You are on page 1of 38

CSE3032 STRUCTURAL & TALL BUILDING

CHAPTER 2 Design of R.C. Slabs



Learning Objectives Acquire the knowledge of the requirements of the new HK Code in designing RC slabs. Appreciate the structural actions of different types of slab elements. Apply HK Code to design 2-way slab and rib slab (fcu 40 N/mm2, fy = 460 N/mm2 and fyv = 250 N/mm2)

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

2. R.C. Slabs 2.1 Types of Slab Slabs are plate elements forming floors and roofs in buildings which normally carry uniformly distributed loads. Slabs may be simply supported or continuous over supports. Slabs can be classified as: One-way spanning slabs supported by beams or walls. The slabs can be simply supported or continuous as shown in Figure 2.1(a) & (b). In drawing, one-way spanning slab is shown as . Figure 2.2 shows a typical one-way spanning slab. Two-way spanning slab supported by beams or walls. Two-way spanning slabs can be simply supported or continuous as shown in Figure 2.3. In drawing, two-way spanning slab is shown as Ribbed is shown in Figure 2.4. Waffle slabs are shown in Figure 2.5, Photo 2.1, 2.2 & 2.3. Flat slabs carried on columns and edge beams or walls with no interior beams (see Figure 2.6, Figure 2.7, Photo 2.4 and 2.5).
Moment Steel Distribution Steel d h Span L
(a) Moment Steel

Distribution Steel

Span L
(b)

Beam

Figure 2.1 (a) Simply Supported Slab

(b) Continuous One-Way Slab

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

Figure 2.2 One-way Spanning Slab6

Figure 2.3 Two-Way Spanning Slab6

Figure 2.4 Ribbed Slab6

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

Figure 2.5 Waffle Slab Designed as a Flat Slab6

Figure 2.6 Flat Slab without Drop

Figure 2.7 Flat Slab with Drop and Column Head6

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

Photo 2.1 Waffle Slab

Photo 2.2 Waffle Slab

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

Photo 2.3 Waffle Slab

Photo 2.4 Flat Slab

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

Photo 2.5 Flat Slab

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

2.2 Design of Two-way Spanning Solid Slab When floor slabs are supported on four sides two-way spanning action occurs as shown in Figure 2.8. In square slabs, the action is equal in each direction. In narrow slabs where the length is greater than twice the breath the action is effectively one way. However the end beams always carry some slab load.

Edge Beam

ly

lx

Strips spanning between supports

(l y > 2 lx ) Strip spans across short span (b) One-way action

(a) Two-way action

Figure 2.8 Two-way and One-way Action

Two-way slabs may be classified according to the edge conditions. They can be defined as follows: Simply supported one panel slabs where the corners can lift away from the supports. A one panel slab held down on four sides by integral edge beams (the stiffness of the edge beam affects the slab design) Slabs with all edges continuous over supports A slab with one, two or three edges continuous over supports - the discontinuous edge(s) may be simply supported or held down by integral edge beams (see Figure 2.9)

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

D D C

D C

D D

C D C

C C

D C

C D D C

C
D D

C - Continuous Edge D - Discontinuous Edge

Figure 2.9 Edge Conditions

2.2.1 Two-way Spanning Simply Supported Slabs The design of simply supported slabs may be made in accordance with HK Code, Cl.6.1.3.3. This cl. gives the following equations for max. moment msx and msy at mid-span on strips of unit width for spans lx and ly respectively, where lx is the length of shorter span, ly is the length of the longer span, n = 1.4gk + 1.6qk per unit area and sx, sy are the moment coeff. from Table 6.55 of the code. msx = sxn lx2, msy = syn lx2

Table 6.5 Bending moment coefficients for slabs spanning in two directions at right angles, simply supported on four sides ly / lx 1.0 1.1 1.2 1.3 1.4 1.5 1.75 2.0 sx sy 0.062 0.062 0.074 0.061 0.084 0.059 0.093 0.055 0.099 0.051 0.104 0.046 0.113 0.037 0.118 0.029

Chapter 2
HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

The centre strips and location of max. moments are shown in Figure 2.10
ly
1m 1m msy Load on beam B

