You are on page 1of 18

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

1.General Everyindividualvendorstallshallcomplywithallapplicablebuildingcodes,including InternationalBuildingCode(IBC)2009,CityofPittsburghamendments,AlleghenyCounty HealthDepartmentcommercialfoodservicecodesandregulations,Americanwith DisabilitiesActGuidelines(ADAAG)andAmericanNationalStandardsInstitute(ANSI). Stalldesignandconstructionshallbehighquality,safeandofsturdyconstruction.Stalls shallinnowayimpedethesafe,secureandreasonableoperationofotherstallsorofthe marketingeneral. Vendorsareencouragedtoconstructtheirstallsoffsiteforassemblyanderectioninthe MarketHallspace. Stallsconstructedonsitemustbeconstructedbyalicensedcontractorapprovedbythe PittsburghPublicMarketandwillbesubjecttoPrevailingWageGuidelines. Manystallsaresubjecttobuildingfeaturesincludingcolumns,doorhardware,andpower locations.Actualdimensionsofthestallareamanyvaryslightlyfromthenominalsizesbased onfieldconditions.ItistheVendorsresponsibilitytoinspecttheirdesignatedstalllocation andverifythedimensionsandthespecificconditionsoftheirstallsitepriorfinalizingtheir designorconstructingtheirstalltocoordinatethesecolumnlocations,powerlocations, dimensions,etc. 2.DemarcatedVendorSpace Stallmustbeconstructedandmaintainedentirelywithinthevendorsdemarcatedspace, definedasthewidth,lengthandheightindicatedintheDesignGuidelinedrawings (AppendixIII).Nooverhangs,counters,counterextensions,bulkheads,displays,fixtures, seating,orotheraccessorieswillbepermittedbeyondtheindividuallydemisedspacenor protrudeintothedesignatedcirculationandwalkwayareas.Signsandbulkheadsare permittedwithinthedemarcatedspaceinaccordancewithsignagedesignguidelines. Demarcatedstallareashallhavedefinedboundariesthatallowsecurityforitselfand neighboringstalls..Vendorsshallarrangetheirspacesforsafeoperationandmovementfor publicandemployees. AnyspacesaccessibletothepublicwithinthedemisedspaceshallbeADAandANSI accessibletoboththepublicandvendoremployees,asrequired.Refertotheattached drawingsforclearances Aislesmustmeetclearwidthrequirementsforaccessibility,andbeaminimumof32wide. Aislesmustbemaintainedfreeandclearoffixedorlooseobstructionsatalltimes.See DrawingsandDiagramsfor: Overallmarketfloorplan,stalllayout,buildingsectionandservicesplans. Overallvolumeboundarydimensionsofstall,includinglength,widthandheight ADAclearances,turningcircles,doorclearances,countertops,heights,reachranges, etc. Productdisplayguidelines(ADAheightsandreachranges) Servicesconnections 1of8

