Professional Documents
Culture Documents
PROJECT REPORT DESIGN AND CONSTRUCTION OF SHEAR WALLS A PROJECT REPORT SUBMITTED TO JNTU, HYD BACHELOR OF TECHNOLOGY IN CIVIL ENGINEERING BY K.BHASKER RAO A.KAMAL TEJ MD.BASEERUDDIN B.RAVI TEJA B.SANTHOSH REDDY 09241A0163 09241A0169 09241A0176 09241A0191 09241A01A1
DEPARTMENT OF CIVIL ENGINEERING GokarajuRangaraju Institute of Engineering & Technology Bachupally HYDERABAD-500 090
GRIET
Page 1
CERTIFICATE
This is to certify that project entitled DESIGN AND CONSTRUCTION OF SHEAR WALLS that is being submitted by K.BhaskerRao (09241A0163), A. Kamal Tej (09241A0169), Md. Baseeruddin (09241A0176), B. Ravi Teja (09241A0191), B.Santhosh Kumar Reddy (09241A01A1) in partial fulfillment of the requirement for the award of Degree of Bachelor of Technology in Civil Engineering and Technology ( Affiliated to Jawaharlal Nehru Technological University, Hyderabad) is a record of bonafide work carried out by them under my guidance and supervision. The results embodied in this thesis have not been submitted to any other University or Institute for the award of any degree.
GRIET
Page 2
ACKNOWLEDGEMENT
Success is epitome of hard work, congency for fulfilling the mission, indefatigable perseverance and most of all encouraging guidance and steering. We express our sincere thanks to, Dr. Jandhyala Murthy principal, GRIET for the support and motivation provided to us. It gives us immense pleasure to express our gratitude to Prof. Dr. G.VenkataRamana , Head of the department of Civil Engineering and all the faculty of civil engineering department ,for their esteemed guidance and able supervision during the course of project. Their constant encouragement and Co-operation made this project a success. It also gives us immense pleasure to express our gratitude to Associate Prof.Mr.G.V.V. Satyanarayana who has been always helping out in design of shear wall, his supervision during the course of our project has been proved as an greatest asset to our project. We would like to express our sincere thanks to Cybercity and Ashoka builders, for providing us an opportunity to complete our main project successfully, which is part of our course curriculum. The training would not have successfully completed without the guidance of Mr. Kiran (Structural Engineer) and Mr. Sudheer (Assistant Project Manager)
GRIET
Page 3
DECLARATION We hereby declare that the work presented in this project titled Design and Construction of Shear walls submitted towards completion of main-project in Seventh Semester of B.Tech (CIVIL ENGINEERING) at the GokarajuRangaraju Institute of Engineering and Technology affiliated to Jawaharlal Nehru Technological University, Hyderabad is authenticate work and had not been submitted to any University or Institute for any award.
K.BHASKER RAO (09241A0163) A.KAMAL TEJ (09241A0169) MD.BASEERUDDIN (09241A0176) B.RAVI TEJA (09241A0191)
GRIET
Page 4
Abstract
Besides, food and clothing, shelter is a basic human need. India has been successful in meeting the food and clothing requirements of its vast population; however the problem of providing shelter of all is defying solutions. While there has been an impressive growth in the total housing stock from 65 million in 1947 to 187.05 million in 2001, a large gap still exists between the demand and supply of housing units. The Working Group on Housing for the 9th five-year plan estimated the housing shortage in 2001 at 19.4 million units- 12.76 million in rural area and 6.64 million in urban area. The shortage of housing is acutely felt in urban areas more so in the 35 Indian cities, which according to the 2001 census have a population of more than a million. Hence in order to overcome this problem construction process should be quick, tall and effective to accommodate huge population in a given area. So we have chosen this topic of DESIGN AND CONSTRUCTION OF SHEAR WALLS. This type of shear wall construction helps to build tall structure of about 20 floors within no time. Hence the construction process will become much quicker and efficient. Constructions made of shear walls are high in strength ,they majorly resist the seismic force, wind forces and even can be build on soils of weak bases by adopting various ground improvement techniques. Not only the quickness in construction process but the strength parameters and effectiveness to bare horizontal loads is very high. Shear walls generally used in high earth quake prone areas, as they are highly efficient in taking the loads. Not only the earth quake loads but also winds loads which are quite high in some zones can be taken by these shear walls efficiently and effectively. Though these types of constructions have their origin in western nations in early 90s, this ideology has changed rapidly and spread all over the world with in no time. The form work used in this type of construction is of a new kind in Indian construction scenario. Certain patented systems based on imported technologies such as Mascon System (Canada), Mivan System (Malaysia) have come on the Indian scene in recent years. In these systems traditional column and beam construction is eliminated and instead walls and slabs are cast in one operation at site by use of specially designed, easy to handle (with minimum labor and without use of any equipment) light weight pre-engineered aluminum forms. Rapid construction of multiple units of a repetitive type can be achieved with a sort of assembly line production by deployment of a few semi-skilled labors.
