



* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

185

70

150

50

35

95

25

120

16

10

10

Solid

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal

size of
Conductor






Sq. mm.

418

367

326

282

249

223

196

164

133

113

94

73

57

57

43

43

34

34

Amps.

530

455

399

337

292

257

221

179

142

117

96

70

67

67

50

50

31

31

Amps.

Current Rating
In
In Air
Ground

POLycab four core aluminium conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988
Table - WD 9 1100 Volts

250

250

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

500

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length

20
Wires & Cables

300

Solid

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

Stranded

1.8

1.7

1.6

1.4

1.2

1.1

1.1

1.0

0.9

0.9

0.7

0.7

0.7

0.7

0.7

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.7

0.6

0.5

0.5

0.5

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

Weight & Dimensions

3.2

3.0

2.8

2.6

2.4

2.2

2.2

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

58.0

52.5

46.5

42.0

37.5

33.5

30.5

26.0

23.5

21.0

17.5

18.5

17.5

16.5

16.0

15.0

12025

9650

7380

6000

4825

3880

2925

2110

1550

1170

750

510

365

350

280

260

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.8

-NA-

-NA-

-NA-

-NA-

-NA-

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.56

1.40

1.40

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

59.5

54.0

48.0

43.5

39.0

35.0

32.0

28.0

25.0

23.0

20.0

-NA-

-NA-

-NA-

-NA-

-NA-

13025

10340

8225

6710

5575

4450

3430

2510

1915

1520

1050

-NA-

-NA-

-NA-

-NA-

-NA-

3.15

2.50

2.50

2.50

2.00

2.00

2.00

1.60

1.60

1.60

1.60

1.40

1.40

1.40

1.40

1.40

2.52

2.36

2.20

2.04

1.88

1.72

1.56

1.56

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

64.5

57.5

52.0

47.0

42.0

38.0

34.0

29.5

26.5

25.0

21.0

20.5

18.5

17.5

17.5

16.5

15275

12000

9580

7890

6225

5125

3900

2875

2190

1770

1275

1010

775

730

660

610

Unarmoured Cable
Formed Wire / Strip Armoured Cable
Round Wire Armoured Cable
Nominal
Approx.
Approx. Nominal Minimum Approx.
Approx. Nominal Minimum Approx.
Approx.
Thickness
Overall
Weight of Dimension Thickness Overall Weight of Dimension Thickness Overall
Weight
of PVC
Diameter
Cable
of
of PVC
Diameter
Cable
of GI
of PVC Diameter
of
Outer
of Cable

GI Flat
Outer
of

Round
Outer
of
Cable
Sheath


Strip
Sheath
Cable

Wire
Sheath
Cable
mm
mm
Kg./Km
mm
mm
mm
Kg./Km
mm
mm
mm
Kg./Km

T he above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

240

70

50

185

35

25

150

16

10

95

120

Solid

Stranded

Form of
Conductor
Circular
Shaped


mm

Nominal

size of
Conductor






Sq. mm.

1100 Volts

Table - WD 10

POLycab four core copper conductor, XLPE insulated, unarmoured &


Armoured cable conforming to is 7098 part-1/1988

462

414

360

324

288

252

210

174

144

119

92

72

54

54

43

43

Amps.

480

426

366

318

276

240

198

162

132

108

79

62

47

47

36

36

Amps.

Current Rating
In
In Air
Ground

250

250

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

500

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length

Wires & Cables

21

Solid & Strandes $

19

21

24

27

30

33

37

44

52

61

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

2.2

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

31.0

29.0

28.0

25.0

24.0

23.5

23.0

22.5

20.5

19.5

18.5

18.0

17.5

17.0

15.5

14.5

13.5

13.5

12.5

11.5

10.5

10.0

1500

1300

1150

975

910

820

750

665

600

540

475

430

390

340

315

280

260

250

225

200

160

140

Unarmoured Cable
Nominal
Approx.
Approx.
Thickness
Overall
Weight of
of PVC
Diameter
Cable
Outer
of Cable

Sheath


mm
mm
Kg./Km

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

4 x 0.80

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

1.56

1.56

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

1.40

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

32.0

30.5

28.5

26.0

25.0

24.0

23.5

23.0

21.0

20.0

19.0

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

1950

1700

1500

1325

1225

1125

1050

1000

900

815

750

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Formed Wire / Strip Armoured Cable


Nominal
Minimum
Approx.
Approx.
Dimension Thickness
Overall
Weight of
of
of PVC
Diameter
Cable
GI Flat
Outer
of

Strip
Sheath
Cable

mm
mm
mm
Kg./Km

Weight & Dimensions

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

Nominal
Dimension
of GI
Round
Wire
mm

$ The Weight and Dimensions of Cables with Stranded conductor will be comparatively more than that of Solid conductor,whereas all other parameters are same.
The above data is approximate and subject to manufacturing tolerance.
* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

14

16

10

12

Number

of
Cores






No. s

Table - WD 11

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.24

1.24

34.5

32.0

30.5

28.0

27.0

26.0

25.5

25.0

23.0

22.0

21.0

20.0

19.0

18.5

17.5

16.5

15.5

15.5

14.5

13.5

13.0

12.5

Round Wire Armoured Cable


Minimum
Approx.
Thickness
Overall
of PVC
Diameter
Outer
of
Sheath
Cable
mm
mm

2550

2050

1850

1550

1475

1400

1330

1250

1150

1010

925

825

720

655

630

580

520

500

465

415

390

370

Kg./Km

Approx.
Weight
of
Cable

10

11

11

12

12

13

13

14

15

16

16

17

18

19

20

21

22

24

25

25

33

Amps.

