You are on page 1of 5

Comparison of paralleling and bisecting angle techniques

ENDODONTICS

COMPARISON OF PARALLELING AND BISECTING ANGLE TECHNIQUES IN ENDODONTIC WORKING LENGTH RADIOGRAPHY
M. FAHIM IBRAHIM BDS, FCPS MALIK SALMAN AZIZ BDS, FCPS 3 ANSER MAXOOD BDS, MSC, FRACDS 4 WAHEED ULLAH KHAN BDS, FCPS
1 2

ABSTRACT This cross sectional comparative study was carried out to compare paralleling technique (PT) and bisecting angle technique (BAT) for working length radiography in endodontics. A sample of 120 patients was selected through purposive sampling. The patients were divided into two groups depending on the arch to be radiographed namely Group A for maxillary arch and group B for patients with mandibular teeth requiring endodontic radiography. Each patient underwent two radiographs, one with each paralleling and bisecting angle techniques respectively giving a total of 240 radiographs. Endo Ray II film holder (Dentsply) was used for PT while a hemostat was utilized for BAT. The results showed a higher accuracy in terms of decreased procedural errors with paralleling technique as compared to bisecting angle technique for teeth in maxillary arch (p<0.05), whereas for mandibular arch there was insignificant difference (p>0.05) between the two techniques. Overall paralleling technique was found to have better results than bisecting angle technique, during endodontic working length radiography. Key Words: Radiographs, Paralleling technique (PT), Bisecting angle technique (BAT), endodontic radiography, working length. INTRODUCTION Radiography being a traditional part of dentistry has been considered as the most appropriate method of obtaining information of the root canal anatomy and its surrounding tissues.1,2 Working length (WL) radiography forms an indispensible part of root canal treatment and an accurate WL determination is the most important step on the route to successful root canal treatment.
1 2

The major requirement of WL radiograph is to give a reproducible image of the root canal system, which is needed for an adequate root canal filling. Success of a WL radiograph depends upon the technique used. According to endodontic literature, two radiographic techniques have been employed to capture an image of the tooth and its root onto a periapical film namely the paralleling and bisecting angle techniques. Paralleling technique employs a film holder while a needle holder or finger is utilized to hold the film during bisecting angle technique.3,4 An adequate picture of the root and the tooth would mean that the tooth is visible on the film from the coronal reference point to the apical area of the root. Dose of radiation for periapical radiographs, although minor, should not be taken for granted and suitable means should be utilized to decrease it as much as possible. Keeping in mind the imperative 160

Resident Dental Surgeon, Ministry of Health KSA Assistant Professor & Head of Department of Periodontology, College of Dentistry, University of Lahore, Lahore Corresponding Author: email: drsalmanaziz@gmail.com, Mob: 03335698030 Professor & Head of Department of Dentistry, Pakistan Institute of Medical Sciences, Islamabad Assistant Professor, Department of Orthodontics Islamabad Medical & Dental College, Islamabad Received for Publication: Revision Accepted: March 2, 2013 March 31, 2013

Pakistan Oral & Dental Journal Vol 33, No. 1 (April 2013)

Comparison of paralleling and bisecting angle techniques

nature of WL radiography in endodontics and extra dose of radiation, errors during endodontic radiography should be minimized.5 Whenever there is need for multiple radiographs, the above mentioned periapical radiography techniques have certain merits and demerits which govern the repetition of WL radiographs in clinical situations such as the arch form, the tooth shape, it location and position, along with radiographers technique.6 In order to reduce the amount of retake during WL radiography, these techniques need to be evaluated effectively to determine the factors leading to repeat in order to devise efficient means to counteract them. The purpose of this cross-sectional study was to compare the efficacies and errors of Paralleling technique (PT) and Bisecting angle technique (BAT) when used for endodontic working length determination. MATERIALS AND METHODS This cross sectional comparative study was conducted in the Dental department of Pakistan Institute of Medical Sciences (PIMS) Islamabad. A total of 120 patients requiring root canal treatment were selected utilizing convenience sampling, and divided into two groups based upon the arch to be radiographed, namely Group A and B. Former consisted of patients requiring root canals of maxillary arch while the latter consisted of 60 patients requiring endodontic radiography for mandibular teeth. Inclusion criteria Patients included consisted of those requiring root canal treatment (RCT) due to pulpal necrosis, trauma involving the pulp chamber, irreversible pulpitis, retreatment, intentional root canal treatment. Root canals allowing minimum entry for # 15 file were included. Exclusion criteria Patients having teeth with sclerosed canals, root resorption, blunderbuss canals and severe periodontitis, teeth requiring re root canal treatment, were excluded from the study.
Pakistan Oral & Dental Journal Vol 33, No. 1 (April 2013)