B A

lx
msx 1m (a)
Load on beam A

1m
(b)

Load causing shear

Figure 2.10 (a) Centre Strips

(b) Loads on Beams and Slab Shears

2.2.1.1

Design Requirements for Two-way Slabs

Bending Reinforcement (For fcu 45 N/mm2, Normally K 0.156)

i)
ii )

K=

M 0.156 bd 2 f cu
(z 0.95d and z 0.775d)

K z = d 0.5 + 0.25 0.9 M iii ) As = 0.87 f y z

The min. area of main reinf. is:For rectangular sections and solid slabs:100 As Mild steel, fy = 250 N/mm2, = 0.24 Ac 100 As High yield steel, fy = 460 N/mm2, = 0.13 Ac

Chapter 2
HD in Civil Engineering

10

CSE3032 STRUCTURAL & TALL BUILDING

Distribution Steel The distribution steel runs at right angles to the main moment steel and serves the purpose of tying the slab together. The area of distribution steel is the same as the min. area for main reinforcement (i.e. 0.13%) and the distribution reinforcement of not less than 20% of the principal reinforcement should be provided.
Shear Reinforcement (For fcu = 40 N/mm2) Under normal loads shear stresses are not critical and shear reinforcement is normally not required. Shear reinforcement is provided in heavily loaded thick slabs but should not be used in slabs less than 200 mm thick.

In design, the average shear stress v is given by v = V/bd The design procedures for slab are essentially the same as that for beams. However, in the design of slab in shear, the following points should be noted. i) v should not exceed 0.8 f cu or 7 N/mm2 whichever is less. ii) If v < vc, then no shear reinforcement is required. iii) If vc < v (vc + 0.4), then provide min. links as:Asv 0.4b sv 0.87 f yv
iv) if v > (vc + 0.4), provide shear links as Asv (v vc )b sv 0.87 f yv

Chapter 2
HD in Civil Engineering

11

CSE3032 STRUCTURAL & TALL BUILDING

Deflection In slab design, deflections are usually controlled by limiting the span/effective depth ratio.

i)

Basic span/effective depth ratio (Table 7.3):Cantilever slab 7 Simply supported slabs 20 Continuous slabs 26 End Span 23
For deflection control, it is necessary to check the span/effective depth ratio of the shorter span.

i)

The basic span/effective depth ratio is multiplied by a modification factor for tension reinforcement (Table 7.4). Only the tension steel at the centre of span is taken into account. Determination of the allowable span/effective depth ratio. Allowable l/d ratio = Basic l/d ratio * M.F for tension reinforcement. Determination of the actual span/effective depth ratio. Actual l/d ratio = (Actual span) / (Effective depth) If allowable l/d ratio actual l/d ratio, Deflection O.K. If allowable l/d ratio < actual l/d ratio, Deflection NOT O.K. (Redesign the slab)

ii)

iii)

iv) v)

Crack Control To control cracking in slabs, max. values for clear spacing between bars are set out in HK Code, Cl.9.3.1.1 (b). The maximum spacing of bars should comply with the following requirements: For the principal reinforcement, 3h 400 mm; and For the secondary reinforcement, 3.5h 450 mm.

In areas with concentrated loads or areas of maximum moment those provisions become respectively: For the principal reinforcement, 2h 250 mm; and For the secondary reinforcement, 3h 400 mm.

Chapter 2
HD in Civil Engineering

12

CSE3032 STRUCTURAL & TALL BUILDING

In addition, unless crack widths are checked by direct calculation, the following rules will ensure adequate control of cracking for slabs subjected to normal internal and external environments: No further check is required on bar spacing if either: h 250 mm (grade 250 steel) h 200 mm (grade 460 steel) or the percentage of required tension reinforcement (100As / bd) is less than 0.3%. Where none of these three conditions apply, the bar spacings should be limited to the values calculated in cl. 9.2.1.4 which will NOT be covered here.