GRIET
Page 5
DESIGN AND CONSTRUCTION OF SHEAR WALLS The entire operation essentially comprises fitting and erecting the portion of shuttering as already determined (the optimization in use is determined by appropriate planning) and then carrying out concreting of the walls and slabs. Props are so designed that they stay in position while de-shuttering of slabs and/or takes place. The dimensional accuracy of the formwork is of high order. Therefore any possibility of errors does not rise. Though this type of constructions are cost effective, still in order to build a better society and for satisfying present need of shelter , shear wall construction are going to be a solution to this problem of shelter in our nation. The main idea of we taking this topic of Design and construction of shear walls is the challenging task in designing of shear walls. Shear walls have a peculiar behaviour towards various types of loads. Calculation of rigidity factor, reactions, shear center, shear force and bending moment is a topic of interest. Hence by adopting the technologies used in Cyber City, Rainbow Vista, Near IDPL road, Moosapet, to the college building of GRIET fourth block, we are going to check the building behaviour. We are also verifying and designing this same structure using extended three dimensional analysis of buildings (ETABS) software. As said by Benjamin Franklin An investment in knowledge pays the best interest. We would like to invest our knowledge to whatever extent we can and design the building most efficiently
CONTENTS
TITLE
PAGE NO:
CHAPTER 1: Introduction 1.1 Definition 1.2 Scope of the work 1.3 Objective 1.4 Organization
GRIET
Page 6
CHAPTER 2: Literature Review 2.1 Review of Literature CHAPTER 3: Shear Walls 3.1 Purpose of constructing shear wall 3.2 Comparison of shear wall with conventional Load bearing wall 3.3 Forces acting on shear wall 3.4 Classification of shear wall 3.5 Types of shear walls CHAPTER 4: Manual design of shear wall 4.1 Introduction 4.2 Calculation of rigidity values 4.3 Calculation of shear centre 4.4 Calculation of seismic and shear forces at Different floors in collegebuilding 4.5 Design the ductile shear wall for college building CHAPTER 5: Design of college building using E-Tabs 5.1 Marking of columns, beams 5.2 Drawing floor area 5.3 Assigning of loads 5.4 Analysis 5.5 Results CHAPTER 6: Construction of shear walls
GRIET Page 7
6.1 Excavation 6.2 Foundation and Footings 6.3 Bottom three floors and Waffle slab 6.4 Shear wall construction 6.5 Mivan formwork 6.6 Wall ties, Pins and Wedges 6.7 Electrical boards and Plumbing lines 6.8 Concreting 6.9 Curing 6.10 Holes in the slab 6.11 Electrical and Plumbing lines after Concreting 6.12 Painting and Finishing
CHAPTER 8: Conclusion
CHAPTER 9: References
Chapter 1
GRIET
Page 8
INTRODUCTION
1.1 Definition
Shear walls are vertical elements of the horizontal force resisting system. Shear walls are constructed to counter the effects of lateral load acting on a structure. In residential construction, shear walls are straight external walls that typically form a box which provides all of the lateral support for the building. When shear walls are designed and constructed properly, and they will have the strength and stiffness to resist the horizontal forces. In building construction, a rigid vertical diaphragm capable of transferring lateral forces from exterior walls, floors, and roofs to the ground foundation in a direction parallel to their planes. Examples are the reinforced-concrete wall or vertical truss. Lateral forces caused by wind, earthquake, and uneven settlement loads, in addition to the weight of structure and occupants; create powerful twisting (torsion) forces. These forces can literally tear (shear) a building apart. Reinforcing a frame by attaching or placing a rigid wall inside it maintains the shape of the frame and prevents rotation at the joints. Shear walls are especially important in high-rise buildings subjected to lateral wind and seismic forces. In the last two decades, shear walls became an important part of mid and high-rise residential buildings. As part of an earthquake resistant building design, these walls are placed in building plans reducing lateral displacements under earthquake loads. So shear-wall frame structures are obtained. Shear wall buildings are usually regular in plan and in elevation. However, in some buildings, lower floors are used for commercial purposes and the buildings are characterized with larger plan dimensions at those floors. In other cases, there are setbacks at higher floor levels. Shear wall buildings are commonly used for residential purposes and can house from 100 to 500 inhabitants per building
GRIET
Page 9
DESIGN AND CONSTRUCTION OF SHEAR WALLS The scope is to analyze the constructed shear wall that is to be constructed. Firstly the model is implemented into known computer software and then it is analyzed based on the investigation of strength and ductility. The strength of shear walls tested are compared with the calculated strengths based on design codes.
1.3 Objective
Shear walls are not only designed to resist gravity / vertical loads (due to its self-weight and other living / moving loads), but they are also designed for lateral loads of earthquakes / wind. The walls are structurally integrated with roofs / floors (diaphragms) and other lateral walls running across at right angles, thereby giving the three dimensional stability for the building structures.
Shear wall structural systems are more stable. Because, their supporting area (total crosssectional area of all shear walls) with reference to total plans area of building, is comparatively more, unlike in the case of RCC framed structures.Walls have to resist the uplift forces caused by the pull of the wind. Walls have to resist the shear forces that try to push the walls over. Walls have to resist the lateral force of the wind that tries to push the walls in and pull them away from the building. Shear walls are quick in construction, and in a country like India where shelter is very important in a short lapse of time shear walls can be built very quickly.The precision to which they are built is also very high compared to normally built brick structures. Hence the key objective of shear wall is to build a safe, tall, aesthetic building.
1.4 Organisation
The colors of the rainbow light up your life at Rainbow Vistas. For the discerning individual and for those to whom quality of life is something they care about Rainbow Vistas is a 4.3 acres 450 luxury apartments the best option and only solution. This dream housing project is strategically located near HI-TECH City, MMTS and the citys IT hub on one side and prime residential area on the other. A prestige project jointly promoted by Ashoka Developers and Builders Ltd and Cybercity Builders and Developers Pvt. Ltd, Rainbow Vistas adds value to your dream. Rainbow Vistas is approved by GHMC and all leading banks and institutions offer loans for the property. The project has the first Hill-top club house and construction work is at full swing. We are most obliged to have our main project being done in Rainbow Vistas, as a part of our fulfillment of bachelors degree. They have been very patient, co operativethrough out our main project. The information given by them is immense and very useful in completion of our project
GRIET
Page 10
Review of literature:
Development of shear wall system for construction has advanced dramatically over the past few years. Shear wall systems were initially developed to reduce damage due to earth quakes labour requirements, increase strength of the building, shorten construction time reduce cost increase quality of life.
U.H. Varyani described about shear walled buildings under horizontal loads. Considering in his design Reinforced concrete framed buildings are adequate for resisting both the vertical and the horizontal loads acting on shear walls of a building.In his 2nd edition 2002 of Design of structures. He gave rigidity of shear wall, torsional rigidity and shear center of a building in a detailed description.
S.K. Duggal on his profound interest on structures gave a detailed description about reinforced concrete buildings in his book Earth quake resistant design of structures describing a wall in a building which resist lateral loads originating from wind or earthquakes are known as shear walls. He considered flexural strength in the wall to be dominant force based on which design of structure to be carried out in tall shear walls. He described in detail about various types of shear walls with their load bearing capacities as per code requirements.
Mr A.P. Jadhav Associate Professor Rajarambapu Institute of technology rajaramnagar, Islampur has given a detailed report on the form work used for the construction of shear walls. Mr.A.P.Jadhav highlighted the importance of quickness in construction and the need for earthquake resistant building for better sustainability of life.
A report on effects of openings in shear walls on seismic response of structure by sharminrizachowdhary, department of civil engineering dhake-1208, Bangladesh mostly focused
GRIET Page 11
DESIGN AND CONSTRUCTION OF SHEAR WALLS on the design of shear walls with openings on seismic response using E-Tabs,i.e extended three dimensional analysis of buildings. This report gives a detailed explanation of how ETABS can be effectively used to design shear walls.
