You are on page 1of 36

CHINESPORT GENERAL CATALOGUE - EDITION 2013

Electro-medical Equipment
50 Introduction 52 Electrotherapy 57 Vacuum Therapy 58 Ultrasound Therapy 62 Combined Therapies 66 Laser Therapy 69 Scanning Laser Therapy 72 High Power Laser Therapy 75 Magneto Therapy 78 Radar Therapy 79 Pressure Therapy 80 Shock Wave 82 TECAR cellular regenerator 84 Thermotherapy

Introduction
In this section Chinesport presents its new range of electromedical devices, divided in three product lines, BASIC, PLUS and EXCELLENT for:

Electro therapy Ultrasound therapy Combined therapies Laser therapy Magneto therapy Radar therapy Pressure therapy Shock wave Vacuum therapy

Europea e riconosciuta a livello Internazionale 0476

Certificazione richiesta dalla Comunit

A new advanced equipment called T-CARE completes our range of electromedical devices. It consists of a ResistiveCapacitive Energy Transmission along with an Integrated Transdermal Transport by means of a patented handpiece. TECAR therapy represents currently one of the most requested and cost-effective therapy for rehabilitation in Italy and other countries.
THERAPEUTIC INDICATIONS:
Muscular injuries Joint capsulitis Distortions Cervicalia Bone and ligament trauma Tendon injuries and bursitis Lumbalgia and ischialgia Myositis Arthrosis processes Rehabilitation programmes

Tot Di Natale striker of the soccer club Udinese, Italian Premier League and Italian National Team, best scorer 2009/2010 and 2010/2011. Treatment with the TCARE device of Chinesport spa - Italy.

50

www.chinesport.com

Introduction

Made in Italy

2
Basic Line
LCD DISPLAY The Basic Line comes with a 240x64 dpi graphic display that ensures clear displaying of all the most important information. EASY TO USE One fundamental aspect in using electro-medical equipment on a daily basis, is how easy it is to use. This has proved to key to designing this line and it has also allowed us to simplify how each piece of equipment works. MULTIPLE LANGUAGE SOFTWARE All the machines in the Basic Line have operating software in 5 languages: Italian, English, French, German and Spanish - which can be switched by the user as they please. INTERNAL MEMORY All our machines have an internal memory that has 20 protocols saved in it, with scope for saving up to 10 new working protocols.

Plus Line
LCD DISPLAY The ample LCD screen measures 6 inches diagonally and has a resolution of 320x240 dpi, providing a clear, easy to understand display of all the most important information. THE MICROPROCESSOR The heart of the machine is a new, powerful microprocessor that has 3 times more computing power than that normally required by the operating system, thereby overcoming any possible work overload. Only 25% of the builtin memory is used, so that the machine can be updated in the future, by adding functions not included in the original version MULTIPLE LANGUAGE SOFTWARE All machines come with standard operating software in 5 languages: Italian, English, French, Spanish and German- which can be switched by the user as they please. INTERNAL MEMORY All our machines have an internal memory, with scope for saving up to 200 new working protocols. SMART CARD The built-in memory-card reader increases the machines power to the maximum, providing the following services: Possibility of using memory cards with new working protocols. Possibility of creating cards that are customised for the client, on which the relevant treatment can be recorded. Possibility of saving new work protocols.

Excellent Line
TOUCH SCREEN COLOUR MONITOR A 6 colour display, with touch screen function. All therapeutic applications can be activated by a simple touch. . PROGRAMS IN THE MEMORY All the equipment in the Excellent Line has applications that are selected and checked scientifically, thereby providing a vast library of working protocols. MULTIPLE LANGUAGE SOFTWARE All the machines in the Excellent Line have operating software in 5 languages: Italian, English, French, German and Spanish - which can be switched by the user as they please. SELECTION BY ANATOMICAL PARTS When the part of the body to be treated is selected, a list of localised protocols can be accessed. This system makes it easier to use the various working protocols stored in our equipment. ONLINE HELP The protocols in the memory include instructions on using them and direct access to the therapy also provides a display that shows the exact positioning of the electrodes. MP3 Therapy as a time of relaxation. Finally, one can now also listen to relaxing music during treatment to spend all your time with your own soundtrack. In addition to various files already in the system, you can also add your own music files. SMART CARD A distinctive feature of the equipment is the Smart Card, a memory outside the machine that makes it possible to create customised cards for clients, on which the relevant therapy is recorded.

51

Electrotherapy - Introduction
Electro therapy uses the biological effects that can be obtained using electricity for therapeutic purposes, and involves electric currents that are passed through the relevant part of the body, being careful to choose them with specific characteristics that are suitable for the purposes to be achieved. Electro therapy is used to stimulate denervated muscles, to reduce hypotrophy due to non-use of a normoinnervated muscle, and to maintain muscular trophicity of denervated or partially innervated muscles, in order to strengthen the innervated muscle. The principal effects of electric current applied to body tissue include motory activation, thermal, trophic, analgesic, and chemical effects. Each muscular stimulation electric impulse is characterised by: Wave frequency: measured in Hz (hertz) Wave width: measured in msec (milliseconds) Intensity: measured in mA (milliampere) PRINCIPAL EFFECTS OF ELECTRICAL STIMULATION 1) Training the neuro-muscular system to respond appropriately during voluntary and involuntary effort, providing an active (isometric, concentric, and eccentric) contraction and the resulting articular movements, providing proprioceptive feedback. 2) Modulation of pain by means of the gate control mechanisms or descending inhibition mechanisms (production of endogenic opioides). 3) Control or reduction of spasticity by stimulating (contraction and relaxation) agonists, (reciprocal inhibition) antagonists, or prevention of motorial sensation. 4) Providing transdermal releasing of medicamentosus substances in the skin (iontophoresis). 5) Improving or maintaining articular mobility by mechanical stretching of muscles or connecting tissue or reducing impediment to movement, caused by neuromuscular dysfunctions (e.g. spasticity), pain or oedema. 6) Facilitating healing of wounds by increasing local circulation, providing a bacterial effect, or changing the electric charges in the injured area. 7) Slowing down or resolving oedema by the activity of the muscular pump or the effect of the electric charges on the interstitial proteins (electric field phenomena).

ACCESSORIES

EL0009

SPONGES 7X6 CM

el0011

Set of 2 pieces

ELECTRODES 5 X 5 CM

el0013

Set of 2 pieces

elastic straps 60 cm

Set of 2 pieces

EL0010

SPONGES 7X11 CM

el0012

Set of 4 pieces

ELECTRODES 6 X 8 CM

el0014

Set of 4 pieces

elastic straps 100 cm

Set of 2 pieces

el12003
TROLLEY

Trolley with tabletop and possibility of fixing nonwheeled electromedical equipment and the arms.

el0015

OUTPUT CABLE

el0082
link cable

This cable is used for connecting electro therapy and ultrasound equipment.

el0016
CASE

el0001

PERSONAL SMART CARD

el12005

10 pcs pack to program the patients rehabilitation protocol, so as to facilitate and expedite the operating time of the equipment.

UROLOGY PROGRAM KIT

This kit consists of: 2 probes and two rings (1 vaginal and 1 anorectal) for KOMBI and MEDIC STIM models.

el12004

VACUUM THERAPY

Connection with the electrical therapy units is possible. See also the specific product presentation.

52

www.chinesport.com

Electrotherapy - BasicLine
el12050 medicstim basic
Electro therapy equipment with 2 independent channels, providing low and medium frequency current, for a total of 23 wave forms. ACCESSORIES SUPPLIED
Power cable Fuses 315mA-T 6x8 cm electrodes Electrode sponges 7x11 cm 5x5 cm electrodes Electrode sponges 7x6 cm 100 cm elastic band 60 cm elastic band Electro therapy output cable 1 2 4 4 4 4 2 2 1

Made in Italy

WAVE FORMS PROVIDED


Galvanic Diadynamic Impulses Faradic Tens Biphasic Interferential continuous; interrupted; MF single-phase; diphase; sync. single-phase; sync. diphase; Short Period; Long Period rectangular; triangular; traebert rectangular; triangular; neodynamic burst; random; modulated symmetric; asymmetric classical; iso-planar; vectorial; Russian current (Kotz)

ACCESSORIES EL0009 SPONGES 7X6 CM EL0010 SPONGES 7X11 CM el0011 ELECTRODES 5 X 5 CM el0012 ELECTRODES 6 X 8 CM el0013 elastic straps 60 cm el0014 elastic straps 100 cm el0015 OUTPUT CABLE el0016 CASE el0082 link cable el12003 TROLLEY el12004 VACUUM THERAPY el12005 UROLOGY PROGRAM KIT

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: Double delay type (T) mains fuse protection: 230 Vac 115 Vac Backlit LCD display, to view and check the operating parameters Programmable treatment time Emission frequency Operation: DIADYNAMIC currents Load resistance 1KOhm Peak currents with other waveforms Peak voltage Output channels Stored protocols Storable protocols Table container in plastic, external size (width x height x depth) Unit body weight
* upon request

230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 30 VA 315 mA T - 5 x 20 mm 630 mA T - 5 x 20 mm graphics 240 x 64 pixel up to 60 minutes 23 waveforms (All low and medium frequency currents) Constant voltage Constant current 50 mA 70 mA 100 mA 100 V 2 20 10 39 x 13 x 32 cm 4,2 Kg