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

3.Structure&Layout Stallsmaybeconstructedwithinthedefinedvolume.Stallsmayhavestructuraland decorativecolumnsorpostsateachcornerinafourposterarrangement.Solidwallsor infillpanelsarepermittedto8feetinheighthoweverVendorsareencouragedtouseopen typematerialssuchasmetalgridtomaintainvisibilityandairflow.Solidsidewallstaller than6feetinheightmustnotrunthefulllengthofthesideperpendiculartothemain publicaisle,butrathermuststop2feetbackfromthemainaisletoallowforvisibility betweenstallsandthroughoutthemarketingeneral.Thebacksofsolidwallsfacingother stallsmustbefinishedinkeepingwiththefronts,ofsimilarmaterialandquality.Designand constructionofstallshallallowforcoordinationwithandvisibility/audibilityofallbuilding systems,includinggenerallighting,sprinklers,firealarms,etc. Stallsshallbesturdyandsecurebutmaynotbepermanentlyfastenedtothefloor.Power actuatedfasteners,drilledholesorwedgeanchorsarenotpermitted. Floorsshallbelevelasmuchaspossible.Anyflooraccessibletothepublicmayhavea maximumthreshold.Floorsareasnotaccessibletopublicmayberaisedprovidedthe raisedfloorareaisstructurallystableandwellsupported.Allspacescreatedunderaraised floormustbecompletelyenclosedtopreventaccumulationoftrashanddebris.Stepsor rampsshallcomplywithIBC,ADAandANSI. 4.Design&Materials Thestallstructureshallbeasafe,open,attractiveandwelcomingspacefromwhichavendor cansellhisorhergoodstothepublic.Stallsareencouragedtobecreativeandarchitecturally interesting,varyingfrommerchanttomerchant,usingshapes,materials,textures,color, sculpturalandarchitecturalelementstoreflecttheindividualstyleandessenceofgoodsbeing offered.Thedesignandaestheticofthestallsshallbepleasingandenhancetheoverall marketambianceandexperience.Uniquecharacterandinterestencouraged. Vendorstallsmustbewelldesignedandconstructedofpermanent,highquality,structurally sound,finishgradematerials,suchaswood,metal,polycarbonate/fiberglasspanels,glass,or drywall.Stallsshallnotbetemporaryinnature;tents,lawncanopies,thinmetalpolesor framesarenotpermitted.Unfinishedorrawroughconstructionmaterialsarenot permitted,suchasroughwoodstuds,OSB,rawdrywall,roughorstampedplywood, cardboard,chipboard,foamcore,etc. Materialstypicallyusedforroughconstructionsuchasplywood,fiberboard,agriboard, OSB,etc.shallbepermittedonlyiftheyarefinishgrade,clean,withnoroughedges,no visiblestampsormarkingsandsealedandcreativelytreatedlikefinishgradematerials. Allglassandglazingpanelsshallbetemperedorapprovedlaminatedsafetyglass.Plateglass mirrorsarepermittedwhenattachedtoasolidsubstrate. Useofantique,salvagedorrecycledproductsisencouraged,providedsuchmaterialsare clean,freeofsignificantdamage,smoothwithnoroughedgesandfinishedortreated (stained,painted,sealed)appropriately. 2of8

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

Highlycombustible,flammable,hazardousortoxicmaterialsarenotacceptableinthe constructionofstalls,norshalltheybepermittedtobestoredorsoldonpremises. Suggestedandencouragedmaterialsinclude: Finishedwood o Woodshallbestained,sealedorvarnished,orpainted. o Finishhardwoods;oak,cherry,etc. o Finishedsoftwoods;pine,firetc.arepermittedbutmustbesealedorfinished Metal o stainlesssteel o galvanizedsteel o paintedaluminum o brass o chrome o wroughtiron 5.Dining&WorkSurfacesandCountertops Countertopsshallbefinished,durableandeasilycleanable.Suitablecountertopmaterials include: Wood ButcherBlock Metal(stainlesssteel) Glass PolymertypesolidsurfacematerialssuchasCorian Fiberglassreinforcedpanel(FRP) Counterseatingispermittedwithindemarcatedspaceoutline.Countertopseating,if provided,shallbefixedorallowadequatespaceformovementandpassagewheninuse.The requiredclearspaceispermittedtooccurinthepublicaisles.Diningandworksurfacesshall beADAandANSIaccessible,withaheighttothetopof28minimumand34maximum abovefloor.Atleast5%,butnotlessthanone,oftheseatingandstandingspaces,,shallbe accessible. Wherediningsurfacesfortheconsumptionoffoodordrinkareprovided,atleast5%,butnot lessthanone,oftheseatingandstandingspacesatthediningsurfacesshallbeaccessible.A portionofthecountersurface36minimuminlengthand36maximuminheightabovethe floorshallbeprovided. Thecheckoutcountersurfaceshallbe38maximuminheightabovethefloor. 6.Flooring Existingfloorwillbepowerwashed,butnotrepainted,priortoleasing.Cutting,grinding, paintingorstaining,oranyotheralterationsoftheexistingfloor,arenotpermittedby vendors.Thestallstructureshallnotrequiremechanicalattachmenttothefloor.Vendor providedflooringshallbedurable,commercialgrade,slipresistant,cleanableflooring products.Anyflooringshallbesecurelyfastenedtotheconcretesubfloorandnotpullupor 3of8

