Professional Documents
Culture Documents
ventilation
(Catalogue no. 1)
Industrial and commercial ventilation
components - fans for round
and rectangular ducts,
sound-insulated, axial and roof fans,
air handling units with heat recovery,
air heating units, accessories.
Energy saving ventilation
Air handling units
(Catalogue no. 2)
Energy saving supply and
exhaust units and air handling
units with heat recovery with
air capacity up to 6500 m
3
/h.
Fire and smoke damper
KPDU
(Catalogue no. 5)
Fire dampers KPDU
for smoke protection systems
of buildings and premises.
Domestic ventilation
(Catalogue no. 6)
Domestic ventilation:
fans, mono-pipe exhaust kitchen
and bathroom fans,
air distribution units, air ducts
and fittings, access doors,
ventilation kits.
Air distribution units
(Catalogue no. 9)
Plastic and metal air distribution
products (grilles, disk valves,
diffusers, etc.) for ventilation,
air conditioning and heating.
Access doors
(Catalogue no. 10)
Plastic and metal access
doors for accessing
concealed equipment and
utility lines. Special offers
for ceramic tiles.
Spiral seam air ducts
(Catalogue no. 13)
SPIROVENT spiral seam vent ducts
and fittings of 100 to 1600 mm
diameter.
Flexible ducts and
fittings for ventilation,
air conditioning
and heating
(Catalogue no. 14)
Flexible and semi-flexible air
ducts made of polymeric
materials, aluminium,
galvanized or stainless
steel, metal fittings for
ventilation, air conditioning,
heating, gas handling and
abrasive particles
aspiration.
Air handling units
AIRVENTS
(Catalogue no. 3)
Energy saving air handling units
with air capacity up to 40 000 m
3
/h,
for use in large residential,
industrial and commercial objects.
Energy saving ventilation
Geothermal systems
GEO VENTS
(Catalogue no. 4)
Energy saving system
GEO VENTS with use of the earths
surface layers heat.
High ventilation system
energy efficiency and low
operating costs.
Domestic fans
(Catalogue no. 7)
Domestic fans with air capacity
up to 365 m
3
/h with extra functions:
timer, humidity sensor,
motion sensor, etc.
Applied for premises up to 30 m
2
.
VENTS VN
Mono-pipe exhaust
ventilation
(Catalogue no. 8)
Exhaust ventilation in houses
with mono-pipe ventilation
system based on VENTS VN fans.
Plastic grilles for ventilation
and air conditioning
(Catalogue no. 11)
PROFIPLAST extruded plastic grilles
for ventilation and air conditioning.
Metal grilles for ventilation,
air conditioning and heating
(Catalogue no. 12)
Metal grilles made of extruded
metal profile for ventilation
and air conditioning.
Flat and round PVC
air ducts
(Catalogue no. 15)
Flat and round PVC ducts
PLASTIVENT for ventilation of
residential, office and commercial
premises and connection of exhaust
ventilation equipment
(kitchen extractors, hoods,
exhaust boxes, etc).
Wide product range of fittings.
Energy saving ventilation.
Single room energy
recovery ventilators.
(Catalogue no.16)
Single room reverse ventilators with
energy regeneration for efficient
ventilation and lowest investments
in ready-built and brand new
premises.
3
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Air handling units with
heat recovery page
40
AHU schematic diagrams page
120
About us
page
4
Ventilation in our life page
6
Motor description and principle page
8
EC motor advantages page
9
Ventilation with heat recovery page
10
Air handling unit design page
12
Supply units
Exhaust units page
14
CONTENTS
4
VENTS. Air handling units | 06-2013
VENTS company was founded in the nineties of the XXth century.
Dynamic development of the enterprise and ongoing study of the
consumer demand enabled rapid international leadership of the company in
the ventilation industry.
VENTS is a powerful research and development enterprise with 2500
professionals working as a single team to ensure a full production cycle from
idea to end product. The production base of the company is located at more
than 60 000 m
2
area. It includes 16 workshops equipped under the latest
international standards and each of them is comparable to a separate plant.
Modern equipment, active implementation of advanced technologies
and highly automated production are the characteristic features of VENTS
company.
The company undergoes rapid dynamic development; fundamental
researches and effective designs in climatic equipment industry are in the
focus of the companys business strategy.
The joint cooperation of the corporate design department, test
laboratories and production workshops let us introduce high quality products
to the market.
Special attention is paid to the manufacturing of the goods during all
manufacturing stages including monitoring of the technological conditions.
Technical characteristics of supplied raw materials are thoroughly checked.
Quality control system which meets international standard requirements
ISO 9001:2000 was implemented at the enterprise.
Environmental protection is one of the basic components of the corporate
development. The technological process at the enterprise is arranged in such
a way as to exclude any negative impact to the environment. To solve the
global energy saving problem we develop a special climatic equipment that
provides comfortable conditions for people and reduces the energy demand
significantly.
Perfect quality, competitive prices, high production potential, technical
capabilities and the wide product range stimulate long-term partrnership
and product promotion all over the world.
The VENTS ventilation products are exported to more than 90 countries
and are sold through the distribution network of 120 companies worldwide.
Share of the VENTS products globally is above 10%.
VENTS is a member of high-rank international organizations, the leading
HVAC experts.
Since 2008 VENTS has been a fully-featured member of HARDI
Association (Heating, Air-conditioning and Refrigeration Distributors
International, USA).
Since 2010 VENTS has been a participant of AMCA Association (the Air
Movement and Control Association (AMCA) International, Inc.). In 2011
VENTS successfully passed tests for compliance with AMCA standards and
the VENTS products were certified for the USA market.
In 2011 VENTS joined HVI (Home Ventilation Institute, USA) Association.
WE L C OME T O T H E V E NT S WOR L D !
5
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Powerful production facilities, high automation level, active implementation of innovative technologies in the production process made VENTS a
worldwide ventilation leader.
We manufacture our products with respect to unique geographical, climatic, technical features of each country and do our best to fulfill the
client's wishes anywhere anytime.
Get benefit from cooperation with VENTS TM and enjoy the maximum range
of products of the top quality from one manufacturer.
Metal processing workshop
Powder coating workshop
Residential fans workshop
Air handling units workshop
Spiral air ducts workshop
Wet coating workshop
Ventilation grilles workshop
AirVents air handling units workshop
Flexible air ducts workshop
Extrusion workshop
Electric motors workshop
Electrical accessories workshop
Aluminium grilles and diffusers workshop
Injection moulding workshop
Industrial fans workshop
Extruded grilles workshop
6
VENTS. Air handling units | 06-2013
What Is Ventilation Required For?
There is a range of aspects to determine air quality.
Oxygen and Carbon Dioxide Concentration. Oxygen decrease and carbon
dioxide increase cause stuffiness in the premises.
Content of Harmful Substances and Dust. High content of dust, tobacco
smoke and other substances in the air badly impact human organism and can
cause various lung and skin diseases.
Odours. Bad smell causes discomfort or irritates nervous system.
Air Humidity. Increased or decreased moisture cause discomfort and even
can result in acute attacks of disease for sick people. Air humidity is important also
for the atmosphere in the premises. For instance, doors, window frames, furniture
may dry up of decreased humidity in winter; but they may expand in the premises
with increased humidity level like swimming-pools, bathrooms etc.
Air Temperature. A person feels good in a premise with the temperature
21-23C. Temperature variation causes the change of comfort feeling that
influences a persons physical and mental activity.
Air Motion. Increased air speed in the premises causes the feeling of draft,
and decreased speed causes air blanketing. We feel the impact of any of these
factors.
Solution:
Any ventilation system must include simultaneous fresh air supply and extract
air exhaust thus ensuring the ideal air balance in the room. In case of poor or
insufficient air intake from outside the oxygen content decreases and humidity
and dustiness level in the room increases. If exhaust ventilation is not provided
or it is not effective, polluted air, smells, humidity and harmful substances are
not removed. Furthermore, exhaust ventilation is not effective without supply
ventilation and none of these systems can operate independently. It is impossible
to arrange correct air exhaust from a closed vessel because removed air is not
compensated. Supply ventilation in a closed vessel system is not effective either.
Some objections can be raised with the example of an exhaust fan in the bathroom
or in the kitchen. Once it runs, the ventilation system operates. Really. It looks
like it operates. However such ventilation example shows that after extract air
is removed by the fan the flat is filled with non-arranged air flows from various
slots in the windows, doors and other building structures. Consequently dust
and odours are transported with the air flows from outside and air draught can
appear. Opened windows and doors are another way for air supply. Such way of
ventilation arranging is possible but it has some problems like abrupt temperature
lowering of the heated premises during winter time, dust and noise from outside,
insects invasion through the opened windows, draughts and sharp temperature
drop. Correct ventilation system is the only solution in this situation. Ven-
tilation system ensures filtered air supply during summer time and filtered
and heated air supply during winter time as well as removal of polluted
extract air from the premises. The joint application of supply ventilation
units to supply fresh air to the rooms jointly with exhaust fans provides
quality ventilation in your buildings.
VENTILATION
IN OUR LIFE
We are surrounded by air and breathe
in and out 20 000 litres of air every day.
How much inspired air is applicable for
the healthy life?
7
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
The issue of ventilation is the most essential subject from the point
of view of thermal energy saving permanent temperature maintain-
ing. The factors that influence the heat loss dynamics vary from wall
thermal protection to heaters and heating system quality, density of
wall panels joints and window joints as well as personal consumption
habits.
Ventilation demands up to 45% of the total heat energy consump-
tion in modern buildings. The reasons are as follows:
a) One half of air volume is exchanged through the open window
within 30-60 min. So the heat losses gorw tremendously;
b) Energy saving houses are equipped with all available facilities for
sealing and thermal insulation of the buildings. Such houses are so well
insulated that the heat loss share through the walls makes only 30 to
40% of the total amount.
Thus the ventilation induced heat losses remove 2/3 of the total
heat.
So we come to the point of providing air exchange with minimum
heat losses. From 30% to 70% of heat loss is variously estimated for
the exhaust ventilation that is traditionally for residential houses. The
controllable air exchange and heat recovery are the compulsory at-
tributes in the modern house construction that are ensured by means
of air handling units. The forced ventilation allows recuperating up to
90% of the exhaust air heat. Such effect is attained due to installa-
tion of the heat exchanger (recuperator). The heat exchanger allows
saving heat in winter period and contributes to better operation of air
conditioners jointly with ventilation in summer period. In addition the
heat exchangers have heat- and soundinsulated casing that reduces the
noise level produced by equipment in the room. As of today the ventila-
tion systems based on heat exchangers are the most state-of-the-art
and progressive solution for air exchange arranging in the premises.
Due to recuperation of the unit its owner can save good money for
operation costs. Use of the ventilation units with heat recovery jointly
with the air conditioning systems is not only the most effective way to
arrange the required microclimate in the room but to cut costs as well.
In winter the heat exchanger saves heat and in summer it saves cool.
The plate heat exchanger of cross-flow or counter-flow type is the
simpliest one as it contains no movable parts and electrical connec-
tions; it separates the air streams fully; requires no additional energy
consumption and maintenance.
Use of units with heat recovery in ventilation systems results in
shortening of payback period and improving its ecological characteris-
tics in view of low energy consumption, low investment for heat energy
generation and its distribution, careful attitude to environment.
New series of compact air handling units with EC (electronically
commutated) motors provide energy consumption reducing up to 50%
as compared to traditional asynchronous motors. Operating costs will
be generally reduced by 30%.
Fans with EC motors have the following advantages:
- efficient operation at any rotation speed of fan impeller (up to
zero) and significant winding electrical resistance;
- low heat generation that enables reducing performance losses
of refrigeration equipment and compensate for heat generation of
fan motors in case of use of EC-motor fans in conditioning systems;
- fan overall dimensions can be reduced in case of external rotor
and EC-motor design. Consequently the disadvantages related to
large-scale overall dimensions that are typical for fans with stan-
dard motors are minimized;
- the maximum motor speed does not depend upon frequency
(operation both at 50 Hz and 60 Hz is possible);
- high efficiency at low speed;
- external rotor design makes it compact.
8
VENTS. Air handling units | 06-2013
EC motors with external rotor
EC motor with external rotor is the innovative development of EBM-PAPST company
with the electronics integrated directly into the motor. The built-in electronics
ensures the full control over the energy consumption and speed rate and provides
smooth regulation and keeping of the fan parameters. Standard fans require
additional control equipment to have the similar functions. EC motors have the
energy consumption by 50% less as compared to standard models. The operating
costs for EC motors maintenance are also generally by 30% less. Premium efficiency
of EC motors reaching up to 90% is their great advantage.
Basic principle of EC motors:
- The permanent magnets integrated into the motor create magnetic field. The
above phenomena disables any thermal losses in the rotor which are common
with any squirrel-cage motor.
- change of the current direction in the stator winding is effected by means of
the integrated commutating electronics based on Hall sensor (controller) which at
any moment calculates and supplies to the stator the required for the continuous
rotor rotation polarity. Such motor design does not need any brushes requiring
regular maintenance.
- EC motors are suitable for
connection to direct-current
voltage according to the required
parameters or through the switching
module directly to AC supply (230,
400 V, 50/60 Hz).
High-powered EC motors produce
low noise level which makes their
application suitable in supermarkets,
hotels and other public facilities as
well as in residential premises.
EC systems are featured with long
service life and are designed for at least 4.5 years of continuous operation,
i.e. about 40 000 operating hours. In one line with that service maintenance is
minimized because of high reliability.
Due to a complex of considerable advantages the fans equipped with EC motors
ensure quick pay off period for owners and investors.
MOTOR DESCRIPTION AND PRINCIPLE
Fan types:
Various fan types are applied in air handling units for air transportation through air
ducts, direct air supply or air exhaust.
