You are on page 1of 24

TABLE OF CONTENT

1 3 2 - 4
2 1 5
3 1 6
4 1 7
5 3 8 - 10
6 1 11
7 1 12
8 1 13
9 1 14
10 1 15
11 1 16
12 1 17
13 1 18
14 1 19
15 1 20
16 1 21
17 1 22
18 2 23 - 24
Number
of pages
PAGE
T-RP902 : SIDE WALL (1) DESIGN CALCULATION
T-RP902 : SIDE WALL (1) STIFFENER LOCATION
T-RP902 : SIDE WALL (1) HORIZONTAL STIFFENER CALCULATION
T-RP902 : SIDE WALL (1) VERTICAL STIFFENER CALCULATION
T-RP902 : SIDE WALL (2) DESIGN CALCULATION
T-RP902 : SIDE WALL (2) STIFFENER LOCATION
T-RP902 : SIDE WALL (2) HORIZONTAL STIFFENER CALCULATION
T-RP902 : ROOF WALL STIFFENER CALCULATION
T-RP902 : ROOF WALL HORIZONTAL STIFFENER CALCULATION
T-RP902 : ROOF WALL VERTICAL STIFFENER CALCULATION
T-RP902 : SIDE WALL (2) VERTICAL STIFFENER CALCULATION
T-RP902 : BTM WALL DESIGN CALCULATION
T-RP902 : BTM WALL STIFFENER CALCULATION
T-RP902 : BTM WALL HORIZONTAL STIFFENER CALCULATION
T-RP902 : BTM WALL VERTICAL STIFFENER CALCULATION
T-RP902 : ROOF WALL DESIGN CALCULATION
APPENDIX
SECTIONAL STIFFENER PROPERTIES CALCULATION
TABLE OF ROARK FORMULA
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 1 of 24
SIDE WALL (1) DESIGN CALCULATION (Part 1)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Height, H 59 in 1500 mm
Tank Width, W 59.06 in 1500 mm
Tank Length, L 78.74 in 2000 mm
Design Pressure = FULL static head + 0.725 psig
Design Temp. = 80 Deg C
Material = A 240 316L
As per Table 11.4 Case No.1a
Rectangular plate, all edges simply supported, uniform over entire plate
g = 9.81
m/s
2
liq = 1000
kg/m
3
a = 19.69 in = 500 mm
b = 19.69 in = 500 mm
a/b = 1.0000
| = 0.2874 Loading q = liq

gH + 0.725 psi
o = 0.0444 = 9810
N/m
2
+ 0.725 psi
= 0.4200 = 1.422 psi + 0.725 psi
E = 2.83E+07 psi = 2.147 psi
t = 0.2362 in 6.0 mm
c.a = 0.0000 in 0 mm
t (corr) = 0.2362 in 6.0 mm
At Center,
Maximum Deflection, =
-(oqb
4
)/Et
3
t/2 = 0.118 in
= -0.04
y max (pt-1) = 0.04 in
Maximum Bending stress, o = (|qb
2
)/ t
2
o (pt1) = 4,286 psi
S
a
S
S
S
b
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 2 of 24
SIDE WALL (1) DESIGN CALCULATION (Part 2)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Height, H 59 in 1500 mm
Tank Width, W 59.06 in 1500 mm
Tank Length, L 78.74 in 2000 mm
Design Pressure = FULL static head + 0.725 psig
Design Temp. = 80 Deg C
Material = A 240 316L
As per Table 11.4 Case No.1d
Rectangular plate, all edges simply supported, with load increasing uniformly along length
g = 9.81
m/s
2
liq = 1000
kg/m
3
a = 19.69 in = 500 mm
b = 19.69 in = 500 mm
a/b = 1.0000
| = 0.1600 Loading q = ( liq

