Professional Documents
Culture Documents
Daikinistheonlycompanyintheworlddedicatedtomanufacturingboth airconditioningsystemsandrefrigerants.Eachelementhasbeendesigned toworkflawlesslywiththenext deliveringoptimalperformance from thetimeaprojectbeginstothemomentofexperiencingabsolute comfort. Daikinsadvancedresidentialandcommercialsystemscandeliverabsolute comforttopracticallyanybuildingofanyshape,size,andage.Thatswhy itstheidealsolutionforschools,hotels,offices,hospital,homes,stores, restaurantsandmuchmore.WithDaikin,youcancreatearesponsive environmentthatcanconstantlyreadjustitselftoyourchangingneeds.
ENERGYEFFICIENCY
Integratedwithaninvertervariablespeedcompressor,allsystemsvary compressorspeedtodelivertherequiredheatingorcoolingcapacity neededtomaintaindesiredcomfortconditions,minimizingtemperature fluctuationsandmaximizingenergysavings.
ADVANCEDZONINGCAPABILITIES
Modularindesign,Daikinsystemsprovideindividualzonecontrolno matterhowsmallorlargetheapplication.Fromsingleroomsolutionsto largecommercialoptions,Daikinprovidesadvancedsolutionswithcomfort controlfeatures.
RELIABILITY
Engineeredforreliability,allmajorcomponentsaredesignedand manufacturedbyDaikintoensuremaximumperformanceanddurability. Fromtheinternalandexternalcomponentstothenonozonedepleting potentialR410A,Daikinsystemsoptimizeenergyconservationandis backedbyoneofthebestwarrantiesintheindustry. Formoreinformation,visit www.daikincare.com
TableofContents
KeyFeatures&Benefits.. SplitSystemsOverview.. Features ... KESeriesSEER18 WallMountHeatPump/CoolingOnly LVSeriesup toSEER15.5 SlimDuctHeatPump.. LV SeriesuptoSEER24.5 WallMountHeatPump. Quaternity uptoSEER26.1 WallMountHeatPump.... MultiSplitSystems...... Controls.... DaikinENViThermostat(DACATS11). DaikinAlthermaOverview .. SplitSystems.... MonoBloc Systems... SkyAirOverview..... Features... Wall Mounted(FAQ&FTXS) HeatPumporCoolingOnly.... DCDuctConcealed(FBQ) HeatPumporCoolingOnly.. Round FlowCassette(FCQ) HeatPumporCoolingOnly. Ceiling Suspended(FHQ) HeatPumporCoolingOnly. Daikin InverterDucted(FTQ) UnitaryHeatPump... Controls.. VRVOverview VRVIIIS.. VRVIII AirCooled HeatPumporHeatRecovery. VRVWIIIWaterCooled HeatPumpandHeatRecovery... InstallationSpace IndoorUnits... Controls..... NavigationRemoteController(BRC1E72) IntelligentTouchController.. IntelligentTouchManager VRVAccessories 4 6 7 9 10 11 12 14 20 21 22 24 25 26 27 28&29 30 31 32 33 35 36 38 40 46 54 56 70 71 73 74 75
VRV
SkyAirSystems
Daikin Altherma
SplitSystems
KeyFeaturesandBenefits*
SuperiorComfortControl
IndoorUnitQuietOperation.Soundlevelsare reducedby23decibels(dB)fromthelowfan speedforquieterandgentlerheatingand cooling. OutdoorUnitQuietOperation.Outdoorunit soundlevelscanbereducedby3dBfortimes whenquieteroperationisneeded. IntelligentEye.Theintelligenteyeisaninfrared sensorwiththeabilitytosensemovementin theroom.Whenyouareintheroom,theair conditioneroperatesnormally.Ifyouleavethe roomformorethan20minutestheair conditionerautomaticallychangestoanenergy savingoperation.Usingtheintelligenteye, savingsofupto20%incoolingandupto30%in heating,canbeachieved. AutomaticOperation.Forunattendedyear roundcomfort,thisfunctionallowstheunitto automaticallyswitchbetweenheatingand coolingmodesasrequired. ProgramDryFunction.Thisgivespriorityto reducingthelevelofhumidityintheroom ratherthanroomtemperature. AutoFanSpeed.Toreduceoperatingsound andpowerconsumption,thefanspeedis automaticallycontrolledbythemicroprocessor tosuitthecontrollersettingandprevailing roomtemperature. HotStart.Whentheheatingoperationstartsor whentheunitchangesfromcoolingtoheating thereisnocolddraftreleasedintotheroom. RemoteControllerwithBacklitDisplay. FeaturesabacklitLCDandluminescentcontrol buttons,allowingforeasyviewingindimlylit rooms. HomeLeaveOperation.Selectthisenergy savingfunctionwhenleavingthehouseandthe airconditionerwilloperateatapreselected temperature.Yourhomecanthenbewarmed orcooledmuchquickeruponyourreturn.Itcan alsobeusedtorecordyourpreferred(default) settings. IndoorUnitOn/OffSwitch.Aconvenienton/off switchontheindoorunitallowsyoutostartup thesystemevenifyouhavemisplacedthe remotecontrolortheremotecontrolbatteries areexhausted.
ComfortableAirflow
WideAngleLouvers.Smoothlycurvedwide anglelouversprovidewideairflowcoveragefor effectiveheatingandcoolingnomatterwhere theindoorunitisplacedwithintheroom. DualFlapSystem.Thisuniquesystemdirects warmairtothefloorinwinterandcoolair acrosstheroominsummerformaximum efficiencyandcomfort.Thelargeflapgoverns airflowdirectionwhilethesmallflap(or diffuser)swings,producingfineaircurrentsthat helpcirculatetheairaroundtheroom. ComfortableMode.Thenewflapchangesthe deliveryangletohorizontalforcoolingand verticalforheatingoperation,topreventcold orwarmairfromblowingdirectlyontoyour body. VerticalAutoSwing(upanddown).The verticalautoswingautomaticallysweepstheair acrosstheroominanupanddownmotion. Whentheunitisswitchedoff,thelouversclose automatically. HorizontalAutoSwing(leftandright). Automaticallymovestoensureaneven distributionofairthroughoutaroom. 3DAirflow.Combinesverticalandhorizontal autoswingtocirculatecool/warmairtothe cornersoflargespaces.
LifestyleConvenience
EconoMode. Limitsthemaximumoperating currentandpowerconsumptionoftheoutdoor unitbyapproximately30%duringstartup.This savesenergyandreducestheloadonthe electricalcircuitwhenmultipleelectrical devicesareusedsimultaneously. PowerfulOperation.PushingthePOWERFUL buttonontheremotecontrolgivesyouaboost incoolingorheatingpowerfora20minute period,eveniftheunitisalreadyoperatingat highcapacity. *Pleaserefertoindividual productforavailability.(pg7)
4
WorryFree
AutoRestart.Theunitmemorizesthe operationmode,airflowandtemperature settings.Shouldtherebeapowerfailurewhen theunitisinoperation,itwillautomatically returntothesameoperatingconditionswhen thepowerisrestored. SelfDiagnosis.Intheeventthataproblem developswiththeunit,malfunctioncodescan bedisplayedontheliquidcrystalpanelofthe remotecontrolforfastandeasyfaultdiagnosis. AntiCorrosion.Thespecialanticorrosion coatingontheoutdoorunitheatexchanger ensuresgreaterresistancetosaltdamageand atmosphericcorrosion.
Timers
24HourOn/OffTimer.Thetimercanbepreset tostartandstoptheairconditioneratanytime withina24hourperiod.Oncethetimesareset, theairconditionercanbeoperatedforaperiod bysimplypressingtheONorOFFtimerbuttons. WeeklyTimer.Theweeklytimerfunction makesiteasytoenteruptofoursettingsper dayforeachdayoftheweek.Theweeklytimer functionnotonlyallowsyoutoprogramonand offtime,butalsothedesiredtemperature. NightSetMode.ThroughtheuseoftheTimer OFFCircuit,thepresetroomtemperature gentlyrisesincoolingorfallsinheatingbefore theunitstops.Thisenergysavingfeatureallows youtosleepcomfortablywithoutfeelinga suddenchangeintheroomtemperature,while atthesametimesavingenergy.
HealthyandClean
AirPurifyingFilterwithPhotocatalytic DeodorizingFunction.Thiscombination operatesasahighlyeffectiveunit.Thefilter attractsmicroscopic particlesthatcancarry bacteriaandvirusesandcanfiltercanbeused forapproximatelythreeyearsifperiodic maintenanceisperformed. TitaniumApatitePhotocatalyticAirPurifying Filter.Thisfiltercombinestheairpurifyingfilter andtitaniumapatitephotocatalytic deodorizing filterinasinglehighlyeffectiveunit.Thefilter trapsmicroscopicparticles,decomposesodors andevenadsorbsanddeactivatesbacteriaand viruses.Itlastsforthreeyearswithout replacementifwashedonceeverysixmonths. MoldProofAirFilter.Theprefilternetis impregnatedwithasafe,colorlessandodorless moldpreventative.Thisrendersthefilter virtuallyimmunetomold. WipeCleanFlatPanel.Theflatpanelmodels canbecleanedwithonlythesinglepassofa clothacrosstheirsmoothsurface.Theflatpanel canalsobeeasilyremovedformorethorough cleaning.
KeepingWarm
QuickWarmingFunction.Preheatsthe compressortoshortenthetimerequiredto dischargewarmair. AutomaticDefrosting.Sensorperforms automaticdefrostingoftheoutdoorheat exchangerifnecessary,ensuringoptimum heatingperformance.
Tax Credit
TaxCreditQualified. Daikinsellsproductsthat maybeeligiblefortaxcreditopportunities. Formoreinformation,pleasevisit www.daikinac.com.
SplitSystems
Fromonetoonesolutionsforsingleroomenhancementstomultizonesolutionsforflexibilityina spacesavingdesign,splitsystemsprovidecomfortforalmostanyresidentialapplication.Asaglobal leaderandinnovator,Daikinprovideshomecomfortsolutionsdesignedforenergyefficiency,builtin reliability,andindividualtemperaturecontrol.
Energy Efficient Integratedwithaninvertervariablespeed compressor,systemsdeliverthecapacityrequiredto maintaindesiredroomconditions,typicallyreducing energyconsumptionby30%comparedtotraditional fixedspeedsystems.Thistechnologyminimizes temperaturefluctuationsandprovidescontinuous coolingandheatingcomfortwithmaximumenergy savings.
Upto
Upto
13
Federal min.
18
standard
24.5
better
26.1
best
IndividualTemperatureControl Individualtemperaturecontrolprovidescomfortfortheentirespace.Eachsystemisequippedwitha wirelessremotecontrol,providingtheabilitytochangethesettingsanywhereinthecomfortofthe conditionedspace.Alargedisplayprovidesanoverviewoftheunitsoperationanduserfriendly buttonsofferadvancedcapabilitiesfromtemperaturecontroltoenergysavingfeatures. Reliability AllmajorcomponentsareengineeredandmanufacturedbyDaikin,ensuringmaximumperformance, reliabilityandefficiency.Fromtheinternalmotorsandcompressorstotheexterioranticorrosion treatmentandselfdiagnosticfunction,Daikinsystemsarebuiltwithdurabilityandbackedbyoneof thebestwarrantiesintheindustry.
6
SplitSystemFeatures
SingleSplit Type MultiSplit
Split Systems
Cool Heat Heat Heat Heat Heat Heat Heat Heat Heat Heat Only Pump Pump Pump Pump Pump Pump Pump Pump Pump Pump
FTXN_K(E)
FTXN_K(E)
CDXS_LV
FDXS_LV
FDXS_LV
CTXS_LV
FTXS_LV
FTXS_LV
FTXG_H
CTXS_H
Models PulseAmplitudeModulation ComfortableAirflow PowerAirflowDualFlaps WideAngleLouvers VerticalAutoSwing(upanddown) HorizontalAutoSwing(leftandright) 3DAirflow ComfortableMode IndoorUnitQuietOperation ComfortControl OutdoorUnitQuietOperation IntelligentEye AutomaticOperation ProgramDryFunction AutoFanSpeed HotStart HealthyandClean MoldProofAirFilter AirPurifyingFilterwithPhotocatalytic DeodorizingFunction TitaniumApatitePhotocatalytic AirPurifyingFunction FlashStreamer WipecleanFlatPanel StandbyElectricitySaving EconoMode Lifestyle PowerfulOperation RemoteControllerwithbacklitdisplay LCDWirelessRemoteControl HomeLeaveOperation IndoorUnitOn/OffTimer Timers 24HourOn/OffTimer WeeklyTimer NightSetMode WorryFree AutoRestartafterPowerFailure SelfDiagnosiswithDigitalDisplay AnticorrosionTreatmentofOutdoor Heat ExchangerFin
FFQ_LV
K(E)Series(SEER18)
Split Systems
Elegantdesignwithcomfortcontrolfeatures.
Keyfeaturesinclude: Standbyelectricitysavingreduceselectricity consumptionbyupto90%whentheunitisnotin operation. Economodedecreasespowerconsumptionduring startupwhenotherappliancesneedmorepower. Titaniumapatitephotocatalytic airpurificationfilter decomposesodorsandattractsmicroscopicparticles thatcancarrybacteriaandviruses. Whisperquietoperationwithsoundlevelsaslowas 22dB(A). Availablefrom9,000Btu/hto24,000Btu/hinheat pumpandcoolingonlymodels.
9,000 4,400 - 9,500 10,000 4,400 - 11,600 18.0 3.49 12.0 8.5 4.8 15.0 750 840
12,000 4,400 - 12,000 13,500 4,400 - 16,400 18.0 3.25 9.9 8.5 7.0 15.0 1,210 1,220
V/ph/Hz A A W W
15,000 5,800 - 15,000 18,000 5,800 - 21,200 18.0 3.05 12.0 8.5 208-230/1/60 15.5 20.0 1,250 1,730 FTXN15KVJU 0.77 519/438/364/335 568/491/406/360 45/41/36/33 44/40/35/32 1/4 1/2 11/16
18,000 5,800 - 18,000 21,600 5,800 - 24,000 18.0 2.88 12.0 8.5 15.5 20.0 1,500 2,200
22,000 5,800 - 22,000 24,000 5,800 - 25,400 18.0 2.78 8.6 8.5 15.5 20.0 2,560 2,530
LVSeries(UptoSEER15.5)
Compactandsliminheightforflexible,hidden design.
Keyfeaturesinclude: Indoorunitandoutdoorunitquietfunctionsreduce soundlevelsby23dB(A)forgentlerheatingand coolingandwhisperquietoperation. Standbyelectricitysavingreduceselectricity consumptionbyupto90%whentheunitisnotin operation. Economodedecreasespowerconsumptionwhen otherappliancesneedmorepower. Powerfuloperationprovidesrapidheatingorcooling. Availablein9,000Btu/hand12,000Btu/hinheat pumpmodels.
V/ph/Hz A A W W
LVSeries(UptoSEER24.5)
Split Systems
Sleekdesignwithenergysavingfeatures.
Keyfeaturesinclude: Intelligenteyeadjustsbetweennormaloperationand energysavingmodebyutilizingamotiondetecting sensortomonitoroccupancy,resultinginsavingsup to20%inheatingand30%incooling. Weeklytimerprovidescustomizable7daycomfort withtheabilitytoprogramupto4settingsperday. 3Dairflowcombinesverticalandhorizontalauto swingtocirculatewarmorcoolairthroughoutlarge spaces. Titaniumapatitephotocatalytic airpurificationfilter decomposesodorsandattractsmicroscopicparticles thatcancarrybacteriaandviruses. Availablefrom9,000Btu/hto24,000Btu/hinheat pumpmodels. LV Series High Efficiency System Performance
Cooling Capacity (Rated) Cooling Capacity (Min Max) Heating Capacity (Rated) Heating Capacity (Min Max) SEER COP EER HSPF Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Power Consumption - Cooling Power Consumption - Heating Model Name Moisture Removal Airflow-Wet (H/M/L/SL) Airflow-Dry (H/M/L/SL) Sound Pressure - Cooling (H/M/L/SL) Sound Pressure - Heating (H/M/L/SL) Liquid (O.D.) Piping Connections Gas (O.D.) Condensate Drain Dimensions (H x W x D) Net Weight Model Name Sound Pressure Level - Cooling Sound Pressure Level - Heating Operating Range - Cooling Operating Range - Cooling with Optional Wind Baffle Operating Range - Heating Max. Piping Length Max. Piping Height Dimensions (H x W x D) Net Weight Btu/h Btu/h Btu/h Btu/h 9,000 4,400 - 10,600 9,000 4,400 - 15,600 24.5 4.46 15.3 12.5 8.00 15.0 590 790 12,000 4,800 - 13,800 14,400 4,800 - 18,000 23.0 4.35 12.8 12.5 8.75 15.0 940 970 15,000 5,800 - 18,000 15,000 5,800 - 22,300 20.6 4.00 14.4 11.6 208-230/1/60 13.75 20.0 1,040 1,320 FTXS15LVJU 0.8 568/477/385/360 593/505/417/371 45/40/35/32 43/38/33/30 1/4 1/2 5/8 31.0 RXS15LVJU 47/44 48/45 14 - 115 0 - 115 5 - 77 98.4 65.6 104.0 18,000 5,800 - 21,600 18,000 5,800 - 26,700 20.3 3.70 12.7 11.0 13.75 20.0 1,420 1,710 21,500 7,800 - 25,800 25,400 7,800 - 31,400 20.0 3.37 12.5 10.6 17.50 20.0 1,720 2,210
V/ph/Hz A A W W
Quaternity(UptoSEER26.1)
TheQuaternitysystemisdesignedtomaximizecomfortevenunderthemostchallengingweather conditions.Equippedwithbuiltinintelligenceandextensivefeaturesinahighlyefficientsystem, Quaternityprovidesacomfortableandrefreshingindoorenvironmentwithadvancedfiltrationand climatecontrol.
EnergyEfficiency
Integratedwithaninvertervariablespeedcompressor, systemsdeliverthecapacityrequiredtomaintaindesired roomconditions,typicallyreducingenergyconsumptionby 30%comparedtotraditionalfixedspeedsystems.This technologyminimizestemperaturefluctuationsandprovides continuouscoolingandheatingcomfortwithmaximum energysavings.
IncreasedIndoorAirQualitywithFlashStreamerTechnology
DaikinsFlashstreamertechnologyincreasesindoorairqualitythroughapowerfulmultistagefiltrationsystem.Designed withawide,plasmadischargerange,theflashstreamerhasanoxidativedecompositionspeedthatcanfilter1,000times fasterthanconventionalplasmatypesystems.
Plasma Ionizer
DehumidificationWhileMaintainingTemperature
Utilizingintelligentindoorheatexchangertechnology,the systemmixescooldryairwithwarmairtoprovide dehumidificationtoarelativehumiditysettingwhile maintainingroomtemperature.Whetherdehumidifyingis neededonahotsummerdayorawarmrainynight, Quaternitycanprovidearefreshinglycoolexperience
12
Split Systems
RXG_HVJU
FTXG_HVJU
ARC447A3
Heating,cooling,dehumidificationandair purificationinapremiumallinonesystem.
Keyfeaturesinclude: ProvideshighenergysavingswithsystemsuptoSEER 26.1andEER15.8. Controlshumiditylevelstoarelativesetting. Removesallergens,odors,andbacteria withthe FlashStreamerforimprovedindoorairquality. Delivershighheatingcapacityatlowambient temperaturesdownto4F. Offerssimple,userfriendlywirelessinfraredremote controller. Operatesatwhisperquietsoundaslowas26dB(A).
AllQuaternitysystemsqualifyfortheEnergyTax ExtendersofTheAmericanTaxpayersReliefActof2012.
V/ph/Hz A A W W
13
MultiSplitSystems
Daikins2port,3port,4port,and8Zonemultisplit systemscanserveuptoeightroomsfromasingleoutdoor unit.Withindoorunitoptionsconsistingofstreamlined wallmountunits,builtinslimductunits,oracombination ofboth,multisplitsystemsofferover1,000possible connectioncombinations,creatingaflexible,powerfuland energyefficientsystem.
FlexibleinaSpaceSavingDesign Idealforinstallationswhereoutdoorspaceis limited,Daikinsrangeofmultisplitsystemsoffers reducedinstallationspaceevenwhenconnectinguptoasmany aseightindoorunits,maintainingabeautifulhomeexterior. Connectingeachindoorunitbyapairofrefrigerantlines,fewelectrical connections,andlittletonoductwork,indoorandoutdoorunitscanbeeasily installedinexistingspaceswithminordisruptionandofteninasingledayswork. Thecompactandlightweightdesignscombinedwithflexiblepipingandminimal wiringallowinstallationwithminimaltimeandcosts.