Centrifugal fans consist of two basic components - turbine and scroll casing.
Impeller of centrifugal fan is a hollow cylinder with mounted blades inside,
circumferentially fixed with disk plates. The hub for mounting the impeller
on the shaft is located at the center of the
strengthening ring.
During the impeller operation air is trapped
between the blades and moves radially from
the center compressed. Under centrifugal force
air is transported to the scroll casing and then
moved to the exhaust pipe.
Centrifugal fans incorporate forward- or
backward-curved blades. Use of centrifugal
impellers with backward-curved blades allows
up to 20% energy saving. Another important privilege of backward-curved blades
is their high air overload capability.
Centrifugal fans with forward-curved blades
ensure the same air capacity and pressure
characteristics as the backward-curved blades
do but they require smaller impeller diameter
and lower speed. So they are able to attain
the required result demanding less space and
producing less noise.
External rotor motors
External rotor motor design is similar to asynchronous motor design but the motor
rotor is located outside of the stator winding and the stator with the windings is
located in the motor centre. Such original modification ensures the compact size of
the unit. The motor shaft rotates on the ball bearings mounted inside the stator. The
impeller is fixed on the rotor casing. Such design provides air cooling of the electric
motor which allows using the fans in the wide temperature range. All the motors
and impellers are statically and dynamically balanced at the manufacturing facility.
Backward curved blades
Forward curved blades
9
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
EC motor advantages
COMPACT SIZE
- the systems based on EC motors provide the required operating
parameters by smaller fans due to their increased efficiency. Actually the
fans have the minimum size.
LOW ENERFY CONSUMPTION
- premium efficiency of the motor reaching up to 90% provides reducing
energy consumption at least by 30% for the same operating point
without speed control. In case of speed control the energy consumption
is by 2-8 times less!
SMOOTH AND ACCURATE SPEED CONTROL
- the fans are programmable and change the air capacity depending on
any control parameter like temperature, humidity, pressure, air quality
etc. Depending on a setting the EC motors change their rotation speed
respectively to a control parameter change and air is supplied in the
required for the system volume.
HIGH AUTOMATION DEGREE OF CONTROL PROCESS
- high automation degree of control process reduces the influence of
human factor.
INTEGRATED MOTOR PROTECTION
- prevents rotor locking, electrical and temperature overloads that
extends the equipment service life due to its resistance to change of
voltage.
FULL CONTROL
- fan operation can be controlled at any place of the Earth through
Internet.
WIDE RANGE OF SUPPLY VOLTAGE
- 200-277 V of 380-480 V 15%.
MINIMUM CROSS SECTION OF POWER CABLE AND POWER
TRANSFORMER OUTPUT
- the fans have no startup currents and for that reason they consume
much less energy as compared to the standard fans.
MINIMUM MAINTENANCE
- long-term service life (as compared to AC).
Energy-saving EC motor structure
10
VENTS. Air handling units | 06-2013
VENTILATION WITH HEAT RECOVERY
The design of the plate heat exchangers is such as to exclude transfer of
contaminants, odours and microbes from exhaust air flow to supply air flow. The
air flows are divided by wall elements of heat exchanger plates made of aluminium
or polystyrene. Thermal energy quantity that is transferred from exhaust air to
supply air depends exclusively on thermal conductivity of the applied materials and
temperature difference between two flows. So warm exhaust air is warmed up
and cold intake air is heated down.
Though moisture from warm air flow is not transferred to cold air flow, a part of
the latent heat energy from humid exhaust air is used for heat recovery. At low
outside temperatures and high exhaust air heating degree the exhaust air can be
cooled to the temperature of dew point. Consequently it produces the condensed
moisture and the latent vaporization heat is released. During this process the
temperature difference of the air flows that cross the heat exchanger is more
than that one during no condensing and that means higher total thermal energy
and consequently higher heat recovery efficiency. That is why it is so important to
provide free condensate drainage from the heat exchanger.
Use of plate heat exchangers in ventilation system results in shorter payback
period and better ecological characteristics ensuring the further advantages:
- low energy consumption;
- low investment for thermal energy generation and its distribution;
- no removable parts which means durability and long service life at continuous
operation;
- high-efficient heat recovery and little investment result in high self-repayment;
- environmental protection.
ontrollable air exchange and heat recovery are the compulsory attributes in the modern construction that are ensured by means of air handling units. The forced
ventilation allows recuperating up to 90% of the exhaust air heat. Such effect is attained due to installation of the heat exchanger (recuperator).
The plate heat exchangers of cross-flow or counter-flow type are used for heat recovery in Vents VUT ventilation units. The exhaust air in the heat exchanger transfers
the heat energy to the supply air.
Structure and principle of operation for the plate heat exchangers
Principle of operation of plate heat recovery of cross-flow type Principle of operation of plate heat recovery of counter-flow type
11
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Design and operating principle of air handling units based on VUT-600 WH EC example.
VUT-600 WH EC unit operates as follows:
Fresh cold air from outside is supplied to VUT WH EC unit through the air ducts, gets filtered and passes further through the heat exchanger from where it is supplied
to premises by means of the supply fan. Warm exhaust air from premises goes back to VUT WH EC unit through the ducts where it gets filtered, then passes again
through the heat exchanger and is exhausted outside by means of the exhaust fan. The exchange of heat energy of the warm contaminated air from the premises
with the fresh cold air from outside takes place in the heat exchanger. That reduces heat losses and consequently cuts the heating costs in winter time.
Recuperation economic analysis:
Air capacity: 500 m
3
/h
t1
intake temperature;
t2
up to 1520 m
3
/h
page
20
VENTS MPAE series supply units
Air capacity
up to 3500 m
3
/h
page
20
VENTS MPAW series supply units
Air capacity
up to 6500 m
3
/h
page
30
VENTS PAE series supply units
Air capacity
up to 3350 m
3
/h
page
30
VENTS PAW series supply units
Air capacity
up to 4100 m
3
/h
page
38
VENTS VA series exhaust units
Air capacity
up to 4450 m
3
/h
16
page 19
Series
VENTS VPA
SUPPLY UNITS
Description
The fan unit provides filtration, heating and supply of
fresh air to premises with the air capacity from 200
up to 1500 m
3
/h. All the models are compatible with
100, 125, 150, 200, 250, 315 mm round air ducts.
Casing
The casing is made of aluzink with internal heat- and
sound-insulating 25 mm layer of mineral wool.
Filter
Integrated panel G4 filter ensures sufficient supply
air purification.
Heater
Electric heating battery is designed for supply air
heating during winter and off-season time.
Fan
Centrifugal fan with backward-curved blades and
built-in overheating thermostat with automatic
restart. Some size ranges are equipped with a high-
powered fan (VPA-1). The fan motor and impeller are
dynamically balanced in two planes. The motor ball
bearings are maintenance-free and are designed for
at least 40 000 hours service life.
Control and automation
The supply unit is available in two modifications:
1. No control and automation system supplied.
Customer-defined and customer-selected control
automation system.
2. Integrated control and automation system for air
capacity control and setting supply air temperature.
The unit may be controlled from the external control
panel fixed on 10 m wire delivered as a standard.
Control and protection functions
switching the unit on/off;
maintaining supply air temperature set from the
control panel by means of triac heating capacity
regulation;
fan speed control by means of the control panel
(3 speed modes);
working-out of the required patterns during the unit
switching on and off;
the unit daily or week timer operation;
active overheating protection of heating elements;
disabling electric air heating battery operation
when the motor is not running;
electric heater overheating protection by means of
two thermostats;
filter clogging control though the differential
pressure sensor;
actuating the air damper (refer KRA);
relay input from an external sensor (humidistat, CO
2
sensor, motion sensor) to switch the fan to maximum
speed;
input for alarm fire fighting signal.
Mounting
Air supply unit can be mounted on the floor, attached
to a ceiling with a seat angle with anti-vibration
mounts or attached to a wall by means of the
brackets. The unit can be mounted either in service
spaces (balcony, storage room, underground floor,
roof space etc.) or in the main space by placing the
unit above the suspended ceiling or in the pocket.
The unit can be mounted in any position except for
the vertical one with vertical air downstream because
tubular heating elements are not allowed under the
fan. Free access to the unit shall be provided for
maintenance and filter cleaning. The service panel is
placed on the top. The control block is on the right.
Supply units with the air capacity
up to 1520 m
3
/h in the compact
sound- and heat-insulated casing
with electric heater.
LCD control panel
Series
VENTS VPA
1 - high-
powered
motor
Electric heater power [kW]
1.8; 2.4; 3.4; 3.6; 5.1; 6; 9
Air duct diameter
100; 125; 150; 200;
250; 315
Phase
1
single phase;
3
three phases
Designation key:
Integrated control system
_
no control system
LCD
integrated control
system
Accessories
17
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VPA
250-
3,6-3
VPA
250-
6,0-3
VPA
250-
9,0-3
VPA
315-
6,0-3
VPA
315-
9,0-3
VPA-1
315-
6,0-3
VPA-1
315-
9,0-3
Voltage [V / 50 Hz] 3~ 400 3~ 400
Maximum fan power [W] 194 171 296
Fan current [] 0.85 0.77 1.34
Electric heater power [kW] 3.6 6.0 9.0 6.0 9.0 6.0 9.0
Electric heater current [] 5.3 8.7 13.0 8.7 13.0 8.7 13.0
Number of electrical heating elements 3 3 3 3 3 3 3
Total unit power [kW] 3.794 6.194 9.194 6.171 9.171 6.296 9.296
Total unit current [] 6.15 9.55 13.85 9.47 13.77 10.04 14.34
Air capacity [m
3
/h] 990 1190 1520
RPM 2790 2600 2720
Noise level at 3m [dBA] 30 30 30
Transported air temperature [
C of the
heat medium.
Fan
Centrifugal double-inlet fan with forward-curved
blades and built-in overheating protection with
automatic restart. The fan motor and impeller are
dynamically balanced in two planes. The ball bearings
in the electric motor are maintenance free and
designed for at least 40000 hours operation.
Control and automation
Two options for supply unit modifications are possible:
1. No control. Customer-defined and customer-
selected automation system.
2. Integrated control and automation system for
three-speed (air capacity) control and setting supply
air temperature. The unit may be controlled from the
external control panel fixed on 10 m wire delivered as
a standard.
MPA...E control and protection functions
switching the unit on/off from the control panel;
setting the supply air temperature from the remote
Supply units with the air capacity
up to 3500 m
3
/h in the compact
sound- and heat-insulated casing
with electric heater
Supply units with the air capacity
up to 6500 m
3
/h in the compact
sound- and heat-insulated casing
with water heater
Series
VENTS MPA
Rated air flow, m
3
/h
800, 1200, 1800, 2500, 3200,
3500, 5000
Heater type Phase
E - electrical heating
elements;
W - water coils
1
single-phase;
3
three-phase
Designation key:
LCD control panel SAS908 control panel
Integrated control system
_
no control system
LCD
two rows;
3
three rows;
4
four rows
Designation key:
Integrated control system
_
no control system
LCD
up to 300 m
3
/h
page
44
VENTS VUT 300 mini EC Comfo
air handling units with heat recovery and EC motor
Air capacity
up to 300 m
3
/h
page
48
VENTS VUE 100 P mini / VUT 100 P mini air handling units
with heat recovery
Air capacity
up to 106 m
3
/h
VENTS VUE2 150 P EC COMFO
air handling units with heat recovery and EC motor
Air capacity
up to 170 m
3
/h
page
70
VENTS VUT 300 E2V EC
air handling units with heat recovery and EC motor
Air capacity
up to 300 m
3
/h
page
50
VENTS VUT 300 EV mini EC / VENTS VUT 301 EV mini EC
air handling units with heat recovery and EC motor
Air capacity
up to 270 m
3
/h
page
54
VENTS VUT 300 EVK mini EC / VENTS VUT 301 EVK mini EC
air handling units with heat recovery and EC motor
Air capacity
up to 270 m
3
/h
page
58
VENTS VUT2 200 P / VENTS VUE2 200 P / VENTS VUTE2 200 P
air handling units with heat recovery
Air capacity
up to 220 m
3
/h
page
62
VENTS VUT2 250 P EC / VENTS VUE2 250 P EC / VENTS VUTE2 250 P EC
air handling units with heat recovery and EC motor
Air capacity
up to 257 m
3
/h
page
66
VENTS. Air handling units | 06-2013
41
page
82
VENTS VUT H air handling units
with heat recovery
Air capacity
up to 2200 m
3
/h
page
86
VENTS VUT H EC
air handling units with heat recovery and EC motor
Air capacity
up to 600 m
3
/h
page
88
VENTS VUT EH and VENTS VUT WH
air handling units with heat recovery
Air capacity
up to 2200 m
3
/h
page
98
VENTS VUT EH EC and VENTS VUT WH EC
air handling units with heat recovery and EC motor
Air capacity
up to 600 m
3
/h
page
108
VENTS VUT PE EC and VENTS VUT PW EC
air handling units with heat recovery and EC motor
Air capacity
up to 4000 m
3
/h
page
116
VENTS VUT R EH and VENTS VUT R WH
air handling units with heat recovery and EC motor
Air capacity
up to 900 m
3
/h
VENTS VUT2 250 PU EC / VENTS VUE2 250 PU EC / VENTS VUTE2 250 PU EC
air handling units with heat recovery and EC motor
Air capacity
up to 275 m
3
/h
page
74
VENTS VUT 350 U EC / VENTS VUT 350 EU EC
air handling units with heat recovery and EC motor
Air capacity
up to 331 m
3
/h
page
78
VENTS VUT EH EC ECO
air handling units with heat recovery and EC motor
Air capacity
up to 450 m
3
/h
page
104
42
page 43 page 43
Series
VENTS VUT V mini
Series
VENTS VUT H mini
Description
Air handling units VUT (H) mini are the complete
ventilation units designed for air filtration, heating
and supply to the premises and removal of exhaust
air. The heat of the exhausted air is transferred to the
supply air through the plate heat exchanger. All the
models are compatible with 100 and 125 mm round
ducts.
