Technical Data: Sterile Tank System SRT140-6900/___

as aseptic buffer tank between a product treatment plant and one or several filling machines. Through the application of a sterile tank a return flow of the product to the processing plant is being avoided and thus it is excluded that the product is heated several times. This guarantees a continuously high product quality. The filling machines can be fed continuously for a long time so that they can be optimally utilized. At the same time the entire running time of the processing plant is being reduced and the energy consumption is reduced accordingly. GEA TDS sterile tanks are designed corresponding to the high requirements of aseptic systems and stand out due to their safety and long production intervals. Due to their pre-assembly in a favourable modular design the expense for installation and erection is minimized.

Design of the sterile tank system material: No. AISI 321 pressure - -1 bar / +3,5 bar, max. 140C range: execution : - standing on ball feet - double jacket for cooling, without pressure - manhole in tank lid - product inlet at tank bottom - approved to DGRL-AD2000

options:

- agitator installed in tank bottom - agitator installed laterally or on top - valve combination for connection to filling machine - valve combination for lateral filling - additional level probes for indication of full and empty tank - Process Control System - PC - single and double valve feed back - CIP - plant - air compressor

A B C D

E F G

Type net volume length sterile tank system width sterile tank system incl. pneumatic cabinet diameter tank min. tank height weight tank empty weight tank full depth switch cabinet width switch cabinet height switch cabinet

mm mm mm mm Kg Kg mm mm mm

050 5.000 2.650 3.100 1.900 4.000 1.600 7.000 500 1.100 2.600

100 10.000 2.650 3.600 2.400 4.600 2.500 13.000 500 1.100 2.600

150 15.000 2.650 3.600 2.400 5.800 3.500 19.000 500 1.100 2.600

200 20.000 2.800 3.700 2.500 6.700 3.900 25.000 500 1.100 2.600

250 25.000 2.800 3.700 2.500 7.800 5.100 31.000 500 1.100 2.600

300 30.000 2.800 3.900 2.700 8.000 7.000 38.000 500 1.100 2.600

_____________________________________________________________________________________
GEA TDS GmbH, Kruppstr. 3, 48683 Ahaus, Tel. (0 25 61) 8602 0, Fax (0 25 61) 8602 130
edition 10/08, subject to technical modifications

Energy data: Sterile Tank System SRT-140-6900/___


Type 1. steam saturated steam pressure min. 6 bar, max. 8 bar connected load kg/h consumption per sterilisation kg consumption during production kg/h 2. current voltage: 230/400 V frequency: 50 Hz connected load installed power agitator (option) 050 100 150 200 250 300

400 70 10

600 140 20

800 200 30

1.000 250 40

1.300 300 50

1.500 350 60

kW kW

2,5 1,1

2,5 1,5

2,5 2,2

2,5 2,2

2,5 3

2,5 4

3. cooling water inlet temperature max. 12C pressure: min. 2 bar, max. 4 bar connected load l/h consumption per sterilisation l consumption during production l/h 4. compressed air for sterile air feed pressure: min. 6 bar, max. 8 bar quality: dried free of oil and particles connected load Nm/h consumption per sterilisation 6 bar m consumption during production Nm/h 5. compressed air for valve control pressure min. 6 bar, max. 8 bar quality: dried free of oil and particles consumption (6 bar) Nm/h 6. connections product cleaning steam cooling water pressure air sterile air compressed air for valve control

5.000 1.500 -

7.000 1.800 -

8.000 2.200 -

10.000 2.600 -

12.000 3.000 -

15.000 3.500 -

100 15

200 300 400 500 30 50 70 85 depending on capacity of the filling machine

600 100

DN DN DN DN DN DN

25 50 25 25 25 8

40 50 25 25 25 8

40 50 40 25 40 8

50 50 40 40 40 8

50 65 50 40 50 8

65 65 50 40 50 8

_____________________________________________________________________________________