PriorityRoomSetting Duringinitialinstallation,apriorityroommaybesettodeliverpreferentialconditioningandcontroloverthefunctions: operationmode,powerfuloperation,andquietoutdooroperation. Operationmodepriority Coolingorheatingoperationmodeintheselectedroomisgivenpriority.Whenadifferentoperation modefromanotherunitisselected,theunitisplacedonstandbyuntilthepriorityroomunitstops operating. Priorityduringpowerfuloperation Whenthepriorityroomisoperatinginpowerfulmode,coolingorheatingcapacitiesfromother indoorunitsmaybetemporarilyreducedtoshiftroomcapacitiestotheprioritizedroom. Quietoperationpriority Quietoperationfortheoutdoorunitcanbeinitiatedbyasinglecommandfromthepriorityroomcontroller. Outdoor Unit
2MXS18GVJU Product Image Wall Mounted Model Number
CTXS07LVJU CTXS09HVJU CTXS12HVJU FTXS15LVJU FTXS18LVJU FTXS24LVJU FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU FFQ09LVJU FFQ12LVJU FFQ15LVJU FFQ18LVJU
3MXS24JVJU
4MXS32GVJU
RMXS48LVJU
Ducted
Official combination
14
Cassette
Split Systems
2MXS
3MXS/4MXS
Flexible,powerfulandenergyefficient
Keyfeaturesinclude: Abilitytoconnectuptofourindoorunitstoasingle outdoorunit. Energyefficientsystems. Reducedinstallationspace. Longpipinglengthsupto230ft. Upto131ft.ofprechargedrefrigerant.
Outdoor Units
Model Name Maximum Capacity Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Sound Pressure - (Cooling/Heating) Operating Range - Cooling Operating Range - Heating Max. Piping Length (for Total of All Rooms) Max. Piping Length (for One Room) Max. Piping Height Dimensions (H x W x D) Net Weight Btu/h V/ph/Hz A A dB(A) F DB F DB ft. ft. ft. in. lbs. 2MXS18GVJU 18,000 11.1 20.0 50/51 14 - 115 0 77 164 82 49.2 28-15/16 x 32-1/2 x 11-13/16 139.0 168.0 3MXS24JVJU 24,000 208-230/1/60 17.8 20.0 52/54 14 - 115 0 77 230 82 49.2 4MXS32GVJU 30,600 18.0 20.0 52/54 14 - 115 0 77 230 82 49.2 168.0
* Per AHRI, the certified ratings for variable-speed, multi-split systems are valid for all combinations of indoor units (based on combination types) with the specific outdoor unit listed above and in the AHRI Directory of Certified Equipment. Visit www.AHRIDirectory.org for further details and independent verification.
15
8ZoneMultiSplitSystems
Daikins4ton(48,000Btu/h)8ZoneMultiSplitheatpumpsystemextendsthe multisplitrangeandoffershighefficiencyandgreaterflexibilityforlargerspaceswiththeability toconnectfrom2to8indoorunits toasingleoutdoorunit.Avarietyofindoorunitsareavailable tomatchthedcorofeachroomwhileofferingindividualroomcontrolforamultipleroomor wholehousecomfortsolution.
DesignFlexibility
The8ZoneMultiSplitSystemisaHighEfficiencysolution withoptimumflexibility.Thesystemofferscomfortable zoningcapabilitieswiththeabilitytoconnectupto8 indoorunitswitheaseutilizinglongpipelengths, standardizedlinesets,simplifiedelectricalrequirements andstagedinstallations.
SpaceSavingDesign
Daikins8ZoneMultiSplitSystemoffersmorethan60% inphysicalspacesavingsandmorethan80%intotal (includingclearances)spacesavingscomparedto conventionaloutdoorunitsprovidingastreamlined solutionforlimitedspaces.
SimplifiedWiring
TheoutdoorunitandBPunitsoperatefromseparate 208/230Vsinglephasepowersupplies.Indoorunitsare poweredfromtheBPunitandwiredasDaikinscurrent 4wiresinglesplitsystemsreducingthewiringsizeand easinginstallation
16
InstallationEase
Longerrefrigerantpipingcapabilitiesoffersmuch moreflexibilityinthechoiceofinstallationpositions fortheindoorunits,andgreatlysimplifiessystem layout.
Split Systems
RMXS
Superiorflexibilitywithmultizone customization
Keyfeaturesinclude: Zonecustomizationwiththeabilitytoconnectfrom 2upto8indoorunitstoasingleoutdoorunit. Increasedenergysavingswithtechnologically advancedcomponentsandinvertertechnology. Superiorflexibilitywiththechoiceofthreeindoor unittypesforidealcomfortdesignedforanydcor. Individualzonecontrolwithstandardwireless controls,optionalwiredcontrols,orthe DaikinENViintelligentthermostat. BranchPortUnit(BPMKS)
TheBranchPort(BP)unitvariestherefrigerantvolumetomeet thecoolingorheatingrequirements.Itseasytodisassemble andmakesrepairsandrecyclingsimple.Choosefrom2zone or3zoneBPunitstomatchthesystemselectiontoindividual requirements. BPMKS Outdoor Units RMXS48LVJU
Model Name Nominal Capacity (Cooling / Heating) SEER / HSPF Btu/h Non Ducted Mixed Ducted Non Ducted Mixed Ducted A A dB(A) RMXS48LVJU 48,000 / 54,000 18.8 / 11.3 16.5 / 10.5 14.1 / 9.6 10.3 / 3.0 9.8 / 2.9 9.3 / 2.7 208/230V - 1 - 60Hz 27.0 30.0 56 / 58 50 - 130% 2 to 8 1 to 3 440 (135) KHRP26A22T 23 115/5 - 75
52-15/16 x 35-7/16 x 12-5/8
BP Units
Model Name Power Supply Power Consumption Running Current Sound Pressure - (Cooling/Heating) Number of Connectable Indoor Units Min. Connection Combination Max. Connection Combination Outdoor Unit Side Liquid Piping Indoor Unit Side Connections Outdoor Unit Side (O.D.) Gas Indoor Unit Side Dimensions (H x W x D) Net Weight
Nominal Conditions: Cooling Mode Indoor: 80 F DB / 67 F WB Outdoor: 95 F DB Pipe Length: 25 ft. Level Difference: 0 ft.
W A dB(A)
EER / COP Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Sound Pressure - (Cooling/Heating) Connection Ratio (Max Capacity for BPMKS Boxes) Number of Connectable Indoor Units Number of Connectable BP Units Total System Piping Length Piping Connection Kit Operating Range (Cooling/Heating) Dimensions (H x W x D) Net Weight
BPMKS048A2U BPMKS049A3U Single phase 60Hz 208/230V 10 10 0.05 0.05 32/32 32/32 1 to 3 1 to 2 7,000 7,000 62,000 48,000 1/4 x 2 1/4 x 3 1/4 x 2 1/4 x 3 5/8 x 2 5/8 x 3 5/8 x 2 5/8 x 3 7-1/16 x 11-9/16 x 13-3/4 18.0 20.0
283.0
Heating Mode Indoor: 70 F DB Outdoor: 47 F DB / 43 F WB Pipe Length: 25 ft. Level Difference: 0 ft.
LongerRefrigerantPiping
Longerrefrigerantpipingcapabilitiesoffersmuchmore flexibilityinthechoiceofinstallationpositionsforthe indoorunits,andgreatlysimplifiessystemlayout.
Piping Requirements
Between outdoor and BP units Maximum allowable length Between BP and indoor units Between BP and indoor unit Allowable height Between outdoor and indoor units Between outdoor and BP units Between BP and BP units Between indoor and indoor units Total piping length Total piping length 1 room length Difference in height
Piping length
x (0.054 kg/m) +
0.036 lb./ft
17
SlimDuctandWallMountedUnits
Compatiblewith2port,3port,4port,and8ZoneMultiSplitSystems
Sliminheightandelegantindesign.
Keyfeaturesinclude:
Extendedrange connectableto 2Port,3Port,4 Port,and8ZoneMultiSplitsystems IncreasedenergysavingswithEcono Modefunction reducingoperatingcurrentandpowerconsumptionby approximately30%duringstartup Achievedesiredtemperaturequicklywithrapidcoolingor heatingviapowerfuloperation Undisturbedcomfortwithindooroperatingsoundlevelsas lowas31dB(A) Sleepcomfortablywithoutasuddenchangeinroom temperaturebyactivatingnightsetmode Enhancedindoorairqualityrealizedwiththemoldproofair filter
Indoor Units - CTXS_HVJU, CTXS_LVJU, and FTXS_LVJU Wall Mounted Units Model Name CTXS07LVJU CTXS09HVJU CTXS12HVJU 2MXS18GVJU 2MXS18GVJU 3MXS24JVJU 3MXS24JVJU 3MXS24JVJU Outdoor Unit Compatibility 4MXS32GVJU 4MXS32GVJU 4MXS32GVJU RMXS48LVJU RMXS48LVJU RMXS48LVJU Airflow-Wet (H/M/L/SL) CFM 332/261/194/145 388/335/283/388/335/283/Airflow-Dry (H/M/L/SL) CFM 350/290/233/219 400/357/314/400/357/314/Sound Pressure - Cooling (H/M/L/SL) dB(A) 38/32/25/22 44/40/35/45/41/36/Sound Pressure - Heating (H/M/L/SL) dB(A) 38/33/28/25 44/39/34/45/40/35/Liquid (O.D.) in. 1/4 1/4 1/4 Gas (O.D.) in. 3/8 3/8 3/8 Piping Connections Condensate Drain in. 5/8 11/16 11/16 Connection (O.D.) Dimensions (H x W x D) in. 11-5/8 x 31-1/2 x 8-7/16 11-7/16 x 31-5/16 x 9-3/8 Net Weight lbs. 20.0 20.0 20.0 Indoor Units - CTXS_HVJU, CTXS_LVJU, and FTXS_LVJU Wall Mounted Units Indoor Units - FDXS_LVJU and CDXS_LVJU Slim Duct Units Model Name FDXS09LVJU FDXS12LVJU 2MXS18GVJU 3MXS24JVJU 3MXS24JVJU 4MXS32GVJU Outdoor Unit Compatibility 4MXS32GVJU RMXS48LVJU RMXS48LVJU External Static Pressure "W.G. 0.12 0.12 Airflow-Wet (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 Airflow-Dry (H/M/L/SL) CFM 305/280/260/235 305/280/260/235 Sound Pressure - Cooling (H/M/L/SL) dB(A) 35/33/31/35/33/31/Sound Pressure - Heating (H/M/L/SL) dB(A) 35/33/31/35/33/31/Liquid (O.D.) in. 1/4 1/4 Piping Connections Gas (O.D.) in. 3/8 3/8 Condensate Drain in. 25/32 25/32 Dimensions (H x W x D) in. 7-7/8 x 27-9/16 x 24-7/16
FTXS15LVJU 3MXS24JVJU 4MXS32GVJU RMXS48LVJU 568/477/385/360 593/505/417/371 45/40/35/32 43/38/33/30 1/4 1/2 5/8 31.0 CDXS15LVJU 3MXS24JVJU 4MXS32GVJU RMXS48LVJU 0.16 424/388/353/297 424/388/353/297 37/35/33/31 37/35/33/31 1/4 1/2 25/32
FTXS18LVJU 3MXS24JVJU 4MXS32GVJU RMXS48LVJU 583/484/385/360 625/526/431/399 46/41/36/33 45/40/35/32 1/4 1/2 5/8 13-3/8 x 41-5/8 x 9-3/4 31.0 CDXS18LVJU 3MXS24JVJU 4MXS32GVJU RMXS48LVJU
FTXS24LVJU RMXS48LVJU 643/494/350/328 699/572/445/403 51/44/37/34 48/42/37/34 1/4 5/8 5/8 31.0 CDXS24LVJU RMXS48LVJU
0.16 0.16 424/388/353/297 424/388/353/297 424/388/353/297 424/388/353/297 37/35/33/31 37/35/33/31 37/35/33/31 37/35/33/31 1/4 1/4 1/2 1/2 25/32 25/32 7-7/8x35-7/16x24-7/16
18
2X2CeilingCassette
Compatiblewith2port,3port,4port,and8Zone MultiSplitSystems
Split Systems
CustomizableComfortinaCompactdesign.
Keyfeaturesinclude: Efficientairflowdistributionwithverticalautoswing Customizablecomfortwith5freelyselectedairflow patternsbetween0and40degrees Comfortwithoutadisturbancewithwhisperquiet operation Draughtfreeoperationwithhorizontalairdischarge Seamlessarchitecturaldesignwiththeabilitytosit flushintoceilings Flexibledesignwithcapacityrangesfrom9,000Btu/h to18,000Btu/h
38.5
12,000 15,000 14,000 17,500 Single phase 60Hz 208/230V 353/230 424/283 38/29 42/31 38/29 42/31 1/4 1/4 3/8 1/2 1-1/32 1-1/32 11-1/4 x 22-5/8 x 22-5/8 2-1/4 x 27-5/8 x 27-5/8 38.5 38.5
38.5
InstallationSpace
DesignFlexibility
Fourwaydirectionalairflowandeasyadjustments forcornerorcorridorinstallation.
Height=11.6 ormore
(Note)Leave77/8ormorespacewheremarkedwiththe*, onsideswheretheairoutletisclosed.
19
SplitSystemsIndividualZoneControls
WithDaikinssuperintelligent,userfriendlysystemcontrollers,youcancreateAbsoluteComfort quicklyandeasily.Theiradvancedfunctionalityandeasytoreadliquidcrystaldisplays(LCDs)allow youtoorchestrateandmonitortemperature,time,airflowvolumeandmoreacrossyourentire systematthetouchofbutton. WirelessRemoteController ARC452
Thisremotecontrollerputssuperiorcomfortatyourfingertips. Frequentlyusedbuttonsareinstantlyaccessiblewhileotherbuttons areunderthecoveroftheremote.Alargeliquidcrystaldisplaypanel makesiteasytoreadthesettingsandtheOn/Offbuttonhasaraised dotsothatyoucanfeelitinthedark.
WiredRemoteController BRC944B2(Option)
ThiswiredremotecontrolleroptionisforSingleSplit,MultiSplit, 8ZoneMultiSplit,andSkyAirFTXSsystemindoorunitswhich ARC452wirelessremotecontrollerisapplicable.Thecontroller featureson/off,operationmode(Cool,Heat,Dry,Auto),setpoint adjustment,fanspeedadjustment,airflowdirectionadjustment, onetimedailytimer. Fahrenheit/Celsiusisselectable.
QuaternityWirelessRemoteController ARC447A3
Thisinfraredremotecontrollerdisplaysanabundanceoffunctions suchasambienttemperatureandroomtemperature tosetyourQuaternitySystemexactlytoyourliking.
WirelessRemoteController BRC7E830(Option)
Thisinfraredremotecontroller,forusewith2X2CeilingCassette FFQindoorunit,features fanspeedcontrol,temperaturesettings, andprogramdryoperation.
NavigationRemoteController BRC1E72(Option)
Thisremotecontrolleriscompatiblewiththenew2X2Ceiling CassetteFFQindoorunit.Theconfigurabledisplayoffers3options withanadvanceddisplaygreatforresidentialapplicationsanda simplifieddisplayidealforapplicationssuchashotelswantingto onlyprovidethenecessarybuttonstousersforcomfortwithout confusion.
20
DaikinENViIntelligentThermostat
DACATS11
Split Systems
The Daikin ENVi Intelligent Thermostat is the newest addition to Daikins residential controls offering. The wall mounted controller features a backlit LCD display and easy to understand menu items to be used where the BRC944 wired remote controller is applicable. Canbeusedwith: SingleSplitSystem MultiSplitSystem(2to8ports) SkyAirFTXSIndoorUnits Applicableindoorunitmodels: FTXS,FTXN(09/12requiresKRP980B1 interfaceadapter),CTXS,FDXSandCDXS Function
Cool,Heat,andAutomodeswithdualsetpoints. Weeklyscheduling. Setbackcontrol. Optimumstart. Hold,Quicksave,andVacationsettings. FanOn/Auto,Fanspeed,andLouverdirection. Errorcodewithplaintextexplanation. WiFi enabled. DealerWebPortal. Auxheatercontrol.
WiFi enabled!
AccessiblethroughPCweb,Smartphone/Tablet DealerWebPortal(AlertEmailandTrendGraph).
Display
Standarddisplay. Roomtemperature/relativehumiditydisplay. Outdoortemperatureandweatherforecast.
Other
Backlit Fahrenheit/Celsiusselectable. Currentoperationstatus. Roomtemperaturesensor.
www.DaikinENVi.com
21
AirtoWaterHeatPump
SystemAttributes
DaikinAlthermaisapowerfulsolutionwithkeybenefitsfortheenvironment,enhancedefficiency anduseindiverseapplications.
Environment
1. 2. 3. 4.
Efficiency
1. 2. 3.
Application
1. 2. 3.
22
Components
DaikinAlthermaconsistsof5componentswhichworktogethertoprovidetheidealcomfortandwatertemperature. 1. OutdoorUnit:Anefficientuseofenergyfromtheair Utilizinganaturalsourceofenergy,theoutdoorunitextractsheatfromtheoutsideairandtransfersitthroughrefrigerant pipingtosupplyheating.Installedasasplitsystemconsistingofanoutdoorcompressorunitandhydrobox containingthe hydronic componentsoramonobloc systemwithasingleoutdoorunitcombiningboththecompressorandhydronic components,DaikinAlthermadeliversanenergyefficientsystem,compactandeasilyinstalled. 2. Hydrobox:Aboilerfromaheatpumpsource Thehydrobox heatsthewaterthatcirculatesthroughlowtemperatureradiators,floorheatingsystemsorfancoilunitsand providesdomestichotwater.Withoptionalcooling,thehydrobox hastheabilitytoreversethecycletoprovidechilled water. 3. DomesticHotWaterTank:Forlowenergyconsumption Availableintwosizes,thedomestichotwatertankprovideswarmwaterprimarilyfromthethermalenergyfromthe outsideair.Withspeciallyplacedsystemcomponents,aheatexchangerconnectedtotheheatpumpalongwitha supplementalelectricalheatingelementtoboosthotwatertemperatureforanyadditionalwaterheatingneeds,warm waterisalwaysprovidedwithmaximumenergyefficiency. 4. SolarConnectionKit: Averagedoverayear,thesundelivershalfoftheenergyneededtobringdomestichotwateruptothedesiredtemperature forfree.ByconnectingasolarboilertotheDaikinAlthermasystem,raysaretransferredintoheatandstoredinawater storagetank. 5. RoomThermostat:Forconvenienttemperatureregulation Withthewiredroomthermostat,theidealtemperaturecanbeconvenientlyregulatedeasilyandquickly.
DaikinAltherma
Capacity Application Configuration R-410A Refrigerant Piping H2O Piping Installers Advantages Connectable Heating Emitters
Combinable With
Nominal 1.5 Ton to 4.5 Ton Heating and (optional) cooling Domestic hot water Outdoor (compressor) unit Indoor (hydronic parts) unit Between outdoor unit and indoor unit Between indoor unit and indoor heating applicances No extra insulation of H2O piping required to protect from freezing up Under floor heating Low temperature radiators Fan coil units Heat pump convector Domestic hot water storage tank Solar thermal connection for hot water production Third party thermostats
Nominal 3.0 Ton to 4.5 Ton Heating and (optional) cooling Domestic hot water Outdoor unit (compressor and hydronic parts combined) Inside outdoor unit Between outdoor unit and heating terminal units Only H2O piping needed to install the system Under floor heating Low temperature radiators Fan coil units Heat pump convector Domestic hot water storage tank Solar thermal connection for hot water production Third party thermostats
23
SplitSystemSpecifications
Split System
Indoor Unit Dimensions HxWxD Leaving Water Heating Temp Range Cooling Water Volume Water Flow Rate Min./Max Back Up Heater Power Supply Single Stage Back Capacity Up Heater MCA (BA3VJU) MOP Capacity Two Stage Back Up MCA Heater (BA6VJU) MOP Nominal capacity COP EER Dimensions (Net) Operation range Heating Cooling in. F (C) F (C) gal. GPM kW A A kW A A Btu/h Btu/h EKHB_030BA_VJU EKHB_054BA_VJU 36 5/16 x 19 3/4 x 14 7/32 36 5/16 x 19 3/4 x 14 7/32 (59) 77 - 131* ((15) 25 - 55) (59) 77 - 131* ((15) 25 - 55) 41 - 71.6 (5 - 22) (If using EKHBX030) 41 - 71.6 (5 - 22) (If using EKHBX054) 0.18 0.26 3.17/11.09 4.23/15.32 208-230V/1Ph/60Hz 208-230V/1Ph/60Hz 3kW 3kW 14.3 A 14.3 A 20 A 20 A 6kW 6kW 28.6 A 28.6 A 30 A 30 A ERLQ018BAVJU ERLQ024BAVJU ERLQ030BAVJU ERLQ036BAVJU ERLQ048BAVJU ERLQ054BAVJU 38,200 47,800 54,600 19,620 23,340 28,760 47,600 59,100 60,600 24,570 27,840 28,560 4.55 4.42 4.18 4.25 4.12 3.81 12.4 10.2 8.9 10.41 9.7 9.33 46 1/6 x 35 7/16 x 12 5/8 28-9/10 x 32-1/2 x 11-8/10 -4 - 95 (-20 - 35) -4 - 77 (-20 - 25) 50 - 114.8 (10 - 46) 50 - 110 (10 - 43) -4 - 109.4 (-20 - 43) -4 - 110 (-20 - 43)* 16.4 16.4 16.4 10 10 10 246 246 246 98 98 98 66 66 66 98.4 98.4 98.4 208-230V/1Ph/60Hz 18 18 20 30
ERLQ018,024,030BA
ERLQ036,048,054BA
Measuring conditions: Heating Ta DB/WB 44.6F/42.8F (7/6C) - LWC 95F (35C) (DT=9F (5C) - Cooling Ta 95F (35C) - LWE 64.4F (18C) (DT=9F (5C) * Booster heater operation from 95F (35C) onwards (1) These conditions are based on under floor heating/cooling application
EFWT___A
Heating Btu/h 25,000 Cooling (T) Btu/h 28,600 Cooling (S) Btu/h 22,400 Dimensions HxWxD in. 40x20x20 Nominal Air Flow Rate CFM 800 Heating F (C) EWT Range Cooling F (C) Nominal Water Flow Rate gpm 4.5 Nominal Pressure Drop Ft Hd 5.5 Power AEVLU MCA 6 (ECM) MOP 15 Power APVLU MCA 3.8 (PSC) Electrical MOP 15 Power AEVJU MCA 3 (ECM) MOP 15 E-Heat 5, 10kW
Notes: 1. Cooling Capacity is based on 50F Entering Water Temp and 80F DB/67F WB Entering Air Conditions. 2. Heating Capacity is based on 110F Entering Water Temp and 70F DB Entering Air Conditions. 3. Refer to detailed capacity tables for further information pertaining to the entire entering water temperature range and for flow rates and pressure drop. 4. Refer to engineering data book for further information on electric heat options. 5. Std efficiency models with PSC motor are available on request.
