BRITISH MANUFACTURER
ENERGY EFFICIENCY
CONTROLS
SERVICE
TRAINING
www.airedale.com
01
Quick reference
Five product ranges supported by an extensive number of models and exceptional conguration exibility means that when selecting an Airedale system, your choice of variants is considerable, enabling you to precisely match your application. We apply the latest technology led by smart control logic to ensure our products offer you the highest efciency, resilience and quality. First and foremost, they are designed to be stand-alone, but when
6kW
200kW
DX
DX CW
INVERTER
D U A L
C O O L
FREE COOL
EC
PAGE 03
EasiCool 6 - 60kW
HFC R410A
HFC R407C
DX
AIR
DX CW
WATER
EC
PAGE 03
AlphaCool 8 - 101kW
HFC R407C
DX CW
AIR
FREE COOL
PAGE 04
IT Cooling
OnRak 3 - 33kW
CW
EC
2kW
60kW
PAGE 05
InRak 10 - 60kW
HFC R410A
DX CW
AIR
EC
EC
PAGE 05
SYSTEM SPECIFIC
PAGE 06
Global company
Airedale is a world leader in the design and manufacture of innovative, high efciency cooling solutions. We manufacture in three continents and export to customers in over fty countries through a network of more than seventy business partners.
Comfort
StoreMaster 50 - 77kW
HFC R410A
2kW
77kW
DX
AIR
FREE
HEAT PUMP
EC
PAGE 07
COOL
Cassette 2 - 11kW
CW
PAGE 07
*See product pages 3 - 14 inclusive for a reference to which icons represent standard or optional features
02
Chillers
SCROLL
6kW
1300kW
DX
AIR
PAGE 09
PAGE 11
PAGE 12
PAGE 10
COOL
EC
PAGE 11
CONTROLS
CENTRIFUGAL
PAGE 09
Service
24/7 support
PAGE 18
SCREW
PAGE 10
Flexible ChillerGuard/SafeCool service and maintenance plans; F Gas compliance On call engineers for immediate response AsNew energy upgrades Flat pack solutions/unit refurbishment
3kW
450kW
EC
DIGITAL
PAGE 13
Air Cooled Condensers & Dry Coolers CR 12 - 165kW (R410A) C/CS 11 - 105kW (R407C) DR 10 - 100kW
HFC R410A
HFC R407C
EC
PAGE 13
SERVICE
PAGE 14
Training
PAGE 14
PAGE 18
HEAT PUMP
PRODUCT KEY*
HFC R410A
HFC R410A
HFC R134a
HFC R134a
HFC R407C
HFC R407C
DX
AIR COOLED
EC
AIR
DX
WATER COOLED
INVERTER
WATER
CW
CHILLED WATER
HEAT PUMP
HEAT PUMP
UPFLOW
DOWNFLOW
UPFLOW/ DOWNFLOW
DIGITAL
MICRO
MICROCHANNEL COIL
D U A L
C O O L
FREE COOL
FREE-COOLING
EC
EC FAN
TRAINING
SCROLL COMPRESSOR
SCREW COMPRESSOR
CENTRIFUGAL COMPRESSOR
EC INVERTER COMPRESSOR
INVERTER COMPRESSOR
DIGITAL COMPRESSOR
DUAL COOL
03
SmartCool 20 - 200kW
HFC R410A
EasiCool 6 - 60kW
HFC R410A
KEY SPECIFICATIONS:
DX DX
WATER
AIR
DX DX
WATER
AIR
CW
CW
+ Automatic adjustment of air volume: Faced with system resistance, fan speed modulates to give constant air volume + High efciency de-humidication + Electronic expansion valves for up to 30% increase in system efciency
D U A L C O O L
+ Hot gas re-heat efciently re-heats cool air during dehumidication + Electric heating can be upgraded with thyristor control + Direct drive backward curved EC fan upgrade for all indoor and outdoor units
OPTIONS
+ Thyristor-controlled electric heating for precise control + Suction throttle valve technology for variable capacity + Dual power supply for redundancy and exibility + Optimised for EC fan
HFC R407C
FREE COOL
EC
INVERTER
EC
04
AlphaCool 8 - 101kW
HFC R407C
Continued operation of our clients IT infrastructure and ensuring availability of their data is paramount. Airedale provides us with a fully integrated cooling solution designed for maximum efciency and critical redundancy. Airedales latest chilled water and DX cooling technologies enable us to achieve our PUE target of less than 1.3.
Rob Garbutt, CEO, LDeX
KEY SPECIFICATIONS:
DX
AIR
CW
FREE COOL
CONTROLS
SERVICE
TRAINING
05
IT Cooling
OnRak 3 - 33kW
CW
EC
InRak 10 - 60kW
HFC R410A
EER up to 90.34
n + 1, CW
KEY SPECIFICATIONS:
KEY SPECIFICATIONS:
DX
AIR
CW
EC
EC
06
Our HPC facility is growing and without the use of the OnRak rear door heat exchangers it would not be possible to go to such high densities. The OnRak has saved us space in an already densely packed environment. It has also given us the exibility to t rear door heat exchangers to legacy or new cabinets from any manufacturer.