GRIET
Page 12
Shear walls are vertical elements of the horizontal force resisting system. Shear walls are constructed to counter the effects of lateral load acting on a structure. In residential construction, shear walls are straight external walls that typically form a box which provides all of the lateral support for the building. When shear walls are designed and constructed properly, and they will have the strength and stiffness to resist the horizontal forces. In building construction, a rigid vertical diaphragm capable of transferring lateral forces from exterior walls, floors, and roofs to the ground foundation in a direction parallel to their planes. Examples are the reinforced-concrete wall or vertical truss. Lateral forces caused by wind, earthquake, and uneven settlement loads, in addition to the weight of structure and occupants; create powerful twisting (torsion) forces. These forces can literally tear (shear) a building apart. Reinforcing a frame by attaching or placing a rigid wall inside it maintains the shape of the frame and prevents rotation at the joints. Shear walls are especially important in high-rise buildings subjected to lateral wind and seismic forces. In the last two decades, shear walls became an important part of mid and high-rise residential buildings. As part of an earthquake resistant building design, these walls are placed in building plans reducing lateral displacements under earthquake loads. So shear-wall frame structures are obtained. Shear wall buildings are usually regular in plan and in elevation. However, in some buildings, lower floors are used for commercial purposes and the buildings are characterized with larger plan dimensions at those floors. In other cases, there are setbacks at higher floor levels. Shear wall buildings are commonly used for residential purposes and can house from 100 to 500 inhabitants per building
DESIGN AND CONSTRUCTION OF SHEAR WALLS structures. Shear wall structural systems are more stable. Because, their supporting area (total crosssectional area of all shear walls) with reference to total plans area of building, is comparatively more, unlike in the case of RCC framed structures. Walls have to resist the uplift forces caused by the pull of the wind. Walls have to resist the shear forces that try to push the walls over. Walls have to resist the lateral force of the wind that tries to push the walls in and pull them away from the building. Shear walls are quick in construction, as the method adopted to construct is concreting the members using formwork. Shear walls doesnt need any extra plastering or finishing as the wall itself gives such a high level of precision, that it doesnt require plastering.
3.2 COMPARISONS OF SHEAR WALL WITH CONSTRUCTION OF CONVENTIONAL LOAD BEARING WALLS
Load bearing masonry is very brittle material. Due to different kinds of stresses such as shear, tension, torsion, etc., caused by the earthquakes, the conventional unreinforced brick masonry collapses instantly during the unpredictable and sudden earthquakes. The RCC framed structures are slender, when compared to shear wall concept of box like threedimensional structures. Though it is possible to design the earthquake resistant RCC frame, it requires extraordinary skills at design, detailing and construction levels, which cannot be anticipated in all types of construction projects. On the other hand even moderately designed shear wall structures not only more stable, but also comparatively quite ductile. In safety terms it means that, during very severe earthquakes they will not suddenly collapse causing death of people. They give enough indicative warnings such as widening structural cracks, yielding rods, etc., offering most precious moments for people to run out off structures, before they totally collapse. For structural purposes we consider the exterior walls as the shear-resisting walls. Forces from the ceiling and roof diaphragms make their way to the outside along assumed paths, enter the walls, and exit at the foundation.
GRIET
Page 14
GRIET
Page 15
RC SHEAR WALL:
It consists of reinforced concrete walls and reinforced concrete slabs. Wall thickness varies from 140 mm to 500 mm, depending on the number of stories, building age, and thermal insulation requirements. In general, these walls are continuous throughout the building height; however, some walls are discontinued at the street front or basement level to allow for commercial or parking spaces. Usually the wall layout is symmetrical with respect to at least one axis of symmetry in the plan.
Floor slabs are either cast-in-situ flat slabs or less often, precast hollow-core slabs. Buildings are supported by concrete strip or mat foundations; the latter type is common for buildings with basements. Structural modifications are not very common in this type of construction.
GRIET Page 16
DESIGN AND CONSTRUCTION OF SHEAR WALLS Reinforcement requirements are based on building code requirements specific for each country. In general, the wall reinforcement consists of two layers of distributed reinforcement (horizontal and vertical) throughout the wall length. In addition, vertical reinforcement bars are provided close to the door and window openings, as well as at the wall end zones (also known as boundary elements or barbells).
Plywood shear walls consist of: Plywood, to transfer shear forces Chords, to resist tension/compression generated by the over turning moments Base connections to transfer shear to foundations.
GRIET Page 17
GRIET
Page 18
FIGURE : 3.5.3 PLATE SHEAR WALL Steel plate shear wall systems have been used in recent years in highly seismic areas to resist lateral loads. Figure shows two basic types of steel shear walls; unstiffened and stiffened with or without openings.
DESIGN AND CONSTRUCTION OF SHEAR WALLS buildings. They could be placed symmetrically along one or both directions in plan. Shear walls are more effective when located along exterior perimeter of the building such a layout increases resistance of the building to twisting.
GRIET
Page 20
4.1 INTRODUCTION
The walls, in a building, which resist lateral loads originating from wind or earthquakes, are known as shear walls. A large portion of the lateral load on a building, if not the whole amount, as well as the horizontal shear force resulting from the load, are often assigned to such structural elements made of RCC. These shear walls, may be may be added solely to resist horizontal force, or concrete walls enclosing stairways, elevated shafts, and utility cores may serve as shear walls. Shear walls not only have very large in-plane stiffness and therefore resist lateral load and control deflection very efficiently, but may also help to ensure development of all available plastic hinge locations throughout the structure prior to failure. The other way to resist such loads may be to have the rigid frame augmented by the combination of masonry walls. The use of shear walls or their equivalent becomes imperative in certain high-rise buildings, if inter- storey deflections caused by lateral loadings are to be controlled. Well-designed shear walls not only provide adequate safety, but also give a great measure of protection against costly non-structural damage during moderate seismic disturbances. The term shear wall is actually a misnomer as far as high-rise buildings are concerned, since a slender shear wall when subjected to lateral force has predominantly moment deflections and only very insignificant shear distortions. High-rise structures have become taller and more slender, and with this trend the analysis of shear walls may emerge as a critical design element. More often than not, shear walls are pierced by numerous openings. Such shear walls are called coupled shear walls. The walls on both sides of the openings are interconnected by short, open deep, beams forming part of the wall, or floor slab, or both of these. The structural engineer is fortunate if these walls are arranged in a systematic pattern. The scope of the book limits the discussion to shear walls without any openings. This shows a building with the lateral force represented by arrows acting on the edge of each floor or roof. The horizontal surfaces act as deep beams to transmit loads to vertical-resisting elements-the shear walls A and B. These walls, in turn, act as cantilever beams fixed at their base and transfer loads to the foundation. For the building plan additional shear walls C and D are provided to resist the lateral loads that may act in the orthogonal direction. The shear walls are subjected to the following loads: (a) A variable shear which reaches a maximum at the base. (b) A bending moment which tends to cause vertical tension near the loaded edge and compression at the far edge. (c) A vertical compression due to ordinary gravity loading from the structure.
GRIET Page 21
is defined as the horizontal force necessary to prevent y-distortion of a wall element when Rx is applied in the x-direction producing a unit deflection. is also similarly defined. This gives the directions of and for various positions of the angle section. When the principal axes of the shape of a shear wall are parallel to the X and Y axes, and vanish. Table 8.1 gives the values of and calculated as explained by Benjamin.