Data collection procedure After access opening and pulpectomy, endodontic working length (EWL) radiographs were taken with # 15 K files (Manni, Japan) using both the radiographic techniques, namely BAT and PT, on the same tooth utilizing 3x4 cm periapical size films (M-2 Comfort, Speed E, Agfa Dentus, Hanau, Germany). A single researcher took all the radiographs using the EndoRay II film holder (Dentsply Rinn Co, Japan) and hemostat (51/2 inch, Advance Co, Sialkot, Pakistan) for PT and BAT respectively (X-ray unit, explorer x-70 (Villa Syestemi Medical, Italy). Data was collected onto a proforma and the results recorded as acceptable or unacceptable. Radiographs covering the entire tooth being treated including the apices of all the involved roots and at least 2mm of peri radicular bone were considered acceptable (A). If a film was rated unacceptable (UA), the reason for error was recorded. Data analysis was done using SPSS version 11. Descriptive analysis was done for continuous variables such as age, and frequency and percentage were calculated for categorical variables such as EWL Radiograph outcome in terms of acceptability. Comparative analysis was done using chi-square test and pvalues were recorded.

Fig 1: Distribution of gender in all the patients (n = 120) 161

Comparison of paralleling and bisecting angle techniques

RESULTS The age of the patients ranged between 15-50 years with a mean of 31.7 7.1 years. Males accounted for 45% (n=53) while 55% (n=67) of the patients were female as shown Fig 1. In Group A, with paralleling technique (PT) (n=60) the retake (unacceptable radiographs) was 10% (n=6), while 18 out of 60 radiographs (30%) were repeated when bisecting angle technique (BAT) was employed, as shown in Table 1. A significant difference for retake between PT and BAT was found (p= 0.01). In Group B patients, the retake (unacceptable radiographs) was 11.7% (n=7) with PT while with TABLE 1: COMPARISON OF OUTCOME (ACCEPTABLE V/S UNACCEPTABLE) IN PARALLELING (PT) AND BISECTING ANGLE TECHNIQUES (BAT) IN MAXILLARY GROUP (A) (N = 120) Endodontic Working Length Acceptable Unacceptable PT (n = 60) BAT (n = 60) p-value 0.01 Fig 2: Distribution of different reasons for unacceptability overall in two techniques (n= 42) bisecting angle technique retake was done in 11 patients (18.33%). There was insignificant difference between PT and BAT in group B patients, (p=0.44). Table 2 Apex incomplete, Elongation and Cone cut were the three reasons for unacceptability among the samples. Fig 2 Overall statistically a high level of significance i.e. p=0.01 was seen when PT and BAT are compared regardless of the region being radiographed as shown in Table 3. DISCUSSION TABLE 2: COMPARISON OF OUTCOME (ACCEPTABLE V/S UNACCEPTABLE) IN PARALLELING (PT) AND BISECTING ANGLE TECHNIQUES (BAT) IN MANDIBLE GROUP (B) (N = 120) Endodontic Working Length Acceptable Unacceptable PT (n = 60) BAT (n = 60) p-value 0.44 A significantly higher proportion of retake due to errors was found with BAT (24.16%), as compared to PT (10.83%). This shows that the paralleling technique produces less distortion and is less variable as is supported by the results of various other studies7 therefore paralleling technique principle is more reliable than the bisecting-angle.8 According to many authors only the paralleling extended-distance technique provides the minimum of dimensional distortion.9

54 (90.0%) 42 (70.0%) 6 (10.0%) 18 (30.0%)

53 (88.3%) 49 (81.7%) 7 (11.7%) 11 (18.3%)