EKHWS___BA3
MonoBlocSpecifications
MonoBloc System
Outdoor Unit
Model Number Nominal capacity COP EER Operation range Heating F (C) Cooling F (C) Domestic water F (C) With bottom plate heater Heating Btu/hr Cooling Btu/hr EDLQ036BA 38,200 4.32 -
Heating Only
EDLQ048BA EDLQ054BA 47,700 54,600 4.2 4.07 5 - 95 (1) (-15 - 35) 5 - 95 (1)(2) (-15 - 35) 208-230V/1Ph/60Hz 28.6 30 55 27/32 x 56 1/2 x 15 1/32 N/A 0.27 4.23 / 15.32 8.48 N/A 10.59 N/A 6 2 28.6 30 208-230V / 1 / 60Hz 12.13 N/A 8.48 9.72
EDLQ036,048,054BA EBLQ036,048,054BA
Power supply MCA A MOP A Dimensions (Net) HxWxD in. Leaving Water Cooling F (C) Temperature Range Water volume gal. Water flow rate GPM Water side Heat Min./Max exchanger Water flow rate Heat GPM Nom. Cool GPM Capacity kW Capacity Steps Factory mounted MOP Back Up Heater MCA Power supply
DaikinAltherma
Measuring conditions: Heating Ta DB/WB 44.6F/42.8F (7/6C) - LWC 95F (35C) - Cooling Ta 95F (35C) - LWE 64.4F (18C) (1) E(D/B)L* models can reach -4F (-20C) but without capacity guarantee (2) Booster heater operation from 95F (35C) onwards (3) These conditions are based on under floor heating/cooling application (4) For further information pertaining to the hydronic specs of the MonoBloc system, refer to the engineering databook
Pump
Water Circuit Ambient Temperature Power Supply Power Supply Intake Dimensions (Net) H x W x D
in.
Option List
Model Number
Condensate Kit Digital I/O PCB EKHBDP EKRP1HBAAU DACA-DHWRA-1 DACA-DHWTA-1 DACA-THXA-1 DACA-3WVTA-1 DACA-3WVTH-1 BSP to NPT Connection Adaptors DACA-HBA-1 DACA-HBA-2 DACA-HBA-3 DACA-MP-1 Wall Mounting Bracket for Condensing Unit 3rd Party DHW Tank Connection Kit DACA-WB-3 DACA-DHW-KIT-1
Notes
For Cooling Mode Applications Unit On/Off Alarm On/Off Solar Input DHW Recirculation Loop 1/2" DHW Tank Inlet/Outlet 3/4" DHW He-Ex 1" 3-Way Valave 1-1/4" 3-Way Valve 1" EKHB_054 Hydrobox Inlet/Outlet 1-1/4" EKHB_030 Hydrobox Inlet/Outlet 1" EDLQ/EBLQ Inlet/Outlet 1-1/4" DHW Tank Plug 3/4" Unit Weight - Up to 500 lbs. For Tanks up to 119G
Currently there is no appropriate U.S. recognized testing and rating standard for technology that is of Air to Water design and can solve Hydronic Heating, Domestic Hot Water and Cooling requirements in a single packaged solution. As such, the U.S. Department of Energy (DOE) has issued Daikin with Waivers (Case number: CAC-024, as published from page no. 34,731 in the DOE Federal Register on June 18th, 2010, and Case number CAC028 as published from page no. 11,438 in the DOE Federal Register on March 2nd, 2011) and assigned an "Alternate Test Procedure" detailing testing requirements to establish full load COP and EER values and provision for calculating the Seasonal Performance Factor (SPF).
25
SkyAirSystems
SkyAiristheultimateductedandductfreesolutionforlightcommercialandresidentialwholehouse applications.Rangingfrom18,000Btu/hto42,000Btu/h,theseinnovativesystemsprovideenergy efficiency,technologicalreliabilityandinstallationflexibility.
Keyfeaturesandbenefitsinclude: DC fanmotorimprovesefficiencycomparedtoconventionalAC motors. Aerospiralfanandgrilleminimizesturbulenceandincreases soundreduction. Reluctancebrushless DCcompressorincreasesefficiency. Swingcompressorwithfrictionreductionandquieterrotationor scrollcompressorwithrobustandlow sounddesignprovides maximumdurability. Longpipinglengthsupto230ft.allowlayoutflexibility. Anticorrosiontreatmentontheoutdoorheatexchanger increasesdurability.
FBQ
FCQ
FHQ
FTQ
26
SkyAirFeatures
SkyAir Type FTXS Cool OnlyandHeatPump FHQ FAQ FBQ FCQ FTQ Models PulseAmplitudeModulation ComfortableAirflow PowerAirflowDualFlaps WideAngleLouvers VerticalAutoSwing(upanddown) HorizontalAutoSwing(leftandright) 3DAirflow ComfortableMode IndoorUnitQuietOperation ComfortControl OutdoorUnitQuietOperation IntelligentEye AutomaticOperation(heat pumponly) ProgramDryFunction AutoFanSpeed HotStart(heatpumponly) Healthy MoldProofAirFilter TitaniumApatitePhotocatalytic AirPurifyingFunction WipeCleanFlatPanel StandbyElectricitySaving EconoMode Lifestyle PowerfulOperation RemoteControllerwithBacklitDisplay LCDWirelessRemoteControl IndoorUnitOn/OffTimer Timers 24HourOn/OffTimer WeeklyTimer NightSetMode WorryFree AutoRestartAfterPowerFailure SelfDiagnosiswithDigitalDisplay AnticorrosionTreatmentofOutdoorHeatExchangerFin StandardFeature Optional Feature
SkyAir
With BRC1E72Controller
27
WallMountedUnit
RZQ_PVJU9 RZR_PVJU
FAQ_PVJU
BRC1E72 (Option)
BRC7E818 (Option)
Sleekindesignwithcomfortcontrolfeatures.
Keyfeaturesinclude: EnergyefficiencyuptoSEER18.6andHSPF9.1 Wideanglelouversdistributecomfortableairflow Autoswingfunctionensuresefficientairdistribution Frontpanelcanberemovedforeasycleaning Quietoperationaslowas37dB(A) Optionalwirelesscontroller Optionalwiredcontroller Optionalcondensatepump
System Performance
Model Name Cooling Capacity (Rated) Heating Capacity (Rated) SEER EER HSPF* Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Power Consumption - Cooling Power Consumption - Heating* Indoor (Cooling Only and Heat Pump) Outdoor (Cooling Only) Outdoor (Heat Pump) Btu/h Btu/h FAQ18PVJU RZR18PVJU RZQ18PVJU9 18,000 20,000 18.6 12.7 8.7 208-230V/1/60 16.5 20.0 1,420 1,870 FAQ18PVJU n/a 500/400 43/37 43/37 3/8 5/8 11/16 11-3/8 x 41-3/8 x 9 31 31 16.5 20.0 2,350 3,300 FAQ24PVJU n/a 635/470 43/37 43/37 3/8 5/8 11/16 FAQ24PVJU RZR24PVJU RZQ24PVJU9 24,000 26,000 17.6 10.2 9.1
V/ph/Hz A A W W
28
WallMountedUnit
BRC944B2
(Option)
RXS_LVJU RKS_LVJU
ARC452 FTXS_LVJU
(Option)
Sophisticatedindesignwithenergysaving features.
Keyfeaturesinclude: EnergyefficiencyuptoSEER19.3 Intelligenteyeadjustsoperationmodedependingon occupancy,maximizingenergysavings Wideanglelouversand3Dairflowprovide comfortableandefficientairdistribution Titaniumapatitephotocatalytic airpurifyingfilter providescleaner,healthierair Standbyelectricitysavingfeaturereducesenergy consumptionbyupto90%whenthesystemisnotin use
UltraLowAmbientkitforRKS_LVJUwillextendworryfree operation withfactorytestedandapprovedcoolingoperationdownto40F/40C.
System Performance
Model Name Cooling Capacity (Rated) Cooling Capacity (Min Max) Heating Capacity (Rated)* Heating Capacity (Min Max)* SEER / EER HSPF* Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Power Consumption - Cooling Power Consumption - Heating* Indoor (Cooling Only and Heat Pump) Outdoor (Cooling Only) Outdoor (Heat Pump) Btu/h Btu/h Btu/h Btu/h V/ph/Hz A A W W FTXS30LVJU RKS30LVJU RXS30LVJU 30,000 10,200 - 30,000 34,800 10,200 - 34,800 19.3 / 10.71 8.3 208-230V/1/60 19.5 20.0 2,800 3,900 19.5 20.0 4,300 4,200 FTXS36LVJU RKS36LVJU RXS36LVJU 36,000 10,200 - 36,000 38,000 10,200 - 38,000 17.9 / 8.37 8.3
SkyAir
Ultra Low Ambient kit contains a code heater, crank case heater, and printed circuit board and can be installed on the following models only:
Kit Model Outdoor Units 2F018535-1 RKS30LVJU 2F018535-2 RXS36LVJU Optionaloutdoorunitwindbaffle,KPW5E112,isrequiredandsoldseparately. OptionalCodeHeater: 208/230V60Hz7WOptionalCrankCaseHeater:208/230V60Hz18W Indoor Units FTXS30LVJU FTXS36LVJU Tons 2.5 3.0
29
DCDuctConcealed
RZQ_PVJU(9) RZR_PVJU
FBQ_PVJU
BRC1E72 (Option)
BRC4C82 (Option)
Powerfulsysteminacompactdesign.
Keyfeaturesinclude: Mediumexternalstaticpressure(ESP)capabilities offerupto0.8W.G. DCfanmotorprovidesimprovedefficiency Threeuserselectedfanspeedsavailableplusfan Autologic Builtincondensatepump Bottomaccessforeasyservice Lowprofiledesignatlessthan12high Optionalwiredcontroller
System Performance
Model Name
FBQ18PVJU
RZR18PVJU RZQ18PVJU9 18,000 20,000 17.5 14.1 10.6 16.5 20 1,280 1,540 FBQ18PVJU 635/582/529 41/39/37 41/39/37 1/4 ** 1/2 ** 1-1/4 80 RZR18PVJU RZQ18PVJU9 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98
FBQ24PVJU
FBQ30PVJU
FBQ36PVJU
RZR36PVJU RZQ36PVJU9 36,000 40,000 17.5 11.2 9.1 27 30 3,210 3,350 FBQ36PVJU 1130/953/812
FBQ42PVJU
RZR42PVJU RZQ42PVJU9 42,000 47,000 16.0 10.2 8.8 27 30 4,120 4,050 FBQ42PVJU 1377/1165/988
Outdoor (Cooling Only) Outdoor (Heat Pump) Cooling Capacity (Rated) Heating Capacity (Rated) SEER EER HSPF* Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Power Consumption - Cooling Power Consumption - Heating*
V/ph/Hz A A W W
RZR24PVJU RZR30PVJU RZQ24PVJU9 RZQ30PVJU 24,000 30,000 27,000 34,000 16.5 16.0 12.0 10.5 10.5 9.2 208-230/1/60 16.5 16.5 20 20 2,000 2,860 2,330 3,020 FBQ24PVJU FBQ30PVJU 688/618/565 882/794/706 Standard 0.40 (0.80 - 0.20) 42/40/38 43/41/39 42/40/38 43/41/39 3/8 3/8 5/8 5/8 1-1/4 1-1/4 11-13/16 x 39-3/8 x 27-9/16 80 80 RZR24PVJU RZQ24PVJU9 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 30-5/16 x 35-7/16 x 12-5/8 150 RZR30PVJU RZQ30PVJU 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 150
43/41/39 44/42/40 43/41/39 44/42/40 3/8 3/8 5/8 5/8 1-1/4 1-1/4 11-13/16 x 55-1/8 x 27-9/16 102 102 RZR36PVJU RZQ36PVJU9 58/58 23 - 115 0 - 115 RZR42PVJU RZQ42PVJU9 58/58 23 - 115 0 - 115
150
**use a 3/8 x 5/8 line set and reduce at the indoor unit connections. Refer to Technical Bulletin #001-13.
MERV 13 Filter Kit Option contains a MERV 13 filter, adapter frame and easy to follow installation instructions and can be installed on the following models only: Kit Model Indoor Units DACA-FXMQ12-13-1K FXMQ07-12PVJU DACA-FXMQ30-13-1K FXMQ18-30PVJU DACA-FXMQ48-13-1K FXMQ36-48PVJU
Indoor Units
FBQ18-30PVJU FBQ36-42PVJU
30
RoundFlowCassette
RZQ_PVJU(9) RZR_PVJU
FCQ_PAVJU
BRC1E72 (Option)
Customizablecomfortidealforopenplanapplications. Keyfeaturesinclude: 23configurableairflowpatternsensureidealair distributionformaximumcomfortandsavings 360 airflowreducesdraft Lowerairvelocitiesprovidebetterairflowdistribution Stainresistantdecorationpanelallowsforeasy cleaning Condensatepumpprovidedasstandard Outsideairintegrationpossible Optionalwiredcontroller
System Performance
Model Name Indoor (Cooling Only and Heat Pump) Outdoor (Cooling Only) Outdoor (Heat Pump) Btu/h Btu/h FCQ18PAVJU RZR18PVJU RZQ18PVJU9 18,000 20,000 17.2 13.9 10.1 16.5 20.0 1,380 1,460 FCQ18PAVJU 560/470/390 32/30/27 32/30/27 1/4 ** 1/2 ** 1-1/4 43.0 RZR18PVJU RZQ18PVJU9 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 150 FCQ24PAVJU RZR24PVJU RZQ24PVJU9 24,000 27,000 16.8 12.0 9.7 16.5 20.0 2,000 2,080 FCQ24PAVJU 780/620/470 36/32/28 36/32/28 3/8 5/8 1-1/4 9-11/16 x 33-1/16 x 33-1/16 48.5 RZR24PVJU RZQ24PVJU9 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 30-5/16 x 35-7/16 x 12-5/8 150 FCQ30PAVJU RZR30PVJU RZQ30PVJU 30,000 34,000 15.8 10.2 9.7 208-230/1/60 16.5 20.0 3,230 2,930 FCQ30PAVJU 830/670/530 38/35/31 38/35/31 3/8 5/8 1-1/4 48.5 RZR30PVJU RZQ30PVJU 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 150 FCQ36PAVJU RZR36PVJU RZQ36PVJU9 36,000 40,000 17.5 11.2 8.4 27.0 30.0 3,160 3,260 FCQ42PAVJU RZR42PVJU RZQ42PVJU9 42,000 47,000 16 10.2 8.5 27.0 30.0 4,080 4,050
Cooling Capacity (Rated) Heating Capacity (Rated) SEER EER HSPF* Power Supply Minimum Circuit Amps Maximum Overcurrent Protection Power Consumption - Cooling Power Consumption - Heating*
SkyAir
V/ph/Hz A A W W
FCQ36PAVJU FCQ42PAVJU 1180/910/700 1220/970/790 44/38/32 45/40/34 44/38/32 45/40/34 3/8 3/8 5/8 5/8 1-1/4 1-1/4 11-5/16 x 33-1/16 x 33-1/16 55.0 55.0 RZR36PVJU RZQ36PVJU9 58/58 23 - 115 0 - 115 RZR42PVJU RZQ42PVJU9 58/58 23 - 115 0 - 115
**use a 3/8 x 5/8 line set and reduce at the indoor unit connections. Refer to Technical Bulletin #001-13.
MERV 13 Filter Kit Option contains a MERV 13 filter and easy to follow installation instructions and can be installed on the following models only:
Kit Model DACA-FQP13-1K Indoor Units FCQ18-42PAVJU
31
CeilingSuspended
RZQ_PVJU(9) RZR_PVJU
FHQ_PVJU FHQ_MVJU
BRC1E72 (Option)
BRC7E83 (Option)
Aslimsolutionforopenorstructuredceilings.
Keyfeaturesinclude: Sliminheightatlessthan8 Autoswingcapabilitywith100 airflowpattern distributescomfortableairflow Innovativestreamfantechnologykeepssound pressurelevelslow Lateralservicingspaceallowsinstallationincorners, narrowspaces,walls,andceilings Flatpaneldesignmakescleaningsimple Concealedpiping Optionalwiredcontroller Optionalcondensatepump
System Performance
Indoor (Cooling Only and Heat Pump) Outdoor (Cooling Only) Outdoor (Heat Pump) Cooling Capacity (Rated) Btu/h Heating Capacity (Rated) Btu/h SEER EER HSPF* Power Supply V/ph/Hz Minimum Circuit Amps A Maximum Overcurrent Protection A Power Consumption - Cooling W Power Consumption - Heating* W Model Name FHQ18PVJU RZR18PVJU RZQ18PVJU9 18,000 20,000 18.0 14.0 11.1 16.5 20 1,290 1,510 FHQ18PVJU 790/670 45/45/ 3/8 5/8 1 90 RZR18PVJU RZQ18PVJU9 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 150 FHQ24PVJU RZR24PVJU RZQ24PVJU9 24,000 27,000 18.1 12.6 10.0 16.5 20 1,900 2,200 FHQ24PVJU 790/670 45/45/ 3/8 5/8 1 90 RZR24PVJU RZQ24PVJU9 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 30-5/16 x 35-7/16 x 12-5/8 150 FHQ30PVJU RZR30PVJU RZQ30PVJU 30,000 34,000 17.2 10.5 8.4 208-230/1/60 27 30 2,860 3,690 FHQ36MVJU RZR36PVJU RZQ36PVJU9 36,000 37,500 14.0 10.2 8.1 27 30 3,530 3,660 FHQ42MVJU RZR42PVJU RZQ42PVJU9 40,500 39,500 13.8 9.5 8.2 27 30 4,260 3,990 FHQ42MVJU 850/700 47/47/ 3/8 5/8 1 90 RZR42PVJU RZQ42PVJU9 58/58 23 - 115 0 - 115
FHQ30PVJU FHQ36MVJU 790/670 830/670 45/46/45/46/ 3/8 3/8 5/8 5/8 1 1 7-11/16 x 62-5/8 x 26-3/4 90 90 RZR30PVJU RZQ30PVJU 49/49 23 - 115 0 - 115 0 - 77 0 - 60 164 98 150 RZR36PVJU RZQ36PVJU9 58/58 23 - 115 0 - 115
32
InverterDucted
RZQ_PVJU9
FTQ_PBVJU
BRC1E72 (Option)
BRC4C82 (Option)
Anintelligentalternativetotraditionalunitary systems.
Keyfeaturesinclude: Upfloworhorizontalrightconfigurationsforthe indoorunit EnergyefficiencyuptoSEER20.0 Highheatingcapacityatlowambienttemperaturesas lowas0Fwithnoelectricalheat Fieldinstalledelectricheateroptionsavailablefrom3 kWto15kW(electricheaterconnectionkitpartno. KER26A60requiredforelectricheatintegration) Lowoutdoorunitsoundlevels(aslowas49dB(A)) comparedtotraditionalsystems(73dB(A))
CombinationofFTQ18/24/30/36PBVJUwith RZQ18/24/30/36PVJU9qualifyfortheEnergyTax ExtendersofTheAmericanTaxpayersReliefActof2012.
