Liquid ring vacuum pumps

LEH 2200, LEH 3000

Pressure range: Suction volume flow:


CONSTRUCTION TYPE

33 to 1013 mbar 730 to 3550 m/h

SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and robust construction with the following particular features: non-polluting due to nearly isothermal compression oil-free, as no lubrication in the working chamber handling of nearly all gases and vapours small quantities of entrained liquid can be handled easy maintenance and reliable operation low noise and nearly free from vibration wide choice of material, therefore applicable nearly everywhere Internal service liquid return; adjustable from the outside protection against cavitation as standard incorporated dirt drain incorporated central drain no metallic contact of the rotating parts The SIHI liquid ring vacuum pumps LEH are single-stage ones.

NOTE During operation the pump must continuously be supplied with service liquid, normally water, in order to eliminate the heat resulting from the gas compression and to replenish the liquid ring, because part of the liquid is leaving the pump together with the gas. This liquid can be separated from the gas in a liquid separator (see catalogue part accessories). It is possible to reuse the service liquid. The pumps are equipped with a device by which the contaminated service liquid can continuously be drained during operation (dirt drain), if necessary. The direction of rotation is clockwise, when looking from the drive on the pump.

APPLICATION Handling and exhausting of dry and humid gases; entrained liquid can be handled during normal duty. The pumps are applied in all fields where a pressure of 33 to 900 mbar must be created by robust vacuum pumps. Fields of application are for example: chemistry and pharmacy for distilling and degassing, electric industry for impregnation and drying plastics industry for degassing etc.

GENERAL TECHNICAL DATA Pump type Speed Max. compression over pressure Max. admissible pressure difference Hydraulic test (over pressure) Moment of inertial of the rotating pump parts and of the water filling Sound pressure level at a suction pressure of 80 mbar Min. pulley diameter permissible in case of V-belt drive Max. gas temperature Service liquid max. admissible temperature max. viscosity max. density volume up to shaft level Max. flow resistance of the heat exchanger The combination of several limiting values is not admissible. dry saturated 50 Hz 60 Hz unit rpm bar bar bar kg m dB (A) mm C C C mm/s kg/m liter bar 355 160 80 60 90 1200 50 0,2 65
.

LEH 2200 735 880 1,5 1,5 3 8,7 80

LEH 3000

10,8

500

133.71331.51.01 E

VACUUM TECHNOLOGY LEH LE 5B 11/99

Material design
MATERIAL DESIGN Item 10.60, 10.70 10.90 13.70, 13.71 21.00 23.50 46.10 52.40 COMPONENTS Casing Central body Guide disk Shaft Vane wheel impeller Gland packing Shaft sleeve 1.4027.05 1.0553 Soft packing 1.4581 0B 0.6025 1.0038 0.6025 1.0503 1.4571 4B 1.4408 1.4571 1.4408

Sectional drawing LEH 2200, LEH 3000

Suction volume flow and power absorption LEH 2200

3000 m/h 2500


735 rpm 880 rpm

suction volume flow

2000

1500

1000

500 LEH 2200 0 10 40 60 80 100 200 400 mbar 1000

suction pressure

80 kW 70

power absorption

60 50
880 rpm

40 30 20 10 40 60 80 100 200 400 mbar 1000


735 rpm

LEH 2200

suction pressure

The operating data are applicable under the following conditions: pumping medium: service liquid: - dry air: - water vapour saturated air: water: 20C 20C 15C

Compression pressure 1013 mbar (atmospheric pressure) The suction volume flow is applied to the suction pressure Tolerance of the operating data 10% and of the power absorption 5% Max. fresh water need with lowest suction pressure

Suction volume flow and power absorption LEH 3000

4000 m/h
880 rpm

3500

suction volume flow

3000

735 rpm

2500

2000

1500 LEH 3000 1000 10 40 60 80 100 200 400 mbar 1000

suction pressure

120 kW 100

power absorption

80

60

880 rpm

40

735 rpm

LEH 3000 20 10 40 60 80 100 200 400 mbar 1000

suction pressure

The operating data are applicable under the following conditions: pumping medium: service liquid: - dry air: - water vapour saturated air: - water: 20C 20C 15C

Compression pressure 1013 mbar (atmospheric pressure) The suction volume flow is applied to the suction pressure Tolerance of the operating data 10% and of the power absorption 5% Max. fresh water need with lowest suction pressure

Dimension table LEH 2200, LEH 3000

N1 N2 uB uc weight app. kg 1025 1100 ue ul um um1 use

= = = = = = = = =

a LEH 2200 LEH 3000 630 750

m1 880 1000

m2 760 880

o3 1380 1500

q3 747 807

gas inlet DN 200 gas outlet DN 200 connection for service liquid G 1 connection for protection against cavitation G drain connection G connection for vent cock G connection for pressure gauge G connection for drain valve G connection for dirt drain G

flange connections to DIN 2501 PN 10 DN k D number x d2 150 240 285 8 x 22 200 295 340 8 x 23

Arrangement drawing LEH 2200, LEH 3000 with overhead liquid separator

N1 = N2 = uA = uF =

gas inlet DN 200 gas outlet DN 250 connection for liquid drain DN 80 connection for fresh liquid DN 40
electric motor 50 Hz size IP 55 kW EEx e ll T3 68 76 950 1830 e2 830 e3 1720

uc um ut

= connection for protection against cavitation G = connection for pressure gauge G = connection for thermometer G

weight l 2100 2250 l1 450 520 510 m 70 140 70 1251 o1 * 1200 w1 * 2638 2689 2809 app. kg 2320 2420 2500 2570