Dr Jon Summers, Senior Lecturer, The University of Leeds
KEY SPECIFICATIONS:
CONTROLS
SERVICE
TRAINING
07
Comfort
StoreMaster 50 - 77kW
HFC R410A
DX DX
AIR WATER E
Cassette 2 - 11kW
CW
Smaller models t the space of a standard ceiling tile
measuring 600mm2
+ 11 models for exibility in heating, cooling and air ow + Available in 2 pipe and 4 pipe congurations + Efcient AC backward curved fan technology + Low sound + Neat, compact design + Smart, unobtrusive + Fresh air connection
OPTIONS INCLUDE
KEY SPECIFICATIONS:
KEY SPECIFICATIONS:
HEAT PUMP
+ Cooling and heat pump variants + 57 - 75kW heating capacity with reverse cycle (dual circuit heat pump variant only) + Packaged or split modules (evaporator / condenser) + Tandem scroll compressors on a single circuit for improved efciency at part load (cooling-only version)
FREE COOL
EC
+ Heating based on a LPHW heating coil + Electric heating (two pipe variant only)
08
Our priority at the Harrogate Hydro leisure facility is to provide the comfortable environment which our customers have come to expect. A major concern was to nd a reliable, appropriate air conditioning system which would keep a cool, constant temperature within the building. Airedales chilled water chiller and cassette solution is delivering that.
Andy McCulloch, Group Engineer, Harrogate Borough Council
Ofces Shopping malls Retail outlets Leisure environments Commercial applications Distribution centres
CONTROLS
SERVICE
TRAINING
09
Chillers
Scroll
Centrifugal
DeltaChill (DCC) 110 - 960kW TurboChill (TTC) 200 - 1100kW DeltaChill FreeCool (DCF) 140 - 1030kW TurboChill FreeCool (TCF) 200 - 950kW
HFC R410A
ESEER up to 4.79
with EC fan option
HFC R134a
ESEER up to 5.69
with TTC, due to excellent part load efciencies
KEY SPECIFICATIONS:
DX
AIR
+ ETL listed* (selected models TTC) + Up to two compressors across a single circuit for reduced energy consumption at part load (TTC); dual circuit models for resilience (TTC, TCF) + Oil-free compressor enhances heat exchange + 25 - 100% variable speed control for exact capacity match + In-built compressor low current start (2A) + Low sound: Quiet or Extra Quiet + Interactive head pressure setpoint management + Flooded evaporator for optimum system efciency + Large surface area condenser coils + Economiser circuit provides increased cooling and enhances EER in full and part load operation (TTC)
+ Inverter-controlled pump ensures constant water ow + Automatic refrigerant pump down combined with leak detection enable the DCC and DCF to contribute to a building achieving 1 BREEAM point
10
Screw
Scroll
ESEER up to 4.01
with OPC, for optimum operating efciency
KEY SPECIFICATIONS:
HEAT PUMP
+ ETL listed* (all OPC models) + 52 models (OPC) and over 200 models (OFC) + Quiet and Extra Quiet ranges + Dual independent refrigeration circuits for resilience + Up to 95% free-cooling with OFC + 12.5C increase in operational evaporating temperature range allowing supply water temperatures to be increased, thus raising the freecooling threshold and giving enhanced compressor efciency and reduced power input (OFC) + Intelligent head pressure control, optimises performance (OFC only) + Latest fan technology reduces sound and power input + 8 stages of cooling for more precise capacity match + Large surface area condensing coils + High efciency shell and tube evaporator
EC
+ Heat pump ideal for comfort applications + Full and exible hydronics package available + Soft start to reduce transient starting peaks
CONTROLS
SERVICE
TRAINING
EER: Energy Efciency Ratio ESEER: European Seasonal Energy Efciency Ratio COP: Coefcient of performance
11
Chillers
Scroll
Scroll
Up to 95% free-cooling
per annum
Up to 62% free-cooling
of UCFC DX performance
+ ETL listed* + 75 models (UCC) and 45 models (UCFC) + Standard, Quiet and Super Quiet variants
KEY SPECIFICATIONS:
FREE COOL
EC
FREE COOL
OPTIONS
+ Single and dual circuit models (UCC 30 - 80kW); dual circuit on UCFC and all larger UCC models + Modulating head pressure control
OPTIONS INCLUDE
+ Exceptional part load efciencies + Direct-drive axial fan + Efcient plate evaporator with EEV refrigerant controls + Large surface area condensing coils maximise energy efciency + Connects to direct rack cooling systems (individual or multi-rack) + Expandable, exible solution as load increases + Modular design plus condensing coils and water connections at the rear, allow close side-by-side positioning + Reduced minimum system water volumes
EC
12
Scroll
Our target is to reduce building energy costs by 7% annually which we have achieved over the past two years. Airedales free-cooling chillers are already contributing to 3% of this annual saving. We make the equipment work through a complete and positive partnership with Airedale, from design through to service and maintenance.