Chapter 2
HD in Civil Engineering

13

CSE3032 STRUCTURAL & TALL BUILDING

Example 2.1 Two-Way Spanning Simply Supported Slab

Figure 2.11 shows a simply supported slab 220 mm thick and spanning in two directions. The effective span in each direction of a two-way spanning slab is 4.5 m and 6.3 m. The slab supports a live load of 10 kN/m2. Design the bending and shear reinforcement for the slab. Check the adequacy of the slab section against deflection by span-effective depth ratio approach. The characteristic material strengths are fcu = 35 N/mm2 and fy = 460 N/mm2. Nominal cover = 25 mm.

(220) 6.3m Figure 2.11


Solution

ly / lx = 6.3/4.5 = 1.4

From design table 6.5, sx = 0.099 and sy = 0.051 Self-weight of slab = 0.22*24 = 5.28 kN/m2 Imposed load = 10 kN/m2 Design load n = 1.4*5.28 + 1.6*10 = 23.4 kN/m2

4.5m

Chapter 2
HD in Civil Engineering

14

CSE3032 STRUCTURAL & TALL BUILDING

Bending (Short Span) msx = sx*n*lx2 = 0.099*23.4*4.52 = 46.9 kNm d = 220 -25-12/2 = 189 mm

msx 46.9 *10 6 = = 0.038 < 0.156 bd 2 f cu 103 *189 2 * 35 From design table 1, z = 0.95d = 0.95*189 = 179 mm.

M 46.9 *10 6 = = 655mm 2 As = 0.87 f y z 0.87 * 460 *179 Provide T12 - 150 c/c (As = 754 mm2)

100 As 100 * 754 = 3 = 0.34 > 0.13 bh 10 * 220 < 4.0 O.K.
Bending (Long Span) msy = sy*n*lx2 = 0.051*23.4*4.52 = 24.2 kNm

d = 220 -25-12 - 10/2 = 178 mm 24.2 *10 6 = = 0.022 < 0.156 bd 2 f cu 103 *1782 * 35 From design table 1, z = 0.95d = 0.95*178 = 169 mm. msy
As = M 24.2 *10 6 = = 358mm 2 0.87 f y z 0.87 * 460 *169

Provide T10 - 200 c/c (As = 393 mm2)

100 As 100 * 393 = 3 = 0.18 > 0.13 bh 10 * 220 < 4.0 O.K.

Chapter 2
HD in Civil Engineering

15

CSE3032 STRUCTURAL & TALL BUILDING

Deflection (Check Short Span Only)

Basic l/d ratio = 20 (table 7.3)


M sx 46.9 *10 6 = = 1.31 bd 2 103 *189 2

fs =

As req 2 2 655 = * 460 * = 266 N/mm 2 fy As prov 3 3 754 modification factor = 1.35

From design table 7.4,

Allowable l/d ratio = 20*1.35 = 27.0 Actual l/d ratio = 4500 / 189 = 23.8 < allowable ratio = 27.0 O.K.

Shear (Most Critical in Long Span Direction) Max. shear force per 1 m width slab V= 23.4*4.5/2 = 52.7 kN

Shear stress v = 52.7*103 / (103*178) = 0.30 N/mm2


100 As 100 * 393 = = 0.22 (Long Span) bd 1000 *178 35 3 From design table 6.3, vc = 0.47 x N/mm2 > 0.30 N/mm2 25 No shear reinforcement required.
1

Chapter 2
HD in Civil Engineering

16

CSE3032 STRUCTURAL & TALL BUILDING

2.2.2

Restrained Two-way Spanning Solid Slabs2

2.2.2.1 Design and Arrangement of Reinforcement The design method for restrained slabs is given in HK Code Cl.6.1.3.3(c). In these slabs the corners are prevented from lifting and provision is made for torsion. The maximum moments at mid-span on strips of unit width for spans lx and ly are given by:

msx = sx n l x

2 2

msy = sy n l x

The moment coefficients sx and sy in the equations above are given in HK Code Table 6.65. The clause states that these equations may be used for continuous slabs when the following provisions are satisfied. The characteristic dead and imposed loads are approximately the same on adjacent panels as on the panel being considered. The spans of adjacent panels in the direction perpendicular to the line of the common support are approximately the same as that of the panel considered in that direction.