System Performance
Model Name Indoor Outdoor Btu/h Btu/h Cooling Capacity (Rated) Heating Capacity (Rated) SEER EER HSPF COP Power Supply Minimum Circuit Amps Maximum Overcurrent Protection FTQ18PBVJU RZQ18PVJU9 18,000 20,000 20.0 14.5 12.0 4.0 1.5 20.0 FTQ18PBVJU in. W.G. CFM in. in. in. in. lbs. FTQ24PBVJU FTQ30PBVJU Up to 0.50 1,000/850/700 3/8 5/8 1 192.0 RZQ30PVJU9 49/49 23 - 115 0 - 77 0 - 115 0 - 60 RZQ36PVJU9 58/58 23 - 115 0 - 77 0 - 115 0 - 60 230.0 164.0 52-15/16 x 35-7/16 x 12-5/8 283.0 FTQ24PBVJU RZQ24PVJU9 24,000 27,000 19.0 13.5 11.5 3.8 1.6 FTQ30PBVJU RZQ30PVJU9 30,000 34,000 19.5 13.5 10.0 3.7 208-230/1/60 2.3 FTQ36PBVJU RZQ36PVJU9 36,000 40,000 18.0 12.5 9.5 3.6 2.8 30.0 FTQ36PBVJU 1,200/1,020/840 3/8 5/8 1 58-1/4 x 22 x 26 FTQ42PBVJU RZQ42PVJU9 40,000 47,000 17.0 12.0 9.0 3.2 3.6
SkyAir
V/ph/Hz A A
600/510/420 800/680/560 3/8 3/8 5/8 5/8 1 1 48-1/8 x 22 x 26 150.0 RZQ18PVJU9 49/49 23 - 115 0 - 77 0 - 115 0 - 60 RZQ24PVJU9 49/49 23 - 115 0 - 77 0 - 115 0 - 60
Operating Range - Heating Max. Piping Length Max. Piping Height Dimensions (H x W x D) Net Weight
HKR-10C X
HKR-15C X X X X * 33
Electric heater option with heat pump is allowed *Acceptable for 2-step control
34
SkyAirControls
Individual Zone Controllers
Navigation Wired R/C BRC1E72 Wireless R/C BRC7E818 BRC4C82 BRC7E83 Wired R/C BRC944B2 Wireless R/C For FTXS ARC452 Model
Operation
Backlit LCD Display F/C Selector Intuitive Configuration Menu Room Temperature Display Temperature Sensor Included Clock Display 12/24 Hour 24 Hour 24 Hour English/French/Spanish Start/Stop Operation Mode Setpoint Auto-changeover Independent Cooling and Heating Setpoints Setpoint Range Limitation Setpoint Minimum Dead-band Setpoint Range Setback Unit Off Permit/Prohibit Selection Fan Speed Airflow Direction Status Malfunction Flashing Malfunction Content Filter Sign Operation Mode Setpoint Permit/Prohibit Selection Fan Speed Airflow Direction Weekly Actions Per Day Scheduling Pattern Auto On/Off Timer Error History Backup During Power Loss Field Setting Mode 7-Day Time Clock Setback Function Auto Restart
12/24 Hour Dual/Single Heat Pump 0-8F, Default 2F 60 to 90F (Independent Cool/Heat) Range 40-95F (Out of Setpoint Range) Access Level + Individual Button Prohibit 5 (Independent Cool/Heat setpoints) 7-Day, 5+2, 5+1+1, 1 (EveryDay) 48 Hours
User Friendly
24 Hour
60 to 90F
64 to 90F
64 to 90F
4 7-Day
SkyAir
Scheduling
Monitoring
35
VRVSystems
VRVsystemsprovideadvancedsolutionsforalmostanylargeresidentialtocommercial application.Availableinaircooledorwatercooledsolutionsupto30tonsinheat pumpsystemsand28tonsinheatrecoverysystems,VRVIIIprovidesadvancedheating andcoolingoptionswithindividualzonecontrolforbothopenplanandtightly groupedapplications.
FeaturesofVRV: Energyefficient,invertervariablespeedcompressors Individualzonecontrol upto62zonesonasinglepiping network Longpiping Largecapacitywithmodularsystemscombinations Quietoperationwithindoorunitsoundlevelsaslowas25 dB(A) Highlevelcontrol(BACnet,LonWorks,IntelligentManager, IntelligentTouchController) Superiorheatingperformance Absolutecomfort
Idealforresidentialandlight commercialapplications, VRVIIISaircooledsystemsare availablein3and4tonsand canoperateupto8fancoil units.Thesesystemsprovide individualzonecontroland advancedzoningcapabilitiesin aninnovativespacesaving design.
Designedforlargecommercial applications,VRVIIIsystemsare availableinupto30tonsin heatpumpor28tonsinheat recovery.Withtheabilityto operateupto62indoorfancoil unitsonasinglesystem,the VRVIIIprovidesexcellentpart loadperformanceinamodular centralizedsystem.
Greatforbothlightandlarge commercialapplications,the VRVWIIIprovidescoldclimate capabilitiesinalightweight, compactdesign.Availableasa unifiedheatpumporheat recoverysolutions,VRVWIII offersanenergysaving alternativetocentralized systems.
VRV
37
LightCommercial
Ahighlyefficientsolutionforsmallcommercial applications,theVRVIIISprovidescoolingand heatingforupto8zones.With11different indoorunitoptionstochoosefrom,systemscan bepairedwithamixofductedandductfree indoorunitsforacustomizablesystemfor almostanyapplication. Designedforflexibilityandversatility,theVRVIII Ssystemprovideslongpipinglengths(upto 1000ft.actualpipinglengthoneway),makingit anaccommodatingandspacesavingsolutionfor almostanyfloorlayout.
Certified Performance Data
Outdoor Unit Indoor Units Combination Non-Ducted Indoor Units Ducted Indoor Units Mixed Ducted and Non-Ducted Indoor Units Non-Ducted Indoor Units Ducted Indoor Units Mixed Ducted and Non-Ducted Indoor Units Nominal Cooling Capacity (Btu/h) 36,000 36,000 36,000 47,500 47,500 47,500 EER 95 F 11.50 9.90 10.70 9.00 9.00 9.00
Residential
VRVIIISprovidesanintelligentalternativefor bothrenovationsandnewconstructionhomes. Connectinguptoeightzonesonasingle outdoorunit,thissystemprovidesdesign flexibilityinacompact,spacesavingdesign. Indoorunitsofferspeedcontrolwithquiet operatingsoundlevelsaslowas28dB(A)with outdoorunitshavingbuiltinnoisereducing features.Activatethenightsetmodefeature andoperatingsoundsprogressivelyreduce3 dB(A)forquieterandgentlercoolerorheating.
RXYMQ36PVJU
Nominal Heating Capacity (Btu/h) 42,000 42,000 42,000 52,500 52,500 52,500
Low Heating Capacity (Btu/h) 26,000 29,500 27,750 33,000 36,500 34,750
RXYMQ48PVJU
38
VRVtechnologyinacompactsize.
Features,the7SforSuccess: Singlephasetechnology Smallercapacityforprecisetemperaturecontrol Spacesavingdesignandflexibleindoorunitoptions offerquickandeasyinstallation Superiorenergyefficiency,especiallyunderpartload conditions Softsoundlevelsforcomfort Singlesupplierreliability Straightforwardmaintenanceandservicewith selfdiagnosticfunctions
Refrigerant Piping
VRV
Compressor
39
BuiltinReliability
Launchedin1982,DaikinsVRVIIIsystemisthe7th generationoftheoriginalDaikinVRV.Redesignedand reengineeredtoincorporatethelatestadvancesin technologyandrefrigeration,Daikindesignsallofits majorcomponentstoensurebuiltinperformanceand reliability.
DesignFlexibility
Withawideselectionofductedandductfreeunits, indoorunitsareavailablein11differentstylesand51 modelsupto96,000Btu/h.Fromsleekandsophisticated designstoconcealedandcompactsystems,indoorunits provideaflexiblezoningsolutionforalmostany application.
DesignVersatility
VRVIIIprovidesdesignflexibilityfromresidentialtolarge commercialapplications.Availableinheatpumpandheat recoveryconfigurationsin208230Vand460V capabilities,systemsofferupto30toncapacityand operateupto62indoorunitsonasinglepipingnetwork.
AdvancedComfortControl
OptimizedforVRVtechnology,Daikinoffershighly scalablecontrolsolutionsforallapplications.Fromsingle zonetoadvancedmultizonecontrolswiththeabilityto integratewithabuildingautomationsystem,individual andpersonalizedcomfortisprovidedthrougha centralizedsystem.
EnergyEfficiencywithInverterTechnology
Integratedwithinvertertechnology,systemsvary compressorspeedtodelivertheamountofrefrigerantto thesystemrequiredtomaintainfluctuatingspaceneeds. Byoperatingataminimumvariablespeedtomaintain desiredroomconditions,systemsdelivermaximum efficiencyduringpartloadconditionsandprovideprecise individualzonecontrol.
SimplifiedInstallationandMaintenanceEase
Forsimplifiedinstallationandmaintenance,VRVsystems can: Automaticallychargethenecessaryamountof refrigerantneeded Checkwiring, shutoffvales,sensors,refrigerant volumeand Diagnoseerrorsandmalfunctionsto speedup troubleshooting allwithasimplepushofabutton onthePCB.
40
VRVIIIPBSeriesCertifiedData
DaikinsVRVsystemhasbeenvalidatedasoneofthemostefficientheatingand airconditioningsystemsavailableintheNorthAmericanmarket.
SystemType
PartLoad
IEER SCHE IEER SCHE Non Non Mixed Ducted Ducted Ducted SCHE EER Mixed Ducted EER Non Ducted EER Mixed COP@47F Ducted
FullLoad
COP@47F COP@17F COP@47F COP@17F COP@17F Non Non Mixed Ducted Mixed Ducted Ducted
Unit1 RXYQ72PBYD RXYQ96PBYD RXYQ120PBYD RXYQ72PBYD RXYQ96PBYD RXYQ120PBYD RXYQ120PBYD RXYQ120PBYD RXYQ96PBYD RXYQ120PBYD RXYQ120PBYD RXYQ120PBYD RXYQ120PBYD REYQ72PBYD REYQ96PBYD REYQ120PBYD REMQ72PBYD REMQ96PBYD REMQ96PBYD REMQ120PBYD REMQ120PBYD REMQ96PBYD REMQ120PBYD REMQ120PBYD REMQ120PBYD RXYQ72PBTJ RXYQ96PBTJ RXYQ120PBTJ RXYQ144PBTJ RXYQ96PBTJ RXYQ120PBTJ RXYQ120PBTJ RXYQ120PBTJ RXYQ96PBTJ RXYQ120PBTJ RXYQ120PBTJ RXYQ120PBTJ RXYQ120PBTJ REYQ72PBTJ REYQ96PBTJ REYQ120PBTJ REYQ144PBTJ REMQ96PBTJ REMQ96PBTJ REMQ120PBTJ REMQ120PBTJ REMQ96PBTJ REMQ120PBTJ REMQ120PBTJ REMQ120PBTJ
Unit2
Unit3
RXYQ72PBYD RXYQ96PBYD RXYQ120PBYD RXYQ144PBYD RXYQ168PBYD RXYQ192PBYD RXYQ216PBYD RXYQ240PBYD RXYQ264PBYD RXYQ288PBYD RXYQ312PBYD RXYQ336PBYD RXYQ360PBYD REYQ72PBYD REYQ96PBYD REYQ120PBYD REYQ144PBYD REYQ168PBYD REYQ192PBYD REYQ216PBYD REYQ240PBYD REYQ264PBYD REYQ288PBYD REYQ312PBYD REYQ336PBYD RXYQ72PBTJ RXYQ96PBTJ RXYQ120PBTJ RXYQ144PBTJ RXYQ168PBTJ RXYQ192PBTJ RXYQ216PBTJ RXYQ240PBTJ RXYQ264PBTJ RXYQ288PBTJ RXYQ312PBTJ RXYQ336PBTJ RXYQ360PBTJ REYQ72PBTJ REYQ96PBTJ REYQ120PBTJ REYQ144PBTJ REYQ168PBTJ REYQ192PBTJ REYQ216PBTJ REYQ240PBTJ REYQ264PBTJ REYQ288PBTJ REYQ312PBTJ REYQ336PBTJ
6Ton 8Ton 10Ton 12Ton 14Ton 16Ton 18Ton 20Ton 22Ton 24Ton 26Ton 28Ton 30Ton 6Ton 8Ton 10Ton 12Ton 14Ton 16Ton 18Ton 20Ton 22Ton 24Ton 26Ton 28Ton 6Ton 8Ton 10Ton 12Ton 14Ton 16Ton 18Ton 20Ton 22Ton 24Ton 26Ton 28Ton 30Ton 6Ton 8Ton 10Ton 12Ton 14Ton 16Ton 18Ton 20Ton 22Ton 24Ton 26Ton 28Ton
VRVIII460V
RXYQ72PBYD RXYQ72PBYD RXYQ72PBYD RXYQ96PBYD RXYQ120PBYD RXYQ96PBYD RXYQ96PBYD RXYQ120PBYD RXYQ120PBYD RXYQ120PBYD
VRVIII208/230V
21.5 18.8 17.2 22.1 20.2 19.1 19.5 16.1 19.1 18.8 17.0 16.1 15.3 21.3 19.7 16.1 20.0 19.4 16.9 16.4 15.4 18.1 17.5 16.2 15.9 21.5 18.8 17.2 17.6 20.2 19.1 19.5 16.1 19.1 18.8 17.0 16.1 15.3 21.3 19.7 16.1 16.5 19.4 16.9 16.4 15.4 18.1 17.5 16.2 15.9
25.8 23.0 20.4 21.5 22.0 19.9 19.2 18.2 20.8 19.6 18.2 15.9 15.1 25.1 22.9 21.3 22.5 20.3 18.7 17.2 16.1 18.7 19.0 16.9 15.6 25.8 23.0 20.4 20.5 22.0 19.9 19.2 18.2 20.8 19.6 18.2 15.9 15.1 25.1 22.9 21.3 18.9 20.3 18.7 17.2 16.1 18.7 19.0 16.9 15.6
23.7 20.9 18.8 21.8 21.1 19.5 19.4 17.2 20.0 19.2 17.6 16.0 15.2 23.2 21.3 18.7 21.3 19.9 17.8 16.8 15.8 18.4 18.3 16.6 15.8 23.7 20.9 18.8 19.1 21.1 19.5 19.4 17.2 20.0 19.2 17.6 16.0 15.2 23.2 21.3 18.7 17.7 19.9 17.8 16.8 15.8 18.4 18.3 16.6 15.8
12.8 12.5 11.9 12.7 12.1 11.8 11.7 11.6 11.7 10.5 11.5 10.7 10.8 18.0 15.4 15.3 16.0 16.2 15.5 15.0 14.8 15.9 15.8 15.4 14.9 21.1 20.0 19.6 19.8 19.0 18.8 17.9 17.5 19.8 18.9 18.9 18.3 19.55 17.7 17.45 17.9 17.6 16.9 16.45 16.15 17.85 17.35 17.15 16.6 13.8 12.1 11.3 13.7 11.5 11.0 10.8 10.1 11.3 10.7 10.3 10.2 12.8 12.5 11.9 11.3 12.1 11.8 11.7 11.6 11.7 10.5 11.5 10.7 10.8 13.8 12.1 11.3 10.6 11.5 11.0 10.8 10.1 11.3 10.7 10.3 10.2
14.1 13.5 12.5 14.0 12.4 11.7 11.6 11.5 11.3 11.5 10.7 10.8 9.8 15.4 13.2 12.1 13.8 12.0 11.2 10.7 10.1 10.8 10.7 10.2 10.2 14.1 13.5 12.5 11.3 12.4 11.7 11.6 11.5 11.3 11.5 10.7 10.8 9.8 15.4 13.2 12.1 11.2 12.0 11.2 10.7 10.1 10.8 10.7 10.2 10.2
13.4 13.0 12.2 13.4 12.3 11.8 11.7 11.6 11.5 11.0 11.1 10.8 10.3 14.6 12.7 11.7 13.8 11.8 11.1 10.8 10.1 11.1 10.7 10.3 10.2 13.4 13.0 12.2 11.3 12.3 11.8 11.7 11.6 11.5 11.0 11.1 10.8 10.3 14.6 12.7 11.7 10.9 11.8 11.1 10.8 10.1 11.1 10.7 10.3 10.2
18.0 15.4 15.3 16.0 16.2 15.5 15.0 14.8 15.9 15.8 15.4 14.9
21.1 20.0 19.6 19.8 19.0 18.8 17.9 17.5 19.8 18.9 18.9 18.3
19.55 17.7 17.45 17.9 17.6 16.9 16.45 16.15 17.85 17.35 17.15 16.6
3.71 3.65 3.63 3.70 3.70 3.55 3.60 3.50 3.50 3.45 3.30 3.45 3.20 3.80 3.60 3.40 3.60 3.50 3.40 3.30 3.20 3.30 3.40 3.33 3.20 3.71 3.65 3.63 3.40 3.70 3.55 3.60 3.50 3.50 3.45 3.30 3.45 3.20 3.80 3.60 3.40 3.40 3.50 3.40 3.30 3.20 3.30 3.40 3.33 3.20
4.00 4.20 3.80 3.90 3.95 3.70 3.80 3.60 3.50 3.50 3.30 3.45 3.45 4.20 3.70 3.60 3.80 3.70 3.40 3.50 3.33 3.40 3.35 3.23 3.23 4.00 4.20 3.80 3.60 3.95 3.70 3.80 3.60 3.50 3.50 3.30 3.45 3.45 4.20 3.70 3.60 3.60 3.70 3.40 3.50 3.33 3.40 3.35 3.23 3.23
3.86 3.93 3.72 3.80 3.83 3.63 3.70 3.55 3.50 3.48 3.30 3.45 3.33 4.00 3.65 3.50 3.70 3.60 3.40 3.40 3.27 3.35 3.38 3.28 3.22 3.86 3.93 3.72 3.50 3.83 3.63 3.70 3.55 3.50 3.48 3.30 3.45 3.33 4.00 3.65 3.50 3.50 3.60 3.40 3.40 3.27 3.35 3.38 3.28 3.22
2.40 2.50 2.50 2.45 2.45 2.45 2.45 2.35 2.30 2.45 2.35 2.35 2.40 2.60 2.65 2.35 2.40 2.35 2.30 2.30 2.35 2.30 2.35 2.25 2.20 2.40 2.50 2.50 2.45 2.45 2.45 2.45 2.35 2.30 2.45 2.35 2.35 2.40 2.60 2.65 2.35 2.40 2.35 2.30 2.30 2.35 2.30 2.35 2.25 2.20
2.65 2.85 2.65 2.55 2.65 2.55 2.60 2.55 2.45 2.45 2.35 2.35 2.40 2.95 2.70 2.60 2.55 2.50 2.50 2.40 2.40 2.40 2.40 2.25 2.30 2.65 2.85 2.65 2.55 2.65 2.55 2.60 2.55 2.45 2.45 2.35 2.35 2.40 2.95 2.70 2.60 2.55 2.50 2.50 2.40 2.40 2.40 2.40 2.25 2.30
2.53 2.68 2.58 2.50 2.55 2.50 2.53 2.45 2.38 2.45 2.35 2.35 2.40 2.78 2.68 2.48 2.48 2.43 2.40 2.35 2.38 2.35 2.38 2.25 2.25 2.53 2.68 2.58 2.50 2.55 2.50 2.53 2.45 2.38 2.45 2.35 2.35 2.40 2.78 2.68 2.48 2.48 2.43 2.40 2.35 2.38 2.35 2.38 2.25 2.25
HeatRecovery
HeatPump
HeatRecovery
HeatPump
VRV
41
208230VHeatPump
RXYQ_PBTJ
Acomplete,engineeredheatingandcooling solution.