53

Electrotherapy - PlusLine
el12053 medicstim 2 complet el12054 medicstim 4 complet
Equipment with 2 channels, with all low and medium frequency wave forms. Equipment with 4 channels, with all low and medium frequency wave forms. ACCESSORIES SUPPLIED
Power cable Fuses 315mA-T 6x8 cm electrodes Electrode sponges 7x11 cm 5x5 cm electrodes Electrode sponges 7x6 cm 100 cm elastic band 60 cm elastic band Electro therapy output cable Smart card

el12053
1 2 4 4 4 4 2 2 1 1

el12054
1 2 8 8 8 8 4 4 2 1 Included Smart Card

WAVE FORMS PROVIDED


Galvanic Diadynamic Impulses Faradic Tens Biphasic Interferential continuous; interrupted; MF single-phase; diphase; sync. single-phase; sync. diphase; Short Period; LP (long period) rectangular; triangular; traebert rectangular; triangular; neodynamic burst; random; modulated; at tens symmetric; asymmetric quadripolar, iso-planar; vectorial; bipolar; stimulating: Russian current (Kotz)

Creation of I/T Rheobase and Chronaxy curve

ACCESSORIES el0001 PERSONAL SMART CARD EL0009 SPONGES 7X6 CM EL0010 SPONGES 7X11 CM el0011 ELECTRODES 5 X 5 CM el0012 ELECTRODES 6 X 8 CM el0013 elastic straps 60 cm el0014 elastic straps 100 cm el0015 OUTPUT CABLE el0016 CASE el0082 link cable el12003 TROLLEY el12004 VACUUM THERAPY el12005 UROLOGY PROGRAM KIT

54

www.chinesport.com

Electrotherapy - PlusLine
TECHNICAL SPECIFICATIONS
Mains power supply: Medicstim 4 Complet Medicstim 2 Complet Medicstim 4 Complet Double delay type (T) mains fuse protection: Medicstim 2 Complet Backlit LCD display, to view and check the operating parameters Programmable treatment time Maximum power absorbed from the mains: Electrical insulation class / applied parts in compliance with the UNI EN 60601-1 standard Device class in compliance with the 93/42/CEE directive Degree of protection against the input of liquids according to the UNI EN 60601-1 standard Emission frequency Waveform families number in the device Waveforms total number in the device Operation: Peak currents (Load resistance 1KW) Medicstim 4 Complet Medicstim 2 Complet Medicstim 4 Complet Medicstim 2 Complet Medicstim 4 Complet Medicstim 2 Complet Medicstim 4 Complet Medicstim 2 Complet Pulsed currents DIADYNAMIC currents Direct currents IONOPHORESIS Pulsed currents DIADYNAMIC currents Direct currents IONOPHORESIS Medicstim 4 Complet Medicstim 2 Complet 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 65 VA 30 VA

Made in Italy

315 mA - T - 5 x 20 mm for 230Vac supply 630 mA - T - 5 x 20 mm for 115Vac supply graphics 320 x 240 pixel up to 60 minutes I / BF II B IPX0 All low and medium frequency currents 23 30 Constant voltage Constant current 100 mA 70 mA 50 mA 100 mA 70 mA 50 mA 4 independents 2 independents 50 200 10 100 100 40 10 20 10 39 x 13 x 32 cm 5,2 Kg 4,6 Kg (+10: +40) C (10: 80) % without condensation (-40: +70) C (10: 100) % without condensation (500: 1060) hPa

Peak voltage (Load resistance 1KW) Output channels

Stored protocols Protocols storable in the user memory Sequences storable in the user memory I/t Curves storable in the user memory reobase/cronaxya values storable in the user memory Protocols storable in the smart-card Sequences storable in the smart-card I/t Curves storable in the smart-card reobase/cronaxya values storable in the smart-card Table container in plastic, external size (width x height x depth) Medicstim 4 Complet Unit body weight Medicstim 2 Complet Room temperature Conditions for use Relative humidity Room temperature Conditions for stocking / transport Relative humidity Atmospheric pressure
* upon request

55

Electrotherapy - ExcellentLine
el12084 medicstim EXCELLENT
ACCESSORIES SUPPLIED
Power cable Fuses 315mA-T 6x8 cm electrodes Electrode sponges 7x11 cm 5x5 cm electrodes Spugna per 6x8 cm electrodes 100 cm elastic band 60 cm elastic band Display Pointer Electro therapy output cable Smart card 1 2 4 4 4 4 2 2 1 1 1 Included Smart Card

Electro therapy equipment with 2 independent channels.

WAVE FORMS PROVIDED


Galvanic Diadynamic Impulses Faradic Tens Biphasic Interferential continuous; interrupted; MF single-phase; diphase; sync. single-phase; sync. diphase; Short Period; LP (long period) rectangular; triangular; traebert rectangular; triangular; neodynamic burst; random; modulated; at tens symmetric; asymmetric quadripolar, iso-planar; vectorial; bipolar; stimulating: Russian current (Kotz)

Micro currents - High Voltage HVPC - H Waves - APS - Creation of I/T Rheobase and Chronaxy curve

ACCESSORIES el0001 PERSONAL SMART CARD EL0009 SPONGES 7X6 CM EL0010 SPONGES 7X11 CM el0011 ELECTRODES 5 X 5 CM el0012 ELECTRODES 6 X 8 CM el0013 elastic straps 60 cm el0014 elastic straps 100 cm el0015 OUTPUT CABLE el0016 CASE el0082 link cable el12003 TROLLEY el12004 VACUUM THERAPY el12005 UROLOGY PROGRAM KIT

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: Double delay type (T) mains fuse protection: Backlit LCD display, to view and check the operating parameters Programmable treatment time Electrical insulation class / applied parts in compliance with the UNI EN 60601-1 standard Device class in compliance with the 93/42/CEE directive Degree of protection against the input of liquids according to the UNI EN 60601-1 standard Emission frequency All low and medium frequency currents Operation: Pulsed currents Peak currents (Load resistance 1Kohm) DIADYNAMIC currents Continuous currents Pulsed currents Peak voltage (Load resistance 1Kohm) DIADYNAMIC currents Continuous currents Independents output channels Stored protocols in the user memory Storable protocols in the smart-card Storable protocols Table container ( base in metallic material , cover in plastic material ), external dimensions Unit body weight Room temperature Conditions for use Relative humidity Room temperature Conditions for stocking / transport Relative humidity Atmospheric pressure * upon request 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 35 VA 315 mA - T - 5 x 20 mm for 230Vac supply 630 mA - T - 5 x 20 mm for 115Vac supply graphics 320 x 340 pixel TOUCH SCREEN up to 60 minutes I / BF II B IPX0 32 waveform families - 39 waveform in total Constant voltage - Constant current 100 mA 70 mA 50 mA 100 mA 70 mA 50 mA 2 200 50 100 39 x 13 x 32 cm 4,7 Kg (+10: +40) C (10: 80) % without condensation (-40: +70) C (10: 100) % without condensation (500: 1060) hPa

56

www.chinesport.com

Vacuum Therapy
Vacuum therapy is a method that uses the effect of vacuum on the body, combining improvement in micro circulation in the tissue with an anti-inflammatory and detoxifying action. Essentially the therapy consists of applying an airtight chamber to a part of the body, in which a vacuum is formed, followed by compression to activate venous and lymphatic circulation. This generates a suction cup effect that causes increased blood flow in the area, stimulating circulation and oxygenation, speeding up the exchange of substances and the elimination of toxins. This results in a substantial increase in oxygen levels in the peripheral tissue and a reduction in carbon dioxide, it speeds up the flow of blood and even counteracts venous stasis, which is the basis of varicose veins and related venous insufficiency. Applying vacuums along with stimulating currents is done using vacuum electrodes. These electrodes are connected by means of hoses to a suction pump that induces a negative pressure inside the electrodes themselves. When this occurs the extensive vacuum draws a large quantity of blood (hyperemia), improving the therapeutical effect by means of the various stimulation currents.

Made in Italy

el12004 vacuum therapy

Easy to use vacuum therapy equipment.

