You are on page 1of 8

Inverter planning

Wednesday, February 06, 2013

For Facility Project number Customer

Planner Company Agent

Notes

Siemens SINVERT Select V2.5.1.1_0.3.4603.22450

Page 1 of 4

*Important note: This economic data comprises estimated values based on calculation models. Siemens does not accept liability for any deviations between the specified economic data and the actually achieved values. Deviations may be the result of various factors such as the actual weather situation, technical tolerances of the plant components or soiling of the modules. In all other respects we refer to the technical performance description of the software. As stipulated in the BDEW Guideline "Generating Plants in the Medium-Voltage Grid", a power factor (cos phi) of 0.95 and a line voltage of 95% UAC need to be taken into consideration with regard to active power when dimensioning the PV array of the inverter. For the line voltage the data sheet values with regard to rated power and max. current have to be taken into account.

Planning assumptions
Location Location Country Brasov Romania

Azimuth Module orientation

0 35

Deviation from south Deviation from the horizontal

Photovoltaic modules Manufacturer Module type G-Tec-Solar GmbH GTS72MB (300W)

Technical data

Rated power (STC) Module efficiency MPP voltage (Umpp) MPP current Open-circuit voltage (Uoc) Short-circuit current (Isc) Max. system voltage Voltage coefficient Uoc Voltage coefficient Umpp Current coefficient Isc Length Width Module type

300 Wp 15.5 % 35.8 V 8.38 A 45.4 V 8.63 A 1,000 V -139.38 mV/K -0.31 %/K -109.91 mV/K -0.31 %/K 3.37 mA/K 0.039 %/K 1,956 mm 992 mm Monocrystalline

Siemens SINVERT Select V2.5.1.1_0.3.4603.22450

Page 2 of 4

*Important note: This economic data comprises estimated values based on calculation models. Siemens does not accept liability for any deviations between the specified economic data and the actually achieved values. Deviations may be the result of various factors such as the actual weather situation, technical tolerances of the plant components or soiling of the modules. In all other respects we refer to the technical performance description of the software. As stipulated in the BDEW Guideline "Generating Plants in the Medium-Voltage Grid", a power factor (cos phi) of 0.95 and a line voltage of 95% UAC need to be taken into consideration with regard to active power when dimensioning the PV array of the inverter. For the line voltage the data sheet values with regard to rated power and max. current have to be taken into account.

Plant dimensioning
Autom. Central Solution 1 (manually adapted)

Plant overview Mains frequency cos phi Inverter type 50 Hz 1.00 2 piece(s)

SINVERT PVS2520 600Series IEC 50Hz M3S

Economic data* Energy yield/year Performance ratio Dimensioning factor 6,144.3 MWh 84.8 % 91.5 %

Photovoltaic generator Total rated power (STC) Total area of modules Number of modules 4,611.3 kWp 29,825.2 m 15,371

Plant details (PV field 1) SINVERT PVS2520 600Series IEC Number of inverters Total number of strings Modules per string Min. Umpp Max. Umpp Uoc I total I per input P max (DC) (min. 570 V) (max. 750 V) (max. 1,000 V) (max. 4,416.0 A) (max. 368.0 A) (max. 2,572 kW) 2 809 19 575 V 677 V 1,008 V 3,705.4 A 310.3 A 2,407 kW
1)

Environmental conditions Min. cell temperature Max. cell temperature Dimensioning temperature (cells) Insolation -30 C 70 C 25 C 1040 W/m

Cable losses Power loss DC side Power loss AC side 1.0 % 0.2 %

Important notes
1) NOTICE! The maximum permissible system voltage of the PV module has been exceeded: The number of set modules per string is too high or the set min. cell temperature is too low!

Siemens SINVERT Select V2.5.1.1_0.3.4603.22450

Page 3 of 4

*Important note: This economic data comprises estimated values based on calculation models. Siemens does not accept liability for any deviations between the specified economic data and the actually achieved values. Deviations may be the result of various factors such as the actual weather situation, technical tolerances of the plant components or soiling of the modules. In all other respects we refer to the technical performance description of the software. As stipulated in the BDEW Guideline "Generating Plants in the Medium-Voltage Grid", a power factor (cos phi) of 0.95 and a line voltage of 95% UAC need to be taken into consideration with regard to active power when dimensioning the PV array of the inverter. For the line voltage the data sheet values with regard to rated power and max. current have to be taken into account.

Ordering list
Autom. Central Solution 1 (manually adapted)

Item 1 2 3 4

Designation SINVERT PVS2520 600Series IEC 50Hz M3S 1000V option 600Series M3S Cabinet heating 600Series M3S Symmetry monitoring 600Series M3S

Order number 6AG3111-1AH30-8AB0 6AG3911-3GA30-0AH0 6AH3911-3HA30-1AH0 6AG3911-3EA30-0AH0

Quantity 2 2 2 2

Siemens SINVERT Select V2.5.1.1_0.3.4603.22450

Page 4 of 4

*Important note: This economic data comprises estimated values based on calculation models. Siemens does not accept liability for any deviations between the specified economic data and the actually achieved values. Deviations may be the result of various factors such as the actual weather situation, technical tolerances of the plant components or soiling of the modules. In all other respects we refer to the technical performance description of the software. As stipulated in the BDEW Guideline "Generating Plants in the Medium-Voltage Grid", a power factor (cos phi) of 0.95 and a line voltage of 95% UAC need to be taken into consideration with regard to active power when dimensioning the PV array of the inverter. For the line voltage the data sheet values with regard to rated power and max. current have to be taken into account.