Keyfeaturesinclude: Extendedoperatingrangewiththeabilitytooperate atoutdoorambientconditionsdownto23Fin coolingmodeanddownto4Finheatingmode. Longrefrigerantpipinglengthswithupto3,280ft.of totalonewaypipinginthecompletepiping network Advanceddefrostcycleoperationinheating Automaticchargefunction
6 Ton
RXYQ72PBTJ
8 Ton
RXYQ96PBTJ
10 Ton
RXYQ120PBTJ
12 Ton
RXYQ144PBTJ
14 Ton
16 Ton
18 Ton
Performance
Unit
RXYQ168PBTJ RXYQ192PBTJ RXYQ216PBTJ 1 x RXYQ96PBTJ 1 x RXYQ120PBTJ 1 x RXYQ120PBTJ 1 x RXYQ72PBTJ 1 x RXYQ72PBTJ 1 x RXYQ96PBTJ 69,000 92,000 114,000 138,000 160,000 184,000 206,000 77,000 103,000 129,000 154,000 180,000 206,000 231,000 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 57 60 60 62 62 62 63 6,350 8,230 8,230 8,300 8,230 + 6,350 8,230 + 6,350 8,230 + 8,230 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 295 295 295 295 295 295 295 540 540 540 540 540 540 540 620 620 620 620 620 620 620 3,280 3,280 3,280 3,280 3,280 3,280 3,280 420 620 620 747 620 + 420 620 + 420 620 + 620 66-1/8 x 51-3/16 x (66-1/8 x 48-7/8 x 30-1/8) + (66-1/8 x 48-7/8 x 66-1/8 x 36-5/8 x 66-1/8 x 48-7/8 x 30-1/8 30-1/8 30-1/8 (66-1/8 x 36-5/8 x 30-1/8) 30-1/8) x2
20 Ton
RXYQ240PBTJ
22 Ton
RXYQ264PBTJ 2 x RXYQ96PBTJ 1 x RXYQ72PBTJ
24 Ton
26 Ton
28 Ton
30 Ton
RXYQ288PBTJ RXYQ312PBTJ RXYQ336PBTJ RXYQ360PBTJ 1 x RXYQ120PBTJ 2 x RXYQ120PBTJ 2 x RXYQ120PBTJ Model Combination 2 x RXYQ120PBTJ 1 x RXYQ96PBTJ 1 xRXYQ72PBTJ 1 x RXYQ96PBTJ 3 x RXYQ120PBTJ 1 x RXYQ72PBTJ Btu/h 228,000 251,000 274,000 297,000 320,000 342,000 Rated Cooling Capacity Btu/h 257,000 283,000 308,000 334,000 360,000 385,000 Rated Heating Capacity F DB 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 Operating Range - Cooling Performance F DB 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 Operating Range - Heating V/Ph/Hz 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 Power dB(A) 63 64 64 64 65 65 Sound Pressure Level @3ft Fan cfm 8,230 + 8,230 8,230 + 8,230 + 6,350 8,230 + 8,230 + 6,350 8,230 + 8,230 + 6,350 8,230 + 8,230 + 8,230 8,230 + 8,230 + 8,230 Airflow ft. 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) Vertical Pipe Length Above ft. 295 295 295 295 295 295 Vertical Pipe Length Below Refrigerant ft. 540 540 540 540 540 540 Actual Pipe Length Piping ft. 620 620 620 620 620 620 Equivalent Pipe Length ft. 3,280 3,280 3,280 3,280 3,280 3,280 Total Pipe Length lbs. 620 + 620 620 + 620 + 420 620 + 620 + 420 620 + 620 + 420 620 + 620 + 620 620 + 620 + 620 Weight Unit (66-1/8 x 48-7/8 x in. (66-1/8 x 48-7/8 x 30-1/8) x 2 + (66-1/8 x 36-5/8 x 30-1/8) (66-1/8 x 48-7/8 x 30-1/8) x 3 Dimensions (H x W x D) 30-1/8) x 2 For all equipment installation and application limitations please refer to the specific Engineering Data Books.
42
208230VHeatRecovery
REYQ_PBTJ
Simultaneousheatingandcoolingfromasingle system.
Keyfeaturesinclude: Extendedoperatingrangewiththeabilitytooperate atoutdoorambientconditionsdownto23Fwithan optiondownto4Fincoolingmodeanddownto 4Finheatingmode. Longrefrigerantpipinglengthswithupto3,280ft.of totalonewaypipinginthecompletepiping network Advancedcontinuousheatingduringdefrostcycle Automaticchargefunction
6 Ton
REYQ72PBTJ
8 Ton
REYQ96PBTJ
10 Ton
REYQ120PBTJ
12 Ton
REYQ144PBTJ
14 Ton
16 Ton
18 Ton
Performance
Unit
REYQ168PBTJ REYQ192PBTJ REYQ216PBTJ 1x REMQ96PBTJ + 1x REMQ120PBTJ + 2x REMQ96PBTJ 1x REMQ72PBTJ 1x REMQ96PBTJ 69,000 92,000 114,000 138,000 160,000 184,000 206,000 77,000 103,000 129,000 154,000 180,000 206,000 231,000 (-4) 23 122 (-4) 23 122 (-4) 23 122 (-4) 23 122 (-4) 23 122 (-4) 23 122 (-4) 23 122 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 58 58 60 62 61 62 62 6,700 6,700 7,410 8,300 6,530 + 6,350 6,530 + 6,530 7,060 + 6,530 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 295 295 295 295 295 295 295 540 540 540 540 540 540 540 620 620 620 620 620 620 620 3,280 3,280 3,280 3,280 3,280 3,280 3,280 730 730 730 747 560 + 450 560 + 560 560 + 560 66-1/8 x 51-3/16 x 30-1/8 (66-1/8 x 36-5/8 x 30-1/8) x 2
20 Ton
REYQ240PBTJ 2 x REMQ120PBTJ 240,000 257,000 (-4) 23 122 0 - 77 208-230/3/60 63 7,060 + 7,060
22 Ton
REYQ264PBTJ
24 Ton
26 Ton
28 Ton
Performance
REYQ288PBTJ REYQ312PBTJ REYQ336PBTJ 1 x REMQ120PBTJ + 2 x REMQ96PBTJ + 1 x REMQ120PBTJ + 2 x REMQ120PBTJ + 1 x REMQ96PBTJ + 1 x REMQ72PBTJ 2 xREMQ96PBTJ 1 x REMQ96PBTJ 1 x REMQ72PBTJ 251,000 274,000 297,000 320,000 283,000 308,000 334,000 360,000 (-4) 23 122 (-4) 23 122 (-4) 23 122 (-4) 23 122 0 - 77 0 - 77 0 - 77 0 - 77 208-230/3/60 208-230/3/60 208-230/3/60 208-230/3/60 62 63 64 64 6,530 + 6,530 + 6,350 7,060 + 6,530 + 6,350 7,060 + 6,530 + 6,530 7,060 + 7,060 +6530
Unit
164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 295 295 295 295 295 540 540 540 540 540 620 620 620 620 620 3,280 3,280 3,280 3,280 3,280 560 + 560 560 + 560 + 450 560 + 560 + 450 560 + 560 + 560 560 + 560 + 560 (66-1/8 x 36-5/8 x (66-1/8 x 36-5/8 x 30-1/8) x 3 30-1/8) x 2
VRV
For all equipment installation and application limitations please refer to the specific Engineering Data Books.
Low Ambient Cooling Wind Hood / Hail Guard Accessory Kit - Full Kit consists of 4 complete hood sections for the back, left, right and top portions of the outdoor unit. Partial Kit for multiple unit installations consists of 2 complete hood sections for the back and top portions of the outdoor unit only.
Full Kit Model DACA-WH36F DACA-WH51F Partial Kit Model DACA-WH36P DACA-WH51P Indoor Units REYQ144-336PBTJ REYQ72-144PBTJ Indoor Units REYQ144-336PBTJ REYQ72-144PBTJ Note:TheVRVIIIwindhoodaccessories aredesignedtobeusedinconjunctionwithanoutdoorunitfieldsettingandapplicable branchselector unitdipswitchsettingstoengagethelowambientcoolingfeatureforheatrecoveryunits only.Pleasereferto theDACAWH36_51F/PInstallationManualforadditionalinformation. Thisaccessoryiscurrentlyavailableforall365/8and513/16widthheatrecoveryunits.
43
460VHeatPump
RXYQ_PBYD
Acomplete,engineeredheatingandcooling solution.
Keyfeaturesinclude: Extendedoperatingrangewiththeabilitytooperate atoutdoorambientconditionsdownto23Fin coolingmodeanddownto4Finheatingmode. Longrefrigerantpipinglengthswithupto3,280ft.of totalonewaypipinginthecompletepiping network Advanceddefrostcycleoperationinheating Automaticchargefunction
6 Ton
RXYQ72PBYD
8 Ton
RXYQ96PBYD
10 Ton
RXYQ120PBYD
12 Ton
RXYQ144PBYD
14 Ton
16 Ton
18 Ton
Performance
Unit
RXYQ168PBYD RXYQ192PBYD RXYQ216PBYD 1 x RXYQ96PBYD + 1 x RXYQ120PBYD + 1 x RXYQ120PBYD + 2 x RXYQ72PBYD 1 x RXYQ72PBYD 1 x RXYQ72PBYD 1 x RXYQ96PBYD 69,000 92,000 114,000 138,000 160,000 184,000 206,000 77,000 103,000 129,000 154,000 180,000 206,000 231,000 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 57 60 60 62 62 62 63 6,350 8,230 8,230 6,350 + 6,350 8,230 + 6,350 8,230 + 6,350 8,230 + 8,230 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 295 295 295 295 295 295 295 540 540 540 540 540 540 540 620 620 620 620 620 620 620 3,280 3,280 3,280 3,280 3,280 3,280 3,280 433 633 633 433 + 433 633 + 433 633 + 433 633 + 633 66-1/8 x 36-5/8 x (66-1/8 x 36-5/8 x (66-1/8 x 48-7/8 x 30-1/8) + (66-1/8 x 48-7/8 x 66-1/8 x 48-7/8 x 30-1/8 30-1/8 30-1/8) x 2 (66-1/8 x 36-5/8 x 30-1/8) 30-1/8) x 2
20 Ton
RXYQ240PBYD 2 x RXYQ120PBYD
22 Ton
RXYQ264PBYD 2 x RXYQ96PBYD + 1 x RXYQ72PBYD
24 Ton
RXYQ288PBYD 1 x RXYQ120PBYD + 1 x RXYQ96PBYD + 1 x RXYQ72PBYD 274,000 308,000 23 - 122 0 - 77 460/3/60 64 8,230 + 8,230 + 6,350 164 (295 with option) 295 540 620 3,280 633 + 633 + 433
26 Ton
RXYQ312PBTJ
28 Ton
RXYQ336PBTJ
30 Ton
RXYQ360PBTJ
228,000 251,000 297,000 320,000 342,000 257,000 283,000 334,000 360,000 385,000 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122 Performance 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 63 64 64 65 65 Fan 8,230 + 8,230 8,230 + 8,230 + 6,350 8,230 + 8,230 + 6,350 8,230 + 8,230 + 8,230 8,230 + 8,230 + 8,230 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 295 295 295 295 295 Refrigerant 540 540 540 540 540 Piping 620 620 620 620 620 3,280 3,280 3,280 3,280 3,280 633 + 633 633 + 633 + 433 633 + 633 + 433 633 + 633 + 633 633 + 633 + 633 Unit (66-1/8 x 48-7/8 x Dimensions (H x W x D) in. (66-1/8 x 48-7/8 x 30-1/8) x 2 + (66-1/8 x 36-5/8 x 30-1/8) (66-1/8 x 48-7/8 x 30-1/8) x 3 30-1/8) x 2 For all equipment installation and application limitations please refer to the specific Engineering Data Books.
44
460VHeatRecovery
REYQ_PBYD
Simultaneousheatingandcoolingfromasingle system.
Keyfeaturesinclude:
Extendedoperatingrangewiththeabilitytooperate atoutdoorambientconditionsdownto23Fwithan optiondownto4Fincoolingmodeanddownto 4Finheatingmode. Longrefrigerantpipinglengthswithupto3,280ft.of totalonewaypipinginthecompletepiping network Advancedcontinuousheatingduringdefrostcycle Automaticchargefunction
6 Ton
REYQ72PBYD
8 Ton
REYQ96PBYD
10 Ton
REYQ120PBYD
12 Ton
REYQ144PBYD
14 Ton
16 Ton
18 Ton
Performance
Unit
REYQ168PBYD REYQ192PBYD REYQ216PBYD 1 x REMQ96PBYD + 1 x REMQ120PBYD + 2 x REMQ72PBYD 2 x REMQ96PBYD 1 x REMQ72PBYD 1 x REMQ96PBYD 69,000 92,000 114,000 138,000 160,000 184,000 206,000 77,000 103,000 129,000 154,000 180,000 206,000 231,000 (-4) 23 - 122 (-4) 23 - 122 (-4) 23 - 122 (-4) 23 - 122 (-4) 23 - 122 (-4) 23 - 122 (-4) 23 - 122 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 0 - 77 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 460/3/60 58 58 60 60 61 62 62 6,700 6,700 6,700 6,350 + 6,350 6,530 + 6,350 6,530 + 6,530 7,060 + 6,530 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 164 (295 with option) 295 295 295 295 295 295 295 540 540 540 540 540 540 540 620 620 620 620 620 620 620 3,280 3,280 3,280 3,280 3,280 3,280 3,280 732 732 732 463 + 463 573 + 463 573 + 573 573 + 573 66-1/8 x 51-3/16 x 30-1/8 (66-1/8 x 36-5/8 x 30-1/8) x 2
20 Ton
REYQ240PBYD 2 x REMQ120PBYD
22 Ton
REYQ264PBYD 2 x REMQ96PBYD + 1 x REMQ72PBYD
24 Ton
REYQ288PBYD 1 x REMQ120PBYD + 1 x REMQ96PBYD+ 1x REMQ72PBYD 274,000 308,000 (-4) 23 - 122 0 - 77 460/3/60 63 7060 + 6,530 + 6,350 164 (295 with option) 295 540 620 3,280 573 + 573 + 463
26 Ton
REYQ312PBYD
28 Ton
REYQ336PBYD
2 x REMQ96PBYD + 2 x REMQ120PBYD + 1 x REMQ120PBYD 1 x REMQ96PBYD 297,000 320,000 334,000 360,000 (-4) 23 - 122 (-4) 23 - 122 0 - 77 0 - 77 460/3/60 460/3/60 64 64 7,060 + 6,530 + 6,530 7,060 + 7,060 + 6,530 164 (295 with option) 164 (295 with option) 295 295 540 540 620 620 3,280 3,280 573 + 573 + 573 573 + 573 + 573
Performance
Unit
240,000 251,000 257,000 283,000 (-4) 23 - 122 (-4) 23 - 122 0 - 77 0 - 77 460/3/60 460/3/60 63 62 7,060 + 7,060 6,530 + 6,530 + 6,530 164 (295 with option) 164 (295 with option) 295 295 540 540 620 620 3,280 3,280 573 + 573 573 + 573 + 463 (66-1/8 x 36-5/8 x 30-1/8) x 2
VRV
For all equipment installation and application limitations please refer to the specific Engineering Data Books.
Low Ambient Cooling Wind Hood / Hail Guard Accessory Kit - Full Kit consists of 4 complete hood sections for the back, left, right and top portions of the outdoor unit. Partial Kit for multiple unit installations consists of 2 complete hood sections for the back and top portions of the outdoor unit only.
Full Kit Model DACA-WH36F DACA-WH51F Partial Kit Model DACA-WH36P DACA-WH51P Indoor Units REYQ144-336PBYD REYQ72-120PBYD Indoor Units REYQ144-336PBYD REYQ72-120PBYD Note:TheVRVIIIwindhoodaccessories aredesignedtobeusedinconjunctionwithanoutdoorunitfieldsettingandapplicable branchselector unitdipswitchsettingstoengagethelowambientcoolingfeatureforheatrecoveryunits only.Pleasereferto theDACAWH36_51F/PInstallationManualforadditionalinformation. Thisaccessoryiscurrentlyavailableforall365/8and513/16widthheatrecoveryunits.
45
VRVWIIIFeaturesandBenefits
Reliability,comfortandefficiencyworkingtogetherhand inhand AllVRVWIIIincorporateDaikinsuniquevariablespeed scrollcompressorattheheartofthesystem.Thisprovides theexactcapacitywhereandwhenitisneeded,industry leadingreliabilityandhighpartloadoperationefficiency. Compactandlightweight Industryleadingcompactlightweightcasing Height:393/8,Weight:330lbs.Installinamechanical room,doubledeckerstyleifneeded. Largecapacity(6to21Ton) Largersinglesystemcapacityensureswiderapplication rangeforsatisfyingfloorbyfloorloadsofcommercial buildings. Widewatertemperatureoperationrange AsstandardVRVWIIIcanoperatewithcondenserwater temperaturesdownto50Fbutthiscanbeextendedtoan industryleading14Finheating.
TheVRVWIIIdesignisbasedonamodular design concept.Itiscomposedofunified condensingunitsthatrequiresimplyconnectinga 2piperefrigerantnetworkforheatpump applicationsora3piperefrigerantnetworkfor heatrecoveryapplications.Allwatercooled condensersareofthesamedimensions,andare availablein6Tonand7Ton.Thisisasimple systemthatallowsmanifoldingtogetherupto3 condenserstoformonesystemofupto21Ton (252MBH).Thecondensersaredesignedfor internalmountingonly.
46
VRVWIIICertifiedData
DaikinsVRVWIIIsystemhasbeenvalidatedasoneofthemostefficient heatingandairconditioningsystemsavailableintheNorthAmericanmarket.
SystemType
PartLoad
IEER IEER IEER Non Ducted Mixed Ducted SCHE Non Ducted SCHE Ducted SCHE Mixed
FullLoad
EER COP@68F EER EER COP@68F Non Non Ducted Mixed Ducted Ducted Ducted COP@68F Mixed
Unit1 RWEYQ72PYDN RWEYQ84PYDN RWEYQ72PYDN RWEYQ84PYDN RWEYQ72PYDN RWEYQ84PYDN RWEYQ72PYDN RWEYQ84PYDN RWEYQ72PYDN RWEYQ84PYDN RWEYQ72PYDN RWEYQ84PYDN RWEYQ72PTJU RWEYQ84PTJU RWEYQ72PTJU RWEYQ84PTJU RWEYQ72PTJU RWEYQ84PTJU RWEYQ72PTJU RWEYQ84PTJU RWEYQ72PTJU RWEYQ84PTJU RWEYQ72PTJU RWEYQ84PTJU
Unit2
Unit3
RWEYQ72PYDN RWEYQ84PYDN RWEYQ144PYDN RWEYQ168PYDN RWEYQ216PYDN RWEYQ252PYDN RWEYQ72PYDN RWEYQ84PYDN RWEYQ144PYDN RWEYQ168PYDN RWEYQ216PYDN RWEYQ252PYDN RWEYQ72PTJU RWEYQ84PTJU RWEYQ144PTJU RWEYQ168PTJU RWEYQ216PTJU RWEYQ252PTJU RWEYQ72PTJU RWEYQ84PTJU RWEYQ144PTJU RWEYQ168PTJU RWEYQ216PTJU RWEYQ252PTJU
6Ton 7Ton 12Ton 14Ton 18Ton 21Ton 6Ton 7Ton 12Ton 14Ton 18Ton 21Ton 6Ton 7Ton 12Ton 14Ton 18Ton 21Ton 6Ton 7Ton 12Ton 14Ton 18Ton 21Ton
VRVWIII460V
RWEYQ72PYDN RWEYQ84PYDN
RWEYQ72PYDN RWEYQ84PYDN
VRVWIII208/230V
RWEYQ72PTJU RWEYQ84PTJU
RWEYQ72PTJU RWEYQ84PTJU
24.1 22.5 23.7 23.1 22.7 21.5 24.1 22.5 23.7 23.1 22.7 21.5 24.1 22.5 23.7 23.1 22.7 21.5 24.1 22.5 23.7 23.1 22.7 21.5
22.3 21.3 22.3 21.3 22.2 20.0 22.3 21.3 22.3 21.3 22.2 20.0 22.3 21.3 22.3 21.3 22.2 20.0 22.3 21.3 22.3 21.3 22.2 20.0
23.2 21.9 23.0 22.2 22.5 20.8 23.2 21.9 23.0 22.2 22.5 20.8 23.2 21.9 23.0 22.2 22.5 20.8 23.2 21.9 23.0 22.2 22.5 20.8
14.0 13.4 14.6 12.7 14.5 12.8 14.0 13.4 14.6 12.7 14.5 12.8 14.0 13.4 14.6 12.7 14.5 12.8 14.0 13.4 14.6 12.7 14.5 12.8
14.0 13.2 14.4 12.7 14.5 12.8 14.0 13.2 14.4 12.7 14.5 12.8 14.0 13.2 14.4 12.7 14.5 12.8 14.0 13.2 14.4 12.7 14.5 12.8
14.0 13.3 14.5 12.7 14.5 12.8 14.0 13.3 14.5 12.7 14.5 12.8 14.0 13.3 14.5 12.7 14.5 12.8 14.0 13.3 14.5 12.7 14.5 12.8
4.89 4.70 4.97 4.38 4.80 4.48 4.89 4.70 4.97 4.38 4.80 4.48 4.89 4.70 4.97 4.38 4.80 4.48 4.89 4.70 4.97 4.38 4.80 4.48
4.89 4.50 4.97 4.38 4.91 4.48 4.89 4.50 4.97 4.38 4.91 4.48 4.89 4.50 4.97 4.38 4.91 4.48 4.89 4.50 4.97 4.38 4.91 4.48
4.89 4.60 4.97 4.38 4.86 4.48 4.89 4.60 4.97 4.38 4.86 4.48 4.89 4.60 4.97 4.38 4.86 4.48 4.89 4.60 4.97 4.38 4.86 4.48
HeatRecovery
HeatPump
HeatRecovery
HeatPump
VRV
CertifiedefficiencydatainaccordancewithANSI/AHRIStandard12302010,PerformanceRatingofVariableRefrigerantFlow(VRF)MultiSplitAirConditioningandHeatPumpEquipmentforthe VRVWIIIPSeries.TheVRVWIIIPSerieshasbeendesignedandoptimizedtomeet/orexceedthelatestminimumefficiencyrequirementsin10C.F.R.Part431asdeterminedbytheU.S.Departmentof Energy(DOE) andbaselineefficienciesasdefinedbyASHRAE90.1 2010.Systemsunder65MBHarecurrentlycertifiedtoAHRI210/240.IEERratingsareasdefinedinASHRAE90.12010.