ly ly 8 Edge strip
Edge strip Edge strip

ly 8
lx lx

8 8
lx
Chapter 2

middle strip

Edge strip
Figure 2.12 Division of Middle and Edge Strips

17

HD in Civil Engineering

CSE3032 STRUCTURAL & TALL BUILDING

The design rules for restrained TWO-WAY slabs are as follows: The slabs are divided in each direction into middle and edge strips as shown in Figure 2.12. The maximum moments defined above applied to the middle strip. The bars are spaced uniformly across the middle strip. At the discontinuous edge, it is a usual practice to have the top steel equals to one-half the area of the bottom steel at mid-span to be provided to control cracking. The minimum tension reinforcement is to be provided in the edge strip together with the torsion reinforcement specified below. Torsion reinforcement is to be provided at corners where the slab is simply supported on both edges meeting at the corners. Corner X and Y shown in Figure 2.13 require torsion reinforcement. This consists of a top and bottom mesh with bars parallel to the sides of the slab and extending from the edges a distance of ONE-FIFTH of the shorter span. The area of bars in each of the four layers should be, at X, THREE-QUARTERS of the area of bars required for the maximum mid-span moment and, at Y, ONE-HALF of the area of the bars required at corner X. Note that no torsion reinforcement is required at the internal corners Z.
X

Figure 2.13 Torsional Reinforcement for Two-Way Slabs

Chapter 2
HD in Civil Engineering

18

CSE3032 STRUCTURAL & TALL BUILDING

Table 6.6 sx and sy from HK Code5

Chapter 2
HD in Civil Engineering

19

CSE3032 STRUCTURAL & TALL BUILDING

2.2.2.2 Adjacent Panels with Markedly Different Support Moments.

The moment coefficients in Table 6.65 of the code apply to slabs with similar spans and loads giving similar support moments. If the support moments for adjacent panels differ significantly, adjustment by means of moment distribution is required. The detailed procedures are given in cl. 6.1.3.3 (e) of the code. An example can be found in ref. 3. Detailed description will not be given here.
2.2.2.3 Loads on Supporting Beams of Two-way Slabs

Shear force coefficients vx and vy for various support cases for continuous slabs are given in Table 6.75 of the code. The design loads on supporting beams per unit width are given by:

Vsx = vx n l x Vsy = vy n l x
The load distribution on a beam supporting a two-way slab is shown in Figure 2.14.

0.75l Vs kN/m

l
Figure 2.14 Distribution of Load on a Beam Supporting a Two-Way Spanning Slab

2.2.2.4 Shear Resistance, Deflection & Cracking Similar to those of simply supported two-way spanning slabs.

Chapter 2
HD in Civil Engineering

20

CSE3032 STRUCTURAL & TALL BUILDING

Table 6.7 vx and vy from HK Code5

Chapter 2
HD in Civil Engineering

21

CSE3032 STRUCTURAL & TALL BUILDING

Example 2.2 Continuous Two-Way Spanning Slabs

The part floor plan for an office building is shown in Figure 2.15. It is a monolithic construction and the slabs are restrained by the integral beams. The slab is 175 mm thick and is subjected to the following loading.
Characteristic D.L. Slab self-weight Finishes = 25 mm thick screed (Unit weight of screed = 20 kN/m3) Partition load = 1 kN/m2 Services = 0.5 kN/m2 Ceiling load = 0.5 kN/m2 Characteristic L.L. L.L. on slab = 3 kN/m2

Design the corner slab using grade 35 concrete and grade 460 reinforcement. Nominal cover = 25 mm.

6m

6m

Figure 2.15 - Part Plan of an Office Building

5m

5m

Chapter 2
HD in Civil Engineering

22

CSE3032 STRUCTURAL & TALL BUILDING

Solution D.L. Slab self-weight = 0.175*24 Finishes = 0.025*20 Partition Services Ceiling load Total L.L. Slab

= 4.2 kN/m2 = 0.5 kN/m2 = 1 kN/m2 = 0.5 kN/m2 = 0.5 kN/m2 =6.7 kN/m2 = 3 kN/m2

Design Load n = 1.4*6.7 + 1.6*3 = 14.2 kN/m2


ly lx = 6 = 1.2 5

From table 6.6, the moment coefficients are: Negative moment at continuous edge sx = 0.063, Positive moment at mid-span sx = 0.047,

sy = 0.045 sy = 0.034

The corner slab is divided into middle strips and edge strips as shown below.