Modifications
VUT V mini the models with vertical duct
connections, fans with AC motors.
VUT H mini the models with horizontal duct
connections, fans with AC motors.
Casing
The casing is made of aluzink with 20 mm mineral
wool internal heat and sound insulation.
Filter
Two G4 built-in filters ensure supply and exhaust air
fiiltration.
Fans
The unit is equipped with supply and exhaust
centrifugal fans with backward curved blades and
built-in thermal overheating protection with automatic
restart. The electric motors and the impellers are
dynamically balanced in two planes.
Heat exchanger
The plate heat exchanger is made of aluminium
plates. Whenever heat recovery is not required for
unit operation the heat exchanger block can be
easily replaced by a summer block. The unit is also
equipped with the drain pan for condensate drainage
as well as with built-in icing protecting system. During
operation of the heat exchanger in the winter time
the heat from the warm exhaust air is transferred
to the cold supply air. During extract air heat energy
extraction some condsensate can be generated.
If the temperature of the intake air is below -5
the condensate can get frozen. To prevent the heat
exchanger freezing electronic protection system
is applied. It switches the supply fan off as the
temperature sensor requires. Warm extract air
defrosts the heat exchanger, then the supply fan
switches on and the unit continues operating under
rated conditions.
Control
Switching the unit on and its capacity control is
performed with thyristor speed controller (RS-1-400)
which provides smooth motor speed control over the
range of 0-100%.
Mounting
Air handling unit is mounted on the floor and
suspended to the ceiling by means of a seat angle
with inserted vibration-damping element or attached
to a wall with brackets. The unit can be mounted
either in service spaces or in main premises above
the suspended ceiling, in the pocket or the unit can
be placed directly in the room. Mounting position
shall provide correct condensate drainage. Access for
maintenance and filter cleaning shall be reserved on
the side of the removable side panel on the left from
supply air side.
Air handling units with the air
capacity up to 300 m
3
/h in the
compact sound- and heat-insulated
casing with vertical duct connections
Air handling units with the air
capacity up to 300 m
3
/h in the
compact sound- and heat-insulated
casing with horizontal duct
connections
Series
VENTS VUT
Duct connection
V
vertical
H
horizontal
Rated air capacity
[m
3
/h]
200; 300
Type
mini
Designation key:
AIR HANDLING UNITS WITH HEAT RECOVERY
Speed controller RS-1-400 Speed controller RS-1-400
Accessories
43
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VENTS VUT mini VENTS VUT mini
VUT 200 H mini VUT 200 V mini VUT 300 H mini VUT 300 V mini
Voltage [V / 50 Hz] 1~ 230 1~ 230
Maximum fan power [W] 2pcs. 58 2pcs. x 58
Fan current [] 2pcs. 0.26 2pcs. 0.26
Total unit power [W] 116 116
Total unit current [] 0.52 0.52
Air capacity [m
3
/h] 200 300
RPM 2500 2500
Noise level at 3m [dBA] 24-45 28-47
Transported air [
left
R
right
Rated air capacity
[m
3
/h]
300
Motor type
EC synchronous electronically
commutated motor
Designation key:
page 45 page 45
Type
mini
Control
type
Comfo
with high performance and total speed controllable
range. High efficiency reaching 90% is the premium
advantage of the electronically-commutated motors.
Heat exchanger
Plate cross-flow heat exchanger made of aluminium.
The heat exchanger may be replaced with a
summer block when heat recovery is not required.
The drain pan under the heat exchanger block ensures
condensate removal.
Control and automation
The units are equipped with integrated automation
and a multifunctional control panel with LED
indication (P3/010 T).
The delivery set includes a signaling cable for
connection with the control panel.
The integrated freeze protection system is designed
to prevent the heat exchanger freezing at low
temperatures. In case of freezing danger indication
by the temperature sensor the supply fan is turned
off to let warm extract air flow pass by the heat
exchanger and warm it up. After freezing danger is
no longer actual, the supply fan is turned on and the
unit reverts to the standard operation mode.
Control panel functions:
Turning the unit on/off.
Ventilation mode selection: minimum, medium,
maximum.
Minimum mode (MIN) setup in the range of 13
pre-set speeds. The medium speed (NORMAL) is
automatically set 80 m
3
/h above the minimum speed,
but it does not exceed the maximum (MAX) speed.
Filter replacement indication.
Mounting
The unit is designed for mounting on the floor or
fixing to the wall with a bracket. Access for the unit
servicing and filter cleaning on the front swivel panel
side.
Accessories
45
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT 300 V mini EC Comfo VUT 300 H mini EC Comfo
Voltage [V / 50 Hz] 1~ 230
Total unit power [W] 167
Total unit current [A] 1.13
Max. air capacity [m
3
/h] 300
RPM [min
-1
] 3200
Sound pressure level at 3 m [dBA] 28-47
Transported air temperature [C] from -25 up to +60
Casing material polymer coated steel
Insulation 20 mm mineral wool
Filter*: extract G4 (order code of replaceable filter SF VUT 300 V (H) mini EC Comfo G4)
supply
G4 / F7(EU7) (order code of replaceable filter SF VUT 300 V (H) mini EC Comfo G4) /
SF VUT 300 V (H) mini EC Comfo F7)
Summer block* order code VL VUT 300 V (H) mini EC Comfo
Connected air duct diameter [mm] 125
Weight [kg] 23
Heat recovery efficiency up to 78%
Heat exchanger type cross-flow
Heat exchanger material aluminium
* option: replaceable filter, summer block
Technical data:
Unit overall dimensions:
VUT 300 V mini EC Comfo VUT 300 H mini EC Comfo
46
VENTS. Air handling units | 06-2013
HEAT RECOVERY AIR HANDLING UNITS
VUT 300 V (H) mini EC Comfo
0 10 20 30 40 50 60 70 80
0
50
100
150
200
250
300
350
400
450
500
550
600
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
MAX
NORMAL
MIN
SFP 1,6 W/L/s
1
2
3
4
5
6
7
8
9
10
12
11
13
14
0 10 20 30 40 50 60 70 80
50
55
60
65
70
75
80
0 40 80 120 160 200 240 280 320
0 10 20 30 40 50 60 70 80
0
20
40
60
80
100
120
140
160
180
0 40 80 120 160 200 240 280 320
MIN
NORMAL
MAX
1
2
3
4
5
6
7
8
9
10
12
11
13
14
SFP 1,2 W/L/s
SFP 1,0 W/L/s
SFP 1,4 W/L/s
SFP 0,8 W/L/s
VUT 300 V(H) mini EC Comfo
VUT 300 V(H) mini EC Comfo
VUT 300 V(H) mini EC Comfo
Air capacity [l/s]
Air capacity [l/s]
Air capacity [l/s]
Air capacity [m
3
/h]
Air capacity [m
3
/h]
Air capacity [m
3
/h]
S
t
a
t
i
c
p
r
e
s
s
u
r
e
,
P
[
P
a
]
T
o
t
a
l
f
a
n
p
o
w
e
r
[
W
]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
[
%
]
VUT 300 H mini EC Comfo
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 52 31 48 47 35 41 37 34 20
L
wA
to outlet dB(A) 59 39 54 58 53 47 45 37 26
L
wA
to environment dB(A) 34 9 24 31 29 17 16 2 0
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 53 30 50 48 37 41 39 32 20
L
wA
to outlet dB(A) 60 39 54 55 54 45 45 33 25
L
wA
to environment dB(A) 34 5 25 30 29 21 14 6 2
VUT 300 V mini EC Comfo
47
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Application example:
Air disc valve VENTS VUT 300 H mini
EC Comfo
Ventilation grille
Unit design:
VUT 300 V mini EC Comfo (right modification)
VUT 300 H mini EC Comfo (right modification)
supply filter supply filter
exhaust fan
heat
exchanger
extract filter heat
exchanger
extract filter control
unit
drain pan
supply fan
supply fan drain pan
drain pipe
exhaust fan
drain pipe
48
Series
VENTS VUE 100 P mini
VENTS VUT 100 P mini
Air handling units with heat recovery
in the compact sound- and
heat-insulated casing.
Air capacity up to 106 m
3
/h.
Heat recovery efficiency from
64 up to 76%.
AIR HANDLING UNITS WITH HEAT RECOVERY
Description
Compact air supply and exhaust ventilation unit VUE
100 P mini is a simple and effective energy-saving
solution ventilation of apartments, cottages, single-
family houses, workshops and trade premises.
The unit is a fully-featured ventilation unit that
provides air cleaning, fresh air supply to the premise
and removal of extract air from the premise. Extract
air thermal energy is transferred to the cross-flow
heat exchanger and is used to warm up the supply
air flow. Built-in heat exchanger prevents heat losses
and saves operating costs for heating in winter and
air conditioning in summer.
Due to the compact casing and silent operation the
VUE 100 P mini unit can be installed behind suspended
ceiling. The unit is designed for connection to 125
mm round air ducts. Several rooms may be ventilated
if they are connected with air distribution network.
Air flow regulation with P3-1-300 three speed switch.
Casing
The casing is made of corrosion-resistant alumozink
and sound-insulated with 15 mm ellular polyethylene
layer. For easy mounting the casing is fitted with
mounting brackets.
The detachable panel is swivel connected to the unit
to provide fast and easy access to the casing internal
components for servicing and maintenance. The unit
is equipped with two backdraft dampers, one in the
supply and the other in the exhaust air duct.
Filter
Supply and extract air flows are purified through two
filters with filtering class G4. The filters prevent dirt
and dust ingress into the room and protect the unit
components against contaminations.
Fans
The unit is equipped with reliable supply and exhaust
fans with forward curved blades that are powered by
Operating logic
vertical duct
connection
Motor type
EC synchronous
electronically commutated
motor
Series
VENTS VUT
Designation key:
Air handling units with heat recovery
for cold climate.
Air capacity up to 300 m
3
/h.
Heat recovery efficiency up to 95%
Heater type
and number
E2
P
[
P
a
]
Air capacity [m
3
/h]
Air capacity [m
3
/h]
VUT 300 E2V EC
0
50
100
150
200
250
Air capacity [l/s]
T
o
t
a
l
f
a
n
p
o
w
e
r
[
W
]
VUT 300 E2V EC
80
85
90
95
100
Air capacity [l/s]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
[
%
]
Air capacity [m
3
/h]
VUT 300 E2V EC
1
1
2
2
3
3
HEAT RECOVERY AIR HANDLING UNITS
Overall dimensions: Technical data:
53
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
exhaust fan with
EC motor
supply filter
electric heater for
air pre-heating
electric heater for air
warming up
extract filter
supply fan with
EC motor
heat exchanger
condensate drain pan
Unit design:
Application example:
Air disc valve
Ventilation grille
VENTS VUT 300 E2V EC
54
Description
The air handling units VUT 300/301 EV mini EC are
the fully-featured ventilation units with heat recovery
for air filtration, fresh air supply and stale air extract.
The heat contained in the extract air is recuperated in
the high-efficient plate counter-flow heat exchanger
to warm up supply air.
The units are designed for energy efficient ventilation
of cottages and flats and are compatible with round
125 mm air ducts.
Modifications
VUT 300 EV mini EC
vertical duct
connection
Type
mini
Motor type
EC
synchronous
electronically commutated
motor
Series
VENTS
VUT
Designation key:
Heater type
E
electric heater
55
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
panel for the VUT 301 EV mini EC model. Both
models are controllable from a remote controller
(optional accessory).
Control and protection functions:
Turning the unit on/off from the control panel.
Air supply to the electric heating elements during
the unit shutdown.
Three fans speeds are adjusted during the system
setup.
The heat exchanger downstream of the heat
exchanger warms up supply air flow up to the
comfortable temperature.
Input for alarm signal from the fire fighting
system.
The supply fan is turned off in case of freezing
danger for the period required for the heat
exchanger defrosting.
Relay input for connection of the CO
2
/ humidity
/ IAQ or any other sensor that switches the unit to
maximum speed.
Filter clogging control by motor hours.
Unit week schedule setting.
Controllable ventilation on demand:
The unit is equipped with a contact for relay
signal from an external sensor. The unit operation
according to an external sensor (for example, CO
2
sensor) enables energy demand reducing.
Operation logic of the unit with CO
2
sensor:
An unoccupied ventilated premise has low CO
2
concentration and requires no intensive ventilation.
The unit operates at low speed for minimum
permanent ventilation. As people come inside, CO
2
concentration in the premise increases and the
signal from CO
2
sensor closes relay contact.
The unit is turned to maximum speed until CO
2
concentration in the room drops down and the
contact is opened. After that the unit reverts to the
previous operation speed.
To arrange this operating logic it is required to
connect any sensor with relay output and to
connect it to the respective unit input. The sensor is
available upon separate order.
Mounting
The unit must be fixed to the wall with anchor bolts
in a position that enables condensate drainage.
While mounting the unit provide service access on
the front panel side.
To ensure the correct supply air warming up
function, install the duct temperature sensor in the
supply air duct (included in the delivery set) not
more than 1 m from the supply air duct end.
Extra accessories
CO2-1 or CO2-2 sensors are recommended for
arrangement of automatic control of air capacity
and extra energy saving.