47
Single ModuleSystem208230V
RWEYQ_PTJU
Amodular,energysavingandreliable alternativetocentralizedequipment.
Keyfeaturesinclude: Compactlightweightcasingat393/8inheightand 330lbs.inweight Smallcondenserscanbestackedforreduced installationspaceandincreasedusablesquare footage Largersinglesystemcapacityandmodularconcept ensureswiderapplicationrangeforsatisfyingfloor byfloorloadsofcommercialbuildings AsstandardVRVWIIIcanoperatewithcondenser watertemperaturesdownto50Fbutthiscanbe extendedtoanindustryleading14Finheating
6 Ton
RWEYQ72PTJU 72,000 4.2 81,000 4.0 208-230/3/60 Heat Pump 3/8 3/4 N/A 50
7 Ton
RWEYQ84PTJU 84,000 5.6 94,000 5.4
51 Heat Recovery Heat Pump Heat Recovery 3/8 3/8 3/8 3/4 7/8 7/8 5/8 N/A 3/4 164 (130) 164 (130) 390 (459) 390 (459) 980 980 50 - 130 50 - 130 12 14 1-1/4 FPT 1-1/4 FPT 1-1/4 FPT 1-1/4 FPT 1/2 FPS 1/2 FPS 285 285 50 - 113 50 - 113 16.4 ~ 39.5 (13.2) 16.4 ~ 39.5 (13.2) 27 (34***) - 113 27 (34***) - 113 14 - 113 14 - 113 21 - 40 21 - 40 330 330 39-3/8 x 30-3/4 x 21-11/16 187 - 253 187 - 253 40 40 22.4 22.4 11.6 15.4 Daikin G-Type Scroll Daikin G-Type Scroll 1 INV 1 INV 23 - 100 23 - 100
48
DoubleModuleSystem208230V
RWEYQ_PTJU
Amodular,energysavingandreliablealternativeto centralizedequipment. Keyfeaturesinclude: Compactlightweightcasingat393/8inheightand 330lbs.inweight Smallcondenserscanbestackedforreduced installationspaceandincreasedusablesquare footage Largersinglesystemcapacityandmodularconcept ensureswiderapplicationrangeforsatisfyingfloor byfloorloadsofcommercialbuildings AsstandardVRVWIIIcanoperatewithcondenser watertemperaturesdownto50Fbutthiscanbe extendedtoanindustryleading14Finheating
12 Ton
14 Ton
Name RWEYQ144PTJU RWEYQ168PTJU Combination 2 x RWEYQ72PTJU 2 x RWEYQ84PTJU Cooling Capacity Btu/h 144,000 168,000 Cooling Input Power kW 8.4 11.2 162,000 189,000 Heating Capacity Btu/h Performance Heating Input Power kW 8.0 10.8 208-230/3/60 Power V/ph/Hz Sound Pressure Level @ 3ft. dB(A) 53 54 System Configuration Heat Pump Heat Recovery Heat Pump Heat Recovery Liquid Pipe (Main Line) in. 1/2 1/2 5/8 5/8 Suction Gas Pipe (Main Line) in. 1-1/8 1-1/8 1-1/8 1-1/8 Refrigerant Piping Discharge Gas Pipe (Main Line) in. N/A 7/8 N/A 7/8 Vertical Pipe Length (if unit is below FCU) ft. 164 (130) 164 (130) Actual Pipe Length (Equivalent Length) ft. 390 (459) 390 (459) Total Pipe Length ft. 980 980 Standard Connectable Indoor Unit Ratio % 50 - 130 50 - 130 Connection Ratio Maximum Number of Indoor Units Qty. 20 20 BPHE Inlet Pipe (Female Thread) in. 2 x (1-1/4 FPT) 2 x (1-1/4 FPT) BPHE Outlet Pipe (Female Thread) in. 2 x (1-1/4 FPT) 2 x (1-1/4 FPT) Drain Pipe (Female Thread) in. 2 x (1/2 FPS) 2 x (1/2 FPS) Water Side (Standard) Maximum System Water Pressure (BPHE) psi 285 285 Standard Inlet Water Temperature Range F 50 - 113 50 - 113 Recommended Inlet Water Flow Rate per Module (min.)* gpm 16.4 ~ 39.5 (13.2) 16.4 ~ 39.5 (13.2) Inlet Water Temperature Range Cooling** F 27 (34***) - 113 27 (34***) - 113 Water Side Inlet Water Temperature Range Heating F 14 - 113 14 - 113 (Geothermal) Water Flow Rate gpm 21 - 40 21 - 40 Weight lbs. 2 x 330 2 x 330 Unit Dimensions (H x W x D) in. 39-3/8 x (30-3/4 x 2) x 21-11/16 Voltage Range (min - max) V/ph/Hz 187 - 253 187 - 253 Maximum Overcurrent Protection (MOP) A 40 + 40 40 + 40 Electrical Minimum Circuit Amps (MCA) A 22.4 + 22.4 22.4 + 22.4 Compressor Rated Load Amps (RLA) A 11.6 + 11.6 15.4 + 15.4 Compressor Type Daikin G-Type Scroll Daikin G-Type Scroll Compressor Compressor Set-Up 1 INV + 1 INV 1 INV + 1 INV Compressor Capacity Control % 11 - 100 11 100 1 Indoor temp. : 80FDB, 67FWB/inlet water temp. : 85F/outlet water temp. : 95F Equivalent piping length : 25ft, level difference : 0ft. 2 Indoor temp. : 70FDB, 60FWB/inlet water temp. : 70F/Equivalent piping length : 25ft, level difference : 0ft. * Please note that a water strainer is required for each condensing unit model and now must be field supplied (strainer specification = 50 mesh). ** Application rules apply below 48F. Please contact your local Daikin office for design assistance and approval. *** The minimum cooling EWT is 34F when the condensing unit is located below the indoor units.
VRV
49
TripleModuleSystem208230V
RWEYQ_PTJU
Amodular,energysavingandreliablealternativeto centralizedequipment. Keyfeaturesinclude: Compactlightweightcasingat393/8inheightand 330lbs.inweight Smallcondenserscanbestackedforreduced installationspaceandincreasedusablesquare footage Largersinglesystemcapacityandmodularconcept ensureswiderapplicationrangeforsatisfyingfloor byfloorloadsofcommercialbuildings AsstandardVRVWIIIcanoperatewithcondenser watertemperaturesdownto50Fbutthiscanbe extendedtoanindustryleading14Finheating
18 Ton
21 Ton
Name RWEYQ216PTJU RWEYQ252PTJU Combination 3 x RWEYQ72PTJU 3 x RWEYQ84PTJU Cooling Capacity Btu/h 216,000 252,000 Cooling Input Power kW 12.6 16.8 Heating Capacity Btu/h 243,000 283,500 Performance Heating Input Power kW 12.0 16.2 Power V/ph/Hz 208-230/3/60 Sound Pressure Level @ 3ft. dB(A) 56 57 System Configuration Heat Pump Heat Recovery Heat Pump Heat Recovery Liquid Pipe (Main Line) in. 5/8 5/8 3/4 3/4 Suction Gas Pipe (Main Line) in. 1-3/8 1-3/8 1-3/8 1-3/8 Refrigerant Piping Discharge Gas Pipe (Main Line) in. N/A 1-1/8 N/A 1-1/8 Vertical Pipe Length (if unit is below FCU) ft. 164 (130) 164 (130) Actual Pipe Length (Equivalent Length) ft. 390 (459) 390 (459) Total Pipe Length ft. 980 980 Standard Connectable Indoor Unit Ratio % 50 - 130 50 - 130 Connection Ratio Maximum Number of Indoor Units Qty. 22 22 BPHE Inlet Pipe (Female Thread) in. 3 x (1-1/4 FPT) 3 x (1-1/4 FPT) BPHE Outlet Pipe (Female Thread) in. 3 x (1-1/4 FPT) 3 x (1-1/4 FPT) Drain Pipe (Female Thread) in. 3 x (1/2 FPS) 3 x (1/2 FPS) Water Side (Standard) Maximum System Water Pressure (BPHE) psi 285 285 Standard Inlet Water Temperature Range F 50 - 113 50 - 113 Recommended Inlet Water Flow Rate per Module (min.)* gpm 16.4 ~ 39.5 (13.2) 16.4 ~ 39.5 (13.2) Inlet Water Temperature Range Cooling** F 27 (34***) - 113 27 (34***) - 113 Water Side Inlet Water Temperature Range Heating F 14 - 113 14 - 113 (Geothermal) Water Flow Rate gpm 21 - 40 21 - 40 Weight lbs. 3 x 330 3 x 330 Unit Dimensions (H x W x D) in. 39-3/8 x (30-3/4 x 3) x 21-11/16 Voltage Range (min - max) V/ph/Hz 187 - 253 187 - 253 Maximum Overcurrent Protection (MOP) A 40 + 40 + 40 40 + 40 + 40 Electrical Minimum Circuit Amps (MCA) A 22.4 + 22.4 + 22.4 22.4 + 22.4 + 22.4 Compressor Rated Load Amps (RLA) A 11.6 + 11.6 + 11.6 11.6 + 11.6 + 11.6 Compressor Type Daikin G-Type Scroll Daikin G-Type Scroll Compressor Compressor Set-Up 1 INV + 1 INV + 1 INV 1 INV + 1 INV + 1 INV Compressor Capacity Control % 8 - 100 8 - 100 1 Indoor temp. : 80FDB, 67FWB/inlet water temp. : 85F/outlet water temp. : 95F Equivalent piping length : 25ft, level difference : 0ft. 2 Indoor temp. : 70FDB, 60FWB/inlet water temp. : 70F/Equivalent piping length : 25ft, level difference : 0ft. * Please note that a water strainer is required for each condensing unit model and now must be field supplied (strainer specification = 50 mesh). ** Application rules apply below 48F. Please contact your local Daikin office for design assistance and approval. *** The minimum cooling EWT is 34F when the condensing unit is located below the indoor units.
50
SingleModuleSystem460V
RWEYQ_PYDN
Amodular,energysavingandreliablealternativeto centralizedequipment. Keyfeaturesinclude: Compactlightweightcasingat393/8inheightand 330lbs.inweight Smallcondenserscanbestackedforreduced installationspaceandincreasedusablesquare footage Largersinglesystemcapacityandmodularconcept ensureswiderapplicationrangeforsatisfyingfloor byfloorloadsofcommercialbuildings AsstandardVRVWIIIcanoperatewithcondenser watertemperaturesdownto50Fbutthiscanbe extendedtoanindustryleading14Finheating
6 Ton
RWEYQ72PYDN 72,000 4.2 81,000 4.0 460/3/60 Heat Pump 3/8 3/4 N/A 50
7 Ton
RWEYQ84PYDN 84,000 5.6 94,000 5.4
51 Heat Recovery Heat Pump Heat Recovery 3/8 3/8 3/8 3/4 7/8 7/8 5/8 N/A 3/4 164 (130) 164 (130) 390 (459) 390 (459) 980 980 50 - 130 50 - 130 12 14 1-1/4 FPT 1-1/4 FPT 1-1/4 FPT 1-1/4 FPT 1/2 FPS 1/2 FPS 285 285 50 - 113 50 - 113 16.4 ~ 39.5 (13.2) 16.4 ~ 39.5 (13.2) 27 (34***) - 113 27 (34***) - 113 14 - 113 14 - 113 21 - 40 21 - 40 330 330 39-3/8 x 30-3/4 x 21-11/16 414 - 506 414 - 506 15 15 10.2 10.2 5.3 7.0 Daikin G-Type Scroll Daikin G-Type Scroll 1 INV 1 INV 23 - 100 23 - 100
VRV
51
DoubleModuleSystem460V
RWEYQ_PYDN
Amodular,energysavingandreliablealternativeto centralizedequipment. Keyfeaturesinclude: Compactlightweightcasingat393/8inheightand 330lbs.inweight Smallcondenserscanbestackedforreduced installationspaceandincreasedusablesquare footage Largersinglesystemcapacityandmodularconcept ensureswiderapplicationrangeforsatisfyingfloor byfloorloadsofcommercialbuildings AsstandardVRVWIIIcanoperatewithcondenser watertemperaturesdownto50Fbutthiscanbe extendedtoanindustryleading14Finheating
12 Ton
14 Ton
Name RWEYQ144PYDN RWEYQ168PYDN Combination 2 x RWEYQ72PYDN 2 x RWEYQ84PYDN Cooling Capacity Btu/h 144,000 168,000 Cooling Input Power kW 8.4 11.2 162,000 189,000 Heating Capacity Btu/h Performance Heating Input Power kW 8.0 10.8 460/3/60 Power V/ph/Hz Sound Pressure Level @ 3ft. dB(A) 53 54 System Configuration Heat Pump Heat Recovery Heat Pump Heat Recovery Liquid Pipe (Main Line) in. 1/2 1/2 5/8 5/8 Suction Gas Pipe (Main Line) in. 1-1/8 1-1/8 1-1/8 1-1/8 Refrigerant Piping Discharge Gas Pipe (Main Line) in. N/A 7/8 N/A 7/8 Vertical Pipe Length (if unit is below FCU) ft. 164 (130) 164 (130) Actual Pipe Length (Equivalent Length) ft. 390 (459) 390 (459) Total Pipe Length ft. 980 980 Standard Connectable Indoor Unit Ratio % 50 - 130 50 - 130 Connection Ratio Maximum Number of Indoor Units Qty. 20 20 BPHE Inlet Pipe (Female Thread) in. 2 x (1-1/4 FPT) 2 x (1-1/4 FPT) BPHE Outlet Pipe (Female Thread) in. 2 x (1-1/4 FPT) 2 x (1-1/4 FPT) Drain Pipe (Female Thread) in. 2 x (1/2 FPS) 2 x (1/2 FPS) Water Side (Standard) Maximum System Water Pressure (BPHE) psi 285 285 Standard Inlet Water Temperature Range F 50 - 113 50 - 113 Recommended Inlet Water Flow Rate per Module (min.)* gpm 16.4 ~ 39.5 (13.2) 16.4 ~ 39.5 (13.2) Inlet Water Temperature Range Cooling** F 27 (34***) - 113 27 (34***) - 113 Water Side Inlet Water Temperature Range Heating F 14 - 113 14 - 113 (Geothermal) Water Flow Rate gpm 21 - 40 21 - 40 Weight lbs. 2 x 330 2 x 330 Unit Dimensions (H x W x D) in. 39-3/8 x (30-3/4 x 2) x 21-11/16 Voltage Range (min - max) V/ph/Hz 414 - 506 414 - 506 Maximum Overcurrent Protection (MOP) A 15 + 15 15 + 15 Electrical Minimum Circuit Amps (MCA) A 10.2 + 10.2 10.2 + 10.2 Compressor Rated Load Amps (RLA) A 5.3 + 5.3 7.0 + 7.0 Compressor Type Daikin G-Type Scroll Daikin G-Type Scroll Compressor Compressor Set-Up 1 INV + 1 INV 1 INV + 1 INV Compressor Capacity Control % 11 - 100 11 100 1 Indoor temp. : 80FDB, 67FWB/inlet water temp. : 85F/outlet water temp. : 95F Equivalent piping length : 25ft, level difference : 0ft. 2 Indoor temp. : 70FDB, 60FWB/inlet water temp. : 70F/Equivalent piping length : 25ft, level difference : 0ft. * Please note that a water strainer is required for each condensing unit model and now must be field supplied (strainer specification = 50 mesh). ** Application rules apply below 48F. Please contact your local Daikin office for design assistance and approval. *** The minimum cooling EWT is 34F when the condensing unit is located below the indoor units.
52
TripleModuleSystem460V
RWEYQ_PYDN
Amodular,energysavingandreliablealternativeto centralizedequipment. Keyfeaturesinclude: Compactlightweightcasingat393/8inheightand 330lbs.inweight Smallcondenserscanbestackedforreduced installationspaceandincreasedusablesquare footage Largersinglesystemcapacityandmodularconcept ensureswiderapplicationrangeforsatisfyingfloor byfloorloadsofcommercialbuildings AsstandardVRVWIIIcanoperatewithcondenser watertemperaturesdownto50Fbutthiscanbe extendedtoanindustryleading14Finheating
18 Ton
21 Ton
Name RWEYQ216PYDN RWEYQ252PYDN Combination 3 x RWEYQ72PYDN 3 x RWEYQ84PYDN Cooling Capacity Btu/h 216,000 252,000 Cooling Input Power kW 12.6 16.8 Heating Capacity Btu/h 243,000 283,500 Performance Heating Input Power kW 12.0 16.2 Power V/ph/Hz 460/3/60 Sound Pressure Level @ 3ft. dB(A) 56 57 System Configuration Heat Pump Heat Recovery Heat Pump Heat Recovery Liquid Pipe (Main Line) in. 5/8 5/8 3/4 3/4 Suction Gas Pipe (Main Line) in. 1-3/8 1-3/8 1-3/8 1-3/8 Refrigerant Piping Discharge Gas Pipe (Main Line) in. N/A 1-1/8 N/A 1-1/8 Vertical Pipe Length (if unit is below FCU) ft. 164 (130) 164 (130) Actual Pipe Length (Equivalent Length) ft. 390 (459) 390 (459) Total Pipe Length ft. 980 980 Standard Connectable Indoor Unit Ratio % 50 - 130 50 - 130 Connection Ratio Maximum Number of Indoor Units Qty. 22 22 BPHE Inlet Pipe (Female Thread) in. 3 x (1-1/4 FPT) 3 x (1-1/4 FPT) BPHE Outlet Pipe (Female Thread) in. 3 x (1-1/4 FPT) 3 x (1-1/4 FPT) Drain Pipe (Female Thread) in. 3 x (1/2 FPS) 3 x (1/2 FPS) Water Side (Standard) Maximum System Water Pressure (BPHE) psi 285 285 Standard Inlet Water Temperature Range F 50 - 113 50 - 113 Recommended Inlet Water Flow Rate per Module (min.)* gpm 16.4 ~ 39.5 (13.2) 16.4 ~ 39.5 (13.2) Inlet Water Temperature Range Cooling** F 27 (34***) - 113 27 (34***) - 113 Water Side Inlet Water Temperature Range Heating F 14 - 113 14 - 113 (Geothermal) Water Flow Rate gpm 21 - 40 21 - 40 Weight lbs. 3 x 330 3 x 330 Unit Dimensions (H x W x D) in. 39-3/8 x (30-3/4 x 3) x 21-11/16 Voltage Range (min - max) V/ph/Hz 414 - 506 414 - 506 Maximum Overcurrent Protection (MOP) A 15 + 15 + 15 15 + 15 + 15 Electrical Minimum Circuit Amps (MCA) A 10.2 + 10.2 + 10.2 10.2 + 10.2 + 10.2 Compressor Rated Load Amps (RLA) A 5.3 + 5.3 + 5.3 7.0 + 7.0 + 7.0 Compressor Type Daikin G-Type Scroll Daikin G-Type Scroll Compressor Compressor Set-Up 1 INV + 1 INV + 1 INV 1 INV + 1 INV + 1 INV Compressor Capacity Control % 8 - 100 8 - 100 1 Indoor temp. : 80FDB, 67FWB/inlet water temp. : 85F/outlet water temp. : 95F Equivalent piping length : 25ft, level difference : 0ft. 2 Indoor temp. : 70FDB, 60FWB/inlet water temp. : 70F/Equivalent piping length : 25ft, level difference : 0ft. * Please note that a water strainer is required for each condensing unit model and now must be field supplied (strainer specification = 50 mesh). ** Application rules apply below 48F. Please contact your local Daikin office for design assistance and approval. *** The minimum cooling EWT is 34F when the condensing unit is located below the indoor units.
VRV
53
InstallationSpace
Standardsuppliedaccessories
Confirmthefollowingaccessoriesareincluded.The storagelocationoftheaccessoriesisshowninfigure1. (Refertofigure1) 1. Clamps,Manuals,etc. 2. Accessorypipes
InstallationSpaceExamples
Theinstallationspacerequirementshowninfigure2is areferenceforcooling. Duringinstallation,installtheunitsusingthemost appropriateofthepatternsshowninfigure2forthe locationinquestion,takingintoconsiderationhuman trafficandwind. Ifthenumberofunitsinstalledismorethanthat showninthepatterninfigure2,installtheunitsso thatthereisnoairshortcircuiting. Asregardstospaceinfrontoftheunit,considerthe spaceneededfortherefrigerantpipingwheninstalling theunits,asdeterminedbylocalcodes. Ifthespacerequirementsinfigure2donotapply, contactyourcontractororDaikindirectly. (Refertofigure2) 1. Frontside 2. Nolimittowallheight 3. Servicespaceoffrontside 4. Servicespaceofsuctionside ForPatterns1and2infigure2: Wallheightforfrontside nohigherthan59in. Wallheightonthesuctionside nohigherthan 195/8in. Wallheightforsides nolimit. Iftheaboveheightisexceeded,calculateh1andh2 showninthefigurebelow,andaddh2/2totheservice spaceoffrontsideandh1/2totheservicespaceof suctionside.