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

presenttrippinghazards.Anyfinishfloormaterialsmustberemovablewithoutadhesive residueordamagetotheexistingfloor.Flooringshallbeattractiveandaestheticallypleasing, intendedforfinishuseandpublicview.Flooringshallbewellmaintained,cleanable,and cleanatalltimes. Floortransitionsshallcomplywithaccessibilitycodes,withnotransitionexceeding3/4in height.Provideathresholdortransitionstripwhereflooringmaterialschange. 7.Ceilings Stallceilings,ifprovided,mustbestructurallysupportedandopentogenerallighting,power, andsprinklers.Acceptableceilingtypesincludemesh(metal,wood,screenmaterial),trellis typearrangements,orloosedecorativeceiling,withminimum50%openarea.Drapedfabric isnotpermittedunlessmaterialisfireretardant. Nothingistobestoredontopofceilings. 8.Signage Signageshallconformtosignageguidelinespublishedseparately.Anyvisiblemarkings, logosortextpermitteddirectlyonstallcomponents(columns,walls,etc)arepermittedif compliantwithsignageguidelines.Signageshallbeclearlyvisible,legible,cleanandwell maintained. Artisticandaestheticallypleasingelectronicandneonsignsarepermittedwithinthestall only.Suchsignsmustbelessthan5squarefeetinarea.Allelectricsignsmustbesubmitted forapproval.Electricsignsmustbeplugintypeandanypowerdrawmustbewithinthe40 amptotalpowerlimit.Electricsignsmustbesecurelyattachedtothestallorotherfixed component.Freestanding,movable,ortemporaryelectricsignsarenotpermitted.Wiring shallbeconcealedasmuchaspossible,andtiedorboundabovethefloorsoasnottohangor presentacatchinghazard. 9.Display,Appliances&Furnishings Tables,shelving,cabinets,displayaccessories,appliancesandfurnishingsshallbesturdy,self supporting,cleanandwellmaintained.Theyshallbecapableofsupportingthesuper imposedload.Theyshallbesuitableforpublicviewandcommercialuse.Utilitytype shelvingortableswithroughedges,exposedfastenersorbrackets,orirregularfinishesshall notbeusedunlessacceptablycoveredwithsuitablematerial,suchastableskirtsortable cloths.Avarietyofshelvingtypesareacceptableincluding;wood,metalandwireshelving, pressedboardshelving,wickerormetalbaskets,metalbuckets,creativelyfinishedshipping palettes,winebarrels,attractivewoodcratesandboxes.Displaysfashionedfromroughor dilapidateditems,suchascardboardboxesarenotacceptable.Itemssuchasplastic5gallon bucketsmaybepermittedifnew,andusedinacreativeandestheticallypleasingmanner. Vendorsmay,andareencouragedtodisplayappropriategoods(suchassalami,dried peppers,craftitems,clothing,etc.)byhangingdirectlyfromstallstructure.Suchitemsmust notimpedewithrequiredheightclearances. 4of8