Paul Lovegrove, General Affairs Assistant Manager, Epson
Data centres Clean rooms Ofces Retail outlets Leisure environments Process cooling
KEY SPECIFICATIONS:
**Pictured
CONTROLS
SERVICE
TRAINING
EER: Energy Efciency Ratio ESEER: European Seasonal Energy Efciency Ratio
13
BluCube
HFC R410A
HFC R410A
HFC R407C
KEY SPECIFICATIONS:
OPTIONS
EC
DIGITAL
EC
+ Compressor attenuation reducing compressor sound by up to 12dBA + Integrated condensate drip tray (heat pump models)
14
HFC R407C
CU1 - CUS4
3 - 13kW total heat rejection
+ 8 models: Cooling only and heat pump variants + Reciprocating compressor
HFC R407C
KEY SPECIFICATIONS:
HEAT PUMP
+ Wall mountable, freeing up oor space + Small footprint with slimline design + Head pressure control optimising efciency
OPTIONS
EC
HFC R407C
CUS5 - 12
14 - 35kW total heat rejection
+ 5 models: Cooling only and heat pump variants + Floor mounted for external location
HEAT PUMP
+ Low prole
HFC R407C
CUS15 - 30D
40 - 80kW total heat rejection
+ 7 models: Cooling only + Scroll compressors for reduced sound, higher efciency and lower electrical starting currents + Floor-mounted for external locations + Small footprint Maximising your systems efciency 24/7 www.airedale.com
CONTROLS SERVICE TRAINING
15
Performance tested
And proven
Quality is assured by our on-site world class testing and production facilities and the application of the latest manufacturing techniques and continuous improvement. Airedales dedicated test facility is the only purpose-built one of its kind in the UK. Here all our product lines are performance tested for a global market. Accurate test data is produced anywhere from -5C to +55C in controlled ambient environments. The climate test chambers include a hemi-anechoic chamber for accurate measurement of sound data. Load conditions are simulated from early development of a new product through to nal assembly. Customers can witnesstest products to verify duty and energy performance to ensure they will meet operational requirements.
have a positive, Energy efciency was EDF Energy is already Iceland Frozen Foods (IFF) We responsible partnership the crucial factor seeing a PUE of 1.2 has realised savings of with Airedale in which we share knowledge
It is only through Airedales continued site involvement that we can ne tune the system to such an extent. We dont mind spending capital expenditure to recoup such signicant energy savings as these.
Paul Lovegrove General Affairs Assistant Manager, Epson
Airedale proved that its freecooling chiller can save energy and is the right system for us. Anything that improves payback is of interest to the Society. We have also had good service from other Airedale products.
Steven Ward Premises Engineer, Yorkshire Building Society
I believe we are the rst company in the world to install Airedales advanced technology, the TurboChill FreeCool chiller. When the data centre is operating in free-cooling mode, the PUE has been measured at 1.2 and we expect that to reduce further as we install more equipment.
1.5m to date
The typical payback is between six and nine months per store, making Airedale Controls solution extremely attractive operationally and nancially. Its exibility has enabled IFF to carry out a progressive implementation strategy, integrating existing Airedale equipment, as well as new and old systems from other OEMs.
Graham Ireland Building Services Manager, IFF
16
Intelligent controls
The control centre of each of our cooling systems is a sophisticated electronic microprocessor specially developed by Airedale. The intelligent microprocessor uses sensors to send and receive messages to and from active components so they respond and interact. By integrating and sequencing components, the controller manages and optimises the systems performance, availability and power draw, giving the operator complete system control. Fully-programmable via the control panels user-friendly display, the microprocessor can be linked with all standard BMS protocols to:
Send alarm/service messages via email or SMS using an interface Allow adjustment of temperature setpoints
Integration protocols
Generator/ UPS/Server
Building lighting
17
National Gallery
> 6 x TurboChill chillers supplying chilled water to a primary circuit The TurboChill replace existing R22 chillers with a bespoke, sequenced chiller solution, integrating new technologies; modern refrigerant and design criteria and increased control Benets: ESEER 5.87 16,000 energy saving in rst year Enhanced reliability and less maintenance Matches existing rooftop space and connections
18
Total support
Customers with critical sites can benet from our remote monitoring facility. After-sales services include chiller sequencing, network setup and integration as well as a live demonstration and training centre at our headofce.
Knowing you have immediate help on hand day or night, is reassuring particularly if you are responsible for keeping critical systems operational 24/7. Realise the full potential of your system; improve its longevity and efciency and be F Gas compliant. Avoid downtime with our fast, efcient spares service.
Learn more about your cooling system by attending an air conditioning and refrigeration course in our purpose-built training school. Train on hightech cooling systems and fully operational rigs in our dedicated workshops. Industryrecognised courses also available.
* For customers outside the UK, our international distributors trained by Airedale would be pleased to offer service on Airedale units
Distributed by:
Airedale International Air Conditioning Limited | Leeds Road, Rawdon, Leeds LS19 6JY, England Tel: +44 (0) 113 239 1000 Fax: +44 (0) 113 250 7219 E-Mail: enquiries@airedale.com
All specications are subject to change without prior notice | ENG-PRODG-08-12
www.airedale.com