We design, manufacture and sell food products compact and reliable to be used while in motion to provide auxiliary or emergency power. Our mobile product line includes investors who are well combined with a built-in battery power, or are designed to work with an external power source, such as a car battery or generator. These products and systems that have a user interface intelligent design are installed in boats, recreational vehicles, utility and emergency vehicles, heavy trucks and cars. They are also used as independent portable power systems. Energy core products offer customers the freedom and safety of cleanliness, quiet electricity when and where they need it.
- Several versions based on the number of available input stages. Each input stage allows up to 30A (12 and 24V) or up to 20A (at 48V). Standard versions allow up to four input stages. On request can be made up with eleven stages. - Control system by deep load waterline, allowing periodic equalizing charges automatically and manually. - Line voltage control independent battery power line, which prevents measurement errors due to high voltage currents that can run on the battery line. - Disconnection consumption by low battery voltage, with automatic reset. - Compensation of load thresholds and the temperature measured with a built- in probe. - Reading LCD alphanumeric display (4 rows x 16 characters) of the following parameters : system voltage , total and partial intensity generation stage , intensity of consumption generated by stage Ah , consumed and accumulated , generated , consumed and accumulated Total , probe temperature , load balancing , date and time , etc. . - Indication of the charging state and local alarm high and low battery voltage via LEDs and display. - Alarms by potential free relay: high and low battery voltage, fault generation panels, system crash and boot generator. - Two auxiliary inputs of 0 to 5V (measure of radiation, ambient temperature or similar purposes). Chance (optional) to associate alarms to these inputs. - Detection day / night beacon activation. - Tables preset voltages in software customization option values using password batteries. - Waterproof box with transparent front - Protection breakers lines input panel, battery and load. - Surge protection on power inputs and line control. - Self-protection against over current and over temperature. - Protection against battery disconnects. - Protection against polarity inversion lines of control and power. - Protection against short circuit and disconnect the temperature probe. - Four languages in the information display: Spanish, English, French and German. - Polarized planes between the power stages and control gold plated (flax level).
- Tropicalization circuit wiring and interior color identification and numbering. - Digital communication line for data transmission via RS232, in the standard model. This line provides information of Modem and even modifies system operating parameters. - Reporting by ISPRA RS- 232 line, with configurable interval.
Before disconnecting the battery of 12 V. assistant, as any conventional vehicle, to: Use the energy security controls. Open windows to ventilate any harmful gas due to airbag deployment. Open the door locks. Lift the rollover protection system (ROPS) if equipped. Do not rush to disconnect the auxiliary battery 12 V. before the power seats adjust. Doing so may require the need to move the dashboard in certain situations. This can increase the time to rescue more than 30 minutes. Some hybrids have a label location batteries located in the engine compartment and under the hood. Responders should look for the label on the battery compartment located on the hood / for all locations of the battery. Notice: Note that it may not be necessary to carry out the battery disconnect low voltage 12 V. in each collision. As in conventional vehicles determination to disconnect the low voltage battery should be left to the discretion of the officer or incident commander.
The ERG Toyota -Lexus, as a matter of safety for emergency responders determined not trained or equipped with Personal Protective Equipment should not use the method of pulling the plug service for the emergency stop. However, alternative procedures are easier response methods have been developed, and do not require the use of rubber gloves high tension. Rescuers should consult the Toyota -Lexus ERG specific procedures for emergency stop.
This current is therefore responsible to keep the battery at full charge and when not consumed energy is used to compensate for self-discharge batteries. Disconnecting from Consumer Batteries for Low Voltage Alarms Signals the OFF CONSUMPTION BY LOW VOLTAGE BATTERY. The output switch-consumption by low battery voltage indicates an accumulator discharge close to 70% of its nominal capacity. If the battery voltage falls below the voltage value of maneuver consumption during off over a set time, disconnects consumption. This is to prevent point clear brief overload consumption.