6m 0.625m 0.75m X
5 (0.047) 3 4 (-0.045) 2 (0.034)

4.5m

0.75m Y

3.75m 0.625m

(-0.063)

Chapter 2
HD in Civil Engineering

23

CSE3032 STRUCTURAL & TALL BUILDING

Effective depth of short and long spans: Short span direction: d1 = 175 25 10/2 = 145 mm Long span direction: d2 = 175 25 10 10/2 = 135 mm Bending in Short Span Direction (lx):

Positive moment (position 3): msx = sx*n*lx2 = 0.047*14.2*52 = 16.7 kNm msx 16.7 *10 6 = = 0.023 < 0.156 bd 2 f cu 103 *145 2 * 35 From design table 1 z = 0.95d = 0.95*145 = 137 mm

As =

M 16.7 *10 6 = = 305 mm 2 / m 0.87 f y z 0.87 * 460 *137

Provide T10-225 c/c Bottom (As = 349 mm2)


100 As 100 * 349 = = 0.20 1000 *175 bh > 0.13 < 4.0 O.K.

Negative moment (position 1): msx = sx*n*lx2 = -0.063*14.2*52 = -22.4 kNm msx 22.4 *10 6 = = 0.030 < 0.156 bd 2 f cu 103 *145 2 * 35 From design table 1 z = 0.95d = 0.95*145 = 137 mm

M 22.4 *10 6 As = = = 409 mm 2 / m 0.87 f y z 0.87 * 460 *137


Provide T10-175 c/c Top (As = 449 mm2)

100 As 100 * 449 = = 0.26 1000 *175 bh

> 0.13 < 4.0 O.K.

Chapter 2
HD in Civil Engineering

24

CSE3032 STRUCTURAL & TALL BUILDING

Bending in Long Span Direction (ly):

Positive moment (position 2): msy = sy*n*lx2 = 0.034*14.2*52 = 12.1 kNm msy 12.1 *10 6 = = 0.019 < 0.156 bd 2 f cu 103 *135 2 * 35 From design table 1, z = 0.95d = 0.95*135 = 128 mm As = M 12.1*10 6 = = 236 mm 2 / m 0.87 f y z 0.87 * 460 *128

Provide T10-325 c/c Bottom (As = 242 mm2) 100 As 100 * 242 = = 0.14 bh 1000 *175 > 0.13 < 4.0 O.K.

Negative moment (position 4): msy = sy*n*lx2 = -0.045*14.2*52 = -16.0 kNm msy 16 *10 6 = = 0.025 < 0.156 bd 2 f cu 103 *135 2 * 35 From design table 1, z = 0.95d = 0.95*135 = 128 mm M 16 *10 6 As = = = 312 mm 2 / m 0.87 f y z 0.87 * 460 *128 Provide T10-250 c/c Top (As = 314 mm2) 100 As 100 * 314 = = 0.18 1000 *175 bh > 0.13 < 4.0 O.K.

Bending reinforcement at positions 5 & 6 A minimum of 50% bending reinforcement at the mid-span of position 3 and position 2 is required for the top reinforcement at position 5 and position 6 respectively. However this amount of reinforcement is less than 0.13%, T10 325 c/c top is provided at position 5 & 6.