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

Temperaturecontrolledandotherpowereddisplayitems,suchasbeveragecoolers,reach inrefrigerators/freezersorcasesarepermitted.ProvideEnergyStarratedappliancestothe fullestextentpossible.Suchitemsshallbeusedaccordingtomanufacturerswritten instructions.Powerandmotorareasshallbescreenedfromview,andkeptfreeofdebrisand obstructions,asmuchaspossible.Backsofcoolersmustnotbevisiblefrompublicwalkways andaisles. Furnishings,suchastablesandchairs,maybeprovidedwithinthedemarcatedstall boundary. Liveplantmaterial,fordecorationorsale,maybedisplayedwithinthedemarcatedstall boundary. Fabric,curtains,awningsandcanopiesmustnotimpedetrafficandbeofflameretardant material. Alldisplays,appliancesandfurnishingsshallbemaintainedinasafe,clean,orderlyand attractivemanner. 10.Waste Trash,recyclingandfoodwaste/compoststorageandcollectionareasshallbeincorporated intostalldesignandconstructionsoastobekeptoutofviewofthepublictothefullestextent possible.Trashincludesallwasteproductsincludingfood,containers,paperwaste,shipping palettes,cardboardboxes,plasticwrapping,bags,etc.Generaltrashandrecycling receptacleswillbeprovidedthroughoutthemarketforpublicuse. Foodwasteappropriateforcomposting(noanimalproductsorprocessedfoods)mayentera generalcomposter,ifavailable. 11.Services Availablepoweris110Vsinglephase.Vendorsmustsubmitalistofanticipatedpower requirementitemsandtotalexpectedloadinampsforreviewandapproval. Standardpowertoeachvendorstallshallconsistof110Vconvenienceoutletswithinthe demarcatedarea.Convenienceoutletswithatotalofeight8plugspaceswillbeprovidedto eachstall.Onecentralquad20ampcircuitoutlet(4plugspaces)willbeprovidedtoeach stall.Accessto1/2oftwoadjacentquad20ampcircuitoutlets(2plugspacesoneitherside ofstall)willbeprovidedtoeachstall.Thetotalpowerlimitforastandardstallis40amps. Vendorswithmultiplestallsshallhaveaccesstotheadditionaloutletsintheadditionalstalls andanadditional40ampspervendorstall. Vendorsmayoverlaptheiruseofpoweroutletstoincreaseordecreasethenumberofoutlets withtheneighboringstallvendorsasagreedbetweentheindividualvendorsand independentoftheMarketCouncil.Absentsuchagreement,allvendorsshalllimittheir poweraccesstotheplugsandoutletswithintheirdemarcatedspace. 5of8

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

Generallightingisprovidedtothespaceviaoverheadlightfixtures.Lightingiscontrolled centrallyduringmarkethours.Vendorsmayaddtheirowndecorativelighting,suchas accentlights,displaylamps,specialtylights,stringsofChristmaslights,etc.Vendor providedlightingmustbeplugintype.Additionalhardwiredlightingfixturesarenot permitted. Ageneralbuildingheatingandventilatingsystemwillbesettoachieve45to55degreesin winter.Generalairconditioningisnotprovided.Itisanticipatedthatduringperiodsof warmweather,exteriordoorswillremainopentoprovideventilation.Portableheaters(gas andelectric)arenotpermitted. No ceilingorpedestal fans are p r ermitted . within individual vendor booths. Nootherindividualvendorserviceconnections,suchaswater,gas,telephoneordatalines willbeprovided.ThemarketwillinstallaDSLlineconnectedtoawirelessrouterthatwill allowwirelessinternetaccessforvendorstoresearch,orderandtakecreditcardpayments, pendingtheirindividualbusinessmodelandequipment.Acentralthreebowlsinkanda handsinkwillbeprovidedinthegeneralmarketarea. 12.Smoking&Fire Tobaccosmokingisnotpermittedwithinthemarket,orwithinindividualstalls. Openflames,includingfirepits,torches,cookingdemonstrations,etc.arenotpermitted. 13.Security Individualstallsecurityistheresponsibilityofandistobeprovidedbythevendor.Methods ofsecuringthestallscouldincludefoldingdoors,bifoldpanes,removablepanels,lockable coverings,screensortarps,etc.Securityitemsmustbestoredwithinthedemarcatedstall spaceandbeonlyminimallyvisibleduringmarkethoursunlessotherapprovedprovisions aremade. Themarketwillinstallmotiondetectorsthroughoutthemarketspaceandpayfor24/7remote securitymonitoringofthesemotiondetectors. 14.Submittals Vendorsmustsubmitdesignandconstructiondrawingsoftheirproposedstalldesignstothe MarketArchitectandMarketCouncilforapproval.ApprovalswillberelayedtoURAand BuildingManagerfortheirapproval.Drawingsmustbelegibleandshowalldimensions andmaterials.Nostallshallbeconstructedpriortoapproval.


6of8

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

AppendixI(Attached)
Examplephotosareofmarketstallsinothermarketsandsomesubmittedbyourmarket vendors.Pleasenote,thesearejustexamplesanddonotprovidealltherequired information.Theyareincludedjusttogiveideas.