The final charge voltage should be corrected for temperature. Controlled overcharging the battery will be allowed to prevent stratification electrolyte or for equalizing charges the uses of other regulators that use different strategies allow regulation as additional parameters, such as the state of charge of the battery. - The charge controllers are protected against short circuits in the consumer line. - The charge regulator is selected to overload is capable of withstanding without damage simultaneously, the maximum ambient temperature of. - Current line consumption 25% higher than the maximum load current consumption. - The charge controller should be protected against the possibility of accidental disconnection accumulator, with any load. Under these conditions, the regulator should ensure addition to their own protection, the connected loads. - Losses caused by the daily energy consumption of the regulatory conditions normal operation should be less than 3% of daily energy intake. - Reconnection voltages overcharge and over discharge are different from disconnection, or be timed to avoid disconnection - reconnection oscillations. - The charge controller must be labeled with at least the following information: Stress nominal (V), high current (A) Manufacturer (name or logo) and serial number, Polarity and terminal connections.
Disconnect Switch: Disconnect switches generally refer to disconnect switches high voltage nominal voltage of 1 kV or above. In the circuit, the disconnect switch having the function of insulation. More switches are used between all devices interrupt high voltage. Its working principle and structure are simpler. However, as they have a lot of uses, high operational reliability is required , which has great influence on the design , construction and safe operation of electrical substations and power plants . The logout link is not capable of extinguishing the arc, so it can only separate and close circuits when no load current. According to the method of installation, disconnect switches can be divided into indoor disconnect switches and disconnect switches external. The external disconnect switches can work in a bad environment and is resistant to corrosion from wind, rain, snow, dew, frost, ice and heavy dirty things. The disconnect switches are suitable for high voltage work outdoors and applies primarily to rural electric networks and rural - urban fringe areas with a large market. The disconnect switches are suitable for low-voltage low-end system voltage power distribution in the home construction and elsewhere. Energy core Co., Ltd. is a leading manufacturer in US disconnect switch. Besides disconnect switches, we also produce wind turbine generators (wind turbine), circuit breakers, disconnections, indoor vacuum circuit breakers and other products. These products are widely applied to wind generation, rural power grids, military activities, outdoor travel, research, field production, public places, residential buildings and other places. To learn more about our products, please feel free to contact us.
Dimensions: according closet in mm. Lower or higher depending closet Rush. Screens methacrylate against direct contact, even with the doors open. Constructive Standards: UNE -EN 60439 1-2 Modular rack for easy removal from 100 kVAr. Control circuit Control transformer 400/ 230 (attack only internal phase + earth from 60 kVAr). Halogen- frees wiring. Forced ventilation with turbine extractor and minimum thermostat from 100 kVAr to ensure air circulation inside the computer... Thermostat over temperature maximum safety, to avoid operation of the capacitors against high temperatures. Terminals for SIEMENS maneuver Alpha Fix model.
Three-phase low loss (W <0.45 W / kVAr including discharge resistor) and monophonic in triangle for teams below 100 kVAr. Impregnation: inert gas in condensers Phase cap (single market). Mineral oil impregnation capacitors phi cap Free of PCBs Extruded aluminum enclosure. It ensures appropriate ventilation along with the IP 31 standard and forced ventilation in closets. Ex-proof triple safety system. Mechanical fuses spark sheath. In self-healing Metalized polypropylene ramp. Internal Wiring concentric phase. Edge metalized polypropylene to improve chopado wave poles. Safety certification UL 810. UNE- EN 60831 1-2 Ballasts High linearity phase reactor. Class F. Working temperature 70 C Maximum temperature 155 C Auto by thermal over temperature. IP00.
Block for devices without pre-insertion reactors to limit the peak current voltage input. Fuses Siemens SITOR size NH00 model. Fuse SITOR Siemens series Power cut at least 100 kA. Protection according to UNE- EN 60831-1 1.5 In. Documentation Technical Manual developed according Decalogue quality. Fully automated and scheduled to start autonomous way, without technical assistance necessary equipment. Technical Assistance to business telephone sales and customer initially. Personal attention by displacement should be required for incidents and implemented.
Both of the above physical characteristics improve working temperature inside the condenser to reduce that thereof. Guarantee in the production of sealing capacitor to ensure the safe removal thereof by increasing pressure and displacement of the lid. It is checking all production by gas chromatograph to ensure the tightness. Some manufacturers allow the explosion of capacitor incorporating materials that liquefy off against heat and flame. In case of loss of these materials, there is no breach of rules anti defrag ante system. Triple -off system by mechanical fuses spark sheath within environment with SF6 (gas used in disconnections MT) that ensures the operation of explosion-proof system to 100x100. Some manufacturers allow the explosion (see above). Other cause an internal short for fusion of an internal fuse, not ensure an adequate level of ICC.
