Specification Data Sheet Double Block & Vent Gas Safety Shutoff Valve Systems Series T4100C, T4150C,

T4200C
Customer:________________________________________________ Inquiry /P.O.___________________________ Quantity: ______________

Location:_______________________________________________________________

Model Number:

! T4100C One Inch Cast Steel Body with 3/4 Vent ! T4150C One & half Inch Cast Steel Body with 3/4 Vent ! T4200C Two Inch Cast Steel Body with 1 Vent ! Factory Mutual ! No approval required ! Butt Weld ! Socketweld* ! MNPT* (schedule 80 only)

Agency Approval: End Connection Type:

! Spigot End ! ANSI Class 150# Flanges* ! Schedule 40 ! Right to Left ! Buna-N (Standard) ! Pneumatic ! Fail Closed

Pipe Schedule: Flow Direction: Valve Seal Material: Actuator: Failure Position: Solenoid Coil Voltage:

! Schedule 80 ! Left to Right ! Viton (Consult Factory)*

! Fail in Last Position (Non-FM approved)

! 110VAC ! 220VAC ! 125VDC ! 48VDC ! 24VDC ! 12VDC ! Special Voltage (Consult Factory, Non-FM Approved) ! SPDT ! No (Standard) ! No (Standard) ! DPDT (must be externally mounted) ! Yes* (Includes Pressure Gauge) ! Yes* (Consult Factory, Non-FM approved)

Limit Switch Type: Filter Regulator: Junction Box: Auxiliary Limit Switch: External Switches:

! Open Limit Switch* ! Inlet POC Switch* (T4150C, T4200C only) ! Externally mounted* (Applies to SPDT Only) ! Non Hazardous (Nema 4) ! Class 1 Division 2* (Nema 7) ! Class 1 Division 1*

Hazardous Area Classification:

* Price Adder Notes:

36

Specification Data Sheet Double Block & Vent Gas Safety Shutoff Valve Systems Series T4200F (2) through T4600F (6)
Customer:_______________________________________________________ Inquiry /P.O.____________________ Quantity: _______________

Location:_______________________________________________________________

Model Number:

! ! ! !

T4200F T4300F T4400F T4600F

Two Inch Fabricated Body, 1 vent Three Inch Fabricated Body, 1 1/4 vent Four Inch Fabricated Body, 2 vent Six Inch Fabricated Body, 2 1/2 vent ! No approval required

Agency Approval: End Connection Type:

! Factory Mutual

! ANSI Class 150# Flanges(Standard) ! Spigot (Sch 40) ! Butt Weld (Sch 40) ! 6 Reducing Flange on 4 * ! Outlet 0 Degrees from Inlet ! Outlet 90 Degrees from Inlet ! Outlet 180 Degrees from Inlet ! Outlet 270 Degrees from Inlet ! Special (Consult Factory with Specific Needs) ! FNPT ! ANSI Class 150# Flange* ! 0 Degrees from Inlet ! 90 Degrees from Inlet ! 180 Degrees from Inlet ! 270 Degrees from Inlet ! Special (Consult Factory with Specific Needs) ! Fail Closed ! Buna (Standard) ! Fail in Last (Non-FM approved) ! Viton*

Inlet / Outlet Flow Orientation:

Vent Connection Type: Vent Orientation:

Valve Failure Position: Valve Seal Material: Solenoid Coil Voltage:

! 110VAC ! 220VAC ! 125VDC ! 48VDC ! 24VDC ! 12VDC ! Special Voltage (Consult Factory, Non-FM Approved) ! SPDT ! DPDT ! SPDT GO Proximity* ! Yes* ! Yes* ! NEMA 4 (Painted Steel) ! NEMA 4X (Al Junction Box, S.S. Switches)* ! No (Standard) ! No (Standard)

Limit Switch Type: Open Limit Switch: Filter Regulator:

Junction Box/Switch/Solenoid Rating: (Ingress Protection) Junction Box Orientation:

! Junction Box 0 Degrees from Inlet ! Junction Box 90 Degrees from Inlet ! Junction Box 180 Degrees from Inlet ! Junction Box 270 Degrees from Inlet ! Special (Consult Factory) Note: Junction Box cannot be in same orientation as Vent