Rigidity of a Wall Element Normal to the Direction of Horizontal Shear to Ensure Simple Bending ( , ):
Where 0 equals the perimeter of the section of shear wall of height h and thickness t. It, however, works out to be negligibly small in the case of open sections such as channels, angles, tees, etc. Being a function of the cube of thickness of shear wall, which is assumed to be very small in comparison to its other dimensions. However, for box sections, it is not a small quantity, as it is proportional to its thickness. The non-uniform torsion theory applied to flanged walls of open cross-sections and gives approximate torsion rigidity based on the rigidities of separated flanges opposite to each other, neglecting the web. Referring to for an I-section, rotation in radians due to a unit displacement of either flange on account of force is given by = ,
Where = rigidity of the flange, i.e. a wall element of length b and thickness t. The torsional rigidity is, by definition, given on th basis of non-uniform torsion theory as, = = x
For box sections, the torsion due to non-uniform theory can be neglected. The torsional rigidity of a shear wall is then given by, J= + This gives the values of torsional rigidities of various shapes of shear walls.
Where (x, y) give the location of the shear centre of the structure and the point chosen O1 is the origin of axes x1and y1 and the summation extends to all the shear walls joined monolithically with the floor diaphragm. The equations are solved for x and y to locate the shear centre of the structure, taking proper signs of all the forces involved.
GRIET Page 23
DESIGN AND CONSTRUCTION OF SHEAR WALLS In the case, when = = 0 for all the existing shear walls, Eqs. (8.11) and (8.12) simplify to X= Y= Case Shape of lx shear wall
ly
Ay
Ax
Rx
Ry
J R o r
1 2
+ 6 12
1 12
2 + 3 + 2
1 t 12
Lt
Lt
Cx=Cy=0
m=0
Step 1: Evaluation of rigidity characteristics of shear walls. As all the shear walls forming the structure are of same material, E is being omitted from all expressions of rigidity characteristics.
GRIET Page 24
= x L x
= x x t
= 0.056
= x 25 x 0.3
= x 25 x 0.3 = 390.62
. . . .
Rigidity = 0.683 = 0 = = 0
Torsional rigidity J= 0 Position of centroid = = 0 Shear center m = 0 Shear wall " B " resembles " A"
GRIET Page 25
= 10 x 0.3 =3m = 3 m
= 25
x 0.3 x 10 x 10 x 0.3
= =
= 0
= 0.0225
. .
= 0.22 Torsional rigidity J=0 Position of centroid ( , ) = 0 Shear centre (m) = 0 Shear wall D resembles same as C Summary of rigidity characteristics Shear wall A B C D Summation () 0.683 0.683 0 0 1.366 0 0 0.22 0.22 0.44 0 0 0 0 0 0 0 0 m 0 0 0 0 J 0 0 0 0
GRIET
Page 26
Step 2: Location of shear centre of the structure: Assuming the quantities required for location
Shear wall A B C D
0 40 0 -15 -
0 27032 0 0 27.32
0 0 0 0 -
0 41 15 40 -
0 40 0 -15 0
0 0 0 0 0
axes ( ) to be coincident with the shear center of the shear wall (A), the shear center of structure ( , ), the various quantities required in the above equations being computed with the help of above table x 1.366 - ( 0) = 27.32
= 20
Therefore the value of the shear center is (27.5,20) for the college shear wall of fourth block south east wall of G.R.I.E.T.
GRIET
Page 27
GRIET
Page 28
DESIGN AND CONSTRUCTION OF SHEAR WALLS the flexural stresses and the web carries the entire shear. In shear walls of high-rise structures, enough shear capacity is provided so that a shear failure does not precede a flexural failure. However, a portion of a shear wall, which interacts with the frames, may behave as a low shear wall, depending upon the proportions of the walls and the location of the point of contra flexure along the height of the wall. The latter is dependent primarily on the relative stiffness of the frame and the shear wall elements in a structure.
FLEXURAL STRENGTH:
In shear walls, particularly in areas not affected by earth quakes, the strength requirement for flexural steel is not great. Traditionally, the practice is to provide about 0.25 per cent reinforcement uniformly in both directions over the entire depth. Naturally, such an arrangement does not efficiently utilize the steel at the ultimate moment because many bars operate on a relatively small lever arm. Moreover, the ultimate curvature, hence the curvature ductility, is considerably reduced and this arrangement is also uneconomical. In an efficient shear wall section subjected to considerable moments, the bulk of the flexural reinforcement is placed close to the tensile edge. Because of moment reversals originating from lateral loads, equal amounts of reinforcement are normally required at both extremities. Thus, a considerable part of bending moment can be resisted by the internal steel couple, and this will result in improved ductility properties. The practice is to provide minimum reinforcement over the inner 80 percent depth and allocate the remainder of the steel to outer zones of the section. As shown by the theoretical moment-curvature relationship, this distribution of steel results in an increase in the available strength and ductility. To increase the ductility of cantilever shear walls at the base, where the overturning moments and axial compression are the largest, the concrete in the compression zone must be confined. The confining steel is provided in the same way as in tied columns and can be extended over the part of the depth , where concrete strains in excess of 0.0035 are required. This is particularly important over the region of a possible plastic hinge, which may extend over a full storey height or more. The flexural strength of a slender rectangular shear wall section with uniformly distributed vertical reinforcement and subjected to uniaxial bending and axial load may be estimated as follows:
GRIET
Page 29
0.168 + = 1 + 0.416
Where
= =
. . .
.
,=
= .
Where is the depth of the neutral axis from extreme compression flange,is the balanced depth of neutral axis, is the inclination of the diagonal reinforcement in the coupling beam, is the soil-foundation factor (IS 1893: 2002), is the vertical reinforcement ratio, is the area of uniformly distributed vertical reinforcement,
1.0
= - - -
GRIET
Page 30
and
The values of to be used in this equation, can be calculated from the following quadratic equation
+ + = 0
= and =
From the above equations we have derived assuming a rectangular wall section of depth and thickness that is subjected to combined uniaxial bending and axial compression. The vertical reinforcement is represented by an equivalent steel plate along the length of the section. The stress-strain curve assumed for concrete is as per IS 456:2000, whereas that for steel is assumed to be bilinear. Above equations are given for calculating the flexural strength of the section. Their use depends on whether the section fails in flexural tension or in flexural compression.