Chapter 2
HD in Civil Engineering

25

CSE3032 STRUCTURAL & TALL BUILDING

Shear forces and shear resistance Shear forces coefficients are obtained from Table 6.7

Position 1, d = 145 mm

Vsx = vx n l x = 0.47*14.2*5 = 33.4 kN/m


33.4 *103 v= 3 = 0.23 N/mm 2 10 *145

100 As 100 * 449 = = 0.31 bd 1000 *145 35 3 From table 6.3, vc = 0.55 * = 0.62 N/mm 2 > v = 0.23 N/mm 2 25 No shear reinforcement required. Position 4, d = 135 mm Vsy = vy n l x = 0.40*14.2*5 = 28.4 kN/m
28.4 *103 v= 3 = 0.21 N/mm 2 10 *135
1

100 As 100 * 314 = = 0.23 bd 1000 *135 From table 6.3, vc = 0.51* = 0.57 N/mm 2 > v = 0.21 N/mm 2 25 No shear reinforcement required. Position 5 (d = 145 mm) , Position 6 (d = 135 mm) Vsx = vx n l x = 0.31*14.2*5 = 22.0 kN/m (Position 5) Vsy = vy n l x = 0.26*14.2*5 = 18.5 kN/m (Position 6) As positions 5 & 6 have the same amount of bending reinforcement i.e. T10-325 c/c (based on the top reinforcement), shear check for position 5 only is required.
1 35 3

Chapter 2
HD in Civil Engineering

26

CSE3032 STRUCTURAL & TALL BUILDING

22 *103 v= 3 = 0.15 N/mm 2 10 *145 100 As 100 * 242 = = 0.17 bd 1000 *145 35 3 From table 6.3, vc = 0.45 * = 0.50 N/mm 2 > v = 0.15 N/mm 2 25 No shear reinforcement required.
Torsion Steel Torsion steel of length 5/5 = 1.0 m is to be provided in the top and bottom of the slab at the three external corners marked X and Y.
1

(i) Corner X The area of torsion steel is 0.75*305 = 229 mm2 Provide the min. steel T10-325 c/c (As = 242 mm2) (ii) Corner Y The area of torsion steel is 0.5*229 = 114.5 mm2 Provide the min. steel T10-325 c/c (As = 242 mm2) Edge Strips Provide min. steel T10-325 c/c.
Deflection Use steel at mid-span and d = 145 mm

Basic l/d ratio (Table 7.3) = 23 M.F. for tension reinforcement (table 7.4) msx 16.7 *10 6 = = 0.794 bd 2 1000 *145 2 As , req 1 305 2 2 fs = f y = 460 = 268 N/mm 2 As , prov b 3 349 3 mt = 1.58 Allowable l/d ratio = 23*1.58 = 36.3 Actual l/d ratio = 5000/145 = 34.5 < 36.3

O.K.

Chapter 2
HD in Civil Engineering

27

CSE3032 STRUCTURAL & TALL BUILDING

2.3 Ribbed Slabs2 Ribbed slabs are more economical than solid slabs for long spans with relatively light loads. Two principal methods of construction are:

Ribbed slabs without permanent blocks Ribbed slabs with permanent hollow or solid blocks The topping or concrete floor panels between ribs may or may not be considered to contribute to the strength of the slab. The hollow or solid blocks may also be counted in assessing the strength using the rules given in the code. The design of slabs with topping taken into account but without permanent blocks is discussed here.
2.3.1 Ribbed Slab Proportions Proportions for ribbed slabs without permanent blocks are given in Clause 6.1.4 of the code.

In situ ribs should be spaced at centers not exceeding 1.5m. The depth of rib, excluding any topping should not exceed four times their width. The minimum width of rib will be determined by considerations of cover, bar spacing and fire resistance requirements. From practical point of view, the minimum rib width is 125 mm. The minimum thickness of topping shall not be less than 50 mm or one-tenth of clear distance between ribs whichever is greater.

< 50
> 4bv

> 1.5 m bv < 125 mm


Figure 2.16 Proportions of Ribbed Slab

Chapter 2
HD in Civil Engineering

28

CSE3032 STRUCTURAL & TALL BUILDING

2.3.2

Design Procedure and Reinforcement

2.3.2.1 Analysis of Ribbed Slabs The moments and forces due to design ultimate loads on continuous slabs may be obtained by any of the methods given in cl. 6.1.3.2 of the code for solid slabs. The coefficients of Table 6.4 may be used for the design of one-way spanning continuous rib slab.

