MIS DEVELOPMENT PROJECT

50 m3 TREATED WATER TANK DATA SHEET


CLIENT: CNPCI/NESCO Consortium 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 C B A Rev. Aug. 8,05 Jul. 26,05 Jun. 18,05 Date Issued for Approval Issued for Approval Issued for Comments Description Fan Xixuan Fan Xixuan Fan Xixuan By Tao Lifeng Tao Lifeng Tao Lifeng Checked Lu Huanxuan Lu Huanxuan Lu Huanxuan Reviewed Zhai Feng Zhai Feng Zhai Feng Approved Total Flow: Operating Pressure: Operating Temperature: Vapor Density: Liquid Density: Code: ASME Stamp 900 Yes Yes 0.1 at at 60 Location: Service: Design Code: Vessel Size: Thickness: Vessel Type: Heads: Medium: ID. Information to be completed by: Applicable to: Proposal Purchaser Purchase Item Name: Item Tag Number: No Items: UNIT: PU & DP DOCUMENT NO.: MIS-M-DS-04052 Company Project Number: Purchase Order Number: Supplier Project Number: GENERAL Vender As Built MATERIALS Material Code: Shell: mm mm Head: Pipes: Flange: Blots: Cyclic Nuts: Gaskets: Supports: Internals: ASME Section II A516-60 A516-60 A106Gr.B A105 A193 A194-2H Spirally Wound Non-asbestos Gaskets A36 A36 Vender if not completed by Purchaser REV. C PAGE 1 OF 2

50m3 TREATED WATER TANK T-04320 1

DESIGN CRITERIA Treated Water Tank ASME Section VIII - Division 1 2800 mm mm S/S 8100 Head: Horizontal Other Type: Lethal Wet H 2S Outdoor Shell: Vertical 2:1 Ellipse Hydrogen Severe Indoor Under Shelter PROCESS DATA 67 0.08 40 m/h Mpag
o

MANUFACTURE AND TEST REQUIREMENTS Manufacturing Code: Welding Code: NDE Code: Ultrasonic: Magnetic Paricle: X-Ray Inspection Length: X-Ray NDE Grade: Hydraulic Test: Painting and Packing: ASME Section VIII-Division 1 ASME Section IX ASME Section V As Per Code As Per Code As Per Code As Per Code Yes Yes No No

kg/m kg/m No No Mpag


o o o

Board Registration: Internal Design Pressure: Top, Mpa Bottom, Mpa Design Temp: Normal Liquid Level: Max Wind Speed: Seismic Zone: Corrosion Allowance: Shell: Insulation: Type: 3 mm

C C C

As Per Specification: MIS-L-SP-03537 Corrosion Prevention: Lifting Lug: Yes Yes No No

mm 29.8 hold m/s

INTERNALS Mist Eliminator: Yes No

Heads: 3 Yes

mm

Nozzles: No

mm

Type: Vortex Breakers: Coil: Others: Yes Yes No No

Thickness:

MIS DEVELOPMENT PROJECT


50 m3 TREATED WATER TANK DATA SHEET
CLIENT: CNPCI/NESCO Consortium 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 NOTE: 1. All nozzle orientations to be defined later. 2. Reference PID: MIS-P-DW-01702. Applicable spec: MIS-M-SP-04005. Mark N1 N2 N3 N4 N5 LG1-2 MW Qty 1 1 1 1 1 2 1 Size 4" 6" 6" 6" 4" 2" 24" Type RF RF RF RF RF RF RF Rating ANSI 150 ANSI 150 ANSI 150 ANSI 150 ANSI 150 ANSI 300 ANSI 150 Breather Valve Inlet(from Produced Water Sedimentation Tank ) Inlet Outlet Drain Level Gauge Manway with Davit Type of Support: Skirt Insulation Supports: Fire Proofing Supports: Skid Mounted: Manway Davit/Hinge: Ladder: Platform: Legs Saddle Yes Yes Yes Yes Yes Yes Lugs No No No No No No NOZZLES Service ATTACHMENT Empty Weight: Operating Weight: Weight Filled With Water: Dimension: L x W x H: mm UNIT: PU & DP DOCUMENT NO.: MIS-M-DS-04052 REV. C PAGE 2 OF 2

WEIGHT AND DIMENSION By Vendor By Vendor By Vendor kg kg kg