SHEAR STRENGTH
The shear strength of tall shear walls can be assessed in the same way as for beams, with due allowance made for the contribution of axial compression in boosting the share of the concrete shear-resisting mechanism. In doing so, the adverse effect of vertical acceleration induced by earthquakes should also be considered. At the base of the wall, where yielding of the flexural steel is possible in both faces, the contribution of the concrete towards the shear strength should be neglected and shear reinforcement in the form of horizontal stirrups should be provided at least over the possible length of the plastic hinge, to carry all the shear force. The minimum reinforcement of 0.25 per cent in the horizontal direction, when appropriately anchored, is found to be sufficient. The effective depth of the rectangular shear wall can be taken as greater than 0.8 . It must be noted that flanges of the shear wall are not taken into account while calculating the shear strength.
GRIET
Page 31
DESIGN AND CONSTRUCTION OF SHEAR WALLS In the potential plastic hinge zone, wide flexural cracks combine with diagonal tension cracks, due to shear. The effect of diagonal cracking on the distribution of flexural shear stresses should be considered in the same way as in beams.
CONSTRUCTION JOINTS
There are two potential locations in cantilever shear walls where failure by sliding shear can occur. One is a horizontal construction joint and the other is the plastic hinge zone, usually immediately above the foundation level. The inelastic response of mechanisms associated with sliding shear indicates drastic loss of stiffness and strength with reversed cyclic loading. Therefore, sliding shear should be considered as being an unsuitable energy dissipating mechanism in earthquake resistant structures. Earthquake damage in shear walls is more common at construction joints along which sliding movement may occur necessitating efficient vertical reinforcement to check sliding. The shear force that can be safely transferred across a well prepared rough horizontal joint is given by + 0.87 )
and is the coefficient of the friction at the joint ( = 1.0). For shear walls, the gravity loads with 20 percent reduction to account for negative vertical acceleration are considered = 0.8Pu +0.87 The strength of the construction joint is =
And this must be equal to but preferably greater than the diagonal tension shear strength of the wall. The steel content across the construction joint is given by
GRIET
Page 32
The vertical reinforcement ratio, across a horizontal construction joint should not be less than
0.0025
Where is the factored shear stress at the joint, is the factored axial force, and is the gross cross-sectional area of the joint.
GENERAL REQUIREMENTS
(a) The thickness of the shear wall should not be less than 150mm to avoid unusually thin sections. Very thin sections are susceptible to lateral instability in zones where inelastic cyclic loading may have to be sustained. (b) The effective flange width for the flanged wall section from the face of web should be taken as least of Half the distance to an adjacent shear wall web, and One-tenth of total wall height. (c) The minimum reinforcement in the longitudinal and transverse directions in the plan of the wall should be taken as 0.0025 times the gross area in each direction and distributed uniformly across the cross-section of wall. This helps in controlling the width of inclined cracks that are caused due to shear.
GRIET Page 33
DESIGN AND CONSTRUCTION OF SHEAR WALLS (d) If the factored shear stress in the wall exceeds 0.25fck or if the wall thickness exceeds 200 mm, the reinforcement should be provide in two curtains, each having bars running in both the longitudinal and transverse directions in the plane of the wall. The use of reinforcement in two curtains reduces fragmentation and premature deterioration of the concrete under cyclic loading.
(e) The maximum spacing of reinforcement in either direction should be lesser than , 3 , and
450mm, where is the horizontal length and is the thickness of the wall web.
(f) The diameter of the bars should not exceed one-tenth of the thickness of that part. This puts a check on the use of very large diameter bars in thin wall sections.
SHEAR STRENGTH
The provisions for shear strength are almost same as those of RCC beams. The increase in shear strength may also be considered. However, for this, only 80 percent of the factored axial force is considered as effective. This reduction of 20 per cent is made to account for possible effect of vertical acceleration. (a) The nominal shear stress is =
Where is the factored shear force, is the thickness of web, and is the effective depth of the wall section. (b) The design shear strength of concrete ( ) should be as per IS 456: 2000.
(c) The nominal shear stress, , should not be greater than . The value of can be found from IS 456: 2000. If < , minimum shear reinforcement of 0.25 percent should be provided in the horizontal direction. If > , the area of horizontal shear reinforcement, , at a vertical spacing, , can be determined from the expression =
.
Where is the shear force to be resisted by the horizontal reinforcement and is given by =
(d) Uniformly distributed vertical reinforcement not less than the horizontal reinforcement should be provided. This is particularly important for squat walls. When the height-to-width ratio
GRIET
Page 34
DESIGN AND CONSTRUCTION OF SHEAR WALLS is about 1.0, both the vertical and horizontal reinforcement are equally effective in resisting the shear force.
FLEXURAL STRENGTH
The moment of resistance of short shear walls is calculated as for columns subjected to combined bending and axial load. The procedure for the calculation of moment of resistance, of tall rectangular shear walls is as described For walls without boundary elements, the vertical reinforcement is concentrated at the ends of the walls. A minimum of four bars, 12mm , arranged in two layers, are provided at each end.
BOUNDARY CONDITIONS
There are the portions along the wall edges and may have the same or greater thickness than the wall web. These are provided throughout the height with special confining reinforcement. Wall sections having stiff and well confined boundary elements develop substantial flexural strength, are less susceptible to lateral buckling and have better shear strength and ductility in comparison to plane rectangular walls not having stiff and well-confined boundary elements. (a) During a severe earthquake, the ends of a wall are subjected to high compressive and tensile stresses. Hence, the concrete needs to be well confined so as to sustain the load reversals without a large deterioration in strength. Thus, the boundary elements are provided along the vertical boundaries of walls, when the extreme fibre compressive stress in the wall due to factored gravity load plus factor earthquake force exceeds 0.2fck. The boundary element may be discontinued where the calculated compressive stress becomes less than 0.15fck. (b) The boundary element is assumed to be effective in resisting the design moment due to earthquake induced forces, along with the web of the wall. The boundary element should have an adequate axial load carrying capacity so as to carry an axial compression equal to the sum of the factored gravity load plus compressive load due to seismic load. The latter may be calculated as =
Where Mu is the factored design moment on the entire wall section, is the moment of resistance provided by the distributed reinforcement across the wall section, and is the c/c distance between the boundary elements along the two vertical edges of the wall. (c) Moderate axial compression results in higher moment capacity of the wall. Hence, the beneficial effect of axial compression by gravity loads should not be fully relied upon in a
GRIET Page 35
DESIGN AND CONSTRUCTION OF SHEAR WALLS design, due to the possible reduction in its magnitude by vertical acceleration. When gravity loads add to the strength of the wall, a load factor of 0.8 may be taken (d) The percentage of vertical reinforcement in boundary elements should range between 0.8 and 6 percent. (e) During a severe earthquake, boundary elements may be subjected to stress reversals. Hence, they have to be confined adequately to sustain the cyclic loading without a large degradation in strength. Therefore, these should be provided throughout their height. (f) Boundary elements need not be provided if the entire wall section is provided with special confining reinforcement.