gH(max)+0.725 psi) - Q ( at Part-1 )
o = 0.0220 14715
N/m
2
= 2.859 psi - 2.147 psi
E = 2.83E+07 psi = 0.711 psi + 0.0000 psi
t = 0.2362 in 6.0 mm
c.a = 0.0000 in 0 mm
t (corr) = 0.2362 in 6.0 mm
At Center,
Maximum Deflection, =
-(oqb
4
)/Et
3
t/2 = 0.118 in
= -0.01
y max (pt-2) = 0.01 in
Maximum Bending stress, o = (|qb
2
)/ t
2
o (pt2) = 790 psi
S
a
S
S
S
b
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 3 of 24
SIDE WALL (1) DESIGN CALCULATION RESULTS
TANK NO. : T-RP902
PROJECT NO. EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Therefore , Consider worst condition of part 1 and part 2
At Center,
Maximum Deflection = y max (pt-1) + y max (pt-2)
= 0.04 + 0.01
= 0.04 in
where t/2 = 0.118 in
Since Sum of Max Deflection < t/2 : O.K
Max Bending stress, o = o (pt1) + o (pt2)
= 4,286 + 790
= 5,076 psi
Sum of Max Bending stress <
allowable
16,700 psi. : O.K
Material A 240 316L
Yield Stress, oy = 25000 psi
Stress Ratio, o/oy = 0.203
11.4 1(a)
Part1
11.41(d)
Part2
500
500
500
2.147psi
2.587psi
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 4 of 24
SIDE WALL (1) STIFFENER LOCATION
TANK NO. : T-RP902
PROJECT NO. EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 5 of 24
SIDE WALL (1) HORIZONTAL STIFFENER CALCULATION (minor stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Maximum bending moment occurs at the point where dM/dx = 0 and shear force is zero,
that is, at the middle of the beam.
L = 500.0 mm = 19.7 in
42.27 lb/in = 500.0 mm = 19.7 in
Load q = 2.1475 psi
unit load W = q x psi
where Wb = 42.27 lb/in
use FB 100 x 6
X
19.69 in
Bending Moment
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x = L/2 = 9.84 in
Maximum moment, M
max
=
WL
2
/ 8
= 2048 lb-in
Checking Section Modulus of Stiffener required
M/I = o/y
Hence, (I/y) required = M/y
= 2047.6
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.082
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 1,883 psi <
allowable
16700 psi. O.K
13.0 Mpa
Deflection
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x =L/2= 9.84 in

max
=
(5WL
4
)
384EI
= 0.001 < L/360 = 0.0547 in O.K
0.022 < L/360 = 1.389 mm
Therefore the size used is adequate.
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 6 of 24
SIDE WALL (1) VERTICAL STIFFENER CALCULATION (major stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
56.27 lb/in L = 1500.0 mm = 59.1 in
= 500.0 mm = 19.7 in
Load q = 2.8587 psi
unit load W = q x psi
= 56.3 lb/in
use FB 100 x 6
X
where a = 0 mm = 0.00 in
59.06 in where Wa = 0.725 lb/in (at 1 m)
where Wb = 56.3 lb/in (at 1.5 m)
Bending Moment
As per Table 8.1 Case 2d of Roark's (Uniformly increasing load)
Ra = 21.407 + 492.060
= 513.47 psi
Ma = -210.704 - 6457.483
= -6668.19 lb-in
Rb = 1683.02 - 513.468
= 1169.55 psi
Mb = 30322.89 + -6668.19 - 1264.22 - 32287.415
= -9896.93 lb-in
At x = l/2 = 29.53 in
Maximum moment, M
max
= Max of Ma and Mb
= 9897 lb-in ( L = 59.06 in )
Checking Section Modulus of Stiffener required
M/I = o/y
Hence, (I/y) required = M/y
= 9896.9
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.396
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 9,100 psi <
allowable
16700 psi. O.K
Deflection
As per Table 8.1 Case 2d of Roark's (Uniformly increasing load)
At x = 0.525L = 31.00 in
o
max
=
= 0.0095 < L/360 = 0.1640 in O.K
Therefore the size used is adequate.
0.001309 x WL
4
EI
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 7 of 24
SIDE WALL (2) DESIGN CALCULATION (Part 1)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Height, H 59 in 1500 mm
Tank Width, W 59.06 in 1500 mm
Tank Length, L 78.74 in 2000 mm
Design Pressure = FULL static head + 0.725 psig
Design Temp. = 80 Deg C
Material = A 240 316L
As per Table 11.4 Case No.1a
Rectangular plate, all edges simply supported, uniform over entire plate
g = 9.81
m/s
2
liq = 1000
kg/m
3
a = 29.53 in = 750 mm
b = 19.69 in = 500 mm
a/b = 1.5000
| = 0.4851 Loading q = liq