ACCESSORIES SUPPLIED
Power cable Users manual 6 cm vacuum cups 6 cm cup sponges Output cables Connection cable Electro therapy 1 1 4 8 4 1 1

CHARACTERISTICS
Suction Impulses per minute Power supply Absorption Dimensions Weight 0 - 0.6 bar 10 - 100 230V 50/60 Hz 40 VA cm 33 x 38 x 12h 6.5 kg

THERAPEUTIC INDICATIONS Arteriosclerosis of the lower limbs Burger Raynaud Forms with venous / lymphatic insufficiency: Swollen legs Lymphedema Phlebolymphedema Cellulite

accessorY

13125

TROLLEY 3 Collapsible steel tube structure, painted white, with 4 pivoting wheels. 3 white dual laminate shelves with rounded corners. cm 41 x 66 x 85h

57

Ultrasound Therapy Introduction


Ultrasounds are high frequency sound vibrations that cannot be perceived by the human ear. In the therapeutic field, the application of ultrasounds to human tissue provides a cellular and inter-cellular high frequency massaging action. Also, ultrasounds can also be used under water. The head is immersed in water along with the area to be treated. The tissue irradiated by ultrasounds vibrate in turn, resulting in energy being released, which produces heat. This summarised the biological effects of ultrasounds - a mechanical and diathermal effect: The Mechanical effect: is produced by the rhythmic compression and decompression of tissue. The particles in tissue covered by the vibrating band are all activated alternately, with the same acceleration and speed. The Diathermal mechanism: with possible biological effects begins to be possible at energy levels of 1 Watt/cm. As the sound is propagated through the tissues it is absorbed and converted into heat. The distribution of the temperature produced by the ultrasound in the tissues, is unique among the various forms of deep heating: in fact, it brings about an increase in temperature that is relatively small on the surface of the tissue and is more likely to penetrate the muscles and soft tissue than diathermia produced by microwaves or short circuits. Chemical effects: associated with a characteristic phenomenon induced by the ultrasounds - cavitation - that acts on the liquid components of the tissue where small gas bubbles tend to increase in size, which translates into processes of oxidation, polymerisation, destruction of macro molecules, etc. THERAPEUTIC EFFECTS The therapeutic effects of ultrasounds are partly due to the increase in temperature. These take the form of analgesia, relaxation of the muscles, and a fibrolytic and trophic effect. Analgesia - The analgesic effect is due to the heat, and probably also the direct action of the ultrasounds on the sensitive nerve endings. Relaxation of contracted muscles - Relaxation of contracted muscles is associated with the thermal effect and micro massaging of the tissue, induced by the passage of the ultrasounds. Fibrolytic effect - Oscillation of the tissue particles, caused by the ultrasounds, results in disruption of the collagen fibres in fibrous and sclerotised tissue. Trophic effect - Vasodilation, which results from a rise in temperature, facilitates the removal of catabolites and puts nutritive substances and oxygen into the tissue. In this way ultrasounds improve trophism of the tissue, facilitate repair of tissue damage and speed up resolution of inflammatory processes.

ACCESSORIES
el0017 el0018
HANDPIECE cm 1

el0019 el0020

1-3 MHz dual frequency

HANDPIECE cm 5

1-3 MHz dual frequency

HANDPIECE cm 3

1-3 MHz dual frequency

HANDPIECE cm 8

1-3 MHz dual frequency

el0021
SONIC ARM

el0023
GEL BOTTLE

For all handpieces. Possibility of fixing to trolley (code EL12003)

Electroconductive gel 250 g

el0024
GEL CAN

el0022

SONIC P ARM

Electroconductive gel 5 kg

Pantograph type. Free fixing

el0025
dispenser

For can (code EL0024)

el12003
TROLLEY

el0016
CASE

Trolley with tabletop and possibility of fixing nonwheeled electromedical equipment and the arms.

el0082
link cable

This cable is used for connecting electro therapy and ultrasound equipment.

el0001

PERSONAL SMART CARD

10 pcs pack to program the patients rehabilitation protocol, so as to facilitate and expedite the operating time of the equipment.

58

www.chinesport.com

Ultrasound Therapy - BasicLine


el12055 sonic basic
Table-top ultrasound therapy equipment, with 1 output, complete with 1/3 MHz multi-frequency handpiece

Made in Italy

ACCESSORIES SUPPLIED
Power cable Fuses 630 mA-T 1/3 MHz handpiece 5 cm2 1 2 1

ACCESSORIES el0016 CASE el0017 HANDPIECE cm 1 el0018 HANDPIECE cm 3 el0019 HANDPIECE cm 5 el0020 HANDPIECE cm 8 el0021 SONIC ARM el0022 SONIC P ARM el0023 GEL BOTTLE el0024 GEL CAN el0025 dispenser el0082 link cable el12003 TROLLEY

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: Double delay type (T) mains fuse protection: 230 Vac 115 Vac 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 40 VA 630 mA Rit. - 5 x 20 mm 1.6 A Rit. - 5 x 20 mm graphics 240 x 64 pixel up to 30 minutes I / BF II B IPX0 1 MHz and 3 MHz 15% 10% - 90% 2 W / cm 20% 3 W / cm 20% 1 20 10 39 x 13 x 32 cm 3,6 Kg Room temperature Relative humidity Room temperature Conditions for stocking / transport * upon request Relative humidity Atmospheric pressure (+10: +40) C (10: 80) % without condensation (-40: +70) C (10: 100) % without condensation (500: 1060) hPa

Backlit LCD display, to view and check the operating parameters Programmable treatment time Electrical insulation class / applied parts in compliance with the UNI EN 60601-1 standard Device class in compliance with the 93/42/CEE directive Degree of protection against the input of liquids according to the UNI EN 60601-1 standard Emission frequency Duty Cycle adjustable Continuous peak power Pulsed peak power Output channels Stored protocols Storable protocols in the user memory Table container (base in metallic material, cover in plastic material), external dimensions: Unit body weight Conditions for use

59

Ultrasound Therapy - PlusLine


el12056 sonic 1
Single output ultrasound therapy equipment. Water-resistant probe equipped with contact automatic sensor, with visual and sound signal.

el12057 sonic 2

Ultrasound therapy equipment with two independent outputs

ACCESSORIES SUPPLIED
Power cable Fuses 630 mA-T 1/3 MHz handpiece 5 cm Smart card

EL12056
1 2 1 1

el12057
1 2 2 1 Included Smart Card

ACCESSORIES el0001 PERSONAL SMART CARD el0016 CASE el0017 HANDPIECE cm 1 el0018 HANDPIECE cm 3 el0019 HANDPIECE cm 5 el0020 HANDPIECE cm 8 el0021 SONIC ARM el0022 SONIC P ARM el0023 GEL BOTTLE el0024 GEL CAN el0025 dispenser el0082 link cable el12003 TROLLEY

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: 11 5 Vac Double mains fuse protection: 230 Vac Backlit LCD display, to view and check the operating parameters Programmable treatment time Electrical insulation class /applied parts in compliance with the UNI EN 60601-1 standard Device class in compliance with the 93/42/CEE directive Degree of protection against the input of liquids according to the UNI EN 60601-1 standard Emission frequency Duty Cycle adjustable Continuous peak power Pulsed peak power Output channels Stored protocols Storable protocols in the Smart Card Storable protocols in the user memory Table container, external dimensions (width x height. x depth): Unit body weight Conditions for use Sonic 2 Sonic 1 Room temperature Relative humidity Room temperature Conditions for stocking / transport * upon request Relative humidity Atmospheric pressure Sonic 2 Sonic 1 Sonic 2 Sonic 1 Sonic 2 Sonic 1 Sonic 2 Sonic 1 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 70 VA 40 VA 2 A-T - 5 x 20 mm 1.6 A-T - 5 x 20 mm 1 A-T - 5 x 20 mm 630mA-T - 5 x 20 mm graphics 320 x 240 pixel up to 60 minutes I / BF II B IPX0 1 MHz and 3 MHz 15% 10% - 100% 2 W / cm 20% 3 W / cm 20% 2 independents 1 60 200 200 39 x 13 x 32 cm 4,25 Kg 4,20 Kg (+10: +40) C (10: 80) % without condensation (-40: +70) C (10: 100) % without condensation (500: 1060) hPa

60

www.chinesport.com

Ultrasound Therapy - ExcellentLine


Ultrasound equipment with two independent channels and three frequencies: 1,2 and 3 MHz, in both continuous and pulsating mode. Water-resistant probe equipped with contact automatic sensor, with visual and sound signal.

Made in Italy

el12085 sonic excellent

ACCESSORIES SUPPLIED
Power cable Fuses 315mA-T 1/3 MHz handpiece 5 cm Display Pointer Smart card 1 2 1 1 1 Included Smart Card

ACCESSORIES el0001 PERSONAL SMART CARD el0016 CASE el0017 HANDPIECE cm 1 el0018 HANDPIECE cm 3 el0019 HANDPIECE cm 5 el0020 HANDPIECE cm 8 el0021 SONIC ARM el0022 SONIC P ARM el0023 GEL BOTTLE el0024 GEL CAN el0025 dispenser el0082 link cable el12003 TROLLEY

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: Double mains fuse protection: 115 Vac 230 Vac 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 70 VA 1 A -T - 5 x 20 mm 2 A-T - 5 x 20 mm Graphics 320 x 340 pixel TOUCH SCREEN up to 30 minutes I / BF II B IPX0 1 MHz 15% Emission frequency Duty Cycle adjustable Continuous peak power Pulsed peak power Output channels Stored protocols Storable protocols in the Smart Card Storable protocols in the user memory Table container, external dimensions (width x height. x depth): Unit body weight Conditions for use Room temperature Relative humidity Room temperature Conditions for stocking / transport * upon request Relative humidity Atmospheric pressure 2 MHz 15% 3 MHz 15% 10% - 90% 2 W / cm 20% 3 W / cm 20% 2 independents 91 250 250 39 x 13 x 32 cm 6,55 Kg (+10: +40) C (10: 80) % without condensation (-40: +70) C (10: 100) % without condensation (500: 1060) hPa

Backlit LCD display, to view and check the operating parameters Programmable treatment time Electrical insulation class /applied parts in compliance with the UNI EN 60601-1 standard Device class in compliance with the 93/42/CEE directive Degree of protection against the input of liquids according to the UNI EN 60601-1 standard

