You are on page 1of 4

Tower Type Site ID

45m site GAJ080 Tower assessment report

15-Jan-14

CHECK ON ANCHOR BOLT BEFORE STRENGTHEN Design Standard: ANSI/TIA-222-G & ACI-318-08 Maximum Leg Tension Leg Shear Force No. of Bolts Bolt diameter Yield strength Ultimate strength Check Anchor Bolt steel strength Tension force per bolt Shear force per bolt Rnt Detail factor Interaction T H da = = = = = = 609 68 8 25 640 800 KN KN mm N/mm2 N/mm2

= = = = =

76.1 8.5 314.2 0.55 0.29

KN KN KN < 1.0 O.K.

Pullout strength of L-anchor according to ACI 318-08 f'c Concrete cylinder strength = 20 Supplied extension of L-anchor Maximum effective extension extension value in design ehsup ehmax eh ! = = = = = = = = Pullout strength Tension force per bolt ! Npn = = = = 125 4.5 da 112.5 112.5 0.70 1.00

N/mm2 mm mm mm Condition B always applies for pullout strength Cracking may occur at the top of the pedestal under tension KN

#c,p Np

0.9 f'c eh da 50.6 ! #c,p Np 35.4 76.1 KN 2.15 Unsafe

1 of 2

Tower Type Site ID

45m site GAJ080 Tower assessment report

15-Jan-14

Check Base Plate 1st section Thickness Yield strength Force Arm Section width Elastic Modulus Plastic Modulus Bending Moment Capacity Applied Bending Moment Ratio of Usage 2nd section Thickness Yield strength Force Arm Section width Elastic Modulus Plastic Modulus Bending Moment Capacity Applied Bending Moment Ratio of Usage

= = = = = = = = =

30 250 121 370 55500 83250 18731 9211 0.492

mm N/mm2 mm mm mm3 mm3 KN.mm KN.mm < 1.0 O.K.

= = = = = = = = =

30 250 93.35 459 68850 103275 23237 14213 0.612

mm N/mm2 mm mm mm3 mm3 KN.mm KN.mm < 1.0 O.K.

2 of 2

Tower Type Site ID

45m site GAJ080 Tower assessment report

15-Jan-14

CHECK ON ANCHOR BOLT AFTER STRENGTHEN Design Standard: ANSI/TIA-222-G & ACI-318-08 Maximum Leg Tension Leg Shear Force No. of Bolts Bolt diameter Yield strength Ultimate strength Check Anchor Bolt steel strength Tension force per bolt Shear force per bolt Rnt Detail factor Interaction T H da = = = = = = 609 68 8 25 640 800 KN KN mm N/mm2 N/mm2

= = = = =

0.0 8.5 314.2 0.55 0.05

KN KN KN < 1.0 O.K.

Design of Vertical Reinforcement According to ACI-318 No. of reinforcement bars = 20 Diameter of reinforcement bars = 16 Area of reinf. bars Reinforcing bar, grade 52 Tension Capacity Applied tension Ratio of Usage As fy = = = = = 4021 360 1303 609.00 0.467

mm mm2 N/mm2 KN KN < 1.0 O.K.

Check Splice Length Of Tension Anchor With Rebar Distance between anchor and rebar = 174 Clear cover = 50 rebar spacing = 144 Pedestal top cover = 50

mm mm mm mm

where

1 of 2

Tower Type Site ID

45m site GAJ080 Tower assessment report ld db fy f 'c = = = = = = = = = = = = = 23.4 " 16 360 20 1 1 0.8 1 50.0 0 2.5 0.47 300 = mm N/mm2 375 mm

15-Jan-14

development length

reinf. location factor coating factor reinforcement size factor lightweight concrete factor spacing or cover dim. transverse reinf. index As required / As provided Reduced development length Minimum rebar embeded length supplied length

t e s

cb Ktr

N/mm2 not exceed 68 Mpa for vertical rebars, ACI 318-08 12.2.4 for uncoated reinforcement (0.8 for # 19 or smaller, 1.0 for other) for normalweight concrete mm conservative to assume Ktr = 0

(c + Ktr ) / db =

mm

ACI 318-08 12.2.5

= 466 mm = 955 mm Safe as 466 <= 955

Check Base Plate 1st section Thickness Yield strength Uniform stress Force Arm Section width Elastic Modulus Plastic Modulus Bending Moment Capacity Applied Bending Moment Ratio of Usage 2nd section Thickness Yield strength Uniform stress Force Arm Section width Elastic Modulus Plastic Modulus Bending Moment Capacity Applied Bending Moment Ratio of Usage

= = = = = = = = = =

30 250 3.01 61.691 370 55500 83250 18731 6355 0.339

mm N/mm2 N/mm2 mm mm mm3 mm3 KN.mm KN.mm < 1.0 O.K.

= = = = = = = = = =

30 250 3.01 66.78 459 68850 103275 23237 9249 0.398

mm N/mm2 N/mm2 mm mm mm3 mm3 KN.mm KN.mm < 1.0 O.K.

2 of 2