Hazardous Area Classification: ! Non Hazardous (Nema 4) ! Class 1 Division 2* (Nema 7) ! Class 1 Division 1* (Consult Factory, No Junction Box or Conduit Runs Supplied) Ambient Temperature: Outlet Test Port: Wire Gauge: Wire Termination: Closure Speed: * Price Adder 37 ! Standard (-20 F to 140 F) ! No (Standard) ! High Temperature (141 F to 180 F) (Non-FM Approved)

! OTP* (1/2 NPT port on outlet pipe)

Special Mounting Bracket: ! No (Standard) ! Special Mounting Bracket* (Consult Factory with application needs) ! AWG 16 (Standard) ! AWG 14* ! None (Standard) ! Spade Connector* ! Full Ring Lug* ! NA (Not Applicable, No Solenoid) ! STD (< 5 seconds) ! 1S* (< 1 second)

Specification Data Sheet Oil Fired Burner or Igniter Safety Shutoff Valve Systems Series T500, T1000, T2000
Customer: _______________________________________________ Inquiry / P.O. # : _________________________

Location: _________________________________________________________ Quantity: ________________________ Model Number: Agency Approval: End Connection Size: ! T500 Oil Valve ! Factory Mutual ! T1000 Oil Valve ! T2000 Oil Valve (Mechanically Atomized)

! No approval required

! 1/2 (T500) ! 3/4 (T1000/2000) ! 1 (T1000/2000)

End Connection Type: ! Spigot ! Butt Weld ! Socket Weld* ! MNPT* (Schedule 80 only) ! ANSI 300# Flanged * (T1000 only) ! ANSI 600# Flanged * (T2000 only) ! Special Configuration (Consult Factory with needs) * Pipe Schedule: Fuel Pressure Rating: ! Schedule 40 ! Schedule 80 ! 1400 PSI (T2000/Electrohydraulic)

! 300 PSI (Standard) ! 600 PSI (T2000/Pneumatic) ! Special (Consult Factory) ! 450 F (Standard)

Steam Temperature Rating: Trim Option: Flow Direction:

! Special (Consult Factory) *

! Standard ! Left to Right

! Cooling Steam / Air Seat Ring * ! Right to Left ! NEMA 4 (Painted Steel) ! NEMA 4X * (Al J-Box, S.S. Switches) ! Yes, Optional S.S. * ! None ! None

Junction Box/Switch/Solenoid Rating: (Ingress Protection) Junction Box: Actuator Type:

! Yes, (Standard; Nema 4 CS, Nema 4X Al) ! Yes, Optional Al * ! Pneumatic

! Electrohydraulic (T1000/T2000 Only)

Valve Failure Position: ! Fail Closed (Safe) ! Fail in Last Position (Non-FM approved) ! Fail in Last Fire Solenoid/Fail Closed Purege Solenoid Actuator / Solenoid Seal Material: ! Buna (Standard) ! Viton * (Recommended for High Ambient Temp.) Solenoid Supply Voltage: ! No Solenoid ! 110VAC ! 220VAC ! 125VDC ! 120VDC ! 48VDC ! Special (Consult Factory, Non-FM Approved) ! 110VAC ! 220VAC ! 24VDC ! 12VDC

Electrohydraulic Actuator Voltage:

Hazardous Area Classification: ! Non Hazardous (Nema 4) ! Class 1 Division 2 * (Nema 7,T1000/T2000 Pneumatic Actuators Only) ! Class 1 Division 1 * (Consult Factory, No Junction Box or Conduit Runs Supplied) Limit Switch Type: ! SPDT ! DPDT ! SPDT GO Proximity (Non-FM Approved) *

Ambient Temperature: ! Standard (-20 F to 140 F Pneu. Act.; 175 F Electrohydraulic Act.) ! High Temperature (141 F to 180 F Pneumatic Actuators Only; Non-FM Approved) Filter Regulator: Speed Control: Rack: Wire Gauge: Wire Termination: * Price Adder 38 ! No (Standard) ! No (Standard) ! No (Standard) ! Bracket Only * ! AWG 16 (Standard) ! None (Standard) ! Yes * (Includes Pressure Gauge) ! Yes * ! Single Valve * ! AWG 14 * ! Spade Connector * ! Full Ring Lug * ! Multiple Valve * (Consult Factory)