61

Combined Therapies - BasicLine


el12058 komby basic
Equipment for combined therapy - one channel for 1/3 MHz ultrasound therapy and electro therapy with 2 independent channels and 16 wave forms. In ultrasound therapy, a sensor allows the energy to be supplied only when there is contact with the patient, sending the operator a visual and auditory feedback. In electrotherapy, instead, the microcontrollers to the power boards verify in real time that the selected current is deliver correctly and report any possible anomalies. ACCESSORIES SUPPLIED
Power cable Fuses 630 mA-T 6x8 cm electrodes 5x5 cm electrodes Electrode sponges 7x6 cm Electrode sponges 7x11 cm 100 cm elastic band 60 cm elastic band 1/3 MHz handpiece 5 cm2 Electro therapy output cable 1 2 4 4 4 4 2 2 1 1

WAVE FORMS PROVIDED


Galvanic Impulses Faradic Tens Biphasic Interferential continuous; interrupted; MF rectangular; triangular; traebert rectangular; triangular; neodynamic burst forms; random; modulated symmetric; asymmetric classical; iso-planar; vectorial; Russian current (Kotz)

ACCESSORIES EL0009 SPONGES 7X6 CM EL0010 SPONGES 7X11 CM el0011 ELECTRODES 5 X 5 CM el0012 ELECTRODES 6 X 8 CM el0013 elastic straps 60 cm el0014 elastic straps 100 cm el0015 OUTPUT CABLE el0016 CASE el0017 HANDPIECE cm 1 el0018 HANDPIECE cm 3 el0019 HANDPIECE cm 5 el0020 HANDPIECE cm 8 el0021 SONIC ARM el0022 SONIC P ARM el0023 GEL BOTTLE el0024 GEL CAN el0025 dispenser el0082 link cable el12003 TROLLEY

62

www.chinesport.com

Combined Therapies - BasicLine


TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: Double mains fuse protection: 230 Vac 115 Vac 230 Vac, 50-60Hz, 10%

Made in Italy

115 Vac, 50-60Hz, 10% * 60 VA 630 mA Rit. - 5 x 20 mm 1.6 mA Rit. - 5 x 20 mm Graphics 240 x 64 pixel 20 50 -Electrotherapy Sectionup to 60 minutes Low and medium frequency currents 16 waveforms Continuous / Pulsed Constant Voltage Constant Current 8 kHz max 50 mA 100 mA 100 V 2 independents -Ultrasound Sectionup to 30 minutes 1 MHz and 3 MHz 15% 10% - 100% 2 Hz 2 W / cm 20% 3 W / cm 20% TV1 probe Max 5 : 1 Max 5 : 1 Max 5 : 1 Max 5 : 1 1 IIB I / BF IPX0 39 x 13 x 32 cm 7,2 Kg TV3 probe TV5 probe TV8 probe

Backlit LCD display, to view and check the operating parameters Stored protocols Storable protocols Programmable treatment time Emission frequency Typology of waveforms Operation Emission frequency Direct currents -IONOPHORESIS- (Load resistance 1KOhm) Peak currents with other waveforms (Load resistance 1KOhm) Peak voltage (Load resistance 1KOhm) Output channels Programmable treatment time Emission frequency Duty Cycle adjustable Duty-Cycle Frequency Continuous peak power Pulsed peak power

Beam Non uniformit Ratio ( BNR )

Output channels Device class in compliance with the 93/42 directive Electrical insulation class / applied parts in compliance with the UNI EN 60601-1 standard Degree of protection against the input of liquids according to the UNI EN 60601-1 standard Table container in plastic, external size (width x height x depth) Unit body weight * upon request

63

Combined Therapies - PlusLine


el12059 komby
Equipment for combined therapy - one channel for 1/3 MHz ultrasound therapy and electro therapy with 2 independent channels and 16 wave forms. In ultrasound therapy, a sensor allows the energy to be supplied only when there is contact with the patient, sending the operator a visual and auditory feedback. In electrotherapy, instead, the microcontrollers to the power boards verify in real time that the selected current is deliver correctly and report any possible anomalies.

ACCESSORIES SUPPLIED
Power cable Fuses 630 mA-T 6x8 cm electrodes 5x5 cm electrodes Electrode sponges 7x6 cm Electrode sponges 7x11 cm 100 cm elastic band 60 cm elastic band 1/3 MHz handpiece Electro therapy output cable Smart card 1 2 4 4 4 4 2 2 1 1 1 Included Smart Card

ACCESSORIES el0001 PERSONAL SMART CARD EL0009 SPONGES 7X6 CM EL0010 SPONGES 7X11 CM el0011 ELECTRODES 5 X 5 CM el0012 ELECTRODES 6 X 8 CM el0013 elastic straps 60 cm el0014 elastic straps 100 cm el0015 OUTPUT CABLE el0016 CASE el0017 HANDPIECE cm 1

el0018 HANDPIECE cm 3 el0019 HANDPIECE cm 5 el0020 HANDPIECE cm 8 el0021 SONIC ARM el0022 SONIC P ARM el0023 GEL BOTTLE el0024 GEL CAN el0025 dispenser el0082 link cable el12003 TROLLEY

64

www.chinesport.com

Combined Therapies - PlusLine


TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: Double mains fuse protection: 230 Vac 115 Vac 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 65 VA 630 mA Rit. - 5 x 20 mm 1.6 mA Rit. - 5 x 20 mm Graphics 320 x 240 pixel 25 + 25 + 16 -Electrotherapy SectionProgrammable treatment time Operation Waveforms Peak current (Load resistance 1KOhm): Peak voltage (Load resistance 1KOhm): Storable protocols Storable protocols in user memory Storable protocols in smart-card Curbe I/t stored in user memory Curbe I/t stored in smart-card Outputs -Ultrasound SectionProgrammable treatment time Emission frequency Duty Cycle adjustable Duty-Cycle Frequency Continuous peak power Pulsed peak power Storable protocols Storable protocols in user memory Storable protocols in smart-card Outputs -Combined SectionProgrammable treatment time Current type Emission frequency Adjustable Duty-Cycle Continue peak power Pulsed peak power Stored protocols Outputs Insulation class / applied parts according to EN 60601-1 standard Classification according to directive 93/42/EEC Degree of protection against input of liquids according to EN 60601-1 standard Table container in plastic, external size (width x height x depth) Unit body weigth * upon request Up to 99 minutes Low frequency Medium frequency See the section electro therapy and ultrasound See the section ultrasound See the section ultrasound See the section ultrasound 20 2 indipendent I / BF II B IPX0 39 x 13 x 32 cm 4.60 Kg up to 30 minutes 1 MHz and 3 MHz 15% 10% - 100% (10 100) Hz 2 W / cm 20% 3 W / cm 20% 25 100 50 1 Surge current Dynamic current Continue current Surge current Dynamic current Continue current up to 99 minutes Low frequency Medium frequency 25 total wave forms 100 mA 70 mA 50 mA 100 V 70 V 50V 25 100 50 100 20 2 indipendent

Made in Italy

Backlit LCD display, to view and check the operating parameters Stored protocols

65

Laser Therapy Introduction


Laser therapy is divided into contact therapy and scanning therapy, and for both types single diode and multi diode Lasers can be used. When it comes to contact therapy using single diode Lasers, handpieces are used that are placed directly on the skin. Trigger points or areas in which pain is located are stimulated, and this therapy required the physical presence of an operator. The most determining application parameters when using lasers are: power density (power released by density of the irradiated tissue area, which is measured in W/sq.cm. and is determined by dividing the laser output power by the size of the spot). The fluence rate is the most important parameter when it comes to determining the clinical effect of the lasers, as it measures the quantity of energy released per unit of area of irradiated tissue in J/sq.cm. and is calculated by multiplying the power density by the exposure time. Each protocol indicates the recommended fluence rate for each type of treatment. The operator adjusts the treatment time or frequency, according to the area to be treated and the power of the laser, in order to convey the fluence rate necessary for the treatment. ADVANTAGES OF LASER THERAPY Laser therapy is based on the photochemical and photobiological effects in the cells and tissue. The laser light stimulates the cells mitochondrion, and reinstates its energy and repairs it in the case of traumatic or degenerative situations, returning the cell itself to its normal state. Laser therapy is painless, free of any risks and is not invasive. The time required for treatment is shorter than that required when other therapies are used. EFFECTS OF THE LASER 1) Anti-inflammatory effect. 2) Effects on the peripheral nervous system (antalgic and regenerative effect). 3) Biostimulating effect, with regeneration of tissue. 4) Effect on micro circulation and blood vessels: the laser indices improvement of local micro circulation, which includes the relief of local spasms of the arteriolar and venular vessels (which occurs, for example, after trauma or inflammation), and brings about intensification of the blood flow in the nutritional capillaries. 5) Immunomodulating effect. 6) Enzyme photo activation effect. 7) Placebo effect. INDICATIONS FOR USING LASERS 1) Rheumatology 2) Orthopedics 3) Dermatology 4) Dentistry 5) Otolaryngology 6) Neurology 7) Laser acupuncture

ACCESSORIES

EL0028 el0029 el0030

1 diode - 25mw HANDPIECE 1 diode - 50mw HANDPIECE 1 diode - 100mmw HANDPIECE

el0031

3 DIODE - 75mw HANDPIECE

el0032 el0033

3 DIODE - 150mw HANDPIECE 3 DIODE - 300mw HANDPIECE

el0034 el0035 el0036

5 DIODE - 125mw HANDPIECE 5 DIODE - 250mw HANDPIECE 5 DIODE - 500mw HANDPIECE

el0037 el0038 el0039

8 DIODE - 200mw HANDPIECE 8 DIODES - 400mw HANDPIECE 8 DIODE - 800mw HANDPIECE

el0040
laser arm

el0042
l1 arm

Arm for 1 diode handpiece with possibility of fixing to trolley (code EL12003).