VUT 300/301 EV mini EC
Speed 1 2 3
Voltage [V / 50 Hz] 1~230
Max. fan power [W] 16 94 187
Fan current [A] 0.1 0.6 1.1
Electric heater power [kW] 1.5
Electric heater current [A] 6.5
Total unit power [kW] 1.69
Total unit current [A] 7.6
Max. air capacity [m
3
/h] 40 190 270
RPM [min
-1
] 1280 2240 3200
Sound pressure level at 3 m [dBA] 28 39 42
Transported air temperature [C] from - 25 up to +60
Casing material Polymer coated steel
Insulation 15 mm ( foiled polypropylene foam)
Filter: extract / supply bag type G4 (order code SFK 300 EV/EVK mini EC and SFK 300 EV/EVK mini EC F7
Connected air duct diameter [mm] 125
Weight [kg] 37
Heat recovery efficiency up to 95 %
Heat exchanger type Counter-flow
Heat exchanger material Polystyrene
Technical data:
56
VENTS. Air handling units | 06-2013
HEAT RECOVERY AIR HANDLING UNITS
VENTS VUT 300/301 EV mini EC
Sound pressure level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 58 27 41 50 55 52 47 43 34
L
wA
to outlet dB(A) 64 30 46 56 60 58 53 48 42
L
wA
to environment dB(A) 53 27 38 46 50 42 41 36 18
0 10 20 30 40 50 60 70 80
0
100
200
300
400
500
600
0 50 100 150 200 250 300
Air capacity [l/s]
S
t
a
t
i
c
p
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity [m
3
/h]
VUT 300/301 EV mini EC
0 10 20 30 40 50 60 70 80
0
50
100
150
200
250
0 50 100 150 200 250 300
Air capacity [l/s]
T
o
t
a
l
f
a
n
p
o
w
e
r
[
W
]
Air capacity [m
3
/h]
VUT 300/301 EV mini EC
0 10 20 30 40 50 60 70 80
80
85
90
95
100
0 50 100 150 200 250 300
Air capacity [l/s]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
[
%
]
Air capacity [m
3
/h]
VUT 300/301 EV mini EC
1
1
2
2
3
3
Overall dimensions: Technical data:
57
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Unit design:
supply fan with
EC motor
extract filter
electric air heater
control unit
supply filter
exhaust fan with
EC motor
heat exchanger
condensate drain pan
Application example:
Air disc valve
Ventilation hood
VENTS VUT 300/301 EV
mini EC
58
Description
The air handling units VUT 300/301 EVK mini EC units
with heat recovery connected to the kitchen hood are
the ideal solution for energy-saving ventilation of the
flats and cottages. The units have two operation logics:
Heat recovery operation mode. When the kitchen
hood is turned off, air is extracted through the air
ductworks and transfers heat to supply air through
the heat exchanger.
Kitchen hood operation mode. When the kitchen
hood is turned on, air is extracted through the kitchen
hood and is exhausted directly through the exhaust
duct outside. Both operation modes provide balanced
ventilation in the room.
Compatible with round 125 mm air ducts.
Modifications
VUT 300 EVK mini EC
vertical duct
connection
Type
mini
Motor type
EC
synchronous
electronically
commutated motor
Modification
K
kitchen hood
Series
VENTS
VUT
Designation key:
Casing
Made of white high-quality polymer coated steel,
internally filled with 15 mm cellular polypropylene
heat- and sound-insulating layer.
Filter
Supply and extract air flows are purified through two
bag filters with filtering class G4. The kitchen hood is
equipped with a multi-layer aluminium fat filter. The
replaceable filter with filtering class F7 is optionally
available.
Fans
High-efficient electronically-commutated motors
with external motor and impeller with backward
curved blades.
Such motors are the most state-of-the-art energy-
saving solution.
EC motors are featured with high performance
and total speed controllable range. High efficiency
reaching 90% is the premium advantage of the
electronically-commutated motors.
Heat exchanger
Counter-flow polystyrene heat exchangers with high
heat recovery efficiency. The drain pan under the
heat exchanger block ensures condensate removal.
In case of freezing danger determined by the
temperature sensor the supply fan is turned off
for the period required for the heat exchanger
defrosting. The heat exchanger is easily removed for
cleaning. When the kitchen hood is turned on, extract
air is directed from it directly to the air duct, passing
by the heat exchanger.
Heater
The unit is equipped with an electric heater located
downstream of the heat exchanger to warm up supply
air um to set comfortable temperature up to +30 C.
The heating electric elements have active overheating
protection controlled by the temperature sensor in
the air duct and two overheating thermostats. The
first one is actuated at +50 C and has automatic
reset and the second one is actuated at +90 C and
has manual reset. Air supply to the electric heating
Heater type
E
electric heater
59
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Technical data
VUT 300/301 EVK mini EC
Speed 1 2 3
Unit supply voltage, 50 Hz [V] 1~230
Max. fan power [W] 16 94 187
Fan current [A] 0.1 0.6 1.1
Electric heater power [kW] 1.5
Electric heater current [A] 6.5
Total unit power [kW] 1.69
Total unit current [A] 7.6
Max. air capacity [m
3
/h] 40 190 270
RPM [min
-1
] 1280 2240 3200
Sound pressure level at 3 m [dBA] 28 39 42
Transported air temperature [C] from - 25 up to +60
Casing material polymer coated steel
Insulation 15 mm (polypropylene foam foil)
Filter: extract / supply bag type G4 (order code SFK 300 EV/EVK mini EC and SFK 300 EV/EVK mini EC F7
Connected air duct diameter [mm] 125
Weight [kg] 37
Heat recovery efficiency up to 95 %
Heat exchanger type Counter-flow
Heat exchanger material Polystyrene
elements at the end of the heating cycle ensures
cooling of the electric heating elements.
Control and automation
The unit has integrated automation with the
control from the multifunctional built-in control
panel for the VUT 300 EVK mini EC model or the
external control panel for the VUT 301 EVK mini EC
model. Both models are controllable from a remote
controller (optional accessory). The speed control
buttons for the kitchen hood mode are located on
the front panel of the kitchen hood.
Control and protection functions:
Turning the unit on/off from the control panel.
Air supply to the electric heating elements during
the unit shutdown.
Three fans speeds are adjusted during the system
setup.
The heat exchanger downstream of the heat
exchanger warms up supply air flow up to the
comfortable temperature.
Input for alarm signal from the fire fighting
system.
The supply fan is turned off in case of freezing
danger for the period required for the heat
exchanger defrosting.
Changeover between heat recovery and kitchen
hood operation modes.
Relay input for connection of the CO
2
/ humidity
/ IAQ or any other sensor that switches the unit to
maximum speed.
Filter clogging control by motor hours.
Unit week schedule setting.
Controllable ventilation on demand:
The unit is equipped with a contact for relay
signal from an external sensor. The unit operation
according to an external sensor (for example, CO
2
sensor) enables to reduce energy demand.
Operation logic of the unit with CO
2
sensor:
An unoccupied ventilated premise has low CO
2
concentration and requires no intensive ventilation.
The unit operates at low speed for minimum
permanent ventilation.
As people come inside, CO
2
concentration in the
premise increases and the signal from CO
2
sensor
closes relay contact.
The unit is turned to maximum speed until CO
2
concentration in the room drops down and the
contact is opened. After that the unit reverts to the
minimum speed.
To arrange this operating logic it is required to
connect any sensor with relay output and to
connect it to the respective unit input. The sensor is
available upon separate order.
Mounting
The unit must be fixed to the wall with anchor bolts
in a position that enables condensate drainage.
While mounting the unit provide service access on
the front panel side.
To ensure the correct supply air warming up
function, install the duct temperature sensor in the
supply air duct (included in the delivery set) not
more than 1 m from the supply air duct end.
Extra accessories
CO2-1 or CO2-2 sensors are recommended for
arrangement of automatic control of air capacity
and extra energy saving.
60
VENTS. Air handling units | 06-2013
HEAT RECOVERY AIR HANDLING UNITS
VENTS VUT 300/301 EVK mini EC
Sound pressure level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 58 27 41 50 55 52 47 43 34
L
wA
to outlet dB(A) 64 30 46 56 60 58 53 48 42
L
wA
to environment dB(A) 53 27 38 46 50 42 41 36 18
0 10 20 30 40 50 60 70 80
0
100
200
300
400
500
600
0 50 100 150 200 250 300
Air capacity [l/s]
S
t
a
t
i
c
p
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity [m
3
/h]
VUT 300/301 EVK mini EC
0 10 20 30 40 50 60 70 80
0
50
100
150
200
250
0 50 100 150 200 250 300
Air capacity [l/s]
T
o
t
a
l
f
a
n
p
o
w
e
r
[
W
]
Air capacity [m
3
/h]
VUT 300/301 EVK mini EC
0 10 20 30 40 50 60 70 80
80
85
90
95
100
0 50 100 150 200 250 300
Air capacity [l/s]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
[
%
]
Air capacity [m
3
/h]
VUT 300/301 EVK mini EC
1
2
3
1
2
3
Overall dimensions: Technical data:
61
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Unit design:
supply fan with EC motor
extract filter
electric heater
control unit
supply filter
exhaust fan with EC
motor
heat exchanger
condensate drain pan
bypass
Application example:
Air disc valve
Ventilation hood
VENTS VUT 300/301 EVK
mini EC
62
Description
The suspended air handling units VUT2, VUE2 and
VUTE2 200 P are the fully-featured ventilation units
that ensure air filtration, fresh air supply and stale air
extract.
The model VUT2 ensures sensible heat recovery and
the models VUE2 and VUTE2 ensure sensible heat and
moisture recovery in two plate heat exchangers.
The units are applied as components of ventilation
and air conditioning networks for various premises.
The units are featured with extremely low noise
level due to the fans located between two heat
exchangers.
High heat recovery efficiency of the units meets the
strict energy saving market demands. Compatible
with round 125 mm air ducts.
Modifications
VENTS VUT2 200 P
suspended
Number of heat
exchangers
2
Designation key:
Control panel SAS908
Series
VENTS VUT
VENTS VUE
VENTS VUTE
Accessories
63
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT2 200 P
VUE2 200 P
VUTE2 200 P
Ventilation mode LOW (low) MED (medium) HIGH (maximum)
Voltage [V / 50 Hz] 1 ~ 230
Max. fan power [W] 67 104 142
Fan current [A] 0.58 0.63 0.68
Max. air capacity [m
3
/h] 80 143 220
RPM [min
-1
] 1120 1890 2910
Sound pressure level at 3 m [dBA] 20 28 36
Max. transported air temperature [C] from - 25 C up to +40 C
Casing material aluzinc
Insulation 10 mm cellular polypropylene
Filter: extract / supply bag type G4 (order code SFK VUT2 200-250 P/P EC G4)
Connected air duct diameter [mm] 125
Heat recovery efficiency up to 89 %
Heat exchanger type cross-flow, 2 items
* maximum speed is activated by a signal from the control panel, humidity sensor, thermostat, CO
2
sensor, etc.
Technical data:
1
2
5
8
6
4
7
6
6
2
2
2
5
1
8
5
9
7
Overall dimensions: VENTS VUT2/VUE2/VUTE2 200 P
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
%
P
o
w
e
r
,
[
W
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
50
60
70
80
90
VUT2
VUE2
60
80
100
120
140
160
1
2
3
0 10 20 30 40 50 60
0
50
100
150
200
250
300
0 5 2 0 0 2 0 5 1 0 0 1 0 5 0
Air capacity, [l/s]
1 2 3
VUTE2
HIGH
MED
LOW
64
VENTS. Air handling units | 06-2013
exhaust fan
control unit
drain pan:
for the unit VUT2 200 P
2 items
for the unit VUE2 200 P
1 item
the unit VUE2 200 P has no drain pan
supply filter
extract filter
supply fan
Unit design:
HEAT RECOVERY AIR HANDLING UNITS
Application example:
Air disc valve
Ventilation hood
VENTS VU2 200 P
heat exchanger:
for VUT
plastic
for VUE
polymerized cellulose
for VUTE
polymerized cellulose
heat exchanger:
for VUT
plastic
for VUE
polymerized cellulose
for VUTE
plastic
65
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
66
Description
The suspended air handling units VUT2, VUE2 and
VUTE2 250 P EC are the fully-featured ventilation
units that ensure air filtration, fresh air supply and
stale air extract.
The model VUT2 ensures sensible heat recovery and
the models VUE2 and VUTE2 ensure sensible heat and
moisture recovery in two plate heat exchangers.
The units are applied as components of ventilation
and air conditioning networks for various premises.
The units are featured with extremely low noise level
due to the fans located between two heat exchangers
as well as EC motor technology.
High heat recovery efficiency of the units meets the
high energy saving market demands.
Modifications
VENTS VUT2 250 P EC
suspended
Motor type
EC
synchronous electronically
commutated motor
Number of heat
exchangers
2
Designation key:
Series
VENTS VUT
VENTS VUE
VENTS VUTE
67
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT2 250 P EC
VUE2 250 P EC
VUTE2 250 P EC
Voltage [V / 50 Hz] 1 ~ 230
Max. fan power [W] 125
Fan current [A] 0.87
Max. air capacity [m
3
/h] 257
RPM [min
-1
] 2930
Sound pressure level at 3 m [dBA] 39
Transported air temperature [C] from -25 C up to +40 C
Casing material aluzinc
Insulation 10 mm cellular polypropylene
Filter: extract / supply bag type G4 (order code SFK VUT2 200-250 P/P EC G4)
Connected air duct diameter [mm] 125
Heat recovery efficiency up to 89 %
Heat exchanger type cross-flow, 2 items
Technical data:
VENTS VUT/VUE/VUTE 2 250 P EC
0
100
200
300
400
0 5 2 0 0 2 0 5 1 0 0 1 0 5 0
Air capacity, [l/s]
8 7 6 5 1 2 3 4
20
40
60
80
100
120
P
o
w
e
r
,
[
W
]
8
5
6
7
4
2
3
1
50
60
70
80
90
VUT2
VUTE2
VUE2
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
%
Air capacity, [m
3
/h]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
1
2
5
8
6
4
7
6
6
2
2
0
5
1
8
5
8
1
Overall dimensions:
68
VENTS. Air handling units | 06-2013
HEAT RECOVERY AIR HANDLING UNITS
Application examples:
drain pan:
for the unit VUT2 250 P EC
2 items
for the unit VUTE2 250 P EC
1 item
the unit VUE2 250 P EC has no drain pan
Unit design:
exhaust fan with
EC motor
control unit
supply filter
extract filter
supply fan with
EC motor
heat exchanger:
for VUT
plastic
for VUE
polymerized cellulose
for VUTE
polymerized cellulose
heat exchanger:
for VUT
plastic
for VUE
polymerized cellulose
for VUTE
plastic
Air disc valve
Ventilation hood
VENTS VU 2 250 P EC
69
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
70
Description
The suspended air handling unit VUE2 150 P EC is
a fully-featured ventilation unit which ensures air
filtration, fresh air supply and stale air extract.