54
InstallationSpace
Obstacleonbothsides
VRV
55
VRVIndoorUnits
Daikinoffersawideselectionofductedandductfreeunitsincapacitiesfrom7,500Btu/hto96,000 Btu/h.Designedforabsolutecomfortandversatilitywithasleekandsophisticateddesign,indoor unitsprovidezoningflexibilityandcomfortcontrolforalmostanyapplication.
Wall Mounted:FXAQ
Stylishandcompact,wall mountedunitsblend discreetlyintoanyinterior design.Availableincapacitiesupto24,000Btu/h,units areidealforsmallerzoneapplicationssuchasretail, offices,hotelrooms,andmultifamilyresidences.
CeilingMountedCassette:FXZQandFXFQ
Designedforcustomizable comfort, ceilingmounted cassettesareavailableintwo styles.TheFXZQprovidesup toafourwayairflowoption withquietsoundlevelsaslow as29dB(A).Designedtofitinastandard2x2ceiling grid,theseunitsareidealforsmallerroomapplications. TheFXFQroundflowcassettefeatures23configurable airflowdistributionpatterns,minimizingvariancesin temperatureandairflow discomfort.Thismodelisa greatfitforopenplan applications,andprovides supremeidealdistributionand maximumcomfortcontrol.
CeilingSuspended:FXHQ
Slimandelegantindesign, theceilingsuspendedunit featureswideairopenings andaninnovativesiroccofan forcomfortableairflowand quietoperation.Agreatfitforanylightcommercialspace, thisindoorunitisidealforretailstores,restaurants, classrooms,andconferencerooms.
FloorStanding:FXNQandFXLQ
Durableandversatile,floor standingunitscanbeeasily installedconcealed(FXNQ)or exposed(FXLQ)alonga perimeterwall.Builtwitha spacesavingdesignin capacitiesfrom12,000Btu/h to24,000Btu/h,these indoorunitsofferabalance ofcomfortandvisualappeal forchurches,classrooms, hospitalrooms,officehallways,andsimilarspaces.
ConcealedCeilingUnit:FXDQandFXMQ
Powerfulandcompact, concealedceilingunitsare availableinlowprofile(FXDQ) andmediumtohighstatic styles(FXMQ_M&FXMQ_P).Sliminheightforconcealed, abovetheceilinginstallation,indoorunitsofferdesign flexibilitywithductedcapabilities.Designedforapplications whereceilingspaceislimitedorwhereahiddensolutionis desired,theseindoorstylesareperfectforresidential applications,hotels,schools,officebuildings,andchurches.
OutsideAir:VAMandFXMQ_MF
Efficientwithsuperior performance,theERVis designedtomaintaingood indoorairqualityby providingsufficientlevelsof freshoutsideairandrecoveringwasteheatfrom extractedairleavingtheconditionedzone.Thisindoor unithasuniquefeaturessuchasindependentoperation, theabilitytointerlockwithotherHVACsystemsand automaticnightpurgetoreducecoolingloadsand increaseenergysavings.TheFXMQ_MFindoorunit providesbothfreshair treatmentandheatingand coolingcapabilitiesinasingle system.Easilyconnectedto Daikinfancoilunits,the100%outsideairprocessingunit canbeconnectedtothesamerefrigerantlinefordesign flexibilityandreducedsystemcost.
VerticalAirHandlingUnit:FXTQ
Intelligentandenergysaving,theFXTQis designedforatticandclosetapplications. Integratedwithanelectronicexpansion valve,printedcircuitboards,andanECM motor,indoorunitsofferenergy efficiencywithinstallationease.Upflow andhorizontalrightconfigurationswith capacitiesrangingfrom12,000Btu/hto 54,000Btu/hprovidedesignflexibilityfor retrofitandnewconstruction applications.
56
Capacity (kbtu/h)
7.5
12
18
24
30
36
42
48
54
72
96
Ductfree
CeilingSuspendedUnit FXHQ_MVJU
FloorStandingUnit FXLQ_MVJU9 ConcealedFloor StandingUnit FXNQ_MVJU9 VerticalAirHandlingUnit FXTQ_PAVJU DCDuctedConcealedCeiling Unit(MediumtoHighStatic) FXMQ_PVJU ConcealedCeilingUnit (MediumtoHighStatic) FXMQ_MVJU SlimDuctBuiltin ConcealedCeilingUnit FXDQ_MVJU 100%OutsideAir ProcessingUnit FXMQ_MFVJU EnergyRecoveryVentilator VAM_GVJU
Ducted
Ventilation
VRV
Availablein300,470,600,and1200CFM
57
RoundFlowCassette
FXFQ_PVJU
BRC1E72 (Option)
BRC2A71 (Option)
Customizablecomfortinanelegantdesign.
Keyfeaturesandbenefits: 360 airflowtoreducedraftsandimprovecomfort Modelsrangefrom9MBHto48MBH Improvedflexibilitywith23differentpossibleairflow patterns,ensuringidealairdistributiontomaximize comfortandsavings Lowerairvelocitiesforbetterroomairflow distribution Reducedunitweightandimprovedefficiencywitha lightweightfan Stainresistantandeasilycleanabledecorationpanel coating Condensatepumpwithverticalliftofupto331/2 includedasstandard FXFQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate HH/H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure HH/H/L Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish Protection Devices Recommended Fuse/Breaker Kit Model DACA-FQP13-1K A Indoor Units FXFQ09-48PVJU 15 15 V/ph/Hz Btu/h Btu/h
0.75 Ton
FXFQ09PVJU 9,500 10,500 R-410A 460/390/350 43 9-11/16 33-1/16 33-1/16 30/28/27 1-1/4 33-1/2 1/4 (Flare) 1/2 (Flare)
1.0 Ton
FXFQ12PVJU 12,000 13,500 R-410A 460/390/350 43 9-11/16 33-1/16 33-1/16 30/28/27 1-1/4 33-1/2 1/4 (Flare) 1/2 (Flare)
1.5 Ton
FXFQ18PVJU
2.0 Ton
2.5 Ton
3.0 Ton
FXFQ36PVJU 36,000 40,000 R-410A 1,180/910/700 55 11-5/16 33-1/16 33-1/16 44/38/32 1-1/4 33-1/2 3/8 (Flare) 5/8 (Flare)
4.0 Ton
FXFQ48PVJU 48,000 54,000 R-410A 1,220/970/790 55 11-5/16 33-1/16 33-1/16 45/40/34 1-1/4 33-1/2 3/8 (Flare) 5/8 (Flare)
cfm lbs. in. in. in. dB(A) in. O.D. in. in. in.
FXFQ24PVJU FXFQ30PVJU 208-230/1/60 18,000 24,000 30,000 20,000 27,000 34,000 R-410A R-410A R-410A Electronic Expansion Valve 560/470/390 780/620/470 830/670/530 43 48.5 48.5 9-11/16 9-11/16 9-11/16 33-1/16 33-1/16 33-1/16 33-1/16 33-1/16 33-1/16 32/30/27 36/32/28 38/35/31 1-1/4 1-1/4 1-1/4 33-1/2 33-1/2 33-1/2 1/4 (Flare) 3/8 (Flare) 3/8 (Flare) 1/2 (Flare) 5/8 (Flare) 5/8 (Flare) Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15 15
15
15
MERV 13 Filter Kit Option contains a MERV 13 filter, adapter frame and easy to follow installation instructions and can be installed on the following models only:
InstallationSpace
58
2x24WayCassette
FXZQ_M(7)VJU(9)
BRC1E72 (Option)
Compact,customizablecomfort.
Keyfeaturesandbenefits: Soundpressurelevelsaslowas29dB(A) Spacesavingdepthofunitsrequiresonly11.6of ceilingspace Threeautoswingpositionstochoosefrom standard,draftpreventionandceilingstain prevention Simpleinstallationwithaneasytofitdecoration panelandeasyheightadjustment Easytocleangrille,washablelonglifefilter Condensatepumpwithverticalliftofupto211/2 includedasstandard
FXZQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish Protection Devices Recommended Fuse/Breaker A V/ph/Hz Btu/h Btu/h
0.6 Ton
FXZQ07M(7)VJU(9) 7,500 8,700 R-410A 320/247 42 11-1/4 22-5/8 22-5/8 31/29 1-1/32 21-1/2 1/4 (Flare) 1/2 (Flare)
0.75 Ton
1.0 Ton
1.5 Ton
FXZQ18M(7)VJU(9) 18,000 21,000 R-410A 495/353 42 11-1/4 22-5/8 22-5/8 41/34 1-1/32 21-1/2 1/4 (Flare) 1/2 (Flare)
cfm lbs. in. in. in. dB(A) in. O.D. in. in. in.
15
FXZQ09M(7)VJU(9) FXZQ12M(7)VJU(9) 208-230/1/60 9,500 12,000 11,100 14,000 R-410A R-410A Electronic Expansion Valve 320/247 335/265 42 42 11-1/4 11-1/4 22-5/8 22-5/8 22-5/8 22-5/8 33/29 41/34 1-1/32 1-1/32 21-1/2 21-1/2 1/4 (Flare) 1/4 (Flare) 1/2 (Flare) 1/2 (Flare) Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15
15
InstallationSpace
VRV
59
WallMountedUnit
FXAQ_PVJU
BRC1E72 (Option)
Stylishlycompactdesignforanyinteriordcor.
Keyfeaturesandbenefits: Autoswingmechanismensuresefficientair distributionvialouversthatautomaticallyclosewhen theunitisturnedoff Wideairdischargeoutletdistributesacomfortable airflowthroughouttheentirespace Horizontallouversandfrontpanelcanbeeasily removedforcleaning Drainpipecanbeeasilyhiddenfromsight Filterincluded Modelsrangefrom7.5MBHto24MBH
FXAQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Liquid Pipe Connections Gas External Finish Protection Devices Recommended Fuse/Breaker A V/ph/Hz Btu/h Btu/h
0.6 Ton
FXAQ07PVJU 7,500 8,500 R-410A 260/160 26 11-3/8 31-1/4 9-1/4 36/31 11/16 1/4 (Flare) 1/2 (Flare)
0.75 Ton
FXAQ09PVJU 9,500 10,500 R-410A 280/175 26 11-3/8 31-1/4 9-1/4 37/31 11/16 1/4 (Flare) 1/2 (Flare)
1.0 Ton
1.5 Ton
2.0 Ton
FXAQ24PVJU 24,000 26,500 R-410A 635/470 31 11-3/8 41-3/8 9-1/4 47/40 11/16 3/8 (Flare) 5/8 (Flare)
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
15
15
FXAQ12PVJU FXAQ18PVJU 208-230/1/60 12,000 18,000 13,500 20,000 R-410A R-410A Electronic Expansion Valve 300/180 500/400 26 31 11-3/8 11-3/8 31-1/4 41-3/8 9-1/4 9-1/4 38/31 43/37 11/16 11/16 1/4 (Flare) 1/4 (Flare) 1/2 (Flare) 1/2 (Flare) Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15
15
InstallationSpace
60
CeilingSuspendedUnit
FXHQ_MVJU
BRC1E72 (Option)
BRC2A71 (Option)
BRC7E83 (Option)
Comfortableairflowinaslimdesign.
Keyfeaturesandbenefits: Oneofourslimmestindoorunits(lessthan8)fits withinanyinteriordesign Wideairdischargeoutletdistributesacomfortable airflowthroughouttheentirespace Innovativesiroccofantechnologykeepssound pressurelevelslow Installationisfastandoptionaldrainupkitcanbe addedeasily Bristlefree,nondewflapandflatdesignmake cleaningsimple Longlifefilterprovidedasstandard Modelsrangefrom12MBHto36MBH
FXHQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Pipe Connections External Finish Protection Devices Recommended Fuse/Breaker A Liquid Gas V/ph/Hz Btu/h Btu/h
1.0 Ton
FXHQ12MVJU 12,000 13,500 R-410A 410/340 55 7-11/16 37-13/16 26-3/4 42/33 1 (Flare) 1/4 (Flare) 1/2 (Flare)
2.0 Ton
FXHQ24MVJU 208-230/1/60 24,000 27,000 R-410A Electronic Expansion Vavle 710/600 80 7-1/16 55-1/8 26-3/4 44/36 1 (Flare) 3/8 (Flare) 5/8 (Flare) White Casing Fuse Fan Motor Thermal Protector 15
3.0 Ton
FXHQ36MVJU 36,000 40,000 R-410A 830/670 90 7-11/16 62-5/8 26-3/4 46/41 1 (Flare) 3/8 (Flare) 5/8 (Flare)
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
15
15
InstallationSpace
VRV
61
FloorStanding
FXLQ_MVJU9
BRC1E72 (Option)
BRC2A71 (Option)
BRC4C82 (Option)
Balancedairflowinaspacesavingdesign.
Keyfeaturesandbenefits: Idealforinstallationbeneathawindow Unitrequires minimalinstallationspace Fittedwithawashablelonglifefilter Remotecontrolleroptionsavailable Spacesavingunitcanbefreestandingorwall mounted,concealedorexposed Filterincluded Modelsrangefrom12MBHto24MBH
FXLQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Pipe Connections External Finish Protection Devices Recommended Fuse/Breaker A Liquid Gas V/ph/Hz Btu/h Btu/h
1.0 Ton
FXLQ12MVJU9 12,000 13,500 R-410A 280/210 66 23-5/8 44-7/8 8-3/4 36/33 27/32 1/4 (Flare) 1/2 (Flare)
1.5 Ton
FXLQ18MVJU9 208-230/1/60 18,000 20,000 R-410A Electronic Expansion Vavle 490/380 80 23-5/8 55-7/8 8-3/4 40/35 27/32 1/4 (Flare) 1/2 (Flare) Ivory White Casing Fuse Fan Motor Thermal Protector 15
2.0 Ton
FXLQ24MVJU9 24,000 27,000 R-410A 560/420 80 23-5/8 55-7/8 8-3/4 41/36 27/32 3/8 (Flare) 5/8 (Flare)
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
15
15
InstallationSpace
PlanView SideView
62
ConcealedFloorStanding
FXNQ_MVJU9
BRC1E72 (Option)
Hiddendesignforminimalinstallationspace.
Keyfeaturesandbenefits: Idealforinstallationbeneathawindow Unitrequires minimalinstallationspace Fittedwithawashablelonglifefilter Remotecontrolleroptionsavailable Spacesavingunitcanbefreestandingor wallmountedandconcealed Outsideairintegrationpossible Filterincluded Modelsrangefrom12MBHto24MBH
FXNQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L Unit Condensate Connection Pipe Connections External Finish Protection Devices Recommended Fuse/Breaker A Liquid Gas V/ph/Hz Btu/h Btu/h
1.0 Ton
FXNQ12MVJU9 12,000 13,500 R-410A 280/210 51 24 42-1/8 8-5/8 36/33 27/32 1/4 (Flare) 1/2 (Flare)
1.5 Ton
FXNQ18MVJU9 208-230/1/60 18,000 20,000 R-410A Electronic Expansion Vavle 490/380 60 24 53-1/8 8-5/8 40/35 27/32 1/4 (Flare) 1/2 (Flare) Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15
2.0 Ton
FXNQ24MVJU9 24,000 27,000 R-410A 560/420 60 24 53-1/8 8-5/8 41/36 27/32 3/8 (Flare) 5/8 (Flare)
cfm lbs. in. in. in. dB(A) in. O.D. in. in.
15
15
InstallationSpace
VRV
A (in.) 28 39 39
B (in.) 46 57 57
63
VerticalAirHandlingUnit
FXTQ_PAVJU
BRC1E72 (Option)
BRC2A71 (Option)
BRC4C82 (Option)
Compactsolutionwithpowerfulcapabilities.
Keyfeaturesandbenefits: ReducedinstallationtimewithintegratedElectronic ExpansionValveandPrintedCircuitBoards Improvedapplicationflexibilitywiththeabilitytomix andmatchwithotherDaikinindoorunitsonthesame system Reducedpipingcostwithsmallerpipingdiameters Onlyupflowandhorizontalrightinstallationis permitted Improvedusercomfortwith2selectablefanspeeds (HandL) NewfanAutologicallowingtheunittobe commissionedwherethefanoperationwillcycleon andoffwiththeload TheECMfanmotorasstandardcontributestothe increaseinenergyefficiency,reductioninsoundand increasedESP(upto0.5W.G.)
FXTQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure Range Unit Condensate Connection Liquid Pipe Connections Gas External Finish Protection Devices Recommended Fuse/Breaker A V/ph/Hz Btu/h Btu/h
1.0 Ton
1.5 Ton
2.0 Ton
2.5 Ton
3.0 Ton
3.5 Ton
4.0 Ton
4.5 Ton
cfm lbs. in. in. in. dB(A) in. W.G. in. O.D. in. in.
FXTQ12PAVJU FXTQ18PAVJU FXTQ24PAVJU FXTQ30PAVJU FXTQ36PAVJU FXTQ42PAVJU FXTQ48PAVJU FXTQ54PAVJU 208-230/1/60 12,000 18,000 24,000 30,000 36,000 42,000 48,000 54,000 13,500 20,000 27,000 34,000 40,000 47,000 54,000 60,000 R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Electronic Expansion Valve 400/280 600/420 800/560 1,000/700 1,200/840 1,400/980 1,600/1,120 1,800/1,260 121 121 145 145 149 169 169 169 46-3/4 46-3/4 53-1/4 53-1/4 53-1/4 53-1/4 53-1/4 53-1/4 19-1/2 19-1/2 22 22 22 22 22 22 22 22 24 24 24 24 24 24 n/a n/a n/a n/a n/a n/a n/a n/a up to 0.50 3/4 1/2 (Braze) 1/4 (Braze) up to 0.50 3/4 1/2 (Braze) 1/4 (Braze) up to 0.50 up to 0.50 up to 0.50 up to 0.50 up to 0.50 3/4 5/8 (Braze) 3/8 (Braze) up to 0.50 3/4 5/8 (Braze) 3/8 (Braze)
3/4 3/4 3/4 3/4 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 5/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) 3/8 (Braze) Fully insulated, painted steel cabinet with gray finish Fuse Fan Motor Thermal Protector 15 15 15 15
15
15
15
15
InstallationSpace
64
DCDuctedConcealed
FXMQ_PVJU
BRC1E72 (Option)
BRC2A71 (Option)
BRC4C82 (Option)
Powerfulsystemwithaconcealeddesign.
Keyfeaturesandbenefits: Availablefrom7.5MBHto48MBH ImprovedefficiencywithDCfanmotor AutoadjustingairflowatcommissioningbasedonESP MediumESPcapabilitiesofupto0.8W.G. Threeuserselectedfanspeedsavailableplusfan Autologic Lowprofiledesign lessthat12high Builtincondensatepumpwithverticalliftofupto 183/8 MERV13filteroptionforindoorairquality
FXMQ_P Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure H/L Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish Protection Devices Recommended Fuse/Breaker A V/ph/Hz Btu/h Btu/h
0.6 Ton
FXMQ07PVJU 7,500 8,500 R-410A 317/264/229 55 11-13/16 21-5/8 27-9/16 33/29 0.40/0.12 1-1/4 18-3/8 1/4 (Flare) 1/2 (Flare)
0.75 Ton
FXMQ09PVJU 9,500 10,500 R-410A 317/264/229 55 11-13/16 21-5/8 27-9/16 33/29 0.40/0.12 1-1/4 18-3/8 1/4 (Flare) 1/2 (Flare)
1.0 Ton
FXMQ12PVJU 12,000 13,500 R-410A 335/282/246 55 11-13/16 21-5/8 27-9/16 34/29 0.40/0.12 1-1/4 18-3/8 1/4 (Flare) 1/2 (Flare)
1.5 Ton
2.0 Ton
2.5 Ton
FXMQ30PVJU 30,000 34,000 R-410A 882/794/706 80 11-13/16 39-3/8 27-9/16 43/39 0.80/0.20 1-1/4 18-3/8 3/8 (Flare) 5/8 (Flare)
3.0 Ton
FXMQ36PVJU 36,000 40,000 R-410A 1,130/953/812 102 11-13/16 55-1/8 27-9/16 43/39 0.80/0.20 1-1/4 18-3/8 3/8 (Flare) 5/8 (Flare)
4.0 Ton
FXMQ48PVJU 48,000 54,000 R-410A 1,377/1,165/988 102 11-13/16 55-1/8 27-9/16 44/40 0.80/0.20 1-1/4 18-3/8 3/8 (Flare) 5/8 (Flare)
cfm lbs. in. in. in. dB(A) in. W.G. in. O.D. in. in. in.