Pantograph arm for 1 diode handpiece. Free fixing..

el0041
laser arm

el0043
l3-5-8 arm

Arm for 3-5-8 diode handpiece with possibility of fixing to trolley (code EL12003).

Pantograph arm for 3-5-8 diode handpieces. Free fixing.

el12003
TROLLEY

el0016
CASE

Trolley with tabletop and possibility of fixing nonwheeled electromedical equipment and the arms.

el0001

PERSONAL SMART CARD

10 pcs pack to program the patients rehabilitation protocol, so as to facilitate and expedite the operating time of the equipment.

66

www.chinesport.com

Laser Therapy - PlusLine


el12061 fisiolaser ird
Laser therapy equipment with 1 output. Laser wavelength 905 nm.

Made in Italy

el12062 fisiolaser ird 2

Laser therapy unit with 2 independent outputs, with automatic treatment time setting according to the energy to be provided and the area selected, and an indication of the energy transmitted in relation to the treatment time and area.

ACCESSORIES SUPPLIED
Power cable Fuses Laser MLA 1 handpiece (25 mW) Laser protective eyewear Interlock (protective key) Smart card

el12061
1 2 x 315 A-T 1 2 1 1

el12062
1 2 x 6.3 A-T 1 2 1 1

Included Smart Card

ACCESSORIES el001
el0016
CASE

Personal smart card

el0036

5 DIODE - 500mw HANDPIECE

el0037 el0038 el0039 el0040


laser arm laser arm l1 arm

8 DIODE - 200mw HANDPIECE 8 DIODES - 400mw HANDPIECE 8 DIODE - 800mw HANDPIECE

EL0028 el0029 el0030 el0031 el0032 el0033 el0034 el0035

1 diode - 25mw HANDPIECE 1 diode - 50mw HANDPIECE 1 diode - 100mmw HANDPIECE 3 DIODE - 75mw HANDPIECE 3 DIODE - 150mw HANDPIECE 3 DIODE - 300mw HANDPIECE 5 DIODE - 125mw HANDPIECE 5 DIODE - 250mw HANDPIECE

el0041 el0042 el0043


l3-5-8 arm TROLLEY

el12003

1-diode handpiece

3-diode handpiece

5- or 8-diode handpiece

67

Laser Therapy - PlusLine


TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed from the mains: Double mains fuse protection: Interlock socket/Safety key (contacts normally closed) Backlit LCD display, to view and check the operating parameters Programmable treatment time Diode Laser wave length emission Laser classication according to EN 60825-1 Device class in according to the 93/42/CEE directive Electrical insulation / applied parts class in according to the UNI EN 60601-1 standard Degree of protection by the liquid access in according to the UNI EN 60601-1 standard EMP LEA Divergence DNRO (direct light) DNRO (scattered light) Sensor for detecting IR radiation of the external handpiece Programmable pulse frequency Pulse duration Automatic scanning Pointer Pulsed mode 230 V 115 V 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 15 VA 315 mA Rit. 5 x 20 mm 630 mA Rit. 5 x 20 mm 3 contact DIN socket Graphics 240 x 128 pixel up to 99 minutes 905 nm 3B 4 depends on the laser probes used II B I / BF IPX0 5032,06 J . m-2 77.1 mW (class limit 3B) 107 mrad 2.89 m 0.00 m on the front (200-10.000) Hz 100 nsec 5 frequencies per decade Solid-state Laser, 3mW @ 650nm (10 100 ) % 25 W Peak power for single diode 50 W 100 W 500 W Total peak power depends on handpiece-applicator (See accessories) Target pointing device in conformity with the UNI EN 60601-2-22 standard Light-drive device Target pointing device characteristics Light-drive color Light-drive representation on the impact point Laser-beam positioning 2 light-drive Led-diode red Spot with red as colour Always to the centre of the simmetry axis of 2 red spots manual emission Typology for emission of the treatment Fisiolaser IRD 2 Fisiolaser IRD automatic emission continuous emission Output channels Stored protocols Storable protocols on the smart-card Table container in plastic, external size (width x height x depth) Unit body weight Conditions for use Fisiolaser IRD 2 Fisiolaser IRD Room temperature Relative humidity Room temperature Conditions for stocking / transport * upon request Relative humidity Atmospheric pressure 2 independents 1 79 50 39 x 13 x 32 cm without probe-holders 2 indipendent I / BF (+10: +40) C (10: 80) % without condensation (+10: +40) C (10: 80) % without condensation (500: 1060) hPa

68

www.chinesport.com

Scanning Laser Therapy - PlusLine


Applying scanning laser therapy, using single or multi diode lasers, also makes it possible to treat larger areas that when contact therapy is applied, and to apply the therapy automatically, without the presence of an operator. The rule that applies to all forms of medical treatment applies to Laser treatment as well: the best results are obtained by therapists that have sound medical training, know how to listen to the patient, and have good intuitive skills.. ADVANTAGES TO USING SCANNING LASER THERAPY Scanning laser units run in automatic mode, as they do not require an operator to be present. Using a scanning laser unit makes it possible to treat larger areas that when a contact laser is used. Automatic setting of the treatment area. Scanning area adjustable up to 400 cm Possibility of connecting an external single / multidiode laser handpiece. ADVANTAGES OF DIODE LASERS More efficacious Long working life and simpler maintenance International standards classify the danger of Lasers in 6 classes: 1, 2, 3A, 3R, 3B, and 4 with an increasing degree of danger, according to the power supplied.
Included Smart Card

Made in Italy

EL12081 FISIOLASER SCAN 500

Trolley-mounted equipment for scanning laser therapy, power 500 mW

EL12079 FISIOLASER scan HP4

Trolley-mounted equipment for scanning laser therapy, power 4 W (2+2)

EL12080 FISIOLASER scan HP8

Trolley-mounted equipment for scanning laser therapy, power 8 mW

ACCESSORIES SUPPLIED
Power cable Fuses Laser protective eyewear Interlock (protective key) Emergency pushbutton Smart card

el12081
1 2 x 630 mA-T 2 1 0 1

el12079
1 2 x 1.6 A-T 2 1 1 1

el12080
1 2 x 1.6 A-T 2 1 1 1

ACCESSORIES el001
el0016
CASE

Personal smart card

el0036 el0037 el0038 el0039 el0040


laser arm laser arm l1 arm

5 DIODE - 500mw HANDPIECE 8 DIODE - 200mw HANDPIECE 8 DIODES - 400mw HANDPIECE 8 DIODE - 800mw HANDPIECE

EL0028 el0029 el0030 el0031 el0032 el0033 el0034 el0035

1 diode - 25mw HANDPIECE 1 diode - 50mw HANDPIECE 1 diode - 100mmw HANDPIECE 3 DIODE - 75mw HANDPIECE 3 DIODE - 150mw HANDPIECE 3 DIODE - 300mw HANDPIECE 5 DIODE - 125mw HANDPIECE 5 DIODE - 250mw HANDPIECE

el0041 el0042 el0043


l3-5-8 arm TROLLEY

el12003

69

Scanning Laser Therapy - PlusLine


TECHNICAL SPECIFICATIONS
Mains power supply: 500 Maximum power absorbed from the mains: HP4 HP8 500 Double fuse protection: HP4 HP8 Interlock socket/Safety key (contacts normally closed) Backlit LCD Display, to visualise and control operating parameters: Programmable treatment time: 500 Diode Laser wave length emission HP4 HP8 500 Laser classification according to EN 60825-1 HP4 HP8 Device class in according to the 93/42/CEE directive Electrical insulation / applied parts class in according to the UNI EN 60601-1 standard Degree of protection by the liquid access in according to the UNI EN 60601-1 standard Programmable pulse frequency X scanning amplitude Y scanning amplitude Area X scanning speed Y scanning speed Divergence 500 Number of diodes in the device HP4 HP8 500 DNRO (direct light) HP4 HP8 500 DNRO (scattered light) HP4 HP8 500 Power @ 200 Hz HP4 HP8 500 Power @ 10000 Hz HP4 HP8 Target pointing device characteristics Target pointing device in conformity with the UNI EN 60601-2-22 standard Light-drive device Light-drive color Light-drive representation on the impact point Laser-beam positioning 2 light-drive Led-diode red Spot with red as colour Always to the centre of the simmetry axis of 2 red spots 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 25VA 60VA 60VA 630 mA-T for 230Vac-supply, 1.6 A-T for 115Vac-supply 1.6 A-T for 230Vac-supply, 3.15 A-T for 115Vac-supply 3 contact DIN socket graphic 240 x 128 pixel up to 99 minutes 808 nm 940 nm 940 nm 3B 4 4 II B I / BF IPX0 ( 200 10000 ) Hz ( 1 20 ) cm @ 45cm approx. ( 1 20 ) cm @ 45cm approx. ( 1 400 ) cm @ 45cm approx. Adjustable in 5 steps Adjustable in 5 steps 20mrad 1 x 500mW 2 x 2W 1 x 4W 5m 53m in mono-diode version 25m in multi-diode version 75m in mono-diode version 3cm 20cm in mono-diode version 10cm in multi-diode version 41cm in mono-diode version 12.5mW 80 mW 160 mW 500mW 4000 mW 8000 mW

