1. INTRODUCTION
Tuttnauer has developed a way in which an autoclave can be controlled by an external computer, as opposed to using the operation panel. It provides all the same details as the operation panel in regards to cycle names, numbers, stages and parameters. However it can also display the progress of a cycle in graphical or textual format to give a continuous, visual guide of how a process is progressing. It has the ability to store data so that previous cycles can be recalled. It also provides a visual display of all the piping so it can be monitored throughout the system, and the cycle stopped if there are any problems. The operator can control the autoclave either from the Touch Screen panel or from the remote PC, but he can not work from both of them the same time. This document describes how the operator works with the remote PC and the computer screens reaction to various keypads being pressed. The Touch Screen panel displays the same reactions when the same keys are pressed by the finger (instead the click of the mouse that presses them on the remote PC screen). Description of the screen has been minimized in order to define the minimum component and design requirements. Note: The Touch Screen is based on the 586-based Panel PC with 10.4 LCD flat panel display PPC-102. Please find attached with this manual the Panel PC Users Manual, which may be referred to at any time for further details regarding the Touch Screen.

GENERAL VIEW

REAR VIEW

TOUCH SCREEN

FRONT VIEW

ADMC
Autoclave Documentation Monitoring Control system

General
ADMC used: To gather information during a process from the Autoclave appliance. The software creates a History file of type *.mbd. This file can be opened by supporting software in the data base files, such as Access software by Microsoft. To control the autoclave. To display autoclave real time data. Gathering Information: Information about the process, such that when the appliance enters a process, it collects the startup information. This information is collected only once at the beginning of the process. All other information is collected at time intervals as defined by the user. Information at the Beginning of a Process: Cycle Parameters Ster Temp Ster Time Dry Time Pulse Number Exh. Mode End Temp. Hot Water Process Information: Time Run Time Temp1 Temp2 Press Stage Remark: The user may chose which data will be saved to the log. Process Parameters Start Time Start Date Cycle Number Error Code Prog. Name Description

Makeup of the History File


The History file that is created is of the type *.mbd. This file can be opened in any application that is supported by database files such as the application of Access by Microsoft. The file is created in a specific folder that is defined by the user. Remark: The displayed Data of the process must be Sorted by RunTime. File Name The name of the History file created supplies basic information about the file. e.g.: Lab1_Lab11999625_113917_2.mbd Where: Lab1=Name of the autoclave Lab = Autoclave type 1999=Year created 6=Month 25=Day 11=Hour 39=Minute 17=Second 2= Process number Basic Makeup The file is built up from 3 tables: Cycle Description
Ster Time Dry Time Puls Num Exh. Mode End Temp Process Description Start Time Start Date Cycle Num Error Code Prog. Name Description Process dTime Run Time Temp1 Temp2 Press Stage

Using the ADMC


Installation: Important: Please Remove the old ADMC software before the installation of the new version! Removing process: 1. Go to Control Panel, Add/Remove Programs. 2. Select ADMC from displayed List on Add/Remove Programs Window. 3. Operate Remove button and follow instructions. Enter the Drive where software installation is located. The Drive can be a CD or Floppy Disk. Press the SETUP.EXE icon. At this stage the SETUP software begins working. Messages/Requests must be traced, and then the software has completed installation. Installation software for locating the ADMC program is from the folder C:\Program files\ADMC as default. Operating the Application: Press the Start keypad in the Starting menu, after that press Program, and then ADMC.

Main Screen
Autoclave Status Window
Autoclave Name

Door status

Message window Autoclave status Selected Program

Reservoir status

Cycle Parameters Window

Main parameters of the selected cycle

Analog Inputs

Autoclave Analogs Inputs

Timers

When System on process, the timers window is showing the progress of the running process

Main screen Buttons


Start button
This button displayed when the system on standby. Pressing this button will start a new cycle.

Stop Button
This button displayed when the system is on process. Pressing this button will stop current cycle.

Clear Button
This button displayed when the process is finished. Pressing this button will bring the system to the standby mode

Cycle Button
This button displayed when the system on standby. Pressing this key will change the program. (Simulate the CYCLE key on appliance).

Events button
Pressing this button will display the events window

Log Button
Pressing this button will display the Log window.