TABLE 3: COMPARISON OF OUTCOME (ACCEPTABLE AND UNACCEPTABLE) IN PARALLELING (PT) AND BISECTING ANGLE TECHNIQUES (BAT) IN ALL PATIENTS (N = 240) Technique used PT BAT Total Number 120 120 Acceptable 107 (89.2%) 91 (75.8%) Unacceptable 13 (10.2%) 29 (24.2%) 162 p-value 0.01

Pakistan Oral & Dental Journal Vol 33, No. 1 (April 2013)

Comparison of paralleling and bisecting angle techniques

In 1994, Gound10 conducted a study in which he compared the accuracy of different operators when taking radiographs for endodontic procedures, where as in current study, PT and BAT were compared utilizing a single operator in order to eliminate the inter-operator variability element. Maxillary teeth Group (A) especially the molars in this study were found to be more difficult to radiograph than mandibular teeth Group (B) utilizing both radiographic techniques. Several other authors had the same difficulty.10-14 One explanation for having this problem is the rigidity of palate and most of the palatal vault slopes, with the highest and flattest between the molars.10 To overcome this problem according to Walton15 the film must be placed in the highest part of vault which is at considerable distance from the tooth. Of the studies that compared film holders, Bean16 and Forsberg14,17 reported, radiographs taken with holders that had a positioning arm to guide alignment and that were designed to allow patients to bite together, while the film was exposed, had a lower unacceptability (retake) rates than holders without these advantages.10 Endo-Ray II is one of the film holders having both the above mentioned advantages. This holder was selected purely because of its availability and a design, which accommodates the files (basket) during Endodontic WL radiograph and at the same time provides a base to bite on for the patient and hence helps in the stability of the cone indicator (external arm and ring) and the film. The disadvantages of the Endo-Ray II are that it requires assembly before use, and is difficult to place in patients with shallow palatal vaults or restricted mouth opening. During its use in Group (A) 90% of the radiographs were acceptable, while when used in Group (B) 88.33% were acceptable. Higher rate of unacceptability, while using EndoRay II in mandibular arch, was probably due to hindrance from the tongue and lack of space for the basket in mandibular anterior region. Over all lower retake value with Endo-Ray II holder might be because the film is held in a more vertical position and the cone indicator arm guides the operator to accurately determine how the film is aligned.
Pakistan Oral & Dental Journal Vol 33, No. 1 (April 2013)

The results using hemostat as film holder i.e. with BAT showed 70% acceptability in Group A while 81.66% acceptability in Group B. These results clearly indicate that statistically there is no significant difference when either of the two film holders were used in Group B probably due to the reason that the floor of the mouth does not slope and is flexible, so x-ray films can be placed close to the tooth and parallel to the its long axis with either holders. A higher rate of unacceptability, 30%, seen while using hemostat (BAT) in the Group A may be because the films placed away from the tooth usually are aligned at an angle to the long axis of tooth rather than being parallel to it. These results advocate the use of film holders for endodontic periapical radiography as was also seen in the Rushtons study.18 The major criterion of unacceptability in this study was that the radiographs do not cover the entire tooth being treated including the apices of all the roots and at least 2mm of periradicular bone.19 Other criteria included cone cut, fore shortening and elongation. The major reason for unacceptability in both the groups was found to be incomplete/inadequate apical coverage; 11 (9.16%) with PT (n=120) and 14 (11.6%) with BAT (n=120) as shown in graph 2. This finding agrees with the findings of Bean 16 , Gound and Dubois10, Lim and Teo13 who reported that the failure to include the apex was the most frequent of errors in their study. Cone cut, caused by improper film placement or cone angulation was found to be the second most common reason for unacceptability overall in both the study groups; 2 (1.66%) with PT (n=120) and 11 (9.16%) with BAT (n=120) as shown in graph 2. This result of our study is supported by similar results of studies carried out by Mourshed11 and Patel20 which stated that improper film placement is the most frequent cause of errors. Due to elongation only 4 EWL radiographs i.e. 3.33%, graph 2, were retaken when BAT (n=120) was employed whereas when using PT (n=120) no elongation was caused. Elongation results when the x-ray beam is directed perpendicular to the long axis of the tooth rather than through the bisecting line. This was the third most frequent cause of unacceptability in the current study. 163