70

www.chinesport.com

Scanning Laser Therapy - PlusLine


500

Made in Italy
1.00 @ 808nm to 0.5m as distance 3.94 @ 940nm to 0.5m as distance in mono-diode version

Minimal optical density (goggles protection factor necessary at the minimal distance indicated)

HP4

3.40 @ 940nm to 1m as distance in mono-diode version 3.64 @ 940nm to 0.5m as distance in mono-diode version 4.24 @ 940nm to 0.5m as distance in mono-diode version 3.70 @ 940nm to 1m as distance in mono-diode version 2 independents Solid state laser, 3mW 650nm on the front 85 200 39 x H168 x 43cm 35 Kg (+10: +40) C (10: 80) % without condensation (+10: +40) C (10: 80) % without condensation (500: 1060) hPa

HP8

Output channels Pointer External probe (optional) sensor for detecting IR radiation Stored therapeutic suggestions Storable therapeutic suggestions Trolley container, external size (width x height x depth) Unit body weight Conditions for use Room temperature Relative humidity Room temperature Conditions for stocking / transport * upon request Relative humidity Atmospheric pressure

Mixed Scanning (rhomboidal)

Horizontal Scanning

Vertical Scanning

Horizontal and Vertical Scanning

71

High Power Laser Therapy - ExcellentLine


Powerful Thanks to the high power provided in its versions, deep layers of tissue can be stimulated, thereby facilitating quick, widespread cell regeneration. Deep tissue can be stimulated, which makes it possible to treat the innermost tissue and structures (such as the femur joint, for example) and chronic pathologies like arthritis. Effective Provides resolution of acute, chronic and degenerative inflammations, such as arthritis in the knee. Multi spot The machines automatically calculate the energy dosage (Fluence rate in Joules) provided according to the various types of application, on contact or via the 3 spacers available. Easy and safe to use The software installed can be used by all operators, user-friendly commands that are quick and easy to execute. Designed to guarantee the highest safety standards. Particular care has been taken in relation to the patient and the operator. The fields of application that can benefit from using high power laser therapy are: Sports traumatology General medicine and dermatology Arthro-rheumatic pathology Rehabilitation therapy
LUNGHEZZA DONDA - WAVELENGHT (nm)
200 300 400 500 600 700 810 900 980 1100 1200 1300 1400 10600

Included Smart Card

EL12086 fisiolaser excellent 8w


High power (8W) fibre optic laser therapy equipment.

el12087 fisiolaser excellent 12w


High power (12W) fibre optic laser therapy equipment. ACCESSORIES SUPPLIED
Laser protective eyewear Power cable Fuses Smart card

el12086
2 1 2 1

el12087
2 1 2 1

Epidermide Epidermis Derma Derma Ipoderma(Tessuto Adiposo) Hypoderm (Adipose tissue) Muscolo Muscle

Osso Bone

el12003
TROLLEY

el0016
CASE

Trolley with tabletop and possibility of fixing nonwheeled electromedical equipment and the arms.

el0001

PERSONAL SMART CARD

10 pcs pack to program the patients rehabilitation protocol, so as to facilitate and expedite the operating time of the equipment.

72

www.chinesport.com

High Power Laser Therapy - ExcellentLine


TECHNICAL SPECIFICATIONS - EL12086
Mains power supply: Maximum power absorbed by the net: Double fuse protection on the net, delayed type (T) 230 Vac 115 Vac*

Made in Italy

Max power LCD back-lit display Emission wavelength of the diode laser Laser classication DNRO (direct light) Divergence Impulse duration Emission Selectable percentage of emitted power Emission frequency Pulsed mode Classification according to the directive 93/42/CEE Emission Regulation Output channel Class of isolation / parts applied according to the rule EN 60601-1 Protection level from the entrance of liquids according to the rule EN 60601-1 Minimum optical density (protection factors of the glasses indicated the minimum distance required) Programmable treatment a contatto Spot areas available Protocols in memory Number of protocols that can be saved in the user memory Number of protocols that can be saved in the smart-card Table container External dimensions (Width * Height * Depth) Weight of the device body: Characteristics of the guide light Guide light device Power Wavelength Laser class DNRO (m) Divergence of the beam Target pointing device for the laser probe according to the rule UNI EN 60601-2-22 Representation of the guide light on the impact point Positioning of the laser beam Position1 Position 2 Position 3

230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 70 VA 630 mA-T - 5 x 20 mm 1,6 A-T - 5 x 20 mm 8W 20% graphic 320 x 340 pixel TOUCHSCREEN 940 nm IV 1,721 440mrad programmabile CONTINUE 0% - 100% 100 Hz 10000 Hz 10% - 100% IIB CONTINUE 10% - 100% 1 sso I / BF IPX0 1.02@940nm to 0.5m as distance 1-60 min 0.040 cm 0.186 cm 0.484 cm 0.861 cm 32 200 200 39x13x32 cm 4,65 Kg Diodo laser 0,3 mW 650nm 2 0,002 440mrad Light guide in the optical ber Circular ring Centre of the ring always

Conditions for use Conditions for stocking / transport


* upon request

Room temperature Relative humidity Room temperature Relative humidity Atmospheric pressure

(+10: +40) C (10: 80) % without condensation (- 40: +70) C (10: 100) % without condensation (500: 1060) hPa

73

High Power Laser Therapy - ExcellentLine


TECHNICAL SPECIFICATIONS - EL12087
Mains power supply: Maximum power absorbed by the net: Double fuse protection: Interlock socket/Safety key (contacts normally closed) Backlit LCD Display, to visualise and control operating parameters: Emission wavelength of the diode laser Laser power delivered from the sources Max power 12W 20% Laser classication Numerical aperture of the sources DNRO (direct light) DNRO (diffuse light) Divergence Emission frequency Laser power delivered by sources Command for the implementation of the treatment Minimum optical density (protection factors of the glasses indicated the minimum distance required) Pulsed mode Emission type Spot 1 Spot 2 Spot 3 Spot 4 Spot 1 Spot 2 Spot 3 Spot 4 Spot 1 Spot 2 Spot 3 Spot 4 808 nm 980 nm 808 nm 980nm 230 Vac 115 Vac* 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 75 VA 1A-T - 5 x 20 mm 2 A-T - 5 x 20 mm 3 contact DIN socket graphic 320 x 340 pixel TOUCH SCREEN 808 nm 980nm 4W 8W 12W 20% IV 0.22 0.22 2.986 m min. 0.562 m min 440mrad (100-10000) Hz 120mW @ 100 Hz 12W @ 10000 Hz Pedal 1.55 (distance 0,5m) 0.95 (distance 1m) 10% - 100% Manual mode Mode at point 6 mm 13 mm 21 mm 28 mm 2.24 mm 4.86 mm 7.85 mm 10.47 mm ~ 4 mm ~ 18.6 mm ~ 48.4 mm ~ 86.1 mm IIB I / BF IPX0 1 1-99 min 32 depending on the number of characters used to compile the therapeutic suggestion depending on the number of characters used to compile the therapeutic suggestion Table conguration 39x13x32 cm 4,65 Kg

Distance of the laser beam from the skin of the patient treated

Spot size incident on the skin of the patient treated

Area of the spot incident on the skin of the patient treated

Classification according to the directive 93/42/CEE Class of isolation / parts applied according to the rule EN 60601-1 Protection level from the entrance of liquids according to the rule EN 60601-1 Output channel Programmable treatment time Protocols in memory Number of protocols that can be saved in the user memory Number of protocols that can be saved in the smart card Patients cards saved in the user memory Patients cards saved in the smart card Type of the container Table container external dimensions (Width * Height * Depth) Weight of the device body:

Conditions for use Conditions for stocking / transport


* upon request

Room temperature Relative humidity Room temperature Relative humidity Atmospheric pressure

(+10: +40) C (10: 80) % without condensation (+10: +40) C (10: 100) % without condensation (500: 1060) hPa

74

www.chinesport.com

Magneto Therapy Introduction


Magneto therapy equipment generates a low frequency magnetic field (adjustable between 1 and 100 Hz) with an intensity up to 100 Gauss per individual output, which generates beneficial effects, especially in regenerating tissue and bone tissue. PRINCIPAL INDICATIONS Recent fractures that are slow to consolidate. The magnetic fields stimulate osteogenetic activity at the fracture fissure, speeding up consolidation times for fractures in a very high percentage of cases. The process of healing bone discontinuity occurs by inducing a piezo-electrical effect in the connecting structures, and improving local circulatory conditions. Pseudarthrosis It has been shown that magnetic fields are effective in treating pseudarthrosis. Sudecks disease and Osteoporosis Magneto therapy has been found to be effective in 80% of cases of Sudecks disease and 70% of osteoporosis cases. Inflammatory and degenerative arthropathy Magneto therapy is indicated for treating both inflammatory and degenerative type arthropathy. Positive results have been achieved with rheumatoid arthritis localised in the hands and knees, in spondylitis ankylopoietica, gonarthrosis, and lumbar arthrosis. Obliterating arteriopathy Magnatic fields are effective in vascular pathologies, thanks to their effect on blood flow and micro circulation. Decubitus wounds The biostimulating effect justifies the use of magneto therapy in this pathology. Very long treatments are required. Psoriasis Psoriasis responds positively to this therapy in 60% of cases. OTHER APPLICATIONS Skin wounds / ulcers Infections/Inflammations Muscle spasms / circulatory alterations Arthrosis, Rheumatism Stimulation of the hormonal and lymphatic system