gH + 0.725 psi
o = 0.0838 = 9810
N/m
2
+ 0.725 psi
= 0.4845 = 1.422 psi + 0.725 psi
E = 2.83E+07 psi = 2.147 psi
t = 0.2362 in 6.0 mm
c.a = 0.0000 in 0 mm
t (corr) = 0.2362 in 6.0 mm
At Center,
Maximum Deflection, =
-(oqb
4
)/Et
3
t/2 = 0.118 in
= -0.07
y max (pt-1) = 0.07 in
Maximum Bending stress, o = (|qb
2
)/ t
2
o (pt1) = 7,234 psi
S
a
S
S
S
b
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 8 of 24
SIDE WALL (2) DESIGN CALCULATION (Part 2)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Height, H 59 in 1500 mm
Tank Width, W 59.06 in 1500 mm
Tank Length, L 78.74 in 2000 mm
Design Pressure = FULL static head + 0.725 psig
Design Temp. = 80 Deg C
Material = A 240 316L
As per Table 11.4 Case No.1e
Rectangular plate, all edges simply supported, with load increasing uniformly along width
g = 9.81
m/s
2
liq = 1000
kg/m
3
a = 29.53 in = 750 mm
b = 19.69 in = 500 mm
a/b = 1.5000
| = 0.2600 Loading q = ( liq

gH(max)+0.725 psi) - Q ( at Part-1 )
o = 0.0420 14715
N/m
2
= 2.859 psi - 2.147 psi
E = 2.83E+07 psi = 0.711 psi + 0.0000 psi
t = 0.2362 in 6.0 mm
c.a = 0.0000 in 0 mm
t (corr) = 0.2362 in 6.0 mm
At Center,
Maximum Deflection, =
-(oqb
4
)/Et
3
t/2 = 0.118 in
= -0.01
y max (pt-2) = 0.01 in
Maximum Bending stress, o = (|qb
2
)/ t
2
o (pt2) = 1,284 psi
S
a
S
S
S
b
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 9 of 24
SIDE WALL (2) DESIGN CALCULATION RESULTS
TANK NO. : T-RP902
PROJECT NO. EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Therefore , Consider worst condition of part 1 and part 2
At Center,
Maximum Deflection = y max (pt-1) + y max (pt-2)
= 0.07 + 0.01
= 0.08 in
where t/2 = 0.118 in
Since Sum of Max Deflection < t/2 : O.K
Max Bending stress, o = o (pt1) + o (pt2)
= 7,234 + 1,284
= 8,518 psi
Sum of Max Bending stress <
allowable
16,700 psi. : O.K
Material A 240 316L
Yield Stress, oy = 25000 psi
Stress Ratio, o/oy = 0.341
11.4 1(a)
Part1
11.41(e)
Part2
500
500
500
2.147psi
2.587psi
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 10 of 24
SIDE WALL (2) STIFFENER LOCATION
TANK NO. : T-RP902
PROJECT NO. EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 11 of 24
SIDE WALL (2) HORIZONTAL STIFFENER CALCULATION (minor stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Maximum bending moment occurs at the point where dM/dx = 0 and shear force is zero,
that is, at the middle of the beam.
L = 750.0 mm = 29.53 in
42.27 lb/in = 500.0 mm = 19.7 in
Load q = 2.147 psi
unit load W = q x psi
= 42.27 lb/in
use FB 100 x 6
X
29.53 in
Bending Moment
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x = L/2 = 14.76 in
Maximum moment, M
max
=
WL
2
/ 8
= 4607 lb-in
Checking Section Modulus of Stiffener required
M/I = o/y
Hence, (I/y) required = M/y
= 4607.1
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.184
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 4,236 psi <
allowable
16700 psi. O.K
Deflection
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x =L/2= 14.76 in