To calculate: The seismic forces and shears at different floor levels. Design the ductile shear wall to resist seismic forces. Solution:
GRIET Page 36
DESIGN AND CONSTRUCTION OF SHEAR WALLS Seismic weight of the building: As per IS code 1893:2002 the percentage of design live load to be considered for the calculation of earthquake. Force is 25% for the floors and no live load needs to be considered for roof. Hence the effective weight of each floor = 4.0 + 2.0 + 0.25 x 4 = 7 KN/ .
Self weight of 80 columns = 0.3 x 0.6 x 4 x 25 x 80 = 1440 KN Weight of columns at roof = 1440 = 720
Weight of 140 beams = 0.45 x 0.300 x 5 x 140 x 25 = 2362.5 Plan area of building = (40 x 40.5) + (10 x 20) = 1820 Equivalent load at roof level = 4 x 1820 + 2362.5 + 720 = 10363.5 KN Equivalent load at each floor = 6.75 x 1820 + 2362.5 + 1440 = 16087.5 KN Seismic weight of building = 10363.5 + (16087.5 x 4) = 74713.5 KN
Base shear: The fundamental natural period of vibration (T) for the buildings having shear walls is T=
.
= 0.28
Building is situated in Hyderabad zone II. As per zone factor (Z) = 0.10 Importance factor (I) = 1.5 Response reduction Ductile shear wall with shear moment resistant frame (R) = 5 For 5% damping and type I soil
= 1.81
GRIET
Page 37
. . .
= 0.02715
Base shear = x W = 0.02715 x 74713.5 = 2028.47 Design lateral force at various floor levels. Design lateral force at floor i: =
20 16 12 8 4
Bending moment and shear force: Two shear walls are provided as given in the problem to resist the seismic forces in each direction The shear wall is assumed to be cantilever in calculations. Maximum shear force at base (V) = 1013.82 KN Maximum bending moment at base M = (21.4 x 4) + (87.95 x 8) (197.75 x 12) + (3510.95 x 16) (354.27 x 20) = 15878.8 KN. m Taking partial safety factor = 1.5 Factored shear force ( ) = 1.5 X 1013.82 = 1520.73
Factored bending moment ( ) = 15878.8 x 1.5 = 23818.2 Considering axial load acting = 16000 KN Factored axial load = 1.5 x 16000 = 24000 KN Flexural strength of shear wall: = 30 N / m
= 2.0 x 10 N/ m
GRIET Page 38
= 415 N / m
Thickness of wall ( ) = 0.3 m Providing uniformly distributed vertical reinforcement ratio = 0.25% =
. . .
= =
= 0.030
= = 0.0728 = 0.109
= . = . = 0.5158
= . = . . = 0.3309 =
. .
..
= 0.6597
<
= 30 x 300 x 24400 x 0.03 1 + = 1.607 x10 0.53 0.111 = 2.638694 x10 = 67513.8 KN m = 263869.4 Factored bending moment = 23818.2
DESIGN AND CONSTRUCTION OF SHEAR WALLS Balance moment to be resisted by the edge reinforcement in each shear wall = 23818.2 + 67513.8 = 43695.6 Effective depth of wall = 0.9 = 0.9 x 24400 = 21960 Area of steel = .
= 5511.09
Equal amount of reinforcement is provided on the vertical edges of the wall which will act like the flanges of a steel beam. Provide 20 numbers. 20 bars in two layers in the wall at each end. Provided at ends = 314.15 x 20 = 6283 m 0.8 = 19520 mm. Minimum area of steel required in the shear wall = 0.0025 x 24400 x 300 = 18300 m Area of minimum reinforcement per meter length of wall = 0.0025 x 1000 x 300 = 750 m Maximum permissible spacing =
or 3 or 450.
= 7880
3 = 3 x 300 = 900 Therefore spacing between reinforcement = 450 mm c/c. Provide 10mm bars at 300 mm c/c in the vertical direction in two layers. Check for shear: Factored shear force ( ) = 1520.73 KN Nominal shear stress =
= = 0.23 N/m
Permissible shear stress for M30 grade concrete and steel ratio,
GRIET Page 40
(As per clause 9.24 of IS: 13920 : 1993 ) If Then As per clause 9.15: If the factored shear stress in the wall exceeds 0.25 or if the wall thickness exceeds 200 mm then the reinforcement is provided in two directions. each having running in horizontal and transverse directions.
, 3 and 450 mm = 450 mm The maximum spacing shall not be smaller than
But area of minimum reinforcement is 750 m . Hence provide minimum reinforcement of 0.25% of the gross area of the wall, in the horizontal direction. Provide 10 bars at 450 mm c/c The detailing of shear wall
= 349.06 m
GRIET
Page 41
GRIET
Page 42
GRIET
Page 43
Firstly click on the ETABS icon .A window appears which shows a different tip every time you open the software. This window provides us 3 options. You can click on previous or next tip to checkout some more tips or else click ok to move further. Change the units at the right bottom to KN-m or any other as per your convenience. Click on file option to create a new file or to open an already existing file When you open a new file another window appears which again contain 3 options - choose. edb - default. edb and -no
-First option helps us to select an already existing file -Second helps us to create a new file and -The third displays the grid data and story data *As we are creating a new file, we click on default.edb
GRIET
Page 44
DESIGN AND CONSTRUCTION OF SHEAR WALLS *A new window appears which has Building plan grid system and Story data. In grid dimensions we can either use uniform spacing or we can customize the grid spacing. We have to provide no of lines in x and y directions as per the columns and beams used in the plan.
*In the story dimensions, we have simple story data and custom story data. In simple story data, use the defaults or specify values for the number of stories, typical story height, and bottom story height. The value specified for the typical story height will be used for all stories in the model, except the bottom story whereas in custom story data we can manually define story names, story levels of non-uniform height, and story similarity. *After providing the entire data click on grid only in structural objects and then click on ok.
GRIET
Page 45
DESIGN AND CONSTRUCTION OF SHEAR WALLS *The next step is to create beams and columns. To create a beam or column, first we click on define=>frame sections command to create a beam or column. In this window we have import and add options further provided with modify or delete options of already existing properties.
GRIET
Page 47
GRIET
Page 48
*To assign a column, we can click on create columns in region or at clicks or click on Draw menu=>Draw line objects=>Create columns in region or at clicks. In this the property is changed to the defined column and columns can be assigned to offsets in x and y directions. Columns are also assigned in the similar way as beams are assigned.
GRIET
Page 50
DESIGN AND CONSTRUCTION OF SHEAR WALLS a click on SetBuilding view options on the top and the option object fill is marked in special effects options.