The thermal heat energy and latent moisture energy
contained in extract air are transferred to supply air in
two plate heat exchangers.
Suitable for integration into various ventilation and air
conditioning networks.
The unit is featured with extremely low noise level due
to the fans located between two heat exchangers as
well as EC motor technology.
Low energy demand and high heat recovery
efficiency of the units meet the strict energy saving
market demands.
Compatible with round 125 mm air ducts.
Casing
Made of aluzinc, internally filled with 10 mm cellular
polypropylene heat- and sound-insulating layer.
Filter
Supply and extract air flows are purified through two
bag filters with filtering class G4.
Fans
The unit is equipped with a supply and exhaust
centrifugal fan with backward curved blades and
integrated overheating protection thermostat with
automatic restart. The motors and the impellers are
dynamically balanced in two planes.
Heat exchangers
The enthalpy exchangers of polymerized cellulose
are designed to recuperate both sensible and latent
energy from extract air to warm up supply air. These
heat exchangers are frost-proof and produce no
condensate.
The units with polymerized cellulose heat exchangers
are recommended for use in air conditioned premises.
Control and automation
The unit includes integrated automation and a
multifunctional control panel (R3/010 T) with LED
indication.
The delivery set includes a signalling cable for
connection with the control panel.
The integrated freezing protection system is designed
to prevent the heat exchanger freezing at low
temperatures.
In case of freezing danger indication by the
temperature sensor the supply fan is turned off to
let warm extract air flow pass by the heat exchangers
and warm them up. After freezing danger is no
longer actual, the supply fan is turned on and the unit
reverts to the standard operation mode.
Control panel functions:
Turning unit on/off.
Ventilation mode selection: minimum, medium,
maximum.
Minimum mode setup in the range of 9 pre-set
speeds. The medium speed is automatically set
80 m
3
/h above the minimum speed, but it does
not exceed the maximum speed.
Filter replacement indication.
Mounting
The unit is designed for suspended ceiling mounting
in balcony, storeroom, basement, attic and other
auxiliary premises. The unit is also suitable for
installation in major premises directly to the ceiling,
behind the false ceiling or in the ceiling recess. Acess
for servicing and cleaning through the bottom panel.
Series
VENTS VUE2 150 P EC
COMFO
HEAT RECOVERY AIR HANDLING UNITS
Suspended air handling unit in heat-
and sound-insulated casing with
horizontal spigot orientation.
Air capacity up to 170 m
3
/h,
heat recovery efficiency
up to 87 %.
Rated air capacity
[m
3
/h]
150
Mounting
type
P
suspended
Control
type
COMFO
Motor type
synchronous
electronically
commutated motor
Service side
L
left
R
right
Number of heat
exchangers
2
Designation key:
Series
VENTS
VUE
71
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUE2 150 P EC COMFO
Voltage [V / 50 / 60 Hz] 1 ~ 230
Total unit power [W] 57
Total unit current [A] 0.55
Max. air capacity [m
3
/h] 170
RPM [min
-1
] 3730
Sound pressure level at 3 m [dBA] 45
Transported air temperature [C] from -25 C up to +40 C at air humidity not more than 80 %
Casing material aluzinc
Insulation 10 mm cellular polypropylene
Filter: extract / supply bag type G4 (order code SFK VUE2 150 P EC COMFO)
Connected air duct diameter [mm] 125
Weight [kg] 18
Heat recovery efficiency up to 87 %
Heat exchanger type cross-flow, 2 items
Heat exchanger material polymerized cellulose
Technical data:
518
125
7
6
6
581
2
2
3
Overall dimensions: VENTS VUE2 150 P EC COMFO
P
o
w
e
r
,
[
W
]
0
50
100
150
200
250
300
350
400
Air capacity, [l/s]
1 2 3 4 5 6 7 8 9 10
0
10
20
30
40
50
60
1
8
9
7
4
5
6
2
3
10
60
65
70
75
80
85
90
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
%
Air capacity, [m
3
/h]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
72
VENTS. Air handling units | 06-2013
Application examples:
HEAT RECOVERY AIR HANDLING UNITS
Unit design:
heat exchanger
heat exchanger
supply filter
exhaust fan with EC motor
control unit
RIGHT MODIFICATION LEFT MODIFICATION
control unit
supply fan with
EC motor
supply fan with
EC motor
extract filter extract filter
Air dics valve
Ventilation grille
VENTS VUE2 150 P EC
COMFO
73
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
74
Description
The suspended air handling units VUT2, VUE2 and
VUTE2 250 PU EC are the fully-featured ventilation
units that ensure air filtration, fresh air supply and
stale air extract.
The model VUT2 ensures sensible heat recovery and
the models VUE2 and VUTE2 ensure sensible heat and
moisture recovery in two plate heat exchangers.
The units are applied as components of ventilation
and air conditioning networks for various premises.
The units are featured with extremely low noise level
due to the fans located between two heat exchangers
as well as EC motor technology.
High heat recovery efficiency of the units meets the
strict energy saving market demands.
Compatible with round 125 mm air ducts.
Modifications
VENTS VUT2 250 PU EC
angle (versatile)
duct connection
Motor type
synchronous
electronically
commutated motor
Number of heat
exchangers
2
Designation key:
Series
VENTS VUT
VENTS VUE
VENTS VUTE
Mounting
type
P
suspended
75
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT2 250 PU EC
VUE2 250 PU EC
VUTE2 250 PU EC
Voltage [V / 50 Hz] 1 ~ 230
Max. fan power [W] 135
Fan current [A] 0.87
Max. air capacity [m
3
/h] 275
RPM [min
-1
] 2650
Sound pressure level at 3 m [dBA] 38
Max. transported air temperature [C] from -25 C up to +40 C
Casing material polymer coated steel
Insulation 20 mm mineral wool
Filter: extract / supply panel type G4
Connected air duct diameter [mm] 125
Heat recovery efficiency up to 90 %
Heat exchanger type cross-flow, 2 items
Technical data:
3
0
0
8
6
4
5
2
0
5
8
4
Overall dimensions: VENTS VUT2/VUE2/VUTE2 250 PU EC
60
70
80
90
VUT2
VUTE2
VUE2
0
100
200
300
400
0 0 3 0 5 2 0 0 2 0 5 1 0 0 1 0 5 0
Air capacity, [l/s]
1 3 2
20
40
60
80
100
120
140
1
2
3
Air capacity, [m
3
/h]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
P
o
w
e
r
,
[
W
]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
%
76
VENTS. Air handling units | 06-2013
HEAT RECOVERY AIR HANDLING UNITS
heat exchanger:
for VUT
aluminium
for VUE
polymerized cellulose
for VUTE
polymerized cellulose
heat exchanger:
for VUT
aluminium
for VUE
polymerized cellulose
for VUTE
aluminium
exhaust fan with
EC motor
extract filter
Ventilation grille
VENTS VU 250 PU EC
supply fan with
EC motor
control unit
extract filter
drain pipe:
for the unit VUT2 250 PU EC
2 items
for the unit VUTE2 250 PU EC
1 item
the unit VUE2 250 PU EC has no drain pipe
Unit design:
Ventila
VENTS VU 250 PU EC
Application examples:
drain pan:
for the unit VUT2 250 P EC
2 items
for the unit VUE2 250 P EC
1 item
the unit VUE2 250 P EC has no drain pan
Air disc valve
77
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
78
Description
The suspended air handling units VUT 350 ( E)U EC
are the fully-featured ventilation units that ensure air
filtration, fresh air supply and stale air extract.
The thermal heat contained in the extract air is
recuperated in the high-efficient plate counter-flow
heat exchanger to warm up supply air.
The electric heater in the unit is provided to warm up
supply air.
The units are applied as components of ventilation
and air conditioning networks for various premises.
The units are featured with extremely low noise level
due to EC motors and heat exchangers with high heat
recovery efficiency. Compatible with round 150 mm
air ducts.
Modifications
VUT 350 U EC
versatile duct
connection
Motor type
EC
electric heater
79
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT 350 U EC / VUT 350 EU EC
Speed 1 2 3
Voltage [V / 50 Hz] 1 ~ 230
Max. fan power [W] 36 138 220
Fan current [A] 0.29 0.97 1.48
*Electric heater power [kW] no / 2.0*
Total unit power [kW] 0.22 / 2.22*
Max. unit current [A] 1.5 / 10.2*
Max. air capacity [m
3
/h] 133 270 331
RPM [min
-1
] 1440 2200 2900
Sound pressure level at 3 m [dBA] 28 34 41
Transported air temperature [C] from - 25 up to +60
Casing material polymer coated steel
Insulation 20 mm mineral wool
Filter: extract / supply bag type G4
Connected air duct diameter [mm] 150
Weight [kg] 43 / 44*
Heat recovery efficiency 82 up to 98 %
Heat exchanger type Counter-flow
Heat exchanger material Polystyrene
* only for the VUT 350 EU EC unit
Technical data:
VENTS VUT 350 U EC
S
t
a
t
i
c
p
r
e
s
s
u
r
e
,
[
P
a
]
3 2 1
0
50
100
150
200
250
P
o
w
e
r
,
[
W
]
1
2
3
80
85
90
95
100
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
[
%
]
Air capacity, [m
3
/h]
Overall dimensions:
80
VENTS. Air handling units | 06-2013
drain pan with a drain pipe
counterflow heat
exchanger with bypass
electric heater
(VUT 350 EU EC)
exhaust fan with
EC motor
supply filter
supply fan with
EC motor
extract filter
control unit
Application example:
Air disc valve
Ventilation hood
VENTS VUT 350 EU EC
HEAT RECOVERY AIR HANDLING UNITS
Unit design:
81
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
82
page 82 page 82
Series
VENTS VUT H
Description
Air handling unit VUT H is a complete ventilation units
designed for air filtration and supply to the premises
and exhaust air removal. During the operation process
the extract air heat is transferred to the supply air
through the plate heat exchanger. All the models are
designed for connection with 125, 150, 160, 200,
250, 315 mm round ducts.
Casing
The casing is made of aluminium profile, double
skinned with 20 mm mineral wool heat-and sound-
insulating layer.
Filter
Two incorporated G4 panel filters for extract air
ventilation and F7 filters for supply air ventilation are
supplied with the unit.
Fans
The unit is equipped with supply and exhaust
centrifugal double-inlet fans with forward curved
blades and built-in thermal overheating protection
with automatic restart. The electric motors and
impellers are dynamically balanced in two planes. The
ball-bearings used with motors are designed for at
least 40 000 hours operation and are maintenance-
free.
Heat exchanger
The cross-flow air-to-air heat exchanger block is
manufactured from aluminum plates. Whenever heat
recovery is not required the heat exchanger block
can be easily replaced by a summer block. The unit
is also equipped with the drain pan for condensate
water drainage as well as built-in freezing protection
system. Its operating principle is based on switching
the supply fan off as the temperature sensor requires.
Warm extract air heats the heat exchanger. Then
the supply fan switches on and the unit continues
operating under rated conditions.
Control
The motor speed is controlled by means of 4-step
control switch by means of selecting the minimum,
average or maximum speed or the unit shutdown.
Mounting
Air handling unit is mounted on the floor and
suspended to the ceiling by means of a seat angle
with anti-vibration mounts or attached to a wall with
brackets. The unit can be mounted either in service
spaces or in main premises above the suspended
ceiling, in the pocket or can be placed directly in the
room. Mounting in any position shall provide correct
condensate drainage. Access for the fan maintenance
and filter cleaning shall be provided from outside of
the side panels.
Air handling units with the air
capacity up to 2200 m
3
/h and the
heat recovery efficiency up to 88%
in the compact sound- and
heat-insulated casing
Series
VENTS VUT
Duct connection
H
horizontal
Rated air capacity, m
3
/h
350; 500; 530; 600; 1000; 2000
Designation key:
AIR HANDLING UNITS WITH HEAT RECOVERY
Speed controller P3-1-300
Type G4 replaceable filter F7 replaceable filter Summer block
VUT 350 H
SF VUT 350-600 H G4 SF VUT 350-600 H F7
VL VUT 350 H
VUT 500 H VL VUT 500-600 H
VUT 530 H VL VUT 500-600 H
VUT 600 H VL VUT 500-600 H
VUT 1000 H SF VUT 1000 H G4 SF VUT 1000 H F7 VL VUT 1000 H
VUT 2000 H SF VUT 2000 H G4 SF VUT 2000 H F7 VL VUT 2000 H
Accessories to air handling units:
Accessories
83
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT 350 H VUT 500 H VUT 530 H
Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230
Maximum fan power [W] 2pcs. 130 2pcs. x 150 2pcs. x 150
Fan current [] 2pcs. 0.60 2pcs. 0.66 2pcs. 0.66
Total unit power [W] 260 300 300
Total unit current [] 1.2 1.32 1.32
Air capacity [m
3
/h] 350 500 530
RPM 1150 1100 1100
Noise level at 3m [dBA] 24-45 28-47 28-47
Transported air [
horizontal
Designation key:
Series
VENTS VUT EH
Series
VENTS VUT WH
AIR HANDLING UNITS WITH HEAT RECOVERY
Air handling units with the air
capacity up to 2100 m
3
/h and
heat recovery efficiency up to 78%
in sound-proof and heat-insulated
casing with water heater
Row number of the heater
2
two rows;
4
four rows
LCD control panel SAS908 control panel
Heat exchanger
The heat exchangers have high efficiency and are
manufactured from aluminium plates. The unit is also
equipped with the drain pan for condensate drainage.