Made in Italy

ACCESSORIES
el0045
solenoid 22

Shielded solenoid (cm) 60 x 22.

el0046

solenoid 36

Shielded solenoid (cm) 60 x 36.

el0044

TREATMENT COUCH

A therapy couch (cm) 86 x 200 x 70 h weight 40 kg.

el0048

shielded Solenoid 30

el0049

Portable 30 cm cylinder for treating lower and upper limbs. Fitted with feet.

shielded Solenoid 50

el0047

Portable 50 cm cylinder for Pair of applicators for treating lower and upper limbs. localised treatment. Side Fitted with feet. by side (to treat large areas), counterposed (to concentrate magnetic induction in a confined area) cm 16 x 10 x 4

Contact applicators

Magnetic Field Concentrator

MFC

el0016
CASE

el12003
TROLLEY

Trolley with tabletop and possibility of fixing nonwheeled electromedical equipment and the arms.

Magnetic Field Concentrator is an exclusively patented innovation who drastically reduces the electromagnetic contamination generated by solenoids for magnetic therapy an appreciable improvement in both quality and safety in the workplace. The instrumental measurements showed that using the MFC patent the electromagnetic pollution of the surranding space is reduced by more than 85%.

el0001

PERSONAL SMART CARD

10 pcs pack to program the patients rehabilitation protocol, so as to facilitate and expedite the operating time of the equipment.

75

Magneto Therapy - PlusLine


el12064 magneto 2
Generator for magneto therapy assembled in a table-top container with two outputs: Independent, with the possibility of activating the outputs in the following combinations: 1, 2 Independent, or 1+2 simultaneously (ideal for total body treatments that call for simultaneous piloting of 2 solenoids).

el12065 magneto 4

Generator for magneto therapy assembled in a table-top container with four outputs: Independent, with the possibility of activating the outputs in the following combinations: 1 - 3 , or 2 - 4 Independent, or 1+2 and 3+4 simultaneously (ideal for total body treatments that call for simultaneous piloting of 4 solenoids).

Included Smart Card

ACCESSORIES SUPPLIED
Power cable Fuses Ring magnet (only for test) Smart card

el12064 1 2 x 3.15 A-T 1 1

el12065 1 2 x 6.3 A-T 1 1

ACCESSORIES el0001 PERSONAL SMART CARD el0016 CARRYING CASE el0044 TREATMENT COUCH el0045 solenoid 22 el0046 solenoid 36

el0047 Contact applicators el0048 shielded Solenoid 30 el0049 shielded Solenoid 50 el12003 TROLLEY

76

www.chinesport.com

Made in Italy

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed Magneto 4 Magneto 2 Magneto 4 Double fuse protection Magneto 2 Backlit LCD display to view and check the operating parameters Programmable treatment time Duty Cycle adjustable Programmable treatment frequency Electrical insulation class / applied parts in compliance with the UNI EN 60601-1 standard Device class in compliance with the 93/42/CEE directive Degree of protection against the input of liquids according to the UNI EN 60601-1 standard Maximum induction Magneto 4 Output channels Magneto 2 Stored protocols Storable protocols in the smart-card Storable protocols in the user memory Plastic desktop container , external size (width x height x depth) Unit body weight 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 900 VA 450 VA 6.3 A Rit. - 5 x 20 mm for 230Vac supply, 10 A Rit. - 5 x 20 mm for 115Vac supply 3.15 A Rit. - 5 x 20 mm for 230Vac supply, 6.3 A Rit. - 5 x 20 mm for 230Vac supply graphic 320 x 240 pixel up to 60 minutes (10100) % (1100) Hz I / BF II A IPX0 100 Gauss 20% 4 , 2 by 2 independents 2 independents 85 200 200 39 x 13 x 32 cm 3,9 Kg

Conditions for use Conditions for stocking / transport


* upon request

Room temperature Relative humidity Room temperature Relative humidity Atmospheric pressure

(+10: +40) C (10: 80) % without condensation (- 40: +70) C (10: 100) % without condensation (500: 1060) hPa

77

Radar Therapy - PlusLine


Radar Therapy is part of the range of Heat Therapies and uses electromagnetic waves to transmit heat into tissue in depth. The therapeutic effects of radar therapy are muscular heating, and an analgesic and trophic effect. Radar therapy is indicated in cases of muscular contraction, arthrosis, post-traumatic algia, tendinitis, etc.. THERAPEUTIC ACTIONS 1) Pain reduction 2) Improvement of collagen extensibility 3) Reduction of joint rigidity 4) Reduction of oedema and inflammatory exudates 5) Increase in blood flow accessoriES

el12060 microradar puls


ACCESSORIES SUPPLIED
Power cable Fuses 6,3 A-T Pantograph arm High frequency output cable Circular antenna Smart card

Radar therapy equipment with continuous and pulsed operating modes.

1 2 1 1 1 1 Included Smart Card

el0001 el0027 three-dimensional antenna


Wraparound antenna, cm 50x20x18h

PERSONAL SMART CARD

el0026 rectangular antenna


Long field antenna, cm 47x12x7h.

10 pcs pack to program the patients rehabilitation protocol, so as to facilitate and expedite the operating time of the equipment.

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed 230 Vac 115 Vac Backlit LCD display to view and check the operating parameters Programmable treatment time Emission frequency Device class in according to the 93/42/CEE directive Electrical insulation / applied parts class in according to the UNI EN 60601-1 standard Degree of protection by the liquid access in according to the UNI EN 60601-1 standard Double fuse protection Operation Continuous power peak 50 Ohms Pulsed power peak 50 Ohms Stored protocols Storable protocols in the user memory Storable protocols in the smart-card Metal trolley container, external size (width x height x depth) 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 600 VA 6.3 A-T - 5 x 20 mm 10 A-T - 5 x 20 mm graphics 320 x 240 pixels up to 30 minutes 2450 MHz II B I / BF IPX0 Continuous 100% Pulsed 10% 90% 250 W 1600 W 100 200 200 39 x 112 x 43 cm with arm and antenna not mounted 65 x 177 x 43 cm with arm and antenna mounted 34 Kg with arm and antenna not mounted 38,5 Kg with arm and antenna mounted (+10: +40) C (10: 80) % without condensation (+10 +40) C (10 80) % without condensation (500 1060) hPa

Unit body weight Conditions for use Conditions for stocking / transport * upon request Room temperature Relative humidity Room temperature Relative humidity Atmospheric pressure

78

www.chinesport.com

Pressure Therapy - PlusLine


Pressure therapy is a therapeutic massage that helps counteract oedema and improve circulation by activating pressure. This pressure is applied sequentially by treating lower limbs with oedema, water retention, and circulatory problems. The pressure therapy acts on venous and lymphatic circulation, making it more efficient and as a result improving aesthetic blemishes such as cellulite, water retention, etc. THERAPEUTIC INDICATIONS Circulatory insufficiency Lymphatic stasis Hydro-lypo-distrophy (cellulite) Lymphedema Reactive skin fibrosis Hard oedema Surgery after care Hypotonia accessorY

Made in Italy

Included Smart Card

el12066 aRtipress
el0067 upper limb kit
7-sector armband.

ACCESSORIES SUPPLIED
Power cable Fuses 1,6 A-T Smart card 1 2 1

Pressure therapy equipment with 9 independent sectors.

el0001 PERSONAL SMART CARD

10 pcs pack to program the patients rehabilitation protocol, so as to facilitate and expedite the operating time of the equipment.

