INSTALLATION GUIDE

S I N G L E E X PA N S I O N B O LT S (FBN II)
Drill the hole through the pre-drilled hole in the fixture into the concrete. This hole should be drilled perpendicular to the substrate surface and to the correct diameter and depth. All dust and loose material should be removed from the hole using a wire brush or blow pump.

ETA-07/0211 ETAG 001- 2


Option 7 for non-cracked concrete

DRILL HOLE & REMOVE DEBRIS

Lightly tap the throughbolt through the fixture into the hole with a hammer, until the fixing depth is reached.

INSERT BOLT

Tighten to the recommended torque.

BEFORE I N S T A L L A T I O N
The following checks must be carried out prior to installation of Single Expansion Bolts. 1. The appropriate length and diameter drill bit is used. 2. The correct edge distance and spacing are used in accordance with the design requirements. 3. The anchor/fixing is the correct size. 4. The correct setting tools are used.

TIGHTEN BOLT

Single Expansion Bolts Bolt Reference Thread Size Overall Length (mm) Hole Dia. in Concrete (mm) Hole Dia. in Fixture (mm) Min. Embedment (mm) Width Across Nut (mm) Tightening Torque (Nm) Max. Fixing Thickness (mm) FBNII 6/10 M6 55 6 6.5 30 10 4 10 FBNII 8/10 M8 71 8 9 40 13 10 10 FBNII 10/20 M10 96 10 11 50 17 20 20 FBNII 10/50 M10 126 10 11 50 17 20 50 FBNII 12/20 M12 116 12 13 65 19 35 20 FBNII 12/50 M12 146 12 13 65 19 35 50 FBNII 16/25 M16 145 16 17 80 24 80 25 FBNII 16/50 M16 170 16 17 80 24 80 50

Note: For use in non-cracked concrete C20/25 to C50/60. July 2013 Page 1 of 2

abc
INSTALLATION GUIDE

H I G H P E R F O R M A N C E B O LT S ( FA Z I I )
Drill the hole through the pre-drilled hole in the fixture into the concrete. This hole should be drilled perpendicular to the substrate surface and to the correct diameter and depth. All dust and loose material should be removed from the hole using a wire brush or blow pump.

ETA-05/0069 ETAG 001- 2


Option 1 for cracked concrete

DRILL HOLE & REMOVE DEBRIS

Insert the bolt through the component to be fixed and into the concrete. Add any packing shims that maybe required.

INSERT BOLT

Tighten to the recommended torque.

BEFORE I N S T A L L A T I O N
The following checks must be carried out prior to installation of High Performance Bolts. 1. The appropriate length and diameter drill bit is used. 2. The correct edge distance and spacing are used in accordance with the design requirements. 3. The anchor/fixing is the correct size. 4. The correct setting tools are used.

TIGHTEN BOLT

High Performance Expansion Bolts Bolt Reference Thread Size Overall Length (mm) Hole Dia in Concrete (mm) Hole Dia in Fixture (mm) Min. Embedment (mm) Width Across Nut (mm) Tightening Torque (Nm) Max. Fixing Thickness (mm) FAZII 8/10 M8 75 8 9 45 13 20 10 FAZII 10/10 M10 95 10 11 60 17 45 10 FAZII 10/30 M10 115 10 11 60 17 45 30 FAZII 12/30 M12 130 12 13 70 19 60 30 FAZII 12/50 M12 150 12 13 70 19 60 50 FAZII 16/25 M16 148 16 17 85 24 110 25 FAZII 16/50 M16 173 16 17 85 24 110 50

Note: For use in cracked and non-cracked concrete C20/25 to C50/60.

Ancon Building Products, 2013 The Construction applications and details provided in this guide are indicative only. In every case installation should be entrusted to appropriately qualified and experienced persons. Normal handling precautions should be taken to avoid physical injury. Ancon Building Products cannot be held responsible for any injury as a result of using our products, unless such injury arises as a result of our negligence.