Product data sheet

6AG3111-1AH30-8AB0
SINVERT PVS2520 PV-INVERTER, 600SERIES, IEC 50HZ, 3P NOM. ACTIVE POWER (AC): 2520KVA GRID CONNECT. MV TRANS, MPP-RANGE: 570-750V, UMAX 820VDC, 12 DC-INPUTS, IP20, AIR COOLING, INVERTER UNIT AMOUNT: 4, OPTIONS AVAILABLE. FOR: 1000V-OPTION (UDCMAX 1000V), PV FIELD POSITIVE GROUNDING, PV FIELD MINUS GROUNDING , SYMMETRY MONITORING, CABINET HEATING, SINVERT PVS WARRANTY 5 YEARS,

General technical data:


Efficiency maximum possible according to Euro according to CEC Design of PV inverter unit Number of PV inverter sub-units Type of installation Protection class IP Operating resource protection class Design of the interface / for communication A-rated sound power level / maximum Design of the display National language / at the indicator of the display / selectable Connection method for PV inverters dB % % % 98.7 98.5 98.5 master-slave combination 4 indoor installation IP20 I Ethernet 80 LCD-TFT English, German without transformer

Output (AC side):


Phase number Output voltage / on the AC side / for infeed operation nominal value minimum maximum Power factor / at nominal value of active power supplied / nominal value Power factor inductive V V V 370 314.5 407 1 3

0.8

6AG3111-1AH30-8AB0 Page 1/ 4

04/13/2012

subject to modifications Copyright Siemens AG 2012

Power factor capacitive Active power supplied / on the AC side in permanent operation / nominal value maximum Current supplied / on the AC side / maximum Line frequency / suitable for infeed operation nominal value minimum maximum Relative residual ripple / of AC current / at nominal value of the AC active power / on unloaded line / maximum Grounding concept / on the AC side Design of the overvoltage protection / on the AC side Hz Hz Hz % W W A

0.8

2,520,000 2,520,000 3,940

50 47.5 51.5 2

IT type 1/2

Input (DC side):


MPP voltage Consumed active power / on the DC side / nominal value Input voltage / on the DC side for the start of the infeed operation for possible infeed operation nominal value maximum permissible Number of inputs / on the DC side Input current / per DC input / maximum Total power used / on the DC side / maximum Overcurrent strength / per DC input / nominal value Product component / on the DC side / overvoltage protection per DC input Design of the overvoltage protection / on the DC side A A A V V V V 700 570 750 585 820 12 368 4,416 368 Yes V W 570 750 2,572,000

type 2

External auxiliary voltage supply:


Auxiliary voltage / nominal value Auxiliary voltage frequency / nominal value effective power consumed / from external auxiliary supply for infeed mode / without cabinet heating / maximum for infeed mode / with cabinet heating / maximum in night-time operating mode without cabinet heating / maximum with cabinet heating / maximum Grounding concept / for auxiliary power supply external W W 760 1,760 TN-S W W 10,600 11,600 V Hz 400 50

6AG3111-1AH30-8AB0 Page 2/ 4

04/13/2012

subject to modifications Copyright Siemens AG 2012

Ambient conditions:
Installation altitude for nominal active power maximum Incoming air temperature / at nominal value of active power supplied / maximum Ambient temperature during operating during storage during transport Relative humidity during operating phase during storage during transport Climatic class Type of cooling Cooling air flow Nature of the ventilation m/h % % % 0 95 0 95 0 95 3K3 forced-air cooling via fan 26,000 air intake cabinet front/air outlet cabinet top C C C 0 50 -25 +70 -25 +70 m m C 0 1,000 2,000 40

Mechanical data:
Width / of PV inverter subunits Height / of PV inverter subunits Depth / of PV inverter subunits Weight / of the single device Type of mounting mm mm mm kg 2,700 2,100 730 2,085 Floor mounting installation

Certificates/approvals:
Verification of suitability / CE mark Product quality for safety / EN 50178 EMC interference resistance industry according to IEC 61000-62 EMC emitted interference industry according to IEC 61000-6-4 for harmonics / IEC 61400-21 Yes Yes Yes

Yes Yes

Connections:
Design of the electrical connection / at the DC input Design of the thread / of the connection screw / at DC input Tightening torque at DC input Design of the electrical connection Nm 70 70 ring cable lug M12

6AG3111-1AH30-8AB0 Page 3/ 4

04/13/2012

subject to modifications Copyright Siemens AG 2012

at AC output for communications interface for auxiliary voltage Design of the thread / of the connection screw at AC output for auxiliary voltage Tightening torque at the AC- output for auxiliary voltage Conductor cross section that can be connected / for auxiliary voltage finely stranded AWG number / as coded connectable conductor cross-section / for auxiliary voltage finely stranded mm Nm Nm

ring cable lug Connector (RJ-45) screw connection

M12 M3

70 0.6 0.8

0.25 4

24 10

Options:
Manufacturer's part number for order option: 1000 V option for order option: PV array grounding positive pole for order option: PV array grounding negative pole for order option: symmetry monitoring 6AG3911-3GA30-0AH0 6AG3911-3FA30-0AH0 6AG3911-3FB30-0AH0 6AG3911-3EA30-0AH0

Further information:
Information- and Downloadcenter (Catalogs, Brochures,) http://www.siemens.com/sinvert-infocenter Industry Mall (Online ordering system) http://www.siemens.com/sinvert-mall Cax online generator: http://www.siemens.com/cax Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/6AG3111-1AH30-8AB0/all Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=6AG3111-1AH30-8AB0

last change:

Apr 13, 2012

6AG3111-1AH30-8AB0 Page 4/ 4

04/13/2012

subject to modifications Copyright Siemens AG 2012