LEH 2200 LEH 3000

315 S 315 M 315 M 315 M

55 75 -

flange connections to DIN 2501 PN 10 DN k D number x d2 40 110 150 4 x 18 80 160 200 8 x 18 200 295 340 8 x 22 250 350 395 12 x 22

* dimensions dependent on the motor make

Arrangement drawing LEH 2200, LEH 3000 with upright liquid separator

N1 N2 uA uF uc

= = = = =

gas inlet DN 200 gas outlet DN 250 connection for liquid drain DN 100 connection for fresh liquid DN 40 connection for protection against cavitation G
electric motor 50 Hz size IP 55 kW EEx e ll T3 68 76 950 1830 e2 830 e3 1720

ue1 ufl um ut

= = = =

drain connection DN 25 connection for liquid level indicator G connection for pressure gauge G connection for thermometer G

weight l 2100 2250 l1 450 520 510 m 70 140 70 1251 o1 * 1200 w1 * 2584 2635 2755 app. kg 2325 2425 2500 2565

LEH 2200 LEH 3000

315 S 315 M 315 M 315 M

55 75 -

flange connections to DIN 2501 PN 10 DN 25 40 100 k 85 110 180 D 115 150 220 number x d2 4 x 14 4 x 18 8 x 18 * dimensions dependent on the motor make 200 295 340 8 x 22 250 350 395 12 x 22

Fresh water requirements


suction pressure [mbar] pump speed [rpm] LEH 2200 LEH 3000 735 880 735 880

in [m/h] dependent on suction pressure, speed, mode of operation and difference in temperature

33 KB difference in temperature [C] 10 5 2 2,3 3,1 2,7 3,8 4,1 5,4 4,8 6,3 7,8 9,4 8,6 10,4 18,6 FB

120 KB difference in temperature [C] 10 5 2 3,1 3,8 3,7 4,6 5,1 6,1 5,9 7,0 8,4 9,4 9,2 10,2 14,7 FB

200 KB difference in temperature [C] 10 5 2 3,2 3,9 3,9 4,8 5,2 6,1 6,0 7,0 8,1 9,0 8,9 9,8 13,2 FB

400 KB difference in temperature [C] 10 5 2 3,2 3,8 3,8 4,6 4,9 5,6 5,7 6,5 7,3 7,9 7,9 8,5 10,8 FB

FB = fresh liquid service KB = combined liquid service with service water 10 C, 5 C, 2 C warmer than the fresh water.

Data regarding the pump size - order notes


series + size A B hydraulics + bearings shaft sealing 0B 041 double gland packing 4B material design main parts of GG without non-ferrous metal main parts of Cr Ni Mo cast steel 0B, 4B casing seal

hydraulic A two grease lubricated antifriction bearings AB

liquid seal

LEH

2200 3000

041

Design - Motor selection table


designation pump with free shaft end pump with coupling, pre-drilled at motor side as above, but with motor, for example 75 kW three-phase motor (50 Hz, 400 V) at 735 rpm Example for ordering: The construction size LEH 3000 AB 041 0B 0 with 75 kW three-phase ac motor (50 Hz, 400 V) 735 rpm has the complete order number: If motors with other voltage or frequency are required a special information should be given. On delivery the point () in the fourth place of the type code is replaced by a letter in the factory. LEH 3000 AB 041 0B 0 FD 01 04 e.g. FD kW 55 75 electric motor 50 Hz motor enclosure IP 55 size 315 S 315 M designation ED FD kW 68 76 motor enclosure EEx e ll T3 size 315 MB 315 MC designation FM GM

Accessories
Recommended accessories Overhead liquid separator material design service liquid line material design cavitation protection line material design Upright liquid separator material design service liquid line material design cavitation protection line material design SIHI-gas ejector on request Non-return valve on request Motor in case of standard design IP 55 size power weight size power weight type / weight SIHI part No. type / weight SIHI part No. 315 S 55 kW 780 kg 315 M 68 kW 875 kg A 225 / 27 kg 43 031 212 43 029 025 ADS 245 / 32 kg 43 040 601 43 029 321 35 004 808 35 004 809 35 005 915 262 kg 35 006 060 269 kg 35 006 060 269 kg 315 M 75 kW 875 kg 315 M 76 kW 940 kg 072 / St 37-0 172 / 1.4571 SIHI part No. 20 042 995 20 042 996 20 042 993 20 042 994 072 / St 37-0 172 / 1.4571 SIHI part No. 35 006 067 35 006 068 35 006 071 35 006 072 130 / galvanized 172 / 1.4571 072 / St 37-0 172 / 1.4571 SIHI part No. type weight SIHI part No. 20 037 202 20 037 203 XBp 5016 153 kg 35 006 074 35 006 075 20 037 204 20 037 205 072 / St 37-0 172 / 1.4571 SIHI part No. 35 006 069 35 006 070 35 006 062 35 006 063 130 / galvanized 172 / 1.4571 type weight SIHI part No. LEH 2200 XBa 10045 150 kg 35 009 513 35 009 514 LEH 3000 XBa 10044 155 kg 35 009 516 35 009 517

EEx e ll T3

Coupling for motor IP 55 pump side motor side for motor EEx e II T3 pump side motor side contact safety device material design base frame for motor IP 55 for motor EEx e ll T3 076 / steel 345 / 2.0321 081 / USt 37-1 081 / USt 37-1

SIHI part No.

SIHI part No. weight SIHI part No. weight

Any changes in the interest of the technical development are reserved.

Sterling SIHI GmbH Lindenstrae 170 , D-25524 Itzehoe, Germany , Telephone +49 (0) 48 21 / 7 71-01 , Fax +49 (0) 48 21 / 7 71-274