max
=
(5WL
4
)
384EI
= 0.004 < L/360 = 0.0820 in O.K
Therefore the size used is adequate.
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 12 of 24
SIDE WALL (2) VERTICAL STIFFENER CALCULATION (major stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
L = 1500.0 mm = 59.1 in
84.41 lb/in = 750.0 mm = 29.5 in
Load q = 2.859 psi
unit load W = q x psi
= 84.4 lb/in
use FB 100 x 6
X
where a = 0 mm = 0.00 in
59.06 in where Wa = 0.725 lb/in (at 1 m)
where Wb = 84.4 lb/in (at 1.5 m)
Bending Moment
As per Table 8.1 Case 2d of Roark's (Uniformly increasing load)
Ra = 21.407 + 741.301
= 762.71 psi
Ma = -210.704 - 9728.365
= -9939.07 lb-in
Rb = 2513.82 - 762.709
= 1751.11 psi
Mb = 45041.86 + -9939.07 - 1264.22 - 48641.826
= -14803.25 lb-in
At x = l/2 = 29.53 in
Maximum moment, M
max
= Max of Ma and Mb
= 14803 lb-in ( L = 59.06 in )
Checking Section Modulus of Stiffener required
M/I = o/y
Hence, (I/y) required = M/y
= 14803.3
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.592
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 13,611 psi <
allowable
16700 psi. O.K
Deflection
As per Table 8.1 Case 2d of Roark's (Uniformly increasing load)
At x = 0.525L = 31.00 in
o
max
=
= 0.0142 < L/360 = 0.1640 in O.K
Therefore the size used is adequate.
0.001309 x WL
4
EI
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 13 of 24
BOTTOM WALL DESIGN CALCULATION
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Height, H 59 in 1500 mm
Tank Width, W 59.06 in 1500 mm
Tank Length, L 78.74 in 2000 mm
Design Pressure = FULL static head + 0.725 psig
Design Temp. = 80 Deg C
Material = A 240 316L
As per Table 11.4 Case No.1a
Rectangular plate, all edges simply supported, uniform over entire plate
g = 9.81
m/s
2
liq = 1000
kg/m
3
a = 29.53 in = 750 mm
b = 19.69 in = 500 mm
a/b = 1.5000
0.4851 Loading q = liq

gH + 0.725 psi
0.0838 = 14715
N/m
2
+ 0.725 psi
0.4845 = 2.134 psi + 0.725 psi
2.83E+07 psi = 2.859 psi
t = 0.2362 in 6.0 mm
c.a = 0.0000 in 0 mm
t (corr) = 0.2362 in 6.0 mm
At Center,
Maximum Deflection, =
-(qb
4
)/Et
3
t/2 = 0.118 in
= -0.10
y max (pt-1) = 0.10 in
Maximum Bending stress, = (qb
2
)/ t
2
(pt1) = 9,630 psi
S
a
S
S
S
b
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 14 of 24
BOTTOM WALL STIFFENER LOCATION
TANK NO. : T-RP902
PROJECT NO. EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 15 of 24
BOTTOM WALL HORIZONTAL STIFFENER CALCULATION (minor stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Maximum bending moment occurs at the point where dM/dx = 0 and shear force is zero,
that is, at the middle of the beam.
L = 500.0 mm = 19.7 in
84.41 lb/in = 750.0 mm = 29.5 in
Load q = 2.8587 psi
unit load W = q x psi
where Wb = 84.41 lb/in
use FB 100 x 6
X
19.69 in
Bending Moment
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x = L/2 = 9.84 in
Maximum moment, M
max
=
WL
2
/ 8
= 4089 lb-in
Checking Section Modulus of Stiffener required
M/I = y
Hence, (I/y) required = M/y
= 4088.6
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.164
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 3,759 psi <
allowable
16700 psi. O.K
25.9 Mpa
Deflection
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x =L/2= 19.69 in