AppendixII
A1Materials Useofenvironmentallyfriendlyandnontoxicmaterialsandpracticesarestrongly encouraged.Particularlyforstructuresconstructedonsitethefollowingguidelinesare suggested: Tothefullestextendpossible,recyclewasteduringconstructionanddisposeofall materialappropriatelyandinthemostenvironmentallyfriendlywaypossible. Uselocalandregionalbuildingmaterials;productsthathavebeenextracted,harvested orrecovered,andmanufacturedwithin500milesofthemarketlocation,fora minimumof20%(basedoncost)oftotalmaterialsvalue. Usematerialswithrecycledcontent. Userapidlyrenewablematerials(madefromplantsthataretypicallyharvestedwithin a10yearorshortercycle) UsewoodbasedmaterialsandproductsthatarecertifiedinaccordancewiththeForest StewardshipCouncil(FSC)principlesandcriteria. Compositewoodandagrifiberproductsshallcontainnoaddedureaformaldehyde resins.Theseincludeparticleboard,mediumdensityfiberboard(MDF)plywood, wheatboard,strawboard,etc. Foronsiteconstruction,useadhesivesandsealantsthatcomplywithSouthCoastAir QualityManagementDistrict(SCAQMD)Rule#1168.VolatileOrganicCompound (VOC)limitslistedbelowareexamplesofproductscovered,andisnotanexhaustive list: ArchitecturalApplications VOCLimit(g/Llesswater) o Indoorcarpetadhesives 50 o Woodandrubberflooringadhesives 100 o Ceramictileadhesives 65 o VCTandasphaltadhesives 50 o Drywallandpaneladhesives 50 o Multipurposeconstructionadhesives 70 o Architecturalsealants 250 o Generalpurposemistsprayadhesives 65%VOCsbyweight 7of8

PittsburghPublicMarket

VendorStallDesignGuidelines06/15/10

Foronsiteconstruction,usepaintsandcoatingsthatcomplywiththefollowing: o Wallsandceilings: ComplywithGreenSealStandardsGS11, Paints,1993 50g/LVOCorless. o Anticorrosive/antirustcoatings ComplywithGreenSealStandardsGC 03,Anti CorrosivePaints,1997 250g/LVOCorless o Clearwoodfinishes,stains,etc. SCAQMDRule1113

A2Accessibility PerIBC1108.2.9:Floorareaallottedforseatingandtablesshallbeaccessibleandwhere diningsurfacesfortheconsumptionoffoodordrinkareprovided,atleast5%,butnotlessthan one,oftheseatingandstandingspacesatthediningsurfacesshallbeaccessibleandbe distributedthroughoutthefacility. PerIBC1109.10:Whereseatingorstandingspaceatfixedorbuiltintables,countersorwork surfacesisprovidedinaccessiblespaces,atleast5%oftheseatingandstandingspaces,butnot lessthanone,shallbeaccessible PerIBC1109.11.3,wherecountersareprovidedforsalesordistributionofgoodsorservices,at leastoneofeachtypeprovidedshallbeaccessiblePerANSIChapter9,salesandservice countersshallhaveaccessibleparallelorforwardapproaches.Theaccessibleportionofthe countertopshallextendthesamedepthasthesalesandservicecountertop. 904.3.1ParallelApproach:Aportionofthecountersurface36minimuminlengthand 36maximuminheightabovethefloorshallbeprovided.Wherethecountersurfaceis lessthan36inlength,theentirecountersurfacesshallbe36maximuminheight abovethefloor.Aclearfloorspaceof30x48,positionedforaparallelapproach adjacenttotheaccessiblecounter,shallbeprovided. 904.3.2ForwardApproach:Aportionofthecountersurface30minimuminlengthand 36maximuminheightabovethefloorshallbeprovided.Aclearfloorspaceof 30x48,positionedforaforwardapproachtotheaccessiblecounter,shallbeprovided. ANSIcompliantkneeandtoeclearancesshallbeprovidedundertheaccessiblecounter. Therequiredclearspaceispermittedtooccurinthepublicaisles. PerIBC904.4.2:Thecheckoutcountersurfaceshallbe38maximuminheightabovethefloor. Thetopofthecounteredgeprotectionshallbe2maximumabovethetopofthecounter surfaceontheaislesideofthecheckoutcounter.

AppendixIII(Attached)
DesignGuidelinedrawings.

8of8

You might also like