Battery Protection
The battery protector disconnects battery non-essential consumption, before it is completely discharged ensuring power needed to start the engine. Surge Protection to protect sensitive instruments surges, the battery is disconnected automatically when the voltage exceeds 16 or 32V. Contactless switching Static switches using MOSFETS relays instead of eliminating any risk of arc Electric. Alarm deferred action. An alarm contact is activated when the voltage battery is below the level established during over 15 seconds. Thus, any claim of high power, albeit short-lived (engine start), will not cause an alarm. The
alarm contact is a negative output normally open to a maximum intensity of 500mA can be used to activate a pilot and / or buzzer. Disconnecting deferred action The disconnect action is deferred to be occurs only in situations unchanged. This is necessary that the alarm is activated for more than one minute to cause disconnection. Yes during this period, the voltage rises (e.g. after merely to start the engine), there will be disconnection.
Thanks to technology MPPT , MPPT series can BlueSolar increase the charging current up to 30 % compared with conventional PWM controllers .
The sophisticated control system load into three stages BlueSolar can be configured to optimize load parameters according to the specific needs of the battery. The unit is fully protected Surge , overheat, overcurrent and reverse polarity of the battery and PV panels ( PV ) . a automatic current limiting option allows the use of all output current without worrying about overload or fuses fused due to overcurrent .
The Fully Automatic temperature compensation voltage load is available to further enhance control of the load and battery performance . The sensor element is environmentally sealed and encapsulated in a plastic sleeve which is bonded directly to the Battery terminal .
You can use multiple drivers in parallel for MPPT BlueSloar increase the charging current 1.2 Features Controller Tracking Maximum Power Point (MPPT, for its acronym in English). Increases current load up to 30%, compared with Controller points width modulation (PWM, for short English). Charging voltage parameters eight battery types, plus two parameters of equalization. Remote temperature sensor. Protected against overcurrent. Protected against short circuit. Protected against reverse polarity connection of the solar panels and / or battery. Disconnecting the output low voltage load. 4 load curve 4.1 Loads in three phases The BlueSolar MPPT charge controller is configured to carry
1) Initial Phase During this phase, the current controller supplies such load as he can to recharge the batteries quickly. When the battery voltage reaches the voltage of absorption default, the controller activates the next phase (absorption).
2) Absorption phase During this phase, the controller switches to voltage constant, which is applied to the absorption voltage battery. When the load current decreases to the current flotation default transition (about 0.3 A), the battery is fully charged and the controller switches to the flotation phase. 4 load curve 4.1 Loads in three phases The BlueSolar MPPT charge controller is configured to carry loading out in three phases Processes: Initial - Absorption - Flotation.
1) Initial Phase During this phase, the current controller supplies Such load as I can to recharge the batteries quickly. When the battery voltage of the voltage Reaches absorption default, the controller activates the next phase (absorption).
2) Absorption phase During this phase, the controller switches to voltage constant, que absorption is applied to the battery voltage. When the load current to the current Decreases flotation default transition (about 0.3 A), the battery is fully charged and the controller switches to the flotation phase. Preparation of load equalization : 1) Remove all DC loads connected to the batteries. 2) Remove all vent caps on the battery. 3) Check the water level in the battery, should be just above the plates ( not to overfill ) . Use only water distilled or demineralized water to fill the battery. 4) Set the SWITCH BATTERY TYPE "0" or "1" . 5) putting the SWITCH BATTERY TYPE back into the proper position when all the cells are fully loaded (this can be checked with a hydrometer ) . 6) NEVER EQUALIZE Valve Regulated Lead Acid (VRLA ) batteries ( Commonly called Gel or AGM batteries )
4.3 Battery Type Selector The battery type selector is a 10-position rotary switch used to set the proper voltage levels absorption, float and equalization. These levels are selected
depending on the type of battery used . See the following table load voltages of the different switch positions. See manufacturer battery optimum charging parameters for the same 00000000000000000000000000000000000000000000000000000000
: Local charge storage batteries electrical lead-sulfuric acid introduction Electric storage batteries lead acid sulfuric chemical energy stored during the loading operation and returned in the form of electrical energy for use in different applications. A battery is comprised of a container containing a set of elements consisting of positive and negative plates immersed in an electrolyte which is a sulfuric acid solution in water . A battery is characterized by its ability to store electricity in ampere-hours ( A- hr ) and the voltage in volts ( V ) . The most common are 12 V and with various capacities depending on the use to which they are intended . Connected in series the voltages required are obtained. Are used as power source in vehicles transportation, construction equipment , forklifts , generators, power plants, etc. . After a given airtime deplete its charge and require recharging. This operation can be repeated many times and is due on safely . Risks battery operations Potential risks from multiple transactions have to be carried out are: Risk contact projection highly corrosive sulfuric acid , being more serious in the case of explosion with breakage of the battery container . Risk of contact with the electrical current in the use of loading equipment .