GRIET
Page 51
GRIET
Page 52
5.3:Assigning of loads:
*After the columns, beams, walls and slabs are assigned now the loads are to be applied to the structure. There are different load combinations used in this software. For shear walls, lateral loads and seismic loads play a vital role. *To assign any particular load, click Define=>Static load cases. In this window dead load and live load are already assigned. To assign any other loads change the name of the load in load option, select the load type in type option, add the self weight multiplier as required. The auto lateral load options provide different code books that are used across the world. We use IS 1893 2002 code.
GRIET
Page 54
*After we have defined the loads that are required to be provided for the structure, now the loads are need to be assigned. For the loads that are acting on beams, select all the beams and then click assign=>frame/line loads =>distributed=>select the load that is to be to assigned and then click ok.
GRIET
Page 55
*For slabs and walls, select all the walls and slabs and then click on assign=>shell/area loads=>uniform. Select the load that is to be assigned and then click ok.
GRIET
Page 56
*To check whether the loads are assigned or not, click display=>show loads=>select joint/point or frame/line or shell/area=>select the load that you need to check in load case and then click ok. The load is displayed in the plan view at the centre. *There are several load combinations that can also be designed depending on the requirements by selecting define=>load combinations and then we can add numerous combinations as per the given code.
GRIET
Page 57
DESIGN AND CONSTRUCTION OF SHEAR WALLS *The additional loads that are to be defined are seismic and lateral loads for shear wall design. Hence quake and wind loads are defined in both x and y directions and then they are assigned to the structure.
GRIET
Page 58
*After all the loads are assigned, now click analyze=>run analysis. After the complete structure is analyzed, the deformed shape of the structure is shown in 3D view. This is due to the loads that are acting on all the sections i.e., beams, columns, walls and slabs.
GRIET
Page 59
GRIET
Page 60
6.1:
Excavation:
After the initial surveying and soil test, excavation of land is carried out. If the land site is very hard with rocks and boulders, excavation is carried out using heavy earthquakes, cranes and diggers. And in some cases if the land is very hard, blasting of site by using small amount of dynamites is preferred. Generally blasting of site is done during early mornings.
Once the excavation is completely done the excavated material is not wasted. It should be generally reused in the same construction work so that construction work is reduced. On the other side, if the land is very loose and site is being excavated very easily then earth movers of normal size are used.
GRIET
Page 61
Fig 6.1.2-DRILLING
Once the excavation is completed marking of land for footings is carried out.
GRIET
Page 62
These footings are tied together by using tie beams so that the moment during lateral load is completely arrested. In accordance with footing neck columns are raised these neck columns once reached to the ground surface are tied together with plinth beam.
GRIET
Page 63
GRIET
Page 64
DESIGN AND CONSTRUCTION OF SHEAR WALLS Now if the building requires parking, the bottom two to three floors are built with heavy beams and columns of dimensions (0.9 x 0.3) m and (0.45 x 0.3) m.
Waffle slab:
The slab here should be of high load bearing as it needs to bare the vehicles load as well as the top floor loads. Hence for this situation waffle slab is most preferred.
Waffle slab is a kind of slab which is of thickness 40 45 cm. But mostly empty with spacing as of waffles. The placing of the waffles is quite peculiar. A form is placed and on above the waffles are arranged, once the arrangement is done, reinforcement is arranged in such a way that it forms a chess board and the squares are hollow and the area with lines act as beams.
GRIET
Page 65
The waffle slab after curing looks like a normal slab from top but from the lower or bottom side it chess board with hollow spacings.
GRIET
Page 66
GRIET
Page 67
DESIGN AND CONSTRUCTION OF SHEAR WALLS After the horizontal reinforcement is placed in accordance with the design, vertical reinforcement is placed.
As per the design details the reinforcement of size 10mm spacing 30mm is placed in the middle of the wall of length 0.8 = 0.8 x 25 = 200 m and the edge reinforcement of 20 mm 20 bars are placed in the remaining 0.2 space. The horizontal bars on the vertical reinforcement are placed of diameter 10 mm spacing 300 mm distance.
GRIET
Page 68
This reinforcement in the horizontal direction is usually tied as double strand single tie with GI wire, this process can also be done by using rebar machine. Normally cover either cement or most preferably PVC cover is tied to the vertical reinforcement so that once form work is place it maintains a specific cover distance. Once the reinforcement is completely placed then comes the part of Mivan form work.
GRIET
Page 69
DESIGN AND CONSTRUCTION OF SHEAR WALLS Mivan is an aluminium formwork system developed by a European construction company. In 1990, the Mivan Company Ltd. from Malaysia started manufacturing these formwork systems. Today, more than 30,000sqm of formwork from Mivan Co. Ltd. is used across the world. There are a number of buildings in Mumbai that are being constructed with the help of the Mivan system, that has proven economical as well as satisfactory for the overall Indian construction environment. One of the architectural examples is XRBIA which uses MIVAN system to achieve its dream of A House for Every Indian
MIVAN technology is suitable for constructing large number of houses in a short span of time using room size forms to construct walls and slabs in one continuous pour on concrete. In this system of formwork construction, castinsitu concrete wall and floor slabs cast monolithic provides the structural system in one continuous pour. To facilitate fast construction, early removal of forms can be achieved by hot air curing / curing compounds. Large room sized forms for walls and floor slabs are erected at site. These strong and sturdy forms are fabricated with
GRIET
Page 70
DESIGN AND CONSTRUCTION OF SHEAR WALLS accuracy and are easy to handle. The concrete is produced in RMC batching plants under strict quality control and convey it to site with transit mixers. The frames for windows, doors and ducts for services are placed in the form before concreting. Staircase flights, panels, chajjas and jails etc. and other pre-fabricated items are also integrated into the structure. This proves to be a major advantage as compared to other modern construction techniques. High quality Mivan Formwork panels ensure consistency of dimensions. On the removal of the formwork mould a high quality concrete finish is produced to accurate tolerances and verticality. The high tolerance of the finish means that, no further plastering is required.
GRIET
Page 71
Uses of Mivan Formwork: 3S System of Construction Speed, Strength, Safety Column and beam construction are eliminated Walls and slabs are cast in one operation Specially designed, easy to handle light weight pre-engineered aluminium forms Fitting and erecting the portion of shuttering Carrying out concreting of the walls and slabs together Advantages: Mivan formwork requires relatively less labour More seismic resistance Increased durability Lesser number of joints and reduced leakages Smooth finishing of wall and slab Uniform quality of construction Negligible maintenance Faster completion Limitations: Even though there are so many advantages of Mivan formwork the limitations cannot be ignored. However the limitations do not pose any serious problems. They are as follows: Because of few small sizes finishing lines are seen on the concrete surfaces Services after completing become slightly difficult due to the small width of components It requires uniform planning as well as uniform elevations to be cost effective The formwork requires number of spacer, wall ties etc. These produce problems such as seepage, leakages during monsoon Due to box-type construction, contraction cracks are likely to appear Heat of hydration is high due to shear walls It is rigid in design once placed, as any alteration becomes tough later Remedial Measures: It is possible to minimize contraction cracks by providing control strips in the structure which could be concreted with a delay of about 3-7 days after major concreting. The problem of cracking can be avoided by minimizing the heat of hydration. Once the mivan panels are placed carefully they are tied generally by using wall ties pins and wedges.