Table 6.4 Ultimate Bending Moment and Shear Forces in One-Way Spanning Slab5 2.3.2.2 Bending The mid-span of a ribbed slab shall be designed as a T-beam, to resist sagging moment, with flange width determined in accordance with cl. 5.2.1.2 (a). At the support, the ribbed slab shall be designed as a rectangular section to resist the hogging moment. Moment reinforcement consisting of one or more bars is provided in the top and bottom of the ribs. 2.3.2.3 Shear The design of shear reinforcement is similar to that of solid slabs. 2.3.2.4 Reinforcement in the Topping A single layer of welded steel fabric, having a cross-sectional area of not less than 0.12% of the topping, shall be provided in each direction. The spacing between wires should not be greater than half the center-to-center distance between ribs.

Chapter 2
HD in Civil Engineering

29

CSE3032 STRUCTURAL & TALL BUILDING

Figure 5.2 Effective Flange Width Parameters5

Chapter 2
HD in Civil Engineering

30

CSE3032 STRUCTURAL & TALL BUILDING

Example 2.3 Design of Ribbed Slab

The ribbed floor is constructed without permanent blocks. It is continuous over several equal spans of 5.5 m. The effective section is shown in Figure 2.17. The characteristic dead load including self-weight and finishes is 4.5 kN/m2 and the characteristic imposed load is 3 kN/m2. Grade 35 concrete and grade 460 steel are used for the design. Design the end span of the ribbed slab.

70 230 195 130

400

130 Figure 2.17

Solution

Design load = (0.13 + 0.4*2/2)(1.4*4.5 + 1.6*3) = 5.88 kN/m Ultimate load F on ONE span = 5.88*5.5 = 32.3 kN
Bending: Bending moment coefficients are obtained from Table 6.4

At end span (Design as T-beam) M = 0.086FL = 0.086*32.3*5.5 = 15.3 kNm

beff = beff ,i + bw beff, 1 = 0.2*200 +0.1*(0.85*5500) = 507.5 mm < 0.2*(0.85*5500) = 935 mm beff, 1 = beff, 2 = 200 mm and beff, 1 200 mm, Hence beff = 200 + 200 + 130 = 530 mm M 15.3 *10 6 = = 0.022 < 0.132 ( b = 0.8) bd 2 f cu 530 *195 2 * 35

Chapter 2
HD in Civil Engineering

31

CSE3032 STRUCTURAL & TALL BUILDING

From design table 1, z = 0.95d = 0.95*195 = 185 mm. h f 70 = = 35mm d z = 195 185 = 10 mm < 2 2 Thus stress block lies within the flange. M 15.3 *10 6 As = = = 207 mm 2 0.87 f y z 0.87 * 460 *185

Provide 2T12 bars in the ribs (As = 226 mm2) (Design table 2) At 1st interior support (Design as rectangular beam with 130 mm width) M = -0.086FL = -0.086*32.3*5.5 = -15.3 kNm 15.3 *10 6 M = = 0.088 < 0.132 ( b = 0.8) bd 2 f cu 130 *1952 * 35 From design table 1, z = 0.890d = 0.890*195 = 173 mm. M 15.3 *10 6 As = = = 221 mm 2 0.87 f y z 0.87 * 460 *173 Provide 2T12 bars in the ribs (As = 226 mm2) (Design table 2)
Deflection: At end span: Basic l/d ratio (Table 7.3) = 18.5

(bw / b = 130/530 = 0.245 < 0.3)

M.F. for tension reinforcement (table 7.4) M 15.3 *10 6 = = 0.759 bd 2 530 *1952 2 207 f s = * 460 * = 281 N/mm 2 3 226 mt = 1.53 Allowable l/d ratio = 18.5*1.53 = 28.3 Actual l/d ratio = 5500/195 = 28.2 < 28.3 O.K.

Chapter 2
HD in Civil Engineering

32

CSE3032 STRUCTURAL & TALL BUILDING

Shear

Shear force coefficients are obtained from table 6.4. Max. shear force V= 0.6*32.3 = 19.4 kN Shear stress v = 19.4*103 / (130*195) = 0.77 N/mm2 100 As 100 * 226 = = 0.891 bd 130 *195 35 3 From design table 6.3, vc = 0.73 x N/mm2 = 0.81 N/mm2 25 > 0.77 N/mm2 No shear reinforcement required.
1

Chapter 2
HD in Civil Engineering

33

CSE3032 STRUCTURAL & TALL BUILDING

Revision

Read reference 1 on P.178 - 209.