max
=
(5WL
4
)
384EI
= 0.002 < L/360 = 0.0547 in O.K
0.044 < L/360 = 1.389 mm
Therefore the size used is adequate.
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 16 of 24
BOTTOM WALL VERTICAL STIFFENER CALCULATION (major stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Maximum bending moment occurs at the point where dM/dx = 0 and shear force is zero,
that is, at the middle of the beam.
L = 1500.0 mm = 59.06 in
56.27 lb/in = 500.0 mm = 19.7 in
Load q = 2.859 psi
unit load W = q x psi
= 56.27 lb/in
use FB 100 x 6
X
where a = 0 mm = 0.00 in
59.06 in where Wa = 0.725 lb/in (at 1 m)
where Wb = 0.0 lb/in (at 1.5 m)
Bending Moment
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x = L/2 = 29.53 in
Maximum moment, M
max
=
WL
2
/ 8
= 24532 lb-in
Checking Section Modulus of Stiffener required
M/I = y
Hence, (I/y) required = M/y
= 24531.6
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.981
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 22,556 psi >
allowable
16700 psi. Not OK!!!
Deflection
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x =L/2= 29.53 in

max
=
(5WL
4
)
384EI
= 0.094 < L/360 = 0.1640 in O.K
Therefore the size used is adequate.
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 17 of 24
ROOF DESIGN CALCULATION
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Tank Height, H 59 in 1500 mm
Tank Width, W 59.06 in 1500 mm
Tank Length, L 78.74 in 2000 mm
Design Pressure = FULL static head + 0.725 psig Where Static head is not applicable = 0 psig
Design Temp. = 80 Deg C
Material = A 240 316L
As per API 650, 3.10.2.1 : All roofs and supporting structures shall be designed to support dead load
plus a uniform live load of not less than 1.2 kPa (25 lbf/ft2) of projected area.
Roof dead load = 1.79 kPa = 0.26 psi (Roof weight and external attachment )
Min Live load = 1.2 kPa = 0.17 psi
As per Table 11.4 Case No.1a Chapter 10 of Roark's
Rectangular plate, all edges simply supported, with uniform loads over entire plate.
g = 9.81
m/s
2
liq = 1000
kg/m
3
a = 29.53 in 750.0 mm
b = 19.69 in 500.0 mm
a/b = 1.5000 Loading q = MAX of (Live load + DeadLoad) or (Design Pressure)
0.4851 Loading q = (Live load + DeadLoad) or (Design Pressure)
0.0838 = 0.434 psi 0.87 psi
0.4845 Therefore, q = 0.870 psi
2.83E+07 psi 0.006 Mpa
t = 0.2362 in 6.0 mm
c.a = 0.0000 in 0 mm
t (corr) = 0.2362 in 6.0 mm
At Center,
Maximum Deflection, = -(qb
4
)/Et
3
t/2 = 0.118 in
= -0.03
= 0.029 in Max Deflection < t/2 ==> O.K
Maximum Bending stress, = (qb
2
)/ t
2
= 2,931 psi <
allowable
16,700 psi. then OK
Material A 240 316L
Yield Stress, y = 25000 psi
Stress Ratio, y = 0.117
At center of long side,
Maximum reaction force per unit length normal to the plate surface,
R = qb
= 8.30 lb/in
= 937.52 N/mm
S
a
S
S
S
b
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 18 of 24
ROOF DESIGN CALCULATION
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Weight Per pcs Qty Total
600NB Fabricated Blind = 95 1 95 kg
600NB Faricated Nozzle = 20 1 20 kg
600NB Fabricated Flg 59 1 59 kg
50NB Pipe = 1.5 4 6 kg
50NB WNRF = 2 4 8 kg
Piping & Accs = 5 1 5 kg
Stiffener (FB65 X 6) = 8.2 1 8.2 kg
Roof plate = 246.0 1 246.0 kg
Misc weight ( + Human )= 100 1 100 kg
Total Weight 547.2 kg
1206.4 lb
Total Loading (pressure) acting on the roof plate is calculated as shown below
Dead Load = Roof plate + Stiffener + Nozzle& Pipe = 547.2 kg
( Empty tank weight is not applicable for roof plate calc) F = m x g = 5368.0 N
Area = a x b = 3.00 m2
P = F/A = 1789 Pa
= 0.26 psi
Live Load, LL = 1200 Pa
= 0.17 psi
ROOF STIFFENER LOCATION
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 19 of 24
ROOF WALL HORIZONTAL STIFFENER CALCULATION (minor stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Maximum bending moment occurs at the point where dM/dx = 0 and shear force is zero,
that is, at the middle of the beam.
L = 500.0 mm = 19.69 in
25.69 lb/in = 750.0 mm = 29.5 in
Load q = 0.8700 psi
unit load W = q x psi
= 25.69 lb/in
use FB 100 x 6
X
19.69 in
Bending Moment
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x = L/2 = 9.84 in
Maximum moment, M
max
=
WL
2
/8
= 1244 lb-in
Checking Section Modulus of Stiffener required
M/I = y
Hence, (I/y) required = M/y
= 1244.312
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.050
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 1,144 psi <
allowable
16700 psi. O.K
Deflection
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x =L/2= 9.84 in