GRIET
Page 73
GRIET
Page 74
Wedge is of thin iron sheet mostly resembles the front view of frustum of cone. Its top size is 2 cm and base is of 1 cm. Once the form is completely placed with wall ties coinciding the holes, pin is placed and wedges are drilled with the help of a wooden hammer. Wall ties with grease and yellow cover finds its importance after concreting. This eases the work of removal of wall ties. Once the concreting is done and cured wall ties are carefully removed by pulling them out. The cover which is placed on the central portion of the wall tie remains inside the wall and the gap which remains is filled with cement mortar.
GRIET
Page 75
GRIET
Page 76
6.8: Concreting:
Once the complete arrangement of the form work i.e., wall ties, pins and wedges with electrical lines are placed completely up to an accuracy of 1 mm, precision is done so that no concrete will leak out of the form work. The cement generally used in this is of grade of concrete is. The size of aggregate should be 10mm or 12mm. So that it moves easily inside the wall. Sand here used may be either robust sand or sea sand. Admixtures generally used are of self compacting nature. Reobuild and Gilinium are two admixtures which are used most effectively in the shear walls construction. These admixtures are generally mixed using a design mix in a transit mixer. Once the mixing is done accurately for specified time, this mixture of concrete is pumped using pipes. Once the form is arranged accurately concrete pouring is done using the hydraulic pumps. As the concrete used in this type is of self compacting nature, there is no need for additional compaction, but still pin vibrators are generally used to place in the wall and vibrate the concrete. After the wall form is completely filled with concrete with proper compaction it is left for one complete day to set in its position.
6.9: Curing:
After one day of curing of the wall, removal of form is done. Removal of form is done very carefully.
GRIET
Page 77
GRIET
Page 78
DESIGN AND CONSTRUCTION OF SHEAR WALLS As it becomes difficult to take form work through staircase for constructing the next floor, these holes are drilled in the slab of size a little more than the standard form work.
Hence these holes play a key hole in transfer of mivan form work.
GRIET
Page 79
When it comes to the server lines holes or empty gaps are left over. And in these empty spaces the sewer pipes are placed exactly to match the empty spaces.
GRIET
Page 80
GRIET
Page 81
Shear walls are considered to be a gift to the future construction industry. Scope of shear walls in construction field is immense. Its since their arrival in market there topic was always a topic of interest. Shear walls are the structures usually build to balance lateral loads acting on the structure. Where the lateral loads are most predominantly wind and earth quake loads. And predominantly earthquake loads are more intense in their effect on the building structures. Earthquakes are becoming more intense due to the key reason that is ground water depleashement . Hence in order to overcome the diverse effects of earthquake its always best to save ourselves from future disasters. Shear walls are quick in construction, as the walls doesnt need any special brick arrangement or plastering they are very quick in their construction. It just requires an effective form work and very few skilled labour. It was estimated that a 20 floors building can be built within six months which is most astonishing. Not only for the quickness in its work and resistance to earthquakes, shear walls are also build for defense purpose. Presently The Hindustan Prefab Limited (HPL) is executing various relocatable prefab structures for paramilitary forces especially for the CRPF in Karnataka, Uttar Pradesh, Chhattisgarh and Bihar among others. We are using Shear Wall technology with thermal curing a fast track technology for KMDA for construction of houses in Kolkata, chairman and managing director HPL JaiveerSrivastava said. In structural engineering, a shear wall is a wall composed of braced panels to counter the effects of lateral load like wind and seismic acting on a structure. Under several building codes including the International Building Code and Uniform Building Code all exterior wall lines in wood or steel frame construction are braced. Plywood is the conventional material used in the construction of shear walls, but with advances in technology and modern building methods, there are other prefabricated options which have made it possible to inject shear assemblies into narrow walls that fall at either side of an opening in a shear wall. Sheet steel and steel-backed shear panels in the place of structural plywood in shear walls have proved to be far stronger in seismic resistance.
GRIET
Page 82
GRIET
Page 83
DESIGN AND CONSTRUCTION OF SHEAR WALLS 7. Steel plate shear wall systems that can be constructed with shop welded-field bolted elements can make the steel plate shear walls more efficient than the traditional systems. These systems can also be very practical and efficient for cold regions where concrete construction may not be economical under very low temperatures.
DESIGN AND CONSTRUCTION OF SHEAR WALLS forward and therefore easily implemented at site. Shear walls are efficient, both interims of construction cost and effectiveness in minimizing earthquake damage in structural and nonstructural elements like glass windows and building contents.
CONCLUSION
Thus shear walls are one of the most effective building elements in resisting lateral forces during earthquake. By constructing shear walls damages due to effect of lateral forces due to earthquake and high winds can be minimized. Shear walls construction will provide larger stiffness to the buildings there by reducing the damage to structure and its contents. Not only its strength , in order to accommodate huge number of population in a small area tall structures with shear walls are considered to be most useful. Hence for a developing nation like India shear wall construction is considered to be a back bone for construction industry.
GRIET
Page 85
References
U.H. Varnayi in his second edition of Design of structures S.K. Duggal in his Earth quake resistant design of structures Page no:301 ,8.12 about Shear walls. S.K. Duggal in his Earth quake resistant design of structures pg.no:305 on flexural strength 8.14.1 case:1, case:2. S.K. Duggal in his Earth quake resistant design of structures 8.16 Design of Shear walls which is also given in Is code 13920:1993 Mr A.P. Jadhav Associate Professor Rajarambapu Institute of technology rajaramnagar, Islampur has given a detailed report on the form work used for the construction of shear walls. A report on effects of openings in shear walls on seismic response of structure by sharminrizachowdhary, department of civil engineering dhake-1208, Bangladesh mostly focused on the design of shear walls with openings on seismic response using E- Tabs I.S 456:2000 As per clause 32, design for wall describes, design of horizontal shear in clause 32.4 given details of how shear wall have to be constructed. I.S:1893 Criteria of Earth Quake resistant Buildings Part (3) page 23, clause 4.2 gives the estimation of earth quake loads. In IS: 13920:1993 it gives the ductile detailing of shear wall as per clause 9, where 9.1 gives general requirements. 9.2 shear strength 9.3 gives flexural strength 9.6 gives openings in shear walls. Ductile detailing, as per the code IS: 13920:1993 is considered very important as the ductile detailing gives the amount of reinforcement required and the alignment of bars
GRIET
Page 86