Comparison of paralleling and bisecting angle techniques

CONCLUSION In endodontics, the paralleling technique has a geometrical advantage over the bisecting angle technique and results in less number of EWL radiographs leading to overall fewer amounts of radiation exposure and discomfort to the patient along with saving time and the cost of an extra film. PT i.e. use of the EndoRay II film holder is more desirable for EWL radiography as it can significantly minimize the amount of retakes. However, there are instances where the bisecting angle is preferable, and consideration should be given to this technique to improve the image quality when it is used. Film holder should be used where required yet it should be remembered that the film holder is an indicating device, not a dictating one. REFERENCES
1 2 Bramanet CM, Berbert A. A critical evaluation of some methods of determining tooth length. Oral Surg 1974; 37: 463. Forsberg J. Radiographic reproduction of endodontic working length comparing the paralleling and the bisecting-angle techniques. Oral Surg Oral Med Oral Pathol 1987; 64(3): 353-60. Langland OF, Langlais RP, Preece JW. Principles of dental imaging. In: Langland OF, Langlais RP, Preece JW. Intraoral radiographic techniques. 2nd ed. Philadelphia: Lippincott Williams & Wilkins, 2002: 91-97. Jhon PR. Essentials of Dental Radiology. In: Jhon PR. Intraoral radiographic techniques and indications of intraoral radiographs. 1st ed. New Delhi: Jaypee Brothers, 1999: 75-81. Whaites E, Cawson RA. Essentials of dental radiography & radiology. In: Whaites E, Cawson RA. Radiation protection. 3rd ed. London: Harcourt publishers, 2002: 53-59. Manson-Hing LR, editor. Intraoral radiographic techniques. In: Manson-Hing LR. Fundamentals of dental radiography. 2nd ed. Philadelphia: Lea & Febiger, 1985: 45-73.

Biggerstaff RH, Phillips JR. A quantitative comparison of paralleling long-cone and bisection-of-angle periapical radiography. Oral Surg Oral Med Oral Pathol 1976; 62(5): 673-7. Forsberg J. Radiographic reproduction of endodontic working length comparing the paralleling and the bisecting-angle techniques. Oral Surg Oral Med Oral Pathol 1987; 64(3): 353-60. Rimondini L, Baroni C, Venturi M. Radiographic control in endodontics. Dent Cadmos 1990: 15; 58(19): 46-8, 51-2. Gound GT, DuBois L, Biggs SG. Factors that effect rate of retakes for endodontic treatment radiographs. Oral Surg Oral Med Oral Path 1994; 77: 514-8. Mourshed F. A study of intra oral radiographic errors made by dental students. Oral Surg Oral Med Oral Pathol 1971; 32: 824-8. Tamse A, Kaffe I, Fishal D. Zygomatic arch interference with correct radiographic diagnosis in maxillary molar endodontics. Oral Surg Oral Med Oral Pathol 1980; 50: 563-5. Lim K, Teo C. Some problems encountered in endodontic radiography. Ann Acad Med Singapore 1986; 15: 320-5. Forsberg J. Estimation of root filling length with the paralleling and bisecting angle techniques performed by under graduate students. Int Endo J 1987; 20: 282-6. Walton R. Endodontic radiography. In: Walton R, Torabinejad M. Principals and practice of endodontics. Philedephia: WB Saunders, 1989: 141-2. Bean L. Comparison of bisecting angle and paralleling methods of intraoral radiology. J Dent Educ 1969; 33: 441-5. Forsberg J. A comparison of paralleling and bisecting angle radiographic techniques in endodontics. Int Endo J 1987; 20: 177-82. Rushton VE, Horner K. A comparative study of radiographic quality with five periapical techniques in general dental practice. Dentomaxillofac Radiol. 1994; 23(1): 37-45. Langland OF, Langlais RP, Preece JW. Principals of dental imaging. In: Langland O, Langlais RP, Preece JW. Production of X-rays. 2nd ed. Philadelphia: Lippincott Williams & Wilkins, 2002: 16-19. Patel JR. Intraoral radiographic errors. Oral Surg Oral Med Oral Pathol 1979; 48: 479-83.

9 10

11

12

13 14

15

16 17

18

19

20

Pakistan Oral & Dental Journal Vol 33, No. 1 (April 2013)

164

You might also like