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed 230 Vac 115 Vac Backlit LCD display to view and check the operating parameters Programmable treatment time Number of pneumatic sectors (output) Air capacity of the compressor Compressor power Maximum pressure delivered by the compressor Maximum current absorbed by the compressor Independent pressure and time adjustment for each sector Device class in according to the 93/42/CEE directive Electrical insulation / applied parts class in according to the UNI EN 60601-1 standard Degree of protection by the liquid access in according to the UNI EN 60601-1 standard Maximum pressure Stored protocols Storable protocols in the user memory Storable protocols in the smart-card Metal trolley container , external size (width x height x depth) Unit body weight Room temperature Conditions for use Relative humidity Room temperature Relative humidity Conditions for stocking / transport Atmospheric pressure Double fuse protection * upon request 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 150 VA 1,6 A Rit. 5 x 20 mm 3.15 A Rit. 5 x 20 mm graphics 320 x 240 pixels up to 60 minutes 9 25 lt/min 106 VA 3.5 atm 0.45 A I / BF II A IPX0 150 mm Hg 21 100 100 39x 13 x 32 cm 30 Kg (+10: +40) C (10: 80) % without condensation (+10 +40) C (10 80) % without condensation (500 1060) hPa

79

Shock Wave - ExcellentLine


Shock waves are sound waves that convey high energy, transmitted through the surface of the skin and diffused in the body radially, over the painful area. This is a (ballistic) radial shock wave, since the shock wave is generated using a special hand unit shaped like a pistol, the barrel of which is closed at the end by a metal cap, against which a steel projectile is launched using compressed air (up to a pressure of 5 bar). This generates s shock wave that spreads out radially in the skin and first tissue layer below the skin, or in a focussed manner (depending on the transmitter used). The body responds by increasing metabolic activity in the application area, facilitating the reduction of inflammation caused by a painkilling action brought about by local releasing of endorphine, thereby stimulating and speeding up the healing process. The extent of penetration depth varies from 4 to 7 cm. Fields of application: Orthopaedics Rehabilitation Sport medicine Plastic surgery IndicaTIONS: The shock wave method is the preferred treatment for chronic insertion tendonopathy, characterised by poor vascularisation of the bone-tendon joint, where physiotherapy treatment (infiltration and laser therapy) has proved ineffective. The principal pathologies for which shock waves are used include: Elbow - epicondylitis, epitrochleitis Shoulder - insertional tendonopathies, impingement Knee - Tendonopathies of the kneecap and anserine bursa Pubes - Tendonopathies of the adductors (pubalgie) Ankle - Achilles tendonopathies, calcaneal apophysis..

Included Smart Card

el12088 shock wave

Trolley-mounted equipment that provides high energy transportation of sound wave energy transmitted through the skins surface and diffused radially in the body in the painful area. ACCESSORIES SUPPLIED
Applicator Multi focussed 9 mm transmitter Focussed 15 mm transmitter Multi focussed 15 mm transmitter Gel 260 ml Interchangeable kit Display Pointer Smart card 1 1 1 1 1 1 1 1

80

www.chinesport.com

Shock Wave - ExcellentLine

Made in Italy

TECHNICAL SPECIFICATIONS
Mains power supply: Maximum power absorbed 230 Vac 115 Vac Backlit LCD display to view and check the operating parameters Heads dispensing Double fuse protection Shock emission modes Burst emission typology Pressure intensities allowed Shock emission frequency Treatment period Operation Classification according to the directive 93/42/CEE Insulation class / parts applied according to EN 60601-1 Protection degree from liquids according to EN 60601-1 Output channels Stored protocols Storable protocols on the user memory Storable protocols on the smart-card Clients forms that can be stored on the user memory Clients forms that can be stored on the smart-card External dimensions (large x high x deep): Weight Room temperature Conditions for use Relative humidity Room temperature Relative humidity Conditions for stocking / transport Atmospheric pressure * upon request 230 Vac, 50-60Hz, 10% 115 Vac, 50-60Hz, 10% * 80 VA 2 A Rit. - 5 x 20 mm 4 A Rit. - 5 x 20 mm graphics 320 x 340 pixels TOUCH SCREEN 3 Single Continues Burst (1-100) impulse of burst (10-2000) msec pause between impulse of burst (1.5 - 5) bar a step di 0.1 bar ( 1 20) Hz a step di 1 Hz (0-10000) blows Steady Voltage Steady Current II B I / BF IPX0 1 31 250 250 Depending on the number of characters used to compile the card 39x112x43 cm 31 Kg (+10: +40) C (10: 80) % without condensation (-40 +70) C (10 100) % without condensation (500 1060) hPa

81

Resistive-Capacitive Energy Transmission and an Integrated Transdermal Transport.


THERAPEUTIC INDICATIONS: Muscular injuries Joint capsulitis Distortions Cervicalia Bone and ligament trauma Tendon injuries and bursitis Lumbalgia and ischialgia Myositis Arthrosis processes Rehabilitation programmes
BIOLOGICAL EFFECTS OF THE TREATMENT Improvement of arterial flows, with an increase in the quantity of nutritive substances and oxygen Increase in metabolism due to these factors and due to an internal rise in temperature (vant Hoffs law) Increase in endocellular energy transformation (ADP into ATP) Improved membrane balance for all cells in the treated area (adipocytes, fibroblasts, etc.) Repolarisation of the cell
(from pathologies -40Mv to physiologies -70Mv)
Certificazione richiesta dalla Comunit Europea e riconosciuta a livello Internazionale

Passage of the extra-cellular matrix from a (pathological) gel state gel state to a (physiological) sol state Improvement of venous and lymphatic flow with more efficient expulsion of toxins and catabolites Potentiation and synergy with active ingredients to be diffused in the dermis and hypodermis, with evident application advantages compared to taking intramuscularly

TECHNICAL specifications
Working frequency Manual modules Power supply Max input power Passive plate area Capacitive electrode diameter Resistive electrode diameter Mini and standard Roll-on Electrical safety CEE 93/42 Class D 0.8 MHz - 1 MHz - 1.2 MHz 400 - 320 Vrms - 130 Wrms 230V - 50/60 Hz 10% 750W 240 cm2 cm 3.3 - 5.3 - 6.5 cm 3,3 - 5,3 - 6,5 cm 4 e 8 Class I II B

Patented Roll-on hand piece


The transfer of capacitive and resistive energy is associated with the diffusion of an active ingredient best suited to the pathology (and where prescribed by the physician), where applicable.
Absorption rejected because the skin pore is closed Absorption rejected because the skin pore is closed

Diffusion because the skin pore is open

82

www.chinesport.com

Made in Italy

EL0151 tCARE

Electro medical device complete with an upper storage surface for a wide range of applied parts (see coded list). This new device, unlike the Tecar and Endotherapy electro-medical devices, allows the physiotherapist to use simultaneously two treatment methods, combining the resistive/capacitive energy transfer and the diffusion of the active agent (where prescribed by the physician), with a hand piece called ROLL-ON (patented). Moreover the device features: Less than 50% of electromagnetic leakages in the work environment, resulting in a benefit for both the patient and the medical operator. Absence of dielectric arcs when removing the hand piece Roll-On. Continuous therapist monitoring of the energy absorbed by the patient, and possibility of regulating the frequency according to the absorption, also optimising diffusion of the active agents. The possibility of dealing incisively, completely, and multi-dimensionally with various musculoskeletal affections at an acute stage (characterised by extensive pain, low tolerance to contact, manipulation and traditional therapeutical methods in general), due to the combining of energy transfer with transdermal diffusion of any active agent. Dimensions: (cm) 61 x 50 x 95h - Weight: 30 kg
PLEASE NOTE The supply of this equipment includes a technical-practical course run by qualified personnel.

accessories SUPPLIED

These are shown to provide for any subsequent requests for spare parts.

el0147

MINI CAPACITIVE ROLL-ON

el0113

CAPACITIVE ROLL-ON

el0129

RESISTIVE ROLL-ON

To treat small anatomical areas

el0114 CAPACITIVE ROLL-ON el0116 6.5 CM CAPACITIVE ELECTRODE el0117 5.3 CM CAPACITIVE ELECTRODE el0118 3.3 CM CAPACITIVE ELECTRODE

el0115 RESISTIVE ROLL-ON el0119 6.5 CM RESISTIVE ELECTRODE el0120 5.3 CM RESISTIVE ELECTRODE el0121 3.3 CM RESISTIVE ELECTRODE

el0122 PASSIVE PLATE

el0123 3 ELASTIC BANDS


(cm 40-60-80)

el0148 DISPENSER WITH CAP el0128 BALL CAP


Packs in envelope: cap and container, 12 pcs each.

Disposable. 100 piece pack

el0149 mini dispenser

Packed in separate packets: containers -ball cap and cap, 100 pcs each.

el0125

ROLL-ON LUBRICATION CREAM

el0124

ROLL-ON handpieces not supplied, but available as spare parts, on request.

1000 ml tub

ROLL-ON LUBRICATION CREAM

el0155 CAPACITIVE
ROLL-ON

el0156 RESISTIVE
ROLL-ON

Two 500 ml packs.

83

Thermotherapy

el0070 special lamp

IR- and UV-ray therapy lamp with wheeled height-adjustable stand. Positioning by swivel arm. 500W power. CEI 62,39

el0073 sanisol bs

el0071 calor lamp

Same features as lamp (code EL0070), but for use with IR rays only. 400W power.

High-power light therapy lamp for professional use, with wheeled height-adjustable stand and tilting arm. (UV 550W-IR 950W). Reflector 32 cm. Max height: 200 cm. CE 93/42.

el0072 professional

Professional lamp for UV - and IR-ray treatments with wheeled height-adjustable stand and castors. 1000W power. CEI 62,39

EL0157

INFRA LAMP 750 Infrared therapy floor lamp with three 250W bulbs. You can switch on/off any one independently of the other two. Mechanical timer for treatments up to 15 minutes. Conforms to EC 93/42.
TECHNICAL specifications
Power supply Rated power Fuses Lamp holder dimensions Adjustable height Weight 230 V, 50 Hz. 750 W 6.3 A 55x15x21 cm from 82 to 152 cm 14 kg

el0077 sunlamp 70 uvb

Professional lamp for UVB narrow band phototherapy, emission peak at 311 nm. Stand with height-adjustable braking wheels. Automatic switching off by timer after max. 15 min. Power 4x20W. Actual lamp dimension 31x57 cm Supply of 2 pairs of protective eyewear. CE 93/42

84

www.chinesport.com