Main Reference

1.

Reinforced Concrete Design, 5th Edition, W.H. Mosley, J.H. Bungey & R. Hulse, Palgrave. Reinforced Concrete Design Theory and Examples, 2nd Edition, T.J. MacGinley & B.S. Choo, E & FN Spon. Reinforced Concrete Design to BS 8110, Simply Explained, A.H. Allen, E & FN Spon. Design of Reinforced Concrete Flat Slabs to BS 8110, CIRIA Report 110, CIRIA. Code of Practice for Structural Use of Concrete 2004, Buildings Department, HKSAR. Tall Building Structures Analysis and Design, Bryan Stafford Smith, Alex Coull, John Wiley & Sons, Inc.

2.

3.

4.

5.

6.

Chapter 2
HD in Civil Engineering

34

CSE3032 STRUCTURAL & TALL BUILDING

TUTORIAL 2A

Q1.

A simply supported R.C. slab 175 mm thick is spanning in two directions. The effective span in each direction of the two-way spanning slab is 4 m and 5 m. The slab supports the following loading:Characteristic Dead Load Self-weight 20 mm thick finishes (unit weight = 20 kN/m3) Ceiling load = 0.5 kN/m2 Partition = 1.0 kN/m2 Characteristic Imposed Load = 5 kN/m2 Design the bending and shear reinforcement for the slab. Check the adequacy of the slab section against deflection by span-effective depth ratio approach. The characteristic material strengths are fcu = 35 N/mm2 and fy = 460 N/mm2. Nominal cover = 30 mm. Main bars assumed to be 10 mm.

Q2.

The continuous two-way spanning slabs in Figure Q2 are 150 mm thick and are restrained by integral beams. Design the slab groups 1, 2, 3 & 4. The slabs are subjected to loading as in Q1. The characteristic material strengths are fcu = 35 N/mm2 and fy = 460 N/mm2. Nominal cover = 25 mm. Main bars assumed to be 10 mm.

Q3.

A four-span R.C. ribbed slab, with spans of 6.5 m, has an effective section as shown in Figure Q3. The ribbed slab is constructed without permanent blocks. The slab is subjected to the following loadings:Characteristic Dead Load Self-weight 25 mm thick finishes (unit weight = 20 kN/m3) Services = 0.75 kN/m2 Partition load = 1.0 kN/m2 Characteristic Imposed Load = 3 kN/m2 Grade 35 concrete and grade 460 steel are used for the design. Nominal cover = 30 mm. Design the four-span ribbed slab.

Chapter 2
HD in Civil Engineering

35

CSE3032 STRUCTURAL & TALL BUILDING

TUTORIAL 2A

Q5.

A slab 250 mm thick is constructed with grade 35 concrete and is reinforced with T12-200 c/c in one direction and T12-300 c/c in the other direction. Determine the maximum load that can be carried on an area 300 * 300 mm, without the exceeding the ultimate shear stress. Nominal cover = 25 mm

Q6.

A 250 mm thick slab of grade 35 concrete is reinforced with T12-200 c/c in one direction and T12-300 c/c in the other direction. The slab is subjected to an ultimate concentrated load of 600 kN over a square area of 300*300 mm. Determine the shear reinforcement required for fyv = 250 N/mm2 and the nominal cover to reinforcement = 25 mm.

Chapter 2
HD in Civil Engineering

36

CSE3032 STRUCTURAL & TALL BUILDING

TUTORIAL 2A

4m

4m

4m

1 5m

(150)

3 5m

1 5m

Figure Q2

Chapter 2
HD in Civil Engineering

37

CSE3032 STRUCTURAL & TALL BUILDING

TUTORIAL 2A

80 275 175 500 175 500 175

Figure Q3

6.4m

6.4m

6.4m

Internal Panel

75 250 140 500 140 500

Figure Q4

5.76m
Chapter 2
HD in Civil Engineering

5.76m

5.76m

38

You might also like