10

10

11

11

12

12

13

14

14

15

16

17

18

18

19

21

22

22

29

Amps.

Current Rating
In
In Air
Ground

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length.

POLycab 1100 Volts multicore control cable with solid copper conductor of size 1.5 sq. mm XLPE
insulated, unarmoured in Armoured cable conforming to is 7098 part-1/1988

22
Wires & Cables

Solid & Stranded $

10

12

14

16

19

21

24

27

30

33

37

44

52

61

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

-do-

0.7

Nominal
Thickness
of XLPE
Insulation


mm

0.4

0.4

0.4

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Minimum
Thickness
of PVC
Inner
Sheath

mm

2.2

2.2

2.2

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

1.8

35.0

33.5

32.0

28.0

27.0

26.0

25.5

24.5

22.5

21.5

20.5

19.0

18.0

17.5

16.5

16.0

15.0

15.0

14.0

13.0

12.0

11.5

2150

1950

1650

1350

1250

1150

1050

950

860

770

680

625

550

475

450

400

360

340

300

260

220

185

Unarmoured Cable
Nominal
Approx.
Approx.
Thickness
Overall
Weight of
of PVC
Diameter
Cable
Outer
of Cable

Sheath


mm
mm
Kg./Km

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.24

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

36.0

34.5

33.0

29.5

28.5

27.5

26.5

25.5

23.5

22.5

21.5

20.0

19.5

19.0

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

2625

2350

2100

1710

1630

1550

1350

1250

1140

1025

920

850

760

700

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

-NA-

Formed Wire / Strip Armoured Cable


Nominal
Minimum
Approx.
Approx.
Dimension Thickness
Overall
Weight of
of
of PVC
Diameter
Cable
GI Flat
Outer
of

Strip
Sheath
Cable

mm
mm
mm
Kg./Km

Weight & Dimensions

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

Nominal
Dimension
of GI
Round
Wire
mm

1.56

1.56

1.56

1.56

1.56

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.40

1.24

1.24

1.24

1.24

1.24

1.24

1.24

39.0

37.5

35.5

31.5

30.5

29.0

28.5

27.5

25.5

24.5

23.5

22.0

21.5

21.0

19.5

18.0

16.5

16.5

15.5

14.5

14.0

13.5

Round Wire Armoured Cable


Minimum
Approx.
Thickness
Overall
of PVC
Diameter
Outer
of
Sheath
Cable
mm
mm

$ The Weight and Dimensions of Cables with Stranded conductor will be comparatively more than that of Solid conductor, whereas all other parameters are same.
The above data is approximate and subject to manufacturing tolerance.
* Delivery Length tolerance is 5 %. Length more than normal as per customer request.

Number

of
Cores






No. s

Table - WD 12

3400

2900

2600

2080

1950

1760

1625

1500

1350

1250

1160

1050

975

875

800

700

625

600

525

500

425

380

Kg./Km

Approx.
Weight
of
Cable

12

13

14

15

15

16

16

17

18

19

20

21

22

24

25

26

27

29

31

34

34

39

Amps.

11

12

12

13

14

14

16

16

16

17

18

19

20

21

22

24

25

26

28

30

30

32

Amps.

Current Rating
In
In Air
Ground

500

500

500

500

500

500

500

500

500

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

Mtrs.

* Normal
Delivery
Length.

POLycab
1100 Volts multicore control cable with solid copper conductor of size 2.5 sq. mm XLPE

insulated,
unarmoured and in Armoured cable conforming to is 7098 part-1/1988

Wires & Cables

23

24

Wires & Cables

HANDLING STORAGE AND LAYING OF POLYCAB XLPE CABLES


A) HANDLING : 1) The cable with or without drum shall not be thrown or dropped on the ground
from the carriers such as trucks or railway wagons, during unloading.
2) The cable drum shall be unloaded with the help of cranes or fork lifts or using a
proper ramp having inclination 1:3 to 1:4 in order to avoid mechanical damage
to the outer layers of cables.
3) The cable drums shall be lifted or stored with its flanges always vertical.
4) The cable drum shall be rolled in the direction of arrow only, in order to avoid
loosening of cable winding. The drum shall not be rolled on rocky, uneven
surface and for longer distances, it may damage the drum and cable.
B) STORAGE : 1) The cables shall be stored in dry covered places having concrete / firm surface
capable of bearing the load of drum.
2) The cable ends shall be sealed properly in order to prevent moisture ingress.
3) Antirodent / termite repulsion treatment shall be applied to the site where
the drum are stored for very long period of time.
C) LAYING

: 1) Polycab recommends the laying and installation of cables as per IS:1255/84.

2) Care shall be taken during laying to avoid sharp bending, and twisting .
3) Cable shall be un wound from the drum by lifting the drum on the center
shaft supported both ends with suitable jacks / stands.
4) Under no circumstances the cable winding shall be lifted off a coil or drum
lying flat at the flanges. This would cause serious twist and damages.
5) Suitable protection shall be provided to the cables against mechanical damages,
it includes covers, pipes etc.
D) Recommended minimum bending radius for 1100 volts heavy duty cables :

Single Core -

MultiCore

15 x D

Where D= Diameter of cable in mm

12 x D

E) Recommended safe Pulling force with stockings :


a) For Unarmoured Cable : P = 5 D2
b) For Armoured Cable

Where P= Pulling Force

: P = 9 D2

D= Diameter of cable in mm

F) Recommended safe pulling force when pulled with pulling eye :


a) For Aluminium Conductors : 30 N/mm2

b) For Copper Condxuctor


Note : All figures given in various tables are indicative only.

: 50 N/mm2

Polyc ab Wires PVt. Ltd.


An iso 9001:2000 company