Diagnostic buffer of module CPU 412-2 DP Order No.

/ Description 6ES7 412-2XJ05-0AB0 - - Rack: Slot: Serial number: SVPV5401559 Event 1 of 12: Event ID 16# 4302 Mode transition from STARTUP to RUN Startup information: - Time for time stamp at the last non backed up power on - Single processor operation Current/last startup type: - Warm restart triggered by switch setting Permissibility of certain startup types: - Manual warm restart permitted Last valid operation or setting of automatic startup type at power on: - Warm restart triggered by switch setting Previous operating mode: STARTUP (warm restart) Requested operating mode: RUN Incoming event 06:22:47.135 AM 01/01/1994 Event 2 of 12: Event ID 16# 3922 BAF: backup voltage failure on central rack Requested OB: Power supply error OB (OB81) Priority class: 28 External error, Incoming event 06:22:47.134 AM 01/01/1994 Event 3 of 12: Event ID 16# 3921 BATTF: at least one backup battery failed on central rack Requested OB: Power supply error OB (OB81) Priority class: 28 External error, Incoming event 06:22:47.134 AM 01/01/1994 Event 4 of 12: Event ID 16# 1381 Request for manual warm restart STOP due to: Memory reset started automatically (power on not backed up ) Startup information: - Startup without modified system configuration - No difference between setpoint and actual configuration - Time for time stamp at the last non backed up power on - Single processor operation Current/last startup type: - Warm restart triggered by switch setting Permissibility of certain startup types: Component Hardware Firmware 0 2 Version 2 V 5.1.0

- Manual warm restart permitted Last valid operation or setting of automatic startup type at power on: - Warm restart triggered by switch setting Requested OB: Startup OB (OB100) Priority class: 27 Incoming event 06:22:46.086 AM 01/01/1994 Event 5 of 12: Event ID 16# 4301 Mode transition from STOP to STARTUP STOP due to: Memory reset started automatically (power on not backed up ) Startup information: - Time for time stamp at the last non backed up power on - Single processor operation Current/last startup type: - Warm restart triggered by switch setting Permissibility of certain startup types: - Manual warm restart permitted Last valid operation or setting of the automatic startup type at power on: - Warm restart triggered by switch setting Previous operating mode: STOP (internal) Requested operating mode: STARTUP (warm restart) Incoming event 06:22:46.058 AM 01/01/1994 Event 6 of 12: Event ID 16# 530D New startup information in STOP mode Startup prevented by: - Cold restart or warm restart necessary Startup information: - Time for time stamp at the last non backed up power on - Single processor operation Current/last startup type: - No startup type/following memory reset Permissibility of certain startup types: - Manual warm restart permitted Last valid operation or setting of automatic startup type at power on: - Warm restart triggered by switch setting Operating mode: STOP (internal) Incoming event 06:22:46.057 AM 01/01/1994 Event 7 of 12: Event ID 16# 5371 Distributed I/Os: End of the synchronization with a DP master/IO controller slot 2 Number of distributed stations: 21 Priority class: 23 Incoming event 06:18:33.704 AM 01/01/1994 Event 8 of 12: Event ID 16# 530D New startup information in STOP mode Startup prevented by: - STOP request exists - Keyswitch set to STOP - Cold restart or warm restart necessary

on

Startup information: - Time for time stamp at the last non backed up power on - Single processor operation Current/last startup type: - No startup type/following memory reset Permissibility of certain startup types: - Manual warm restart permitted Last valid operation or setting of automatic startup type at power on: - No startup type/following memory reset Operating mode: STOP (internal) Incoming event 06:18:33.504 AM 01/01/1994 Event 9 of 12: Event ID 16# 3921 BATTF: at least one backup battery failed on central rack Requested OB: Power supply error OB (OB81) OB not found, or disabled, or cannot be started in the in the current operating mode External error, Incoming event 06:18:33.498 AM 01/01/1994 Event 10 of 12: Event ID 16# 3922 BAF: backup voltage failure on central rack Requested OB: Power supply error OB (OB81) OB not found, or disabled, or cannot be started in the in the current operating mode External error, Incoming event 06:18:33.498 AM 01/01/1994 Event 11 of 12: Event ID 16# 430E Memory reset executed Initialization information: Memory reset due to backup power failure Previous operating mode: STOP (memory reset) Requested operating mode: STOP (own initialization) Incoming event 06:18:30.475 AM 01/01/1994 Event 12 of 12: Event ID 16# 4309 Memory reset started automatically (power on not backed up ) Initialization information: Memory reset due to backup power failure No relevance for user (Z1): 0001 Previous operating mode: No voltage Requested operating mode: STOP (memory reset) Incoming event 06:18:30.450 AM 01/01/1994

You might also like