Heater
The electric heater (for the unit VUT EH) or the water
heater (for the unit VUT WH) at outlet from the heat
exchanger is designed for warming up of supply
air up to the set level if heat recovery is not enough
to attain the set supply air temperature. The water
heaters are designed for max. operating pressure
1.0 MPa (10 bar) and max. heat medium operating
temperature 95 C.
Automation and control system
The unit incorporates an integrated automation and
control system with a multi-functional control panel
with LCD display. The standard delivery set includes
10 m connection cable for connection to the remote
control panel. The unit has the freezing protection
function to prevent the heat exchanger freezing
by means of actuating the bypass damper and
controlling water heater. As the temperature sensor
warns of the freezing danger, the bypass air damper
is opened and the intake air is directed through the
air duct beside the heat exchanger. As the heat
exchanger is warmed the supply air temperature rises
up to the set level while passing through the heater.
Meanwhile the warm extract air warms up the heat
exchanger. After the freezing danger is no longer
imminent, the bypass damper shuts the bypass duct
and the unit reverts to the standard operation mode.
VUT EH control and protection functions
control from the control panel: switching on/off,
speed selection, timer, faults;
maintaining the set room temperature by the sensor
on the control panel
water heater.
Accessories
89
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT EH
VUT WH
Unit overall dimensions:
Type Replaceable filter (panel filter) G4 Replaceable filter (panel filter) F7
VUT 350 EH
SF VUT 300-600 EH/WH G4 SF VUT 300-600 EH/WH F7
VUT 500 EH
VUT 530 EH
VUT 600 EH
VUT 800 EH
SF VUT 1000 EH/WH G4 SF VUT 1000 EH/WH F7
VUT 1000 EH
VUT 1500 EH
SF VUT 2000 EH/WH G4 SF VUT 2000 EH/WH F7
VUT 2000 EH
VUT 800 WH-2
SF VUT 1000 EH/WH G4 SF VUT 1000 EH/WH F7
VUT 800 WH-4
VUT 1000 WH-2
VUT 1000 WH-4
VUT 1500 WH-2
SF VUT 2000 EH/WH G4 SF VUT 2000 EH/WH F7
VUT 1500 WH-4
VUT 2000 WH-2
VUT 2000 WH-4
Accessories for air handling units:
activated at 50 C with automatic reset and another
thermostat activated at 90 C with manual reset.
Blowing of the heating elements for heat removing
at the end of the heating cycle;
filter clogging control by engine hours.
VUT WH control and protection functions
control from the control panel: switching on/
off, three-speed fan selection, selecting heating/
cooling modes (if connected to duct heater); room
temperature display;
maintaining supply air temperature set from the
control panel by controlling the circulation pump
and actuating the heat medium regulating valve;
input from the heat medium flow switch (pump
alarm);
safe start-up/ shutdown of the fans, warming
up of the water heater before start-up; return heat
medium temperature control when the fan is off;
freezing protection of the water heating coils by
the exhaust temperature sensor and the return heat
medium temperature sensor;
control of the compressor and condensing unit of
the water cooler by the room temperature sensor
(for the models equipped with a duct air cooler);
actuating the external air dampers with a return
spring;
unit operation according to daily and week
schedule (set at the system setup);
unit shut down at signal from the fire alarm
system;
smooth bypass damper control in the bypassing
mode to prevent the heat exchanger freezing.
Mounting
The unit is designed for indoor mounting. While
mounting the unit provide the correct condensate
collection and drainage. Access for the unit
servicing and filter cleaning is from the side panels
on the left from supply air side.
Options
For attenuation of sound generated by the fan it is
recommended to install the duct silencer (refer SR)
from inside before the unit. For vibration absorbing
it is recommended to install the flexible anti-
vibration connectors (refer VVG) on both sides of
the unit. The mixing units USWK are recommended
for smooth supply air temperature regulation in
the units equipped with water heaters. The mixing
unit USWK with three-way heat medium regulating
valve and circulation pump provides smooth heating
capacity regulation and minimizes the water heater
freezing danger.
Type
Dimensions, [mm]
D B B1 B2 B3 H H1 H2 H3 L L1 L2
VUT 350 EH
124 497 403 248 348 554 - 111 230 954 996 1054
VUT 500 EH
149 497 403 248 348 554 - 111 230 954 996 1054
VUT 530 EH
159 497 403 248 348 554 - 111 230 954 996 1054
VUT 600 EH
199 497 403 248 348 554 - 111 230 954 996 1054
VUT 800 EH
249 613 460 306 386 698 832 154 280 1071 1117 1171
VUT 800 WH
249 613 460 306 386 698 832 154 280 1071 1117 1171
VUT 1000 EH
249 613 460 306 386 698 832 154 280 1071 1117 1171
VUT 1000 WH
249 613 460 306 386 698 832 154 280 1071 1117 1171
VUT 1500 EH
314 842 581 320 520 814 947 201 595 1345 1388 1445
VUT 1500 WH
314 842 581 320 520 814 947 201 595 1345 1388 1445
VUT 2000 EH
314 842 581 320 520 814 947 201 595 1345 1388 1445
VUT 2000 WH
314 842 581 320 520 814 947 201 595 1345 1388 1445
90
VENTS. Air handling units | 06-2013
AIR HANDLING UNITS WITH HEAT RECOVERY
VUT 350 EH VUT 500 EH VUT 530 EH
Voltage [V / 50 Hz] 1~230 1~230 1~230
Maximum fan power [W] 2pcs. 130 2pcs. x 150 2pcs. x 150
Fan current [] 2pcs. 0.60 2pcs. 0.66 2pcs. 0.66
Electric heater power [kW] 3 3 4
Electric heater current [] 13 13 17.4
Number of water (glycol) coil rows - - -
Total unit power [kW] 3.26 3.3 4.3
Total unit current [] 14.2 14.32 18.72
Air capacity [m
3
/h] 350 500 530
RPM 1150 1100 1100
Noise level at 3m [dBA] 24-45 28-47 28-47
Transported air [
horizontal
Motor type
EC
synchronous electronically
commutated motor
Designation key:
AIR HANDLING UNITS WITH HEAT RECOVERY
LCD control panel SAS908 control panel
Heater type
E
electric heater;
W
water heater.
Accessories
99
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Heater
The electric heater (for the unit VUT EH) or the water
heater (for the unit VUT WH) at outlet from the heat
exchanger is designed for warming up of supply air up
to the set level if heat recovery is not enough to attain
the set supply air temperature. The water heaters are
designed for max. operating pressure 1.0 MPa (10 bar)
and max. heat medium operating temperature 95 C.
Control and automation
The unit incorporates an integrated automation
and control system with a multi-functional control
panel with LCD display. The standard delivery set
includes 10 m connection cable for connection to
the remote control panel. The unit has the freezing
protection function to prevent the heat exchanger
freezing by means of actuating the bypass damper
and controlling water heater. As the temperature
sensor warns of the freezing danger, the bypass
air damper is opened and the intake air is directed
through the air duct beside the heat exchanger.
As the heat exchanger is warmed the supply air
temperature rises up to the set level while passing
through the heater. Meanwhile the warm extract
air warms up the heat exchanger. After the freezing
danger is no longer imminent, the bypass damper
shuts the bypass duct and the unit reverts to the
standard operation mode.
VUT EH EC control and protection functions
control from the control panel: switching on/off,
speed selection, timer, faults;
maintaining the set room temperature by the
sensor on the control panel
smooth heating
capacity control;
three-speed fan speed control (low-medium-
high);
unit operation according to daily and week
schedule (timer adjustable from the control panel);
safe start-up/shutdown of the fans;
electric heater overheating protection by the
temperature sensor installed in the supply air
duct and by two overheating thermostats, one
thermostat activated at 50 C with automatic reset
and another thermostat activated at 90 C with
manual reset. Blowing of the heating elements for
heat removing at the end of the heating cycle;
filter clogging control by engine hours.
VUT WH EC control and protection functions
control from the control panel: switching the
unit on/off, room temperature display, fan speed
selection (low/medium/high speed);
each fan speed is 100% adjustable both for supply
and exhaust fan during the system setup;
maintaining supply air temperature set from the
control panel by controlling the circulation pump
and actuating the heat medium regulating valve;
freezing protection of the water heating coils by
the exhaust temperature sensor and the return heat
medium temperature sensor;
safe start-up/ shutdown of the fans, warming up
of the water heater before start-up; maintaining
the set return heat medium temperature when the
fan is off;
actuating the external air dampers with a return
spring;
unit shut down at signal from the fire alarm
system;
smooth bypass damper control in the bypassing
mode to prevent the heat exchanger freezing.
Mounting
The unit is designed for indoor mounting. While
mounting the unit provide the correct condensate
collection and drainage. Access for the unit
servicing and filter cleaning is from the side panels.
Accessories
For attenuation of sound generated by the fan it
is recommended to install the duct silencer (refer
SR) from inside before the unit. For vibration
absorbing it is recommended to install the flexible
anti-vibration connectors (refer VVG) on both sides
of the unit.
The VUT WH units are recommended to be
equipped with automatic air dampers for the water
heater freezing protection when the fans are off.
The mixing units USWK are recommended for
smooth supply air temperature regulation in the
units equipped with water heaters. The mixing unit
USWK with three-way heat medium regulating
valve and circulation pump provides smooth heating
capacity regulation and minimizes the water heater
freezing danger.
Type G4 replaceable filter (panel filter) F7 replaceable filter (panel filter)
VUT 300-1 EH EC
SF VUT 300-600 EH/WH G4 SF VUT 300-600 EH/WH F7
VUT 300-2 EH EC
VUT 400 EH EC
VUT 600 EH EC
VUT 300-1 WH EC
VUT 300-2 WH EC
VUT 400 WH EC
VUT 600 WH EC
Accessories for air handling units:
100
VENTS. Air handling units | 06-2013
AIR HANDLING UNITS WITH HEAT RECOVERY
VUT 300-1 EH EC VUT 300-2 EH EC VUT 300-1 WH EC VUT 300-2 WH EC
Voltage [V / 50 Hz] 1~ 230
Maximum fan power [W] 2pcs. 70
Fan current [] 2pcs. 0.60
Electric heater power [kW] 3.0 -
Electric heater current [] 13.0 -
Number of water (glycol) coil rows - 2
Total unit power [kW] 3.14 0.14
Total unit current [] 14.2 1.2
Air capacity [m
3
/h] 300
RPM 1380
Noise level at 3m [dBA] 24-45 24-45
Transported air [
C] -25 up to +60
Casing material aluzink
Insulation 25 mm mineral wool
Extract filter G4
intake F7 (EU7)
Connected air duct diameter [mm] 150 160 150 160
Weight [kg] 38 40
Heat recovery up to 90%
Heat exchanger type counter-flow
Heat exchanger material polystyrene
VUT 400 EH EC VUT 400 WH EC VUT 600 EH EC VUT 600 WH EC
Voltage [V / 50 Hz] 1~ 230 1~ 230
Maximum fan power [W] 2pcs. x 175 2pcs. x 175
Fan current [] 2pcs. 1.3 2pcs. 1.3
Electric heater power [kW] 4.0 - 4.0 -
Electric heater current [] 17.4 - 17.4 -
Number of water (glycol) coil rows - 2 - 2
Total unit power [kW] 4.35 0.35 4.35 0.35
Total unit current [] 20.0 2.6 20.0 2.6
Air capacity [m
3
/h] 400 600 550
RPM 1340 2150
Noise level at 3m [dBA] 28-47 28-47 28-47 28-47
Transported air [
horizontal
Motor type
synchronous electronically
commutated motor
Extra
designation
ECO
Series
VENTS
VUT
Designation key:
Electric heater Duct humidity sensor HV1
Heater
E
electric
Accessories
105
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Technical data:
B2
H
B3
B1
B
H
1
H
2
L
L
1
D
Type
Dimensions [mm]
D B B1 B2 B3 H H1 H2 L L1
VUT 300 EH EC ECO 159 566 125 391 186 475 202 118 1081 1187
VUT 400 EH EC ECO 199 687 255 588 220 514 235 139 1092 1174
VUT 900 EH EC ECO 249 940 250 837 345 620 262 156 1200 1282
Overall dimensions:
VUT 300 EH EC ECO VUT 400 EH EC ECO VUT 900 EH EC ECO
Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230
Unit max. power without heating [W] 138 306 340
Unit max. current without heating [A] 0.9 2 2.2
Optional electric heater power [kW] 3.0 3.0 3.0
Optional electric heater current [A] 13.0 13.0 13.0
Unit max. power with heating [kW] 3.14 3.31 3.34
Max. unit current with heating function [A] 13.9 15.0 15.2
Max. air capacity [m
3
/h] 300 450 942
RPM [min
-1
] 1380 2600 1740
Sound pressure level at 3 m [dBA] 24-45 28-47 28-47
Transported air temperature [C] from -25 up to +60 from -25 up to +60 from -25 up to +60
Casing material Aluzinc Aluzinc Aluzinc
Insulation 25 mm min.wool 25 mm min.wool 25 mm min.wool
Extract filter G4 G4 G4
Supply filter G4/F7(EU7) G4/F7(EU7) G4/F7(EU7)
Optional duct humidity sensor HV1 HV1 HV1
Connected air duct diameter [mm] 160 200 250
Weight [kg] 42 47 80
Heat recovery efficiency from 86 up to 98% from 85 up to 98% from 81 up to 98%
Heat exchanger type Counter-flow Counter-flow Counter-flow
Heat exchanger material Polystyrene Polystyrene Polystyrene
106
VENTS. Air handling units | 06-2013
HEAT RECOVERY AIR HANDLING UNITS
VENTS VUT EH EC ECO
Air capacity, [l/s]
S
t
a
t
i
c
p
r
e
s
s
u
r
e
,
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
%
VUT 400 EH EC ECO
0
100
200
300
400
500
600
700
800
0,8 W/l/s
1,0 W/l/s
1,2 W/l/s
LOW MED HIGH
1
2
3
4
6
7
8
5 9
10
11
12
VUT 400 EH EC ECO
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 54 32 50 51 40 43 40 37 25
L
wA
to outlet dB(A) 65 44 57 58 54 51 48 38 27
L
wA
to environment dB(A) 37 27 28 32 29 22 19 21 23
VENTS VUT EH EC ECO
S
t
a
t
i
c
p
r
e
s
s
u
r
e
,
[
P
a
]
Air capacity, [l/s]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
%
0
100
200
300
400
500
VUT 300 EH EC ECO
VUT 300 EH EC ECO
0,8 W/l/s
1,0 W/l/s
1,2 W/l/s
9
10
11
12
HIGH
LOW
MED
1
2
3
4
5
6
7
8
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 51 30 48 46 37 42 36 32 21
L
wA
to outlet dB(A) 60 41 54 57 55 44 46 35 24
L
wA
to environment dB(A) 33 23 23 32 27 19 15 19 18
point
Unit single power [W]
VUT 300
EH EC ECO
VUT 400
EH EC ECO
VUT 900
EH EC ECO
1 83 87 340
2 96 145 340
3 124 247 336
4 134 299 300
5 45 79 138
6 48 103 140
7 60 143 120
8 73 217 110
9 20 28 33
10 22 32 32
11 25 41 32
12 27 56 28
VENTS VUT EH EC ECO
0
100
200
300
400
500
600
700
0,8 W/l/s
1,0 W/l/s
1,2 W/l/s
1,4 W/l/s
1 5
7
8
9
10
11
12
2
3
4
6
1 5
7
8
9
10
11
12
2
3
4
6
LOW
MED
HIGH
VUT 900 EH EC ECO
VUT 900 EH EC ECO
Air capacity, [l/s]
S
t
a
t
i
c
p
r
e
s
s
u
r
e
,
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
%
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 57 36 55 51 41 47 42 38 28
L
wA
to outlet dB(A) 67 47 62 62 59 53 52 42 29
L
wA
to environment dB(A) 41 26 29 36 32 24 22 26 26
107
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Application examples:
Unit design:
supply filter
heat exchanger
bypass
condensate
drain pipe
exhaust fan
freeze protection
temperature sensor
duct humidity sensor RH
(accessory)
extract filter
duct temperature
sensor TES
control unit
supply fan
electric heater
drain pan
Air disc valve
Ventilation hood
VENTS VUT EH EC ECO
108
page 111 page 111
Series
VENTS VUT PE EC
Series
VENTS VUT PW EC
AIR HANDLING UNITS WITH HEAT RECOVERY
Description
Air handling unit VUT PE EC with the electric heater
and VUT PW EC with the water heating coils are the
complete ventilation units designed to provide both
both supply and exhaust ventilation with air filtration
and extract air removal. The exhaust air energy is used
to heat up the supply fresh air through the plate heat
exchanger.