Risk of explosion caused by the evolution of hydrogen and oxygen in the presence of an ignition source . this release the battery is weak to stand or download but reaches its maximum value at the end of the load and especially if subjected to an overload . The generation of these gases is continued for about one hour after disconnecting the load current . Mechanical hazards drop heavy objects on the foot and overexertion in manual handling operations and mechanics. Risk of tripping over wires or objects crossing sites hygienic risks through inhalation of aerosols of sulfuric acid. Hydrogen evolution Hydrogen is an extremely flammable gas and if found in concentrations of flammable range or explosive in an enclosure, there is a risk of explosion in the presence of any source of ignition. Hydrogen evolution and oxygen takes place in the electrolysis reaction of water during the final stage of charging and especially if overload occurs . should avoid concentration reaches the lower explosive limit of hydrogen , which is 4 % by volume in air. Should be checked The NTP is good practice guides . Its indications are not binding unless they are contained in a provision regulations. In order to assess the relevance of the recommendations contained in a particular NTP is convenient regardless of their date of issue. Year: 200 load and adjust the intensity supplied charger ? . Before performing any operation on a battery that has been charged, it is recommended to leave at least an hour and the plugs removed , airing each cell with a gentle stream of air provided with a rigid cardboard as a fan or other nonconductive material to avoid the risk of contact with the terminals and the resulting spark as discussed in paragraph
following . The blast may be external to the battery if the accumulation of hydrogen occurs in the local load and also in the interior of the battery easily where the concentration is in the explosion range (4 to 79%). Breakage of the lead box acid projected onto the operator . A concentration area in the vicinity of the battery is defined as a finite volume above the caps , within which it is possible to ignite the explosive mixture. The height and width of that danger zone depends on the flow of gas detached . This definition assumes the existence of ventilation in the room, as if with Conversely the concentration of hydrogen would increase throughout its volume with the risk of explosion.
Control of ignition sources Among the sources or ignition sources to avoid possible presence are cited : Matches or lighters used to watch the electrolyte level by adding holes distilled water. Flames welding or cutting torches . These operations must be performed in remote locations and set permissions special jobs . Sparks from welding equipment arc. As in the previous case . short circuit sparks with tools or metal objects that come in contact with the battery terminals . Can be avoid covering the terminals with insulating cap and use insulated tools . Sparks caused when installing or removing a battery of a vehicle while the current flowing through the battery circuit . To avoid all vehicle equipment (radio , lights , fans, etc. . ) Must be disconnected . The smallest consumption as the interior lights of a vehicle can generate a spark at the point where it interrupts the circuit. Smoking cigarettes . Should be prohibited.
Sparks in connecting or disconnecting the battery with the charger. It should do the job switch charger disconnected. If he has that switch , the charger should be unplugged from the outlet AC before connecting or disconnecting the battery to the charger. Connectors must bring their polarities marked for avoid confusion and damage to the battery . Sparks to remove the cable from the positive terminal of the battery of a vehicle if it takes the negative ground pole. The wrench or sets used in the operation may make contact with a metal body or engine ground. This prevents first removing the negative cable is grounded. When installing the battery in the vehicle must be first connect the cable is not earthed (if exposed positive ) . The grounding cable should be with