15
15
15
FXMQ18PVJU FXMQ24PVJU 208-230/1/60 18,000 24,000 20,000 27,000 R-410A R-410A Electronic Expansion Valve 635/582/529 688/618/565 80 80 11-13/16 11-13/16 39-3/8 39-3/8 27-9/16 27-9/16 41/37 42/38 0.80/0.20 0.80/0.20 1-1/4 1-1/4 18-3/8 18-3/8 1/4 (Flare) 3/8 (Flare) 1/2 (Flare) 5/8 (Flare) Galvanized Steel Plate Fuse Fan Driver Overload Protector 15 15
15
15
15
MERV 13 Filter Kit Option contains a MERV 13 filter, adapter frame and easy to follow installation instructions and can be installed on the following models only:
Kit Model DACA-FXMQ12-13-1K DACA-FXMQ30-13-1K DACA-FXMQ48-13-1K Indoor Unit FXMQ07-12PVJU FXMQ18-30PVJU FXMQ36-48PVJU
VRV
InstallationSpace
65
ConcealedCeilingUnit
FXMQ_MVJU
BRC1E72 (Option)
BRC2A71 (Option)
BRC4C82 (Option)
Hiddensystemforopenspacefloorplans.
Keyfeaturesandbenefits: Greaterdesignflexibilitywithacapacityrange extendedto96MBH Improvedductworkandfiltrationflexibilitywithhigh CFMandESPcapabilitiesofupto1.1W.G. Lowprofiledesignoflessthan19hightoreduce requiredinstallationspace AbilitytoconnectafloatswitchonthePCB MERV8andMERV13filteroptions
FXMQ_M Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure H/L Unit Condensate Connection Pipe Connections External Finish Protection Devices Recommended Fuse/Breaker MERV Filter Kit Option
Kit Model DACA-MQ96M-8-1K (MERV 8 Filter) DACA-MQ96M-13-1K (MERV 13 Filter) Indoor Units FXMQ72-96MVJU
6.0 Ton
FXMQ72MVJU V/ph/Hz Btu/h Btu/h 208-230/1/60 72,000 81,000 R-410A Electronic Expansion Valve cfm lbs. in. in. in. dB(A) in. W.G. in. O.D. in. in. 2,047/1,764 55 18-1/8 54-3/8 43-5/16 48/45 0.38/0.95 1 3/8 (Flare) 3/4 (Flare)
8.0 Ton
FXMQ96MVJU 96,000 108,000 R-410A 2,541/2,188 55 18-1/8 54-3/8 43-5/16 48/45 0.43/0.95 1 3/8 (Flare) 7/8 (Flare)
Liquid Gas
InstallationSpace
66
SlimDuctConcealed
FXDQ_MVJU
BRC1E72 (Option)
BRC2A71 (Option)
BRC4C82 (Option)
Lowprofiledesignforlimitedceilingspace.
Keyfeaturesandbenefits: Slimheight,atonly77/8,makesitsuitableformost oftheapplicationswhereattic/bulkheadspaceis limited Withasoundlevelaslowas29dB(A)forthe7.5,9or 12MBHindoorunit,theseunitsareamongthe quietestintheindustry Factorysetrearsuction;bottomsuctionconfiguration ispossible Washablefilterincluded Condensatepumpwithverticalliftofupto215/8 includedasstandard Blendsunobtrusivelywithanyinteriordecor;onlythe suctionanddischargegrillsarevisible
FXDQ Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Refrigerant Refrigerant Control Airflow Rate H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/L External Static Pressure H/L Unit Condensate Connection Condensate Pump Lift Liquid Pipe Connections Gas External Finish Protection Devices Recommended Fuse/Breaker A V/ph/Hz Btu/h Btu/h
0.6 Ton
FXDQ07MVJU 7,500 8,500 R-410A 280/226 51 7-7/8 27-9/16 24-7/16 33/29 0.12/0.04 1-1/32 21-5/8 1/4 (Flare) 1/2 (Flare)
0.75 Ton
FXDQ09MVJU 9,500 10,500 R-410A 280/226 51 7-7/8 27-9/16 24-7/16 33/29 0.12/0.04 1-1/32 21-5/8 1/4 (Flare) 1/2 (Flare)
1.0 Ton
1.5 Ton
2.0 Ton
FXDQ24MVJU 24,000 27,000 R-410A 580/460 71 7-7/8 43-5/16 24-7/16 36/32 0.17/0.06 1-1/32 21-5/8 3/8 (Flare) 5/8 (Flare)
cfm lbs. in. in. in. dB(A) in. W.G. in. O.D. in. in. in.
15
15
FXDQ12MVJU FXDQ18MVJU 208-230/1/60 12,000 18,000 13,500 20,000 R-410A R-410A Electronic Expansion Valve 280/226 440/350 51 63 7-7/8 7-7/8 27-9/16 35-7/16 24-7/16 24-7/16 33/29 35/31 0.12/0.04 0.17/0.06 1-1/32 1-1/32 21-5/8 21-5/8 1/4 (Flare) 1/4 (Flare) 1/2 (Flare) 1/2 (Flare) Galvanized Steel Plate Fuse Fan Motor Thermal Protector 15 15
15
InstallationSpace
VRV
67
100%OutsideAirUnit
FXMQ_MFVJU
BRC1E72 (Option)
Freshairtreatmentinamodularconcept designedtoalignwithVRVsystems.
Keyfeaturesandbenefits: CanbeconnectedtoallDaikinVRVSystems Availableinthreecapacities,nominal48,72and96 MBH Nominalairflowsare635,988,and1,236CFM respectively Externalstaticpressurecapabilitiesofupto1.03 W.G.allowsforflexibilitywithductworkandfiltration choices Alowprofiledesignofonly18.5highreducesthe requiredinstallationspaceandcaneliminate mechanicalroomsoradditionalstructuralsupports associatedwithtraditionalOAsystems IndoorAirQualityoptionsincludeMERV8and13 filtersandfilterboxes ConnectsdirectlyandseamlesslyintotheDaikinlocal andcentralizedcontrolsuite FXMQ_MF Specifications
Model Name Power Supply Cooling Capacity Heating Capacity Airflow Rate Unit Weight Unit Height Unit Width Unit Depth Sound Pressure External Static Pressure Pipe Connections External Finish Protection Devices Operating Range - Cooling Operating Range - Heating Discharge Air Temp - Cooling Discharge Air Temp - Heating F F F F Liquid Gas V/ph/Hz Btu/h Btu/h cfm lbs. in. in. in. dB(A) in. W.G. in. in.
4.0 Ton
FXMQ48MFVJU 48,000 30,000 635 190 18-1/2 29-1/4 43-5/16 42 0.88 3/8 (Flare) 5/8 (Flare)
6.0 Ton
FXMQ72MFVJU 208-230/1/60 72,000 47,000 988 271 18-1/2 54-3/8 43-5/16 47 0.96 3/8 (Flare) 3/4 (Brazing) Galvanized Steel Plate Fuse Fan Motor Thermal Protector 66 DB/59 WB - 109 DB/90 WB 23 DB to 68 DB 55 - 77 64 - 86
8.0 Ton
FXMQ96MFVJU 96,000 59,000 1,236 271 18-1/2 54-3/8 43-5/16 47 1.03 3/8 (Flare) 7/8 (Brazing)
Indoor Units
FXMQ48MFVJU FXMQ72-96MFVJU FXMQ48MFVJU FXMQ72-96MFVJU
InstallationSpace
68
EnergyRecoveryUnit
VAM_GVJU
BRC1E72 (Option)
Improvedairqualitywithenergysavings.
Keyfeaturesandbenefits: Superiorperformancewithahighefficiencyfanand thecapabilityforuseinawiderangeofclimates (5to122FDBand80%RHorless) Uniquefunctionssuchasindependentoperation, interlockwithotherHVACsystemsandautomatic nightpurgetoreducecoolingloadsandincrease energysavings InterlockedsimultaneousoperationwithVRVindoor units Precooling/heatingcontrolfunctiontodelaythe startofventilationduringairconditionerstartupfor higherenergysavings Supplyandexhaustfreshupoperationmodesto controlpressurewithinaspace VAM Specifications
Model Name Temperature Recovery Efficiency Percentage Cooling Heating Cooling Heating 100 75 100 75 100 75 100 75 Airflow % % % % % % % % V/ph/Hz cfm lbs. in. in. in. dB(A) in. W.G. VAM300GVJU 65 70 65 69 40 48 57 63 300/300/170 300/300/170 71 12-1/16 34-5/8 31-1/2 37/33.5/25.5 0.64/0.26/0.16 45 50 59 65 208-230/1/60 470/470/390 600/600/500 470/470/390 600/600/500 121 148 15-1/4 15-1/4 43-11/16 43-11/16 32-3/4 47-13/16 42/38.5/35 42.5/39/36 0.73/0.39/0.33 0.76/0.34/0.32 Galvanized Steel Plate Self-Extinguishing Urethane Foam 10 10 5F ~ 122FDB 80% RH or less VAM470GVJU 68 72 66 VAM600GVJU 72 74 70 73 49 52 60 63 1,200/1,200/930 1,200/1,200/930 346 30-7/8 63-3/4 47-13/16 44.5/41.5/38.5 0.56/0.24/0.16 VAM1200GVJU
Enthalpy Recovery Efficiency Percentage Power Supply Airflow Rate HH/H/L Unit Weight Unit Height Unit Width Unit Depth Sound Pressure H/H/L External Static Pressure HH/H/L External Finish Insulation Material Connection Duct Diameter Ambient Conditions
in. A
14
VRV
69
VRVControls
OptimizedforVRVtechnology,Daikincontrolsprovidehighlyscalablesolutionsforall applicationsandbudgets.Fromsimplifiedcontrollerstocentralizedmanagementsystems, controlsoffercomfortcontrolinaneasilymanagedandoperatedsystem.
Project Requirements Daikin VRV Controls
BRC1E72 Navigation Simple individual zone control Independent Cool and Heat setpoints Individual zone control with weekly programmable scheduling Multi-zone control without scheduling functions Basic central point on/off control of all air handling units Advanced multi-zone control of small to medium size projects Advanced multi-zone control of large commercial projects Advanced multi-zone control with scheduling logic and calendar Automatic cooling/heating changeover for heat pump systems Single input batch shutdown of all connected air handlers Web browser control and monitoring via Intranet and Internet E-mail notification of system alarms and equipment malfunctions Multiple tenant power billing for shared condenser applications Temperature set-point range restrictions Graphical user interface with floor plan layout Start/stop control of ancillary building systems* Daikin VRV integration with BACnet based automation systems Daikin VRV integration with LonWorks based automation systems
*Requires one or more DEC102A51-US2 Digital Input/Output units.
BRC2A71 Simplified
BACnet Interface
LonWorks Interface
DCM601A71 64indoorunitgroups(128indoorunits) ManagementofDaikinunitsandancillaryequipment Touchscreendisplay BuiltinEthernetport,Webenabled(standard) Alarmemailfunction Floorplanlayout DCM601A72 iTMPlusAdapterincreasesiTMcontroltohaveanother64indoor unitgroups(128indoorunits) Upto512indoorunitgroups(1024indoorunits)canbedaisy chainedtotheiTMwiththeuseofupto7iTMPlusAdapters
NavigationRemoteController(BRC1E72)
TheNavigationRemoteControllerhasbeenimprovedtomeettheneedsofthegrowingVRVand SkyAirmarket.Thiscontrollerwillsatisfyalmostanycontrolsrequirement.Theconfigurabledisplay andoperationbuttonswillprovideasmuchoraslittlecontrolastheprojectrequires. Canbeusedwith: AllVRVindoorunitsandtheFAQ,FBQ,FCQ,FHQ,FTQSkyAirindoorunits
WeeklySchedule
GuideonDisplay
AllStatusonDisplay
English/French/Spanish LanguageSelectable
MaintenanceNotice
ErrorNotification
KeyFunctions Configurabledisplay Standard,Detailed,andSimple(improved) DualorsingleCoolandHeatsetpointsforoccupiedperiods(improved) Independentsetbacksetpointsforunoccupiedperiods Unwantedbuttons/operationmodescanbedisabled (improved) NEW optionalface Poweroffeliminatessetpointandmodeadjustment configurable(improved) decalstohide Setpointrangelimitation unnecessarybuttons Individualbuttonprohibits(improved) AutochangeoverforHeatRecoveryandHeatPumpsystemswithdualorsinglesetpoints(improved) AutomaticadjustmentforDaylightSavingsTime(DST)(improved) Schedule Weeklyschedule 7day,weekdayplusSaturdayandSunday(5+1+1),weekdayplusweekend(5+2) andEveryday(1)(improved) Allowsprogrammingupto5eventsperdaywithCoolandHeatorsinglesetpoints SetbackconfigurationwithCoolandHeatsetpoints Display Others Detaileddisplaymode Backlit Operationmode,Occupiedandunoccupiedsetpoint(s), Roomtemperaturesensor Fanspeed,Airflowdirection,Roomtemperature,Time,Day, 12/24hourclock andStatusdisplay Fahrenheit/Celsiusselectable Standarddisplaymode Operationmode,Occupiedandunoccupiedsetpoint(s),Fanspeed, English/French/Spanishselectable andStatusdisplay (buttonsandsystemstatusdisplayare Simpledisplaymode(new) inEnglishonly) Operationmode,Occupiedandunoccupiedsetpoint(s),Fanspeed, Remotecontrolgroup upto16 Roomtemperature indoorunits Facedecaloptiontohideunnecessarybuttons(new)
VRV
71
System Capabilities
Infrared Fonly
Upto16indoor units
Upto16indoor units
Autochangeover
Surely Change to Cooling Change to Cooling (with Guard Timer)
ConfigurableDisplayMode Detailed,Standard,Simple
DisplayMode
Displayimage
Detailed
Standard
SimpleNew
Cooling SP Heating SP
Change to Heating (with Guard Timer) Surely Change to Heating
On/OffstatusonLED (LEDblinkswhenanerrorisoccurred) Mode Setpoint(Dual/Single) Roomtemperature Fanspeed Airflowdirection (whenalouverisavailable) DayandTime Statusicon Keylockicon Errormessage
AutomaticchangeoverinHeatPumpandHeat
RecoverySystems At1oFabovecoolingor1oFbelowheating setpoint(default) Configurablebetween1oF 4oF(improved) Another1oFabovecoolingor1oFbelow heatingchangeoverpointsimmediate changeoverignoringguardtimer(new) Configurablebetween1oF 4oF(new) Guardtimertopreventfrequentmodechange 15,30,60(default),or90minuteguardtimer settable On/OffDisplayOption
X*3 X X
OptionalFaceDecals SingleSetpointFaceDecals
DualSetpointFaceDecals
72
VRVControls:DCS601C71
CentralizedandAdvanced VRVControl Upto64IndoorUnitGroups(128actualIndoorUnits)canbemonitored andcontrolledwithindividualCoolandHeatSetpoints,SetpointRange Limitation,SetbackSetpoints,andAutochangeovertomeetyour expectationsandprojectrequirements.Upto128IndoorUnitGroups (256actualIndoorUnits)canbemonitoredandcontrolledwiththe additionoftheOptionalDIIINetPlusAdapter(DCS601A72). Integratesand/orinterlockssensors,switches,dampers,fans,pumps,and lightingwithDaikinIndoorUnits. AllowsdailyremotemonitoringandcontrolwiththeWeb/EmailSoftware optionthatcanbeaccessedviathefacilitysLocalAreaNetworkoryour Internetconnection.SendsErrorEmailtomobiledevicewiththeoptional Web/EmailSoftwareoption(DCS004A71). Determinesenergyconsumptionofsharedcondensingunitsbasedupon tenant(IndoorUnit)demandwithoptionalPPDSoftwareoption (DCS002A71).
TenantBilling
VRV
73
VRVControls:DCM601A71
CentralizedandAdvanced VRVControl Upto64IndoorUnitGroups(128actualIndoorUnits)canbemonitored andcontrolledwithindividualCoolandHeatSetpoints,SetpointRange Limitation,SetbackSetpoints,andAutochangeovertomeetyour expectationsandprojectrequirements.Upto512IndoorUnitGroups (1024actualIndoorUnits)canbemonitoredandcontrolledwiththe additionofupto7optionaliTMPlusAdapters(DCM601A72). Integratesand/orinterlockssensors,switches,dampers,fans,pumps,and lightingwithDaikinIndoorUnits. AllowsdailyremotemonitoringandcontrolwiththeWeb/Emailfunction thatcanbeaccessedviathefacilitysLocalAreaNetworkoryourInternet connection.SendsErrorEmailtomobiledevicewiththeWeb/Email function (DCS004A71). Determinesenergyconsumptionofsharedcondensingunitsbasedupon tenant(IndoorUnit)demandwithoptionalPPDSoftwareoption (DCM002A71).
TenantBilling
Upto650managementpointscanbemanagedontheintelligentTouchManager
74
VRVAccessories
BranchSelectorBoxes
Providingflexibilityandminimizingmechanicalandelectricalinstallationcosts,single portbranchselectorboxescanconnectupto8indoorunitsandareidealforopenplan applicationswhereasmultiportbranchselectorboxesareidealforsmalltightly groupedroomswhichrequireindividualheatingandcoolingcontrol.
Branch Selector Units
Model Power Number of Branches Number of Connectable Units per Branch Weight Dimensions (H x W x D) Piping Connections Indoor Unit Outdoor Unit V/Ph/Hz BSVQ36PVJU 208-230/1/60 1 Max. 4 26 3/8 (Braze) 5/8 (Braze) 3/8 (Braze) 5/8 (Braze) 1/2 (Braze)
Single Port
BSQV60PVJU 208-230/1/60 1 Max. 8 26 8-1/8 x 15-1/4 x 12-13/16 3/8 (Braze) 5/8 (Braze) 3/8 (Braze) 5/8 (Braze) 1/2 (Braze) BSVQ96PVJU 208-230/1/60 1 Max. 8 33 3/8 (Braze) 7/8 (Braze) 3/8 (Braze) 7/8 (Braze) 3/4 (Braze)
Multi-Port
BSV4Q36PVJU 208-230/1/60 4 Max. 4 132 8-1/4 x 41-1/2 x 25 3/8 (Braze) 5/8 (Braze) 1/2 (Braze) 1-1/8 (Braze) 3/4 (Braze) BSV6Q36PVJU 208-230/1/60 6 Max. 4 196 8-1/4 x 62-1/8 x 25 3/8 (Braze) 5/8 (Braze) 5/8 (Braze) 1-1/8 (Braze) 1-1/8 (Braze)
lbs. in. Liquid in. Gas in. Liquid in. Suction Gas in. HP/LP Gas in.
REFNET
REFNETjointsdistributeanequalflowofrefrigerantineverybranchofthepipingnetwork.
VRVIII Heat Recovery - 208-230V and 460V
Unit Model Number REYQ72PB REYQ96PB REYQ120PB REYQ144PB REYQ168PB REYQ264PB REYQ288PB REYQ312PB REYQ336PB KHRP25M33H (max. 8 branches) KHRP25M72H (max. 8 branches) KHRP25M73HU (max. 8 branches) KHRP25A22T KHRP25A33T KHRP25M72TU KHRP25M73TU BHFP26P09U BHFP26P136U REYQ192PB REYQ216PB REYQ240PB RXYQ264PB RXYQ288PB RXYQ312PB RXYQ336PB RXYQ360PB KHRP26M22H (max. 4 branches) KHRP26M33H (max. 8 branches) KHRP26M72H (max. 8 branches) KHRP26M73HU (max. 8 branches) KHRP26A22T KHRP26A33T KHRP26M72TU KHRP26M73TU BHFP22P100U BHFP22P151U RXYQ192PB RXYQ216PB RXYQ240PB
REFNET Header
KHRP25M33H (max. 8 branches) KHRP25M72H (max. 8 branches) KHRP25A22T KHRP25A33T KHRP25M72TU BHFP26P09U
KHRP25A22T KHRP25A33T
REFNET Header
KHRP26M22H (max. 4 branches) KHRP26M33H (max. 8 branches) KHRP26M72H (max. 8 branches) KHRP26A22T KHRP26A33T KHRP26M72TU BHFP22P100U
VRVIII-S
RXYMQ36PVJU RXYMQ48PVJU
VRV
KHRP26A22T
Outdoor Unit Multi Piping Connection Kit (Heat Pump) Outdoor Unit Multi Piping Connection Kit (Heat Recovery)
75
WARNINGS: Alwaysusealicensedinstallerorcontractortoinstallthisproduct.Donottrytoinstall theproductyourself.Improperinstallationcanresultinwaterorrefrigerantleakage, electricalshock,fireorexplosion. UseonlythosepartsandaccessoriessuppliedorspecifiedbyDaikin.Askalicensed contractortoinstallthosepartsandaccessories.Useofunauthorizedpartsand accessoriesorimproperinstallationofpartsandaccessoriescanresultinwateror refrigerantleakage,electricalshock,fireorexplosion. ReadtheUsersManualcarefullybeforeusingthisproduct.TheUsersManual providesimportantsafetyinstructionsandwarnings.Besuretofollowthese instructionsandwarnings. Foranyinquiries,contactyourlocalDaikinsalesoffice.
Use of the AHRI Certified mark indicates a manufacturer's participation in the certification program. For verification of certification for individual products, go to www.ahridirectory.org
Daikin, and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, LTD.
Our continuing commitment to quality products may mean a change in specifications without notice.
2013
GCUSE13-07B