Designed for ventilation and conditioning systems
for various premises requiring economic solution
and controllable air exchange. EC motors reduce
energy consumption by 1.5-3 times and ensure high
efficiency and low noise level at the same time. All the
models are compatible with 160 (150), 200, 250, 315
400 mm round ducts.
Modifications
VUT PE EC
electric heater;
W
water heater.
Motor type
EC
synchronous electronically
commutated motor
Designation key:
SAS908 control panel SAS908 control panel
Mounting
modification
P
suspended
Accessories
109
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
The standard delivery set includes 10 m connection
cable for connection to the remote control panel.
The unit has the freezing protection function to
prevent the heat exchanger freezing by means of
actuating the bypass damper and controlling water
heater. As the temperature sensor warns of the
freezing danger, the bypass air damper is opened
and the intake air is directed through the air duct
beside the heat exchanger. As the heat exchanger
is warmed the supply air temperature rises up to
the set level while passing through the heater.
Meanwhile the warm extract air warms up the heat
exchanger. After the freezing danger is no longer
imminent, the bypass damper shuts the bypass
duct and the unit reverts to the standard operation
mode.
VUT PE EC control and protection functions
control from the control panel: switching the
unit on/off, room temperature display, fan speed
selection (low/medium/high speed);
each fan speed is 100% adjustable both for supply
and exhaust fan during the system setup;
maintaining the set room temperature by the
sensor on the control panel smooth heating
capacity control;
safe start-up/shutdown of the fans;
electric heater overheating protection by the
temperature sensor installed in the supply air
duct and by two overheating thermostats, one
thermostat activated at 50 C with automatic reset
and another thermostat activated at 90 C with
manual reset. Blowing of the heating elements for
heat removing at the end of the heating cycle.
General description of VUT PW EC control
system
control from the control panel: switching the
unit on/off, room temperature display, fan speed
selection (low/medium/high speed);
each fan speed is 100% adjustable both for supply
and exhaust fan during the system setup;
maintaining supply air temperature set from the
control panel by controlling the circulation pump
and actuating the heat medium regulating valve;
freezing protection of the water heating coils by
the exhaust temperature sensor and the return heat
medium temperature sensor;
safe start-up/ shutdown of the fans, warming up
of the water heater before start-up; maintaining
the set return heat medium temperature when the
fan is off;
actuating the external air dampers with a return
spring;
unit shut down at signal from the fire alarm
system;
smooth bypass damper control in the bypassing
mode to prevent the heat exchanger freezing.
Mounting
The unit is designed for indoor mounting. While
mounting the unit ensure its correct position to
enable condensate collection and drainage. Access
for servicing and cleaning of the filter is from the
right or left side panel for the dimension types
350, 600 and 1000 and from the bottom for the
dimension types 2000 and 3000.
Accessories
For attenuation of sound generated by the fan it
is recommended to install the duct silencer (refer
SR) from inside before the unit. For vibration
absorbing it is recommended to install the flexible
anti-vibration connectors (refer VVG) on both sides
of the unit.
To disable uncontrollable air flow when the fans
are off and to prevent the water heater freezing
the units are recommended to be equipped with
automatic air dampers.
The mixing units USWK are recommended for
smooth supply air temperature regulation in the
units equipped with water heaters. The mixing unit
USWK with three-way heat medium regulating
valve and circulation pump provides smooth heating
capacity regulation and minimizes the water heater
freezing danger.
VENTS VUT 350 PE EC
Fig.1
VENTS VUT PE EC
VENTS VUT PW EC
Fig.2
Type
Dimensions, [mm]
Figure
D B B1 B2 B3 B4 H H1 L L1 L2
VUT 350 PE EC 160 485 415 596 132.5 220 285 130 1238 1286 948 1
VUT 600 PE EC 199 827 711 - 294 345 283 120 1238 1286 - 2
VUT 1000 PE EC 249 1350 1215 607.5 430 655 317 143 1346 1395 - 2
VUT 2000 PE EC 314 1050 915 457.5 247 575 750 375 1360 1408 - 2
VUT 3000 PE EC 399 1265 1130 565 297 632.5 830 415 1595 1643 - 2
VUT 600 PW EC 199 827 711 - 294 345 283 120 1238 1286 - 2
VUT 1000 PW EC 249 1350 1215 607.5 430 655 317 143 1346 1395 - 2
VUT 2000 PW EC 314 950 - 405 225 500 761 367 1400 1453 - 2
VUT 3000 PW EC 399 1265 - 563 347 570 881 427 1835 1888 - 2
Unit overall dimensions:
110
VENTS. Air handling units | 06-2013
AIR HANDLING UNITS WITH HEAT RECOVERY
VUT 350 PE EC VUT 600 PE EC VUT 600 PW EC
Voltage [V / 50 Hz] 1~ 230 1~ 230
Maximum fan power [W] 2pcs. 51 2pcs. 100
Fan current []
(EC motor voltage)
2pcs. 1.2 (48V) 2pcs. 2.4 (48V)
Electric heater power [kW] 1.5 4.0 -
Electric heater current [] 6,5 17.4 -
Number of water (glycol) coil rows - - 2
Total unit power [kW] 1.602 4.20 0.20
Total unit current [] 7.35 18.5 1.06
Air capacity [m
3
/h] 400 700 600
RPM 2950 3150
Noise level at 3m [dBA] 48 53
Transported air temperature [
C] -25 up to +50
Casing material aluzink
Insulation 25 mm mineral wool
Extract filter G4
Supply filter G4
Connected air duct diameter [mm] 400
Weight [kg] 290 295
Heat recovery efficiency up to 75%
Heat exchanger type cross-flow
Heat exchanger material aluminum
VENTS VUT PE EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 52 32 47 49 37 40 36 32 20
L
wA
to outlet dB(A) 62 39 56 58 55 48 44 36 25
L
wA
to environment dB(A) 33 20 21 31 29 21 17 20 22
Technical data:
Type
Replaceable filter
Intake (bag type) Extract (panel type)
VUT 350 PE EC SF 350 PE G4 SF 350 PE G4
VUT 600 PE EC SF 600 PE/PW G4 SF 600 PE/PW G4
VUT 1000 PE EC SF 1000 PE/PW G4 SF 1000 PE/PW G4
VUT 2000 PE EC SF 2000 PE/PW G4
VUT 3000 PE EC SF 3000 PE/PW G4
VUT 600 PW EC SF 600 PE/PW G4 SF 600 PE/PW G4
VUT 1000 PW EC SF 1000 PE/PW G4 SF 1000 PE/PW G4
VUT 2000 PW EC SF 2000 PE/PW G4
VUT 3000 PW EC SF 3000 PE/PW G4
Accessories to air handling units:
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
112
VENTS. Air handling units | 06-2013
AIR HANDLING UNITS WITH HEAT RECOVERY
VENTS VUT PW EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 67 68 67 67 66 59 61 61 56
L
wA
to outlet dB(A) 69 70 71 68 66 66 64 59 58
L
wA
to environment dB(A) 47 58 52 47 53 40 41 35 35
VENTS VUT PW EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 59 34 56 54 43 46 44 36 24
L
wA
to outlet dB(A) 68 43 59 62 59 52 52 40 29
L
wA
to environment dB(A) 38 29 27 39 33 23 23 24 24
VENTS VUT PE EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 68 67 68 70 68 60 60 61 55
L
wA
to outlet dB(A) 70 71 69 68 66 65 63 61 58
L
wA
to environment dB(A) 45 57 56 47 52 42 38 34 35
VENTS VUT PE EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 55 35 56 53 43 47 45 37 28
L
wA
to outlet dB(A) 65 47 60 61 61 52 51 40 30
L
wA
to environment dB(A) 39 30 30 39 33 23 24 26 28
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
113
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VENTS VUT PW EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 79 80 80 79 71 72 69 64 58
L
wA
to outlet dB(A) 81 84 83 79 71 77 71 73 69
L
wA
to environment dB(A) 56 66 66 59 55 48 44 38 38
VENTS VUT PE EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 77 83 83 78 72 73 66 67 58
L
wA
to outlet dB(A) 83 86 84 80 72 75 70 72 69
L
wA
to environment dB(A) 56 65 66 59 53 46 42 39 39
VENTS VUT PW EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 82 87 83 84 75 72 72 69 63
L
wA
to outlet dB(A) 84 86 85 82 74 80 77 76 73
L
wA
to environment dB(A) 60 69 68 62 56 51 47 41 41
VENTS VUT PE EC
Sound-power level Octave-frequency band [Hz]
Hz Tot. 63 125 250 500 1000 2000 4000 8000
L
wA
to inlet dB(A) 80 85 83 82 75 75 72 70 64
L
wA
to outlet dB(A) 86 87 86 83 77 80 75 75 74
L
wA
to environment dB(A) 61 70 69 63 58 51 48 42 41
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
114
VENTS. Air handling units | 06-2013
AIR HANDLING UNITS WITH HEAT RECOVERY
VENTS VUT PW EC
VENTS VUT PW EC
How to use water heater diagrams
System Parameters: Air flow = 400 m
3
/h. Outside air temperature =-20 C. Water temperature (in/out) = 70/50 C.
Supply air temperature. prolong the line of air flow (e.g., 400 m
3
/h) C up to the point where it crosses the outside air temperature (blue curve, e.g. -20 C); then draw a horizontal line C from this point
to the left till crossing water in/out temperature curve (e.g. 70/50 C). From this point draw a vertical line Cto the supply air temperature axis on top of the graphic (+23 C).
Heating coil capacity. Prolong the line C up to the point where it crosses the outside air temperature (e.g. -20 C, red curve) and draw a horizontal line C from this point to the right until it crosses water
in/out temperature curve (e.g., 70/50 C), from here draw a vertical line C up to the scale representing the heating coil capacity (6.6 kW).
Water flow. Prolong the line C down to water flow axis at the bottom of the graphic (0.105 l/s).
Water pressure drop. Draw the line C from the point where the line crosses the black curve to the pressure drop axis. (8.5 kPa).
Hot water coil parameters:
How to use water heater diagrams
Air Speed. Starting from 950 m
3
/h on the air flow scale draw a vertical line C till the air speed axis which makes about 3.35 m/s.