max
=
(5WL
4
)
384EI
= 5.38E-03 < L/360 = 0.0547 in O.K
Therefore the size used is adequate.
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 20 of 24
ROOF WALL VERTICAL STIFFENER CALCULATION (major stiffener)
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Maximum bending moment occurs at the point where dM/dx = 0 and shear force is zero,
that is, at the middle of the beam.
Where Static head is not applicable = 0 psig 1500.0 mm = 59.06 in
17.13 lb/in = 500.0 mm = 19.7 in
Load q = 0.8700 psi
unit load W = q x psi
= 17.13 lb/in
use FB 100 x 6
X
59.06 in
Bending Moment
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x = L/2 = 29.53 in
Maximum moment, M
max
=
WL
2
/8
= 7466 lb-in
Checking Section Modulus of Stiffener required
M/I = y
Hence, (I/y) required = M/y
= 7465.874
25000
Allowable Section Modulus of Stiffener required
Z = (I/y) required = 0.299
in
3
Using FB 100 x 6
I/y (stiffener) = 1.088
in
3
> (I/y) required O.K
Therefore, Max bending stress
max
= M
max
/ Z
stiffener
max = 2,240 psi <
allowable
16700 psi. O.K
Deflection
As per Table 8.1 Case 2e of Roark's (Uniform load on entire span)
At x =L/2= 29.53 in

max
=
(5WL
4
)
384EI
= 0.03 < L/360 = 0.16 in O.K
Therefore the size used is adequate.
Wb Wa
L
W
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 21 of 24
TABLE OF ROARK FORMULA
ITEM : T-RP902
PROJ ECT NO. EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Table 11.4 Case No.1a of Roark's
Table 11.4 Case No.1d of Roark's
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 22 of 24
TABLE OF ROARK FORMULA
ITEM : T-RP902
PROJ ECT NO. EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Table 8.1 Case 2d & 2e of Roark's
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 23 of 24
SECTIONAL STIFFENER PROPERTIES CALCULATION
TANK NO. : T-RP902
PROJECT : EPCIC OF JDA GAS BALANCING EVACUATION (EVA)
Stiffener Size FB 100 x 6
Material, A 240 316L
Yield Stress,
y
25000 psi
Allowable Stress,
allowable
16700 psi
Where :
d1 = 6 mm
d2 = 100 mm
b1 = 111 mm *
b2 = 6 mm
PART area (a) y a x y h
h
2
a x h
2
bd
3
/12
mm
2
mm
mm
3
mm
mm
2
mm
4
mm
4
1 663.89 3 1991.664 25.16 633.0487 420273.38 1991.664
2 600 56.00 33600 27.84 775.04 465024.01 500000
TOTAL 1263.888 35591.66 885297.4 501991.7
Therefore,
y = Ay = 35592 = 28.16
A 1263.888
C = 100 + 6 - 28.16
C = 77.84 mm
I = 1387289.1
mm
4
= 3.333
in
4
Z (I/C) = 17822.4209
mm
3
= 1.088
in
3
Effective plate length to act as stiffener
b1 =
b1 = 111 mm take min. L = 1500 mm, so R:
R = 750 mm
1
1
2
h1
b2
b1
h2
y2
C
d1
d2
y1
Plate
Stiffener
ts R tr * 56 . 1
Tank Design_Calc_(EVA)_REV3
04/01/2014 Page 24 of 24

You might also like