Autoclaves Button
Pressing this button will display all active autoclaves.

Options Button
Pressing this button will display Options window.

Graphics Button
Pressing this button will display all active autoclaves on graphic mode.

Exit Button
Press this button to exit from application.

10

Graph control buttons


Pressing this button, the user can operate the graph. Available operations are: Lasso zoom, Move, Stretch.

When this button pressed, the graph will be displayed Automatically stretch to feet.

This button displayed when the graph display mode is Manual. Pressing this button allow stretch graph by moving X-Scale.

This button displayed when the graph display mode is Manual. Pressing this button allow move graph by moving X-Scale.

Pressing this button will print current graph.

11

Event Window

Usually, this window is empty. This window displays application errors.

Log Window
The application creates 2 types of logs: Process, Calibration. Pressing on LOG button will display Log Window:

The user can select which log will be displayed.

12

Select Process Log Select Process Log will display Process Log Window (History):

In this window the user can see all created Process Logs. Selecting one log from the list will display on right text box (Preview), sum General values of the selected log. Pressing O.K. button will display the selected log.

Process Log Window


When Log was selected, and pressed O.K. button, Process Log window will be displayed. The application can display the log on 2 modes: - Graphic. - Numeric.

13

Graphic mode display

Numeric mode display

14

Buttons on Process Log window


View Log remarks. Pressing this button will display Process Remarks window.

Pressing this button will change Log Display Mode from Graphic to Numeric.

Home Graph Button. Press this button to display all data on graph..

Press this button to stretch X-Scale of the graph.

Press this button to move X-Scale of the graph.

Press this button to display process data in Graph mode

15

Press this button to display History window, to select a new process log.

Press this button to display Print Log window.

Press this button to Exit from the Process Log Window.

16

User Remark Window


Pressing on View Remark button in process log window, will display User Remark window:

The application can add unlimited number of remarks to the same log. Select the row from remarks list to display remark in Remark text box. To edit current remark, change the text in a text box, and after that press Update button. To add new remark to the log, type new remark to the text box, and press Add New button. To delete current remark, press Delete button.

Print Process Log Window


Pressing on Print button in process log window, will display Print Process Log window:

17

From this window the user can select the printing mode of the log. Application can print in two different modes: - Graphic. - Numeric Select Graphic mode to print log as graph. If the parameter On Same Page will be selected, the application will print log descriptions and graph on same page. This option is useful if the process has short remarks. When Print Numeric is selected, the application will print the Table of the values as displayed on Numeric log display.

18

Calibration Log Window


If the selected log in Open Log window will be Calibration Log, then Calibration Log window will be displayed:

Select row from log list to display log. Remark button Pressing this button will open Calibration remark window. In this window, the user can add or edit remarks. Print Button Pressing this button will print selected calibration log.

19

Autoclaves window
Pressing on Autoclaves button in main window, will display Autoclaves window:

In this window, the user can select autoclave to display by double click on the wanted autoclave. (In the example shown only one autoclave was selected. The application can display maximum 8 autoclaves).

20

Graphics Window
Pressing on Graphics button in main window will show Graphics window:

In this window are displayed all active autoclaves in graph mode. (In example shown above only one autoclave was selected. The application can display maximum 8 autoclaves).

21

Options window
Pressing on Options button in main window will display Options window. In Options window, the user can see: - Autoclave Inputs - Autoclave Outputs - Autoclave Flags (Parameters) (Program Tab not available on vertical and table top autoclaves.) Inputs

This window displays analog inputs and digital inputs of the selected autoclave. From this window the user can calibrate analog inputs, by pressing Calibration button.

22

Outputs

This window displays all selected autoclave digital outputs. Flags

This window displays all flags (parameters) of the selected autoclave. From this window the user can change any parameter of the selected autoclave, by pressing Set Flag button.

23

Calibration window
Pressing on Calibration button in Inputs window, will display Calibration window:

From this window the user can calibrate selected autoclave analog inputs. Get Values button will upload GAIN & OFFSET from the autoclave. Set Values Button will download GAIN & OFFSET to the autoclave.

24

Set Flag window


Pressing on Set Flag button on Flags window, will display Set Flag window:

From this window the user can change any value of the selected flag (parameter). Pressing on Save button will download the new value to the control system of the autoclave.