Supply air temperature. Prolong the line C up to the point where it crosses the outside air temperature (blue curve), e.g. -15 C; then draw a horizontal line C from this point to the left till crossing water
in/out temperature curve (90/70 C). From this point draw a vertical line C to the supply air temperature axis on top of the graphic (+23 ).
Heating coil capacity. Prolong the line C up to the point where it crosses the outside air temperature indicated as red curve (e.g., -15 ) and draw a horizontal line C from this point to the right to the
intersection of water in/out temperature curve (e.g., 90/70 ). From this point draw a vertical line C up to the scale of heating coil capacity (13.5 kW).
Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.14 l/s).
Water pressure drop. Draw the line C from the point where line crosses the black curve to the pressure drop axis. (1.5 kPa).
115
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VENTS VUT PW EC
How to use water heater diagrams
System Parameters: Air flow = 1450 m
3
/h. Outside air temperature =-25 C. Water temperature (in/out) = 70/50 C.
Air Speed. Starting from 1450 m
3
/h on the air flow scale draw a vertical line C till the air speed axis which makes about 3.2 m/s.
Supply air temperature. prolong the line C up to the point where it crosses the outside air temperature (blue curve, e.g. -25 C); then draw a horizontal line C from this point to the left till crossing
water in/out temperature curve (e.g. 70/50 C). From this point draw a vertical line Cto the supply air temperature axis on top of the graphic (+28 C).
Heating coil capacity. Prolong the line C up to the point where it crosses the outside air temperature (e.g. -25 C, red curve) and draw a horizontal line C from this point to the right until it crosses
water in/out temperature curve (e.g., 70/50 C), from here draw a vertical line C up to the scale representing the heating coil capacity (31.0 kW).
Water flow. Prolong the line C down to water flow axis at the bottom of the graphic (0.38 l/s).
Water pressure drop. Draw the line C from the point where the line crosses the black curve to the pressure drop axis. (9.8 kPa).
VENTS VUT PW EC
How to use water heater diagrams
System Parameters: Air flow = 3500 m
3
/h. Outside air temperature =-10C. Water temperature (in/out) = 90/70 C.
Air Speed. Starting from 3500 m
3
/h on the air flow scale draw a vertical line C till the air speed axis which makes about 4.65 m/s.
Supply air temperature. prolong the line C up to the point where it crosses the outside air temperature (blue curve, e.g. -10 C); then draw a horizontal line C from this point to the left till crossing water
in/out temperature curve (e.g. 90/70 C). From this point draw a vertical line Cto the supply air temperature axis on top of the graphic (+22,5 C).
Heating coil capacity. Prolong the line C up to the point where it crosses the outside air temperature (e.g. -10 C, red curve) and draw a horizontal line C from this point to the right until it crosses water
in/out temperature curve (e.g., 90/70 C), from here draw a vertical line C up to the scale representing the heating coil capacity (42.0 kW).
Water flow. Prolong the line C down to water flow axis at the bottom of the graphic (0.5 l/s).
Water pressure drop. Draw the line C from the point where the line crosses the black curve to the pressure drop axis. (6.5 kPa).
Hot water coil parameters:
116
AIR HANDLING UNITS WITH HEAT RECOVERY
Description
The air handling units VUT R EH with an integrated
electric heater or VUT R WH with an integrated
water heater are the ready-to-use ventilation units
that provide air filtering, supply of fresh air to the
premises and exhaust of stale extract air from the
premises with synchronous thermal energy transfer
from extract air flow to the supply air flow through
the rotary heat exchanger. The VUT R models are used
in ventilation and air conditioning systems installed
in various premises that require reasonable energy
saving solutions and controlled ventilation systems.
EC motors reduce energy demand by 1.5-3 times and
ensure high performance and low noise operation. All
the models are designed for connection to 160 and
250 mm round air ducts.
Modifications
VUT R EH - models with electric heater, fans with EC
motors, rotary heat exchanger.
VUT R WH - models with water (glycol) heater, fans
with EC motors, rotary heat exchanger.
Casing
The casing consists of a frame and three-layer 20
mm thick panels made of AlZn plate internally filled
with mineral cotton for reliable sound- and thermal
insulation.
Due to the specially designed removable side panels
the unit requires little space for servicing and
accessing to all the unit components.
Filter
G4/F7 supply and exhaust filters prevent dirt ingress
into the the room and are the essential components
that protect that unit elements against soiling.
Motor
The units are equipped with high-efficient direct
current electronically-commutated (EC) motors
with external rotor and backward curved impeller
blades. Such motor design is the most progressive
solution in energy saving. EC motors are featured
with high performance and well controllable speed
range. Premium efficiency reaching 90% is a definite
advantage of electronically commutated motors.
Rotary heat exchanger
The rotary heat exchanger is a rotating short cylinder
internally filled with corrugated aluminium band
placed in such a way as to ensure passing of the supply
and exhaust air streams through the heat exchanger
but to exclude their direct contact. While rotating of
the heat exchanger the band inside of it first comes in
contact with supply air stream and then with exhaust
air stream. Consequently the aluminium band is heated
up and cooled down by turns and recuperates the
thermal energy and moisture contained in the warm
extract air to cold intake air flow from outside. The
advantages of the rotary heat exchanger as compared
to the plate air-to-air heat exchangers include higher
efficiency, maintaining comfortable indoor humidity
Series
VENTS VUT R WH
Air handling units with heat recovery
with the air capacity up to 900 m
3
/h
in sound- and heat insulated casing
with integrated water heater.
Recuperating efficiency up to 85%.
Series
VENTS VUT R EH
Air handling units with the air
capacity up to 900 m
3
/h in sound-
and heat-insulated casing with
integrated electric heater.
Recuperating efficiency up to 85%.
SAS908 control panel SAS908 control panel
Series
VENTS VUT
Rated air capacity
[m
3
/h]
400; 700; 900
Energy
recovery unit
R
rotary heat
exchanger
Duct connection
H
horizontal
Designation key:
Motor type
EC synchronous electronically
commutated motor
Heater type
E
electric heater;
W
water heater
117
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Technical data:
level and extremely low freezing danger (it is nearly
zero for rated temperature and humidity conditions).
Heater
Electric heaters (VUT R EH EC models) or water
heaters (VUT R WH models) are used for application
of the air handling unit at low outdoor temperatures.
If heat recovery is not sufficient to reach the set
supply air temperature, the air heater is turned
automatically on and warms up the supply air flow.
The heaters are equipped with protecting devices
to ensure safe and reliable operation of the unit.
The water heaters are designed for max. operating
pressure 1.0 MPa (10 bar) and max. heat medium
operating temperature 95 C.
Control and automation
The unit is equipped with a built-in automation
system and a multi-functional control panel with a
graphic indicator. The standard delivery set includes
a 10 m cable for connection to the control panel.
VUT R EH EC automation functions:
turning the unit on and off according to set
parameters;
week-scheduled operation;
setting of the required supply air temperature
and air flow with an external control panel;
operation according to timer settings;
regulation of air control dampers;
filter clogging degree;
electric heating elements overheating
protection (operating and emergency thermostats);
RS485 interface.
VUT R WH EC automation functions:
turning the unit on and off according to set
parameters;
week-scheduled operation;
setting of the required supply air temperature
and air flow with an external control panel;
operation according to timer settings;
regulation of air control dampers;
filter clogging degree;
RS485 interface;
supply air temperature control by means of
actuating the three-way valve;
circulating pump control;
water (glycol) heater freezing protection
based on air temperature sensor after the heater
and on return medium thermostat.
Mounting
The air handling unit is suitable for mounting on a
level surface, to the ceiling or to wall with mounting
brackets. Service access is from the side panel on
the left (along supply air stream). In the unit VUTR
WH EC the water heater pipes are leaded outside to
the service side.
The air handling unit is suitable for mounting on a
level surface, to the ceiling or to wall with mounting
brackets. Service access is on side of service panels
of the side panel on the left (along supply air
stream). In the unit VUTR WH EC the water heater
pipes are leaded outside to the service side on the
left from supply air side.
VUT R
400 EH
VUT R
400 WH
VUT R
700 EH
VUT R
700 WH
VUT R
900 EH
VUT R
900 WH
Voltage [V / 50 Hz] 1~ 230 1~ 230 3~ 380 1~ 230
Max. fan power [W] 2 pcs. 95 2 pcs. 105 2 pcs. 135
Fan current [] 2 pcs. 0.46 2 pcs. 0.5 2 pcs. 0.65
Electric heater power [kW] 2.0 - 3.3 - 6.6 -
Electric heater current [] 8.7 - 15.0 - 10.7 -
Number of electric heating elements /
rows of water heating coils [pcs.]
1 2 1 2 2 2
Total unit power [W] 2295 290 3710 310 7040 440
Total unit current [] 10.9 2.1 17.3 2.2 14 3.2
Maximum air capacity [m
3
/h] 400 700 900
Rotation speed [min
-1
] up to 2700 up to 2600 up to 2600
Sound power level at 3 m [dBA] 45 52 58
Transported air temperature [
0
] -25+60 -25+60 -25+60
Casing material alumozink alumozink alumozink
Insulation 20 mm mineral wool 20 mm mineral wool 20 mm mineral wool
Extract filter G4 G4 G4
Supply filter G4 (F7) G4 (F7) G4 (F7)
Overall dimensions: Length [mm] 1166 1329 1329
Width [mm] 648 746 746
Height [mm] 670 702 702
Connected air duct diameter [mm] 160 250 250
Weight [kg] 112 128 130
Heat recovery efficiency [%] 85 85 85
Heat exchanger type rotary rotary rotary
Heat exchanger material aluminium aluminium aluminium
118
VENTS. Air handling units | 06-2013
Calculation of air temperature at heat exchanger outlet:
t = t
int
+k
eff
*(t
ext
- t
int
) / 100,
Where
t
int
- intake air temperature
0
,
t
ext
- extract air temperature
0
,
k
eff
- heat exchanger efficiency (as per diagram), %
AIR HANDLING UNITS WITH HEAT RECOVERY
VENTS VUT R EH (WH) VENTS VUT R EH (WH)
VENTS VUT R EH (WH)
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
P
r
e
s
s
u
r
e
,
P
[
P
a
]
Air capacity, [m
3
/h]
H
e
a
t
r
e
c
o
v
e
r
y
e
f
f
i
c
i
e
n
c
y
,
[
%
]
119
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
Calculation of water heater parameters
How to use water heater diagrams
Air Speed. Starting from 650 m
3
/h on the air flow scale draw a vertical line C till the air speed axis which makes about 2.35 m/s.
Supply air temperature. Prolong the line C up to the point where it crosses the outside air temperature (blue curve), e.g. +5 C; then draw a horizontal line C from this
point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line C to the supply air temperature axis on top of the graphic
(+26 ).
Heating coil capacity. Prolong the line C up to the point where it crosses the outside air temperature indicated as red curve (e.g., +5 ) and draw a horizontal line C
from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 ). From this point draw a vertical line C up to the scale of heating coil
capacity (5.8 kW).
Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.04 l/s).
Water pressure drop. Draw the line C from the point where line crosses the black curve to the pressure drop axis. (0.5 kPa).
Rotary heat exchanger operating logic
120
VENTS. Air handling units | 06-2013
VA
EXH EXT
EFN EF
*
EXT - extract side
EXH - exhaust side
EF* - extract filter (filter cartridge
is ordered separately)
EFN - fan
VUT mini (EC)
VUT H (EC)
VUE 100 P mini
OTD
EXH SPL
EXT
SF EF
SFN EFN
PHE
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
PHE - plate heat exchanger
VUT WH
OTD
EXH SPL
EXT
SF
EFN
EF
SFN WH
PHE
BP
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
WH - water heater
BP - bypass damper
PHE - plate heat exchanger
VUT WH EC
VUT 600-1000 PW EC
OTD
EXH SPL
EXT
SF
EFN
EF
SFN
PHE
BP
WH
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
WH - water heater
BP - bypass damper
PHE - plate heat exchanger
VUT H EC
SF EF
SFN
EFN
PHE
OTD
EXH SPL
EXT
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
PHE - plate heat exchanger
VPA
MPA E
PA E
SF SFN EH
OTD SPL
OTD - outside air
SPL - supply air
SF - supply filter
SFN - supply fan
EH - electric heater
MPA W
PA W
SF
OTD SPL
SFN WH
OTD - outside air
SPL - supply air
SF - supply filter
SFN - supply fan
WH - water heater
AHU SCHEMATIC DIAGRAMS
Suply extract units
Heat Recovery units with plate exchangers
121
WWW.VENTILATION-SYSTEM.COM
VENTS. Air handling units | 06-2013
VUT H
VUT 350-1000 PE EC
OTD
EXH SPL
EXT
SF
EFN
EF
SFN EH
PHE
BP
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
EH - electric heater
BP - bypass damper
PHE - plate heat exchanger
VUT R H
EXH
SPL
EXT
OTD
SF
RHE
EH
EF EFN
SFN
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
EH - electric heater
RHE - rotary heat exchanger
VUT R VH
OTD
EXT EXH
SPL
SF
RHE
WH
EF EFN
SFN
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
WH - water heater
RHE - rotary heat exchanger
VUT H
VUT 2000-3000 PE EC
VUT 2000-3000 PW EC
OTD
EXH SPL
EXT
SF
EFN
EF
SFN EH
PHE
BP
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
EH - electric heater
BP - bypass damper
PHE - plate heat exchanger
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
EH - electric heater
BP - bypass damper
PHE - plate heat exchanger
OTD - outside air
SPL - supply air
EXT - extract air
EXH - exhaust air
SF - supply filter
EF - extract filter
SFN - supply fan
EFN - extract fan
EH - electric heater
BP - bypass damper
PHE - plate heat exchanger
Heat recovery units with rotary heat exchangers
VENTS reserves the rights to modify any of its products features,
designs, components and specifications at any time and without notice
to maintain the development and quality of manufactured goods.